Development of high-speed video cameras
NASA Astrophysics Data System (ADS)
Etoh, Takeharu G.; Takehara, Kohsei; Okinaka, Tomoo; Takano, Yasuhide; Ruckelshausen, Arno; Poggemann, Dirk
2001-04-01
Presented in this paper is an outline of the R and D activities on high-speed video cameras, which have been done in Kinki University since more than ten years ago, and are currently proceeded as an international cooperative project with University of Applied Sciences Osnabruck and other organizations. Extensive marketing researches have been done, (1) on user's requirements on high-speed multi-framing and video cameras by questionnaires and hearings, and (2) on current availability of the cameras of this sort by search of journals and websites. Both of them support necessity of development of a high-speed video camera of more than 1 million fps. A video camera of 4,500 fps with parallel readout was developed in 1991. A video camera with triple sensors was developed in 1996. The sensor is the same one as developed for the previous camera. The frame rate is 50 million fps for triple-framing and 4,500 fps for triple-light-wave framing, including color image capturing. Idea on a video camera of 1 million fps with an ISIS, In-situ Storage Image Sensor, was proposed in 1993 at first, and has been continuously improved. A test sensor was developed in early 2000, and successfully captured images at 62,500 fps. Currently, design of a prototype ISIS is going on, and, hopefully, will be fabricated in near future. Epoch-making cameras in history of development of high-speed video cameras by other persons are also briefly reviewed.
High-Speed Schlieren Movies of Decelerators at Supersonic Speeds
NASA Technical Reports Server (NTRS)
1960-01-01
Tests were conducted on several types of porous parachutes, a paraglider, and a simulated retrorocket. Mach numbers ranged from 1.8-3.0, porosity from 20-80 percent, and camera speeds from 1680-3000 feet per second (fps) in trials with porous parachutes. Trials of reefed parachutes were conducted at Mach number 2.0 and reefing of 12-33 percent at camera speeds of 600 fps. A flexible parachute with an inflatable ring in the periphery of the canopy was tested at Reynolds number 750,000 per foot, Mach number 2.85, porosity of 28 percent, and camera speed of 36oo fps. A vortex-ring parachute was tested at Mach number 2.2 and camera speed of 3000 fps. The paraglider, with a sweepback of 45 degrees at an angle of attack of 45 degrees was tested at Mach number 2.65, drag coefficient of 0.200, and lift coefficient of 0.278 at a camera speed of 600 fps. A cold air jet exhausting upstream from the center of a bluff body was used to simulate a retrorocket. The free-stream Mach number was 2.0, free-stream dynamic pressure was 620 lb/sq ft, jet-exit static pressure ratio was 10.9, and camera speed was 600 fps.
Evaluating video digitizer errors
NASA Astrophysics Data System (ADS)
Peterson, C.
2016-01-01
Analog output video cameras remain popular for recording meteor data. Although these cameras uniformly employ electronic detectors with fixed pixel arrays, the digitization process requires resampling the horizontal lines as they are output in order to reconstruct the pixel data, usually resulting in a new data array of different horizontal dimensions than the native sensor. Pixel timing is not provided by the camera, and must be reconstructed based on line sync information embedded in the analog video signal. Using a technique based on hot pixels, I present evidence that jitter, sync detection, and other timing errors introduce both position and intensity errors which are not present in cameras which internally digitize their sensors and output the digital data directly.
NASA Astrophysics Data System (ADS)
Yonai, J.; Arai, T.; Hayashida, T.; Ohtake, H.; Namiki, J.; Yoshida, T.; Etoh, T. Goji
2012-03-01
We have developed an ultrahigh-speed CCD camera that can capture instantaneous phenomena not visible to the human eye and impossible to capture with a regular video camera. The ultrahigh-speed CCD was specially constructed so that the CCD memory between the photodiode and the vertical transfer path of each pixel can store 144 frames each. For every one-frame shot, the electric charges generated from the photodiodes are transferred in one step to the memory of all the parallel pixels, making ultrahigh-speed shooting possible. Earlier, we experimentally manufactured a 1M-fps ultrahigh-speed camera and tested it for broadcasting applications. Through those tests, we learned that there are cases that require shooting speeds (frame rate) of more than 1M fps; hence we aimed to develop a new ultrahigh-speed camera that will enable much faster shooting speeds than what is currently possible. Since shooting at speeds of more than 200,000 fps results in decreased image quality and abrupt heating of the image sensor and drive circuit board, faster speeds cannot be achieved merely by increasing the drive frequency. We therefore had to improve the image sensor wiring layout and the driving method to develop a new 2M-fps, 300k-pixel ultrahigh-speed single-chip color camera for broadcasting purposes.
Multiple Sensor Camera for Enhanced Video Capturing
NASA Astrophysics Data System (ADS)
Nagahara, Hajime; Kanki, Yoshinori; Iwai, Yoshio; Yachida, Masahiko
A resolution of camera has been drastically improved under a current request for high-quality digital images. For example, digital still camera has several mega pixels. Although a video camera has the higher frame-rate, the resolution of a video camera is lower than that of still camera. Thus, the high-resolution is incompatible with the high frame rate of ordinary cameras in market. It is difficult to solve this problem by a single sensor, since it comes from physical limitation of the pixel transfer rate. In this paper, we propose a multi-sensor camera for capturing a resolution and frame-rate enhanced video. Common multi-CCDs camera, such as 3CCD color camera, has same CCD for capturing different spectral information. Our approach is to use different spatio-temporal resolution sensors in a single camera cabinet for capturing higher resolution and frame-rate information separately. We build a prototype camera which can capture high-resolution (2588×1958 pixels, 3.75 fps) and high frame-rate (500×500, 90 fps) videos. We also proposed the calibration method for the camera. As one of the application of the camera, we demonstrate an enhanced video (2128×1952 pixels, 90 fps) generated from the captured videos for showing the utility of the camera.
Web Camera Based Eye Tracking to Assess Visual Memory on a Visual Paired Comparison Task.
Bott, Nicholas T; Lange, Alex; Rentz, Dorene; Buffalo, Elizabeth; Clopton, Paul; Zola, Stuart
2017-01-01
Background: Web cameras are increasingly part of the standard hardware of most smart devices. Eye movements can often provide a noninvasive "window on the brain," and the recording of eye movements using web cameras is a burgeoning area of research. Objective: This study investigated a novel methodology for administering a visual paired comparison (VPC) decisional task using a web camera.To further assess this method, we examined the correlation between a standard eye-tracking camera automated scoring procedure [obtaining images at 60 frames per second (FPS)] and a manually scored procedure using a built-in laptop web camera (obtaining images at 3 FPS). Methods: This was an observational study of 54 clinically normal older adults.Subjects completed three in-clinic visits with simultaneous recording of eye movements on a VPC decision task by a standard eye tracker camera and a built-in laptop-based web camera. Inter-rater reliability was analyzed using Siegel and Castellan's kappa formula. Pearson correlations were used to investigate the correlation between VPC performance using a standard eye tracker camera and a built-in web camera. Results: Strong associations were observed on VPC mean novelty preference score between the 60 FPS eye tracker and 3 FPS built-in web camera at each of the three visits ( r = 0.88-0.92). Inter-rater agreement of web camera scoring at each time point was high (κ = 0.81-0.88). There were strong relationships on VPC mean novelty preference score between 10, 5, and 3 FPS training sets ( r = 0.88-0.94). Significantly fewer data quality issues were encountered using the built-in web camera. Conclusions: Human scoring of a VPC decisional task using a built-in laptop web camera correlated strongly with automated scoring of the same task using a standard high frame rate eye tracker camera.While this method is not suitable for eye tracking paradigms requiring the collection and analysis of fine-grained metrics, such as fixation points, built-in web cameras are a standard feature of most smart devices (e.g., laptops, tablets, smart phones) and can be effectively employed to track eye movements on decisional tasks with high accuracy and minimal cost.
High-speed optical 3D sensing and its applications
NASA Astrophysics Data System (ADS)
Watanabe, Yoshihiro
2016-12-01
This paper reviews high-speed optical 3D sensing technologies for obtaining the 3D shape of a target using a camera. The focusing speed is from 100 to 1000 fps, exceeding normal camera frame rates, which are typically 30 fps. In particular, contactless, active, and real-time systems are introduced. Also, three example applications of this type of sensing technology are introduced, including surface reconstruction from time-sequential depth images, high-speed 3D user interaction, and high-speed digital archiving.
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-01-01
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera. PMID:26959023
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-03-04
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera.
Serial-to-parallel color-TV converter
NASA Technical Reports Server (NTRS)
Doak, T. W.; Merwin, R. B.; Zuckswert, S. E.; Sepper, W.
1976-01-01
Solid analog-to-digital converter eliminates flicker and problems with time base stability and gain variation in sequential color TV cameras. Device includes 3-bit delta modulator; two-field memory; timing, switching, and sync network; and three 3-bit delta demodulators
Synchronizing A Stroboscope With A Video Camera
NASA Technical Reports Server (NTRS)
Rhodes, David B.; Franke, John M.; Jones, Stephen B.; Dismond, Harriet R.
1993-01-01
Circuit synchronizes flash of light from stroboscope with frame and field periods of video camera. Sync stripper sends vertical-synchronization signal to delay generator, which generates trigger signal. Flashlamp power supply accepts delayed trigger signal and sends pulse of power to flash lamp. Designed for use in making short-exposure images that "freeze" flow in wind tunnel. Also used for making longer-exposure images obtained by use of continuous intense illumination.
NASA Astrophysics Data System (ADS)
Kittle, David S.; Patil, Chirag G.; Mamelak, Adam; Hansen, Stacey; Perry, Jeff; Ishak, Laura; Black, Keith L.; Butte, Pramod V.
2016-03-01
Current surgical microscopes are limited in sensitivity for NIR fluorescence. Recent developments in tumor markers attached with NIR dyes require newer, more sensitive imaging systems with high resolution to guide surgical resection. We report on a small, single camera solution enabling advanced image processing opportunities previously unavailable for ultra-high sensitivity imaging of these agents. The system captures both visible reflectance and NIR fluorescence at 300 fps while displaying full HD resolution video at 60 fps. The camera head has been designed to easily mount onto the Zeiss Pentero microscope head for seamless integration into surgical procedures.
Andreozzi, Jacqueline M; Zhang, Rongxiao; Glaser, Adam K; Jarvis, Lesley A; Pogue, Brian W; Gladstone, David J
2015-02-01
To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.
An ultrahigh-speed color video camera operating at 1,000,000 fps with 288 frame memories
NASA Astrophysics Data System (ADS)
Kitamura, K.; Arai, T.; Yonai, J.; Hayashida, T.; Kurita, T.; Maruyama, H.; Namiki, J.; Yanagi, T.; Yoshida, T.; van Kuijk, H.; Bosiers, Jan T.; Saita, A.; Kanayama, S.; Hatade, K.; Kitagawa, S.; Etoh, T. Goji
2008-11-01
We developed an ultrahigh-speed color video camera that operates at 1,000,000 fps (frames per second) and had capacity to store 288 frame memories. In 2005, we developed an ultrahigh-speed, high-sensitivity portable color camera with a 300,000-pixel single CCD (ISIS-V4: In-situ Storage Image Sensor, Version 4). Its ultrahigh-speed shooting capability of 1,000,000 fps was made possible by directly connecting CCD storages, which record video images, to the photodiodes of individual pixels. The number of consecutive frames was 144. However, longer capture times were demanded when the camera was used during imaging experiments and for some television programs. To increase ultrahigh-speed capture times, we used a beam splitter and two ultrahigh-speed 300,000-pixel CCDs. The beam splitter was placed behind the pick up lens. One CCD was located at each of the two outputs of the beam splitter. The CCD driving unit was developed to separately drive two CCDs, and the recording period of the two CCDs was sequentially switched. This increased the recording capacity to 288 images, an increase of a factor of two over that of conventional ultrahigh-speed camera. A problem with the camera was that the incident light on each CCD was reduced by a factor of two by using the beam splitter. To improve the light sensitivity, we developed a microlens array for use with the ultrahigh-speed CCDs. We simulated the operation of the microlens array in order to optimize its shape and then fabricated it using stamping technology. Using this microlens increased the light sensitivity of the CCDs by an approximate factor of two. By using a beam splitter in conjunction with the microlens array, it was possible to make an ultrahigh-speed color video camera that has 288 frame memories but without decreasing the camera's light sensitivity.
Detection of pointing errors with CMOS-based camera in intersatellite optical communications
NASA Astrophysics Data System (ADS)
Yu, Si-yuan; Ma, Jing; Tan, Li-ying
2005-01-01
For very high data rates, intersatellite optical communications hold a potential performance edge over microwave communications. Acquisition and Tracking problem is critical because of the narrow transmit beam. A single array detector in some systems performs both spatial acquisition and tracking functions to detect pointing errors, so both wide field of view and high update rate is required. The past systems tend to employ CCD-based camera with complex readout arrangements, but the additional complexity reduces the applicability of the array based tracking concept. With the development of CMOS array, CMOS-based cameras can employ the single array detector concept. The area of interest feature of the CMOS-based camera allows a PAT system to specify portion of the array. The maximum allowed frame rate increases as the size of the area of interest decreases under certain conditions. A commercially available CMOS camera with 105 fps @ 640×480 is employed in our PAT simulation system, in which only part pixels are used in fact. Beams angle varying in the field of view can be detected after getting across a Cassegrain telescope and an optical focus system. Spot pixel values (8 bits per pixel) reading out from CMOS are transmitted to a DSP subsystem via IEEE 1394 bus, and pointing errors can be computed by the centroid equation. It was shown in test that: (1) 500 fps @ 100×100 is available in acquisition when the field of view is 1mrad; (2)3k fps @ 10×10 is available in tracking when the field of view is 0.1mrad.
AO WFS detector developments at ESO to prepare for the E-ELT
NASA Astrophysics Data System (ADS)
Downing, Mark; Casali, Mark; Finger, Gert; Lewis, Steffan; Marchetti, Enrico; Mehrgan, Leander; Ramsay, Suzanne; Reyes, Javier
2016-07-01
ESO has a very active on-going AO WFS detector development program to not only meet the needs of the current crop of instruments for the VLT, but also has been actively involved in gathering requirements, planning, and developing detectors and controllers/cameras for the instruments in design and being proposed for the E-ELT. This paper provides an overall summary of the AO WFS Detector requirements of the E-ELT instruments currently in design and telescope focal units. This is followed by a description of the many interesting detector, controller, and camera developments underway at ESO to meet these needs; a) the rationale behind and plan to upgrade the 240x240 pixels, 2000fps, "zero noise", L3Vision CCD220 sensor based AONGC camera; b) status of the LGSD/NGSD High QE, 3e- RoN, fast 700fps, 1760x1680 pixels, Visible CMOS Imager and camera development; c) status of and development plans for the Selex SAPHIRA NIR eAPD and controller. Most of the instruments and detector/camera developments are described in more detail in other papers at this conference.
NASA Astrophysics Data System (ADS)
Narayanan, V. L.
2017-12-01
For the first time, high speed imaging of lightning from few isolated tropical thunderstorms are observed from India. The recordings are made from Tirupati (13.6oN, 79.4oE, 180 m above mean sea level) during summer months with a digital camera capable of recording high speed videos up to 480 fps. At 480 fps, each individual video file is recorded for 30 s resulting in 14400 deinterlaced images per video file. An automatic processing algorithm is developed for quick identification and analysis of the lightning events which will be discussed in detail. Preliminary results indicating different types of phenomena associated with lightning like stepped leader, dart leader, luminous channels corresponding to continuing current and M components are discussed. While most of the examples show cloud to ground discharges, few interesting cases of intra-cloud, inter-cloud and cloud-air discharges will also be displayed. This indicates that though high speed cameras with few 1000 fps are preferred for a detailed study on lightning, moderate range CMOS sensor based digital cameras can provide important information as well. The lightning imaging activity presented herein is initiated as an amateur effort and currently plans are underway to propose a suite of supporting instruments to conduct coordinated campaigns. The images discussed here are acquired from normal residential area and indicate how frequent lightning strikes are in such tropical locations during thunderstorms, though no towering structures are nearby. It is expected that popularizing of such recordings made with affordable digital cameras will trigger more interest in lightning research and provide a possible data source from amateur observers paving the way for citizen science.
High-speed adaptive optics line scan confocal retinal imaging for human eye
Wang, Xiaolin; Zhang, Yuhua
2017-01-01
Purpose Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. Methods A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye’s optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. Results The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. Conclusions We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss. PMID:28257458
High-speed adaptive optics line scan confocal retinal imaging for human eye.
Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua
2017-01-01
Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.
High frame rate imaging systems developed in Northwest Institute of Nuclear Technology
NASA Astrophysics Data System (ADS)
Li, Binkang; Wang, Kuilu; Guo, Mingan; Ruan, Linbo; Zhang, Haibing; Yang, Shaohua; Feng, Bing; Sun, Fengrong; Chen, Yanli
2007-01-01
This paper presents high frame rate imaging systems developed in Northwest Institute of Nuclear Technology in recent years. Three types of imaging systems are included. The first type of system utilizes EG&G RETICON Photodiode Array (PDA) RA100A as the image sensor, which can work at up to 1000 frame per second (fps). Besides working continuously, the PDA system is also designed to switch to capture flash light event working mode. A specific time sequence is designed to satisfy this request. The camera image data can be transmitted to remote area by coaxial or optic fiber cable and then be stored. The second type of imaging system utilizes PHOTOBIT Complementary Metal Oxygen Semiconductor (CMOS) PB-MV13 as the image sensor, which has a high resolution of 1280 (H) ×1024 (V) pixels per frame. The CMOS system can operate at up to 500fps in full frame and 4000fps partially. The prototype scheme of the system is presented. The third type of imaging systems adopts charge coupled device (CCD) as the imagers. MINTRON MTV-1881EX, DALSA CA-D1 and CA-D6 camera head are used in the systems development. The features comparison of the RA100A, PB-MV13, and CA-D6 based systems are given in the end.
Road Weather Systems [SD .WMV (720x480/29fps/25.2 MB)
DOT National Transportation Integrated Search
2009-01-01
Iowas road weather information system at work. The Iowa DOT will install new sensors and upgrades to most road weather information system (RWIS) sites. These include: : color cameras, new precipitation sensors, new speed sensors, revised weathervi...
Development and use of an L3CCD high-cadence imaging system for Optical Astronomy
NASA Astrophysics Data System (ADS)
Sheehan, Brendan J.; Butler, Raymond F.
2008-02-01
A high cadence imaging system, based on a Low Light Level CCD (L3CCD) camera, has been developed for photometric and polarimetric applications. The camera system is an iXon DV-887 from Andor Technology, which uses a CCD97 L3CCD detector from E2V technologies. This is a back illuminated device, giving it an extended blue response, and has an active area of 512×512 pixels. The camera system allows frame-rates ranging from 30 fps (full frame) to 425 fps (windowed & binned frame). We outline the system design, concentrating on the calibration and control of the L3CCD camera. The L3CCD detector can be either triggered directly by a GPS timeserver/frequency generator or be internally triggered. A central PC remotely controls the camera computer system and timeserver. The data is saved as standard `FITS' files. The large data loads associated with high frame rates, leads to issues with gathering and storing the data effectively. To overcome such problems, a specific data management approach is used, and a Python/PYRAF data reduction pipeline was written for the Linux environment. This uses calibration data collected either on-site, or from lab based measurements, and enables a fast and reliable method for reducing images. To date, the system has been used twice on the 1.5 m Cassini Telescope in Loiano (Italy) we present the reduction methods and observations made.
Electronic Flash In Data Acquisition
NASA Astrophysics Data System (ADS)
Miller, C. E.
1982-02-01
Photographic acquisition of data often may be simplified, or the data quality improved upon by employing electronic flash sources with traditional equipment or techniques. The relatively short flash duration compared to movie camera shutters, or to the long integration time of video camera provides improved spatial resolution through blur reduction, particularly important as image movement becomes a significant fraction of film format dimension. Greater accuracy typically is achieved in velocity and acceleration determinations by using a stroboscopic light source rather than a movie camera frame-rate control as a time standard. Electrical efficiency often is an important advantage of electronic flash sources since almost any necessary light level for exposure may be produced, yet the source typically is "off" most of the time. Various synchronization techniques greatly expand the precise control of exposure. Biomechanical and sports equipment studies may involve velocities up to 200 feet-per-second, and often will have associated very rapid actions of interest. The need for brief exposures increases H.s one "ZOOMS in on the action." In golf, for example, the swing may be examined using 100 microsecond (Us) flashes at rates of 60 or 120 flashes-per-second (FPS). Accurate determination of linear and rotational velocity of the ball requires 10 Us flashes at 500-1,000 FPS, while sub-Us flashes at 20,000-50,000 FPS are required to resolve the interaction of the ball and the club, head. Some seldom. used techniques involving streak photography are described, with enhanced results obtained by combining strobe with the usual continuous light source. The combination of strobe and a fast electro-mechanical shutter is considered for Us photography under daylight conditions.
A CMOS One-chip Wireless Camera with Digital Image Transmission Function for Capsule Endoscopes
NASA Astrophysics Data System (ADS)
Itoh, Shinya; Kawahito, Shoji; Terakawa, Susumu
This paper presents the design and implementation of a one-chip camera device for capsule endoscopes. This experimental chip integrates functional circuits required for capsule endoscopes and digital image transmission function. The integrated functional blocks include an image array, a timing generator, a clock generator, a voltage regulator, a 10b cyclic A/D converter, and a BPSK modulator. It can be operated autonomously with 3 pins (VDD, GND, and DATAOUT). A prototype image sensor chip which has 320x240 effective pixels was fabricated using 0.25μm CMOS image sensor process and the autonomous imaging was demonstrated. The chip size is 4.84mmx4.34mm. With a 2.0 V power supply, the analog part consumes 950μW and the total power consumption at 2 frames per second (fps) is 2.6mW. Error-free image transmission over a distance of 48cm at 2.5Mbps corresponding to 2fps has been succeeded with inductive coupling.
SU-D-BRC-07: System Design for a 3D Volumetric Scintillation Detector Using SCMOS Cameras
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darne, C; Robertson, D; Alsanea, F
2016-06-15
Purpose: The purpose of this project is to build a volumetric scintillation detector for quantitative imaging of 3D dose distributions of proton beams accurately in near real-time. Methods: The liquid scintillator (LS) detector consists of a transparent acrylic tank (20×20×20 cm{sup 3}) filled with a liquid scintillator that when irradiated with protons generates scintillation light. To track rapid spatial and dose variations in spot scanning proton beams we used three scientific-complementary metal-oxide semiconductor (sCMOS) imagers (2560×2160 pixels). The cameras collect optical signal from three orthogonal projections. To reduce system footprint two mirrors oriented at 45° to the tank surfaces redirectmore » scintillation light to cameras for capturing top and right views. Selection of fixed focal length objective lenses for these cameras was based on their ability to provide large depth of field (DoF) and required field of view (FoV). Multiple cross-hairs imprinted on the tank surfaces allow for image corrections arising from camera perspective and refraction. Results: We determined that by setting sCMOS to 16-bit dynamic range, truncating its FoV (1100×1100 pixels) to image the entire volume of the LS detector, and using 5.6 msec integration time imaging rate can be ramped up to 88 frames per second (fps). 20 mm focal length lens provides a 20 cm imaging DoF and 0.24 mm/pixel resolution. Master-slave camera configuration enable the slaves to initiate image acquisition instantly (within 2 µsec) after receiving a trigger signal. A computer with 128 GB RAM was used for spooling images from the cameras and can sustain a maximum recording time of 2 min per camera at 75 fps. Conclusion: The three sCMOS cameras are capable of high speed imaging. They can therefore be used for quick, high-resolution, and precise mapping of dose distributions from scanned spot proton beams in three dimensions.« less
Noncoherent Symbol Synchronization Techniques
NASA Technical Reports Server (NTRS)
Simon, Marvin
2005-01-01
Traditional methods for establishing symbol synchronization (sync) in digital communication receivers assume that carrier sync has already been established, i.e., the problem is addressed at the baseband level assuming that a 'perfect' estimate of carrier phase is available. We refer to this approach as coherent symbol sync. Since, for NRZ signaling, a suppressed carrier sync loop such as an I-Q Costas loop includes integrate-and-dump (I and D) filters in its in-phase (1) and quadrature (Q) arms, the traditional approach is to first track the carrier in the absence of symbol sync information, then feed back the symbol sync estimate to these filters, and then iterate between the two to a desirable operating level In this paper, we revisit the symbol sync problem by examining methods for obtaining such sync in the absence of carrier phase information, i.e., so-called noncoherent symbol sync loops. We compare the performance of these loops with that of a well-known coherent symbol sync loop and examine the conditions under which one is preferable over the other.
NASA Technical Reports Server (NTRS)
Gradl, Paul
2016-01-01
Paired images were collected using a projected pattern instead of standard painting of the speckle pattern on her abdomen. High Speed cameras were post triggered after movements felt. Data was collected at 120 fps -limited due to 60hz frequency of projector. To ensure that kicks and movement data was real a background test was conducted with no baby movement (to correct for breathing and body motion).
Flight demonstration of a milliarcsecond pointing system for direct exoplanet imaging.
Mendillo, Christopher B; Chakrabarti, Supriya; Cook, Timothy A; Hicks, Brian A; Lane, Benjamin F
2012-10-10
We present flight results from the optical pointing control system onboard the Planetary Imaging Concept Testbed Using a Rocket Experiment (PICTURE) sounding rocket. PICTURE (NASA mission number: 36.225 UG) was launched on 8 October 2011, from White Sands Missile Range. It attempted to directly image the exozodiacal dust disk of ϵ Eridani (K2V, 3.22 pc) down to an inner radius of 1.5 AU using a visible nulling coronagraph. The rocket attitude control system (ACS) provided 627 milliarcsecond (mas) RMS body pointing (~2'' peak-to-valley). The PICTURE fine pointing system (FPS) successfully stabilized the telescope beam to 5.1 mas (0.02λ/D) RMS using an angle tracker camera and fast steering mirror. This level of pointing stability is comparable to that of the Hubble Space Telescope. We present the hardware design of the FPS, a description of the limiting noise sources and a power spectral density analysis of the FPS and rocket ACS in-flight performance.
2003-03-07
File name :DSC_0749.JPG File size :1.1MB(1174690Bytes) Date taken :2003/03/07 13:51:29 Image size :2000 x 1312 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D1H Quality mode :FINE Metering mode :Matrix Exposure mode :Shutter priority Speed light :No Focal length :20 mm Shutter speed :1/500second Aperture :F11.0 Exposure compensation :0 EV White Balance :Auto Lens :20 mm F 2.8 Flash sync mode :N/A Exposure difference :0.0 EV Flexible program :No Sensitivity :ISO200 Sharpening :Normal Image Type :Color Color Mode :Mode II(Adobe RGB) Hue adjustment :3 Saturation Control :N/A Tone compensation :Normal Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A
2002-02-19
File name :DSC_0028.JPG File size :2.8MB(2950833Bytes) Date taken :2002/02/19 09:49:01 Image size :3008 x 2000 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D100 Quality mode :N/A Metering mode :Matrix Exposure mode :Shutter priority Speed light :Yes Focal length :24 mm Shutter speed :1/60second Aperture :F3.5 Exposure compensation :0 EV White Balance :N/A Lens :N/A Flash sync mode :N/A Exposure difference :N/A Flexible program :N/A Sensitivity :N/A Sharpening :N/A Image Type :Color Color Mode :N/A Hue adjustment :N/A Saturation Control :N/A Tone compensation :N/A Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A
2002-02-24
File name :DSC_0047.JPG File size :2.8MB(2931574Bytes) Date taken :2002/02/24 10:06:57 Image size :3008 x 2000 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D100 Quality mode :N/A Metering mode :Matrix Exposure mode :Shutter priority Speed light :Yes Focal length :24 mm Shutter speed :1/180second Aperture :F20.0 Exposure compensation :+0.3 EV White Balance :N/A Lens :N/A Flash sync mode :N/A Exposure difference :N/A Flexible program :N/A Sensitivity :N/A Sharpening :N/A Image Type :Color Color Mode :N/A Hue adjustment :N/A Saturation Control :N/A Tone compensation :N/A Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A
Circular zig-zag scan video format
Peterson, C. Glen; Simmons, Charles M.
1992-01-01
A circular, ziz-zag scan for use with vidicon tubes. A sine wave is generated, rectified and its fourth root extracted. The fourth root, and its inverse, are used to generate horizontal ramp and sync signals. The fourth root is also used to generate a vertical sync signal, and the vertical sync signal, along with the horizontal sync signal, are used to generate the vertical ramp signal. Cathode blanking and preamplifier clamp signals are also obtained from the vertical sync signal.
Feng, Yongqiang; Max, Ludo
2014-01-01
Purpose Studying normal or disordered motor control requires accurate motion tracking of the effectors (e.g., orofacial structures). The cost of electromagnetic, optoelectronic, and ultrasound systems is prohibitive for many laboratories, and limits clinical applications. For external movements (lips, jaw), video-based systems may be a viable alternative, provided that they offer high temporal resolution and sub-millimeter accuracy. Method We examined the accuracy and precision of 2D and 3D data recorded with a system that combines consumer-grade digital cameras capturing 60, 120, or 240 frames per second (fps), retro-reflective markers, commercially-available computer software (APAS, Ariel Dynamics), and a custom calibration device. Results Overall mean error (RMSE) across tests was 0.15 mm for static tracking and 0.26 mm for dynamic tracking, with corresponding precision (SD) values of 0.11 and 0.19 mm, respectively. The effect of frame rate varied across conditions, but, generally, accuracy was reduced at 240 fps. The effect of marker size (3 vs. 6 mm diameter) was negligible at all frame rates for both 2D and 3D data. Conclusion Motion tracking with consumer-grade digital cameras and the APAS software can achieve sub-millimeter accuracy at frame rates that are appropriate for kinematic analyses of lip/jaw movements for both research and clinical purposes. PMID:24686484
A new omni-directional multi-camera system for high resolution surveillance
NASA Astrophysics Data System (ADS)
Cogal, Omer; Akin, Abdulkadir; Seyid, Kerem; Popovic, Vladan; Schmid, Alexandre; Ott, Beat; Wellig, Peter; Leblebici, Yusuf
2014-05-01
Omni-directional high resolution surveillance has a wide application range in defense and security fields. Early systems used for this purpose are based on parabolic mirror or fisheye lens where distortion due to the nature of the optical elements cannot be avoided. Moreover, in such systems, the image resolution is limited to a single image sensor's image resolution. Recently, the Panoptic camera approach that mimics the eyes of flying insects using multiple imagers has been presented. This approach features a novel solution for constructing a spherically arranged wide FOV plenoptic imaging system where the omni-directional image quality is limited by low-end sensors. In this paper, an overview of current Panoptic camera designs is provided. New results for a very-high resolution visible spectrum imaging and recording system inspired from the Panoptic approach are presented. The GigaEye-1 system, with 44 single cameras and 22 FPGAs, is capable of recording omni-directional video in a 360°×100° FOV at 9.5 fps with a resolution over (17,700×4,650) pixels (82.3MP). Real-time video capturing capability is also verified at 30 fps for a resolution over (9,000×2,400) pixels (21.6MP). The next generation system with significantly higher resolution and real-time processing capacity, called GigaEye-2, is currently under development. The important capacity of GigaEye-1 opens the door to various post-processing techniques in surveillance domain such as large perimeter object tracking, very-high resolution depth map estimation and high dynamicrange imaging which are beyond standard stitching and panorama generation methods.
Circular zig-zag scan video format
Peterson, C.G.; Simmons, C.M.
1992-06-09
A circular, ziz-zag scan for use with vidicon tubes is disclosed. A sine wave is generated, rectified and its fourth root extracted. The fourth root, and its inverse, are used to generate horizontal ramp and sync signals. The fourth root is also used to generate a vertical sync signal, and the vertical sync signal, along with the horizontal sync signal, are used to generate the vertical ramp signal. Cathode blanking and preamplifier clamp signals are also obtained from the vertical sync signal. 10 figs.
NASA Astrophysics Data System (ADS)
Sato, M.; Takahashi, Y.; Kudo, T.; Yanagi, Y.; Kobayashi, N.; Yamada, T.; Project, N.; Stenbaek-Nielsen, H. C.; McHarg, M. G.; Haaland, R. K.; Kammae, T.; Cummer, S. A.; Yair, Y.; Lyons, W. A.; Ahrns, J.; Yukman, P.; Warner, T. A.; Sonnenfeld, R. G.; Li, J.; Lu, G.
2011-12-01
The time evolution and spatial distributions of transient luminous events (TLEs) are the key parameters to identify the relationship between TLEs and parent lightning discharges, roles of electromagnetic pulses (EMPs) emitted by horizontal and vertical lightning currents in the formation of TLEs, and the occurrence condition and mechanisms of TLEs. Since the time scales of TLEs is typically less than a few milliseconds, new imaging technique that enable us to capture images with a high time resolution of < 1ms is awaited. By courtesy of "Cosmic Shore" Project conducted by Japan Broadcasting Corporation (NHK), we have carried out optical observations using a high-speed Image-Intensified (II) CMOS camera and a high-vision three-CCD camera from a jet aircraft on November 28 and December 3, 2010 in winter Japan. Using the high-speed II-CMOS camera, it is possible to capture images with 8,300 frames per second (fps), which corresponds to the time resolution of 120 us. Using the high-vision three-CCD camera, it is possible to capture high quality, true color images of TLEs with a 1920x1080 pixel size and with a frame rate of 30 fps. During the two observation flights, we have succeeded to detect 28 sprite events, and 3 elves events totally. In response to this success, we have conducted a combined aircraft and ground-based campaign of TLE observations at the High Plains in summer US. We have installed same NHK high-speed and high-vision cameras in a jet aircraft. In the period from June 27 and July 10, 2011, we have operated aircraft observations in 8 nights, and we have succeeded to capture TLE images for over a hundred events by the high-vision camera and succeeded to acquire over 40 high-speed images simultaneously. At the presentation, we will introduce the outlines of the two aircraft campaigns, and will introduce the characteristics of the time evolution and spatial distributions of TLEs observed in winter Japan, and will show the initial results of high-speed image data analysis of TLEs in summer US.
Preliminary Observations from the 2014 Sand Dunes Experiment
2014-10-01
sync (start) 06/01/2014 09:00 0.00 ms ( latched ) Clock sync (end) 06/18/2014 11:55:00 10.846 ms slow Drift rate 633.471 μs/day (slowing) 22...10m (faired Kevlar) 210.0 m Sample rate 9765.625 Hz Clock sync (start) 06/01/2014 (YD 152) 01:33 0.00s ( latched ) Clock sync (end) 06/19/2014 (YD...02/2014 07:43 0.00s ( latched ) Clock sync (end) 06/16/2014 01:10 38.527 ms fast Drift rate 2.8066 ms/day (fast) 32 Figure 30. SBE39
A CMOS In-Pixel CTIA High Sensitivity Fluorescence Imager.
Murari, Kartikeya; Etienne-Cummings, Ralph; Thakor, Nitish; Cauwenberghs, Gert
2011-10-01
Traditionally, charge coupled device (CCD) based image sensors have held sway over the field of biomedical imaging. Complementary metal oxide semiconductor (CMOS) based imagers so far lack sensitivity leading to poor low-light imaging. Certain applications including our work on animal-mountable systems for imaging in awake and unrestrained rodents require the high sensitivity and image quality of CCDs and the low power consumption, flexibility and compactness of CMOS imagers. We present a 132×124 high sensitivity imager array with a 20.1 μm pixel pitch fabricated in a standard 0.5 μ CMOS process. The chip incorporates n-well/p-sub photodiodes, capacitive transimpedance amplifier (CTIA) based in-pixel amplification, pixel scanners and delta differencing circuits. The 5-transistor all-nMOS pixel interfaces with peripheral pMOS transistors for column-parallel CTIA. At 70 fps, the array has a minimum detectable signal of 4 nW/cm(2) at a wavelength of 450 nm while consuming 718 μA from a 3.3 V supply. Peak signal to noise ratio (SNR) was 44 dB at an incident intensity of 1 μW/cm(2). Implementing 4×4 binning allowed the frame rate to be increased to 675 fps. Alternately, sensitivity could be increased to detect about 0.8 nW/cm(2) while maintaining 70 fps. The chip was used to image single cell fluorescence at 28 fps with an average SNR of 32 dB. For comparison, a cooled CCD camera imaged the same cell at 20 fps with an average SNR of 33.2 dB under the same illumination while consuming over a watt.
A CMOS In-Pixel CTIA High Sensitivity Fluorescence Imager
Murari, Kartikeya; Etienne-Cummings, Ralph; Thakor, Nitish; Cauwenberghs, Gert
2012-01-01
Traditionally, charge coupled device (CCD) based image sensors have held sway over the field of biomedical imaging. Complementary metal oxide semiconductor (CMOS) based imagers so far lack sensitivity leading to poor low-light imaging. Certain applications including our work on animal-mountable systems for imaging in awake and unrestrained rodents require the high sensitivity and image quality of CCDs and the low power consumption, flexibility and compactness of CMOS imagers. We present a 132×124 high sensitivity imager array with a 20.1 μm pixel pitch fabricated in a standard 0.5 μ CMOS process. The chip incorporates n-well/p-sub photodiodes, capacitive transimpedance amplifier (CTIA) based in-pixel amplification, pixel scanners and delta differencing circuits. The 5-transistor all-nMOS pixel interfaces with peripheral pMOS transistors for column-parallel CTIA. At 70 fps, the array has a minimum detectable signal of 4 nW/cm2 at a wavelength of 450 nm while consuming 718 μA from a 3.3 V supply. Peak signal to noise ratio (SNR) was 44 dB at an incident intensity of 1 μW/cm2. Implementing 4×4 binning allowed the frame rate to be increased to 675 fps. Alternately, sensitivity could be increased to detect about 0.8 nW/cm2 while maintaining 70 fps. The chip was used to image single cell fluorescence at 28 fps with an average SNR of 32 dB. For comparison, a cooled CCD camera imaged the same cell at 20 fps with an average SNR of 33.2 dB under the same illumination while consuming over a watt. PMID:23136624
A Low-Cost Method of Ciliary Beat Frequency Measurement Using iPhone and MATLAB: Rabbit Study.
Chen, Jason J; Lemieux, Bryan T; Wong, Brian J F
2016-08-01
(1) To determine ciliary beat frequency (CBF) using a consumer-grade cellphone camera and MATLAB and (2) to evaluate the effectiveness and accuracy of the proposed method. Prospective animal study. Academic otolaryngology department research laboratory. Five ex vivo tracheal samples were extracted from 3 freshly euthanized (<3 hours postmortem) New Zealand white rabbits and incubated for 30 minutes in buffer at 23°C, buffer at 37°C, or 10% formalin at 23°C. Samples were sectioned transversely and observed under a phase-contrast microscope. Cilia movement was recorded through the eyepiece using an iPhone 6 at 240 frames per second (fps). Through MATLAB programming, the video of the 23°C sample was downsampled to 120, 60, and 30 fps, and Fourier analysis was performed on videos of all frame rates and conditions to determine CBF. CBF of the 23°C sample was also calculated manually frame by frame for verification. Recorded at 240 fps, the CBF at 23°C was 5.03 ± 0.4 Hz, and the CBF at 37°C was 9.08 ± 0.49 Hz (P < .001). The sample with 10% formalin did not display any data beyond DC noise. Compared with 240 fps, the means of other frame rates/methods (120, 60, 30 fps; manual counting) at 23°C all showed no statistical difference (P > .05). There is no significant difference between CBF measured via visual inspection and that analyzed by the developed program. Furthermore, all tested acquisition rates are shown to be effective, providing a fast and inexpensive alternative to current CBF measurement protocols. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.
Investigation of kinematics of knuckling shot in soccer
NASA Astrophysics Data System (ADS)
Asai, T.; Hong, S.
2017-02-01
In this study, we use four high-speed video cameras to investigate the swing characteristics of the kicking leg while delivering the knuckling shot in soccer. We attempt to elucidate the impact process of the kicking foot at the instant of its impact with the ball and the technical mechanisms of the knuckling shot via comparison of its curved motion with that of the straight and curved shots. Two high-speed cameras (Fastcam, Photron Inc., Tokyo, Japan; 1000 fps, 1024 × 1024 pixels) are set up 2 m away from the site of impact with a line of sight perpendicular to the kicking-leg side. In addition, two semi-high-speed cameras (EX-F1, Casio Computer Co., Ltd., Tokyo, Japan; 300 fps; 720 × 480 pixels) are positioned, one at the rear and the other on the kicking-leg side, to capture the kicking motion. We observe that the ankle joint at impact in the knuckling shot flexes in an approximate L-shape in a manner similar to the joint flexing for the curve shot. The hip's external rotation torque in the knuckling shot is greater than those of other shots, which suggests the tendency of the kicker to push the heel forward and impact with the inside of the foot. The angle of attack in the knuckling shot is smaller than that in other shots, and we speculate that this small attack angle is a factor in soccer kicks which generate shots with smaller rotational frequencies of the ball.
Effectiveness Testing and Evaluation of Non-Lethal Weapons for Crowd Management
2014-06-01
and Combat Service Support• Program Executive Office Ground Combat Systems • Program Executive Office Soldier TACOM LCMC MG Michael J. Terry Assigned...technologies and explosive ordnance disposal Fire Control: Battlefield digitization; embedded system software; aero ballistics and telemetry ARDEC...influence predictive variables Introduction Crowd Behavior Research at TBRL UNCLASSIFIED 7 Data Measurement • Vicon V8i system • 24 cameras • 120 fps
The DUV Stability of Superlattice-Doped CMOS Detector Arrays
NASA Technical Reports Server (NTRS)
Hoenk, M. E.; Carver, A. G.; Jones, T.; Dickie, M.; Cheng, P.; Greer, H. F.; Nikzad, S.; Sgro, J.; Tsur, S.
2013-01-01
JPL and Alacron have recently developed a high performance, DUV camera with a superlattice doped CMOS imaging detector. Supperlattice doped detectors achieve nearly 100% internal quantum efficiency in the deep and far ultraviolet, and a single layer, Al2O3 antireflection coating enables 64% external quantum efficiency at 263nm. In lifetime tests performed at Applied Materials using 263 nm pulsed, solid state and 193 nm pulsed excimer laser, the quantum efficiency and dark current of the JPL/Alacron camera remained stable to better than 1% precision during long-term exposure to several billion laser pulses, with no measurable degradation, no blooming and no image memory at 1000 fps.
User's manual for SYNC: A FORTRAN program for merging and time-synchronizing data
NASA Technical Reports Server (NTRS)
Maine, R. E.
1981-01-01
The FORTRAN 77 computer program SYNC for merging and time synchronizing data is described. The program SYNC reads one or more input files which contain either synchronous data frames or time-tagged data points, which can be compressed. The program decompresses and time synchronizes the data, correcting for any channel time skews. Interpolation and hold last value synchronization algorithms are available. The output from SYNC is a file of time synchronized data frames at any requested sample rate.
TV synchronization system features stability and noise immunity
NASA Technical Reports Server (NTRS)
Landauer, F. P.
1967-01-01
Horizontal jitter in the video presentation in television systems is prevented by using an additional sync level. This circuitry uses simultaneous signals at both sync and porch frequencies, providing a sync identification from which a coincidence circuit can generate pulses having the required stability and noise immunity.
Long frame sync words for binary PSK telemetry
NASA Technical Reports Server (NTRS)
Levitt, B. K.
1975-01-01
Correlation criteria have previously been established for identifying whether a given binary sequence would be a good frame sync word for phase-shift keyed telemetry. In the past, the search for a good K-bit sync word has involved the application of these criteria to the entire set of 2 exponent K binary K-tuples. It is shown that restricting this search to a much smaller subset consisting of K-bit prefixes of pseudonoise sequences results in sync words of comparable quality, with greatly reduced computer search times for larger values of K. As an example, this procedure is used to find good sync words of length 16-63; from a storage viewpoint, each of these sequences can be generated by a 5- or 6-bit linear feedback shift register.
Controlled impact demonstration on-board (interior) photographic system
NASA Technical Reports Server (NTRS)
May, C. J.
1986-01-01
Langley Research Center (LaRC) was responsible for the design, manufacture, and integration of all hardware required for the photographic system used to film the interior of the controlled impact demonstration (CID) B-720 aircraft during actual crash conditions. Four independent power supplies were constructed to operate the ten high-speed 16 mm cameras and twenty-four floodlights. An up-link command system, furnished by Ames Dryden Flight Research Facility (ADFRF), was necessary to activate the power supplies and start the cameras. These events were accomplished by initiation of relays located on each of the photo power pallets. The photographic system performed beyond expectations. All four power distribution pallets with their 20 year old Minuteman batteries performed flawlessly. All 24 lamps worked. All ten on-board high speed (400 fps) 16 mm cameras containing good resolution film data were recovered.
A novel simultaneous streak and framing camera without principle errors
NASA Astrophysics Data System (ADS)
Jingzhen, L.; Fengshan, S.; Ningwen, L.; Xiangdong, G.; Bin, H.; Qingyang, W.; Hongyi, C.; Yi, C.; Xiaowei, L.
2018-02-01
A novel simultaneous streak and framing camera with continuous access, the perfect information of which is far more important for the exact interpretation and precise evaluation of many detonation events and shockwave phenomena, has been developed. The camera with the maximum imaging frequency of 2 × 106 fps and the maximum scanning velocity of 16.3 mm/μs has fine imaging properties which are the eigen resolution of over 40 lp/mm in the temporal direction and over 60 lp/mm in the spatial direction and the framing frequency principle error of zero for framing record, and the maximum time resolving power of 8 ns and the scanning velocity nonuniformity of 0.136%~-0.277% for streak record. The test data have verified the performance of the camera quantitatively. This camera, simultaneously gained frames and streak with parallax-free and identical time base, is characterized by the plane optical system at oblique incidence different from space system, the innovative camera obscura without principle errors, and the high velocity motor driven beryllium-like rotating mirror, made of high strength aluminum alloy with cellular lateral structure. Experiments demonstrate that the camera is very useful and reliable to take high quality pictures of the detonation events.
Innovative Video Diagnostic Equipment for Material Science
NASA Technical Reports Server (NTRS)
Capuano, G.; Titomanlio, D.; Soellner, W.; Seidel, A.
2012-01-01
Materials science experiments under microgravity increasingly rely on advanced optical systems to determine the physical properties of the samples under investigation. This includes video systems with high spatial and temporal resolution. The acquisition, handling, storage and transmission to ground of the resulting video data are very challenging. Since the available downlink data rate is limited, the capability to compress the video data significantly without compromising the data quality is essential. We report on the development of a Digital Video System (DVS) for EML (Electro Magnetic Levitator) which provides real-time video acquisition, high compression using advanced Wavelet algorithms, storage and transmission of a continuous flow of video with different characteristics in terms of image dimensions and frame rates. The DVS is able to operate with the latest generation of high-performance cameras acquiring high resolution video images up to 4Mpixels@60 fps or high frame rate video images up to about 1000 fps@512x512pixels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Xin, E-mail: xinshih86029@gmail.com; Zhao, Xiangmo, E-mail: xinshih86029@gmail.com; Hui, Fei, E-mail: xinshih86029@gmail.com
Clock synchronization in wireless sensor networks (WSNs) has been studied extensively in recent years and many protocols are put forward based on the point of statistical signal processing, which is an effective way to optimize accuracy. However, the accuracy derived from the statistical data can be improved mainly by sufficient packets exchange, which will consume the limited power resources greatly. In this paper, a reliable clock estimation using linear weighted fusion based on pairwise broadcast synchronization is proposed to optimize sync accuracy without expending additional sync packets. As a contribution, a linear weighted fusion scheme for multiple clock deviations ismore » constructed with the collaborative sensing of clock timestamp. And the fusion weight is defined by the covariance of sync errors for different clock deviations. Extensive simulation results show that the proposed approach can achieve better performance in terms of sync overhead and sync accuracy.« less
Darwin's bee-trap: The kinetics of Catasetum, a new world orchid.
Nicholson, Charles C; Bales, James W; Palmer-Fortune, Joyce E; Nicholson, Robert G
2008-01-01
The orchid genera Catasetum employs a hair-trigger activated, pollen release mechanism, which forcibly attaches pollen sacs onto foraging insects in the New World tropics. This remarkable adaptation was studied extensively by Charles Darwin and he termed this rapid response "sensitiveness." Using high speed video cameras with a frame speed of 1000 fps, this rapid release was filmed and from the subsequent footage, velocity, speed, acceleration, force and kinetic energy were computed.
Verification of the SENTINEL-4 Focal Plane Subsystem
NASA Astrophysics Data System (ADS)
Williges, C.; Hohn, R.; Rossmann, H.; Hilbert, S.; Uhlig, M.; Buchwinkler, K.; Reulke, R.
2017-05-01
The Sentinel-4 payload is a multi-spectral camera system which is designed to monitor atmospheric conditions over Europe. The German Aerospace Center (DLR) in Berlin, Germany conducted the verification campaign of the Focal Plane Subsystem (FPS) on behalf of Airbus Defense and Space GmbH, Ottobrunn, Germany. The FPS consists, inter alia, of two Focal Plane Assemblies (FPAs), one for the UV-VIS spectral range (305 nm … 500 nm), the second for NIR (750 nm … 775 nm). In this publication, we will present in detail the opto-mechanical laboratory set-up of the verification campaign of the Sentinel-4 Qualification Model (QM) which will also be used for the upcoming Flight Model (FM) verification. The test campaign consists mainly of radiometric tests performed with an integrating sphere as homogenous light source. The FPAs have mainly to be operated at 215 K ± 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Furthermore selected test analyses and results will be presented, showing that the Sentinel-4 FPS meets specifications.
NASA Astrophysics Data System (ADS)
Kobayashi, Akizo; Okiharu, Fumiko
2010-07-01
We are developing various modularized materials in physics education to overcome students' misconceptions by use of ICT, i.e. video analysis software and ultra-high-speed digital movies, motion detector, force sensors, current and voltage probes, temperature sensors etc. Furthermore, we also present some new modules of active learning approaches on electric circuit using high speed camera and voltage probes with milliseconds resolution. We are now especially trying to improve conceptual understanding by use of ICT devices with milliseconds resolution in various areas of physics education We give some modules of mass measurements by video analysis of collision phenomena by using high speed cameras—Casio EX-F1(1200 fps), EX-FH20(1000 fps) and EX-FC100/150(1000 fps). We present several new modules on collision phenomena to establish deeper understanding of conservation laws of momentum. We discuss some effective results of trial on a physics education training courses for science educators, and those for science teachers during the renewal years of teacher's license after every ten years in Japan. Finally, we discuss on some typical results of pre-test and post-test in our active learning approaches based on ICT, i.e. some evidence on improvements of physics education (increasing ratio of correct answer are 50%-level).
Analysis of space telescope data collection system
NASA Technical Reports Server (NTRS)
Ingles, F.; Schoggen, W. O.
1980-01-01
The effects of frame synchronization loss were analyzed. A frame sync loss will create loss of data for the frame in which it occurs (since one would not know whether the preceding data was properly in sync or not) and during search from frame sync the system would be losing data. The search mode for reacquisition utilizes multiple search procedures.
Q-Sync Motors in Commercial Refrigeration. Preliminary Test Results and Projected Benefits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A.; Becker, Bryan R.
This report provides background information on various fractional-horsepower electric motor technologies, summarizes initial data from a DOE-sponsored Q-Sync motor demonstration project, and extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of 9–12 W evaporator fan motors to Q-Sync motors.
Fault-Tolerant Self-Stabilizing Distributed Clock Synchronization Protocol for Arbitrary Digraphs
NASA Technical Reports Server (NTRS)
Malekpour, Mahyar R. (Inventor)
2014-01-01
A self-stabilizing network in the form of an arbitrary, non-partitioned digraph includes K nodes having a synchronizer executing a protocol. K-1 monitors of each node may receive a Sync message transmitted from a directly connected node. When the Sync message is received, the logical clock value for the receiving node is set to between 0 and a communication latency value (gamma) if the clock value is less than a minimum event-response delay (D). A new Sync message is also transmitted to any directly connected nodes if the clock value is greater than or equal to both D and a graph threshold (T(sub S)). When the Sync message is not received the synchronizer increments the clock value if the clock value is less than a resynchronization period (P), and resets the clock value and transmits a new Sync message to all directly connected nodes when the clock value equals or exceeds P.
Visible camera imaging of plasmas in Proto-MPEX
NASA Astrophysics Data System (ADS)
Mosby, R.; Skeen, C.; Biewer, T. M.; Renfro, R.; Ray, H.; Shaw, G. C.
2015-11-01
The prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being developed at Oak Ridge National Laboratory (ORNL). This machine plans to study plasma-material interaction (PMI) physics relevant to future fusion reactors. Measurements of plasma light emission will be made on Proto-MPEX using fast, visible framing cameras. The cameras utilize a global shutter, which allows a full frame image of the plasma to be captured and compared at multiple times during the plasma discharge. Typical exposure times are ~10-100 microseconds. The cameras are capable of capturing images at up to 18,000 frames per second (fps). However, the frame rate is strongly dependent on the size of the ``region of interest'' that is sampled. The maximum ROI corresponds to the full detector area, of ~1000x1000 pixels. The cameras have an internal gain, which controls the sensitivity of the 10-bit detector. The detector includes a Bayer filter, for ``true-color'' imaging of the plasma emission. This presentation will exmine the optimized camera settings for use on Proto-MPEX. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725.
A state observer for using a slow camera as a sensor for fast control applications
NASA Astrophysics Data System (ADS)
Gahleitner, Reinhard; Schagerl, Martin
2013-03-01
This contribution concerns about a problem that often arises in vision based control, when a camera is used as a sensor for fast control applications, or more precisely, when the sample rate of the control loop is higher than the frame rate of the camera. In control applications for mechanical axes, e.g. in robotics or automated production, a camera and some image processing can be used as a sensor to detect positions or angles. The sample time in these applications is typically in the range of a few milliseconds or less and this demands the use of a camera with a high frame rate up to 1000 fps. The presented solution is a special state observer that can work with a slower and therefore cheaper camera to estimate the state variables at the higher sample rate of the control loop. To simplify the image processing for the determination of positions or angles and make it more robust, some LED markers are applied to the plant. Simulation and experimental results show that the concept can be used even if the plant is unstable like the inverted pendulum.
Poor Man's Virtual Camera: Real-Time Simultaneous Matting and Camera Pose Estimation.
Szentandrasi, Istvan; Dubska, Marketa; Zacharias, Michal; Herout, Adam
2016-03-18
Today's film and advertisement production heavily uses computer graphics combined with living actors by chromakeying. The matchmoving process typically takes a considerable manual effort. Semi-automatic matchmoving tools exist as well, but they still work offline and require manual check-up and correction. In this article, we propose an instant matchmoving solution for green screen. It uses a recent technique of planar uniform marker fields. Our technique can be used in indie and professional filmmaking as a cheap and ultramobile virtual camera, and for shot prototyping and storyboard creation. The matchmoving technique based on marker fields of shades of green is very computationally efficient: we developed and present in the article a mobile application running at 33 FPS. Our technique is thus available to anyone with a smartphone at low cost and with easy setup, opening space for new levels of filmmakers' creative expression.
Design of CMOS imaging system based on FPGA
NASA Astrophysics Data System (ADS)
Hu, Bo; Chen, Xiaolai
2017-10-01
In order to meet the needs of engineering applications for high dynamic range CMOS camera under the rolling shutter mode, a complete imaging system is designed based on the CMOS imaging sensor NSC1105. The paper decides CMOS+ADC+FPGA+Camera Link as processing architecture and introduces the design and implementation of the hardware system. As for camera software system, which consists of CMOS timing drive module, image acquisition module and transmission control module, the paper designs in Verilog language and drives it to work properly based on Xilinx FPGA. The ISE 14.6 emulator ISim is used in the simulation of signals. The imaging experimental results show that the system exhibits a 1280*1024 pixel resolution, has a frame frequency of 25 fps and a dynamic range more than 120dB. The imaging quality of the system satisfies the requirement of the index.
Defibrillator synchronization tester.
Demirbilek, Fatma N; Krajnak, Mike; Stolarczyk, George
2009-01-01
A defibrillator sync output signal connector provides an ECG synchronization signal that can be used by some defibrillators for the purpose of performing synchronized cardioversion [1]. This process is used to stop an abnormally fast heart rate or cardiac arrhythmia by the delivery of a therapeutic dose of electric current to the heart during the R-wave of the cardiac cycle. Timing the shock to the R-wave prevents the delivery of the shock during the vulnerable period of the cardiac cycle, which could induce ventricular fibrillation [2]. GE patient monitors include a selectable analog output feature, which provides an analog ECG or arterial blood pressure signal. The blood pressure signal can be used to synchronize balloon pumps to provide cardiac assist to post-MI patients with poor injection fraction. Proper operation requires the defibrillator sync and analog output function to be checked. Checkouts are typically done during planned maintenance and after major part replacements such as patient monitor's main CPU board. Checking out defibrillator sync signals could be done using a GE defibrillator sync tester. The defibrillator sync tester provides a loop back path for the defibrillator sync signals to be displayed on the patient monitor screen and eliminates the need for an external oscilloscope.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-16
... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of E[dash]Sync Networks, Inc. (n/k/a ESNI, Inc.), EchoCath, Inc., Edison Brothers Stores, Inc., Electronic Technology Group, Inc. (n... information concerning the securities of E-Sync Networks, Inc. (n/k/a ESNI, Inc.) because it has not filed any...
Strategic options towards an affordable high-performance infrared camera
NASA Astrophysics Data System (ADS)
Oduor, Patrick; Mizuno, Genki; Dutta, Achyut K.; Lewis, Jay; Dhar, Nibir K.
2016-05-01
The promise of infrared (IR) imaging attaining low-cost akin to CMOS sensors success has been hampered by the inability to achieve cost advantages that are necessary for crossover from military and industrial applications into the consumer and mass-scale commercial realm despite well documented advantages. Banpil Photonics is developing affordable IR cameras by adopting new strategies to speed-up the decline of the IR camera cost curve. We present a new short-wave IR (SWIR) camera; 640x512 pixel InGaAs uncooled system that is high sensitivity low noise (<50e-), high dynamic range (100 dB), high-frame rates (> 500 frames per second (FPS)) at full resolution, and low power consumption (< 1 W) in a compact system. This camera paves the way towards mass market adoption by not only demonstrating high-performance IR imaging capability value add demanded by military and industrial application, but also illuminates a path towards justifiable price points essential for consumer facing application industries such as automotive, medical, and security imaging adoption. Among the strategic options presented include new sensor manufacturing technologies that scale favorably towards automation, multi-focal plane array compatible readout electronics, and dense or ultra-small pixel pitch devices.
Ramoun, A A; Emara, A M; Heleil, B A; Darweish, S A; Abou-Ghait, H A
2017-12-01
Fifty one cyclic Egyptian buffaloes were used to study the hormonal profile and follicular dynamics concurrent with CIDR and insulin modified Ovsync TAI programs and their impacts on the consequent fertility responses. The buffaloes were randomly assigned into 3 ovulation synchronization protocols: Ovsync-alone (n = 13, control) CIDR-sync (n = 20) and Insulin-sync (n = 18). Ovsync-alone protocol consisted of two im injections of 20 μg bueserlin (GnRHa) on Day 0 (GnRH 1) and on Day 9 (GnRH 2) with an im injection of 500 μg of cloprostenol sodium (PGF 2 α) on Day 7. The CIDR-sync protocol consisted of the same treatment protocol as in Ovsync in addition to intra-vaginal insertion of CIDR (contains 1.38 gm of progesterone) on Day 0 followed by removal on Day 7. The Insulin-sync protocol consisted of the same treatment protocol as in Ovsync plus 3 sc injections of insulin at a dose of 0.25 i.u/1 kg, on Days 7, 8, and 9. Buffaloes in all groups were inseminated 16 h after GnRH2 by the same inseminator using frozen semen in straws. Blood samples were collected on Days 0, 3, 5 for serum progesterone assay and on Day 9 to measure serum concentrations of estradiol, insulin and IGF-1. Transrectal ultrasonographic scanning of the ovaries was conducted on Days 7, 8 and 9 to record the diameter of the largest follicle. Pregnancy diagnosis was conducted on Day 30 post-TAI by trans-rectal ultrasonographic scanning of the uterus to calculate conception rate. The serum progesterone concentration showed an increase (p < 0.01) in pregnant compared with non-pregnant buffaloes in both Ovsync-alone and Insulin-sync groups, but not in CIDR-sync group (p > 0.05) on Days 3 and 5. The serum estradiol concentration on Day 9 showed an increase (p < 0.01) in pregnant compared with the non-pregnant buffaloes in all of the treated groups. In Insulin-sync and Ovsync-alone groups, the diameter of the largest follicle (LF) was larger (p < 0.01) in pregnant compared with non-pregnant buffaloes, but in CIDR-sync, the diameter of the (LF) was larger (p < 0.01) in non-pregnant compared with pregnant buffaloes. Also, the results showed that the greatest diameter of LF was observed in pregnant buffaloes in Insulin-sync compared with either pregnant or non-pregnant buffaloes in all groups. It is concluded that modified CIDR-sync and Insulin-sync could improve fertility response through modulating hormonal profile and follicular dynamics in buffaloes during low breeding season. Copyright © 2017 Elsevier Inc. All rights reserved.
ShareSync: A Solution for Deterministic Data Sharing over Ethernet
NASA Technical Reports Server (NTRS)
Dunn, Daniel J., II; Koons, William A.; Kennedy, Richard D.; Davis, Philip A.
2007-01-01
As part of upgrading the Contact Dynamics Simulation Laboratory (CDSL) at the NASA Marshall Space Flight Center (MSFC), a simple, cost effective method was needed to communicate data among the networked simulation machines and I/O controllers used to run the facility. To fill this need and similar applicable situations, a generic protocol was developed, called ShareSync. ShareSync is a lightweight, real-time, publish-subscribe Ethernet protocol for simple and deterministic data sharing across diverse machines and operating systems. ShareSync provides a simple Application Programming Interface (API) for simulation programmers to incorporate into their code. The protocol is compatible with virtually all Ethernet-capable machines, is flexible enough to support a variety of applications, is fast enough to provide soft real-time determinism, and is a low-cost resource for distributed simulation development, deployment, and maintenance. The first design cycle iteration of ShareSync has been completed, and the protocol has undergone several testing procedures including endurance and benchmarking tests and approaches the 2001ts data synchronization design goal for the CDSL.
Selective data segment monitoring system. [using shift registers
NASA Technical Reports Server (NTRS)
Wirth, M. N. (Inventor)
1976-01-01
High speed data monitoring apparatus is described for displaying the bit pattern of a selected portion of a block of transmitted data comprising a shift register for receiving the transmitted data and for temporarily containing the consecutive data bits. A programmable sync detector for monitoring the contents of the shift register and for generating a sync signal when the shift register contains a predetermined sync code is included. A counter is described for counting the data bits input to the shift register after the sync signal is generated and for generating a count complete signal when a selected number of data bits have been input to the register. A data storage device is used for storing the contents of the shift register at the time the count complete signal is generated.
Mantokoudis, Georgios; Dähler, Claudia; Dubach, Patrick; Kompis, Martin; Caversaccio, Marco D; Senn, Pascal
2013-01-01
To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280 × 720, 640 × 480, 320 × 240, 160 × 120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0-500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. Higher frame rate (>7 fps), higher camera resolution (>640 × 480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). Webcameras have the potential to improve telecommunication of hearing-impaired individuals.
Motion-Blur-Free High-Speed Video Shooting Using a Resonant Mirror
Inoue, Michiaki; Gu, Qingyi; Takaki, Takeshi; Ishii, Idaku; Tajima, Kenji
2017-01-01
This study proposes a novel concept of actuator-driven frame-by-frame intermittent tracking for motion-blur-free video shooting of fast-moving objects. The camera frame and shutter timings are controlled for motion blur reduction in synchronization with a free-vibration-type actuator vibrating with a large amplitude at hundreds of hertz so that motion blur can be significantly reduced in free-viewpoint high-frame-rate video shooting for fast-moving objects by deriving the maximum performance of the actuator. We develop a prototype of a motion-blur-free video shooting system by implementing our frame-by-frame intermittent tracking algorithm on a high-speed video camera system with a resonant mirror vibrating at 750 Hz. It can capture 1024 × 1024 images of fast-moving objects at 750 fps with an exposure time of 0.33 ms without motion blur. Several experimental results for fast-moving objects verify that our proposed method can reduce image degradation from motion blur without decreasing the camera exposure time. PMID:29109385
Near-infrared high-resolution real-time omnidirectional imaging platform for drone detection
NASA Astrophysics Data System (ADS)
Popovic, Vladan; Ott, Beat; Wellig, Peter; Leblebici, Yusuf
2016-10-01
Recent technological advancements in hardware systems have made higher quality cameras. State of the art panoramic systems use them to produce videos with a resolution of 9000 x 2400 pixels at a rate of 30 frames per second (fps).1 Many modern applications use object tracking to determine the speed and the path taken by each object moving through a scene. The detection requires detailed pixel analysis between two frames. In fields like surveillance systems or crowd analysis, this must be achieved in real time.2 In this paper, we focus on the system-level design of multi-camera sensor acquiring near-infrared (NIR) spectrum and its ability to detect mini-UAVs in a representative rural Swiss environment. The presented results show the UAV detection from the trial that we conducted during a field trial in August 2015.
Memory-based frame synchronizer. [for digital communication systems
NASA Technical Reports Server (NTRS)
Stattel, R. J.; Niswander, J. K. (Inventor)
1981-01-01
A frame synchronizer for use in digital communications systems wherein data formats can be easily and dynamically changed is described. The use of memory array elements provide increased flexibility in format selection and sync word selection in addition to real time reconfiguration ability. The frame synchronizer comprises a serial-to-parallel converter which converts a serial input data stream to a constantly changing parallel data output. This parallel data output is supplied to programmable sync word recognizers each consisting of a multiplexer and a random access memory (RAM). The multiplexer is connected to both the parallel data output and an address bus which may be connected to a microprocessor or computer for purposes of programming the sync word recognizer. The RAM is used as an associative memory or decorder and is programmed to identify a specific sync word. Additional programmable RAMs are used as counter decoders to define word bit length, frame word length, and paragraph frame length.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Esch, Patrick; Crisanti, Marta; Mutti, Paolo
2015-07-01
A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involvedmore » are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)« less
Image-based path planning for automated virtual colonoscopy navigation
NASA Astrophysics Data System (ADS)
Hong, Wei
2008-03-01
Virtual colonoscopy (VC) is a noninvasive method for colonic polyp screening, by reconstructing three-dimensional models of the colon using computerized tomography (CT). In virtual colonoscopy fly-through navigation, it is crucial to generate an optimal camera path for efficient clinical examination. In conventional methods, the centerline of the colon lumen is usually used as the camera path. In order to extract colon centerline, some time consuming pre-processing algorithms must be performed before the fly-through navigation, such as colon segmentation, distance transformation, or topological thinning. In this paper, we present an efficient image-based path planning algorithm for automated virtual colonoscopy fly-through navigation without the requirement of any pre-processing. Our algorithm only needs the physician to provide a seed point as the starting camera position using 2D axial CT images. A wide angle fisheye camera model is used to generate a depth image from the current camera position. Two types of navigational landmarks, safe regions and target regions are extracted from the depth images. Camera position and its corresponding view direction are then determined using these landmarks. The experimental results show that the generated paths are accurate and increase the user comfort during the fly-through navigation. Moreover, because of the efficiency of our path planning algorithm and rendering algorithm, our VC fly-through navigation system can still guarantee 30 FPS.
A single pixel camera video ophthalmoscope
NASA Astrophysics Data System (ADS)
Lochocki, B.; Gambin, A.; Manzanera, S.; Irles, E.; Tajahuerce, E.; Lancis, J.; Artal, P.
2017-02-01
There are several ophthalmic devices to image the retina, from fundus cameras capable to image the whole fundus to scanning ophthalmoscopes with photoreceptor resolution. Unfortunately, these devices are prone to a variety of ocular conditions like defocus and media opacities, which usually degrade the quality of the image. Here, we demonstrate a novel approach to image the retina in real-time using a single pixel camera, which has the potential to circumvent those optical restrictions. The imaging procedure is as follows: a set of spatially coded patterns is projected rapidly onto the retina using a digital micro mirror device. At the same time, the inner product's intensity is measured for each pattern with a photomultiplier module. Subsequently, an image of the retina is reconstructed computationally. Obtained image resolution is up to 128 x 128 px with a varying real-time video framerate up to 11 fps. Experimental results obtained in an artificial eye confirm the tolerance against defocus compared to a conventional multi-pixel array based system. Furthermore, the use of a multiplexed illumination offers a SNR improvement leading to a lower illumination of the eye and hence an increase in patient's comfort. In addition, the proposed system could enable imaging in wavelength ranges where cameras are not available.
Real-time blood flow visualization using the graphics processing unit
NASA Astrophysics Data System (ADS)
Yang, Owen; Cuccia, David; Choi, Bernard
2011-01-01
Laser speckle imaging (LSI) is a technique in which coherent light incident on a surface produces a reflected speckle pattern that is related to the underlying movement of optical scatterers, such as red blood cells, indicating blood flow. Image-processing algorithms can be applied to produce speckle flow index (SFI) maps of relative blood flow. We present a novel algorithm that employs the NVIDIA Compute Unified Device Architecture (CUDA) platform to perform laser speckle image processing on the graphics processing unit. Software written in C was integrated with CUDA and integrated into a LabVIEW Virtual Instrument (VI) that is interfaced with a monochrome CCD camera able to acquire high-resolution raw speckle images at nearly 10 fps. With the CUDA code integrated into the LabVIEW VI, the processing and display of SFI images were performed also at ~10 fps. We present three video examples depicting real-time flow imaging during a reactive hyperemia maneuver, with fluid flow through an in vitro phantom, and a demonstration of real-time LSI during laser surgery of a port wine stain birthmark.
Real-time blood flow visualization using the graphics processing unit
Yang, Owen; Cuccia, David; Choi, Bernard
2011-01-01
Laser speckle imaging (LSI) is a technique in which coherent light incident on a surface produces a reflected speckle pattern that is related to the underlying movement of optical scatterers, such as red blood cells, indicating blood flow. Image-processing algorithms can be applied to produce speckle flow index (SFI) maps of relative blood flow. We present a novel algorithm that employs the NVIDIA Compute Unified Device Architecture (CUDA) platform to perform laser speckle image processing on the graphics processing unit. Software written in C was integrated with CUDA and integrated into a LabVIEW Virtual Instrument (VI) that is interfaced with a monochrome CCD camera able to acquire high-resolution raw speckle images at nearly 10 fps. With the CUDA code integrated into the LabVIEW VI, the processing and display of SFI images were performed also at ∼10 fps. We present three video examples depicting real-time flow imaging during a reactive hyperemia maneuver, with fluid flow through an in vitro phantom, and a demonstration of real-time LSI during laser surgery of a port wine stain birthmark. PMID:21280915
High throughput imaging cytometer with acoustic focussing.
Zmijan, Robert; Jonnalagadda, Umesh S; Carugo, Dario; Kochi, Yu; Lemm, Elizabeth; Packham, Graham; Hill, Martyn; Glynne-Jones, Peter
2015-10-31
We demonstrate an imaging flow cytometer that uses acoustic levitation to assemble cells and other particles into a sheet structure. This technique enables a high resolution, low noise CMOS camera to capture images of thousands of cells with each frame. While ultrasonic focussing has previously been demonstrated for 1D cytometry systems, extending the technology to a planar, much higher throughput format and integrating imaging is non-trivial, and represents a significant jump forward in capability, leading to diagnostic possibilities not achievable with current systems. A galvo mirror is used to track the images of the moving cells permitting exposure times of 10 ms at frame rates of 50 fps with motion blur of only a few pixels. At 80 fps, we demonstrate a throughput of 208 000 beads per second. We investigate the factors affecting motion blur and throughput, and demonstrate the system with fluorescent beads, leukaemia cells and a chondrocyte cell line. Cells require more time to reach the acoustic focus than beads, resulting in lower throughputs; however a longer device would remove this constraint.
Mantokoudis, Georgios; Dähler, Claudia; Dubach, Patrick; Kompis, Martin; Caversaccio, Marco D.; Senn, Pascal
2013-01-01
Objective To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. Methods Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280×720, 640×480, 320×240, 160×120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0–500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. Results Higher frame rate (>7 fps), higher camera resolution (>640×480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). Conclusion Webcameras have the potential to improve telecommunication of hearing-impaired individuals. PMID:23359119
Tan, Quan-Chang; Wu, Jian-Wei; Peng, Fei; Zang, Yuan; Li, Yang; Zhao, Xiong; Lei, Wei; Wu, Zi-Xiang
2016-06-01
OBJECTIVE This study investigated the optimum injection volume of polymethylmethacrylate (PMMA) to augment a novel fenestrated pedicle screw (FPS) with diameter-tapered perforations in the osteoporotic vertebral body, and how the distribution characteristics of PMMA affect the biomechanical performance of this screw. METHODS Two types of FPSs were designed (FPS-A, composed of 6 perforations with an equal diameter of 1.2 mm; and FPS-B, composed of 6 perforations each with a tapered diameter of 1.5 mm, 1.2 mm, and 0.9 mm from tip to head. Each of 28 human cadaveric osteoporotic vertebrae were randomly assigned to 1 of 7 groups: FPS-A1.0: FPS-A+1.0 ml PMMA; FPS-A1.5: FPS-A+1.5 ml PMMA; FPS-A2.0: FPS-A+2.0 ml PMMA; FPS-B1.0: FPS-B+1.0 ml PMMA; FPS-B1.5: FPS-B+1.5 ml PMMA; FPS-B2.0: FPS-B+2.0 ml PMMA; and conventional pedicle screws (CPSs) without PMMA. After the augmentation, 3D CT was performed to assess the cement distribution characteristics and the cement leakage rate. Axial pullout tests were performed to compare the maximum pullout force thereafter. RESULTS The CT construction images showed that PMMA bone cement formed a conical mass around FPS-A and a cylindrical mass around FPS-B. When the injection volume was increased from 1.0 ml to 2.0 ml, the distribution region of the PMMA cement was enlarged, the PMMA was distributed more posteriorly, and the risk of leakage was increased. When the injection volume reached 2.0 ml, the risk of cement leakage was lower for screws having diameter-tapered perforations. The pullout strengths of the augmented FPS-A groups and FPS-B groups were higher than that of the CPS group (p < 0.0001). All FPS-B groups had a higher pullout strength than the FPS-A groups. CONCLUSIONS The diameter of the perforations affects the distribution of PMMA cement. The diameter-tapered design enabled PMMA to form larger bone-PMMA interfaces and achieve a relatively higher pullout strength, although statistical significance was not reached. Study results indicated 1.5-ml of PMMA was a conservative volume for PMMA augmentation; more cement injection would significantly increase the risk of cement leakage.
Video Capture of Plastic Surgery Procedures Using the GoPro HERO 3+.
Graves, Steven Nicholas; Shenaq, Deana Saleh; Langerman, Alexander J; Song, David H
2015-02-01
Significant improvements can be made in recoding surgical procedures, particularly in capturing high-quality video recordings from the surgeons' point of view. This study examined the utility of the GoPro HERO 3+ Black Edition camera for high-definition, point-of-view recordings of plastic and reconstructive surgery. The GoPro HERO 3+ Black Edition camera was head-mounted on the surgeon and oriented to the surgeon's perspective using the GoPro App. The camera was used to record 4 cases: 2 fat graft procedures and 2 breast reconstructions. During cases 1-3, an assistant remotely controlled the GoPro via the GoPro App. For case 4 the GoPro was linked to a WiFi remote, and controlled by the surgeon. Camera settings for case 1 were as follows: 1080p video resolution; 48 fps; Protune mode on; wide field of view; 16:9 aspect ratio. The lighting contrast due to the overhead lights resulted in limited washout of the video image. Camera settings were adjusted for cases 2-4 to a narrow field of view, which enabled the camera's automatic white balance to better compensate for bright lights focused on the surgical field. Cases 2-4 captured video sufficient for teaching or presentation purposes. The GoPro HERO 3+ Black Edition camera enables high-quality, cost-effective video recording of plastic and reconstructive surgery procedures. When set to a narrow field of view and automatic white balance, the camera is able to sufficiently compensate for the contrasting light environment of the operating room and capture high-resolution, detailed video.
Putative mechanisms mediating tolerance for audiovisual stimulus onset asynchrony.
Bhat, Jyoti; Miller, Lee M; Pitt, Mark A; Shahin, Antoine J
2015-03-01
Audiovisual (AV) speech perception is robust to temporal asynchronies between visual and auditory stimuli. We investigated the neural mechanisms that facilitate tolerance for audiovisual stimulus onset asynchrony (AVOA) with EEG. Individuals were presented with AV words that were asynchronous in onsets of voice and mouth movement and judged whether they were synchronous or not. Behaviorally, individuals tolerated (perceived as synchronous) longer AVOAs when mouth movement preceded the speech (V-A) stimuli than when the speech preceded mouth movement (A-V). Neurophysiologically, the P1-N1-P2 auditory evoked potentials (AEPs), time-locked to sound onsets and known to arise in and surrounding the primary auditory cortex (PAC), were smaller for the in-sync than the out-of-sync percepts. Spectral power of oscillatory activity in the beta band (14-30 Hz) following the AEPs was larger during the in-sync than out-of-sync perception for both A-V and V-A conditions. However, alpha power (8-14 Hz), also following AEPs, was larger for the in-sync than out-of-sync percepts only in the V-A condition. These results demonstrate that AVOA tolerance is enhanced by inhibiting low-level auditory activity (e.g., AEPs representing generators in and surrounding PAC) that code for acoustic onsets. By reducing sensitivity to acoustic onsets, visual-to-auditory onset mapping is weakened, allowing for greater AVOA tolerance. In contrast, beta and alpha results suggest the involvement of higher-level neural processes that may code for language cues (phonetic, lexical), selective attention, and binding of AV percepts, allowing for wider neural windows of temporal integration, i.e., greater AVOA tolerance. Copyright © 2015 the American Physiological Society.
High-Speed Video Analysis in a Conceptual Physics Class
NASA Astrophysics Data System (ADS)
Desbien, Dwain M.
2011-09-01
The use of probe ware and computers has become quite common in introductory physics classrooms. Video analysis is also becoming more popular and is available to a wide range of students through commercially available and/or free software.2,3 Video analysis allows for the study of motions that cannot be easily measured in the traditional lab setting and also allows real-world situations to be analyzed. Many motions are too fast to easily be captured at the standard video frame rate of 30 frames per second (fps) employed by most video cameras. This paper will discuss using a consumer camera that can record high-frame-rate video in a college-level conceptual physics class. In particular this will involve the use of model rockets to determine the acceleration during the boost period right at launch and compare it to a simple model of the expected acceleration.
A Reconfigurable Real-Time Compressive-Sampling Camera for Biological Applications
Fu, Bo; Pitter, Mark C.; Russell, Noah A.
2011-01-01
Many applications in biology, such as long-term functional imaging of neural and cardiac systems, require continuous high-speed imaging. This is typically not possible, however, using commercially available systems. The frame rate and the recording time of high-speed cameras are limited by the digitization rate and the capacity of on-camera memory. Further restrictions are often imposed by the limited bandwidth of the data link to the host computer. Even if the system bandwidth is not a limiting factor, continuous high-speed acquisition results in very large volumes of data that are difficult to handle, particularly when real-time analysis is required. In response to this issue many cameras allow a predetermined, rectangular region of interest (ROI) to be sampled, however this approach lacks flexibility and is blind to the image region outside of the ROI. We have addressed this problem by building a camera system using a randomly-addressable CMOS sensor. The camera has a low bandwidth, but is able to capture continuous high-speed images of an arbitrarily defined ROI, using most of the available bandwidth, while simultaneously acquiring low-speed, full frame images using the remaining bandwidth. In addition, the camera is able to use the full-frame information to recalculate the positions of targets and update the high-speed ROIs without interrupting acquisition. In this way the camera is capable of imaging moving targets at high-speed while simultaneously imaging the whole frame at a lower speed. We have used this camera system to monitor the heartbeat and blood cell flow of a water flea (Daphnia) at frame rates in excess of 1500 fps. PMID:22028852
Assessing the mental frame syncing in the elderly: a virtual reality protocol.
Serino, Silvia; Cipresso, Pietro; Gaggioli, Andrea; Riva, Giuseppe
2014-01-01
Decline in spatial memory in the elderly is often underestimated, and it is crucial to fully investigate the cognitive underpinnings of early spatial impairment. A virtual reality-based procedure was developed to assess deficit in the "mental frame syncing", namely the cognitive ability that allows an effective orientation by synchronizing the allocentric view-point independent representation with the allocentric view-point dependent representation. A pilot study was carried out to evaluate abilities in the mental frame syncing in a sample of 16 elderly participants. Preliminary results indicated that the general cognitive functioning was associated with the ability in the synchronization between these two allocentric references frames.
LEFPS1, a Tomato Farnesyl Pyrophosphate Gene Highly Expressed during Early Fruit Development1
Gaffe, Joel; Bru, Jean-Philippe; Causse, Mathilde; Vidal, Alain; Stamitti-Bert, Linda; Carde, Jean-Pierre; Gallusci, Philippe
2000-01-01
Farnesyl pyrophosphate synthase (FPS) catalyzes the synthesis of farnesyl pyrophosphate, a key intermediate in sterol and sesquiterpene biosynthesis. Using a polymerase chain reaction-based approach, we have characterized LeFPS1, a tomato (Lycoperscion esculentum cv Wva 106) fruit cDNA, which encodes a functional FPS. We demonstrate that tomato FPSs are encoded by a small multigenic family with genes located on chromosomes 10 and 12. Consistent with farnesyl pyrophosphate requirement in sterol biosynthesis, FPS genes are ubiquitously expressed in tomato plants. Using an LeFPS1 specific probe, we show that the corresponding gene can account for most of FPS mRNA in most plant organs, but not during young seedling development, indicating a differential regulation of FPS genes in tomato. FPS gene expression is also under strict developmental control: FPS mRNA was mainly abundant in young organs and decreased as organs matured with the exception of fruits that presented a biphasic accumulation pattern. In this latter case in situ hybridization studies have shown that FPS mRNA is similarly abundant in all tissues of young fruit. Taken together our results suggest that several FPS isoforms are involved in tomato farnesyl pyrophosphate metabolism and that FPS genes are mostly expressed in relation to cell division and enlargement. PMID:10938353
Colorful Packages: Encapsulation of Fluorescent Proteins in Complex Coacervate Core Micelles
Westphal, Adrie H.; Kleijn, J. Mieke; Borst, Jan Willem
2017-01-01
Encapsulation of proteins can be beneficial for food and biomedical applications. To study their biophysical properties in complex coacervate core micelles (C3Ms), we previously encapsulated enhanced green fluorescent protein (EGFP) and its monomeric variant, mEGFP, with the cationic-neutral diblock copolymer poly(2-methyl-vinyl-pyridinium)n-b-poly(ethylene-oxide)m (P2MVPn-b-PEOm) as enveloping material. C3Ms with high packaging densities of fluorescent proteins (FPs) were obtained, resulting in a restricted orientational freedom of the protein molecules, influencing their structural and spectral properties. To address the generality of this behavior, we encapsulated seven FPs with P2MVP41-b-PEO205 and P2MVP128-b-PEO477. Dynamic light scattering and fluorescence correlation spectroscopy showed lower encapsulation efficiencies for members of the Anthozoa class (anFPs) than for Hydrozoa FPs derived from Aequorea victoria (avFPs). Far-UV CD spectra of the free FPs showed remarkable differences between avFPs and anFPs, caused by rounder barrel structures for avFPs and more elliptic ones for anFPs. These structural differences, along with the differences in charge distribution, might explain the variations in encapsulation efficiency between avFPs and anFPs. Furthermore, the avFPs remain monomeric in C3Ms with minor spectral and structural changes. In contrast, the encapsulation of anFPs gives rise to decreased quantum yields (monomeric Kusabira Orange 2 (mKO2) and Tag red fluorescent protein (TagRFP)) or to a pKa shift of the chromophore (FP variant mCherry). PMID:28753915
Fabrication of DIRC radiator bars and plates at InSync, Inc.
NASA Astrophysics Data System (ADS)
Tonnessen, T. W.
2017-12-01
Fabrication of quality radiator bars and plates is paramount to a successful DIRC project. This write up discusses the trials and tribulations of the manufacture of ~600 bars for the BaBar DIRC project and discusses the history and current capabilities of InSync, Inc.
Andrade, Paola; Caudepón, Daniel; Arró, Montserrat
2016-01-01
Farnesyl diphosphate synthase (FPS) catalyzes the synthesis of farnesyl diphosphate from isopentenyl diphosphate and dimethylallyl diphosphate. Arabidopsis (Arabidopsis thaliana) contains two genes (FPS1 and FPS2) encoding FPS. Single fps1 and fps2 knockout mutants are phenotypically indistinguishable from wild-type plants, while fps1/fps2 double mutants are embryo lethal. To assess the effect of FPS down-regulation at postembryonic developmental stages, we generated Arabidopsis conditional knockdown mutants expressing artificial microRNAs devised to simultaneously silence both FPS genes. Induction of silencing from germination rapidly caused chlorosis and a strong developmental phenotype that led to seedling lethality. However, silencing of FPS after seed germination resulted in a slight developmental delay only, although leaves and cotyledons continued to show chlorosis and altered chloroplasts. Metabolomic analyses also revealed drastic changes in the profile of sterols, ubiquinones, and plastidial isoprenoids. RNA sequencing and reverse transcription-quantitative polymerase chain reaction transcriptomic analysis showed that a reduction in FPS activity levels triggers the misregulation of genes involved in biotic and abiotic stress responses, the most prominent one being the rapid induction of a set of genes related to the jasmonic acid pathway. Down-regulation of FPS also triggered an iron-deficiency transcriptional response that is consistent with the iron-deficient phenotype observed in FPS-silenced plants. The specific inhibition of the sterol biosynthesis pathway by chemical and genetic blockage mimicked these transcriptional responses, indicating that sterol depletion is the primary cause of the observed alterations. Our results highlight the importance of sterol homeostasis for normal chloroplast development and function and reveal important clues about how isoprenoid and sterol metabolism is integrated within plant physiology and development. PMID:27382138
Manzano, David; Andrade, Paola; Caudepón, Daniel; Altabella, Teresa; Arró, Montserrat; Ferrer, Albert
2016-09-01
Farnesyl diphosphate synthase (FPS) catalyzes the synthesis of farnesyl diphosphate from isopentenyl diphosphate and dimethylallyl diphosphate. Arabidopsis (Arabidopsis thaliana) contains two genes (FPS1 and FPS2) encoding FPS. Single fps1 and fps2 knockout mutants are phenotypically indistinguishable from wild-type plants, while fps1/fps2 double mutants are embryo lethal. To assess the effect of FPS down-regulation at postembryonic developmental stages, we generated Arabidopsis conditional knockdown mutants expressing artificial microRNAs devised to simultaneously silence both FPS genes. Induction of silencing from germination rapidly caused chlorosis and a strong developmental phenotype that led to seedling lethality. However, silencing of FPS after seed germination resulted in a slight developmental delay only, although leaves and cotyledons continued to show chlorosis and altered chloroplasts. Metabolomic analyses also revealed drastic changes in the profile of sterols, ubiquinones, and plastidial isoprenoids. RNA sequencing and reverse transcription-quantitative polymerase chain reaction transcriptomic analysis showed that a reduction in FPS activity levels triggers the misregulation of genes involved in biotic and abiotic stress responses, the most prominent one being the rapid induction of a set of genes related to the jasmonic acid pathway. Down-regulation of FPS also triggered an iron-deficiency transcriptional response that is consistent with the iron-deficient phenotype observed in FPS-silenced plants. The specific inhibition of the sterol biosynthesis pathway by chemical and genetic blockage mimicked these transcriptional responses, indicating that sterol depletion is the primary cause of the observed alterations. Our results highlight the importance of sterol homeostasis for normal chloroplast development and function and reveal important clues about how isoprenoid and sterol metabolism is integrated within plant physiology and development. © 2016 American Society of Plant Biologists. All rights reserved.
Smart mobility solution with multiple input Output interface.
Sethi, Aartika; Deb, Sujay; Ranjan, Prabhat; Sardar, Arghya
2017-07-01
Smart wheelchairs are commonly used to provide solution for mobility impairment. However their usage is limited primarily due to high cost owing from sensors required for giving input, lack of adaptability for different categories of input and limited functionality. In this paper we propose a smart mobility solution using smartphone with inbuilt sensors (accelerometer, camera and speaker) as an input interface. An Emotiv EPOC+ is also used for motor imagery based input control synced with facial expressions in cases of extreme disability. Apart from traction, additional functions like home security and automation are provided using Internet of Things (IoT) and web interfaces. Although preliminary, our results suggest that this system can be used as an integrated and efficient solution for people suffering from mobility impairment. The results also indicate a decent accuracy is obtained for the overall system.
A synchronous strobed laser light sheet for helicopter model rotor flow visualization
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.; Rhodes, David B.; Jones, Stephen B.; Franke, John M.
1990-01-01
A synchronous, strobed laser light sheet has been developed for use in flow visualization of a helicopter rotor model. The light sheet strobe circuit included selectable blade position, strobe duration, and multiple pulses per revolution for rotors having 2 to 9 blades. The flow was seeded with propylene glycol. Between runs, a calibration grid board was placed in the plane of the laser sheet and recorded with the video camera at the position used to record the flow field. A slip-sync mode permitted slow motion visualization of the flow field over complete rotations of the rotor. The system was used to make two-dimensional flow field cuts of a four-bladed rotor operating at advance ratio of 0.37 at wind tunnel speeds up to 79.25 meters per second (260 feet per second).
Wright, Bruce; Lockyer, Jocelyn; Fidler, Herta; Hofmeister, Marianna
2007-11-01
To examine the beliefs and attitudes of FPs and health care professionals (HCPs) regarding FPs' roles and responsibilities on interdisciplinary geriatric health care teams. Qualitative study using focus groups. Calgary Health Region. Seventeen FPs and 22 HCPs working on geriatric health care teams. Four 90-minute focus groups were conducted with FPs, followed by 2 additional 90-minute focus groups with HCPs. The FP focus groups discussed 4 vignettes of typical teamwork scenarios. Discussions were transcribed and the 4 researchers analyzed and coded themes and subthemes and developed the HCP focus group questions. These questions asked about HCPs' expectations of FPs on teams, experiences with FPs on teams, and perspectives on optimal roles on teams. Several meetings were held to determine themes and subthemes. Family physicians identified patient centredness, role delineation for team members, team dynamics, and team structure as critical to team success. Both FPs and HCPs had a continuum of beliefs about the role FPs should play on teams, including whether FPs should be autonomous or collaborative decision makers, the extent to which FPs should work within or outside teams, whether FPs should be leaders or simply members of teams, and the level of responsibility implied or explicit in their roles. Comments from FPs and HCPs identified intraprofessional and interprofessional tensions that could affect team practice and impede the development of high-functioning teams. It will be important, as primary care reform continues, to help FPs and HCPs learn how to work together effectively on teams so that patients receive the best possible care.
Spectral characterisation and noise performance of Vanilla—an active pixel sensor
NASA Astrophysics Data System (ADS)
Blue, Andrew; Bates, R.; Bohndiek, S. E.; Clark, A.; Arvanitis, Costas D.; Greenshaw, T.; Laing, A.; Maneuski, D.; Turchetta, R.; O'Shea, V.
2008-06-01
This work will report on the characterisation of a new active pixel sensor, Vanilla. The Vanilla comprises of 512×512 (25μm 2) pixels. The sensor has a 12 bit digital output for full-frame mode, although it can also be readout in analogue mode, whereby it can also be read in a fully programmable region-of-interest (ROI) mode. In full frame, the sensor can operate at a readout rate of more than 100 frames per second (fps), while in ROI mode, the speed depends on the size, shape and number of ROIs. For example, an ROI of 6×6 pixels can be read at 20,000 fps in analogue mode. Using photon transfer curve (PTC) measurements allowed for the calculation of the read noise, shot noise, full-well capacity and camera gain constant of the sensor. Spectral response measurements detailed the quantum efficiency (QE) of the detector through the UV and visible region. Analysis of the ROI readout mode was also performed. Such measurements suggest that the Vanilla APS (active pixel sensor) will be suitable for a wide range of applications including particle physics and medical imaging.
Verification of the Sentinel-4 focal plane subsystem
NASA Astrophysics Data System (ADS)
Williges, Christian; Uhlig, Mathias; Hilbert, Stefan; Rossmann, Hannes; Buchwinkler, Kevin; Babben, Steffen; Sebastian, Ilse; Hohn, Rüdiger; Reulke, Ralf
2017-09-01
The Sentinel-4 payload is a multi-spectral camera system, designed to monitor atmospheric conditions over Europe from a geostationary orbit. The German Aerospace Center, DLR Berlin, conducted the verification campaign of the Focal Plane Subsystem (FPS) during the second half of 2016. The FPS consists, of two Focal Plane Assemblies (FPAs), two Front End Electronics (FEEs), one Front End Support Electronic (FSE) and one Instrument Control Unit (ICU). The FPAs are designed for two spectral ranges: UV-VIS (305 nm - 500 nm) and NIR (750 nm - 775 nm). In this publication, we will present in detail the set-up of the verification campaign of the Sentinel-4 Qualification Model (QM). This set up will also be used for the upcoming Flight Model (FM) verification, planned for early 2018. The FPAs have to be operated at 215 K +/- 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. The test campaign consists mainly of radiometric tests. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Selected test analyses and results will be presented.
Stereo and IMU-Assisted Visual Odometry for Small Robots
NASA Technical Reports Server (NTRS)
2012-01-01
This software performs two functions: (1) taking stereo image pairs as input, it computes stereo disparity maps from them by cross-correlation to achieve 3D (three-dimensional) perception; (2) taking a sequence of stereo image pairs as input, it tracks features in the image sequence to estimate the motion of the cameras between successive image pairs. A real-time stereo vision system with IMU (inertial measurement unit)-assisted visual odometry was implemented on a single 750 MHz/520 MHz OMAP3530 SoC (system on chip) from TI (Texas Instruments). Frame rates of 46 fps (frames per second) were achieved at QVGA (Quarter Video Graphics Array i.e. 320 240), or 8 fps at VGA (Video Graphics Array 640 480) resolutions, while simultaneously tracking up to 200 features, taking full advantage of the OMAP3530's integer DSP (digital signal processor) and floating point ARM processors. This is a substantial advancement over previous work as the stereo implementation produces 146 Mde/s (millions of disparities evaluated per second) in 2.5W, yielding a stereo energy efficiency of 58.8 Mde/J, which is 3.75 better than prior DSP stereo while providing more functionality.
VizieR Online Data Catalog: IN-SYNC. II. Candidate young stars in NGC 1333 (Foster+, 2015)
NASA Astrophysics Data System (ADS)
Foster, J. B.; Cottaar, M.; Covey, K. R.; Arce, H. G.; Meyer, M. R.; Nidever, D. L.; Stassun, K. G.; Tan, J. C.; Chojnowski, S. D.; da Rio, N.; Flaherty, K. M.; Rebull, L.; Frinchaboy, P. M.; Majewski, S. R.; Skrutskie, M.; Wilson, J. C.; Zasowski, G.
2015-06-01
Spectra were obtained using the APOGEE multiobject spectrograph (1.51-1.69um with R~22500). The details of the data reduction and spectral fitting are presented in Paper I (INfrared Spectra of Young Nebulous Clusters (IN-SYNC); Cottaar et al. (2014, J/ApJ/794/125). (3 data files).
Positive selection and functional divergence of farnesyl pyrophosphate synthase genes in plants.
Qian, Jieying; Liu, Yong; Chao, Naixia; Ma, Chengtong; Chen, Qicong; Sun, Jian; Wu, Yaosheng
2017-02-04
Farnesyl pyrophosphate synthase (FPS) belongs to the short-chain prenyltransferase family, and it performs a conserved and essential role in the terpenoid biosynthesis pathway. However, its classification, evolutionary history, and the forces driving the evolution of FPS genes in plants remain poorly understood. Phylogeny and positive selection analysis was used to identify the evolutionary forces that led to the functional divergence of FPS in plants, and recombinant detection was undertaken using the Genetic Algorithm for Recombination Detection (GARD) method. The dataset included 68 FPS variation pattern sequences (2 gymnosperms, 10 monocotyledons, 54 dicotyledons, and 2 outgroups). This study revealed that the FPS gene was under positive selection in plants. No recombinant within the FPS gene was found. Therefore, it was inferred that the positive selection of FPS had not been influenced by a recombinant episode. The positively selected sites were mainly located in the catalytic center and functional areas, which indicated that the 98S and 234D were important positively selected sites for plant FPS in the terpenoid biosynthesis pathway. They were located in the FPS conserved domain of the catalytic site. We inferred that the diversification of FPS genes was associated with functional divergence and could be driven by positive selection. It was clear that protein sequence evolution via positive selection was able to drive adaptive diversification in plant FPS proteins. This study provides information on the classification and positive selection of plant FPS genes, and the results could be useful for further research on the regulation of triterpenoid biosynthesis.
NASA Astrophysics Data System (ADS)
Min, Jae-Hong; Gelo, Nikolas J.; Jo, Hongki
2016-04-01
The newly developed smartphone application, named RINO, in this study allows measuring absolute dynamic displacements and processing them in real time using state-of-the-art smartphone technologies, such as high-performance graphics processing unit (GPU), in addition to already powerful CPU and memories, embedded high-speed/ resolution camera, and open-source computer vision libraries. A carefully designed color-patterned target and user-adjustable crop filter enable accurate and fast image processing, allowing up to 240fps for complete displacement calculation and real-time display. The performances of the developed smartphone application are experimentally validated, showing comparable accuracy with those of conventional laser displacement sensor.
Linear momentum, angular momentum and energy in the linear collision between two balls
NASA Astrophysics Data System (ADS)
Hanisch, C.; Hofmann, F.; Ziese, M.
2018-01-01
In an experiment of the basic physics laboratory, kinematical motion processes were analysed. The motion was recorded with a standard video camera having frame rates from 30 to 240 fps the videos were processed using video analysis software. Video detection was used to analyse the symmetric one-dimensional collision between two balls. Conservation of linear and angular momentum lead to a crossover from rolling to sliding directly after the collision. By variation of the rolling radius the system could be tuned from a regime in which the balls move away from each other after the collision to a situation in which they re-collide.
Video Capture of Plastic Surgery Procedures Using the GoPro HERO 3+
Graves, Steven Nicholas; Shenaq, Deana Saleh; Langerman, Alexander J.
2015-01-01
Background: Significant improvements can be made in recoding surgical procedures, particularly in capturing high-quality video recordings from the surgeons’ point of view. This study examined the utility of the GoPro HERO 3+ Black Edition camera for high-definition, point-of-view recordings of plastic and reconstructive surgery. Methods: The GoPro HERO 3+ Black Edition camera was head-mounted on the surgeon and oriented to the surgeon’s perspective using the GoPro App. The camera was used to record 4 cases: 2 fat graft procedures and 2 breast reconstructions. During cases 1-3, an assistant remotely controlled the GoPro via the GoPro App. For case 4 the GoPro was linked to a WiFi remote, and controlled by the surgeon. Results: Camera settings for case 1 were as follows: 1080p video resolution; 48 fps; Protune mode on; wide field of view; 16:9 aspect ratio. The lighting contrast due to the overhead lights resulted in limited washout of the video image. Camera settings were adjusted for cases 2-4 to a narrow field of view, which enabled the camera’s automatic white balance to better compensate for bright lights focused on the surgical field. Cases 2-4 captured video sufficient for teaching or presentation purposes. Conclusions: The GoPro HERO 3+ Black Edition camera enables high-quality, cost-effective video recording of plastic and reconstructive surgery procedures. When set to a narrow field of view and automatic white balance, the camera is able to sufficiently compensate for the contrasting light environment of the operating room and capture high-resolution, detailed video. PMID:25750851
Prototypic Development and Evaluation of a Medium Format Metric Camera
NASA Astrophysics Data System (ADS)
Hastedt, H.; Rofallski, R.; Luhmann, T.; Rosenbauer, R.; Ochsner, D.; Rieke-Zapp, D.
2018-05-01
Engineering applications require high-precision 3D measurement techniques for object sizes that vary between small volumes (2-3 m in each direction) and large volumes (around 20 x 20 x 1-10 m). The requested precision in object space (1σ RMS) is defined to be within 0.1-0.2 mm for large volumes and less than 0.01 mm for small volumes. In particular, focussing large volume applications the availability of a metric camera would have different advantages for several reasons: 1) high-quality optical components and stabilisations allow for a stable interior geometry of the camera itself, 2) a stable geometry leads to a stable interior orientation that enables for an a priori camera calibration, 3) a higher resulting precision can be expected. With this article the development and accuracy evaluation of a new metric camera, the ALPA 12 FPS add|metric will be presented. Its general accuracy potential is tested against calibrated lengths in a small volume test environment based on the German Guideline VDI/VDE 2634.1 (2002). Maximum length measurement errors of less than 0.025 mm are achieved with different scenarios having been tested. The accuracy potential for large volumes is estimated within a feasibility study on the application of photogrammetric measurements for the deformation estimation on a large wooden shipwreck in the German Maritime Museum. An accuracy of 0.2 mm-0.4 mm is reached for a length of 28 m (given by a distance from a lasertracker network measurement). All analyses have proven high stabilities of the interior orientation of the camera and indicate the applicability for a priori camera calibration for subsequent 3D measurements.
A miniature low-cost LWIR camera with a 160×120 microbolometer FPA
NASA Astrophysics Data System (ADS)
Tepegoz, Murat; Kucukkomurler, Alper; Tankut, Firat; Eminoglu, Selim; Akin, Tayfun
2014-06-01
This paper presents the development of a miniature LWIR thermal camera, MSE070D, which targets value performance infrared imaging applications, where a 160x120 CMOS-based microbolometer FPA is utilized. MSE070D features a universal USB interface that can communicate with computers and some particular mobile devices in the market. In addition, it offers high flexibility and mobility with the help of its USB powered nature, eliminating the need for any external power source, thanks to its low-power requirement option. MSE070D provides thermal imaging with its 1.65 inch3 volume with the use of a vacuum packaged CMOS-based microbolometer type thermal sensor MS1670A-VP, achieving moderate performance with a very low production cost. MSE070D allows 30 fps thermal video imaging with the 160x120 FPA size while resulting in an NETD lower than 350 mK with f/1 optics. It is possible to obtain test electronics and software, miniature camera cores, complete Application Programming Interfaces (APIs) and relevant documentation with MSE070D, as MikroSens want to help its customers to evaluate its products and to ensure quick time-to-market for systems manufacturers.
Proposed patient motion monitoring system using feature point tracking with a web camera.
Miura, Hideharu; Ozawa, Shuichi; Matsuura, Takaaki; Yamada, Kiyoshi; Nagata, Yasushi
2017-12-01
Patient motion monitoring systems play an important role in providing accurate treatment dose delivery. We propose a system that utilizes a web camera (frame rate up to 30 fps, maximum resolution of 640 × 480 pixels) and an in-house image processing software (developed using Microsoft Visual C++ and OpenCV). This system is simple to use and convenient to set up. The pyramidal Lucas-Kanade method was applied to calculate motions for each feature point by analysing two consecutive frames. The image processing software employs a color scheme where the defined feature points are blue under stable (no movement) conditions and turn red along with a warning message and an audio signal (beeping alarm) for large patient movements. The initial position of the marker was used by the program to determine the marker positions in all the frames. The software generates a text file that contains the calculated motion for each frame and saves it as a compressed audio video interleave (AVI) file. We proposed a patient motion monitoring system using a web camera, which is simple and convenient to set up, to increase the safety of treatment delivery.
The threshold of vapor channel formation in water induced by pulsed CO2 laser
NASA Astrophysics Data System (ADS)
Guo, Wenqing; Zhang, Xianzeng; Zhan, Zhenlin; Xie, Shusen
2012-12-01
Water plays an important role in laser ablation. There are two main interpretations of laser-water interaction: hydrokinetic effect and vapor phenomenon. The two explanations are reasonable in some way, but they can't explain the mechanism of laser-water interaction completely. In this study, the dynamic process of vapor channel formation induced by pulsed CO2 laser in static water layer was monitored by high-speed camera. The wavelength of pulsed CO2 laser is 10.64 um, and pulse repetition rate is 60 Hz. The laser power ranged from 1 to 7 W with a step of 0.5 W. The frame rate of high-speed camera used in the experiment was 80025 fps. Based on high-speed camera pictures, the dynamic process of vapor channel formation was examined, and the threshold of vapor channel formation, pulsation period, the volume, the maximum depth and corresponding width of vapor channel were determined. The results showed that the threshold of vapor channel formation was about 2.5 W. Moreover, pulsation period, the maximum depth and corresponding width of vapor channel increased with the increasing of the laser power.
Fast Markerless Tracking for Augmented Reality in Planar Environment
NASA Astrophysics Data System (ADS)
Basori, Ahmad Hoirul; Afif, Fadhil Noer; Almazyad, Abdulaziz S.; AbuJabal, Hamza Ali S.; Rehman, Amjad; Alkawaz, Mohammed Hazim
2015-12-01
Markerless tracking for augmented reality should not only be accurate but also fast enough to provide a seamless synchronization between real and virtual beings. Current reported methods showed that a vision-based tracking is accurate but requires high computational power. This paper proposes a real-time hybrid-based method for tracking unknown environments in markerless augmented reality. The proposed method provides collaboration of vision-based approach with accelerometers and gyroscopes sensors as camera pose predictor. To align the augmentation relative to camera motion, the tracking method is done by substituting feature-based camera estimation with combination of inertial sensors with complementary filter to provide more dynamic response. The proposed method managed to track unknown environment with faster processing time compared to available feature-based approaches. Moreover, the proposed method can sustain its estimation in a situation where feature-based tracking loses its track. The collaboration of sensor tracking managed to perform the task for about 22.97 FPS, up to five times faster than feature-based tracking method used as comparison. Therefore, the proposed method can be used to track unknown environments without depending on amount of features on scene, while requiring lower computational cost.
Full image-processing pipeline in field-programmable gate array for a small endoscopic camera
NASA Astrophysics Data System (ADS)
Mostafa, Sheikh Shanawaz; Sousa, L. Natércia; Ferreira, Nuno Fábio; Sousa, Ricardo M.; Santos, Joao; Wäny, Martin; Morgado-Dias, F.
2017-01-01
Endoscopy is an imaging procedure used for diagnosis as well as for some surgical purposes. The camera used for the endoscopy should be small and able to produce a good quality image or video, to reduce discomfort of the patients, and to increase the efficiency of the medical team. To achieve these fundamental goals, a small endoscopy camera with a footprint of 1 mm×1 mm×1.65 mm is used. Due to the physical properties of the sensors and human vision system limitations, different image-processing algorithms, such as noise reduction, demosaicking, and gamma correction, among others, are needed to faithfully reproduce the image or video. A full image-processing pipeline is implemented using a field-programmable gate array (FPGA) to accomplish a high frame rate of 60 fps with minimum processing delay. Along with this, a viewer has also been developed to display and control the image-processing pipeline. The control and data transfer are done by a USB 3.0 end point in the computer. The full developed system achieves real-time processing of the image and fits in a Xilinx Spartan-6LX150 FPGA.
Turker, Yasemin; Aydin, Leyla Yilmaz; Baltaci, Davut; Erdem, Ozgur; Tanriverdi, Mehmet Halis; Sarigüzel, Yunus; Alasan, Fatih
2014-01-01
Family physicians (FPs) are cornerstone for tobacco control. It was aimed to compare the effect of training on their smoking cessation practice, knowledge level and attitudes towards smoking and tobacco control. The cross-sectional and multi-centered study was carried out using structured survey modified WHO based questionnaire. It was delivered to 1500 FPs randomly selected among approximately 23000 family physicians across the country. The study survey was self-reported by FPs, assessing their knowledge, attitudes, status of post-graduate training, and practice about tobacco control. Participants were assigned into two groups as non-trainee groups (Group 1) and post-graduate trainee (Group 2). The mean age was 38.4 ± 7.1 years-old. The percentage of male and female FPs in the study was 53.1% and 46.9%. The ratio of family physicians who participated in training program Group 2) was 26.5% (n = 327). The ratio of female FPs who participated the SCP training course was significantly higher than that of male FPs (27.3% versus 22.5%, p = 0.035). There was no significant difference for smoking status between groups (p = 0.686). When the number FPs whose consulted by the smokers over ≥ 5 a week was compared, the ratio of FPs was significantly higher in group 2 than group 1 (p < 0.001), but overall ratio of FPs (2.8%) who consulted within a week smokers was considerably lower Statements of Competence and confidence items stated by all FPs were 24.2% and 32.2%, respectively. Physicians who had attended post-graduate training on SCP were more competent and confident, compared to non-trained FPs (p = 0.002 and p = 0.001). Post-graduate training on tobacco control improved self-confidence and competence of FPs. With post-graduate training, significant improvement was seen in practical skills of physicians. A continuing training program should be introduced to FPs, to engage them for smoking cessation practice.
Frame synchronization methods based on channel symbol measurements
NASA Technical Reports Server (NTRS)
Dolinar, S.; Cheung, K.-M.
1989-01-01
The current DSN frame synchronization procedure is based on monitoring the decoded bit stream for the appearance of a sync marker sequence that is transmitted once every data frame. The possibility of obtaining frame synchronization by processing the raw received channel symbols rather than the decoded bits is explored. Performance results are derived for three channel symbol sync methods, and these are compared with results for decoded bit sync methods reported elsewhere. It is shown that each class of methods has advantages or disadvantages under different assumptions on the frame length, the global acquisition strategy, and the desired measure of acquisition timeliness. It is shown that the sync statistics based on decoded bits are superior to the statistics based on channel symbols, if the desired operating region utilizes a probability of miss many orders of magnitude higher than the probability of false alarm. This operating point is applicable for very large frame lengths and minimal frame-to-frame verification strategy. On the other hand, the statistics based on channel symbols are superior if the desired operating point has a miss probability only a few orders of magnitude greater than the false alarm probability. This happens for small frames or when frame-to-frame verifications are required.
NASA Astrophysics Data System (ADS)
Bari, Vlasta; Marchi, Andrea; De Maria, Beatrice; Rossato, Gianluca; Nollo, Giandomenico; Faes, Luca; Porta, Alberto
2016-05-01
Cardiovascular and cerebrovascular regulatory systems are vital control mechanisms responsible for guaranteeing homeostasis and are affected by respiration. This work proposes the investigation of cardiovascular and cerebrovascular control systems and the nonlinear influences of respiration on both regulations through joint symbolic analysis (JSA), conditioned or unconditioned on respiration. Interactions between cardiovascular and cerebrovascular regulatory systems were evaluated as well by performing correlation analysis between JSA indexes describing the two control systems. Heart period, systolic and mean arterial pressure, mean cerebral blood flow velocity and respiration were acquired on a beat-to-beat basis in 13 subjects experiencing recurrent syncope episodes (SYNC) and 13 healthy individuals (non-SYNC) in supine resting condition and during head-up tilt test at 60° (TILT). Results showed that JSA distinguished conditions and groups, whereas time domain parameters detected only the effect of TILT. Respiration affected cardiovascular and cerebrovascular regulatory systems in a nonlinear way and was able to modulate the interactions between the two control systems with different outcome in non-SYNC and SYNC groups, thus suggesting that the analysis of the impact of respiration on cardiovascular and cerebrovascular regulatory systems might improve our understanding of the mechanisms underpinning the development of postural-related syncope.
Interactive genetic counseling role-play: a novel educational strategy for family physicians.
Blaine, Sean M; Carroll, June C; Rideout, Andrea L; Glendon, Gord; Meschino, Wendy; Shuman, Cheryl; Telner, Deanna; Van Iderstine, Natasha; Permaul, Joanne
2008-04-01
Family physicians (FPs) are increasingly involved in delivering genetic services. Familiarization with aspects of genetic counseling may enable FPs to help patients make informed choices. Exploration of interactive role-play as a means to raise FPs' awareness of the process and content of genetic counseling. FPs attending two large Canadian family medicine conferences in 2005 were eligible -- 93 participated. FPs discussed a case during a one-on-one session with a genetic counselor. Evaluation involved pre and post intervention questionnaires FPs' baseline genetic knowledge was self-rated as uniformly poor. Baseline confidence was highest in eliciting family history and providing psychosocial support and lowest in discussing risks/benefits of genetic testing and counseling process. Post-intervention, 80% of FPs had better appreciation of family history and 97% indicated this was an effective learning experience. Role-play with FPs is effective in raising awareness of the process and content of genetic counseling and may be applied to other health disciplines.
Cunha, Leonardo Provetti; Figueiredo, Evelyn Alvernaz; Araújo, Henrique Pereira; Costa-Cunha, Luciana Virgínia Ferreira; Costa, Carolina Ferreira; Neto, José de Melo Costa; Matos, Aline Mota Freitas; de Oliveira, Marise Machado; Bastos, Marcus Gomes; Monteiro, Mário Luiz Ribeiro
2018-01-01
To determine the level of agreement between trained family physicians (FPs), general ophthalmologists (GOs), and a retinal specialist (RS) in the assessment of non-mydriatic fundus retinography in screening for diabetic retinopathy (DR) in the primary health-care setting. 200 Diabetic patients were submitted to two-field non-mydriatic digital fundus camera. The images were examined by four trained FPs, two GOs, and one RS with regard to the diagnosis and severity of DR and the diagnosis of macular edema. The RS served as gold standard. Reliability and accuracy were determined with the kappa test and diagnostic measures. A total of 397 eyes of 200 patients were included. The mean age was 55.1 (±11.7) years, and 182 (91%) had type 2 diabetes. The mean levels of serum glucose and glycosylated hemoglobin A1c were 195.6 (±87.3) mg/dL and 8.9% (±2.1), respectively. DR was diagnosed in 166 eyes by the RS and in 114 and 182 eyes by GO 1 and GO 2 , respectively. For severity, DR was graded as proliferative in 8 eyes by the RS vs. 15 and 9 eyes by GO 1 and GO 2 , respectively. The agreement between the RS and the GOs was substantial for both DR diagnosis (GO 1 k = 0.65; GO 2 k = 0.74) and severity (GO 1 k = 0.60; GO 2 k = 0.71), and fair or moderate for macular edema (GO 1 k = 0.27; GO 2 k = 0.43). FP 1 , FP 2 , FP 3 , and FP 4 diagnosed DR in 108, 119, 163, and 117 eyes, respectively. The agreement between the RS and the FPs with regard to DR diagnosis was substantial (FP 2 k = 0.69; FP 3 k = 0.73; FP 4 k = 0.71) or moderate (FP 1 k = 0.56). As for DR severity, the agreement between the FPs and the RS was substantial (FP 2 k = 0.66; FP 3 k = 069; FP 4 k = 0.64) or moderate (FP 1 k = 0.51). Agreement between the FPs and the RS with regard to macular edema was fair (FP 1 k = 0.33; FP 2 k = 0.39; FP 3 k = 0.37) or moderate (FP 4 k = 0.51). Non-mydriatic fundus retinography was shown to be useful in DR screening in the primary health-care setting. FPs made assessments with good levels of agreement with an RS. Non-mydriatic fundus retinography associated with appropriate general physicians training is essential for the DR screening.
Metcalf, Olivia; Pammer, Kristen
2014-03-01
Putative cyber addictions are of significant interest. There remains little experimental research into excessive use of first person shooter (FPS) games, despite their global popularity. Moreover, the role between excessive gaming and impulsivity remains unclear, with previous research showing conflicting findings. The current study investigated performances on a number of neuropsychological tasks (go/no-go, continuous performance task, Iowa gambling task) and a trait measure of impulsivity for a group of regular FPS gamers (n=25), addicted FPS gamers (n=22), and controls (n=22). Gamers were classified using the Addiction-Engagement Questionnaire. Addicted FPS gamers had significantly higher levels of trait impulsivity on the Barratt Impulsiveness Scale compared to controls. Addicted FPS gamers also had significantly higher levels of disinhibition in a go/no-go task and inattention in a continuous performance task compared to controls, whereas the regular FPS gamers had better decision making on the Iowa gambling task compared to controls. The results indicate impulsivity is associated with FPS gaming addiction, comparable to pathological gambling. The relationship between impulsivity and excessive gaming may be unique to the FPS genre. Furthermore, regular FPS gaming may improve decision making ability.
NASA Astrophysics Data System (ADS)
Oskar Jaehnig, Karl; Stassun, Keivan; Tan, Jonathan C.; Covey, Kevin R.; Da Rio, Nicola
2016-01-01
We study the nature of stellar multiplicity in young stellar systems using the INfrared Spectroscopy of Young Nebulous Clusters (IN-SYNC) survey, carried out in SDSS III with the APOGEE spectrograph. Multi-epoch observations of thousands of low-mass stars in Orion A, NGC2264, NGC1333 and IC348 have been carried out, yielding H-band spectra with R=22,500 for sources with H<12 mag. Radial velocity sensitivities ~0.3 km/s can be achieved, depending on the spectral type of the star. We search the IN-SYNC radial velocity catalog to identify sources with radial velocity variations indicative of spectroscopically undetected companions, analyze their spectral properties and discuss the implications for the overall multiplicity of stellar populations in young, embedded star clusters.
An Experimental Study of the Structure of Turbulent Non-Premixed Jet Flames in Microgravity
NASA Astrophysics Data System (ADS)
Boxx, Isaac; Idicheria, Cherian; Clemens, Noel
2000-11-01
The aim of this work is to investigate the structure of transitional and turbulent non-premixed jet flames under microgravity conditions. The microgravity experiments are being conducted using a newly developed drop rig and the University of Texas 1.5 second drop tower. The rig itself measures 16”x33”x38” and contains a co-flowing round jet flame facility, flow control system, CCD camera, and data/image acquisition computer. These experiments are the first phase of a larger study being conducted at the NASA Glenn Research Center 2.2 second drop tower facility. The flames being studied include methane and propane round jet flames at jet exit Reynolds numbers as high as 10,000. The primary diagnostic technique employed is emission imaging of flame luminosity using a relatively high-speed (350 fps) CCD camera. The high-speed images are used to study flame height, flame tip dynamics and burnout characteristics. Results are compared to normal gravity experimental results obtained in the same apparatus.
Application of image converter camera to measure flame propagation in S. I. engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, A.; Ishii, K.; Sasaki, T.
1989-01-01
A combustion flame visualization system, for use as an engine diagnostics tool, was developed in order to evaluate combustion chamber shapes in the development stage of mass-produced spark ignition (S.I.) engines. The system consists of an image converter camera and a computer-aided image processing system. The system is capable of high speed photography (10,000 fps) at low intensity light (1,000 cd/m/sup 2/), and of real-time display of the raw images of combustion flames. By using this system, flame structure estimated from the brightness level on a photograph and direction of flame propagation in a mass-produced 4-valve engine were measured. Itmore » was observed that the difference in the structure and the propagation of the flame in the cases of 4-valve and quasi-2-valve combustion chambers, which has the same in the pressure diagram, were detected. The quasi-2-valve configuration was adopted in order to improve swirl intensity.« less
The role of family physicians in cancer care: perspectives of primary and specialty care providers
Easley, J.; Miedema, B.; O’Brien, M.A.; Carroll, J.; Manca, D.; Webster, F.; Grunfeld, E.
2017-01-01
Background Currently, the specific role of family physicians (fps) in the care of people with cancer is not well defined. Our goal was to explore physician perspectives and contextual factors related to the coordination of cancer care and the role of fps. Methods Using a constructivist grounded theory approach, we conducted telephone interviews with 58 primary and cancer specialist health care providers from across Canada. Results The participants—21 fps, 15 surgeons, 12 medical oncologists, 6 radiation oncologists, and 4 general practitioners in oncology—were asked to describe both the role that fps currently play and the role that, in their opinion, fps should play in the future care of cancer patients across the cancer continuum. Participants identified 3 key roles: coordinating cancer care, managing comorbidities, and providing psychosocial care to patients and their families. However, fps and specialists discussed many challenges that prevent fps from fully performing those roles: ■ The fps described communication problems resulting from not being kept “in the loop” because they weren’t copied on patient reports and also the lack of clearly defined roles for all the various health care providers involved in providing care to cancer patients.■ The specialists expressed concerns about a lack of patient access to fp care, leaving specialists to fill the care gaps. The fps and specialists both recommended additional training and education for fps in survivorship care, cancer screening, genetic testing, and new cancer treatments. Conclusions Better communication, more collaboration, and further education are needed to enhance the role of fps in the care of cancer patients. PMID:28490920
Joos, Stefanie; Musselmann, Berthold; Szecsenyi, Joachim
2011-01-01
More than two-thirds of patients in Germany use complementary and alternative medicine (CAM) provided either by physicians or non-medical practitioners (“Heilpraktiker”). There is little information about the number of family physicians (FPs) providing CAM. Given the widespread public interest in the use of CAM, this study aimed to ascertain the use of and attitude toward CAM among FPs in Germany. A postal questionnaire developed based on qualitatively derived data was sent to 3000 randomly selected FPs in Germany. A reminder letter including a postcard (containing a single question about CAM use in practice and reasons for non-particpation in the survey) was sent to all FPs who had not returned the questionnaire. Of the 3000 FPs, 1027 (34%) returned the questionnaire and 444 (15%) returned the postcard. Altogether, 886 of the 1471 responding FPs (60%) reported using CAM in their practice. A positive attitude toward CAM was indicated by 503 FPs (55%), a rather negative attitude by 127 FPs (14%). Chirotherapy, relaxation and neural therapy were rated as most beneficial CAM therapies by FPs, whereas neural therapy, phytotherapy and acupuncture were the most commonly used therapies in German family practices. This survey clearly demonstrates that CAM is highly valued by many FPs and is already making a substantial contribution to first-contact primary care in Germany. Therefore, education and research about CAM should be increased. Furthermore, with the provision of CAM by FPs, the role of non-medical CAM practitioners within the German healthcare system is to be questioned. PMID:19293252
24/7 security system: 60-FPS color EMCCD camera with integral human recognition
NASA Astrophysics Data System (ADS)
Vogelsong, T. L.; Boult, T. E.; Gardner, D. W.; Woodworth, R.; Johnson, R. C.; Heflin, B.
2007-04-01
An advanced surveillance/security system is being developed for unattended 24/7 image acquisition and automated detection, discrimination, and tracking of humans and vehicles. The low-light video camera incorporates an electron multiplying CCD sensor with a programmable on-chip gain of up to 1000:1, providing effective noise levels of less than 1 electron. The EMCCD camera operates in full color mode under sunlit and moonlit conditions, and monochrome under quarter-moonlight to overcast starlight illumination. Sixty frame per second operation and progressive scanning minimizes motion artifacts. The acquired image sequences are processed with FPGA-compatible real-time algorithms, to detect/localize/track targets and reject non-targets due to clutter under a broad range of illumination conditions and viewing angles. The object detectors that are used are trained from actual image data. Detectors have been developed and demonstrated for faces, upright humans, crawling humans, large animals, cars and trucks. Detection and tracking of targets too small for template-based detection is achieved. For face and vehicle targets the results of the detection are passed to secondary processing to extract recognition templates, which are then compared with a database for identification. When combined with pan-tilt-zoom (PTZ) optics, the resulting system provides a reliable wide-area 24/7 surveillance system that avoids the high life-cycle cost of infrared cameras and image intensifiers.
Oyama, M A; Solter, P F; Thorn, C L; Stern, J A
2017-06-01
An important aspect of heart failure is the progressive ineffectiveness of the salutary natriuretic peptide system and its secondary messenger, 3',5'-cyclic guanosine monophosphate (cGMP). In humans with acute heart failure, administration of exogenous natriuretic peptide is associated with improvement in clinical signs and reduction of cardiac filling pressures. This study aimed to determine the feasibility, tolerance, and safety of subcutaneous (SC) synthetic canine B-type natriuretic peptide (syncBNP) administration in dogs. Six privately owned dogs. Dogs were enrolled in a modified 3 + 3 phase I trial. Three dogs initially received doses of 2.5 and 5 μg/kg SC syncBNP followed by an additional three dogs dosed at 5 and 10 μg/kg. Hemodynamic monitoring was performed for 120 min after each injection. Blood and urine samples were collected at 45 and 120 min after injection of 5 μg/kg. Major adverse clinical events that would potentially halt testing were pre-defined. Four healthy dogs and two dogs with stage B1 mitral valve disease were recruited. Synthetic canine B-type natriuretic peptide was well tolerated at all doses. Synthetic canine B-type natriuretic peptide at 5 μg/kg significantly increased median plasma cGMP (baseline cGMP, 131.5 pmol/mL [range, 91.9-183.6 pmol/mL]; 45 min, 153.6 pmol/mL [140.3-214.3 pmol/mL]; 120 min, 192.7 pmol/mL [139.1-240.1 pmol/mL]; p=0.041). We report for the first time administration of syncBNP in privately owned dogs. Administration of SC syncBNP was feasible, well tolerated, safe, and increased plasma cGMP concentration. Further studies using exogenous syncBNP for treatment of heart disease are warranted. Copyright © 2017 Elsevier B.V. All rights reserved.
Oliinyk, Olena S.; Chernov, Konstantin G.
2017-01-01
Bacterial photoreceptors absorb light energy and transform it into intracellular signals that regulate metabolism. Bacterial phytochrome photoreceptors (BphPs), some cyanobacteriochromes (CBCRs) and allophycocyanins (APCs) possess the near-infrared (NIR) absorbance spectra that make them promising molecular templates to design NIR fluorescent proteins (FPs) and biosensors for studies in mammalian cells and whole animals. Here, we review structures, photochemical properties and molecular functions of several families of bacterial photoreceptors. We next analyze molecular evolution approaches to develop NIR FPs and biosensors. We then discuss phenotypes of current BphP-based NIR FPs and compare them with FPs derived from CBCRs and APCs. Lastly, we overview imaging applications of NIR FPs in live cells and in vivo. Our review provides guidelines for selection of existing NIR FPs, as well as engineering approaches to develop NIR FPs from the novel natural templates such as CBCRs. PMID:28771184
CERNBox + EOS: end-user storage for science
NASA Astrophysics Data System (ADS)
Mascetti, L.; Gonzalez Labrador, H.; Lamanna, M.; Mościcki, JT; Peters, AJ
2015-12-01
CERNBox is a cloud synchronisation service for end-users: it allows syncing and sharing files on all major mobile and desktop platforms (Linux, Windows, MacOSX, Android, iOS) aiming to provide offline availability to any data stored in the CERN EOS infrastructure. The successful beta phase of the service confirmed the high demand in the community for an easily accessible cloud storage solution such as CERNBox. Integration of the CERNBox service with the EOS storage back-end is the next step towards providing “sync and share” capabilities for scientific and engineering use-cases. In this report we will present lessons learnt in offering the CERNBox service, key technical aspects of CERNBox/EOS integration and new, emerging usage possibilities. The latter includes the ongoing integration of “sync and share” capabilities with the LHC data analysis tools and transfer services.
The IATH ELAN Text-Sync Tool: A Simple System for Mobilizing ELAN Transcripts On- or Off-Line
ERIC Educational Resources Information Center
Dobrin, Lise M.; Ross, Douglas
2017-01-01
In this article we present the IATH ELAN Text-Sync Tool (ETST; see http://community.village.virginia.edu/etst), a series of scripts and workflow for playing ELAN files and associated audiovisual media in a web browser either on- or off-line. ELAN has become an indispensable part of documentary linguists' toolkit, but it is less than ideal for…
Unsteady motion of laser ablation plume by vortex induced by the expansion of curved shock wave
NASA Astrophysics Data System (ADS)
Tran, D. T.; Mori, K.
2017-02-01
There are a number of industrial applications of laser ablation in a gas atmosphere. When an intense pulsed laser beam is irradiated on a solid surface in the gas atmosphere, the surface material is ablated and expands into the atmosphere. At the same time, a spherical shock wave is launched by the ablation jet to induce the unsteady flow around the target surface. The ablated materials, luminously working as tracer, exhibit strange unsteady motions depending on the experimental conditions. By using a high-speed video camera (HPV-X2), unsteady motion ablated materials are visualized at the frame rate more than 106 fps, and qualitatively characterized.
Analysis of straw row in the image to control the trajectory of the agricultural combine harvester
NASA Astrophysics Data System (ADS)
Shkanaev, Aleksandr Yurievich; Polevoy, Dmitry Valerevich; Panchenko, Aleksei Vladimirovich; Krokhina, Darya Alekseevna; Nailevish, Sadekov Rinat
2018-04-01
The paper proposes a solution to the automatic operation of the combine harvester along the straw rows by means of the images from the camera, installed in the cab of the harvester. The U-Net is used to recognize straw rows in the image. The edges of the row are approximated in the segmented image by the curved lines and further converted into the harvester coordinate system for the automatic operating system. The "new" network architecture and approaches to the row approximation has improved the quality of the recognition task and the processing speed of the frames up to 96% and 7.5 fps, respectively. Keywords: Grain harvester,
Who is driving continuing medical education for family medicine?
Klein, Douglas; Allan, G Michael; Manca, Donna; Sargeant, Joan; Barnett, Carly
2009-01-01
Considerable time and money are invested in continuing medical education (CME) for family physicians (FPs) but the effectiveness is uncertain. The participation of FPs as coordinators and teachers is not well known. The goal of this project was to describe the role of FPs in organizing and teaching CME events that are accredited for FPs. Information about accredited CME events occurring in Alberta and Nova Scotia was requested from universities, provincial chapters of the College of Family Physicians of Canada, and pharmaceutical companies. Location, coordinating site, organizing committee members, teaching faculty, and format were recorded from each event. The number and proportion of FPs involved in both organizing and teaching CME events accredited for FPs were calculated and compared. A total of 314 CME events were collected, comprising a total of 1,472 hours of CME. From the CME events collected, there were 1,730 organizing committee members and 1,647 teachers. FPs constitute 59% of the organizing committees and 17% of the teachers. Significant differences in the numbers of FP planners and teachers were related to organizing group, format, location, and expected audience composition. The accreditation requirement for FPs on organizing committees likely helps preserve a reasonable proportion of FP organizers but not teachers in FP CME. The proportions of true FP planners and teachers may actually be lower than planning documents indicate. Low level of family physician teachers in CME may be due to FPs' not selecting FP teachers, the FP teaching pool's being inadequate, or the organizing committee's being unaware of FPs who are knowledgeable in particular areas.
Tan, N C; Tay, I H; Ngoh, A; Tan, M
2009-03-01
Little is known about the decision pathway that family physicians (FP) take in considering drug therapy for their asthma patients. This study aimed to explore the factors that influence FPs' decisions in prescribing medications for their asthma patients. A qualitative method using focus group discussions (FGD) was used to gather qualitative data based on a semi-structured topic guide from FPs of different training backgrounds and practices. 29 Singapore FPs working as private general practitioners (GP), polyclinic doctors and locums were recruited into five FGDs. The FPs' asthma drug prescription decisions were related to the FPs' medical training and acquisition of asthma-related information and updates. Uncertainty of disease diagnosis, patients' beliefs and their perceptions of the disease and treatment, as well as the FPs' concerns about drug side effects, were significant considerations for the participants. Costs related to differential subsidies in the consultation fees and drugs between public polyclinics and GP clinics in the local primary healthcare system, was a key factor in influencing the FPs' asthma drug treatment decisions. FPs' asthma drug prescribing behaviour is influenced by their medical training, disease definition, patient factors and drug costs in the context of the local primary healthcare system and policy.
Kosteniuk, Julie; Morgan, Debra; Innes, Anthea; Keady, John; Stewart, Norma; D'Arcy, Carl; Kirk, Andrew
2014-01-01
Little is known about the views of rural family physicians (FPs) regarding collaborative care models for patients with dementia. The study aims were to explore FPs' views regarding this issue, their role in providing dementia care, and the implications of providing dementia care in a rural setting. This study employed an exploratory qualitative design with a sample of 15 FPs. All rural FPs indicated acceptance of collaborative models. The main disadvantages of practicing rural were accessing urban-based health care and related services and a shortage of local health care resources. The primary benefit of practicing rural was FPs' social proximity to patients, families, and some health care workers. Rural FPs provided care for patients with dementia that took into account the emotional and practical needs of caregivers and families. FPs described positive and negative implications of rural dementia care, and all were receptive to models of care that included other health care professionals.
Concept of electro-optical sensor module for sniper detection system
NASA Astrophysics Data System (ADS)
Trzaskawka, Piotr; Dulski, Rafal; Kastek, Mariusz
2010-10-01
The paper presents an initial concept of the electro-optical sensor unit for sniper detection purposes. This unit, comprising of thermal and daylight cameras, can operate as a standalone device but its primary application is a multi-sensor sniper and shot detection system. Being a part of a larger system it should contribute to greater overall system efficiency and lower false alarm rate thanks to data and sensor fusion techniques. Additionally, it is expected to provide some pre-shot detection capabilities. Generally acoustic (or radar) systems used for shot detection offer only "after-the-shot" information and they cannot prevent enemy attack, which in case of a skilled sniper opponent usually means trouble. The passive imaging sensors presented in this paper, together with active systems detecting pointed optics, are capable of detecting specific shooter signatures or at least the presence of suspected objects in the vicinity. The proposed sensor unit use thermal camera as a primary sniper and shot detection tool. The basic camera parameters such as focal plane array size and type, focal length and aperture were chosen on the basis of assumed tactical characteristics of the system (mainly detection range) and current technology level. In order to provide costeffective solution the commercially available daylight camera modules and infrared focal plane arrays were tested, including fast cooled infrared array modules capable of 1000 fps image acquisition rate. The daylight camera operates as a support, providing corresponding visual image, easier to comprehend for a human operator. The initial assumptions concerning sensor operation were verified during laboratory and field test and some example shot recording sequences are presented.
Development of low-cost high-performance multispectral camera system at Banpil
NASA Astrophysics Data System (ADS)
Oduor, Patrick; Mizuno, Genki; Olah, Robert; Dutta, Achyut K.
2014-05-01
Banpil Photonics (Banpil) has developed a low-cost high-performance multispectral camera system for Visible to Short- Wave Infrared (VIS-SWIR) imaging for the most demanding high-sensitivity and high-speed military, commercial and industrial applications. The 640x512 pixel InGaAs uncooled camera system is designed to provide a compact, smallform factor to within a cubic inch, high sensitivity needing less than 100 electrons, high dynamic range exceeding 190 dB, high-frame rates greater than 1000 frames per second (FPS) at full resolution, and low power consumption below 1W. This is practically all the feature benefits highly desirable in military imaging applications to expand deployment to every warfighter, while also maintaining a low-cost structure demanded for scaling into commercial markets. This paper describes Banpil's development of the camera system including the features of the image sensor with an innovation integrating advanced digital electronics functionality, which has made the confluence of high-performance capabilities on the same imaging platform practical at low cost. It discusses the strategies employed including innovations of the key components (e.g. focal plane array (FPA) and Read-Out Integrated Circuitry (ROIC)) within our control while maintaining a fabless model, and strategic collaboration with partners to attain additional cost reductions on optics, electronics, and packaging. We highlight the challenges and potential opportunities for further cost reductions to achieve a goal of a sub-$1000 uncooled high-performance camera system. Finally, a brief overview of emerging military, commercial and industrial applications that will benefit from this high performance imaging system and their forecast cost structure is presented.
Maulfair, D D; Heinrichs, A J
2013-05-01
Ration sorting is thought to affect ruminal fermentation in such a manner that milk yield milk and components are often decreased. However, the influence of ruminally degradable starch on ration sorting has not been studied. Therefore, the objective of this experiment was to evaluate the interactions between forage particle size (FPS) and ruminally fermentable carbohydrates (RFC) for dry matter intake (DMI), ration sorting, ruminal fermentation, chewing activity, and milk yield and components. In this study, 12 (8 ruminally cannulated) multiparous, lactating Holstein cows were fed a total mixed ration that varied in FPS and RFC. Two lengths of corn silage were used to alter FPS and 2 grind sizes of corn grain were used to alter RFC. It was determined that increasing RFC increased ruminating time and did not affect eating time, whereas increasing FPS increased eating time and did not affect ruminating time. Ruminal fermentation did not differ by altering either FPS or RFC. However, increasing FPS tended to increase mean and maximum ruminal pH and increasing RFC tended to decrease minimum ruminal pH. Particle size distribution became more diverse and neutral detergent fiber content of refusals increased over time, whereas starch content decreased, indicating that cows were sorting against physically effective neutral detergent fiber and for RFC. Selection indices determined that virtually no interactions occurred between FPS and RFC and that despite significant sorting throughout the day, by 24h after feeding cows had consumed a ration very similar to what was offered. This theory was reinforced by particle fraction intakes that very closely resembled the proportions of particle fractions in the offered total mixed ration. An interaction between FPS and RFC was observed for DMI, as DMI decreased with increasing FPS when the diet included low RFC and did not change when the diet included high RFC. Dry matter intake increased with RFC for long diets and did not change with RFC on short diets. Increasing RFC was found to increase milk yield, milk protein content and yield, and lactose content and yield but decrease milk fat content. Increasing FPS did not have as great an effect on milk production as RFC. This study found no significant interaction between FPS and RFC for ration sorting, although an interaction between FPS and RFC for DMI was observed. Neither FPS nor RFC affected ruminal fermentation, whereas RFC had a greater influence on milk yield and components than FPS. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Lopes-Andrade, Cristiano; Grebennikov, Vasily V
2015-08-25
We report the first record of the beetle tribe Xylographellini (Ciidae) from the continental Palaearctic Region, represented by five new species discovered in Yunnan and Sichuan provinces, China: Scolytocis danae sp. nov., Syncosmetus euryale sp. nov., Sync. medusa sp. nov., Sync. perseus sp. nov. and Sync. stheno sp. nov. Illustrations and identification keys are provided for these new species, and in order to facilitate further research of Ciidae we present an open-access DNA barcode library (dx.doi.org/10.5883/DS-SYNCOSM) containing 114 records (of 44 species in 14 genera), 15 of which belong to the newly described species. A phylogenetic analysis based on the barcode fragment of the cytochrome oxidase I gene did not recover much tree structure within Ciidae, however both Xylographus Mellié and Syncosmetus Sharp were recovered as clades, with a single Scolytocis Blair being the sister to the latter.
Monocular Stereo Measurement Using High-Speed Catadioptric Tracking
Hu, Shaopeng; Matsumoto, Yuji; Takaki, Takeshi; Ishii, Idaku
2017-01-01
This paper presents a novel concept of real-time catadioptric stereo tracking using a single ultrafast mirror-drive pan-tilt active vision system that can simultaneously switch between hundreds of different views in a second. By accelerating video-shooting, computation, and actuation at the millisecond-granularity level for time-division multithreaded processing in ultrafast gaze control, the active vision system can function virtually as two or more tracking cameras with different views. It enables a single active vision system to act as virtual left and right pan-tilt cameras that can simultaneously shoot a pair of stereo images for the same object to be observed at arbitrary viewpoints by switching the direction of the mirrors of the active vision system frame by frame. We developed a monocular galvano-mirror-based stereo tracking system that can switch between 500 different views in a second, and it functions as a catadioptric active stereo with left and right pan-tilt tracking cameras that can virtually capture 8-bit color 512×512 images each operating at 250 fps to mechanically track a fast-moving object with a sufficient parallax for accurate 3D measurement. Several tracking experiments for moving objects in 3D space are described to demonstrate the performance of our monocular stereo tracking system. PMID:28792483
Ranade, Manisha K; Lynch, Bart D; Li, Jonathan G; Dempsey, James F
2006-01-01
We have developed an electronic portal imaging device (EPID) employing a fast scintillator and a high-speed camera. The device is designed to accurately and independently characterize the fluence delivered by a linear accelerator during intensity modulated radiation therapy (IMRT) with either step-and-shoot or dynamic multileaf collimator (MLC) delivery. Our aim is to accurately obtain the beam shape and fluence of all segments delivered during IMRT, in order to study the nature of discrepancies between the plan and the delivered doses. A commercial high-speed camera was combined with a terbium-doped gadolinium-oxy-sulfide (Gd2O2S:Tb) scintillator to form an EPID for the unaliased capture of two-dimensional fluence distributions of each beam in an IMRT delivery. The high speed EPID was synchronized to the accelerator pulse-forming network and gated to capture every possible pulse emitted from the accelerator, with an approximate frame rate of 360 frames-per-second (fps). A 62-segment beam from a head-and-neck IMRT treatment plan requiring 68 s to deliver was recorded with our high speed EPID producing approximately 6 Gbytes of imaging data. The EPID data were compared with the MLC instruction files and the MLC controller log files. The frames were binned to provide a frame rate of 72 fps with a signal-to-noise ratio that was sufficient to resolve leaf positions and segment fluence. The fractional fluence from the log files and EPID data agreed well. An ambiguity in the motion of the MLC during beam on was resolved. The log files reported leaf motions at the end of 33 of the 42 segments, while the EPID observed leaf motions in only 7 of the 42 segments. The static IMRT segment shapes observed by the high speed EPID were in good agreement with the shapes reported in the log files. The leaf motions observed during beam-on for step-and-shoot delivery were not temporally resolved by the log files.
Real-time imaging of methane gas leaks using a single-pixel camera.
Gibson, Graham M; Sun, Baoqing; Edgar, Matthew P; Phillips, David B; Hempler, Nils; Maker, Gareth T; Malcolm, Graeme P A; Padgett, Miles J
2017-02-20
We demonstrate a camera which can image methane gas at video rates, using only a single-pixel detector and structured illumination. The light source is an infrared laser diode operating at 1.651μm tuned to an absorption line of methane gas. The light is structured using an addressable micromirror array to pattern the laser output with a sequence of Hadamard masks. The resulting backscattered light is recorded using a single-pixel InGaAs detector which provides a measure of the correlation between the projected patterns and the gas distribution in the scene. Knowledge of this correlation and the patterns allows an image to be reconstructed of the gas in the scene. For the application of locating gas leaks the frame rate of the camera is of primary importance, which in this case is inversely proportional to the square of the linear resolution. Here we demonstrate gas imaging at ~25 fps while using 256 mask patterns (corresponding to an image resolution of 16×16). To aid the task of locating the source of the gas emission, we overlay an upsampled and smoothed image of the low-resolution gas image onto a high-resolution color image of the scene, recorded using a standard CMOS camera. We demonstrate for an illumination of only 5mW across the field-of-view imaging of a methane gas leak of ~0.2 litres/minute from a distance of ~1 metre.
Network-linked long-time recording high-speed video camera system
NASA Astrophysics Data System (ADS)
Kimura, Seiji; Tsuji, Masataka
2001-04-01
This paper describes a network-oriented, long-recording-time high-speed digital video camera system that utilizes an HDD (Hard Disk Drive) as a recording medium. Semiconductor memories (DRAM, etc.) are the most common image data recording media with existing high-speed digital video cameras. They are extensively used because of their advantage of high-speed writing and reading of picture data. The drawback is that their recording time is limited to only several seconds because the data amount is very large. A recording time of several seconds is sufficient for many applications. However, a much longer recording time is required in some applications where an exact prediction of trigger timing is hard to make. In the Late years, the recording density of the HDD has been dramatically improved, which has attracted more attention to its value as a long-recording-time medium. We conceived an idea that we would be able to build a compact system that makes possible a long time recording if the HDD can be used as a memory unit for high-speed digital image recording. However, the data rate of such a system, capable of recording 640 X 480 pixel resolution pictures at 500 frames per second (fps) with 8-bit grayscale is 153.6 Mbyte/sec., and is way beyond the writing speed of the commonly used HDD. So, we developed a dedicated image compression system and verified its capability to lower the data rate from the digital camera to match the HDD writing rate.
Modular Multi-Sensor Display System Design Study. Volume 2. Detail Design and Application Analysis
1974-08-01
control grid . 2. Horizontal AFC/Deflection Module - Generates horizontal sweep signals from input syncs to provide 525 to 1023 line television raster...separation, and gener- ate composite blanking for the CRT control grid . Signal Number of Lines Signal Type Characteristics Input Interface Composite...SEPERATOR DC RESTORA- TION l_i BLANKING VERT DRIVE ■♦ Bl" CRT " CATHODE * _fc> BRIGHTNESS ^ (FRONT PANEL) .CRT GRID ■♦• COMP SYNC Figure
Miniature multichannel biotelemeter system
NASA Technical Reports Server (NTRS)
Carraway, J. B.; Sumida, J. T. (Inventor)
1974-01-01
A miniature multichannel biotelemeter system is described. The system includes a transmitter where signals from different sources are sampled to produce a wavetrain of pulses. The transmitter also separates signals by sync pulses. The pulses amplitude modulate a radio frequency carrier which is received at a receiver unit. There the sync pulses are detected by a demultiplexer which routes the pulses from each different source to a separate output channel where the pulses are used to reconstruct the signals from the particular source.
Kajikawa, Yoshinao; Schroeder, Charles E
2015-01-01
Field potentials (FPs) recorded within the brain, often called "local field potentials" (LFPs), are useful measures of net synaptic activity in a neuronal ensemble. However, due to volume conduction, FPs spread beyond regions of underlying synaptic activity, and thus an "LFP" signal may not accurately reflect the temporal patterns of synaptic activity in the immediately surrounding neuron population. To better understand the physiological processes reflected in FPs, we explored the relationship between the FP and its membrane current generators using current source density (CSD) analysis in conjunction with a volume conductor model. The model provides a quantitative description of the spatiotemporal summation of immediate local and more distant membrane currents to produce the FP. By applying the model to FPs in the macaque auditory cortex, we have investigated a critical issue that has broad implications for FP research. We have shown that FP responses in particular cortical layers are differentially susceptible to activity in other layers. Activity in the supragranular layers has the strongest contribution to FPs in other cortical layers, and infragranular FPs are most susceptible to contributions from other layers. To define the physiological processes generating FPs recorded in loci of relatively weak synaptic activity, strong effects produced by synaptic events in the vicinity have to be taken into account. While outlining limitations and caveats inherent to FP measurements, our results also suggest specific peak and frequency band components of FPs can be related to activity in specific cortical layers. These results may help improving the interpretability of FPs. Copyright © 2015 the American Physiological Society.
Schroeder, Charles E.
2014-01-01
Field potentials (FPs) recorded within the brain, often called “local field potentials” (LFPs), are useful measures of net synaptic activity in a neuronal ensemble. However, due to volume conduction, FPs spread beyond regions of underlying synaptic activity, and thus an “LFP” signal may not accurately reflect the temporal patterns of synaptic activity in the immediately surrounding neuron population. To better understand the physiological processes reflected in FPs, we explored the relationship between the FP and its membrane current generators using current source density (CSD) analysis in conjunction with a volume conductor model. The model provides a quantitative description of the spatiotemporal summation of immediate local and more distant membrane currents to produce the FP. By applying the model to FPs in the macaque auditory cortex, we have investigated a critical issue that has broad implications for FP research. We have shown that FP responses in particular cortical layers are differentially susceptible to activity in other layers. Activity in the supragranular layers has the strongest contribution to FPs in other cortical layers, and infragranular FPs are most susceptible to contributions from other layers. To define the physiological processes generating FPs recorded in loci of relatively weak synaptic activity, strong effects produced by synaptic events in the vicinity have to be taken into account. While outlining limitations and caveats inherent to FP measurements, our results also suggest specific peak and frequency band components of FPs can be related to activity in specific cortical layers. These results may help improving the interpretability of FPs. PMID:25274348
Regnaut, Océane; Jeu-Steenhouwer, Marie; Manaouil, Cécile; Gignon, Maxime
2015-10-30
Family physicians (FPs) have a central role in the detection and management of child abuse. According to the literature, only 2-5% of initial reports of child abuse come from the medical profession. The objective of this study was to assess levels of knowledge of risk factors for child abuse by Family Physicians (FPs) and the attention that the physicians pay to these risk factors. We conducted a mixed-method survey based on semi-structured interviews. 50 FPs practicing in the Somme County (northern France) were interviewed with closed and open questions. The FPs' level of knowledge of risk factors for child abuse and obstacles in the detection of child abuse were assessed. The FPs' level of knowledge of risk factors for child abuse was similar to that reported in the literature. However, FPs knew little about the significant role of prematurity. Likewise, the FP's training did not seem to influence their knowledge of risk factors. Fear of an incorrect diagnosis was the main obstacle to reporting a suspected case. The FPs considered that they were often alone in dealing with a difficult situation and considered that the judicial system and the social services were not sufficiently active. Few FPs had actually received specific training in the detection and management of child abuse but many stated their need for this type of training. FPs encounter many obstacles in the detection of child abuse, which sometimes make the FP reluctant to report a suspected or potential case. Medical education need to be improved in this field.
Mastracchio during EMU FPS Remove and Replace OPS
2014-04-14
Expedition 39 flight engineer Rick Mastracchio poses for a photo with the replacement Fan Pump Separator (FPS) and Extravehicular Mobility Unit (EMU) 3005. Image was taken in the Quest Airlock (A/L) during FPS remove and replace operations.
Bari, Vlasta; De Maria, Beatrice; Mazzucco, Claudio Enrico; Rossato, Gianluca; Tonon, Davide; Nollo, Giandomenico; Faes, Luca; Porta, Alberto
2017-05-01
A model-based conditional transfer entropy approach was exploited to quantify the information transfer in cerebrovascular (CBV) and cardiovascular (CV) systems in subjects prone to develop postural syncope. Spontaneous beat-to-beat variations of mean cerebral blood flow velocity (MCBFV) derived from a transcranial Doppler device, heart period (HP) derived from surface electrocardiogram, mean arterial pressure (MAP) and systolic arterial pressure (SAP) derived from finger plethysmographic arterial pressure device were monitored at rest in supine position (REST) and during 60° head-up tilt (TILT) in 13 individuals (age mean ± standard deviation: 28 ± 9 years, min-max range: 18-44 years, 5 males) with a history of recurrent episodes of syncope (SYNC) and in 13 age- and gender-matched controls (NonSYNC). Respiration (R) obtained from a thoracic belt was acquired as well and considered as a conditioning signal in transfer entropy assessment. Synchronous sequences of 250 consecutive MCBFV, HP, MAP, SAP and R values were utilized to estimate the information genuinely transferred from MAP to MCBFV (i.e. disambiguated from R influences) and vice versa. Analogous indexes were computed from SAP to HP and vice versa. Traditional time and frequency domain analyses were carried out as well. SYNC subjects showed an increased genuine information transfer from MAP to MCBFV during TILT, while they did not exhibit the expected rise of the genuine information transfer from SAP to HP. We conclude that SYNC individuals featured an impaired cerebral autoregulation visible during TILT and were unable to activate cardiac baroreflex to cope with the postural challenge. Traditional frequency domain markers based on transfer function modulus, phase and coherence functions were less powerful or less specific in typifying the CBV and CV controls of SYNC individuals. Conditional transfer entropy approach can identify the impairment of CBV and CV controls and provide specific clues to identify subjects prone to develop postural syncope.
Clements, Mark A; Staggs, Vincent S
2017-05-01
Many individuals with type 1 diabetes (T1D) upload and review blood glucose data between clinic visits. Mobile phone applications that receive data from a "connected" glucometer and that support pattern management are available and have the capacity to make data upload and review less burdensome. Whether mobile apps can improve diabetes self-management among individuals with type 1 diabetes remains unknown. We analyzed retrospective data on 81 youths with T1D who were trained to use a glucometer-connected mobile app in their self-management. To assess the effect of glucometer synchronization ("sync") rate on hemoglobin A1c (HbA1c), mean blood glucose (mBG), and daily frequency of SMBG, we regressed those clinical outcomes on the frequency of glucometer syncs with the mobile app after controlling for other clinical care variables. Median age was 14.0 (IQR 10.4-15.9) years, median duration of diabetes was 4.9 (2.7, 7.5) years, and median baseline HbA1c was 8.6% (7.9, 9.8). The sample was 49% male and 86% white. Youths with T1D synchronized glucometer data with the mobile app an average of 0.22 times per week (range 0-2.25). The glucometer sync rate did not have a statistically significant association with HbA1c or mean BG; in contrast, data sync frequency was associated with the frequency of self-monitoring of blood glucose (SMBG) such that each additional sync was associated with a 2.3-fold increase in SMBG frequency ( P < .01). A glucometer-connected mobile app may increase an individual's engagement with other aspects of care (eg, SMBG frequency). Whether diabetes device-connected mobile apps can improve glycemic control remains to be determined.
Fission Power System Technology for NASA Exploration Missions
NASA Technical Reports Server (NTRS)
Mason, Lee; Houts, Michael
2011-01-01
Under the NASA Exploration Technology Development Program, and in partnership with the Department of Energy (DOE), NASA is conducting a project to mature Fission Power System (FPS) technology. A primary project goal is to develop viable system options to support future NASA mission needs for nuclear power. The main FPS project objectives are as follows: 1) Develop FPS concepts that meet expected NASA mission power requirements at reasonable cost with added benefits over other options. 2) Establish a hardware-based technical foundation for FPS design concepts and reduce overall development risk. 3) Reduce the cost uncertainties for FPS and establish greater credibility for flight system cost estimates. 4) Generate the key products to allow NASA decisionmakers to consider FPS as a preferred option for flight development. In order to achieve these goals, the FPS project has two main thrusts: concept definition and risk reduction. Under concept definition, NASA and DOE are performing trade studies, defining requirements, developing analytical tools, and formulating system concepts. A typical FPS consists of the reactor, shield, power conversion, heat rejection, and power management and distribution (PMAD). Studies are performed to identify the desired design parameters for each subsystem that allow the system to meet the requirements with reasonable cost and development risk. Risk reduction provides the means to evaluate technologies in a laboratory test environment. Non-nuclear hardware prototypes are built and tested to verify performance expectations, gain operating experience, and resolve design uncertainties.
Family physician workloads and access to care in Winnipeg: 1991 to 2001.
Watson, Diane E; Katz, Alan; Reid, Robert J; Bogdanovic, Bogdan; Roos, Noralou; Heppner, Petra
2004-08-17
Current perceptions of family physician (FP) shortages in Canada have prompted policies to expand medical schools. Our objective was to assess how FP supply, workloads and access to care have changed over the past decade. We used an anonymized physician and population registry and administrative health service data from Winnipeg for the period 1991/92 to 2000/01. We calculated the following measures of supply and workload: ratios of FPs to population, of population to FPs and of FP full-time equivalents (FTEs) to population, as well as FP activity ratios (sum of FTEs/number of FPs), annual number of visits per FP and visits per FP per full-time day of work. Trends in FP remuneration were analyzed by age and sex. We also measured standardized visit rates and stratified the analysis by populations deemed at risk of needing FP services. In 2000/01 FPs between 30 and 49 years of age (64% of the workforce) provided 20% fewer visits per year than their same-age peers did 10 years previously. Conversely, FPs 60 to 69 years of age (11% of the workforce) provided 33% more visits per year than the corresponding group a decade earlier. On a per capita basis, the number of FPs declined by 5%, from 97 per 100 000 population in 1991/92 to 92 per 100 000 population in 2000/01, which paralleled changes in national estimates of FP supply. Per capita visit rates among Winnipeg citizens (3.5 per year in 2000/01) and average workloads among FPs (4193 visits per year in 2000/01) were stable over the decade. Despite relative homeostasis in aggregate FP supply and use, there have been substantial temporal shifts in the volume of services provided by FPs of different age groups. Younger FPs are providing many fewer visits and older FPs are providing many more visits than their same-age predecessors did 10 years ago, a finding that was independent of physician sex. Given these data, the perpetual focus of policy-makers and care providers on increasing numbers of FPs will not help in diagnosing or treating issues of supply, workloads and access to care.
MPCM: a hardware coder for super slow motion video sequences
NASA Astrophysics Data System (ADS)
Alcocer, Estefanía; López-Granado, Otoniel; Gutierrez, Roberto; Malumbres, Manuel P.
2013-12-01
In the last decade, the improvements in VLSI levels and image sensor technologies have led to a frenetic rush to provide image sensors with higher resolutions and faster frame rates. As a result, video devices were designed to capture real-time video at high-resolution formats with frame rates reaching 1,000 fps and beyond. These ultrahigh-speed video cameras are widely used in scientific and industrial applications, such as car crash tests, combustion research, materials research and testing, fluid dynamics, and flow visualization that demand real-time video capturing at extremely high frame rates with high-definition formats. Therefore, data storage capability, communication bandwidth, processing time, and power consumption are critical parameters that should be carefully considered in their design. In this paper, we propose a fast FPGA implementation of a simple codec called modulo-pulse code modulation (MPCM) which is able to reduce the bandwidth requirements up to 1.7 times at the same image quality when compared with PCM coding. This allows current high-speed cameras to capture in a continuous manner through a 40-Gbit Ethernet point-to-point access.
Clustering method for counting passengers getting in a bus with single camera
NASA Astrophysics Data System (ADS)
Yang, Tao; Zhang, Yanning; Shao, Dapei; Li, Ying
2010-03-01
Automatic counting of passengers is very important for both business and security applications. We present a single-camera-based vision system that is able to count passengers in a highly crowded situation at the entrance of a traffic bus. The unique characteristics of the proposed system include, First, a novel feature-point-tracking- and online clustering-based passenger counting framework, which performs much better than those of background-modeling-and foreground-blob-tracking-based methods. Second, a simple and highly accurate clustering algorithm is developed that projects the high-dimensional feature point trajectories into a 2-D feature space by their appearance and disappearance times and counts the number of people through online clustering. Finally, all test video sequences in the experiment are captured from a real traffic bus in Shanghai, China. The results show that the system can process two 320×240 video sequences at a frame rate of 25 fps simultaneously, and can count passengers reliably in various difficult scenarios with complex interaction and occlusion among people. The method achieves high accuracy rates up to 96.5%.
Design of a compact low-power human-computer interaction equipment for hand motion
NASA Astrophysics Data System (ADS)
Wu, Xianwei; Jin, Wenguang
2017-01-01
Human-Computer Interaction (HCI) raises demand of convenience, endurance, responsiveness and naturalness. This paper describes a design of a compact wearable low-power HCI equipment applied to gesture recognition. System combines multi-mode sense signals: the vision sense signal and the motion sense signal, and the equipment is equipped with the depth camera and the motion sensor. The dimension (40 mm × 30 mm) and structure is compact and portable after tight integration. System is built on a module layered framework, which contributes to real-time collection (60 fps), process and transmission via synchronous confusion with asynchronous concurrent collection and wireless Blue 4.0 transmission. To minimize equipment's energy consumption, system makes use of low-power components, managing peripheral state dynamically, switching into idle mode intelligently, pulse-width modulation (PWM) of the NIR LEDs of the depth camera and algorithm optimization by the motion sensor. To test this equipment's function and performance, a gesture recognition algorithm is applied to system. As the result presents, general energy consumption could be as low as 0.5 W.
Primary prevention of cardiovascular diseases: a cost study in family practices.
de Bekker-Grob, Esther W; van Dulmen, Sandra; van den Berg, Matthijs; Verheij, Robert A; Slobbe, Laurentius C J
2011-07-06
Considering the scarcity of health care resources and the high costs associated with cardiovascular diseases, we investigated the spending on cardiovascular primary preventive activities and the prescribing behaviour of primary preventive cardiovascular medication (PPCM) in Dutch family practices (FPs). A mixed methods design was used, which consisted of a questionnaire (n = 80 FPs), video recordings of hypertension- or cholesterol-related general practitioner visits (n = 56), and the database of Netherlands Information Network of General Practice (n = 45 FPs; n = 157,137 patients). The questionnaire and video recordings were used to determine the average frequency and time spent on cardiovascular primary preventive activities per FP respectively. Taking into account the annual income and full time equivalents of general practitioners, health care assistants, and practice nurses as well as the practice costs, the total spending on cardiovascular primary preventive activities in Dutch FPs was calculated. The database of Netherlands Information Network of General Practice was used to determine the prescribing behaviour in Dutch FPs by conducting multilevel regression models and adjusting for patient and practice characteristics. Total expenditure on cardiovascular primary preventive activities in FPs in 2009 was €38.8 million (€2.35 per capita), of which 47% was spent on blood pressure measurements, 26% on cardiovascular risk profiling, and 11% on lifestyle counselling. Fifteen percent (€11 per capita) of all cardiovascular medication prescribed in FPs was a PPCM. FPs differed greatly on prescription of PPCM (odds ratio of 3.1). Total costs of cardiovascular primary preventive activities in FPs such as blood pressure measurements and lifestyle counselling are relatively low compared to the costs of PPCM. There is considerable heterogeneity in prescribing behaviour of PPCM between FPs. Further research is needed to determine whether such large differences in prescription rates are justified. Striving for an optimal use of cardiovascular primary preventive activities might lead to similar health outcomes, but may achieve important cost savings.
Modin, Sonja; Törnkvist, Lena; Furhoff, Anna-Karin; Hylander, Ingrid
2010-10-27
This article concerns Swedish family physicians' (FPs) experiences collaborating with district nurses (DNs) when the DNs provide medical treatment for home care patients. The aim was to develop a model to illuminate this process from the FPs' perspective. Semi-structured interviews were conducted with 13 FPs concerning one of their patients with home care by a DN. The interview focused on one patient's treatment and care by different care providers and the collaboration among them. Grounded theory methodology (GTM) was used in the analyses. It was essential for FPs to collaborate with and rely on DNs in the medical treatment of home care patients. According to the FPs, factors such as the disease, FPs' working conditions and attitude determined how much of the initiative in this treatment FPs retained or left to DNs. Depending on the circumstances, two different roles were adopted by the individual FPs: medical conductors who retain the initiative and medical consultants who leave the initiative to DNs. Factors as the disease, DNs' attitudes towards collaboration and DNs' working conditions influenced whether or not the FPs felt that grounds for relying on DNs were satisfactory. Regardless of the role of the FP, conditions for medical treatment were judged by the FPs to be good enough when the grounds for relying on the DN were satisfactory and problematic when they were not. In the role of conductor, the FP will identify when the grounds for relying on the DN are unsatisfactory and be able to take action, but in the role of consultant the FP will not detect this, leaving home care patients without appropriate support. Only when there are satisfactory grounds for relying on the DN, will conditions for providing home care medical treatment be good enough when the FP adopts a consultative role.
Travagliati, Marco; Girardo, Salvatore; Pisignano, Dario; Beltram, Fabio; Cecchini, Marco
2013-09-03
Spatiotemporal image correlation spectroscopy (STICS) is a simple and powerful technique, well established as a tool to probe protein dynamics in cells. Recently, its potential as a tool to map velocity fields in lab-on-a-chip systems was discussed. However, the lack of studies on its performance has prevented its use for microfluidics applications. Here, we systematically and quantitatively explore STICS microvelocimetry in microfluidic devices. We exploit a simple experimental setup, based on a standard bright-field inverted microscope (no fluorescence required) and a high-fps camera, and apply STICS to map liquid flow in polydimethylsiloxane (PDMS) microchannels. Our data demonstrates optimal 2D velocimetry up to 10 mm/s flow and spatial resolution down to 5 μm.
The application of high-speed cinematography for the quantitative analysis of equine locomotion.
Fredricson, I; Drevemo, S; Dalin, G; Hjertën, G; Björne, K
1980-04-01
Locomotive disorders constitute a serious problem in horse racing which will only be rectified by a better understanding of the causative factors associated with disturbances of gait. This study describes a system for the quantitative analysis of the locomotion of horses at speed. The method is based on high-speed cinematography with a semi-automatic system of analysis of the films. The recordings are made with a 16 mm high-speed camera run at 500 frames per second (fps) and the films are analysed by special film-reading equipment and a mini-computer. The time and linear gait variables are presented in tabular form and the angles and trajectories of the joints and body segments are presented graphically.
Dendrites fragmentation induced by oscillating cavitation bubbles in ultrasound field.
Wang, S; Kang, J; Zhang, X; Guo, Z
2018-02-01
The fragmentation of the dendrites of succinonitrile (SCN)-2-wt.% acetone organic transparent alloy caused by ultrasound-induced cavitation bubbles was studied by using ultra-high-speed digital camera with a rate of 40,000fps. Real-time imaging reveals that the vibrating cavitation bubbles can fragment not only secondary arms but also the primary ones under high ultrasound power. The secondary arms always broke at their roots as a result of stress concentration induced by oscillated cavitation bubble and then ripped off from their primary arms. Generally the fragment process takes tens of milliseconds from bending to breaking, while the break always occurs immediately in less than 25μs. Copyright © 2017. Published by Elsevier B.V.
Word and frame synchronization with verification for PPM optical communications
NASA Technical Reports Server (NTRS)
Marshall, William K.
1986-01-01
A method for obtaining word and frame synchronization in pulse position modulated optical communication systems is described. The method uses a short sync sequence inserted at the beginning of each data frame and a verification procedure to distinguish between inserted and randomly occurring sequences at the receiver. This results in an easy to implement sync system which provides reliable synchronization even at high symbol error rates. Results are given for the application of this approach to a highly energy efficient 256-ary PPM test system.
Perreault, Kadija; Pineault, Raynald; Da Silva, Roxane Borgès; Provost, Sylvie; Feldman, Debbie E
2017-09-01
To assess the degree of collaboration in primary health care organizations between FPs and other health care professionals; and to identify organizational factors associated with such collaboration. Cross-sectional survey. Primary health care organizations in the Montreal and Monteregie regions of Quebec. Physicians or administrative managers from 376 organizations. Degree of collaboration between FPs and other specialists and between FPs and nonphysician health professionals. Almost half (47.1%) of organizations reported a high degree of collaboration between FPs and other specialists, but a high degree of collaboration was considerably less common between FPs and nonphysician professionals (16.5%). Clinic collaboration with a hospital and having more patients with at least 1 chronic disease were associated with higher FP collaboration with other specialists. The proportion of patients with at least 1 chronic disease was the only factor associated with collaboration between FPs and nonphysician professionals. There is room for improvement regarding interprofessional collaboration in primary health care, especially between FPs and nonphysician professionals. Organizations that manage patients with more chronic diseases collaborate more with both non-FP specialists and nonphysician professionals. Copyright© the College of Family Physicians of Canada.
What can organizations do to improve family physicians’ interprofessional collaboration?
Perreault, Kadija; Pineault, Raynald; Da Silva, Roxane Borgès; Provost, Sylvie; Feldman, Debbie E.
2017-01-01
Abstract Objective To assess the degree of collaboration in primary health care organizations between FPs and other health care professionals; and to identify organizational factors associated with such collaboration. Design Cross-sectional survey. Setting Primary health care organizations in the Montreal and Monteregie regions of Quebec. Participants Physicians or administrative managers from 376 organizations. Main outcome measures Degree of collaboration between FPs and other specialists and between FPs and nonphysician health professionals. Results Almost half (47.1%) of organizations reported a high degree of collaboration between FPs and other specialists, but a high degree of collaboration was considerably less common between FPs and nonphysician professionals (16.5%). Clinic collaboration with a hospital and having more patients with at least 1 chronic disease were associated with higher FP collaboration with other specialists. The proportion of patients with at least 1 chronic disease was the only factor associated with collaboration between FPs and nonphysician professionals. Conclusion There is room for improvement regarding interprofessional collaboration in primary health care, especially between FPs and nonphysician professionals. Organizations that manage patients with more chronic diseases collaborate more with both non-FP specialists and nonphysician professionals. PMID:28904048
A Review of Fluorescent Proteins for Use in Yeast.
Bialecka-Fornal, Maja; Makushok, Tatyana; Rafelski, Susanne M
2016-01-01
The field of fluorescent proteins (FPs) is constantly developing. The use of FPs changed the field of life sciences completely, starting a new era of direct observation and quantification of cellular processes. The broad spectrum of FPs (see Fig. 1) with a wide range of characteristics allows their use in many different experiments. This review discusses the use of FPs for imaging in budding yeast (Saccharomyces cerevisiae) and fission yeast Schizosaccharomyces pombe). The information included in this review is relevant for both species unless stated otherwise.
Keleshis, C; Ionita, CN; Yadava, G; Patel, V; Bednarek, DR; Hoffmann, KR; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873) PMID:18836570
Keleshis, C; Ionita, Cn; Yadava, G; Patel, V; Bednarek, Dr; Hoffmann, Kr; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873).
Gender inequalities in COPD decision-making in primary care.
Delgado, Ana; Saletti-Cuesta, Lorena; López-Fernández, Luis Andrés; Gil-Garrido, Natalia; Luna Del Castillo, Juan de Dios
2016-05-01
COPD is a frequent severe illness that increasingly affects females. Gender inequalities have been reported in COPD care. To analyze decision-making in primary care for men and women with identical COPD as a function of the gender of the family physician (FP). Cross-sectional, multicenter study in 457 Andalusian FPs, using a self-administered vignette-based questionnaire on COPD featuring a male or female patient, with four variables on clinical reasoning: "tobacco as most important risk factor (RF)", "ordering of spirometry", "COPD as most likely diagnosis", and "referral". Multilevel logistic regression analysis. Response rate was 67.4% (308/457). In analysis of the four FP gender-patient gender dyads, tobacco was more frequently considered as priority RF for the man than for the woman in the vignette by female (95.6%vs.67.1%) and male (79.8%vs.62.5%) FPs. COPD was more frequently the most likely diagnosis for the man versus woman by female (84.4%vs.49.9%) and male (78.5%vs.57.8%) FPs. Male FPs more frequently ordered spirometry for the man versus woman (68.1%vs.46.8%). There were no differences in referral between male and female patients. Male FPs were more likely than female FPs to consider tobacco as priority RF for the man (p = 002). Female FPs were more likely than male FPs to refer the man (22.5%vs.8%). There may be gender inequalities in primary care for COPD in our setting. Diagnostic and therapeutic efforts appear lower in female patients. Male and female FPs only differed in care of the male patient, indicating FP gender-patient gender interaction. Copyright © 2016 Elsevier Ltd. All rights reserved.
Enzensberger, Christian; Achterberg, Friederike; Graupner, Oliver; Wolter, Aline; Herrmann, Johannes; Axt-Fliedner, Roland
2017-06-01
Frame rates (FR) used for strain analysis assessed by speckle tracking in fetal echocardiography show a considerable variation. The aim of this study was to investigate the influence of the FR on strain analysis in 2D speckle tracking. Fetal echocardiography was performed prospectively on a Toshiba Aplio 500 system and a Toshiba Artida system, respectively. Based on an apical or basal four-chamber view of the fetal heart, cine loops were stored with a FR of 30 fps (Aplio 500) and 60 fps (Artida/Aplio 500). For both groups (30fps and 60fps), global and segmental longitudinal peak systolic strain (LPSS) values of both, left (LV) and right ventricle (RV), were assessed by 2D wall-motion tracking. A total of 101 fetuses, distributed to three study groups, were included. The mean gestational age was 25.2±5.0 weeks. Mean global LPSS values for RV in the 30 fps group and in the 60 fps group were -16.07% and -16.47%, respectively. Mean global LPSS values for LV in the 30 fps group and in the 60 fps group were -17.54% and -17.06%, respectively. Comparing global and segmental LPSS values of both, the RV and LV, did not show any statistically significant differences within the two groups. Performance of myocardial 2D strain analysis by wall-motion tracking was feasible with 30 and 60 fps. Obtained global and segmental LPSS values of both ventricles were relatively independent from acquisition rate. © 2017, Wiley Periodicals, Inc.
Wei, Na; Xu, Haiqing; Kim, Soo Rin
2013-01-01
Accumulation of xylitol in xylose fermentation with engineered Saccharomyces cerevisiae presents a major problem that hampers economically feasible production of biofuels from cellulosic plant biomass. In particular, substantial production of xylitol due to unbalanced redox cofactor usage by xylose reductase (XR) and xylitol dehydrogenase (XDH) leads to low yields of ethanol. While previous research focused on manipulating intracellular enzymatic reactions to improve xylose metabolism, this study demonstrated a new strategy to reduce xylitol formation and increase carbon flux toward target products by controlling the process of xylitol secretion. Using xylitol-producing S. cerevisiae strains expressing XR only, we determined the role of aquaglyceroporin Fps1p in xylitol export by characterizing extracellular and intracellular xylitol. In addition, when FPS1 was deleted in a poorly xylose-fermenting strain with unbalanced XR and XDH activities, the xylitol yield was decreased by 71% and the ethanol yield was substantially increased by nearly four times. Experiments with our optimized xylose-fermenting strain also showed that FPS1 deletion reduced xylitol production by 21% to 30% and increased ethanol yields by 3% to 10% under various fermentation conditions. Deletion of FPS1 decreased the xylose consumption rate under anaerobic conditions, but the effect was not significant in fermentation at high cell density. Deletion of FPS1 resulted in higher intracellular xylitol concentrations but did not significantly change the intracellular NAD+/NADH ratio in xylose-fermenting strains. The results demonstrate that Fps1p is involved in xylitol export in S. cerevisiae and present a new gene deletion target, FPS1, and a mechanism different from those previously reported to engineer yeast for improved xylose fermentation. PMID:23475614
NASA Astrophysics Data System (ADS)
Belcher, Anna; Manno, Clara; Ward, Peter; Henson, Stephanie A.; Sanders, Richard; Tarling, Geraint A.
2017-03-01
The faecal pellets (FPs) of zooplankton can be important vehicles for the transfer of particulate organic carbon (POC) to the deep ocean, often making large contributions to carbon sequestration. However, the routes by which these FPs reach the deep ocean have yet to be fully resolved. We address this by comparing estimates of copepod FP production to measurements of copepod FP size, shape, and number in the upper mesopelagic (175-205 m) using Marine Snow Catchers, and in the bathypelagic using sediment traps (1500-2000 m). The study is focussed on the Scotia Sea, which contains some of the most productive regions in the Southern Ocean, where epipelagic FP production is likely to be high. We found that, although the size distribution of the copepod community suggests that high numbers of small FPs are produced in the epipelagic, small FPs are rare in the deeper layers, implying that they are not transferred efficiently to depth. Consequently, small FPs make only a minor contribution to FP fluxes in the meso- and bathypelagic, particularly in terms of carbon. The dominant FPs in the upper mesopelagic were cylindrical and elliptical, while ovoid FPs were dominant in the bathypelagic. The change in FP morphology, as well as size distribution, points to the repacking of surface FPs in the mesopelagic and in situ production in the lower meso- and bathypelagic, which may be augmented by inputs of FPs via zooplankton vertical migrations. The flux of carbon to the deeper layers within the Southern Ocean is therefore strongly modulated by meso- and bathypelagic zooplankton, meaning that the community structure in these zones has a major impact on the efficiency of FP transfer to depth.
Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second
NASA Astrophysics Data System (ADS)
Zuo, Chao; Tao, Tianyang; Feng, Shijie; Huang, Lei; Asundi, Anand; Chen, Qian
2018-03-01
Fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time, we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.
Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Chao; Tao, Tianyang; Feng, Shijie
We report that fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time,more » we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Lastly, based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.« less
Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second
Zuo, Chao; Tao, Tianyang; Feng, Shijie; ...
2017-11-06
We report that fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time,more » we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Lastly, based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.« less
Exposure of men to intermittent photic stimulation under simulated IFR conditions.
DOT National Transportation Integrated Search
1966-10-01
Ten men were subjected to intermittent photic stimulation in an airplane cockpit in an environmental chamber by (1) a Grimes red rotating beacon (1.5 FPS), (2) an Air Guard strobe light (1.0 FPS) and (3) propeller flicker (10 FPS). IFR conditions wer...
En route air traffic controllers' use of flight progress strips : a graph-theoretic analysis.
DOT National Transportation Integrated Search
1992-11-01
In the United States, flight data are represented on a paper Flight Progress Strip (FPS). The role of the FPS has recently attracted attention because of plans to automate this aspect of air traffic control. The communication activities and FPS activ...
Design of the Trigger Interface and Distribution Board for CEBAF 12 GeV Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gu, Jianhui; Dong, Hai; Cuevas, R
The design of the Trigger Interface and Distribution (TID) board for the 12 GeV Upgrade at the Continuous Electron Beam Accelerator Facility (CEBAF) at TJNAL is described. The TID board distributes a low jitter system clock, synchronized trigger, and synchronized multi-purpose SYNC signal. The TID also initiates data acquisition for the crate. With the TID boards, a multi-crate system can be setup for experiment test and commissioning. The TID board can be selectively populated as a Trigger Interface (TI) board, or a Trigger Distribution (TD) board for the 12 GeV upgrade experiments. When the TID is populated as a TI,more » it can be located in the VXS crate and distribute the CLOCK/TRIGGER/SYNC through the VXS P0 connector; it can also be located in the standard VME64 crate, and distribute the CLOCK/TRIGGER/SYNC through the VME P2 connector or front panel. It initiates the data acquisition for the front crate where the TI is positioned in. When the TID is populated as a TD, it fans out the CLOCK/TRIGGER/SYNC from trigger supervisor to the front end crates through optical fibres. The TD monitors the trigger processing on the TIs, and gives feedback to the TS for trigger flow control. Field Programmable Gate Arrays (FPGA) is utilised on TID board to provide programmability. The TID boards were intensively tested on the bench, and various setups.« less
77 FR 37687 - Assistance to Firefighters Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... importance of mitigation activities, the FY 2012 FP&S will be allocated $35 million for grants. The FP&S... grants supporting eligible fire prevention activities and research and development activities that...,250) of AFG Program funds for the FP&S Grant Program. However, due to the importance of mitigation...
Effects of oral administration of titanium dioxide fine-sized particles on plasma glucose in mice.
Gu, Ning; Hu, Hailong; Guo, Qian; Jin, Sanli; Wang, Changlin; Oh, Yuri; Feng, Yujie; Wu, Qiong
2015-12-01
Titanium dioxide (TiO2) is an authorized additive used as a food colorant, is composed of nano-sized particles (NP) and fine-sized particles (FP). Previous study reported that oral administration of TiO2 NPs triggers an increase in plasma glucose of mice. However, no previous studies have focused on toxic effects of TiO2 FPs on plasma glucose homeostasis following oral administration. In the current study, mice were orally administered TiO2 FPs greater than 100 nm in size (64 mg/kg body weight per day), and effects on plasma glucose levels examined. Our results showed that titanium levels was not changed in mouse blood, livers and pancreases after mice were orally administered TiO2 FPs. Biochemical analyzes showed that plasma glucose and ROS levels were not affected by TiO2 FPs. Histopathological results showed that TiO2 FPs did not induce pathology changes in organs, especially plasma glucose homeostasis regulation organs, such as pancreas and liver. Western blotting showed that oral administration of TiO2 FPs did not induce insulin resistance (IR) in mouse liver. These results showed that, TiO2 FPs cannot be absorbed via oral administration and affect plasma glucose levels in mice. Copyright © 2015 Elsevier Ltd. All rights reserved.
Family physician workloads and access to care in Winnipeg: 1991 to 2001
Watson, Diane E.; Katz, Alan; Reid, Robert J.; Bogdanovic, Bogdan; Roos, Noralou; Heppner, Petra
2004-01-01
Background Current perceptions of family physician (FP) shortages in Canada have prompted policies to expand medical schools. Our objective was to assess how FP supply, workloads and access to care have changed over the past decade. Methods We used an anonymized physician and population registry and administrative health service data from Winnipeg for the period 1991/92 to 2000/01. We calculated the following measures of supply and workload: ratios of FPs to population, of population to FPs and of FP full-time equivalents (FTEs) to population, as well as FP activity ratios (sum of FTEs/number of FPs), annual number of visits per FP and visits per FP per full-time day of work. Trends in FP remuneration were analyzed by age and sex. We also measured standardized visit rates and stratified the analysis by populations deemed at risk of needing FP services. Results In 2000/01 FPs between 30 and 49 years of age (64% of the workforce) provided 20% fewer visits per year than their same-age peers did 10 years previously. Conversely, FPs 60 to 69 years of age (11% of the workforce) provided 33% more visits per year than the corresponding group a decade earlier. On a per capita basis, the number of FPs declined by 5%, from 97 per 100 000 population in 1991/92 to 92 per 100 000 population in 2000/01, which paralleled changes in national estimates of FP supply. Per capita visit rates among Winnipeg citizens (3.5 per year in 2000/01) and average workloads among FPs (4193 visits per year in 2000/01) were stable over the decade. Interpretation Despite relative homeostasis in aggregate FP supply and use, there have been substantial temporal shifts in the volume of services provided by FPs of different age groups. Younger FPs are providing many fewer visits and older FPs are providing many more visits than their same-age predecessors did 10 years ago, a finding that was independent of physician sex. Given these data, the perpetual focus of policy-makers and care providers on increasing numbers of FPs will not help in diagnosing or treating issues of supply, workloads and access to care. PMID:15313992
NASA Astrophysics Data System (ADS)
Deng, Zhiwei; Li, Xicai; Shi, Junsheng; Huang, Xiaoqiao; Li, Feiyan
2018-01-01
Depth measurement is the most basic measurement in various machine vision, such as automatic driving, unmanned aerial vehicle (UAV), robot and so on. And it has a wide range of use. With the development of image processing technology and the improvement of hardware miniaturization and processing speed, real-time depth measurement using dual cameras has become a reality. In this paper, an embedded AM5728 and the ordinary low-cost dual camera is used as the hardware platform. The related algorithms of dual camera calibration, image matching and depth calculation have been studied and implemented on the hardware platform, and hardware design and the rationality of the related algorithms of the system are tested. The experimental results show that the system can realize simultaneous acquisition of binocular images, switching of left and right video sources, display of depth image and depth range. For images with a resolution of 640 × 480, the processing speed of the system can be up to 25 fps. The experimental results show that the optimal measurement range of the system is from 0.5 to 1.5 meter, and the relative error of the distance measurement is less than 5%. Compared with the PC, ARM11 and DMCU hardware platforms, the embedded AM5728 hardware is good at meeting real-time depth measurement requirements in ensuring the image resolution.
McKay, Sandra M; Maki, Brian E
2010-01-01
A computer-based 'Useful Field of View' (UFOV) training program has been shown to be effective in improving visual processing in older adults. Studies of young adults have shown that playing video games can have similar benefits; however, these studies involved realistic and violent 'first-person shooter' (FPS) games. The willingness of older adults to play such games has not been established. OBJECTIVES: To determine the degree to which older adults would accept playing a realistic, violent FPS-game, compared to video games not involving realistic depiction of violence. METHODS: Sixteen older adults (ages 64-77) viewed and rated video-clip demonstrations of the UFOV program and three video-game genres (realistic-FPS, cartoon-FPS, fixed-shooter), and were then given an opportunity to try them out (30 minutes per game) and rate various features. RESULTS: The results supported a hypothesis that the participants would be less willing to play the realistic-FPS game in comparison to the less violent alternatives (p's<0.02). After viewing the video-clip demonstrations, 10 of 16 participants indicated they would be unwilling to try out the realistic-FPS game. Of the six who were willing, three did not enjoy the experience and were not interested in playing again. In contrast, all 12 subjects who were willing to try the cartoon-FPS game reported that they enjoyed it and would be willing to play again. A high proportion also tried and enjoyed the UFOV training (15/16) and the fixed-shooter game (12/15). DISCUSSION: A realistic, violent FPS video game is unlikely to be an appropriate choice for older adults. Cartoon-FPS and fixed-shooter games are more viable options. Although most subjects also enjoyed UFOV training, a video-game approach has a number of potential advantages (for instance, 'addictive' properties, low cost, self-administration at home). We therefore conclude that non-violent cartoon-FPS and fixed-shooter video games warrant further investigation as an alternative to the UFOV program for training improved visual processing in seniors.
Why do family doctors prescribe potentially inappropriate medication to elderly patients?
Voigt, Karen; Gottschall, Mandy; Köberlein-Neu, Juliane; Schübel, Jeannine; Quint, Nadine; Bergmann, Antje
2016-07-22
Based on changes in pharmacokinetics and -dynamics in elderly patients, there are potentially inappropriate medications (PIM) that should be avoided in patients aged ≥ 65 years. Current studies showed prescription rates of PIM between 22.5 and 28.4 % in the primary care setting. The evidence concerning reasons for PIM prescription by FPs is limited. This mixed method study consisted of three research parts: 1) semi-standardized content analysis of patients' records, 2) qualitative interviews with FPs using a) open questions and b) selected patient-specific case vignettes and 3) qualitative interviews with FPs' medical assistants. The integration of qualitative interviews was used to explain the quantitative results (triangulation design). PIM were identified according to the German PRISCUS list. Descriptive and multivariate statistical analysis was done using SPSS 22.0. Qualitative content analysis of interviews was used to classify the content of the interviews for indicating pertinent categories. All data were pseudonymously recorded and analyzed. Content analysis of 1846 patients' records and interviews with 7 related FPs were conducted. Elderly patients [n = 1241, mean age: 76, females: 56.6 %] were characterized in average by 8.3 documented chronic diagnosis. 23.9 % of elderly patients received at least one PIM prescription. Sedatives/hypnotics were the most frequent prescribed PIM-drugs (13.7 %). Mental disorders, gender and number of long-term medication were detected as predictors for the probability of a PIM prescription. Common reported reasons for PIM prescription by FPs concerned limited knowledge regarding PIM, limited applicability of PIM lists in daily practice, lack of time, having no alternatives in medication, stronger patient-related factors than age that influence prescription, own bad experiences regarding changes of medication or refusal of following prescriptions of sedative/hypnotics. It is essential to see FPs in a complex decision making situation with several influencing factors on their prescribing, including: patient-oriented prioritization, FPs' experiences in daily practice, FPs' knowledge regarding existing recommendations and their trust in it and organizational characteristics of FPs' daily medical practice. These pros and cons of PIM prescription in elderly patients should be considered in FPs' advanced training.
Physician education on decision-making capacity assessment: Current state and future directions.
Charles, Lesley; Parmar, Jasneet; Brémault-Phillips, Suzette; Dobbs, Bonnie; Sacrey, Lori; Sluggett, Bryan
2017-01-01
To examine FPs' training needs for conducting decision-making capacity assessments (DMCAs) and to determine how training materials, based on a DMCA model, can be adapted for use by FPs. A scoping review of the literature and qualitative research methodology (focus groups and structured interviews). Edmonton, Alta. Nine FPs, who practised in various settings, who chose to attend a focus group on DMCAs. A scoping review of the literature to examine the current status of physician education regarding assessment of decision-making capacity, and a focus group and interviews with FPs to ascertain the educational needs of FPs in this area. Based on the scoping review of the literature, 4 main themes emerged: increasing saliency of DMCAs owing to an aging population, suboptimal DMCA training for physicians, inconsistent approaches to DMCA, and tension between autonomy and protection. The findings of the focus groups and interviews indicate that, while FPs working as independent practitioners or with interprofessional teams are motivated to engage in DMCAs and use the DMCA model for those assessments, several factors impede their conducting DMCAs. The most notable barriers were a lack of education, isolation from interprofessional teams, uneasiness around managing conflict with families, fear of liability, and concerns regarding remuneration. This pilot study has helped to inform ways to better train and support FPs in conducting DMCAs. Family physicians are well positioned, with proper training, to effectively conduct DMCAs. To engage FPs in the process, however, the barriers should be addressed. Copyright© the College of Family Physicians of Canada.
VizieR Online Data Catalog: IN-SYNC. III. Radial velocities of IC348 stars (Cottaar+, 2015)
NASA Astrophysics Data System (ADS)
Cottaar, M.; Covey, K. R.; Foster, J. B.; Meyer, M. R.; Tan, J. C.; Nidever, D. L.; Drew Chojnowski, S.; da Rio, N.; Flaherty, K. M.; Frinchaboy, P. M.; Majewski, S.; Skrutskie, M. F.; Wilson, J. C.; Zasowski, G.
2015-11-01
Cottaar et al. (Paper I, 2014, J/ApJ/794/125) describes the analysis of the high-resolution near-infrared spectra obtained by the APOGEE multi-object spectrograph from stars in IC 348, NGC 1333, NGC 2264, and Orion A as part of the INfrared Spectroscopy of Young Nebulous Clusters (IN-SYNC) ancillary program. Using radial velocities determined from APOGEE spectra of 380 likely cluster members, we have measured the radial velocity distribution of the young (2-6Myr) cluster IC 348. (2 data files).
Damani, Anuja; Ghoshal, Arunangshu; Dighe, Manjiri; Dhiliwal, Sunil; Muckaden, Maryann
2018-01-01
Patients with chronic life-limiting conditions on palliative care (PC) prefer to be treated at home. Medical care by family physicians (FPs) reduces demand on costly and busy hospital facilities. Working of PC team in collaboration with FPs is thus helpful in home-based management of patients. This study aimed at exploring the extent of knowledge of FPs about PC and the need for additional training. Semi-structured interviews were conducted with ten FPs from two suburbs of Mumbai, currently served by home care services of a tertiary cancer care center. Data were digitally recorded, transcribed, and analyzed using exploratory analysis followed by content analysis to develop thematic codes. FPs perceive PC as symptom control and psychological support helpful in managing patients with advanced life-limiting illnesses. Further training would help them in PC provision. Such training programs should preferably focus on symptom management and communication skills. There is a need for further research in designing a training module for FPs to get better understanding of the principles of PC.
Damani, Anuja; Ghoshal, Arunangshu; Dighe, Manjiri; Dhiliwal, Sunil; Muckaden, Maryann
2018-01-01
Context: Patients with chronic life-limiting conditions on palliative care (PC) prefer to be treated at home. Medical care by family physicians (FPs) reduces demand on costly and busy hospital facilities. Working of PC team in collaboration with FPs is thus helpful in home-based management of patients. Aims: This study aimed at exploring the extent of knowledge of FPs about PC and the need for additional training. Settings and Design: Semi-structured interviews were conducted with ten FPs from two suburbs of Mumbai, currently served by home care services of a tertiary cancer care center. Subjects and Methods: Data were digitally recorded, transcribed, and analyzed using exploratory analysis followed by content analysis to develop thematic codes. Results and Conclusions: FPs perceive PC as symptom control and psychological support helpful in managing patients with advanced life-limiting illnesses. Further training would help them in PC provision. Such training programs should preferably focus on symptom management and communication skills. There is a need for further research in designing a training module for FPs to get better understanding of the principles of PC. PMID:29736114
The modes of physician remuneration and their effect on direct patient contact.
Basu, Kisalaya; Mandelzys, David
2008-01-01
Initiatives such as primary care reform have allocated millions of dollars towards the Canadian health care system. The way physicians are remunerated affects the supply of physician services and as such is essential to these initiatives to facilitate policy goals. However, there exists a gap in understanding how different modes of remuneration affect physician-patient contact. This paper examines if there is a significant difference between the average full-time-equivalent (FTE) of family physicians (FPs) remunerated through fee-for-service (FFS), salary, and blended arrangements. We used Nova Scotia physician billings dataset which tracks every services performed by both FFS and salaried physicians over the fiscal year 2003 to 2004. We estimated two semi-logarithmic models to examine the relationship between (1) modes of remuneration and FTE, and (2) modes of remuneration and total services, using ordinary least squares method. The National Physician Survey shows a significant difference between the current modes of remuneration and the preferred modes of remuneration; thus ruling out the possibility of selectivity bias. The results show that compared to the FFS FPs, the salaried FPs and blended FPs produce on average 40.46% and 23.13% less FTE respectively. It also indicates that compared to the FFS FPs, the salaried FPs and blended FPs deliver 53.54% and 31.49% fewer services on average.
Khmelinskii, Anton; Meurer, Matthias; Ho, Chi-Ting; Besenbeck, Birgit; Füller, Julia; Lemberg, Marius K.; Bukau, Bernd; Mogk, Axel; Knop, Michael
2016-01-01
Tandem fluorescent protein timers (tFTs) report on protein age through time-dependent change in color, which can be exploited to study protein turnover and trafficking. Each tFT, composed of two fluorescent proteins (FPs) that differ in maturation kinetics, is suited to follow protein dynamics within a specific time range determined by the maturation rates of both FPs. So far, tFTs have been constructed by combining slower-maturing red fluorescent proteins (redFPs) with the faster-maturing superfolder green fluorescent protein (sfGFP). Toward a comprehensive characterization of tFTs, we compare here tFTs composed of different faster-maturing green fluorescent proteins (greenFPs) while keeping the slower-maturing redFP constant (mCherry). Our results indicate that the greenFP maturation kinetics influences the time range of a tFT. Moreover, we observe that commonly used greenFPs can partially withstand proteasomal degradation due to the stability of the FP fold, which results in accumulation of tFT fragments in the cell. Depending on the order of FPs in the timer, incomplete proteasomal degradation either shifts the time range of the tFT toward slower time scales or precludes its use for measurements of protein turnover. We identify greenFPs that are efficiently degraded by the proteasome and provide simple guidelines for the design of new tFTs. PMID:26609072
A survey to assess family physicians' motivation to teach undergraduates in their practices.
May, Marcus; Mand, Peter; Biertz, Frank; Hummers-Pradier, Eva; Kruschinski, Carsten
2012-01-01
In Germany, family physicians (FPs) are increasingly needed to participate in undergraduate medical education. Knowledge of FPs' motivation to teach medical students in their practices is lacking. To describe a novel questionnaire that assesses the motivation of FPs to teach undergraduates in their practices and to show the results of a subsequent survey using this instrument. The questionnaire was developed based on a review of the literature. Previously used empirical instruments assessing occupational values and motivation were included. A preliminary version was pretested in a pilot study. The resulting 68-item questionnaire was sent to 691 FPs involved in undergraduate medical education. Reliability was assessed and subgroups were analyzed with regard to differences in motivation. A total of 523 physicians in n = 458 teaching practices participated (response rate 75.7%). 'Helping others' and 'interest' were revealed as the predominant motives. Responses showed a predominantly intrinsic motivation of the participating FPs. Their main incentives were an ambition to work as a medical preceptor, to generally improve undergraduate education and to share knowledge. Material compensation was of minor importance. Time restraints were indicated as a barrier by some FPs, but were not a general concern. German FPs involved in medical education have altruistic attitudes towards teaching medical students in their practices. Motivational features give an important insight for the recruitment of FP preceptors as well as for their training in instructional methods.
dCache, Sync-and-Share for Big Data
NASA Astrophysics Data System (ADS)
Millar, AP; Fuhrmann, P.; Mkrtchyan, T.; Behrmann, G.; Bernardt, C.; Buchholz, Q.; Guelzow, V.; Litvintsev, D.; Schwank, K.; Rossi, A.; van der Reest, P.
2015-12-01
The availability of cheap, easy-to-use sync-and-share cloud services has split the scientific storage world into the traditional big data management systems and the very attractive sync-and-share services. With the former, the location of data is well understood while the latter is mostly operated in the Cloud, resulting in a rather complex legal situation. Beside legal issues, those two worlds have little overlap in user authentication and access protocols. While traditional storage technologies, popular in HEP, are based on X.509, cloud services and sync-and-share software technologies are generally based on username/password authentication or mechanisms like SAML or Open ID Connect. Similarly, data access models offered by both are somewhat different, with sync-and-share services often using proprietary protocols. As both approaches are very attractive, dCache.org developed a hybrid system, providing the best of both worlds. To avoid reinventing the wheel, dCache.org decided to embed another Open Source project: OwnCloud. This offers the required modern access capabilities but does not support the managed data functionality needed for large capacity data storage. With this hybrid system, scientists can share files and synchronize their data with laptops or mobile devices as easy as with any other cloud storage service. On top of this, the same data can be accessed via established mechanisms, like GridFTP to serve the Globus Transfer Service or the WLCG FTS3 tool, or the data can be made available to worker nodes or HPC applications via a mounted filesystem. As dCache provides a flexible authentication module, the same user can access its storage via different authentication mechanisms; e.g., X.509 and SAML. Additionally, users can specify the desired quality of service or trigger media transitions as necessary, thus tuning data access latency to the planned access profile. Such features are a natural consequence of using dCache. We will describe the design of the hybrid dCache/OwnCloud system, report on several months of operations experience running it at DESY, and elucidate the future road-map.
Method for targetless tracking subpixel in-plane movements.
Espinosa, Julian; Perez, Jorge; Ferrer, Belen; Mas, David
2015-09-01
We present a targetless motion tracking method for detecting planar movements with subpixel accuracy. This method is based on the computation and tracking of the intersection of two nonparallel straight-line segments in the image of a moving object in a scene. The method is simple and easy to implement because no complex structures have to be detected. It has been tested and validated using a lab experiment consisting of a vibrating object that was recorded with a high-speed camera working at 1000 fps. We managed to track displacements with an accuracy of hundredths of pixel or even of thousandths of pixel in the case of tracking harmonic vibrations. The method is widely applicable because it can be used for distance measuring amplitude and frequency of vibrations with a vision system.
Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC).
Phillips, Zachary F; Chen, Michael; Waller, Laura
2017-01-01
We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC), is a single-shot variant of Differential Phase Contrast (DPC), which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps) for various in vitro cell samples and c. elegans in a micro-fluidic channel.
Who Is Driving Continuing Medical Education for Family Medicine?
ERIC Educational Resources Information Center
Klein, Douglas; Allan, G. Michael; Manca, Donna; Sargeant, Joan; Barnett, Carly
2009-01-01
Introduction: Considerable time and money are invested in continuing medical education (CME) for family physicians (FPs) but the effectiveness is uncertain. The participation of FPs as coordinators and teachers is not well known. The goal of this project was to describe the role of FPs in organizing and teaching CME events that are accredited for…
What motivates family physicians to participate in training programs in shared decision making?
Allaire, Anne-Sophie; Labrecque, Michel; Giguere, Anik; Gagnon, Marie-Pierre; Légaré, France
2012-01-01
Little is known about the factors that influence family physician (FP) participation in continuing professional development (CPD) programs in shared decision making (SDM). We sought to identify the factors that motivate FPs to participate in DECISION+, a CPD program in SDM. In 2007-2008, we collected data from 39 FPs who participated in a pilot randomized trial of DECISION+. In 2010, we collected data again from 11 of those participants and from 12 new subjects. Based on the theory of planned behavior, our questionnaire assessed FPs' intentions to participate in a CPD program in SDM and evaluated FPs' attitudes, subjective norms and perceived behavioral control. We also conducted 4 focus groups to explore FPs' salient beliefs. In 2010, FPs' mean intention to participate in a CPD program in SDM was relatively strong (2.6 ± 0.5 on a scale from -3 = "strongly disagree" to +3 = "strongly agree"). Affective attitude was the only factor significantly associated with intention (r = .51, p = .04). FPs identified the attractions of participating in a CPD program in SDM as (1) its interest, (2) the pleasure of learning, and (3) professional stimulation. Facilitators of their participation were (1) a relevant clinical topic, (2) an interactive program, (3) an accessible program, and (4) decision support tools. To attract FPs to a CPD program in SDM, CPD developers should make the program interesting, enjoyable, and professionally stimulating. They should choose a clinically relevant topic, ensure that the program is interactive and accessible, and include decision support tools. Copyright © 2012 The Alliance for Continuing Education in the Health Professions, the Society for Academic Continuing Medical Education, and the Council on CME, Association for Hospital Medical Education.
ERIC Educational Resources Information Center
Allen, Michael; Ferrier, Suzanne; Sargeant, Joan; Loney, Elaine; Bethune, Graeme; Murphy, Gerard
2005-01-01
Caring for patients with dementia is complex and demanding. Since family physicians (FPs) provide much of this care, we examined their practices, learning needs, and barriers to care concerning Alzheimer's disease and other dementias. We surveyed 392 (approximately 50%) Nova Scotia FPs and conducted focus groups and interviews with: FPs; staff of…
Hong, Yan; Shen, Chao; Yin, Qingqing; Sun, Menghan; Ma, Yingjuan; Liu, Xueping
2016-05-01
An increased level of advanced glycation end products (AGEs) is observed in brains of patients with Alzheimer's disease (AD). AGEs and receptor for AGEs (RAGE) play important roles in the pathogenesis of AD. FPS-ZM1 is a high-affinity RAGE-specific blocker that inhibits amyloid-β binding to RAGE, neurological damage and inflammation in the APP(sw/0) transgenic mouse model of AD. FPS-ZM1 is not toxic to mice and can easily cross the blood-brain barrier. In this study, an AGEs-RAGE-activated rat model were established by intrahippocampal injection of AGEs, then these rats were treated with intraperitoneal administration of FPS-ZM1 and the possible neuroprotective effects were investigated. We found that AGEs administration induced an-regulation of Abeta production, inflammation, and oxidative stress, and an increased escape latency of rats in the Morris water maze test, all of these are significantly reduced by FPS-ZM1 treatment. Our results suggest that the AGEs-RAGE pathway is responsible for cognitive deficits, and therefore may be a potential treatment target. FPS-ZM1 might be a novel therapeutic agent to treat AD patients.
Improved Space Object Orbit Determination Using CMOS Detectors
NASA Astrophysics Data System (ADS)
Schildknecht, T.; Peltonen, J.; Sännti, T.; Silha, J.; Flohrer, T.
2014-09-01
CMOS-sensors, or in general Active Pixel Sensors (APS), are rapidly replacing CCDs in the consumer camera market. Due to significant technological advances during the past years these devices start to compete with CCDs also for demanding scientific imaging applications, in particular in the astronomy community. CMOS detectors offer a series of inherent advantages compared to CCDs, due to the structure of their basic pixel cells, which each contains their own amplifier and readout electronics. The most prominent advantages for space object observations are the extremely fast and flexible readout capabilities, feasibility for electronic shuttering and precise epoch registration, and the potential to perform image processing operations on-chip and in real-time. The major challenges and design drivers for ground-based and space-based optical observation strategies have been analyzed. CMOS detector characteristics were critically evaluated and compared with the established CCD technology, especially with respect to the above mentioned observations. Similarly, the desirable on-chip processing functionalities which would further enhance the object detection and image segmentation were identified. Finally, we simulated several observation scenarios for ground- and space-based sensor by assuming different observation and sensor properties. We will introduce the analyzed end-to-end simulations of the ground- and space-based strategies in order to investigate the orbit determination accuracy and its sensitivity which may result from different values for the frame-rate, pixel scale, astrometric and epoch registration accuracies. Two cases were simulated, a survey using a ground-based sensor to observe objects in LEO for surveillance applications, and a statistical survey with a space-based sensor orbiting in LEO observing small-size debris in LEO. The ground-based LEO survey uses a dynamical fence close to the Earth shadow a few hours after sunset. For the space-based scenario a sensor in a sun-synchronous LEO orbit, always pointing in the anti-sun direction to achieve optimum illumination conditions for small LEO debris, was simulated. For the space-based scenario the simulations showed a 20 130 % improvement of the accuracy of all orbital parameters when varying the frame rate from 1/3 fps, which is the fastest rate for a typical CCD detector, to 50 fps, which represents the highest rate of scientific CMOS cameras. Changing the epoch registration accuracy from a typical 20.0 ms for a mechanical shutter to 0.025 ms, the theoretical value for the electronic shutter of a CMOS camera, improved the orbit accuracy by 4 to 190 %. The ground-based scenario also benefit from the specific CMOS characteristics, but to a lesser extent.
Zmijan, Robert; Jonnalagadda, Umesh S.; Carugo, Dario; Kochi, Yu; Lemm, Elizabeth; Packham, Graham; Hill, Martyn
2015-01-01
We demonstrate an imaging flow cytometer that uses acoustic levitation to assemble cells and other particles into a sheet structure. This technique enables a high resolution, low noise CMOS camera to capture images of thousands of cells with each frame. While ultrasonic focussing has previously been demonstrated for 1D cytometry systems, extending the technology to a planar, much higher throughput format and integrating imaging is non-trivial, and represents a significant jump forward in capability, leading to diagnostic possibilities not achievable with current systems. A galvo mirror is used to track the images of the moving cells permitting exposure times of 10 ms at frame rates of 50 fps with motion blur of only a few pixels. At 80 fps, we demonstrate a throughput of 208 000 beads per second. We investigate the factors affecting motion blur and throughput, and demonstrate the system with fluorescent beads, leukaemia cells and a chondrocyte cell line. Cells require more time to reach the acoustic focus than beads, resulting in lower throughputs; however a longer device would remove this constraint. PMID:29456838
Tanifuji, M; Yamanaka, A; Sunaba, R; Terakawa, S; Toyama, K
1996-10-28
To characterize optical responses (ORs) evoked by white matter (WM) stimulation in slices of rat visual cortex (VC) stained with voltage sensitive dyes, time course of ORs in each layer was investigated by recording ORs with a linearly aligned photodiode array, and the spatial patterns of the ORs at specified time after stimulation were investigated by a CCD camera in combination with stroboscopic illumination. The ORs recorded by the photodiode array were an increase in absorption at 700 nm and a decrease in the wavelength below 650 nm, suggesting that the ORs were dye related. The ORs were compared with field potentials (FPs) to clarify that neural events were represented by the ORs, and in support of this view, we found that the first order spatial differentials of ORs and that of FPs were in good agreement. We further compared ORs with intracellular responses, and found that the ORs mainly represent postsynaptic potentials (PSPs) of VC neurons except for the deeper part of layer VI, where a component representing action potentials in fibers stimulated directly was observed. The time-lapse imaging of ORs showed that excitation first propagated vertically up to layer I and subsequently in the horizontal direction along layers II-III and V-VI as in previous investigations. Spatio-temporal patterns of ORs under blockade of synaptic transmission were also investigated to reveal activity of fibers evoked by WM stimulation which produced such patterns of propagation.
Family physicians and HIV infection.
Hall, N; Crochette, N; Blanchi, S; Lavoix, A; Billaud, E; Baron, C; Abgueguen, P; Perré, P; Rabier, V
2015-01-01
We aimed to describe the current and desired involvement of family physicians (FPs) in the treatment of HIV patients (screening practices, potential training and patient follow-up) to reduce the duration and frequency of their hospital treatment. We conducted a descriptive cross-sectional survey between 2011 and 2012 with the support of COREVIH (Regional Coordinating Committee on HIV). We sent a self-assessment questionnaire to all FPs of the Pays de la Loire region to enquire about their HIV screening practices and expectations for the management of HIV patients. A total of 871 FPs completed the questionnaire (response rate: 30.4%). A total of 54.2% said to provide care to HIV patients; the mean number of HIV patients per FP was estimated at 1.4. With regard to HIV screening, 12.2% systematically suggest an HIV serology to their patients and 72.7% always suggest it to pregnant women. About 45.4% of responding FPs said to be willing to manage HIV patients (clinical and biological monitoring, compliance checks and prescription renewal). FPs mainly reported the lack of training and the low number of HIV patients as a barrier to their further involvement in the management of HIV patients. The responding FPs provide care to very few HIV patients. They are, however, willing to be more involved in the routine care of these patients. Medical training provided by COREVIH would help improve HIV screening. The management of HIV patients could thus be handed over to willing FPs. Copyright © 2015. Published by Elsevier SAS.
NASA Astrophysics Data System (ADS)
Kyrkou, Christos; Theocharides, Theocharis
2016-07-01
Object detection is a major step in several computer vision applications and a requirement for most smart camera systems. Recent advances in hardware acceleration for real-time object detection feature extensive use of reconfigurable hardware [field programmable gate arrays (FPGAs)], and relevant research has produced quite fascinating results, in both the accuracy of the detection algorithms as well as the performance in terms of frames per second (fps) for use in embedded smart camera systems. Detecting objects in images, however, is a daunting task and often involves hardware-inefficient steps, both in terms of the datapath design and in terms of input/output and memory access patterns. We present how a visual-feature-directed search cascade composed of motion detection, depth computation, and edge detection, can have a significant impact in reducing the data that needs to be examined by the classification engine for the presence of an object of interest. Experimental results on a Spartan 6 FPGA platform for face detection indicate data search reduction of up to 95%, which results in the system being able to process up to 50 1024×768 pixels images per second with a significantly reduced number of false positives.
NASA Astrophysics Data System (ADS)
Miranda, Michael; White, Andrew; Jalali, Maryam; Sheng, Jian
2017-11-01
A microfluidic bioassay incorporating a peristaltic pump and chemostat capable of continuously culturing a bacterial suspension through a microchannel for an extended period of time relevant to ecological processes is presented. A single crude oil droplet is dispensed on-chip and subsequently pinned to the top and bottom surfaces of the microchannel to establish a vertical curved oil-water interface to observe bacteria without boundary interference. The accumulation of extracellular polymeric substances (EPS), microbial film formation, and aggregation is provided by DIC microscopy with an EMCCD camera at an interval of 30 sec. Cell-interface interactions such as cell translational and angular motilities as well as encountering, attachment, detachment to the interface are obtained by a high speed camera at 1000 fps with a sampling interval of 10 min. Experiments on Pseudomonas sp. (P62) and isolated EPS suspensions from Sagitulla Stelleta and Roseobacter show rapid formation of bacterial aggregates including EPS streamers stretching tens of drop diameters long. These results provide crucial insights into environmentally relevant processes such as the initiation of marine oil snow, an alternative mode of biodegradation to conventional bioconsumption. Funded by GoMRI, NSF, ARO.
Study on Fins' Effect of Boiling Flow in Millimeter Channel Heat Exchanger
NASA Astrophysics Data System (ADS)
Watanabe, Satoshi
2005-11-01
Recently, a lot of researches about compact heat exchangers with mini-channels have been carried out with the hope of obtaining a high-efficiency heat transfer, due to the higher ratio of surface area than existing heat exchangers. However, there are many uncertain phenomena in fields such as boiling flow in mini-channels. Thus, in order to understand the boiling flow in mini-channels to design high-efficiency heat exchangers, this work focused on the visualization measurement of boiling flow in a millimeter channel. A transparent acrylic channel (heat exchanger form), high-speed camera (2000 fps at 1024 x 1024 pixels), and halogen lamp (backup light) were used as the visualization system. The channel's depth is 2 mm, width is 30 mm, and length is 400 mm. In preparation for commercial use, two types of channels were experimented on: a fins type and a normal slit type (without fins). The fins are circular cylindrical obstacles (diameter is 5 mm) to promote heat transfer, set in a triangular array (distance between each center point is 10 mm). Especially in this work, boiling flow and heat transfer promotion in the millimeter channel heat exchanger with fins was evaluated using a high-speed camera.
NASA Technical Reports Server (NTRS)
Barker, Ed; Maley, Paul; Mulrooney, Mark; Beaulieu, Kevin
2009-01-01
In September 2008, a joint ESA/NASA multi-instrument airborne observing campaign was conducted over the Southern Pacific ocean. The objective was the acquisition of data to support detailed atmospheric re-entry analysis for the first flight of the European Automated Transfer Vehicle (ATV)-1. Skilled observers were deployed aboard two aircraft which were flown at 12.8 km altitude within visible range of the ATV-1 re-entry zone. The observers operated a suite of instruments with low-light-level detection sensitivity including still cameras, high speed and 30 fps video cameras, and spectrographs. The collected data has provided valuable information regarding the dynamic time evolution of the ATV-1 re-entry fragmentation. Specifically, the data has satisfied the primary mission objective of recording the explosion of ATV-1's primary fuel tank and thereby validating predictions regarding the tanks demise and the altitude of its occurrence. Furthermore, the data contains the brightness and trajectories of several hundred ATV-1 fragments. It is the analysis of these properties, as recorded by the particular instrument set sponsored by NASA/Johnson Space Center, which we present here.
NASA Astrophysics Data System (ADS)
Roman, D. C.; Neuberg, J.; Luckett, R. R.; White, R. A.
2005-12-01
Systematic changes in the orientation of double-couple fault-plane solutions (FPS) for volcanotectonic (VT) earthquakes have been linked to stress changes induced by the dilation of the magmatic conduit system and may precede the onset of eruption by weeks to months, potentially providing advance warning of an impending eruption. To determine whether analysis of FPS for VT earthquakes recorded during the ongoing eruption of the Soufriere Hills Volcano, Montserrat, could be used to detect the arrival of magma in the mid-level conduit system, we produced a large catalog of high-quality FPS that spanned several phases of the eruption, and then analyzed this catalog to determine whether a temporal correlation exists between eruptive activity and FPS orientation. We repicked VT earthquakes recorded on the Montserrat Volcano Observatory analog and digital seismic networks from the beginning of the eruption in 1995 to May 2005 and relocated them using a 1D velocity model. We then determined well-constrained FPS for the relocated earthquakes. Well-contrained FPS for 607 VT earthquakes indicate primarily oblique strike-slip faulting. In August 1995 (prior to the onset of lava extrusion in September 1995), October 1996-June 1997 (during a period of dome-building), May-November 1999 (prior to the restart of the eruption in November 1999 following a year-long pause), and April-May 2005 (prior to the restart of the eruption in June-August 2005 following a two year pause), FPS pressure (p-) axes are oriented approximately perpendicular to the inferred direction of regional maximum compressive stress around Montserrat. In contrast, FPS p-axes for earthquakes accompanying a pause in the eruption in 1998-1999, and from December 1999-March 2005 are oriented approximately parallel to regional maximum compression. VT earthquakes with FPS p-axes oriented perpendicular to regional maximum compression are thought to reflect local stresses induced by the inflation of a dike-like magmatic conduit system beneath Soufriere Hills prior to and during episodes of eruption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, Kenji; Yoshida, Hiroyuki; Naeppi, Janne
2006-10-15
One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such ''obvious'' FPs due to RTs consistently. In addition, RT-induced FPs maymore » distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding ''teaching'' volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture features. Application of this CAD scheme yielded 96.4% (27/28) by-polyp sensitivity with 3.1 (224/73) FPs per patient, among which 20 FPs were caused by RTs. To eliminate the FPs due to RTs and possibly other normal structures, we trained a 3D MTANN with ten representative polyps and ten RTs, and applied the trained 3D MTANN to the above CAD true- and false-positive detections. In the output volumes of the 3D MTANN, polyps were represented by distributions of bright voxels, whereas RTs and other normal structures partly similar to RTs appeared as darker voxels, indicating the ability of the 3D MTANN to suppress RTs as well as other normal structures effectively. Application of the 3D MTANN to the CAD detections showed that the 3D MTANN eliminated all RT-induced 20 FPs, as well as 53 FPs due to other causes, without removal of any true positives. Overall, the 3D MTANN was able to reduce the FP rate of the CAD scheme from 3.1 to 2.1 FPs per patient (33% reduction), while the original by-polyp sensitivity of 96.4% was maintained.« less
Jabbour, Noel; Sidman, James
2011-10-01
There has been an increasing interest in assessment of technical skills in most medical and surgical disciplines. Many of these assessments involve microscopy or endoscopy and are thus amenable to video recording for post hoc review. An ideal skills assessment video would provide the reviewer with a simultaneous view of the examinee's instrument handling and the operative field. Ideally, a reviewer should be blinded to the identity of the examinee and whether the assessment was performed as a pretest or posttest examination, when given in conjunction with an educational intervention. We describe a simple method for reliably creating deidentified, multicamera, time-synced videos, which may be used in technical skills assessments. We pilot tested this method in a pediatric airway endoscopy Objective Assessment of Technical Skills (OSATS). Total video length was compared with the OSATS administration time. Thirty-nine OSATS were administered. There were no errors encountered in time-syncing the videos using this method. Mean duration of OSATS videos was 11 minutes and 20 seconds, which was significantly less than the time needed for an expert to be present at the administration of each 30-minute OSATS (P < 0.001). The described method for creating time-synced, multicamera skills assessment videos is reliable and may be used in endosurgical or microsurgical skills assessments. Compared with live review, post hoc video review using this method can save valuable expert reviewer time. Most importantly, this method allows a reviewer to simultaneously evaluate an examinee's instrument handling and the operative field while being blinded to the examinee's identity and timing of examination administration.
NASA Astrophysics Data System (ADS)
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-01
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases. This work was partly presented at the 58th Annual meeting of American Association of Physicists in Medicine.
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-21
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases.
Cohen, Ariel; Shappir, Joseph; Yitzchaik, Shlomo; Spira, Micha E
2006-12-15
Understanding the mechanisms that generate field potentials (FPs) by neurons grown on semiconductor chips is essential for implementing neuro-electronic devices. Earlier studies emphasized that FPs are generated by current flow between differentially expressed ion channels on the membranes facing the chip surface, and those facing the culture medium in electrically compact cells. Less is known, however, about the mechanisms that generate FPs by action potentials (APs) that propagate along typical non-isopotential neurons. Using Aplysia neurons cultured on floating gate-transistors, we found that the FPs generated by APs in cultured neurons are produced by current flow along neuronal compartments comprising the axon, cell body, and neurites, rather than by flow between the membrane facing the chip substrate and that facing the culture medium. We demonstrate that the FPs waveform generated by non-isopotential neurons largely depends on the morphology of the neuron.
A far-red fluorescent protein evolved from a cyanobacterial phycobiliprotein
Rodriguez, Erik A.; Tran, Geraldine N.; Gross, Larry A.; Crisp, Jessica L.; Shu, Xiaokun; Lin, John Y.; Tsien, Roger Y.
2016-01-01
Far-red fluorescent proteins (FPs) are desirable for in vivo imaging because less light is scattered, absorbed, or reemitted by endogenous biomolecules. A new class of FP was developed from an allophycocyanin α-subunit (APCα). Native APC requires a lyase to incorporate phycocyanobilin. The evolved FP, named small Ultra-Red FP (smURFP), covalently attaches biliverdin (BV) without a lyase, and has 642/670 nm excitation/emission peaks, a large extinction coefficient (180,000 M−1cm−1) and quantum yield (18%), and comparable photostability to eGFP. SmURFP has significantly increased BV incorporation rate and protein stability compared to the bacteriophytochrome (BPH) FPs. BV supply is limited by membrane permeability, so expression of heme oxygenase-1 with heme precursors increases fluorescence of BPH/APCα FPs. SmURFP (but not BPH FPs) can incorporate a more membrane-permeant BV analog, making smURFP fluorescence in situ comparable to FPs from jellyfish/coral. A far-red/near-infrared fluorescent cell cycle indicator was created with smURFP and a BPH FP. PMID:27479328
NASA Astrophysics Data System (ADS)
Sumriddetchkajorn, Sarun; Chaitavon, Kosom
2009-07-01
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1 ms processing time in highlighting all human face areas. With a thermal imaging camera having an FOV lens of 24° × 18° and 320 × 240 active pixels, the maximum facial skin temperatures from three people's faces located at 1.3 m from the camera can also be simultaneously monitored and displayed in a measured rate of 31 fps, limited by the looping process in determining coordinates of all faces. For our 3-day test under the ambient temperature of 24-30 °C, 57-72% relative humidity, and weak wind from the outside hospital building, hyperthermic patients can be identified with 100% sensitivity and 36.4% specificity when the temperature threshold level and the offset temperature value are appropriately chosen. Appropriately locating our system away from the building doors, air conditioners and electric fans in order to eliminate wind blow coming toward the camera lens can significantly help improve our system specificity.
NASA Astrophysics Data System (ADS)
Malin, Michal C.; Ravine, Michael A.; Caplinger, Michael A.; Tony Ghaemi, F.; Schaffner, Jacob A.; Maki, Justin N.; Bell, James F.; Cameron, James F.; Dietrich, William E.; Edgett, Kenneth S.; Edwards, Laurence J.; Garvin, James B.; Hallet, Bernard; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sletten, Ron; Sullivan, Robert J.; Sumner, Dawn Y.; Aileen Yingst, R.; Duston, Brian M.; McNair, Sean; Jensen, Elsa H.
2017-08-01
The Mars Science Laboratory Mast camera and Descent Imager investigations were designed, built, and operated by Malin Space Science Systems of San Diego, CA. They share common electronics and focal plane designs but have different optics. There are two Mastcams of dissimilar focal length. The Mastcam-34 has an f/8, 34 mm focal length lens, and the M-100 an f/10, 100 mm focal length lens. The M-34 field of view is about 20° × 15° with an instantaneous field of view (IFOV) of 218 μrad; the M-100 field of view (FOV) is 6.8° × 5.1° with an IFOV of 74 μrad. The M-34 can focus from 0.5 m to infinity, and the M-100 from 1.6 m to infinity. All three cameras can acquire color images through a Bayer color filter array, and the Mastcams can also acquire images through seven science filters. Images are ≤1600 pixels wide by 1200 pixels tall. The Mastcams, mounted on the 2 m tall Remote Sensing Mast, have a 360° azimuth and 180° elevation field of regard. Mars Descent Imager is fixed-mounted to the bottom left front side of the rover at 66 cm above the surface. Its fixed focus lens is in focus from 2 m to infinity, but out of focus at 66 cm. The f/3 lens has a FOV of 70° by 52° across and along the direction of motion, with an IFOV of 0.76 mrad. All cameras can acquire video at 4 frames/second for full frames or 720p HD at 6 fps. Images can be processed using lossy Joint Photographic Experts Group and predictive lossless compression.
NASA Astrophysics Data System (ADS)
Sahiner, Berkman; Petrick, Nicholas; Chan, Heang-Ping; Paquerault, Sophie; Helvie, Mark A.; Hadjiiski, Lubomir M.
2001-07-01
We used the correspondence of detected structures on two views of the same breast for false-positive (FP) reduction in computerized detection of mammographic masses. For each initially detected object on one view, we considered all possible pairings with objects on the other view that fell within a radial band defined by the nipple-to-object distances. We designed a 'correspondence classifier' to classify these pairs as either the same mass (a TP-TP pair) or a mismatch (a TP-FP, FP-TP or FP-FP pair). For each pair, similarity measures of morphological and texture features were derived and used as input features in the correspondence classifier. Two-view mammograms from 94 cases were used as a preliminary data set. Initial detection provided 6.3 FPs/image at 96% sensitivity. Further FP reduction in single view resulted in 1.9 FPs/image at 80% sensitivity and 1.1 FPs/image at 70% sensitivity. By combining single-view detection with the correspondence classifier, detection accuracy improved to 1.5 FPs/image at 80% sensitivity and 0.7 FPs/image at 70% sensitivity. Our preliminary results indicate that the correspondence of geometric, morphological, and textural features of a mass on two different views provides valuable additional information for reducing FPs.
Kosteniuk, Julie G; Morgan, Debra G; D'Arcy, Carl K
2013-01-01
The research determined (1) the information sources that family physicians (FPs) most commonly use to update their general medical knowledge and to make specific clinical decisions, and (2) the information sources FPs found to be most physically accessible, intellectually accessible (easy to understand), reliable (trustworthy), and relevant to their needs. A cross-sectional postal survey of 792 FPs and locum tenens, in full-time or part-time medical practice, currently practicing or on leave of absence in the Canadian province of Saskatchewan was conducted during the period of January to April 2008. Of 666 eligible physicians, 331 completed and returned surveys, resulting in a response rate of 49.7% (331/666). Medical textbooks and colleagues in the main patient care setting were the top 2 sources for the purpose of making specific clinical decisions. Medical textbooks were most frequently considered by FPs to be reliable (trustworthy), and colleagues in the main patient care setting were most physically accessible (easy to access). When making specific clinical decisions, FPs were most likely to use information from sources that they considered to be reliable and generally physically accessible, suggesting that FPs can best be supported by facilitating easy and convenient access to high-quality information.
Testing neurophysiological markers related to fear-potentiated startle.
Seligowski, Antonia V; Bondy, Erin; Singleton, Paris; Orcutt, Holly K; Ressler, Kerry J; Auerbach, Randy P
2018-06-11
Fear-potentiated startle (FPS) paradigms provide insight into fear learning mechanisms that contribute to impairment among individuals with posttraumatic stress symptoms (PTSS). Electrophysiology also has provided insight into these mechanisms through the examination of event-related potentials (ERPs) such as the P100 and LPP. It remains unclear, however, whether the P100 and LPP may be related to fear learning processes within the FPS paradigm. To this end, we tested differences in ERP amplitudes for conditioned stimuli associated (CS+) and not associated (CS-) with an aversive unconditioned stimulus (US) during fear acquisition. Participants included 54 female undergraduate students (mean age = 20.26). The FPS response was measured via electromyography of the orbicularis oculi muscle. EEG data were collected during the FPS paradigm. While the difference between CS+ and CS- P100 amplitude was not significant, LPP amplitudes were significantly enhanced following the CS+ relative to CS-. Furthermore, the LPP difference wave (CS+ minus CS-) was associated with FPS scores for the CS- during the later portion of fear acquisition. These findings suggest that conditioned stimuli may have altered emotional encoding (LPP) during the FPS paradigm. Thus, the LPP may be a promising neurophysiological marker that is related to fear learning processes. Copyright © 2018 Elsevier B.V. All rights reserved.
Povarova, Natalia V.; Petri, Natalia D.; Blokhina, Anna E.; Bogdanov, Alexey M.; Lukyanov, Konstantin A.
2017-01-01
Despite great advances in practical applications of fluorescent proteins (FPs), their natural function is poorly understood. FPs display complex spatio-temporal expression patterns in living Anthozoa coral polyps. Here we applied confocal microscopy, specifically, the fluorescence recovery after photobleaching (FRAP) technique to analyze intracellular localization and mobility of endogenous FPs in live tissues. We observed three distinct types of protein distributions in living tissues. One type of distribution, characteristic for Anemonia, Discosoma and Zoanthus, is free, highly mobile cytoplasmic localization. Another pattern is seen in FPs localized to numerous intracellular vesicles, observed in Clavularia. The third most intriguing type of intracellular localization is with respect to the spindle-shaped aggregates and lozenge crystals several micrometers in size observed in Zoanthus samples. No protein mobility within those structures was detected by FRAP. This finding encouraged us to develop artificial aggregating FPs. We constructed “trio-FPs” consisting of three tandem copies of tetrameric FPs and demonstrated that they form multiple bright foci upon expression in mammalian cells. High brightness of the aggregates is advantageous for early detection of weak promoter activities. Simultaneously, larger aggregates can induce significant cytostatic and cytotoxic effects and thus such tags are not suitable for long-term and high-level expression. PMID:28704934
Kosteniuk, Julie G.; Morgan, Debra G.; D'Arcy, Carl K.
2013-01-01
Objectives: The research determined (1) the information sources that family physicians (FPs) most commonly use to update their general medical knowledge and to make specific clinical decisions, and (2) the information sources FPs found to be most physically accessible, intellectually accessible (easy to understand), reliable (trustworthy), and relevant to their needs. Methods: A cross-sectional postal survey of 792 FPs and locum tenens, in full-time or part-time medical practice, currently practicing or on leave of absence in the Canadian province of Saskatchewan was conducted during the period of January to April 2008. Results: Of 666 eligible physicians, 331 completed and returned surveys, resulting in a response rate of 49.7% (331/666). Medical textbooks and colleagues in the main patient care setting were the top 2 sources for the purpose of making specific clinical decisions. Medical textbooks were most frequently considered by FPs to be reliable (trustworthy), and colleagues in the main patient care setting were most physically accessible (easy to access). Conclusions: When making specific clinical decisions, FPs were most likely to use information from sources that they considered to be reliable and generally physically accessible, suggesting that FPs can best be supported by facilitating easy and convenient access to high-quality information. PMID:23405045
The past, present and future of fluorescent protein tags in anaerobic protozoan parasites.
Morin-Adeline, Victoria; Šlapeta, Jan
2016-03-01
The world health organization currently recognizes diarrhoeal diseases as a significant cause of death in children globally. Protozoan parasites such as Giardia and Entamoeba that thrive in the oxygen-deprived environment of the human gut are common etiological agents of diarrhoea. In the urogenital tract of humans, the anaerobic protozoan parasite Trichomonas vaginalis is notorious as the most common non-viral, sexually transmitted pathogen. Even with high medical impact, our understanding of anaerobic parasite physiology is scarce and as a result, treatment choices are limited. Fluorescent proteins (FPs) are invaluable tools as genetically encoded protein tags for advancing knowledge of cellular function. These FP tags emit fluorescent colours and once attached to a protein of interest, allow tracking of parasite proteins in the dynamic cellular space. Application of green FPs-like FPs in anaerobic protozoans is hindered by their oxygen dependency. In this review, we examine aspects of anaerobic parasite biology that clash with physio-chemical properties of FPs and limit their use as live-parasite protein tags. We expose novel FPs, such as miniSOG that do not require oxygen for signal production. The potential use of novel FPs has the opportunity to leverage the anaerobe parasitologist toolkit to that of aerobe parasitologist.
Shen, Chao; Ma, Yingjuan; Zeng, Ziling; Yin, Qingqing; Hong, Yan; Hou, Xunyao; Liu, Xueping
2017-10-01
Advanced glycation end products (AGEs) enhance microglial activation and intensify the inflammatory response and oxidative stress in the brain. This process may occur due to direct cytotoxicity or interacting with AGEs receptors (RAGE), which are expressed on the surface of microglia. FPS-ZM1 is a high-affinity but nontoxic RAGE-specific inhibitor that has been recently shown to attenuate the Aβ-induced inflammatory response by blocking the ligation of Aβ to RAGE. In this study, we further investigated the effect of FPS-ZM1 on the AGEs/RAGE interaction and downstream elevation of neuroinflammation and oxidative stress in primary microglia cells. The results suggested that FPS-ZM1 significantly suppressed AGEs-induced RAGE overexpression, RAGE-dependent microglial activation, nuclear translocation of nuclear factor kappaB p65 (NF-κB p65), and the expression of downstream inflammatory mediators such as tumor necrosis factor-alpha (TNF-α), interleukin-1 beta (IL-1β), cyclooxygenase 2 (COX-2)/prostaglandin E2 (PGE2) and inducible nitric oxide synthase (iNOS)/nitric oxide (NO). Furthermore, FPS-ZM1 attenuated AGEs-stimulated NADPH oxidase (NOX) activation and reactive oxygen species (ROS) expression. Finally, FPS-ZM1 elevated the levels of transcription factors nuclear-factor (erythroid-derived 2)-like 2 (Nrf2) and heme oxygenase-1 (HO-1), as well as decreased antioxidant capacity and increased production of oxidative species. Our results suggest that FPS-ZM1 may be neuroprotective through attenuating microglial activation, oxidative stress and inflammation by blocking RAGE.
Detecting TLEs using a massive all-sky camera network
NASA Astrophysics Data System (ADS)
Garnung, M. B.; Celestin, S. J.
2017-12-01
Transient Luminous Events (TLEs) are large-scale optical events occurring in the upper-atmosphere from the top of thunderclouds up to the ionosphere. TLEs may have important effects in local, regional, and global scales, and many features of TLEs are not fully understood yet [e.g, Pasko, JGR, 115, A00E35, 2010]. Moreover, meteor events have been suggested to play a role in sprite initiation by producing ionospheric irregularities [e.g, Qin et al., Nat. Commun., 5, 3740, 2014]. The French Fireball Recovery and InterPlanetary Observation Network (FRIPON, https://www.fripon.org/?lang=en), is a national all-sky 30 fps camera network designed to continuously detect meteor events. We seek to make use of this network to observe TLEs over unprecedented space and time scales ( 1000×1000 km with continuous acquisition). To do so, we had to significantly modify FRIPON's triggering software Freeture (https://github.com/fripon/freeture) while leaving the meteor detection capability uncompromised. FRIPON has a great potential in the study of TLEs. Not only could it produce new results about spatial and time distributions of TLEs over a very large area, it could also be used to validate and complement observations from future space missions such as ASIM (ESA) and TARANIS (CNES). In this work, we present an original image processing algorithm that can detect sprites using all-sky cameras while strongly limiting the frequency of false positives and our ongoing work on sprite triangulation using the FRIPON network.
Yoshida, Eriko; Terada, Shin-Ichiro; Tanaka, Yasuyo H; Kobayashi, Kenta; Ohkura, Masamichi; Nakai, Junichi; Matsuzaki, Masanori
2018-05-29
In vivo wide-field imaging of neural activity with a high spatio-temporal resolution is a challenge in modern neuroscience. Although two-photon imaging is very powerful, high-speed imaging of the activity of individual synapses is mostly limited to a field of approximately 200 µm on a side. Wide-field one-photon epifluorescence imaging can reveal neuronal activity over a field of ≥1 mm 2 at a high speed, but is not able to resolve a single synapse. Here, to achieve a high spatio-temporal resolution, we combine an 8 K ultra-high-definition camera with spinning-disk one-photon confocal microscopy. This combination allowed us to image a 1 mm 2 field with a pixel resolution of 0.21 µm at 60 fps. When we imaged motor cortical layer 1 in a behaving head-restrained mouse, calcium transients were detected in presynaptic boutons of thalamocortical axons sparsely labeled with GCaMP6s, although their density was lower than when two-photon imaging was used. The effects of out-of-focus fluorescence changes on calcium transients in individual boutons appeared minimal. Axonal boutons with highly correlated activity were detected over the 1 mm 2 field, and were probably distributed on multiple axonal arbors originating from the same thalamic neuron. This new microscopy with an 8 K ultra-high-definition camera should serve to clarify the activity and plasticity of widely distributed cortical synapses.
Fischer, Thomas; Fischer, Susanne; Himmel, Wolfgang; Kochen, Michael M; Hummers-Pradier, Eva
2008-01-01
The influence of patient characteristics on family practitioners' (FPs') diagnostic decision making has mainly been investigated using indirect methods such as vignettes or questionnaires. Direct observation-borrowed from social and cultural anthropology-may be an alternative method for describing FPs' real-life behavior and may help in gaining insight into how FPs diagnose respiratory tract infections, which are frequent in primary care. To clarify FPs' diagnostic processes when treating patients suffering from symptoms of respiratory tract infection. This direct observation study was performed in 30 family practices using a checklist for patient complaints, history taking, physical examination, and diagnoses. The influence of patients' symptoms and complaints on the FPs' physical examination and diagnosis was calculated by logistic regression analyses. Dummy variables based on combinations of symptoms and complaints were constructed and tested against saturated (full) and backward regression models. In total, 273 patients (median age 37 years, 51% women) were included. The median number of symptoms described was 4 per patient, and most information was provided at the patients' own initiative. Multiple logistic regression analysis showed a strong association between patients' complaints and the physical examination. Frequent diagnoses were upper respiratory tract infection (URTI)/common cold (43%), bronchitis (26%), sinusitis (12%), and tonsillitis (11%). There were no significant statistical differences between "simple heuristic'' models and saturated regression models in the diagnoses of bronchitis, sinusitis, and tonsillitis, indicating that simple heuristics are probably used by the FPs, whereas "URTI/common cold'' was better explained by the full model. FPs tended to make their diagnosis based on a few patient symptoms and a limited physical examination. Simple heuristic models were almost as powerful in explaining most diagnoses as saturated models. Direct observation allowed for the study of decision making under real conditions, yielding both quantitative data and "qualitative'' information about the FPs' performance. It is important for investigators to be aware of the specific disadvantages of the method (e.g., a possible observer effect).
Pool boiling of ethanol and FC-72 on open microchannel surfaces
NASA Astrophysics Data System (ADS)
Kaniowski, Robert; Pastuszko, Robert
2018-06-01
The paper presents experimental investigations into pool boiling heat transfer for open microchannel surfaces. Parallel microchannels fabricated by machining were about 0.3 mm wide, and 0.2 to 0.5 mm deep and spaced every 0.1 mm. The experiments were carried out for ethanol, and FC-72 at atmospheric pressure. The image acquisition speed was 493 fps (at resolution 400 × 300 pixels with Photonfocus PHOT MV-D1024-160-CL camera). Visualization investigations aimed to identify nucleation sites and flow patterns and to determine the bubble departure diameter and frequency at various superheats. The primary factor in the increase of heat transfer coefficient at increasing heat flux was a growing number of active pores and increased departure frequency. Heat transfer coefficients obtained in this study were noticeably higher than those from a smooth surface.
Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC)
2017-01-01
We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification—an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC), is a single-shot variant of Differential Phase Contrast (DPC), which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps) for various in vitro cell samples and c. elegans in a micro-fluidic channel. PMID:28152023
Kraus, Wayne A; Wagner, Albert F
1986-04-01
A triatomic classical trajectory code has been modified by extensive vectorization of the algorithms to achieve much improved performance on an FPS 164 attached processor. Extensive timings on both the FPS 164 and a VAX 11/780 with floating point accelerator are presented as a function of the number of trajectories simultaneously run. The timing tests involve a potential energy surface of the LEPS variety and trajectories with 1000 time steps. The results indicate that vectorization results in timing improvements on both the VAX and the FPS. For larger numbers of trajectories run simultaneously, up to a factor of 25 improvement in speed occurs between VAX and FPS vectorized code. Copyright © 1986 John Wiley & Sons, Inc.
Dangat, Celina M; Njau, Bernard
2013-01-01
Almost 65% of the Tanzanian population is under the age of 24 and almost 20 % of the population is aged 15-24 years. Yet, this important group faces many significant health challenges, such as early sexual debut, early pregnancies, risky behaviours and sexually transmitted infections. The objective of this study was to assess knowledge, attitudes and practices on family planning services among adolescents in secondary schools in Hai District in northern Tanzania. A cross sectional study was conducted between April and June 2011 among 316 randomly selected students in 10 secondary schools using a self administered pre-tested questionnaire. Median age of participants was 17 years (15-19 years). Two-thirds (67.4%) of the respondents had adequate level of knowledge on family planning services (FPS) and the most popular source of information was the radio (65.8 %). Being in a lower class (χ2 =8.6; P<0.02) and attending co education schools (χ2 =12.9; P< 0.001) were predictors of inadequate level of knowledge on FPS. Most, 71.2% (225/316) respondents reported that FPS should not be used by adolescents and mentioned several reasons against its use. Less than 6 % (18/316) of all respondents had used FPS in their lifetime, with 44.4 % (8/18) in the past month, 33.3 %(6/18) in the past year, and 22.3 % (4/18) in the past 5 years. In conclusion, most secondary school students in Hai District do not utilize family planning services despite of adequate level of knowledge on FPS. Interventions to improve utilization of FPS among secondary school students should address barriers to low utilization of FPS mentioned in this study.
Godoy, R F; Coathup, M J; Blunn, G W; Alves, A L; Robotti, P; Goodship, A E
2016-04-13
We explored the osseointegration potential of two macroporous titanium surfaces obtained using fast plasma sintering (FPS): Ti macroporous structures with 400-600 µmØ pores (TiMac400) and 850-1000 µmØ pores (TiMac850). They were compared against two surfaces currently in clinical use: Ti-Growth® and air plasma spray (Ti-Y367). Each surface was tested, once placed over a Ti-alloy and once onto a CoCr bulk substrate. Implants were placed in medial femoral condyles in 24 sheep. Samples were explanted at four and eight weeks after surgery. Push-out loads were measured using a material-testing system. Bone contact and ingrowth were assessed by histomorphometry and SEM and EDX analyses. Histology showed early osseointegration for all the surfaces tested. At 8 weeks, TiMac400, TiMac850 and Ti-Growth® showed deep bone ingrowth and extended colonisation with newly formed bone. The mechanical push-out force was equal in all tested surfaces. Plasma spray surfaces showed greater bone-implant contact and higher level of pores colonisation with new bone than FPS produced surfaces. However, the void pore area in FPS specimens was significantly higher, yet the FPS porous surfaces allowed a deeper osseointegration of bone to implant. FPS manufactured specimens showed similar osseointegration potential to the plasma spray surfaces for orthopaedic implants. FPS is a useful technology for manufacturing macroporous titanium surfaces. Furthermore, its capability to combine two implantable materials, using bulk CoCr with macroporous titanium surfaces, could be of interest as it enables designers to conceive and manufacture innovative components. FPS delivers functional graded materials components with macroporous structures optimised for osseointegration.
Ballistics of the 30-06 Rifle Cartridge
2012-11-30
manuals for common bullet weights. Hodgdon, Nosler, and Barnes report velocities for 24" barrels . Hornady and Speer report velocoties for 22" barrels ...The data are all for barrels with a twist rate of 1 turn in 10” which is needed to stabilize the heaviest bullets. The higher muzzle velocities...are available that provide 2900 fps for 150 grain bullets, 2800 fps for 165 grain bullets, and 2700 fps for 180 grain bullets (in a 24 inch barrel
Kim, Yong-Kyoung; Kim, Yeon Bok; Uddin, Md Romij; Lee, Sanghyun; Kim, Soo-Un; Park, Sang Un
2014-10-17
To elucidate the function of mevalonate-5-pyrophosphate decarboxylase (MVD) and farnesyl pyrophosphate synthase (FPS) in triterpene biosynthesis, the genes governing the expression of these enzymes were transformed into Panax ginseng hairy roots. All the transgenic lines showed higher expression levels of PgMVD and PgFPS than that by the wild-type control. Among the hairy root lines transformed with PgMVD, M18 showed the highest level of transcription compared to the control (14.5-fold higher). Transcriptions of F11 and F20 transformed with PgFPS showed 11.1-fold higher level compared with control. In triterpene analysis, M25 of PgMVD produced 4.4-fold higher stigmasterol content (138.95 μg/100 mg, dry weight [DW]) than that by the control; F17 of PgFPS showed the highest total ginsenoside (36.42 mg/g DW) content, which was 2.4-fold higher compared with control. Our results indicate that metabolic engineering in P. ginseng was successfully achieved through Agrobacterium rhizogenes-mediated transformation and that the accumulation of phytosterols and ginsenosides was enhanced by introducing the PgMVD and PgFPS genes into the hairy roots of the plant. Our results suggest that PgMVD and PgFPS play an important role in the triterpene biosynthesis of P. ginseng.
Participation and successful patient recruitment in primary care.
de Wit, N J; Quartero, A O; Zuithoff, A P; Numans, M E
2001-11-01
The demand for family physicians (FPs) to participate in research is growing. The delicate balance between research participation and the daily practice routine might explain the often-disappointing number of patients recruited. We analyzed practice and physician characteristics associated with successful patient recruitment. We used a survey to conduct this study. There was a total of 165 FPs who participated in a combined randomized clinical trial/cohort study on drug treatment of dyspepsia in the Netherlands. We surveyed FPs about personal and practice characteristics and their motivation for participation in the project. These data were then related to the number of patients recruited. Univariate associations were calculated; relevant factors were entered into a logistic model that predicted patient recruitment. Data on 128 FPs could be analyzed (80% response rate); these FPs recruited 793 patients in the cohort study (mean = 6.3 per FP) and 527 in the clinical trial (mean = 4.2 per FP). The main reasons for participation were the research topic (59%) and the participation of an academic research group in the study (63%). Many FPs felt that participation was a professional obligation (39%); the financial incentive played a minor role (15%). The number of recruited patients was only independently associated with the participation of an academic research group. Successful patient recruitment in primary care research is determined more by motivation driven by the research group than by financial incentives, the research topic, or research experience.
Kofoed, Eric M.; Guerbadot, Martin; Schaufele, Fred
2008-01-01
Förster resonance energy transfer (FRET) detection of protein interaction in living cells is commonly measured following the expression of interacting proteins genetically fused to the cyan (CFP) and yellow (YFP) derivatives of the Aequorea victoria fluorescent protein (FP). These FPs can dimerize at mM concentrations, which may introduce artifacts into the measurement of interaction between proteins that are fused with the FPs. Here, FRET analysis of the interaction between estrogen receptors (alpha isoform, ERα) labeled with “wild-type” CFP and YFP is compared with that of ERα labeled with “monomeric” A206K mutants of CFP and YFP. The intracellular equilibrium dissociation constant for the hormone-induced ERα-ERα interaction is similar for ERα labeled with wild-type or monomeric FPs. However, the measurement of energy transfer measured for ERα-ERα interaction in each cell is less consistent with the monomeric FPs. Thus, dimerization of the FPs does not affect the kinetics of ERα-ERα interaction but, when brought close together via ERα-ERα interaction, FP dimerization modestly improves FRET measurement. PMID:18601531
A far-red fluorescent protein evolved from a cyanobacterial phycobiliprotein.
Rodriguez, Erik A; Tran, Geraldine N; Gross, Larry A; Crisp, Jessica L; Shu, Xiaokun; Lin, John Y; Tsien, Roger Y
2016-09-01
Far-red fluorescent proteins (FPs) are desirable for in vivo imaging because with these molecules less light is scattered, absorbed, or re-emitted by endogenous biomolecules compared with cyan, green, yellow, and orange FPs. We developed a new class of FP from an allophycocyanin α-subunit (APCα). Native APC requires a lyase to incorporate phycocyanobilin. The evolved FP, which we named small ultra-red FP (smURFP), covalently attaches a biliverdin (BV) chromophore without a lyase, and has 642/670-nm excitation-emission peaks, a large extinction coefficient (180,000 M(-1)cm(-1)) and quantum yield (18%), and photostability comparable to that of eGFP. smURFP has significantly greater BV incorporation rate and protein stability than the bacteriophytochrome (BPH) FPs. Moreover, BV supply is limited by membrane permeability, and smURFPs (but not BPH FPs) can incorporate a more membrane-permeant BV analog, making smURFP fluorescence comparable to that of FPs from jellyfish or coral. A far-red and near-infrared fluorescent cell cycle indicator was created with smURFP and a BPH FP.
FPS-RAM: Fast Prefix Search RAM-Based Hardware for Forwarding Engine
NASA Astrophysics Data System (ADS)
Zaitsu, Kazuya; Yamamoto, Koji; Kuroda, Yasuto; Inoue, Kazunari; Ata, Shingo; Oka, Ikuo
Ternary content addressable memory (TCAM) is becoming very popular for designing high-throughput forwarding engines on routers. However, TCAM has potential problems in terms of hardware and power costs, which limits its ability to deploy large amounts of capacity in IP routers. In this paper, we propose new hardware architecture for fast forwarding engines, called fast prefix search RAM-based hardware (FPS-RAM). We designed FPS-RAM hardware with the intent of maintaining the same search performance and physical user interface as TCAM because our objective is to replace the TCAM in the market. Our RAM-based hardware architecture is completely different from that of TCAM and has dramatically reduced the costs and power consumption to 62% and 52%, respectively. We implemented FPS-RAM on an FPGA to examine its lookup operation.
Elliott, Luther; Golub, Andrew; Price, Matthew; Bennett, Alexander
2015-08-01
This article examines recent combat veterans' experiences of "first-person shooter" (FPS) gaming and its relationship to posttraumatic stress disorder (PTSD). Current PTSD treatment approaches increasingly use virtual reality (VR) technologies, which have many similarities with FPS games. To explore these similarities, this article presents six case studies from recently separated veterans in New York City who reported both current PTSD symptoms and regular use of combat-themed FPS games. In open-ended interviews, participants discussed a range of benefits as well as the importance of regulating use and avoiding particular contextual dimensions of gaming to maintain healthy gaming habits. Findings demonstrate the need for more comprehensive study and dissemination of best-practices information about FPS gaming in the context of combat-related PTSD symptomatology.
Peikon, Ian D; Fitzsimmons, Nathan A; Lebedev, Mikhail A; Nicolelis, Miguel A L
2009-06-15
Collection and analysis of limb kinematic data are essential components of the study of biological motion, including research into biomechanics, kinesiology, neurophysiology and brain-machine interfaces (BMIs). In particular, BMI research requires advanced, real-time systems capable of sampling limb kinematics with minimal contact to the subject's body. To answer this demand, we have developed an automated video tracking system for real-time tracking of multiple body parts in freely behaving primates. The system employs high-contrast markers painted on the animal's joints to continuously track the three-dimensional positions of their limbs during activity. Two-dimensional coordinates captured by each video camera are combined and converted to three-dimensional coordinates using a quadratic fitting algorithm. Real-time operation of the system is accomplished using direct memory access (DMA). The system tracks the markers at a rate of 52 frames per second (fps) in real-time and up to 100fps if video recordings are captured to be later analyzed off-line. The system has been tested in several BMI primate experiments, in which limb position was sampled simultaneously with chronic recordings of the extracellular activity of hundreds of cortical cells. During these recordings, multiple computational models were employed to extract a series of kinematic parameters from neuronal ensemble activity in real-time. The system operated reliably under these experimental conditions and was able to compensate for marker occlusions that occurred during natural movements. We propose that this system could also be extended to applications that include other classes of biological motion.
Chester, Julia A.; Weera, Marcus M.
2016-01-01
Post-traumatic stress disorder (PTSD) and alcohol-use disorders have a high rate of co-occurrence, possibly because they are regulated by common genes. In support of this idea, mice selectively bred for high (HAP) alcohol preference show greater fear potentiated startle (FPS), a model for fear-related disorders such as PTSD, compared to mice selectively bred for low (LAP) alcohol preference. This positive genetic correlation between alcohol preference and FPS behavior suggests that the two traits may be functionally related. This study examined the effects of fear conditioning on alcohol consumption and the effects of alcohol consumption on the expression of FPS in male and female HAP2 and LAP2 mice. In experiment 1, alcohol consumption (g/kg) under continuous-access conditions was monitored daily for 4 weeks following a single fear-conditioning or control treatment (foot shock and no shock). FPS was assessed three times (once at the end of the 4-week alcohol access period, once at 24 h after removal of alcohol, and once at 6–8 days after removal of alcohol), followed by two more weeks of alcohol access. Results showed no change in alcohol consumption, but alcohol-consuming, fear-conditioned, HAP2 males showed increased FPS at 24 h during the alcohol abstinence period compared to control groups. In experiment 2, alcohol consumption under limited-access conditions was monitored daily for 4 weeks. Fear-conditioning or control treatments occurred four times during the first 12 days and FPS testing occurred four times during the second 12 days of the 4-week alcohol consumption period. Results showed that fear conditioning increased alcohol intake in both HAP2 and LAP2 mice immediately following the first conditioning session. Fear-conditioned HAP2 but not LAP2 mice showed greater alcohol intake compared to control groups on drinking days that occurred between fear conditioning and FPS test sessions. FPS did not change as a function of alcohol consumption in either line. These results in mice help shed light on how a genetic propensity toward high alcohol consumption may be related to the risk for developing PTSD and co-morbid alcohol-use disorders in humans. PMID:27908524
Inexpensive driver for stereo videogame glasses
NASA Astrophysics Data System (ADS)
Pique, Michael; Coogan, Anthony
1990-09-01
We have adapted home videogame glasses from Sega as workstation stereo viewers. A small (4x7x9 cm.) box of electronics receives sync signals in parallel with the monitor (either separate ROB-Sync or composite video) and drives the glasses.The view is dimmer than with costlier shutters, there is more ghosting, and the user is feuered by the wires. But the glasses are so much cheaper than the full-screen shutters (250 instead of about 10 000) that it is practical to provide the benefits of stereo to many more workstation users. We are using them with Sun TAAC-1 workstations; the interlaced video can also be recorded on ordinary NTSC videotape and played on television monitors.
More than Just a Game? Combat-Themed Gaming Among Recent Veterans with Posttraumatic Stress Disorder
Golub, Andrew; Price, Matthew; Bennett, Alexander
2015-01-01
Abstract This article examines recent combat veterans' experiences of “first-person shooter” (FPS) gaming and its relationship to posttraumatic stress disorder (PTSD). Current PTSD treatment approaches increasingly use virtual reality (VR) technologies, which have many similarities with FPS games. To explore these similarities, this article presents six case studies from recently separated veterans in New York City who reported both current PTSD symptoms and regular use of combat-themed FPS games. In open-ended interviews, participants discussed a range of benefits as well as the importance of regulating use and avoiding particular contextual dimensions of gaming to maintain healthy gaming habits. Findings demonstrate the need for more comprehensive study and dissemination of best-practices information about FPS gaming in the context of combat-related PTSD symptomatology. PMID:26182214
Energy efficient engine: Flight propulsion system preliminary analysis and design
NASA Technical Reports Server (NTRS)
Johnston, R. P.; Beitler, R. S.; Bobinger, R. O.; Broman, C. L.; Gravitt, R. D.; Heineke, H.; Holloway, P. R.; Klem, J. S.; Nash, D. O.; Ortiz, P.
1980-01-01
The characteristics of an advanced flight propulsion system (FPS), suitable for introduction in the late 1980's to early 1990's, was more fully defined. It was determined that all goals for efficiency, environmental considerations, and economics could be met or exceeded with the possible exception of NOx emission. In evaluating the FPS, all aspects were considered including component design, performance, weight, initial cost, maintenance cost, engine system integration (including nacelle), and aircraft integration considerations. The current FPS installed specific fuel consumption was reduced 14.2% from that of the CF6-50C reference engine. When integrated into an advanced, subsonic, study transport, the FPS produced a fuel burn savings of 15 to 23% and a direct operating cost reduction of 5 to 12% depending on the mission and study aircraft characteristics relative to the reference engine.
A Survey to Assess Family Physicians’ Motivation to Teach Undergraduates in Their Practices
May, Marcus; Mand, Peter; Biertz, Frank; Hummers-Pradier, Eva; Kruschinski, Carsten
2012-01-01
Background In Germany, family physicians (FPs) are increasingly needed to participate in undergraduate medical education. Knowledge of FPs’ motivation to teach medical students in their practices is lacking. Purpose To describe a novel questionnaire that assesses the motivation of FPs to teach undergraduates in their practices and to show the results of a subsequent survey using this instrument. Methods The questionnaire was developed based on a review of the literature. Previously used empirical instruments assessing occupational values and motivation were included. A preliminary version was pretested in a pilot study. The resulting 68-item questionnaire was sent to 691 FPs involved in undergraduate medical education. Reliability was assessed and subgroups were analyzed with regard to differences in motivation. Results A total of 523 physicians in n = 458 teaching practices participated (response rate 75.7%). ‘Helping others’ and ‘interest’ were revealed as the predominant motives. Responses showed a predominantly intrinsic motivation of the participating FPs. Their main incentives were an ambition to work as a medical preceptor, to generally improve undergraduate education and to share knowledge. Material compensation was of minor importance. Time restraints were indicated as a barrier by some FPs, but were not a general concern. Conclusion German FPs involved in medical education have altruistic attitudes towards teaching medical students in their practices. Motivational features give an important insight for the recruitment of FP preceptors as well as for their training in instructional methods. PMID:23029272
Spychała, Marcin; Nieć, Jakub; Pawlak, Maciej
2013-01-01
In this paper, the preliminary study on the impact of filamentous particles (FP) in the septic tank effluent (STE) on filter cake (FC) development was presented. The number, length and diameter (30 p./cm3, 451 and 121 microm, respectively, on average) of FPs were measured using microscope image analysis of STE samples condensed using a vacuum evaporation set. Results of this study showed, that 0.73% of volatile suspended solids (VSSs) mass from the STE occurs in the form of FPs. No correlation between FP total mass and VSS was found. An experiment with a layer of FPs simulated by ground toilet paper was conducted and showed the impact of this layer (4.89 mg/cm2) on wastewater hydraulic conductivity--for an FC with FPs (FC-FP), hydraulic conductivity was seven times lower than for the FC without the FP layer, and on outflow quality (lower concentration of organic matter expressed as chemical oxygen demand (COD) in effluent from the FC-FP filter than in the effluent from the FC filter: 618 and 732 gO2/m3, respectively). Despite a relatively small amount of FPs in STE solids (as volume fraction), they play an important role in FC development due to their relatively high length and low degradability. Probably relatively small pores of the FC containing FPs (FC-FP) caused a small particle blocking and a decrease in permeability.
Deliyski, Dimitar D; Powell, Maria EG; Zacharias, Stephanie RC; Gerlach, Terri Treman; de Alarcon, Alessandro
2015-01-01
This study investigated the impact of high-speed videoendoscopy (HSV) frame rates on the assessment of nine clinically-relevant vocal-fold vibratory features. Fourteen adult patients with voice disorder and 14 adult normal controls were recorded using monochromatic rigid HSV at a rate of 16000 frames per second (fps) and spatial resolution of 639×639 pixels. The 16000-fps data were downsampled to 16 other rate denominations. Using paired comparisons design, nine common clinical vibratory features were visually compared between the downsampled and the original images. Three raters reported the thresholds at which: (1) a detectable difference between the two videos was first noticed, and (2) differences between the two videos would result in a change of clinical rating. Results indicated that glottal edge, mucosal wave magnitude and extent, aperiodicity, contact and loss of contact of the vocal folds were the vibratory features most sensitive to frame rate. Of these vibratory features, the glottal edge was selected for further analysis, due to its higher rating reliability, universal prevalence and consistent definition. Rates of 8000 fps were found to be free from visually-perceivable feature degradation, and for rates of 5333 fps, degradation was minimal. For rates of 4000 fps and higher, clinical assessments of glottal edge were not affected. Rates of 2000 fps changed the clinical ratings in over 16% of the samples, which could lead to inaccurate functional assessment. PMID:28989342
Real-time 3D human capture system for mixed-reality art and entertainment.
Nguyen, Ta Huynh Duy; Qui, Tran Cong Thien; Xu, Ke; Cheok, Adrian David; Teo, Sze Lee; Zhou, ZhiYing; Mallawaarachchi, Asitha; Lee, Shang Ping; Liu, Wei; Teo, Hui Siang; Thang, Le Nam; Li, Yu; Kato, Hirokazu
2005-01-01
A real-time system for capturing humans in 3D and placing them into a mixed reality environment is presented in this paper. The subject is captured by nine cameras surrounding her. Looking through a head-mounted-display with a camera in front pointing at a marker, the user can see the 3D image of this subject overlaid onto a mixed reality scene. The 3D images of the subject viewed from this viewpoint are constructed using a robust and fast shape-from-silhouette algorithm. The paper also presents several techniques to produce good quality and speed up the whole system. The frame rate of our system is around 25 fps using only standard Intel processor-based personal computers. Besides a remote live 3D conferencing and collaborating system, we also describe an application of the system in art and entertainment, named Magic Land, which is a mixed reality environment where captured avatars of human and 3D computer generated virtual animations can form an interactive story and play with each other. This system demonstrates many technologies in human computer interaction: mixed reality, tangible interaction, and 3D communication. The result of the user study not only emphasizes the benefits, but also addresses some issues of these technologies.
NASA Astrophysics Data System (ADS)
Boisson, Guillaume; Kerbiriou, Paul; Drazic, Valter; Bureller, Olivier; Sabater, Neus; Schubert, Arno
2014-03-01
Generating depth maps along with video streams is valuable for Cinema and Television production. Thanks to the improvements of depth acquisition systems, the challenge of fusion between depth sensing and disparity estimation is widely investigated in computer vision. This paper presents a new framework for generating depth maps from a rig made of a professional camera with two satellite cameras and a Kinect device. A new disparity-based calibration method is proposed so that registered Kinect depth samples become perfectly consistent with disparities estimated between rectified views. Also, a new hierarchical fusion approach is proposed for combining on the flow depth sensing and disparity estimation in order to circumvent their respective weaknesses. Depth is determined by minimizing a global energy criterion that takes into account the matching reliability and the consistency with the Kinect input. Thus generated depth maps are relevant both in uniform and textured areas, without holes due to occlusions or structured light shadows. Our GPU implementation reaches 20fps for generating quarter-pel accurate HD720p depth maps along with main view, which is close to real-time performances for video applications. The estimated depth is high quality and suitable for 3D reconstruction or virtual view synthesis.
A method for the real-time construction of a full parallax light field
NASA Astrophysics Data System (ADS)
Tanaka, Kenji; Aoki, Soko
2006-02-01
We designed and implemented a light field acquisition and reproduction system for dynamic objects called LiveDimension, which serves as a 3D live video system for multiple viewers. The acquisition unit consists of circularly arranged NTSC cameras surrounding an object. The display consists of circularly arranged projectors and a rotating screen. The projectors are constantly projecting images captured by the corresponding cameras onto the screen. The screen rotates around an in-plane vertical axis at a sufficient speed so that it faces each of the projectors in sequence. Since the Lambertian surfaces of the screens are covered by light-collimating plastic films with vertical louver patterns that are used for the selection of appropriate light rays, viewers can only observe images from a projector located in the same direction as the viewer. Thus, the dynamic view of an object is dependent on the viewer's head position. We evaluated the system by projecting both objects and human figures and confirmed that the entire system can reproduce light fields with a horizontal parallax to display video sequences of 430x770 pixels at a frame rate of 45 fps. Applications of this system include product design reviews, sales promotion, art exhibits, fashion shows, and sports training with form checking.
Automation of a high-speed imaging setup for differential viscosity measurements
NASA Astrophysics Data System (ADS)
Hurth, C.; Duane, B.; Whitfield, D.; Smith, S.; Nordquist, A.; Zenhausern, F.
2013-12-01
We present the automation of a setup previously used to assess the viscosity of pleural effusion samples and discriminate between transudates and exudates, an important first step in clinical diagnostics. The presented automation includes the design, testing, and characterization of a vacuum-actuated loading station that handles the 2 mm glass spheres used as sensors, as well as the engineering of electronic Printed Circuit Board (PCB) incorporating a microcontroller and their synchronization with a commercial high-speed camera operating at 10 000 fps. The hereby work therefore focuses on the instrumentation-related automation efforts as the general method and clinical application have been reported earlier [Hurth et al., J. Appl. Phys. 110, 034701 (2011)]. In addition, we validate the performance of the automated setup with the calibration for viscosity measurements using water/glycerol standard solutions and the determination of the viscosity of an "unknown" solution of hydroxyethyl cellulose.
Automation of a high-speed imaging setup for differential viscosity measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurth, C.; Duane, B.; Whitfield, D.
We present the automation of a setup previously used to assess the viscosity of pleural effusion samples and discriminate between transudates and exudates, an important first step in clinical diagnostics. The presented automation includes the design, testing, and characterization of a vacuum-actuated loading station that handles the 2 mm glass spheres used as sensors, as well as the engineering of electronic Printed Circuit Board (PCB) incorporating a microcontroller and their synchronization with a commercial high-speed camera operating at 10 000 fps. The hereby work therefore focuses on the instrumentation-related automation efforts as the general method and clinical application have beenmore » reported earlier [Hurth et al., J. Appl. Phys. 110, 034701 (2011)]. In addition, we validate the performance of the automated setup with the calibration for viscosity measurements using water/glycerol standard solutions and the determination of the viscosity of an “unknown” solution of hydroxyethyl cellulose.« less
Bayes filter modification for drivability map estimation with observations from stereo vision
NASA Astrophysics Data System (ADS)
Panchenko, Aleksei; Prun, Viktor; Turchenkov, Dmitri
2017-02-01
Reconstruction of a drivability map for a moving vehicle is a well-known research topic in applied robotics. Here creating such a map for an autonomous truck on a generally planar surface containing separate obstacles is considered. The source of measurements for the truck is a calibrated pair of cameras. The stereo system detects and reconstructs several types of objects, such as road borders, other vehicles, pedestrians and general tall objects or highly saturated objects (e.g. road cone). For creating a robust mapping module we use a modification of Bayes filtering, which introduces some novel techniques for occupancy map update step. Specifically, our modified version becomes applicable to the presence of false positive measurement errors, stereo shading and obstacle occlusion. We implemented the technique and achieved real-time 15 FPS computations on an industrial shake proof PC. Our real world experiments show the positive effect of the filtering step.
NASA Technical Reports Server (NTRS)
Springfield, C. W., Jr.
1985-01-01
The space telescope contains various scientific instrument (SI) modules which are mounted to the Focal Plane Structure (FPS) in a statically determinate manner. This is accomplished by using three registration fittings per SI module, one resisting three translations, another resisting two and the third resisting only one. Due to thermal insulating requirements these fittings are complex devices composed of numerous pieces. The structural integrity of these fittings is of great importance to the safety of the orbiter transporting the telescope, so in addition to the stress analyses performed during the design of these components, fracture susceptibility also needs to be considered. The pieces of the registration fittings for the Radial SI Module containing the Wide Field Planetary Camera are examined to determine which would endanger the orbiter if they fractured and what is the likelihood of their fracture. The latter is stated in terms of maximum allowable initial flaw sizes in these pieces.
High speed digital holography for density and fluctuation measurements (invited).
Thomas, C E; Baylor, L R; Combs, S K; Meitner, S J; Rasmussen, D A; Granstedt, E M; Majeski, R P; Kaita, R
2010-10-01
The state of the art in electro-optics has advanced to the point where digital holographic acquisition of wavefronts is now possible. Holographic wavefront acquisition provides the phase of the wavefront at every measurement point. This can be done with accuracy on the order of a thousandth of a wavelength, given that there is sufficient care in the design of the system. At wave frequencies which are much greater than the plasma frequency, the plasma index of refraction is linearly proportional to the electron density and wavelength, and the measurement of the phase of a wavefront passing through the plasma gives the chord-integrated density directly for all points measured on the wavefront. High-speed infrared cameras (up to ∼40,000 fps at ∼64×4 pixels) with resolutions up to 640×512 pixels suitable for use with a CO(2) laser are readily available, if expensive.
Preliminary design of a tangentially viewing imaging bolometer for NSTX-U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, B. J., E-mail: peterson@LHD.nifs.ac.jp; Mukai, K.; SOKENDAI
2016-11-15
The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm{sup 2} for a timemore » resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm{sup 2}.« less
fastSIM: a practical implementation of fast structured illumination microscopy.
Lu-Walther, Hui-Wen; Kielhorn, Martin; Förster, Ronny; Jost, Aurélie; Wicker, Kai; Heintzmann, Rainer
2015-01-16
A significant improvement in acquisition speed of structured illumination microscopy (SIM) opens a new field of applications to this already well-established super-resolution method towards 3D scanning real-time imaging of living cells. We demonstrate a method of increased acquisition speed on a two-beam SIM fluorescence microscope with a lateral resolution of ~100 nm at a maximum raw data acquisition rate of 162 frames per second (fps) with a region of interest of 16.5 × 16.5 µm 2 , free of mechanically moving components. We use a programmable spatial light modulator (ferroelectric LCOS) which promises precise and rapid control of the excitation pattern in the sample plane. A passive Fourier filter and a segmented azimuthally patterned polarizer are used to perform structured illumination with maximum contrast. Furthermore, the free running mode in a modern sCMOS camera helps to achieve faster data acquisition.
Recovery methods of the dragonfly from irregular initial conditions
NASA Astrophysics Data System (ADS)
Melfi, James; Leonardo, Anthony; Wang, Jane
We release dragonflies from a magnetic tether in a wide range of initial orientations, which results in them utilizing multiple methods to regain their typical flight orientation. Special focus is placed on dropping them while upside down, as the recovery method used is a purely rolling motion. Filming this stereotypical motion with a trio of high speed cameras at 4000 fps, we capture detailed body and wing kinematics data to determine how the dragonfly generates this motion. By replaying the flights within a computer simulation, we can isolate the significant changes to wing kinematics, and find that it is an asymmetry in the wing pitch which generates the roll. Further investigation demonstrates that this choice is highly dependent upon the state of the dragonfly, and as such our results indicate the dragonfly both tracks its current state, and changes its mid-flight control mechanisms accordingly.
Evaluation of skin pathologies by RGB autofluorescence imaging
NASA Astrophysics Data System (ADS)
Lihachev, Alexey; Plorina, Emilija V.; Derjabo, Alexander; Lange, Marta; Lihacova, Ilze
2017-12-01
A clinical trial on autofluorescence imaging of malignant and non-malignant skin pathologies comprising 32 basal cell carcinomas (BCC), 4 malignant melanomas (MM), 1 squamous cell carcinoma (SCC), 89 nevi, 14 dysplastic nevi, 20 hemangiomas, 23 seborrheic keratoses, 4 hyperkeratoses, 3 actinic keratoses, 3 psoriasis, 1 dematitis, 2 dermatofibromas, 5 papillofibromas, 12 lupus erythematosus, 7 purpura, 6 bruises, 5 freckles, 3 fungal infections, 1 burn, 1 tattoo, 1 age spot, 1 vitiligo, 32 postoperative scars, 8 post cream therapy BCCs, 4 post radiation therapy scars, 2 post laser therapy scars, 1 post freezing scar as well as 114 reference images of healthy skin was performed. The sequence of autofluorescence images of skin pathologies were recorded by smartphone RGB camera under continuous 405 nm LED excitation during 20 seconds with 0.5 fps. Obtained image sequences further were processed with subsequent extraction of autofluorescence intensity and photobleaching parameters.
Heo, Young Jin; Lee, Donghyeon; Kang, Junsu; Lee, Keondo; Chung, Wan Kyun
2017-09-14
Imaging flow cytometry (IFC) is an emerging technology that acquires single-cell images at high-throughput for analysis of a cell population. Rich information that comes from high sensitivity and spatial resolution of a single-cell microscopic image is beneficial for single-cell analysis in various biological applications. In this paper, we present a fast image-processing pipeline (R-MOD: Real-time Moving Object Detector) based on deep learning for high-throughput microscopy-based label-free IFC in a microfluidic chip. The R-MOD pipeline acquires all single-cell images of cells in flow, and identifies the acquired images as a real-time process with minimum hardware that consists of a microscope and a high-speed camera. Experiments show that R-MOD has the fast and reliable accuracy (500 fps and 93.3% mAP), and is expected to be used as a powerful tool for biomedical and clinical applications.
NASA Astrophysics Data System (ADS)
Zhang, Shuiqiang; Mao, Shuangshuang; Arola, Dwayne; Zhang, Dongsheng
2014-09-01
Characterizing the strain-life fatigue behavior of thin sheet metals is often challenging since the required specimens have short gauge lengths to avoid buckling, thereby preventing the use of conventional mechanical extensometers. To overcome this obstacle a microscopic optical imaging system has been developed to measure the strain amplitude during fatigue testing using Digital Image Correlation (DIC). A strategy for rapidly recording images is utilized to enable sequential image sampling rates of at least 10 frames per second (fps) using a general digital camera. An example of a complete strain-life fatigue test for thin sheet steel under constant displacement control is presented in which the corresponding strain within the gage section of the specimen is measured using the proposed imaging system. The precision in strain measurement is assessed and methods for improving the image sampling rates in dynamic testing are discussed.
fastSIM: a practical implementation of fast structured illumination microscopy
NASA Astrophysics Data System (ADS)
Lu-Walther, Hui-Wen; Kielhorn, Martin; Förster, Ronny; Jost, Aurélie; Wicker, Kai; Heintzmann, Rainer
2015-03-01
A significant improvement in acquisition speed of structured illumination microscopy (SIM) opens a new field of applications to this already well-established super-resolution method towards 3D scanning real-time imaging of living cells. We demonstrate a method of increased acquisition speed on a two-beam SIM fluorescence microscope with a lateral resolution of ~100 nm at a maximum raw data acquisition rate of 162 frames per second (fps) with a region of interest of 16.5 × 16.5 µm2, free of mechanically moving components. We use a programmable spatial light modulator (ferroelectric LCOS) which promises precise and rapid control of the excitation pattern in the sample plane. A passive Fourier filter and a segmented azimuthally patterned polarizer are used to perform structured illumination with maximum contrast. Furthermore, the free running mode in a modern sCMOS camera helps to achieve faster data acquisition.
Preliminary design of a tangentially viewing imaging bolometer for NSTX-U
Peterson, B. J.; Sano, R.; Reinke, M. L.; ...
2016-08-03
The InfraRed imaging Video Bolometer measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 x 480 (1280 x 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm x 9 cm x 2 μm Pt foil. The foil is divided into 40 x 40 (64 x 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm 2 for a time resolutionmore » of 33 (20) ms. Synthetic images derived from SOLPS data using the IRVB geometry show peak signal levels ranging from ~0.8 - ~80 (~0.36 - ~26) mW/cm 2.« less
DE-Sync: A Doppler-Enhanced Time Synchronization for Mobile Underwater Sensor Networks.
Zhou, Feng; Wang, Qi; Nie, DongHu; Qiao, Gang
2018-05-25
Time synchronization is the foundation of cooperative work among nodes of underwater sensor networks; it takes a critical role in the research and application of underwater sensor networks. Although numerous time synchronization protocols have been proposed for terrestrial wireless sensor networks, they cannot be directly applied to underwater sensor networks. This is because most of them typically assume that the propagation delay among sensor nodes is negligible, which is not the case in underwater sensor networks. Time synchronization is mainly affected by a long propagation delay among sensor nodes due to the low propagation speed of acoustic signals. Furthermore, sensor nodes in underwater tend to experience some degree of mobility due to wind or ocean current, or some other nodes are on self-propelled vehicles, such as autonomous underwater vehicles (AUVs). In this paper, we propose a Doppler-enhanced time synchronization scheme for mobile underwater sensor networks, called DE-Sync. Our new scheme considers the effect of the clock skew during the process of estimating the Doppler scale factor and directly substitutes the Doppler scale factor into linear regression to achieve the estimation of the clock skew and offset. Simulation results show that DE-Sync outperforms existing time synchronization protocols in both accuracy and energy efficiency.
Anton, Marja E; Baskin-Sommers, Arielle R; Vitale, Jennifer E; Curtin, John J; Newman, Joseph P
2012-12-01
Psychopathy and antisocial personality disorder (APD) have long been considered important risk factors for criminal behavior and incarceration. However, little is known about the psychobiological underpinnings that give rise to the disinhibited behavior of female offenders. Using an instructed fear-conditioning paradigm and a sample of incarcerated female offenders, we manipulated attentional focus and cognitive load to characterize and differentiate between the dysfunctional cognitive and affective processes associated with these syndromes. We used fear-potentiated startle (FPS) and event-related potentials as measures of affective and cognitive processing, respectively. After controlling for APD symptoms, psychopathic women displayed greater FPS while attending directly to threat-relevant stimuli and displayed less FPS while performing a demanding task that directed attention to threat-irrelevant information. Conversely, controlling for psychopathy, women with high APD symptoms displayed less overall FPS, especially when instructed to focus on threat-relevant stimuli. However, as the demands on cognitive resources increased, they displayed greater FPS. For both psychopathy and APD, analysis of the event-related potentials qualified these findings and further specified the abnormal cognitive processes associated with these two syndromes. Overall, simultaneous analysis of psychopathy and APD revealed distinct patterns of cognitive processing and fear reactivity.
Clements, Mark A.; Staggs, Vincent S.
2017-01-01
Background: Many individuals with type 1 diabetes (T1D) upload and review blood glucose data between clinic visits. Mobile phone applications that receive data from a “connected” glucometer and that support pattern management are available and have the capacity to make data upload and review less burdensome. Whether mobile apps can improve diabetes self-management among individuals with type 1 diabetes remains unknown. Method: We analyzed retrospective data on 81 youths with T1D who were trained to use a glucometer-connected mobile app in their self-management. To assess the effect of glucometer synchronization (“sync”) rate on hemoglobin A1c (HbA1c), mean blood glucose (mBG), and daily frequency of SMBG, we regressed those clinical outcomes on the frequency of glucometer syncs with the mobile app after controlling for other clinical care variables. Results: Median age was 14.0 (IQR 10.4-15.9) years, median duration of diabetes was 4.9 (2.7, 7.5) years, and median baseline HbA1c was 8.6% (7.9, 9.8). The sample was 49% male and 86% white. Youths with T1D synchronized glucometer data with the mobile app an average of 0.22 times per week (range 0-2.25). The glucometer sync rate did not have a statistically significant association with HbA1c or mean BG; in contrast, data sync frequency was associated with the frequency of self-monitoring of blood glucose (SMBG) such that each additional sync was associated with a 2.3-fold increase in SMBG frequency (P < .01). Conclusion: A glucometer-connected mobile app may increase an individual’s engagement with other aspects of care (eg, SMBG frequency). Whether diabetes device-connected mobile apps can improve glycemic control remains to be determined. PMID:28745097
NASA Astrophysics Data System (ADS)
Shiinoki, Takehiro; Onizuka, Ryota; Kawahara, Daisuke; Suzuki, Tatsuhiko; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Hanazawa, Hideki; Shibuya, Keiko
2018-03-01
Purpose: To quantify the patient-specific imaging dose for real-time tumour monitoring in the lung during respiratory-gated stereotactic body radiotherapy (SBRT) in clinical cases using SyncTraX. Methods and Materials: Ten patients who underwent respiratory-gated SBRT with SyncTraX were enrolled in this study. The imaging procedure for real-time tumour monitoring using SyncTraX was simulated using Monte Carlo. We evaluated the dosimetric effect of a real-time tumour monitoring in a critical organ at risk (OAR) and the planning target volume (PTV) over the course of treatment. The relationship between skin dose and gating efficiency was also investigated. Results: For all patients, the mean D50 to the PTV, ipsilateral lung, liver, heart, spinal cord and skin was 118.3 (21.5–175.9), 31.9 (9.5–75.4), 15.4 (1.1–31.6), 10.1 (1.3–18.1), 25.0 (1.6–101.8), and 3.6 (0.9–7.1) mGy, respectively. The mean D2 was 352.0 (26.5–935.8), 146.4 (27.3–226.7), 90.7 (3.6–255.0), 42.2 (4.8–82.7), 88.0 (15.4–248.5), and 273.5 (98.3–611.6) mGy, respectively. The D2 of the skin dose was found to increase as the gating efficiency decreased. Conclusions: The additional dose to the PTV was at most 1.9% of the prescribed dose over the course of treatment for real-time tumour monitoring. For OARs, we could confirm the high dose region, which may not be susceptible to radiation toxicity. However, to reduce the skin dose from SyncTraX, it is necessary to increase the gating efficiency.
Varma, Niraj; O'Donnell, David; Bassiouny, Mohammed; Ritter, Philippe; Pappone, Carlo; Mangual, Jan; Cantillon, Daniel; Badie, Nima; Thibault, Bernard; Wisnoskey, Brian
2018-02-06
QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [ P <0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Le May, Sylvie; Ballard, Ariane; Khadra, Christelle; Gouin, Serge; Plint, Amy C; Villeneuve, Edith; Mâsse, Benoit; Tsze, Daniel S; Neto, Gina; Drendel, Amy L; Auclair, Marie-Christine; McGrath, Patrick J; Ali, Samina
2018-03-30
Appropriate pain measurement relies on the use of valid, reliable tools. The aim of this study was to determine and compare the psychometric properties of 3 self-reported pain scales commonly used in the pediatric emergency department (ED). The inclusion criteria were children aged 6 to 17 years presenting to the ED with a musculoskeletal injury and self-reported pain scores ≥30 mm on the mechanical Visual Analogue Scale (VAS). Self-reported pain intensity was assessed using the mechanical VAS, Faces Pain Scale-Revised (FPS-R), and Colour Analogue Scale (CAS). Convergent validity was assessed by Pearson correlations and the Bland-Altman method; responsiveness to change was assessed using paired sample t tests and standardized mean responses; and reliability was estimated using relative and absolute indices. A total of 456 participants were included, with a mean age of 11.9 years ± 2.7 and a majority were boys (252/456, 55.3%). Correlations between each pair of scales were 0.78 (VAS/FPS-R), 0.92 (VAS/CAS), and 0.79 (CAS/FPS-R). Limits of agreement (95% confidence interval) were -3.77 to 2.33 (VAS/FPS-R), -1.74 to 1.75 (VAS/CAS), and -2.21 to 3.62 (CAS/FPS-R). Responsiveness to change was demonstrated by significant differences in mean pain scores among the scales (P < 0.0001). Intraclass correlation coefficient and coefficient of repeatability estimates suggested acceptable reliability for the 3 scales at, respectively, 0.79 and ±2.29 (VAS), 0.82 and ±2.07 (CAS), and 0.76 and ±2.82 (FPS-R). The scales demonstrated good psychometric properties for children with acute pain in the ED. The VAS and CAS showed a strong convergent validity, whereas FPS-R was not in agreement with the other scales.
Characterization of flavin-based fluorescent proteins: an emerging class of fluorescent reporters.
Mukherjee, Arnab; Walker, Joshua; Weyant, Kevin B; Schroeder, Charles M
2013-01-01
Fluorescent reporter proteins based on flavin-binding photosensors were recently developed as a new class of genetically encoded probes characterized by small size and oxygen-independent maturation of fluorescence. Flavin-based fluorescent proteins (FbFPs) address two major limitations associated with existing fluorescent reporters derived from the green fluorescent protein (GFP)-namely, the overall large size and oxygen-dependent maturation of fluorescence of GFP. However, FbFPs are at a nascent stage of development and have been utilized in only a handful of biological studies. Importantly, a full understanding of the performance and properties of FbFPs as a practical set of biological probes is lacking. In this work, we extensively characterize three FbFPs isolated from Pseudomonas putida, Bacillus subtilis, and Arabidopsis thaliana, using in vitro studies to assess probe brightness, oligomeric state, maturation time, fraction of fluorescent holoprotein, pH tolerance, redox sensitivity, and thermal stability. Furthermore, we validate FbFPs as stable molecular tags using in vivo studies by constructing a series of FbFP-based transcriptional constructs to probe promoter activity in Escherichia coli. Overall, FbFPs show key advantages as broad-spectrum biological reporters including robust pH tolerance (4-11), thermal stability (up to 60°C), and rapid maturation of fluorescence (<3 min.). In addition, the FbFP derived from Arabidopsis thaliana (iLOV) emerged as a stable and nonperturbative reporter of promoter activity in Escherichia coli. Our results demonstrate that FbFP-based reporters have the potential to address key limitations associated with the use of GFP, such as pH-sensitive fluorescence and slow kinetics of fluorescence maturation (10-40 minutes for half maximal fluorescence recovery). From this view, FbFPs represent a useful new addition to the fluorescent reporter protein palette, and our results constitute an important framework to enable researchers to implement and further engineer improved FbFP-based reporters with enhanced brightness and tighter flavin binding, which will maximize their potential benefits.
NASA Astrophysics Data System (ADS)
Verkaik, J.
2013-12-01
The Netherlands Hydrological Instrument (NHI) model predicts water demands in periods of drought, supporting the Dutch decision makers in taking operational as well as long-term decisions with respect to the water supply. Other applications of NHI are predicting fresh-salt interaction, nutrient loadings, and agriculture change. The NHI model consists of several coupled models: a saturated groundwater model (MODFLOW), an unsaturated groundwater model (MetaSWAP), a sub-catchment surface water model (MOZART), and a distribution network of surface waters model (DM/SOBEK). Each of these models requires specific, usually large, input data that may be the result of sophisticated schematization workflows. Input data can also be dependent on each other, for example, the precipitation data is input for the unsaturated zone model (cells) as well as for the surface water models (polygons). For efficient data management, we developed several Python tools such that the modeler or stakeholder can use the model in a user-friendly manner, and data is managed in a consistent, transparent and reproducible way. Two open source Python tools are presented here: the data version control module for the workflow manager VisTrails called FileSync, and the NHI model control script that uses FileSync. VisTrails is an open-source scientific workflow and provenance management system that provides support for simulations, data exploration and visualization. Since VisTrails does not directly support version control we developed a version control module called FileSync. With this generic module, the user can synchronize data from and to his workflow through a dialog window. The FileSync dialog calls the FileSync script that is command-line based and performs the actual data synchronization. This script allows the user to easily create a model repository, upload and download data, create releases and define scenarios. The data synchronization approach applied here differs from systems as Subversion or Git, since these systems do not perform well for large (binary) model data files. For this reason, a new concept of parameterization and data splitting has been implemented. Each file, or set of files, is uniquely labeled as a parameter, and for this parameter metadata is maintained by Subversion. The metadata data contains file hashes to identify data content and the location where the actual bulk data are stored that can be reached by FTP. The NHI model control script is a command-line driven Python script for pre-processing, running, and post-processing the NHI model and uses one single configuration file for all computational kernels. This configuration file is an easy-to-use, keyword-driven, Windows INI-file, having separate sections for all the kernels. It also includes a FileSync data section where the user can specify version controlled model data to be used as input. The NHI control script keeps all the data consistent during the pre-processing. Furthermore, this script is able to do model state handling when the NHI model is used for ensemble forecasting.
6. INTERIOR OF THE MAIN EQUIPMENT ROOM, AN/FPS66 ALPHA, BUILDING ...
6. INTERIOR OF THE MAIN EQUIPMENT ROOM, AN/FPS66 ALPHA, BUILDING 408, LOOKING WEST. - Mill Valley Air Force Station, Operations Building & Annex, East Ridgecrest Boulevard, Mount Tamalpais, Mill Valley, Marin County, CA
Playing a first-person shooter video game induces neuroplastic change.
Wu, Sijing; Cheng, Cho Kin; Feng, Jing; D'Angelo, Lisa; Alain, Claude; Spence, Ian
2012-06-01
Playing a first-person shooter (FPS) video game alters the neural processes that support spatial selective attention. Our experiment establishes a causal relationship between playing an FPS game and neuroplastic change. Twenty-five participants completed an attentional visual field task while we measured ERPs before and after playing an FPS video game for a cumulative total of 10 hr. Early visual ERPs sensitive to bottom-up attentional processes were little affected by video game playing for only 10 hr. However, participants who played the FPS video game and also showed the greatest improvement on the attentional visual field task displayed increased amplitudes in the later visual ERPs. These potentials are thought to index top-down enhancement of spatial selective attention via increased inhibition of distractors. Individual variations in learning were observed, and these differences show that not all video game players benefit equally, either behaviorally or in terms of neural change.
Panaitescu, Catalina; Moffat, Mandy A; Williams, Siân; Pinnock, Hilary; Boros, Melinda; Oana, Cristian Sever; Alexiu, Sandra; Tsiligianni, Ioanna
2014-01-01
Background: Smoking cessation is the most effective intervention to prevent and slow down the progression of several respiratory and other diseases and improve patient outcomes. Romania has legislation and a national tobacco control programme in line with the World Health Organization Framework for Tobacco Control. However, few smokers are advised to quit by their family physicians (FPs). Aim: To identify and explore the perceived barriers that prevent Romanian FPs from engaging in smoking cessation with patients. Methods: A qualitative study was undertaken. A total of 41 FPs were recruited purposively from Bucharest and rural areas within 600 km of the city. Ten FPs took part in a focus group and 31 participated in semistructured interviews. Analysis was descriptive, inductive and themed, according to the barriers experienced. Results: Five main barriers were identified: limited perceived role for FPs; lack of time during consultations; past experience and presence of disincentives; patients’ inability to afford medication; and lack of training in smoking cessation skills. Overarching these specific barriers were key themes of a medical and societal hierarchy, which undermined the FP role, stretched resources and constrained care. Conclusions: Many of the barriers described by the Romanian FPs reflected universally recognised challenges to the provision of smoking cessation advice. The context of a relatively hierarchical health-care system and limitations of time and resources exacerbated many of the problems and created new barriers that will need to be addressed if Romania is to achieve the aims of its National Programme Against Tobacco Consumption. PMID:25010432
Çiçeklioğlu, Meltem; Öcek, Zeliha Aslı; Turk, Meral; Taner, Şafak
2015-06-01
Turkey has undergone a 'Health transformation programme' putting emphasis on the reorganization of primary care (PC) services towards a more market-oriented system. To obtain a deep understanding of how family physicians (FPs) experienced the process of the reforms by focusing on working conditions. This phenomenological and qualitative research used maximum variation sampling and 51 FPs were interviewed in 36 in-depth and four focus-group interviews. Thematic analysis of interviews provided seven themes: (1) change in the professional identity of PC physicians (physician as businessperson); (2) transformation of the physician-patient relationship in PC (into a provider-customer relationship); (3) job description and workload; (4) interpersonal relationships; (5) remuneration of FPs, (6) uncertainty about the future and (7) exhaustion. Most FPs felt that the Family medicine model (FMM) placed more emphasis on the business function of family practice and this conflicted with their professional characteristics as physicians. FPs complained that some of their patients behaved as extremely demanding consumers. Continuously increasing responsibilities and extremely high workload were commonly reported problems. Most participants described the negative incentives in the performance scheme as a degrading method of punishment. The main factor was job insecurity caused by contract-based employment. FPs described the point at which they are with terms such as exhaustion. By increasing workload and creating uncertainty about the future and about income, the PC reforms have led to working conditions, which has led to changes in the professional attitudes of physicians and their practice of medicine.
Trivedi, Mehul A; Coover, Gary D
2006-04-03
Pavlovian delay conditioning, in which a conditioned stimulus (CS) and unconditioned stimulus (US) co-terminate, is thought to reflect non-declarative memory. In contrast, trace conditioning, in which the CS and US are temporally separate, is thought to reflect declarative memory. Hippocampal lesions impair acquisition and expression of trace conditioning measured by the conditioned freezing and eyeblink responses, while having little effect on the acquisition of delay conditioning. Recent evidence suggests that lesions of the ventral hippocampus (VH) impair conditioned fear under conditions in which dorsal hippocampal (DH) lesions have little effect. In the present study, we examined the time-course of fear expression after delay and trace conditioning using the fear-potentiated startle (FPS) reflex, and the effects of pre- and post-training lesions to the VH and DH on trace-conditioned FPS. We found that both delay- and trace-conditioned rats displayed significant FPS near the end of the CS relative to the unpaired control group. In contrast, trace-conditioned rats displayed significant FPS throughout the duration of the trace interval, whereas FPS decayed rapidly to baseline after CS offset in delay-conditioned rats. In experiment 2, both DH and VH lesions were found to significantly reduce the overall magnitude of FPS compared to the control group, however, no differences were found between the DH and VH groups. These findings support a role for both the DH and VH in trace fear conditioning, and suggest that the greater effect of VH lesions on conditioned fear might be specific to certain measures of fear.
NASA Astrophysics Data System (ADS)
Ahmed, Raheel; Edwards, Michael G.; Lamine, Sadok; Huisman, Bastiaan A. H.; Pal, Mayur
2017-11-01
Two novel control-volume methods are presented for flow in fractured media, and involve coupling the control-volume distributed multi-point flux approximation (CVD-MPFA) constructed with full pressure support (FPS), to two types of discrete fracture-matrix approximation for simulation on unstructured grids; (i) involving hybrid grids and (ii) a lower dimensional fracture model. Flow is governed by Darcy's law together with mass conservation both in the matrix and the fractures, where large discontinuities in permeability tensors can occur. Finite-volume FPS schemes are more robust than the earlier CVD-MPFA triangular pressure support (TPS) schemes for problems involving highly anisotropic homogeneous and heterogeneous full-tensor permeability fields. We use a cell-centred hybrid-grid method, where fractures are modelled by lower-dimensional interfaces between matrix cells in the physical mesh but expanded to equi-dimensional cells in the computational domain. We present a simple procedure to form a consistent hybrid-grid locally for a dual-cell. We also propose a novel hybrid-grid for intersecting fractures, for the FPS method, which reduces the condition number of the global linear system and leads to larger time steps for tracer transport. The transport equation for tracer flow is coupled with the pressure equation and provides flow parameter assessment of the fracture models. Transport results obtained via TPS and FPS hybrid-grid formulations are compared with the corresponding results of fine-scale explicit equi-dimensional formulations. The results show that the hybrid-grid FPS method applies to general full-tensor fields and provides improved robust approximations compared to the hybrid-grid TPS method for fractured domains, for both weakly anisotropic permeability fields and very strong anisotropic full-tensor permeability fields where the TPS scheme exhibits spurious oscillations. The hybrid-grid FPS formulation is extended to compressible flow and the results demonstrate the method is also robust for transient flow. Furthermore, we present FPS coupled with a lower-dimensional fracture model, where fractures are strictly lower-dimensional in the physical mesh as well as in the computational domain. We present a comparison of the hybrid-grid FPS method and the lower-dimensional fracture model for several cases of isotropic and anisotropic fractured media which illustrate the benefits of the respective methods.
Haq, Rashida; Heus, Lineke; Baker, Natalie A; Dastur, Daisy; Leung, Fok-Han; Leung, Eman; Li, Benjamin; Vu, Kathy; Parsons, Janet A
2013-07-25
Following the completion of treatment and as they enter the follow-up phase, breast cancer patients (BCPs) often recount feeling 'lost in transition', and are left with many questions concerning how their ongoing care and monitoring for recurrence will be managed. Family physicians (FPs) also frequently report feeling ill-equipped to provide follow-up care to BCPs. In this three-phase qualitative pilot study we designed, implemented and evaluated a multi-faceted survivorship care plan (SCP) to address the information needs of BCPs at our facility and of their FPs. In Phase 1 focus groups and individual interviews were conducted with 35 participants from three stakeholder groups (BCPs, FPs and oncology specialist health care providers (OHCPs)), to identify specific information needs. An SCP was then designed based on these findings, consisting of both web-based and paper-based tools (Phase 2). For Phase 3, both sets of tools were subsequently evaluated via focus groups and interviews with 26 participants. Interviews and focus groups were audio taped, transcribed and content analysed for emergent themes and patterns. In Phase 1 patients commented that web-based, paper-based and human resources components were desirable in any SCP. Patients did not focus exclusively on the post-treatment period, but instead spoke of evolving needs throughout their cancer journey. FPs indicated that any tools to support them must distill important information in a user-friendly format. In Phase 2, a pilot SCP was subsequently designed, consisting of both web-based and paper-based materials tailored specifically to the needs of BCPs as well as FPs. During Phase 3 (evaluation) BCPs indicated that the SCP was effective at addressing many of their needs, and offered suggestions for future improvements. Both patients and FPs found the pilot SCP to be an improvement from the previous standard of care. Patients perceived the quality of the BCP-FP relationship as integral to their comfort with FPs assuming follow-up responsibilities. This pilot multi-component SCP shows promise in addressing the information needs of BCPs and the FPs who care for them. Next steps include refinement of the different SCP components, further evaluation (including usability testing), and planning for more extensive implementation.
Field-based high-speed imaging of explosive eruptions
NASA Astrophysics Data System (ADS)
Taddeucci, J.; Scarlato, P.; Freda, C.; Moroni, M.
2012-12-01
Explosive eruptions involve, by definition, physical processes that are highly dynamic over short time scales. Capturing and parameterizing such processes is a major task in eruption understanding and forecasting, and a task that necessarily requires observational systems capable of high sampling rates. Seismic and acoustic networks are a prime tool for high-frequency observation of eruption, recently joined by Doppler radar and electric sensors. In comparison with the above monitoring systems, imaging techniques provide more complete and direct information of surface processes, but usually at a lower sampling rate. However, recent developments in high-speed imaging systems now allow such information to be obtained with a spatial and temporal resolution suitable for the analysis of several key eruption processes. Our most recent set up for high-speed imaging of explosive eruptions (FAMoUS - FAst, MUltiparametric Set-up,) includes: 1) a monochrome high speed camera, capable of 500 frames per second (fps) at high-definition (1280x1024 pixel) resolution and up to 200000 fps at reduced resolution; 2) a thermal camera capable of 50-200 fps at 480-120x640 pixel resolution; and 3) two acoustic to infrasonic sensors. All instruments are time-synchronized via a data logging system, a hand- or software-operated trigger, and via GPS, allowing signals from other instruments or networks to be directly recorded by the same logging unit or to be readily synchronized for comparison. FAMoUS weights less than 20 kg, easily fits into four, hand-luggage-sized backpacks, and can be deployed in less than 20' (and removed in less than 2', if needed). So far, explosive eruptions have been recorded in high-speed at several active volcanoes, including Fuego and Santiaguito (Guatemala), Stromboli (Italy), Yasur (Vanuatu), and Eyjafiallajokull (Iceland). Image processing and analysis from these eruptions helped illuminate several eruptive processes, including: 1) Pyroclasts ejection. High-speed videos reveal multiple, discrete ejection pulses within a single Strombolian explosion, with ejection velocities twice as high as previously recorded. Video-derived information on ejection velocity and ejecta mass can be combined with analytical and experimental models to constrain the physical parameters of the gas driving individual pulses. 2) Jet development. The ejection trajectory of pyroclasts can also be used to outline the spatial and temporal development of the eruptive jet and the dynamics of gas-pyroclast coupling within the jet, while high-speed thermal images add information on the temperature evolution in the jet itself as a function of the pyroclast size and content. 2) Pyroclasts settling. High-speed videos can be used to investigate the aerodynamic settling behavior of pyroclasts from bomb to ash in size and including ash aggregates, providing key parameters such as drag coefficient as a function of Re, and particle density. 3) The generation and propagation of acoustic and shock waves. Phase condensation in volcanic and atmospheric aerosol is triggered by the transit of pressure waves and can be recorded in high-speed videos, allowing the speed and wavelength of the waves to be measured and compared with the corresponding infrasonic signals and theoretical predictions.
A Guide to Fluorescent Protein FRET Pairs
Bajar, Bryce T.; Wang, Emily S.; Zhang, Shu; Lin, Michael Z.; Chu, Jun
2016-01-01
Förster or fluorescence resonance energy transfer (FRET) technology and genetically encoded FRET biosensors provide a powerful tool for visualizing signaling molecules in live cells with high spatiotemporal resolution. Fluorescent proteins (FPs) are most commonly used as both donor and acceptor fluorophores in FRET biosensors, especially since FPs are genetically encodable and live-cell compatible. In this review, we will provide an overview of methods to measure FRET changes in biological contexts, discuss the palette of FP FRET pairs developed and their relative strengths and weaknesses, and note important factors to consider when using FPs for FRET studies. PMID:27649177
Miyoshi, Hirokazu; Hiroura, Mitsunori; Tsujimoto, Kazunori; Irikura, Namiko; Otani, Tamaki; Shinohara, Yasuo
2017-05-01
A new scintillation imaging material [scintillator-silica fine powder (FP)] was prepared using silica FPs and scintillator-encapsulating silica nanoparticles (NPs) (scintillator-silica NPs). The wt% values of scintillator-silica NPs on the scintillator-silica FPs were 38, 43, 36 and 44%. Scintillation images of 3H, 63Ni, 35S, 33P, 204Tl, 89Sr and 32P dropped on the scintillator-silica FPs were obtained at about 37 kBq per 0.1-10 µl with a charge-coupled device (CCD) imager for a 5 min exposure. In particular, high-intensity CCD images of 35S were selectively obtained using the 2.25, 4.77 and 10 µm silica FPs with scintillator-silica NPs owing to the residual S of dimethyl sulfoxide in the preparation. Scintillation images of 3H at 1670 ± 9 Bq/0.5 µl and 347 ± 6 Bq/0.5 µl dropped in a 2 mm hole on the scintillator-silica FPs (6.78 and 10 µm) were also obtained using the CCD imager for a 2 h exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Anton, Marja E.; Vitale, Jennifer E.; Curtin, John J.; Newman, Joseph P.
2012-01-01
Psychopathy and antisocial personality disorder (APD) have long been considered important risk factors for criminal behavior and incarceration. However, little is known about the psychobiological underpinnings that give rise to the disinhibited behavior of female offenders. Using an instructed fear-conditioning paradigm and a sample of incarcerated female offenders, we manipulated attentional focus and cognitive load to characterize and differentiate between the dysfunctional cognitive and affective processes associated with these syndromes. We used fear-potentiated startle (FPS) and event-related potentials as measures of affective and cognitive processing, respectively. After controlling for APD symptoms, psychopathic women displayed greater FPS while attending directly to threat-relevant stimuli and displayed less FPS while performing a demanding task that directed attention to threat-irrelevant information. Conversely, controlling for psychopathy, women with high APD symptoms displayed less overall FPS, especially when instructed to focus on threat-relevant stimuli. However, as the demands on cognitive resources increased, they displayed greater FPS. For both psychopathy and APD, analysis of the event-related potentials qualified these findings and further specified the abnormal cognitive processes associated with these two syndromes. Overall, simultaneous analysis of psychopathy and APD revealed distinct patterns of cognitive processing and fear reactivity. PMID:22886692
NASA Technical Reports Server (NTRS)
Kast, J. R.
1988-01-01
The Upper Atmosphere Research Satellite (UARS) is a three-axis stabilized Earth-pointing spacecraft in a low-Earth orbit. The UARS onboard computer (OBC) uses a Fourier Power Series (FPS) ephemeris representation that includes 42 position and 42 velocity coefficients per axis, with position residuals at 10-minute intervals. New coefficients and 32 hours of residuals are uploaded daily. This study evaluated two backup methods that permit the OBC to compute an approximate spacecraft ephemeris in the event that new ephemeris data cannot be uplinked for several days: (1) extending the use of the FPS coefficients previously uplinked, and (2) switching to a simple circular orbit approximation designed and tested (but not implemented) for LANDSAT-D. The FPS method provides greater accuracy during the backup period and does not require additional ground operational procedures for generating and uplinking an additional ephemeris table. The tradeoff is that the high accuracy of the FPS will be degraded slightly by adopting the longer fit period necessary to obtain backup accuracy for an extended period of time. The results for UARS show that extended use of the FPS is superior to the circular orbit approximation for short-term ephemeris backup.
Gagnon, Susie; Labrecque, Michel; Njoya, Merlin; Rousseau, François; St-Jacques, Sylvie; Légaré, France
2010-02-01
To assess the extent to which family physicians (FPs) involve women in decisions about prenatal screening for Down syndrome. Based on transcripts of consultations between 41 FPs and 128 women, two raters independently assessed clinician's efforts to involve women in decisions about prenatal screening for Down syndrome using the French-language version of OPTION. Descriptive statistics of OPTION scores were calculated. Construct validity was assessed by performing a principal factor analysis and by measuring association with consultation duration and FPs sociodemograhics. Internal consistency was assessed with Cronbach's alpha and inter-rater reliability with the intraclass correlation coefficient. The overall mean OPTION score was low: 19 +/- 7 (range = 0 [no involvement] to 100 [high involvement]). One factor accounted for 80% of the variance. Both internal consistency and inter-rater reliability were very good (Cronbach's alpha = 0.73; ICC = 0.76). OPTION scores were lower for residents than for licensed FPs (17 +/- 5 vs 21 +/- 4; p = 0.02) and were positively associated with duration of consultation (r = 0.56; p < 0.001). Based on the French-language version of OPTION, which showed satisfactory psychometric properties, FPs studied put minimal efforts to involve women in decisions about prenatal screening for Down syndrome. (c) 2009 John Wiley & Sons, Ltd.
Traffic sign detection in MLS acquired point clouds for geometric and image-based semantic inventory
NASA Astrophysics Data System (ADS)
Soilán, Mario; Riveiro, Belén; Martínez-Sánchez, Joaquín; Arias, Pedro
2016-04-01
Nowadays, mobile laser scanning has become a valid technology for infrastructure inspection. This technology permits collecting accurate 3D point clouds of urban and road environments and the geometric and semantic analysis of data became an active research topic in the last years. This paper focuses on the detection of vertical traffic signs in 3D point clouds acquired by a LYNX Mobile Mapper system, comprised of laser scanning and RGB cameras. Each traffic sign is automatically detected in the LiDAR point cloud, and its main geometric parameters can be automatically extracted, therefore aiding the inventory process. Furthermore, the 3D position of traffic signs are reprojected on the 2D images, which are spatially and temporally synced with the point cloud. Image analysis allows for recognizing the traffic sign semantics using machine learning approaches. The presented method was tested in road and urban scenarios in Galicia (Spain). The recall results for traffic sign detection are close to 98%, and existing false positives can be easily filtered after point cloud projection. Finally, the lack of a large, publicly available Spanish traffic sign database is pointed out.
Malin, Michal C; Ravine, Michael A; Caplinger, Michael A; Tony Ghaemi, F; Schaffner, Jacob A; Maki, Justin N; Bell, James F; Cameron, James F; Dietrich, William E; Edgett, Kenneth S; Edwards, Laurence J; Garvin, James B; Hallet, Bernard; Herkenhoff, Kenneth E; Heydari, Ezat; Kah, Linda C; Lemmon, Mark T; Minitti, Michelle E; Olson, Timothy S; Parker, Timothy J; Rowland, Scott K; Schieber, Juergen; Sletten, Ron; Sullivan, Robert J; Sumner, Dawn Y; Aileen Yingst, R; Duston, Brian M; McNair, Sean; Jensen, Elsa H
2017-08-01
The Mars Science Laboratory Mast camera and Descent Imager investigations were designed, built, and operated by Malin Space Science Systems of San Diego, CA. They share common electronics and focal plane designs but have different optics. There are two Mastcams of dissimilar focal length. The Mastcam-34 has an f/8, 34 mm focal length lens, and the M-100 an f/10, 100 mm focal length lens. The M-34 field of view is about 20° × 15° with an instantaneous field of view (IFOV) of 218 μrad; the M-100 field of view (FOV) is 6.8° × 5.1° with an IFOV of 74 μrad. The M-34 can focus from 0.5 m to infinity, and the M-100 from ~1.6 m to infinity. All three cameras can acquire color images through a Bayer color filter array, and the Mastcams can also acquire images through seven science filters. Images are ≤1600 pixels wide by 1200 pixels tall. The Mastcams, mounted on the ~2 m tall Remote Sensing Mast, have a 360° azimuth and ~180° elevation field of regard. Mars Descent Imager is fixed-mounted to the bottom left front side of the rover at ~66 cm above the surface. Its fixed focus lens is in focus from ~2 m to infinity, but out of focus at 66 cm. The f/3 lens has a FOV of ~70° by 52° across and along the direction of motion, with an IFOV of 0.76 mrad. All cameras can acquire video at 4 frames/second for full frames or 720p HD at 6 fps. Images can be processed using lossy Joint Photographic Experts Group and predictive lossless compression.
Ravine, Michael A.; Caplinger, Michael A.; Tony Ghaemi, F.; Schaffner, Jacob A.; Maki, Justin N.; Bell, James F.; Cameron, James F.; Dietrich, William E.; Edgett, Kenneth S.; Edwards, Laurence J.; Garvin, James B.; Hallet, Bernard; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sletten, Ron; Sullivan, Robert J.; Sumner, Dawn Y.; Aileen Yingst, R.; Duston, Brian M.; McNair, Sean; Jensen, Elsa H.
2017-01-01
Abstract The Mars Science Laboratory Mast camera and Descent Imager investigations were designed, built, and operated by Malin Space Science Systems of San Diego, CA. They share common electronics and focal plane designs but have different optics. There are two Mastcams of dissimilar focal length. The Mastcam‐34 has an f/8, 34 mm focal length lens, and the M‐100 an f/10, 100 mm focal length lens. The M‐34 field of view is about 20° × 15° with an instantaneous field of view (IFOV) of 218 μrad; the M‐100 field of view (FOV) is 6.8° × 5.1° with an IFOV of 74 μrad. The M‐34 can focus from 0.5 m to infinity, and the M‐100 from ~1.6 m to infinity. All three cameras can acquire color images through a Bayer color filter array, and the Mastcams can also acquire images through seven science filters. Images are ≤1600 pixels wide by 1200 pixels tall. The Mastcams, mounted on the ~2 m tall Remote Sensing Mast, have a 360° azimuth and ~180° elevation field of regard. Mars Descent Imager is fixed‐mounted to the bottom left front side of the rover at ~66 cm above the surface. Its fixed focus lens is in focus from ~2 m to infinity, but out of focus at 66 cm. The f/3 lens has a FOV of ~70° by 52° across and along the direction of motion, with an IFOV of 0.76 mrad. All cameras can acquire video at 4 frames/second for full frames or 720p HD at 6 fps. Images can be processed using lossy Joint Photographic Experts Group and predictive lossless compression. PMID:29098171
NASA Astrophysics Data System (ADS)
Jridi, Maher; Alfalou, Ayman
2017-05-01
By this paper, the major goal is to investigate the Multi-CPU/FPGA SoC (System on Chip) design flow and to transfer a know-how and skills to rapidly design embedded real-time vision system. Our aim is to show how the use of these devices can be benefit for system level integration since they make possible simultaneous hardware and software development. We take the facial detection and pretreatments as case study since they have a great potential to be used in several applications such as video surveillance, building access control and criminal identification. The designed system use the Xilinx Zedboard platform. The last is the central element of the developed vision system. The video acquisition is performed using either standard webcam connected to the Zedboard via USB interface or several camera IP devices. The visualization of video content and intermediate results are possible with HDMI interface connected to HD display. The treatments embedded in the system are as follow: (i) pre-processing such as edge detection implemented in the ARM and in the reconfigurable logic, (ii) software implementation of motion detection and face detection using either ViolaJones or LBP (Local Binary Pattern), and (iii) application layer to select processing application and to display results in a web page. One uniquely interesting feature of the proposed system is that two functions have been developed to transmit data from and to the VDMA port. With the proposed optimization, the hardware implementation of the Sobel filter takes 27 ms and 76 ms for 640x480, and 720p resolutions, respectively. Hence, with the FPGA implementation, an acceleration of 5 times is obtained which allow the processing of 37 fps and 13 fps for 640x480, and 720p resolutions, respectively.
Lin, Jianyu; Clancy, Neil T; Qi, Ji; Hu, Yang; Tatla, Taran; Stoyanov, Danail; Maier-Hein, Lena; Elson, Daniel S
2018-06-15
Surgical guidance and decision making could be improved with accurate and real-time measurement of intra-operative data including shape and spectral information of the tissue surface. In this work, a dual-modality endoscopic system has been proposed to enable tissue surface shape reconstruction and hyperspectral imaging (HSI). This system centers around a probe comprised of an incoherent fiber bundle, whose fiber arrangement is different at the two ends, and miniature imaging optics. For 3D reconstruction with structured light (SL), a light pattern formed of randomly distributed spots with different colors is projected onto the tissue surface, creating artificial texture. Pattern decoding with a Convolutional Neural Network (CNN) model and a customized feature descriptor enables real-time 3D surface reconstruction at approximately 12 frames per second (FPS). In HSI mode, spatially sparse hyperspectral signals from the tissue surface can be captured with a slit hyperspectral imager in a single snapshot. A CNN based super-resolution model, namely "super-spectral-resolution" network (SSRNet), has also been developed to estimate pixel-level dense hypercubes from the endoscope cameras standard RGB images and the sparse hyperspectral signals, at approximately 2 FPS. The probe, with a 2.1 mm diameter, enables the system to be used with endoscope working channels. Furthermore, since data acquisition in both modes can be accomplished in one snapshot, operation of this system in clinical applications is minimally affected by tissue surface movement and deformation. The whole apparatus has been validated on phantoms and tissue (ex vivo and in vivo), while initial measurements on patients during laryngeal surgery show its potential in real-world clinical applications. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coughlin, Jeffrey L.; Thompson, Susan E.; Burke, Christopher J.
The Kepler mission has to date found almost 6000 planetary transit-like signals, utilizing three years of data for over 170,000 stars at extremely high photometric precision. Due to its design, contamination from eclipsing binaries, variable stars, and other transiting planets results in a significant number of these signals being false positives (FPs). This directly affects the determination of the occurrence rate of Earth-like planets in our Galaxy, as well as other planet population statistics. In order to detect as many of these FPs as possible, we perform ephemeris matching among all transiting planet, eclipsing binary, and variable star sources. Wemore » find that 685 Kepler Objects of Interest (KOIs)—12% of all those analyzed—are FPs as a result of contamination, due to 409 unique parent sources. Of these, 118 have not previously been identified by other methods. We estimate that ∼35% of KOIs are FPs due to contamination, when performing a first-order correction for observational bias. Comparing single-planet candidate KOIs to multi-planet candidate KOIs, we find an observed FP fraction due to contamination of 16% and 2.4% respectively, bolstering the existing evidence that multi-planet KOIs are significantly less likely to be FPs. We also analyze the parameter distributions of the ephemeris matches and derive a simple model for the most common type of contamination in the Kepler field. We find that the ephemeris matching technique is able to identify low signal-to-noise FPs that are difficult to identify with other vetting techniques. We expect FP KOIs to become more frequent when analyzing more quarters of Kepler data, and note that many of them will not be able to be identified based on Kepler data alone.« less
Jaakkimainen, R Liisa; Bondy, Susan J; Parkovnick, Meredith; Barnsley, Jan
2014-10-01
To compare how the infectious disease outbreaks H1N1 and severe acute respiratory syndrome (SARS) affected community-based GPs and FPs. A mailed survey sent after the H1N1 outbreak compared with the results of similar survey completed after the SARS outbreak. Greater Toronto area in Ontario. A total of 183 randomly selected GPs and FPs who provided office-based care. The perceptions of GPs and FPs on how serious infectious disease outbreaks affected their clinical work and personal lives; their preparedness for a serious infectious disease outbreak; and the types of information they want to receive and the sources they wanted to receive information from during a serious infectious disease outbreak. The responses from this survey were compared with the responses of GPs and FPs in the greater Toronto area who completed a similar survey in 2003 after the SARS outbreak. After the H1N1 outbreak, GPs and FPs still had substantial concerns about the effects of serious infectious disease outbreaks on the health of their family members. Physicians made changes to various office practices in order to manage and deal with patients with serious infectious diseases. They expressed concerns about the effects of an infectious disease on the provision of health care services. Also, physicians wanted to quickly receive accurate information from the provincial government and their medical associations. Serious community-based infectious diseases are a personal concern for GPs and FPs, and have considerable effects on their clinical practice. Further work examining the timely flow of relevant information through different health care sectors and government agencies still needs to be undertaken. Copyright© the College of Family Physicians of Canada.
Maternity Care Services Provided by Family Physicians in Rural Hospitals.
Young, Richard A
The purpose of this study was to describe how many rural family physicians (FPs) and other types of providers currently provide maternity care services, and the requirements to obtain privileges. Chief executive officers of rural hospitals were purposively sampled in 15 geographically diverse states with significant rural areas in 2013 to 2014. Questions were asked about the provision of maternity care services, the physicians who perform them, and qualifications required to obtain maternity care privileges. Analysis used descriptive statistics, with comparisons between the states, community rurality, and hospital size. The overall response rate was 51.2% (437/854). Among all identified hospitals, 44.9% provided maternity care services, which varied considerably by state (range, 17-83%; P < .001). In hospitals providing maternity care, a mean of 271 babies were delivered per year, 27% by cesarean delivery. A mean of 7.0 FPs had privileges in these hospitals, of which 2.8 provided maternity care and 1.8 performed cesarean deliveries. The percentage of FPs who provide maternity care (mean, 48%; range, 10-69%; P < .001), the percentage of FPs who do cesarean deliveries (mean, 66%; range, 0-100%; P < .001), and the percentage of all physicians who provide maternity care who are FPs (mean, 63%; range, 10-88%; P < .001) varied widely by state. Most hospitals (83%) had no firm numbers of procedures required to obtain privileges. FPs continue to provide the majority of maternity care services in US rural hospitals, including cesarean deliveries. Some family medicine residencies should continue to train their residents to provide these services to keep replenishing this valuable workforce. © Copyright 2017 by the American Board of Family Medicine.
Geometric structure and information change in phase transitions
NASA Astrophysics Data System (ADS)
Kim, Eun-jin; Hollerbach, Rainer
2017-06-01
We propose a toy model for a cyclic order-disorder transition and introduce a geometric methodology to understand stochastic processes involved in transitions. Specifically, our model consists of a pair of forward and backward processes (FPs and BPs) for the emergence and disappearance of a structure in a stochastic environment. We calculate time-dependent probability density functions (PDFs) and the information length L , which is the total number of different states that a system undergoes during the transition. Time-dependent PDFs during transient relaxation exhibit strikingly different behavior in FPs and BPs. In particular, FPs driven by instability undergo the broadening of the PDF with a large increase in fluctuations before the transition to the ordered state accompanied by narrowing the PDF width. During this stage, we identify an interesting geodesic solution accompanied by the self-regulation between the growth and nonlinear damping where the time scale τ of information change is constant in time, independent of the strength of the stochastic noise. In comparison, BPs are mainly driven by the macroscopic motion due to the movement of the PDF peak. The total information length L between initial and final states is much larger in BPs than in FPs, increasing linearly with the deviation γ of a control parameter from the critical state in BPs while increasing logarithmically with γ in FPs. L scales as |lnD | and D-1 /2 in FPs and BPs, respectively, where D measures the strength of the stochastic forcing. These differing scalings with γ and D suggest a great utility of L in capturing different underlying processes, specifically, diffusion vs advection in phase transition by geometry. We discuss physical origins of these scalings and comment on implications of our results for bistable systems undergoing repeated order-disorder transitions (e.g., fitness).
Kloepper, Joseph W.; McInroy, John A.; Liu, Ke; Hu, Chia-Hui
2013-01-01
Background Fern Distortion Syndrome (FDS) is a serious disease of Leatherleaf fern (Rumohra adiantiformis). The main symptom of FDS is distortion of fronds, making them unmarketable. Additional symptoms include stunting, irregular sporulation, decreased rhizome diameter, and internal discoloration of rhizomes. We previously reported an association of symptoms with increased endophytic rhizome populations of fluorescent pseudomonads (FPs). The aim of the current study was to determine if FPs from ferns in Costa Rica with typical FDS symptoms would recreate symptoms of FDS. Methodology and Findings Greenhouse tests were conducted over a 29-month period. Micro-propagated ferns derived from tissue culture were first grown one year to produce rhizomes. Then, using an 8×9 randomized complete block experimental design, 8 replicate rhizomes were inoculated by dipping into 9 different treatments before planting. Treatments included water without bacteria (control), and four different groups of FPs, each at a two concentrations. The four groups of FPs included one group from healthy ferns without symptoms (another control treatment), two groups isolated from inside rhizomes of symptomatic ferns, and one group isolated from inside roots of symptomatic ferns. Symptoms were assessed 12 and 17 months later, and populations of FPs inside newly formed rhizomes were determined after 17 months. Results showed that inoculation with mixtures of FPs from ferns with FDS symptoms, but not from healthy ferns, recreated the primary symptom of frond deformities and also the secondary symptoms of irregular sporulation, decreased rhizome diameter, and internal discoloration of rhizomes. Conclusions These results suggest a model of causation of FDS in which symptoms result from latent infections by multiple species of opportunistic endophytic bacteria containing virulence genes that are expressed when populations inside the plant reach a minimum level. PMID:23516499
Hegazi, Moustafa A; Sehlo, Mohammad G; Al-Jasir, Albandari; El-Deek, Basem S
2015-09-01
This study was conducted to assess development and cognitive functions in relation to growth in Saudi pre-school children with feeding problems (FPs) without underlying medical disorders. Three hundred fifteen pre-school children with FPs (221 with normal growth (FP-N), 62 with failure to thrive (FTT) (FP-FTT), 32 with overweight (FP-OW)) and 100 healthy children (Ref group) underwent in-depth assessment by anthropometric measurements, dietetic history, Behavioral Pediatrics Feeding Assessment Scale, Denver Developmental Screening test (DDST) and Stanford Binet fifth edition intelligence scales (SB-5). The main FPs detected in Saudi children were picky eating in 85.5% of FP-N group, infantile anorexia and poor eating in more than 90% of FP-FTT group and overeating in 53% of FP-OW group. FPs were not due to evident psychosocial factors but were mostly related to unhealthy feeding behaviours. FP-N children were still having normal growth parameters, but they had significantly lower growth parameters than healthy children. Failed screening with DDST was only more significantly recorded in FP-FTT children than in Ref children (P = 0.04). The overall IQ value by SB-5 was significantly lower in FP-FTT group compared with FP-N group (P = 0.01), in FP-FTT group compared with Ref group (P < 0.001) as well as in FP-OW group compared with Ref group (P < 0.001). Persistent FPs resulted in significant negative impact not only on growth status but also on developmental milestones and cognitive functions of pre-school children. Healthy feeding habits are mandatory to prevent serious consequences of FPs on growth and development of Saudi pre-school children. © 2015 The Authors. Journal of Paediatrics and Child Health © 2015 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Potential effects of the fire protection system sprays at Browns Ferry on fission product transport
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niemczyk, S.J.
1983-01-01
The fire protection system (FPS) sprays within any nuclear plant are not intended to mitigate radioactive releases to the environment resulting from severe core-damage accidents. However, it has been shown here that during certain postulated severe accident scenarios at the Browns Ferry Nuclear Plant, the functioning of FPS sprays could have a significant impact on the radioactive releases. Thus the effects of those sprays need to be taken into account for realistic estimation of source terms for some accident scenarios. The effects would include direct ones such as cooling of the reactor building atmosphere and scrubbing of radioactivity from it,more » as well as indirect effects such as an altered likelihood of hydrogen burning and flooding of various safety-related pumps in the reactor building basement. Thus some of the impacts of the sprays would be beneficial with respect to mitigating releases to the environment but some others might not be. The effects of the FPS would be very scenario dependent with a wide range of potential effects often existing for a given accident sequence. Any generalization of the specific results presented here for Browns Ferry to other nuclear plants must be done cautiously, as it appears from a preliminary investigation that the relevant physical and operational characteristics of FPS spray systems differ widely among even otherwise apparently similar plants. Likewise the standby gas treatment systems, which substantially impact the effects of the FPS, differ significantly among plants. More work for both Mark I plants and other plants, BWRs and PWRs alike, is indicated so the potential effects of FPS spray systems during severe accidents can be at least ball-parked for more realistic accident analyses.« less
Geometric structure and information change in phase transitions.
Kim, Eun-Jin; Hollerbach, Rainer
2017-06-01
We propose a toy model for a cyclic order-disorder transition and introduce a geometric methodology to understand stochastic processes involved in transitions. Specifically, our model consists of a pair of forward and backward processes (FPs and BPs) for the emergence and disappearance of a structure in a stochastic environment. We calculate time-dependent probability density functions (PDFs) and the information length L, which is the total number of different states that a system undergoes during the transition. Time-dependent PDFs during transient relaxation exhibit strikingly different behavior in FPs and BPs. In particular, FPs driven by instability undergo the broadening of the PDF with a large increase in fluctuations before the transition to the ordered state accompanied by narrowing the PDF width. During this stage, we identify an interesting geodesic solution accompanied by the self-regulation between the growth and nonlinear damping where the time scale τ of information change is constant in time, independent of the strength of the stochastic noise. In comparison, BPs are mainly driven by the macroscopic motion due to the movement of the PDF peak. The total information length L between initial and final states is much larger in BPs than in FPs, increasing linearly with the deviation γ of a control parameter from the critical state in BPs while increasing logarithmically with γ in FPs. L scales as |lnD| and D^{-1/2} in FPs and BPs, respectively, where D measures the strength of the stochastic forcing. These differing scalings with γ and D suggest a great utility of L in capturing different underlying processes, specifically, diffusion vs advection in phase transition by geometry. We discuss physical origins of these scalings and comment on implications of our results for bistable systems undergoing repeated order-disorder transitions (e.g., fitness).
Bright monomeric near-infrared fluorescent proteins as tags and biosensors for multiscale imaging
Shcherbakova, Daria M.; Baloban, Mikhail; Emelyanov, Alexander V.; Brenowitz, Michael; Guo, Peng; Verkhusha, Vladislav V.
2016-01-01
Monomeric near-infrared (NIR) fluorescent proteins (FPs) are in high demand as protein tags and components of biosensors for deep-tissue imaging and multicolour microscopy. We report three bright and spectrally distinct monomeric NIR FPs, termed miRFPs, engineered from bacterial phytochrome, which can be used as easily as GFP-like FPs. miRFPs are 2–5-fold brighter in mammalian cells than other monomeric NIR FPs and perform well in protein fusions, allowing multicolour structured illumination microscopy. miRFPs enable development of several types of NIR biosensors, such as for protein–protein interactions, RNA detection, signalling cascades and cell fate. We demonstrate this by engineering the monomeric fluorescence complementation reporters, the IκBα reporter for NF-κB pathway and the cell cycle biosensor for detection of proliferation status of cells in culture and in animals. miRFPs allow non-invasive visualization and detection of biological processes at different scales, from super-resolution microscopy to in vivo imaging, using the same probes. PMID:27539380
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultz, C; Dixon, S
Purpose: To evaluate whether one small systematic reduction in fluoroscopy frame rate has a significant effect on the total air kerma and/or dose area product for diagnostic and interventional cardiac catheterization procedures. Methods: The default fluoroscopy frame rate (FFR) was lowered from 15 to 10 fps in 5 Siemens™ Axiom Artis cardiac catheterization labs (CCL) on July 1, 2013. A total of 7212 consecutive diagnostic and interventional CCL procedures were divided into two study groups: 3602 procedures from 10/1/12 –6/30/13 with FFR of 15 fps; and 3610 procedures 7/1/13 – 3/31/14 at 10 fps. For each procedure, total air kermamore » (TAK), fluoroscopy skin dose (FSD), total/fluoroscopy dose area products (TAD, FAD), and total fluoroscopy time (FT) were recorded. Patient specific data collected for each procedure included: BSA, sex, height, weight, interventional versus diagnostic; and elective versus emergent. Results: For pre to post change in FFR, each categorical variable was compared using Pearson’s Chi-square test, Odds ratios and 95% confidence intervals. No statistically significant difference in BSA, height, weight, number of interventional versus diagnostic, elective versus emergent procedures was found between the two study groups. Decreasing the default FFR from 15 fps to 10 fps in the two study groups significantly reduced TAK from 1305 to 1061 mGy (p<0.0001), FSD from 627 to 454 mGy (p<0.0001), TAD from 8681 to 6991 uGy × m{sup 2}(p<0.0001), and FAD from 4493 to 3297 uGy × m{sup 2}(p<0.0001). No statistically significant difference in FT was noted. Clinical image quality was not analyzed, and reports of noticeable effects were minimal. From July 1, 2013 to date, the default FFR has remained 10 fps. Conclusion: Reducing the FFR from 15 to 10 fps significantly reduced total air kerma and dose area product which may decrease risk for potential radiation-induced skin injuries and improve patient outcomes.« less
Rapid Cycling and Its Treatment
... may be rapid, ultra-rapid or ultradian cycling. Biological rhythm disturbances: This theory proposes that people with rapid cycling have daily biological rhythms that are out of sync with typical “ ...
NASA Technical Reports Server (NTRS)
Price, Richard N.
2007-01-01
This paper intends to describe the lessons learned while specifying validating and installing a bit sync to replace the 30 year old Aydin Model 335a PCM bit sync used in the Space Shuttle Launch Control Center. The engineer had to analyze the original requirements and specifications and then create new requirements documentation that more correctly described our needs. One issue to consider was the removal of unnecessary requirements such as various data formats when only one format is used. The conversion to a system that no longer has an assortment of analog rotary switches required retraining of the operators. Finally, post-procurement corrections for undisclosed user requirements and missed design requirements required close contact with a manufacturer who was willing to accommodate the changes.
Clark, Rebecca E; Linville, Deanna; Rosen, Karen H
2009-04-01
Recognizing the fit between family medicine and marriage and family therapy (MFT), members of both fields have made significant advances in collaborative health research and practice. To add to this work, we surveyed a nationwide random sample of 240 family physicians (FPs) and asked about their perspectives and experiences of collaboration with MFTs. We found that FPs frequently perceive a need for their patients to receive MFT-related care, but their referral to and collaboration with MFTs were limited. Through responses to an open-ended question, we gained valuable information as to how MFTs could more effectively initiate collaboration with FPs.
[Comparative GC analysis of essential oil in imported sandalwood].
Wang, Z; Hong, X
1991-01-01
The GC-fingerprint spectra of essential oils in imported sandalwood are established by the new technique of GC-relative retention value fingerprint spectrum (GC-FPS). According to the GC-FPS of samples, their chromatographic peaks, overlap ratio of peaks and eight strong peaks are studied comparatively.
Towards real-time remote processing of laparoscopic video
NASA Astrophysics Data System (ADS)
Ronaghi, Zahra; Duffy, Edward B.; Kwartowitz, David M.
2015-03-01
Laparoscopic surgery is a minimally invasive surgical technique where surgeons insert a small video camera into the patient's body to visualize internal organs and small tools to perform surgical procedures. However, the benefit of small incisions has a drawback of limited visualization of subsurface tissues, which can lead to navigational challenges in the delivering of therapy. Image-guided surgery (IGS) uses images to map subsurface structures and can reduce the limitations of laparoscopic surgery. One particular laparoscopic camera system of interest is the vision system of the daVinci-Si robotic surgical system (Intuitive Surgical, Sunnyvale, CA, USA). The video streams generate approximately 360 megabytes of data per second, demonstrating a trend towards increased data sizes in medicine, primarily due to higher-resolution video cameras and imaging equipment. Processing this data on a bedside PC has become challenging and a high-performance computing (HPC) environment may not always be available at the point of care. To process this data on remote HPC clusters at the typical 30 frames per second (fps) rate, it is required that each 11.9 MB video frame be processed by a server and returned within 1/30th of a second. The ability to acquire, process and visualize data in real-time is essential for performance of complex tasks as well as minimizing risk to the patient. As a result, utilizing high-speed networks to access computing clusters will lead to real-time medical image processing and improve surgical experiences by providing real-time augmented laparoscopic data. We aim to develop a medical video processing system using an OpenFlow software defined network that is capable of connecting to multiple remote medical facilities and HPC servers.
A custom hardware classifier for bruised apple detection in hyperspectral images
NASA Astrophysics Data System (ADS)
Cárdenas, Javier; Figueroa, Miguel; Pezoa, Jorge E.
2015-09-01
We present a custom digital architecture for bruised apple classification using hyperspectral images in the near infrared (NIR) spectrum. The algorithm classifies each pixel in an image into one of three classes: bruised, non-bruised, and background. We extract two 5-element feature vectors for each pixel using only 10 out of the 236 spectral bands provided by the hyperspectral camera, thereby greatly reducing both the requirements of the imager and the computational complexity of the algorithm. We then use two linear-kernel support vector machine (SVM) to classify each pixel. Each SVM was trained with 504 windows of size 17×17-pixel taken from 14 hyperspectral images of 320×320 pixels each, for each class. The architecture then computes the percentage of bruised pixels in each apple in order to adequately classify the fruit. We implemented the architecture on a Xilinx Zynq Z-7010 field-programmable gate array (FPGA) and tested it on images from a NIR N17E push-broom camera with a frame rate of 25 fps, a band-pixel rate of 1.888 MHz, and 236 spectral bands between 900 and 1700 nanometers in laboratory conditions. Using 28-bit fixed-point arithmetic, the circuit accurately discriminates 95.2% of the pixels corresponding to an apple, 81% of the pixels corresponding to a bruised apple, and 96.4% of the background. With the default threshold settings, the highest false positive (FP) for a bruised apple is 18.7%. The circuit operates at the native frame rate of the camera, consumes 67 mW of dynamic power, and uses less than 10% of the logic resources on the FPGA.
Foo, Yong Hwee; Naredi-Rainer, Nikolaus; Lamb, Don C.; Ahmed, Sohail; Wohland, Thorsten
2012-01-01
Fluorescence cross-correlation spectroscopy (FCCS) is used to determine interactions and dissociation constants (Kds) of biomolecules. The determination of a Kd depends on the accurate measurement of the auto- and cross-correlation function (ACF and CCF) amplitudes. In the case of complete binding, the ratio of the CCF/ACF amplitudes is expected to be 1. However, measurements performed on tandem fluorescent proteins (FPs), in which two different FPs are linked, yield CCF/ACF amplitude ratios of ∼0.5 or less for different FCCS schemes. We use single wavelength FCCS and pulsed interleaved excitation FCCS to measure various tandem FPs constituted of different red and green FPs and determine the causes for this suboptimal ratio. The main causes for the reduced CCF/ACF amplitude ratio are differences in observation volumes for the different labels, the existence of dark FPs due to maturation problems, photobleaching, and to a lesser extent Förster (or fluorescence) resonance energy transfer between the labels. We deduce the fraction of nonfluorescent proteins for EGFP, mRFP, and mCherry as well as the differences in observation volumes. We use this information to correct FCCS measurements of the interaction of Cdc42, a small Rho-GTPase, with its effector IQGAP1 in live cell measurements to obtain a label-independent value for the Kd. PMID:22404940
Kadonosono, Tetsuya; Yabe, Etsuri; Furuta, Tadaomi; Yamano, Akihiro; Tsubaki, Takuya; Sekine, Takuya; Kuchimaru, Takahiro; Sakurai, Minoru; Kizaka-Kondoh, Shinae
2014-01-01
Peptides that have high affinity for target molecules on the surface of cancer cells are crucial for the development of targeted cancer therapies. However, unstructured peptides often fail to bind their target molecules with high affinity. To efficiently identify high-affinity target-binding peptides, we have constructed a fluorescent protein scaffold, designated gFPS, in which structurally constrained peptides are integrated at residues K131–L137 of superfolder green fluorescent protein. Molecular dynamics simulation supported the suitability of this site for presentation of exogenous peptides with a constrained structure. gFPS can present 4 to 12 exogenous amino acids without a loss of fluorescence. When gFPSs presenting human epidermal growth factor receptor type 2 (HER2)-targeting peptides were added to the culture medium of HER2-expressing cells, we could easily identify the peptides with high HER2-affinity and -specificity based on gFPS fluorescence. In addition, gFPS could be expressed on the yeast cell surface and applied for a high-throughput screening. These results demonstrate that gFPS has the potential to serve as a powerful tool to improve screening of structurally constrained peptides that have a high target affinity, and suggest that it could expedite the one-step identification of clinically applicable cancer cell-binding peptides. PMID:25084350
Mutants in the Candida glabrata Glycerol Channels Are Sensitized to Cell Wall Stress
Beese-Sims, Sara E.; Pan, Shih-Jung; Lee, Jongmin; Hwang-Wong, Elizabeth; Cormack, Brendan P.
2012-01-01
Many fungal species use glycerol as a compatible solute with which to maintain osmotic homeostasis in response to changes in external osmolarity. In Saccharomyces cerevisiae, intracellular glycerol concentrations are regulated largely by the high osmolarity glycerol (HOG) response pathway, both through induction of glycerol biosynthesis and control of its flux through the plasma membrane Fps1 glycerol channel. The channel activity of Fps1 is also controlled by a pair of positive regulators, Rgc1 and Rgc2. In this study, we demonstrate that Candida glabrata, a fungal pathogen that possesses two Fps1 orthologs and two Rgc1/-2 orthologs, accumulates glycerol in response to hyperosmotic stress. We present an initial characterization of mutants with deletions in the C. glabrata FPS1 (CAGL0C03267 [www.candidagenome.org]) and FPS2 (CAGL0E03894) genes and find that a double mutant accumulates glycerol, experiences constitutive cell wall stress, and is hypersensitive to treatment by caspofungin, an antifungal agent that targets the cell wall. This mutant is cleared more efficiently in mouse infections than is wild-type C. glabrata by caspofungin treatment. Finally, we demonstrate that one of the C. glabrata RGC orthologs complements an S. cerevisiae rgc1 rgc2 null mutant, supporting the conclusion that this regulatory assembly is conserved between these species. PMID:23087370
Ma, Yini; Huang, Anna; Cao, Siqi; Sun, Feifei; Wang, Lianhong; Guo, Hongyan; Ji, Rong
2016-12-01
Contamination of fine plastic particles (FPs), including micrometer to millimeter plastics (MPs) and nanometer plastics (NPs), in the environment has caught great concerns. FPs are strong adsorbents for hydrophobic toxic pollutants and may affect their fate and toxicity in the environment; however, such information is still rare. We studied joint toxicity of FPs with phenanthrene to Daphnia magna and effects of FPs on the environmental fate and bioaccumulation of 14 C-phenanthrene in fresh water. Within the five sizes particles we tested (from 50 nm to 10 μm), 50-nm NPs showed significant toxicity and physical damage to D. magna. The joint toxicity of 50-nm NPs and phenanthrene to D. magna showed an additive effect. During a 14-days incubation, the presence of NPs significantly enhanced bioaccumulation of phenanthrene-derived residues in daphnid body and inhibited the dissipation and transformation of phenanthrene in the medium, while 10-μm MPs did not show significant effects on the bioaccumulation, dissipation, and transformation of phenanthrene. The differences may be attributed to higher adsorption of phenanthrene on 50-nm NPs than 10-μm MPs. Our findings underlined the high potential ecological risks of FPs, and suggested that NPs should be given more concerns, in terms of their interaction with hydrophobic pollutants in the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Légaré, France; St-Jacques, Sylvie; Gagnon, Susie; Njoya, Merlin; Brisson, Michel; Frémont, Pierre; Rousseau, François
2011-04-01
To assess the willingness of women and their family physicians (FPs) to engage in shared decision-making (SDM) as regards prenatal Down-syndrome screening and the factors that might influence their willingness to do so. We conducted a survey of participants in Québec City, Canada, using the theory of planned behavior. We used a general linear model and multilevel approach that took the fact that some women consulted the same FP into account. This study comprised 109 pregnant women and 41 FPs. On a scale of - 3 to + 3, the pregnant women's and FPs' response scores were, respectively, 2.11 ± 1.38 and 2.66 ± 0.40. In women, attitude, significant others, self-efficacy, perceived moral correctness, and their FP's attitude influenced their willingness to engage in SDM. However, women without a post-secondary education were less likely to engage in SDM than women with a post-secondary education, mostly because the former lacked a sense of self-efficacy. In FPs, only attitude and significant others influenced their willingness to engage in SDM. Overall, the women and their FPs wished to engage in SDM as regards prenatal Down-syndrome screening. Only a few factors influenced this desire which therefore may be modifiable. Copyright © 2011 John Wiley & Sons, Ltd.
An Insect Eye Inspired Miniaturized Multi-Camera System for Endoscopic Imaging.
Cogal, Omer; Leblebici, Yusuf
2017-02-01
In this work, we present a miniaturized high definition vision system inspired by insect eyes, with a distributed illumination method, which can work in dark environments for proximity imaging applications such as endoscopy. Our approach is based on modeling biological systems with off-the-shelf miniaturized cameras combined with digital circuit design for real time image processing. We built a 5 mm radius hemispherical compound eye, imaging a 180 ° ×180 ° degrees field of view while providing more than 1.1 megapixels (emulated ommatidias) as real-time video with an inter-ommatidial angle ∆ϕ = 0.5 ° at 18 mm radial distance. We made an FPGA implementation of the image processing system which is capable of generating 25 fps video with 1080 × 1080 pixel resolution at a 120 MHz processing clock frequency. When compared to similar size insect eye mimicking systems in literature, the system proposed in this paper features 1000 × resolution increase. To the best of our knowledge, this is the first time that a compound eye with built-in illumination idea is reported. We are offering our miniaturized imaging system for endoscopic applications like colonoscopy or laparoscopic surgery where there is a need for large field of view high definition imagery. For that purpose we tested our system inside a human colon model. We also present the resulting images and videos from the human colon model in this paper.
Lightning Step Leader and Return Stroke Spectra at 100,000 fps
NASA Astrophysics Data System (ADS)
Harley, J.; McHarg, M.; Stenbaek-Nielsen, H. C.; Haaland, R. K.; Sonnenfeld, R.; Edens, H. E.; Cummer, S.; Lapierre, J. L.; Maddocks, S.
2017-12-01
A fundamental understanding of lightning can be inferred from the spectral emissions resulting from the leader and return stroke channels. We examine events recorded at 00:58:07 on 19 July 2015 and 06:44:24 on 23 July 2017, both at Langmuir Laboratory. Analysis of both events is supplemented by data from the Lightning Mapping Array at Langmuir. The 00:58:07 event spectra was recorded using a 100 line per mm grating in front of a Phantom V2010 camera with an 85mm (9o FOV) Nikon lens recording at 100,000 frames per second. Coarse resolution spectra (approximately 5 nm resolution) are produced from approximately 400 nm to 800 nm for each frame. We analyze several nitrogen and oxygen lines to understand step leader temperature behavior between cloud and ground. The 06:44:24 event spectra was recorded using a 300 line per mm grating (approximately 1.5 nm resolution) in front of a Phantom V2010 camera with an 50mm (32o FOV) Nikon lens also recording at 100,000 frames per second. Two ionized atomic nitrogen lines at 502 nm and 569 nm appear upon attachment and disappear as the return stroke travels from ground to cloud in approximately 5 frames. We analyze these lines to understand initial return stroke temperature and species behavior.
A reduced-dimensionality approach to uncovering dyadic modes of body motion in conversations.
Gaziv, Guy; Noy, Lior; Liron, Yuvalal; Alon, Uri
2017-01-01
Face-to-face conversations are central to human communication and a fascinating example of joint action. Beyond verbal content, one of the primary ways in which information is conveyed in conversations is body language. Body motion in natural conversations has been difficult to study precisely due to the large number of coordinates at play. There is need for fresh approaches to analyze and understand the data, in order to ask whether dyads show basic building blocks of coupled motion. Here we present a method for analyzing body motion during joint action using depth-sensing cameras, and use it to analyze a sample of scientific conversations. Our method consists of three steps: defining modes of body motion of individual participants, defining dyadic modes made of combinations of these individual modes, and lastly defining motion motifs as dyadic modes that occur significantly more often than expected given the single-person motion statistics. As a proof-of-concept, we analyze the motion of 12 dyads of scientists measured using two Microsoft Kinect cameras. In our sample, we find that out of many possible modes, only two were motion motifs: synchronized parallel torso motion in which the participants swayed from side to side in sync, and still segments where neither person moved. We find evidence of dyad individuality in the use of motion modes. For a randomly selected subset of 5 dyads, this individuality was maintained for at least 6 months. The present approach to simplify complex motion data and to define motion motifs may be used to understand other joint tasks and interactions. The analysis tools developed here and the motion dataset are publicly available.
A reduced-dimensionality approach to uncovering dyadic modes of body motion in conversations
Noy, Lior; Liron, Yuvalal; Alon, Uri
2017-01-01
Face-to-face conversations are central to human communication and a fascinating example of joint action. Beyond verbal content, one of the primary ways in which information is conveyed in conversations is body language. Body motion in natural conversations has been difficult to study precisely due to the large number of coordinates at play. There is need for fresh approaches to analyze and understand the data, in order to ask whether dyads show basic building blocks of coupled motion. Here we present a method for analyzing body motion during joint action using depth-sensing cameras, and use it to analyze a sample of scientific conversations. Our method consists of three steps: defining modes of body motion of individual participants, defining dyadic modes made of combinations of these individual modes, and lastly defining motion motifs as dyadic modes that occur significantly more often than expected given the single-person motion statistics. As a proof-of-concept, we analyze the motion of 12 dyads of scientists measured using two Microsoft Kinect cameras. In our sample, we find that out of many possible modes, only two were motion motifs: synchronized parallel torso motion in which the participants swayed from side to side in sync, and still segments where neither person moved. We find evidence of dyad individuality in the use of motion modes. For a randomly selected subset of 5 dyads, this individuality was maintained for at least 6 months. The present approach to simplify complex motion data and to define motion motifs may be used to understand other joint tasks and interactions. The analysis tools developed here and the motion dataset are publicly available. PMID:28141861
Development of the FPI+ as facility science instrument for SOFIA cycle four observations
NASA Astrophysics Data System (ADS)
Pfüller, Enrico; Wiedemann, Manuel; Wolf, Jürgen; Krabbe, Alfred
2016-08-01
The Stratospheric Observatory for Infrared Astronomy (SOFIA) is a heavily modified Boeing 747SP aircraft, accommodating a 2.5m infrared telescope. This airborne observation platform takes astronomers to flight altitudes of up to 13.7 km (45,000ft) and therefore allows an unobstructed view of the infrared universe at wavelengths between 0.3 m and 1600 m. SOFIA is currently completing its fourth cycle of observations and utilizes eight different imaging and spectroscopic science instruments. New instruments for SOFIAs cycle 4 observations are the High-resolution Airborne Wideband Camera-plus (HAWC+) and the Focal Plane Imager (FPI+). The latter is an integral part of the telescope assembly and is used on every SOFIA flight to ensure precise tracking on the desired targets. The FPI+ is used as a visual-light photometer in its role as facility science instrument. Since the upgrade of the FPI camera and electronics in 2013, it uses a thermo-electrically cooled science grade EM-CCD sensor inside a commercial-off-the-shelf Andor camera. The back-illuminated sensor has a peak quantum efficiency of 95% and the dark current is as low as 0.01 e-/pix/sec. With this new hardware the telescope has successfully tracked on 16th magnitude stars and thus the sky coverage, e.g. the area of sky that has suitable tracking stars, has increased to 99%. Before its use as an integrated tracking imager, the same type of camera has been used as a standalone diagnostic tool to analyze the telescope pointing stability at frequencies up to 200 Hz (imaging with 400 fps). These measurements help to improve the telescope pointing control algorithms and therefore reduce the image jitter in the focal plane. Science instruments benefit from this improvement with smaller image sizes for longer exposure times. The FPI has also been used to support astronomical observations like stellar occultations by the dwarf planet Pluto and a number of exoplanet transits. Especially the observation of the occultation events benefits from the high camera sensitivity, fast readout capability and the low read noise and it was possible to achieve high time resolution on the photometric light curves. This paper will give an overview of the development from the standalone diagnostic camera to the upgraded guiding/tracking camera, fully integrated into the telescope, while still offering the diagnostic capabilities and finally to the use as a facility science instrument on SOFIA.
Revolutionary visible and infrared sensor detectors for the most advanced astronomical AO systems
NASA Astrophysics Data System (ADS)
Feautrier, Philippe; Gach, Jean-Luc; Guieu, Sylvain; Downing, Mark; Jorden, Paul; Rothman, Johan; de Borniol, Eric D.; Balard, Philippe; Stadler, Eric; Guillaume, Christian; Boutolleau, David; Coussement, Jérome; Kolb, Johann; Hubin, Norbert; Derelle, Sophie; Robert, Clélia; Tanchon, Julien; Trollier, Thierry; Ravex, Alain; Zins, Gérard; Kern, Pierre; Moulin, Thibaut; Rochat, Sylvain; Delpoulbé, Alain; Lebouqun, Jean-Baptiste
2014-07-01
We report in this paper decisive advance on the detector development for the astronomical applications that require very fast operation. Since the CCD220 and OCAM2 major success, new detector developments started in Europe either for visible and IR wavelengths. Funded by ESO and the FP7 Opticon European network, the NGSD CMOS device is fully dedicated to Natural and Laser Guide Star AO for the E-ELT with strong ESO involvement. The NGSD will be a 880x840 pixels CMOS detector with a readout noise of 3 e (goal 1e) at 700 Hz frame rate and providing digital outputs. A camera development, based on this CMOS device and also funded by the Opticon European network, is ongoing. Another major AO wavefront sensing detector development concerns IR detectors based on Avalanche Photodiode (e- APD) arrays within the RAPID project. Developed by the SOFRADIR and CEA/LETI manufacturers, the latter offers a 320x255 8 outputs 30 microns IR array, sensitive from 0.4 to 3 microns, with less than 2 e readout noise at 1600 fps. A rectangular window can also be programmed to speed up even more the frame rate when the full frame readout is not required. The high QE response, in the range of 70%, is almost flat over this wavelength range. Advanced packaging with miniature cryostat using pulse tube cryocoolers was developed in the frame of this programme in order to allow use on this detector in any type of environment. The characterization results of this device are presented here. Readout noise as low as 1.7 e at 1600 fps has been measured with a 3 microns wavelength cut-off chip and a multiplication gain of 14 obtained with a limited photodiode polarization of 8V. This device also exhibits excellent linearity, lower than 1%. The pulse tube cooling allows smart and easy cooling down to 55 K. Vibrations investigations using centroiding and FFT measurements were performed proving that the miniature pulse tube does not induce measurable vibrations to the optical bench, allowing use of this cooled device without liquid nitrogen in very demanding environmental conditions. A successful test of this device was performed on sky on the PIONIER 4 telescopes beam combiner on the VLTi at ESOParanal in June 2014. First Light Imaging, which will commercialize a camera system using also APD infrared arrays in its proprietary wavefront sensor camera platform. These programs are held with several partners, among them are the French astronomical laboratories (LAM, OHP, IPAG), the detector manufacturers (e2v technologies, Sofradir, CEA/LETI) and other partners (ESO, ONERA, IAC, GTC, First Light Imaging). Funding is: Opticon FP7 from European Commission, ESO, CNRS and Université de Provence, Sofradir, ONERA, CEA/LETI the French FUI (DGCIS), the FOCUS Labex and OSEO.
Crowley, Sheila A; Foley, Sallie M; Wittmann, Daniela; Jagielski, Christina H; Dunn, Rodney L; Clark, Patricia M; Griggs, Jennifer J; Peterson, Catherine; Leonard, Marcia; An, Lawrence C; Wei, John T; Montie, James E; Janz, Nancy K
2016-09-01
While it is recognized that cancer treatment can contribute to problems in sexual function, much less is currently known about the specific sexual health concerns and information needs of cancer survivors. This study tested a new instrument to measure cancer survivors' sexual health concerns and needs for sexual information after cancer treatment. The Information on Sexual Health: Your Needs after Cancer (InSYNC), developed by a multidisciplinary team of experts, is a novel 12-item questionnaire to measure sexual health concerns and information needs of cancer survivors. We tested the measure with a sample of breast and prostate cancer survivors. A convenience sample of 114 cancer survivors (58 breast, 56 prostate) was enrolled. Results of the InSYNC questionnaire showed high levels of sexual concern among cancer survivors. Areas of concern differed by cancer type. Prostate cancer survivors were most concerned about being able to satisfy their partners (57 %) while breast cancer survivors were most concerned with changes in how their bodies worked sexually (46 %). Approximately 35 % of all cancer survivors wanted more information about sexual health. Sexual health concerns and unmet information needs are common among breast and prostate cancer survivors, varying in some aspects by type of cancer. Routine screening for sexual health concerns should be included in comprehensive cancer survivorship care to appropriately address health care needs. The InSYNC questionnaire is one tool that may help clinicians identify concerns facing their patients.
Fujimoto, Satoru; Sugano, Shigeo S.; Kuwata, Keiko; Osakabe, Keishi; Matsunaga, Sachihiro
2016-01-01
Live imaging of the dynamics of nuclear organization provides the opportunity to uncover the mechanisms responsible for four-dimensional genome architecture. Here, we describe the use of fluorescent protein (FP) fusions of transcription activator-like effectors (TALEs) to visualize endogenous genomic sequences in Arabidopsis thaliana. The ability to engineer sequence-specific TALEs permits the investigation of precise genomic sequences. We could detect TALE-FP signals associated with centromeric, telomeric, and rDNA repeats and the signal distribution was consistent with that observed by fluorescent in situ hybridization. TALE-FPs are advantageous because they permit the observation of intact tissues. We used our TALE-FP method to investigate the nuclei of several multicellular plant tissues including roots, hypocotyls, leaves, and flowers. Because TALE-FPs permit live-cell imaging, we successfully observed the temporal dynamics of centromeres and telomeres in plant organs. Fusing TALEs to multimeric FPs enhanced the signal intensity when observing telomeres. We found that the mobility of telomeres was different in sub-nuclear regions. Transgenic plants stably expressing TALE-FPs will provide new insights into chromatin organization and dynamics in multicellular organisms. PMID:27811079
Design of low noise imaging system
NASA Astrophysics Data System (ADS)
Hu, Bo; Chen, Xiaolai
2017-10-01
In order to meet the needs of engineering applications for low noise imaging system under the mode of global shutter, a complete imaging system is designed based on the SCMOS (Scientific CMOS) image sensor CIS2521F. The paper introduces hardware circuit and software system design. Based on the analysis of key indexes and technologies about the imaging system, the paper makes chips selection and decides SCMOS + FPGA+ DDRII+ Camera Link as processing architecture. Then it introduces the entire system workflow and power supply and distribution unit design. As for the software system, which consists of the SCMOS control module, image acquisition module, data cache control module and transmission control module, the paper designs in Verilog language and drives it to work properly based on Xilinx FPGA. The imaging experimental results show that the imaging system exhibits a 2560*2160 pixel resolution, has a maximum frame frequency of 50 fps. The imaging quality of the system satisfies the requirement of the index.
Snapshot hyperspectral retinal imaging using compact spectral resolving detector array.
Li, Hao; Liu, Wenzhong; Dong, Biqin; Kaluzny, Joel V; Fawzi, Amani A; Zhang, Hao F
2017-06-01
Hyperspectral retinal imaging captures the light spectrum from each imaging pixel. It provides spectrally encoded retinal physiological and morphological information, which could potentially benefit diagnosis and therapeutic monitoring of retinal diseases. The key challenges in hyperspectral retinal imaging are how to achieve snapshot imaging to avoid motions between the images from multiple spectral bands, and how to design a compact snapshot imager suitable for clinical use. Here, we developed a compact, snapshot hyperspectral fundus camera for rodents using a novel spectral resolving detector array (SRDA), on which a thin-film Fabry-Perot cavity filter was monolithically fabricated on each imaging pixel. We achieved hyperspectral retinal imaging with 16 wavelength bands (460 to 630 nm) at 20 fps. We also demonstrated false-color vessel contrast enhancement and retinal oxygen saturation (sO 2 ) measurement through spectral analysis. This work could potentially bring hyperspectral retinal imaging from bench to bedside. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
High Accuracy Monocular SFM and Scale Correction for Autonomous Driving.
Song, Shiyu; Chandraker, Manmohan; Guest, Clark C
2016-04-01
We present a real-time monocular visual odometry system that achieves high accuracy in real-world autonomous driving applications. First, we demonstrate robust monocular SFM that exploits multithreading to handle driving scenes with large motions and rapidly changing imagery. To correct for scale drift, we use known height of the camera from the ground plane. Our second contribution is a novel data-driven mechanism for cue combination that allows highly accurate ground plane estimation by adapting observation covariances of multiple cues, such as sparse feature matching and dense inter-frame stereo, based on their relative confidences inferred from visual data on a per-frame basis. Finally, we demonstrate extensive benchmark performance and comparisons on the challenging KITTI dataset, achieving accuracy comparable to stereo and exceeding prior monocular systems. Our SFM system is optimized to output pose within 50 ms in the worst case, while average case operation is over 30 fps. Our framework also significantly boosts the accuracy of applications like object localization that rely on the ground plane.
Algorithm architecture co-design for ultra low-power image sensor
NASA Astrophysics Data System (ADS)
Laforest, T.; Dupret, A.; Verdant, A.; Lattard, D.; Villard, P.
2012-03-01
In a context of embedded video surveillance, stand alone leftbehind image sensors are used to detect events with high level of confidence, but also with a very low power consumption. Using a steady camera, motion detection algorithms based on background estimation to find regions in movement are simple to implement and computationally efficient. To reduce power consumption, the background is estimated using a down sampled image formed of macropixels. In order to extend the class of moving objects to be detected, we propose an original mixed mode architecture developed thanks to an algorithm architecture co-design methodology. This programmable architecture is composed of a vector of SIMD processors. A basic RISC architecture was optimized in order to implement motion detection algorithms with a dedicated set of 42 instructions. Definition of delta modulation as a calculation primitive has allowed to implement algorithms in a very compact way. Thereby, a 1920x1080@25fps CMOS image sensor performing integrated motion detection is proposed with a power estimation of 1.8 mW.
High speed digital holographic interferometry for hypersonic flow visualization
NASA Astrophysics Data System (ADS)
Hegde, G. M.; Jagdeesh, G.; Reddy, K. P. J.
2013-06-01
Optical imaging techniques have played a major role in understanding the flow dynamics of varieties of fluid flows, particularly in the study of hypersonic flows. Schlieren and shadowgraph techniques have been the flow diagnostic tools for the investigation of compressible flows since more than a century. However these techniques provide only the qualitative information about the flow field. Other optical techniques such as holographic interferometry and laser induced fluorescence (LIF) have been used extensively for extracting quantitative information about the high speed flows. In this paper we present the application of digital holographic interferometry (DHI) technique integrated with short duration hypersonic shock tunnel facility having 1 ms test time, for quantitative flow visualization. Dynamics of the flow fields in hypersonic/supersonic speeds around different test models is visualized with DHI using a high-speed digital camera (0.2 million fps). These visualization results are compared with schlieren visualization and CFD simulation results. Fringe analysis is carried out to estimate the density of the flow field.
High-speed railway real-time localization auxiliary method based on deep neural network
NASA Astrophysics Data System (ADS)
Chen, Dongjie; Zhang, Wensheng; Yang, Yang
2017-11-01
High-speed railway intelligent monitoring and management system is composed of schedule integration, geographic information, location services, and data mining technology for integration of time and space data. Assistant localization is a significant submodule of the intelligent monitoring system. In practical application, the general access is to capture the image sequences of the components by using a high-definition camera, digital image processing technique and target detection, tracking and even behavior analysis method. In this paper, we present an end-to-end character recognition method based on a deep CNN network called YOLO-toc for high-speed railway pillar plate number. Different from other deep CNNs, YOLO-toc is an end-to-end multi-target detection framework, furthermore, it exhibits a state-of-art performance on real-time detection with a nearly 50fps achieved on GPU (GTX960). Finally, we realize a real-time but high-accuracy pillar plate number recognition system and integrate natural scene OCR into a dedicated classification YOLO-toc model.
How do dragonflies recover from falling upside down?
NASA Astrophysics Data System (ADS)
Wang, Z. Jane; Melfi, James, Jr.; Leonardo, Anthony
2014-11-01
We release dragonflies from a magnetic tether so that they fall from an initially upside down orientation. To recover, the dragonflies roll their body 180 degrees every time. This set up offers an effective method for eliciting a stereotypical turn so that we can collect a large amount of data on the same turn. From the wing and body kinematics, we can tease out the strategy dragonflies use to roll their body. We record these flights with three zoomed in high-speed video cameras. By filming at 4000 to 8000fps, we measure the wing twist along each of the four wings as a part of the 3D wing kinematics. The shape of the wing twist depends on the interaction between the aerodynamic torque and the torque exerted by muscles, therefore providing clues on which of their four wings actively participate in creating the turn. By applying dynamic calculations to the measured kinematics, we further deduce the amount of torques dragonflies exert in order to turn.
Fu, Yi; Lau, Yiu-Ting R; Weng, Lu-Tao; Ng, Kai-Mo; Chan, Chi-Ming
2014-10-01
Poly (2, 3, 4, 5, 6-pentafluorostyrene) (5FPS) was prepared by bulk radical polymerization. The spin-cast films of this polymer were analyzed using time-of-flight secondary ion mass spectrometry (ToF-SIMS) at various temperatures ranging from room temperature to 120°C. Principal component analysis (PCA) of the ToF-SIMS data revealed a transition temperature (T(T)) at which the surface structure of 5FPS was rearranged. A comparison between the results of the PCA of ToF-SIMS spectra obtained on 5FPS and polystyrene (PS) indicate that the pendant groups of 5FPS and PS moved in exactly opposite directions as the temperature increased. More pendant groups of 5FPS and PS migrated from the bulk to the surface and verse versa, respectively, as the temperature increased. These results clearly support the view that the abrupt changes in the normalized principal component 1 value was caused by the surface reorientation of the polymers and not by a change in the ion fragmentation mechanism at temperatures above the T(T). Contact angle measurement, which is another extremely surface sensitive technique, was used to monitor the change in the surface tension as a function of temperature. A clear T(T) was determined by the contact angle measurements. The T(T) values determined by contact angle measurements and ToF-SIMS were very similar. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Brost, Alexander; Bourier, Felix; Wimmer, Andreas; Koch, Martin; Kiraly, Atilla; Liao, Rui; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert
2012-02-01
Atrial fibrillation (AFib) has been identified as a major cause of stroke. Radiofrequency catheter ablation has become an increasingly important treatment option, especially when drug therapy fails. Navigation under X-ray can be enhanced by using augmented fluoroscopy. It renders overlay images from pre-operative 3-D data sets which are then fused with X-ray images to provide more details about the underlying soft-tissue anatomy. Unfortunately, these fluoroscopic overlay images are compromised by respiratory and cardiac motion. Various methods to deal with motion have been proposed. To meet clinical demands, they have to be fast. Methods providing a processing frame rate of 3 frames-per-second (fps) are considered suitable for interventional electrophysiology catheter procedures if an acquisition frame rate of 2 fps is used. Unfortunately, when working at a processing rate of 3 fps, the delay until the actual motion compensated image can be displayed is about 300 ms. More recent algorithms can achieve frame rates of up to 20 fps, which reduces the lag to 50 ms. By using a novel approach involving a 3-D catheter model, catheter segmentation and a distance transform, we can speed up motion compensation to 25 fps which results in a display delay of only 40 ms on a standard workstation for medical applications. Our method uses a constrained 2-D/3-D registration to perform catheter tracking, and it obtained a 2-D tracking error of 0.61 mm.
Liu, Huan; Wang, Qi; Lu, Zuxun; Liu, Junan
2014-10-30
The World Health Assembly has pledged to achieve universal reproductive health (RH) coverage by 2015. Therefore, China has been vigorously promoting the equalisation of basic public health services (i.e. RH services). The floating population (FP) is the largest special group of internal migrants in China and constitutes the current national focus. However, gaps exist in the access of this group to RH services in China. A total of 453 members of the FP and 794 members of the residential population (RP) aged 18 to 50 years from five urban districts in Guangzhou City were recruited to participate in a cross-sectional survey in 2009. Information on demographics and socioeconomic status (SES) were collected from these two groups to evaluate the utilisation of RH knowledge and skills and family planning services (FPS), and to identify social determinants. The proportion of individuals with low SES in the FP (19.2%) was higher than that in the RP (6.3%) (P <0.001). Of the FP, 9.7% to 35.8% had no knowledge of at least one skill, a proportion higher than the counterpart values (6.2% to 27.5%) for the RP (P <0.05). The frequency of FPS use among the FP and RP was low. However, FPS use was higher among the FP than among the RP (3.51 vs. 2.99) (P =0.050). Logistic regression analysis was used to analyse the social determinants that influence FPS use in the FP and RP. The factors that affect FPS utilisation of the RP included SES (OR =4.652, 95% CI =1.751, 12.362), whereas those of the FP excluded SES. The FPS use of the FP in Guangzhou City was higher under equalised public health services. However, a need still exists to help the FP with low SES to improve their RH knowledge and skills through access to public RH services.
Care coordination for children with special health care needs: a cohort study.
Zanello, Elisa; Calugi, Simona; Sanders, Lee M; Lenzi, Jacopo; Faldella, Giacomo; Rucci, Paola; Fantini, Maria Pia
2017-02-03
Care coordination is widely recognized as a key element of care for patients with chronic and complex medical conditions and their families. In care for children with special health care needs the Family Pediatrician (FP) plays a central role as care coordinator. This study aims to evaluate the FPs' activities of care coordination for children with special health care needs in the pediatric primary care setting, using an on-line measurement tool. Within the prospective cohort study SpeNK (Special Needs Kids), newborns and children with special health care needs were recruited at discharge from three hospital facilities in Bologna province, from October 1st 2012 to September 30th 2014. Their FPs were invited to complete a questionnaire (SpeNK-FP) at each encounter for the patient during a 9-month period after hospital discharge. SpeNK-FP was developed by adapting the Care Coordination Measurement Tool (CCMT©) developed by Antonelli et al., to the Italian organizational context. The outcome of interest, derived from the questionnaire, is inappropriate use of services. Forty FPs completed assessments for 49 children at each of 382 clinical encounters. The majority of children (71.4%) had special health care needs, without complicating social issues. FPs reported "no need for care coordination" in 50.8% of the encounters and 41.1% of records about patient needs requiring care coordination. The most common activity implemented to meet children's needs was telephone contact with a medical provider. According to FPs, 80% of encounters prevented inappropriate services use. In multivariate regression, pediatric-specialist contact (telephone or in person) was associated with reduced odds of physician report of preventable hospitalization (OR = 0.06, 95% CI 0.01-0.42, p = 0.005). The study shows the potential for FPs in Italy to serve as care coordinators and facilitate the implementation of integrated care pathways for children with special health care needs.
Biomechanical characteristics of fixation methods for floating pubic symphysis.
Song, Wenhao; Zhou, Dongsheng; He, Yu
2017-03-07
Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.
Rubin, Susan E; Coy, Lauren N; Yu, Qingzhao; Muncie, Herbert L
2016-10-01
The adolescent pregnancy rate in Louisiana (LA) and Mississippi (MS) is one of the highest in the United States. One approach to decrease that rate is to increase contraceptive use. We sought to characterize LA and MS family physicians' (FPs) contraception counseling for adolescents with a focus on the intrauterine contraceptive device (IUD). DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: Online survey of resident and practicing physician members of the LA and MS Academy of FPs. Three hundred ninety-eight of 1616 invited FPs responded; 244 were included in our analysis. When counseling adolescents about contraception, respondents "frequently discussed" oral contraceptives and condoms 87.5% (210/240) and 83.8% (202/241) of the time, respectively. Newer and more highly effective contraceptives such as the ring, patch, IUD, and implant were "frequently discussed" only 34.6% (82/237)-39.3% (92/234) of the time. In the previous 6 months, 56% (136/243) of respondents ever discussed an IUD with an adolescent. Respondents were more likely to have discussed IUDs if they learned IUD insertion during residency, had on-site access to IUD inserters, believed they were competent and/or comfortable with IUD counseling. In 5 clinical scenarios asking whether the respondent would recommend an IUD to a 17- or a 27-year-old patient (in all scenarios patients were eligible for an IUD), respondents were restrictive overall and significantly fewer would recommend an IUD for the adolescent. Our results suggest that there are missed opportunities for full-scope contraception counseling by LA and MS FPs. When these FPs counsel adolescents about contraception they less frequently discuss newer methods and more highly effective methods. Additionally many LA and MS FPs use overly restrictive eligibility criteria when considering IUDs. Copyright © 2016 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Suzuki, Kenji
2009-09-21
Computer-aided diagnosis (CAD) has been an active area of study in medical image analysis. A filter for the enhancement of lesions plays an important role for improving the sensitivity and specificity in CAD schemes. The filter enhances objects similar to a model employed in the filter; e.g. a blob-enhancement filter based on the Hessian matrix enhances sphere-like objects. Actual lesions, however, often differ from a simple model; e.g. a lung nodule is generally modeled as a solid sphere, but there are nodules of various shapes and with internal inhomogeneities such as a nodule with spiculations and ground-glass opacity. Thus, conventional filters often fail to enhance actual lesions. Our purpose in this study was to develop a supervised filter for the enhancement of actual lesions (as opposed to a lesion model) by use of a massive-training artificial neural network (MTANN) in a CAD scheme for detection of lung nodules in CT. The MTANN filter was trained with actual nodules in CT images to enhance actual patterns of nodules. By use of the MTANN filter, the sensitivity and specificity of our CAD scheme were improved substantially. With a database of 69 lung cancers, nodule candidate detection by the MTANN filter achieved a 97% sensitivity with 6.7 false positives (FPs) per section, whereas nodule candidate detection by a difference-image technique achieved a 96% sensitivity with 19.3 FPs per section. Classification-MTANNs were applied for further reduction of the FPs. The classification-MTANNs removed 60% of the FPs with a loss of one true positive; thus, it achieved a 96% sensitivity with 2.7 FPs per section. Overall, with our CAD scheme based on the MTANN filter and classification-MTANNs, an 84% sensitivity with 0.5 FPs per section was achieved.
Primary Generators of Visually Evoked Field Potentials Recorded in the Macaque Auditory Cortex.
Kajikawa, Yoshinao; Smiley, John F; Schroeder, Charles E
2017-10-18
Prior studies have reported "local" field potential (LFP) responses to faces in the macaque auditory cortex and have suggested that such face-LFPs may be substrates of audiovisual integration. However, although field potentials (FPs) may reflect the synaptic currents of neurons near the recording electrode, due to the use of a distant reference electrode, they often reflect those of synaptic activity occurring in distant sites as well. Thus, FP recordings within a given brain region (e.g., auditory cortex) may be "contaminated" by activity generated elsewhere in the brain. To determine whether face responses are indeed generated within macaque auditory cortex, we recorded FPs and concomitant multiunit activity with linear array multielectrodes across auditory cortex in three macaques (one female), and applied current source density (CSD) analysis to the laminar FP profile. CSD analysis revealed no appreciable local generator contribution to the visual FP in auditory cortex, although we did note an increase in the amplitude of visual FP with cortical depth, suggesting that their generators are located below auditory cortex. In the underlying inferotemporal cortex, we found polarity inversions of the main visual FP components accompanied by robust CSD responses and large-amplitude multiunit activity. These results indicate that face-evoked FP responses in auditory cortex are not generated locally but are volume-conducted from other face-responsive regions. In broader terms, our results underscore the caution that, unless far-field contamination is removed, LFPs in general may reflect such "far-field" activity, in addition to, or in absence of, local synaptic responses. SIGNIFICANCE STATEMENT Field potentials (FPs) can index neuronal population activity that is not evident in action potentials. However, due to volume conduction, FPs may reflect activity in distant neurons superimposed upon that of neurons close to the recording electrode. This is problematic as the default assumption is that FPs originate from local activity, and thus are termed "local" (LFP). We examine this general problem in the context of previously reported face-evoked FPs in macaque auditory cortex. Our findings suggest that face-FPs are indeed generated in the underlying inferotemporal cortex and volume-conducted to the auditory cortex. The note of caution raised by these findings is of particular importance for studies that seek to assign FP/LFP recordings to specific cortical layers. Copyright © 2017 the authors 0270-6474/17/3710139-15$15.00/0.
Primary Generators of Visually Evoked Field Potentials Recorded in the Macaque Auditory Cortex
Smiley, John F.; Schroeder, Charles E.
2017-01-01
Prior studies have reported “local” field potential (LFP) responses to faces in the macaque auditory cortex and have suggested that such face-LFPs may be substrates of audiovisual integration. However, although field potentials (FPs) may reflect the synaptic currents of neurons near the recording electrode, due to the use of a distant reference electrode, they often reflect those of synaptic activity occurring in distant sites as well. Thus, FP recordings within a given brain region (e.g., auditory cortex) may be “contaminated” by activity generated elsewhere in the brain. To determine whether face responses are indeed generated within macaque auditory cortex, we recorded FPs and concomitant multiunit activity with linear array multielectrodes across auditory cortex in three macaques (one female), and applied current source density (CSD) analysis to the laminar FP profile. CSD analysis revealed no appreciable local generator contribution to the visual FP in auditory cortex, although we did note an increase in the amplitude of visual FP with cortical depth, suggesting that their generators are located below auditory cortex. In the underlying inferotemporal cortex, we found polarity inversions of the main visual FP components accompanied by robust CSD responses and large-amplitude multiunit activity. These results indicate that face-evoked FP responses in auditory cortex are not generated locally but are volume-conducted from other face-responsive regions. In broader terms, our results underscore the caution that, unless far-field contamination is removed, LFPs in general may reflect such “far-field” activity, in addition to, or in absence of, local synaptic responses. SIGNIFICANCE STATEMENT Field potentials (FPs) can index neuronal population activity that is not evident in action potentials. However, due to volume conduction, FPs may reflect activity in distant neurons superimposed upon that of neurons close to the recording electrode. This is problematic as the default assumption is that FPs originate from local activity, and thus are termed “local” (LFP). We examine this general problem in the context of previously reported face-evoked FPs in macaque auditory cortex. Our findings suggest that face-FPs are indeed generated in the underlying inferotemporal cortex and volume-conducted to the auditory cortex. The note of caution raised by these findings is of particular importance for studies that seek to assign FP/LFP recordings to specific cortical layers. PMID:28924008
What Motivates Family Physicians to Participate in Training Programs in Shared Decision Making?
ERIC Educational Resources Information Center
Allaire, Anne-Sophie; Labrecque, Michel; Giguere, Anik; Gagnon, Marie-Pierre; Legare, France
2012-01-01
Introduction: Little is known about the factors that influence family physician (FP) participation in continuing professional development (CPD) programs in shared decision making (SDM). We sought to identify the factors that motivate FPs to participate in DECISION+, a CPD program in SDM. Methods: In 2007-2008, we collected data from 39 FPs who…
Fluorescent Proteins: A Cell Biologist's User Guide
Snapp, Erik Lee
2009-01-01
Fluorescent Proteins (FPs) have revolutionized cell biology. The value of labeling and visualizing proteins in living cells is evident from thousands of publications since the cloning of Green Fluorescent Protein (GFP). Biologists have been flooded with a cornucopia of FPs; however, the FP toolbox has not necessarily been optimized for cell biologists. Common FP plasmids are suboptimal for FP-fusion protein construction. More problematic are commercial and investigator-constructed FP-fusion proteins that disrupt important cellular targeting information. Even when cell biologists correctly construct FP-fusion proteins, it is rarely self-evident which FP should be used. Important FP information, such as oligomer formation or photostability, is often unsearchable or anecdotal. This brief guide is offered to assist in correctly exploiting FPs in cells. PMID:19819147
Electronic construction collaboration system : phase III.
DOT National Transportation Integrated Search
2011-12-01
This phase of the electronic collaboration project involved two major efforts: 1) implementation of AEC Sync (formerly known as Attolist), a web-based project management system (WPMS), on the Broadway Viaduct Bridge Project and the Iowa Falls Arch Br...
A collaborative interaction and visualization multi-modal environment for surgical planning.
Foo, Jung Leng; Martinez-Escobar, Marisol; Peloquin, Catherine; Lobe, Thom; Winer, Eliot
2009-01-01
The proliferation of virtual reality visualization and interaction technologies has changed the way medical image data is analyzed and processed. This paper presents a multi-modal environment that combines a virtual reality application with a desktop application for collaborative surgical planning. Both visualization applications can function independently but can also be synced over a network connection for collaborative work. Any changes to either application is immediately synced and updated to the other. This is an efficient collaboration tool that allows multiple teams of doctors with only an internet connection to visualize and interact with the same patient data simultaneously. With this multi-modal environment framework, one team working in the VR environment and another team from a remote location working on a desktop machine can both collaborate in the examination and discussion for procedures such as diagnosis, surgical planning, teaching and tele-mentoring.
Ensemble Perception of Dynamic Emotional Groups.
Elias, Elric; Dyer, Michael; Sweeny, Timothy D
2017-02-01
Crowds of emotional faces are ubiquitous, so much so that the visual system utilizes a specialized mechanism known as ensemble coding to see them. In addition to being proximally close, members of emotional crowds, such as a laughing audience or an angry mob, often behave together. The manner in which crowd members behave-in sync or out of sync-may be critical for understanding their collective affect. Are ensemble mechanisms sensitive to these dynamic properties of groups? Here, observers estimated the average emotion of a crowd of dynamic faces. The members of some crowds changed their expressions synchronously, whereas individuals in other crowds acted asynchronously. Observers perceived the emotion of a synchronous group more precisely than the emotion of an asynchronous crowd or even a single dynamic face. These results demonstrate that ensemble representation is particularly sensitive to coordinated behavior, and they suggest that shared behavior is critical for understanding emotion in groups.
2012-01-01
Background Patients in sub-Saharan Africa commonly experience pain, which often is un-assessed and undertreated. One hindrance to routine pain assessment in these settings is the lack of a single-item pain rating scale validated for the particular context. The goal of this study was to examine the face validity and cultural acceptability of two single-item pain scales, the Numerical Rating Scale (NRS) and the Faces Pain Scale-Revised (FPS-R), in a population of patients on the medical, surgical, and pediatric wards of Moi Teaching and Referral Hospital in Kenya. Methods Swahili versions of the NRS and FPS-R were developed by standard translation and back-translation. Cognitive interviews were performed with 15 patients at Moi Teaching and Referral Hospital in Eldoret, Kenya. Interview transcripts were analyzed on a question-by-question basis to identify major themes revealed through the cognitive interviewing process and to uncover any significant problems participants encountered with understanding and using the pain scales. Results Cognitive interview analysis demonstrated that participants had good comprehension of both the NRS and the FPS-R and showed rational decision-making processes in choosing their responses. Participants felt that both scales were easy to use. The FPS-R was preferred almost unanimously to the NRS. Conclusions The face validity and acceptability of the Swahili versions of the NRS and FPS-R has been demonstrated for use in Kenyan patients. The broader application of these scales should be evaluated and may benefit patients who currently suffer from pain. PMID:22512923
Validity of the Framingham point scores in the elderly: results from the Rotterdam study.
Koller, Michael T; Steyerberg, Ewout W; Wolbers, Marcel; Stijnen, Theo; Bucher, Heiner C; Hunink, M G Myriam; Witteman, Jacqueline C M
2007-07-01
The National Cholesterol Education Program recommends assessing 10-year risk of coronary heart disease (CHD) in individuals free of established CHD with the Framingham Point Scores (FPS). Individuals with a risk >20% are classified as high risk and are candidates for preventive intervention. We aimed to validate the FPS in a European population of elderly subjects. Subjects free of established CHD at baseline were selected from the Rotterdam study, a population-based cohort of subjects 55 years or older in The Netherlands. We studied calibration, discrimination (c-index), and the accuracy of high-risk classifications. Events consisted of fatal CHD and nonfatal myocardial infarction. Among 6795 subjects, 463 died because of CHD and 336 had nonfatal myocardial infarction. Predicted 10-year risk of CHD was on average well calibrated for women (9.9% observed vs 10.1% predicted) but showed substantial overestimation in men (14.3% observed vs 19.8% predicted), particularly with increasing age. This resulted in substantial number of false-positive classifications (specificity 70%) in men. In women, discrimination of the FPS was better than that in men (c-index 0.73 vs 0.63, respectively). However, because of the low baseline risk of CHD and limited discriminatory power, only 33% of all CHD events occurred in women classified as high risk. The FPS need recalibration for elderly men with better incorporation of the effect of age. In elderly women, FPS perform reasonably well. However, maintaining the rational of the high-risk threshold requires better performing models for a population with low incidence of CHD.
ERIC Educational Resources Information Center
Jang, Eun-Young
2017-01-01
In recent decades, recruiting foreign professors (FPs) has become a noticeable trend at South Korean higher education institutions (HEIs) as they attempt to internationalize. However, little scholarly attention has been paid to the question of what is actually happening in classrooms as a result of this rapid influx of FPs and the associated…
This study was designed to develop and validate a short-term in vivo protocol termed the Fetal Phthalate Screen (FPS) to detect phthalate esters (PEs) and other chemicals that disrupt fetal testosterone synthesis and testis gene expression in rats. We propose that the FPS can be ...
Game Coaching System Design and Development: A Retrospective Case Study of FPS Trainer
ERIC Educational Resources Information Center
Tan, Wee Hoe
2013-01-01
This paper is a retrospective case study of a game-based learning (GBL) researcher who cooperated with a professional gamer and a team of game developers to design and develop a coaching system for First-Person Shooter (FPS) players. The GBL researcher intended to verify the ecological validity of a model of cooperation; the developers wanted to…
SH2 Domain-Based FRET Biosensor for Measuring BCR-ABL Activity in Living CML Cells.
Fujioka, Mari; Asano, Yumi; Nakada, Shigeyuki; Ohba, Yusuke
2017-01-01
Fluorescent proteins (FPs) displaying distinct spectra have shed their light on a wide range of biological functions. Moreover, sophisticated biosensors engineered to contain single or multiple FPs, including Förster resonance energy transfer (FRET)-based biosensors, spatiotemporally reveal the molecular mechanisms underlying a variety of pathophysiological processes. However, their usefulness for applied life sciences has yet to be fully explored. Recently, our research group has begun to expand the potential of FPs from basic biological research to the clinic. Here, we describe a method to evaluate the responsiveness of leukemia cells from patients to tyrosine kinase inhibitors using a biosensor based on FP technology and the principle of FRET. Upon phosphorylation of the tyrosine residue of the biosensor, binding of the SH2 domain to phosphotyrosine induces conformational change of the biosensor and brings the donor and acceptor FPs into close proximity. Therefore, kinase activity and response to kinase inhibitors can be monitored by an increase and a decrease in FRET efficiency, respectively. As in basic research, this biosensor resolves hitherto arduous tasks and may provide innovative technological advances in clinical laboratory examinations. State-of-the-art detection devices that enable such innovation are also introduced.
SPADAS: a high-speed 3D single-photon camera for advanced driver assistance systems
NASA Astrophysics Data System (ADS)
Bronzi, D.; Zou, Y.; Bellisai, S.; Villa, F.; Tisa, S.; Tosi, A.; Zappa, F.
2015-02-01
Advanced Driver Assistance Systems (ADAS) are the most advanced technologies to fight road accidents. Within ADAS, an important role is played by radar- and lidar-based sensors, which are mostly employed for collision avoidance and adaptive cruise control. Nonetheless, they have a narrow field-of-view and a limited ability to detect and differentiate objects. Standard camera-based technologies (e.g. stereovision) could balance these weaknesses, but they are currently not able to fulfill all automotive requirements (distance range, accuracy, acquisition speed, and frame-rate). To this purpose, we developed an automotive-oriented CMOS single-photon camera for optical 3D ranging based on indirect time-of-flight (iTOF) measurements. Imagers based on Single-photon avalanche diode (SPAD) arrays offer higher sensitivity with respect to CCD/CMOS rangefinders, have inherent better time resolution, higher accuracy and better linearity. Moreover, iTOF requires neither high bandwidth electronics nor short-pulsed lasers, hence allowing the development of cost-effective systems. The CMOS SPAD sensor is based on 64 × 32 pixels, each able to process both 2D intensity-data and 3D depth-ranging information, with background suppression. Pixel-level memories allow fully parallel imaging and prevents motion artefacts (skew, wobble, motion blur) and partial exposure effects, which otherwise would hinder the detection of fast moving objects. The camera is housed in an aluminum case supporting a 12 mm F/1.4 C-mount imaging lens, with a 40°×20° field-of-view. The whole system is very rugged and compact and a perfect solution for vehicle's cockpit, with dimensions of 80 mm × 45 mm × 70 mm, and less that 1 W consumption. To provide the required optical power (1.5 W, eye safe) and to allow fast (up to 25 MHz) modulation of the active illumination, we developed a modular laser source, based on five laser driver cards, with three 808 nm lasers each. We present the full characterization of the 3D automotive system, operated both at night and during daytime, in both indoor and outdoor, in real traffic, scenario. The achieved long-range (up to 45m), high dynamic-range (118 dB), highspeed (over 200 fps) 3D depth measurement, and high precision (better than 90 cm at 45 m), highlight the excellent performance of this CMOS SPAD camera for automotive applications.
Serino, Silvia; Pedroli, Elisa; Tuena, Cosimo; De Leo, Gianluca; Stramba-Badiale, Marco; Goulene, Karine; Mariotti, Noemi G; Riva, Giuseppe
2017-01-01
A growing body of evidence suggests that people with Alzheimer's Disease (AD) show compromised spatial abilities. In addition, there exists from the earliest stages of AD a specific impairment in "mental frame syncing," which is the ability to synchronize an allocentric viewpoint-independent representation (including object-to-object information) with an egocentric one by computing the bearing of each relevant "object" in the environment in relation to the stored heading in space (i.e., information about our viewpoint contained in the allocentric viewpoint-dependent representation). The main objective of this development-of-concept trial was to evaluate the efficacy of a novel VR-based training protocol focused on the enhancement of the "mental frame syncing" of the different spatial representations in subjects with AD. We recruited 20 individuals with AD who were randomly assigned to either "VR-based training" or "Control Group." Moreover, eight cognitively healthy elderly individuals were recruited to participate in the VR-based training in order to have a different comparison group. Based on a neuropsychological assessment, our results indicated a significant improvement in long-term spatial memory after the VR-based training for patients with AD; this means that transference of improvements from the VR-based training to more general aspects of spatial cognition was observed. Interestingly, there was also a significant effect of VR-based training on executive functioning for cognitively healthy elderly individuals. In sum, VR could be considered as an advanced embodied tool suitable for treating spatial recall impairments.
Warshauer-Baker, Esther; Bonham, Vence L; Jenkins, Jean; Stevens, Nancy; Page, Zintesia; Odunlami, Adebola; McBride, Colleen M
2008-01-01
Greater attention towards genetics as a contributor to group health differences may lead to inappropriate use of race/ethnicity and gender as genetic heuristics and exacerbate health disparities. As part of a web-based survey, 1,035 family physicians (FPs) rated the contribution of genetics and environment to racial/ethnic and gender differences in health outcomes, and the importance of race/ethnicity and gender in their clinical decision-making. FPs attributed racial/ethnic and gender differences in health outcomes equally to environment and genetics. These beliefs were not associated with rated importance of race/ethnicity or gender in clinical decision-making. FPs appreciate the complexity of genetic and environmental influences on health differences by race/ethnicity and gender. Copyright 2008 S. Karger AG, Basel.
Image-based dynamic deformation monitoring of civil engineering structures from long ranges
NASA Astrophysics Data System (ADS)
Ehrhart, Matthias; Lienhart, Werner
2015-02-01
In this paper, we report on the vibration and displacement monitoring of civil engineering structures using a state of the art image assisted total station (IATS) and passive target markings. By utilizing the telescope camera of the total station, it is possible to capture video streams in real time with 10fps and an angular resolution of approximately 2″/px. Due to the high angular resolution resulting from the 30x optical magnification of the telescope, large distances to the object to be monitored are possible. The laser distance measurement unit integrated in the total station allows to precisely set the camera's focus position and to relate the angular quantities gained from image processing to units of length. To accurately measure the vibrations and displacements of civil engineering structures, we use circular target markings rigidly attached to the object. The computation of the targets' centers is performed by a least squares adjustment of an ellipse according to the Gauß-Helmert model from which the parameters of the ellipse and their standard deviations are derived. In laboratory experiments, we show that movements can be detected with an accuracy of better than 0.2mm for single frames and distances up to 30m. For static applications, where many video frames can be averaged, accuracies of better than 0.05mm are possible. In a field test on a life-size footbridge, we compare the vibrations measured by the IATS to reference values derived from accelerometer measurements.
NASA Astrophysics Data System (ADS)
Zhou, Renjie; Jin, Di; Yaqoob, Zahid; So, Peter T. C.
2017-02-01
Due to the large number of available mirrors, the patterning speed, low-cost, and compactness, digital-micromirror devices (DMDs) have been extensively used in biomedical imaging system. Recently, DMDs have been brought to the quantitative phase microscopy (QPM) field to achieve synthetic-aperture imaging and tomographic imaging. Last year, our group demonstrated using DMD for QPM, where the phase-retrieval is based on a recently developed Fourier ptychography algorithm. In our previous system, the illumination angle was varied through coding the aperture plane of the illumination system, which has a low efficiency on utilizing the laser power. In our new DMD-based QPM system, we use the Lee-holograms, which is conjugated to the sample plane, to change the illumination angles for much higher power efficiency. Multiple-angle illumination can also be achieved with this method. With this versatile system, we can achieve FPM-based high-resolution phase imaging with 250 nm lateral resolution using the Rayleigh criteria. Due to the use of a powerful laser, the imaging speed would only be limited by the camera acquisition speed. With a fast camera, we expect to achieve close to 100 fps phase imaging speed that has not been achieved in current FPM imaging systems. By adding reference beam, we also expect to achieve synthetic-aperture imaging while directly measuring the phase of the sample fields. This would reduce the phase-retrieval processing time to allow for real-time imaging applications in the future.
Dobrev, I.; Furlong, C.; Cheng, J. T.; Rosowski, J. J.
2014-01-01
In this paper, we propose a multi-pulsed double exposure (MPDE) acquisition method to quantify in full-field-of-view the transient (i.e., >10 kHz) acoustically induced nanometer scale displacements of the human tympanic membrane (TM or eardrum). The method takes advantage of the geometrical linearity and repeatability of the TM displacements to enable high-speed measurements with a conventional camera (i.e., <20 fps). The MPDE is implemented on a previously developed digital holographic system (DHS) to enhance its measurement capabilities, at a minimum cost, while avoiding constraints imposed by the spatial resolutions and dimensions of high-speed (i.e., >50 kfps) cameras. To our knowledge, there is currently no existing system to provide such capabilities for the study of the human TM. The combination of high temporal (i.e., >50 kHz) and spatial (i.e., >500k data points) resolutions enables measurements of the temporal and frequency response of all points across the surface of the TM simultaneously. The repeatability and accuracy of the MPDE method are verified against a Laser Doppler Vibrometer (LDV) on both artificial membranes and ex-vivo human TMs that are acoustically excited with a sharp (i.e., <100 μs duration) click. The measuring capabilities of the DHS, enhanced by the MPDE acquisition method, allow for quantification of spatially dependent motion parameters of the TM, such as modal frequencies, time constants, as well as inferring local material properties. PMID:25780271
... clock is out of sync with the normal day-night cycle and causes a disrupted sleep schedule.) Tasimelteon ... It is usually taken without food once a day before bedtime. Take tasimelteon at the same time every night. If you are unable to take tasimelteon at ...
Wiley, Daniel A; Strogatz, Steven H; Girvan, Michelle
2006-03-01
We suggest a new line of research that we hope will appeal to the nonlinear dynamics community, especially the readers of this Focus Issue. Consider a network of identical oscillators. Suppose the synchronous state is locally stable but not globally stable; it competes with other attractors for the available phase space. How likely is the system to synchronize, starting from a random initial condition? And how does the probability of synchronization depend on the way the network is connected? On the one hand, such questions are inherently difficult because they require calculation of a global geometric quantity, the size of the "sync basin" (or, more formally, the measure of the basin of attraction for the synchronous state). On the other hand, these questions are wide open, important in many real-world settings, and approachable by numerical experiments on various combinations of dynamical systems and network topologies. To give a case study in this direction, we report results on the sync basin for a ring of n > 1 identical phase oscillators with sinusoidal coupling. Each oscillator interacts equally with its k nearest neighbors on either side. For k/n greater than a critical value (approximately 0.34, obtained analytically), we show that the sync basin is the whole phase space, except for a set of measure zero. As k/n passes below this critical value, coexisting attractors are born in a well-defined sequence. These take the form of uniformly twisted waves, each characterized by an integer winding number q, the number of complete phase twists in one circuit around the ring. The maximum stable twist is proportional to n/k; the constant of proportionality is also obtained analytically. For large values of n/k, corresponding to large rings or short-range coupling, many different twisted states compete for their share of phase space. Our simulations reveal that their basin sizes obey a tantalizingly simple statistical law: the probability that the final state has q twists follows a Gaussian distribution with respect to q. Furthermore, as n/k increases, the standard deviation of this distribution grows linearly with square root of n/k. We have been unable to explain either of these last two results by anything beyond a hand-waving argument.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flynn, Charles Joseph
The objective of this project was to design and build a cost competitive, more efficient heating, ventilation, and air conditioning (HVAC) motor than what is currently available on the market. Though different potential motor architectures among QMP’s primary technology platforms were investigated and evaluated, including through the building of numerous prototypes, the project ultimately focused on scaling up QM Power, Inc.’s (QMP) Q-Sync permanent magnet synchronous motors from available sub-fractional horsepower (HP) sizes for commercial refrigeration fan applications to larger fractional horsepower sizes appropriate for HVAC applications, and to add multi-speed functionality. The more specific goal became the research, design,more » development, and testing of a prototype 1/2 HP Q-Sync motor that has at least two operating speeds and 87% peak efficiency compared to incumbent electronically commutated motors (EC or ECM, also known as brushless direct current (DC) motors), the heretofore highest efficiency HVACR fan motor solution, at approximately 82% peak efficiency. The resulting motor prototype built achieved these goals, hitting 90% efficiency and .95 power factor at full load and speed, and 80% efficiency and .7 power factor at half speed. Q-Sync, developed in part through a DOE SBIR grant (Award # DE-SC0006311), is a novel, patented motor technology that improves on electronically commutated permanent magnet motors through an advanced electronic circuit technology. It allows a motor to “sync” with the alternating current (AC) power flow. It does so by eliminating the constant, wasteful power conversions from AC to DC and back to AC through the synthetic creation of a new AC wave on the primary circuit board (PCB) by a process called pulse width modulation (PWM; aka electronic commutation) that is incessantly required to sustain motor operation in an EC permanent magnet motor. The Q-Sync circuit improves the power factor of the motor by removing all failure prone capacitors from the power stage. Q-Sync’s simpler electronics also result in higher efficiency because it eliminates the power required by the PCB to perform the obviated power conversions and PWM processes after line synchronous operating speed is reached in the first 5 seconds of operation, after which the PWM circuits drop out and a much less energy intensive “pass through” circuit takes over, allowing the grid-supplied AC power to sustain the motor’s ongoing operation.« less
2013-01-01
Background The ‘predictD algorithm’ provides an estimate of the level and profile of risk of the onset of major depression in primary care attendees. This gives us the opportunity to develop interventions to prevent depression in a personalized way. We aim to evaluate the effectiveness, cost-effectiveness and cost-utility of a new intervention, personalized and implemented by family physicians (FPs), to prevent the onset of episodes of major depression. Methods/Design This is a multicenter randomized controlled trial (RCT), with cluster assignment by health center and two parallel arms. Two interventions will be applied by FPs, usual care versus the new intervention predictD-CCRT. The latter has four components: a training workshop for FPs; communicating the level and profile of risk of depression; building up a tailored bio-psycho-family-social intervention by FPs to prevent depression; offering a booklet to prevent depression; and activating and empowering patients. We will recruit a systematic random sample of 3286 non-depressed adult patients (1643 in each trial arm), nested in 140 FPs and 70 health centers from 7 Spanish cities. All patients will be evaluated at baseline, 6, 12 and 18 months. The level and profile of risk of depression will be communicated to patients by the FPs in the intervention practices at baseline, 6 and 12 months. Our primary outcome will be the cumulative incidence of major depression (measured by CIDI each 6 months) over 18 months of follow-up. Secondary outcomes will be health-related quality of life (SF-12 and EuroQol), and measurements of cost-effectiveness and cost-utility. The inferences will be made at patient level. We shall undertake an intention-to-treat effectiveness analysis and will handle missing data using multiple imputations. We will perform multi-level logistic regressions and will adjust for the probability of the onset of major depression at 12 months measured at baseline as well as for unbalanced variables if appropriate. The economic evaluation will be approached from two perspectives, societal and health system. Discussion To our knowledge, this will be the first RCT of universal primary prevention for depression in adults and the first to test a personalized intervention implemented by FPs. We discuss possible biases as well as other limitations. Trial registration ClinicalTrials.gov identifier: NCT01151982 PMID:23782553
van den Dungen, Pim; Moll van Charante, Eric P; van de Ven, Peter M; van Marwijk, Harm W J; van der Horst, Henriëtte E; van Hout, Hein P J
2016-01-01
Despite a call for earlier diagnosis of dementia, the diagnostic yield of case finding and its impact on the mental health of patients and relatives are unclear. This study assessed the effect of a two-component intervention of case finding and subsequent care on these outcomes. In a cluster RCT we assessed whether education of family physicians (FPs; trial stage 1) resulted in more mild cognitive impairment (MCI) and dementia diagnoses among older persons in whom FPs suspected cognitive decline and whether case finding by a practice nurse and the FP (trial stage 2) added to this number of diagnoses. In addition, we assessed mental health effects of case finding and subsequent care (trial stage 2). FPs of 15 primary care practices (PCPs = clusters) judged the cognitive status of all persons ≥ 65 years. The primary outcome, new MCI and dementia diagnoses by FPs after 12 months as indicated on a list, was assessed among all persons in whom FPs suspected cognitive impairment but without a formal diagnosis of dementia. The secondary outcome, mental health of patients and their relatives, was assessed among persons consenting to participate in trial stage 2. Trial stage 1 consisted of either intervention component 1: training FPs to diagnose MCI and dementia, or control: no training. Trial stage 2 consisted of either intervention component 2: case finding of MCI and dementia and care by a trained nurse and the FP, or control: care as usual. Seven PCPs were randomized to the intervention; eight to the control condition. MCI or dementia was diagnosed in 42.3% (138/326) of persons in the intervention, and in 30.5% (98/321) in the control group (estimated difference GEE: 10.8%, OR: 1.51, 95%-CI 0.60-3.76). Among patients and relatives who consented to stage 2 of the trial (n = 145; 25%), there were no differences in mental health between the intervention and control group. We found a non-significant increase in the number of new MCI diagnoses. As we cannot exclude a clinically relevant effect, a larger study is warranted to replicate ours. Nederlands Trial Register NTR3389.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teramoto, Atsushi, E-mail: teramoto@fujita-hu.ac.jp; Fujita, Hiroshi; Yamamuro, Osamu
Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using anmore » active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Sheng; Suzuki, Kenji; MacMahon, Heber
2011-04-15
Purpose: To develop a computer-aided detection (CADe) scheme for nodules in chest radiographs (CXRs) with a high sensitivity and a low false-positive (FP) rate. Methods: The authors developed a CADe scheme consisting of five major steps, which were developed for improving the overall performance of CADe schemes. First, to segment the lung fields accurately, the authors developed a multisegment active shape model. Then, a two-stage nodule-enhancement technique was developed for improving the conspicuity of nodules. Initial nodule candidates were detected and segmented by using the clustering watershed algorithm. Thirty-one shape-, gray-level-, surface-, and gradient-based features were extracted from each segmentedmore » candidate for determining the feature space, including one of the new features based on the Canny edge detector to eliminate a major FP source caused by rib crossings. Finally, a nonlinear support vector machine (SVM) with a Gaussian kernel was employed for classification of the nodule candidates. Results: To evaluate and compare the scheme to other published CADe schemes, the authors used a publicly available database containing 140 nodules in 140 CXRs and 93 normal CXRs. The CADe scheme based on the SVM classifier achieved sensitivities of 78.6% (110/140) and 71.4% (100/140) with averages of 5.0 (1165/233) FPs/image and 2.0 (466/233) FPs/image, respectively, in a leave-one-out cross-validation test, whereas the CADe scheme based on a linear discriminant analysis classifier had a sensitivity of 60.7% (85/140) at an FP rate of 5.0 FPs/image. For nodules classified as ''very subtle'' and ''extremely subtle,'' a sensitivity of 57.1% (24/42) was achieved at an FP rate of 5.0 FPs/image. When the authors used a database developed at the University of Chicago, the sensitivities was 83.3% (40/48) and 77.1% (37/48) at an FP rate of 5.0 (240/48) FPs/image and 2.0 (96/48) FPs /image, respectively. Conclusions: These results compare favorably to those described for other commercial and noncommercial CADe nodule detection systems.« less
Clary, Christelle M; Kestens, Yan
2013-06-19
Validation studies of secondary datasets used to characterize neighborhood food businesses generally evaluate how accurately the database represents the true situation on the ground. Depending on the research objectives, the characterization of the business environment may tolerate some inaccuracies (e.g. minor imprecisions in location or errors in business names). Furthermore, if the number of false negatives (FNs) and false positives (FPs) is balanced within a given area, one could argue that the database still provides a "fair" representation of existing resources in this area. Yet, traditional validation measures do not relax matching criteria, and treat FNs and FPs independently. Through the field validation of food businesses found in a Canadian database, this paper proposes alternative criteria for validity. Field validation of the 2010 Enhanced Points of Interest (EPOI) database (DMTI Spatial®) was performed in 2011 in 12 census tracts (CTs) in Montreal, Canada. Some 410 food outlets were extracted from the database and 484 were observed in the field. First, traditional measures of sensitivity and positive predictive value (PPV) accounting for every single mismatch between the field and the database were computed. Second, relaxed measures of sensitivity and PPV that tolerate mismatches in business names or slight imprecisions in location were assessed. A novel measure of representativity that further allows for compensation between FNs and FPs within the same business category and area was proposed. Representativity was computed at CT level as ((TPs +|FPs-FNs|)/(TPs+FNs)), with TPs meaning true positives, and |FPs-FNs| being the absolute value of the difference between the number of FNs and the number of FPs within each outlet category. The EPOI database had a "moderate" capacity to detect an outlet present in the field (sensitivity: 54.5%) or to list only the outlets that actually existed in the field (PPV: 64.4%). Relaxed measures of sensitivity and PPV were respectively 65.5% and 77.3%. The representativity of the EPOI database was 77.7%. The novel measure of representativity might serve as an alternative to traditional validity measures, and could be more appropriate in certain situations, depending on the nature and scale of the research question.
Hogenbirk, John C; Timony, Patrick E; French, Margaret G; Strasser, Roger; Pong, Raymond W; Cervin, Catherine; Graves, Lisa
2016-03-01
To assess the effect of different levels of exposure to the Northern Ontario School of Medicine's (NOSM's) distributed medical education programs in northern Ontario on FPs' practice locations. Cross-sectional design using longitudinal survey and administrative data. Canada. All 131 Canadian medical graduates who completed FP training in 2011 to 2013 and who completed their undergraduate (UG) medical degree or postgraduate (PG) residency training or both at NOSM. Exposure to NOSM's medical education program at the UG (n = 49) or PG (n = 31) level or both (n = 51). Primary practice location in September of 2014. Approximately 16% (21 of 129) of FPs were practising in rural northern Ontario, 45% (58 of 129) in urban northern Ontario, and 5% (7 of 129) in rural southern Ontario. Logistic regression found that more rural Canadian background years predicted rural practice in northern Ontario or Ontario, with odds ratios of 1.16 and 1.12, respectively. Northern Canadian background, sex, marital status, and having children did not predict practice location. Completing both UG and PG training at NOSM predicted practising in rural and northern Ontario locations with odds ratios of 4.06 to 48.62. Approximately 61% (79 of 129) of Canadian medical graduate FPs who complete at least some of their training at NOSM practise in northern Ontario. Slightly more than a quarter (21 of 79) of these FPs practise in rural northern Ontario. The FPs with more years of rural background or those with greater exposure to NOSM's medical education programs had higher odds of practising in rural northern Ontario. This study shows that NOSM is on the road to reaching one of its social accountability milestones.
Henry, Bonnie; Crabtree, Alexis; Roth, David; Blackman, Doug; Morshed, Muhammad
2012-01-01
Abstract Objective To determine physicians’ level of awareness and knowledge of Lyme disease (LD) in a low-prevalence area and whether physicians’ practices align with current guidelines for treatment of LD. Design A 23-item questionnaire assessing demographic characteristics, general knowledge about LD, laboratory testing for LD, and responses to 3 clinical scenarios. Setting British Columbia (BC). Participants Pediatricians, FPs, and internal medicine specialists who were licensed to practise in BC. Main outcome measures Knowledge of signs and symptoms of LD, beliefs about risk of LD, attitudes toward LD in patients in their practices, and application of accepted practice guidelines for the treatment of LD in clinical scenarios. Results Overall, 80.6% of respondents were FPs. Average knowledge score was 72.5% for FPs and 75.0% for other specialists. Most respondents (75.6% of FPs and 71.8% of other specialists) underestimated the occurrence of erythema migrans (EM), and only 26.1% and 28.3%, respectively, knew that EM alone was diagnostic for LD. A total of 30.5% of FPs and 12.1% of other specialists reported having treated a patient for the disease despite not believing that the patient had LD. Of all the respondents, 62.1% knew that LD was a reportable disease in BC. Respondents’ reports of risk of LD in their areas were appropriately associated with actual risk based on ecological niche. Conclusion Physicians are knowledgeable about the clinical signs and symptoms of LD and aware of the risk of the disease despite being in a low-endemic area. Physicians in BC are comfortable with treating patients empirically for LD. Education is needed to inform physicians that EM is diagnostic and no laboratory testing is indicated before treatment. Raising awareness among physicians that LD is reportable might improve reporting of future cases. PMID:22734172
A pay-for-performance system for civil service doctors: the Indonesian experiment.
Chernichovsky, D; Bayulken, C
1995-07-01
In 1980 the Government of Indonesia proposed the introduction of a pay-for-performance system, the Functional Position System (FPS), for certain occupational categories of civil servants to provide a career development path and stimulate productivity (Government of Indonesia. Government Ordinance No. 3, 1980 Concerning Appointment to Civil Service Rank. Jakarta, 1980). The FPS, a bold pay concept in the civil service, links pay to skills and performance. In 1987, instructions were issued for doctors to be included in the system (Government of Indonesia, Credit Scores for Doctors. Circular Issued by the Ministry of Health and the Agency for Administration of the Civil Service No. 614/MENKES/E/VIII/1987 and No. 16/SE/1987). In this paper we evaluate how well the system-which in principle could be applicable to both developed and developing economies--can meet its stated objectives for Indonesian doctors working in the community, and for Indonesian health policy objectives as stated in the country's last five-year development plan "Repelita V" (Government of Indonesia. The Fifth Five-year Development Plan (Repelita V) 1989-1994. Jakarta, Indonesia, 1989). The FPS is particularly innovative in the Indonesian environment where wages are low and comparatively uniform, reflecting a philosophy of 'shared poverty', and vary primarily by seniority. The FPS has, however, several conceptual and practical shortcomings. The design of the reward system disregards effort or time inputs, as well as other inputs needed per unit of reward. Consequently, the FPS can not be used as an effective incentive system promoting professional excellence and health policy objectives. Practically, the system hardly provides an effective alternative for career development among community physicians.(ABSTRACT TRUNCATED AT 250 WORDS)
Estimating the distance separating fluorescent protein FRET pairs
van der Meer, B. Wieb; Blank, Paul S.
2014-01-01
Förster resonance energy transfer (FRET) describes a physical phenomenon widely applied in biomedical research to estimate separations between biological molecules. Routinely, genetic engineering is used to incorporate spectral variants of the green fluorescent protein (GFPs), into cellular expressed proteins. The transfer efficiency or rate of energy transfer between donor and acceptor FPs is then assayed. As appreciable FRET occurs only when donors and acceptors are in close proximity (1–10 nm), the presence of FRET may indicate that the engineered proteins associate as interacting species. For a homogeneous population of FRET pairs the separations between FRET donors and acceptors can be estimated from a measured FRET efficiency if it is assumed that donors and acceptors are randomly oriented and rotate extensively during their excited state (dynamic regime). Unlike typical organic fluorophores, the rotational correlation-times of FPs are typically much longer than their fluorescence lifetime; accordingly FPs are virtually static during their excited state. Thus, estimating separations between FP FRET pairs is problematic. To overcome this obstacle, we present here a simple method for estimating separations between FPs using the experimentally measured average FRET efficiency. This approach assumes that donor and acceptor fluorophores are randomly oriented, but do not rotate during their excited state (static regime). This approach utilizes a Monte-Carlo simulation generated look-up table that allows one to estimate the separation, normalized to the Förster distance, from the average FRET efficiency. Assuming a dynamic regime overestimates the separation significantly (by 10% near 0.5 and 30% near 0.75 efficiencies) compared to assuming a static regime, which is more appropriate for estimates of separations between FPs. PMID:23811334
Yamane, Kentaro; Kai, Nobuo; Mazaki, Tetsuro; Miyamoto, Tadashi; Matsushita, Tomohiro
2018-06-13
Long-term exposure to radiation can lead to gene mutations and increase the risk of cancer. Low rate fluoroscopy has the potential to reduce the radiation exposure for both the examiner and the patient during various fluoroscopic procedures. The purpose of this study was to evaluate the impact of low rate fluoroscopy on reducing an examiner's radiation dose during nerve root block. A total of 101 lumbar nerve root block examinations were performed at our institute during a 6-month period. During the first 3 months, low rate fluoroscopy was performed at 7.5 frames/s (FPS) in 54 examinations, while 47 were performed at 15 FPS during the last 3 months. The examiner wore a torso protector, a neck protector, radiation protection gloves, and radiation protection glasses. Optically stimulated luminescence (OSL) dosimeter badges were placed on both the inside and the outside of each protector. The dosimeters were exchanged every month. Radiation doses (mSv) were measured as the integrated radiation quantity every month from the OSL dosimeters. The effective and equivalent doses for the hands, skin, and eyes were investigated. The mean monthly equivalent doses were significantly lower both inside and outside the hand protector for the 7.5 FPS versus 15 FPS (inside; P = 0.021, outside; P = 0.024). There were no significant differences between the two groups for the mean monthly calculated effective dose for each protector's condition. Radiation exposure was significantly reduced for the skin on the examiner's hand when using low rate fluoroscopy at 7.5 FPS, with no noticeable decrease in image quality or prolonged fluoroscopy time. Copyright © 2018. Published by Elsevier B.V.
Role of dopamine receptors in the ventral tegmental area in conditioned fear.
de Oliveira, Amanda Ribeiro; Reimer, Adriano Edgar; Brandão, Marcus Lira
2009-05-16
The increased startle reflex in the presence of a stimulus that has been previously paired with footshock has been termed fear-potentiated startle (FPS) and is considered a reliable index of anxiety. Some studies have suggested an association between stressful situations and alterations in dopaminergic (DA) transmission. Many studies converge on the hypothesis that the mesocorticolimbic pathway, originating from DA neurons in the ventral tegmental area (VTA), is particularly sensitive to fear-arousing stimuli. The present study explored the involvement of VTA DA receptors in the acquisition and expression of conditioned fear to a light conditioned stimulus (CS). We evaluated the effects of intra-VTA administration of SKF 38393 (D(1) agonist), SCH 23390 (D(1) antagonist), quinpirole (D(2) agonist), and sulpiride (D(2) antagonist) on FPS. All drugs were administered bilaterally into the VTA (1.0 microg/0.2 microl/site). Locomotor activity/exploration and motor coordination were evaluated in the open-field and rotarod tests. None of the drugs produced significant effects on FPS when injected before conditioning, indicating that VTA DA receptors are not involved in the acquisition of conditioned fear to a light-CS. In contrast, when injected before the test session, quinpirole significantly reduced FPS, whereas the other drugs had no effect. Quinpirole's ability to decrease FPS may be the result of an action on VTA D(2) presynaptic autoreceptors that decrease dopamine levels in terminal fields of the mesocorticolimbic pathway. Altogether, the present results suggest the importance of VTA DA neurons in the fear-activating effects of Pavlovian conditioning. In addition to demonstrating the importance of dopaminergic mechanisms in the motivational consequences of footshock, the present findings also indicate that these neural circuits are mainly involved in the expression, rather than acquisition, of conditioned fear.
Taylor, Kathryn A; Stocks, Nigel; Marshall, Helen S
2014-07-16
To determine factors influencing Family Physician (FP) uptake of non government-funded vaccines, and to explore FP attitudes towards the introduction and use of a new vaccine to protect against serogroup B meningococcal disease to inform its future introduction into the Australian Immunisation Schedule. Quantitative, self-administered state-wide questionnaire mailed to all FPs in South Australia (n=1786). Results from 523 FP respondents in South Australia, collected between June and October 2013. Self-reported immunisation counselling practices; and knowledge, attitudes and barriers to prescribing of Meningococcal B (Men B) vaccine and other recommended, non-funded immunisations. The response rate was 30% (n=523). While most (59%) respondents had worked in general practice for over 20 years, only 39% of all respondents had ever had personal or professional experience with a case of invasive meningococcal disease (IMD). Most FPs (63%) were aware that a meningococcal B vaccine was being developed, and 93% of respondents agreed that this vaccine should be government-funded. FPs ranked Men B vaccine as the highest priority to receive funding of eight currently non-funded immunisation strategies. High vaccine cost and low patient socioeconomic status were identified as definite barriers to prescribing non-funded vaccines by 59% of respondents. Past IMD experience significantly affected attitudes and prescribing practices. IMD, while encountered rarely in clinical practice, is considered an important disease to vaccinate against by FPs. Cost and perceived low socioeconomic status of patients are substantial barriers to FPs prescribing Men B and other non-funded vaccines, and inclusion of such vaccines on the National Immunisation Program is likely to improve equity of access. Copyright © 2014 Elsevier Ltd. All rights reserved.
Krishnan, Balaji; Scott, Michael T.; Pollandt, Sebastian; Schroeder, Bradley; Kurosky, Alexander; Shinnick-Gallagher, Patricia
2016-01-01
Long-term memory (LTM) of fear stores activity dependent modifications that include changes in amygdala signaling. Previously, we identified an enhanced probability of release of glutamate mediated signaling to be important in rat fear potentiated startle (FPS), a well-established translational behavioral measure of fear. Here, we investigated short- and long-term synaptic plasticity in FPS involving metabotropic glutamate receptors (mGluRs) and associated downstream proteomic changes in the thalamic-lateral amygdala pathway (Th-LA). Aldolase A, an inhibitor of phospholipase D (PLD), expression was reduced, concurrent with significantly elevated PLD protein expression. Blocking the PLD-mGluR signaling significantly reduced PLD activity. While transmitter release probability increased in FPS, PLD-mGluR agonist and antagonist actions were occluded. In the unpaired group (UNP), blocking the PLD-mGluR increased while activating the receptor decreased transmitter release probability, consistent with decreased synaptic potentials during tetanic stimulation. FPS Post-tetanic potentiation (PTP) immediately following long-term potentiation (LTP) induction was significantly increased. Blocking PLD-mGluR signaling prevented PTP and reduced cumulative PTP probability but not LTP maintenance in both groups. These effects are similar to those mediated through mGluR7, which is co-immunoprecipitated with PLD in FPS. Lastly, blocking mGluR-PLD in the rat amygdala was sufficient to prevent behavioral expression of fear memory. Thus, our study in the Th-LA pathway provides the first evidence for PLD as an important target of mGluR signaling in amygdala fear-associated memory. Importantly, the PLD-mGluR provides a novel therapeutic target for treating maladaptive fear memories in posttraumatic stress and anxiety disorders. PMID:26748024
Electronic construction collaboration system -- final phase.
DOT National Transportation Integrated Search
2014-09-01
This phase of the research project involved two major efforts: (1) Complete the implementation of AEC-Sync (formerly known as : Attolist) on the Iowa Falls Arch Bridge project and (2) develop a WPMS for projects under $10 million. : For the first maj...
MO-A-BRD-06: In Vivo Cherenkov Video Imaging to Verify Whole Breast Irradiation Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, R; Glaser, A; Jarvis, L
Purpose: To show in vivo video imaging of Cherenkov emission (Cherenkoscopy) can be acquired in the clinical treatment room without affecting the normal process of external beam radiation therapy (EBRT). Applications of Cherenkoscopy, such as patient positioning, movement tracking, treatment monitoring and superficial dose estimation, were examined. Methods: In a phase 1 clinical trial, including 12 patients undergoing post-lumpectomy whole breast irradiation, Cherenkov emission was imaged with a time-gated ICCD camera synchronized to the radiation pulses, during 10 fractions of the treatment. Images from different treatment days were compared by calculating the 2-D correlations corresponding to the averaged image. Anmore » edge detection algorithm was utilized to highlight biological features, such as the blood vessels. Superficial dose deposited at the sampling depth were derived from the Eclipse treatment planning system (TPS) and compared with the Cherenkov images. Skin reactions were graded weekly according to the Common Toxicity Criteria and digital photographs were obtained for comparison. Results: Real time (fps = 4.8) imaging of Cherenkov emission was feasible and feasibility tests indicated that it could be improved to video rate (fps = 30) with system improvements. Dynamic field changes due to fast MLC motion were imaged in real time. The average 2-D correlation was about 0.99, suggesting the stability of this imaging technique and repeatability of patient positioning was outstanding. Edge enhanced images of blood vessels were observed, and could serve as unique biological markers for patient positioning and movement tracking (breathing). Small discrepancies exists between the Cherenkov images and the superficial dose predicted from the TPS but the former agreed better with actual skin reactions than did the latter. Conclusion: Real time Cherenkoscopy imaging during EBRT is a novel imaging tool that could be utilized for patient positioning, movement tracking, treatment monitoring, superficial dose and skin reaction estimation and prediction.« less
Hokamura, Ayaka; Fujino, Kanako; Isoda, Yoshiko; Arizono, Koji; Shiratsuchi, Hideki; Matsusaki, Hiromi
2015-01-01
Pseudomonas sp. 61-3 accumulates two types of polyhydroxyalkanoates (PHAs), poly(3-hydroxybutyrate) [P(3HB)], and poly(3HB-co-3-hydroxyalkanoates) [P(3HB-co-3HA)], and some proteins associated with their PHA granules have been identified. To date, PhaFPs (GA36) and PhaIPs (GA18) were identified from P(3HB-co-3HA) granules. In this study, the gene encoding GA24 associated with P(3HB) granule was identified as phbPPs. PhbPPs was composed of 192 amino acids with a calculated molecular mass of 20.4 kDa and was assumed to be a phasin. phbFPs gene and unknown ORF were also found on phb locus. PhbFPs was anticipated to be the transcriptional repressor of phbPPs gene. PhbPPs was bound to the P(3HB-co-3HA) granules with 3HB composition of more than 87 mol%, and PhaIPs and PhaFPs were bound to the P(3HB-co-3HA) granules with 3HA (C6-C12) composition of more than 13 mol% in the producing cells, suggesting that localization of these proteins is attributed to the monomer compositions of the copolymers.
Mathur, Medha; Goyal, Ram Chandra; Mathur, Navgeet
2017-05-01
Quality of sterilization services is a matter of concern in India because population control is a necessity. Family Planning Sterilization (FPS) services provided at public health care facilities need to be as per Standard Operating Procedures. To assess the quality of FPS services by audit of case records at selected health care facilities. This cross-sectional study was conducted for two and a half year duration at selected public health care facilities of central India by simple random sampling where FPS services were provided. As per the standards of Government of India, case records were audited and compliance was calculated to assess the quality of services. Results of record audit were satisfactory but important criteria like previous contraceptive history and postoperative counselling were found to be deviated from standards. At Primary Health Centres (PHCs) only 89.5% and at Community Health Centres (CHCs) 58.7% of records were having details of previous contraceptive history. Other criteria like mental illness (only 70% at CHCs) assessment were also inadequate. Although informed consent was found to be having 100% compliance in all records. Quality of care in FPS services is the matter of concern in present scenario for better quality of services. This study may enlighten the policy makers regarding improvements needed for providing quality care.
Correlative Imaging of Fluorescent Proteins in Resin-Embedded Plant Material1
Bell, Karen; Mitchell, Steve; Paultre, Danae; Posch, Markus; Oparka, Karl
2013-01-01
Fluorescent proteins (FPs) were developed for live-cell imaging and have revolutionized cell biology. However, not all plant tissues are accessible to live imaging using confocal microscopy, necessitating alternative approaches for protein localization. An example is the phloem, a tissue embedded deep within plant organs and sensitive to damage. To facilitate accurate localization of FPs within recalcitrant tissues, we developed a simple method for retaining FPs after resin embedding. This method is based on low-temperature fixation and dehydration, followed by embedding in London Resin White, and avoids the need for cryosections. We show that a palette of FPs can be localized in plant tissues while retaining good structural cell preservation, and that the polymerized block face can be counterstained with cell wall probes. Using this method we have been able to image green fluorescent protein-labeled plasmodesmata to a depth of more than 40 μm beneath the resin surface. Using correlative light and electron microscopy of the phloem, we were able to locate the same FP-labeled sieve elements in semithin and ultrathin sections. Sections were amenable to antibody labeling, and allowed a combination of confocal and superresolution imaging (three-dimensional-structured illumination microscopy) on the same cells. These correlative imaging methods should find several uses in plant cell biology. PMID:23457228
InSync Adaptive Traffic Control System for the Veterans Memorial Hwy Corridor on Long Island, NY
DOT National Transportation Integrated Search
2012-08-01
This report documents Rhythm Engineerings adaptive traffic control system field installation performed : by New York State Department of Transportation (NYSDOT) along Veterans Memorial Hwy in Long : Island, NY. This report reviews the reason for t...
Pycock, Jonathan
2015-03-07
Jonathan Pycock is one of three equine claims consultants with the Veterinary Defence Society. His career in equine reproduction, and lecturing on the same topic, has given him the opportunity to work and travel widely, and ensure his work/life balance stays in sync. British Veterinary Association.
IN-SYNC. V. Stellar Kinematics and Dynamics in the Orion A Molecular Cloud
NASA Astrophysics Data System (ADS)
Da Rio, Nicola; Tan, Jonathan C.; Covey, Kevin R.; Cottaar, Michiel; Foster, Jonathan B.; Cullen, Nicholas C.; Tobin, John; Kim, Jinyoung S.; Meyer, Michael R.; Nidever, David L.; Stassun, Keivan G.; Chojnowski, S. Drew; Flaherty, Kevin M.; Majewski, Steven R.; Skrutskie, Michael F.; Zasowski, Gail; Pan, Kaike
2017-08-01
The kinematics and dynamics of young stellar populations enable us to test theories of star formation. With this aim, we continue our analysis of the SDSS-III/APOGEE IN-SYNC survey, a high-resolution near-infrared spectroscopic survey of young clusters. We focus on the Orion A star-forming region, for which IN-SYNC obtained spectra of ˜2700 stars. In Paper IV we used these data to study the young stellar population. Here we study the kinematic properties through radial velocities (v r ). The young stellar population remains kinematically associated with the molecular gas, following a ˜ 10 {km} {{{s}}}-1 gradient along the filament. However, near the center of the region, the v r distribution is slightly blueshifted and asymmetric; we suggest that this population, which is older, is slightly in the foreground. We find evidence for kinematic subclustering, detecting statistically significant groupings of colocated stars with coherent motions. These are mostly in the lower-density regions of the cloud, while the ONC radial velocities are smoothly distributed, consistent with it being an older, more dynamically evolved cluster. The velocity dispersion {σ }v varies along the filament. The ONC appears virialized, or just slightly supervirial, consistent with an old dynamical age. Here there is also some evidence for ongoing expansion, from a v r -extinction correlation. In the southern filament, {σ }v is ˜2-3 times larger than virial in the L1641N region, where we infer a superposition along the line of sight of stellar subpopulations, detached from the gas. In contrast, {σ }v decreases toward L1641S, where the population is again in agreement with a virial state.
NASA Astrophysics Data System (ADS)
Kondo, S.; Yoshida, A.; Takahashi, Y.; Chikada, S.; Adachi, T.; Sakanoi, T.
2007-12-01
Transient optical phenomena in the mesosphere and lower ionosphere called transient luminous events (TLEs) have been investigated extensively since the first discovery in 1989. In the lower ionosphere, elves are generated by the electromagnetic pulses (EMPs) radiated from the intense lightning current. On the ground-based observation, cameras can not always identify the occurrence of elves because elves emission is sometimes reduced significantly by the atmosphere and blocked by clouds. Therefore, it has been difficult to determine the threshold of intensity of EMPs necessary for initiation of elves. We simultaneously carried out optical and sferics measurements for TLEs and lightning discharges using a high altitude balloon launched at Sanriku Balloon Center on the night of August 25 / 26 in 2006. We fixed four CCD cameras on the gondola, each of which had horizontal FOV of ~100 degree. They cover 360 degree in horizontal direction and imaged the TLEs without atmospheric extinction nor blocking by clouds. The frame rate is 30 fps. We installed three dipole antennas at the gondola, which received the vertical and horizontal electric fields radiated from lightning discharges. The frequency range of the VLF receiver is 1-25 kHz. We also make use of VLF sferics data obtained by ground-based antennas located at Tohoku University in Sendai. We picked up six elves from the image data set obtained by the CCD cameras, and examined the maximum amplitudes of the vertical electric field for 22 lightning discharge events including the six elves events observed both at the balloon and at Sendai. It is found that the maximum amplitudes of the vertical electric field in the five elves events are much larger than those in the other lightning events. We estimate the intensity of the radiated electric field necessary for elves. About one elves event, we don't see intense vertical electric field in the balloon data.
NASA Astrophysics Data System (ADS)
Zhang, Jian James; Rajabhandharaks, Danop; Xuan, Jason Rongwei; Chia, Ray W. J.; Hasenberg, Tom
2014-03-01
Calculus migration is a common problem during ureteroscopic laser lithotripsy procedure to treat urolithiasis. A conventional experimental method to characterize calculus migration utilized a hosting container (e.g. a "V" grove or a test tube). These methods, however, demonstrated large variation and poor detectability, possibly attributing to friction between the calculus and the container on which the calculus was situated. In this study, calculus migration was investigated using a pendulum model suspended under water to eliminate the aforementioned friction. A high speed camera was used to study the movement of the calculus which covered zero order (displacement), 1st order (speed) and 2nd order (acceleration). A commercialized, pulsed Ho:YAG laser at 2.1 um, 365-um core fiber, and calculus phantom (Plaster of Paris, 10×10×10mm cube) were utilized to mimic laser lithotripsy procedure. The phantom was hung on a stainless steel bar and irradiated by the laser at 0.5, 1.0 and 1.5J energy per pulse at 10Hz for 1 second (i.e., 5, 10, and 15W). Movement of the phantom was recorded by a high-speed camera with a frame rate of 10,000 FPS. Maximum displacement was 1.25+/-0.10, 3.01+/-0.52, and 4.37+/-0.58 mm for 0.5, 1, and 1.5J energy per pulse, respectively. Using the same laser power, the conventional method showed <0.5 mm total displacement. When reducing the phantom size to 5×5×5mm (1/8 in volume), the displacement was very inconsistent. The results suggested that using the pendulum model to eliminate the friction improved sensitivity and repeatability of the experiment. Detailed investigation on calculus movement and other causes of experimental variation will be conducted as a future study.
A customizable commercial miniaturized 320×256 indium gallium arsenide shortwave infrared camera
NASA Astrophysics Data System (ADS)
Huang, Shih-Che; O'Grady, Matthew; Groppe, Joseph V.; Ettenberg, Martin H.; Brubaker, Robert M.
2004-10-01
The design and performance of a commercial short-wave-infrared (SWIR) InGaAs microcamera engine is presented. The 0.9-to-1.7 micron SWIR imaging system consists of a room-temperature-TEC-stabilized, 320x256 (25 μm pitch) InGaAs focal plane array (FPA) and a high-performance, highly customizable image-processing set of electronics. The detectivity, D*, of the system is greater than 1013 cm-√Hz/W at 1.55 μm, and this sensitivity may be adjusted in real-time over 100 dB. It features snapshot-mode integration with a minimum exposure time of 130 μs. The digital video processor provides real time pixel-to-pixel, 2-point dark-current subtraction and non-uniformity compensation along with defective-pixel substitution. Other features include automatic gain control (AGC), gamma correction, 7 preset configurations, adjustable exposure time, external triggering, and windowing. The windowing feature is highly flexible; the region of interest (ROI) may be placed anywhere on the imager and can be varied at will. Windowing allows for high-speed readout enabling such applications as target acquisition and tracking; for example, a 32x32 ROI window may be read out at over 3500 frames per second (fps). Output video is provided as EIA170-compatible analog, or as 12-bit CameraLink-compatible digital. All the above features are accomplished in a small volume < 28 cm3, weight < 70 g, and with low power consumption < 1.3 W at room temperature using this new microcamera engine. Video processing is based on a field-programmable gate array (FPGA) platform with a soft-embedded processor that allows for ease of integration/addition of customer-specific algorithms, processes, or design requirements. The camera was developed with the high-performance, space-restricted, power-conscious application in mind, such as robotic or UAV deployment.
Real-Time Counting People in Crowded Areas by Using Local Empirical Templates and Density Ratios
NASA Astrophysics Data System (ADS)
Hung, Dao-Huu; Hsu, Gee-Sern; Chung, Sheng-Luen; Saito, Hideo
In this paper, a fast and automated method of counting pedestrians in crowded areas is proposed along with three contributions. We firstly propose Local Empirical Templates (LET), which are able to outline the foregrounds, typically made by single pedestrians in a scene. LET are extracted by clustering foregrounds of single pedestrians with similar features in silhouettes. This process is done automatically for unknown scenes. Secondly, comparing the size of group foreground made by a group of pedestrians to that of appropriate LET captured in the same image patch with the group foreground produces the density ratio. Because of the local scale normalization between sizes, the density ratio appears to have a bound closely related to the number of pedestrians who induce the group foreground. Finally, to extract the bounds of density ratios for groups of different number of pedestrians, we propose a 3D human models based simulation in which camera viewpoints and pedestrians' proximity are easily manipulated. We collect hundreds of typical occluded-people patterns with distinct degrees of human proximity and under a variety of camera viewpoints. Distributions of density ratios with respect to the number of pedestrians are built based on the computed density ratios of these patterns for extracting density ratio bounds. The simulation is performed in the offline learning phase to extract the bounds from the distributions, which are used to count pedestrians in online settings. We reveal that the bounds seem to be invariant to camera viewpoints and humans' proximity. The performance of our proposed method is evaluated with our collected videos and PETS 2009's datasets. For our collected videos with the resolution of 320x240, our method runs in real-time with good accuracy and frame rate of around 30 fps, and consumes a small amount of computing resources. For PETS 2009's datasets, our proposed method achieves competitive results with other methods tested on the same datasets [1], [2].
Systematic characterization of maturation time of fluorescent proteins in living cells
Balleza, Enrique; Kim, J. Mark; Cluzel, Philippe
2017-01-01
Slow maturation time of fluorescent proteins limits accurate measurement of rapid gene expression dynamics and effectively reduces fluorescence signal in growing cells. We used high-precision time-lapse microscopy to characterize, at two different temperatures in E. coli, the maturation kinetics of 50 FPs that span the visible spectrum. We identified fast-maturing FPs that yield the highest signal-to-noise ratio and temporal resolution in individual growing cells. PMID:29320486
Fluorescent proteins for quantitative microscopy: important properties and practical evaluation.
Shaner, Nathan Christopher
2014-01-01
More than 20 years after their discovery, fluorescent proteins (FPs) continue to be the subject of massive engineering efforts yielding continued improvements. Among these efforts are many aspects that should be of great interest to quantitative imaging users. With new variants frequently introduced into the research community, "tried and true" FPs that have been relied on for many years may now be due for upgrades to more modern variants. However, the dizzying array of FPs now available can make the initial act of narrowing down the potential choices an intimidating prospect. This chapter describes the FP properties that most strongly impact their performance in quantitative imaging experiments, along with their physical origins as they are currently understood. A workflow for evaluating a given FP in the researcher's chosen experimental system (e.g., a specific cell line) is described. © 2014 Elsevier Inc. All rights reserved.
Defending the Doomed: Implicit Strategies Concerning Protection of First-Person Shooter Games
Munko, Daniel; Glock, Sabine; Bente, Gary
2012-01-01
Abstract Censorship of violent digital games, especially first-person shooter (FPS) games, is broadly discussed between generations. While older people are concerned about possible negative influences of these games, not only players but also nonplayers of the younger net-generation seem to deny any association with real aggressive behavior. Our study aimed at investigating defense mechanisms players and nonplayers use to defend FPS and peers with playing habits. By using a lexical decision task, we found that aggressive concepts are activated by priming the content of FPS but suppressed afterward. Only if participants were instructed to actively suppress aggressive concepts after priming, thought suppression was no longer necessary. Young people still do have negative associations with violent video games. These associations are neglected by implicitly applying defense strategies—independent of own playing habits—to protect this specific hobby, which is common for the net-generation. PMID:22515170
Spectral and energy characteristics of four-photon parametric scattering in sodium vapor
NASA Astrophysics Data System (ADS)
Vaicaitis, V.; Ignatavicius, M.; Kudriashov, V. A.; Pimenov, Iu. N.; Jakyte, R.
1987-04-01
Consideration is given to processes of four-photon interaction upon two-photon resonance excitation of the 3d level of sodium by two-frequency radiation from a monopulse picosecond YAG:Nd laser with frequency doubling and an optical parametric oscillator utilizing KDP crystrals. The spatial and frequency spectra of the four-photon parametric scattering (FPS) are recorded and studied at different sodium vapor concentrations (10 to the 15th to 10 to the 17th/cu cm) and upon both collinear and noncollinear excitation. It is shown that the observed conical structure of the FPS radiation can be interpreted from an analysis of the realization of the frequency and spatial phase-matching conditions. The dependences of the FPS radiation intensity on the exciting radiation intensity, the sodium vapor concentration, and the mismatching of the exciting radiation from the two-photon resonance are obtained.
Energy Efficient Engine: Flight propulsion system final design and analysis
NASA Technical Reports Server (NTRS)
Davis, Donald Y.; Stearns, E. Marshall
1985-01-01
The Energy Efficient Engine (E3) is a NASA program to create fuel saving technology for future transport engines. The Flight Propulsion System (FPS) is the engine designed to achieve E3 goals. Achieving these goals required aerodynamic, mechanical and system technologies advanced beyond that of current production engines. These technologies were successfully demonstrated in component rigs, a core engine and a turbofan ground test engine. The design and benefits of the FPS are presented. All goals for efficiency, environmental considerations, and economic payoff were met. The FPS has, at maximum cruise, 10.67 km (35,000 ft), M0.8, standard day, a 16.9 percent lower installed specific fuel consumption than a CF6-50C. It provides an 8.6 percent reduction in direct operating cost for a short haul domestic transport and a 16.2 percent reduction for an international long distance transport.
NASA Astrophysics Data System (ADS)
Kirishima, Akira; Amano, Yuuki; Nihei, Toshifumi; Mitsugashira, Toshiaki; Sato, Nobuaki
2010-03-01
For the recovery of fissile materials from spent nuclear fuel, we have proposed a novel reprocessing process based on selective sulfurization of fission products (FPs). The key concept of this process is utilization of unique chemical property of carbon disulfide (CS2), i.e., it works as a reductant for U3O8 but works as a sulfurizing agent for minor actinides and lanthanides. Sulfurized FPs and minor actinides (MA) are highly soluble to dilute nitric acid while UO2 and PuO2 are hardly soluble, therefore, FPs and MA can be removed from Uranium and Plutonium matrix by selective dissolution. As a feasibility study of this new concept, the sulfurization behaviours of U, Pu, Np, Am and Eu are investigated in this paper by the thermodynamical calculation, phase analysis of chemical analogue elements and tracer experiments.
Effect of rotor design tip speed on noise of a 1.21 pressure ratio model fan under static conditions
NASA Technical Reports Server (NTRS)
Loeffler, I. J.; Lieblein, S.; Stockman, N. O.
1973-01-01
Preliminary results are presented for a reverberant-field noise investigation of three fan stages designed for the same overall total pressure ratio of 1.21 at different rotor tip speeds (750, 900, and 1050 fps). The stages were tested statically in a 15-in.-dia model lift fan installed in a wing pod located in the test section of a wind tunnel. Although the fan stages produced essentially the same design pressure ratio, marked differences were observed in the variation of fan noise with fan operating speed. At design speed, the forward-radiated sound power level was approximately the same for the 750 and 900 fps stages. For the 1050 fps stage, the design-speed forward-radiated power level was about 7 dB higher due to the generation of multiple pure tone noise.
Liu, Chuanlei; Zhang, Weihua; Ungar, Kurt; Korpach, Ed; White, Brian; Benotto, Mike; Pellerin, Eric
2018-05-07
This work explores the application of Health Canada's Fixed Point Surveillance (FPS) network for cosmic ray monitoring and dose estimation purposes. This network is comprised of RS250 3 inch by 3 inch Sodium Iodide (NaI) spectroscopic dosimeters distributed throughout Canada. The RS250's high channel count rate responds to the electromagnetic and muonic components of cosmic ray shower. These count rates are used to infer cosmic ray doses throughout FPS locations. The derived dose was found to have an accuracy within 6.5% deviation relative to theoretical calculation. The solar cycle effect and meteorologically induced fluctuation can be realistically reflected in the estimated dose. This work may serve as a basis to enable the FPS network to monitor and report both terrestrial and cosmic radiation in quasi-real time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
FPGA implementation for real-time background subtraction based on Horprasert model.
Rodriguez-Gomez, Rafael; Fernandez-Sanchez, Enrique J; Diaz, Javier; Ros, Eduardo
2012-01-01
Background subtraction is considered the first processing stage in video surveillance systems, and consists of determining objects in movement in a scene captured by a static camera. It is an intensive task with a high computational cost. This work proposes an embedded novel architecture on FPGA which is able to extract the background on resource-limited environments and offers low degradation (produced because of the hardware-friendly model modification). In addition, the original model is extended in order to detect shadows and improve the quality of the segmentation of the moving objects. We have analyzed the resource consumption and performance in Spartan3 Xilinx FPGAs and compared to others works available on the literature, showing that the current architecture is a good trade-off in terms of accuracy, performance and resources utilization. With less than a 65% of the resources utilization of a XC3SD3400 Spartan-3A low-cost family FPGA, the system achieves a frequency of 66.5 MHz reaching 32.8 fps with resolution 1,024 × 1,024 pixels, and an estimated power consumption of 5.76 W.
Atomization of Impinging Droplets on Superheated Superhydrophobic Surfaces
NASA Astrophysics Data System (ADS)
Emerson, Preston; Crockett, Julie; Maynes, Daniel
2017-11-01
Water droplets impinging smooth superheated surfaces may be characterized by dynamic vapor bubbles rising to the surface, popping, and causing a spray of tiny droplets to erupt from the droplet. This spray is called secondary atomization. Here, atomization is quantified experimentally for water droplets impinging superheated superhydrophobic surfaces. Smooth hydrophobic and superhydrophobic surfaces with varying rib and post microstructuring were explored. Each surface was placed on an aluminum heating block, and impingement events were captured with a high speed camera at 3000 fps. For consistency among tests, all events were normalized by the maximum atomization found over a range of temperatures on a smooth hydrophobic surface. An estimate of the level of atomization during an impingement event was created by quantifying the volume of fluid present in the atomization spray. Droplet diameter and Weber number were held constant, and atomization was found for a range of temperatures through the lifetime of the impinging droplet. The Leidenfrost temperature was also determined and defined to be the lowest temperature at which atomization ceases to occur. Both atomization and Leidenfrost temperature increase with decreasing pitch (distance between microstructures).
iHand: an interactive bare-hand-based augmented reality interface on commercial mobile phones
NASA Astrophysics Data System (ADS)
Choi, Junyeong; Park, Jungsik; Park, Hanhoon; Park, Jong-Il
2013-02-01
The performance of mobile phones has rapidly improved, and they are emerging as a powerful platform. In many vision-based applications, human hands play a key role in natural interaction. However, relatively little attention has been paid to the interaction between human hands and the mobile phone. Thus, we propose a vision- and hand gesture-based interface in which the user holds a mobile phone in one hand but sees the other hand's palm through a built-in camera. The virtual contents are faithfully rendered on the user's palm through palm pose estimation, and reaction with hand and finger movements is achieved that is recognized by hand shape recognition. Since the proposed interface is based on hand gestures familiar to humans and does not require any additional sensors or markers, the user can freely interact with virtual contents anytime and anywhere without any training. We demonstrate that the proposed interface works at over 15 fps on a commercial mobile phone with a 1.2-GHz dual core processor and 1 GB RAM.
NASA Astrophysics Data System (ADS)
Mitrakusuma, Windy H.; Deendarlianto, Kamal, Samsul; Indarto, Nuriyadi, M.
2016-06-01
Onset of nucleate boiling of a droplet when impacted onto hot surface was investigated. Three kinds of surfaces, normal stainless steel (NSS), stainless steel with TiO2 coating (UVN), and stainless steel with TiO2 coating and radiated by ultraviolet ray were employed to examine the effect of wettability. The droplet size was 2.4 mm diameter, and dropped under different We number. The image is generated by high speed camera with the frame speed of 1000 fps. The boiling conditions are identified as natural convection, nucleate boiling, critical heat flux, transition, and film boiling. In the present report, the discussion will be focused on the beginning of nucleate boiling on the droplet. Nucleate boiling occurs when bubbles are generated. These bubbles are probably caused by nucleation on the impurities within the liquid rather than at nucleation sites on the heated surface because the bubbles appear to be in the bulk of the liquid instead of at the liquid-solid interface. In addition, the smaller the contact angle, the fastest the boiling.
NASA Astrophysics Data System (ADS)
Limonova, Elena; Tropin, Daniil; Savelyev, Boris; Mamay, Igor; Nikolaev, Dmitry
2018-04-01
In this paper we describe stitching protocol, which allows to obtain high resolution images of long length monochromatic objects with periodic structure. This protocol can be used for long length documents or human-induced objects in satellite images of uninhabitable regions like Arctic regions. The length of such objects can reach notable values, while modern camera sensors have limited resolution and are not able to provide good enough image of the whole object for further processing, e.g. using in OCR system. The idea of the proposed method is to acquire a video stream containing full object in high resolution and use image stitching. We expect the scanned object to have straight boundaries and periodic structure, which allow us to introduce regularization to the stitching problem and adapt algorithm for limited computational power of mobile and embedded CPUs. With the help of detected boundaries and structure we estimate homography between frames and use this information to reduce complexity of stitching. We demonstrate our algorithm on mobile device and show image processing speed of 2 fps on Samsung Exynos 5422 processor
Munce, Nigel R; Mariampillai, Adrian; Standish, Beau A; Pop, Mihaela; Anderson, Kevan J; Liu, George Y; Luk, Tim; Courtney, Brian K; Wright, Graham A; Vitkin, I Alex; Yang, Victor X D
2008-04-01
A novel flexible scanning optical probe is constructed with a finely etched optical fiber strung through a platinum coil in the lumen of a dissipative polymer. The packaged probe is 2.2 mm in diameter with a rigid length of 6mm when using a ball lens or 12 mm when scanning the fiber proximal to a gradient-index (GRIN) lens. Driven by constant high voltage (1-3 kV) at low current (< 5 microA), the probe oscillates to provide wide forward-viewing angle (13 degrees and 33 degrees with ball and GRIN lens designs, respectively) and high-frame-rate (10-140 fps) operation. Motion of the probe tip is observed with a high-speed camera and compared with theory. Optical coherence tomography (OCT) imaging with the probe is demonstrated with a wavelength-swept source laser. Images of an IR card as well as in vivo Doppler OCT images of a tadpole heart are presented. This optomechanical design offers a simple, inexpensive method to obtain a high-frame-rate forward-viewing scanning probe.
A Novel Event-Based Incipient Slip Detection Using Dynamic Active-Pixel Vision Sensor (DAVIS)
Rigi, Amin
2018-01-01
In this paper, a novel approach to detect incipient slip based on the contact area between a transparent silicone medium and different objects using a neuromorphic event-based vision sensor (DAVIS) is proposed. Event-based algorithms are developed to detect incipient slip, slip, stress distribution and object vibration. Thirty-seven experiments were performed on five objects with different sizes, shapes, materials and weights to compare precision and response time of the proposed approach. The proposed approach is validated by using a high speed constitutional camera (1000 FPS). The results indicate that the sensor can detect incipient slippage with an average of 44.1 ms latency in unstructured environment for various objects. It is worth mentioning that the experiments were conducted in an uncontrolled experimental environment, therefore adding high noise levels that affected results significantly. However, eleven of the experiments had a detection latency below 10 ms which shows the capability of this method. The results are very promising and show a high potential of the sensor being used for manipulation applications especially in dynamic environments. PMID:29364190
Application of digital image correlation for long-distance bridge deflection measurement
NASA Astrophysics Data System (ADS)
Tian, Long; Pan, Bing; Cai, Youfa; Liang, Hui; Zhao, Yan
2013-06-01
Due to its advantages of non-contact, full-field and high-resolution measurement, digital image correlation (DIC) method has gained wide acceptance and found numerous applications in the field of experimental mechanics. In this paper, the application of DIC for real-time long-distance bridge deflection detection in outdoor environments is studied. Bridge deflection measurement using DIC in outdoor environments is more challenging than regular DIC measurements performed under laboratory conditions. First, much more image noise due to variations in ambient light will be presented in the images recorded in outdoor environments. Second, how to select the target area becomes a key factor because long-distance imaging results in a large field of view of the test object. Finally, the image acquisition speed of the camera must be high enough (larger than 100 fps) to capture the real-time dynamic motion of a bridge. In this work, the above challenging issues are addressed and several improvements were made to DIC method. The applicability was demonstrated by real experiments. Experimental results indicate that the DIC method has great potentials in motion measurement in various large building structures.
Air entrapment under an impacting drop
NASA Astrophysics Data System (ADS)
Thoroddsen, S. T.; Etoh, T. G.; Takehara, K.
2003-03-01
When a drop impacts on a liquid surface it entraps a small amount of air under its centre as the two liquid surfaces meet. The contact occurs along a ring enclosing a thin disk of air. We use the next-generation ultra-high-speed video camera, capable of 1 million f.p.s. (Etoh et al. 2002), to study the dynamics of this air sheet as it contracts due to surface tension, to form a bubble or, more frequently, splits into two bubbles. During the contraction of the air disk an azimuthal undulation, resembling a pearl necklace, develops along its edge. The contraction speed of the sheet is accurately described by a balance between inertia and surface tension. The average initial thickness of the air sheet decreases with higher impact Reynolds numbers, becoming less than one micron. The total volume of air entrapped depends strongly on the bottom curvature of the drop at impact. A sheet of micro-bubbles is often observed along the original interface. Oguz Prosperetti bubble rings are also observed. For low Weber numbers (We<20) a variety of other entrapment phenomena appear.
Lightning spectra at 100,000 fps
NASA Astrophysics Data System (ADS)
McHarg, M. G.; Harley, J.; Haaland, R. K.; Edens, H. E.; Stenbaek-Nielsen, H.
2016-12-01
A fundamental understanding of lightning can be inferred from the spectral emissions resulting from the leader and return stroke channel. We examine an event recorded at 00:58:07 on 19 July 2015 at Langmuir Laboratory. We recorded lightning spectra using a 100 line per mm grating in front of a Phantom V2010 camera with an 85mm Nikon lens recording at 100,000 frames per second. Coarse resolution spectra (approximately 5nm resolution) are produced from approximately 400 nm to 800 nm for each frame. Electric field data from the Langmuir Electric Field Array for the 03:19:19 event show 10 V/m changes in the electric field associated with multiple return strokes visible in the spectral data. We used the spectral data to compare temperatures at the top, middle and bottom of the lightning channel. Lightning Mapping Array data at Langmuir for the 00:58:07 event show a complex flash extending 10 km in the East-West plane and 6 km in the North-South plane. The imagery data imply that this is a bolt-from-the-blue event.
FPGA Implementation for Real-Time Background Subtraction Based on Horprasert Model
Rodriguez-Gomez, Rafael; Fernandez-Sanchez, Enrique J.; Diaz, Javier; Ros, Eduardo
2012-01-01
Background subtraction is considered the first processing stage in video surveillance systems, and consists of determining objects in movement in a scene captured by a static camera. It is an intensive task with a high computational cost. This work proposes an embedded novel architecture on FPGA which is able to extract the background on resource-limited environments and offers low degradation (produced because of the hardware-friendly model modification). In addition, the original model is extended in order to detect shadows and improve the quality of the segmentation of the moving objects. We have analyzed the resource consumption and performance in Spartan3 Xilinx FPGAs and compared to others works available on the literature, showing that the current architecture is a good trade-off in terms of accuracy, performance and resources utilization. With less than a 65% of the resources utilization of a XC3SD3400 Spartan-3A low-cost family FPGA, the system achieves a frequency of 66.5 MHz reaching 32.8 fps with resolution 1,024 × 1,024 pixels, and an estimated power consumption of 5.76 W. PMID:22368487
Frame synchronization for the Galileo code
NASA Technical Reports Server (NTRS)
Arnold, S.; Swanson, L.
1991-01-01
Results are reported on the performance of the Deep Space Network's frame synchronizer for the (15,1/4) convolutional code after Viterbi decoding. The threshold is found that optimizes the probability of acquiring true sync within four frames using a strategy that requires next frame verification.
Evaluating Afterschool Programs
ERIC Educational Resources Information Center
Little, Priscilla M.
2014-01-01
Well-implemented afterschool programs can promote a range of positive learning and developmental outcomes. However, not all research and evaluation studies have shown the benefits of participation, in part because programs and their evaluation were out of sync. This chapter provides practical guidance on how to foster that alignment between…
Weights and Measures: Out of Sync.
ERIC Educational Resources Information Center
Melone, Rudy J.
1985-01-01
Looks at the economic problems resulting from U.S. resistance to the metric system. Considers factors underpinning this resistance and reasons for industry and education to accelerate the pace of metric learning. Describes Gavilan College's pilot testing of metrics instructional materials. Lists organizations endorsing metrication. (DMM)
Trees, Jason; Snider, Joseph; Falahpour, Maryam; Guo, Nick; Lu, Kun; Johnson, Douglas C; Poizner, Howard; Liu, Thomas T
2014-01-01
Hyperscanning, an emerging technique in which data from multiple interacting subjects' brains are simultaneously recorded, has become an increasingly popular way to address complex topics, such as "theory of mind." However, most previous fMRI hyperscanning experiments have been limited to abstract social interactions (e.g. phone conversations). Our new method utilizes a virtual reality (VR) environment used for military training, Virtual Battlespace 2 (VBS2), to create realistic avatar-avatar interactions and cooperative tasks. To control the virtual avatar, subjects use a MRI compatible Playstation 3 game controller, modified by removing all extraneous metal components and replacing any necessary ones with 3D printed plastic models. Control of both scanners' operation is initiated by a VBS2 plugin to sync scanner time to the known time within the VR environment. Our modifications include:•Modification of game controller to be MRI compatible.•Design of VBS2 virtual environment for cooperative interactions.•Syncing two MRI machines for simultaneous recording.
Shahin, Antoine J; Shen, Stanley; Kerlin, Jess R
2017-01-01
We examined the relationship between tolerance for audiovisual onset asynchrony (AVOA) and the spectrotemporal fidelity of the spoken words and the speaker's mouth movements. In two experiments that only varied in the temporal order of sensory modality, visual speech leading (exp1) or lagging (exp2) acoustic speech, participants watched intact and blurred videos of a speaker uttering trisyllabic words and nonwords that were noise vocoded with 4-, 8-, 16-, and 32-channels. They judged whether the speaker's mouth movements and the speech sounds were in-sync or out-of-sync . Individuals perceived synchrony (tolerated AVOA) on more trials when the acoustic speech was more speech-like (8 channels and higher vs. 4 channels), and when visual speech was intact than blurred (exp1 only). These findings suggest that enhanced spectrotemporal fidelity of the audiovisual (AV) signal prompts the brain to widen the window of integration promoting the fusion of temporally distant AV percepts.
Flow measurement behind a pair of vertical-axis wind turbines
NASA Astrophysics Data System (ADS)
Parker, Colin M.; Hummels, Raymond; Leftwich, Megan C.
2017-11-01
The wake from a pair of vertical-axis wind turbines (VAWTs) is measured using particle imaging velocimetry (PIV). The VAWT models are mounted in a low-speed wind tunnel and driven using a motor control system. The rotation of the turbines is synced using a proportional controller that allows the turbine's rotational position to be set relative to each other. The rotation of the turbines is also synced with the PIV system for taking phase averaged results. The VAWTs are tested for both co- and counter-rotating cases over a range of relative phase offsets. Time averaged and phase averaged results are measured at the horizontal mid-plane in the near wake. The time-averaged results compare the bulk wake profiles from the pair of turbines. Phase averaged results look at the vortex interactions in the near wake of the turbines. By changing the phase relation between the turbines we can see the impact of the structure interactions in both the phase and time averaged results.
NASA Astrophysics Data System (ADS)
Da Rio, Nicola; SDSS Apogee IN-SYNC ancillary program Team
2015-01-01
I will present the results of our characterization of the dynamical status of the young stellar population in the Orion A star forming region. This is based on radial velocity measurements obtained within the SDSS-III Apogee IN-SYNC Orion Survey, which obtained high-resolution spectroscopy of ~3000 objects in the region, from the dense Orion Nebula Cluster - the prototypical nearby region of active massive star formation - to the low-density environments of the L1641 region. We find evidence for kinematic subclustering along the star forming filament, where the stellar component remains kinematically associated to the gas; in the ONC we find that the stellar population is supervirial and currently expanding. We rule out the existence of a controversial candidate foreground cluster to the south of the ONC. These results, complemented with an analysis of the spatial structure of the population, enables critical tests of theories that describe the formation and early evolution of Orion and young clusters in general.
Trees, Jason; Snider, Joseph; Falahpour, Maryam; Guo, Nick; Lu, Kun; Johnson, Douglas C.; Poizner, Howard; Liu, Thomas T.
2014-01-01
Hyperscanning, an emerging technique in which data from multiple interacting subjects’ brains are simultaneously recorded, has become an increasingly popular way to address complex topics, such as “theory of mind.” However, most previous fMRI hyperscanning experiments have been limited to abstract social interactions (e.g. phone conversations). Our new method utilizes a virtual reality (VR) environment used for military training, Virtual Battlespace 2 (VBS2), to create realistic avatar-avatar interactions and cooperative tasks. To control the virtual avatar, subjects use a MRI compatible Playstation 3 game controller, modified by removing all extraneous metal components and replacing any necessary ones with 3D printed plastic models. Control of both scanners’ operation is initiated by a VBS2 plugin to sync scanner time to the known time within the VR environment. Our modifications include:•Modification of game controller to be MRI compatible.•Design of VBS2 virtual environment for cooperative interactions.•Syncing two MRI machines for simultaneous recording. PMID:26150964
Design of a Software Configuration for Real-Time Multimedia Group Communication; HNUMTP
NASA Astrophysics Data System (ADS)
Park, Gil-Cheol
This paper designs transport protocol of multi-session/channel method for real time multimedia group telecommunication and realizes it. The special features of the designed and realized protocol are first, that it solved the sync problem which is the specific character of multimedia telecommunication by using multi-channel method protocol. Usual multimedia telecommunication is assigned one channel by each media data. This paper shortened the phenomenon that waits data for sync of receiving part by assigning more than one channel for the channel that has a lot of data per hour as video data. The problem of intermedia synchronization that happens then could be solved by sending temporal/spacial related data among data assigning extra control channel. Second, that it does integrated management for sessions. Each session is one group telecommunication unit which supports mutual working environment that is independent. Each session communicates the participants in the group independently, the session manager manages all the communication among groups and lets media sources connected with all network be operated efficiently.
Liu, Jinpeng; Horimai, Hideyoshi; Lin, Xiao; Liu, Jinyan; Huang, Yong; Tan, Xiaodi
2017-06-01
The collinear holographic data storage system (CHDSS) is a very promising storage system due to its large storage capacities and high transfer rates in the era of big data. The digital micro-mirror device (DMD) as a spatial light modulator is the key device of the CHDSS due to its high speed, high precision, and broadband working range. To improve the system stability and performance, an optimal micro-mirror tilt angle was theoretically calculated and experimentally confirmed by analyzing the relationship between the tilt angle of the micro-mirror on the DMD and the power profiles of diffraction patterns of the DMD at the Fourier plane. In addition, we proposed a novel chess board sync mark design in the data page to reduce the system bit error rate in circumstances of reduced aperture required to decrease noise and median exposure amount. It will provide practical guidance for future DMD based CHDSS development.
Combinational logic for generating gate drive signals for phase control rectifiers
NASA Technical Reports Server (NTRS)
Dolland, C. R.; Trimble, D. W. (Inventor)
1982-01-01
Control signals for phase-delay rectifiers, which require a variable firing angle that ranges from 0 deg to 180 deg, are derived from line-to-line 3-phase signals and both positive and negative firing angle control signals which are generated by comparing current command and actual current. Line-to-line phases are transformed into line-to-neutral phases and integrated to produce 90 deg phase delayed signals that are inverted to produce three cosine signals, such that for each its maximum occurs at the intersection of positive half cycles of the other two phases which are inputs to other inverters. At the same time, both positive and negative (inverted) phase sync signals are generated for each phase by comparing each with the next and producing a square wave when it is greater. Ramp, sync and firing angle controls signals are than used in combinational logic to generate the gate firing control signals SCR gate drives which fire SCR devices in a bridge circuit.
2013-01-01
Background Validation studies of secondary datasets used to characterize neighborhood food businesses generally evaluate how accurately the database represents the true situation on the ground. Depending on the research objectives, the characterization of the business environment may tolerate some inaccuracies (e.g. minor imprecisions in location or errors in business names). Furthermore, if the number of false negatives (FNs) and false positives (FPs) is balanced within a given area, one could argue that the database still provides a “fair” representation of existing resources in this area. Yet, traditional validation measures do not relax matching criteria, and treat FNs and FPs independently. Through the field validation of food businesses found in a Canadian database, this paper proposes alternative criteria for validity. Methods Field validation of the 2010 Enhanced Points of Interest (EPOI) database (DMTI Spatial®) was performed in 2011 in 12 census tracts (CTs) in Montreal, Canada. Some 410 food outlets were extracted from the database and 484 were observed in the field. First, traditional measures of sensitivity and positive predictive value (PPV) accounting for every single mismatch between the field and the database were computed. Second, relaxed measures of sensitivity and PPV that tolerate mismatches in business names or slight imprecisions in location were assessed. A novel measure of representativity that further allows for compensation between FNs and FPs within the same business category and area was proposed. Representativity was computed at CT level as ((TPs +|FPs-FNs|)/(TPs+FNs)), with TPs meaning true positives, and |FPs-FNs| being the absolute value of the difference between the number of FNs and the number of FPs within each outlet category. Results The EPOI database had a "moderate" capacity to detect an outlet present in the field (sensitivity: 54.5%) or to list only the outlets that actually existed in the field (PPV: 64.4%). Relaxed measures of sensitivity and PPV were respectively 65.5% and 77.3%. The representativity of the EPOI database was 77.7%. Conclusions The novel measure of representativity might serve as an alternative to traditional validity measures, and could be more appropriate in certain situations, depending on the nature and scale of the research question. PMID:23782570
Lessard, Chantale; Contandriopoulos, André-Pierre; Beaulieu, Marie-Dominique
2009-01-01
Background A considerable amount of resource allocation decisions take place daily at the point of the clinical encounter; especially in primary care, where 80 percent of health problems are managed. Ignoring economic evaluation evidence in individual clinical decision-making may have a broad impact on the efficiency of health services. To date, almost all studies on the use of economic evaluation in decision-making used a quantitative approach, and few investigated decision-making at the clinical level. An important question is whether economic evaluations affect clinical practice. The project is an intervention research study designed to understand the role of economic evaluation in the decision-making process of family physicians (FPs). The contributions of the project will be from the perspective of Pierre Bourdieu's sociological theory. Methods/design A qualitative research strategy is proposed. We will conduct an embedded multiple-case study design. Ten case studies will be performed. The FPs will be the unit of analysis. The sampling strategies will be directed towards theoretical generalization. The 10 selected cases will be intended to reflect a diversity of FPs. There will be two embedded units of analysis: FPs (micro-level of analysis) and field of family medicine (macro-level of analysis). The division of the determinants of practice/behaviour into two groups, corresponding to the macro-structural level and the micro-individual level, is the basis for Bourdieu's mode of analysis. The sources of data collection for the micro-level analysis will be 10 life history interviews with FPs, documents and observational evidence. The sources of data collection for the macro-level analysis will be documents and 9 open-ended, focused interviews with key informants from medical associations and academic institutions. The analytic induction approach to data analysis will be used. A list of codes will be generated based on both the original framework and new themes introduced by the participants. We will conduct within-case and cross-case analyses of the data. Discussion The question of the role of economic evaluation in FPs' decision-making is of great interest to scientists, health care practitioners, managers and policy-makers, as well as to consultants, industry, and society. It is believed that the proposed research approach will make an original contribution to the development of knowledge, both empirical and theoretical. PMID:19210787
NASA Astrophysics Data System (ADS)
Yang, Yu; Xiang, Kun; Yang, Yi-Xin; Wang, Yan-Wen; Zhang, Xin; Cui, Yangdong; Wang, Haifang; Zhu, Qing-Qing; Fan, Liqiang; Liu, Yuanfang; Cao, Aoneng
2013-10-01
A prerequisite for in vivo fluorescence imaging is the safety of fluorescent probes. Among all fluorescent probes, fluorescent proteins (FPs) might be the safest ones, which have been widely used in biological sciences at the gene level. But FPs have not been used in vivo in the purified form yet due to the instability of proteins. Here, we individually coat near-infrared (NIR) FPs (NIRFPs) with a silica nanoshell, resulting in NIRFP@silica, one of the safest and brightest NIR fluorescent nanoprobes with a quantum yield of 0.33 for in vivo imaging. The silica shell not only protects NIRFPs from denaturation and metabolic digestion, but also enhances the quantum yield and photostability of the coated NIRFPs. When injected via the tail vein, NIRFP@silica NPs can distribute all over the mouse body, and then can be efficiently eliminated through urine in 24 h, demonstrating its potential applications as a safe and robust NIR fluorescence probe for whole body imaging.A prerequisite for in vivo fluorescence imaging is the safety of fluorescent probes. Among all fluorescent probes, fluorescent proteins (FPs) might be the safest ones, which have been widely used in biological sciences at the gene level. But FPs have not been used in vivo in the purified form yet due to the instability of proteins. Here, we individually coat near-infrared (NIR) FPs (NIRFPs) with a silica nanoshell, resulting in NIRFP@silica, one of the safest and brightest NIR fluorescent nanoprobes with a quantum yield of 0.33 for in vivo imaging. The silica shell not only protects NIRFPs from denaturation and metabolic digestion, but also enhances the quantum yield and photostability of the coated NIRFPs. When injected via the tail vein, NIRFP@silica NPs can distribute all over the mouse body, and then can be efficiently eliminated through urine in 24 h, demonstrating its potential applications as a safe and robust NIR fluorescence probe for whole body imaging. Electronic supplementary information (ESI) available: A chromatogram of APTS-NIRFP, a TEM image of 40 nm NIRFP@silica, dispersion stability of NIRFP@silica, more whole body fluorescent images, serum biochemical parameters, and optical images of HE stained organ slices. See DOI: 10.1039/c3nr02508j
NASA Astrophysics Data System (ADS)
Manno, C.; Stowasser, G.; Enderlein, P.; Fielding, S.; Tarling, G. A.
2015-03-01
The northern Scotia Sea contains the largest seasonal uptake of atmospheric carbon dioxide yet measured in the Southern Ocean. This study examines one of the main routes by which this carbon fluxes to the deep ocean: through the production of faecal pellets (FPs) by the zooplankton community. Deep sediment traps were deployed at two sites with contrasting ocean productivity regimes (P3, naturally iron-fertilized, and P2, iron-limited) within the same water mass. The magnitude and seasonal pattern of particulate organic carbon (POC) and FPs in the traps was markedly different between the two sites. Maximum fluxes at P3 (22.91 mg C m-2 d-1; 2534 FP m-2 d1) were 1 order of magnitude higher than at P2 (4.01 mg C m-2 d-1; 915 FP m-2 d1, with flux at P3 exhibiting a double seasonal peak, compared to a single flatter peak at P2. The maximum contribution of FP carbon to the total amount of POC was twice as high at P3 (91%) compared to P2 (40%). The dominant FP category at P3 varied between round, ovoidal, cylindrical and tabular over the course of the year, while, at P2, ovoidal FPs were consistently dominant, always making up more than 60% of the FP assemblage. There was also a difference in the FP state between the two sites, with FPs being relatively intact at P3, while FPs were often fragmented with broken peritrophic membranes at P2. The exception was ovoidal FPs, which were relatively intact at both sites. Our observations suggest that there was a community shift from a herbivorous to an omnivorous diet from spring through to autumn at P3, while detritivores had a higher relative importance over the year at P2. Furthermore, the flux was mainly a product of the vertically migrating zooplankton community at P3, while the FP flux was more likely to be generated by deeper-dwelling zooplankton feeding on recycled material at P2. The results demonstrate that the feeding behaviour and vertical distribution of the zooplankton community plays a critical role in controlling the magnitude of carbon export to the deep ocean in this region.
NASA Astrophysics Data System (ADS)
Manno, C.; Stowasser, G.; Enderlein, P.; Fielding, S.; Tarling, G. A.
2014-11-01
The northern Scotia Sea contains the largest seasonal uptake of atmospheric carbon dioxide yet measured in the Southern Ocean. This study examines one of the main routes by which this carbon fluxes to the deep ocean, through the production of faecal pellets (FPs) by the zooplankton community. Deep sediment traps were deployed in two sites with contrasting ocean productivity regimes (P3, naturally iron-fertilized and P2, iron-limited), within the same water mass. The magnitude and seasonal pattern of particulate organic carbon (POC) and FPs in the traps was markedly different between the two sites. Maximum fluxes at P3 (22.91 mg C m-2 d-1; 2534 × 10 FP m-2 d-1) were an order of magnitude higher than at P2 (4.01 mg C m-2 d-1; 915 × 10 FP m-2 d-1), with flux at P3 exhibiting a double seasonal peak, compared to a single flatter peak at P2. The maximum contribution of FP carbon to the total amount of POC was twice as high at P3 (91%) compared to P2 (40%). The dominant FP category at P3 varied between round, ovoidal, cylindrical and tabular over the course of the year while, at P2, ovoidal FPs were consistently dominant, always making up more than 60% of the FP assemblage. There was also a difference in the FP state between the two sites, with FPs being relatively intact at P3, while FPs were often fragmented with broken peritrophic membranes at P2. The exception was ovoidal FPs, which were relatively intact at both sites. Our observations suggest that there was community shift from an herbivorous to an omnivorous diet from spring through to autumn at P3 while detritivores had a higher relative importance over the year at P2. Furthermore, the flux was mainly a product of the vertically migrating zooplankton community at P3 while the FP flux was more likely to be generated by deeper-dwelling zooplankton feeding on recycled material at P2. The results demonstrate that the feeding behavior and vertical distribution of the zooplankton community plays a critical role in controlling the magnitude of carbon export to the deep ocean in this region.
ERIC Educational Resources Information Center
Dogan, Sebnem Koldas; Ay, Saime; Oztuna, Derya; Aytur, Yesim Kurtais; Evcik, Deniz
2010-01-01
This study was planned to investigate the utility of the vertical Faces Pain Scale (FPS) in the assessment of pain in stroke patients using the shoulder pain model and to assess its utility in the Turkish patient population. The secondary aim was to analyze the association of FPS with the quality of life and depression in the study population.…
Reduction of lymph tissue false positives in pulmonary embolism detection
NASA Astrophysics Data System (ADS)
Ghanem, Bernard; Liang, Jianming; Bi, Jinbo; Salganicoff, Marcos; Krishnan, Arun
2008-03-01
Pulmonary embolism (PE) is a serious medical condition, characterized by the partial/complete blockage of an artery within the lungs. We have previously developed a fast yet effective approach for computer aided detection of PE in computed topographic pulmonary angiography (CTPA),1 which is capable of detecting both acute and chronic PEs, achieving a benchmark performance of 78% sensitivity at 4 false positives (FPs) per volume. By reviewing the FPs generated by this system, we found the most dominant type of FP, roughly one third of all FPs, to be lymph/connective tissue. In this paper, we propose a novel approach that specifically aims at reducing this FP type. Our idea is to explicitly exploit the anatomical context configuration of PE and lymph tissue in the lungs: a lymph FP connects to the airway and is located outside the artery, while a true PE should not connect to the airway and must be inside the artery. To realize this idea, given a detected candidate (i.e. a cluster of suspicious voxels), we compute a set of contextual features, including its distance to the airway based on local distance transform and its relative position to the artery based on fast tensor voting and Hessian "vesselness" scores. Our tests on unseen cases show that these features can reduce the lymph FPs by 59%, while improving the overall sensitivity by 3.4%.
Preliminary Design and Evaluation of Portable Electronic Flight Progress Strips
NASA Technical Reports Server (NTRS)
Doble, Nathan A.; Hansman, R. John
2002-01-01
There has been growing interest in using electronic alternatives to the paper Flight Progress Strip (FPS) for air traffic control. However, most research has been centered on radar-based control environments, and has not considered the unique operational needs of the airport air traffic control tower. Based on an analysis of the human factors issues for control tower Decision Support Tool (DST) interfaces, a requirement has been identified for an interaction mechanism which replicates the advantages of the paper FPS (e.g., head-up operation, portability) but also enables input and output with DSTs. An approach has been developed which uses a Portable Electronic FPS that has attributes of both a paper strip and an electronic strip. The prototype flight strip system uses Personal Digital Assistants (PDAs) to replace individual paper strips in addition to a central management interface which is displayed on a desktop computer. Each PDA is connected to the management interface via a wireless local area network. The Portable Electronic FPSs replicate the core functionality of paper flight strips and have additional features which provide a heads-up interface to a DST. A departure DST is used as a motivating example. The central management interface is used for aircraft scheduling and sequencing and provides an overview of airport departure operations. This paper will present the design of the Portable Electronic FPS system as well as preliminary evaluation results.
Funahashi, Aki; Itakura, Takao; Hassanin Abeer, A I; Komatsu, Masaharu; Hayashi, Seiichi; Kaminishi, Yoshio
2017-03-01
In this study, the localization of fluorescent protein (FP) was characterized in the muscles of four species and two subspecies of eels Anguilla anguilla, A. australis, A. bicolor bicolor (b.), A. bicolor pacifica (p.) and A. mossambica in addition to the previously reported A. japonica. The open reading frame of each eel FP was 417 bp encoding 139 amino acid residues. The deduced amino acid sequences among the four species and two subspecies exhibited 91.4-100% identity, and belonged to the fatty-acid-binding protein (FABP) family. The gene structure of eel FPs in A. japonica, A. anguilla, A. australis, A. bicolor b., A. bicolor p. and A. mossambica have four exons and three introns, and were common to that of FABP family. The apo eel FPs expressed by Escherichia coli with recombinant eel FP genes were analysed for the fluorescent properties in the presence of bilirubin. The excitation and emission spectra of holo eel FPs had the maximum wavelengths of 490-496 and 527-530 nm, respectively. The holo eel FPs indicated that the fluorescent intensities were stronger in A. japonica and A. bicolor than in A. mossambica, A. australis and A. anguilla. The comparison of amino acid sequences revealed two common substitutions in A. mossambica, A. australis and A. anguilla with weak fluorescent intensity.
Community size and organization of practice predict family physician recertification success.
Schulte, Bradley M; Mannino, David M; Royal, Kenneth D; Brown, Sabrina L; Peterson, Lars E; Puffer, James C
2014-01-01
Health disparities exist between rural and urban areas. Rural physicians may lack sufficient medical knowledge, which may lead to poor quality of care. Therefore, we sought to determine whether medical knowledge differed between family physicians (FPs) practicing in rural areas compared with those practicing in metropolitan areas. We studied 8361 FPs who took the American Board of Family Medicine maintenance of certification (MOC) examination in 2009. Data sources were examination results and data from a demographic survey of practice structure and activities, completed as part of the examination application process. FPs' location of practice was categorized as either rural or metropolitan using a moderate and conservative definition based on reported community size. Univariate statistics assessed differences in FP characteristics between rural and metropolitan areas. Logistic regression analyses determined the adjusted relationship between rural status and the odds of passing the MOC examination. Metropolitan FPs were less likely than their rural counterparts to pass the MOC examination using both the moderate (odds ratio, 0.67; 95% confidence interval, 0.54-0.83) and conservative (odds ratio, 0.56; 95% confidence interval, 0.42-0.74) definitions. Physicians in solo practice were less likely to pass the examination than physicians in group practice. Rural physicians were more likely to pass the MOC examination, suggesting that rural health disparities do not result from a lack of provider knowledge.
Psychosocial diagnoses occurring after patients present with fatigue.
MacKean, Peter Reagh; Stewart, Moira; Maddocks, Heather L
2016-08-01
To discover the frequency of psychosocial and other diagnoses occurring at the end of a visit when patients present to their FPs with concerns about fatigue. Cross-sectional study of patient-FP encounters for fatigue. Ten FP practices in southwestern Ontario. A total of 259 encounters involving 167 patients presenting to their FPs between March 1, 2006, and June 30, 2010, with concerns about fatigue. The frequency of psychological and social diagnoses made at the end of visits, and whether diagnoses were made by FPs at the end of the visits versus whether the code for fatigue remained. The associations between patient age, sex, fatigue presenting with other symptoms, or the presence of previous chronic conditions and the outcomes was tested. Psychosocial diagnoses were made 23.9% of the time. Among psychosocial diagnoses made, depressive disorder and anxiety disorder or anxiety state were diagnosed more often in women (P = .048). Slightly less than 30% of the time, the cause of patients' fatigue remained undiagnosed at the end of the encounter. A diagnosis was made more often in men. Causes of fatigue frequently remain undiagnosed; however, when there is a diagnosis, psychosocial diagnoses are common. Therefore, it would be appropriate for FPs to screen for psychosocial issues when their patients present with fatigue, unless some other diagnosis is evident. Depression and anxiety could be considered particularly among female patients with fatigue. Copyright© the College of Family Physicians of Canada.
Minimal domain of bacterial phytochrome required for chromophore binding and fluorescence
NASA Astrophysics Data System (ADS)
Rumyantsev, Konstantin A.; Shcherbakova, Daria M.; Zakharova, Natalia I.; Emelyanov, Alexander V.; Turoverov, Konstantin K.; Verkhusha, Vladislav V.
2015-12-01
Fluorescent proteins (FP) are used to study various biological processes. Recently, a series of near-infrared (NIR) FPs based on bacterial phytochromes was developed. Finding ways to improve NIR FPs is becoming progressively important. By applying rational design and molecular evolution we have engineered R. palustris bacterial phytochrome into a single-domain NIR FP of 19.6 kDa, termed GAF-FP, which is 2-fold and 1.4-fold smaller than bacterial phytochrome-based NIR FPs and GFP-like proteins, respectively. Engineering of GAF-FP involved a substitution of 15% of its amino acids and a deletion of the knot structure. GAF-FP covalently binds two tetrapyrrole chromophores, biliverdin (BV) and phycocyanobilin (PCB). With the BV chromophore GAF-FP absorbs at 635 nm and fluoresces at 670 nm. With the PCB chromophore GAF-FP becomes blue-shifted and absorbs at 625 nm and fluoresces at 657 nm. The GAF-FP structure has a high tolerance to small peptide insertions. The small size of GAF-FP and its additional absorbance band in the violet range has allowed for designing a chimeric protein with Renilla luciferase. The chimera exhibits efficient non-radiative energy transfer from luciferase to GAF-FP, resulting in NIR bioluminescence. This study opens the way for engineering of small NIR FPs and NIR luciferases from bacterial phytochromes.
Preparing for the Inclusive Classroom: Changing Teachers' Attitudes and Knowledge
ERIC Educational Resources Information Center
Srivastava, Meenakshi; de Boer, Anke A.; Pijl, Sip Jan
2017-01-01
India's educational policy on inclusive education for students with disabilities is in sync with general global developments. Especially in the last couple of years there have been significant legislative achievements towards this endeavour. However, the implementation of inclusive education remains elusive. Besides this, teachers' preparedness…
RUN LENGTH SYNCHRONIZATION TECHNIQUES
An important aspect of digital communications is the problem of determining efficient methods for acquiring block synchronization . In this paper we...utilizes an N-digit sync sequence as prefix to the data blocks. The results of this study show that this technique is a practical method for acquiring block synchronization .
ERIC Educational Resources Information Center
Wallace, Carolyn S.; Coffey, Debra
2016-01-01
The "Next Generation Science Standards'" ("NGSS") eight scientific and engineering practices invite teachers to develop key investigative skills while addressing important disciplinary science ideas (NGSS Lead States 2013). The "NGSS" can also provide direct links to "Common Core English Language Arts…
Rudin, Stephen; Kuhls, Andrew T.; Yadava, Girijesh K.; Josan, Gaurav C.; Wu, Ye; Chityala, Ravishankar N.; Rangwala, Hussain S.; Ciprian Ionita, N.; Hoffmann, Kenneth R.; Bednarek, Daniel R.
2011-01-01
New cone-beam computed tomographic (CBCT) mammography system designs are presented where the detectors provide high spatial resolution, high sensitivity, low noise, wide dynamic range, negligible lag and high frame rates similar to features required for high performance fluoroscopy detectors. The x-ray detectors consist of a phosphor coupled by a fiber-optic taper to either a high gain image light amplifier (LA) then CCD camera or to an electron multiplying CCD. When a square-array of such detectors is used, a field-of-view (FOV) to 20 × 20 cm can be obtained where the images have pixel-resolution of 100 µm or better. To achieve practical CBCT mammography scan-times, 30 fps may be acquired with quantum limited (noise free) performance below 0.2 µR detector exposure per frame. Because of the flexible voltage controlled gain of the LA’s and EMCCDs, large detector dynamic range is also achievable. Features of such detector systems with arrays of either generation 2 (Gen 2) or 3 (Gen 3) LAs optically coupled to CCD cameras or arrays of EMCCDs coupled directly are compared. Quantum accounting analysis is done for a variety of such designs where either the lowest number of information carriers off the LA photo-cathode or electrons released in the EMCCDs per x-ray absorbed in the phosphor are large enough to imply no quantum sink for the design. These new LA- or EMCCD-based systems could lead to vastly improved CBCT mammography, ROI-CT, or fluoroscopy performance compared to systems using flat panels. PMID:21297904
NASA Astrophysics Data System (ADS)
Rudin, Stephen; Kuhls, Andrew T.; Yadava, Girijesh K.; Josan, Gaurav C.; Wu, Ye; Chityala, Ravishankar N.; Rangwala, Hussain S.; Ionita, N. Ciprian; Hoffmann, Kenneth R.; Bednarek, Daniel R.
2006-03-01
New cone-beam computed tomographic (CBCT) mammography system designs are presented where the detectors provide high spatial resolution, high sensitivity, low noise, wide dynamic range, negligible lag and high frame rates similar to features required for high performance fluoroscopy detectors. The x-ray detectors consist of a phosphor coupled by a fiber-optic taper to either a high gain image light amplifier (LA) then CCD camera or to an electron multiplying CCD. When a square-array of such detectors is used, a field-of-view (FOV) to 20 x 20 cm can be obtained where the images have pixel-resolution of 100 μm or better. To achieve practical CBCT mammography scan-times, 30 fps may be acquired with quantum limited (noise free) performance below 0.2 μR detector exposure per frame. Because of the flexible voltage controlled gain of the LA's and EMCCDs, large detector dynamic range is also achievable. Features of such detector systems with arrays of either generation 2 (Gen 2) or 3 (Gen 3) LAs optically coupled to CCD cameras or arrays of EMCCDs coupled directly are compared. Quantum accounting analysis is done for a variety of such designs where either the lowest number of information carriers off the LA photo-cathode or electrons released in the EMCCDs per x-ray absorbed in the phosphor are large enough to imply no quantum sink for the design. These new LA- or EMCCD-based systems could lead to vastly improved CBCT mammography, ROI-CT, or fluoroscopy performance compared to systems using flat panels.
Video Recording With a GoPro in Hand and Upper Extremity Surgery.
Vara, Alexander D; Wu, John; Shin, Alexander Y; Sobol, Gregory; Wiater, Brett
2016-10-01
Video recordings of surgical procedures are an excellent tool for presentations, analyzing self-performance, illustrating publications, and educating surgeons and patients. Recording the surgeon's perspective with high-resolution video in the operating room or clinic has become readily available and advances in software improve the ease of editing these videos. A GoPro HERO 4 Silver or Black was mounted on a head strap and worn over the surgical scrub cap, above the loupes of the operating surgeon. Five live surgical cases were recorded with the camera. The videos were uploaded to a computer and subsequently edited with iMovie or the GoPro software. The optimal settings for both the Silver and Black editions, when operating room lights are used, were determined to be a narrow view, 1080p, 60 frames per second (fps), spot meter on, protune on with auto white balance, exposure compensation at -0.5, and without a polarizing lens. When the operating room lights were not used, it was determined that the standard settings for a GoPro camera were ideal for positioning and editing (4K, 15 frames per second, spot meter and protune off). The GoPro HERO 4 provides high-quality, the surgeon perspective, and a cost-effective video recording of upper extremity surgical procedures. Challenges include finding the optimal settings for each surgical procedure and the length of recording due to battery life limitations. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vidovič, L.; Milanič, M.; Majaron, B.
2013-09-01
Pulsed photothermal radiometry (PPTR) allows for noninvasive determination of the laser-induced temperature depth profile in strongly scattering samples, including human skin. In a recent experimental study, we have demonstrated that such information can be used to derive rather accurate predictions of the maximal safe radiant exposure on an individual patient basis. This has important implications for efficacy and safety of several laser applications in dermatology and aesthetic surgery, which are often compromised by risk of adverse side effects (e.g., scarring, and dyspigmentation) resulting from nonselective absorption of strong laser light in epidermal melanin. In this study, the differences between the individual maximal safe radiant exposure values as predicted from PPTR temperature depth profiling performed using a commercial mid-IR thermal camera (as used to acquire the original patient data) and our customized PPTR setup are analyzed. To this end, the latter has been used to acquire 17 PPTR records from three healthy volunteers, using 1 ms laser irradiation at 532 nm and a signal sampling rate of 20 000 . The laser-induced temperature profiles are reconstructed first from the intact PPTR signals, and then by binning the data to imitate the lower sampling rate of the IR camera (1000 fps). Using either the initial temperature profile in a dedicated numerical model of heat transfer or protein denaturation dynamics, the predicted levels of epidermal thermal damage and the corresponding are compared. A similar analysis is performed also with regard to the differences between noise characteristics of the two PPTR setups.
The accessory parotid gland and facial process of the parotid gland on computed tomography
Ahn, Dongbin; Yeo, Chang Ki; Han, Soon Yong
2017-01-01
The purpose of this study was to determine the incidence of an anterior extension of the parotid gland, such as an accessory parotid gland (APG) or facial process (FP) and to evaluate its characteristics on computed tomography (CT) scans. We reviewed CT scans of 1,600 parotid glands from 800 patients. An APG on CT was defined as a soft-tissue mass of the same density as the main parotid gland, located at the anterior part of the main parotid gland, and completely separate from the main parotid gland. An FP was defined as a lobe of the parotid gland protruding anteriorly over the anterior edge of the ramus of the mandible on CT and showing continuity with the main gland. The overall incidence rates and characteristics of APGs and FPs were evaluated according to age, sex, and side. The incidence rates of APGs and FPs were 10.2% (163/1,600) and 28.3% (452/1,600), respectively. The mean size of an APG was 15.8 mm × 5.0 mm and the mean distance from the main parotid gland was 10.5 mm. The FP reached anteriorly between the anterior edge of the mandibular ramus and the anterior border of the masseter muscle in 405 (89.6%) cases, while it extended over the anterior border of the masseter muscle in 47 (10.4%) cases. The incidence rates of APGs and FPs decreased and increased, respectively, with increasing age, showing significant linear correlations. However, the incidence of an anterior extension of the parotid gland (either an APG or an FP) was similar across all age groups. The present study showed that CT might be helpful in identifying anterior extensions of the parotid gland including APGs and FPs. The anatomical information gained from this study contributes to a better understanding of APGs and FPs and how their incidence changes with age. PMID:28915265
Neural strategies for selective attention distinguish fast-action video game players.
Krishnan, Lavanya; Kang, Albert; Sperling, George; Srinivasan, Ramesh
2013-01-01
We investigated the psychophysical and neurophysiological differences between fast-action video game players (specifically first person shooter players, FPS) and non-action players (role-playing game players, RPG) in a visual search task. We measured both successful detections (hit rates) and steady-state visually evoked EEG potentials (SSVEPs). Search difficulty was varied along two dimensions: number of adjacent attended and ignored regions (1, 2 and 4), and presentation rate of novel search arrays (3, 8.6 and 20 Hz). Hit rates decreased with increasing presentation rates and number of regions, with the FPS players performing on average better than the RPG players. The largest differences in hit rate, between groups, occurred when four regions were simultaneously attended. We computed signal-to-noise ratio (SNR) of SSVEPs and used partial least squares regression to model hit rates, SNRs and their relationship at 3 Hz and 8.6 Hz. The following are the most significant results: RPG players' parietal responses to the attended 8.6 Hz flicker were predictive of hit rate and were positively correlated with it, indicating attentional signal enhancement. FPS players' parietal responses to the ignored 3 Hz flicker were predictive of hit rate and were positively correlated with it, indicating distractor suppression. Consistent with these parietal responses, RPG players' frontal responses to the attended 8.6 Hz flicker, increased as task difficulty increased with number of regions; FPS players' frontal responses to the ignored 3 Hz flicker increased with number of regions. Thus the FPS players appear to employ an active suppression mechanism to deploy selective attention simultaneously to multiple interleaved regions, while RPG primarily use signal enhancement. These results suggest that fast-action gaming can affect neural strategies and the corresponding networks underlying attention, presumably by training mechanisms of distractor suppression.
Beat-to-beat control of human optokinetic nystagmus slow phase durations
Furman, Joseph M.
2016-01-01
This study provides the first clear evidence that the generation of optokinetic nystagmus fast phases (FPs) is a decision process that is influenced by performance of a concurrent disjunctive reaction time task (DRT). Ten subjects performed an auditory DRT during constant velocity optokinetic stimulation. Eye movements were measured in three dimensions with a magnetic search coil. Slow phase (SP) durations were defined as the interval between FPs. There were three main findings. Firstly, human optokinetic nystagmus SP durations are consistent with a model of a Gaussian basic interval generator (a type of biological clock), such that FPs can be triggered randomly at the end of a clock cycle (mean duration: 200–250 ms). Kolmogorov-Smirnov tests could not reject the modeled cumulative distribution for any data trials. Secondly, the FP need not be triggered at the end of a clock cycle, so that individual SP durations represent single or multiple clock cycles. Thirdly, the probability of generating a FP at the end of each interval generator cycle decreases significantly during performance of a DRT. These findings indicate that the alternation between SPs and FPs of optokinetic nystagmus is not purely reflexive. Rather, the triggering of the next FP is postponed more frequently if a recently presented DRT trial is pending action when the timing cycle expires. Hence, optokinetic nystagmus FPs show dual-task interference in a manner usually attributed to voluntary movements, including saccades. NEW & NOTEWORTHY This study provides the first clear evidence that the generation of optokinetic nystagmus (OKN) fast phases is a decision process that is influenced by performance of a concurrent disjunctive reaction time task (DRT). The slow phase (SP) durations are consistent with a Gaussian basic interval generator and multiple interval SP durations occur more frequently in the presence of the DRT. Hence, OKN shows dual-task interference in a manner observed in voluntary movements, such as saccades. PMID:27760815
Technical note: real-time web-based wireless visual guidance system for radiotherapy.
Lee, Danny; Kim, Siyong; Palta, Jatinder R; Kim, Taeho
2017-06-01
Describe a Web-based wireless visual guidance system that mitigates issues associated with hard-wired audio-visual aided patient interactive motion management systems that are cumbersome to use in routine clinical practice. Web-based wireless visual display duplicates an existing visual display of a respiratory-motion management system for visual guidance. The visual display of the existing system is sent to legacy Web clients over a private wireless network, thereby allowing a wireless setting for real-time visual guidance. In this study, active breathing coordinator (ABC) trace was used as an input for visual display, which captured and transmitted to Web clients. Virtual reality goggles require two (left and right eye view) images for visual display. We investigated the performance of Web-based wireless visual guidance by quantifying (1) the network latency of visual displays between an ABC computer display and Web clients of a laptop, an iPad mini 2 and an iPhone 6, and (2) the frame rate of visual display on the Web clients in frames per second (fps). The network latency of visual display between the ABC computer and Web clients was about 100 ms and the frame rate was 14.0 fps (laptop), 9.2 fps (iPad mini 2) and 11.2 fps (iPhone 6). In addition, visual display for virtual reality goggles was successfully shown on the iPhone 6 with 100 ms and 11.2 fps. A high network security was maintained by utilizing the private network configuration. This study demonstrated that a Web-based wireless visual guidance can be a promising technique for clinical motion management systems, which require real-time visual display of their outputs. Based on the results of this study, our approach has the potential to reduce clutter associated with wired-systems, reduce space requirements, and extend the use of medical devices from static usage to interactive and dynamic usage in a radiotherapy treatment vault.
Park, Steven I.; Shenoi, Jaideep; Frayo, Shani M.; Hamlin, Donald K.; Lin, Yukang; Wilbur, D. Scott; Stayton, Patrick S.; Orgun, Nural; Hylarides, Mark; Buchegger, Franz; Kenoyer, Aimee L.; Axtman, Amanda; Gopal, Ajay K.; Green, Damian J.; Pagel, John M.; Press, Oliver W.
2011-01-01
Purpose Pretargeted radioimmunotherapy (PRIT) using streptavidin (SAv)-biotin technology can deliver higher therapeutic doses of radioactivity to tumors than conventional RIT. However, “endogenous” biotin can interfere with the effectiveness of this approach by blocking binding of radiolabeled biotin to SAv. We engineered a series of SAv FPs that down-modulate the affinity of SAv for biotin, while retaining high avidity for divalent DOTA-bis-biotin to circumvent this problem. Experimental Design The single-chain variable region gene of the murine 1F5 anti-CD20 antibody was fused to the wild-type (WT) SAv gene and to mutant SAv genes, Y43A-SAv and S45A-SAv. FPs were expressed, purified and compared in studies using athymic mice bearing Ramos lymphoma xenografts. Results Biodistribution studies demonstrated delivery of more radioactivity to tumors of mice pretargeted with mutant SAv FPs followed by 111In-DOTA-bis-biotin (6.2 ± 1.7 % of the injected dose per gram [%ID/gm] of tumor 24 hours after Y43A-SAv FP and 5.6 ± 2.2 %ID/g with S45A-SAv FP) than in mice on normal diets pretargeted with WT-SAv FP (2.5 ± 1.6 %ID/g; p = 0.01). These superior biodistributions translated into superior anti-tumor efficacy in mice treated with mutant FPs and 90Y-DOTA-bis-biotin (tumor volumes after 11 days: 237 ± 66 mm3 with Y43A-SAv, 543 ± 320 mm3 with S45A-SAv, 1129 ± 322 mm3 with WT-SAv and 1435 ± 212 mm3 with control FP [p < 0.0001]). Conclusions Genetically engineered mutant-SAv FPs and bis-biotin reagents provide an attractive alternative to current SAv-biotin PRIT methods in settings where endogenous biotin levels are high. PMID:21976541
Park, Steven I; Shenoi, Jaideep; Frayo, Shani M; Hamlin, Donald K; Lin, Yukang; Wilbur, D Scott; Stayton, Patrick S; Orgun, Nural; Hylarides, Mark; Buchegger, Franz; Kenoyer, Aimee L; Axtman, Amanda; Gopal, Ajay K; Green, Damian J; Pagel, John M; Press, Oliver W
2011-12-01
Pretargeted radioimmunotherapy (PRIT) using streptavidin (SAv)-biotin technology can deliver higher therapeutic doses of radioactivity to tumors than conventional RIT. However, "endogenous" biotin can interfere with the effectiveness of this approach by blocking binding of radiolabeled biotin to SAv. We engineered a series of SAv FPs that downmodulate the affinity of SAv for biotin, while retaining high avidity for divalent DOTA-bis-biotin to circumvent this problem. The single-chain variable region gene of the murine 1F5 anti-CD20 antibody was fused to the wild-type (WT) SAv gene and to mutant SAv genes, Y43A-SAv and S45A-SAv. FPs were expressed, purified, and compared in studies using athymic mice bearing Ramos lymphoma xenografts. Biodistribution studies showed delivery of more radioactivity to tumors of mice pretargeted with mutant SAv FPs followed by (111)In-DOTA-bis-biotin [6.2 ± 1.7% of the injected dose per gram (%ID/gm) of tumor 24 hours after Y43A-SAv FP and 5.6 ± 2.2%ID/g with S45A-SAv FP] than in mice on normal diets pretargeted with WT-SAv FP (2.5 ± 1.6%ID/g; P = 0.01). These superior biodistributions translated into superior antitumor efficacy in mice treated with mutant FPs and (90)Y-DOTA-bis-biotin [tumor volumes after 11 days: 237 ± 66 mm(3) with Y43A-SAv, 543 ± 320 mm(3) with S45A-SAv, 1129 ± 322 mm(3) with WT-SAv, and 1435 ± 212 mm(3) with control FP (P < 0.0001)]. Genetically engineered mutant-SAv FPs and bis-biotin reagents provide an attractive alternative to current SAv-biotin PRIT methods in settings where endogenous biotin levels are high. ©2011 AACR.
Gerzeli, Simone; Rognoni, Carla; Quaglini, Silvana; Cavallo, Maria Caterina; Cremonesi, Giovanni; Papi, Alberto
2012-04-01
Asthma is a chronic disease characterized by acute symptomatic episodes with variable severity and duration. Pharmacological asthma management aims to achieve and maintain control without side effects, thus improving quality of life and reducing the economic impact. Recently, a clinical trial showed the non-inferiority of beclomethasone/formoterol (BDP/F) versus fluticasone propionate/salmeterol (FP/S) in adults with moderate to severe persistent asthma. However, this study did not provide evidence on costs and did not quantify quality-of-life parameters. The objective of the present study was to assess the cost effectiveness and cost utility of BDP/F versus FP/S in patients with moderate to severe asthma from the perspective of the Italian National Health Service (NHS). A Markov model (MM) was used, with five health states for the different levels of asthma control: successful control, sub-optimal control, outpatient-managed exacerbation, inpatient-managed exacerbation, and death. Model data were derived from the ICAT SE study and from expert panels. Three outcomes were considered: time spent in successful control state, costs and quality-adjusted life-years (QALYs). The model shows that BDP/F treatment led to a slight increase of weeks in successful control compared with FP/S, with a lower cost. The probabilistic sensitivity analysis highlights that in 64% and 68% of the Monte Carlo simulations, BDP/F outperformed FP/S in terms of weeks in successful control and QALYs. Considering the expected cost of the two strategies, in 90% of simulations BDP/F was the least expensive choice. In particular, BDP/F was cost saving as compared with FP/S in about 63% and 59% of simulations as shown by the cost-utility and cost-effectiveness analysis, respectively. Overall, from the Italian NHS perspective, BDP/F treatment is associated with a reduction in cost and offers a slight increase of effectiveness in terms of weeks spent in successful control and QALYs. © 2012 Adis Data Information BV. All rights reserved.
Beat-to-beat control of human optokinetic nystagmus slow phase durations.
Balaban, Carey D; Furman, Joseph M
2017-01-01
This study provides the first clear evidence that the generation of optokinetic nystagmus fast phases (FPs) is a decision process that is influenced by performance of a concurrent disjunctive reaction time task (DRT). Ten subjects performed an auditory DRT during constant velocity optokinetic stimulation. Eye movements were measured in three dimensions with a magnetic search coil. Slow phase (SP) durations were defined as the interval between FPs. There were three main findings. Firstly, human optokinetic nystagmus SP durations are consistent with a model of a Gaussian basic interval generator (a type of biological clock), such that FPs can be triggered randomly at the end of a clock cycle (mean duration: 200-250 ms). Kolmogorov-Smirnov tests could not reject the modeled cumulative distribution for any data trials. Secondly, the FP need not be triggered at the end of a clock cycle, so that individual SP durations represent single or multiple clock cycles. Thirdly, the probability of generating a FP at the end of each interval generator cycle decreases significantly during performance of a DRT. These findings indicate that the alternation between SPs and FPs of optokinetic nystagmus is not purely reflexive. Rather, the triggering of the next FP is postponed more frequently if a recently presented DRT trial is pending action when the timing cycle expires. Hence, optokinetic nystagmus FPs show dual-task interference in a manner usually attributed to voluntary movements, including saccades. This study provides the first clear evidence that the generation of optokinetic nystagmus (OKN) fast phases is a decision process that is influenced by performance of a concurrent disjunctive reaction time task (DRT). The slow phase (SP) durations are consistent with a Gaussian basic interval generator and multiple interval SP durations occur more frequently in the presence of the DRT. Hence, OKN shows dual-task interference in a manner observed in voluntary movements, such as saccades. Copyright © 2017 the American Physiological Society.
Clarkson, Matthew J; Zombori, Gergely; Thompson, Steve; Totz, Johannes; Song, Yi; Espak, Miklos; Johnsen, Stian; Hawkes, David; Ourselin, Sébastien
2015-03-01
To perform research in image-guided interventions, researchers need a wide variety of software components, and assembling these components into a flexible and reliable system can be a challenging task. In this paper, the NifTK software platform is presented. A key focus has been high-performance streaming of stereo laparoscopic video data, ultrasound data and tracking data simultaneously. A new messaging library called NiftyLink is introduced that uses the OpenIGTLink protocol and provides the user with easy-to-use asynchronous two-way messaging, high reliability and comprehensive error reporting. A small suite of applications called NiftyGuide has been developed, containing lightweight applications for grabbing data, currently from position trackers and ultrasound scanners. These applications use NiftyLink to stream data into NiftyIGI, which is a workstation-based application, built on top of MITK, for visualisation and user interaction. Design decisions, performance characteristics and initial applications are described in detail. NiftyLink was tested for latency when transmitting images, tracking data, and interleaved imaging and tracking data. NiftyLink can transmit tracking data at 1,024 frames per second (fps) with latency of 0.31 milliseconds, and 512 KB images with latency of 6.06 milliseconds at 32 fps. NiftyIGI was tested, receiving stereo high-definition laparoscopic video at 30 fps, tracking data from 4 rigid bodies at 20-30 fps and ultrasound data at 20 fps with rendering refresh rates between 2 and 20 Hz with no loss of user interaction. These packages form part of the NifTK platform and have proven to be successful in a variety of image-guided surgery projects. Code and documentation for the NifTK platform are available from http://www.niftk.org . NiftyLink is provided open-source under a BSD license and available from http://github.com/NifTK/NiftyLink . The code for this paper is tagged IJCARS-2014.
Soler, Jean Karl
2003-03-27
In Malta, sickness certificates are needed from the first day of illness, and are issued by family physicians (FPs) either employed by the government primary health care system, self-employed in private practice, or employed by an employer for this purpose alone. The latter system, when applied by the employer, is compulsory. In order to contribute to the debate on the role of the FP in this context, electronic data collected by a group of company-employed FPs was used to study the phenomenon of sickness certification. This database is a complete record of the selected employees' sick leave certification during the study period. Data collected by company-employed FPs from a defined population was used: all employees of selected Maltese companies served by a group of FPs. The database included episode-based data from home visits over three years (01/01/1997 - 31/12/1999), by 9 company-appointed FPs regarding 421 employees of five companies. 3015 episodes of sickness absenteeism, with an average duration of 2.9 days, were documented. Employees who did intensive manual work had relatively higher rates. Furthermore, a relatively higher incidence of work injury, sprains and strains, anxiety and depression and low back pain as found in manual workers, and in male workers. This trend was shown to be statistically significant. The frequency of sick-leave certification in Malta is comparable to that in other European countries, but the average duration of certificates is much less than reported in other studies that generally did not include data on short-term illness and certification. This has important implications on future research in the field. A number of common disorders were found to be significantly more prevalent causes of sickness certification in manual workers, amongst them anxiety and depression.
Diversity and Evolution of Coral Fluorescent Proteins
Alieva, Naila O.; Konzen, Karen A.; Field, Steven F.; Meleshkevitch, Ella A.; Hunt, Marguerite E.; Beltran-Ramirez, Victor; Miller, David J.; Wiedenmann, Jörg; Salih, Anya; Matz, Mikhail V.
2008-01-01
GFP-like fluorescent proteins (FPs) are the key color determinants in reef-building corals (class Anthozoa, order Scleractinia) and are of considerable interest as potential genetically encoded fluorescent labels. Here we report 40 additional members of the GFP family from corals. There are three major paralogous lineages of coral FPs. One of them is retained in all sampled coral families and is responsible for the non-fluorescent purple-blue color, while each of the other two evolved a full complement of typical coral fluorescent colors (cyan, green, and red) and underwent sorting between coral groups. Among the newly cloned proteins are a “chromo-red” color type from Echinopora forskaliana (family Faviidae) and pink chromoprotein from Stylophora pistillata (Pocilloporidae), both evolving independently from the rest of coral chromoproteins. There are several cyan FPs that possess a novel kind of excitation spectrum indicating a neutral chromophore ground state, for which the residue E167 is responsible (numeration according to GFP from A. victoria). The chromoprotein from Acropora millepora is an unusual blue instead of purple, which is due to two mutations: S64C and S183T. We applied a novel probabilistic sampling approach to recreate the common ancestor of all coral FPs as well as the more derived common ancestor of three main fluorescent colors of the Faviina suborder. Both proteins were green such as found elsewhere outside class Anthozoa. Interestingly, a substantial fraction of the all-coral ancestral protein had a chromohore apparently locked in a non-fluorescent neutral state, which may reflect the transitional stage that enabled rapid color diversification early in the history of coral FPs. Our results highlight the extent of convergent or parallel evolution of the color diversity in corals, provide the foundation for experimental studies of evolutionary processes that led to color diversification, and enable a comparative analysis of structural determinants of different colors. PMID:18648549
Impact of family medicine clerkships in undergraduate medical education: a systematic review
Turkeshi, Eralda; Michels, Nele R; Hendrickx, Kristin; Remmen, Roy
2015-01-01
Objective Synthesise evidence about the impact of family medicine/general practice (FM) clerkships on undergraduate medical students, teaching general/family practitioners (FPs) and/or their patients. Data sources Medline, ERIC, PsycINFO, EMBASE and Web of Knowledge searched from 21 November to 17 December 2013. Primary, empirical, quantitative or qualitative studies, since 1990, with abstracts included. No country restrictions. Full text languages: English, French, Spanish, German, Dutch or Italian. Review methods Independent selection and data extraction by two authors using predefined data extraction fields, including Kirkpatrick’s levels for educational intervention outcomes, study quality indicators and Best Evidence Medical Education (BEME) strength of findings’ grades. Descriptive narrative synthesis applied. Results Sixty-four included articles: impact on students (48), teaching FPs (12) and patients (8). Sample sizes: 16-1095 students, 3-146 FPs and 94-2550 patients. Twenty-six studies evaluated at Kirkpatrick level 1, 26 at level 2 and 6 at level 3. Only one study achieved BEME’s grade 5. The majority was assessed as grade 4 (27) and 3 (33). Students reported satisfaction with content and process of teaching as well as learning in FM clerkships. They enhanced previous learning, and provided unique learning on dealing with common acute and chronic conditions, health maintenance, disease prevention, communication and problem-solving skills. Students’ attitudes towards FM were improved, but new or enhanced interest in FM careers did not persist without change after graduation. Teaching FPs reported increased job satisfaction and stimulation for professional development, but also increased workload and less productivity, depending on the setting. Overall, student’s presence and participation did not have a negative impact on patients. Conclusions Research quality on the impact of FM clerkships is still limited, yet across different settings and countries, positive impact is reported on students, FPs and patients. Future studies should involve different stakeholders, medical schools and countries, and use standardised and validated evaluation tools. PMID:26243553
Manufacturing Methods and Technology Engineering for Tape Chip Carrier.
1981-08-01
equipment and fixtures were used in the manufacturer of the Sync Counter hybrid microcircuit. o Continuous Tape Plater - Model No. STP, Microplate ...Headquarters 001 Commander ATTN: Ray L. Gilbert Naval Ocean Systems Center 608 Independence Ave., SW ATTN: Dr. W. D. McKee, Jr. Washington, DC 20546 Code
When Worlds Collide: An Augmented Reality Check
ERIC Educational Resources Information Center
Villano, Matt
2008-01-01
The technology is simple: Mobile technologies such as handheld computers and global positioning systems work in sync to create an alternate, hybrid world that mixes virtual characters with the actual physical environment. The result is a digital simulation that offers powerful game-playing opportunities and allows students to become more engaged…
NASA Technical Reports Server (NTRS)
1972-01-01
The assembly drawings of the receiver unit are presented for the data compression/error correction digital test system. Equipment specifications are given for the various receiver parts, including the TV input buffer register, delta demodulator, TV sync generator, memory devices, and data storage devices.
ERIC Educational Resources Information Center
Scribner-MacLean, Michelle; Nikonchuk, Andrew; Kaplo, Patrick; Wall, Michael
2006-01-01
Science educators are often among the first to use emerging technologies in the classroom and laboratory. For the technologically savvy science teacher, the handheld computer is a terrific tool. A handheld computer is a portable electronic device that helps organize (via calendars, contact lists, to-do lists) and integrate electronic data…
Age of Creative Insecurity: Student-Centered Learning. Historical Paper 7
ERIC Educational Resources Information Center
Martell, Charles
2015-01-01
Trapped by inflexible mechanisms, many institutions are unable to adapt smoothly to the changing expectations and needs of their clients. Our educational system is particularly out-of-sync. Student-centered teaching--participative education--through unstructuring is one method for encouraging a flexible, creative, classroom environment. However,…
ERIC Educational Resources Information Center
Van Orsdel, Lee C.; Born, Kathleen
2007-01-01
In a year filled with drama and hyperbole, the serials marketplace churned toward a future whose shape is the subject of fierce debate. Forecasts from commercial publishers touting collapse and disaster seemed oddly out of sync with the profits they enjoyed--around 25 percent on average. Nevertheless, in a market where prices continued to rise and…
E-Governance in Education: Pursuit of Education Excellence
ERIC Educational Resources Information Center
Natarajan, Sundarapandiyan
2015-01-01
This article aims to explore today's educational challenges, being technologically supreme, the primary focus on education is to bring out the outcome and value based education to the community. Electronic Governance (e- Governance) focuses not only the technological infrastructure and getting the learning environment sync is the major challenge.…
DOT National Transportation Integrated Search
2012-07-01
The FHWAs Every Day Counts (EDC) initiative identifies adaptive signal control as a tool for local agencies to deploy : innovation. In an effort to achieve the goals of the EDC initiative, the traffic sections of the Colorado Department of : Trans...
ERIC Educational Resources Information Center
Finkel, Ed
2017-01-01
Community college presidents and board members come and go. But a major driver of the continued success of two-year colleges is how fruitfully the relationships between CEOs and their boards evolve over time--from the onboarding process when a president first takes the helm to the "outboarding" process that starts with them giving…
panMetaDocs and DataSync - providing a convenient way to share and publish research data
NASA Astrophysics Data System (ADS)
Ulbricht, D.; Klump, J. F.
2013-12-01
In recent years research institutions, geological surveys and funding organizations started to build infrastructures to facilitate the re-use of research data from previous work. At present, several intermeshed activities are coordinated to make data systems of the earth sciences interoperable and recorded data discoverable. Driven by governmental authorities, ISO19115/19139 emerged as metadata standards for discovery of data and services. Established metadata transport protocols like OAI-PMH and OGC-CSW are used to disseminate metadata to data portals. With the persistent identifiers like DOI and IGSN research data and corresponding physical samples can be given unambiguous names and thus become citable. In summary, these activities focus primarily on 'ready to give away'-data, already stored in an institutional repository and described with appropriate metadata. Many datasets are not 'born' in this state but are produced in small and federated research projects. To make access and reuse of these 'small data' easier, these data should be centrally stored and version controlled from the very beginning of activities. We developed DataSync [1] as supplemental application to the panMetaDocs [2] data exchange platform as a data management tool for small science projects. DataSync is a JAVA-application that runs on a local computer and synchronizes directory trees into an eSciDoc-repository [3] by creating eSciDoc-objects via eSciDocs' REST API. DataSync can be installed on multiple computers and is in this way able to synchronize files of a research team over the internet. XML Metadata can be added as separate files that are managed together with data files as versioned eSciDoc-objects. A project-customized instance of panMetaDocs is provided to show a web-based overview of the previously uploaded file collection and to allow further annotation with metadata inside the eSciDoc-repository. PanMetaDocs is a PHP based web application to assist the creation of metadata in any XML-based metadata schema. To reduce manual entries of metadata to a minimum and make use of contextual information in a project setting, metadata fields can be populated with static or dynamic content. Access rights can be defined to control visibility and access to stored objects. Notifications about recently updated datasets are available by RSS and e-mail and the entire inventory can be harvested via OAI-PMH. panMetaDocs is optimized to be harvested by panFMP [4]. panMetaDocs is able to mint dataset DOIs though DataCite and uses eSciDocs' REST API to transfer eSciDoc-objects from a non-public 'pending'-status to the published status 'released', which makes data and metadata of the published object available worldwide through the internet. The application scenario presented here shows the adoption of open source applications to data sharing and publication of data. An eSciDoc-repository is used as storage for data and metadata. DataSync serves as a file ingester and distributor, whereas panMetaDocs' main function is to annotate the dataset files with metadata to make them ready for publication and sharing with your own team, or with the scientific community.
1977-04-01
Conductivity ...... . .i 6 Relief Map of Conductivity ......... i9 7a conductivity versus Axial Position with Radial Position a a Parater...concentrations ii. pressure iii. temperature iv. velocity v. snie, number and velocity distribuions of the liquid particlas (if any are to be considered) I vi...Number = 1 vi. J• velocity = 8644 fps; Edge velocity = 10 fps vii. Jet temperature = 21160 K; Edge temperature = 278*K Also, at the exit piane, the
PScan 1.0: flexible software framework for polygon based multiphoton microscopy
NASA Astrophysics Data System (ADS)
Li, Yongxiao; Lee, Woei Ming
2016-12-01
Multiphoton laser scanning microscopes exhibit highly localized nonlinear optical excitation and are powerful instruments for in-vivo deep tissue imaging. Customized multiphoton microscopy has a significantly superior performance for in-vivo imaging because of precise control over the scanning and detection system. To date, there have been several flexible software platforms catered to custom built microscopy systems i.e. ScanImage, HelioScan, MicroManager, that perform at imaging speeds of 30-100fps. In this paper, we describe a flexible software framework for high speed imaging systems capable of operating from 5 fps to 1600 fps. The software is based on the MATLAB image processing toolbox. It has the capability to communicate directly with a high performing imaging card (Matrox Solios eA/XA), thus retaining high speed acquisition. The program is also designed to communicate with LabVIEW and Fiji for instrument control and image processing. Pscan 1.0 can handle high imaging rates and contains sufficient flexibility for users to adapt to their high speed imaging systems.
A Funny Thing Happened on the Way to the Forum: Physics and Society in the new millenium
NASA Astrophysics Data System (ADS)
Zwicker, Andrew
2012-03-01
I joined the Executive Committee of FPS in 2001, served for two consecutive terms as Secretary/Treasurer (2001 - 2006), and then one 3-year cycle as Vice Chair-Chair-Past Chair (2007 - 2009). During this first decade of the new millenium, FPS made significant changes to how we carried out elections (fully electronic) and gradually reduced the paper editions of the newsletter from four to two (with two electronic) to, finally, fully electronic. The changes, with the resultant decrease in costs associated with printing and mailing, gave the Forum the financial freedom to expand its activities. Ironically, the last paper edition of our newsletter was also, perhaps, our most infamous as we found ourself no longer simply reporting on the climate change controversy, but a part of the story. In this talk, I will reflect upon my experiences during this period and what it might imply for the next 40 years of FPS.
A study of entropy/clarity of genetic sequences using metric spaces and fuzzy sets.
Georgiou, D N; Karakasidis, T E; Nieto, Juan J; Torres, A
2010-11-07
The study of genetic sequences is of great importance in biology and medicine. Sequence analysis and taxonomy are two major fields of application of bioinformatics. In the present paper we extend the notion of entropy and clarity to the use of different metrics and apply them in the case of the Fuzzy Polynuclotide Space (FPS). Applications of these notions on selected polynucleotides and complete genomes both in the I(12×k) space, but also using their representation in FPS are presented. Our results show that the values of fuzzy entropy/clarity are indicative of the degree of complexity necessary for the description of the polynucleotides in the FPS, although in the latter case the interpretation is slightly different than in the case of the I(12×k) hypercube. Fuzzy entropy/clarity along with the use of appropriate metrics can contribute to sequence analysis and taxonomy. Copyright © 2010 Elsevier Ltd. All rights reserved.
Fluorescent proteins for FRET microscopy: monitoring protein interactions in living cells.
Day, Richard N; Davidson, Michael W
2012-05-01
The discovery and engineering of novel fluorescent proteins (FPs) from diverse organisms is yielding fluorophores with exceptional characteristics for live-cell imaging. In particular, the development of FPs for fluorescence (or Förster) resonance energy transfer (FRET) microscopy is providing important tools for monitoring dynamic protein interactions inside living cells. The increased interest in FRET microscopy has driven the development of many different methods to measure FRET. However, the interpretation of FRET measurements is complicated by several factors including the high fluorescence background, the potential for photoconversion artifacts and the relatively low dynamic range afforded by this technique. Here, we describe the advantages and disadvantages of four methods commonly used in FRET microscopy. We then discuss the selection of FPs for the different FRET methods, identifying the most useful FP candidates for FRET microscopy. The recent success in expanding the FP color palette offers the opportunity to explore new FRET pairs. Copyright © 2012 WILEY Periodicals, Inc.
Chu, Jun; Haynes, Russell D; Corbel, Stéphane Y; Li, Pengpeng; González-González, Emilio; Burg, John S; Ataie, Niloufar J; Lam, Amy J; Cranfill, Paula J; Baird, Michelle A; Davidson, Michael W; Ng, Ho-Leung; Garcia, K Christopher; Contag, Christopher H; Shen, Kang; Blau, Helen M; Lin, Michael Z
2014-01-01
A method for non-invasive visualization of genetically labelled cells in animal disease models with micron-level resolution would greatly facilitate development of cell-based therapies. Imaging of fluorescent proteins (FPs) using red excitation light in the “optical window” above 600 nm is one potential method for visualizing implanted cells. However, previous efforts to engineer FPs with peak excitation beyond 600 nm have resulted in undesirable reductions in brightness. Here we report three new red-excitable monomeric FPs obtained by structure-guided mutagenesis of mNeptune, previously the brightest monomeric FP when excited beyond 600 nm. Two of these, mNeptune2 and mNeptune2.5, demonstrate improved maturation and brighter fluorescence, while the third, mCardinal, has a red-shifted excitation spectrum without reduction in brightness. We show that mCardinal can be used to non-invasively and longitudinally visualize the differentiation of myoblasts and stem cells into myocytes in living mice with high anatomical detail. PMID:24633408
Study of fusion product effects in field-reversed mirrors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Driemeyer, D.E.
1980-01-01
The effect of fusion products (fps) on Field-Reversed Mirror (FRM) reactor concepts has been evaluated through the development of two new computer models. The first code (MCFRM) treats fps as test particles in a fixed background plasma, which is represented as a fluid. MCFRM includes a Monte Carlo treatment of Coulomb scattering and thus provides an accurate treatment of fp behavior even at lower energies where pitch-angle scattering becomes important. The second code (FRMOD) is a steady-state, globally averaged, two-fluid (ion and electron), point model of the FRM plasma that incorporates fp heating and ash buildup values which are consistentmore » with the MCFRM calculations. These codes have been used extensively in the development of an advanced-fuel FRM reactor design (SAFFIRE). A Catalyzed-D version of the plant is also discussed along with an investigation of the steady-state energy distribution of fps in the FRM. User guides for the two computer codes are also included.« less
NASA Astrophysics Data System (ADS)
Gaudin, Damien; Cimarelli, Corrado; Behnke, Sonja; Cigala, Valeria; Edens, Harald; McNutt, Stefen; Smith, Cassandra; Thomas, Ronald; Van Eaton, Alexa
2017-04-01
Volcanic lightning is being increasingly studied, due to its great potential for the detection and monitoring of ash plumes. Indeed, it is observed in a large number of ash-rich volcanic eruptions and it produces electromagnetic waves that can be detected remotely in all weather conditions. Electrical discharges in volcanic plume can also significantly change the structural, chemical and reactivity properties of the erupted material. Although electrical discharges are detected in various regions of the plume, those happening at the onset of an explosion are of particular relevance for the early warning and the study of volcanic jet dynamics. In order to better constrain the electrical activity of young volcanic plumes, we deployed at Sakurajima (Japan) in 2015 a multiparametric set-up including: i) a lightning mapping array (LMA) of 10 VHF antennas recording the electromagnetic waves produced by lightning at a sample rate of 25 Msps; ii) a visible-light high speed camera (5000 frames per second, 0.5 m pixel size, 300 m field of view) shooting short movies (approx. duration 1 s) at different stages of the plume evolution, showing the location of discharges in relation to the plume; and iii) a thermal camera (25 fps, 1.5 m pixel size, 800 m field of view) continuously recording the plume and allowing the estimation of its main source parameters (volume, rise velocity, mass eruption rate). The complementarity of these three setups is demonstrated by comparing and aggregating the data at various stages of the plume development. In the earliest stages, the high speed camera spots discrete small discharges, that appear on the LMA data as peaks superimposed to the continuous radio frequency (CRF) signal. At later stages, flashes happen less frequently and increase in length. The correspondence between high speed camera and LMA data allows to define a direct correlation between the length of the flash and the intensity of the electromagnetic signal. Such correlation is used to estimate the evolution of the total discharges within a volcanic plume, while the superimposition of thermal and high speed videos allows to contextualize the flashes location in the scope of the plume features and dynamics.
Li, Bin E.; Ernst, Patricia
2015-01-01
MLL1, located on human chromosome 11, is disrupted in distinct recurrent chromosomal translocations in several leukemia subsets. Studying the MLL1 gene and its oncogenic variants has provided a paradigm for understanding cancer initiation and maintenance through aberrant epigenetic gene regulation. Here we review the historical development of model systems to recapitulate oncogenic MLL1-rearrangement (MLL-r) alleles encoding mixed-lineage leukemia fusion proteins (MLL-FPs) or internal gene rearrangement products. These largely mouse and human cell/xenograft systems have been generated and used to understand how MLL-r alleles affect diverse pathways to result in a highly penetrant, drug-resistant leukemia. The particular features of the animal models influenced the conclusions of mechanisms of transformation. We discuss significant downstream enablers, inhibitors, effectors, and collaborators of MLL-r leukemia, including molecules that directly interact with MLL-FPs and endogenous mixed-lineage leukemia protein, direct target genes of MLL-FPs, and other pathways that have proven to be influential in supporting or suppressing the leukemogenic activity of MLL-FPs. The use of animal models has been complemented with patient sample, genome-wide analyses to delineate the important genomic and epigenomic changes that occur in distinct subsets of MLL-r leukemia. Collectively, these studies have resulted in rapid progress toward developing new strategies for targeting MLL-r leukemia and general cell-biological principles that may broadly inform targeting aberrant epigenetic regulators in other cancers. PMID:25264566
Kloefkorn, Heidi E.; Pettengill, Travis R.; Turner, Sara M. F.; Streeter, Kristi A.; Gonzalez-Rothi, Elisa J.; Fuller, David D.; Allen, Kyle D.
2016-01-01
While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns. PMID:27554674
Michopoulos, Vasiliki; Rothbaum, Alex O; Corwin, Elizabeth; Bradley, Bekh; Ressler, Kerry J; Jovanovic, Tanja
2015-08-01
While female sex is a robust risk factor for posttraumatic stress disorder (PTSD), pregnant women are an understudied population in regards to PTSD symptom expression profiles. Because circulating hormones during pregnancy affect emotionality, we assessed whether pregnant women would have increased expression of the intermediate phenotypes of hyperarousal and fear-potentiated startle (FPS) compared to non-pregnant women. We examined PTSD symptom profiles in pregnant (n = 207) and non-pregnant women (n = 370). In a second study, FPS responses were assessed in 15 pregnant and 24 non-pregnant women. All participants were recruited from the obstetrics and gynecology clinic at a public hospital serving a primarily African-American, low socioeconomic status, inner-city population. Our results indicate that overall PTSD symptoms were not different between the groups of women. However, pregnant women reported being more hypervigilant (p = 0.036) than non-pregnant women. In addition, pregnant women showed increased FPS to a safety signal compared to non-pregnant women (p = 0.024). FPS to a safety signal in pregnant women was significantly correlated with PTSD hyperarousal symptoms (r = 0.731, p < 0.001). Furthermore, discrimination between danger and safety signals was present in non-pregnant women (p = 0.008), but not in pregnant women (p = 0.895). Together, these data suggest that pregnant women show clinical and psychophysiological hyperarousal compared to non-pregnant women, and support screening for PTSD and assessment of PTSD risk in pregnant women.
Sadeh, Naomi; Verona, Edelyn
2012-01-01
A long-standing debate is the extent to which psychopathy is characterized by a fundamental deficit in attention or emotion. We tested the hypothesis that the interplay of emotional and attentional systems is critical for understanding processing deficits in psychopathy. Sixty-three offenders were assessed using the Psychopathy Checklist: Screening Version. Event-related brain potentials (ERPs) and fear-potentiated startle (FPS) were collected while participants viewed pictures selected to disentangle an existing confound between perceptual complexity and emotional content in the pictures typically used to study fear deficits in psychopathy. As predicted, picture complexity moderated emotional processing deficits. Specifically, the affective-interpersonal features of psychopathy were associated with greater allocation of attentional resources to processing emotional stimuli at initial perception (visual N1) but only when picture stimuli were visually-complex. Despite this, results for the late positive potential indicated that emotional pictures were less attentionally engaging and held less motivational significance for individuals high in affective-interpersonal traits. This deficient negative emotional processing was observed later in their reduced defensive fear reactivity (FPS) to high-complexity unpleasant pictures. In contrast, the impulsive-antisocial features of psychopathy were associated with decreased sensitivity to picture complexity (visual N1) and unrelated to emotional processing as assessed by ERP and FPS. These findings are the first to demonstrate that picture complexity moderates FPS deficits and implicate the interplay of attention and emotional systems as deficient in psychopathy. PMID:22187225
NASA Astrophysics Data System (ADS)
Stoltzfus, Caleb; Mikhailov, Alexandr; Rebane, Aleksander
2017-02-01
Fluorescence induced by 1wo-photon absorption (2PA) and three-photon absorption (3PA) is becoming an increasingly important tool for deep-tissue microscopy, especially in conjunction with genetically-encoded functional probes such as fluorescent proteins (FPs). Unfortunately, the efficacy of the multi-photon excitation of FPs is notoriously low, and because relations between a biological fluorophore's nonlinear-optical properties and its molecular structure are inherently complex, there are no practical avenues available that would allow boosting the performance of current FPs. Here we describe a novel method, where we apply directed evolution to optimize the 2PA properties of EGFP. Key to the success of this approach consists in high-throughput screening of mutants that would allow selection of variants with promising 2PA and 3PA properties in a broad near-IR excitation range of wavelength. For this purpose, we construct and test a wide field-of-view (FOV), femtosecond imaging system that we then use to quantify the multi-photon excited fluorescence in the 550- 1600 nm range of tens of thousands of E. coli colonies expressing randomly mutated FPs in a standard 10 cm diameter Petri dish configuration. We present a quantitative analysis of different factors that are currently limiting the maximum throughput of the femtosecond multi-photon screening techniques and also report on quantitative measurement of absolute 2PA and 3PA cross sections spectra.
Kloefkorn, Heidi E; Pettengill, Travis R; Turner, Sara M F; Streeter, Kristi A; Gonzalez-Rothi, Elisa J; Fuller, David D; Allen, Kyle D
2017-03-01
While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns.
A comparison of frame synchronization methods. [Deep Space Network
NASA Technical Reports Server (NTRS)
Swanson, L.
1982-01-01
Different methods are considered for frame synchronization of a concatenated block code/Viterbi link. Synchronization after Viterbi decoding, synchronization before Viterbi decoding based on hard-quantized channel symbols are all compared. For each scheme, the probability under certain conditions of true detection of sync within four 10,000 bit frames is tabulated.
Exergaming: Syncing Physical Activity and Learning
ERIC Educational Resources Information Center
Hicks, Lisa; Higgins, John
2010-01-01
This article discusses exergaming, a groundbreaking type of video game which is creating a revolution in physical education. Exergaming combines physical activity and video gaming to create an enjoyable and appealing way for students to be physically active. An extremely popular choice in this genre is the music video/dance rhythm game (MVDG). One…
Understanding Our Gifted. Volume 5, Issues 1-6, September 1992-August 1993.
ERIC Educational Resources Information Center
Silverman, Linda Kreger, Ed.
1993-01-01
The six issues of this newsletter have the following themes: (1) home schooling, (2) promising practices, (3) parent advocacy, (4) the young gifted child, (5) "being out of sync," and (6) philosophy of giftedness. Major articles include the following: "Homeschooling for Gifted Primary Students" (Patricia Linehan); "Learning to Fly: A Home…
Teachers Little Helper: Multi-Math-Coach
ERIC Educational Resources Information Center
Ebner, Martin; Schön, Martin; Taraghi, Behnam; Steyre, Michael
2013-01-01
Individual learning is out of sync with the elements of a curricula and the daily program of a teacher. At a time when multidigit multiplication methods are taught, many children are not perfectly performing the basic multiplication table. Teachers organize settings for learning and they usually have no time to give an individual feedback to every…
2011-06-01
Sync Matrix Assessing J/ADOCS (Fires) TBMCS (ATO) Executing Monitoring (SA) C2 Strategy Objectives • Provide Expanded Mission Management...Computers, and Intelligence T&E Test and Evaluation PMW150 Program Warfare Office Command and Control TBMCS Theater Battle Management Core System POR
Noise-sustained synchronization between electrically coupled FitzHugh-Nagumo networks
NASA Astrophysics Data System (ADS)
Cascallares, Guadalupe; Sánchez, Alejandro D.; dell'Erba, Matías G.; Izús, Gonzalo G.
2015-09-01
We investigate the capability of electrical synapses to transmit the noise-sustained network activity from one network to another. The particular setup we consider is two identical rings with excitable FitzHugh-Nagumo cell dynamics and nearest-neighbor antiphase intra-ring coupling, electrically coupled between corresponding nodes. The whole system is submitted to independent local additive Gaussian white noises with common intensity η, but only one ring is externally forced by a global adiabatic subthreshold harmonic signal. We then seek conditions for a particular noise level to promote synchronized stable firing patterns. By running numerical integrations with increasing η, we observe the excitation activity to become spatiotemporally self-organized, until η is so strong that spoils sync between networks for a given value of the electric coupling strength. By means of a four-cell model and calculating the stationary probability distribution, we obtain a (signal-dependent) non-equilibrium potential landscape which explains qualitatively the observed regimes, and whose barrier heights give a good estimate of the optimal noise intensity for the sync between networks.
Serino, Silvia; Morganti, Francesca; Colombo, Desirée; Pedroli, Elisa; Cipresso, Pietro; Riva, Giuseppe
2018-06-01
A growing body of evidence pointed out that a decline in effectively using spatial reference frames for categorizing information occurs both in normal and pathological aging. Moreover, it is also known that executive deficits primarily characterize the cognitive profile of older individuals. Acknowledging this literature, the current study was aimed to specifically disentangle the contribution of the cognitive abilities related to the use of spatial reference frames to executive functioning in both healthy and pathological aging. 48 healthy elderly individuals and 52 elderly suffering from probable Alzheimer's Disease (AD) took part in the study. We exploited the potentiality of Virtual Reality to specifically measure the abilities in retrieving and syncing between different spatial reference frames, and then we administrated different neuropsychological tests for evaluating executive functions. Our results indicated that allocentric functions contributed significantly to the planning abilities, while syncing abilities influenced the attentional ones. The findings were discussed in terms of previous literature exploring relationships between cognitive deficits in the first phase of AD.
Link Performance Analysis and monitoring - A unified approach to divergent requirements
NASA Astrophysics Data System (ADS)
Thom, G. A.
Link Performance Analysis and real-time monitoring are generally covered by a wide range of equipment. Bit Error Rate testers provide digital link performance measurements but are not useful during real-time data flows. Real-time performance monitors utilize the fixed overhead content but vary widely from format to format. Link quality information is also present from signal reconstruction equipment in the form of receiver AGC, bit synchronizer AGC, and bit synchronizer soft decision level outputs, but no general approach to utilizing this information exists. This paper presents an approach to link tests, real-time data quality monitoring, and results presentation that utilizes a set of general purpose modules in a flexible architectural environment. The system operates over a wide range of bit rates (up to 150 Mbs) and employs several measurement techniques, including P/N code errors or fixed PCM format errors, derived real-time BER from frame sync errors, and Data Quality Analysis derived by counting significant sync status changes. The architecture performs with a minimum of elements in place to permit a phased update of the user's unit in accordance with his needs.
NASA Astrophysics Data System (ADS)
Jaehnig, Karl; Bird, Jonathan C.; Stassun, Keivan G.; Da Rio, Nicola; Tan, Jonathan C.; Cotaar, Michiel; Somers, Garrett
2017-12-01
We study the occurrence of spectroscopic binaries in young star-forming regions using the INfrared Spectroscopy of Young Nebulous Clusters (IN-SYNC) survey, carried out in SDSS-III with the APOGEE spectrograph. Multi-epoch observations of thousands of low-mass stars in Orion A, NGC 2264, NGC 1333, IC 348, and the Pleiades have been carried out, yielding H-band spectra with a nominal resolution of R = 22,500 for sources with H < 12 mag. Radial velocity precisions of ˜0.3 {km} {{{s}}}-1 were achieved, which we use to identify radial velocity variations indicative of undetected companions. We use Monte Carlo simulations to assess the types of spectroscopic binaries to which we are sensitive, finding sensitivity to binaries with orbital periods ≲ {10}3.5 days, for stars with 2500 {{K}}≤slant {T}{eff}≤slant 6000 {{K}} and v \\sin i < 100 {km} {{{s}}}-1. Using Bayesian inference, we find evidence for a decline in the spectroscopic binary fraction, by a factor of 3-4, from the age of our pre-main-sequence (PMS) sample to the Pleiades age . The significance of this decline is weakened if spot-induced radial-velocity jitter is strong in the sample, and is only marginally significant when comparing any one of the PMS clusters against the Pleiades. However, the same decline in both sense and magnitude is found for each of the five PMS clusters, and the decline reaches a statistical significance of greater than 95% confidence when considering the PMS clusters jointly. Our results suggest that dynamical processes disrupt the widest spectroscopic binaries ({P}{orb}≈ {10}3{--}{10}4 days) as clusters age, indicating that this occurs early in the stars’ evolution, while they still reside within their nascent clusters.
A study of polymerization shrinkage kinetics using digital image correlation.
Lau, Andrew; Li, Jianying; Heo, Young Cheul; Fok, Alex
2015-04-01
To investigate the polymerization shrinkage kinetics of dental resin composites by measuring in real time the full-field shrinkage strain using a novel technique based on digital image correlation (DIC). Polymerization shrinkage in resin composite specimens (Filtek LS and Z100) was measured as a function of time and position. The main experimental setup included a CCD camera and an external shutter inversely synchronized to that of the camera. The specimens (2 mm × 4 mm × 5 mm) were irradiated for 40s at 1200 mW/cm(2), while alternating image acquisition and obstruction of the curing light occurred at 15 fps. The acquired images were processed using proprietary software to obtain the full-field strain maps as a function of time. Z100 showed a higher final shrinkage value and rate of development than LS. The final volumetric shrinkage for Z100 and LS were 1.99% and 1.19%, respectively. The shrinkage behavior followed an established shrinkage strain kinetics model. The corresponding characteristic time and reaction order exponent for LS and Z100 were calculated to be approximately 23s and 0.84, and 14s and 0.7, respectively, at a distance of 1.0mm from the irradiated surface, the position where maximum shrinkage strain occurred. Thermal expansion from the exothermic reaction could have affected the accuracy of these parameters. The new DIC method using an inversely synchronized shutter provided realtime, full-field results that could aid in assessing the shrinkage strain kinetics of dental resin composites as a function of specimen depth. It could also help determine the optimal curing modes for dental resin composites. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Balsalobre-Fernández, Carlos; Tejero-González, Carlos M; del Campo-Vecino, Juan; Bavaresco, Nicolás
2014-02-01
Flight time is the most accurate and frequently used variable when assessing the height of vertical jumps. The purpose of this study was to analyze the validity and reliability of an alternative method (i.e., the HSC-Kinovea method) for measuring the flight time and height of vertical jumping using a low-cost high-speed Casio Exilim FH-25 camera (HSC). To this end, 25 subjects performed a total of 125 vertical jumps on an infrared (IR) platform while simultaneously being recorded with a HSC at 240 fps. Subsequently, 2 observers with no experience in video analysis analyzed the 125 videos independently using the open-license Kinovea 0.8.15 software. The flight times obtained were then converted into vertical jump heights, and the intraclass correlation coefficient (ICC), Bland-Altman plot, and Pearson correlation coefficient were calculated for those variables. The results showed a perfect correlation agreement (ICC = 1, p < 0.0001) between both observers' measurements of flight time and jump height and a highly reliable agreement (ICC = 0.997, p < 0.0001) between the observers' measurements of flight time and jump height using the HSC-Kinovea method and those obtained using the IR system, thus explaining 99.5% (p < 0.0001) of the differences (shared variance) obtained using the IR platform. As a result, besides requiring no previous experience in the use of this technology, the HSC-Kinovea method can be considered to provide similarly valid and reliable measurements of flight time and vertical jump height as more expensive equipment (i.e., IR). As such, coaches from many sports could use the HSC-Kinovea method to measure the flight time and height of their athlete's vertical jumps.
Deshazer, Garron; Prakash, Punit; Merck, Derek; Haemmerich, Dieter
2017-02-01
For computational models of microwave ablation (MWA), knowledge of the antenna design is necessary, but the proprietary design of clinical applicators is often unknown. We characterised the specific absorption rate (SAR) during MWA experimentally and compared to a multi-physics simulation. An infrared (IR) camera was used to measure SAR during MWA within a split ex vivo liver model. Perseon Medical's short-tip (ST) or long-tip (LT) MWA antenna were placed on top of a tissue sample (n = 6), and microwave power (15 W) was applied for 6 min, while intermittently interrupting power. Tissue surface temperature was recorded via IR camera (3.3 fps, 320 × 240 resolution). SAR was calculated intermittently based on temperature slope before and after power interruption. Temperature and SAR data were compared to simulation results. Experimentally measured SAR changed considerably once tissue temperatures exceeded 100 °C, contrary to simulation results. The ablation zone diameters were 1.28 cm and 1.30 ± 0.03 cm (transverse), and 2.10 cm and 2.66 ± -0.22 cm (axial), for simulation and experiment, respectively. The average difference in temperature between the simulation and experiment were 5.6 °C (ST) and 6.2 °C (LT). Dice coefficients for 1000 W/kg SAR iso-contour were 0.74 ± 0.01 (ST) and 0.77 (± 0.03) (LT), suggesting good agreement of SAR contours. We experimentally demonstrated changes in SAR during MWA ablation, which were not present in simulation, suggesting inaccuracies in dielectric properties. The measured SAR may be used in simplified computer simulations to predict tissue temperature when the antenna geometry is unknown.
NASA Astrophysics Data System (ADS)
de Jesus, V. L. B.; Haubrichs, C.; de Oliveira, A. L.; Sasaki, D. G. G.
2018-03-01
In the present work, we develop a low-cost and simple experiment to visualise Fourier’s synthesis using a short, soft, and light plastic coiled spring oscillating in a horizontal plane, and a basic camera (120 fps). It is shown that the spring obeys a linear wave differential equation, as gravitational influence is neglected. A nonlinear criterion is evaluated to determine if magnitudes of the parameters in the initial conditions satisfy the linear wave equation. Our setup promotes some desirable characteristics that make Fourier’s synthesis experiments feasible, visual, and enlightening: (i) it requires few, common, and cheap resources, and the experiment can be carried out even in a high-school laboratory; (ii) since the spring’s tension is small (∼1 N, on average), the frequencies of normal modes are low (close to 2 Hz), and therefore, it is possible to record the oscillations just with the camera and extract a considerable number of position and time data in just one cycle; (iii) when the video is loaded in the Tracker free software, it can be reproduced in slow motion. Since the frequencies involved are low, an interesting and instructive temporal sequence of images of the spring displaying the typical trapezoidal shape appears clearly; (iv) the tools associated with the Tracker software tools can yield the relevant oscillation parameters, such as the damping constant, amplitudes, frequencies, and phases; and (v) it is possible to carry out superposition of a snapshot of the spring in Tracker at any time, and to draw the related Fourier synthesis graphs. The visual match between the shape of the spring and the theoretical graph is remarkable, and can be enhanced by adding the damping term.
Scott, A D; Boubertakh, R; Birch, M J; Miquel, M E
2012-11-01
The objective of this study was to demonstrate soft palate MRI at 1.5 and 3 T with high temporal resolution on clinical scanners. Six volunteers were imaged while speaking, using both four real-time steady-state free-precession (SSFP) sequences at 3 T and four balanced SSFP (bSSFP) at 1.5 T. Temporal resolution was 9-20 frames s(-1) (fps), spatial resolution 1.6 × 1.6 × 10.0-2.7 × 2.7 × 10.0 mm(3). Simultaneous audio was recorded. Signal-to-noise ratio (SNR), palate thickness and image quality score (1-4, non-diagnostic-excellent) were evaluated. SNR was higher at 3 T than 1.5 T in the relaxed palate (nasal breathing position) and reduced in the elevated palate at 3 T, but not 1.5 T. Image quality was not significantly different between field strengths or sequences (p=NS). At 3 T, 40% acquisitions scored 2 and 56% scored 3. Most 1.5 T acquisitions scored 1 (19%) or 4 (46%). Image quality was more dependent on subject or field than sequence. SNR in static images was highest with 1.9 × 1.9 × 10.0 mm(3) resolution (10 fps) and measured palate thickness was similar (p=NS) to that at the highest resolution (1.6 × 1.6 × 10.0 mm(3)). SNR in intensity-time plots through the soft palate was highest with 2.7 × 2.7 × 10.0 mm(3) resolution (20 fps). At 3 T, SSFP images are of a reliable quality, but 1.5 T bSSFP images are often better. For geometric measurements, temporal should be traded for spatial resolution (1.9 × 1.9 × 10.0 mm(3), 10 fps). For assessment of motion, temporal should be prioritised over spatial resolution (2.7 × 2.7 × 10.0 mm(3), 20 fps). Advances in knowledge Diagnostic quality real-time soft palate MRI is possible using clinical scanners and optimised protocols have been developed. 3 T SSFP imaging is reliable, but 1.5 T bSSFP often produces better images.
Pyroprocessing of Light Water Reactor Spent Fuels Based on an Electrochemical Reduction Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohta, Hirokazu; Inoue, Tadashi; Sakamura, Yoshiharu
A concept of pyroprocessing light water reactor (LWR) spent fuels based on an electrochemical reduction technology is proposed, and the material balance of the processing of mixed oxide (MOX) or high-burnup uranium oxide (UO{sub 2}) spent fuel is evaluated. Furthermore, a burnup analysis for metal fuel fast breeder reactors (FBRs) is conducted on low-decontamination materials recovered by pyroprocessing. In the case of processing MOX spent fuel (40 GWd/t), UO{sub 2} is separately collected for {approx}60 wt% of the spent fuel in advance of the electrochemical reduction step, and the product recovered through the rare earth (RE) removal step, which hasmore » the composition uranium:plutonium:minor actinides:fission products (FPs) = 76.4:18.4:1.7:3.5, can be applied as an ingredient of FBR metal fuel without a further decontamination process. On the other hand, the electroreduced alloy of high-burnup UO{sub 2} spent fuel (48 GWd/t) requires further decontamination of residual FPs by an additional process such as electrorefining even if RE FPs are removed from the alloy because the recovered plutonium (Pu) is accompanied by almost the same amount of FPs in addition to RE. However, the amount of treated materials in the electrorefining step is reduced to {approx}10 wt% of the total spent fuel owing to the prior UO{sub 2} recovery step. These results reveal that the application of electrochemical reduction technology to LWR spent oxide fuel is a promising concept for providing FBR metal fuel by a rationalized process.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, Don; Rearden, Bradley T; Reed, Davis Allan
2010-01-01
One of the challenges associated with implementation of burnup credit is the validation of criticality calculations used in the safety evaluation; in particular the availability and use of applicable critical experiment data. The purpose of the validation is to quantify the relationship between reality and calculated results. Validation and determination of bias and bias uncertainty require the identification of sets of critical experiments that are similar to the criticality safety models. A principal challenge for crediting fission products (FP) in a burnup credit safety evaluation is the limited availability of relevant FP critical experiments for bias and bias uncertainty determination.more » This paper provides an evaluation of the available critical experiments that include FPs, along with bounding, burnup-dependent estimates of FP biases generated by combining energy dependent sensitivity data for a typical burnup credit application with the nuclear data uncertainty information distributed with SCALE 6. A method for determining separate bias and bias uncertainty values for individual FPs and illustrative results is presented. Finally, a FP bias calculation method based on data adjustment techniques and reactivity sensitivity coefficients calculated with the SCALE sensitivity/uncertainty tools and some typical results is presented. Using the methods described in this paper, the cross-section bias for a representative high-capacity spent fuel cask associated with the ENDF/B-VII nuclear data for 16 most important stable or near stable FPs is predicted to be no greater than 2% of the total worth of the 16 FPs, or less than 0.13 % k/k.« less
A novel computer-aided detection system for pulmonary nodule identification in CT images
NASA Astrophysics Data System (ADS)
Han, Hao; Li, Lihong; Wang, Huafeng; Zhang, Hao; Moore, William; Liang, Zhengrong
2014-03-01
Computer-aided detection (CADe) of pulmonary nodules from computer tomography (CT) scans is critical for assisting radiologists to identify lung lesions at an early stage. In this paper, we propose a novel approach for CADe of lung nodules using a two-stage vector quantization (VQ) scheme. The first-stage VQ aims to extract lung from the chest volume, while the second-stage VQ is designed to extract initial nodule candidates (INCs) within the lung volume. Then rule-based expert filtering is employed to prune obvious FPs from INCs, and the commonly-used support vector machine (SVM) classifier is adopted to further reduce the FPs. The proposed system was validated on 100 CT scans randomly selected from the 262 scans that have at least one juxta-pleural nodule annotation in the publicly available database - Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI). The two-stage VQ only missed 2 out of the 207 nodules at agreement level 1, and the INCs detection for each scan took about 30 seconds in average. Expert filtering reduced FPs more than 18 times, while maintaining a sensitivity of 93.24%. As it is trivial to distinguish INCs attached to pleural wall versus not on wall, we investigated the feasibility of training different SVM classifiers to further reduce FPs from these two kinds of INCs. Experiment results indicated that SVM classification over the entire set of INCs was in favor of, where the optimal operating of our CADe system achieved a sensitivity of 89.4% at a specificity of 86.8%.
Ng, Jason S; Shih, Brian
2017-05-11
Minimizing false-positives (FPs) when evaluating color vision is important in eye care. Identification of plate 1 (demonstration plate) is often considered a way to avoid FPs. However, few studies have quantified the minimum level of visual acuity (VA) that would minimize FPs for the Ishihara and HRR color tests. Threshold levels of optical defocus were obtained from 25 color normal subjects. Blur levels were obtained for Ishihara (38 plate) plates 1, 10, and 15 and 4th edition HRR plates 1, 7, 10, and 20 using the method of limits. Corresponding VAs were measured through these blur levels at 40 centimeters after adjusting for the dioptric distance difference. Analysis of variance testing was used to analyze the data. Mean optical defocus values in diopters (mean ± SD) for HRR plates 1, 7, 10, and 20 were 6.23 ± 1.61, 1.23 ± 1.16, 2.41 ± 1.31, and 7.96 ± 2.03, respectively, and for Ishihara plates 1, 10, and 15 were 5.70 ± 1.52, 3.68 ± 1.71, and 4.62 ± 1.56, respectively. There was a significant difference between the screening and demonstration plates for both tests (p<0.001). Based on the plate in each test that was found to be the least tolerant to blur, the average minimum VAs needed to identify the screening plates were approximately 20/180 for the Ishihara test and 20/50 for the HRR test. Identifying the demonstration plate in the Ishihara and HRR tests does not ensure FPs will be avoided.
Schaufele, Fred
2013-01-01
Förster resonance energy transfer (FRET) between fluorescent proteins (FPs) provides insights into the proximities and orientations of FPs as surrogates of the biochemical interactions and structures of the factors to which the FPs are genetically fused. As powerful as FRET methods are, technical issues have impeded their broad adoption in the biologic sciences. One hurdle to accurate and reproducible FRET microscopy measurement stems from variable fluorescence backgrounds both within a field and between different fields. Those variations introduce errors into the precise quantification of fluorescence levels on which the quantitative accuracy of FRET measurement is highly dependent. This measurement error is particularly problematic for screening campaigns since minimal well-to-well variation is necessary to faithfully identify wells with altered values. High content screening depends also upon maximizing the numbers of cells imaged, which is best achieved by low magnification high throughput microscopy. But, low magnification introduces flat-field correction issues that degrade the accuracy of background correction to cause poor reproducibility in FRET measurement. For live cell imaging, fluorescence of cell culture media in the fluorescence collection channels for the FPs commonly used for FRET analysis is a high source of background error. These signal-to-noise problems are compounded by the desire to express proteins at biologically meaningful levels that may only be marginally above the strong fluorescence background. Here, techniques are presented that correct for background fluctuations. Accurate calculation of FRET is realized even from images in which a non-flat background is 10-fold higher than the signal. PMID:23927839
Frequency of in-office emergencies in primary care
Liddy, Clare; Dreise, Heather; Gaboury, Isabelle
2009-01-01
ABSTRACT OBJECTIVE To quantify the frequency and types of in-office emergencies seen by FPs. DESIGN A retrospective descriptive analysis of the frequency and types of in-office emergencies seen by FPs was done using the City of Ottawa Emergency Medical Services database. SETTING Community medical offices in the Ottawa, Ont, region during a 3-year period (2004 to 2006). PARTICIPANTS All patients for whom an ambulance was called to a medical office or clinic during the study period. MAIN OUTCOME MEASURES Number of emergency calls from FPs’ offices, primary complaints, seasonal variation, distance to the nearest emergency facility, and patients’ demographic characteristics. RESULTS A total of 3033 code 04 (life-threatening) emergency calls were received from FPs’ offices during the study period. Demographic analysis of the calls showed that 91.3% of calls were regarding adult patients with an average age of 51.5 years. There was an overall statistically significant difference in the sex of the patients presenting (P < .001), but it was attributable to calls about genitourinary emergencies, which were almost all for women. The most common type of emergency reported was cardiovascular complaints. Of the 992 cardiovascular emergencies, 74.3% were complaints of ischemic chest pain. CONCLUSION There is a great burden on the health care system from emergency calls, with continued unpreparedness from FPs. Clearly, FPs must take seriously the risk of being unprepared for in-office emergencies. Dissemination strategies must be developed so that the guidelines that have been developed can be effectively implemented in FP offices across the country. PMID:19826161
Too Many Referrals of Low-risk Women for BRCA1/2 Genetic Services by Family Physicians
White, Della Brown; Bonham, Vence L.; Jenkins, Jean; Stevens, Nancy; McBride, Colleen M.
2009-01-01
Increasing availability and public awareness of BRCA1/2 genetic testing will increase women’s self-referrals to genetic services. The objective of this study was to examine whether patient characteristics influence family physicians’ (FPs’) referral decisions when a patient requests BRCA1/2 genetic testing. FPs (n = 284) completed a web-based survey in 2006 to assess their attitudes and practices related to using genetics in their clinical practice. Using a 2×2×2 factorial design we tested the effects of a hypothetical patient’s race, level of worry and insurance status on FPs’ decisions to refer her for BRCA1/2 testing. The patient was not appropriate for referral based on USPSTF guidelines. No patient characteristics were associated with FPs’ referral decisions. Although referral was not indicated, only 8% did not refer to genetic services, 92% referred for genetic services, and 50% referred to genetic counseling. FPs regarded it unlikely that the patient carried a mutation. However, 65% of FPs believed if they refused to refer for genetic services it would harm their relationship with the patient. Despite scarce and costly genetic services FPs were likely to inappropriately refer a low-risk patient who requested BRCA1/2 testing. The implications of this inappropriate referral on women’s screening behavior, genetic services, and health care costs are unknown. Clinicians and patients could benefit from education about appropriate use of genetic services so that both are more comfortable with a decision against referral. PMID:18990739
Flight Characteristics of a 1/4-Scale Model of the XFV-1 Airplane (TED No. NACA DE-378)
NASA Technical Reports Server (NTRS)
Kelly, Mark W.; Smaus, Louis H.
1952-01-01
A l/4-scale dynamically similar model of the XFV-1 airplane has been flown in the Ames 40- by 80-foot wind tunnel, using the trailing flight-cable technique. This investigation was devoted to establishing the flight characteristics of the model in forward flight from hovering to wing stall, and in yawed flight (wing span alined with the relative wind) from hovering to the maximum speed at which controlled flight could be maintained. Landings, take-offs, and hovering characteristics in flights close to the ground were also investigated.. Since the remote control system for the model was rather complicated and provided artificial damping about the pitch, roll, and yaw axes, sufficient data from the control-system calibration tests are included in this report to specify the performance of the control system in relation to both the model flight tests and the design of an automatic control system for the full-scale airplane. The model in hovering flight appeared to be neutrally stable. The response of the model to the controls was very rapid, and it was always necessary to provide some amount of artificial damping to maintain control. The model could be landed with little difficulty by hovering approximately a foot above the floor and then cutting the power. Take-offs were more difficult to perform, primarily because the rate of change in power to the model motors was limited by the characteristics of the available power source. The model was,capable of controlled yawed flight at translational velocities up to and including 20 feet per second. The effectiveness of the controls decreased with increasing speed, however, and at 25 fps control in pitch, and probably roll, was lost completely. The model was flown in controlled forward flight from hovering up to 70 fps. During these flights the model appeared to be more difficult to control in yaw than it was in pitch or roll. The flights of the model were recorded by motion picture cameras. These motion pictures are available on loan from NACA Headquarters as a film supplement to this report.
Evaluation of Analytical Modeling Functions for the Phonation Onset Process.
Petermann, Simon; Kniesburges, Stefan; Ziethe, Anke; Schützenberger, Anne; Döllinger, Michael
2016-01-01
The human voice originates from oscillations of the vocal folds in the larynx. The duration of the voice onset (VO), called the voice onset time (VOT), is currently under investigation as a clinical indicator for correct laryngeal functionality. Different analytical approaches for computing the VOT based on endoscopic imaging were compared to determine the most reliable method to quantify automatically the transient vocal fold oscillations during VO. Transnasal endoscopic imaging in combination with a high-speed camera (8000 fps) was applied to visualize the phonation onset process. Two different definitions of VO interval were investigated. Six analytical functions were tested that approximate the envelope of the filtered or unfiltered glottal area waveform (GAW) during phonation onset. A total of 126 recordings from nine healthy males and 210 recordings from 15 healthy females were evaluated. Three criteria were analyzed to determine the most appropriate computation approach: (1) reliability of the fit function for a correct approximation of VO; (2) consistency represented by the standard deviation of VOT; and (3) accuracy of the approximation of VO. The results suggest the computation of VOT by a fourth-order polynomial approximation in the interval between 32.2 and 67.8% of the saturation amplitude of the filtered GAW.
High-speed particle tracking in microscopy using SPAD image sensors
NASA Astrophysics Data System (ADS)
Gyongy, Istvan; Davies, Amy; Miguelez Crespo, Allende; Green, Andrew; Dutton, Neale A. W.; Duncan, Rory R.; Rickman, Colin; Henderson, Robert K.; Dalgarno, Paul A.
2018-02-01
Single photon avalanche diodes (SPADs) are used in a wide range of applications, from fluorescence lifetime imaging microscopy (FLIM) to time-of-flight (ToF) 3D imaging. SPAD arrays are becoming increasingly established, combining the unique properties of SPADs with widefield camera configurations. Traditionally, the photosensitive area (fill factor) of SPAD arrays has been limited by the in-pixel digital electronics. However, recent designs have demonstrated that by replacing the complex digital pixel logic with simple binary pixels and external frame summation, the fill factor can be increased considerably. A significant advantage of such binary SPAD arrays is the high frame rates offered by the sensors (>100kFPS), which opens up new possibilities for capturing ultra-fast temporal dynamics in, for example, life science cellular imaging. In this work we consider the use of novel binary SPAD arrays in high-speed particle tracking in microscopy. We demonstrate the tracking of fluorescent microspheres undergoing Brownian motion, and in intra-cellular vesicle dynamics, at high frame rates. We thereby show how binary SPAD arrays can offer an important advance in live cell imaging in such fields as intercellular communication, cell trafficking and cell signaling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitrakusuma, Windy H., E-mail: windyhm@polban.ac.id; Refrigeration and Airconditioning Department, Politeknik Negeri Bandung, Jl. Gegerkalong Hilir, Ds. Ciwaruga Kotak Pos 1234 Bandung; Deendarlianto,
2016-06-03
Onset of nucleate boiling of a droplet when impacted onto hot surface was investigated. Three kinds of surfaces, normal stainless steel (NSS), stainless steel with TiO{sub 2} coating (UVN), and stainless steel with TiO{sub 2} coating and radiated by ultraviolet ray were employed to examine the effect of wettability. The droplet size was 2.4 mm diameter, and dropped under different We number. The image is generated by high speed camera with the frame speed of 1000 fps. The boiling conditions are identified as natural convection, nucleate boiling, critical heat flux, transition, and film boiling. In the present report, the discussionmore » will be focused on the beginning of nucleate boiling on the droplet. Nucleate boiling occurs when bubbles are generated. These bubbles are probably caused by nucleation on the impurities within the liquid rather than at nucleation sites on the heated surface because the bubbles appear to be in the bulk of the liquid instead of at the liquid-solid interface. In addition, the smaller the contact angle, the fastest the boiling.« less
Real-time range acquisition by adaptive structured light.
Koninckx, Thomas P; Van Gool, Luc
2006-03-01
The goal of this paper is to provide a "self-adaptive" system for real-time range acquisition. Reconstructions are based on a single frame structured light illumination. Instead of using generic, static coding that is supposed to work under all circumstances, system adaptation is proposed. This occurs on-the-fly and renders the system more robust against instant scene variability and creates suitable patterns at startup. A continuous trade-off between speed and quality is made. A weighted combination of different coding cues--based upon pattern color, geometry, and tracking--yields a robust way to solve the correspondence problem. The individual coding cues are automatically adapted within a considered family of patterns. The weights to combine them are based on the average consistency with the result within a small time-window. The integration itself is done by reformulating the problem as a graph cut. Also, the camera-projector configuration is taken into account for generating the projection patterns. The correctness of the range maps is not guaranteed, but an estimation of the uncertainty is provided for each part of the reconstruction. Our prototype is implemented using unmodified consumer hardware only and, therefore, is cheap. Frame rates vary between 10 and 25 fps, dependent on scene complexity.
Shear alters motility of Escherichia coli
NASA Astrophysics Data System (ADS)
Molaei, Mehdi; Jalali, Maryam; Sheng, Jian
2013-11-01
Understanding of locomotion of microorganisms in shear flows drew a wide range of interests in microbial related topics such as biological process including pathogenic infection and biophysical interactions like biofilm formation on engineering surfaces. We employed microfluidics and digital holography microscopy to study motility of E. coli in shear flows. We controlled the shear flow in three different shear rates: 0.28 s-1, 2.8 s-1, and 28 s-1 in a straight channel with the depth of 200 μm. Magnified holograms, recorded at 15 fps with a CCD camera over more than 20 minutes, are analyzed to obtain 3D swimming trajectories and subsequently used to extract shear responses of E.coli. Thousands of 3-D bacterial trajectories are tracked. The change of bacteria swimming characteristics including swimming velocity, reorientation, and dispersion coefficient are computed directly for individual trajectory and ensemble averaged over thousands of realizations. The results show that shear suppresses the bacterial dispersions in bulk but promote dispersions near the surface contrary to those in quiescent flow condition. Ongoing analyses are focusing to quantify effect of shear rates on tumbling frequency and reorientation of cell body, and its implication in locating the hydrodynamic mechanisms for shear enhanced angular scattering. NIH, NSF, GoMRI.
CMOS Image Sensors for High Speed Applications.
El-Desouki, Munir; Deen, M Jamal; Fang, Qiyin; Liu, Louis; Tse, Frances; Armstrong, David
2009-01-01
Recent advances in deep submicron CMOS technologies and improved pixel designs have enabled CMOS-based imagers to surpass charge-coupled devices (CCD) imaging technology for mainstream applications. The parallel outputs that CMOS imagers can offer, in addition to complete camera-on-a-chip solutions due to being fabricated in standard CMOS technologies, result in compelling advantages in speed and system throughput. Since there is a practical limit on the minimum pixel size (4∼5 μm) due to limitations in the optics, CMOS technology scaling can allow for an increased number of transistors to be integrated into the pixel to improve both detection and signal processing. Such smart pixels truly show the potential of CMOS technology for imaging applications allowing CMOS imagers to achieve the image quality and global shuttering performance necessary to meet the demands of ultrahigh-speed applications. In this paper, a review of CMOS-based high-speed imager design is presented and the various implementations that target ultrahigh-speed imaging are described. This work also discusses the design, layout and simulation results of an ultrahigh acquisition rate CMOS active-pixel sensor imager that can take 8 frames at a rate of more than a billion frames per second (fps).
NASA Astrophysics Data System (ADS)
Montoya, Gustavo; Valecillos, María; Romero, Carlos; Gonzáles, Dosinda
2009-11-01
In the present research a digital image processing-based automated algorithm was developed in order to determine the phase's height, hold up, and statistical distribution of the drop size in a two-phase system water-air using pipes with 0 , 10 , and 90 of inclination. Digital images were acquired with a high speed camera (up to 4500fps), using an equipment that consist of a system with three acrylic pipes with diameters of 1.905, 3.175, and 4.445 cm. Each pipe is arranged in two sections of 8 m of length. Various flow patterns were visualized for different superficial velocities of water and air. Finally, using the image processing program designed in Matlab/Simulink^, the captured images were processed to establish the parameters previously mentioned. The image processing algorithm is based in the frequency domain analysis of the source pictures, which allows to find the phase as the edge between the water and air, through a Sobel filter that extracts the high frequency components of the image. The drop size was found using the calculation of the Feret diameter. Three flow patterns were observed: Annular, ST, and ST&MI.
NASA Astrophysics Data System (ADS)
Venugopal, Vivek; Park, Minho; Ashitate, Yoshitomo; Neacsu, Florin; Kettenring, Frank; Frangioni, John V.; Gangadharan, Sidhu P.; Gioux, Sylvain
2013-12-01
We report the design, characterization, and validation of an optimized simultaneous color and near-infrared (NIR) fluorescence rigid endoscopic imaging system for minimally invasive surgery. This system is optimized for illumination and collection of NIR wavelengths allowing the simultaneous acquisition of both color and NIR fluorescence at frame rates higher than 6.8 fps with high sensitivity. The system employs a custom 10-mm diameter rigid endoscope optimized for NIR transmission. A dual-channel light source compatible with the constraints of an endoscope was built and includes a plasma source for white light illumination and NIR laser diodes for fluorescence excitation. A prism-based 2-CCD camera was customized for simultaneous color and NIR detection with a highly efficient filtration scheme for fluorescence imaging of both 700- and 800-nm emission dyes. The performance characterization studies indicate that the endoscope can efficiently detect fluorescence signal from both indocyanine green and methylene blue in dimethyl sulfoxide at the concentrations of 100 to 185 nM depending on the background optical properties. Finally, we performed the validation of this imaging system in vivo during a minimally invasive procedure for thoracic sentinel lymph node mapping in a porcine model.
Evaporation-induced gas-phase flows at selective laser melting
NASA Astrophysics Data System (ADS)
Zhirnov, I.; Kotoban, D. V.; Gusarov, A. V.
2018-02-01
Selective laser melting is the method for 3D printing from metals. A solid part is built from powder layer-by-layer. A continuum-wave laser beam scans every powder layer to fuse powder. The process is studied with a high-speed CCD camera at the frame rate of 104 fps and the resolution up to 5 µm per pixel. Heat transfer and evaporation in the laser-interaction zone are numerically modeled. Droplets are ejected from the melt pool in the direction around the normal to the melt surface and the powder particles move in the horizontal plane toward the melt pool. A vapor jet is observed in the direction of the normal to the melt surface. The velocities of the droplets, the powder particles, and the jet flow and the mass loss due to evaporation are measured. The gas flow around the vapor jet is calculated by Landau's model of submerged jet. The measured velocities of vapor, droplets, and powder particles correlate with the calculated flow field. The obtained results show the importance of evaporation and the flow of the vapor and the ambient gas. These gas-dynamic phenomena can explain the formation of the denudated zones and the instability at high-energy input.
Multiple pulsed hypersonic liquid diesel fuel jetsdriven by projectile impact
NASA Astrophysics Data System (ADS)
Pianthong, K.; Takayama, K.; Milton, B. E.; Behnia, M.
2005-06-01
Further studies on high-speed liquid diesel fuel jets injected into ambient air conditions have been carried out. Projectile impact has been used as the driving mechanism. A vertical two-stage light gas gun was used as a launcher to provide the high-speed impact. This paper describes the experimental technique and visualization methods that provided a rapid series of jet images in the one shot. A high-speed video camera (106 fps) and shadowgraph optical system were used to obtain visualization. Very interesting and unique phenomena have been discovered and confirmed in this study. These are that multiple high frequency jet pulses are generated within the duration of a single shot impact. The associated multiple jet shock waves have been clearly captured. This characteristic consistently occurs with the smaller conical angle, straight cone nozzles but not with those with a very wide cone angle or curved nozzle profile. An instantaneous jet tip velocity of 2680 m/s (Mach number of 7.86) was the maximum obtained with the 40^circ nozzle. However, this jet tip velocity can only be sustained for a few microseconds as attenuation is very rapid.
Cinematographical analysis of javelin throwing techniques of decathletes.
Kunz, H.; Kaufmann, D. A.
1983-01-01
Th purpose of this study was to analyse by correlational methods the biomechanical factors involved in achieving the maximal distance thrown in the javelin event. Twelve Swiss decathletes and two world class javelin specialists were filmed by a high speed (102 fps) 16 mm camera throwing a total of 20 trials. The co-ordinates of the resulting cyclograms were processed by a computer programme and the results submitted to correlational analysis. The highest correlation was 0.76 between velocity at release and distance thrown. Other negative correlations were found between distance thrown and angle of the javelin with the horizontal (0.52) and distance thrown and throwing hand to contralateral foot distance during the last strides (0.67). Javelin specialists, who had longer throws than decathletes (mean = 79.03 m versus 54.29 m), had a smaller difference between the angle of attack and angle of release. The results suggest that in order to attain maximal distance thrown the javelin thrower should achieve positive acceleration during the running approach, effective thrusting with th right leg on the penultimate stride and carry the javelin during the last strides at the optimal angle of release (32 to 36 degrees). Images p200-a p200-b PMID:6652405
Algorithm for Automatic Behavior Quantification of Laboratory Mice Using High-Frame-Rate Videos
NASA Astrophysics Data System (ADS)
Nie, Yuman; Takaki, Takeshi; Ishii, Idaku; Matsuda, Hiroshi
In this paper, we propose an algorithm for automatic behavior quantification in laboratory mice to quantify several model behaviors. The algorithm can detect repetitive motions of the fore- or hind-limbs at several or dozens of hertz, which are too rapid for the naked eye, from high-frame-rate video images. Multiple repetitive motions can always be identified from periodic frame-differential image features in four segmented regions — the head, left side, right side, and tail. Even when a mouse changes its posture and orientation relative to the camera, these features can still be extracted from the shift- and orientation-invariant shape of the mouse silhouette by using the polar coordinate system and adjusting the angle coordinate according to the head and tail positions. The effectiveness of the algorithm is evaluated by analyzing long-term 240-fps videos of four laboratory mice for six typical model behaviors: moving, rearing, immobility, head grooming, left-side scratching, and right-side scratching. The time durations for the model behaviors determined by the algorithm have detection/correction ratios greater than 80% for all the model behaviors. This shows good quantification results for actual animal testing.
A fast button surface defects detection method based on convolutional neural network
NASA Astrophysics Data System (ADS)
Liu, Lizhe; Cao, Danhua; Wu, Songlin; Wu, Yubin; Wei, Taoran
2018-01-01
Considering the complexity of the button surface texture and the variety of buttons and defects, we propose a fast visual method for button surface defect detection, based on convolutional neural network (CNN). CNN has the ability to extract the essential features by training, avoiding designing complex feature operators adapted to different kinds of buttons, textures and defects. Firstly, we obtain the normalized button region and then use HOG-SVM method to identify the front and back side of the button. Finally, a convolutional neural network is developed to recognize the defects. Aiming at detecting the subtle defects, we propose a network structure with multiple feature channels input. To deal with the defects of different scales, we take a strategy of multi-scale image block detection. The experimental results show that our method is valid for a variety of buttons and able to recognize all kinds of defects that have occurred, including dent, crack, stain, hole, wrong paint and uneven. The detection rate exceeds 96%, which is much better than traditional methods based on SVM and methods based on template match. Our method can reach the speed of 5 fps on DSP based smart camera with 600 MHz frequency.
NASA Astrophysics Data System (ADS)
Uchiyama, Yoshikazu; Gao, Xin; Hara, Takeshi; Fujita, Hiroshi; Ando, Hiromichi; Yamakawa, Hiroyasu; Asano, Takahiko; Kato, Hiroki; Iwama, Toru; Kanematsu, Masayuki; Hoshi, Hiroaki
2008-03-01
The detection of unruptured aneurysms is a major subject in magnetic resonance angiography (MRA). However, their accurate detection is often difficult because of the overlapping between the aneurysm and the adjacent vessels on maximum intensity projection images. The purpose of this study is to develop a computerized method for the detection of unruptured aneurysms in order to assist radiologists in image interpretation. The vessel regions were first segmented using gray-level thresholding and a region growing technique. The gradient concentration (GC) filter was then employed for the enhancement of the aneurysms. The initial candidates were identified in the GC image using a gray-level threshold. For the elimination of false positives (FPs), we determined shape features and an anatomical location feature. Finally, rule-based schemes and quadratic discriminant analysis were employed along with these features for distinguishing between the aneurysms and the FPs. The sensitivity for the detection of unruptured aneurysms was 90.0% with 1.52 FPs per patient. Our computerized scheme can be useful in assisting the radiologists in the detection of unruptured aneurysms in MRA images.
HVS-based quantization steps for validation of digital cinema extended bitrates
NASA Astrophysics Data System (ADS)
Larabi, M.-C.; Pellegrin, P.; Anciaux, G.; Devaux, F.-O.; Tulet, O.; Macq, B.; Fernandez, C.
2009-02-01
In Digital Cinema, the video compression must be as transparent as possible to provide the best image quality to the audience. The goal of compression is to simplify transport, storing, distribution and projection of films. For all those tasks, equipments need to be developed. It is thus mandatory to reduce the complexity of the equipments by imposing limitations in the specifications. In this sense, the DCI has fixed the maximum bitrate for a compressed stream to 250 Mbps independently from the input format (4K/24fps, 2K/48fps or 2K/24fps). The work described in this paper This parameter is discussed in this paper because it is not consistent to double/quadruple the input rate without increasing the output rate. The work presented in this paper is intended to define quantization steps ensuring the visually lossless compression. Two steps are followed first to evaluate the effect of each subband separately and then to fin the scaling ratio. The obtained results show that it is necessary to increase the bitrate limit for cinema material in order to achieve the visually lossless.
Development of Neuromorphic Sift Operator with Application to High Speed Image Matching
NASA Astrophysics Data System (ADS)
Shankayi, M.; Saadatseresht, M.; Bitetto, M. A. V.
2015-12-01
There was always a speed/accuracy challenge in photogrammetric mapping process, including feature detection and matching. Most of the researches have improved algorithm's speed with simplifications or software modifications which increase the accuracy of the image matching process. This research tries to improve speed without enhancing the accuracy of the same algorithm using Neuromorphic techniques. In this research we have developed a general design of a Neuromorphic ASIC to handle algorithms such as SIFT. We also have investigated neural assignment in each step of the SIFT algorithm. With a rough estimation based on delay of the used elements including MAC and comparator, we have estimated the resulting chip's performance for 3 scenarios, Full HD movie (Videogrammetry), 24 MP (UAV photogrammetry), and 88 MP image sequence. Our estimations led to approximate 3000 fps for Full HD movie, 250 fps for 24 MP image sequence and 68 fps for 88MP Ultracam image sequence which can be a huge improvement for current photogrammetric processing systems. We also estimated the power consumption of less than10 watts which is not comparable to current workflows.
A breakdown enhanced AlGaN/GaN MISFET with source-connected P-buried layer
NASA Astrophysics Data System (ADS)
Luo, Xin; Wang, Ying; Cao, Fei; Yu, Cheng-Hao; Fei, Xin-Xing
2017-12-01
This paper presents a breakdown-enhanced AlGaN/GaN MISFET with a source-connected P-buried layer combined with field plates (SC-PBL FPs MISFET). A TCAD tool was used to analyze the breakdown characteristics of the proposed structure, and results show that in comparison to the conventional gate field plate MISFET (GFP-C MISFET), the proposed structure provides a significant increase of breakdown voltage (VBK) due to redistribution of electric field in the gate-drain region induced by the SC-PBL and the FPs. The optimized SC-PBL FPs MISFET with a gate-drain spacing of 6 μm achieved a high Baliga's figure of merit of 2.6 GW cm-2 with a corresponding breakdown voltage (VBK) of 1311.62 V and specific on resistance (RON,sp) of 0.66 mΩ cm2, which demonstrates a good trade-off between RON,sp and VBK compared to the GFP-C MISFET with VBK of 524.27 V and RON,sp of 0.61 mΩ cm2.
ERIC Educational Resources Information Center
Pescosolido, Bernice A.
2008-01-01
Across the field of higher education and within the discipline of sociology, several important reconceptualizations of academic work have emerged. While not absolutely in sync, there is a striking overlap across three of the most visible of these: Boyer's Scholarship Reconsidered, Carnegie's Stewardship of the Discipline, and Burawoy's Public…
ERIC Educational Resources Information Center
Carr-Chellman, Alison
2012-01-01
Boy culture is out of sync with school culture. There are several reasons for this, including zero tolerance policies that are too often taken to extremes, the lack of male teachers, and the compression of the curriculum. What's more, boy culture is not socially accepted, and boys quickly come to feel that they are not good at school. For many…
Best Practice in Management Education: Capitalising on Gender Diversity Awareness.
ERIC Educational Resources Information Center
Smith, Catherine R.
1998-01-01
Responses from 50 women and 35 men (of 472) studying management in Australia identified sex bias in management education and suggested that orientation to gender issues of male educators and female students was significantly more out of sync than that of male educators and male students. A video on gender awareness was developed based on the…
NASA Astrophysics Data System (ADS)
Iglesias, F. A.; Feller, A.; Nagaraju, K.; Solanki, S. K.
2016-05-01
Context. Remote sensing of weak and small-scale solar magnetic fields is of utmost relevance when attempting to respond to a number of important open questions in solar physics. This requires the acquisition of spectropolarimetric data with high spatial resolution (~10-1 arcsec) and low noise (10-3 to 10-5 of the continuum intensity). The main limitations to obtain these measurements from the ground, are the degradation of the image resolution produced by atmospheric seeing and the seeing-induced crosstalk (SIC). Aims: We introduce the prototype of the Fast Solar Polarimeter (FSP), a new ground-based, high-cadence polarimeter that tackles the above-mentioned limitations by producing data that are optimally suited for the application of post-facto image restoration, and by operating at a modulation frequency of 100 Hz to reduce SIC. Methods: We describe the instrument in depth, including the fast pnCCD camera employed, the achromatic modulator package, the main calibration steps, the effects of the modulation frequency on the levels of seeing-induced spurious signals, and the effect of the camera properties on the image restoration quality. Results: The pnCCD camera reaches 400 fps while keeping a high duty cycle (98.6%) and very low noise (4.94 e- rms). The modulator is optimized to have high (>80%) total polarimetric efficiency in the visible spectral range. This allows FSP to acquire 100 photon-noise-limited, full-Stokes measurements per second. We found that the seeing induced signals that are present in narrow-band, non-modulated, quiet-sun measurements are (a) lower than the noise (7 × 10-5) after integrating 7.66 min, (b) lower than the noise (2.3 × 10-4) after integrating 1.16 min and (c) slightly above the noise (4 × 10-3) after restoring case (b) by means of a multi-object multi-frame blind deconvolution. In addition, we demonstrate that by using only narrow-band images (with low S/N of 13.9) of an active region, we can obtain one complete set of high-quality restored measurements about every 2 s.
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.
2011-01-01
The Fission Power System (FPS) project is developing a Technology Demonstration Unit (TDU) to verify the performance and functionality of a subscale version of the FPS reference concept in a relevant environment, and to verify component and system models. As hardware is developed for the TDU, component and system models must be refined to include the details of specific component designs. This paper describes the development of a Sage-based pseudo-steady-state Stirling convertor model and its implementation into a system-level model of the TDU.
Strategic management and performance differences: nonprofit versus for-profit health organizations.
Reeves, Terrie C; Ford, Eric W
2004-01-01
Despite mixed and contradictory findings, for-profits (FPs) and nonprofits (NPs) are assumed to be similar health services organizations (HSOs). In this study, a fifteen-item scale assessing HSOs' strategic management capacity was developed and tested using fifty-seven FP and twenty NP organizations. Then, using item response theory, the items were hierarchically profiled to produce two strategic profile models, a general and an FP anchored model. We find that deviation from the general profile, but not capability attainment level, is related to two of three financial measures. We conclude that studying FPs and NPs together is appropriate.
Alternate bearing design fabrication and test program, exhibit B
NASA Technical Reports Server (NTRS)
1978-01-01
A 50 ft-lb-sec (FPS) reaction wheel was modified with an ironless armature brushless dc motor and a magnetic bearing suspension. The purpose was to demonstrate the performance of an alternate bearing concept, i.e., a magnetic bearing suspension, which could be used in Skylab type CMG's to meet the attitude control requirements of long term space stations. A magnetic suspension was built, installed and tested in the 50 FPS reaction wheel. A secondary effort included the build and test of a compatible reaction wheel motor. Performance characteristics of both are presented and discussed.
Creating surfactant nanoparticles for block copolymer composites through surface chemistry.
Kim, Bumjoon J; Bang, Joona; Hawker, Craig J; Chiu, Julia J; Pine, David J; Jang, Se Gyu; Yang, Seung-Man; Kramer, Edward J
2007-12-04
A simple strategy to tailor the surface of nanoparticles for their specific adsorption to and localization at block copolymer interfaces was explored. Gold nanoparticles coated by a mixture of low molecular weight thiol end-functional polystyrene (PS-SH) (Mn = 1.5 and 3.4 kg/mol) and poly(2-vinylpyridine) homopolymers (P2VP-SH) (Mn = 1.5 and 3.0 kg/mol) were incorporated into a lamellar poly(styrene-b-2-vinylpyridine) diblock copolymer (PS-b-P2VP) (Mn = 196 kg/mol). A library of nanoparticles with varying PS and P2VP surface compositions (FPS) and high polymer ligand areal chain densities was synthesized. The location of the nanoparticles in the PS-b-P2VP block copolymer was determined by transmission electron microscopy. Sharp transitions in particle location from the PS domain to the PS/P2VP interface, and subsequently to the P2VP domain, were observed at FPS = 0.9 and 0.1, respectively. This extremely wide window of FPS values where the polymer-coated gold nanoparticles adsorb to the interface suggests a redistribution of PS and P2VP polymers on the Au surface, inducing the formation of amphiphilic nanoparticles at the PS/P2VP interface. In a second and synthetically more challenging approach, gold nanoparticles were covered with a thiol terminated random copolymer of styrene and 2-vinylpyridine synthesized by RAFT polymerization. Two different random copolymers were considered, where the molecular weight was fixed at 3.5 kg/mol and the relative incorporation of styrene and 2-vinylpyridine repeat units varied (FPS = 0.52 and 0.40). The areal chain density of these random copolymers on Au is unfortunately not high enough to preclude any contact between the P2VP block of the block copolymer and the Au surface. Interestingly, gold nanoparticles coated by the random copolymer with FPS = 0.4 were dispersed in the P2VP domain, while those with FPS = 0.52 were located at the interface. A simple calculation for the adsorption energy to the interface of the nanoparticles with different surface arrangements of PS and P2VP ligands supports evidence for the rearrangement of thiol terminated homopolymers. An upper limit estimate of the adsorption energy of nanoparticles uniformly coated with a random arrangement of PS and P2VP ligands where a 10% surface area was occupied by P2VP -mers or chains was approximately 1 kBT, which indicates that such nanoparticles are unlikely to be segregated along the interface, in contrast to the experimental results for nanoparticles with mixed ligand-coated surfaces.
Lessard, Chantale; Contandriopoulos, André-Pierre; Beaulieu, Marie-Dominique
2010-06-01
Despite increasing interest in health economic evaluation, investigations have shown limited use by micro (clinical) level decision-makers. A considerable amount of health decisions take place daily at the point of the clinical encounter; especially in primary care. Since every decision has an opportunity cost, ignoring economic information in family physicians' (FPs) decision-making may have a broad impact on health care efficiency. Knowledge translation of economic evaluation is often based on taken-for-granted assumptions about actors' interests and interactions, neglecting much of the complexity of social reality. Health economics literature frequently assumes a rational and linear decision-making process. Clinical decision-making is in fact a complex social, dynamic, multifaceted process, involving relationships and contextual embeddedness. FPs are embedded in complex social networks that have a significant impact on skills, attitudes, knowledge, practices, and on the information being used. Because of their socially constructed nature, understanding preferences, professional culture, practices, and knowledge translation requires serious attention to social reality. There has been little exploration by health economists of whether the problem may be more fundamental and reside in a misunderstanding of the process of decision-making. There is a need to enhance our understanding of the role of economic evaluation in decision-making from a disciplinary perspective different than health economics. This paper argues for a different conceptualization of the role of economic evaluation in FPs' decision-making, and proposes Bourdieu's sociological theory as a research framework. Bourdieu's theory of practice illustrates how the context-sensitive nature of practice must be understood as a socially constituted practical knowledge. The proposed approach could substantially contribute to a more complex understanding of the role of economic evaluation in FPs' decision-making. Copyright 2010 Elsevier Ltd. All rights reserved.