Sample records for fractionated atrial electrograms

  1. Unipolar atrial electrogram morphology from an epicardial and endocardial perspective.

    PubMed

    van der Does, Lisette J M E; Knops, Paul; Teuwen, Christophe P; Serban, Corina; Starreveld, Roeliene; Lanters, Eva A H; Mouws, Elisabeth M J P; Kik, Charles; Bogers, Ad J J C; de Groot, Natasja M S

    2018-02-22

    Endo-epicardial asynchrony (EEA) and the interplay between the endocardial and epicardial layers could be important in the pathophysiology of atrial arrhythmias. The morphologic differences between epicardial and endocardial atrial electrograms have not yet been described, and electrogram morphology may hold information about the presence of EEA. The purpose of this study was to directly compare epicardial to endocardial unipolar electrogram morphology during sinus rhythm (SR) and to evaluate whether EEA contributes to electrogram fractionation by correlating fractionation to spatial activation patterns. In 26 patients undergoing cardiac surgery, unipolar electrograms were simultaneously recorded from the epicardium and endocardium at the inferior, middle, and superior right atrial (RA) free wall during SR. Potentials were analyzed for epi-endocardial differences in local activation time, voltage, RS ratio, and fractionation. The surrounding and opposite electrograms of fractionated deflections were evaluated for corresponding local activation times in order to determine whether fractionation originated from EEA. The superior RA was predisposed to delayed activation, EEA, and fractionation. Both epicardial and endocardial electrograms demonstrated an S-predominance. Fractionation was mostly similar between the 2 sides; however, incidentally deflections up to 4 mV on 1 side could be absent on the other side. Remote activation was responsible for most fractionated deflections (95%) in SR, of which 4% could be attributed to EEA. Local epi-endocardial differences in electrogram fractionation occur occasionally during SR but will likely increase during arrhythmias due to increasing EEA and (functional) conduction disorders. Electrogram fractionation can originate from EEA, and this study demonstrated that unipolar electrogram fractionation can potentially identify EEA. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. Dynamic approximate entropy electroanatomic maps detect rotors in a simulated atrial fibrillation model.

    PubMed

    Ugarte, Juan P; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John

    2014-01-01

    There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping.

  3. Dynamic Approximate Entropy Electroanatomic Maps Detect Rotors in a Simulated Atrial Fibrillation Model

    PubMed Central

    Ugarte, Juan P.; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John

    2014-01-01

    There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping. PMID:25489858

  4. Electrogram fractionation in murine HL-1 atrial monolayer model.

    PubMed

    Umapathy, Karthikeyan; Masse, Stephane; Kolodziejska, Karolina; Veenhuyzen, George D; Chauhan, Vijay S; Husain, Mansoor; Farid, Talha; Downar, Eugene; Sevaptsidis, Elias; Nanthakumar, Kumaraswamy

    2008-07-01

    Complex fractionated atrial electrograms have been suggested as important targets for catheter ablation of atrial fibrillation. The etiology and the mechanism of these signals have not been completely elucidated because of limitations of interpretation of these signals in relation to simultaneously acquired signals in the neighboring atrial tissue. This study sought to study the origin of electrogram fractionation under the conditions of rotor formation and wave fragmentation, using atrial monolayer preparations. We performed optical mapping of 45 atrial monolayer preparations using a complementary metal oxide semiconductor (CMOS) Brainvision Ultima camera system (SciMedia-Brainvision, Tokyo, Japan). We observed stable rotors in 32 of the 45 recordings. The derived bipolar electrograms did not show complex fractionation at the core of the rotor in any of the 32 recordings. We were also able to show that 2 bipolar electrodes placed adjacent to the core of a stable rotor in a zone where there is no wave break will record electrical activity for the majority of the rotor's cycle length. In 13 of the 45 recordings, wave break or wave collision events were present. Of these, 8 of 13 recordings showed complex fractionation. In 19 of the 27, simulation of meandering rotors also showed complex fractionation. Complex fractionated electrograms can be recorded at sites of migrating rotors and wave break. No fractionation occurs at the core of a stable rotor. Electrograms that span the rotor cycle length and alternate between 2 bipoles that straddle the core can identify site of a stable rotor.

  5. Comparison of Left Atrial Voltage between Sinus Rhythm and Atrial Fibrillation in Association with Electrogram Waveform.

    PubMed

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Matsuda, Yasuhiro; Ohashi, Takuya; Uematsu, Masaaki

    2017-05-01

    The efficacy of low-voltage-guided ablation in addition to pulmonary vein (PV) isolation for atrial fibrillation (AF) has been reported with voltage mapping being performed during sinus rhythm (SR) or AF. The study aimed to compare the left atrial voltage between SR and AF in association with the electrogram waveform. This prospective observational study included 30 consecutive patients with persistent AF. After completion of PV isolation, electrogram points were taken during both SR and AF at the identical locations evenly throughout the left atrium. Electrograms were divided into two types: normal (sharp electrogram with ≤3 peaks or duration <50 ms) and fractionated (>3 peaks and duration ≥50 ms). During SR, 14 (47%) patients had low-voltage (0.5 mV) substrate with an area of 6.8 ± 4.5 cm 2 . In a total of 1,063 point pairs, 135 (13%) demonstrated a fractionated electrogram during SR and 483 (45%) during AF. The locations with fractionated electrograms during AF more frequently showed fractionation during SR compared to those with normal electrograms during AF (23% vs 5%, P < 0.0001), and had lower amplitude during SR (1.47 ± 1.29 mV vs 2.03 ± 1.19 mV, P < 0.0001). Electrogram amplitude was higher during SR than that during AF (1.77 ± 1.27 mV vs 0.96 ± 0.77 mV, P < 0.0001) with a weak correlation (r = 0.56, P < 0.0001). Subgroup analyses revealed that the correlation was relatively strong (r = 0.73, P < 0.0001) among the electrogram amplitudes with normal waveform during SR and AF. Significant differences in electrogram voltage and fractionation degree may exist between SR and AF at the same locations in patients with persistent AF. © 2017 Wiley Periodicals, Inc.

  6. Multifractal analysis for grading complex fractionated electrograms in atrial fibrillation.

    PubMed

    Orozco-Duque, A; Novak, D; Kremen, V; Bustamante, J

    2015-11-01

    Complex fractionated atrial electrograms provide an important tool for identifying arrhythmogenic substrates that can be used to guide catheter ablation for atrial fibrillation (AF). However, fractionation is a phenomenon that remains unclear. This paper aims to evaluate the multifractal properties of electrograms in AF in order to propose a method based on multifractal analysis able to discriminate between different levels of fractionation. We introduce a new method, the h-fluctuation index (hFI), where h is the generalised Hurst exponent, to extract information from the shape of the multifractal spectrum. Two multifractal frameworks are evaluated: multifractal detrended fluctuation analysis and wavelet transform modulus maxima. hFI is exemplified through its application in synthetic signals, and it is evaluated in a database of electrograms labeled on the basis of four degrees of fractionation. We compare the performance of hFI with other indexes, and find that hFI outperforms them. The results of the study provide evidence that multifractal analysis is useful for studying fractionation phenomena in AF electrograms, and indicate that hFI can be proposed as a tool for grade fractionation associated with the detection of target sites for ablation in AF.

  7. A Three-Dimensional Human Atrial Model with Fiber Orientation. Electrograms and Arrhythmic Activation Patterns Relationship

    PubMed Central

    Tobón, Catalina; Ruiz-Villa, Carlos A.; Heidenreich, Elvio; Romero, Lucia; Hornero, Fernando; Saiz, Javier

    2013-01-01

    The most common sustained cardiac arrhythmias in humans are atrial tachyarrhythmias, mainly atrial fibrillation. Areas of complex fractionated atrial electrograms and high dominant frequency have been proposed as critical regions for maintaining atrial fibrillation; however, there is a paucity of data on the relationship between the characteristics of electrograms and the propagation pattern underlying them. In this study, a realistic 3D computer model of the human atria has been developed to investigate this relationship. The model includes a realistic geometry with fiber orientation, anisotropic conductivity and electrophysiological heterogeneity. We simulated different tachyarrhythmic episodes applying both transient and continuous ectopic activity. Electrograms and their dominant frequency and organization index values were calculated over the entire atrial surface. Our simulations show electrograms with simple potentials, with little or no cycle length variations, narrow frequency peaks and high organization index values during stable and regular activity as the observed in atrial flutter, atrial tachycardia (except in areas of conduction block) and in areas closer to ectopic activity during focal atrial fibrillation. By contrast, cycle length variations and polymorphic electrograms with single, double and fragmented potentials were observed in areas of irregular and unstable activity during atrial fibrillation episodes. Our results also show: 1) electrograms with potentials without negative deflection related to spiral or curved wavefronts that pass over the recording point and move away, 2) potentials with a much greater proportion of positive deflection than negative in areas of wave collisions, 3) double potentials related with wave fragmentations or blocking lines and 4) fragmented electrograms associated with pivot points. Our model is the first human atrial model with realistic fiber orientation used to investigate the relationship between different atrial arrhythmic propagation patterns and the electrograms observed at more than 43000 points on the atrial surface. PMID:23408928

  8. Rotor meandering contributes to irregularity in electrograms during atrial fibrillation.

    PubMed

    Zlochiver, Sharon; Yamazaki, Masatoshi; Kalifa, Jérôme; Berenfeld, Omer

    2008-06-01

    Radiofrequency ablation therapy of atrial fibrillation (AF) recently incorporated the analysis of dominant frequency (DF) and/or electrogram fractionation for guidance. However, the relationships between DF, fractionation, and spatiotemporal characteristics of the AF source remain unclear. We hypothesize that a meandering reentrant AF source contributes to the wave fractionation and is reflected in the power spectrum of local electrograms elsewhere in the rotor's surroundings. Meandering rotors as AF sources were simulated in 2-dimensional models of human atrial tissue and recorded in isolated sheep hearts. Nondominant elements of the signals were differentiated from the dominant elements using singular value decomposition, whereby the purely periodic constituent (PC) relating to the rotor's DF was eliminated rendering a residual constituent (RC) that consisted of all other activity. Spectral analysis of the decomposed constituents revealed peaks corresponding to the meandering frequency of the rotor tip, the magnitudes of which were proportional to the size of and the distance to the rotor core. Similar analyses on epicardial optical signals and electrograms from isolated sheep hearts, as well as human complex fractionated atrial electrograms, showed applicability of the approach. Increased meandering of the rotor driving AF reduces activation periodicity and increases fractionation. The spectral manifestation of the rotor activity beyond the meandering region makes it possible to characterize AF source stability, as well as DF in humans using electrode mapping.

  9. Rotor Meandering Contributes to Irregularity in Electrograms during Atrial Fibrillation

    PubMed Central

    Zlochiver, Sharon; Yamazaki, Masatoshi; Kalifa, Jerome; Berenfeld, Omer

    2010-01-01

    Radiofrequency ablation therapy of atrial fibrillation (AF) recently incorporated the analysis of dominant frequency (DF) and/or electrogram fractionation for guidance. However, the relationships between DF, fractionation and spatio-temporal characteristics of the AF source remain unclear. We hypothesize that meandering reentrant AF source contributes to the wave fractionation and is reflected in the power spectrum of local electrograms elsewhere in the rotor’s surroundings. Methods Meandering rotors as AF sources were simulated in 2D models of human atrial tissue and recorded in isolated sheep hearts. Non-dominant elements of the signals were differentiated from the dominant elements using singular value decomposition, whereby the purely periodic constituent (PC) relating to the rotor’s DF was eliminated rendering a residual constituent (RC) that consisted of all other activity. Results Spectral analysis of the decomposed constituents revealed peaks corresponding to the meandering frequency of the rotor tip, the magnitudes of which were proportional to the size of, and the distance to the rotor core. Similar analyses on epicardial optical signals and electrograms from isolated sheep hearts, as well as human complex fractionated atrial electrograms demonstrated applicability of the approach. Conclusion Increased meandering of the rotor driving AF reduces activation periodicity and increases fractionation. The spectral manifestation of the rotor activity beyond the meandering region makes it possible to characterize AF source stability, as well as DF in humans using electrode mapping. PMID:18534369

  10. Validation of a classification system to grade fractionation in atrial fibrillation and correlation with automated detection systems.

    PubMed

    Hunter, Ross J; Diab, Ihab; Thomas, Glyn; Duncan, Edward; Abrams, Dominic; Dhinoja, Mehul; Sporton, Simon; Earley, Mark J; Schilling, Richard J

    2009-12-01

    We tested application of a grading system describing complex fractionated electrograms (CFE) in atrial fibrillation (AF) and used it to validate automated CFE detection (AUTO). Ten seconds bipolar electrograms were classified by visual inspection (VI) during ablation of persistent AF and the result compared with offline manual measurement (MM) by a second blinded operator: Grade 1 uninterrupted fractionated activity (defined as segments > or =70 ms) for > or =70% of recording and uninterrupted > or =1 s; Grade 2 interrupted fractionated activity > or =70% of recording; Grade 3 intermittent fractionated activity 30-70%; Grade 4 discrete (<70 ms) complex electrogram (> or =5 direction changes); Grade 5 discrete simple electrograms (< or =4 direction changes); Grade 6 scar. Grade by VI and MM for 100 electrograms agreed in 89%. Five hundred electrograms were graded on Carto and NavX by VI to validate AUTO in (i) detection of CFE (grades 1-4 considered CFE), and (ii) assessing degree of fractionation by correlating grade and score by AUTO (data shown as sensitivity, specificity, r): NavX 'CFE mean' 92%, 91%, 0.56; Carto 'interval confidence level' using factory settings 89%, 62%, -0.72, and other published settings 80%, 74%, -0.65; Carto 'shortest confidence interval' 74%, 70%, 0.43; Carto 'average confidence interval' 86%, 66%, 0.53. Grading CFE by VI is accurate and correlates with AUTO.

  11. Atrial Electrogram Fractionation Distribution before and after Pulmonary Vein Isolation in Human Persistent Atrial Fibrillation-A Retrospective Multivariate Statistical Analysis.

    PubMed

    Almeida, Tiago P; Chu, Gavin S; Li, Xin; Dastagir, Nawshin; Tuan, Jiun H; Stafford, Peter J; Schlindwein, Fernando S; Ng, G André

    2017-01-01

    Purpose: Complex fractionated atrial electrograms (CFAE)-guided ablation after pulmonary vein isolation (PVI) has been used for persistent atrial fibrillation (persAF) therapy. This strategy has shown suboptimal outcomes due to, among other factors, undetected changes in the atrial tissue following PVI. In the present work, we investigate CFAE distribution before and after PVI in patients with persAF using a multivariate statistical model. Methods: 207 pairs of atrial electrograms (AEGs) were collected before and after PVI respectively, from corresponding LA regions in 18 persAF patients. Twelve attributes were measured from the AEGs, before and after PVI. Statistical models based on multivariate analysis of variance (MANOVA) and linear discriminant analysis (LDA) have been used to characterize the atrial regions and AEGs. Results: PVI significantly reduced CFAEs in the LA (70 vs. 40%; P < 0.0001). Four types of LA regions were identified, based on the AEGs characteristics: (i) fractionated before PVI that remained fractionated after PVI (31% of the collected points); (ii) fractionated that converted to normal (39%); (iii) normal prior to PVI that became fractionated (9%) and; (iv) normal that remained normal (21%). Individually, the attributes failed to distinguish these LA regions, but multivariate statistical models were effective in their discrimination ( P < 0.0001). Conclusion: Our results have unveiled that there are LA regions resistant to PVI, while others are affected by it. Although, traditional methods were unable to identify these different regions, the proposed multivariate statistical model discriminated LA regions resistant to PVI from those affected by it without prior ablation information.

  12. Wholly Patient-tailored Ablation of Atrial Fibrillation Guided by Spatio-Temporal Dispersion of Electrograms in the Absence of Pulmonary Veins Isolation

    PubMed Central

    Seitz, Julien; Bars, Clément; Théodore, Guillaume; Beurtheret, Sylvain; Lellouche, Nicolas; Bremondy, Michel; Ferracci, Ange; Faure, Jacques; Penaranda, Guillaume; Yamazaki, Masatoshi; Avula, Uma Mahesh R.; Curel, Laurence; Siame, Sabrina; Berenfeld, Omer; Pisapia, André; Kalifa, Jérôme

    2017-01-01

    Background The use of intra-cardiac electrograms to guide atrial fibrillation (AF) ablation has yielded conflicting results. We evaluated an electrogram marker of AF drivers: the clustering of electrograms exhibiting spatio-temporal dispersion — regardless of whether such electrograms were fractionated or not. Objective To evaluate the usefulness of spatio-temporal dispersion, a visually recognizable electric footprint of AF drivers, for the ablation of all forms of AF. Methods We prospectively enrolled 105 patients admitted for AF ablation. AF was sequentially mapped in both atria with a 20-pole PentaRay catheter. We tagged and ablated only regions displaying electrogram dispersion during AF. Results were compared to a validation set in which a conventional ablation approach was used (pulmonary vein isolation/stepwise approach). To establish the mechanism underlying spatio-temporal dispersion of AF electrograms, we conducted realistic numerical simulations of AF drivers in a 2-dimensional model and optical mapping of ovine atrial scar-related AF. Results Ablation at dispersion areas terminated AF in 95%. After ablation of 17±10% of the left atrial surface and 18 months of follow-up, the atrial arrhythmia recurrence rate was 15% after 1.4±0.5 procedure/patient vs 41% in the validation set after 1.5±0.5 procedure/patient (arrhythmia free-survival rates: 85% vs 59%, log rank P<0.001). In comparison with the validation set, radiofrequency times (49 ± 21 minutes vs 85 ± 34.5 minutes, p=0.001) and procedure times (168 ± 42 minutes vs. 230 ± 67 minutes, p<.0001) were shorter. In simulations and optical mapping experiments, virtual PentaRay recordings demonstrated that electrogram dispersion is mostly recorded in the vicinity of a driver. Conclusions The clustering of intra-cardiac electrograms exhibiting spatio-temporal dispersion is indicative of AF drivers. Their ablation allows for a non-extensive and patient-tailored approach to AF ablation. Clinical trial.gov number: NCT02093949 PMID:28104073

  13. Approaches to catheter ablation for persistent atrial fibrillation.

    PubMed

    Verma, Atul; Jiang, Chen-yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan

    2015-05-07

    Catheter ablation is less successful for persistent atrial fibrillation than for paroxysmal atrial fibrillation. Guidelines suggest that adjuvant substrate modification in addition to pulmonary-vein isolation is required in persistent atrial fibrillation. We randomly assigned 589 patients with persistent atrial fibrillation in a 1:4:4 ratio to ablation with pulmonary-vein isolation alone (67 patients), pulmonary-vein isolation plus ablation of electrograms showing complex fractionated activity (263 patients), or pulmonary-vein isolation plus additional linear ablation across the left atrial roof and mitral valve isthmus (259 patients). The duration of follow-up was 18 months. The primary end point was freedom from any documented recurrence of atrial fibrillation lasting longer than 30 seconds after a single ablation procedure. Procedure time was significantly shorter for pulmonary-vein isolation alone than for the other two procedures (P<0.001). After 18 months, 59% of patients assigned to pulmonary-vein isolation alone were free from recurrent atrial fibrillation, as compared with 49% of patients assigned to pulmonary-vein isolation plus complex electrogram ablation and 46% of patients assigned to pulmonary-vein isolation plus linear ablation (P=0.15). There were also no significant differences among the three groups for the secondary end points, including freedom from atrial fibrillation after two ablation procedures and freedom from any atrial arrhythmia. Complications included tamponade (three patients), stroke or transient ischemic attack (three patients), and atrioesophageal fistula (one patient). Among patients with persistent atrial fibrillation, we found no reduction in the rate of recurrent atrial fibrillation when either linear ablation or ablation of complex fractionated electrograms was performed in addition to pulmonary-vein isolation. (Funded by St. Jude Medical; ClinicalTrials.gov number, NCT01203748.).

  14. Panoramic Electrophysiological Mapping but not Electrogram Morphology Identifies Stable Sources for Human Atrial Fibrillation

    PubMed Central

    Narayan, Sanjiv M.; Shivkumar, Kalyanam; Krummen, David E.; Miller, John M.; Rappel, Wouter-Jan

    2013-01-01

    Background The foundation for successful arrhythmia ablation is the mapping of electric propagation to identify underlying mechanisms. In atrial fibrillation (AF), however, mapping is difficult so that ablation has often targeted electrogram features, with mixed results. We hypothesized that wide field-of-view (panoramic) mapping of both atria would identify causal mechanisms for AF and allow interpretation of local electrogram features, including complex fractionated atrial electrograms (CFAE). Methods and Results Contact mapping was performed using biatrial multipolar catheters in 36 AF subjects (29 persistent). Stable AF rotors (spiral waves) or focal sources were seen in 35 of 36 cases and targeted for ablation (focal impulse and rotor modulation) before pulmonary vein isolation. In 31 of 36 subjects (86.1%), AF acutely terminated (n=20; 16 to sinus rhythm) or organized (n=11; 19±8% slowing) with 2.5 minutes focal impulse and rotor modulation (interquartile range, 1.0–3.1) at one source, defined as the primary source. Subjects exhibited 2.1±1.0 concurrent AF sources of which the primary, by phase mapping, precessed in limited areas (persistent 2.5±1.7 versus paroxysmal 1.7±0.5 cm2; P=0.30). Notably, source regions showed mixed electrogram amplitudes and CFAE grades that did not differ from surrounding atrium (P=NS). AF sources were not consistently surrounded by CFAE (P=0.67). Conclusions Stable rotors and focal sources for human AF were revealed by contact panoramic mapping (focal impulse and rotor modulation mapping), but not by electrogram footprints. AF sources precessed within areas of ≈2 cm2, with diverse voltage characteristics poorly correlated with CFAE. Most CFAE sites lie remote from AF sources and are not suitable targets for catheter ablation of AF. PMID:23392583

  15. A novel intra-operative, high-resolution atrial mapping approach.

    PubMed

    Yaksh, Ameeta; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Oei, Frans B S; van de Woestijne, Pieter C; Bekkers, Jos A; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S

    2015-12-01

    A new technique is demonstrated for extensive high-resolution intra-operative atrial mapping that will facilitate the localization of atrial fibrillation (AF) sources and identification of the substrate perpetuating AF. Prior to the start of extra-corporal circulation, a 8 × 24-electrode array (2-mm inter-electrode distance) is placed subsequently on all the right and left epicardial atrial sites, including Bachmann's bundle, for recording of unipolar electrograms during sinus rhythm and (induced) AF. AF is induced by high-frequency pacing at the right atrial free wall. A pacemaker wire stitched to the right atrium serves as a reference signal. The indifferent pole is connected to a steal wire fixed to subcutaneous tissue. Electrograms are recorded by a computerized mapping system and, after amplification (gain 1000), filtering (bandwidth 0.5-400 Hz), sampling (1 kHz) and analogue to digital conversion (16 bits), automatically stored on hard disk. During the mapping procedure, real-time visualization secures electrogram quality. Analysis will be performed offline. This technique was performed in 168 patients of 18 years and older, with coronary and/or structural heart disease, with or without AF, electively scheduled for cardiac surgery and a ventricular ejection fraction above 40 %. The mean duration of the entire mapping procedure including preparation time was 9 ± 2 min. Complications related to the mapping procedure during or after cardiac surgery were not observed. We introduce the first epicardial atrial mapping approach with a high resolution of ≥1728 recording sites which can be performed in a procedure time of only 9±2 mins. This mapping technique can potentially identify areas responsible for initiation and persistence of AF and hopefully can individualize both diagnosis and therapy of AF.

  16. The modified stepwise ablation guided by low-dose ibutilide in chronic atrial fibrillation trial (The MAGIC-AF Study).

    PubMed

    Singh, Sheldon M; d'Avila, Andre; Kim, Young-Hoon; Aryana, Arash; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Barrett, Conor D; Heist, E Kevin; Parides, Michael K; Thorpe, Kevin E; Reddy, Vivek Y

    2016-05-21

    Complex fractionated atrial electrograms (CFAE) are targeted during persistent atrial fibrillation (AF) ablation. However, many CFAE sites are non-specific resulting in extensive ablation. Ibutilide has been shown to reduce left atrial surface area exhibiting CFAE. We hypothesized that ibutilide administration prior to CFAE ablation would identify sites critical for persistent AF maintenance allowing for improved procedural efficacy and long-term freedom from atrial arrhythmias. Two hundred patients undergoing a first-ever persistent AF catheter ablation procedure were randomly assigned to receive either 0.25 mg of intravenous ibutilide or saline placebo upon completion of pulmonary vein isolation. Complex fractionated atrial electrogram sites were then targeted with ablation. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Similar procedural characteristics (procedure, fluoroscopy, and ablation times) were observed with both strategies despite a greater reduction in left atrial surface area with CFAE sites (8 vs. 1%, P < 0.0001) and AF termination during CFAE ablation with ibutilide compared with placebo (75 vs. 57%, P = 0.007). The primary efficacy endpoint was achieved in 56% of patients receiving ibutilide and 49% receiving placebo (P = 0.35). No significant differences in peri-procedural complications were observed in both groups. Despite a reduction in CFAE area and greater AF termination during CFAE ablation, procedural characteristics and clinical outcomes were unchanged when CFAE ablation was guided by ibutilide administration. ClinicalTrials.gov number: NCT01014741. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  17. Electrogram Morphology Recurrence Patterns during Atrial Fibrillation

    PubMed Central

    Ng, Jason; Gordon, David; Passman, Rod S.; Knight, Bradley P.; Arora, Rishi; Goldberger, Jeffrey J.

    2014-01-01

    Background Traditional mapping of atrial fibrillation (AF) is limited by changing electrogram morphologies and variable cycle lengths. Objective We tested the hypothesis that morphology recurrence plot analysis would identify sites of stable and repeatable electrogram morphology patterns. Methods AF electrograms recorded from left atrial (LA) and right atrial (RA) sites in 19 patients (10 male, 59±10 years old) prior to AF ablation were analyzed. Morphology recurrence plots for each electrogram recording were created by cross-correlation of each automatically detected activation with every other activation in the recording. A recurrence percentage, the percentage of the most common morphology, and the mean cycle length of activations with the most common morphology (CLR) were computed. Results The morphology recurrence plots commonly showed checkerboard patterns of alternating high and low cross correlation values indicating periodic recurrences in morphologies. The mean recurrence percentage for all sites and all patients was 38±25%. The highest recurrence percentage per patient averaged 83±17%. The highest recurrence percentage was located in the RA in 5 patients and in the LA in 14 patients. Patients with sites of shortest CLR in the LA and RA had ablation failure rates of 25% and 100%, respectively (HR=4.95; p=0.05). Conclusions A new technique to characterize electrogram morphology recurrence demonstrated that there is a distribution of sites with high and low repeatability of electrogram morphologies. Sites with rapid activation of highly repetitive morphology patterns may be critical to sustaining AF. Further testing of this approach to map and ablate AF sources is warranted. PMID:25101485

  18. Prospective study of atrial fibrillation termination during ablation guided by automated detection of fractionated electrograms.

    PubMed

    Porter, Michael; Spear, William; Akar, Joseph G; Helms, Ray; Brysiewicz, Neil; Santucci, Peter; Wilber, David J

    2008-06-01

    Complex fractionated atrial electrograms (CFAE) may identify critical sites for perpetuation of atrial fibrillation (AF) and provide useful targets for ablation. Current assessment of CFAE is subjective; automated detection algorithms may improve reproducibility, but their utility in guiding ablation has not been tested. In 67 patients presenting for initial AF ablation (42 paroxysmal, 25 persistent), LA and CS mapping were performed during induced or spontaneous AF. CFAE were identified by an online automated computer algorithm and displayed on electroanatomical maps. A mean of 28 +/- 18 sites/patient were identified (20 +/- 13% of mapped sites), and were more frequent during persistent AF. CFAE occurred most commonly within the CS, on the atrial septum, and around the pulmonary veins. Ablation initially targeting CFAE terminated AF in 88% of paroxysmal AF, but only 20% of persistent AF (P < 0.001). Subsequently, additional ablation was performed in all patients (PV isolation for paroxysmal AF, PV isolation + mitral and roof lines for persistent AF). Minimum follow-up was 1 year. One-year freedom from recurrent atrial arrhythmias without antiarrhythmic drug therapy after a single procedure was 90% for paroxysmal AF, and 68% for persistent AF. Ablation guided by automated detection of CFAE proved feasible, and was associated with a high AF termination rate in paroxysmal, but not persistent AF. As an adjunct to conventional techniques, it was associated with excellent long-term single procedure outcomes in both groups. Criteria for identifying optimal CFAE sites for ablation, and selection of patients most likely to benefit, require additional study.

  19. Electrogram morphology recurrence patterns during atrial fibrillation.

    PubMed

    Ng, Jason; Gordon, David; Passman, Rod S; Knight, Bradley P; Arora, Rishi; Goldberger, Jeffrey J

    2014-11-01

    Traditional mapping of atrial fibrillation (AF) is limited by changing electrogram morphologies and variable cycle lengths. We tested the hypothesis that morphology recurrence plot analysis would identify sites of stable and repeatable electrogram morphology patterns. AF electrograms recorded from left atrial (LA) and right atrial (RA) sites in 19 patients (10 men; mean age 59 ± 10 years) before AF ablation were analyzed. Morphology recurrence plots for each electrogram recording were created by cross-correlation of each automatically detected activation with every other activation in the recording. A recurrence percentage, the percentage of the most common morphology, and the mean cycle length of activations with the most recurrent morphology were computed. The morphology recurrence plots commonly showed checkerboard patterns of alternating high and low cross-correlation values, indicating periodic recurrences in morphologies. The mean recurrence percentage for all sites and all patients was 38 ± 25%. The highest recurrence percentage per patient averaged 83 ± 17%. The highest recurrence percentage was located in the RA in 5 patients and in the LA in 14 patients. Patients with sites of shortest mean cycle length of activations with the most recurrent morphology in the LA and RA had ablation failure rates of 25% and 100%, respectively (hazard ratio 4.95; P = .05). A new technique to characterize electrogram morphology recurrence demonstrated that there is a distribution of sites with high and low repeatability of electrogram morphologies. Sites with rapid activation of highly repetitive morphology patterns may be critical to sustaining AF. Further testing of this approach to map and ablate AF sources is warranted. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Benefits of Atrial Substrate Modification Guided by Electrogram Similarity and Phase Mapping Techniques to Eliminate Rotors and Focal Sources Versus Conventional Defragmentation in Persistent Atrial Fibrillation.

    PubMed

    Lin, Yenn-Jiang; Lo, Men-Tzung; Chang, Shih-Lin; Lo, Li-Wei; Hu, Yu-Feng; Chao, Tze-Fan; Chung, Fa-Po; Liao, Jo-Nan; Lin, Chin-Yu; Kuo, Huan-Yu; Chang, Yi-Chung; Lin, Chen; Tuan, Ta-Chuan; Vincent Young, Hsu-Wen; Suenari, Kazuyoshi; Dan Do, Van Buu; Raharjo, Suunu Budhi; Huang, Norden E; Chen, Shih-Ann

    2016-11-01

    This prospective study compared the efficacy of atrial substrate modification guided by a nonlinear phase mapping technique with that of conventional substrate ablation. The optimal ablation strategy for persistent atrial fibrillation (AF) was unknown. In phase 1 study, we applied a cellular automation technique to simulate the electrical wave propagation to improve the phase mapping algorithm, involving analysis of high-similarity electrogram regions. In addition, we defined rotors and focal AF sources, using the physical parameters of the divergence and curvature forces. In phase 2 study, we enrolled 68 patients with persistent AF undergoing substrate modification into 2 groups, group-1 (n = 34) underwent similarity index (SI) and phase mapping techniques; group-2 (n = 34) received complex fractionated atrial electrogram ablation with commercially available software. Group-1 received real-time waveform similarity measurements in which a phase mapping algorithm was applied to localize the sources. We evaluated the single-procedure freedom from AF. In group-1, we identified an average of 2.6 ± 0.89 SI regions per chamber. These regions involved rotors and focal sources in 65% and 77% of patients in group-1, respectively. Group-1 patients had shorter ablation procedure times, higher termination rates, and significant reduction in AF recurrence compared to group-2 and a trend toward benefit for all atrial arrhythmias. Multivariate analysis showed that substrate mapping using nonlinear similarity and phase mapping was the independent predictor of freedom from AF recurrence (hazard ratio: 0.26; 95% confidence interval: 0.09 to 0.74; p = 0.01). Our study showed that for persistent AF ablation, a specified substrate modification guided by nonlinear phase mapping could eliminate localized re-entry and non-pulmonary focal sources after pulmonary vein isolation. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Stand-Alone Pulmonary Vein Isolation Versus Pulmonary Vein Isolation With Additional Substrate Modification as Index Ablation Procedures in Patients With Persistent and Long-Standing Persistent Atrial Fibrillation: The Randomized Alster-Lost-AF Trial (Ablation at St. Georg Hospital for Long-Standing Persistent Atrial Fibrillation).

    PubMed

    Fink, Thomas; Schlüter, Michael; Heeger, Christian-Hendrik; Lemes, Christine; Maurer, Tilman; Reissmann, Bruno; Riedl, Johannes; Rottner, Laura; Santoro, Francesco; Schmidt, Boris; Wohlmuth, Peter; Mathew, Shibu; Sohns, Christian; Ouyang, Feifan; Metzner, Andreas; Kuck, Karl-Heinz

    2017-07-01

    Pulmonary vein isolation (PVI) for persistent atrial fibrillation is associated with limited success rates and often requires multiple procedures to maintain stable sinus rhythm. In the prospective and randomized Alster-Lost-AF trial (Ablation at St. Georg Hospital for Long-Standing Persistent Atrial Fibrillation), we sought to assess, in patients with symptomatic persistent or long-standing persistent atrial fibrillation, the outcomes of initial ablative strategies comprising either stand-alone PVI (PVI-only approach) or a stepwise approach of PVI followed by complex fractionated atrial electrogram ablation and linear ablation (Substrate-modification approach). Patients were randomized 1:1 to stand-alone PVI or PVI plus substrate modification. The primary study end point was freedom from recurrence of any atrial tachyarrhythmia, outside a 90-day blanking period, at 12 months. A total of 124 patients were enrolled, with 118 patients included in the analysis (61 in the PVI-only group, 57 in the Substrate-modification group). Atrial tachyarrhythmias recurred in 28 PVI-only group patients and 24 Substrate-modification group patients, for 1-year freedom from tachyarrhythmia recurrence after a single ablation procedure of 54% (95% confidence interval, 43%-68%) in the PVI-only and 57% (95% confidence interval, 46%-72%) in the Substrate-modification group ( P =0.86). Twenty-four patients in the PVI-only group (39%) and 18 in the Substrate-modification group (32%) were without arrhythmia recurrence and off antiarrhythmic drug therapy at the end of the 12-month follow-up. In patients with persistent and long-standing persistent atrial fibrillation, no significant difference was observed in 12-month freedom from atrial tachyarrhythmias between an index ablative approach of stand-alone PVI and a stepwise approach of PVI plus complex fractionated atrial electrogram and linear ablation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00820625. © 2017 American Heart Association, Inc.

  2. A new transform for the analysis of complex fractionated atrial electrograms

    PubMed Central

    2011-01-01

    Background Representation of independent biophysical sources using Fourier analysis can be inefficient because the basis is sinusoidal and general. When complex fractionated atrial electrograms (CFAE) are acquired during atrial fibrillation (AF), the electrogram morphology depends on the mix of distinct nonsinusoidal generators. Identification of these generators using efficient methods of representation and comparison would be useful for targeting catheter ablation sites to prevent arrhythmia reinduction. Method A data-driven basis and transform is described which utilizes the ensemble average of signal segments to identify and distinguish CFAE morphologic components and frequencies. Calculation of the dominant frequency (DF) of actual CFAE, and identification of simulated independent generator frequencies and morphologies embedded in CFAE, is done using a total of 216 recordings from 10 paroxysmal and 10 persistent AF patients. The transform is tested versus Fourier analysis to detect spectral components in the presence of phase noise and interference. Correspondence is shown between ensemble basis vectors of highest power and corresponding synthetic drivers embedded in CFAE. Results The ensemble basis is orthogonal, and efficient for representation of CFAE components as compared with Fourier analysis (p ≤ 0.002). When three synthetic drivers with additive phase noise and interference were decomposed, the top three peaks in the ensemble power spectrum corresponded to the driver frequencies more closely as compared with top Fourier power spectrum peaks (p ≤ 0.005). The synthesized drivers with phase noise and interference were extractable from their corresponding ensemble basis with a mean error of less than 10%. Conclusions The new transform is able to efficiently identify CFAE features using DF calculation and by discerning morphologic differences. Unlike the Fourier transform method, it does not distort CFAE signals prior to analysis, and is relatively robust to jitter in periodic events. Thus the ensemble method can provide a useful alternative for quantitative characterization of CFAE during clinical study. PMID:21569421

  3. Quantitative Analysis of Localized Sources Identified by Focal Impulse and Rotor Modulation Mapping in Atrial Fibrillation

    PubMed Central

    Benharash, Peyman; Buch, Eric; Frank, Paul; Share, Michael; Tung, Roderick; Shivkumar, Kalyanam; Mandapati, Ravi

    2015-01-01

    Background New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM) mapping, and initial results reported with this technique have been favorable. We sought to independently evaluate the approach by analyzing quantitative characteristics of atrial electrograms used to identify rotors and describe acute procedural outcomes of FIRM-guided ablation. Methods and Results All FIRM-guided ablation procedures (n=24; 50% paroxysmal) at University of California, Los Angeles Medical Center were included for analysis. During AF, unipolar atrial electrograms collected from a 64-pole basket catheter were used to construct phase maps and identify putative AF sources. These sites were targeted for ablation, in conjunction with pulmonary vein isolation in most patients (n=19; 79%). All patients had rotors identified (mean, 2.3±0.9 per patient; 72% in left atrium). Prespecified acute procedural end point was achieved in 12 of 24 (50%) patients: AF termination (n=1), organization (n=3), or >10% slowing of AF cycle length (n=8). Basket electrodes were within 1 cm of 54% of left atrial surface area, and a mean of 31 electrodes per patient showed interpretable atrial electrograms. Offline analysis revealed no differences between rotor and distant sites in dominant frequency or Shannon entropy. Electroanatomic mapping showed no rotational activation at FIRM-identified rotor sites in 23 of 24 patients (96%). Conclusions FIRM-identified rotor sites did not exhibit quantitative atrial electrogram characteristics expected from rotors and did not differ quantitatively from surrounding tissue. Catheter ablation at these sites, in conjunction with pulmonary vein isolation, resulted in AF termination or organization in a minority of patients (4/24; 17%). Further validation of this approach is necessary. PMID:25873718

  4. Mechanistic Comparison of "Nearly Missed" Versus "On-Target" Rotor Ablation.

    PubMed

    Yamazaki, Masatoshi; Avula, Uma Mahesh R; Berenfeld, Omer; Kalifa, Jérôme

    2015-08-01

    This study used advanced optical mapping techniques to examine atrial fibrillation (AF) dynamics before and after 2 distinct electrogram-based ablation strategies: complex fractionated atrial electrograms (CFAEs) and DFmax/rotor ablation. Among the electrogram analytical features proposed to unravel the atrial regions that perpetuate AF, CFAEs, highest dominant frequency sites (DFmax), and, more recently, phase analysis-enabled rotor mapping have received the largest attention. Still, the mechanisms by which these approaches modulate AF dynamics and lead to AF termination are unknown. In Langendorff-perfused sheep hearts, AF was maintained by the continuous perfusion of acetylcholine and high-resolution endocardial-epicardial optical videos were recorded from the left atrial free wall and the posterior left atrium. Then, DFmax/rotor regions (n = 7), or CFAE regions harboring the highest wavebreak density (HWD) (n = 5), were targeted with a 4F ablation catheter (5 to 15 W, 30 to 60 s/point). Thereafter, we examined the changes in AF dynamics and whether AF terminated. DFmax/rotor point ablation resulted in a significant decrease in DFmax values. In 2 animals AF terminated, whereas in the remaining 5 animals the post-ablation DFmax domain remained in the vicinity of its pre-ablation location. However, after HWD/CFAEs density ablation, DFmax values did not change, AF did not terminate, and post-ablation DFmax domains relocated from the left atrial free wall to the pulmonary vein-posterior left atrium region. In another group of hearts (n = 12), we observed that upon a progressive increase in acetylcholine concentration-mimicking the acute electrophysiological changes occurring after ablation-3-dimensional rotors drifted from one atrial region to another along large gradients of myocardial thickness. "On-target" DFmax/rotor ablation leads to the annihilation of the fibrillation-driving rotor. This translates into large decreases in AF frequency or AF termination. In contrast, "nearly missed" HWD/CFAEs ablation spares the fibrillation-driving rotor, and set the stage for rotor drift along large myocardial thickness gradients. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    PubMed

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  6. Randomized ablation strategies for the treatment of persistent atrial fibrillation: RASTA study.

    PubMed

    Dixit, Sanjay; Marchlinski, Francis E; Lin, David; Callans, David J; Bala, Rupa; Riley, Michael P; Garcia, Fermin C; Hutchinson, Mathew D; Ratcliffe, Sarah J; Cooper, Joshua M; Verdino, Ralph J; Patel, Vickas V; Zado, Erica S; Cash, Nancy R; Killian, Tony; Tomson, Todd T; Gerstenfeld, Edward P

    2012-04-01

    The single-procedure efficacy of pulmonary vein isolation (PVI) is less than optimal in patients with persistent atrial fibrillation (AF). Adjunctive techniques have been developed to enhance single-procedure efficacy in these patients. We conducted a study to compare 3 ablation strategies in patients with persistent AF. Subjects were randomized as follows: arm 1, PVI + ablation of non-PV triggers identified using a stimulation protocol (standard approach); arm 2, standard approach + empirical ablation at common non-PV AF trigger sites (mitral annulus, fossa ovalis, eustachian ridge, crista terminalis, and superior vena cava); or arm 3, standard approach + ablation of left atrial complex fractionated electrogram sites. Patients were seen at 6 weeks, 6 months, and 1 year; transtelephonic monitoring was performed at each visit. Antiarrhythmic drugs were discontinued at 3 to 6 months. The primary study end point was freedom from atrial arrhythmias off antiarrhythmic drugs at 1 year after a single-ablation procedure. A total of 156 patients (aged 59±9 years; 136 males; AF duration, 47±50 months) participated (arm 1, 55 patients; arm 2, 50 patients; arm 3, 51 patients). Procedural outcomes (procedure, fluoroscopy, and PVI times) were comparable between the 3 arms. More lesions were required to target non-PV trigger sites than a complex fractionated electrogram (33±9 versus 22±9; P<0.001). The primary end point was achieved in 71 patients and was worse in arm 3 (29%) compared with arm 1 (49%; P=0.04) and arm 2 (58%; P=0.004). These data suggest that additional substrate modification beyond PVI does not improve single-procedure efficacy in patients with persistent AF. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00379301.

  7. Value of local electrogram characteristics predicting successful catheter ablation of left-versus right-sided accessory atrioventricular pathways by radiofrequency current.

    PubMed

    Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P

    1995-01-01

    Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval < or = 50 ms, electrogram stability (left-sided targets only), retrograde accessory pathway potential (right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.

  8. Behavior of an Automatic Pacemaker Sensing Algorithm for Single-Pass VDD Atrial Electrograms

    DTIC Science & Technology

    2001-10-25

    830- s lead (Medico), during several different body postures, deep respiration, and walking. The algorithm had a pre - determined sensing dynamic range...SINGLE-PASS VDD ATRIAL ELECTROGRAMS J. Kim1, S.H. Lee1, S.Y.Yang2, B. S . Cho2, and W. Huh1 1Department of Electronics Engineering, Myongji...University, Yongin, Korea 2Department of Information and Communication, Dongwon College, Kwangju, Korea S T = 5 0 % x ( B + C ) / 2 S T = 5 0 % x ( A + B

  9. An unusual tachycardia.

    PubMed

    Hanon, Sam; Shapiro, Michael; Schweitzer, Paul

    2004-07-01

    The following article presents an unusual case of atrial tachycardia, initially misdiagnosed due to a lack of clear P waves. The diagnosis was eventually confirmed using the atrial electrogram from the patient's pacemaker.

  10. Atrial electrogram interpretation improves after an innovative education program.

    PubMed

    Preston, Julie L; Currey, Judy; Considine, Julie

    2015-01-01

    To avoid adverse patient outcomes from inappropriate treatment, it is recommended that an atrial electrogram (AEG) be recorded whenever atrial arrhythmias develop in patients after cardiac surgery. However, AEGs are not commonly performed because nurses lack knowledge about differentiating atrial rhythms on AEGs. To investigate whether completing a novel online evidence-based education program on interpreting AEGs would improve critical care nurses' AEG interpretation. Specialized critical care nurses were taught about obtaining and interpreting atrial rhythms on AEGs using a 42-minute online mini-movie. AEG interpretation was assessed pre and two and eight weeks post-intervention. AEG interpretation increased two weeks post intervention and was retained at eight weeks. Some participants used this newly acquired knowledge to interpret arrhythmias that were not taught during the education program. Accurate interpretation of AEGs is an easy skill for specialized critical care nurses to learn via an online education program.

  11. Insights into new-onset atrial fibrillation following open heart surgery and implications for type II atrial flutter.

    PubMed

    Sadrpour, Shervin A; Srinivasan, Deepa; Bhimani, Ashish A; Lee, Seungyup; Ryu, Kyungmoo; Cakulev, Ivan; Khrestian, Celeen M; Markowitz, Alan H; Waldo, Albert L; Sahadevan, Jayakumar

    2015-12-01

    Postoperative atrial fibrillation (POAF), new-onset AF after open heart surgery (OHS), is thought to be related to pericarditis. Based on AF studies in the canine sterile pericarditis model, we hypothesized that POAF in patients after OHS may be associated with a rapid, regular rhythm in the left atrium (LA), suggestive of an LA driver maintaining AF. The aim of this study was to test the hypothesis that in patients with POAF, atrial electrograms (AEGs) recorded from at least one of the two carefully selected LA sites would manifest a rapid, regular rhythm with AEGs of short cycle length (CL) and constant morphology, but a selected right atrial (RA) site would manifest AEGs with irregular CLs and variable morphology. In 44 patients undergoing OHS, AEGs recorded from the epicardial surface of the RA, the LA portion of Bachmann's bundle, and the posterior LA during sustained AF were analysed for regularity of CL and morphology. Sustained AF occurred in 15 of 44 patients. Atrial electrograms were recorded in 11 of 15 patients; 8 of 11 had rapid, regular activation with constant morphology recorded from at least one LA site; no regular AEG sites were present in 3 of 11 patients. Atrial electrograms recorded during sustained POAF frequently demonstrated rapid, regular activation in at least one LA site, consistent with a driver maintaining AF. Published by Oxford University Press on behalf of the European Society of Cardiology 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  12. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    PubMed

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length <300 ms). Intermittent sensing of far-field R waves during sinus tachycardia caused 27 inappropriate AT/AF detections; these detections lasted 2.6+/-2.0 minutes. AT/AF was detected continuously in 27 of 28 patients who had spontaneous episodes of AT/AF (96%). The device memory recorded 90 appropriate AT/AF episodes lasting >1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  13. Influence of detomidine on atrial fibrillation cycle length measured by intracardiac electrogram recording and by colour tissue Doppler imaging in horses.

    PubMed

    Decloedt, A; de Clercq, D; van der Vekens, N; Verheyen, T; Ven, S; van Loon, G

    2016-01-01

    Shortening of atrial fibrillation cycle length (AFCL) is a marker of atrial electrical remodelling due to atrial fibrillation (AF). To investigate the effect of administration of detomidine on AFCL measured invasively from an intra-atrial electrogram (AFCLEGM) and noninvasively by tissue Doppler imaging (AFCLTDI). We hypothesised that detomidine would have no effect on AFCL but would improve the ease of TDI measurements and facilitate noninvasive AFCL determination. Prospective clinical study. Measurements were performed before and after i.v. administration of 7.5 μg/kg bwt detomidine in 33 episodes of AF in 32 horses (582 ± 64 kg bwt, 10 ± 3 years old) referred for electrical cardioversion. The AFCLEGM was measured from a right atrial intracardiac electrogram. The AFCLTDI was measured from atrial colour tissue velocity curves in 5 atrial wall regions. Mean AFCLEGM and AFCLTDI without and with sedation were compared using a repeated-measures linear mixed model with Bonferroni correction for multiple comparisons and calculation of the Bland-Altman mean bias and limits of agreement between AFCLEGM and AFCLTDI. The mean AFCL was significantly increased after sedation, but this increase was very small (mean difference +4 ms). For AFCLTDI measurements, sedation significantly improved the quality of the atrial myocardial velocity curves and the number of AF cycles that could be measured per cardiac cycle. The Bland-Altman bias between AFCLEGM without sedation and AFCLTDI with sedation ranged from -18 to +15 ms depending on wall region. Bland-Altman limits of agreement were similar between AFCLEGM without sedation and AFCLTDI without and with sedation. Therefore, noninvasive AFCLTDI measurements with sedation can be used to estimate the atrial fibrillatory rate. Sedation facilitates noninvasive AFCL measurements but causes a slight increase in AFCL. Noninvasive AFCL measurements can be used as an indicator of atrial electrical remodelling, to study AF pathophysiology and to investigate the effect of anti-arrhythmic drugs. © 2014 EVJ Ltd.

  14. Machine learning methods for locating re-entrant drivers from electrograms in a model of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    McGillivray, Max Falkenberg; Cheng, William; Peters, Nicholas S.; Christensen, Kim

    2018-04-01

    Mapping resolution has recently been identified as a key limitation in successfully locating the drivers of atrial fibrillation (AF). Using a simple cellular automata model of AF, we demonstrate a method by which re-entrant drivers can be located quickly and accurately using a collection of indirect electrogram measurements. The method proposed employs simple, out-of-the-box machine learning algorithms to correlate characteristic electrogram gradients with the displacement of an electrogram recording from a re-entrant driver. Such a method is less sensitive to local fluctuations in electrical activity. As a result, the method successfully locates 95.4% of drivers in tissues containing a single driver, and 95.1% (92.6%) for the first (second) driver in tissues containing two drivers of AF. Additionally, we demonstrate how the technique can be applied to tissues with an arbitrary number of drivers. In its current form, the techniques presented are not refined enough for a clinical setting. However, the methods proposed offer a promising path for future investigations aimed at improving targeted ablation for AF.

  15. Intravenous sotalol decreases transthoracic cardioversion energy requirement for chronic atrial fibrillation in humans: assessment of the electrophysiological effects by biatrial basket electrodes.

    PubMed

    Lai, L P; Lin, J L; Lien, W P; Tseng, Y Z; Huang, S K

    2000-05-01

    This study was undertaken to assess the effects of sotalol on the transthoracic cardioversion energy requirement for chronic atrial fibrillation (AF) and on the atrial electrograms during AF recorded by two basket electrodes. The effects of sotalol infusion on transthoracic electrical cardioversion for chronic atrial fibrillation in humans have not been well investigated. We included 18 patients with persistent AF for more than three months. Atrial electrograms were recorded by two basket electrodes positioned in each atrium respectively. Transthoracic cardioversion was performed before and after sotalol 1.5 mg/kg i.v. infusion. In the 14 patients whose AF could be terminated by cardioversion before sotalol infusion, the atrial defibrillation energy was significantly reduced after sotalol infusion (236 +/- 74 jules [J] vs. 186 +/- 77 J; p < 0.01). Atrial fibrillation was refractory to cardioversion in four patients at baseline and was converted to sinus rhythm by cardioversion after sotalol infusion in two of them. We further divided the patients into two groups. Group A consisted of 10 patients in whom the energy requirement was decreased by sotalol while group B consisted of eight patients in whom the energy requirement was not decreased. The mean A-A (atrial local electrogram) intervals during AF were significantly increased after sotalol infusion in both groups, but the increment of A-A interval was significantly larger in group A than it was in group B patients (36 +/- 13 ms vs. 22 +/- 8 ms for the right atrium; 19 +/- 7 ms vs. 9 +/- 7 ms for the left atrium; both p < 0.05). The spatial and temporal dispersions of A-A intervals were not significantly changed after sotalol infusion in both atria in both groups. Sotalol decreases the atrial defibrillation energy requirement by increasing atrial refractoriness but not by decreasing the dispersion of refractoriness.

  16. Elimination of the negative component of the unipolar atrial electrogram as an in vivo marker of transmural lesion creation: acute study in canines.

    PubMed

    Bortone, Agustín; Brault-Noble, Guillaume; Appetiti, Anthony; Marijon, Eloi

    2015-08-01

    It has been experimentally shown that elimination of the negative component of the unipolar atrial electrogram (R morphology completion) during radiofrequency applications reflects transmural lesions creation. Subsequently, it has been clinically suggested that such a transmurality can be either irreversible or reversible. The present study is aimed to determine, at the histological level, whether transmural lesions, assessed by R morphology completion, might indeed be reversible in some circumstances or not. In 6 Mongrel hound dogs, superior and inferior vena cavae were isolated and individual lesions were created in the right atrium using radiofrequency energy (30 W/48°C/17 mL/min as presettings and 10g of force in average) under CARTO guidance. Five types of lesions were created; R+0: termination of ablation at the time of R morphology completion; R+5, R+10, or R+20: extension of ablation for 5, 10, or 20 seconds, respectively, after R morphology achievement; and conventional: radiofrequency applications lasting 30 seconds irrespective of the atrial electrogram modification. All conventional, R+5, R+10, and R+20 lesions were necrotic and transmural, whereas some R+0 lesions were not (comprising a part of necrosis and a part of reversible cell damage). Interestingly, surrounding organ injuries were observed after conventional, R+10, and R+20 radiofrequency applications but were not observed after R+0 and R+5 applications. Elimination of the negative component of the unipolar atrial electrogram reflects, in general, irreversible transmural necrosis creation. In some cases, however, it translates transmural lesion only (with potential reversibility) likely related to transient cell damage creation. © 2015 American Heart Association, Inc.

  17. [Impact of CHA2DS2 VASc score on substrate for persistent atrial fibrillation and outcome post catheter ablation of atrial fibrillation].

    PubMed

    Ribo, Tang; Jianzeng, Dong; Xiaohui, Liu; Meisheng, Shang; Ronghui, Yu; Deyong, Long; Xin, Du; Junping, Kang; Jiahui, Wu; Man, Ning; Caihua, Sang; Chenxi, Jiang; Rong, Bai; Songnan, Li; Yan, Yao; Songnan, Wen; Changsheng, Ma

    2015-08-01

    To explore if CHA2DS2 VASc score can predict substrate for persistent atrial fibrillation ( AF) and outcome post catheter ablation of AF. From January 2011 to December 2012,116 patients underwent catheter ablation of persistent AF in our department and were enrolled in this study. CHA2DS2VASc score was calculated as follows: two points were assigned for a history of stroke or transient ischemic attack and age ≥ 75 and 1 point each was assigned for age ≥ 65, a history of hypertension, diabetes,recent cardiac failure, vessel disease, female. Left atrial geometry ( LA) was reconstructed with a 3.5 mm tip ablation catheter with fill-in threshold 10 in CARTO system. The mapping catheter was stabled at each endocardial location for at least 3 seconds for recording. The electrogram recordings at each endocardial location were analyzed with a custom software embedded in the CARTO mapping system. Interval confidence level (ICL) was used to characterize complex fractionated atrial electrograms (CFAEs) . As the default setting of the software, ICL more than or equal to 7 was considered sites with a highly repetitive CFAEs complex. CFAEs index was defined as the fraction of area of ICL more than or equal to 7 to the left atrial surface. The CFAEs index and outcome of catheter ablation among different CHA2DS2VASc groups were compared. Of the 116 patients, CHA2DS2VASc was 0 in 33 patients, 1 in 31 patients and ≥ 2 in 52 patients. Left atrial surface ((121.2 ± 18.9) cm2, (133.6 ± 23.8) cm2, (133.9 ± 16.1) cm2, P = 0.008), left atrial volume ((103.6 ± 24.8) ml, (118.3 ± 27.8) ml, (120.9 ± 20.9) ml, P = 0.005) and CFAEs index (44.6% ± 22.4%, 54.2% ± 22.2%, 58.7% ± 23.1%, P = 0.023) increased in proportion with increasing CHA2DS2VASc. ICLmax, ICLmin and CFAEs spatial distribution were similar among the three groups. During the mean follow-up of (13 ± 8) months, the recurrence rate were 36.4%, 35.5%, 55.8% among the three groups (P = 0.025). A high CHA2DS2VASc score is associated with extensive AF substrate and higher recurrence rate post catheter ablation of persistent AF.

  18. Simultaneous Biatrial High-Density (510-512 Electrodes) Epicardial Mapping of Persistent and Long-Standing Persistent Atrial Fibrillation in Patients: New Insights Into the Mechanism of Its Maintenance.

    PubMed

    Lee, Seungyup; Sahadevan, Jayakumar; Khrestian, Celeen M; Cakulev, Ivan; Markowitz, Alan; Waldo, Albert L

    2015-12-01

    The mechanism(s) of persistent and long-standing persistent (LSP) atrial fibrillation (AF) is/are poorly understood. We performed high-density, simultaneous, biatrial, epicardial mapping of persistent and LSP AF in patients undergoing open heart surgery (1) to test the hypothesis that persistent and LSP AF are due to ≥ 1 drivers, either focal or reentrant, and (2) to characterize associated atrial activation. Twelve patients with persistent and LSP AF (1 month to 9 years duration) were studied at open heart surgery. During AF, electrograms were recorded from both atria simultaneously for 1 to 5 minutes from 510 to 512 epicardial electrodes with ECG lead II. Thirty-two consecutive seconds of activation sequence maps were produced per patient. During AF, multiple foci (QS unipolar atrial electrograms) of different cycle lengths (mean, 175 ± 18 ms) were present in both atria in 11 of 12 patients. Foci (2-4 per patient, duration 5-32 s) were either sustained or intermittent, were predominantly found in the lateral left atrial free wall, and likely acted as drivers. Random and nonrandom breakthrough activation sites (initial r or R in unipolar atrial electrograms) were also found. In 1 of 12 patients, only breakthrough sites were found. All wave fronts emanated from foci and breakthrough sites, and largely either collided or merged with each other at variable sites. Repetitive focal QS activation occasionally generated repetitive wannabe reentrant activation in 5 of 12 patients. No actual reentry was found. During persistent and LSP AF in 12 patients, wave fronts emanating from foci and breakthrough sites maintained AF. No reentry was demonstrated. © 2015 American Heart Association, Inc.

  19. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    PubMed

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P < .001), but there was substantial overlap with pace capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential ablation line correlates with entrance block in 95% of vein pairs and can be achieved without circular mapping catheter guidance. Thus, pace capture along the ablation line can be used to identify conduction gaps. Interestingly, more RF ablation energy was required to achieve loss of pace capture along the ablation line than for entrance block into PVs. Further study is warranted to determine whether this method results in more durable ablation lesions that reduce recurrence of AF. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Prevalence and mechanism of rotor activation identified during atrial fibrillation by noncontact mapping: Lack of evidence for a role in the maintenance of atrial fibrillation.

    PubMed

    Yamabe, Hiroshige; Kanazawa, Hisanori; Ito, Miwa; Kaneko, Shozo; Ogawa, Hisao

    2016-12-01

    It remains unclear whether atrial fibrillation (AF) is maintained by the rotor. We evaluated the role of the rotor and examined its mechanism. Among 75 patients with AF (60 paroxysmal, 15 persistent AF) who underwent 3-dimensional noncontact left atrial mapping during AF, we examined the prevalence and location of rotor activation and elucidated its mechanism. Catheter ablation was performed in a stepwise fashion (linear roof lesion and complex fractionated atrial electrogram ablation after pulmonary vein [PV) isolation) until AF termination. Rotor activation was observed in 11 patients (14.7%; 10 paroxysmal and 1 persistent AF) (tachycardia cycle length 160.0 ± 19.8 ms). Rotors were observed transiently (duration 6128 ± 9094 ms) during AF at the roof (n = 5), septum (n = 3), and ostium of the left superior PV (n = 3). Five rotors circulated in clockwise and 6 in counterclockwise directions. The length of the block line at the center of the rotor was 15.2 ± 6.9 mm. The electrograms at the block line showed low-amplitude multiple deflections (n = 7) or double potentials (n = 4), and the amplitudes during rotor activation were significantly lower than those during sinus rhythm (0.27 ± 0.18 mV vs 1.22 ± 0.92 mV; P < .01). No conduction disturbances were found during sinus rhythm, suggesting that the central line of block was formed functionally. AF was terminated by PV isolation alone without additional lesions in patients with rotors. Functionally formed rotor activation was observed during AF in a limited number of patients. These rotor activations may not be related to AF maintenance, but rather may reflect a transient organization of random propagation. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Impact of stepwise ablation on the biatrial substrate in patients with persistent atrial fibrillation and heart failure.

    PubMed

    Jones, David G; Haldar, Shouvik K; Jarman, Julian W E; Johar, Sofian; Hussain, Wajid; Markides, Vias; Wong, Tom

    2013-08-01

    Ablation of persistent atrial fibrillation can be challenging, often involving not only pulmonary vein isolation (PVI) but also additional linear lesions and ablation of complex fractionated electrograms (CFE). We examined the impact of stepwise ablation on a human model of advanced atrial substrate of persistent atrial fibrillation in heart failure. In 30 patients with persistent atrial fibrillation and left ventricular ejection fraction ≤35%, high-density CFE maps were recorded biatrially at baseline, in the left atrium (LA) after PVI and linear lesions (roof and mitral isthmus), and biatrially after LA CFE ablation. Surface area of CFE (mean cycle length ≤120 ms) remote to PVI and linear lesions, defined as CFE area, was reduced after PVI (18.3±12.03 to 10.2±7.1 cm(2); P<0.001) and again after linear lesions (7.7±6.5 cm(2); P=0.006). Complete mitral isthmus block predicted greater CFE reduction (P=0.02). Right atrial CFE area was reduced by LA ablation, from 25.9±14.1 to 12.9±11.8 cm(2) (P<0.001). Estimated 1-year arrhythmia-free survival was 72% after a single procedure. Incomplete linear lesion block was an independent predictor of arrhythmia recurrence (hazard ratio, 4.69; 95% confidence interval, 1.05-21.06; P=0.04). Remote LA CFE area was progressively reduced following PVI and linear lesions, and LA ablation reduced right atrial CFE area. Reduction of CFE area at sites remote from ablation would suggest either regression of the advanced atrial substrate or that these CFE were functional phenomena. Nevertheless, in an advanced atrial fibrillation substrate, linear lesions after PVI diminished the target area for CFE ablation, and complete lesions resulted in a favorable clinical outcome.

  2. Computationally efficient method for localizing the spiral rotor source using synthetic intracardiac electrograms during atrial fibrillation.

    PubMed

    Shariat, M H; Gazor, S; Redfearn, D

    2015-08-01

    Atrial fibrillation (AF), the most common sustained cardiac arrhythmia, is an extremely costly public health problem. Catheter-based ablation is a common minimally invasive procedure to treat AF. Contemporary mapping methods are highly dependent on the accuracy of anatomic localization of rotor sources within the atria. In this paper, using simulated atrial intracardiac electrograms (IEGMs) during AF, we propose a computationally efficient method for localizing the tip of the electrical rotor with an Archimedean/arithmetic spiral wavefront. The proposed method deploys the locations of electrodes of a catheter and their IEGMs activation times to estimate the unknown parameters of the spiral wavefront including its tip location. The proposed method is able to localize the spiral as soon as the wave hits three electrodes of the catheter. Our simulation results show that the method can efficiently localize the spiral wavefront that rotates either clockwise or counterclockwise.

  3. Spiral wave classification using normalized compression distance: Towards atrial tissue spatiotemporal electrophysiological behavior characterization.

    PubMed

    Alagoz, Celal; Guez, Allon; Cohen, Andrew; Bullinga, John R

    2015-08-01

    Analysis of electrical activation patterns such as re-entries during atrial fibrillation (Afib) is crucial in understanding arrhythmic mechanisms and assessment of diagnostic measures. Spiral waves are a phenomena that provide intuitive basis for re-entries occurring in cardiac tissue. Distinct spiral wave behaviors such as stable spiral waves, meandering spiral waves, and spiral wave break-up may have distinct electrogram manifestations on a mapping catheter. Hence, it is desirable to have an automated classification of spiral wave behavior based on catheter recordings for a qualitative characterization of spatiotemporal electrophysiological activity on atrial tissue. In this study, we propose a method for classification of spatiotemporal characteristics of simulated atrial activation patterns in terms of distinct spiral wave behaviors during Afib using two different techniques: normalized compressed distance (NCD) and normalized FFT (NFFTD). We use a phenomenological model for cardiac electrical propagation to produce various simulated spiral wave behaviors on a 2D grid and labeled them as stable, meandering, or breakup. By mimicking commonly used catheter types, a star shaped and a circular shaped both of which do the local readings from atrial wall, monopolar and bipolar intracardiac electrograms are simulated. Virtual catheters are positioned at different locations on the grid. The classification performance for different catheter locations, types and for monopolar or bipolar readings were also compared. We observed that the performance for each case differed slightly. However, we found that NCD performance is superior to NFFTD. Through the simulation study, we showed the theoretical validation of the proposed method. Our findings suggest that a qualitative wavefront activation pattern can be assessed during Afib without the need for highly invasive mapping techniques such as multisite simultaneous electrogram recordings.

  4. Ablation of Persistent Atrial Fibrillation Targeting Low-Voltage Areas With Selective Activation Characteristics.

    PubMed

    Jadidi, Amir S; Lehrmann, Heiko; Keyl, Cornelius; Sorrel, Jérémie; Markstein, Viktor; Minners, Jan; Park, Chan-Il; Denis, Arnaud; Jaïs, Pierre; Hocini, Mélèze; Potocnik, Clemens; Allgeier, Juergen; Hochholzer, Willibald; Herrera-Sidloky, Claudia; Kim, Steve; Omri, Youssef El; Neumann, Franz-Josef; Weber, Reinhold; Haïssaguerre, Michel; Arentz, Thomas

    2016-03-01

    Complex-fractionated atrial electrograms and atrial fibrosis are associated with maintenance of persistent atrial fibrillation (AF). We hypothesized that pulmonary vein isolation (PVI) plus ablation of selective atrial low-voltage sites may be more successful than PVI only. A total of 85 consecutive patients with persistent AF underwent high-density atrial voltage mapping, PVI, and ablation at low-voltage areas (LVA < 0.5 mV in AF) associated with electric activity lasting > 70% of AF cycle length on a single electrode (fractionated activity) or multiple electrodes around the circumferential mapping catheter (rotational activity) or discrete rapid local activity (group I). The procedural end point was AF termination. Arrhythmia freedom was compared with a control group (66 patients) undergoing PVI only (group II). PVI alone was performed in 23 of 85 (27%) patients of group I with low amount (< 10% of left atrial surface area) of atrial low voltage. Selective atrial ablation in addition to PVI was performed in 62 patients with termination of AF in 45 (73%) after 11 ± 9 minutes radiofrequency delivery. AF-termination sites colocalized within LVA in 80% and at border zones in 20%. Single-procedural arrhythmia freedom at 13 months median follow-up was achieved in 59 of 85 (69%) patients in group I, which was significantly higher than the matched control group (31/66 [47%], P < 0.001). There was no significant difference in the success rate of patients in group I with a low amount of low voltage undergoing PVI only and patients requiring PVI+selective low-voltage ablation (P = 0.42). Ablation of sites with distinct activation characteristics within/at borderzones of LVA in addition to PVI is more effective than conventional PVI-only strategy for persistent AF. PVI only seems to be sufficient to treat patients with left atrial low voltage < 10%. © 2016 American Heart Association, Inc.

  5. A flash from the past: a case on long term follow-up of a "corridor" operation.

    PubMed

    Ricciardi, Danilo; Sarkozy, Andrea; Wauters, Kristel; Brugada, Pedro

    2013-01-01

    An electrophysiological study in a patient with a previous corridor operation was performed because of syncope. The atrial electrograms showed the persistence of the sinus rhythm in the right atrial corridor despite an organized atrial fibrillation in the left atrium. The first case described of a long term follow-up in a corridor operation, one of the first described surgical approach for the treatment of atrial fibrillation, that gave the beginning to the non-pharmacological approach of this arrhythmia. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Comparison of spectral estimators for characterizing fractionated atrial electrograms

    PubMed Central

    2013-01-01

    Background Complex fractionated atrial electrograms (CFAE) acquired during atrial fibrillation (AF) are commonly assessed using the discrete Fourier transform (DFT), but this can lead to inaccuracy. In this study, spectral estimators derived by averaging the autocorrelation function at lags were compared to the DFT. Method Bipolar CFAE of at least 16 s duration were obtained from pulmonary vein ostia and left atrial free wall sites (9 paroxysmal and 10 persistent AF patients). Power spectra were computed using the DFT and three other methods: 1. a novel spectral estimator based on signal averaging (NSE), 2. the NSE with harmonic removal (NSH), and 3. the autocorrelation function average at lags (AFA). Three spectral parameters were calculated: 1. the largest fundamental spectral peak, known as the dominant frequency (DF), 2. the DF amplitude (DA), and 3. the mean spectral profile (MP), which quantifies noise floor level. For each spectral estimator and parameter, the significance of the difference between paroxysmal and persistent AF was determined. Results For all estimators, mean DA and mean DF values were higher in persistent AF, while the mean MP value was higher in paroxysmal AF. The differences in means between paroxysmals and persistents were highly significant for 3/3 NSE and NSH measurements and for 2/3 DFT and AFA measurements (p<0.001). For all estimators, the standard deviation in DA and MP values were higher in persistent AF, while the standard deviation in DF value was higher in paroxysmal AF. Differences in standard deviations between paroxysmals and persistents were highly significant in 2/3 NSE and NSH measurements, in 1/3 AFA measurements, and in 0/3 DFT measurements. Conclusions Measurements made from all four spectral estimators were in agreement as to whether the means and standard deviations in three spectral parameters were greater in CFAEs acquired from paroxysmal or in persistent AF patients. Since the measurements were consistent, use of two or more of these estimators for power spectral analysis can be assistive to evaluate CFAE more objectively and accurately, which may lead to improved clinical outcome. Since the most significant differences overall were achieved using the NSE and NSH estimators, parameters measured from their spectra will likely be the most useful for detecting and discerning electrophysiologic differences in the AF substrate based upon frequency analysis of CFAE. PMID:23855345

  7. Origin and characteristics of high Shannon entropy at the pivot of locally stable rotors: insights from computational simulation.

    PubMed

    Ganesan, Anand N; Kuklik, Pawel; Gharaviri, Ali; Brooks, Anthony; Chapman, Darius; Lau, Dennis H; Roberts-Thomson, Kurt C; Sanders, Prashanthan

    2014-01-01

    Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiology recording encode information on both direction and timing of approaching wavefronts. To test the hypothesis that bipolar electrograms from the pivot of rotors have higher Shannon entropy (ShEn) than electrograms recorded at the periphery due to the spatial dynamics of spiral waves. We studied spiral wave propagation in 2-dimensional sheets constructed using a simple cell automaton (FitzHugh-Nagumo), atrial (Courtemanche-Ramirez-Nattel) and ventricular (Luo-Rudy) myocyte cell models and in a geometric model spiral wave. In each system, bipolar electrogram recordings were simulated, and Shannon entropy maps constructed as a measure of electrogram information content. ShEn was consistently highest in the pivoting region associated with the phase singularity of the spiral wave. This property was consistently preserved across; (i) variation of model system (ii) alterations in bipolar electrode spacing, (iii) alternative bipolar electrode orientation (iv) bipolar electrogram filtering and (v) in the presence of rotor meander. Directional activation plots demonstrated that the origin of high ShEn at the pivot was the directional diversity of wavefront propagation observed in this location. The pivot of the rotor is consistently associated with high Shannon entropy of bipolar electrograms despite differences in action potential model, bipolar electrode spacing, signal filtering and rotor meander. Maximum ShEn is co-located with the pivot for rotors observed in the bipolar electrogram recording mode, and may be an intrinsic property of spiral wave dynamic behaviour.

  8. Recurrence quantification analysis applied to spatiotemporal pattern analysis in high-density mapping of human atrial fibrillation.

    PubMed

    Zeemering, Stef; Bonizzi, Pietro; Maesen, Bart; Peeters, Ralf; Schotten, Ulrich

    2015-01-01

    Spatiotemporal complexity of atrial fibrillation (AF) patterns is often quantified by annotated intracardiac contact mapping. We introduce a new approach that applies recurrence plot (RP) construction followed by recurrence quantification analysis (RQA) to epicardial atrial electrograms, recorded with a high-density grid of electrodes. In 32 patients with no history of AF (aAF, n=11), paroxysmal AF (PAF, n=12) and persistent AF (persAF, n=9), RPs were constructed using a phase space electrogram embedding dimension equal to the estimated AF cycle length. Spatial information was incorporated by 1) averaging the recurrence over all electrodes, and 2) by applying principal component analysis (PCA) to the matrix of embedded electrograms and selecting the first principal component as a representation of spatial diversity. Standard RQA parameters were computed on the constructed RPs and correlated to the number of fibrillation waves per AF cycle (NW). Averaged RP RQA parameters showed no correlation with NW. Correlations improved when applying PCA, with maximum correlation achieved between RP threshold and NW (RR1%, r=0.68, p <; 0.001) and RP determinism (DET, r=-0.64, p <; 0.001). All studied RQA parameters based on the PCA RP were able to discriminate between persAF and aAF/PAF (DET persAF 0.40 ± 0.11 vs. 0.59 ± 0.14/0.62 ± 0.16, p <; 0.01). RP construction and RQA combined with PCA provide a quick and reliable tool to visualize dynamical behaviour and to assess the complexity of contact mapping patterns in AF.

  9. Origin and Characteristics of High Shannon Entropy at the Pivot of Locally Stable Rotors: Insights from Computational Simulation

    PubMed Central

    Gharaviri, Ali; Brooks, Anthony; Chapman, Darius; Lau, Dennis H.; Roberts-Thomson, Kurt C.; Sanders, Prashanthan

    2014-01-01

    Background Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiology recording encode information on both direction and timing of approaching wavefronts. Objective To test the hypothesis that bipolar electrograms from the pivot of rotors have higher Shannon entropy (ShEn) than electrograms recorded at the periphery due to the spatial dynamics of spiral waves. Methods and Results We studied spiral wave propagation in 2-dimensional sheets constructed using a simple cell automaton (FitzHugh-Nagumo), atrial (Courtemanche-Ramirez-Nattel) and ventricular (Luo-Rudy) myocyte cell models and in a geometric model spiral wave. In each system, bipolar electrogram recordings were simulated, and Shannon entropy maps constructed as a measure of electrogram information content. ShEn was consistently highest in the pivoting region associated with the phase singularity of the spiral wave. This property was consistently preserved across; (i) variation of model system (ii) alterations in bipolar electrode spacing, (iii) alternative bipolar electrode orientation (iv) bipolar electrogram filtering and (v) in the presence of rotor meander. Directional activation plots demonstrated that the origin of high ShEn at the pivot was the directional diversity of wavefront propagation observed in this location. Conclusions The pivot of the rotor is consistently associated with high Shannon entropy of bipolar electrograms despite differences in action potential model, bipolar electrode spacing, signal filtering and rotor meander. Maximum ShEn is co-located with the pivot for rotors observed in the bipolar electrogram recording mode, and may be an intrinsic property of spiral wave dynamic behaviour. PMID:25401331

  10. Unraveling the Underlying Arrhythmia Mechanism in Persistent Atrial Fibrillation: Results From the STARLIGHT Study.

    PubMed

    Child, Nicholas; Clayton, Richard H; Roney, Caroline R; Laughner, Jacob I; Shuros, Allan; Neuzil, Petr; Petru, Jan; Jackson, Tom; Porter, Bradley; Bostock, Julian; Niederer, Steven A; Razavi, Reza S; Rinaldi, Christopher A; Taggart, Peter; Wright, Matthew J; Gill, Jaswinder

    2018-06-01

    The mechanisms that initiate and sustain persistent atrial fibrillation are not well characterized. Ablation results remain significantly worse than in paroxysmal atrial fibrillation in which the mechanism is better understood and subsequent targeted therapy has been developed. The aim of this study was to characterize and quantify patterns of activation during atrial fibrillation using contact mapping. Patients with persistent atrial fibrillation (n=14; mean age, 61±8 years; ejection fraction, 59±10%) underwent simultaneous biatrial contact mapping with 64 electrode catheters. The atrial electrograms were transformed into phase, and subsequent spatiotemporal mapping was performed to identify phase singularities (PSs). PSs were located in both atria, but we observed more PSs in the left atrium compared with the right atrium (779±302, 552±235; P =0.015). Although some PSs of duration sufficient to complete >1 rotation were detected, the maximum PS duration was only 1150 ms, and the vast majority (97%) of PSs persisted for too short a period to complete a full rotation. Although in selected patients there was evidence of PS local clustering, overall, PSs were distributed globally throughout both chambers with no clear anatomic predisposition. In a subset of patients (n=7), analysis was repeated using an alternative established atrial PS mapping technique, which confirmed our initial findings. No sustained rotors or localized drivers were detected, and instead, the mechanism of arrhythmia maintenance was consistent with the multiple wavelet hypothesis, with passive activation of short-lived rotational activity. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01765075. © 2018 American Heart Association, Inc.

  11. The effect of activation rate on left atrial bipolar voltage in patients with paroxysmal atrial fibrillation.

    PubMed

    Williams, Steven E; Linton, Nick; O'Neill, Louisa; Harrison, James; Whitaker, John; Mukherjee, Rahul; Rinaldi, Christopher A; Gill, Jaswinder; Niederer, Steven; Wright, Matthew; O'Neill, Mark

    2017-09-01

    Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes. LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4-4-4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak-to-peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or <1 mV (22 ± 15%), and voltage unaffected by coupling interval with plateau voltage >1 mV (17 ± 10%) or <1 mV (13 ± 8%). Electrograms showing bipolar voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P < 0.001). There was a small but significant increase in conduction delay between unipole pairs at sites showing bipolar voltage attenuation (P = 0.026). Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate. © 2017 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.

  12. The effect of activation rate on left atrial bipolar voltage in patients with paroxysmal atrial fibrillation

    PubMed Central

    Linton, Nick; O'Neill, Louisa; Harrison, James; Whitaker, John; Mukherjee, Rahul; Rinaldi, Christopher A.; Gill, Jaswinder; Niederer, Steven; Wright, Matthew; O'Neill, Mark

    2017-01-01

    Abstract Introduction Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes. Methods and results LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4‐4‐4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak‐to‐peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or <1 mV (22 ± 15%), and voltage unaffected by coupling interval with plateau voltage >1 mV (17 ± 10%) or <1 mV (13 ± 8%). Electrograms showing bipolar voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P < 0.001). There was a small but significant increase in conduction delay between unipole pairs at sites showing bipolar voltage attenuation (P = 0.026). Conclusions Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate. PMID:28639747

  13. Biatrial Electrical and Structural Atrial Changes in Heart Failure: Electroanatomic Mapping in Persistent Atrial Fibrillation in Humans.

    PubMed

    Prabhu, Sandeep; Voskoboinik, Aleksandr; McLellan, Alex J A; Peck, Kah Y; Pathik, Bhupesh; Nalliah, Chrishan J; Wong, Geoff R; Azzopardi, Sonia M; Lee, Geoffrey; Mariani, Justin; Ling, Liang-Han; Taylor, Andrew J; Kalman, Jonathan M; Kistler, Peter M

    2018-01-01

    This study sought to characterize the biatrial substrate in heart failure (HF) and persistent atrial fibrillation (PeAF). Atrial fibrillation (AF) and HF frequently coexist; however, the contribution of HF to the biatrial substrate in PeAF is unclear. Consecutive patients with PeAF and normal left ventricular (NLV) systolic function (left ventricular ejection fraction [LVEF] >55%) or idiopathic cardiomyopathy (LVEF ≤45%) undergoing AF ablation were enrolled. In AF, pulmonary vein (PV) cycle length (PVCL) was recorded via a multipolar catheter in each PV and in the left atrial appendage for 100 consecutive cycles. After electrical cardioversion, biatrial electroanatomic mapping was performed. Complex electrograms, voltage, scarring, and conduction velocity were assessed. Forty patients, 20 patients with HF (mean age: 62 ± 8.9 years; AF duration: 15 ± 11 months; LVEF: 33 ± 8.4%) and 20 with NLV (mean age: 59 ± 6.7 years; AF duration: 14 ± 9.1 months; p = 0.69; mean LVEF: 61 ± 3.6%; p < 0.001), were enrolled. HF reduced biatrial tissue voltage (p < 0.001) with greater voltage heterogeneity (p < 0.001). HF was associated with significantly more biatrial fractionation (left atrium [LA]: 30% vs. 9%; p < 0.001; right atrium [RA]: 28% vs. 11%; p < 0.001), low voltage (<0.5 mV) (LA: 23% vs. 6%; p = 0.002; RA: 20% vs 11%; p = 0.006), and scarring (<0.05 mV) in the LA (p = 0.005). HF was associated with a slower average PVCL (185 vs. 164 ms; p = 0.016), which correlated significantly with PV antral bipolar voltage (R = -0.62; p < 0.001) and fractionation (R = 0.46; p = 0.001). HF is associated with significantly reduced biatrial tissue voltage, fractionation, and prolongation of PVCL. Advanced biatrial remodeling may have implications for invasive and noninvasive rhythm control strategies in patients with AF and HF. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Epicardial Breakthrough Waves During Sinus Rhythm: Depiction of the Arrhythmogenic Substrate?

    PubMed

    Mouws, Elisabeth M J P; Lanters, Eva A H; Teuwen, Christophe P; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Bekkers, Jos A; Bogers, Ad J J C; de Groot, Natasja M S

    2017-09-01

    Epicardial breakthrough waves (EBW) during atrial fibrillation are important elements of the arrhythmogenic substrate and result from endo-epicardial asynchrony, which also occurs to some degree during sinus rhythm (SR). We examined the incidence and characteristics of EBW during SR and its possible value in the detection of the arrhythmogenic substrate associated with atrial fibrillation. Intraoperative epicardial mapping (interelectrode distances 2 mm) of the right atrium, Bachmann's bundle, the left atrioventricular groove, and the pulmonary vein area was performed during SR in 381 patients (289 male, 67±10 years) with ischemic or valvular heart disease. EBW were referred to as sinus node breakthrough waves if they were the earliest right atrial activated site. A total of 218 EBW and 57 sinus node breakthrough waves were observed in 168 patients (44%). EBW mostly occurred at right atrium (N=105, 48%) and left atrioventricular groove (N=67, 31%), followed by Bachmann's bundle (N=27, 12%) and pulmonary vein area (N=19, 9%; P <0.001). EBW occurred most often in ischemic heart disease patients (N=114, 49%) compared with (ischemic and) valvular heart disease patients (N=26, 17%; P <0.001). EBW electrograms most often consisted of double and fractionated potentials (N=137, 63%). In case of single potentials, an R wave was observed in 88% (N=71) of EBW, as opposed to 21% of sinus node breakthrough waves (N=5; P <0.001). Fractionated EBW potentials were more often observed at the right atrium and Bachmann's bundle ( P <0.001). During SR, EBW are present in over a third of patients, particularly in thicker parts of the atrial wall. Features of SR EBW indicate that muscular connections between endo- and epicardium underlie EBW and that a slight degree of endo-epicardial asynchrony required for EBW to occur is already present in some areas during SR. Hence, an anatomic substrate is present, which may enhance the occurrence of EBW during atrial fibrillation, thereby promoting atrial fibrillation persistence. © 2017 American Heart Association, Inc.

  15. Cigarette smoking causes a worse long-term outcome in persistent atrial fibrillation following catheter ablation.

    PubMed

    Cheng, Wen-Han; Lo, Li-Wei; Lin, Yenn-Jiang; Chang, Shih-Lin; Hu, Yu-Feng; Hung, Yuan; Chung, Fa-Po; Chang, Ting-Yung; Huang, Ting-Chung; Yamada, Shinya; Salim, Simon; Te, Abigail Louise D; Liao, Jo-Nan; Tuan, Ta-Chuan; Chao, Tze-Fan; Tsai, Tseng-Ying; Liu, Shin-Huei; Chen, Shih-Ann

    2018-02-09

    Cigarette smoking contributes to the development of atrial fibrosis via nicotine. The impact of smoking on ablation results in persistent atrial fibrillation (AF) is unknown. We aimed to investigate the triggers and long-term outcome between smokers and nonsmokers in the patients with persistent AF after catheter ablation. This study included 201 (177 males, 53 ± 10 years old) patients who received index catheter ablation, including pulmonary vein isolation (PVI) and complex fractionated atrial electrograms (CFAEs) ablation for persistent AF, retrospectively. Electrophysiological characteristics at the index procedure and long-term outcome were investigated to determine the differences between smokers and nonsmokers. Baseline characteristics were similar between two groups. Pulmonary vein (PV) triggers were found in all patients in the two groups. There was a higher incidence of nonpulmonary vein (NPV) triggers in smokers than in nonsmokers (61% vs. 31%, P < 0.05). There were no differences of the long-term ablation outcomes between smokers and nonsmokers in Kaplan-Meier analysis. Smokers with PV plus right atrial NPV (RA-NPV) triggers had a higher incidence of recurrence (log-rank P < 0.05) than those without RA-NPV triggers, but not in nonsmokers, after a mean follow-up of 31 ± 25 months. Smoking increases the incidence of NPV triggers in patients with persistent AF. Smokers who have RA-NPV triggers during index procedure do have a worse outcome after catheter ablation, indicating the harmful effects of nicotine to right atrium. © 2018 Wiley Periodicals, Inc.

  16. Initial Experience With Ultra High-Density Mapping of Human Right Atria.

    PubMed

    Bollmann, Andreas; Hilbert, Sebastian; John, Silke; Kosiuk, Jedrzej; Hindricks, Gerhard

    2016-02-01

    Recently, an automatic, high-resolution mapping system has been presented to accurately and quickly identify right atrial geometry and activation patterns in animals, but human data are lacking. This study aims to assess the clinical feasibility and accuracy of high-density electroanatomical mapping of various RA arrhythmias. Electroanatomical maps of the RA (35 partial and 24 complete) were created in 23 patients using a novel mini-basket catheter with 64 electrodes and automatic electrogram annotation. Median acquisition time was 6:43 minutes (0:39-23:05 minutes) with shorter times for partial (4.03 ± 4.13 minutes) than for complete maps (9.41 ± 4.92 minutes). During mapping 3,236 (710-16,306) data points were automatically annotated without manual correction. Maps obtained during sinus rhythm created geometry consistent with CT imaging and demonstrated activation originating at the middle to superior crista terminalis, while maps during CS pacing showed right atrial activation beginning at the infero-septal region. Activation patterns were consistent with cavotricuspid isthmus-dependent atrial flutter (n = 4), complex reentry tachycardia (n = 1), or ectopic atrial tachycardia (n = 2). His bundle and fractionated potentials in the slow pathway region were automatically detected in all patients. Ablation of the cavotricuspid isthmus (n = 9), the atrio-ventricular node (n = 2), atrial ectopy (n = 2), and the slow pathway (n = 3) was successfully and safely performed. RA mapping with this automatic high-density mapping system is fast, feasible, and safe. It is possible to reproducibly identify propagation of atrial activation during sinus rhythm, various tachycardias, and also complex reentrant arrhythmias. © 2015 Wiley Periodicals, Inc.

  17. A diagnostic algorithm to optimize data collection and interpretation of Ripple Maps in atrial tachycardias.

    PubMed

    Koa-Wing, Michael; Nakagawa, Hiroshi; Luther, Vishal; Jamil-Copley, Shahnaz; Linton, Nick; Sandler, Belinda; Qureshi, Norman; Peters, Nicholas S; Davies, D Wyn; Francis, Darrel P; Jackman, Warren; Kanagaratnam, Prapa

    2015-11-15

    Ripple Mapping (RM) is designed to overcome the limitations of existing isochronal 3D mapping systems by representing the intracardiac electrogram as a dynamic bar on a surface bipolar voltage map that changes in height according to the electrogram voltage-time relationship, relative to a fiduciary point. We tested the hypothesis that standard approaches to atrial tachycardia CARTO™ activation maps were inadequate for RM creation and interpretation. From the results, we aimed to develop an algorithm to optimize RMs for future prospective testing on a clinical RM platform. CARTO-XP™ activation maps from atrial tachycardia ablations were reviewed by two blinded assessors on an off-line RM workstation. Ripple Maps were graded according to a diagnostic confidence scale (Grade I - high confidence with clear pattern of activation through to Grade IV - non-diagnostic). The RM-based diagnoses were corroborated against the clinical diagnoses. 43 RMs from 14 patients were classified as Grade I (5 [11.5%]); Grade II (17 [39.5%]); Grade III (9 [21%]) and Grade IV (12 [28%]). Causes of low gradings/errors included the following: insufficient chamber point density; window-of-interest<100% of cycle length (CL); <95% tachycardia CL mapped; variability of CL and/or unstable fiducial reference marker; and suboptimal bar height and scar settings. A data collection and map interpretation algorithm has been developed to optimize Ripple Maps in atrial tachycardias. This algorithm requires prospective testing on a real-time clinical platform. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Correlative anatomy for the electrophysiologist: ablation for atrial fibrillation. Part II: regional anatomy of the atria and relevance to damage of adjacent structures during AF ablation.

    PubMed

    Macedo, Paula G; Kapa, Suraj; Mears, Jennifer A; Fratianni, Amy; Asirvatham, Samuel J

    2010-07-01

    Ablation procedures for atrial fibrillation have become an established and increasingly used option for managing patients with symptomatic arrhythmia. The anatomic structures relevant to the pathogenesis of atrial fibrillation and ablation procedures are varied and include the pulmonary veins, other thoracic veins, the left atrial myocardium, and autonomic ganglia. Exact regional anatomic knowledge of these structures is essential to allow correlation with fluoroscopy and electrograms and, importantly, to avoid complications from damage of adjacent structures within the chest. We present this information as a series of 2 articles. In a prior issue, we have discussed the thoracic vein anatomy relevant to paroxysmal atrial fibrillation. In the present article, we focus on the atria themselves, the autonomic ganglia, and anatomic issues relevant for minimizing complications during atrial fibrillation ablation.

  19. A preliminary study on atrial epicardial mapping signals based on Graph Theory.

    PubMed

    Sun, Liqian; Yang, Cuiwei; Zhang, Lin; Chen, Ying; Wu, Zhong; Shao, Jun

    2014-07-01

    In order to get a better understanding of atrial fibrillation, we introduced a method based on Graph Theory to interpret the relations of different parts of the atria. Atrial electrograms under sinus rhythm and atrial fibrillation were collected from eight living mongrel dogs with cholinergic AF model. These epicardial signals were acquired from 95 unipolar electrodes attached to the surface of the atria and four pulmonary veins. Then, we analyzed the electrode correlations using Graph Theory. The topology, the connectivity and the parameters of graphs during different rhythms were studied. Our results showed that the connectivity of graphs varied from sinus rhythm to atrial fibrillation and there were parameter gradients in various parts of the atria. The results provide spatial insight into the interaction between different parts of the atria and the method may have its potential for studying atrial fibrillation. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Spatial Relation Between Left Atrial Anatomical Contact Areas and Circular Activation in Persistent Atrial Fibrillation.

    PubMed

    Nakahara, Shiro; Yamaguchi, Takanori; Hori, Yuichi; Anjo, Naofumi; Hayashi, Akiko; Kobayashi, Sayuki; Komatsu, Takaaki; Sakai, Yoshihiko; Fukui, Akira; Tsuchiya, Takeshi; Taguchi, Isao

    2016-05-01

    Atrial low-voltage zones (LVZs) may be related to maintenance of atrial fibrillation (AF). The influence of left atrial (LA) contact areas (CoAs) on reentrant or rotor-like sources maintaining AF has not been investigated. Forty patients with persistent AF (PsAF) were analyzed. Three representative CoA regions in the LA (ascending aorta: anterior wall; descending aorta: left inferior pulmonary vein; and vertebrae: posterior wall) were visualized by enhanced CT. Using circular catheters, the LVZs (<0.5 mV) were assessed after restoration of SR, and local activation mapping and frequency domain analyses were performed after induction of AF. Circular activation during AF was visually defined as sites with ≥2 rotations by serial electrograms encompassing >80% of the mean AF cycle length. A pivot was defined as the core of the localized circular activation. Anterior (39/40 patients, 98%), left pulmonary vein antrum (27/40, 68%), and posterior (19/40, 48%) CoAs were identified, and 80% (68/85) of those sites were overlapped by or close (<3 mm) to LVZs. Thirty-six (90%) patients demonstrated circular activation (3.1±1.7 sites/patients) along with significantly higher organized dominant frequencies (6.3 ± 0.5 Hz, regularity-index: 0.26 [0.23-0.41]) within the LA, and the average electrogram amplitude of those pivots was 0.30 mV (0.18-0.52). Of those sites, 55% (66/120) were located at or close to CoA regions. Catheter ablation including of LVZs neighboring CoAs terminated AF in 9 (23%) patients. External anatomical structures contacting the LA may be related to unique conduction properties in diseased myocardium necessary for PsAF maintenance. © 2016 Wiley Periodicals, Inc.

  1. Intermittent atrial tachycardia promotes repolarization alternans and conduction slowing during rapid rates, and increases susceptibility to atrial fibrillation in a free-behaving sheep model.

    PubMed

    Monigatti-Tenkorang, Joanna; Jousset, Florian; Pascale, Patrizio; Vesin, Jean-Marc; Ruchat, Patrick; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne

    2014-04-01

    Paroxysmal atrial fibrillation (AF) may be triggered by intermittent atrial tachycardia, and ultimately lead to persistent AF. However, the mechanisms by which intermittent atrial tachycardia promotes sustained AF are not well understood. Eight sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms, and for the delivery of electrophysiological stimulation protocols and intermittent right atrial tachycardia. Right atrial kinetics of activation recovery interval (ARI) as a surrogate for action potential duration, of conduction time and velocity, and of repolarization alternans were analyzed at incremental pacing rates during the remodeling process induced by weeks of intermittent atrial tachycardia until the development of sustained AF. Intermittent atrial tachycardia decreased ARI and blunted its rate adaptation, facilitated atrial capture, and slowed conduction at high rates, and increased susceptibility to pacing-induced AF. In spite of blunted ARI rate adaptation, right atrial repolarization alternans was maintained during remodeling, and further increased in magnitude just before rapid pacing-induced AF. This study suggests that weeks of intermittent right atrial tachycardia result in a gradual electrical remodeling favorable for wavebreaks and reentry that may facilitate fibrillation. © 2014 Wiley Periodicals, Inc.

  2. Investigation of atrial vulnerability by analysis of the sinus node EG from atrial fibrillation models using a phase synchronization method.

    PubMed

    Chen, Ying; Wu, Zhong; Yang, Cuiwei; Shao, Jun; Wong, Kelvin Kian Loong; Abbott, Derek

    2012-09-01

    Atrial fibrillation (AF) can result in life-threatening arrhythmia, and a clinically convenient means for detecting vulnerability remains elusive. We investigated atrial vulnerability by analyzing the sinus electrogram (EG) from AF animal models using a phase synchronization method. Using acetylcholine (ACh)-induced acute canine AF models (n= 4), a total of 128 electrical leads were attached to the surface of the anterior and posterior atria, and the pulmonary veins to form an electrocardiological mapping system. ACh was injected at varying concentrations with ladder-type adjustments. Sinus EGs and induced AF EGs that pertain to specific ACh concentrations were recorded.We hypothesize that the atrial vulnerability may be correlated with the Shannon entropy (SE) of the phase difference matrix that is extracted from the sinus EG. Our research suggests that the combination of SE with the synchronization method enables the sinus node EG to be analyzed and used to estimate atrial vulnerability.

  3. The identification of conduction gaps after pulmonary vein isolation using a new electroanatomic mapping system.

    PubMed

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2017-11-01

    The reconnection of left atrial-pulmonary vein (LA-PV) conduction after the initial procedure of pulmonary vein (PV) isolation is not rare, and is one of the main cause of atrial fibrillation (AF) recurrence after PV isolation. We investigated feasibility of a new ultrahigh-resolution mapping system using a 64-pole small basket catheter for the identification of LA-PV conduction gaps. This prospective study included 31 consecutive patients (20 with persistent AF) undergoing a second ablation after a PV isolation procedure with LA-PV reconnected conduction at any of the 4 PVs. An LA-PV map was created using the mapping system, and ablation was performed at the estimated gap location. The propagation map identified 54 gaps from 39 ipsilateral PV pairs, requiring manual electrogram reannotation for 23 gaps (43%). Gaps at the anterior and carinal regions of left and right ipsilateral PVs required manual electrogram reannotation more frequently than the other regions. The voltage map could identify the gap only in 19 instances (35%). Electrophysiological properties of the gaps (multiple gaps in the same ipsilateral PVs, conduction time, velocity, width, and length) did not differ between those needing and not needing manual electrogram reannotation. During the gap ablation, either the activation sequence alteration or elimination of PV potentials was observed using a circular catheter placed in the PV, suggesting that all the identified gaps were correct. This new electroanatomic mapping system visualized all the LA-PV gaps in patients undergoing a second AF ablation. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  4. Characteristics of atrial fibrillation cycle length predict restoration of sinus rhythm by catheter ablation.

    PubMed

    Di Marco, Luigi Yuri; Raine, Daniel; Bourke, John P; Langley, Philip

    2013-09-01

    Successful termination of atrial fibrillation (AF) during catheter ablation (CA) is associated with arrhythmia-free follow-up. Preablation factors such as mean atrial fibrillation cycle length (AFCL) predict the likelihood of AF termination during ablation but recurring patterns and AFCL stability have not been evaluated. To investigate novel predictors of acute and postoperative ablation outcomes from intracardiac electrograms: (1) recurring AFCL patterns and (2) localization index (LI) of the instantaneous fibrillatory rate distribution. Sixty-two patients with AF (32 paroxysmal AF; 45 men; age 57 ± 10 years) referred for CA were enrolled. One-minute electrogram was recorded from coronary sinus (CS; 5 bipoles) and right atrial appendage (HRA; 2 bipoles). Atrial activations were detected automatically to derive the AFCL and instantaneous fibrillatory rate (inverse of AFCL) time series. Recurring AFCL patterns were quantified by using recurrence plot indices (RPIs): percentage determinism, entropy of determinism, and maximum diagonal length. AFCL stability was determined by using the LI. The CA outcome predictivity of individual indices was assessed. Patients with terminated atrial fibrillation (T-AF) had higher RPI (P < .05 in CS7-8) and LI than did those with nonterminated atrial fibrillation (P < .005 in CS3-4; P < .05 in CS5-6, CS7-8, and HRA). Patients free of arrhythmia after 3-month follow-up had higher RPI and LI (all P < .05 in CS7-8). All indices except percentage determinism predicted T-AF in CS7-8 (area under the curve [AUC] ≥ 0.71; odds ratio [OR] ≥ 4.50; P < .05). The median AFCL and LI predicted T-AF in HRAD (AUC ≥ 0.75; OR ≥ 7.76; P < .05). The RPI and LI predicted 3-month follow-up in CS7-8 (AUC ≥ 0.68; OR ≥ 4.17; P < .05). AFCL recurrence and stability indices could be used in selecting patients more likely to benefit from CA. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Long-term biatrial recordings in post-operative atrial fibrillation.

    PubMed

    Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F

    2010-01-01

    Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.

  6. Three-dimensional dominant frequency mapping using autoregressive spectral analysis of atrial electrograms of patients in persistent atrial fibrillation.

    PubMed

    Salinet, João L; Masca, Nicholas; Stafford, Peter J; Ng, G André; Schlindwein, Fernando S

    2016-03-08

    Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based approach to generate the three-dimensional dominant frequency (3D DF) maps during electrophysiology (EP) procedures but literature is restricted on using alternative spectral estimation techniques that can have a better frequency resolution that FFT-based spectral estimation. Autoregressive (AR) model-based spectral estimation techniques, with emphasis on selection of appropriate sampling rate and AR model order, were implemented to generate high-density 3D DF maps of atrial electrograms (AEGs) in persistent atrial fibrillation (persAF). For each patient, 2048 simultaneous AEGs were recorded for 20.478 s-long segments in the left atrium (LA) and exported for analysis, together with their anatomical locations. After the DFs were identified using AR-based spectral estimation, they were colour coded to produce sequential 3D DF maps. These maps were systematically compared with maps found using the Fourier-based approach. 3D DF maps can be obtained using AR-based spectral estimation after AEGs downsampling (DS) and the resulting maps are very similar to those obtained using FFT-based spectral estimation (mean 90.23 %). There were no significant differences between AR techniques (p = 0.62). The processing time for AR-based approach was considerably shorter (from 5.44 to 5.05 s) when lower sampling frequencies and model order values were used. Higher levels of DS presented higher rates of DF agreement (sampling frequency of 37.5 Hz). We have demonstrated the feasibility of using AR spectral estimation methods for producing 3D DF maps and characterised their differences to the maps produced using the FFT technique, offering an alternative approach for 3D DF computation in human persAF studies.

  7. Outcomes after cryoballoon or radiofrequency ablation for persistent atrial fibrillation: a multicentric propensity-score matched study.

    PubMed

    Boveda, Serge; Providência, Rui; Defaye, Pascal; Pavin, Dominique; Cebron, Jean-Pierre; Anselme, Frederic; Halimi, Franck; Khoueiry, Ziad; Combes, Nicolas; Combes, Stephane; Jacob, Sophie; Albenque, Jean-Paul; Sousa, Pedro

    2016-11-01

    Recent data show no benefit of additional ablation beyond pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF). Evidence suggests that radiofrequency energy (RF) and cryoballoon (CRYO) have comparable efficacy for PVI. We aimed to assess the outcomes after a single catheter ablation procedure, comparing PVI using CRYO vs. RF ablation for PVI plus additional ablation in a cohort of patients with persistent AF. In this prospective multicenter propensity score-matched comparison, 59 consecutive patients undergoing CRYO ablation of persistent AF were matched to 59 patients treated with RF from November 2010 to June 2012. During a mean follow-up of 15.6 ± 11.5 months, 43.2 % of patients presented atrial arrhythmia relapse after a blanking period of 3 months, which was comparable between the two groups (40.7 % in CRYO vs. 45.8 % in RF, Log rank P = 0.14; HR = 0.67, 95 %CI 0.38-1.16, P = 0.15), despite the fact that 52.5 % of RF patients add additional complex fractionated atrial electrogram ablation, as well as left atrial linear ablation in over two-thirds (roof line in 67.8 % and mitral isthmus in 32.2 %). On multivariate Cox regression, only AF duration in years (HR = 1.10, 95 %CI 1.01-1.10, P = 0.04) was a predictor of relapse. Patients undergoing RF ablation presented a numerically, but non-significantly, lower complication rate (6.8 vs 10.2 %, P = 0.51). In our multicenter experience, freedom from atrial arrhythmias was comparable among matched patients treated with CRYO and RF, despite non-significant trends in favor of RF in terms of complications, at the cost of longer procedure times.

  8. Angiotensin converting enzyme 2 activity and human atrial fibrillation: increased plasma angiotensin converting enzyme 2 activity is associated with atrial fibrillation and more advanced left atrial structural remodelling.

    PubMed

    Walters, Tomos E; Kalman, Jonathan M; Patel, Sheila K; Mearns, Megan; Velkoska, Elena; Burrell, Louise M

    2017-08-01

    Angiotensin converting enzyme 2 (ACE2) is an integral membrane protein whose main action is to degrade angiotensin II. Plasma ACE2 activity is increased in various cardiovascular diseases. We aimed to determine the relationship between plasma ACE2 activity and human atrial fibrillation (AF), and in particular its relationship to left atrial (LA) structural remodelling. One hundred and three participants from a tertiary arrhythmia centre, including 58 with paroxysmal AF (PAF), 20 with persistent AF (PersAF), and 25 controls, underwent clinical evaluation, echocardiographic analysis, and measurement of plasma ACE2 activity. A subgroup of 20 participants underwent invasive LA electroanatomic mapping. Plasma ACE2 activity levels were increased in AF [control 13.3 (9.5-22.3) pmol/min/mL; PAF 16.9 (9.7-27.3) pmol/min/mL; PersAF 22.8 (13.7-33.4) pmol/min/mL, P = 0.006]. Elevated plasma ACE2 was associated with older age, male gender, hypertension and vascular disease, elevated left ventricular (LV) mass, impaired LV diastolic function and advanced atrial disease (P < 0.05 for all). Independent predictors of elevated plasma ACE2 activity were AF (P = 0.04) and vascular disease (P < 0.01). There was a significant relationship between elevated ACE2 activity and low mean LA bipolar voltage (adjusted R2 = 0.22, P = 0.03), a high proportion of complex fractionated electrograms (R2 = 0.32, P = 0.009) and a long LA activation time (R2 = 0.20, P = 0.04). Plasma ACE2 activity is elevated in human AF. Both AF and vascular disease predict elevated plasma ACE2 activity, and elevated plasma ACE2 is significantly associated with more advanced LA structural remodelling. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  9. Recurrent patterns of atrial depolarization during atrial fibrillation assessed by recurrence plot quantification.

    PubMed

    Censi, F; Barbaro, V; Bartolini, P; Calcagnini, G; Michelucci, A; Gensini, G F; Cerutti, S

    2000-01-01

    The aim of this study was to determine the presence of organization of atrial activation processes during atrial fibrillation (AF) by assessing whether the activation sequences are wholly random or are governed by deterministic mechanisms. We performed both linear and nonlinear analyses based on the cross correlation function (CCF) and recurrence plot quantification (RPQ), respectively. Recurrence plots were quantified by three variables: percent recurrence (PR), percent determinism (PD), and entropy of recurrences (ER). We recorded bipolar intra-atrial electrograms in two atrial sites during chronic AF in 19 informed subjects, following two protocols. In one, both recording sites were in the right atrium; in the other protocol, one site was in the right atrium, the other one in the left atrium. We extracted 19 episodes of type I AF (Wells' classification). RPQ detected transient recurrent patterns in all the episodes, while CCF was significant only in ten episodes. Surrogate data analysis, based on a cross-phase randomization procedure, decreased PR, PD, and ER values. The detection of spatiotemporal recurrent patterns together with the surrogate data results indicate that during AF a certain degree of local organization exists, likely caused by deterministic mechanisms of activation.

  10. Origin and pharmacological response of atrial tachyarrhythmias induced by activation of mediastinal nerves in canines.

    PubMed

    Armour, J Andrew; Richer, Louis-Philippe; Pagé, Pierre; Vinet, Alain; Kus, Teresa; Vermeulen, Michel; Nadeau, Réginald; Cardinal, René

    2005-03-31

    We sought to determine the sites of origin of atrial tachyarrhythmias induced by activating mediastinal nerves, as well as the response of such arrhythmias to autonomic modulation. Under general anaesthesia, atrioventricular block was induced after thoracotomy in 19 canines. Brief trains of 5 electrical stimuli were delivered to right-sided mediastinal nerves during the atrial refractory period. Unipolar electrograms were recorded from 191 right and left atrial epicardial sites under several conditions, i.e. (i) with intact nervous systems and following (ii) acute decentralization of the intrathoracic nervous system or administration of (iii) atropine, (iv) timolol, (v) hexamethonium. Concomitant right atrial endocardial mapping was performed in 7 of these dogs. Mediastinal nerve stimulation consistently initiated bradycardia followed by atrial tachyarrhythmias. In the initial tachyarrhythmia beats, early epicardial breakthroughs were identified in the right atrial free wall (28/50 episodes) or Bachmann bundle region (22/50), which corresponded to endocardial sites of origin associated with the right atrial subsidiary pacemaker complex, i.e. the crista terminalis and dorsal locations including the right atrial aspect of the interatrial septum. Neuronally induced responses were eliminated by atropine, modified by timolol and unaffected by acute neuronal decentralization. After hexamethonium, responses to extra-pericardial but not intra-pericardial nerve stimulation were eliminated. It is concluded that concomitant activation of cholinergic and adrenergic efferent intrinsic cardiac neurons induced by right-sided efferent neuronal stimulation initiates atrial tachyarrhythmias that originate from foci anatomically related to the right atrial pacemaker complex and tissues underlying major atrial ganglionated plexuses.

  11. Spatially divergent cardiac responses to nicotinic stimulation of ganglionated plexus neurons in the canine heart.

    PubMed

    Cardinal, René; Pagé, Pierre; Vermeulen, Michel; Ardell, Jeffrey L; Armour, J Andrew

    2009-01-28

    Ganglionated plexuses (GPs) are major constituents of the intrinsic cardiac nervous system, the final common integrator of regional cardiac control. We hypothesized that nicotinic stimulation of individual GPs exerts divergent regional influences, affecting atrial as well as ventricular functions. In 22 anesthetized canines, unipolar electrograms were recorded from 127 atrial and 127 ventricular epicardial loci during nicotine injection (100 mcg in 0.1 ml) into either the 1) right atrial (RA), 2) dorsal atrial, 3) left atrial, 4) inferior vena cava-inferior left atrial, 5) right ventricular, 6) ventral septal ventricular or 7) cranial medial ventricular (CMV) GP. In addition to sinus and AV nodal function, neural effects on atrial and ventricular repolarization were identified as changes in the area subtended by unipolar recordings under basal conditions and at maximum neurally-induced effects. Animals were studied with intact AV node or following ablation to achieve ventricular rate control. Atrial rate was affected in response to stimulation of all 7 GPs with an incidence of 50-95% of the animals among the different GPs. AV conduction was affected following stimulation of 6/7 GP with an incidence of 22-75% among GPs. Atrial and ventricular repolarization properties were affected by atrial as well as ventricular GP stimulation. Distinct regional patterns of repolarization changes were identified in response to stimulation of individual GPs. RAGP predominantly affected the RA and posterior right ventricular walls whereas CMVGP elicited biatrial and biventricular repolarization changes. Spatially divergent and overlapping cardiac regions are affected in response to nicotinic stimulation of neurons in individual GPs.

  12. Electrophysiological Rotor Ablation in In-Silico Modeling of Atrial Fibrillation: Comparisons with Dominant Frequency, Shannon Entropy, and Phase Singularity.

    PubMed

    Hwang, Minki; Song, Jun-Seop; Lee, Young-Seon; Li, Changyong; Shim, Eun Bo; Pak, Hui-Nam

    2016-01-01

    Although rotors have been considered among the drivers of atrial fibrillation (AF), the rotor definition is inconsistent. We evaluated the nature of rotors in 2D and 3D in- silico models of persistent AF (PeAF) by analyzing phase singularity (PS), dominant frequency (DF), Shannon entropy (ShEn), and complex fractionated atrial electrogram cycle length (CFAE-CL) and their ablation. Mother rotor was spatiotemporally defined as stationary reentries with a meandering tip remaining within half the wavelength and lasting longer than 5 s. We generated 2D- and 3D-maps of the PS, DF, ShEn, and CFAE-CL during AF. The spatial correlations and ablation outcomes targeting each parameter were analyzed. 1. In the 2D PeAF model, we observed a mother rotor that matched relatively well with DF (>9 Hz, 71.0%, p<0.001), ShEn (upper 2.5%, 33.2%, p<0.001), and CFAE-CL (lower 2.5%, 23.7%, p<0.001). 2. The 3D-PeAF model also showed mother rotors that had spatial correlations with DF (>5.5 Hz, 39.7%, p<0.001), ShEn (upper 8.5%, 15.1%, p <0.001), and CFAE (lower 8.5%, 8.0%, p = 0.002). 3. In both the 2D and 3D models, virtual ablation targeting the upper 5% of the DF terminated AF within 20 s, but not the ablations based on long-lasting PS, high ShEn area, or lower CFAE-CL area. Mother rotors were observed in both 2D and 3D human AF models. Rotor locations were well represented by DF, and their virtual ablation altered wave dynamics and terminated AF.

  13. Electrophysiological Rotor Ablation in In-Silico Modeling of Atrial Fibrillation: Comparisons with Dominant Frequency, Shannon Entropy, and Phase Singularity

    PubMed Central

    Hwang, Minki; Song, Jun-Seop; Lee, Young-Seon; Li, Changyong; Shim, Eun Bo; Pak, Hui-Nam

    2016-01-01

    Background Although rotors have been considered among the drivers of atrial fibrillation (AF), the rotor definition is inconsistent. We evaluated the nature of rotors in 2D and 3D in- silico models of persistent AF (PeAF) by analyzing phase singularity (PS), dominant frequency (DF), Shannon entropy (ShEn), and complex fractionated atrial electrogram cycle length (CFAE-CL) and their ablation. Methods Mother rotor was spatiotemporally defined as stationary reentries with a meandering tip remaining within half the wavelength and lasting longer than 5 s. We generated 2D- and 3D-maps of the PS, DF, ShEn, and CFAE-CL during AF. The spatial correlations and ablation outcomes targeting each parameter were analyzed. Results 1. In the 2D PeAF model, we observed a mother rotor that matched relatively well with DF (>9 Hz, 71.0%, p<0.001), ShEn (upper 2.5%, 33.2%, p<0.001), and CFAE-CL (lower 2.5%, 23.7%, p<0.001). 2. The 3D-PeAF model also showed mother rotors that had spatial correlations with DF (>5.5 Hz, 39.7%, p<0.001), ShEn (upper 8.5%, 15.1%, p <0.001), and CFAE (lower 8.5%, 8.0%, p = 0.002). 3. In both the 2D and 3D models, virtual ablation targeting the upper 5% of the DF terminated AF within 20 s, but not the ablations based on long-lasting PS, high ShEn area, or lower CFAE-CL area. Conclusion Mother rotors were observed in both 2D and 3D human AF models. Rotor locations were well represented by DF, and their virtual ablation altered wave dynamics and terminated AF. PMID:26909492

  14. Evaluation of a novel high-resolution mapping technology for ablation of recurrent scar-related atrial tachycardias.

    PubMed

    Anter, Elad; McElderry, Thomas H; Contreras-Valdes, Fernando M; Li, Jianqing; Tung, Patricia; Leshem, Eran; Haffajee, Charles I; Nakagawa, Hiroshi; Josephson, Mark E

    2016-10-01

    Rhythmia is a new technology capable of rapid and high-resolution mapping. However, its potential advantage over existing technologies in mapping complex scar-related atrial tachycardias (ATs) has not yet been evaluated. The purpose of this study was to examine the utility of Rhythmia for mapping scar-related ATs in patients who had failed previous ablation procedure(s). This multicenter study included 20 patients with recurrent ATs within 2 years after a previous ablation procedure (1.8 ± 0.7 per patient). In all cases, the ATs could not be adequately mapped during the index procedure because of scar with fractionated electrograms, precluding accurate time annotation, frequent change in the tachycardia in response to pacing, and/or degeneration into atrial fibrillation. These patients underwent repeat mapping and ablation procedure with Rhythmia. From a total of 28 inducible ATs, 24 were successfully mapped. Eighteen ATs (75%) terminated during radiofrequency ablation and 4 (16.6%) with catheter pressure or entrainment from the site of origin or isthmus. Two ATs that were mapped to the interatrial septum slowed but did not terminate with ablation. In 21 of 24 ATs the mechanism was macroreentry, while in 3 of 24 the mechanism was focal. Interestingly, in 5 patients with previously failed ablation of an allegedly "focal" tachycardia, high-resolution mapping demonstrated macroreentrant arrhythmia. The mean mapping time was 28.6 ± 17 minutes, and the mean radiofrequency ablation time to arrhythmia termination was 3.2 ± 2.6 minutes. During a mean follow-up of 7.5 ± 3.1 months, 15 of 20 patients (75%) were free of AT recurrences. The Rhythmia mapping system may be advantageous for mapping complex scar-related ATs. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Epicardial-endocardial breakthrough during stable atrial macroreentry: Evidence from ultra-high-resolution 3-dimensional mapping.

    PubMed

    Pathik, Bhupesh; Lee, Geoffrey; Sacher, Frédéric; Haïssaguerre, Michel; Jaïs, Pierre; Massoullié, Grégoire; Derval, Nicolas; Sanders, Prashanthan; Kistler, Peter; Kalman, Jonathan M

    2017-08-01

    Evidence for epicardial-endocardial breakthrough (EEB) is derived from mapping inferences in patients with atrial fibrillation who may also have focal activations. The purpose of this study was to investigate whether EEB could be discerned during stable right atrial (RA) macroreentry using high-density high-spatial resolution 3-dimensional mapping. Macroreentry was diagnosed using 3-dimensional mapping and entrainment. Bipolar maps were reviewed for EEB defined as (1) presence of focal endocardial activation with radial spread unaccounted for by an endocardial wavefront and (2) present with the same timing on every tachycardia cycle. The EEB site was always in proximity to a line of endocardial conduction slowing or block. Distance and conduction velocity from the line of block to the EEB site was calculated. Electrograms at EEB sites were individually analyzed for morphology and to confirm direction of activation. Entrainment was performed at EEB sites. Twenty-six patients were studied. Fourteen examples of EEB were seen: 11 at the posterior RA (4 at the superior portion of the posterior wall and 7 at the inferior section) and 1 each at the cavotricuspid isthmus postablation, RA septum, and inferolateral RA. The mean area of the EEB site was 0.6 ± 0.2 cm 2 . A mean of 79.5% ± 18.6% of unipolar electrograms at the EEB site demonstrated an rS morphology. The mean distance and conduction velocity from the line of endocardial block to the EEB site at the posterior RA was 13.6 ± 2.3 mm and 59.3 ± 12.3 cm/s, respectively. In 4 patients, entrainment demonstrated that EEB sites were within the circuit and in 1 of these patients critical to arrhythmia maintenance. Activation maps during tachycardia and coronary sinus pacing demonstrated EEB at the same anatomic site. EEB sites were demonstrated in stable atrial macroreentry supported by systematic entrainment confirmation and demonstration of the same phenomenon during pacing. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Kinetics of atrial repolarization alternans in a free-behaving ovine model.

    PubMed

    Jousset, Florian; Tenkorang, Joanna; Vesin, Jean-Marc; Pascale, Patrizio; Ruchat, Patrick; Rollin, Anne Garderes; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne

    2012-09-01

    Kinetics of Atrial Repolarization Alternans. Repolarization alternans (Re-ALT), a beat-to-beat alternation in action potential repolarization, promotes dispersion of repolarization, wavebreaks, and reentry. Recently, Re-ALT has been shown to play an important role in the transition from rapid pacing to atrial fibrillation (AF) in humans. The detailed kinetics of atrial Re-ALT, however, has not been reported so far. We developed a chronic free-behaving ovine pacing model to study the kinetics of atrial Re-ALT as a function of pacing rate. Thirteen sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms and delivery of rapid pacing protocols. Beat-to-beat differences in the atrial T-wave apex amplitude as a measure of Re-ALT and activation time were analyzed at incremental pacing rates until the effective refractory period (ERP) defined as stable 2:1 capture. Atrial Re-ALT appeared intermittently but without periodicity, and increased in amplitude as a function of pacing rate until ERP. Intermittent 2:1 atrial capture was observed at pacing cycle lengths 40 ms above ERP, and increased in duration as a function of pacing rate. Episodes of rapid pacing-induced AF were rare, and were preceded by Re-ALT or complex oscillations of atrial repolarization, but without intermittent capture. We show in vivo that atrial Re-ALT developed and increased in magnitude with rate until stable 2:1 capture. In rare instances where capture failure did not occur, Re-ALT and complex oscillations of repolarization surged and preceded AF initiation. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1003-1012, September 2012). © 2012 Wiley Periodicals, Inc.

  17. Electrophysiologic studies in atrial fibrillation. Slow conduction of premature impulses: a possible manifestation of the background for reentry.

    PubMed

    Cosio, F G; Palacios, J; Vidal, J M; Cocina, E G; Gómez-Sánchez, M A; Tamargo, L

    1983-01-01

    Extrastimulus-induced intraatrial conduction delays were measured in 12 patients with documented episodes of atrial fibrillation (AF) by recording atrial electrograms at the high right atrium, His bundle region, and coronary sinus. Seventeen patients with and without heart disease, but without atrial arrhythmias served as the control group. During baseline-paced atrial rhythms, a conduction delay zone could be delineated, near the atrial effective refractory period, during which all extrastimuli produced conduction delays. When compared at the same paced cycle lengths (500 to 650 ms), the patients with AF had shorter atrial effective refractory periods (mean +/- standard deviation 206 +/- 24.1 versus 233 +/- 28.2 in control patients, p less than 0.02), wider conduction delay zones (79 +/- 21.7 ms versus 52 +/- 21 in control patients, p less than 0.01), and longer conduction delays both to the His bundle region (64 +/- 18.3 ms versus 35 +/- 21.7 in control patients, p less than 0.005) and the coronary sinus (76 +/- 18.9 ms versus 35 +/- 16.1 in control patients, p less than 0.001). Repetitive atrial responses were recorded in 6 patients with AF and in 9 control subjects. Sinus nodal function abnormalities were detected in 6 of the patients with fibrillation. Patients with AF had a higher tendency than control subjects to develop slow intraatrial conduction, as well as shorter effective refractory periods. Since both features would favor reentry, they may be the electrophysiologic manifestations of the abnormalities making these patients prone to atrial reentrant arrhythmias. Repetitive atrial responses were of no predictive value. Sinus nodal dysfunction was frequently found, but was not essential for the occurrence of AF.

  18. Novel Percutaneous Epicardial Autonomic Modulation in the Canine for Atrial Fibrillation: Results of an Efficacy and Safety Study

    PubMed Central

    Madhavan, Malini; Venkatachalam, K. L.; Swale, Matthew J.; DeSimone, Christopher V.; Gard, Joseph J.; Johnson, Susan B.; Suddendorf, Scott H.; Mikell, Susan B.; Ladewig, Dorothy J.; Nosbush, Toni Grabinger; Danielsen, Andrew J.; Knudson, Mark; Asirvatham, Samuel J.

    2016-01-01

    Background Endocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters. Methods Phase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n=10). Phase 2: Percutaneous epicardial ablation of GP was done in 6 dogs using the most efficacious modality identified in phase 1 using 2 novel catheters. Results Phase 1: DC in varying doses [blocking (7 -12μA), electroporation (300-500μA), ablation (3000- 7500μA)], radiofrequency ablation (25–50 W), ultrasound (1.5MHz), and alcohol (2-5ml) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5 and 5/7 GP sites. DC (500–5000μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation (VF) during DC ablation at 5000 μA. Programmed stimulation induced AF in 6 dogs pre-ablation and no atrial arrhythmia in 3, flutter in 1 and AF in 1 post-ablation. Heart rate, blood pressure, effective atrial refractory period and local atrial electrogram amplitude did not change significantly post-ablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium. Conclusion Percutaneous epicardial ablation of GP using direct current and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of atrial fibrillation in order to minimize additional atrial myocardial ablation. PMID:26854009

  19. Identification and Characterization of Sites Where Persistent Atrial Fibrillation Is Terminated by Localized Ablation.

    PubMed

    Zaman, Junaid A B; Sauer, William H; Alhusseini, Mahmood I; Baykaner, Tina; Borne, Ryan T; Kowalewski, Christopher A B; Busch, Sonia; Zei, Paul C; Park, Shirley; Viswanathan, Mohan N; Wang, Paul J; Brachmann, Johannes; Krummen, David E; Miller, John M; Rappel, Wouter Jan; Narayan, Sanjiv M; Peters, Nicholas S

    2018-01-01

    The mechanisms by which persistent atrial fibrillation (AF) terminates via localized ablation are not well understood. To address the hypothesis that sites where localized ablation terminates persistent AF have characteristics identifiable with activation mapping during AF, we systematically examined activation patterns acquired only in cases of unequivocal termination by ablation. We recruited 57 patients with persistent AF undergoing ablation, in whom localized ablation terminated AF to sinus rhythm or organized tachycardia. For each site, we performed an offline analysis of unprocessed unipolar electrograms collected during AF from multipolar basket catheters using the maximum -dV/dt assignment to construct isochronal activation maps for multiple cycles. Additional computational modeling and phase analysis were used to study mechanisms of map variability. At all sites of AF termination, localized repetitive activation patterns were observed. Partial rotational circuits were observed in 26 of 57 (46%) cases, focal patterns in 19 of 57 (33%), and complete rotational activity in 12 of 57 (21%) cases. In computer simulations, incomplete segments of partial rotations coincided with areas of slow conduction characterized by complex, multicomponent electrograms, and variations in assigning activation times at such sites substantially altered mapped mechanisms. Local activation mapping at sites of termination of persistent AF showed repetitive patterns of rotational or focal activity. In computer simulations, complete rotational activation sequence was observed but was sensitive to assignment of activation timing particularly in segments of slow conduction. The observed phenomena of repetitive localized activation and the mechanism by which local ablation terminates putative AF drivers require further investigation. © 2018 American Heart Association, Inc.

  20. Spatial Resolution Requirements for Accurate Identification of Drivers of Atrial Fibrillation

    PubMed Central

    Roney, Caroline H.; Cantwell, Chris D.; Bayer, Jason D.; Qureshi, Norman A.; Lim, Phang Boon; Tweedy, Jennifer H.; Kanagaratnam, Prapa; Vigmond, Edward J.; Ng, Fu Siong

    2017-01-01

    Background— Recent studies have demonstrated conflicting mechanisms underlying atrial fibrillation (AF), with the spatial resolution of data often cited as a potential reason for the disagreement. The purpose of this study was to investigate whether the variation in spatial resolution of mapping may lead to misinterpretation of the underlying mechanism in persistent AF. Methods and Results— Simulations of rotors and focal sources were performed to estimate the minimum number of recording points required to correctly identify the underlying AF mechanism. The effects of different data types (action potentials and unipolar or bipolar electrograms) and rotor stability on resolution requirements were investigated. We also determined the ability of clinically used endocardial catheters to identify AF mechanisms using clinically recorded and simulated data. The spatial resolution required for correct identification of rotors and focal sources is a linear function of spatial wavelength (the distance between wavefronts) of the arrhythmia. Rotor localization errors are larger for electrogram data than for action potential data. Stationary rotors are more reliably identified compared with meandering trajectories, for any given spatial resolution. All clinical high-resolution multipolar catheters are of sufficient resolution to accurately detect and track rotors when placed over the rotor core although the low-resolution basket catheter is prone to false detections and may incorrectly identify rotors that are not present. Conclusions— The spatial resolution of AF data can significantly affect the interpretation of the underlying AF mechanism. Therefore, the interpretation of human AF data must be taken in the context of the spatial resolution of the recordings. PMID:28500175

  1. Real-Time Rotational Activity Detection in Atrial Fibrillation

    PubMed Central

    Ríos-Muñoz, Gonzalo R.; Arenal, Ángel; Artés-Rodríguez, Antonio

    2018-01-01

    Rotational activations, or spiral waves, are one of the proposed mechanisms for atrial fibrillation (AF) maintenance. We present a system for assessing the presence of rotational activity from intracardiac electrograms (EGMs). Our system is able to operate in real-time with multi-electrode catheters of different topologies in contact with the atrial wall, and it is based on new local activation time (LAT) estimation and rotational activity detection methods. The EGM LAT estimation method is based on the identification of the highest sustained negative slope of unipolar signals. The method is implemented as a linear filter whose output is interpolated on a regular grid to match any catheter topology. Its operation is illustrated on selected signals and compared to the classical Hilbert-Transform-based phase analysis. After the estimation of the LAT on the regular grid, the detection of rotational activity in the atrium is done by a novel method based on the optical flow of the wavefront dynamics, and a rotation pattern match. The methods have been validated using in silico and real AF signals. PMID:29593566

  2. Verapamil eliminates the hierarchical nature of activation frequencies from the pulmonary veins to the atria during paroxysmal atrial fibrillation.

    PubMed

    Kushiyama, Yasunori; Osaka, Toshiyuki; Yokoyama, Eriko; Hasebe, Hideyuki; Kuroda, Yusuke; Kamiya, Kaichiro; Kodama, Itsuo

    2010-05-01

    There is evidence that verapamil promotes the persistence of paroxysmal atrial fibrillation (AF). Little is known about the underlying mechanisms. The purpose of this study was to determine the effect of verapamil on dominant frequencies (DFs) in the pulmonary veins (PVs) and atria during paroxysmal AF with reference to its potential arrhythmogenicity. Forty-three patients with paroxysmal AF were studied. Bipolar electrograms were recorded simultaneously during AF from the right atrial free wall (RAFW), coronary sinus (CS) and three PVs, or two PVs and the left atrial appendage (LAA). The DFs were obtained by fast Fourier transform analysis before and after infusion of verapamil (0.1 mg/kg, intravenously). At baseline, the maximum DF among the PVs (6.9 +/- 0.9 Hz) was significantly higher than the DF in the RAFW (6.2 +/- 0.7 Hz), CS (5.7 +/- 0.5 Hz), or LAA (5.9 +/- 0.7 Hz) (P<.01); there was a substantial PV-to-atrial DF gradient (RAFW 0.7 +/- 0.9, CS 1.1 +/- 0.7, LAA 0.7 +/- 0.9 Hz). Verapamil increased the atrial DF to 6.9 +/- 0.8, 6.6 +/- 0.7, and 7.2 +/- 1.0 Hz in the RAFW, CS, and LAA, respectively (P<.0001) but did not affect the maximum PV DF (7.1 +/- 0.7 Hz). The PV-to-atrial DF gradient was eliminated after verapamil (RAFW 0.2 +/- 0.8, CS 0.5 +/- 0.6, LAA -0.4 +/- 0.8 Hz; P<.01 vs. baseline). Verapamil increases the activation frequency in the atria but not in the PVs, eliminating the PV-to-atrial DF gradient during paroxysmal AF. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Analysis and visualization of intracardiac electrograms in diagnosis and research: Concept and application of KaPAVIE.

    PubMed

    Oesterlein, Tobias Georg; Schmid, Jochen; Bauer, Silvio; Jadidi, Amir; Schmitt, Claus; Dössel, Olaf; Luik, Armin

    2016-04-01

    Progress in biomedical engineering has improved the hardware available for diagnosis and treatment of cardiac arrhythmias. But although huge amounts of intracardiac electrograms (EGMs) can be acquired during electrophysiological examinations, there is still a lack of software aiding diagnosis. The development of novel algorithms for the automated analysis of EGMs has proven difficult, due to the highly interdisciplinary nature of this task and hampered data access in clinical systems. Thus we developed a software platform, which allows rapid implementation of new algorithms, verification of their functionality and suitable visualization for discussion in the clinical environment. A software for visualization was developed in Qt5 and C++ utilizing the class library of VTK. The algorithms for signal analysis were implemented in MATLAB. Clinical data for analysis was exported from electroanatomical mapping systems. The visualization software KaPAVIE (Karlsruhe Platform for Analysis and Visualization of Intracardiac Electrograms) was implemented and tested on several clinical datasets. Both common and novel algorithms were implemented which address important clinical questions in diagnosis of different arrhythmias. It proved useful in discussions with clinicians due to its interactive and user-friendly design. Time after export from the clinical mapping system to visualization is below 5min. KaPAVIE(2) is a powerful platform for the development of novel algorithms in the clinical environment. Simultaneous and interactive visualization of measured EGM data and the results of analysis will aid diagnosis and help understanding the underlying mechanisms of complex arrhythmias like atrial fibrillation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. High correlation of estimated local conduction velocity with natural logarithm of bipolar electrogram amplitude in the reentry circuit of atrial flutter.

    PubMed

    Itoh, Taihei; Kimura, Masaomi; Sasaki, Shingo; Owada, Shingen; Horiuchi, Daisuke; Sasaki, Kenichi; Ishida, Yuji; Takahiko, Kinjo; Okumura, Ken

    2014-04-01

    Low conduction velocity (CV) in the area showing low electrogram amplitude (EA) is characteristic of reentry circuit of atypical atrial flutter (AFL). The quantitative relationship between CV and EA remains unclear. We characterized AFL reentry circuit in the right atrium (RA), focusing on the relationship between local CV and bipolar EA on the circuit. We investigated 26 RA AFL (10 with typical AFL; 10 atypical incisional AFL; 6 atypical nonincisional AFL) using CARTO system. By referring to isochronal and propagation maps delineated during AFL, points activated faster on the circuit were selected (median, 7 per circuit). At the 196 selected points obtained from all patients, local CV measured between the adjacent points and bipolar EA were analyzed. There was a highly significant correlation between local CV and natural logarithm of EA (lnEA) (R(2) = 0.809, P < 0.001). Among 26 AFL, linear regression analysis of mean CV, calculated by dividing circuit length (152.3 ± 41.7 mm) by tachycardia cycle length (TCL) (median 246 msec), and mean lnEA, calculated by dividing area under curve of lnEA during one tachycardia cycle by TCL, showed y = 0.695 + 0.191x (where: y = mean CV, x = lnEA; R(2) = 0.993, P < 0.001). Local CV estimated from EA with the use of this formula showed a highly significant linear correlation with that measured by the map (R(2) = 0.809, P < 0.001). The lnEA and estimated local CV show a highly positive linear correlation. CV is possibly estimated by EA measured by CARTO mapping. © 2013 Wiley Periodicals, Inc.

  5. Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

    PubMed

    Knight, Bradley; Ayers, Gregory M; Cohen, Todd J

    2008-05-01

    Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial and right ventricular sites (p > 0.05). His-bundle electrograms were equal in amplitude and timing. Further, the remote navigation catheter was able to be disengaged, manually manipulated, then reengaged in the robot without issue. There was no evidence of perforation. The Catheter Robotics remote catheter manipulation system, which uses conventional EP catheters and introducer sheaths, appears to be safe and effective at directing EP catheters to intracardiac sites and achieving pacing thresholds and electrograms equivalent to manually placed catheters. Further clinical studies are needed to confirm these observations.

  6. Percutaneous ligation of the left atrial appendage results in atrial electrical substrate modification.

    PubMed

    Syed, Faisal F; Rangu, Venu; Bruce, Charles J; Johnson, Susan B; Danielsen, Andrew; Gilles, Emily J; Ladewig, Dorothy J; Mikell, Susan B; Berhow, Steven; Wahnschaffe, Douglas; Suddendorf, Scott H; Asirvatham, Samuel J; Friedman, Paul A

    2015-03-01

    Debulking of electrically active atrial tissue may reduce the mass of fibrillating tissue during atrial fibrillation, eliminate triggers, and promote maintenance of normal sinus rhythm (NSR). We investigated whether left atrial appendage (LAA) ligation results in modification of atrial electrical substrate. Healthy male mongrel dogs (N = 20) underwent percutaneous epicardial LAA ligation. The ligation system grabber recorded LAA local electrograms (EGM) continuously before, during, and after closure. Successful ligation with a preloaded looped suture was confirmed intraprocedurally by LAA Doppler flow cessation on transesophageal echocardiography (TEE) and loss of LAA electrical activity, and after procedure by direct necropsic visualization. P-wave duration on surface electrocardiograms was measured immediately before and after LAA closure. Percent P-wave duration reduction was correlated with preclosure LAA internal dimensions measured by TEE and external dimensions measured on necropsy specimens to investigate associations of LAA geometry with the extent of electrical substrate modification. LAA ligation was successful in all dogs and accompanied by loss of LAA EGM. P-wave duration reduced immediately on ligation (mean 75 ms preligation to 63 ms postligation; mean difference ± standard error, 12 ± 1 ms; P < 0.0001). Percent P-wave reduction was associated with larger LAA longitudinal cross-sectional area (R(2) = 0.263, P = 0.04) and smaller external circumference (R(2) = 0.687, P = 0.04). All dogs were in sinus rhythm. Percutaneous LAA ligation results in its acute electrical isolation and atrial electrical substrate modification, the degree of which is associated with LAA geometry. These electrical changes raise the possibility that LAA ligation may promote NSR by removing LAA substrate and triggers. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Determination of inadvertent atrial capture during para-Hisian pacing.

    PubMed

    Obeyesekere, Manoj; Leong-Sit, Peter; Skanes, Allan; Krahn, Andrew; Yee, Raymond; Gula, Lorne J; Bennett, Matthew; Klein, George J

    2011-08-01

    Inadvertent capture of the atrium will lead to spurious results during para-Hisian pacing. We sought to establish whether the stimulation-to-atrial electrogram interval at the proximal coronary sinus (stim-PCS) or high right atrium (stim-HRA) could signal inadvertent atrial capture. Para-Hisian pacing with and without intentional atrial capture was performed in 31 patients. Stim-HRA and stim-PCS intervals were measured with atrial capture, His plus para-Hisian ventricular (H+V) capture, and para-Hisian ventricular (V) capture alone. The mean stim-HRA interval was significantly shorter with atrial capture (66 ± 18 ms) than with H+V (121 ± 27 ms, P < 0.001) or V capture alone (174 ± 38 ms, P < 0.001). The mean stim-PCS interval was significantly shorter with atrial capture (51 ± 16 ms) than with H+V (92 ± 22 ms, P<0.001) or V capture alone (146 ± 33 ms, P < 0.001). A stim-PCS < 60 ms (stim-HRA < 70 ms) was observed only with atrial capture. A stim-PCS >90 ms (stim-HRA >100 ms) was observed only in the absence of atrial capture. A stim-HRA of < 85 ms was highly specific and stim-PCS of < 85 ms highly sensitive at identifying atrial capture. Stim-HRA intervals of 75 to 97 ms and stim-PCS intervals of 65 to 88 ms were observed with either atrial, His, or para-Hisian ventricular capture without atrial capture. In this overlap zone, all patients demonstrated a stim-PCS or stim-HRA interval prolongation of at least 20 ms when the catheter was advanced to avoid deliberate atrial pacing. The QRS morphology was of limited value in distinguishing atrial capture due to concurrent ventricular or H+V capture, as observed in 20 of 31 (65%) patients. Stim-PCS and stim-HRA intervals can be used to monitor for inadvertent atrial capture during para-Hisian pacing. A stim-PCS < 60 ms (or stim-HRA < 70 ms) and stim-PCS > 90 ms (or stim-HRA > 100 ms) were observed only with and without atrial capture, respectively, but there was significant overlap between these values. Deliberate atrial capture and loss of capture reliably identifies atrial capture regardless of intervals.

  8. Effect of pilsicainide on dominant frequency in the right and left atria and pulmonary veins during atrial fibrillation: association with its atrial fibrillation terminating effect.

    PubMed

    Horiuchi, Daisuke; Iwasa, Atsushi; Sasaki, Kenichi; Owada, Shingen; Kimura, Masaomi; Sasaki, Shingo; Okumura, Ken

    2009-04-17

    Dominant frequency reflects the peak cycle length of atrial fibrillation. In 34 patients with atrial fibrillation, bipolar electrograms were recorded from multiple atrial sites and pulmonary veins and the effect of pilsicainide, class Ic antiarrhythmic drug, on dominant frequency was examined. At baseline, mean dominant frequencies (Hz) in the right and left atria, coronary sinus and right and left superior pulmonary veins were 5.87 +/- 0.76, 6.08 +/- 0.60, 5.65 +/- 0.95, 6.12 +/- 0.88 and 6.59 +/- 0.89, respectively (P < 0.05, left superior pulmonary vein vs right atrium and coronary sinus). After pilsicainide (1.0 mg/kg/5 min), dominant frequency decreased at all sites in all patients. Atrial fibrillation was terminated at 5.9 +/- 2.2 min in 16 patients (Group A) with a decrease in the average of mean dominant frequencies at all sites from 5.80 +/- 0.72 to 3.57 +/- 0.63 Hz, was converted to atrial flutter at 7.3 +/- 1.4 min in 5 (Group B) with a decrease in the average dominant frequency from 5.83 +/- 0.48 to 3.08 +/- 0.19 Hz, and was not terminated in the other 13 (Group C) despite the average dominant frequency decrease from 6.59 +/- 0.76 to 4.42 +/- 0.52 Hz. In 14 of the 21 Groups A and B patients (67%), mean dominant frequencies at all recording sites were < 4.0 after pilsicainide, while they were < 4.0 in 1 of the 13 Group C patients (8%, P < 0.01). In conclusion, the degree of dominant frequency decrease by pilsicainide is closely related to its atrial fibrillation terminating effect: When dominant frequency in the atria decreases to < 4.0 Hz, atrial fibrillation is terminated with 93% positive and 63% negative predictive values.

  9. Radiofrequency catheter ablation in patients with symptomatic atrial flutter/tachycardia after orthotopic heart transplantation.

    PubMed

    Li, Yi-gang; Grönefeld, Gerian; Israel, Carsten; Lu, Shang-biao; Wang, Qun-shan; Hohnloser, Stefan H

    2006-12-20

    Atrial tachycardia or flutter is common in patients after orthotopic heart transplantation. Radiofrequency catheter ablation to treat this arrhythmia has not been well defined in this setting. This study was conducted to assess the incidence of various symptomatic atrial arrhythmias and the efficacy and safety of radiofrequency catheter ablation in these patients. Electrophysiological study and catheter ablation were performed in patients with symptomatic tachyarrhythmia. One Halo catheter with 20 poles was positioned around the tricuspid annulus of the donor right atrium, or positioned around the surgical anastomosis when it is necessary. Three quadripolar electrode catheters were inserted via the right or left femoral vein and positioned in the recipient atrium, the bundle of His position, the coronary sinus. Programmed atrial stimulation and burst pacing were performed to prove electrical conduction between the recipient and the donor atria and to induce atrial arrhythmias. Out of 55 consecutive heart transplantation patients, 6 males [(58 +/- 12) years] developed symptomatic tachycardias at a mean of (5 +/- 4) years after heart transplantation. Electrical propagation through the suture line between the recipient and the donor atrium was demonstrated during atrial flutter or during recipient atrium and donor atrium pacing in 2 patients. By mapping around the suture line, the earliest fragmented electrogram of donor atrium was assessed. This electrical connection was successfully ablated in the anterior lateral atrium in both patients. There was no electrical propagation through the suture line in the other 4 patients. Two had typical atrial flutter in the donor atrium which was successfully ablated by completing a linear ablation between the tricuspid annulus and the inferior vena cava. Two patients had atrial tachycardia which was ablated in the anterior septal and lateral donor atrium. There were no procedure-related complications. Patients were free of recurrent atrial tachyarrhythmias after a follow-up of (8 +/- 7) months. Four electrophysiological mechanisms have been found to contribute to the occurrence of symptomatic supraventricular arrhythmias following heart transplantation. Radiofrequency catheter ablation in patients with atrial flutter/tachycardia is feasible and safe after heart transplantation.

  10. Magnetic electroanatomical mapping for ablation of focal atrial tachycardias.

    PubMed

    Marchlinski, F; Callans, D; Gottlieb, C; Rodriguez, E; Coyne, R; Kleinman, D

    1998-08-01

    Uniform success for ablation of focal atrial tachycardias has been difficult to achieve using standard catheter mapping and ablation techniques. In addition, our understanding of the complex relationship between atrial anatomy, electrophysiology, and surface ECG P wave morphology remains primitive. The magnetic electroanatomical mapping and display system (CARTO) offers an on-line display of electrical activation and/or signal amplitude related to the anatomical location of the recorded sites in the mapped chamber. A window of electrical interest is established based on signals timed from an electrical reference that usually represents a fixed electrogram recording from the coronary sinus or the atrial appendage. This window of electrical interest is established to include atrial activation prior to the onset of the P wave activity associated with the site of origin of a focal atrial tachycardia. Anatomical and electrical landmarks are defined with limited fluoroscopic imaging support and more detailed global chamber and more focal atrial mapping can be performed with minimal fluoroscopic guidance. A three-dimensional color map representing atrial activation or voltage amplitude at the magnetically defined anatomical sites is displayed with on-line data acquisition. This display can be manipulated to facilitate viewing from any angle. Altering the zoom control, triangle fill threshold, clipping plane, or color range can all enhance the display of a more focal area of interest. We documented the feasibility of using this single mapping catheter technique for localizing and ablating focal atrial tachycardias. In a consecutive series of 8 patients with 9 focal atrial tachycardias, the use of the single catheter CARTO mapping system was associated with ablation success in all but one patient who had a left atrial tachycardia localized to the medial aspect of the orifice of the left atrial appendage. Only low power energy delivery was used in this patient because of the unavailability of temperature monitoring in the early version of the Navistar catheter, the location of the arrhythmia, and the history of arrhythmia control with flecainide. No attempt was made to limit fluoroscopy time in our study population. Nevertheless, despite data acquisition from 120-320 anatomically distinct sites during global and more detailed focal atrial mapping, total fluoroscopy exposure was typically < 30 minutes and was as little as 12 minutes. The detailed display capabilities of the CARTO system appear to offer the potential of enhancing our understanding of atrial anatomy, atrial activation, and their relationship to surface ECG P wave morphology during focal atrial tachycardias.

  11. Outcome of stand-alone thoracoscopic epicardial left atrial posterior box isolation with bipolar radiofrequency energy for longstanding persistent atrial fibrillation.

    PubMed

    Compier, M G; Braun, J; Tjon, A; Zeppenfeld, K; Klautz, R J M; Schalij, M J; Trines, S A

    2016-02-01

    Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block. Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings. Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs. Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.

  12. Left ventricular approach for recording His bundle potential in man.

    PubMed

    Lee, Y S; Lien, W P

    1975-06-01

    The electrical potentials of the His bundle (HB) were recorded from the left ventricular endocardial surface in 28 patients ranging from 16 to 63 years of age. In 14 of the patients the left bundle branch (LB) potentials were also obtained. Placement of a bipolar electrode catheter tip toward the interventricular septum, right at and also 1 to 2 cm below the aortic valve, resulted in stable recordings of both potentials in successive cardiac cycles even at performing atrial or HB pacing from the right heart. The following intervals were measured in milliseconds (msec): P-A, A-H, H, H-V, LB, and LB-V. The average values in 12 patients (average age 26 plus or minus 7 years and average heart rate 90 plus or minus 16 beats per minute) with normal A-V conduction were as follows: P-A 28 plus or minus 7, A-H 76 plus or minus 16, H 19 plus or minus 3 and H-V 45 plus or minus 6 msec. The average values for LB and LB-V in 10 of these 12 patients were 15 plus or minus 3 and 25 plus or minus 3 msec respectively. Validation of the His bundle electrogram (HBE) from the left ventricular endocardial surface was based on simultaneous recordings of the intracardiac electrograms from both left and right sides of the heart in 18 patients. The individual average values for the intervals obtained from both sides of the heart in these patients were statistically not different, except that the H potential was slightly longer in duration fr m the left heart (P equals 0.05). Among these, 16 showed simultaneous onset of the H potentials, and the LB-V and RB-V conduction times from comparable points were almost the same. Indications for the left sided electro-physiologic studies include the following situations: (a) inability to record H from the right of the heart; (b) giant right atrium; and (c) possibly during atrial fibrillation.

  13. Does a patent foramen ovale matter when using a remote-controlled magnetic system for pulmonary vein isolation?

    PubMed

    Gate-Martinet, Alexie; Da Costa, Antoine; Romeyer-Bouchard, Cécile; Bisch, Laurence; Levallois, Marie; Isaaz, Karl

    2014-02-01

    Pulmonary vein isolation (PVI) takes longer when using a patent foramen ovale (PFO) compared with a transseptal puncture in paroxysmal atrial fibrillation (AF) with manual catheter ablation. To our knowledge, no data exist concerning the impact of a PFO on AF ablation procedure variables when using a remote magnetic navigation (RMN) system. To assess the impact of a PFO when using an RMN system in patients requiring AF ablation. Between December 2011 and December 2012, catheter ablation was performed remotely using the CARTO(®) 3 system in 167 consecutive patients who underwent PVI for symptomatic drug-refractory AF. The radiofrequency generator was set to a fixed power ≤ 35 W. The primary endpoint was wide-area circumferential PVI confirmed by spiral catheter recording during ablation for all patients and including additional lesion lines (left atrial roof) or complex fractionated atrial electrograms for persistent AF. Secondary endpoints included procedural data. Mean age 58±10 years; 18% women; 107 (64%) patients with symptomatic paroxysmal AF; 60 (36%) with persistent AF; CHA2DS2-VASc score 1.2 ± 1. The PFO presence was evidenced in 49/167 (29.3%) patients during the procedure but in only 26/167 (16%) by transoesophageal echocardiography. Median procedure time 2.5 ± 1 hours; median total X-ray exposure time 14 ± 7 minutes; transseptal puncture and catheter positioning time 7.5 ± 5 minutes; left atrium electroanatomical reconstruction time 3 ± 2.3 minutes; catheter ablation time 3 ± 3 minutes. No procedure time or X-ray exposure differences were observed between patients with or without a PFO during magnetic navigation catheter ablation. X-ray exposure time was significantly reduced using a PFO compared with double transseptal puncture access. A PFO does not affect magnetic navigation during AF ablation; procedure times and X-ray exposure were similar. Septal catheter probing is mandatory to limit X-ray exposure and prevent potential complications. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. ACUTE TERMINATION OF HUMAN ATRIAL FIBRILLATION BY IDENTIFICATION AND CATHETER ABLATION OF LOCALIZED ROTORS AND SOURCES

    PubMed Central

    Shivkumar, Kalyanam; Ellenbogen, Kenneth A.; Hummel, John D.; Miller, John M.; Steinberg, Jonathan S.

    2012-01-01

    Catheter ablation of atrial fibrillation (AF) currently relies on eliminating triggers, and no reliable method exists to map the arrhythmia itself to identify ablation targets. The aim of this multicenter study was to define the use of Focal Impulse and Rotor Modulation (FIRM) for identifying ablation targets. METHODS We prospectively enrolled the first (n=14, 11 males) consecutive patients undergoing FIRM guided ablation for persistent (n=11) and paroxysmal AF at 5 centers. A 64 pole basket catheter was used for panoramic right and left atrial mapping during AF. AF electrograms were analyzed using a novel system to identify sustained rotors (spiral waves), or focal beats (centrifugal activation to surrounding atrium). Ablation was performed first at identified sources. The primary endpoints were acute AF termination or organization (>10 % cycle length prolongation). Conventional ablation was performed only after FIRM guided ablation. RESULTS 12/14 cases were mapped. AF sources were demonstrated in all patients (average of 1.9±0.8 per patient). Sources were left atrial in 18 cases, and right atrial in 5 cases, and 21/23 were rotors. FIRM guided ablation achieved the acute endpoint in all patients, consisting of AF termination in n=8 (4.9±3.9 min at the primary source), and organization in n=4. Total FIRM time for all patients was 12.3±8.6 min. CONCLUSIONS FIRM guided ablation revealed localized AF rotors/focal sources in patients with paroxysmal, persistent and longstanding persistent AF. Brief targeted FIRM guided ablation at a priori identified sites terminated or substantially organized AF in all cases prior to any other ablation. PMID:23130890

  15. Left atrial function in heart failure with impaired and preserved ejection fraction.

    PubMed

    Fang, Fang; Lee, Alex Pui-Wai; Yu, Cheuk-Man

    2014-09-01

    Left atrial structural and functional changes in heart failure are relatively ignored parts of cardiac assessment. This review illustrates the pathophysiological and functional changes in left atrium in heart failure as well as their prognostic value. Heart failure can be divided into those with systolic dysfunction and heart failure with preserved ejection fraction (HFPEF). Left atrial enlargement and dysfunction commonly occur in systolic heart failure, in particular, in idiopathic dilated cardiomyopathy. Atrial enlargement and dysfunction also carry important prognostic value in systolic heart failure, independently of known parameters such as left ventricular ejection fraction. In HFPEF, there is evidence of left atrial enlargement, impaired atrial compliance, and reduction of atrial pump function. This occurs not only at rest but also during exercise, indicating significant impairment of atrial contractile reserve. Furthermore, atrial dyssynchrony is common in HFPEF. These factors further contribute to the development of new onset or progression of atrial arrhythmias, in particular, atrial fibrillation. Left atrial function is an integral part of cardiac function and its structural and functional changes in heart failure are common. As changes of left atrial structure and function have different clinical implications in systolic heart failure and HFPEF, routine assessment is warranted.

  16. A comparison of the electrophysiologic and electroanatomic characteristics between the right and left atrium in persistent atrial fibrillation: Is the right atrium a window into the left?

    PubMed

    Prabhu, Sandeep; Voskoboinik, Aleksandr; McLellan, Alex J A; Peck, Kah Y; Pathik, Bhupesh; Nalliah, Chrishan J; Wong, Geoff R; Azzopardi, Sonia M; Lee, Geoffrey; Mariani, Justin; Ling, Liang-Han; Taylor, Andrew J; Kalman, Jonathan M; Kistler, Peter M

    2017-10-01

    The right atrium (RA) is readily accessible; however, it is unclear whether changes in the RA are representative of the LA. We performed detailed biatrial electroanatomic mapping to determine the electrophysiological relationship between the atria. Consecutive patients with persistent AF underwent biatrial electroanatomical mapping with a contact force catheter acquiring points with a CF >10 g prior to ablation. Points were analyzed for tissue voltage, complex electrograms, low voltage (<0.5 mV), scar (<0.05 mV), and conduction velocity (CV). Forty patients (mean age 59 ± 9.2 years, AF duration 12.9 ± 9.2 months, LA area: 28 ± 5.2, RA area: 25 ± 6.4 mm 2 , LVEF: 44 ± 15%) underwent mapping during CS pacing. Bipolar voltage (R = 0.57, P <0.001), unipolar voltage (R = 0.68, P <0.001), low voltage (<0.5 nV) (R = 0.48, P = 0.002), fractionation (R = 0.73, P <0.001), and CV (R = 0.49, P = 0.001) correlated well between atria. There was no difference in global bipolar voltage (LA 1.89 ± 0.77 vs. RA 1.77 ± 0.57 mV, P = 0.57); complex electrograms (LA 20% vs. RA 20%, P = 0.99) or low voltage (LA 15% vs. RA 16%, P = 0.84). Global unipolar voltage was significantly higher in the LA compared to the RA (2.95 ± 1.14 vs. 2.28 ± 0.65 mV, P = 0.002) and CV was significantly slower in the RA compared to the LA (0.93 ± 0.15 m/s vs. 1.01 ± 0.19 m/s, P = 0.001). AF is associated with remodeling processes affecting both atria. The more accessible RA provides an insight into the biatrial process associated with AF in various disease states without trans-septal access. © 2017 Wiley Periodicals, Inc.

  17. Temporal Stability of Rotors and Atrial Activation Patterns in Persistent Human Atrial Fibrillation: A High-Density Epicardial Mapping Study of Prolonged Recordings.

    PubMed

    Walters, Tomos E; Lee, Geoffrey; Morris, Gwilym; Spence, Steven; Larobina, Marco; Atkinson, Victoria; Antippa, Phillip; Goldblatt, John; Royse, Alistair; O'Keefe, Michael; Sanders, Prashanthan; Morton, Joseph B; Kistler, Peter M; Kalman, Jonathan M

    This study aimed to determine the spatiotemporal stability of rotors and other atrial activation patterns over 10 min in longstanding, persistent AF, along with the relationship of rotors to short cycle-length (CL) activity. The prevalence, stability, and mechanistic importance of rotors in human atrial fibrillation (AF) remain unclear. Epicardial mapping was performed in 10 patients undergoing cardiac surgery, with bipolar electrograms recorded over 10 min using a triangular plaque (area: 6.75 cm 2 ; 117 bipoles; spacing: 2.5 mm) applied to the left atrial posterior wall (n = 9) and the right atrial free wall (n = 4). Activations were identified throughout 6 discrete 10-s segments of AF spanning 10 min, and dynamic activation mapping was performed. The distributions of 4,557 generated activation patterns within each mapped region were compared between the 6 segments. The dominant activation pattern was the simultaneous presence of multiple narrow wave fronts (26%). Twelve percent of activations represented transient rotors, seen in 85% of mapped regions with a median duration of 3 rotations. A total of 87% were centered on an area of short CL activity (<100 ms), although such activity had a positive predictive value for rotors of only 0.12. The distribution of activation patterns and wave-front directionality were highly stable over time, with a single dominant pattern within a 10-s AF segment recurring across all 6 segments in 62% of mapped regions. In patients with longstanding, persistent AF, activation patterns are spatiotemporally stable over 10 min. Transient rotors can be demonstrated in the majority of mapped regions, are spatiotemporally associated with short CL activity, and, when recurrent, demonstrate anatomical determinism. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Impact of acute atrial fibrillation termination and prolongation of atrial fibrillation cycle length on the outcome of ablation of persistent atrial fibrillation: A substudy of the STAR AF II trial.

    PubMed

    Kochhäuser, Simon; Jiang, Chen-Yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan; Verma, Atul

    2017-04-01

    Controversy exists about the impact of acute atrial fibrillation (AF) termination and prolongation of atrial fibrillation cycle length (AFCL) during ablation on long-term procedural outcome. The purpose of this study was to analyze the influence of AF termination and AFCL prolongation on freedom from AF in patients from the STAR AF II (Substrate and Trigger Ablation for Reduction of Atrial Fibrillation Trial-Part II) trial. Acute changes in AFCL and AF termination were collected during the index procedure of the STAR AF II trial and compared to recurrence of AF at 18 months. Recurrence was assessed by ECG, Holter (3, 6, 9, 12, 18 months), and weekly transtelephonic ECG monitoring for 18 months. AF terminated in 8% of the pulmonary vein isolation (PVI) arm, 45% in the PVI+complex electrogram arm, and 22% of the PVI+linear ablation arm (P <.001), but freedom from AF did not differ among the 3 groups (P = .15). Freedom from AF was significantly higher in patients who presented to the laboratory in sinus rhythm (SR) compared to those without AF termination (63% vs 44%, P = .007). Patients with AF termination had an intermediate outcome (53%) that was not significantly different from those in SR (P = .84) or those who did not terminate (P = .08). AF termination was a univariable predictor of success (P = .007), but by multivariable analysis, presence of early SR was the strongest predictor of success (hazard ratio 0.67, P = .004). Prolongation of AFCL was not predictive of 18-month freedom from AF. Acute AF termination and prolongation in AFCL did not consistently predict 18-month freedom from AF. Presence of SR before or early during the ablation was the strongest predictor of better outcome. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. Electrophysiological effects of acute atrial stretch on persistent atrial fibrillation in patients undergoing open heart surgery.

    PubMed

    Elvan, Arif; Adiyaman, Ahmet; Beukema, Rypko J; Sie, Hauw T; Allessie, Maurits A

    2013-03-01

    The electrophysiologic effects of acute atrial dilatation and dedilatation in humans with chronic atrial fibrillation remains to be elucidated. To study the electrophysiological effects of acute atrial dedilatation and subsequent dilatation in patients with long-standing persistent atrial fibrillation (AF) with structural heart disease undergoing elective cardiac surgery. Nine patients were studied. Mean age was 71 ± 10 years, and left ventricular ejection was 46% ± 6%. Patients had at least moderate mitral valve regurgitation and dilated atria. After sternotomy and during extracorporal circulation, mapping was performed on the beating heart with 2 multielectrode arrays (60 electrodes each, interelectrode distance 1.5 mm) positioned on the lateral wall of the right atrium (RA) and left atrium (LA). Atrial pressure and size were altered by modifying extracorporal circulation. AF electrograms were recorded at baseline after dedilation and after dilatation of the atria afterward. At baseline, the median AF cycle length (mAFCL) was 184 ± 27 ms in the RA and 180 ± 17 ms in the LA. After dedilatation, the mAFCL shortened significantly to 168 ± 13 ms in the RA and to 168 ± 20 ms in the LA. Dilatation lengthened mAFCL significantly to 189 ± 17 ms in the RA and to 185 ± 23 ms in the LA. Conduction block (CB) at baseline was 14.3% ± 3.6% in the RA and 17.3% ± 5.5% in the LA. CB decreased significantly with dedilatation to 7.4% ± 2.9% in the RA and to 7.9% ± 6.3% in the LA. CB increased significantly with dilatation afterward to 15.0% ± 8.3% in the RA and to 18.5% ± 16.0% in the LA. Acute dedilatation of the atria in patients with long-standing persistent AF causes a decrease in the mAFCL in both atria. Subsequent dilatation increased the mAFCL. The amount of CB decreased with dedilatation and increased with dilatation afterward in both atria. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Atrial Function after the Atrial Switch Operation for Transposition of the Great Arteries: Comparison with Arterial Switch and Normals by Cardiovascular Magnetic Resonance.

    PubMed

    Franzoso, Francesca D; Wohlmuth, Christoph; Greutmann, Matthias; Kellenberger, Christian J; Oxenius, Angela; Voser, Eva M; Valsangiacomo Buechel, Emanuela R

    2016-09-01

    The atria serve as reservoir, conduit, and active pump for ventricular filling. The performance of the atrial baffles after atrial switch repair for transposition of the great arteries may be abnormal and impact the function of the systemic right ventricle. We sought to assess atrial function in patients after atrial repair in comparison to patients after arterial switch repair (ASO) and to controls. Using magnetic resonance imaging, atrial volumes and functional parameters were measured in 17 patients after atrial switch repair, 9 patients after ASO and 10 healthy subjects. After the atrial switch operation, the maximum volume of the pulmonary venous atrium was significantly enlarged, but not of the systemic venous atrium. In both patients groups, independently from the surgical technique used, the minimum atrial volumes were elevated, which resulted in a decreased total empting fraction compared with controls (P < .01). The passive empting volume was diminished for right atrium, but elevated for left atrium after atrial switch and normal for left atrium after ASO; however, the passive empting fraction was diminished for both right atrium and left atrium after both operations (P < .01). The active empting volume was the most affected parameter in both atria and both groups and active empting fractions were highly significantly reduced compared with controls. Atrial function is abnormal in all patients, after atrial switch and ASO repair. The cyclic volume changes, that is, atrial filling and empting, are reduced when compared with normal subjects. Thus, the atria have lost part of their capacity to convert continuous venous flow into a pulsatile ventricular filling. The function of the pulmonary venous atrium, acting as preload for the systemic right ventricle, after atrial switch is altered the most. © 2015 Wiley Periodicals, Inc.

  1. Greater nighttime blood pressure variability is associated with left atrial enlargement in atrial fibrillation patients with preserved ejection fraction.

    PubMed

    Norioka, Naoki; Iwata, Shinichi; Ito, Asahiro; Tamura, Soichiro; Kawai, Yu; Nonin, Shinichi; Ishikawa, Sera; Doi, Atsushi; Hanatani, Akihisa; Yoshiyama, Minoru

    2018-06-13

    Left atrial enlargement is an independent risk factor for ischemic stroke in patients with atrial fibrillation. Little is known regarding the association between nighttime blood pressure variability and left atrial enlargement in patients with atrial fibrillation and preserved ejection fraction. The study population consisted of 140 consecutive patients with atrial fibrillation (mean age 64 ± 10 years) with preserved ejection fraction (≥50%). Nighttime blood pressure was measured at hourly intervals, using a home blood pressure monitoring device. Nighttime blood pressure variability was expressed as the standard deviation of all readings. Left atrial volume index was measured using the modified Simpson's biplane method with transthoracic echocardiography. Multiple regression analysis indicated that nighttime mean systolic/diastolic blood pressure and its variability remained independently associated with left atrial enlargement after adjustment for age, sex, anti-hypertensive medication class, and left ventricular mass index (P < 0.01). When patients were divided into four groups according to nighttime blood pressure and its variability, the group with higher nighttime blood pressure and its variability had significantly larger left atrial volume than the group with lower nighttime blood pressure and its variability (46.6 ml/m 2 vs. 35.0 ml/m 2 , P < 0.0001). Higher nighttime blood pressure and its variability are associated with left atrial enlargement. The combination of nighttime blood pressure and its variability has additional predictive value for left atrial enlargement. Intensive intervention for these high-risk patients may avoid or delay progression of left atrial enlargement and reduce the risk of stroke.

  2. Factors associated with atrial fibrillation in rheumatic mitral stenosis.

    PubMed

    Pourafkari, Leili; Ghaffari, Samad; Bancroft, George R; Tajlil, Arezou; Nader, Nader D

    2015-01-01

    Atrial fibrillation is a complication of mitral valve stenosis that causes several adverse neurologic outcomes. Our objective was to establish a mathematical model to predict the risk of atrial fibrillation in patients with mitral stenosis. Of 819 patients with mitral stenosis who were screened, 603 were enrolled in the study and grouped according to whether they were in sinus rhythm or atrial fibrillation. Demographic, echocardiographic, and hemodynamic data were recorded. Logistic regression models were constructed to identify the relative risks for each contributing factor and calculate the probability of developing atrial fibrillation. Receiver operating characteristic curves were plotted. Two hundred (33%) patients had atrial fibrillation; this group was older, in a higher functional class, more likely to have suffered previous thromboembolic events, and had significantly larger left atrial diameters, lower ejection fractions, and lower left atrial appendage emptying flow velocity. The factors independently associated with atrial fibrillation were left atrial strain (odds ratio = 7.53 [4.47-12.69], p < 0.001), right atrial pressure (odds ratio = 1.09 [1.02-1.17], p = 0.01), age (odds ratio = 1.14 [1.05-1.25], p = 0.002), and ejection fraction (odds ratio = 0.92 [0.87-0.97], p = 0.003). The area under the curve for the combined receiver operating characteristic for this model was 0.90 ± 0.12. Age, right atrial pressure, ejection fraction, and left atrial strain can be used to construct a mathematical model to predict the development of atrial fibrillation in rheumatic mitral stenosis. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. [Catheter ablation of ectopic incessant atrial tachycardia using radiofrequency. Reversion of tachycardiomyopathy].

    PubMed

    de Paola, A A; Mendonça, A; Balbão, C E; Tavora, M Z; da Silva, R M; Hara, V M; Guiguer Júnior, N; Vattimo, A C; Souza, I A; Portugal, O P

    1993-10-01

    A 8-year-old female patient with refractory incessant atrial tachycardia, very symptomatic and with left ventricular ejection fraction of 0.25. Electrophysiological study and endocardial mapping localized the site of the origin of atrial tachycardia in the superior right atrium. In this site 2 applications of radiofrequency current (25V, 20 and 50 seconds) resulted in termination of the atrial tachycardia. She was discharged off antiarrhythmic drugs and after 2 months ejection fraction was 0.52. She was completely asymptomatic 6 months after ablation procedure.

  4. Prevention of atrial fibrillation by inter-atrial septum pacing guided by electrophysiological testing, in patients with delayed interatrial conduction.

    PubMed

    Manolis, A G; Katsivas, A G; Vassilopoulos, C; Koutsogeorgis, D; Louvros, N E

    2002-04-01

    Interatrial septum (IAS) pacing seems efficient in synchronizing atrial depolarization in patients (pts) with delayed inter-atrial conduction, but its clinical role in preventing atrial tachyarrhythmias is still debated. This study was conducted in order to evaluate the clinical efficacy of IAS pacing guided by pace mapping of the IAS, as an alternative treatment modality in pts with drug refractory paroxysmal atrial fibrillation (PAF). We evaluated 29 pts (13 male, 16 female, 60 +/- 11 years), with drug refractory PAF, normal sinus node function and prolonged inter-atrial conduction time (P wave 142 +/- 10 ms). Multipolar catheters were inserted and the electrograms from the high right atrium (HRA) and proximal, middle and distal coronary sinus (CS) were recorded. The IAS was paced from multiple sites. The site of IAS where the timing between HRA and distal CS was <20 ms was considered the most suitable for synchronizing the atria. This site was found to be superior to the CS os. near the fossa ovalis in all pts. An active fixation atrial lead was positioned at this site and a standard lead was placed in the right ventricle. During IAS pacing, the P wave duration decreased significantly to 107 +/- 15 ms (P<0.001). At implant, the atrial sensing was 2.3 +/- 0.7 mV, the atrial pacing threshold was 0.95 +/- 0.15 V (0.5 ms) and the impedance was 760 +/- 80 Ohm. We evaluated the pts during four periods of 3 months duration each. The first period (control) was before pacemaker implantation, while the pts were under antiarrhythmic treatment. During the subsequent two periods, we evaluated the clinical efficacy of IAS pacing to prevent PAF recurrences, in AAT (75 bpm) and AAIR (75-140 bpm) mode, with random selection of the order and after discontinuation of antiarrhythmic treatment. During the fourth period, the same AAIR mode was assessed, but antiarrhythmic drugs were also administered. We compared the arrhythmia free interval among the four periods. The proportion of atrial paced beats in AAIR pacing mode plus antiarrhythmics was significantly higher compared with the drug-free period in AAIR mode (57 +/- 9% and 49 +/- 9% respectively, P=0017) and with AAT pacing mode (44 +/- 10%,(, P<0.001). In AAT mode, the arrhythmia free interval was 24.2 +/- 5.1 days, while it was 26.2 +/- 5.7 days in AAIR mode. These intervals did not differ significantly from the pre-implantation period (24.1 +/- 6.3 days). The arrhythmia free interval in AAIR pacing in combination with antiarrhythmic drug therapy was 38.7 +/- 8.1 days and this was significantly longer than the previous periods (P<0.05). Atrial septal pacing in combination with antiarrhythmic drug therapy reduced the incidence of PAF in pts with prolonged inter-atrial conduction times. Pace mapping of the IAS is an attractive technique to assess the shortest atrial activation time between HRA and distal CS. Whether placement of the atrial lead based on the shortest HRA--distal CS time is the best place in the IAS to prevent PAF still remains to be proven.

  5. Assessment of left atrial volume and function: a comparative study between echocardiography, magnetic resonance imaging and multi slice computed tomography.

    PubMed

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas; Andersen, Mads J; Vejlstrup, Niels; Kelbæk, Henning; Engstrøm, Thomas; Møller, Jacob E; Kofoed, Klaus F

    2012-06-01

    Measurement of left atrial (LA) maximal volume (LA(max)) using two-dimensional transthoracic echocardiography (TTE) provides prognostic information in several cardiac diseases. However, the relationship between LA(max) and LA function is poorly understood and TTE is less well suited for measuring dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir volume) and pump function (left atrial ejection fraction-LAEF) were derived using CMR and MSCT. Left atrial fractional change and left atrial ejection fraction (LAEF) determined with CMR and MSCT were unrelated to LA(max) enlargement by echocardiography (P = NS). There was an overall good agreement between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P < 0.001). Left atrial function assessed with MSCT and CMR as LA fractional change and LAEF is not significantly related to LA(max) measured by TTE. TTE systematically underestimated LA volumes, whereas there are good agreements between MSCT and CMR for volumetric and functional properties.

  6. Randomized trial of atrial arrhythmia monitoring to guide anticoagulation in patients with implanted defibrillator and cardiac resynchronization devices.

    PubMed

    Martin, David T; Bersohn, Malcolm M; Waldo, Albert L; Wathen, Mark S; Choucair, Wassim K; Lip, Gregory Y H; Ip, John; Holcomb, Richard; Akar, Joseph G; Halperin, Jonathan L

    2015-07-07

    Atrial tachyarrhythmias (ATs) detected by implanted devices are often atrial fibrillation or flutter (AF) associated with stroke. We hypothesized that introduction and termination of anticoagulation based upon AT monitoring would reduce both stroke and bleeding. We randomized 2718 patients with dual-chamber and biventricular defibrillators to start and stop anticoagulation based on remote rhythm monitoring vs. usual office-based follow-up with anticoagulation determined by standard clinical criteria. The primary analysis compared the composite endpoint of stroke, systemic embolism, and major bleeding with the two strategies. The trial was stopped after 2 years median follow-up based on futility of finding a difference in primary endpoints between groups. A total of 945 patients (34.8%) developed AT, 264 meeting study anticoagulation criteria. Adjudicated atrial electrograms confirmed AF in 91%; median time to initiate anticoagulation was 3 vs. 54 days in the intervention and control groups, respectively (P < 0.001). Primary events (2.4 vs. 2.3 per 100 patient-years) did not differ between groups (HR 1.06; 95% CI 0.75-1.51; P = 0.732). Major bleeding occurred at 1.6 vs. 1.2 per 100 patient-years (HR 1.39; 95% CI 0.89-2.17; P = 0.145). In patients with AT, thromboembolism rates were 1.0 vs. 1.6 per 100 patient-years (relative risk -35.3%; 95% CI -70.8 to 35.3%; P = 0.251). Although AT burden was associated with thromboembolism, there was no temporal relationship between AT and stroke. In patients with implanted defibrillators, the strategy of early initiation and interruption of anticoagulation based on remotely detected AT did not prevent thromboembolism and bleeding. IMPACT ClinicalTrials.gov identifier: NCT00559988 ( http://clinicaltrials.gov/ct2/show/NCT00559988?term=NCT00559988&rank=1 ). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  7. Catheter ablation of asymptomatic longstanding persistent atrial fibrillation: impact on quality of life, exercise performance, arrhythmia perception, and arrhythmia-free survival.

    PubMed

    Mohanty, Sanghamitra; Santangeli, Pasquale; Mohanty, Prasant; Di Biase, Luigi; Holcomb, Shawna; Trivedi, Chintan; Bai, Rong; Burkhardt, David; Hongo, Richard; Hao, Steven; Beheiry, Salwa; Santoro, Francesco; Forleo, Giovanni; Gallinghouse, Joseph G; Horton, Rodney; Sanchez, Javier E; Bailey, Shane; Hranitzky, Patrick M; Zagrodzky, Jason; Natale, Andrea

    2014-10-01

    Impact of catheter ablation on exercise performance, quality of life (QoL) and symptom perception in asymptomatic longstanding persistent AF (LSP-AF) patients has not been reported yet. Sixty-one consecutive patients (mean age 62 ±13 years, 71% males) with asymptomatic LSP-AF undergoing first catheter ablation were enrolled. Extended pulmonary vein antrum isolation plus ablation of complex fractionated atrial electrograms and nonpulmonary vein triggers was performed in all. QoL survey was taken at baseline and 12-months postablation, using Short Form-36 (SF-36). Information on arrhythmia perception was obtained using a standard questionnaire and corroborating symptoms with documented evidence of arrhythmia. Exercise tests were performed on 38 patients at baseline and 5 months after procedure. Recurrence was assessed using event recorder, cardiology evaluation, electrocardiogram, and 7-day holter monitoring. After 20 ± 5 months follow-up, 36 (57%) patients remained recurrence-free off-AAD. Of the 25 patients experiencing recurrence, 21 (84%) were symptomatic. Compared to baseline, follow-up SF-36 scores improved significantly in many measures. For patients with successful ablation, physical component summary (PCS) and mental component summary (MCS) demonstrated substantial improvement ( 64.2 ± 22.3 to 70.1 ± 18.6 [P = 0.041]; PCS: 62.6 ± 18.4 to 70.0 ± 14.4 [P = 0.032]). Postablation exercise study in recurrence-free patients showed significant reduction in resting and peak heart rate (75 ± 11 vs. 90 ± 17 and 132 ± 20 vs. 154.5 ± 36, respectively, P < 0.001), increase in peak oxygen pulse (13.4 ± 3 vs. 18.9 ± 16 mL/beat, Δ5.5 ± 15, P = 0.001), peak VO2 /kg (19.7 ± 5 to 23.4 ± 13 mL/kg/min [Δ 3.7 ± 10, P = 0.043]), and corresponding MET (5.6 ± 1 to 6.7 ± 4 [Δ1.1 ± 3, P = 0.03]). No improvement was observed in patients with failed procedures. Successful ablation improves exercise performance and QoL in asymptomatic LSP-AF patients. © 2014 Wiley Periodicals, Inc.

  8. Effect of Sex Differences on the Association Between Stroke Risk and Left Atrial Anatomy or Mechanics in Patients With Atrial Fibrillation.

    PubMed

    Yoshida, Kuniko; Obokata, Masaru; Kurosawa, Koji; Sorimachi, Hidemi; Kurabayashi, Masahiko; Negishi, Kazuaki

    2016-10-01

    Embolic stroke in atrial fibrillation is more prevalent in women than in men, yet the basis for this difference remains unclear. This study seeks to elucidate whether there are any sex differences in the relationships between stroke risk (CHADS 2 score, CHA 2 DS 2 -VASc score without a sex category, and estimated stroke rate) and left atrial (LA) anatomy or mechanics in patients with atrial fibrillation. LA emptying fraction and global peak atrial longitudinal strain were assessed in 414 subjects with paroxysmal or persistent atrial fibrillation (156 women and 258 men). Linear regression models with an interaction term were performed to test the effect of sex difference on associations between the embolic risk and LA function or anatomy. Sensitivity analyses were performed in 228 age, heart rate, and rhythm-matched subjects (114 women and men). Women were older and had larger LA volumes and lower LA mechanics than men. Significant negative association between the CHADS 2 score and LA emptying fraction was only demonstrated in women with a significant interaction between sexes. Similar significant interactions were found in global peak atrial longitudinal strain but not in LA volume. These findings were corroborated in the comparisons against CHA 2 DS 2 -VASc score without a sex category and the estimated stroke rate. Sensitivity analyses in the matched subgroup also confirmed the robustness of these sex differences in LA emptying fraction, but less so in global peak atrial longitudinal strain. Significant sex interactions on the association between global LA function and risk stratification schemes exist, which may be a reason for the higher prevalence of embolic stroke in women. © 2016 American Heart Association, Inc.

  9. Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study.

    PubMed

    Martinez-Mateu, Laura; Romero, Lucia; Ferrer-Albero, Ana; Sebastian, Rafael; Rodríguez Matas, José F; Jalife, José; Berenfeld, Omer; Saiz, Javier

    2018-03-01

    Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35-94% of the simulation time, depending on the basket's position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures.

  10. Treatment of Recurrent Nonparoxysmal Atrial Fibrillation Using Focal Impulse and Rotor Mapping (FIRM)-Guided Rotor Ablation: Early Recurrence and Long-Term Outcomes.

    PubMed

    Spitzer, Stefan Georg; Károlyi, László; Rämmler, Carola; Scharfe, Frank; Weinmann, Thomas; Zieschank, Mirko; Langbein, Anke

    2017-01-01

    A patient-tailored ablation approach focused on the elimination of both pulmonary vein triggers as well as substrate drivers may result in favorable outcomes in recurrent persistent AF patients. We evaluated the long-term outcomes of rotor ablation combined with conventional pulmonary vein isolation (PVI) in patients with recurrent nonparoxysmal AF. Fifty-eight consecutive patients underwent FIRM-guided rotor ablation followed by conventional PVI for the treatment of recurrent nonparoxysmal AF. A software algorithm was used to display rotational activity at rotor sites by creating propagation maps from unipolar electrograms recorded using a 64-electrode basket catheter. These rotor sites were targeted for ablation, followed by conventional PVI. All patients had nonparoxysmal AF (83% longstanding persistent) and a previously failed conventional ablation procedure. Stable rotors were identified in all patients (mean of 3.0 ± 1.6 per patient), with 55.2% having right atrial rotors and 96.6% left atrial rotors, respectively. Complications occurred in 5.2% of patients, none related to the FIRM procedure. The median follow-up was 12 months. At 6 and 12 months of follow-up, 73.2% and 76.9% of patients remained free from AF/AT, respectively. Excluding 2 patients who underwent a successful redo ablation procedure/electrical cardioversion, at 12 months of follow-up, 69.2% were free from any AF/AT and 73.1% were free from AF after a single FIRM-guided ablation procedure. A high degree of success was observed in this cohort of primarily longstanding persistent AF patients treated for recurrent AF with FIRM-guided rotor ablation. Prospective randomized controlled trials are needed. © 2016 Wiley Periodicals, Inc.

  11. Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study

    PubMed Central

    Romero, Lucia; Rodríguez Matas, José F.; Berenfeld, Omer; Saiz, Javier

    2018-01-01

    Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35–94% of the simulation time, depending on the basket’s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures. PMID:29505583

  12. Atrial Fibrillation Ablation Guided by a Novel Nonfluoroscopic Navigation System.

    PubMed

    Ballesteros, Gabriel; Ramos, Pablo; Neglia, Renzo; Menéndez, Diego; García-Bolao, Ignacio

    2017-09-01

    Rhythmia is a new nonfluoroscopic navigation system that is able to create high-density electroanatomic maps. The aim of this study was to describe the acute outcomes of atrial fibrillation (AF) ablation guided by this system, to analyze the volume provided by its electroanatomic map, and to describe its ability to locate pulmonary vein (PV) reconnection gaps in redo procedures. This observational study included 62 patients who underwent AF ablation with Rhythmia compared with a retrospective cohort who underwent AF ablation with a conventional nonfluoroscopic navigation system (Ensite Velocity). The number of surface electrograms per map was significantly higher in Rhythmia procedures (12 125 ± 2826 vs 133 ± 21 with Velocity; P < .001), with no significant differences in the total procedure time. The Orion catheter was placed for mapping in 99.5% of PV (95.61% in the control group with a conventional circular mapping catheter; P = .04). There were no significant differences in the percentage of PV isolation between the 2 groups. In redo procedures, an ablation gap could be identified on the activation map in 67% of the reconnected PV (40% in the control group; P = .042). The measured left atrial volume was lower than that calculated by computed tomography (109.3 v 15.2 and 129.9 ± 13.2 mL, respectively; P < .001). There were no significant differences in the number of complications. The Rhythmia system is effective for AF ablation procedures, with procedure times and safety profiles similar to conventional nonfluoroscopic navigation systems. In redo procedures, it appears to be more effective in identifying reconnected PV conduction gaps. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Epinephrine and left atrial and left ventricular diastolic function decrease in normal subjects.

    PubMed

    Fuenmayor, Abdel J; Solórzano, Moisés I; Gómez, Luisangelly

    2016-10-01

    We assessed the effect of epinephrine over left atrial and left ventricular diastolic function in subjects without structural heart disease. Twenty-seven, 34.6±17.2year-old patients without structural heart disease were included. Intravenous epinephrine (50 to 100ng/kg/min) was infused. Left atrial and ventricular functions were evaluated by means of echocardiography before and during the epinephrine infusion. No complications were observed. Significant increases in heart rate and systolic blood pressure were recorded. Both left atrial (minimal and maximal) volumes increased but increase in the minimal volume was more pronounced, and the ejection fraction diminished. Left atrial expansion index decreased and the fraction of left ventricular inflow volume resulting from atrial contraction increased. Two patients displayed abnormal left ventricular diastolic function. During epinephrine infusion, E/A and e' decreased, and isovolumetric relaxation time increased. In this group of young adults without structural heart disease, epinephrine infusion was safe, did not produce any complications, and induced a small but significant decrease in left atrial function and left ventricular diastolic function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Electrograms (ECG, EEG, EMG, EOG).

    PubMed

    Reilly, Richard B; Lee, T Clive

    2010-01-01

    There is a constant need in medicine to obtain objective measurements of physical and cognitive function as the basis for diagnosis and monitoring of health. The body can be considered as a chemical and electrical system supported by a mechanical structure. Measuring and quantifying such electrical activity provides a means for objective examination of heath status. The term electrogram, from the Greek electro meaning electricity and gram meaning write or record, is the broad definition given to the recording of electrical signal from the body. In order that comparisons of electrical activity can be made against normative data, certain methods and procedures have been defined for different electrograms. This paper reviews these methods and procedures for the more typical electrograms associated with some of the major organs in the body, providing a first point of reference for the reader.

  15. II.3. Electrograms (ECG, EEG, EMG, EOG).

    PubMed

    Reilly, Richard B; Lee, T Clive

    2010-01-01

    There is a constant need in medicine to obtain objective measurements of physical and cognitive function as the basis for diagnosis and monitoring of health. The body can be considered as a chemical and electrical system supported by a mechanical structure. Measuring and quantifying such electrical activity provides a means for objective examination of heath status. The term electrogram, from the Greek electro meaning electricity and gram meaning write or record, is the broad definition given to the recording of electrical signal from the body. In order that comparisons of electrical activity can be made against normative data, certain methods and procedures have been defined for different electrograms. This paper reviews these methods and procedures for the more typical electrograms associated with some of the major organs in the body, providing a first point of reference for the reader.

  16. Radiofrequency catheter ablation of atrial fibrillation: Electrical modification suggesting transmurality is faster achieved with remote magnetic catheter in comparison with contact force use.

    PubMed

    Bun, Sok-Sithikun; Ayari, Anis; Latcu, Decebal Gabriel; Errahmouni, Abdelkarim; Saoudi, Nadir

    2017-07-01

    Remote magnetic navigation (RMN) and contact force (CF) sensing catheters are available technologies for radiofrequency (RF) catheter ablation of atrial fibrillation (AF). Our purpose was to compare time to electrogram (EGM) modification suggesting transmural lesions between RMN and CF-guided AF ablation. A total of 1,008 RF applications were analyzed in 21 patients undergoing RMN (n = 11) or CF-guided ablation (n = 10) for paroxysmal AF. All procedures were performed in sinus rhythm during general anesthesia. Time to EGM modification was measured until transmurality criteria were fulfilled: (1) complete disappearance of R if initial QR morphology; (2) diminution > 75% of R if initial QRS morphology; (3) complete disappearance of R' of initial RSR' morphology. Impedance drop as well as force time integral (FTI) were also assessed for each application. Mean CF at the beginning of each RF application in the CF group was 11 ± 2 g and mean FTI per application was 488 ± 163 gs. Time to EGM modification was significantly shorter in the RMN group (4.52 ± 0.1 seconds vs. 5.6 ± 0.09 seconds; P < 0.00001). There was no significant difference between other procedural parameters. Remote magnetic AF ablation is associated with faster EGM modification suggesting transmurality than optimized CF and FTI-guided catheter ablation. © 2017 Wiley Periodicals, Inc.

  17. Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla.

    PubMed

    Vergara, Gaston R; Vijayakumar, Sathya; Kholmovski, Eugene G; Blauer, Joshua J E; Guttman, Mike A; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W; Daccarett, Marcos; McGann, Christopher J; Macleod, Rob S; Marrouche, Nassir F

    2011-02-01

    Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. REAL TIME MRI GUIDED RADIOFREQUENCY ATRIAL ABLATION AND VISUALIZATION OF LESION FORMATION AT 3-TESLA

    PubMed Central

    Vergara, Gaston R.; Vijayakumar, Sathya; Kholmovski, Eugene G.; Blauer, Joshua J.E.; Guttman, Mike A.; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W.; Daccarett, Marcos; McGann, Christopher J.; MacLeod, Rob S.; Marrouche, Nassir F.

    2011-01-01

    Background MRI allows visualization of location and extent of RF ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT-MRI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. Objective To develop of a 3-Tesla RT-MRI based catheter ablation and lesion visualization system. Methods RF energy was delivered to six pigs under RT-MRI guidance. A novel MRI compatible mapping and ablation catheter was used. Under RT-MRI this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bi-polar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2w) HASTE sequence during ablation. Results Real-time visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement (LGE) MRI and macroscopic tissue examination. Conclusion MRI compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT-MRI guidance. It is also feasible to record electrograms during RT imaging. Real-time visualization of lesion as it forms during delivery of RF energy is possible and was demonstrated using T2w HASTE imaging. PMID:21034854

  19. Cardiac cycle-dependent left atrial dynamics: implications for catheter ablation of atrial fibrillation.

    PubMed

    Patel, Amit R; Fatemi, Omid; Norton, Patrick T; West, J Jason; Helms, Adam S; Kramer, Christopher M; Ferguson, John D

    2008-06-01

    Left atrial (LA) volume determines prognosis and response to therapy for atrial fibrillation. Integration of electroanatomic maps with three-dimensional images rendered from computed tomography and magnetic resonance imaging (MRI) is used to facilitate atrial fibrillation ablation. The purpose of this study was to measure LA volume changes and regional motion during the cardiac cycle that might affect the accuracy of image integration and to determine their relationship to standard LA volume measurements. MRI was performed in 30 patients with paroxysmal atrial fibrillation. LA time-volume curves were generated and used to divide LA ejection fraction into pumping ejection fraction and conduit ejection fraction and to determine maximum LA volume (LA(max)) and preatrial contraction volume. LA volume was measured using an MRI angiogram and traditional geometric models from echocardiography (area-length model and ellipsoid model). In-plane displacement of the pulmonary veins, anterior left atrium, mitral annulus, and LA appendage was measured. LA(max) was 107 +/- 36 mL and occurred at 42% +/- 5% of the R-R interval. Preatrial contraction volume was 86 +/- 34 mL and occurred at 81% +/- 4% of the R-R interval. LA ejection fraction was 45% +/- 10%, and pumping ejection fraction was 31% +/- 10%. LA volume measurements made from MRI angiogram, area-length model, and ellipsoid model underestimated LA(max) by 21 +/- 25 mL, 16 +/- 26 mL, and 35 +/- 22 mL, respectively. Anterior LA, mitral annulus, and LA appendage were significantly displaced during the cardiac cycle (8.8 +/- 2.0 mm, 13.2 +/- 3.8 mm, and 10.2 +/- 3.4 mm, respectively); the pulmonary veins were not displaced. LA volume changes significantly during the cardiac cycle, and substantial regional variation in LA motion exists. Standard measurements of LA volume significantly underestimate LA(max) compared to the gold standard measure of three-dimensional volumetrics.

  20. Echocardiographic Parameters and Survival in Chagas Heart Disease with Severe Systolic Dysfunction

    PubMed Central

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-01-01

    Background Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. Objective To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Methods Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. Results In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m2 were associated with a significant increase in mortality (log rank p < 0.0001). Conclusion The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction. PMID:24553982

  1. Echocardiographic parameters and survival in Chagas heart disease with severe systolic dysfunction.

    PubMed

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-03-01

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m2 were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction.

  2. Early Efficacy Analysis of Biatrial Ablation versus Left and Simplified Right Atrial Ablation for Atrial Fibrillation Treatment in Patients with Rheumatic Heart Disease.

    PubMed

    Liu, Hong; Chen, Lin; Xiao, Yingbin; Ma, Ruiyan; Hao, Jia; Chen, Baicheng; Qin, Chuan; Cheng, Wei

    2015-08-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia. About 60% of patients with rheumatic heart disease have persistent AF. A total of 197 patients underwent valve replacement concomitant bipolar radiofrequency ablation (BRFA). Patients were divided into the biatrial ablation group and the simplified right atrial ablation group. In biatrial ablation group, the patients underwent a complete left and right atrial ablation. In simplified right atrial ablation group, the patients underwent a complete left atrial ablation and a simplified right atrial ablation. The conversion of sinus rhythm (SR) was high in both groups during the follow-up period. In the simplified right atrial ablation group, SR conversion rate was 88.29% at discharge. At six months and 12 months after surgery, 87.39% of patients and 86.49% of patients were in SR free of antiarrhythmic drugs, respectively. While in the biatrial ablation group, SA conversion rate was 89.53% at discharge. Percentage of patients in SR free of antiarrhythmic drugs was 88.37% and 88.37% at six months and 12 months after surgery, respectively. Echocardiography showed left atrial diameter decreased significantly after the surgery in the two groups. The ejection fraction and fractional shortening were improved significantly, without significant differences between the two groups. The results suggest that the concomitant left atrial and simplified right atrial BRFA for AF in patients undergoing valve replacement can achieve similar early efficiency as biatrial ablation. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  3. Electrical and Structural Substrate of Arrhythmogenic Right Ventricular Cardiomyopathy Determined Using Noninvasive Electrocardiographic Imaging and Late Gadolinium Magnetic Resonance Imaging.

    PubMed

    Andrews, Christopher M; Srinivasan, Neil T; Rosmini, Stefania; Bulluck, Heerajnarain; Orini, Michele; Jenkins, Sharon; Pantazis, Antonis; McKenna, William J; Moon, James C; Lambiase, Pier D; Rudy, Yoram

    2017-07-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a significant cause of sudden cardiac death in the young. Improved noninvasive assessment of ARVC and better understanding of the disease substrate are important for improving patient outcomes. We studied 20 genotyped ARVC patients with a broad spectrum of disease using electrocardiographic imaging (a method for noninvasive cardiac electrophysiology mapping) and advanced late gadolinium enhancement cardiac magnetic resonance scar imaging. Compared with 20 healthy controls, ARVC patients had longer ventricular activation duration (median, 52 versus 42 ms; P =0.007) and prolonged mean epicardial activation-recovery intervals (a surrogate for local action potential duration; median, 275 versus 241 ms; P =0.014). In these patients, we observed abnormal and varied epicardial activation breakthrough locations and regions of nonuniform conduction and fractionated electrograms. Nonuniform conduction and fractionated electrograms were present in the early concealed phase of ARVC. Electrophysiological abnormalities colocalized with late gadolinium enhancement scar, indicating a relationship with structural disease. Premature ventricular contractions were common in ARVC patients with variable initiation sites in both ventricles. Premature ventricular contraction rate increased with exercise, and within anatomic segments, it correlated with prolonged repolarization, electric markers of scar, and late gadolinium enhancement (all P <0.001). Electrocardiographic imaging reveals electrophysiological substrate properties that differ in ARVC patients compared with healthy controls. A novel mechanistic finding is the presence of repolarization abnormalities in regions where ventricular ectopy originates. The results suggest a potential role for electrocardiographic imaging and late gadolinium enhancement in early diagnosis and noninvasive follow-up of ARVC patients. © 2017 American Heart Association, Inc.

  4. Spectral analysis of epicardial 60-lead electrograms in dogs with 4-week-old myocardial infarction.

    PubMed

    Hosoya, Y; Ikeda, K; Komatsu, T; Yamaki, M; Kubota, I

    2001-01-01

    There were few studies on the spectral analysis of multiple-lead epicardial electrograms in chronic myocardial infarction. Spectral analysis of multi-lead epicardial electrograms was performed in 6 sham-operated dogs (N group) and 8 dogs with 4-week-old myocardial infarction (MI group). Four weeks after the ligation of left anterior descending coronary artery, fast Fourier transform was performed on 60-lead epicardial electrograms, and then inverse transform was performed on 5 frequency ranges from 0 to 250 Hz. From the QRS onset to QRS offset, the time integration of unsigned value of reconstructed waveform was calculated and displayed as AQRS maps. On 0-25 Hz AQRS map, there was no significant difference between the 2 groups. In the frequency ranges of 25-250 Hz, MI group had significantly smaller AQRS values than N group solely in the infarct zone. It was shown that high frequency potentials (25-250 Hz) within QRS complex were reduced in the infarct zone.

  5. Evaluation of atrial electromechanical delay and left atrial mechanical function in patients with obstructive sleep apnea : Cardiac involvement in patients with OSA.

    PubMed

    Karabag, Turgut; Aydin, Mustafa; Altin, Remzi; Dogan, Sait M; Cil, Cem; Buyukuysal, Cagatay; Sayin, Muhammet R

    2012-07-01

    The aim of this study was to evaluate atrial electromechanical delay measured by tissue Doppler imaging and left atrial mechanical function in patients with obstructive sleep apnea (OSA). Fourty-seven moderate-to-severe OSA patients who were newly diagnosed by polysomnography (Apnea-hypopnea index ≥ 15 events/h, 32 males, mean age 49.4 ± 11.5) and 30 patients who had no OSA in polysomnography (Apnea-hypopnea index < 5 events/h, 21 males, mean age 45.4 ± 9.1) were included in the study. Using tissue Doppler, diastolic functions, atrial electromechanical coupling were measured from the lateral mitral, septal, and tricuspid annulus. Inter, intra, and left atrial electromechanical delay were calculated (lateral-tricuspid, septum-tricuspid, lateral-septal). Left atrial volumes (maximal, minimal, and presystolic) were measured by the method of discs in the apical four-chamber view and were indexed to body surface area. Mechanical function parameters of the left atrium were also calculated. Interatrial, intraatrial, and left atrial electromechanical delays were significantly higher in the OSA group compared to the control group. Passive emptying fraction was significantly decreased, volume at the beginning of atrial systole and active emptying volume were significantly increased in OSA patients compared to the controls. The apnea-hypopnea index was significantly associated with interatrial and intraatrial electromechanical delay, passive emptying fraction, and conduit volume. Electromechanical delay was markedly prolonged and left atrial electromechanical function was impaired in untreated OSA patients. These impairments worsen with increasing severity of OSA.

  6. Inappropriate ICD discharges due to "triple counting" during normal sinus rhythm.

    PubMed

    Khan, Ejaz; Voudouris, Apostolos; Shorofsky, Stephen R; Peters, Robert W

    2006-11-01

    To describe the clinical course of a patient with multiple ICD shocks in the setting of advanced renal failure and hyperkalemia. The patient was brought to the Electrophysiology Laboratory where the ICD was interrogated. The patient was found to be hyperkalemic (serum potassium 7.6 mg/dl). Analysis of stored intracardiac electrograms from the ICD revealed "triple counting" (twice during his QRS complex and once during the T wave) and multiple inappropriate shocks. Correction of his electrolyte abnormality normalized his electrogram and no further ICD activations were observed. Electrolyte abnormalities can distort the intracardiac electrogram in patients with ICD's and these changes can lead to multiple inappropriate shocks.

  7. Assessment of left atrial mechanical functions and atrial electromechanical delay in Juvenile idiopathic arthritis by tissue Doppler echocardiography.

    PubMed

    El Eraky, Azza Z; Handoka, Nesrin M; Ghaly, Mona Sayed; Nasef, Samah Ismail; Eldahshan, Nahed A; Ibrahim, Ahmed M; Shalaby, Sherein

    2016-11-24

    Juvenile idiopathic arthritis (JIA) is a systemic chronic inflammatory disease. Studies using tissue Doppler imaging (TDI) for the evaluation of cardiac functions of children with JIA are limited. Thus, this study was conducted to evaluate Left ventricular function, left atrial mechanical functions and atrial electromechanical delay in JIA. This study was carried out as a across sectional study. A total of 34 patients with active JIA and 34 controls were included. Atrial electromechanical delay and left atrial (LA) mechanical functions in addition to systolic and diastolic left ventricular (LV) functions were measured by using conventional echocardiography and TDI. Assessment of disease activity was done using Juvenile arthritis disease activity score (JADAS-27). JIA patients had abnormal atrial electromechanical coupling as established from prolonged lateral mitral annulus (PA lateral), septal mitral annulus (PA septum), inter-atrial and intra-atrial electromechanical delays compared with healthy controls. Left ventricular filling abnormalities were found characterized by a reduced E/A ratio (1.07 ± 0.56 vs. 1.48 ± 0.16, p = 0.01). E/Em was significantly higher in patients with JIA (7.58 ± 1.79 vs. 4.74 ± 1.45, p = 0.003) denoting impaired diastolic function. Left atrial mechanical functions assessment showed significantly decreased LA passive emptying fraction, increased LA active emptying fraction and LA total emptying volume in JIA patients (p = 0.01, p = 0.01, p = 0.03 respectively). Atrial electromechanical coupling intervals, and LA mechanical functions were impaired which can be considered as an early form of subclinical cardiac involvement in JIA patients. Significant diastolic functional abnormalities exist in JIA.

  8. Cardiac function adaptations in hibernating grizzly bears (Ursus arctos horribilis).

    PubMed

    Nelson, O Lynne; Robbins, Charles T

    2010-03-01

    Research on the cardiovascular physiology of hibernating mammals may provide insight into evolutionary adaptations; however, anesthesia used to handle wild animals may affect the cardiovascular parameters of interest. To overcome these potential biases, we investigated the functional cardiac phenotype of the hibernating grizzly bear (Ursus arctos horribilis) during the active, transitional and hibernating phases over a 4 year period in conscious rather than anesthetized bears. The bears were captive born and serially studied from the age of 5 months to 4 years. Heart rate was significantly different from active (82.6 +/- 7.7 beats/min) to hibernating states (17.8 +/- 2.8 beats/min). There was no difference from the active to the hibernating state in diastolic and stroke volume parameters or in left atrial area. Left ventricular volume:mass was significantly increased during hibernation indicating decreased ventricular mass. Ejection fraction of the left ventricle was not different between active and hibernating states. In contrast, total left atrial emptying fraction was significantly reduced during hibernation (17.8 +/- 2.8%) as compared to the active state (40.8 +/- 1.9%). Reduced atrial chamber function was also supported by reduced atrial contraction blood flow velocities and atrial contraction ejection fraction during hibernation; 7.1 +/- 2.8% as compared to 20.7 +/- 3% during the active state. Changes in the diastolic cardiac filling cycle, especially atrial chamber contribution to ventricular filling, appear to be the most prominent macroscopic functional change during hibernation. Thus, we propose that these changes in atrial chamber function constitute a major adaptation during hibernation which allows the myocardium to conserve energy, avoid chamber dilation and remain healthy during a period of extremely low heart rates. These findings will aid in rational approaches to identifying underlying molecular mechanisms.

  9. HIS bundle electrogram in rheumatic mitral valve disease with special reference to Bachmann's bundle block in P mitrale.

    PubMed

    Lee, Y S; Lien, W P

    1975-08-01

    HBEs were recorded from either the right or left ventricle or simultaneously from both in 26 patients with chronic rheumatic mitral stenosis alone or in association with other mild valvular lesions during the diagnostic cardiac catheterization. Eleven of the patients had auricular fibrillation. Of the remaining 15 patients with sinus mechanism and P mitrale in the surface electrocardiogram, 12 were noted to have H potential preceded the termination of P wave and gave P2H interval of negative value- so-called "Bachmann's bundle block". Among these, double atrial activities (A and A' waves) could be identified on the HBE recorded from the left ventricular endocardial surface with catheter electrodes positioned at the subarotic region in 7 patients studied. Interatrial conduction time (P1A' interval) measured in these patients was prolonged in all and ranged from 47 to 82 with an average of 66 msec. Prolongation of intraatrial (or internodal) conduction time was noted in only one patient who also had first degree A-V block and prolonged A-H interval. There was no correlation of either P1P2 or P2H interval to the degree of left atrial enlargement. The P1P2 or P2H interval also had no correlation with hemodynamic parameters. In patients with auricular fibrillation, all impulses unable to conduct to the ventricle were blocked proximal to the His bundle and concealed conduction was not observed distal to it.

  10. Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter.

    PubMed

    Gould, Paul A; Booth, Cameron; Dauber, Kieran; Ng, Kevin; Claughton, Andrew; Kaye, Gerald C

    2016-12-01

    This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort. Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF. CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this. © 2016 Wiley Periodicals, Inc.

  11. Initial experience of a novel mapping system combined with remote magnetic navigation in the catheter ablation of atrial fibrillation.

    PubMed

    Lin, Changjian; Pehrson, Steen; Jacobsen, Peter Karl; Chen, Xu

    2017-12-01

    There have been advancements of sophisticated mapping systems used for ablation procedures over the last decade. Utilization of these novel mapping systems in combination with remote magnetic navigation (RMN) needs to be established. We investigated the new EnSite Precision mapping system (St. Jude Medical, Inc., St. Paul, MN, USA), which collects magnetic data for checking navigation field stability and is built on an open platform, allowing physicians to choose diagnostic and ablation catheters. We address its compatibility with RMN. To assess the clinical utility of a novel 3D mapping system (EnSite Precision mapping system) combined with RMN (Niobe ES, Stereotaxis, Inc., St. Louis, MO, USA) for atrial fibrillation (AF) ablation. In this prospective nonrandomized study, two groups of patients were treated in our center for drug refractory AF. Patients were consecutively enrolled in each group. Group A (n = 35, 14 persistent AF [PsAF]) was treated using the novel 3D mapping system combined with RMN. Group B (n = 38, 16 PsAF) was treated using Carto ® 3 (Biosense Webster, Inc., Diamond Bar, CA, USA) combined with RMN. In Group A, the left atrium (LA) was mapped with a circular magnetic catheter manually and was then replaced by a RMN ablation catheter. At the end of the procedures in Group A, the circular catheter was used for confirming field stability. In Group B, an ablation catheter was controlled by RMN to perform both LA mapping and ablation. All patients underwent pulmonary vein antrum isolation. Additional complex fractionated atrial electrograms (CFAEs) ablation was performed for PsAF. Procedural, ablation, and fluoroscopy times were recorded and complications were assessed. Electrophysiological end points were achieved in all patients. Using the novel mapping system, LA mapping time was fast (308 ± 60 seconds) with detailed anatomy points (178,831 ± 70,897) collected and magnetic points throughout LA. At the end of the procedures in Group A, the LA model was confirmed to be stable and its location was within the distance threshold (1 mm). Procedure time (117.9 ± 29.6 minutes vs. 119.2 ± 29.7 minutes, P = 0.89), fluoroscopy time (6.1 ± 2.4 minutes vs. 4.8 ± 2.2 minutes, P = 0.07), and ablation time (28.0 ± 12.9 minutes vs. 27.9 ± 15.8 minutes, P = 0.98) were similar in Group A versus Group B, respectively. No complications occurred in either group. LA mapped by the novel system is stable and reliable. Combined with RMN, it could be effectively used for AF ablation without impacting overall procedural times. © 2017 Wiley Periodicals, Inc.

  12. Unipolar Endocardial Voltage Mapping in the Right Ventricle: Optimal Cutoff Values Correcting for Computed Tomography-Derived Epicardial Fat Thickness and Their Clinical Value for Substrate Delineation.

    PubMed

    Venlet, Jeroen; Piers, Sebastiaan R D; Kapel, Gijsbert F L; de Riva, Marta; Pauli, Philippe F G; van der Geest, Rob J; Zeppenfeld, Katja

    2017-08-01

    Low endocardial unipolar voltage (UV) at sites with normal bipolar voltage (BV) may indicate epicardial scar. Currently applied UV cutoff values are based on studies that lacked epicardial fat information. This study aimed to define endocardial UV cutoff values using computed tomography-derived fat information and to analyze their clinical value for right ventricular substrate delineation. Thirty-three patients (50±14 years; 79% men) underwent combined endocardial-epicardial right ventricular electroanatomical mapping and ablation of right ventricular scar-related ventricular tachycardia with computed tomographic image integration, including computed tomography-derived fat thickness. Of 6889 endocardial-epicardial mapping point pairs, 547 (8%) pairs with distance <10 mm and fat thickness <1.0 mm were analyzed for voltage and abnormal (fragmented/late potential) electrogram characteristics. At sites with endocardial BV >1.50 mV, the optimal endocardial UV cutoff for identification of epicardial BV <1.50 mV was 3.9 mV (area under the curve, 0.75; sensitivity, 60%; specificity, 79%) and cutoff for identification of abnormal epicardial electrogram was 3.7 mV (area under the curve, 0.88; sensitivity, 100%; specificity, 67%). The majority of abnormal electrograms (130 of 151) were associated with transmural scar. Eighty-six percent of abnormal epicardial electrograms had corresponding endocardial sites with BV <1.50 mV, and the remaining could be identified by corresponding low endocardial UV <3.7 mV. For identification of epicardial right ventricular scar, an endocardial UV cutoff value of 3.9 mV is more accurate than previously reported cutoff values. Although the majority of epicardial abnormal electrograms are associated with transmural scar with low endocardial BV, the additional use of endocardial UV at normal BV sites improves the diagnostic accuracy resulting in identification of all epicardial abnormal electrograms at sites with <1.0 mm fat. © 2017 American Heart Association, Inc.

  13. Two-year clinical follow-up after pulmonary vein isolation using high-intensity focused ultrasound (HIFU) and an esophageal temperature-guided safety algorithm.

    PubMed

    Neven, Kars; Metzner, Andreas; Schmidt, Boris; Ouyang, Feifan; Kuck, Karl-Heinz

    2012-03-01

    High-intensity frequency ultrasound (HIFU) can achieve pulmonary vein isolation (PVI), but severe complications have happened. An esophageal temperature (ET)-guided safety algorithm was implemented. We investigated medium-term outcome. After left atrial access, HIFU was applied until complete PVI. The safety algorithm was as follows: ≤3 complete ablations per pulmonary vein, early abortion when ET ≥40.0°C, use of Power Modulation at ET >39.0°C or when after 20 to 30 seconds no change in PV electrograms: to reduce the ablation temperature in the surrounding tissue, acoustic power is switched on and off with a frequency of 1 Hz; in all first ablations, use of Power Modulation after 50% of programmed time. Touch-up radiofrequency ablation when PVI failed. Follow-up included interviews and Holter electrocardiograms. Recurrence was defined as atrial fibrillation (AF) >30 seconds without a blanking period. A total of 28 symptomatic patients (18 males, age 63 years), with paroxysmal AF (n = 19) and persistent AF (n = 9) were included. After a median follow-up of 738 days, 22 of the 28 patients (79%) were free of AF without antiarrhythmic drugs. After 1 repeat procedure with radiofrequency ablation, 5 patients remained free of AF. The complications were as follows: 1 lethal atrial-to-esophageal fistula at day 31, 1 pericardial effusion at day 48, 1 unexplained death at day 49, and 2 persistent phrenic nerve palsies with full recovery within 12 months. Two-year follow-up after PVI using HIFU and an ET-guided safety algorithm shows success rates similar to those of radiofrequency-based procedures but with higher complication rates. Importantly, the ET-guided safety algorithm failed to prevent severe complications. HIFU does not meet safety standards required for the treatment of AF, and this led to a halt of its clinical use. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  14. High-voltage zones within the pulmonary vein antra: Major determinants of acute pulmonary vein reconnections after atrial fibrillation ablation.

    PubMed

    Nagashima, Koichi; Watanabe, Ichiro; Okumura, Yasuo; Iso, Kazuki; Takahashi, Keiko; Watanabe, Ryuta; Arai, Masaru; Kurokawa, Sayaka; Nakai, Toshiko; Ohkubo, Kimie; Yoda, Shunichi; Hirayama, Atsushi

    2017-08-01

    Recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) is mainly due to PV reconnections. Patient-specific tissue characteristics that may contribute remain unidentified. This study aimed to assess the relationship between the bipolar electrogram voltage amplitudes recorded from the PV-left atrial (LA) junction and acute PV reconnection sites. Three-dimensional LA voltage maps created before an extensive encircling PVI in 47 AF patients (31 men; mean age 62 ± 11 years) were examined for an association between the EGM voltage amplitude recorded from the PV-LA junction and acute post-PVI PV reconnections (spontaneous PV reconnections and/or ATP-provoked dormant PV conduction). Acute PV reconnections were observed in 17 patients (36%) and in 24 (3%) of the 748 PV segments (16 segments per patient) and were associated with relatively high bipolar voltage amplitudes (3.26 ± 0.85 vs. 1.79 ± 1.15 mV, p < 0.0001) and a relatively low mean force-time integral (FTI) (428 ± 56 vs. 473 ± 76 gs, p = 0.0039) as well as FTI/PV-LA bipolar voltage (137 [106, 166] vs. 295 [193, 498] gs/mV, p < 0.0001). An analysis of the receiver operating characteristic curves revealed a high prognostic performance of the LA bipolar voltage and FTI/PV-LA bipolar voltage for acute PV reconnections (areas under the curve: 0.86 and 0.89, respectively); the best cutoff values were >2.12 mV and ≤183 gs/mV, respectively. The PV-LA voltage on the PV-encircling ablation line and FTI/PV-LA voltage were related to the acute post-PVI PV reconnections. A more durable ablation strategy is warranted for high-voltage zones.

  15. Isthmus sites identified by Ripple Mapping are usually anatomically stable: A novel method to guide atrial substrate ablation?

    PubMed

    Luther, Vishal; Qureshi, Norman; Lim, Phang Boon; Koa-Wing, Michael; Jamil-Copley, Shahnaz; Ng, Fu Siong; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa; Linton, Nick

    2018-03-01

    Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P  =  0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach. © 2018 Wiley Periodicals, Inc.

  16. Detection of atrial electromechanical dysfunction in obesity.

    PubMed

    Erdem, Fatma Hizal; Ozturk, Serkan; Baltaci, Davut; Donmez, Ibraham; Alçelik, Aytekin; Ayhan, Selim; Yaz, Mehmet

    2015-12-01

    Obesity is associated with atrial fibrillation and is known as an independent risk factor. The aim of our study was to investigate if there was any association between the body mass index and atrial electromechanical intervals in obese and non-obese patients. Seventy patients were enrolled in the study. Body mass index (BMI), functional capacity, and fasting blood sugar were evaluated; then, these patients were divided into two groups, patients who had a BMI ≥ 30 were known as obese (35 patients) and those who had a BMI < 30 were known as non-obese patients. All patients were evaluated by transthoracic echocardiography. LA volumes were measured by the discs method in the apical four-chamber view. LA active and passive emptying volumes and fraction were calculated. Using TDI, atrial electromechanical coupling (PA) was measured from the lateral mitral annulus (PA lateral), septal mitral annulus (PA septum), and right ventricular tricuspid annulus (PA tricuspid). LA diameter was significantly higher in obese patients (P = 0.021). LA passive emptying volume and fraction were significantly decreased in obese patients (P = 0.038 and P = 0.011). LA active emptying volume and fraction were significantly increased in obese patients (P = 0.001 and P = 0.001). Left intraatrial and interatrial electromechanical delay were significantly higher in obese patients (18.9 ± 3.8 vs 11.9 ± 2.0, P < 0.001 and 29.5 ± 4.1 vs 17.9 ± 2.5, P < 0.001). Also interatrial electromechanical delay correlated positively with BMI. This study revealed that delayed atrial electromechanical interval and impaired LA mechanical functions were related to BMI in obese-patients. These findings may be an early sign of subclinical atrial dysfunction and arrhythmias in obese patients.

  17. The Electrophysiologic Effects of Acute Mitral Regurgitation in a Canine Model.

    PubMed

    Lawrance, Christopher P; Henn, Matthew C; Miller, Jacob R; Kopek, Michael A; Zhang, Andrew J; Schuessler, Richard B; Damiano, Ralph J

    2017-04-01

    Atrial fibrillation (AF) occurs in 30% of patients with mitral regurgitation referred for surgical intervention. However, the underlying mechanisms in this population are poorly understood. This study examined the effects of acute left atrial volume overload on atrial electrophysiology and the inducibility of AF. Ten canines underwent insertion of an atrioventricular shunt between the left ventricle and left atrium. Shunt and aortic flows were calculated, and the shunt was titrated to a shunt fraction to 40% to 50% of cardiac output. An epicardial plaque with 250 bipolar electrodes was used to determine activation and refractory periods. Biatrial pressures and volumes, conduction times, and atrial fibrillation inducibility were recorded. Data were collected at baseline and 20 minutes after shunt opening and closure. Mean shunt flow was 1.3 ± 0.5 L/min with a shunt fraction of 43% ± 6% simulating moderate to severe mitral regurgitation. Compared with baseline, left atrial volumes and maximum pressures increased by 27% and 29%, respectively, after shunt opening. Biatrial effective refractory periods did not change significantly after shunt opening or closure. Conduction times increased by 9% with shunt opening and returned to baseline after closure. AF duration or inducibility did not change with shunt opening. This canine model of mitral regurgitation demonstrated that acute left atrial volume overload did not increase the inducibility of atrial arrhythmias in contrast with experimental and clinical findings of chronic left atrial volume overload. This suggests that the substrates for AF in patients with mitral regurgitation are a result of chronic remodeling. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Benefits of Permanent His Bundle Pacing Combined With Atrioventricular Node Ablation in Atrial Fibrillation Patients With Heart Failure With Both Preserved and Reduced Left Ventricular Ejection Fraction.

    PubMed

    Huang, Weijian; Su, Lan; Wu, Shengjie; Xu, Lei; Xiao, Fangyi; Zhou, Xiaohong; Ellenbogen, Kenneth A

    2017-04-01

    Clinical benefits from His bundle pacing (HBP) in heart failure patients with preserved and reduced left ventricular ejection fraction are still inconclusive. This study evaluated clinical outcomes of permanent HBP in atrial fibrillation patients with narrow QRS who underwent atrioventricular node ablation for heart failure symptoms despite rate control by medication. The study enrolled 52 consecutive heart failure patients who underwent attempted atrioventricular node ablation and HBP for symptomatic atrial fibrillation. Echocardiographic left ventricular ejection fraction and left ventricular end-diastolic dimension, New York Heart Association classification and use of diuretics for heart failure were assessed during follow-up visits after permanent HBP. Of 52 patients, 42 patients (80.8%) received permanent HBP and atrioventricular node ablation with a median 20-month follow-up. There was no significant change between native and paced QRS duration (107.1±25.8 versus 105.3±23.9 milliseconds, P =0.07). Left ventricular end-diastolic dimension decreased from the baseline ( P <0.001), and left ventricular ejection fraction increased from baseline ( P <0.001) in patients with a greater improvement in heart failure with reduced ejection fraction patients (N=20) than in heart failure with preserved ejection fraction patients (N=22). New York Heart Association classification improved from a baseline 2.9±0.6 to 1.4±0.4 after HBP in heart failure with reduced ejection fraction patients and from a baseline 2.7±0.6 to 1.4±0.5 after HBP in heart failure with preserved ejection fraction patients. After 1 year of HBP, the numbers of patients who used diuretics for heart failure decreased significantly ( P <0.001) when compared to the baseline diuretics use. Permanent HBP post-atrioventricular node ablation significantly improved echocardiographic measurements and New York Heart Association classification and reduced diuretics use for heart failure management in atrial fibrillation patients with narrow QRS who suffered from heart failure with preserved or reduced ejection fraction. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  19. Prolongation of atrio-ventricular node conduction in a rabbit model of ischaemic cardiomyopathy: Role of fibrosis and connexin remodelling.

    PubMed

    Nisbet, Ashley M; Camelliti, Patrizia; Walker, Nicola L; Burton, Francis L; Cobbe, Stuart M; Kohl, Peter; Smith, Godfrey L

    2016-05-01

    Conduction abnormalities are frequently associated with cardiac disease, though the mechanisms underlying the commonly associated increases in PQ interval are not known. This study uses a chronic left ventricular (LV) apex myocardial infarction (MI) model in the rabbit to create significant left ventricular dysfunction (LVD) 8weeks post-MI. In vivo studies established that the PQ interval increases by approximately 7ms (10%) with no significant change in average heart rate. Optical mapping of isolated Langendorff perfused rabbit hearts recapitulated this result: time to earliest activation of the LV was increased by 14ms (16%) in the LVD group. Intra-atrial and LV transmural conduction times were not altered in the LVD group. Isolated AVN preparations from the LVD group demonstrated a significantly longer conduction time (by approximately 20ms) between atrial and His electrograms than sham controls across a range of pacing cycle lengths. This difference was accompanied by increased effective refractory period and Wenckebach cycle length, suggesting significantly altered AVN electrophysiology post-MI. The AVN origin of abnormality was further highlighted by optical mapping of the isolated AVN. Immunohistochemistry of AVN preparations revealed increased fibrosis and gap junction protein (connexin43 and 40) remodelling in the AVN of LVD animals compared to sham. A significant increase in myocyte-non-myocyte connexin co-localization was also observed after LVD. These changes may increase the electrotonic load experienced by AVN muscle cells and contribute to slowed conduction velocity within the AVN. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Independent mapping methods reveal rotational activation near pulmonary veins where atrial fibrillation terminates before pulmonary vein isolation.

    PubMed

    Navara, Rachita; Leef, George; Shenasa, Fatemah; Kowalewski, Christopher; Rogers, Albert J; Meckler, Gabriela; Zaman, Junaid A B; Baykaner, Tina; Park, Shirley; Turakhia, Mintu P; Zei, Paul; Viswanathan, Mohan; Wang, Paul J; Narayan, Sanjiv M

    2018-01-29

    To investigate mechanisms by which atrial fibrillation (AF) may terminate during ablation near the pulmonary veins before the veins are isolated (PVI). It remains unstudied how AF may terminate during ablation before PVs are isolated, or how patients with PV reconnection can be arrhythmia-free. We studied patients in whom PV antral ablation terminated AF before PVI, using two independent mapping methods. We studied patients with AF referred for ablation, in whom biatrial contact basket electrograms were studied by both an activation/phase mapping method and by a second validated mapping method reported not to create false rotational activity. In 22 patients (age 60.1 ± 10.4, 36% persistent AF), ablation at sites near the PVs terminated AF (77% to sinus rhythm) prior to PVI. AF propagation revealed rotational (n  =  20) and focal (n  =  2) patterns at sites of termination by mapping method 1 and method 2. Both methods showed organized sites that were spatially concordant (P < 0.001) with similar stability (P < 0.001). Vagal slowing was not observed at sites of AF termination. PV antral regions where ablation terminated AF before PVI exhibited rotational and focal activation by two independent mapping methods. These data provide an alternative mechanism for the success of PVI, and may explain AF termination before PVI or lack of arrhythmias despite PV reconnection. Mapping such sites may enable targeted PV lesion sets and improved freedom from AF. © 2018 Wiley Periodicals, Inc.

  1. Sleep disordered breathing in cardiac surgery patients: The NU-SLEEP trial.

    PubMed

    Sezai, Akira; Akahoshi, Toshiki; Osaka, Shunji; Yaoita, Hiroko; Arimoto, Munehito; Hata, Hiroaki; Tanaka, Masashi; Sekino, Hisakuni; Akashiba, Tsuneto

    2017-01-15

    Sleep disordered breathing (SDB) is associated with lifestyle-related diseases and its treatment influence the prognosis of cardiac disease, but little investigation of SDB has been conducted in cardiac surgery patients. A prospective study was performed in 1005 patients undergoing cardiac surgery. The primary endpoint was the severity of SDB determined from the apnea/hypopnea index. The secondary endpoints were patient background factors, cardiovascular risk factors, ejection fraction, atrial and brain natriuretic peptides, oxidative stress and inflammatory markers, and postoperative atrial fibrillation. While 227 patients (22.6%) did not have SDB, there were 361 patients (35.9%) with mild SDB, 260 patients (25.9%) with moderate SDB, and 157 patients (15.6%) with severe SDB. Patients with severe SDB had a lower ejection fraction and higher levels of atrial and brain natriuretic peptides than the other groups. Postoperative atrial fibrillation occurred in 28 patients without SDB (13.6%), 43 patients with mild SDB (13.5%), 74 patients with moderate SDB (31.9%), and 73 patients with severe SDB (52.5%), being significantly more frequent in the severe group than the other groups. SDB was frequent in cardiac surgery patients. Activation of the renin-angiotensin-aldosterone system, postoperative atrial fibrillation atrial, and cardiac dysfunction were associated with severe SDB. Markers of inflammation and oxidative stress also increased as SDB became more severe. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Dronedarone for the treatment of atrial fibrillation and atrial flutter: approval and efficacy.

    PubMed

    Wolbrette, Deborah; Gonzalez, Mario; Samii, Soraya; Banchs, Javier; Penny-Peterson, Erica; Naccarelli, Gerald

    2010-08-09

    Dronedarone, a new Class III antiarrhythmic agent, has now been approved by the US Food and Drug Administration for use in patients with atrial fibrillation or atrial flutter. Approval came in March 2009 due to the positive results of the ATHENA trial showing significant reductions in all-cause mortality and cardiovascular hospitalization with dronedarone use. A post hoc analysis of the ATHENA data also suggested a decrease in stroke risk with this agent. However, due to safety concerns in the heart failure population in the earlier ANDROMEDA trial, dronedarone is not recommended for patients with an ejection fraction <35% and recent decompensated heart failure. Dronedarone is an amiodarone analog with multichannel blocking electrophysiologic properties similar to those of amiodarone, but several structural differences. Dronedarone's lack of the iodine moiety reduces its potential for thyroid and pulmonary toxicity. Preliminary data from the DIONYSOS trial, and an indirect meta-analysis comparing amiodarone with dronedarone, showed amiodarone to be more effective in maintaining sinus rhythm, while dronedarone was associated with fewer adverse effects resulting in early termination of the drug. Dronedarone is the first antiarrhythmic drug for the treatment of atrial fibrillation and atrial flutter shown to reduce cardiovascular hospitalizations. In patients with structural heart disease who have an ejection fraction >35% and no recent decompensated heart failure, dronedarone should be considered earlier than amiodarone in the treatment algorithm.

  3. Modified Maze Procedure for Atrial Fibrillation as an Adjunct to Elective Cardiac Surgery: Predictors of Mid-Term Recurrence and Echocardiographic Follow-Up

    PubMed Central

    Alamanni, Francesco; Veglia, Fabrizio; Galli, Claudia; Parolari, Alessandro; Zanobini, Marco

    2015-01-01

    The radiofrequency maze procedure achieves sinus rhythm in 45%–95% of patients treated for atrial fibrillation. This retrospective study evaluates mid-term results of the radiofrequency maze—performed concomitant to elective cardiac surgery—to determine sinus-rhythm predictive factors, and describes the evolution of patients' echocardiographic variables. From 2003 through 2011, 247 patients (mean age, 64 ± 9.5 yr) with structural heart disease (79.3% mitral disease) and atrial fibrillation underwent a concomitant radiofrequency modified maze procedure. Patients were monitored by 24-hour Holter at 3, 6, 12, and 24 months, then annually. Eighty-four mitral-valve patients underwent regular echocardiographic follow-up. Univariate and multivariate analysis for risk factors of maze failure were identified. The in-hospital mortality rate was 1.2%. During a median follow-up of 39.4 months, the late mortality rate was 3.6%, and pacemaker insertion was necessary in 26 patients (9.4%). Sinus rhythm was present in 63% of patients at the latest follow-up. Predictive factors for atrial fibrillation recurrence were arrhythmia duration (hazard ratio [HR]=1.296, P=0.045) and atrial fibrillation at hospital discharge (HR=2.03, P=0.019). The monopolar device favored maze success (HR=0.191, P <0.0001). Left atrial area and indexed left ventricular end-diastolic volume showed significant decrease both in sinus rhythm and atrial fibrillation patients. Early sinus rhythm conversion was associated with improved left ventricular ejection fraction. Concomitant radiofrequency maze procedure provided remarkable outcomes. Shorter preoperative atrial fibrillation duration, monopolar device use, and prompt treatment of arrhythmia recurrences increase the midterm success rate. Early sinus rhythm restoration seems to result in better left ventricular ejection fraction recovery. PMID:26413016

  4. Manual Intracardiac Electrogram Method Is Accurate Alternative to Echocardiography for Atrioventricular and Interventricular Optimization in Cardiac Resynchronization Therapy.

    PubMed

    Pezo Nikolić, Borka; Lovrić, Daniel; Ljubas Maček, Jana; Rešković Lukšić, Vlatka; Matasić, Richard; Šeparović Hanževački, Jadranka

    2017-12-01

    Some manufacturers do not provide automated intracardiac electrogram method (IEGM) systems for atrioventricular (AV) and interventricular (VV) delay optimization in cardiac resynchronization therapy (CRT). We aimed to evaluate the accuracy of manual IEGM method in 48 patients previously implanted with Medtronic Syncra CRT. All patients underwent standard device interrogation followed by CRT optimization by IEGM method and by echocardiography one month after implantation. The patient mean age was 60.7±11.8 years and there were 33 (68.8%) males. After CRT implantation, the left ventricular ejection fraction increased from 28.0±7.9% to 39.1±11.0% (p<0.001). Optimal aortic flow Velocity Time Integral (aVTI) was obtained when VV was set to 20-50 ms left ventricular pre-activation. There was a strong correlation between VV values determined by echocardiography and IEGM (R=0.823, p<0.001). We found no significant difference in AV, VV and aVTI values between echocardiography and IEGM method. However, IEGM was significantly less time-consuming than echocardiography [20 (10-28) vs. 40 (35-60) minutes, p<0.001]. Manual IEGM method may be good alternative to echocardiography and automated IEGM method. It also emphasizes the need for implementation of automated IEGM systems in as many CRT devices as possible.

  5. Rescue pulmonary vein isolation for hemodynamically unstable atrial fibrillation storm in a patient with an acute extensive myocardial infarction.

    PubMed

    Morishima, Itsuro; Sone, Takahito; Tsuboi, Hideyuki; Mukawa, Hiroaki

    2012-11-26

    New-onset atrial fibrillation in patients hospitalized for an acute myocardial infarction often leads to hemodynamic deterioration and has serious adverse prognostic implications; mortality is particularly high in patients with congestive heart failure and/or a reduced left ventricular ejection fraction. The mechanism of atrial fibrillation in the context of an acute myocardial infarction has not been well characterized and an effective treatment other than optimal medical therapy and mechanical hemodynamic support are expected. A 71 year-old male with an acute myocardial infarction due to an occlusion of the left main coronary artery was treated with percutaneous coronary intervention. He had developed severe congestive heart failure with a left ventricular ejection fraction of 34%. The systemic circulation was maintained with an intraaortic balloon pump, continuous hemodiafiltration, and mechanical ventilation until atrial fibrillation occurred on day 3 which immediately led to cardiogenic shock. Because atrial fibrillation was refractory to intravenous amiodarone, beta-blockers, and a total of 15 electrical cardioversions, the patient underwent emergent radiofrequency catheter ablation on day 4. Soon after electrical cardioversion, ectopies from the right superior pulmonary vein triggered the initiation of atrial fibrillation. The right pulmonary veins were isolated during atrial fibrillation. Again, atrial fibrillation was electrically cardioverted, then, sinus rhythm was restored. Subsequently, the left pulmonary veins were isolated. The stabilization of the hemodynamics was successfully achieved with an increase in the blood pressure and urine volume. Hemodiafiltration and amiodarone were discontinued. The patient had been free from atrial fibrillation recurrence until he suddenly died due to ventricular fibrillation on day 9. To the best of our knowledge, this is the first report of pulmonary vein isolation for a rescue purpose applied in a patient with hemodymically unstable atrial fibrillation complicated with an acute myocardial infarction. This case demonstrates that ectopic activity in the pulmonary veins may be responsible for triggering atrial fibrillation in the critical setting of an acute myocardial infarction and thus pulmonary vein isolation could be an effective therapeutic option.

  6. Impact of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mechanical mitral valve replacement for rheumatic mitral valve disease.

    PubMed

    Wang, Bin; Xu, Zhi-yun; Han, Lin; Zhang, Guan-xin; Lu, Fang-lin; Song, Zhi-gang

    2013-03-01

    The prognostic significance of preoperative atrial fibrillation on mitral valve replacement remains unclear. The aim of this study was to explore the effects of the presence of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mitral valve replacement for rheumatic valve disease. A retrospective analysis was performed on a total of 793 patients who underwent mitral valve replacement with or without tricuspid valve repair in our hospital. The patients selected were divided into two groups according to preoperative rhythm status. Patients with preoperative atrial fibrillation were assigned to the AF group, while patients in preoperative sinus rhythm were assigned to the SR group. Postoperative follow-up was performed by outpatient visits, as well as by telephone and written correspondence. Data gathered included survivorship, postoperative complications, left ventricular function and tricuspid regurgitation. For patients with atrial fibrillation vs those in sinus rhythm, there was no difference in postoperative mortality and morbidity. Follow-up was a mean of 8.6 ± 2.4 years. For patients with preoperative atrial fibrillation, 10-year survival from a Kaplan-Meier curve was 88.7%, compared with 96.6% in patients with preoperative sinus rhythm (P = 0.002). Multivariate analysis identified low left ventricular ejection fraction, older age, large left atrium and preoperative atrial fibrillation as significant adverse predictors for overall survival. Freedom from thromboembolism complications at 13 years was lower for patients with preoperative atrial fibrillation without maze procedure and left atrial appendage ligation, compared with that for patients with preoperative sinus rhythm without maze procedure and left atrial appendage ligation, and patients with concomitant maze procedure and left atrial appendage ligation (76.3 vs 94.8 vs 94.0%, respectively; P = 0.001). On echocardiography, the proportion of patients with significant tricuspid regurgitation was 38.7% (atrial fibrillation patients) vs 25.4% (patients in sinus rhythm; P < 0.001). Left ventricular ejection fraction measured 5 years after surgery increased by an average of 1.2% in the AF group, while it increased by 5.3% in the SR group (P = 0.028). Preoperative atrial fibrillation is a risk factor for long-term mortality, thromboembolism complications and tricuspid regurgitation, and it also has an adverse effect on the degree of improvement when considering left ventricular function.

  7. Evaluation of Right Ventricular Myocardial Mechanics Using Velocity Vector Imaging of Cardiac MRI Cine Images in Transposition of the Great Arteries Following Atrial and Arterial Switch Operations.

    PubMed

    Thattaliyath, Bijoy D; Forsha, Daniel E; Stewart, Chad; Barker, Piers C A; Campbell, Michael J

    2015-01-01

    The aim of the study was to determine right and left ventricle deformation parameters in patients with transposition of the great arteries who had undergone atrial or arterial switch procedures. Patients with transposition are born with a systemic right ventricle. Historically, the atrial switch operation, in which the right ventricle remains the systemic ventricle, was performed. These patients have increased rates of morbidity and mortality. We used cardiac MRI with Velocity Vector Imaging analysis to characterize and compare ventricular myocardial deformation in patients who had an atrial switch or arterial switch operation. Patients with a history of these procedures, who had a clinically ordered cardiac MRI were included in the study. Consecutive 20 patients (75% male, 28.7 ± 1.8 years) who underwent atrial switch operation and 20 patients (60% male, 17.7 ± 1.9 years) who underwent arterial switch operation were included in the study. Four chamber and short-axis cine images were used to determine longitudinal and circumferential strain and strain rate using Vector Velocity Imaging software. Compared with the arterial switch group, the atrial switch group had decreased right ventricular ejection fraction and increased end-diastolic and end-systolic volumes, and no difference in left ventricular ejection fraction and volumes. The atrial switch group had decreased longitudinal and circumferential strain and strain rate. When compared with normal controls multiple strain parameters in the atrial switch group were reduced. Myocardial deformation analysis of transposition patients reveals a reduction of right ventricular function and decreased longitudinal and circumferential strain parameters in patients with an atrial switch operation compared with those with arterial switch operation. A better understanding of the mechanisms of right ventricle failure in transposition of great arteries may lead to improved therapies and adaptation. © 2015 Wiley Periodicals, Inc.

  8. Effects of heart rate on experimentally produced mitral regurgitation in dogs.

    PubMed

    Yoran, C; Yellin, E L; Hori, M; Tsujioka, K; Laniado, S; Sonnenblick, E H; Frater, R W

    1983-12-01

    The effects of increasing heart rate (HR) on the hemodynamics of acute mitral regurgitation (MR) were studied in 8 open-chest dogs. Filling volume, regurgitant volume and stroke volume were calculated from electromagnetic probe measurements of mitral and aortic flows. The left atrial-left ventricular systolic pressure gradient was measured with micromanometers. The calculated effective mitral regurgitant orifice area varied from 10 to 128 mm2, with a consequent regurgitant fraction (regurgitant volume/filling volume) of 24 to 62%. After crushing the sinus node, HR was increased stepwise from 90 to 180 beats/min by atrial pacing while maintaining aortic pressure constant. With increasing HR, filling volume, stroke volume, regurgitant volume and regurgitant time decreased; total cardiac output, forward cardiac output, regurgitant output, systolic pressure gradient, regurgitant fraction and the regurgitant orifice did not change; left ventricular end-diastolic pressure decreased; and left atrial v-wave amplitude increased. These results indicate that in acute experimental MR with a wide spectrum of incompetence, the relative distribution of forward and regurgitant flows did not change with large increases in HR. At rates greater than 150 beats/min the atrial contraction occurs early and increases the amplitude of the left atrial v wave. This may contribute to the severity of pulmonary congestion in patients with MR.

  9. Association of Left Atrial Function and Left Atrial Enhancement in Patients with Atrial Fibrillation: A Cardiac Magnetic Resonance Study

    PubMed Central

    Habibi, Mohammadali; Lima, Joao A.C.; Khurram, Irfan M.; Zimmerman, Stefan L.; Zipunnikov, Vadim; Fukumoto, Kotaro; Spragg, David; Ashikaga, Hiroshi; Rickard, John; Marine, Joseph E.; Calkins, Hugh; Nazarian, Saman

    2015-01-01

    Background Atrial fibrillation (AF) is associated with left atrial (LA) structural and functional changes. Cardiac magnetic resonance (CMR) late gadolinium enhancement (LGE) and feature-tracking are capable of noninvasive quantification of LA fibrosis and myocardial motion, respectively. We sought to examine the association of phasic LA function with LA enhancement in patients with AF. Methods and Results LA structure and function was measured in 90 AF patients (age 61 ± 10 years, 76% male) referred for ablation and 14 healthy volunteers. Peak global longitudinal LA strain (PLAS), LA systolic strain rate (SR-s), and early (SR-ed) and late diastolic (SR-ld) strain rates were measured using cine-CMR images acquired during sinus rhythm. The degree of LGE was quantified. Compared to patients with paroxysmal AF (60% of cohort), those with persistent AF had larger maximum LA volume index (LAVImax, 56 ± 17ml/m2 versus 49 ± 13ml/m2 p=0.036), and increased LGE (27.1± 11.7% versus 36.8 ± 14.8% p<0.001). Aside from LA active emptying fraction, all LA parameters (passive emptying fraction, PLAS, SR-s, SR-ed and SR-ld) were lower in patients with persistent AF (p< 0.05 for all). Healthy volunteers had less LGE and higher LA functional parameters compared to AF patients (p<0.05 for all). In multivariable analysis, increased LGE was associated with lower LA passive emptying fraction, PLAS, SR-s, SR-ed, and SR-ld (p<0.05 for all). Conclusions Increased LA enhancement is associated with decreased LA reservoir, conduit, and booster pump functions. Phasic measurement of LA function using feature-tracking CMR may add important information regarding the physiological importance of LA fibrosis. PMID:25652181

  10. Efficacy of β blockers in patients with heart failure plus atrial fibrillation: an individual-patient data meta-analysis.

    PubMed

    Kotecha, Dipak; Holmes, Jane; Krum, Henry; Altman, Douglas G; Manzano, Luis; Cleland, John G F; Lip, Gregory Y H; Coats, Andrew J S; Andersson, Bert; Kirchhof, Paulus; von Lueder, Thomas G; Wedel, Hans; Rosano, Giuseppe; Shibata, Marcelo C; Rigby, Alan; Flather, Marcus D

    2014-12-20

    Atrial fibrillation and heart failure often coexist, causing substantial cardiovascular morbidity and mortality. β blockers are indicated in patients with symptomatic heart failure with reduced ejection fraction; however, the efficacy of these drugs in patients with concomitant atrial fibrillation is uncertain. We therefore meta-analysed individual-patient data to assess the efficacy of β blockers in patients with heart failure and sinus rhythm compared with atrial fibrillation. We extracted individual-patient data from ten randomised controlled trials of the comparison of β blockers versus placebo in heart failure. The presence of sinus rhythm or atrial fibrillation was ascertained from the baseline electrocardiograph. The primary outcome was all-cause mortality. Analysis was by intention to treat. Outcome data were meta-analysed with an adjusted Cox proportional hazards regression. The study is registered with Clinicaltrials.gov, number NCT0083244, and PROSPERO, number CRD42014010012. 18,254 patients were assessed, and of these 13,946 (76%) had sinus rhythm and 3066 (17%) had atrial fibrillation at baseline. Crude death rates over a mean follow-up of 1·5 years (SD 1·1) were 16% (2237 of 13,945) in patients with sinus rhythm and 21% (633 of 3064) in patients with atrial fibrillation. β-blocker therapy led to a significant reduction in all-cause mortality in patients with sinus rhythm (hazard ratio 0·73, 0·67-0·80; p<0·001), but not in patients with atrial fibrillation (0·97, 0·83-1·14; p=0·73), with a significant p value for interaction of baseline rhythm (p=0·002). The lack of efficacy for the primary outcome was noted in all subgroups of atrial fibrillation, including age, sex, left ventricular ejection fraction, New York Heart Association class, heart rate, and baseline medical therapy. Based on our findings, β blockers should not be used preferentially over other rate-control medications and not regarded as standard therapy to improve prognosis in patients with concomitant heart failure and atrial fibrillation. Menarini Farmaceutica Internazionale (administrative support grant). Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography.

    PubMed

    Shen, Jiaqi; Zhou, Qiao; Liu, Yue; Luo, Runlan; Tan, Bijun; Li, Guangsen

    2016-08-23

    Iron-deficiency anemia (IDA) is a global health problem and a common medical condition that can be seen in everyday clinical practice. And two-dimensional speckle tracking echocardiography (2D-STE) has been reported very useful in evaluating left atrial (LA) function, as well as left ventricular (LV) function. The aim of our study is to evaluate the LA function in patients with IDA by 2D-STE. 65 patients with IDA were selected. This group of patients was then divided into two groups according to the degree of hemoglobin: group B (Hb > 90 g/L) and group C (Hb60 ~ 90 g/L). Another 30 healthy people were also selected as control group A. Conventional echocardiography parameters, such as left atrial diameter (LAD), peak E and A of mitralis (E, A), E/A, end-diastolic thickness of ventricular septum (IVST d), end-diastolic thickness of LV posterior wall (PWTd) and left ventricular end-diastolic dimension (LVDd) were obtained from these three groups. Left atrial minimum volume (LAVmin), left atrial pre-atrial contraction volume (LAVp) and left atrial maximum volume (LAVmax) were measured by Simpson's rule, whereas left atrial active ejection fraction (LAAEF) and left atrial passive ejection fraction (LAPEF) were obtained from calculation. Two-dimensional images were acquired from apical four-chamber view and two-chamber view to store images for offline analysis. The global peak atrial longitudinal strain and strain rate of systolic LV (GLSs, GLSRs) as well as early and late diastolic LV strain rate (GLSRe, GLSRa) curves of LA were acquired in each LA segment from basal segment to top segment of LA by 2D-STE. Compared with group A, there were no differences between group B and group A (all P > 0.05). The LAAEF and GLSRa were significantly higher in group C compared with those of group A and group B (all P < 0.01). The LAPEF, GLSs, GLSRs and GLSRe were significantly lower in group C compared with those of group A and group B (all P < 0.01). 2D-STE could evaluate the LA function in patients with IDA.

  12. Ablation as targeted perturbation to rewire communication network of persistent atrial fibrillation

    PubMed Central

    Tao, Susumu; Way, Samuel F.; Garland, Joshua; Chrispin, Jonathan; Ciuffo, Luisa A.; Balouch, Muhammad A.; Nazarian, Saman; Spragg, David D.; Marine, Joseph E.; Berger, Ronald D.; Calkins, Hugh

    2017-01-01

    Persistent atrial fibrillation (AF) can be viewed as disintegrated patterns of information transmission by action potential across the communication network consisting of nodes linked by functional connectivity. To test the hypothesis that ablation of persistent AF is associated with improvement in both local and global connectivity within the communication networks, we analyzed multi-electrode basket catheter electrograms of 22 consecutive patients (63.5 ± 9.7 years, 78% male) during persistent AF before and after the focal impulse and rotor modulation-guided ablation. Eight patients (36%) developed recurrence within 6 months after ablation. We defined communication networks of AF by nodes (cardiac tissue adjacent to each electrode) and edges (mutual information between pairs of nodes). To evaluate patient-specific parameters of communication, thresholds of mutual information were applied to preserve 10% to 30% of the strongest edges. There was no significant difference in network parameters between both atria at baseline. Ablation effectively rewired the communication network of persistent AF to improve the overall connectivity. In addition, successful ablation improved local connectivity by increasing the average clustering coefficient, and also improved global connectivity by decreasing the characteristic path length. As a result, successful ablation improved the efficiency and robustness of the communication network by increasing the small-world index. These changes were not observed in patients with AF recurrence. Furthermore, a significant increase in the small-world index after ablation was associated with synchronization of the rhythm by acute AF termination. In conclusion, successful ablation rewires communication networks during persistent AF, making it more robust, efficient, and easier to synchronize. Quantitative analysis of communication networks provides not only a mechanistic insight that AF may be sustained by spatially localized sources and global connectivity, but also patient-specific metrics that could serve as a valid endpoint for therapeutic interventions. PMID:28678805

  13. Vdrive Evaluation of Remote Steering and Testing in Lasso Electrophysiology Procedures Study: The VERSATILE Study in Atrial Fibrillation Ablation.

    PubMed

    Nölker, Georg; Schwagten, Bruno; Deville, J Brian; Burkhardt, J David; Horton, Rodney P; Sha, Qun; Tomassoni, Gery

    2016-03-01

    Circular mapping catheters (CMC) are an essential tool in most atrial fibrillation ablation procedures. The Vdrive™ with V-Loop™ system enables a physician to remotely manipulate a CMC during electrophysiology studies. Our aim was to compare the clinical performance of the system to conventional CMC navigation according to efficiency and safety endpoints. A total of 120 patients scheduled to undergo a CMC study followed by pulmonary vein isolation (PVI) were included. Treatment allocation was randomized 2:1, remote navigation:manual navigation. The primary effectiveness endpoint was assessed based on both successful navigation to the targeted pulmonary vein (PV) and successful recording of PV electrograms. All PVs were treated independently within and between patients. The primary safety endpoint was assessed based on the occurrence of major adverse events (MAEs) through seven days after the study procedure. Primary effectiveness endpoints were achieved in 295/302 PVs in the Vdrive arm (97.7%) and 167/167 PVs in the manual arm (100%). Effectiveness analysis indicates Vdrive non-inferiority (pnon-inferiority = 0.0405; δ = -0.05) per the Cochran-Mantel-Haenszel test adjusted for PV correlation. Five MAEs related to the ablation procedure occurred (three in the Vdrive arm-3.9%; two in the manual arm-2.33%). No device-related MAEs were observed; safety analysis indicates Vdrive non-inferiority (pnon-inferiority = 0.0441; δ = 0.07) per the normal Z test. Remote navigation of a CMC is equivalent to manual in PVI in terms of safety and effectiveness. This allows for single-operator procedures in conjunction with a magnetically guided ablation catheter. © 2016 Wiley Periodicals, Inc.

  14. The relationship between atrial electromechanical delay and left atrial mechanical function in stroke patients

    PubMed Central

    Akıl, Mehmet Ata; Akıl, Eşref; Bilik, Mehmet Zihni; Oylumlu, Mustafa; Acet, Halit; Yıldız, Abdülkadir; Akyüz, Abdurrahman; Ertaş, Faruk; Toprak, Nizamettin

    2015-01-01

    Objective: The aim of this study was to evaluate the relationship between atrial electromechanical delay (EMD) measured with tissue Doppler imaging (TDI) and left atrial (LA) mechanical functions in patients with ischemic stroke and compare them with healthy controls. Methods: Thirty patients with ischemic stroke were enrolled into this cross-sectional, observational study. The control group consisted of 35 age- and gender-matched apparently healthy individuals patients. Acute cerebral infarcts of probable embolic origin were diagnosed via imaging and were confirmed by a neurologist. Echocardiographically, time intervals from the beginning of P wave to beginning of A wave from the lateral and septal mitral and right ventricular tricuspid annuli in TDI were recorded. The differences between these intervals gave the mechanical delays (inter- and intra-atrial). Left atrial (LA) volumes were measured using the biplane area-length method, and LA mechanical function parameters were calculated. Statistical analysis was performed using student’s t-test, chi-squared test, and Pearson’s test. Results: The laboratory and clinical characteristics were similar in the two groups. Increased left atrial EMD (21.36±10.38 ms versus 11.74±6.06 ms, p<0.001), right atrial EMD (13.66±8.62 ms versus 9.66±6.81 ms, p=0.040), and interatrial EMD (35.03±9.95 ms versus 21.40±8.47 ms, p<0.001) were observed in stroke patients as compared to controls. Active LA emptying volume and fraction and passive LA emptying volumes and fraction were similar between controls and stroke patients. Total LA emptying volumes were significantly increased in stroke patients as compared to healthy controls (33.19±11.99 mL/m2 versus 27.48±7.08 mL/m2, p=0.021). Conclusion: According to the results of our study, interatrial electromechanical delay may be a new predictor for ischemic stroke. PMID:25537998

  15. Measurement of funny current (I(f)) channel mRNA in human atrial tissue: correlation with left atrial filling pressure and atrial fibrillation.

    PubMed

    Lai, L P; Su, M J; Lin, J L; Tsai, C H; Lin, F Y; Chen, Y S; Hwang, J J; Huang, S K; Tseng, Y Z; Lien, W P

    1999-07-01

    The funny current (I(f)) contributes to phase IV spontaneous depolarization in cardiac pacemaker tissue. Enhanced I(f) activity in myocardial tissue may lead to increased automaticity and therefore tachyarrhythmia. We measured the amount of I(f) activity in the messenger ribonucleic acid (mRNA) in human atrial tissue and correlated the mRNA amount to left atrial filling pressure and atrial fibrillation (AF). A total of 34 patients undergoing open heart surgery were included (15 men and 19 women, aged 55+/-10 years). Atrial tissue was obtained from the right atrial free wall, the right atrial appendage, the left atrial free wall, and the left atrial appendage, respectively. The mRNA amount of the I(f) channel was measured by reverse transcription polymerase chain reaction and was normalized to the mRNA levels of glyceraldehyde 3-phosphate dehydrogenase. We found that the I(f) channel mRNA was present at all the atrial sampling sites. A higher left atrial filling pressure, an indicator of congestive heart failure, was associated with a higher I(f) mRNA level (r2 = 0.446, P < 0.01 by linear regression). We also found that the mRNA amount was significantly higher in patients with AF than in patients without AF (1.68+/-0.49 vs 1.27+/-0.43; P < 0.05). Age, sex, right atrial filling pressure, left atrial dimension, and left ventricular ejection fraction had no significant effect on the mRNA level. The mRNA of the I(f) channel is present in the free-wall area and appendage area from both atria. Increased left atrial filling pressure and clinical AF are associated with increased I(f) mRNA level.

  16. 3D patient-specific models for left atrium characterization to support ablation in atrial fibrillation patients.

    PubMed

    Valinoti, Maddalena; Fabbri, Claudio; Turco, Dario; Mantovan, Roberto; Pasini, Antonio; Corsi, Cristiana

    2018-01-01

    Radiofrequency ablation (RFA) is an important and promising therapy for atrial fibrillation (AF) patients. Optimization of patient selection and the availability of an accurate anatomical guide could improve RFA success rate. In this study we propose a unified, fully automated approach to build a 3D patient-specific left atrium (LA) model including pulmonary veins (PVs) in order to provide an accurate anatomical guide during RFA and without PVs in order to characterize LA volumetry and support patient selection for AF ablation. Magnetic resonance data from twenty-six patients referred for AF RFA were processed applying an edge-based level set approach guided by a phase-based edge detector to obtain the 3D LA model with PVs. An automated technique based on the shape diameter function was designed and applied to remove PVs and compute LA volume. 3D LA models were qualitatively compared with 3D LA surfaces acquired during the ablation procedure. An expert radiologist manually traced the LA on MR images twice. LA surfaces from the automatic approach and manual tracing were compared by mean surface-to-surface distance. In addition, LA volumes were compared with volumes from manual segmentation by linear and Bland-Altman analyses. Qualitative comparison of 3D LA models showed several inaccuracies, in particular PVs reconstruction was not accurate and left atrial appendage was missing in the model obtained during RFA procedure. LA surfaces were very similar (mean surface-to-surface distance: 2.3±0.7mm). LA volumes were in excellent agreement (y=1.03x-1.4, r=0.99, bias=-1.37ml (-1.43%) SD=2.16ml (2.3%), mean percentage difference=1.3%±2.1%). Results showed the proposed 3D patient-specific LA model with PVs is able to better describe LA anatomy compared to models derived from the navigation system, thus potentially improving electrograms and voltage information location and reducing fluoroscopic time during RFA. Quantitative assessment of LA volume derived from our 3D LA model without PVs is also accurate and may provide important information for patient selection for RFA. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. A Prospective Study of Ripple Mapping the Post-Infarct Ventricular Scar to Guide Substrate Ablation for Ventricular Tachycardia.

    PubMed

    Luther, Vishal; Linton, Nick W F; Jamil-Copley, Shahnaz; Koa-Wing, Michael; Lim, Phang Boon; Qureshi, Norman; Ng, Fu Siong; Hayat, Sajad; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa

    2016-06-01

    Post-infarct ventricular tachycardia is associated with channels of surviving myocardium within scar characterized by fractionated and low-amplitude signals usually occurring late during sinus rhythm. Conventional automated algorithms for 3-dimensional electro-anatomic mapping cannot differentiate the delayed local signal of conduction within the scar from the initial far-field signal generated by surrounding healthy tissue. Ripple mapping displays every deflection of an electrogram, thereby providing fully informative activation sequences. We prospectively used CARTO-based ripple maps to identify conducting channels as a target for ablation. High-density bipolar left ventricular endocardial electrograms were collected using CARTO3v4 in sinus rhythm or ventricular pacing and reviewed for ripple mapping conducting channel identification. Fifteen consecutive patients (median age 68 years, left ventricular ejection fraction 30%) were studied (6 month preprocedural implantable cardioverter defibrillator therapies: median 19 ATP events [Q1-Q3=4-93] and 1 shock [Q1-Q3=0-3]). Scar (<1.5 mV) occupied a median 29% of the total surface area (median 540 points collected within scar). A median of 2 ripple mapping conducting channels were seen within each scar (length 60 mm; initial component 0.44 mV; delayed component 0.20 mV; conduction 55 cm/s). Ablation was performed along all identified ripple mapping conducting channels (median 18 lesions) and any presumed interconnected late-activating sites (median 6 lesions; Q1-Q3=2-12). The diastolic isthmus in ventricular tachycardia was mapped in 3 patients and colocated within the ripple mapping conducting channels identified. Ventricular tachycardia was noninducible in 85% of patients post ablation, and 71% remain free of ventricular tachycardia recurrence at 6-month median follow-up. Ripple mapping can be used to identify conduction channels within scar to guide functional substrate ablation. © 2016 American Heart Association, Inc.

  18. Software algorithm and hardware design for real-time implementation of new spectral estimator

    PubMed Central

    2014-01-01

    Background Real-time spectral analyzers can be difficult to implement for PC computer-based systems because of the potential for high computational cost, and algorithm complexity. In this work a new spectral estimator (NSE) is developed for real-time analysis, and compared with the discrete Fourier transform (DFT). Method Clinical data in the form of 216 fractionated atrial electrogram sequences were used as inputs. The sample rate for acquisition was 977 Hz, or approximately 1 millisecond between digital samples. Real-time NSE power spectra were generated for 16,384 consecutive data points. The same data sequences were used for spectral calculation using a radix-2 implementation of the DFT. The NSE algorithm was also developed for implementation as a real-time spectral analyzer electronic circuit board. Results The average interval for a single real-time spectral calculation in software was 3.29 μs for NSE versus 504.5 μs for DFT. Thus for real-time spectral analysis, the NSE algorithm is approximately 150× faster than the DFT. Over a 1 millisecond sampling period, the NSE algorithm had the capability to spectrally analyze a maximum of 303 data channels, while the DFT algorithm could only analyze a single channel. Moreover, for the 8 second sequences, the NSE spectral resolution in the 3-12 Hz range was 0.037 Hz while the DFT spectral resolution was only 0.122 Hz. The NSE was also found to be implementable as a standalone spectral analyzer board using approximately 26 integrated circuits at a cost of approximately $500. The software files used for analysis are included as a supplement, please see the Additional files 1 and 2. Conclusions The NSE real-time algorithm has low computational cost and complexity, and is implementable in both software and hardware for 1 millisecond updates of multichannel spectra. The algorithm may be helpful to guide radiofrequency catheter ablation in real time. PMID:24886214

  19. Triggers of sustained monomorphic ventricular tachycardia differ among patients with varying etiologies of left ventricular dysfunction.

    PubMed

    Rosman, Jonathan; Hanon, Sam; Shapiro, Michael; Evans, Steven J; Schweitzer, Paul

    2006-04-01

    The mechanisms underlying the initiation of sustained ventricular tachycardia (VT) have not been fully elucidated. The extent to which reentry, abnormal automaticity, and triggered activity play a role in VT differs depending on the etiology of left ventricular dysfunction. By analyzing electrograms from implantable cardioverter defibrillator (ICD), we sought to determine whether there were differences in VT initiation patterns between patients with ischemic and nonischemic cardiomyopathy. We analyzed ICD electrograms in patients with ejection fractions < 40% who had sustained VT over a 27-month period. The trigger for VT onset was classified as a ventricular premature beat (VPB), supraventricular tachycardia, or of "sudden onset." The baseline cycle length, VT cycle length, coupling interval, and prematurity ratio were recorded for each event. The prematurity ratio was calculated as the coupling interval of the VT initiator divided by the baseline cycle length. Sixty-three VT events in 14 patients met the inclusion criteria. A VPB initiated the VT in 58 episodes (92%), 1 episode (2%) was initiated by a supraventricular tachycardia, and 4 episodes (6%) were sudden onset. The prematurity ratio was significantly higher (P < 0.05) in patients with ischemic cardiomyopathy (0.751 +/- 0.068) as compared to patients with nonischemic cardiomyopathy (0.604 +/- 0.139). VPBs initiated most sustained VT episodes. A significantly higher prematurity ratio was observed in the ischemic heart disease group. This may represent different mechanisms of VT initiation in patients with ischemic versus nonischemic heart disease.

  20. Interatrial septal motion as a novel index to predict left atrial pressure.

    PubMed

    Masai, Kumiko; Kishima, Hideyuki; Takahashi, Satoshi; Ashida, Kenki; Goda, Akiko; Mine, Takanao; Asakura, Masanori; Ishihara, Masaharu; Masuyama, Tohru

    2018-01-22

    We investigated whether the interatrial septal (IAS) motion of each heartbeat which is observed by transesophageal echocardiography reflects left atrial pressure (LAP) in patients with atrial fibrillation (AF). We studied 100 patients (70 males, age 67 ± 9 years) who underwent catheter ablation for AF. The amplitude of IAS motion was measured using M-mode and averaged for five cardiac cycles. Left and right atrial pressures, the left to right atrial pressure gradient were directly measured during the catheter ablation. In patients with sinus rhythm during measurement, elevated mean LAP, larger maximum left to right atrial pressure gradient, and greater left atrial emptying fraction were associated with IAS motion. The optimal cut-off value of the IAS motion for predicting high LAP (mean LAP > 15 mmHg) was 8.5 mm (sensitivity 100%, specificity 70.1%) in patients with sinus rhythm during pressure measurement. In addition, all patients were divided into 6 groups based on rhythm during measurement and cutoff value of IAS motion. In patients with sinus rhythm during measurement, low IAS motion group had a highest prevalence of elevated LAP compared with high IAS motion group (64 vs. 0%, P < 0.0001). The amplitude of interatrial septal motion during sinus rhythm reflects left atrial pressure in patients with atrial fibrillation. Interatrial septal motion could be a new index to predict elevated left atrial pressure.

  1. Effects of chronic omega-3 polyunsaturated fatty acid supplementation on human atrial mechanical function after reversion of atrial arrhythmias to sinus rhythm: reversal of tachycardia-mediated atrial cardiomyopathy with fish oils.

    PubMed

    Kumar, Saurabh; Sutherland, Fiona; Wheeler, Miriam; Heck, Patrick M; Lee, Geoffrey; Teh, Andrew W; Garg, Manohar L; Morgan, John G; Sparks, Paul B

    2011-05-01

    Atrial mechanical stunning is a form of tachycardia-mediated atrial cardiomyopathy that manifests after reversion of persistent atrial arrhythmias to sinus rhythm. This study sought to examine whether chronic omega-3 polyunsaturated fatty acid supplementation with fish oils can reverse atrial mechanical stunning. Patients undergoing reversion of persistent atrial fibrillation (AF) or atrial flutter (AFL) to sinus rhythm were randomized to a control group (n = 26) or an omega-3 group (n = 23). The latter were prescribed 6 g/day of fish oil for ≥1 month prior to the procedure. Parameters of left atrial appendage function were compared immediately before and immediately after reversion. After fish oil intake for a mean of 70 days, the following were noted favoring the omega-3 group among both AF and AFL patients: (1) 2-fold higher serum omega-3 levels (P < .001), (2) less mean decrease in emptying velocity (e.g., AF: 8% vs. 32%, P = .02), (3) less mean decrease in appendage emptying fraction (e.g., AFL: 7% vs. 60%, P = .002), (4) lower incidence of new or increased spontaneous echocardiographic contrast (e.g., AF: 11% vs. 62.5%, P = .003), and (5) lower incidence of atrial mechanical stunning (e.g., AFL: 20% vs. 100%, P = .001). Omega-3 intake conferred protection against stunning in a multivariable analysis (odds ratio 0.18, P = .02). Chronic fish oil ingestion in humans attenuates atrial mechanical stunning after reversion of atrial arrhythmias to sinus rhythm. This suggests that fish oils may target or even reverse underlying cellular and/or structural remodeling that occurs in response to persistent atrial arrhythmias. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  2. P-wave characteristics on routine preoperative electrocardiogram improve prediction of new-onset postoperative atrial fibrillation in cardiac surgery.

    PubMed

    Wong, Jim K; Lobato, Robert L; Pinesett, Andre; Maxwell, Bryan G; Mora-Mangano, Christina T; Perez, Marco V

    2014-12-01

    To test the hypothesis that including preoperative electrocardiogram (ECG) characteristics with clinical variables significantly improves the new-onset postoperative atrial fibrillation prediction model. Retrospective analysis. Single-center university hospital. Five hundred twenty-six patients, ≥ 18 years of age, who underwent coronary artery bypass grafting, aortic valve replacement, mitral valve replacement/repair, or a combination of valve surgery and coronary artery bypass grafting requiring cardiopulmonary bypass. Retrospective review of medical records. Baseline characteristics and cardiopulmonary bypass times were collected. Digitally-measured timing and voltages from preoperative electrocardiograms were extracted. Postoperative atrial fibrillation was defined as atrial fibrillation requiring therapeutic intervention. Two hundred eight (39.5%) patients developed postoperative atrial fibrillation. Clinical predictors were age, ejection fraction<55%, history of atrial fibrillation, history of cerebral vascular event, and valvular surgery. Three ECG parameters associated with postoperative atrial fibrillation were observed: Premature atrial contraction, p-wave index, and p-frontal axis. Adding electrocardiogram variables to the prediction model with only clinical predictors significantly improved the area under the receiver operating characteristic curve, from 0.71 to 0.78 (p<0.01). Overall net reclassification improvement was 0.059 (p = 0.09). Among those who developed postoperative atrial fibrillation, the net reclassification improvement was 0.063 (p = 0.03). Several p-wave characteristics are independently associated with postoperative atrial fibrillation. Addition of these parameters improves the postoperative atrial fibrillation prediction model. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Efficient computation of electrograms and ECGs in human whole heart simulations using a reaction-eikonal model.

    PubMed

    Neic, Aurel; Campos, Fernando O; Prassl, Anton J; Niederer, Steven A; Bishop, Martin J; Vigmond, Edward J; Plank, Gernot

    2017-10-01

    Anatomically accurate and biophysically detailed bidomain models of the human heart have proven a powerful tool for gaining quantitative insight into the links between electrical sources in the myocardium and the concomitant current flow in the surrounding medium as they represent their relationship mechanistically based on first principles. Such models are increasingly considered as a clinical research tool with the perspective of being used, ultimately, as a complementary diagnostic modality. An important prerequisite in many clinical modeling applications is the ability of models to faithfully replicate potential maps and electrograms recorded from a given patient. However, while the personalization of electrophysiology models based on the gold standard bidomain formulation is in principle feasible, the associated computational expenses are significant, rendering their use incompatible with clinical time frames. In this study we report on the development of a novel computationally efficient reaction-eikonal (R-E) model for modeling extracellular potential maps and electrograms. Using a biventricular human electrophysiology model, which incorporates a topologically realistic His-Purkinje system (HPS), we demonstrate by comparing against a high-resolution reaction-diffusion (R-D) bidomain model that the R-E model predicts extracellular potential fields, electrograms as well as ECGs at the body surface with high fidelity and offers vast computational savings greater than three orders of magnitude. Due to their efficiency R-E models are ideally suitable for forward simulations in clinical modeling studies which attempt to personalize electrophysiological model features.

  4. Efficient computation of electrograms and ECGs in human whole heart simulations using a reaction-eikonal model

    NASA Astrophysics Data System (ADS)

    Neic, Aurel; Campos, Fernando O.; Prassl, Anton J.; Niederer, Steven A.; Bishop, Martin J.; Vigmond, Edward J.; Plank, Gernot

    2017-10-01

    Anatomically accurate and biophysically detailed bidomain models of the human heart have proven a powerful tool for gaining quantitative insight into the links between electrical sources in the myocardium and the concomitant current flow in the surrounding medium as they represent their relationship mechanistically based on first principles. Such models are increasingly considered as a clinical research tool with the perspective of being used, ultimately, as a complementary diagnostic modality. An important prerequisite in many clinical modeling applications is the ability of models to faithfully replicate potential maps and electrograms recorded from a given patient. However, while the personalization of electrophysiology models based on the gold standard bidomain formulation is in principle feasible, the associated computational expenses are significant, rendering their use incompatible with clinical time frames. In this study we report on the development of a novel computationally efficient reaction-eikonal (R-E) model for modeling extracellular potential maps and electrograms. Using a biventricular human electrophysiology model, which incorporates a topologically realistic His-Purkinje system (HPS), we demonstrate by comparing against a high-resolution reaction-diffusion (R-D) bidomain model that the R-E model predicts extracellular potential fields, electrograms as well as ECGs at the body surface with high fidelity and offers vast computational savings greater than three orders of magnitude. Due to their efficiency R-E models are ideally suitable for forward simulations in clinical modeling studies which attempt to personalize electrophysiological model features.

  5. Cardiac Magnetic Resonance-Measured Left Atrial Volume and Function and Incident Atrial Fibrillation: Results From MESA (Multi-Ethnic Study of Atherosclerosis).

    PubMed

    Habibi, Mohammadali; Samiei, Sanaz; Ambale Venkatesh, Bharath; Opdahl, Anders; Helle-Valle, Thomas M; Zareian, Mytra; Almeida, Andre L C; Choi, Eui-Young; Wu, Colin; Alonso, Alvaro; Heckbert, Susan R; Bluemke, David A; Lima, João A C

    2016-08-01

    Early detection of structural changes in left atrium (LA) before atrial fibrillation (AF) development could be helpful in identification of those at higher risk for AF. Using cardiac magnetic resonance imaging, we examined the association of LA volume and function, and incident AF in a multiethnic population free of clinical cardiovascular diseases. In a case-cohort study embedded in MESA (Multi-Ethnic Study of Atherosclerosis), baseline LA size and function assessed by cardiac magnetic resonance feature-tracking were compared between 197 participants with incident AF and 322 participants randomly selected from the whole MESA cohort. Participants were followed up for 8 years. Incident AF cases had a larger LA volume and decreased passive, active, and total LA emptying fractions and peak global LA longitudinal strain (peak LA strain) at baseline. In multivariable analysis, elevated LA maximum volume index (hazard ratio, 1.38 per SD; 95% confidence interval, 1.01-1.89) and decreased peak LA strain (hazard ratio, 0.68 per SD; 95% confidence interval, 0.48-0.96), and passive and total LA emptying fractions (hazard ratio for passive LA emptying fractions, 0.55 per SD; 95% confidence interval, 0.40-0.75 and hazard ratio for active LA emptying fractions, 0.70 per SD; 95% confidence interval, 0.52-0.95), but not active LA emptying fraction, were associated with incident AF. Elevated LA volumes and decreased passive and total LA emptying fractions were independently associated with incident AF in an asymptomatic multiethnic population. Including LA functional variables along with other risk factors of AF may help to better risk stratify individuals at risk of AF development. © 2016 American Heart Association, Inc.

  6. Atrial conduction times and left atrial mechanical functions and their relation with diastolic function in prediabetic patients.

    PubMed

    Gudul, Naile Eris; Karabag, Turgut; Sayin, Muhammet Rasit; Bayraktaroglu, Taner; Aydin, Mustafa

    2017-03-01

    The aim of this study was to investigate atrial conduction times and left atrial mechanical functions, the noninvasive predictors of atrial fibrillation, in prediabetic patients with impaired fasting glucose (IFG) and impaired glucose tolerance (IGT). Study included 59 patients (23 males, 36 females; mean age 52.5 ± 10.6 years) diagnosed with IFG or IGT by the American Diabetes Association criteria, and 43 healthy adults (22 males, 21 females; mean age 48.5 ± 12.1 years). Conventional and tissue Doppler echocardiography were performed. The electromechanical delay parameters were measured from the onset of the P wave on the surface electrocardiogram to the onset of the atrial systolic wave on tissue Doppler imaging from septum, lateral, and right ventricular annuli. The left atrial volumes were calculated by the disk method. Left atrial mechanical functions were calculated. The mitral E/A and E'/A' ratios measured from the lateral and septal annuli were significantly lower in the prediabetics compared to the controls. The interatrial and left atrial electromechanical delay were significantly longer in prediabetic group compared to the controls. Left atrial active emptying volume (LAAEV) and fraction (LAAEF) were significantly higher in the prediabetics than the controls. LAAEV and LAAEF were significantly correlated with E/A, lateral and septal E'/A'. In the prediabetic patients, the atrial conduction times and P wave dispersion on surface electrocardiographic were longer before the development of overt diabetes. In addition, the left atrial mechanical functions were impaired secondary to a deterioration in the diastolic functions in the prediabetic patients.

  7. Dynamic characteristic mechanism of atrial septal defect using real-time three-dimensional echocardiography and evaluation of right ventricular functions.

    PubMed

    Sharen, Gao-Wa; Zhang, Jun; Qin, Chuan; Lv, Qing

    2017-02-01

    The dynamic characteristics of the area of the atrial septal defect (ASD) were evaluated using the technique of real-time three-dimensional echocardiography (RT 3DE), the potential factors responsible for the dynamic characteristics of the area of ASD were observed, and the overall and local volume and functions of the patients with ASD were measured. RT 3DE was performed on the 27 normal controls and 28 patients with ASD. Based on the three-dimensional data workstations, the area of ASD was measured at P wave vertex, R wave vertex, T wave starting point, and T wave terminal point and in the T-P section. The right atrial volume in the same time phase of the cardiac cycle and the motion displacement distance of the tricuspid annulus in the corresponding period were measured. The measured value of the area of ASD was analyzed. The changes in the right atrial volume and the motion displacement distance of the tricuspid annulus in the normal control group and the ASD group were compared. The right ventricular ejection fractions in the normal control group and the ASD group were compared using the RT 3DE long-axis eight-plane (LA 8-plane) method. Real-time three-dimensional volume imaging was performed in the normal control group and ASD group (n=30). The right ventricular inflow tract, outflow tract, cardiac apex muscular trabecula dilatation, end-systolic volume, overall dilatation, end-systolic volume, and appropriate local and overall ejection fractions in both two groups were measured with the four-dimensional right ventricular quantitative analysis method (4D RVQ) and compared. The overall right ventricular volume and the ejection fraction measured by the LA 8-plane method and 4D RVQ were subjected to a related analysis. Dynamic changes occurred to the area of ASD in the cardiac cycle. The rules for dynamic changes in the area of ASD and the rules for changes in the right atrial volume in the cardiac cycle were consistent. The maximum value of the changes in the right atrial volume occurred in the end-systolic period when the peak of the curve appeared. The minimum value of the changes occurred in the end-systolic period and was located at the lowest point of the volume variation curve. The area variation curve for ASD and the motion variation curve for the tricuspid annulus in the cardiac cycle were the same. The displacement of the tricuspid annulus exhibited directionality. The measured values of the area of ASD at P wave vertex, R wave vertex, T wave starting point, T wave terminal point and in the T-P section were properly correlated with the right atrial volume (P<0.001). The area of ASD and the motion displacement distance of the tricuspid annulus were negatively correlated (P<0.05). The right atrial volumes in the ASD group in the cardiac cycle in various time phases increased significantly as compared with those in the normal control group (P=0.0001). The motion displacement distance of the tricuspid annulus decreased significantly in the ASD group as compared with that in the normal control group (P=0.043). The right ventricular ejection fraction in the ASD group was lower than that in the normal control group (P=0.032). The ejection fraction of the cardiac apex trabecula of the ASD patients was significantly lower than the ejection fractions of the right ventricular outflow tract and inflow tract and overall ejection fraction. The difference was statistically significant (P=0.005). The right ventricular local and overall dilatation and end-systolic volumes in the ASD group increased significantly as compared with those in the normal control group (P=0.031). The aRVEF and the overall ejection fraction decreased in the ASD group as compared with those in the normal control group (P=0.0005). The dynamic changes in the area of ASD and the motion curves for the right atrial volume and tricuspid annulus have the same dynamic characteristics. RT 3DE can be used to accurately evaluate the local and overall volume and functions of the right ventricle. The local and overall volume loads of the right ventricle in the ASD patients increase significantly as compared with those of the normal people. The right ventricular cardiac apex and the overall systolic function decrease.

  8. Catheter ablation of atrial fibrillation in patients with heart failure and preserved ejection fraction.

    PubMed

    Black-Maier, Eric; Ren, Xinru; Steinberg, Benjamin A; Green, Cynthia L; Barnett, Adam S; Rosa, Normita Sta; Al-Khatib, Sana M; Atwater, Brett D; Daubert, James P; Frazier-Mills, Camille; Grant, Augustus O; Hegland, Donald D; Jackson, Kevin P; Jackson, Larry R; Koontz, Jason I; Lewis, Robert K; Sun, Albert Y; Thomas, Kevin L; Bahnson, Tristam D; Piccini, Jonathan P

    2018-05-01

    Few studies have examined outcomes of catheter ablation for atrial fibrillation (AF) in patients with heart failure (HF) with preserved ejection fraction (HFpEF). The purpose of this study was to compare outcomes of AF ablation in patients with HFpEF vs HF with reduced ejection fraction (HFrEF). We performed a retrospective study of 230 patients with HF who underwent AF ablation, including 97 (42.2%) with HFrEF and 133 (57.8%) with HFpEF. Outcomes included adverse events, symptoms (Mayo AF Symptom Inventory [MAFSI]), New York Heart Association (NYHA) functional class, and freedom from recurrent atrial arrhythmia at 12 months. Overall, 150 of 230 patients had nonparoxysmal AF (62.8% HFpEF vs 63.0% HFrEF). Patients with HFpEF had a smaller mean left atrial diameter (4.4 ± 0.8 cm vs 4.7 ± 0.7 cm; P = .013) and were less likely to be taking a beta-blocker at baseline (72.9% vs 85.6%; P = .022). Median (Q1, Q3) procedure times (233 minutes [192, 290] vs 233.5 minutes [193.0, 297.5]; P = .780) and adverse events such as acute HF (3.8% vs 6.2%; P = .395) were similar between HFpEF and HFrEF patients. Freedom from recurrent atrial arrhythmia was not significantly different in HFpEF vs HFrEF patients (33.9% vs 32.6%; adjusted hazard ratio 1.47; 95% confidence interval 0.72-3.01), with similar improvements in NYHA functional class (-0.32 vs -0.19; P = .135) and MAFSI symptom severity (-0.23 vs -0.09; P = .116) after ablation. Catheter ablation of AF seems to have similar effectiveness in patients with HF, regardless of presence of systolic dysfunction. There were no significant differences in procedural characteristics, arrhythmia-free recurrence, or functional improvements between patients with HFpEF and those with HFrEF. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Patients With Undetermined Stroke Have Increased Atrial Fibrosis: A Cardiac Magnetic Resonance Imaging Study.

    PubMed

    Fonseca, Ana Catarina; Alves, Pedro; Inácio, Nuno; Marto, João Pedro; Viana-Baptista, Miguel; Pinho-E-Melo, Teresa; Ferro, José M; Almeida, Ana G

    2018-03-01

    Some patients with ischemic strokes that are currently classified as having an undetermined cause may have structural or functional changes of the left atrium (LA) and left atrial appendage, which increase their risk of thromboembolism. We compared the LA and left atrial appendage of patients with different ischemic stroke causes using cardiac magnetic resonance imaging. We prospectively included a consecutive sample of ischemic stroke patients. Patients with structural changes on echocardiography currently considered as causal for stroke in the Trial of ORG 10172 in Acute Stroke Treatment (TOAST) classification were excluded. A 3-T cardiac magnetic resonance imaging was performed. One hundred and eleven patients were evaluated. Patients with an undetermined cause had a higher percentage of LA fibrosis ( P =0.03) than patients with other stroke causes and lower, although not statistically significant, values of LA ejection fraction. Patients with atrial fibrillation and undetermined stroke cause showed a similar value of atrial fibrosis. The LA phenotype that was found in patients with undetermined cause supports the hypothesis that an atrial disease may be associated with stroke. © 2018 American Heart Association, Inc.

  10. Right atrial volume by cardiovascular magnetic resonance predicts mortality in patients with heart failure with reduced ejection fraction

    PubMed Central

    Ivanov, Alexander; Mohamed, Ambreen; Asfour, Ahmed; Ho, Jean; Khan, Saadat A.; Chen, Onn; Klem, Igor; Ramasubbu, Kumudha; Brener, Sorin J.; Heitner, John F.

    2017-01-01

    Background Right Atrial Volume Index (RAVI) measured by echocardiography is an independent predictor of morbidity in patients with heart failure (HF) with reduced ejection fraction (HFrEF). The aim of this study is to evaluate the predictive value of RAVI assessed by cardiac magnetic resonance (CMR) for all-cause mortality in patients with HFrEF and to assess its additive contribution to the validated Meta-Analysis Global Group in Chronic heart failure (MAGGIC) score. Methods and results We identified 243 patients (mean age 60 ± 15; 33% women) with left ventricular ejection fraction (LVEF) ≤ 35% measured by CMR. Right atrial volume was calculated based on area in two- and four -chamber views using validated equation, followed by indexing to body surface area. MAGGIC score was calculated using online calculator. During mean period of 2.4 years 33 patients (14%) died. The mean RAVI was 53 ± 26 ml/m2; significantly larger in patients with than without an event (78.7±29 ml/m2 vs. 48±22 ml/m2, p<0.001). RAVI (per ml/m2) was an independent predictor of mortality [HR = 1.03 (1.01–1.04), p = 0.001]. RAVI has a greater discriminatory ability than LVEF, left atrial volume index and right ventricular ejection fraction (RVEF) (C-statistic 0.8±0.08 vs 0.55±0.1, 0.62±0.11, 0.68±0.11, respectively, all p<0.02). The addition of RAVI to the MAGGIC score significantly improves risk stratification (integrated discrimination improvement 13%, and category-free net reclassification improvement 73%, both p<0.001). Conclusion RAVI by CMR is an independent predictor of mortality in patients with HFrEF. The addition of RAVI to MAGGIC score improves mortality risk stratification. PMID:28369148

  11. Influence of Genotype on Structural Atrial Abnormalities and Atrial Fibrillation or Flutter in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy.

    PubMed

    Bourfiss, Mimount; Te Riele, Anneline S J M; Mast, Thomas P; Cramer, Maarten J; VAN DER Heijden, Jeroen F; VAN Veen, Toon A B; Loh, Peter; Dooijes, Dennis; Hauer, Richard N W; Velthuis, Birgitta K

    2016-12-01

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is associated with desmosomal mutations. Although desmosomal disruption affects both ventricles and atria, little is known about atrial involvement in ARVD/C. To describe the extent and clinical significance of structural atrial involvement and atrial arrhythmias (AA) in ARVD/C stratified by genotype. We included 71 patients who met ARVD/C Task Force Criteria and underwent cardiac magnetic resonance (CMR) imaging and molecular genetic analysis. Indexed atrial end-diastolic volume and area-length-ejection-fraction (ALEF) were evaluated on CMR and compared to controls with idiopathic right ventricular outflow tract tachycardia (n = 40). The primary outcome was occurrence of AA (atrial fibrillation or atrial flutter) during follow-up, recorded by 12-lead ECG, Holter monitoring or implantable cardioverter defibrillator (ICD) interrogation. Patients harbored a desmosomal plakophilin-2 (PKP2) (n = 37) or nondesmosomal phospholamban (PLN) (n = 14) mutation. In 20 subjects, no pathogenic mutation was identified. Compared to controls, right atrial (RA) volumes were reduced in PKP2 (P = 0.002) and comparable in PLN (P = 0.441) mutation carriers. In patients with no mutation identified, RA (P = 0.011) and left atrial (P = 0.034) volumes were increased. Bi-atrial ALEF showed no significant difference between the groups. AA were experienced by 27% of patients and occurred equally among PKP2 (30%) and no mutation identified patients (30%), but less among PLN mutation carriers (14%). Genotype influences atrial volume and occurrence of AA in ARVD/C. While the incidence of AA is similar in PKP2 mutation carriers and patients with no mutation identified, PKP2 mutation carriers have significantly smaller atria. This suggests a different arrhythmogenic mechanism. © 2016 Wiley Periodicals, Inc.

  12. Fibroblast growth factor-21 is positively associated with atrial fibrosis in atrial fibrillation patients with rheumatic heart disease.

    PubMed

    Wang, Rui; Yi, Xin; Li, Xiaoyan; Jiang, Xuejun

    2015-01-01

    Fibroblast growth factor-21 (FGF-21) has been discovered as a strong hormone, plays an important role in lipid metabolism, glucose metabolism, associated with several diseases such as obesity, metabolic syndrome, diabetes mellitus, and cardiovascular events; however, no evidence is available concerning the relationship of FGF-21 and atrial fibrosis in patients with atrial fibrillation (AF) and rheumatic heart disease (RHD). Twenty-four rheumatic heart disease patients were divided into two groups, 12 cases with AF and 12 cases with sinus rhythm (SR). Clinical characteristics and blood samples were collected before surgery; right atrial appendage samples were taken in the surgery of valve replacement. HE staining was performed to determine cross-sectional area of atrial myocytes; Masson stained sections and mRNA levels of cardiac fibrosis biomarkers were used to evaluate the degree of cardiac fibrosis; the level of FGF-21 was evaluated via enzyme-linked immunosorbent assay (ELISA), immunohistochemistry, and real-time polymerase chain reaction (PCR). Compared with SR group, cross-sectional area of atrial myocytes and collagen volume fraction were significantly increased in the atrial tissue of AF group. The distribution of FGF-21 in the AF group was remarkably higher than SR group. In addition, plasma and mRNA levels of FGF-21 in atrial tissue of AF showed the same trend as the result of immunohistochemistry. Using linear correlation analysis, the expression level of FGF-21 was found to be positively related to the degree of atrial fibrosis. FGF-21 might involve in the development and maintenance of atrial fibrosis in atrial fibrillation with rheumatic heart disease, and FGF-21 could be used as a novel biomarker to evaluate myocardial fibrosis in the future.

  13. Atrial Fibrillation in Heart Failure With Preserved Ejection Fraction: Association With Exercise Capacity, Left Ventricular Filling Pressures, Natriuretic Peptides, and Left Atrial Volume.

    PubMed

    Lam, Carolyn S P; Rienstra, Michiel; Tay, Wan Ting; Liu, Licette C Y; Hummel, Yoran M; van der Meer, Peter; de Boer, Rudolf A; Van Gelder, Isabelle C; van Veldhuisen, Dirk J; Voors, Adriaan A; Hoendermis, Elke S

    2017-02-01

    This study sought to study the association of atrial fibrillation (AF) with exercise capacity, left ventricular filling pressure, natriuretic peptides, and left atrial size in heart failure with preserved ejection fraction (HFpEF). The diagnosis of HFpEF in patients with AF remains a challenge because both contribute to impaired exercise capacity, and increased natriuretic peptides and left atrial volume. We studied 94 patients with symptomatic heart failure and left ventricular ejection fractions ≥45% using treadmill cardiopulmonary exercise testing and right- and/or left-sided cardiac catheterization with simultaneous echocardiography. During catheterization, 62 patients were in sinus rhythm, and 32 patients had AF. There were no significant differences in age, sex, body size, comorbidities, or medications between groups; however, patients with AF had lower peak oxygen consumption (VO 2 ) compared with those with sinus rhythm (10.8 ± 3.1 ml/min/kg vs. 13.5 ± 3.8 ml/min/kg; p = 0.002). Median (25th to 75th percentile) N-terminal pro-B-type natriuretic peptide (NT-proBNP) was higher in AF versus sinus rhythm (1,689; 851 to 2,637 pg/ml vs. 490; 272 to 1,019 pg/ml; p < 0.0001). Left atrial volume index (LAVI) was higher in AF than sinus rhythm (57.8 ± 17.0 ml/m 2 vs. 42.5 ± 15.1 ml/m 2 ; p = 0.001). Invasive hemodynamics showed higher mean pulmonary capillary wedge pressure (PCWP) (19.9 ± 3.7 vs. 15.2 ± 6.8) in AF versus sinus rhythm (all p < 0.001), with a trend toward higher left ventricular end-diastolic pressure (17.7 ± 3.0 mm Hg vs. 15.7 ± 6.9 mm Hg; p = 0.06). After adjusting for clinical covariates and mean PCWP, AF remained associated with reduced peak VO 2 increased log NT-proBNP, and enlarged LAVI (all p ≤0.005). AF is independently associated with greater exertional intolerance, natriuretic peptide elevation, and left atrial remodeling in HFpEF. These data support the application of different thresholds of NT-proBNP and LAVI for the diagnosis of HFpEF in the presence of AF versus the absence of AF. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Usefulness of bedside tissue Doppler echocardiography and B-type natriuretic peptide (BNP) in differentiating congestive heart failure from noncardiac cause of acute dyspnea in elderly patients with a normal left ventricular ejection fraction and permanent, nonvalvular atrial fibrillation: insights from a prospective, monocenter study.

    PubMed

    Arques, Stephane; Roux, Emmanuel; Sbragia, Pascal; Pieri, Bertrand; Gelisse, Richard; Luccioni, Roger; Ambrosi, Pierre

    2007-05-01

    The incremental role of bedside tissue Doppler echocardiography and B-type natriuretic peptide (BNP) over the clinical judgment has been recently reported in the emergency diagnosis of congestive heart failure with a normal left ventricular ejection fraction (HFNEF). However, how well does this diagnostic strategy be applicable in the setting of atrial fibrillation is unknown. To investigate the usefulness of bedside tissue Doppler echocardiography and BNP in the emergency diagnosis of HFNEF in elderly patients with permanent, nonvalvular atrial fibrillation. Forty-one consecutive elderly patients with an ejection fraction > or =50% (mean age 84 years; 22 with HFNEF and 19 with noncardiac cause), hospitalized for acute dyspnea at rest, were prospectively enrolled; bedside septal E/Ea and BNP were obtained at admission. By multivariable logistic regression analysis including the clinical judgment of heart failure, E/Ea and BNP, E/Ea (P = 0.014) and BNP (P = 0.018) provided independent diagnostic information. Optimal cutoffs were 13 for E/Ea (area under the ROC curve of 0.846, P < 0.0001; sensitivity 81.8%, specificity 89.5%) and 253 pg/ml for BNP (area under the ROC curve of 0.928, P < 0.0001; sensitivity 86.4%, specificity 89.5%). The concordance between the clinical judgment and BNP concentration at the cutoff of 253 pg/ml correctly classified 24 of 25 patients; E/Ea at the cutoff of 13 correctly classified 14 of the 16 patients with discrepancy. Bedside tissue Doppler echocardiography and BNP provide useful additional diagnostic information over the clinical judgment for the emergency diagnosis of HFNEF in elderly patients with permanent, nonvalvular atrial fibrillation.

  15. The clinical benefit of cardiac resynchronization therapy optimization using a device-based hemodynamic sensor in a patient with dilated cardiomyopathy: a case report.

    PubMed

    Volpicelli, Mario; Covino, Gregorio; Capogrosso, Paolo

    2015-12-19

    Results on the evolution of the clinical status of patients undergoing cardiac resynchronization therapy with a defibrillator after automatic optimization of their cardiac resynchronization therapy are scarce. We observed a rapid and important change in the clinical status of our non-responding patient following activation of a sensor capable of weekly atrioventricular and interventricular delays' optimization. A 78-year-old Caucasian man presented with dilated cardiomyopathy, left bundle branch block, a left ventricular ejection fraction of 35 %, New York Heart Association class III/IV heart failure, and paroxysmal atrial fibrillation. Our patient was implanted with a cardiac resynchronization device with a defibrillator and the SonRtip atrial lead. Right ventricular and left ventricular leads were also implanted. Because of the recurrence of atrial fibrillation, the automatic optimization was set off at discharge. Consequently, the device did not optimize atrioventricular and interventricular delays (programming at discharge: 125 ms for the atrioventricular delay and 0 ms for the interventriculardelay). Our patient was treated with an anti-arrhythmic drug. Five months after implantation, his clinical status remained impaired (left ventricular ejection fraction = 30 %). The SonR signal amplitude had also decreased from 0.52 g to 0.29 g. Nevertheless, because our patient was no longer presenting with atrial fibrillation, the anti-arrhythmic treatment was stopped and the SonR optimization system was activated. After 2 months of automatic cardiac resynchronization therapy with defibrillator optimization, our patient's clinical status had significantly improved (left ventricular ejection fraction = 60 %, New York Heart Association class II) and the SonR signal amplitude had doubled shortly after the first weekly automatic optimization. In this non-responding patient, device-based automatic cardiac resynchronization therapy optimization was shown to significantly improve his clinical status.

  16. Cardiac Cycle Dependent Left Atrial Dynamics: Implications for Catheter Ablation of Atrial Fibrillation

    PubMed Central

    Patel, Amit R.; Fatemi, Omid; Norton, Patrick T.; West, J. Jason; Helms, Adam S.; Kramer, Christopher M.; Ferguson, John D.

    2008-01-01

    Background Left atrial volume (LAV) determines prognosis and response to therapy in atrial fibrillation. Integration of electro-anatomical maps with 3D-images rendered from CT and MRI is used to facilitate atrial fibrillation ablation. Objectives We measured LAV changes and regional motion during the cardiac cycle that might affect the accuracy of image integration and determined their relationship to standard LAV measurements. Methods MRI was performed in thirty patients with paroxysmal atrial fibrillation. Left atrial time-volume curves were generated and used to divide the left atrial function (LAEF) into pumping (PEF) and conduit (CEF) fractions and to determine the maximum LAV (LAMAX) and the pre-atrial contraction volume (PACV). LAV was measured using an MRI angiogram and traditional geometric models from echocardiography (area-length and ellipsoid). The in-plane displacement of the pulmonary veins, anterior left atrium, mitral annulus, and left atrial appendage was measured. Results LAMAX was 107±36ml and occurred at 42±5% of the RR interval. PACV was 86 ±34ml and occurred at 81±4% of the RR interval. LAEF was 45±10% and PEF was 31±10%. LAV measurements made from the MRI angiogram, area-length and ellipsoid models underestimated LAMAX by 21±25ml, 16±26ml, and 35±22ml, respectively. The anterior LA, mitral annulus, and left atrial appendage were significantly displaced during the cardiac cycle (8.8±2.0mm, 13.2±3.8mm, and 10.2±3.4mm, respectively); the pulmonary veins were not. Conclusions LAV changes significantly during the cardiac cycle and substantial regional variation in left atrial motion exists. Standard measurements of left atrial volume significantly underestimate LAMAX when compared to the gold standard measure of 3D-volumetrics. PMID:18486563

  17. Effect of left ventricular diastolic dysfunction on left atrial appendage function and thrombotic potential in nonvalvular atrial fibrillation.

    PubMed

    Demirçelik, Muhammed Bora; Çetin, Mustafa; Çiçekcioğlu, Hülya; Uçar, Özgül; Duran, Mustafa

    2014-05-01

    We aimed to investigate effects of left ventricular diastolic dysfunction on left atrial appendage functions, spontaneous echo contrast and thrombus formation in patients with nonvalvular atrial fibrillation. In 58 patients with chronic nonvalvular atrial fibrilation and preserved left ventricular systolic function, left atrial appendage functions, left atrial spontaneous echo contrast grading and left ventricular diastolic functions were evaluated using transthoracic and transoesophageal echocardiogram. Patients divided in two groups: Group D (n=30): Patients with diastolic dysfunction, Group N (n=28): Patients without diastolic dysfunction. Categorical variables in two groups were evaluated with Pearson's chi-square or Fisher's exact test. The significance of the lineer correlation between the degree of spontaneous echo contrast (SEC) and clinical measurements was evaluated with Spearman's correlation analysis. Peak pulmonary vein D velocity of the Group D was significantly higher than the Group N (p=0.006). However, left atrial appendage emptying velocity, left atrial appendage lateral wall velocity, peak pulmonary vein S, pulmonary vein S/D ratio were found to be significantly lower in Group D (p=0.028, p<0.001, p<0.001; p<0.001). Statistically significant negative correlation was found between SEC in left atrium and left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities respectively (r=-0.438, r=-0.328, r=-0.233, r=-0.447). Left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities were significantly lower in SEC 2-3-4 than SEC 1 (p=0.003, p=0.029, p<0.001, p=0.002). In patients with nonvalvular atrial fibrillation and preserved left ventricular ejection fraction, left atrial appendage functions are decreased in patients with left ventricular diastolic dysfunction. Left ventricular diastolic dysfunction may constitute a potential risk for formation of thrombus and stroke.

  18. Left atriotomy versus right atriotomy trans-septal approach for left atrial myxoma.

    PubMed

    Hatemi, A C; Gürsoy, M; Tongut, A; Kiliçkesmez, K; Karaoğlu, K; Küçükoğlu, S; Kansiz, E

    2010-01-01

    The biatrial approach has been the classic means of access for left atrial myxoma resection. Increased surgical experience led cardiac surgeons to favour the uniatrial approach to reduce incisions and achieve adequate exposure. In this study, two unilateral surgical approaches were compared in 18 consecutive left atrial myxoma cases. Patients were divided into two groups according to the surgical approach: left atriotomy (group 1, n = 9) and right atriotomy trans-septal approach (group 2, n = 9). Comparison criteria included pre- and post-operative functional capacity, cardiac rhythm, left ventricular ejection fraction, pulmonary artery pressure, left atrial dimensions, cardiopulmonary bypass time, aortic cross-clamp time, drainage over 48 h post-operatively, units of blood transfused, extubation time and length of stay in the intensive care unit and hospital. No significant between-group difference was observed in any criteria except aortic cross-clamp time, which was significantly longer in group 2 than in group 1. No recurrence of myxoma occurred in either group for the 15 patients followed up. Right atrial trans-septal incision appears to be as safe and effective as the left atriotomy approach for left atrial myxoma resection.

  19. Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size.

    PubMed

    Ikeda, Atsushi; Nakagawa, Hiroshi; Lambert, Hendrik; Shah, Dipen C; Fonck, Edouard; Yulzari, Aude; Sharma, Tushar; Pitha, Jan V; Lazzara, Ralph; Jackman, Warren M

    2014-12-01

    Electrode-tissue contact force (CF) is believed to be a major factor in radiofrequency lesion size. The purpose of this study was to determine, in the beating canine heart, the relationship between CF and radiofrequency lesion size and the accuracy of predicting CF and lesion size by measuring electrogram amplitude, impedance, and electrode temperature. Eight dogs were studied closed chest. Using a 7F catheter with a 3.5 mm irrigated electrode and CF sensor (TactiCath, St. Jude Medical), radiofrequency applications were delivered to 3 separate sites in the right ventricle (30 W, 60 seconds, 17 mL/min irrigation) and 3 sites in the left ventricle (40 W, 60 seconds, 30 mL/min irrigation) at (1) low CF (median 8 g); (2) moderate CF (median 21 g); and (3) high CF (median 60 g). Dogs were euthanized and lesion size was measured. At constant radiofrequency and time, lesion size increased significantly with increasing CF (P<0.01). The incidence of a steam pop increased with both increasing CF and higher power. Peak electrode temperature correlated poorly with lesion size. The decrease in impedance during the radiofrequency application correlated well with lesion size for lesions in the left ventricle but less well for lesions in the right ventricle. There was a poor relationship between CF and the amplitude of the bipolar or unipolar ventricular electrogram, unipolar injury current, and impedance. Radiofrequencylesion size and the incidence of steam pop increase strikingly with increasing CF. Electrogram parameters and initial impedance are poor predictors of CF for radiofrequency ablation. © 2014 American Heart Association, Inc.

  20. Prevention of adenosine A2A receptor activation diminishes beat-to-beat alternation in human atrial myocytes.

    PubMed

    Molina, Cristina E; Llach, Anna; Herraiz-Martínez, Adela; Tarifa, Carmen; Barriga, Montserrat; Wiegerinck, Rob F; Fernandes, Jacqueline; Cabello, Nuria; Vallmitjana, Alex; Benitéz, Raúl; Montiel, José; Cinca, Juan; Hove-Madsen, Leif

    2016-01-01

    Atrial fibrillation (AF) has been associated with increased spontaneous calcium release from the sarcoplasmic reticulum and linked to increased adenosine A2A receptor (A2AR) expression and activation. Here we tested whether this may favor atrial arrhythmogenesis by promoting beat-to-beat alternation and irregularity. Patch-clamp and confocal calcium imaging was used to measure the beat-to-beat response of the calcium current and transient in human atrial myocytes. Responses were classified as uniform, alternating or irregular and stimulation of Gs-protein coupled receptors decreased the frequency where a uniform response could be maintained from 1.0 ± 0.1 to 0.6 ± 0.1 Hz; p < 0.01 for beta-adrenergic receptors and from 1.4 ± 0.1 to 0.5 ± 0.1 Hz; p < 0.05 for A2ARs. The latter was linked to increased spontaneous calcium release and after-depolarizations. Moreover, A2AR activation increased the fraction of non-uniformly responding cells in HL-1 myocyte cultures from 19 ± 3 to 51 ± 9 %; p < 0.02, and electrical mapping in perfused porcine atria revealed that adenosine induced electrical alternans at longer cycle lengths, doubled the fraction of electrodes showing alternation, and increased the amplitude of alternations. Importantly, protein kinase A inhibition increased the highest frequency where uniform responses could be maintained from 0.84 ± 0.12 to 1.86 ± 0.11 Hz; p < 0.001 and prevention of A2AR-activation with exogenous adenosine deaminase selectively increased the threshold from 0.8 ± 0.1 to 1.2 ± 0.1 Hz; p = 0.001 in myocytes from patients with AF. In conclusion, A2AR-activation promotes beat-to-beat irregularities in the calcium transient in human atrial myocytes, and prevention of A2AR activation may be a novel means to maintain uniform beat-to-beat responses at higher beating frequencies in patients with atrial fibrillation.

  1. Does preoperative atrial fibrillation influence early and late outcomes of coronary artery bypass grafting?

    PubMed

    Ngaage, Dumbor L; Schaff, Hartzell V; Mullany, Charles J; Sundt, Thoralf M; Dearani, Joseph A; Barnes, Sunni; Daly, Richard C; Orszulak, Thomas A

    2007-01-01

    The study objective was to describe the independent effect of preoperative atrial fibrillation on the outcome of coronary artery bypass grafting, including the causes of death (cardiac vs noncardiac). We analyzed the outcome of patients with preoperative atrial fibrillation who underwent on-pump coronary artery bypass grafting between 1993 and 2002 and compared them with matched controls in sinus rhythm; matching variables were age, gender, ejection fraction, and numbers of diseased coronary arteries and distal anastomoses. Direct patient follow-up focused on late complications and reinterventions, and we investigated causes for all deaths. Operative mortality (1.6% vs 1.9%, P = .79) was similar in patients with preoperative atrial fibrillation (n = 257) compared with patients in sinus rhythm (n = 269). The patients with atrial fibrillation had longer hospital stays (9 +/- 6 days vs 8 +/- 6 days, P = .0008) and a trend to more frequent early readmissions (13% vs 9%, P = .08). During follow-up (median 6.7 years, maximum 12 years), late hospital admission was more frequent in patients with atrial fibrillation (59% vs 31%, P < .0001). Risk of late mortality (all causes) in patients with atrial fibrillation was increased by 40% compared with patients in sinus rhythm (P = 0.02), and the late cardiac death rate in the atrial fibrillation group was 2.8 times that of the sinus rhythm group (P = .0004). Major adverse cardiac events occurred in 70% of patients with preoperative atrial fibrillation compared with 52% of patients in preoperative sinus rhythm (P < .0001). Subsequent rhythm-related intervention, including pacemaker implantations, was more common in the atrial fibrillation group (relative risk = 2.1, P = .0027). Uncorrected preoperative atrial fibrillation in patients undergoing coronary artery bypass grafting is associated with increased late cardiac morbidity and mortality and poor long-term survival. These data support consideration of atrial fibrillation surgery at the time of coronary artery bypass grafting.

  2. Assessment of ventricular and left atrial mechanical functions, atrial electromechanical delay and P wave dispersion in patients with scleroderma.

    PubMed

    Aktoz, Meryem; Yilmaztepe, Mustafa; Tatli, Ersan; Turan, Fatma Nesrin; Umit, Elif G; Altun, Armagan

    2011-01-01

    The aim of this study was to investigate ventricular functions and left atrial (LA) mechanical functions, atrial electromechanical coupling, and P wave dispersion in scleroderma patients. Twenty-six patients with scleroderma and twenty-four controls were included. Left and right ventricular (LV and RV) functions were evaluated using conventional echocardiography and tissue Doppler imaging (TDI). LA volumes were measured using the biplane area- -length method and LA mechanical function parameters were calculated. Inter-intraatrial electromechanical delays were measured by TDI. P wave dispersion was calculated by 12-lead electrocardiograms. LV myocardial performance indices (MPI) and RV MPI were higher in patients with scleroderma (p = 0.000, p = 0.000, respectively) while LA passive emptying fraction was decreased and LA active emptying fraction was increased (p = 0.051, p = 0.000, respectively). P wave dispersion and inter-intraatrial electromechanical delay were significantly higher in patients with scleroderma (25 [10-60] vs 20 [0-30], p = 0.000, 16.50 [7.28-26.38] vs 9.44 [3.79-15.78] and 11.33 [4.88-16.06] vs 4.00 [0-12.90], p < 0.05, respectively). Interatrial electromechanical delay was negatively correlated with LV E wave, (p = 0.018). LV E wave was demonstrated to be a factor independent of the interatrial electromechanical delay (R² = = 0.270, b = -0.52, p = 0.013). This study showed that in scleroderma patients, global functions of LV, RV and mechanical functions of LA were impaired, intra-interatrial electromechanical delays were prolonged and P wave dispersion was higher. LV E wave was demonstrated to be a factor that is independent of the interatrial electromechanical delay. Reduced LV E wave may also give additional information on the process of risk stratification of atrial fibrillation.

  3. Inhibition of sarcoplasmic reticulum Ca(2+)-ATPase decreases atrioventricular node-paced heart rate in rabbits.

    PubMed

    Cheng, Hongwei; Smith, Godfrey L; Orchard, Clive H; Hancox, Jules C; Burton, Francis L

    2012-10-01

    Recent data indicate that Ca(2+) cycling in isolated atrioventricular node (AVN) cells contributes to setting spontaneous rate. The aim of the present study was to extend this observation to the intact AVN in situ, by evaluating the effects of inhibiting sarcoplasmic reticulum Ca(2+) uptake with cyclopiazonic acid (CPA) on intact AVN spontaneous activity and its response to isoprenaline. A model of the AVN-paced heart was produced to investigate intact AVN automaticity, by surgical ablation of the sino-atrial node (SAN) in the rabbit Langendorff-perfused heart. Electrograms were recorded from a site close to the AVN (triangle of Koch), an atrial site above the AVN, the left atrium and right ventricle, enabling AVN pacing of the preparation to be confirmed. Before SAN ablation, the heart rate was 166.8 ± 5.4 beats min(-1). Ablation of the SAN was clearly indicated by a sudden and significant decrease of heart rate to 108.6 ± 9.6 beats min(-1) (P < 0.01, n = 10). Isoprenaline (100 nm) increased AVN rate to 187.8 ± 12.0 beats min(-1) after 1 min of application (P < 0.01, n = 10). Cyclopiazonic acid (10 and 30 μm) decreased AVN rate to 81.6 ± 4.8 (n = 9) and 77.4 ± 6.0 beats min(-1) (n = 7), respectively [P < 0.05, 10 or 30 μm CPA versus control (n = 10)] and also reduced the AVN rate increase in response to isoprenaline from 78.8 ± 10.0 to 46.8 ± 6.8 and 26.7 ± 5.3%, respectively (P < 0.01). These inhibitory effects of CPA on the intact AVN rate and its response to isoprenaline indicate that Ca(2+) cycling is important to the intact AVN spontaneous activity and its acceleration during sympathetic stimulation.

  4. Atrioventricular node functional remodeling induced by atrial fibrillation.

    PubMed

    Zhang, Youhua; Mazgalev, Todor N

    2012-09-01

    The atrioventricular node (AVN) plays a vital role in determining the ventricular rate during atrial fibrillation (AF). AF results in profound electrophysiological and structural remodeling in the atria as well as the sinus node. However, it is unknown whether AVN undergoes remodeling during AF. To determine whether AVN undergoes functional remodeling during AF. AVN conduction properties were studied in vitro in 9 rabbits with AF and 10 normal controls. A previously validated index of AVN dual-pathway electrophysiology, His-electrogram alternans, was used to monitor fast-pathway or slow-pathway (SP) AVN conduction in these experiments. AVN conduction properties were further studied in vivo in 7 dogs with chronic AF and 8 controls. Compared with the control rabbits, the rabbits with AF had a longer AVN conduction time (83 ± 16 ms vs 68 ± 7 ms; P <.01), longer AVN effective refractory period (141 ± 27 ms vs 100 ± 9 ms; P <.01), an earlier transition from fast-pathway to SP conduction (at a longer prematurity, 249 ± 60 ms vs 171 ± 24 ms; P <.01), and a slower ventricular rate during simulated AF (RR interval 249 ± 42 ms vs 202 ± 12 ms; P <.01). Notably, a larger proportion of conducted beats utilized the SP in AF preparations (92% ± 12% vs 63% ± 32%; P <.05). Long-term AF in dogs resulted in a longer atrioventricular conduction time and AVN effective refractory period and a slower ventricular rate during AF compared with the controls. Pronounced AVN functional electrophysiological remodeling occurs after long-term AF, which could lead to a spontaneous slowing of the ventricular rate. Furthermore, the SP dominance during AF underscores the effectiveness of its modification by ablation for ventricular rate control during AF. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation.

    PubMed

    Malcolme-Lawes, Louisa C; Lim, Phang Boon; Koa-Wing, Michael; Whinnett, Zachary I; Jamil-Copley, Shahnaz; Hayat, Sajad; Francis, Darrel P; Kojodjojo, Pipin; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa

    2013-01-01

    Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P < 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P < 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on outcomes from AF ablation procedures.

  6. ABO blood groups: A risk factor for left atrial and left atrial appendage thrombogenic milieu in patients with non-valvular atrial fibrillation.

    PubMed

    Fu, Yuan; Li, Kuibao; Yang, Xinchun

    2017-08-01

    Previous studies have identified ABO blood groups as predictors of thromboembolic diseases. In patients with atrial fibrillation (AF), however, potential association between ABO blood groups and the risk of left atrial (LA) and/or left atrial appendage (LAA) thrombogenic milieu (TM) has not been established. This is a retrospective case-control study that included 125 consecutive patients with non-valvular atrial fibrillation (NVAF) plus TM, as evidenced by transesophageal echocardiography (TEE) during a period from1 January 2010 to 31 December 2016. The controls were selected randomly from 1072 NVAF without TM at a 1:2 ratio. Potential association between ABO blood groups and TM was analyzed using multivariate logistic regression analysis. The risk of TM was higher in patients with blood group A (33.6% vs. 20.2% in non-A blood groups, P=0.005). After adjusting for age, sex, oral anticoagulant use, AF type and duration, and relevant functional measures (e.g., NT-pro BNP level, left atrium diameter, and left ventricular ejection fraction), blood group A remained associated with an increased risk of TM (OR=2.99, 95% CI 1.4-6.388, P=0.005). Blood group A is an independent risk factor for TM in NVAF patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Plasma Biomarkers Reflecting Profibrotic Processes in Heart Failure With a Preserved Ejection Fraction

    PubMed Central

    Zile, Michael R.; Jhund, Pardeep S.; Baicu, Catalin F.; Claggett, Brian L.; Pieske, Burkert; Voors, Adriaan A.; Prescott, Margaret F.; Shi, Victor; Lefkowitz, Martin; McMurray, John J.V.; Solomon, Scott D.

    2017-01-01

    Background Heart failure with preserved ejection fraction is a clinical syndrome that has been associated with changes in the extracellular matrix. The purpose of this study was to determine whether profibrotic biomarkers accurately reflect the presence and severity of disease and underlying pathophysiology and modify response to therapy in patients with heart failure with preserved ejection fraction. Methods and Results Four biomarkers, soluble form of ST2 (an interleukin-1 receptor family member), galectin-3, matrix metalloproteinase-2, and collagen III N-terminal propeptide were measured in the Prospective Comparison of ARNI With ARB on Management of Heart Failure With Preserved Ejection Fraction (PARAMOUNT) trial at baseline, 12 and 36 weeks after randomization to valsartan or LCZ696. We examined the relationship between baseline biomarkers, demographic and echocardiographic characteristics, change in primary (change in N-terminal pro B-type natriuretic peptide) and secondary (change in left atrial volume) end points. The median (interquartile range) value for soluble form of ST2 (33 [24.6–48.1] ng/mL) and galectin 3 (17.8 [14.1–22.8] ng/mL) were higher, and for matrix metalloproteinase-2 (188 [155.5–230.6] ng/mL) lower, than in previously published referent controls; collagen III N-terminal propeptide (5.6 [4.3–6.9] ng/mL) was similar to referent control values. All 4 biomarkers correlated with severity of disease as indicated by N-terminal pro B-type natriuretic peptide, E/E′, and left atrial volume. Baseline biomarkers did not modify the response to LCZ696 for lowering N-terminal pro B-type natriuretic peptide; however, left atrial volume reduction varied by baseline level of soluble form of ST2 and galectin 3; patients with values less than the observed median (<33 ng/mL soluble form of ST2 and <17.8 ng/mL galectin 3) had reduction in left atrial volume, those above median did not. Although LCZ696 reduced N-terminal pro B-type natriuretic peptide, levels of the other 4 biomarkers were not affected over time. Conclusions In patients with heart failure with preserved ejection fraction, biomarkers that reflect collagen homeostasis correlated with the presence and severity of disease and underlying pathophysiology, and may modify the structural response to treatment. PMID:26754625

  8. Plasma Biomarkers Reflecting Profibrotic Processes in Heart Failure With a Preserved Ejection Fraction: Data From the Prospective Comparison of ARNI With ARB on Management of Heart Failure With Preserved Ejection Fraction Study.

    PubMed

    Zile, Michael R; Jhund, Pardeep S; Baicu, Catalin F; Claggett, Brian L; Pieske, Burkert; Voors, Adriaan A; Prescott, Margaret F; Shi, Victor; Lefkowitz, Martin; McMurray, John J V; Solomon, Scott D

    2016-01-01

    Heart failure with preserved ejection fraction is a clinical syndrome that has been associated with changes in the extracellular matrix. The purpose of this study was to determine whether profibrotic biomarkers accurately reflect the presence and severity of disease and underlying pathophysiology and modify response to therapy in patients with heart failure with preserved ejection fraction. Four biomarkers, soluble form of ST2 (an interleukin-1 receptor family member), galectin-3, matrix metalloproteinase-2, and collagen III N-terminal propeptide were measured in the Prospective Comparison of ARNI With ARB on Management of Heart Failure With Preserved Ejection Fraction (PARAMOUNT) trial at baseline, 12 and 36 weeks after randomization to valsartan or LCZ696. We examined the relationship between baseline biomarkers, demographic and echocardiographic characteristics, change in primary (change in N-terminal pro B-type natriuretic peptide) and secondary (change in left atrial volume) end points. The median (interquartile range) value for soluble form of ST2 (33 [24.6-48.1] ng/mL) and galectin 3 (17.8 [14.1-22.8] ng/mL) were higher, and for matrix metalloproteinase-2 (188 [155.5-230.6] ng/mL) lower, than in previously published referent controls; collagen III N-terminal propeptide (5.6 [4.3-6.9] ng/mL) was similar to referent control values. All 4 biomarkers correlated with severity of disease as indicated by N-terminal pro B-type natriuretic peptide, E/E', and left atrial volume. Baseline biomarkers did not modify the response to LCZ696 for lowering N-terminal pro B-type natriuretic peptide; however, left atrial volume reduction varied by baseline level of soluble form of ST2 and galectin 3; patients with values less than the observed median (<33 ng/mL soluble form of ST2 and <17.8 ng/mL galectin 3) had reduction in left atrial volume, those above median did not. Although LCZ696 reduced N-terminal pro B-type natriuretic peptide, levels of the other 4 biomarkers were not affected over time. In patients with heart failure with preserved ejection fraction, biomarkers that reflect collagen homeostasis correlated with the presence and severity of disease and underlying pathophysiology, and may modify the structural response to treatment. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00887588. © 2016 American Heart Association, Inc.

  9. Usefulness of radionuclide angiocardiography in predicting stenotic mitral orifice area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burns, R.J.; Armitage, D.L.; Fountas, P.N.

    1986-12-01

    Fifteen patients with pure mitral stenosis (MS) underwent high-temporal-resolution radionuclide angiocardiography for calculation of the ratio of peak left ventricular (LV) filling rate divided by mean LV filling rate (filling ratio). Whereas LV filling normally occurs in 3 phases, in MS it is more uniform. Thus, in 13 patients the filling ratio was below the normal range of 2.21 to 2.88 (p less than 0.001). In 11 patients in atrial fibrillation, filling ratio divided by mean cardiac cycle length and by LV ejection fraction provided good correlation (r = 0.85) with modified Gorlin formula derived mitral area and excellent correlationmore » with echocardiographic mitral area (r = 0.95). Significant MS can be detected using radionuclide angiocardiography to calculate filling ratio. In the absence of the confounding influence of atrial systole calculation of 0.14 (filling ratio divided by cardiac cycle length divided by LV ejection fraction) + 0.40 cm2 enables accurate prediction of mitral area (+/- 4%). Our data support the contention that the modified Gorlin formula, based on steady-state hemodynamics, provides less certain estimates of mitral area for patients with MS and atrial fibrillation, in whom echocardiography and radionuclide angiocardiography may be more accurate.« less

  10. Hypertension is associated with preamyloid oligomers in human atrium: a missing link in atrial pathophysiology?

    PubMed

    Sidorova, Tatiana N; Mace, Lisa C; Wells, K Sam; Yermalitskaya, Liudmila V; Su, Pei-Fang; Shyr, Yu; Atkinson, James B; Fogo, Agnes B; Prinsen, Joseph K; Byrne, John G; Petracek, Michael R; Greelish, James P; Hoff, Steven J; Ball, Stephen K; Glabe, Charles G; Brown, Nancy J; Barnett, Joey V; Murray, Katherine T

    2014-12-02

    Increasing evidence indicates that proteotoxicity plays a pathophysiologic role in experimental and human cardiomyopathy. In organ-specific amyloidoses, soluble protein oligomers are the primary cytotoxic species in the process of protein aggregation. While isolated atrial amyloidosis can develop with aging, the presence of preamyloid oligomers (PAOs) in atrial tissue has not been previously investigated. Atrial samples were collected during elective cardiac surgery in patients without a history of atrial arrhythmias, congestive heart failure, cardiomyopathy, or amyloidosis. Immunohistochemistry was performed for PAOs using a conformation-specific antibody, as well as for candidate proteins identified previously in isolated atrial amyloidosis. Using a myocardium-specific marker, the fraction of myocardium colocalizing with PAOs (PAO burden) was quantified (green/red ratio). Atrial samples were obtained from 92 patients, with a mean age of 61.7±13.8 years. Most patients (62%) were male, 23% had diabetes, 72% had hypertension, and 42% had coronary artery disease. A majority (n=62) underwent aortic valve replacement, with fewer undergoing coronary artery bypass grafting (n=34) or mitral valve replacement/repair (n=24). Immunostaining detected intracellular PAOs in a majority of atrial samples, with a heterogeneous distribution throughout the myocardium. Mean green/red ratio value for the samples was 0.11±0.1 (range 0.03 to 0.77), with a value ≥0.05 in 74 patients. Atrial natriuretic peptide colocalized with PAOs in myocardium, whereas transthyretin was located in the interstitium. Adjusting for multiple covariates, PAO burden was independently associated with the presence of hypertension. PAOs are frequently detected in human atrium, where their presence is associated with clinical hypertension. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  11. Atrial fibrillation in heart failure with preserved ejection fraction: Insights into mechanisms and therapeutics.

    PubMed

    Patel, Ravi B; Vaduganathan, Muthiah; Shah, Sanjiv J; Butler, Javed

    2017-08-01

    Atrial fibrillation (AF) and heart failure (HF) often coexist, and the outcomes of patients who have both AF and HF are considerably worse than those with either condition in isolation. Heart failure with preserved ejection fraction (HFpEF) is a heterogeneous clinical entity and accounts for approximately one-half of current HF. At least one-third of patients with HFpEF are burdened by comorbid AF. The current understanding of the relationship between AF and HFpEF is limited, but the clinical implications are potentially important. In this review, we explore 1) the pathogenesis that drives AF and HFpEF to coexist; 2) pharmacologic therapies that may attenuate the impact of AF in HFpEF; and 3) future directions in the management of this complex syndrome. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Sleep Apnea and Left Atrial Phasic Function in Heart Failure With Reduced Ejection Fraction.

    PubMed

    Haruki, Nobuhiko; Tsang, Wendy; Thavendiranathan, Paaladinesh; Woo, Anna; Tomlinson, George; Logan, Alexander G; Bradley, T Douglas; Floras, John S

    2016-12-01

    The study aim was to determine whether phasic left atrial (LA) function of patients with heart failure with reduced ejection fraction differs between those with obstructive sleep apnea (OSA) and central sleep apnea (CSA). Participation in the Adaptive Servo Ventilation for Therapy of Sleep Apnea in Heart Failure (ADVENT-HF) trial requires 2-dimensional echocardiographic documentation of left ventricular ejection fraction ≤ 45% and a polysomnographic apnea hypopnea index (AHI) ≥ 15 events per hour. Of initial enrollees, we identified 132 patients in sinus rhythm (82 with predominantly OSA and 50 with CSA). To determine LA reservoir (expansion index; EI), conduit (passive emptying index; PEI), and booster function (active emptying index), we blindly quantified maximum and minimum LA volume and LA volume before atrial contraction. Each of EI (P = 0.004), PEI (P < 0.001), and active emptying index (P = 0.045) was less in participants with CSA compared with those with OSA, whereas average left ventricular ejection fraction and LA and left ventricular volumes were similar. Multivariable analysis identified an independent relationship between central AHI and LA EI (P = 0.040) and PEI (P = 0.005). In contrast, the obstructive AHI was unrelated to any LA phasic index, and slopes relating central AHI to EI and PEI differed significantly from corresponding relationships with obstructive AHI (P = 0.018; P = 0.006). In these ADVENT-HF patients with heart failure with reduced ejection fraction, all 3 components of LA phasic function (reservoir, conduit, and contractile) were significantly reduced in those with CSA compared with participants with OSA. The severity of CSA, but not OSA associated inversely and independently with LA reservoir and conduit function. Impaired LA phasic function might be consequent to or could exacerbate CSA. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  13. The effect of surgical treatment for secundum atrial septal defect in patients more than 30 years old.

    PubMed

    Erkut, Bilgehan; Becit, Necip; Unlu, Yahya; Ceviz, Munacettin; Kocogullari, Cevdet Ugur; Ates, Azman; Karapolat, Bekir Sami; Kaygin, Mehmet Ali; Kocak, Hikmet

    2007-01-01

    We prospectively examined whether surgical treatment of secundum atrial septal defects in patients 30 years old improves their early- and mid-term clinical outcomes. Our clinical experience is reviewed to assess the importance of surgical management in elderly patients with atrial septal defect. We analyzed 41 patients older than 30 years of age who underwent surgical correction of a secundum atrial septal defect. To evaluate the effects of surgical treatment, we compared functional capacity, diuretic administration, rhythm status, and echocardiographic parameters of all patients before and after the operation. The median follow-up period was 4.2 years (range, 6 months-7 years). There were no operative deaths. Functional class in most of the patients improved after operation. Two patients reverted to normal sinus rhythm after the operation. There was only one new atrial fibrilation among patients in the postoperative term. Right atrial and right ventricular dimensions and pulmonary artery pressures were significantly decreased, and ejection fractions were significantly increased after the operation. The need for diuretic treatment was decreased after surgical repair. No residual intracardiac shunts were identified during follow-up. There were no cerebrovascular thromboembolic accidents in the early postoperative period. Surgical closure of atrial septal defects in patients over 30 years old can improve their clinical status and prevent right ventricular dilatation and insufficiency. The operation must be performed as soon as possible, even if the symptoms or the hemodynamic impact seem to be minimal.

  14. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    PubMed

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was <0.35 mV-mV, then the detected rhythm was considered noise due to a lead failure. The first ICD-detected episode of lead failure and inappropriate detection from 24 ICD patients with a pace/sense lead failure and all ventricular arrhythmias from 56 ICD patients without a lead failure were selected. The stored data were analyzed to determine the sensitivity and specificity of the algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  15. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study.

    PubMed

    Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio

    2018-06-01

    To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.

  16. Are left ventricular ejection fraction and left atrial diameter related to atrial fibrillation recurrence after catheter ablation?

    PubMed Central

    Jin, Xiao; Pan, Jianke; Wu, Huanlin; Xu, Danping

    2018-01-01

    Abstract Atrial fibrillation (AF), the most common form of arrhythmia, is associated with the prevalence of many common cardiovascular and cerebrovascular diseases. Catheter ablation is considered the first-line therapy for AF; however, AF recurrence is very common after catheter ablation. Studies have been performed to analyze the factors associated with AF recurrence, but none have reached a consistent conclusion on whether left ventricular ejection fraction (LVEF) and left atrial diameter (LA diameter) affect AF recurrence after catheter ablation. The databases PubMed, Embase, and the Cochrane Library were used to search for relevant studies up to September 2017. RevMan 5.3.5 software provided by the Cochrane Collaboration Network was used to conduct this meta-analysis. Thirteen studies involving 2825 patients were included in this meta-analysis. Overall, the results revealed that elevated LA diameter values were significantly associated with AF recurrence in patients after catheter ablation (MD = 2.19, 95% CI: 1.63–2.75, P < .001), while baseline LVEF levels were not significantly positively associated with AF recurrence in patients after catheter ablation (MD = −0.91, 95% CI: −1.18 to 1.67, P = .14). Overall, elevated LA diameter may be associated with AF recurrence after catheter ablation; however, there was no direct relationship between LVEF values and AF recurrence after catheter ablation when baseline LVEF values are normal or mildly decreased. Besides, because of publication bias, further studies should be performed to explore the mechanisms underlying AF recurrence. PMID:29768386

  17. Altered transient outward current in human atrial myocytes of patients with reduced left ventricular function.

    PubMed

    Schreieck, J; Wang, Y; Overbeck, M; Schömig, A; Schmitt, C

    2000-02-01

    Electrophysiologic remodeling is involved in the self-perpetuation of atrial fibrillation. To define whether differences in atrial electrophysiology already are present in patients with increased susceptibility for atrial fibrillation, we compared patients in sinus rhythm with and without heart failure. Atrial specimens were obtained from patients with reduced left ventricular ejection fraction (LVEF; n = 10) and normal LVEF (n = 16) who were undergoing aortocoronary bypass surgery and from donor hearts (n = 4). Enzymatically isolated atrial myocytes were investigated by whole cell, patch clamp techniques. Total outward current was significantly larger in myocytes of hearts with low LVEF than normal LVEF (19.4 +/- 1.3 vs 15.1 +/- 1.2 pA/pF at pulses to +60 mV, respectively). Analysis of inactivation time courses of different outward current components revealed that the observed current difference is due to the transient calcium-independent outward current I(to1) which is twice as large in the low LVEF group than in the normal LVEF group (9.4 +/- 0.9 vs 4.7 +/- 0.4 pA/pF at pulses to +60 mV, respectively). I(to1) recovery from inactivation was significantly more rapid in myocytes of hearts with low LVEF, and action potential plateau in these cells was significantly shorter. The results of I(to1) and action potential measurements in atrial myocytes of donor hearts were very similar to the results of patients with preserved heart function. I(to1) in human atrial myocytes of patients with reduced LVEF has an increased density and altered kinetics in sinus rhythm. These differences in outward current may explain the reduced plateau phase of action potentials.

  18. [Left atrial function and left atrial appendage flow velocity in hypertrophic cardiomyopathy: comparison of patients with and without paroxysmal atrial fibrillation].

    PubMed

    Akasaka, K; Kawashima, E; Shiokoshi, T; Ishii, Y; Hasebe, N; Kikuchi, K

    1998-07-01

    The involvement of left atrial (LA) appendage flow velocity in reduced left atrial function was investigated in 24 patients with hypertrophic cardiomyopathy, who retained sinus rhythm at the examination. Patients were divided into 11 with a history of paroxysmal atrial fibrillation [PAf(+)] and 13 without such history [PAf(-)]. Transthoracic echocardiography was performed to evaluate LA fractional shortening (LA%FS) and mean velocity of circumferential LA fiber shortening (LAmVcf), as contractile functions of the left atrium at the phase of active atrial contraction. Transesophageal echocardiographic Doppler examination was performed in all patients to measure the LA appendage velocity. In all patients, significant positive correlations were observed between the LA appendage velocity and LA%FS (r = 0.50, p < 0.05) or LAmVcf (r = 0.82, p < 0.001). LAmVcf and LA appendage velocity in patients with paroxysmal fibrillation were significantly lower than in those without (0.84 +/- 0.15 vs 1.28 +/- 0.37 circ/sec, 44 +/- 12 vs 65 +/- 20 cm/sec, both p < 0.01), whereas LA diameter was greater in the former compared to the latter (45 +/- 5 vs 38 +/- 5 mm, p < 0.01). LAmVcf and LA appendage velocity were low in four patients with cerebral infarction or transient cerebral ischemic attack (LAmVcf < 1.0 circ/sec, LA appendage velocity < or = 40 cm/sec). Importantly, all these patients had a history of paroxysmal fibrillation. These results indicate that there is a close relationship between LA appendage velocity and LA contractile function in patients with hypertrophic cardiomyopathy with paroxysmal atrial fibrilation, and these patients have potential risk of cerebral infarction.

  19. The effects of rhythm control strategies versus rate control strategies for atrial fibrillation and atrial flutter: A systematic review with meta-analysis and Trial Sequential Analysis

    PubMed Central

    Gluud, Christian; Jakobsen, Janus C.

    2017-01-01

    Background Atrial fibrillation and atrial flutter may be managed by either a rhythm control strategy or a rate control strategy but the evidence on the clinical effects of these two intervention strategies is unclear. Our objective was to assess the beneficial and harmful effects of rhythm control strategies versus rate control strategies for atrial fibrillation and atrial flutter. Methods We searched CENTRAL, MEDLINE, Embase, LILACS, Web of Science, BIOSIS, Google Scholar, clinicaltrials.gov, TRIP, EU-CTR, Chi-CTR, and ICTRP for eligible trials comparing any rhythm control strategy with any rate control strategy in patients with atrial fibrillation or atrial flutter published before November 2016. Our primary outcomes were all-cause mortality, serious adverse events, and quality of life. Our secondary outcomes were stroke and ejection fraction. We performed both random-effects and fixed-effect meta-analysis and chose the most conservative result as our primary result. We used Trial Sequential Analysis (TSA) to control for random errors. Statistical heterogeneity was assessed by visual inspection of forest plots and by calculating inconsistency (I2) for traditional meta-analyses and diversity (D2) for TSA. Sensitivity analyses and subgroup analyses were conducted to explore the reasons for substantial statistical heterogeneity. We assessed the risk of publication bias in meta-analyses consisting of 10 trials or more with tests for funnel plot asymmetry. We used GRADE to assess the quality of the body of evidence. Results 25 randomized clinical trials (n = 9354 participants) were included, all of which were at high risk of bias. Meta-analysis showed that rhythm control strategies versus rate control strategies significantly increased the risk of a serious adverse event (risk ratio (RR), 1.10; 95% confidence interval (CI), 1.02 to 1.18; P = 0.02; I2 = 12% (95% CI 0.00 to 0.32); 21 trials), but TSA did not confirm this result (TSA-adjusted CI 0.99 to 1.22). The increased risk of a serious adverse event did not seem to be caused by any single component of the composite outcome. Meta-analysis showed that rhythm control strategies versus rate control strategies were associated with better SF-36 physical component score (mean difference (MD), 6.93 points; 95% CI, 2.25 to 11.61; P = 0.004; I2 = 95% (95% CI 0.94 to 0.96); 8 trials) and ejection fraction (MD, 4.20%; 95% CI, 0.54 to 7.87; P = 0.02; I2 = 79% (95% CI 0.69 to 0.85); 7 trials), but TSA did not confirm these results. Both meta-analysis and TSA showed no significant differences on all-cause mortality, SF-36 mental component score, Minnesota Living with Heart Failure Questionnaire, and stroke. Conclusions Rhythm control strategies compared with rate control strategies seem to significantly increase the risk of a serious adverse event in patients with atrial fibrillation. Based on current evidence, it seems that most patients with atrial fibrillation should be treated with a rate control strategy unless there are specific reasons (e.g., patients with unbearable symptoms due to atrial fibrillation or patients who are hemodynamically unstable due to atrial fibrillation) justifying a rhythm control strategy. More randomized trials at low risk of bias and low risk of random errors are needed. Trial registration PROSPERO CRD42016051433 PMID:29073191

  20. Left atrial dysfunction in patients with patent foramen ovale and atrial septal aneurysm: an alternative concurrent mechanism for arterial embolism?

    PubMed

    Rigatelli, Gianluca; Aggio, Silvio; Cardaioli, Paolo; Braggion, Gabriele; Giordan, Massimo; Dell'avvocata, Fabio; Chinaglia, Mauro; Rigatelli, Giorgio; Roncon, Loris; Chen, Jack P

    2009-07-01

    We postulate that, in patients with large patent foramen ovales (PFO) and atrial septal aneurysms (ASA), left atrial (LA) dysfunction simulating "atrial fibrillation (AF)-like" pathophysiology might represent an alternate mechanism in the promotion of arterial embolism. Despite prior reports concerning paradoxical embolism through a PFO, the magnitude of this phenomenon as a risk factor for stroke remains undefined, because deep venous thrombosis is infrequently detected in such patients. To test our hypothesis, we prospectively enrolled 98 consecutive patients with previous stroke (mean age 37 +/- 12.5 years, 58 women) referred to our center for catheter-based PFO closure. Baseline values of LA passive and active emptying, LA conduit function, LA ejection fraction, and spontaneous echocontrast (SEC) in the LA and LA appendage were compared with those of 50 AF patients as well as a sex/age/cardiac risk-matched population of 70 healthy control subjects. Pre-closure PFO subjects demonstrated significantly greater reservoir function as well as passive and active emptying, with significantly reduced conduit function and LA ejection fraction, when compared with AF and control patients. Furthermore, in PFO patients, 66.3% (65 of 98) had moderate-to-severe ASA and basal shunt; SEC was observed in 52% of PFO plus ASA patients before closure. Multivariate stepwise logistic regression revealed moderate-to-severe ASA (odds ratio: 9.4, 95% confidence interval: 7.0 to 23.2, p < 0.001) as the most powerful predictor of LA dysfunction. After closure, all LA parameters normalized to the levels of control subjects: no SEC, device-related thrombosis, or aortic erosion were observed on follow-up echocardiography. This study suggests that moderate-to-severe ASA might be associated with LA dysfunction in patients with PFO. The resultant similarities to the pathophysiology of AF might represent an additional contributing mechanism for arterial embolism in such patients.

  1. β-Blockers on Discharge From Acute Atrial Fibrillation Are Associated With Decreased Mortality and Lower Cerebrovascular Accidents in Patients With Heart Failure and Reduced Ejection Fraction.

    PubMed

    Abi Khalil, Charbel; Zubaid, Mohammad; Asaad, Nidal; Rashed, Wafa A; Hamad, Adel Khalifa; Singh, Rajvir; Al Suwaidi, Jassim

    2018-04-01

    The benefits of β-blockers in patients with heart failure (HF) with reduced ejection fraction (HFrEF) and atrial fibrillation (AF) are controversial. The Gulf Survey of Atrial Fibrillation Events was a prospective, multinational, observational registry of consecutive patients with AF recruited from the emergency department (ED). We studied the incidence of 6- and 12-month mortality, hospitalization for HF or AF, and stroke/transient ischemic attacks (TIAs) in patients with HFrEF, in relation to β-blockers on discharge from the ED or the subsequent hospital stay. Of the 344 patients with HFrEF and AF in the GULF-SAFE, 177 patients (53%) were discharged on β-blockers. Mortality was lower in those patients compared with the non-β-blockers group at 6 and 12 months (odds ratios [ORs] 0.31, 95% CI [0.16-0.61]; OR 0.30, 95% CI [0.16-0.55]; P = .001 for both, respectively), so was the risk of stroke/TIAs. However, hospitalizations for AF increased in the β-blockers group. Even after adjustment for several risk variables in 2 different models, the beneficial effect of β-blockers on mortality persisted, at the cost of more hospitalization for AF.

  2. Determinants of plasma NT-pro-BNP levels in patients with atrial fibrillation and preserved left ventricular ejection fraction.

    PubMed

    Letsas, Konstantinos P; Filippatos, Gerasimos S; Pappas, Loukas K; Mihas, Constantinos C; Markou, Virginia; Alexanian, Ioannis P; Efremidis, Michalis; Sideris, Antonios; Maisel, Alan S; Kardaras, Fotios

    2009-02-01

    The present study aimed to investigate the clinical and echocardiographic determinants of plasma NT-pro-BNP levels in patients with atrial fibrillation (AF) and preserved left ventricular ejection fraction (LVEF). NT-pro-BNP levels were measured in 45 patients with paroxysmal AF, 41 patients with permanent AF and 48 controls. NT-pro-BNP levels were found significantly elevated in patients with paroxysmal (215+/-815 pg/ml) and permanent AF (1,086+/-835 pg/ml) in relation to control population (86.3+/-77.9 pg/ml) (P<0.001). According to the univariate linear regression analysis, age, hypertension, beta-blocker use, left atrial diameter (LAD), LVEF and AF status (paroxysmal or permanent or both) were significantly associated with NT-pro-BNP levels (P<0.05). In multiple linear regression analysis, LVEF (B coefficient: -53.030; CI: -95.738 to -10.322; P: 0.015) and LAD (B coefficient: 285.858; CI: 23.731-547.986; P: 0.033) were significant and independent determinants of NT-pro-BNP levels. Plasma NT-pro-BNP levels were significantly higher in patients with paroxysmal and permanent AF compared to those with sinus rhythm in the setting of preserved left ventricular systolic function. LVEF and LAD were independent predictors of NT-pro-BNP levels.

  3. Assessment of Atrial Electromechanical Delay and Left Atrial Mechanical Functions in Patients with Ulcerative Colitis.

    PubMed

    Nar, Gokay; Ergul, Bilal; Aksan, Gokhan; Inci, Sinan

    2016-07-01

    Ulcerative colitis (UC) is a common inflammatory bowel disease causing systemic inflammation, which may also affect the cardiovascular system, as well as other organ systems. The aim of the current study was to evaluate left atrial (LA) mechanical functions and duration of atrial electromechanical delay (AEMD) with echocardiography in patients with UC. A total of 91 patients, 45 with UC (Group 1) and 46 healthy individuals as control (Group 2) were included in the study. The demographic and laboratory data were recorded, and echocardiographic measurements were taken for all patients. In the evaluation of basal clinical and laboratory findings, no difference was detected between the two groups, except for white blood cell count (WBC) (8.26 ± 2.71 vs. 7.06 ± 1.70, P = 0.013) and high-sensitivity C-reactive protein (Hs-CRP; 3.4 ± 1.7 vs. 1.0 ± 0.8, P < 0.001). The echocardiographic assessment revealed that the diastolic parameters such as E-, E/A-, and E- waves decreased in the UC group when compared to the control group. LA mechanical functions were different between groups, except for left atrial (LA) maximal volume: LA minimum volume (22.2 ± 12.9 vs. 15.3 ± 4.7, P = 0.001), LA volume before atrial systole (29.9 ± 14.2 vs. 24.2 ± 4.9, P = 0.021), LA ejection fraction (27.4 ± 16.5 vs. 38.6 ± 10.1, P < 0.001), LA total emptying volume (17.9 ± 6.9 vs. 21.9 ± 5.9, P = 0.004), LA active emptying fraction (27.4 ± 16.5 vs. 38.6 ± 10.1, P < 0.001), LA active emptying volume (7.7 ± 3.6 vs. 9.4 ± 2.9, P = 0.013), LA passive emptying fraction (26.8 ± 10.2 vs. 33.2 ± 9.2, P = 0.002), and LA passive emptying volume (10.3 ± 4.9 vs. 12.5 ± 4.5, P = 0.029). There was a significant difference between the groups in terms of AEMD durations, except time interval from the onset of the P-wave on the surface ECG to the peak of the late diastolic wave (PA) of the tricuspid valve. The correlation analysis revealed that age and duration of disease were correlated with AEMD. The current study reported that LA volume and mechanical functions degenerated and AEMD increased in patients with UC when compared to the control group. These findings demonstrate that UC may have effects on LA electromechanical functions related to duration of disease. © 2016, Wiley Periodicals, Inc.

  4. Left atrial function after Cox's maze operation concomitant with mitral valve operation.

    PubMed

    Itoh, T; Okamoto, H; Nimi, T; Morita, S; Sawazaki, M; Ogawa, Y; Asakura, T; Yasuura, K; Abe, T; Murase, M

    1995-08-01

    This study examined whether the atrial fibrillation that commonly occurs in patients with a mitral valve operation could be eliminated by a concomitant maze operation. Left atrial function after Cox's maze operation performed concomitantly with a mitral valve operation was evaluated in 10 patients ranging in age from 38 to 67 years (mean age, 54 years). Seven patients who had had coronary artery bypass grafting served as the control group. Using transthoracic echocardiography, the ratio between the peak speed of the early filling wave and that of the atrial contraction wave (A/E ratio) and the atrial filling fraction (AFF) were determined from transmitral flow measurements. These two indices have been considered to represent the contribution of left atrial active contraction to ventricular filling. The A/E ratio and the AFF were significantly lower in the maze group (0.35 +/- 0.17 versus 0.97 +/- 0.28 [p < 0.01] and 17.6% +/- 8.8% versus 36.8% +/- 6.4% [p < 0.01], respectively). The A/E ratio and the AFF correlated inversely with age (r = -0.72, p < 0.05 and r = 0.76, p < 0.05, respectively) in the maze group. In an angiographic study, the mean left atrial maximal volume index in the maze group was approximately three times larger than that in the control group (117.5 +/- 24.3 mL/m2 versus 35.3 +/- 6.6 mL/m2 [p < 0.01]). The left atrial active emptying volume index was significantly smaller in patients in the maze group (7.2 +/- 2.5 mL/m2 versus 13.1 +/- 4.6 mL/m2 [p < 0.01]). After the maze procedure performed concomitantly with a mitral valve operation in patients with a dilated left atrium, left atrial contraction is detectable but incomplete in the elderly.

  5. Assessment of Left Atrial Deformation and Function by 2-Dimensional Speckle Tracking Echocardiography in Healthy Dogs and Dogs With Myxomatous Mitral Valve Disease.

    PubMed

    Baron Toaldo, M; Romito, G; Guglielmini, C; Diana, A; Pelle, N G; Contiero, B; Cipone, M

    2017-05-01

    The assessment of left atrial (LA) function by 2-dimensional speckle tracking echocardiography (STE) holds important clinical implications in human medicine. Few similar data are available in dogs. To assess LA function by STE in dogs with and without myxomatous mitral valve disease (MMVD), analyzing LA areas, systolic function, and strain. One hundred and fifty dogs were divided according to the American College of Veterinary Internal Medicine classification of heart failure: 23 dogs in class A, 52 in class B1, 36 in class B2, and 39 in class C + D. Prospective observational study. Conventional morphologic and Doppler variables, LA areas, and STE-based LA strain analysis were performed in all dogs and results were compared among groups. Correlation analysis was carried out between LA STE variables and other echocardiographic variables. Variability study showed good reproducibility for all the tested variables (coefficient of variation <16%). Left atrial areas, fractional area change, peak atrial longitudinal strain (PALS), peak atrial contraction strain, and contraction strain index (CSI) differed significantly between groups B2 and C + D and all the other groups (overall P < .001), whereas only PALS differed between groups B1 and A (P = .01). Left atrial areas increased with progression of the disease, whereas LA functional parameters decreased. Only CSI increased nonsignificantly from group A to group B1 and then progressively decreased. Thirty-one significant correlations (P < .001, r > .3) were found between conventional left heart echocardiographic variables and LA areas and strain variables. Left atrial STE analysis provides useful information on atrial function in the dog, highlighting a progressive decline in atrial function with worsening of MMVD. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Limited left atrial surgical ablation effectively treats atrial fibrillation but decreases left atrial function.

    PubMed

    Compier, Marieke G; Tops, Laurens F; Braun, Jerry; Zeppenfeld, Katja; Klautz, Robert J; Schalij, Martin J; Trines, Serge A

    2017-04-01

    Limited left atrial (LA) surgical ablation with bipolar radiofrequency is considered to be an effective procedure for treatment of atrial fibrillation (AF). We studied whether limited LA surgical ablation concomitant to cardiac surgery is able to maintain LA function. Thirty-six consecutive patients (age 66 ± 12 years, 53% male, 78% persistent AF) scheduled for valve surgery and/or coronary revascularization and concomitant LA surgical ablation were included. Epicardial pulmonary vein isolation (PVI) and additional endo-epicardial lines were performed using bipolar radiofrequency. An age- and gender-matched control group (n = 36, age 66 ± 9 years, 69% male, 81% paroxysmal AF) was selected from patients undergoing concomitant epicardial PVI only. Left atrial dimensions and function were assessed on two-dimensional echocardiography preoperatively and at 3- and 12-month follow-up. Sinus rhythm (SR) maintenance was 67% for limited LA ablation and 81% for PVI at 1-year follow-up (P = 0.18). Left atrial volume decreased from 72 ± 21 to 50 ± 14 mL (31%, P < 0.01) after limited LA ablation and from 65 ± 23 to 56 ± 20 mL (14%, P < 0.01) after PVI. Atrial transport function was restored in 54% of patients in SR after limited LA ablation compared with 100% of patients in SR after PVI. Atrial strain and contraction parameters (LA ejection fraction, A-wave velocity, reservoir function, and strain rate) significantly decreased after limited LA ablation. After PVI, strain and contraction parameters remained unchanged. Even limited LA ablation decreased LA volume, contraction, transport function, and compliance, indicating both reverse remodelling combined with significant functional deterioration. In contrast, surgical PVI decreased LA volume while function remained unchanged. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  7. Impact of pacing and high-pass filter settings on ventricular bipolar electrograms in implantable cardioverter defibrillator systems. - Implication of predictors for inappropriate therapy caused by oversensing of repolarization electrograms-.

    PubMed

    Maesato, Akira; Higa, Satoshi; Lin, Yenn-Jiang; Chinen, Ichiro; Ishigaki, Sugako; Yajima, Machiko; Masuzaki, Hiroaki; Chen, Shih-Ann

    2011-01-01

    Predictors of T wave oversensing with implantable cardioverter-defibrillator (ICD) systems remains to be clarified. Thirteen consecutive patients who underwent ICD implantations were included. The depolarization (R) and repolarization (T) of bipolar electrograms during baseline, AAI and DDD modes, and an isoproterenol (ISO) infusion were evaluated. The R wave amplitude during DDD was significantly lower as compared to that during the other conditions in all high-pass filter settings. In contrast, there was no significant difference in the T wave amplitude during the DDD as compared to the other conditions. With the DDD, there was a significantly higher incidence of a T/R ratio of greater than 0.25 as compared to that with the other conditions. T wave amplitude in Brugada syndrome was significantly higher than that in non-Brugada syndrome. The existence of Brugada syndrome and T/R ratio during the AAI with a high-pass filter setting of 10/20 Hz was an excellent predictor of T wave oversensing in the follow-up period. DDD had a significant impact on the R wave amplitude reduction and the T/R ratio during AAI can be predictors of T wave oversensing. These findings have important implications for inappropriate shocks due to T wave oversensing.

  8. Increased α-Actinin-2 Expression in the Atrial Myocardium of Patients with Atrial Fibrillation Related to Rheumatic Heart Disease.

    PubMed

    Zhang, Lei; Zhang, Nan; Tang, Xuejiao; Liu, Fajin; Luo, Suxin; Xiao, Hua

    Atrial fibrosis, a marker of atrial structural remodeling, plays a critical role in atrial fibrillation (AF). α- Actinin-2 is associated with structural remodeling related to stretching. The transforming growth factor-β1 (TGF-β1)/Smad pathway plays an important role in atrial fibrosis. We investigated the effects of the TGF-β1/Smad signaling pathway on α-actinin-2 in atrial fibrosis in patients with AF. Forty-one right atrial specimens obtained from patients with rheumatic heart disease (RHD) were divided into a chronic (c)AF group, i.e. RHD + cAF (n = 29), and a sinus rhythm group, i.e. RHD + sinus rhythm (n = 12). Patients with congenital heart disease (CHD) and sinus rhythm who underwent heart surgery served as controls (n = 10). Fibrosis was assessed by histological examination, and expression of α-actinin-2, TGF-β1 and Smad2/phosphorylated Smad2 (p-Smad2) was evaluated by immunohistochemistry, quantitative real-time PCR and Western blotting. In rat atrial fibroblasts treated with TGF-β1, the collagen content was measured using hydroxyproline detection, and α-actinin-2 and p-Smad2 were evaluated by semiquantitative reverse-transcription PCR and Western blotting. The histology results revealed a significant increase in atrial fibrosis in AF patients. The collagen content, mRNA and protein expression levels of α-actinin-2 and the components of the TGF-β1/Smad signaling pathway were significantly gradually increased in the CHD + sinus rhythm, RHD + sinus rhythm and RHD + cAF groups (p < 0.05). The mRNA and protein levels of α-actinin-2 and TGF-β1 in RHD patients were positively correlated with the collagen volume fraction. A positive correlation between the expression of α-actinin-2 and TGF-β1 was also observed. In rat atrial fibroblasts treated with TGF-β1, the collagen content was greater than that in the control group (p < 0.05), and the expression levels of α- actinin-2 and p-Smad2 were also upregulated (p < 0.05). α-Actinin-2 expression was increased in the atrial tissues of patients with AF secondary to RHD. α-Actinin-2 was upregulated via the TGF-β1/Smad pathway in atrial fibroblasts, which suggests that it may be involved in TGF-β1/Smad pathway-induced atrial fibrosis in patients with AF. © 2016 S. Karger AG, Basel.

  9. Reversible atrial fibrillation following Crotalinae envenomation.

    PubMed

    Quan, Dan; Zurcher, Kenneth

    2017-01-01

    Cardiotoxicity is a documented complication of Crotalinae envenomation. Reported cardiac complications following snake envenomation have included acute myocardial infarction, electrocardiogram abnormalities and arrhythmias. Few reports exist describing arrhythmia induced by viper envenomation and to our knowledge none describe arrhythmia induced by Crotalinae envenomation. This report concerns the first known case of atrial fibrillation precipitated by rattlesnake bite. A 73-year-old Caucasian man with a past medical history of hypertension, hyperlipidemia, type 1 diabetes mellitus, and a baseline first-degree atrioventricular block presented to the emergency department following a rattlesnake bite to his left lower leg. He developed pain and swelling in his left leg two-hour post-envenomation and subsequently received four vials of Crotalidae polyvalent immune fab (ovine). At three-hour post-envenomation following transfer to the intensive care unit, an electrocardiogram revealed new-onset atrial fibrillation. An amiodarone drip was started and the patient successfully converted to normal sinus rhythm approximately six hours after he was found to be in atrial fibrillation. A transthoracic echocardiogram revealed mild concentric left ventricular hypertrophy and an ejection fraction of 72%. He was discharged the following day with no hematological abnormalities and a baseline first-degree atrioventricular block. This is the first documented case of reversible atrial fibrillation precipitated by Crotalinae envenomation. In patients with pertinent risk factors for developing atrial fibrillation, physicians should be aware of the potential for this arrhythmia. Direct toxic effects of venom or structural and electrophysiological cardiovascular abnormalities may predispose snakebite patients to arrhythmia, warranting extended and attentive cardiac monitoring.

  10. Left atrial structure and function in atrial fibrillation: ENGAGE AF-TIMI 48

    PubMed Central

    Gupta, Deepak K.; Shah, Amil M.; Giugliano, Robert P.; Ruff, Christian T.; Antman, Elliott M.; Grip, Laura T.; Deenadayalu, Naveen; Hoffman, Elaine; Patel, Indravadan; Shi, Minggao; Mercuri, Michele; Mitrovic, Veselin; Braunwald, Eugene; Solomon, Scott D.

    2014-01-01

    Aims The complex relationship between left atrial (LA) structure and function, electrical burden of atrial fibrillation (AF) and stroke risk is not well understood. We aimed to describe LA structure and function in AF. Methods and results Left atrial structure and function was assessed in 971 subjects enrolled in the echocardiographic substudy of ENGAGE AF-TIMI 48. Left atrial size, emptying fraction (LAEF), and contractile function were compared across AF types (paroxysmal, persistent, or permanent) and CHADS2 scores as an estimate of stroke risk. The majority of AF patients (55%) had both LA enlargement and reduced LAEF, with an inverse relationship between LA size and LAEF (R = −0.57, P < 0.001). With an increasing electrical burden of AF and higher CHADS2 scores, LA size increased and LAEF declined. Moreover, 19% of AF subjects had impaired LAEF despite normal LA size, and LA contractile dysfunction was present even among the subset of AF subjects in sinus rhythm at the time of echocardiography. Conclusions In a contemporary AF population, LA structure and function were increasingly abnormal with a greater electrical burden of AF and higher stroke risk estimated by the CHADS2 score. Moreover, LA dysfunction was present despite normal LA size and sinus rhythm, suggesting that the assessment of LA function may add important incremental information in the evaluation of AF patients. Clinical Trial Registration: http://www.clinicaltrials.gov; ID = NCT00781391. PMID:24302269

  11. Left atrial appendage resection can be performed minimally invasively with good clinical and echocardiographic outcomes without any severe risk.

    PubMed

    Inoue, Takafumi; Suematsu, Yoshihiro

    2018-01-22

    The adverse effects of left atrial appendage (LAA) closure have not yet been evaluated. This study aimed to prove the safety and low invasiveness of LAA resection through our thoracoscopic stand-alone left atrial appendectomy experience. Eighty-seven patients [mean age 68 ± 9 years, 68 men (78%), mean congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischaemic attack to thromboembolism, vascular disease, age 65-74 years and sex category (CHA2DS2-VASc) score 2.9 ± 1.6 points] who had undergone thoracoscopic left atrial appendectomy were selected. The operative and clinical data (left atrial diameter, left ventricular diameter of systole/diastole, ejection fraction, brain natriuretic peptide and human atrial natriuretic peptide) were evaluated. All procedures were performed without cardiopulmonary bypass or cardiac arrest. The LAA was resected with an endoscopic linear cutter device. Except for 1 case with severe pleural adhesion, all operations were performed thoracoscopically. The preoperative and postoperative data are as follows: left atrial diameter 43 ± 5 mm and 43 ± 5 mm (P = 0.8); left ventricular diameter of systole/diastole 50 ± 5/35 ± 6 mm and 48 ± 5/34 ± 6 mm (P < 0.01); ejection fraction 57 ± 10% and 56 ± 10% (P = 0.11); brain natriuretic peptide 97 ± 77 pg/ml and 72 ± 65 pg/ml (P < 0.01) and human atrial natriuretic peptide 73 ± 64 pg/ml and 96 ± 67 pg/ml (P = 0.03), respectively. The mean volume of bleeding in the operation was very small (<10 ml). The mean length of postoperative in-hospital stay was 3.8 ± 1.8 days. All the patients were discharged while maintaining their preoperative activities of daily living without major complications. No thrombus or residual stumps were detected during the 3-month postoperative computed tomography follow-up. The perioperative heart function did not change significantly in this study. Bleeding with resection was minimal, and no rebleeding events occurred. LAA resection did not affect negatively on the cardiac function and did not increase the risk of bleeding risk. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. A Prospective Survey of Atrial Fibrillation Management for Real-world Guideline Adherence: COmparison study of Drugs for symptom control and complication prEvention of Atrial Fibrillation (CODE-AF) Registry.

    PubMed

    Kim, Hyeongsoo; Kim, Tae Hoon; Cha, Myung Jin; Lee, Jung Myung; Park, Junbeom; Park, Jin Kyu; Kang, Ki Woon; Shim, Jaemin; Uhm, Jae Sun; Kim, Jun; Park, Hyung Wook; Choi, Eue Keun; Kim, Jin Bae; Kim, Changsoo; Lee, Young Soo; Joung, Boyoung

    2017-11-01

    The aging population is rapidly increasing, and atrial fibrillation (AF) is becoming a significant public health burden in Asia, including Korea. This study evaluated current treatment patterns and guideline adherence of AF treatment. In a prospective observational registry (COmparison study of Drugs for symptom control and complication prEvention of Atrial Fibrillation [CODE-AF] registry), 6,275 patients with nonvalvular AF were consecutively enrolled between June 2016 and April 2017 from 10 tertiary hospitals in Korea. The AF type was paroxysmal, persistent, and permanent in 65.3%, 30.0%, and 2.9% of patients, respectively. Underlying structural heart disease was present in 11.9%. Mean CHA₂DS₂-VASc was 2.7±1.7. Oral anticoagulation (OAC), rate control, and rhythm control were used in 70.1%, 53.9%, and 54.4% of patients, respectively. OAC was performed in 82.7% of patients with a high stroke risk. However, antithrombotic therapy was inadequately used in 53.4% of patients with a low stroke risk. For rate control in 192 patients with low ejection fraction (<40%), β-blocker (65.6%), digoxin (5.2%), or both (19.3%) were adequately used in 90.1% of patients; however, a calcium channel blocker was inadequately used in 9.9%. A rhythm control strategy was chosen in 54.4% of patients. The prescribing rate of class Ic antiarrythmics, dronedarone, and sotalol was 16.9% of patients with low ejection fraction. This study shows how successfully guidelines can be applied in the real world. The nonadherence rate was 17.2%, 9.9%, and 22.4% for stroke prevention, rate control, and rhythm control, respectively. Copyright © 2017. The Korean Society of Cardiology

  13. Global longitudinal strain in patients with suspected heart failure and a normal ejection fraction: does it improve diagnosis and risk stratification?

    PubMed

    Pellicori, Pierpaolo; Kallvikbacka-Bennett, Anna; Khaleva, Olga; Carubelli, Valentina; Costanzo, Pierluigi; Castiello, Teresa; Wong, Kenneth; Zhang, Jufen; Cleland, John G F; Clark, Andrew L

    2014-01-01

    Many patients have clinical, structural or bio-marker evidence of heart failure (HF) but a normal left ventricular ejection fraction (LVEF; HeFNEF). Measurement of global longitudinal strain (GLS) may add diagnostic and prognostic information. Patients with symptoms suggesting heart failure and LVEF ≥50% were studied: 76 had no substantial cardiac dysfunction (left atrial diameter (LAD) <40 mm and amino-terminal pro-brain natriuretic peptide (NTproBNP) <400 ng/l); 99 had "possible HeFNEF" (LAD ≥40 mm or NTproBNP ≥400 ng/l); and 138 had "definite HeFNEF" (LAD ≥40 mm and NTproBNP ≥400 ng/L). Mean LVEF was 58% in each subgroup. Patients with definite HeFNEF were older, more likely to have atrial fibrillation, had more symptoms and signs of fluid retention, were more likely to have right ventricular dysfunction and had higher pulmonary pressures than other groups. Mean GLS (SD) was less negative in patients with definite HeFNEF (-13.6 (3.0)% vs. possible HeFNEF: -15.2 (3.1)% vs. no substantial cardiac dysfunction: -15.9 (2.4)%; p < 0.001). GLS was -19.1 (2.1)% in 20 controls. During a median follow up of 647 days, cardiovascular death or an unplanned hospitalisation for heart failure occurred in 62 patients. In univariable analysis, GLS but not LVEF predicted events. However, in a multi-variable analysis, only urea, NTproBNP, left atrial volume, inferior vena cava diameter and atrial fibrillation independently predicted adverse outcome. GLS is abnormal in patients who have other evidence of HeFNEF, is associated with a worse prognosis in this population but is not a powerful independent predictor of outcome.

  14. The importance of integrated left atrial evaluation: From hypertension to heart failure with preserved ejection fraction.

    PubMed

    Beltrami, Matteo; Palazzuoli, Alberto; Padeletti, Luigi; Cerbai, Elisabetta; Coiro, Stefano; Emdin, Michele; Marcucci, Rossella; Morrone, Doralisa; Cameli, Matteo; Savino, Ketty; Pedrinelli, Roberto; Ambrosio, Giuseppe

    2018-02-01

    Functional analysis and measurement of left atrium are an integral part of cardiac evaluation, and they represent a key element during non-invasive analysis of diastolic function in patients with hypertension (HT) and/or heart failure with preserved ejection fraction (HFpEF). However, diastolic dysfunction remains quite elusive regarding classification, and atrial size and function are two key factors for left ventricular (LV) filling evaluation. Chronic left atrial (LA) remodelling is the final step of chronic intra-cavitary pressure overload, and it accompanies increased neurohormonal, proarrhythmic and prothrombotic activities. In this systematic review, we aim to purpose a multi-modality approach for LA geometry and function analysis, which integrates diastolic flow with LA characteristics and remodelling through application of both traditional and new diagnostic tools. The most important studies published in the literature on LA size, function and diastolic dysfunction in patients with HFpEF, HT and/or atrial fibrillation (AF) are considered and discussed. In HFpEF and HT, pulsed and tissue Doppler assessments are useful tools to estimate LV filling pressure, atrio-ventricular coupling and LV relaxation but they need to be enriched with LA evaluation in terms of morphology and function. An integrated evaluation should be also applied to patients with a high arrhythmic risk, in whom eccentric LA remodelling and higher LA stiffness are associated with a greater AF risk. Evaluation of LA size, volume, function and structure are mandatory in the management of patients with HT, HFpEF and AF. A multi-modality approach could provide additional information, identifying subjects with more severe LA remodelling. Left atrium assessment deserves an accurate study inside the cardiac imaging approach and optimised measurement with established cut-offs need to be better recognised through multicenter studies. © 2017 John Wiley & Sons Ltd.

  15. Modified radial v/s biatrial maze for atrial fibrillation in rheumatic valvular heart surgery.

    PubMed

    Sayed, Sajid A; Katewa, Ashish; Srivastava, Vivek; Jana, Sujit; Patwardhan, Anil M

    2014-01-01

    Atrial fibrillation (AF) is commonest sustained atrial arrhythmia producing high morbidity. Although Cox's Maze III procedure cures AF in majority, reduced atrial transport function (ATF) is a concern. Radial approach with ablation lines radial from sinus node towards atrioventricular annulii and parallel to atrial coronary arteries, has shown better ATF. Single blind open randomized prospective study of 80 patients was undertaken in two groups (40 each) of modified Cox's maze III and modified radial approach, to evaluate conversion to normal sinus rhythm (NSR) and ATF. Patients undergoing surgery for rheumatic valvular heart disease with continuous AF were prospectively randomized. Ablation lines were created with radiofrequency (RF) bipolar coagulation with cryoablation for the isthmal lesions and coronary sinus. Results were compared at 6 months and ATF was evaluated by atrial filling fraction (AFF) and A/E ratio on echocardiography. The rate of conversion to NSR in both groups was statistically insignificant by Fisher's exact test (p > 0.05). ATF was better in modified radial approach compared to modified Cox's Maze III (A/E compared by unpaired t test:0.52 ± 0.08 v/s 0.36 ± 0.10; p < 0.05. AFF compared using Mann Whitney U test: median AFF for radial group was 23 v/s 20 for biatrial group; p < 0.05). In patients with AF undergoing rheumatic valvular surgery, radiofrequency radial approach is as effective as modified Cox's maze III for conversion to NSR with better atrial transport function. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  16. Atrial cellular electrophysiological changes in patients with ventricular dysfunction may predispose to AF

    PubMed Central

    Workman, Antony J; Pau, Davide; Redpath, Calum J; Marshall, Gillian E; Russell, Julie A; Norrie, John; Kane, Kathleen A; Rankin, Andrew C

    2009-01-01

    Background Left ventricular systolic dysfunction (LVSD) is a risk factor for atrial fibrillation (AF), but the atrial cellular electrophysiological mechanisms in humans are unclear. Objective To investigate whether LVSD in patients who are in sinus rhythm (SR) is associated with atrial cellular electrophysiological changes which could predispose to AF. Methods Right atrial myocytes were obtained from 214 consenting patients in SR who were undergoing cardiac surgery. Action potentials or ion currents were measured using the whole-cell-patch clamp technique. Results The presence of moderate or severe LVSD was associated with a shortened atrial cellular effective refractory period, ERP (209±8 ms; 52 cells, 18 patients vs 233±7 ms; 134 cells, 49 patients; P<0.05); confirmed by multiple linear regression analysis. The LV ejection fraction (LVEF) was markedly lower in patients with moderate or severe LVSD (36±4%, n=15) than in those without LVSD (62±2%, n=31; P<0.05). In cells from patients with LVEF≤45%, the ERP and action potential duration at 90% repolarisation were shorter than in those from patients with LVEF>45%, by 24 and 18%, respectively. The LVEF and ERP were positively correlated (r=0.65, P<0.05). The L-type calcium ion current, inward rectifier potassium ion current, and sustained outward ion current was unaffected by LVSD. The transient outward potassium ion current was decreased by 34%, with a positive shift in its activation voltage, and no change in its decay kinetics. Conclusion LVSD in patients in SR is independently associated with a shortening of the atrial cellular ERP, which may be expected to contribute to a predisposition to AF. PMID:19324301

  17. Early improvement in left atrial remodeling and function after mitral valve repair or replacement in organic symptomatic mitral regurgitation assessed by three-dimensional echocardiography.

    PubMed

    Le Bihan, David C S; Della Togna, Dorival Julio; Barretto, Rodrigo B M; Assef, Jorge Eduardo; Machado, Lúcia Romero; Ramos, Auristela Isabel de Oliveira; Abdulmassih Neto, Camilo; Moisés, Valdir Ambrosio; Sousa, Amanda G M R; Campos, Orlando

    2015-07-01

    Left atrial (LA) dilation is associated with worse prognosis in various clinical situations including chronic mitral regurgitation (MR). Real time three-dimensional echocardiography (3DE) has allowed a better assessment of LA volumes and function. Little is known about LA size and function in early postoperative period in symptomatic patients with chronic organic MR. We aimed to investigate these aspects. By means of 3DE, 43 patients with symptomatic chronic organic MR were prospectively studied before and 30 days after surgery (repair or bioprosthetic valve replacement). Twenty subjects were studied as controls. Maximum (Vol-max), minimum, and preatrial contraction LA volumes were measured and total, passive, and active LA emptying fractions were calculated. Before surgery patients had higher LA volumes (P < 0.001) but smaller LA emptying fractions than controls (P < 0.01). After surgery there was a reduction in all 3 LA volumes and an increase in active atrial emptying fraction (AAEF). Multivariate analysis showed that independent predictors of early postoperative Vol-max reduction were preoperative diastolic blood pressure (coefficient = -0.004; P = 0.02), lateral mitral annular early diastolic velocity (e') (coefficient = 0.023; P = 0.008), and the mean transmitral diastolic gradient increment (coefficient = -0.035; P < 0.001). Furthermore, e' was also independently associated with AAEF increase (odds ratio = 1.66, P = 0.027). Early LA reverse remodeling and functional improvement occur after successful surgery of symptomatic organic MR regardless of surgical technique. Diastolic blood pressure and transmitral mean gradient augmentation are variables negatively related to Vol-max reduction. Besides, e' is positively correlated with both Vol-max reduction and AAEF increase. © 2014, Wiley Periodicals, Inc.

  18. Hawthorn (Crataegus monogyna Jacq.) extract exhibits atropine-sensitive activity in a cultured cardiomyocyte assay.

    PubMed

    Salehi, Satin; Long, Shannon R; Proteau, Philip J; Filtz, Theresa M

    2009-01-01

    Hawthorn (Crataegus spp.) plant extract is used as a herbal alternative medicine for the prevention and treatment of various cardiovascular diseases. Recently, it was shown that hawthorn extract preparations caused negative chronotropic effects in a cultured neonatal murine cardiomyocyte assay, independent of beta-adrenergic receptor blockade. The aim of this study was to further characterize the effect of hawthorn extract to decrease the contraction rate of cultured cardiomyocytes. To test the hypothesis that hawthorn is acting via muscarinic receptors, the effect of hawthorn extract on atrial versus ventricular cardiomyocytes in culture was evaluated. As would be expected for activation of muscarinic receptors, hawthorn extract had a greater effect in atrial cells. Atrial and/or ventricular cardiomyocytes were then treated with hawthorn extract in the presence of atropine or himbacine. Changes in the contraction rate of cultured cardiomyocytes revealed that both muscarinic antagonists significantly attenuated the negative chronotropic activity of hawthorn extract. Using quinuclidinyl benzilate, L-[benzylic-4,4'-(3)H] ([(3)H]-QNB) as a radioligand antagonist, the effect of a partially purified hawthorn extract fraction to inhibit muscarinic receptor binding was quantified. Hawthorn extract fraction 3 dose-dependently inhibited [(3)H]-QNB binding to mouse heart membranes. Taken together, these findings suggest that decreased contraction frequency by hawthorn extracts in neonatal murine cardiomyocytes may be mediated via muscarinic receptor activation.

  19. Electrophysiological markers predicting impeding AV-block during ablation of atrioventricular nodal reentry tachycardia.

    PubMed

    Fragakis, Nikolaos; Krexi, Lydia; Kyriakou, Panagiota; Sotiriadou, Melani; Lazaridis, Charalambos; Karamanolis, Athanasios; Dalampyras, Panagiotis; Tsakiroglou, Stelios; Skeberis, Vassilios; Tsalikakis, Dimitrios; Vassilikos, Vassilios

    2018-01-01

    Radiofrequency (RF) ablation of the slow pathway (SP) in atrioventricular nodal reentry tachycardia (AVNRT) is occasionally complicated with atrioventricular block (AVB) often predicted by junctional beats (JB) with loss of ventriculo-atrial (VA) conduction. We analyzed retrospectively 153 patients undergoing ablation of SP for typical AVNRT. Patients were divided into two age groups: 127 ≤ 70 years and 26 > 70 years. We analyzed the interval between the atrial electrogram in the His-bundle position and the distal ablation catheter [A(H)-A(RFd)] and between the distal ablation catheter and the proximal coronary sinus catheter [A(RFd)-A(CS)] before RF applications with and without JB. We evaluated if these intervals can be used as predictors of JB incidence and also of JB with loss of VA conduction. We also assessed if age influences the risk of loss of VA conduction. The A(H)-A(RFd) and A(RFd)-A(CS) intervals were significantly shorter in RF applications causing JB than those without JB (33 ± 11 ms vs 39 ± 9 ms, P < 0.001, 14 ± 9 ms vs 20 ± 7 ms, P < 0.001, respectively). The A(H)-A(RFd) and A(RFd)-A(CS) intervals were also significantly shorter in RFs causing JB with VA block than those with VA conduction (29 ± 11 ms vs 35 ± 11 ms, P < 0.001, 8 ± 8 ms vs 17 ± 8 ms, P < 0.001, respectively). Patients > 70 years had shorter intervals (36 ± 11 ms vs 29 ± 8 ms, P  =  0.012, 17 ± 8 ms vs 13 ± 7 ms, P  =  0.027, respectively), while VA block was more common in this age group. The A(H)-A(RFd) and A(RFd)-A(CS) intervals can be used as markers for predicting JB occurrence as well as impending AVB. JB with loss of VA conduction occur more often in older patients possibly due to a higher position of SP. © 2017 Wiley Periodicals, Inc.

  20. Association of Fibroblast Growth Factor 23 With Atrial Fibrillation in Chronic Kidney Disease, From the Chronic Renal Insufficiency Cohort Study

    PubMed Central

    Mehta, Rupal; Cai, Xuan; Lee, Jungwha; Scialla, Julia J.; Bansal, Nisha; Sondheimer, James H.; Chen, Jing; Hamm, L. Lee; Ricardo, Ana C.; Navaneethan, Sankar D.; Deo, Rajat; Rahman, Mahboob; Feldman, Harold I.; Go, Alan S.; Isakova, Tamara; Wolf, Myles

    2016-01-01

    Importance Levels of fibroblast growth factor 23 (FGF23) are elevated in chronic kidney disease (CKD) and strongly associated with left ventricular hypertrophy, heart failure, and death. Whether FGF23 is an independent risk factor for atrial fibrillation in CKD is unknown. Objective To investigate the association of FGF23 with atrial fibrillation in CKD. Design, Setting, and Participants Prospective cohort study of 3876 individuals with mild to severe CKD who enrolled in the Chronic Renal Insufficiency Cohort Study between June 19, 2003, and September 3, 2008, and were followed up through March 31, 2013. Exposures Baseline plasma FGF23 levels. Main Outcomes and Measures Prevalent and incident atrial fibrillation. Results The study cohort comprised 3876 participants. Their mean (SD) age was 57.7 (11.0) years, and 44.8% (1736 of 3876) were female. Elevated FGF23 levels were independently associated with increased odds of prevalent atrial fibrillation (n = 660) after adjustment for cardiovascular and CKD-specific factors (odds ratio of highest vs lowest FGF23 quartile, 2.30; 95% CI, 1.69-3.13; P < .001 for linear trend across quartiles). During a median follow-up of 7.6 years (interquartile range, 6.3-8.6 years), 247 of the 3216 participants who were at risk developed incident atrial fibrillation (11.9 events per 1000 person-years). In fully adjusted models, elevated FGF23 was independently associated with increased risk of incident atrial fibrillation after adjustment for demographic, cardiovascular, and CKD-specific factors, and other markers of mineral metabolism (hazard ratio of highest vs lowest FGF23 quartile, 1.59; 95% CI, 1.00-2.53; P = .02 for linear trend across quartiles). The results were unchanged when further adjusted for ejection fraction, but individual adjustments for left ventricular mass index, left atrial area, and interim heart failure events partially attenuated the association of elevated FGF23 with incident atrial fibrillation. Conclusions and Relevance Elevated FGF23 is independently associated with prevalent and incident atrial fibrillation in patients with mild to severe CKD. The effect may be partially mediated through a diastolic dysfunction pathway that includes left ventricular hypertrophy, atrial enlargement, and heart failure events. PMID:27434583

  1. Changes in left atrial deformation in hypertrophic cardiomyopathy: Evaluation by vector velocity imaging

    PubMed Central

    Badran, Hala Mahfouz; Soltan, Ghada; Hassan, Hesham; Nazmy, Ahmed; Faheem, Naglaa; Saadan, Haythem; Yacoub, Magdi H.

    2012-01-01

    Abstract: Objectives: Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. We assessed the global and regional left atrial (LA) function and its relation to left ventricular (LV) mechanics and clinical status in patients with HCM using Vector Velocity Imaging (VVI). Methods: VVI of the LA and LV was acquired from apical four- and two-chamber views of 108 HCM patients (age 40 ± 19years, 56.5% men) and 33 healthy subjects, all had normal LV systolic function. The LA subendocardium was traced to obtain atrial volumes, ejection fraction, velocities, and strain (ϵ)/strain rate (SR) measurements. Results: Left atrial reservoir (ϵsys,SRsys) and conduit (early diastolic SRe) function were significantly reduced in HCM compared to controls (P < .0001). Left atrial deformation directly correlated to LVϵsys, SRsys and negatively correlated to age, NYHA class, left ventricular outflow tract (LVOT) gradient, left ventricular mass index (LVMI), LA volume index and severity of mitral regurge (P < 0.001). Receiver operating characterist was constructed to explore the cutoff value of LA deformation in differentiation of LA dysfunction; ϵsys < 40% was 75% sensitive, 50% specific, SRsys < 1.7s− 1 was 70% sensitive, 61% specific, SRe> − 1.8s− 1 was 81% sensitive and 30% specific, SRa> − 1.5s− 1 was 73% sensitive and 40% specific. By multivariate analysis global LVϵsys and LV septal thickness are independent predictors for LAϵsys, while end systolic diameter is the only independent predictor for SRsys, P < .001. Conclusion: Left atrial reservoir and conduit function as measured by VVI were significantly impaired while contractile function was preserved among HCM patients. Left atrial deformation was greatly influenced by LV mechanics and correlated to severity of phenotype. PMID:24688992

  2. T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

    NASA Technical Reports Server (NTRS)

    Hohnloser, S. H.; Klingenheben, T.; Li, Y. G.; Zabel, M.; Peetermans, J.; Cohen, R. J.

    1998-01-01

    INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.

  3. Metabolic Syndrome Is Associated with Atrial Electrical and Mechanical Dysfunction

    PubMed Central

    Yilmaz, Hale; Özcan, Kazım Serhan; Sayar, Nurten; Kemaloglu, Tugba; Gungor, Baris; Erer, Betul; Yilmaz, Mehmet; Gurkan, Ufuk; Cakmak, Nazmiye; Oz, Dilaver; Calik, Ali Nazmi; Bolca, Osman

    2015-01-01

    Objective In this study, we aimed to investigate the left atrial (LA) electrical and mechanical functions in patients with metabolic syndrome (MetS). Subjects and Methods The study population consisted of 87 patients with MetS and 67 controls. Intra-atrial and interatrial electromechanical delays (EDs) were measured with tissue Doppler imaging. P-wave dispersion (Pd) was calculated from the 12-lead electrocardiograms. LA volumes were measured echocardiographically by the biplane area-length method. Results Intra-atrial and interatrial EDs and Pd were significantly higher in patients with MetS (10.3 ± 6.3, 21.0 ± 11.5 and 41.7 ± 10.8) than in controls (7.4 ± 5.5, 12.3 ± 10.4 and 29.2 ± 7.4; p = 0.003, p < 0.001 and p < 0.001, respectively). The LA preatrial contraction volume and active emptying volumes were higher in this population, but the LA passive emptying fraction was lower. In the multivariate linear regression analysis, the presence of MetS, LA active emptying volume and left ventricular early diastolic (E) wave velocity/late diastolic (A) wave velocity (E/A) ratios were independent correlates of interatrial ED (p = 0.002, p = 0.001 and p = 0.025, respectively). Conclusions This study showed that intra-atrial and interatrial EDs and Pd were prolonged and LA mechanical functions were impaired in patients with MetS. PMID:25592764

  4. Lysability of fibrin clots is a potential new determinant of stroke risk in atrial fibrillation.

    PubMed

    Skov, Jane; Sidelmann, Johannes J; Bladbjerg, Else-Marie; Jespersen, Jørgen; Gram, Jørgen

    2014-09-01

    Atrial fibrillation increases the risk of ischemic stroke, but the risk depends on other factors as well. Present risk stratification schemes use age and co-morbidities, but not biochemical markers. We investigated the hypothesis that the formation, structure and lysability of fibrin clots are potential determinants of stroke risk in patients with atrial fibrillation. A total of 179 patients with atrial fibrillation in stable anticoagulant treatment were included. Thirty-two had a previous ischemic stroke. We measured thrombin generation, plasma concentrations of fibrinogen and C-reactive protein and analysed fibrin structure and lysability by turbidity. Fibrinolytic capacity was measured using the euglobulin fraction of plasma expressed in terms of t-PA equivalents (IU/ml). The patients with previous stroke had a slightly higher burden of co-morbidities compared with the remaining patients as indicated by the CHA2DS2-VASc score, but no significant differences were found regarding age, fibrinogen concentration, C-reactive protein, thrombin generation or fibrinolytic capacity. Furthermore, the patients with previous stroke had a higher mass/length ratio of fibrin fibers (5.5 vs. 5.1 x10(12) Da/cm, p=0.044) and an increased lysability (79.3 vs. 55.3%, p<0.01). The higher lysability of fibrin clots in atrial fibrillation patients with previous stroke is most likely a result of a difference in fibrin fiber properties. An increased lysability may increase the risk of embolization of clots formed in the atria, and therefore fibrin clot structure seems to be a determinant of stroke risk in atrial fibrillation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Third-generation mobile phones (UMTS) do not interfere with permanent implanted pacemakers.

    PubMed

    Ismail, Mohamed M; Badreldin, Akmal M A; Heldwein, Matthias; Hekmat, Khosro

    2010-07-01

    Third-generation mobile phones, UMTS (Universal Mobile Telecommunication System), were recently introduced in Europe. The safety of these devices with regard to their interference with implanted pacemakers is as yet unknown and is the point of interest in this study. The study comprised 100 patients with permanent pacemaker implantation between November 2004 and June 2005. Two UMTS cellular phones (T-Mobile, Vodafone) were tested in the standby, dialing, and operating mode with 23 single-chamber and 77 dual-chamber pacemakers. Continuous surface electrocardiograms (ECGs), intracardiac electrograms, and marker channels were recorded when calls were made by a stationary phone to cellular phone. All pacemakers were tested under a "worst-case scenario," which includes a programming of the pacemaker to unipolar sensing and pacing modes and inducing of a maximum sensitivity setting during continuous pacing of the patient. Patients had pacemaker implantation between June 1990 and April 2005. The mean age was 68.4 +/- 15.1 years. Regardless of atrial and ventricular sensitivity settings, both UMTS mobile phones (Nokia 6650 and Motorola A835) did not show any interference with all tested pacemakers. In addition, both cellular phones did not interfere with the marker channels and the intracardiac ECGs of the pacemakers. Third-generation mobile phones are safe for patients with permanent pacemakers. This is due to the high-frequency band for this system (1,800-2,200 MHz) and the low power output between 0.01 W and 0.25 W.

  6. Distinct contractile and molecular differences between two goat models of atrial dysfunction: AV block-induced atrial dilatation and atrial fibrillation.

    PubMed

    Greiser, Maura; Neuberger, Hans-Ruprecht; Harks, Erik; El-Armouche, Ali; Boknik, Peter; de Haan, Sunniva; Verheyen, Fons; Verheule, Sander; Schmitz, Wilhelm; Ravens, Ursula; Nattel, Stanley; Allessie, Maurits A; Dobrev, Dobromir; Schotten, Ulrich

    2009-03-01

    Atrial dilatation is an independent risk factor for thromboembolism in patients with and without atrial fibrillation (AF). In many patients, atrial dilatation goes along with depressed contractile function of the dilated atria. While some mechanisms causing atrial contractile dysfunction in fibrillating atria have been addressed previously, the cellular and molecular mechanisms of atrial contractile remodeling in dilated atria are unknown. This study characterized in vivo atrial contractile function in a goat model of atrial dilatation and compared it to a goat model of AF. Differences in the underlying mechanisms were elucidated by studying contractile function, electrophysiology and sarcoplasmic reticulum (SR) Ca2+ load in atrial muscle bundles and by analyzing expression and phosphorylation levels of key Ca2+-handling proteins, myofilaments and the expression and activity of their upstream regulators. In 7 chronically instrumented, awake goats atrial contractile dysfunction was monitored during 3 weeks of progressive atrial dilatation after AV-node ablation (AV block goats (AVB)). In open chest experiments atrial work index (AWI) and refractoriness were measured (10 goats with AVB, 5 goats with ten days of AF induced by repetitive atrial burst pacing (AF), 10 controls). Isometric force of contraction (FC), transmembrane action potentials (APs) and rapid cooling contractures (RCC, a measure of SR Ca2+ load) were studied in right atrial muscle bundles. Total and phosphorylated Ca2+-handling and myofilament protein levels were quantified by Western blot. In AVB goats, atrial size increased by 18% (from 26.6+/-4.4 to 31.6+/-5.5 mm, n=7 p<0.01) while atrial fractional shortening (AFS) decreased (from 18.4+/-1.7 to 12.8+/-4.0% at 400 ms, n=7, p<0.01). In open chest experiments, AWI was reduced in AVB and in AF goats compared to controls (at 400 ms: 8.4+/-0.9, n=7, and 3.2+/-1.8, n=5, vs 18.9+/-5.3 mmxmmHg, n=7, respectively, p<0.05 vs control). FC of isolated right atrial muscle bundles was reduced in AVB (n=8) and in AF (n=5) goats compared to controls (n=9) (at 2 Hz: 2.3+/-0.5 and 0.7+/-0.2 vs 5.5+/-1.0 mN/mm2, respectively, p<0.05). APs were shorter in AF, but unchanged in AVB goats. RCCs were reduced in AVB and AF versus control (AVB, 3.4+/-0.5 and AF, 4.1+/-1.4 vs 12.2+/-3.2 mN/mm2, p<0.05). Protein levels of protein kinase A (PKA) phosphorylated phospholamban (PLB) were reduced in AVB (n=8) and AF (n=8) vs control (n=7) by 37.9+/-12.4% and 29.7+/-10.1%, respectively (p<0.01), whereas calmodulin-dependent protein kinase II (CaMKII) phosphorylated ryanodine channels (RyR2) were increased by 166+/-55% in AVB (n=8) and by 146+/-56% in AF (n=8) goats (p<0.01). PKA-phosphorylated myosin-binding protein-C and troponin-I were reduced exclusively in AVB goat atria (by 75+/-10% and 55+/-15%, respectively, n=8, p<0.05). Atrial dilatation developing during slow ventricular rhythm after complete AV block as well as AF-induced remodeling are associated with atrial contractile dysfunction. Both AVB and AF goat atria show decreased SR Ca2+ load, likely caused by PLB dephosphorylation and RYR2 hyperphosphorylation. While shorter APs further compromise contractility in AF goat atria, reduced myofilament phosphorylation may impair contractility in AVB goat atria. Thus, atrial hypocontractility appears to have distinct molecular contributors in different types of atrial remodeling.

  7. Atrial Function in Patients with Breast Cancer After Treatment with Anthracyclines.

    PubMed

    Yaylali, Yalin Tolga; Saricopur, Ahmet; Yurtdas, Mustafa; Senol, Hande; Gokoz-Dogu, Gamze

    2016-11-01

    Atrial electromechanical delay (EMD) is used to predict atrial fibrillation, measured by echocardiography. The aim of this study was to assess atrial EMD and mechanical function after anthracycline-containing chemotherapy. Fifty-three patients with breast cancer (48 ± 8 years old) who received 240 mg/m2of Adriamycin, 2400 mg/m2 of cyclophosphamide, and 960 mg/m2 of paclitaxel were included in this retrospective study, as were 42 healthy subjects (47 ± 9 years old). Echocardiographic measurements were performed 11 ± 7 months (median 9 months) after treatment with anthracyclines. Left intra-atrial EMD (11.4 ± 6.0 vs. 8.1 ± 4.9, p=0.008) and inter-atrial EMD (19.7 ± 7.4 vs. 14.7 ± 6.5, p=0.001) were prolonged; LA passive emptying volume and fraction were decreased (p=0.0001 and p=0.0001); LA active emptying volume and fraction were increased (p=0.0001 and p=0.0001); Mitral A velocity (0.8 ± 0.2 vs. 0.6 ± 0.2, p=0.0001) and mitral E-wave deceleration time (201.2 ± 35.6 vs. 163.7 ± 21.8, p=0.0001) were increased; Mitral E/A ratio (1.0 ± 0.3 vs. 1.3 ± 0.3, p=0.0001) and mitral Em (0.09 ± 0.03 vs. 0.11 ± 0.03, p=0.001) were decreased; Mitral Am (0.11 ± 0.02 vs. 0.09 ± 0.02, p=0.0001) and mitral E/Em ratio (8.8 ± 3.2 vs. 7.6 ± 2.6, p=0.017) were increased in the patients. In patients with breast cancer after anthracycline therapy: Left intra-atrial, inter-atrial electromechanical intervals were prolonged. Diastolic function was impaired. Impaired left ventricular relaxation and left atrial electrical conduction could be contributing to the development of atrial arrhythmias. Atraso eletromecânico atrial (AEA) é utilizado para prever fibrilação atrial, medido pela ecocardiografia. O propósito deste estudo era verificar o AEA e a função mecânica após quimioterapia com antraciclinas. Cinquenta e três pacientes com câncer de mama (48 ± 8 anos) que receberam 240 mg/m2 de adriamicina, 2400 mg/m2 de ciclofosfamida, e 960 mg/m2 de paclitaxel foram incluídas neste estudo retrospectivo, além de 42 indivíduos saudáveis (47 ± 9 anos). Medidas ecocardiográficas foram realizadas por aproximadamente 11 ± 7 meses (média de 9 meses) após tratamento com antraciclinas. AEA esquerdo intra-atrial (11,4 ± 6,0 vs. 8,1 ± 4,9, p=0,008) e AEA interarterial (19,7 ± 7,4 vs. 14,7 ± 6,5, p=0,001) foram prolongados; Volume de esvaziamento passivo e fracionamento de AE diminuíram (p=0,0001 e p=0,0001); Volume de esvaziamento ativo e fracionamento de AE (p=0,0001 e p=0,0001); Tempo de aceleração mitral A (0,8 ± 0,2 vs. 0,6 ± 0,2, p=0,0001) e de desaceleração de onda-E mitral (201,2 ± 35,6 vs. 163,7 ± 21,8, p=0,0001) aumentarão; Razão mitral E/A (1,0 ± 0,3 vs. 1,3 ± 0,3, p=0,0001) e mitral Em (0,09 ± 0,03 vs. 0,11 ± 0,03, p=0,001) diminuíram; Razão mitral Am (0,11 ± 0,02 vs. 0,09 ± 0,02, p=0,0001) e mitral E/Em (8,8 ± 3,2 vs. 7,6 ± 2,6, p=0,017) aumentaram nos pacientes. Em pacientes com câncer de mama após terapia com antraciclina: intervalos eletromecânicos intra-atriais esquerdos, intra-atriais foram prolongados. A função diastólica foi prejudicada. O relaxamento ventricular esquerdo foi prejudicado, e a condução elétrica atrial esquerda pode estar contribuindo para o desenvolvimento de arritmias atriais.

  8. Methodology to Estimate the Longitudinal Average Attributable Fraction of Guideline-recommended Medications for Death in Older Adults With Multiple Chronic Conditions

    PubMed Central

    Zhan, Yilei; Cohen, Andrew B.; Tinetti, Mary E.; Trentalange, Mark; McAvay, Gail

    2016-01-01

    Background: Persons with multiple chronic conditions receive multiple guideline-recommended medications to improve outcomes such as mortality. Our objective was to estimate the longitudinal average attributable fraction for 3-year survival of medications for cardiovascular conditions in persons with multiple chronic conditions and to determine whether heterogeneity occurred by age. Methods: Medicare Current Beneficiary Survey participants (N = 8,578) with two or more chronic conditions, enrolled from 2005 to 2009 with follow-up through 2011, were analyzed. We calculated the longitudinal extension of the average attributable fraction for oral medications (beta blockers, renin–angiotensin system blockers, and thiazide diuretics) indicated for cardiovascular conditions (atrial fibrillation, coronary artery disease, heart failure, and hypertension), on survival adjusted for 18 participant characteristics. Models stratified by age (≤80 and >80 years) were analyzed to determine heterogeneity of both cardiovascular conditions and medications. Results: Heart failure had the greatest average attributable fraction (39%) for mortality. The fractional contributions of beta blockers, renin–angiotensin system blockers, and thiazides to improve survival were 10.4%, 9.3%, and 7.2% respectively. In age-stratified models, of these medications thiazides had a significant contribution to survival only for those aged 80 years or younger. The effects of the remaining medications were similar in both age strata. Conclusions: Most cardiovascular medications were attributed independently to survival. The two cardiovascular conditions contributing independently to death were heart failure and atrial fibrillation. The medication effects were similar by age except for thiazides that had a significant contribution to survival in persons younger than 80 years. PMID:26748093

  9. [Influence of sinus rhythm restoration and maintenance on left ventricle diameter and function in patients with persistent atrial fibrillation--one year follow-up].

    PubMed

    Kosior, Dariusz A; Szulc, Marcin; Stawicki, Sławomir; Roik, Marek; Rabczenko, Daniel; Opolski, Grzegorz

    2005-01-01

    Aim of our study was to determine the dynamics of selected echocardiographic parameters after sinus rhythm (SR) restoration and maintenance in pts with persistent nonvalvular atrial fibrillation (AF) during one year follow-up period. Our study population comprised 104 pts (F/M 33/71; mean age 60.4 +/- 7.4) assigned to SR restoration and maintenance with serial antiarrhythmic drug usage, for whom transthoracic echocardiographic (TTE) variables were recorded prior to, 2 and 12 months after cardioversion (CD). Left ventricle diastolic diameter and fractional shortening were variables of interest. SR was presented in 66 (63.5%) pts at one year. There was no significant differences in left ventricle diastolic diameter during the follow up. A significant increase in left ventricular fractional shortening (29.9 +/- 6.9% vs 34.5 +/- 8.9%; p < 0.001) was found in pts assigned to the sinus rhythm restoration according to intention-to-treat analysis. Such trend was noted only in pts who maintained SR during the follow up (29.9 +/- 7.6% vs 35.6 +/- 9.3%; p < 0.001). Among all considered variables only value of left ventricular fractional shortening increased after successful CV of persistent AF in one year follow-up.

  10. [Multi-channel data collection and visualization system for intramyocardial electrograms].

    PubMed

    Kastner, P; Wimmer, W; Hutten, H

    2000-11-01

    The aim of the project was to develop a multichannel data acquisition system for the recording and visualisation of intramyocardial electrograms (IEGM) from both the spontaneously beating and the artificially paced heart. Signal processing comprises multi-step amplification, filtering (0.05-800 Hz), and AD conversion (12 Bit max. 6.25 kHz). IEGMs can be obtained either in unipolar or bipolar mode. Stimulation of the heart is achieved by an incorporated programmable dual-chamber pacemaker that can be selectively switched to the input channels. A LabView-based graphical user interface permits the programming of all system parameters via a microcontroller, and supports data acquisition and visualisation. The system can be used in animal experiments to monitor the spread of excitation across the heart, to measure propagation velocity, or to measure the impact of drugs and pathological changes on the morphology of IEGMs.

  11. On the precision of automated activation time estimation

    NASA Technical Reports Server (NTRS)

    Kaplan, D. T.; Smith, J. M.; Rosenbaum, D. S.; Cohen, R. J.

    1988-01-01

    We examined how the assignment of local activation times in epicardial and endocardial electrograms is affected by sampling rate, ambient signal-to-noise ratio, and sinx/x waveform interpolation. Algorithms used for the estimation of fiducial point locations included dV/dtmax, and a matched filter detection algorithm. Test signals included epicardial and endocardial electrograms overlying both normal and infarcted regions of dog myocardium. Signal-to-noise levels were adjusted by combining known data sets with white noise "colored" to match the spectral characteristics of experimentally recorded noise. For typical signal-to-noise ratios and sampling rates, the template-matching algorithm provided the greatest precision in reproducibly estimating fiducial point location, and sinx/x interpolation allowed for an additional significant improvement. With few restrictions, combining these two techniques may allow for use of digitization rates below the Nyquist rate without significant loss of precision.

  12. Left atrial ejection force predicts the outcome after catheter ablation for paroxysmal atrial fibrillation.

    PubMed

    Kishima, Hideyuki; Mine, Takanao; Takahashi, Satoshi; Ashida, Kenki; Ishihara, Masaharu; Masuyama, Tohru

    2018-02-01

    Left atrium (LA) systolic dysfunction is observed in the early stages of atrial fibrillation (AF) prior to LA anatomical change. We investigated whether LA systolic dysfunction predicts recurrent AF after catheter ablation (CA) in patients with paroxysmal AF. We studied 106 patients who underwent CA for paroxysmal AF. LA systolic function was assessed with the LA emptying volume = Maximum LA volume (LAV max ) - Minimum LA volume (LAV min ), LA emptying fraction = [(LAV max - LAV min )/LAV max ] × 100, and LA ejection force calculated with Manning's method [LA ejection force = (0.5 × ρ × mitral valve area × A 2 )], where ρ is the blood density and A is the late-diastolic mitral inflow velocity. Recurrent AF was detected in 35/106 (33%) during 14.6 ± 9.1 months. Univariate analysis revealed reduced LA ejection force, decreased LA emptying fraction, larger LA diameter, and elevated brain natriuretic peptide as significant variables. On multivariate analysis, reduced LA ejection force and larger LA diameter were independently associated with recurrent AF. Moreover, patients with reduced LA ejection force and larger LA diameter had a higher risk of recurrent AF than preserved LA ejection force (log-rank P = 0.0004). Reduced LA ejection force and larger LA diameter were associated with poor outcome after CA for paroxysmal AF, and could be a new index to predict recurrent AF. © 2017 Wiley Periodicals, Inc.

  13. A porcine model of hypertensive cardiomyopathy: implications for heart failure with preserved ejection fraction.

    PubMed

    Schwarzl, Michael; Hamdani, Nazha; Seiler, Sebastian; Alogna, Alessio; Manninger, Martin; Reilly, Svetlana; Zirngast, Birgit; Kirsch, Alexander; Steendijk, Paul; Verderber, Jochen; Zweiker, David; Eller, Philipp; Höfler, Gerald; Schauer, Silvia; Eller, Kathrin; Maechler, Heinrich; Pieske, Burkert M; Linke, Wolfgang A; Casadei, Barbara; Post, Heiner

    2015-11-01

    Heart failure with preserved ejection fraction (HFPEF) evolves with the accumulation of risk factors. Relevant animal models to identify potential therapeutic targets and to test novel therapies for HFPEF are missing. We induced hypertension and hyperlipidemia in landrace pigs (n = 8) by deoxycorticosteroneacetate (DOCA, 100 mg/kg, 90-day-release subcutaneous depot) and a Western diet (WD) containing high amounts of salt, fat, cholesterol, and sugar for 12 wk. Compared with weight-matched controls (n = 8), DOCA/WD-treated pigs showed left ventricular (LV) concentric hypertrophy and left atrial dilatation in the absence of significant changes in LV ejection fraction or symptoms of heart failure at rest. The LV end-diastolic pressure-volume relationship was markedly shifted leftward. During simultaneous right atrial pacing and dobutamine infusion, cardiac output reserve and LV peak inflow velocities were lower in DOCA/WD-treated pigs at higher LV end-diastolic pressures. In LV biopsies, we observed myocyte hypertrophy, a shift toward the stiffer titin isoform N2B, and reduced total titin phosphorylation. LV superoxide production was increased, in part attributable to nitric oxide synthase (NOS) uncoupling, whereas AKT and NOS isoform expression and phosphorylation were unchanged. In conclusion, we developed a large-animal model in which loss of LV capacitance was associated with a titin isoform shift and dysfunctional NOS, in the presence of preserved LV ejection fraction. Our findings identify potential targets for the treatment of HFPEF in a relevant large-animal model. Copyright © 2015 the American Physiological Society.

  14. A review of the appropriate and inappropriate use of dronedarone: lessons learned from controlled studies and regulatory submission.

    PubMed

    Naccarelli, Gerald V; Wolbrette, Deborah L; Samii, Soraya; Banchs, Javier E; Penny-Peterson, Erica; Gonzalez, Mario D

    2010-12-01

    Dronedarone is a multichannel blocker with electrophysiologic effects similar to amiodarone. Dronedarone has been documented to prevent atrial fibrillation recurrences and also has efficacy in slowing the ventricular response during episodes of atrial fibrillation. However, in the ANDROMEDA trial, dronedarone was associated with increased mortality when tested in New York Heart Association (NYHA) III/IV patients with left ventricular ejection fractions of less than 35%, who also had a recent hospitalization for decompensated heart failure. When such high-risk patients with heart failure were excluded in the ATHENA trial, dronedarone treatment resulted in a statistical reduction in the composite primary end point of all-cause mortality or cardiovascular hospitalization. In ATHENA, dronedarone reduced cardiovascular hospitalizations even though in the DIONY-SOS trial dronedarone had less effect than amiodarone on suppressing atrial fibrillation recurrences. The most appropriate patients for treatment with dronedarone would be patients with a recent history of paroxysmal or persistent atrial fibrillation/atrial flutter (AF/AFL) that have associated risk factors per the inclusion criteria of ATHENA. Inappropriate patients would be those with class IV heart failure or recently hospitalized for heart failure within the last month from an acute decompensation, the main inclusion criteria in ANDROMEDA. Dronedarone is a novel, multichannel blocking antiarrhythmic agent that may have some pleiotropic effects in addition to its ability to suppress and maintain sinus rhythm and control the rate during AF/AFL recurrences.

  15. Echocardiographic predictors of atrial fibrillation recurrence after catheter ablation: A literature review.

    PubMed

    Liżewska-Springer, Aleksandra; Dąbrowska-Kugacka, Alicja; Lewicka, Ewa; Drelich, Łukasz; Królak, Tomasz; Raczak, Grzegorz

    2018-06-20

    Catheter ablation (CA) is a well-known treatment option for patients with symptomatic drug-resistant atrial fibrillation (AF). Multiple factors have been identified to determine AF recurrence after CA, however their predictive value is rather small. Identification of novel predictors of CA outcome is therefore of primary importance to reduce health costs and improve long-term results of this intervention. The recurrence of AF following CA is related to the severity of left ventricular (LV) dysfunction, extend of atrial dilatation and fibrosis. The aim of this paper was to present and discuss the latest studies on utility of echocardiographic parameters in terms of CA effectiveness in patients with paroxysmal and persistent AF. PubMed, Google Scholar, EBSCO databases were searched for studies reporting echocardiographic preprocedural predictors of AF recurrence after CA. LV systolic and diastolic function, as well as atrial size, strain and dyssynchrony were taken into consideration. Twenty one full-text articles were analyzed, including three meta-analyses. Several echocardiographic parameters have been reported to determine a risk of AF recurrence after CA. There are conventional methods that measure left atrial (LA) size and volume, LV ejection fraction, parameters assessing LV diastolic dysfunction, and methods using more innovative technologies based on speckle tracking echocardiography (STE) to determine LA synchrony and strain. Each of these parameters has its own predictive value. Regarding CA effectiveness, every patient has to be evaluated individually to estimate the risk of AF recurrence, optimally using a combination of several echocardiographic parameters.

  16. Inverse Correlation between the Atrial Fibrillatory Rate and the Ventricular Repolarization Time: Observations at Baseline and after an Intravenous Infusion of a Combined Potassium and Sodium Current Blocker.

    PubMed

    Edvardsson, Nils; Aunes, Maria; Frison, Lars; Berggren, Anders R

    2016-05-01

    The atrial fibrillatory rate (AFR) and the ventricular rate and repolarization (QTcF) were studied at baseline and under the influence of the combined potassium and sodium current blocker AZD7009. Ninety-two patients with atrial fibrillation (AF) were randomized to an intravenous infusion of AZD7009 or placebo. The atrial fibrillatory activity in lead V1 was extracted using spatiotemporal QRST cancellation. The exponential decay (ED) characterized the degree of atrial signal organization. The mean (SD) AFR at baseline was 396  ±  57 (range 253-584) and 410 ± 33 (range 363-469) bpm in patients randomized to AZD7009 and placebo, respectively. The AFR decreased within the first minutes of the AZD7009 infusion and reached its minimum of 235 ± 34 bpm after 18 minutes. On placebo, the AFR was unchanged. On AZD7009, the ED decreased from 1.2 ± 0.3 to reach its lowest level at 0.7 ± 0.2 after 14 minutes. The ventricular rate did not change significantly over time. The AFR was statistically significantly related to the ventricular repolarization at baseline, the QTcF being longer at lower AFR values, and this relationship remained during and after AZD7009. In the full multivariate linear regression model, including age, sex, left ventricular ejection fraction, QRS duration, heart rate, QTcF, AF episode duration, AF history duration, and right atrial or left atrial size, only QTcF and age were statistically significantly correlated with the AFR. The correlation remained when the uncorrected QT interval was used. The QTcF was inversely correlated with AFR, both at baseline and during administration of AZD7009. The AFR was not correlated with the ventricular rate. © 2015 Wiley Periodicals, Inc.

  17. Systemic right ventricular fibrosis detected by cardiovascular magnetic resonance is associated with clinical outcome, mainly new-onset atrial arrhythmia, in patients after atrial redirection surgery for transposition of the great arteries.

    PubMed

    Rydman, Riikka; Gatzoulis, Michael A; Ho, Siew Yen; Ernst, Sabine; Swan, Lorna; Li, Wei; Wong, Tom; Sheppard, Mary; McCarthy, Karen P; Roughton, Michael; Kilner, Philip J; Pennell, Dudley J; Babu-Narayan, Sonya V

    2015-05-01

    We hypothesized that fibrosis detected by late gadolinium enhancement (LGE) cardiovascular magnetic resonance predicts outcomes in patients with transposition of the great arteries post atrial redirection surgery. These patients have a systemic right ventricle (RV) and are at risk of arrhythmia, premature RV failure, and sudden death. Fifty-five patients (aged 27±7 years) underwent LGE cardiovascular magnetic resonance and were followed for a median 7.8 (interquartile range, 3.8-9.6) years in a prospective single-center cohort study. RV LGE was present in 31 (56%) patients. The prespecified composite clinical end point comprised new-onset sustained tachyarrhythmia (atrial/ventricular) or decompensated heart failure admission/transplantation/death. Univariate predictors of the composite end point (n=22 patients; 19 atrial/2 ventricular tachyarrhythmia, 1 death) included RV LGE presence and extent, RV volumes/mass/ejection fraction, right atrial area, peak Vo(2), and age at repair. In bivariate analysis, RV LGE presence was independently associated with the composite end point (hazard ratio, 4.95 [95% confidence interval, 1.60-15.28]; P=0.005), and only percent predicted peak Vo(2) remained significantly associated with cardiac events after controlling for RV LGE (hazard ratio, 0.80 [95% confidence interval, 0.68-0.95]; P=0.009/5%). In 8 of 9 patients with >1 event, atrial tachyarrhythmia, itself a known risk factor for mortality, occurred first. There was agreement between location and extent of RV LGE at in vivo cardiovascular magnetic resonance and histologically documented focal RV fibrosis in an explanted heart. There was RV LGE progression in a different case restudied for clinical indications. Systemic RV LGE is strongly associated with adverse clinical outcome especially arrhythmia in transposition of the great arteries, thus LGE cardiovascular magnetic resonance should be incorporated in risk stratification of these patients. © 2015 American Heart Association, Inc.

  18. Obese Hypertensive Men Have Lower Circulating Proatrial Natriuretic Peptide Concentrations Despite Greater Left Atrial Size.

    PubMed

    Asferg, Camilla L; Andersen, Ulrik B; Linneberg, Allan; Goetze, Jens P; Jeppesen, Jørgen L

    2018-05-07

    Obese persons have lower circulating natriuretic peptide (NP) concentrations. It has been proposed that this natriuretic handicap plays a role in obesity-related hypertension. In contrast, hypertensive patients with left atrial enlargement have higher circulating NP concentrations. On this background, we investigated whether obese hypertensive men could have lower circulating NP concentrations despite evidence of pressure-induced greater left atrial size. We examined 98 obese men (body mass index [BMI] ≥ 30.0 kg/m2) and 27 lean normotensive men (BMI 20.0-24.9 kg/m2). All men were healthy, medication free, with normal left ventricular ejection fraction. We measured blood pressure using 24-hour ambulatory blood pressure (ABP) recordings. Hypertension was defined as 24-hour ABP ≥ 130/80 mm Hg, and normotension was defined as 24-hour ABP < 130/80 mm Hg. We determined left atrial size using echocardiography, and we measured fasting serum concentrations of midregional proatrial NP (MR-proANP). Of the 98 obese men, 62 had hypertension and 36 were normotensive. The obese hypertensive men had greater left atrial size (mean ± SD: 28.7 ± 6.0 ml/m2) compared with the lean normotensive men (23.5 ± 4.5 ml/m2) and the obese normotensive men (22.7 ± 5.1 ml/m2), P < 0.01. Nevertheless, despite evidence of pressure-induced greater left atrial size, the obese hypertensive men had lower serum MR-proANP concentrations (median [interquartile range]: 48.5 [37.0-64.7] pmol/l) compared with the lean normotensive men (69.3 [54.3-82.9] pmol/l), P < 0.01, whereas the obese normotensive men had serum MR-proANP concentrations in between the 2 other groups (54.1 [43.6-62.9] pmol/l). Despite greater left atrial size, obese hypertensive men have lower circulating MR-proANP concentrations compared with lean normotensive men.

  19. Independence of the blood pressure lowering effect and efficacy of the angiotensin receptor neprilysin inhibitor, LCZ696, in patients with heart failure with preserved ejection fraction: an analysis of the PARAMOUNT trial.

    PubMed

    Jhund, Pardeep S; Claggett, Brian; Packer, Milton; Zile, Michael R; Voors, Adriaan A; Pieske, Burkert; Lefkowitz, Martin; Shi, Victor; Bransford, Toni; McMurray, John J V; Solomon, Scott D

    2014-06-01

    The first in class angiotensin receptor neprilysin inhibitor, LCZ696 has been shown to reduce levels of N-terminal pro-brain natriuretic peptide (NT-proBNP), reduce left atrial size and improve New York Heart Association (NYHA) class in patients with heart failure with preserved ejection fraction (HFpEF). We examined whether the effects of LCZ696 were independent of systolic blood pressure (SBP) lowering. In the Prospective comparison of ARNi (angiotensin receptor neprilysin inhibitor) with ARB (angiotensin receptor blocker) on Management Of heart failUre with preserved ejectioN fracTion (PARAMOUNT) trial 301 patients were randomly assigned to LCZ696 or valsartan. We examined the relationship between SBP lowering and LCZ696 on NT-proBNP level, left atrial size, NYHA class and estimated glomerular filtration rate (eGFR). By 12 weeks blood pressure was reduced by 9 mmHg (SD 15)/5 mmHg (SD 11) in patients receiving LCZ696 in comparison with 3 mmHg (SD 17)/2 mmHg (SD 12) in those receiving valsartan. The change in NT-proBNP was poorly correlated with change in SBP (LCZ696, r = 0.17, P = 0.06; valsartan, r = 0.05, P = 0.58) After adjustment for change in SBP, the ratio of change in NT-proBNP at 12 weeks for LCZ696 vs. valsartan was 0.76 (95% CI 0.63-0.93, P = 0.008), and similar to the ratio not adjusting for SBP (0.76, 95% CI 0.63-0.92, P = 0.006); P for interaction was 0.38). Similarly, reduction in left atrial volume index at 36 weeks, improvement in NYHA class and eGFR were all independent of the change in SBP. In patients with HFpEF, the effect of the angiotensin receptor neprilysin inhibitor LCZ696 on NT-proBNP, left atrial volume, functional class, and eGFR was independent of reduction in SBP. © 2014 The Authors. European Journal of Heart Failure © 2014 European Society of Cardiology.

  20. ASSESSMENT OF DIASTOLIC DYSFUNCTION, ARTERIAL STIFFNESS, AND CAROTID INTIMA-MEDIA THICKNESS IN PATIENTS WITH ACROMEGALY.

    PubMed

    Cansu, Güven Barış; Yılmaz, Nusret; Yanıkoğlu, Atakan; Özdem, Sebahat; Yıldırım, Aytül Belgi; Süleymanlar, Gültekin; Altunbaş, Hasan Ali

    2017-05-01

    Early diagnosis and treatment of cardiovascular diseases, the most frequent cause of morbidity and mortality in acromegaly, may be an efficient approach to extending the lifespan of affected patients. Therefore, it is crucial to determine any cardiovascular diseases in the subclinical period. The study objectives were to determine markers of subclinical atherosclerosis and asses heart structure and function. This was a cross-sectional, single-center study of 53 patients with acromegaly and 22 age- and sex-matched healthy individuals. Carotid intima-media thickness (CIMT), pulse-wave velocity (PWV), and echocardiographic data were compared between these groups. CIMT and PWV were higher in the acromegaly group than in the healthy group (P = .008 and P = .002, respectively). Echocardiography showed that left ventricular diastolic dysfunction was present in 11.3% of patients. Left ventricular mass index and left atrial volume index were higher in the patients (P = .016 and P<.001, respectively). No differences in the CIMT, PWV, or echocardiographic measurements were identified between the patients with biochemically controlled and uncontrolled acromegaly and the control group. Our results showed that subclinical atherosclerosis (i.e., CIMT and PWV markers) and heart structure and function were worse in patients with acromegaly than in healthy individuals. Because there were no differences in these parameters between patients with controlled and uncontrolled acromegaly, our results suggest that the structural and functional changes do not reverse with biochemical control. AA = active acromegaly BSA = body surface area CA = biochemically controlled acromegaly CH = concentric hypertrophy CIMT = carotid intima-media thickness DBP = diastolic blood pressure DM = diabetes mellitus ECHO = echocardiography EDV = enddiastolic volume EF = ejection fraction ESV = endsystolic volume GH = growth hormone HC = healthy control HL = hyperlipidemia HT = hypertension IGF-1 = insulin-like growth factor 1 LA = left atrial LAV = left atrial volume LAVI = left atrial volume index LV = left ventricular LVDD = left ventricular diastolic dysfunction LVEF = left ventricular ejection fraction LVH = left ventricular hypertrophy LVMI = left ventricular mass index PWV = pulse-wave velocity RWT = relative wall thickness.

  1. Effect of mitral regurgitation on cerebrovascular accidents in patients with atrial fibrillation and left atrial thrombus.

    PubMed

    Nair, Chandra K; Aronow, Wilbert S; Shen, Xuedong; Anand, Kishlay; Holmberg, Mark J; Esterbrooks, Dennis J

    2009-11-01

    The effect of mitral regurgitation (MR) on the incidence of new cerebrovascular accidents (CVA) and mortality in patients with atrial fibrillation (AF) and left atrial thrombus (LAT) is unknown. To investigate the effect of MR in patients with AF and LAT on new CVA and mortality. Eighty nine consecutive patients, mean age 71 years, with AF and LAT documented by transesophageal echocardiography were investigated to determine the prevalence and severity of MR and the association of the severity of MR with new cerebrovascular accidents (CVA) and mortality at 34-mo follow-up. Of 89 patients, 1 + MR was present in 23 patients (26%), 2 + MR in 44 patients (50%), 3 + MR in 17 patients (19%), and 4 + MR in 3 patients (4%). Mean follow-up was 34 +/- 28 mo. The Cox proportional hazards model showed that the severity of increased MR did not significantly increase new CVA or mortality at 34-mo follow-up. The only variable predictive of mortality was left ventricular ejection fraction (LVEF), and with every unit increase in LVEF, the risk decreased by 3%. MR occurred in 87 of 89 patients (98%) with AF and LAT. There was no association between the severity of MR and the incidence of CVA or mortality.

  2. Circulating miR-423_5p fails as a biomarker for systemic ventricular function in adults after atrial repair for transposition of the great arteries.

    PubMed

    Tutarel, Oktay; Dangwal, Seema; Bretthauer, Julia; Westhoff-Bleck, Mechthild; Roentgen, Philipp; Anker, Stefan D; Bauersachs, Johann; Thum, Thomas

    2013-07-15

    Recently, the microRNA miR-423_5p was identified as a biomarker for left ventricular heart failure. Its role in patients with a systemic right ventricle and reduced ejection fraction after atrial repair for transposition of the great arteries has not been evaluated. In 41 patients and 10 age- and sex-matched healthy controls circulating miR-423_5p concentration was measured and correlated to clinical parameters, cardiac functional parameters assessed by magnetic resonance imaging, and cardiopulmonary exercise testing. Levels of circulating miR-423_5p showed no difference between patients and controls. Further, there was no correlation between miR-423_5p and parameters of cardiopulmonary exercise testing or imaging findings. In patients with a systemic right ventricle and reduced ejection fraction miR-423_5p levels are not elevated. Therefore, circulating miR-423_5p is not a useful biomarker for heart failure in this patient group. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Triple-site pacing for cardiac resynchronization in permanent atrial fibrillation - Acute phase results from a prospective observational study.

    PubMed

    Marques, Pedro; Nobre Menezes, Miguel; Lima da Silva, Gustavo; Bernardes, Ana; Magalhães, Andreia; Cortez-Dias, Nuno; Carpinteiro, Luís; de Sousa, João; Pinto, Fausto J

    2016-06-01

    Multi-site pacing is emerging as a new method for improving response to cardiac resynchronization therapy (CRT), but has been little studied, especially in patients with atrial fibrillation. We aimed to assess the effects of triple-site (Tri-V) vs. biventricular (Bi-V) pacing on hemodynamics and QRS duration. This was a prospective observational study of patients with permanent atrial fibrillation and ejection fraction <40% undergoing CRT implantation (n=40). One right ventricular (RV) lead was implanted in the apex and another in the right ventricular outflow tract (RVOT) septal wall. A left ventricular (LV) lead was implanted in a conventional venous epicardial position. Cardiac output (using the FloTrac™ Vigileo™ system), mean QRS and ejection fraction were calculated. Mean cardiac output was 4.81±0.97 l/min with Tri-V, 4.68±0.94 l/min with RVOT septal and LV pacing, and 4.68±0.94 l/min with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV). Mean pre-implantation QRS was 170±25 ms, 123±18 ms with Tri-V, 141±25 ms with RVOT septal pacing and LV pacing and 145±19 with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV and pre-implantation). Mean ejection fraction was significantly higher with Tri-V (30±11%) vs. Bi-V pacing (28±12% with RVOT septal and LV pacing and 28±11 with RV apical and LV pacing) and pre-implantation (25±8%). Tri-V pacing produced higher cardiac output and shorter QRS duration than Bi-V pacing. This may have a significant impact on the future of CRT. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  4. Two-dimensional echocardiographic estimates of left atrial function in healthy dogs and dogs with myxomatous mitral valve disease.

    PubMed

    Dickson, David; Caivano, Domenico; Matos, Jose Novo; Summerfield, Nuala; Rishniw, Mark

    2017-12-01

    To provide reference intervals for 2-dimensional linear and area-based estimates of left atrial (LA) function in healthy dogs and to evaluate the ability of estimates of LA function to differentiate dogs with subclinical myxomatous mitral valve disease (MMVD) and similarly affected dogs with congestive heart failure (CHF). Fifty-two healthy adult dogs, 88 dogs with MMVD of varying severity. Linear and area measurements from 2-dimensional echocardiographs in both right parasternal long and short axis views optimized for the left atrium were used to derive estimates of LA active emptying fraction, passive emptying fraction, expansion index, and total fractional emptying. Differences for each estimate were compared between healthy and MMVD dogs (based on ACVIM classification), and between MMVD dogs with subclinical disease and CHF that had similar LA dimensions. Diagnostic utility at identifying CHF was examined for dogs with subclinical MMVD and CHF. Relationships with bodyweight were assessed. All estimates of LA function decreased with increasing ACVIM stage of mitral valve disease (p<0.05) and showed negative relationships with increasing LA size (all r 2 values < 0.2), except for LA passive emptying fraction, which did not differ or correlate with LA size (p=0.4). However, no index of LA function identified CHF better than measurements of LA size. Total LA fractional emptying and expansion index showed modest negative correlations with bodyweight. Estimates of LA function worsen with worsening MMVD but fail to discriminate dogs with CHF from those with subclinical MMVD any better than simple estimates of LA size. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Correlation of transforming growth factor-β1 and tumour necrosis factor levels with left ventricular function in Chagas disease.

    PubMed

    Curvo, Eduardo Ov; Ferreira, Roberto R; Madeira, Fabiana S; Alves, Gabriel F; Chambela, Mayara C; Mendes, Veronica G; Sangenis, Luiz Henrique C; Waghabi, Mariana C; Saraiva, Roberto M

    2018-02-19

    Transforming growth factor β1 (TGF-β1) and tumour necrosis factor (TNF) have been implicated in Chagas disease pathophysiology and may correlate with left ventricular (LV) function. We determined whether TGF-β1 and TNF serum levels correlate with LV systolic and diastolic functions and brain natriuretic peptide (BNP) serum levels in chronic Chagas disease. This cross-sectional study included 152 patients with Chagas disease (43% men; 57 ± 12 years old), classified as 53 patients with indeterminate form and 99 patients with cardiac form (stage A: 24, stage B: 25, stage C: 44, stage D: 6). TGF-β1, TNF, and BNP were determined by enzyme-linked immunosorbent assay ELISA. Echocardiogram was used to determine left atrial and LV diameters, as well as LV ejection fraction and diastolic function. TGF-b1 serum levels were lower in stages B, C, and D, while TNF serum levels were higher in stages C and D of the cardiac form. TGF-β1 presented a weak correlation with LV diastolic function and LV ejection fraction. TNF presented a weak correlation with left atrial and LV diameters and LV ejection fraction. TNF is increased, while TGF-β1 is decreased in the cardiac form of chronic Chagas disease. TNF and TGF-β1 serum levels present a weak correlation with LV systolic and diastolic function in Chagas disease patients.

  6. Reduction of atrial fibrillation by Tanshinone IIA in chronic heart failure.

    PubMed

    He, Zhifeng; Sun, Changzheng; Xu, Yi; Cheng, Dezhi

    2016-12-01

    The aim of the present study was to confirm the effect of Tanshinone IIA (TAN) on the prevention of AF in chronic heart failure (CHF), and to elucidate the underlying electrophysiological mechanisms for the antiarrhythmic effects of TAN at the level of the atrium in an experimental model of CHF. In 10 female rabbits, CHF was induced by rapid ventricular pacing, leading to a significant decrease in ejection fraction in the presence of a dilated left ventricle and atrial enlargement. Twelve rabbits were sham-operated and served as controls. Isolated hearts were perfused using the Langendorff method. Burst pacing was used to induce AF. Monophasic action potential recordings showed an increase of atrial action potential duration (aAPD) and effective refractory period (aERP) in CHF hearts compared with sham hearts. Infusion of acetylcholine (1μm) and isoproterenol (1μm) led to AF in all failing hearts and in 11 sham hearts. Simultaneous infusion of TAN (10μm) remarkably reduced inducibility of AF in 50% of sham and 50% of failing hearts. TAN had no effect on aAPD but significantly increased aERP, leading to a marked increase in atrial post-repolarization refractoriness. Moreover, TAN application moderately increased interatrial conduction time. TAN has been shown to be effective in reducing the inducibility of AF in an experimental model of AF. The antiarrhythmic effect is mainly due to prolongations of atrial post-repolarization refractoriness and a moderate increase in interatrial conduction time. Copyright © 2016. Published by Elsevier Masson SAS.

  7. Right ventricular performance and mass by use of cine MRI late after atrial repair of transposition of the great arteries.

    PubMed

    Lorenz, C H; Walker, E S; Graham, T P; Powers, T A

    1995-11-01

    The long-term adaptation of the right ventricle after atrial repair of transposition of the great arteries (TGA) remains a subject of major concern. Cine magnetic resonance imaging (MRI), with its tomographic capabilities, allows unique quantitative evaluation of both right and left ventricular function and mass. Our purpose was to use MRI and an age-matched normal population to examine the typical late adaptation of the right and left ventricles after atrial repair of TGA. Cine MRI was used to study ventricular function and mass in 22 patients after atrial repair of TGA. Images were obtained in short-axis sections from base to apex to derive normalized right and left ventricular mass (RVM and LVM, g/m2), interventricular septal mass (IVSM, g/m2), RV and LV end-diastolic volumes (EDV, mL/m2), and ejection fractions (EF). Results 8 to 23 years after repair were compared with analysis of 24 age- and sex-matched normal volunteers and revealed markedly elevated RVM, decreased LVM and IVSM, normal RV size, and only mildly depressed RVEF. Only 1 of 22 patients had clinical RV dysfunction, and this patient had increased RVM. Cine MRI allows quantitative evaluation of both RV and LV mass and function late after atrial repair of TGA. Longitudinal studies that include these measurements should prove useful in determining the mechanism of late RV failure in these patients. On the basis of these early data, inadequate hypertrophy does not appear to be the cause of late dysfunction in this patient group.

  8. Incomplete aneurysm coverage after patent foramen ovale closure in patients with huge atrial septal aneurysm: effects on left atrial functional remodeling.

    PubMed

    Rigatelli, Gianluca; Ronco, Federico; Cardaioli, Paolo; Dell'avvocata, Fabio; Braggion, Gabriele; Giordan, Massimo; Aggio, Silvio

    2010-08-01

    Large devices are often implanted to treat patent foramen ovale (PFO) and atrial septal aneurysm (ASA) with increase risk of erosion and thrombosis. Our study is aimed to assess the impact on left atrium functional remodeling and clinical outcomes of partial coverage of the approach using moderately small Amplatzer ASD Cribriform Occluder in patients with large PFO and ASA. We prospectively enrolled 30 consecutive patients with previous stroke (mean age 36 +/- 9.5 years, 19 females), significant PFO, and large ASA referred to our center for catheter-based PFO closure. Left atrium (LA) passive and active emptying, LA conduit function, and LA ejection fraction were computed before and after 6 months from the procedure by echocardiography. The preclosure values were compared to values of a normal healthy population of sex and heart rate matched 30 patients. Preclosure values demonstrated significantly greater reservoir function as well as passive and active emptying, with significantly reduced conduit function and LA ejection fraction, when compared normal healthy subjects. All patients underwent successful transcatheter closure (25 mm device in 15 patients, 30 mm device in 6 patients, mean ratio device/diameter of the interatrial septum = 0.74). Incomplete ASA coverage in both orthogonal views was observed in 21 patients. Compared to patients with complete coverage, there were no differences in LA functional parameters and occlusion rates. This study confirmed that large ASAs are associated with LA dysfunction. The use of relatively small Amplatzer ASD Cribriform Occluder devices is probably effective enough to promote functional remodeling of the left atrium.

  9. In vivo evaluation of virtual electrode mapping and ablation utilizing a direct endocardial visualization ablation catheter.

    PubMed

    Chik, William W B; Barry, M A; Malchano, Zach; Wylie, Bryan; Pouliopoulos, Jim; Huang, Kaimin; Lu, Juntang; Thavapalachandran, Sujitha; Robinson, David; Saadat, Vahid; Thomas, Stuart P; Ross, David L; Kovoor, Pramesh; Thiagalingam, Aravinda

    2012-01-01

    Radiofrequency (RF) ablation utilizing direct endocardial visualization (DEV) requires a "virtual electrode" to deliver RF energy while preserving visualization. This study aimed to: (1) examine the virtual electrode RF ablation efficacy; (2) determine the optimal power and duration settings; and (3) evaluate the utility of virtual electrode unipolar electrograms. The DEV catheter lesions were compared to lesions formed using a 3.5 mm open irrigated tip catheter within the right atria of 12 sheep. Generator power settings for DEV were titrated from 12W, 14W and 16W for 20, 30 and 40 seconds duration with 25 mL/min saline irrigation. Standard irrigated tip catheter settings of 30W, 50°C for 30 seconds and 30 mL/min were used. The DEV lesions were significantly greater in surface area and both major and minor axes compared to irrigated tip lesions (surface area 19.43 ± 9.09 vs 10.88 ± 4.72 mm, P<0.01) with no difference in transmurality (93/94 vs 46/47) or depth (1.86 ± 0.75 vs 1.85 ± 0.57 mm). Absolute electrogram amplitude reduction was greater for DEV lesions (1.89 ± 1.31 vs 1.49 ± 0.78 mV, P = 0.04), but no difference in percentage reduction. Pre-ablation pacing thresholds were not different between DEV (0.79 ± 0.36 mA) and irrigated tip (0.73 ± 0.25 mA) lesions. There were no complications noted during ablation with either catheter. Virtual electrode ablation consistently created wider lesions at lower power compared to irrigated tip ablation. Virtual electrode electrograms showed a comparable pacing and sensing efficacy in detecting local myocardial electrophysiological changes. © 2011 Wiley Periodicals, Inc.

  10. Comparison of the clinical utility of atrial and B type natriuretic peptide measurement for the diagnosis of systolic dysfunction in a low‐risk population

    PubMed Central

    Galasko, Gavin; Collinson, Paul O; Barnes, Sophie C; Gaze, David; Lahiri, Arjivit; Senior, Roxy

    2007-01-01

    Background Measurement of B type natriuretic peptide and its N terminal prohormone (NTproBNP) can now be performed routinely by automated high‐throughput immunoassays. The study compared measurement of NTproBNP with measurement of N terminal pro‐atrial natriuretic peptide (NTproANP) for detection of ventricular systolic dysfunction in primary care. Methods 734 subjects aged >45 years (349 men and 385 women, median age 58 years, range 45–89, interquartile range 51–67 years) from seven representative general practices attended for echocardiography with determination of ejection fraction and completed a questionnaire. Blood samples were collected into gel serum separation tubes (Becton–Dickinson, Franklin Lakes, New Jersey, USA), the serum separated and aliquots stored frozen at −70°C until analyses. Samples were analysed for NTproBNP (Roche Diagnostics, Lewes, UK; coefficient of variation (CV) 3.2–2.4%) and for NTproANP (Biomedica, Vienna, Austria; CV 5.6–10.1%). Echocardiography was used as the diagnostic “gold standard”, with ventricular systolic dysfunction defined as abnormal when there was an ejection fraction of ⩽40%. Patients were dichotomised by ejection fraction from 50% to 30%, and receiver operating characteristic curves constructed and the area under the curve (AUC) compared. Results At 40% ejection fraction, NTproANP and NTproBNP showed AUCs of, respectively, 0.738 (0.601–0.875) and 0.973 (0.958–0.989), p<0.004. Conclusion NTproBNP is superior to NTproANP for detection of systolic dysfunction. PMID:17513518

  11. Cardiac structure and function in Cushing's syndrome: a cardiac magnetic resonance imaging study.

    PubMed

    Kamenický, Peter; Redheuil, Alban; Roux, Charles; Salenave, Sylvie; Kachenoura, Nadjia; Raissouni, Zainab; Macron, Laurent; Guignat, Laurence; Jublanc, Christel; Azarine, Arshid; Brailly, Sylvie; Young, Jacques; Mousseaux, Elie; Chanson, Philippe

    2014-11-01

    Patients with Cushing's syndrome have left ventricular (LV) hypertrophy and dysfunction on echocardiography, but echo-based measurements may have limited accuracy in obese patients. No data are available on right ventricular (RV) and left atrial (LA) size and function in these patients. The objective of the study was to evaluate LV, RV, and LA structure and function in patients with Cushing's syndrome by means of cardiac magnetic resonance, currently the reference modality in assessment of cardiac geometry and function. Eighteen patients with active Cushing's syndrome and 18 volunteers matched for age, sex, and body mass index were studied by cardiac magnetic resonance. The imaging was repeated in the patients 6 months (range 2-12 mo) after the treatment of hypercortisolism. Compared with controls, patients with Cushing's syndrome had lower LV, RV, and LA ejection fractions (P < .001 for all) and increased end-diastolic LV segmental thickness (P < .001). Treatment of hypercortisolism was associated with an improvement in ventricular and atrial systolic performance, as reflected by a 15% increase in the LV ejection fraction (P = .029), a 45% increase in the LA ejection fraction (P < .001), and an 11% increase in the RV ejection fraction (P = NS). After treatment, the LV mass index and end-diastolic LV mass to volume ratio decreased by 17% (P < .001) and 10% (P = .002), respectively. None of the patients had late gadolinium myocardial enhancement. Cushing's syndrome is associated with subclinical biventricular and LA systolic dysfunctions that are reversible after treatment. Despite skeletal muscle atrophy, Cushing's syndrome patients have an increased LV mass, reversible upon correction of hypercortisolism.

  12. Spinal cord activation differentially modulates ischaemic electrical responses to different stressors in canine ventricles.

    PubMed

    Cardinal, René; Ardell, Jeffrey L; Linderoth, Bengt; Vermeulen, Michel; Foreman, Robert D; Armour, J Andrew

    2004-03-31

    Spinal cord stimulation (SCS) represents an acceptable treatment modality for patients with chronic angina pectoris refractory to standard therapy, but its mechanism of action remains unclear. To develop an experimental paradigm to study this issue, ameroid (AM) constrictors were implanted around the left circumflex coronary artery (LCx) in canines. Six weeks later, unipolar electrograms were recorded from 191 sites in the LCx territory in the open-chest, anesthetized state under basal pacing at 150 beats/min. We investigated the effect of SCS on ST segment displacements induced in the collateral-dependent myocardium in response to two stressors: (i) transient bouts of rapid ventricular pacing (TRP: 240/min for 1 min) and (ii) angiotensin II administered to right atrial neurons via their coronary artery blood supply. ST segment responses to TRP consisted of ST segment elevation in central areas of the LCx territory and ST depression at more peripheral areas. Such responses were unchanged when TRP was applied under SCS. Shortening of repolarization intervals in the metabolically compromised myocardium in response to TRP was also unaffected by SCS. In contrast, ST segment responses to intracoronary angiotensin II, which consisted of increased ST elevation, were attenuated by SCS in 6/8 preparations. The modulator effects of SCS were greatest at sites at which the greatest responses to angiotensin II occurred in the absence of SCS. These data indicate that spinal cord stimulation may attenuate the deleterious effects that stressors exert on the myocardium with reduced coronary reserve, particularly stressors associated with chemical activation of the intrinsic cardiac nervous system. Copyright 2004 Elsevier B.V.

  13. Association between left atrial function assessed by speckle-tracking echocardiography and the presence of left atrial appendage thrombus in patients with atrial fibrillation.

    PubMed

    Kupczynska, Karolina; Michalski, Blazej W; Miskowiec, Dawid; Kasprzak, Jaroslaw D; Wejner-Mik, Paulina; Wdowiak-Okrojek, Katarzyna; Lipiec, Piotr

    2017-07-01

    The aim of the study was to investigate whether the deformation of left atrium (LA) measured by speckle-tracking analysis (STE) is associated with the presence of LA appendage thrombus (LAAT) during non-valvular atrial fibrillation (AF). Eighty-seven patients (mean age 67 years, 59% men) were included to retrospective cross-sectional study. On top of standard echocardiography we assessed: LA longitudinal systolic strain (LS), systolic (LSSR) and early diastolic strain rate (LESR) in four-chamber and twochamber apical views. All patients underwent transesophageal echocardiography disclosing LAAT in 36 (41%) patients. Subgroups with and without thrombi did not differ with regard to clinical characteristics. Univariate factors associated with LAAT were as follows: CH2ADS2-VASc Score, left ventricular ejection fraction (LVEF), LV mass, and STE measurements. In a multivariate model only LVEF (p=0.002), LS (p=0.02), LESR (p=0.008), and LSSR (p=0.045) were independently associated with LAAT presence. Moreover, LVEF and LA STE measurements provided incremental value over the CH2ADS2-VASc Score. Speckle-tracking TTE may be used to describe LA reservoir and conduit function during AF, allowing the identification of patients with higher risk of LAAT and providing incremental value over the CH2ADS2-VASc Score.

  14. VLDL from Metabolic Syndrome Individuals Enhanced Lipid Accumulation in Atria with Association of Susceptibility to Atrial Fibrillation.

    PubMed

    Lee, Hsiang-Chun; Lin, Hsin-Ting; Ke, Liang-Yin; Wei, Chi; Hsiao, Yi-Lin; Chu, Chih-Sheng; Lai, Wen-Ter; Shin, Shyi-Jang; Chen, Chu-Huang; Sheu, Sheng-Hsiung; Wu, Bin-Nan

    2016-01-20

    Metabolic syndrome (MetS) represents a cluster of metabolic derangements. Dyslipidemia is an important factor in MetS and is related to atrial fibrillation (AF). We hypothesized that very low density lipoproteins (VLDL) in MetS (MetS-VLDL) may induce atrial dilatation and vulnerability to AF. VLDL was therefore separated from normal (normal-VLDL) and MetS individuals. Wild type C57BL/6 male mice were divided into control, normal-VLDL (nVLDL), and MetS-VLDL (msVLDL) groups. VLDL (15 µg/g) and equivalent volumes of saline were injected via tail vein three times a week for six consecutive weeks. Cardiac chamber size and function were measured by echocardiography. MetS-VLDL significantly caused left atrial dilation (control, n = 10, 1.64 ± 0.23 mm; nVLDL, n = 7, 1.84 ± 0.13 mm; msVLDL, n = 10, 2.18 ± 0.24 mm; p < 0.0001) at week 6, associated with decreased ejection fraction (control, n = 10, 62.5% ± 7.7%, vs. msVLDL, n = 10, 52.9% ± 9.6%; p < 0.05). Isoproterenol-challenge experiment resulted in AF in young msVLDL mice. Unprovoked AF occurred only in elderly msVLDL mice. Immunohistochemistry showed excess lipid accumulation and apoptosis in msVLDL mice atria. These findings suggest a pivotal role of VLDL in AF pathogenesis for MetS individuals.

  15. Association between atrial fibrillation, atrial enlargement, and left ventricular geometric remodeling.

    PubMed

    Seko, Yuta; Kato, Takao; Haruna, Tetsuya; Izumi, Toshiaki; Miyamoto, Shoichi; Nakane, Eisaku; Inoko, Moriaki

    2018-04-23

    This study investigated the relationship between atrial fibrillation (AF) and left ventricular (LV) geometric patterns in a hospital-based population in Japan. We retrospectively analyzed 4444 patients who had undergone simultaneous scheduled transthoracic echocardiography (TTE) and electrocardiography during 2013. A total of 430 patients who had findings of previous myocardial infarctions (n = 419) and without the data on body surface area (n = 11) were excluded from the study. We calculated the LV mass index (LVMI) and relative wall (RWT) and categorized 4014 patients into four groups as follows: normal geometry (n = 3046); concentric remodeling (normal LVMI and high RWT, n = 437); concentric hypertrophy (high LVMI and high RWT, n = 149); and eccentric remodeling (high LVMI and normal RWT, n = 382). The mean left atrial volume indices (LAVI) were 22.5, 23.8, 33.3, and 37.0 mm/m 2 in patients with normal geometry, concentric remodeling, concentric hypertrophy, and eccentric hypertrophy, respectively. The mean LV ejection fractions (LVEF) were 62.7, 62.6, 60.8, and 53.8%, respectively, whereas the prevalence of AF was 10.4%, 10.5%, 14.8%, and 16.8% in patients with normal geometry, concentric remodeling, concentric hypertrophy, and eccentric hypertrophy, respectively. In conclusion, the prevalence of AF was increasing according to LV geometric remodeling patterns in association with LA size and LVEF.

  16. Left atrial function to identify patients with atrial fibrillation at high risk of stroke: new insights from a large registry.

    PubMed

    Leung, Melissa; van Rosendael, Philippe J; Abou, Rachid; Ajmone Marsan, Nina; Leung, Dominic Y; Delgado, Victoria; Bax, Jeroen J

    2018-04-21

    Atrial fibrillation (AF) is an independent risk factor for ischaemic stroke. The CHA2DS2-VASc is the most widely used risk stratification model; however, echocardiographic refinement may be useful, particularly in low risk AF patients. The present study examined the association between advanced echocardiographic parameters and ischaemic stroke, independent of CHA2DS2-VASc score. One thousand, three hundred and sixty-one patients (mean age 65±12 years, 74% males) with first diagnosis of AF and baseline transthoracic echocardiogram were followed by chart review for the occurrence of stroke over a mean of 7.9 years. Left atrial (LA) volumes, LA reservoir strain, P-wave to A' duration on tissue Doppler imaging (PA-TDI, reflecting total atrial conduction time), and left ventricular (LV) global longitudinal strain (GLS) were evaluated in patients with and without stroke. The independent association of these echocardiographic parameters with the occurrence of ischaemic stroke was evaluated with Cox proportional hazard models. One-hundred patients (7%) developed an ischaemic stroke, representing an annualized stroke rate of 0.9%. The incident stroke rate in the year following the first diagnosis of AF was 2.6% in the entire population and higher than the remainder of the follow-up period. Left atrial reservoir (14.5% vs. 18.9%, P = 0.005) and conduit strains were reduced (10.5% vs. 13.5%, P = 0.013), and PA-TDI lengthened (166 ms vs. 141 ms, P < 0.001) in the stroke compared with non-stroke group, despite similar LV dimensions, LV ejection fraction, GLS, and LA volumes. Left atrial reservoir strain and PA-TDI were independently associated with risk of stroke in a model including CHA2DS2-VASc score, age, and anticoagulant use. The assessment of LA reservoir strain and PA-TDI on echocardiography after initial CHA2DS2-VASc scoring provides additional risk stratification for stroke and may be useful to guide decisions regarding anticoagulation for patients upon first diagnosis of AF.

  17. Beyond long memory in heart rate variability: An approach based on fractionally integrated autoregressive moving average time series models with conditional heteroscedasticity

    NASA Astrophysics Data System (ADS)

    Leite, Argentina; Paula Rocha, Ana; Eduarda Silva, Maria

    2013-06-01

    Heart Rate Variability (HRV) series exhibit long memory and time-varying conditional variance. This work considers the Fractionally Integrated AutoRegressive Moving Average (ARFIMA) models with Generalized AutoRegressive Conditional Heteroscedastic (GARCH) errors. ARFIMA-GARCH models may be used to capture and remove long memory and estimate the conditional volatility in 24 h HRV recordings. The ARFIMA-GARCH approach is applied to fifteen long term HRV series available at Physionet, leading to the discrimination among normal individuals, heart failure patients, and patients with atrial fibrillation.

  18. Atrial function as a guide to timing of intervention in mitral valve prolapse with mitral regurgitation.

    PubMed

    Ring, Liam; Rana, Bushra S; Wells, Francis C; Kydd, Anna C; Dutka, David P

    2014-03-01

    The purpose of this study was to determine the clinical utility of left atrial (LA) functional indexes in patients with mitral valve prolapse (MVP) and mitral regurgitation (MR). Timing of surgery for MVP remains challenging. We hypothesized that assessment of LA function may provide diagnostic utility in these patients. We studied 192 consecutive patients in sinus rhythm with MVP, classified into 3 groups: moderate or less MR (MOD group, n = 54); severe MR without surgical indication (SEV group, n = 52); and severe MR with ≥1 surgical indication (SURG group, n = 86). Comparison was made with 50 control patients. Using 2D speckle imaging, average peak contractile, conduit, and reservoir atrial strain was recorded. Using Simpson's method we recorded maximal left atrial volume (LAVmax) and minimal left atrial volume (LAVmin), from which the total left atrial emptying fraction (TLAEF) was derived: (LAVmax-LAVmin)/LAVmax × 100%. TLAEF was similar in the MOD and control groups (61% vs. 57%; p = NS), was reduced in the SEV group (55%; p < 0.001 vs. control group), and markedly lower in the SURG group (40%; p < 0.001 vs. other groups). Reservoir strain demonstrated a similar pattern. Contractile strain was similarly reduced in the MOD and SEV groups (MOD 15%; SEV 14%; p = NS; both p < 0.05 vs. control group 20%) and further reduced in the SURG group (8%; p < 0.001 vs. other groups). By multivariate analysis, TLAEF (odds ratio [OR]: 0.78; p < 0.001), reservoir strain (OR: 0.91; p = 0.028), and contractile strain (OR: 0.86; p = 0.021) were independent predictors of severe MR requiring surgery. Using receiver-operating characteristic analysis, TLAEF <50% demonstrated 91% sensitivity and 92% specificity for predicting MVP with surgical indication (area under the curve: 0.96; p < 0.001). We report the changes in left atrial function in humans with MVP and the relationship of LA dysfunction to clinical indications for mitral valve surgery. We propose that the findings support the utility of quantitative assessment of atrial function by echocardiography as an additional tool to guide the optimum timing of surgery for MVP. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Noninvasive evaluation of reverse atrial remodeling after catheter ablation of atrial fibrillation by P wave dispersion.

    PubMed

    Fujimoto, Yuhi; Yodogawa, Kenji; Takahashi, Kenta; Tsuboi, Ippei; Hayashi, Hiroshi; Uetake, Shunsuke; Iwasaki, Yu-Ki; Hayashi, Meiso; Miyauchi, Yasushi; Shimizu, Wataru

    2017-11-01

    Atrial fibrillation (AF) itself creates structural and electrophysiological changes such as atrial enlargement, shortening of refractory period and decrease in conduction velocity, called "atrial remodeling", promoting its persistence. Although the remodeling process is considered to be reversible, it has not been elucidated in detail. The aim of this study was to assess the feasibility of P wave dispersion in the assessment of reverse atrial remodeling following catheter ablation of AF. Consecutive 126 patients (88 males, age 63.0 ± 10.4 years) who underwent catheter ablation for paroxysmal AF were investigated. P wave dispersion was calculated from the 12 lead ECG before, 1 day, 1 month, 3 months and 6 months after the procedure. Left atrial diameter (LAD), left atrial volume index (LAVI), left ventricular ejection fraction (LVEF), transmitral flow velocity waveform (E/A), and tissue Doppler (E/e') on echocardiography, plasma B-type natriuretic peptide (BNP) concentrations, serum creatinine, and estimated glomerular filtration rate (eGFR) were also measured. Of all patients, 103 subjects remained free of AF for 1 year follow-up. In these patients, P wave dispersion was not changed 1 day and 1 month after the procedure. However, it was significantly decreased at 3 and 6 months (50.1 ± 14.8 to 45.4 ± 14.4 ms, p < 0.05, 45.2 ± 9.9 ms, p < 0.05, respectively). Plasma BNP concentrations, LAD and LAVI were decreased (81.1 ± 103.8 to 44.8 ± 38.3 pg/mL, p < 0.05, 38.2 ± 5.7 to 35.9 ± 5.6 mm, p < 0.05, 33.3 ± 14.2 to 29.3 ± 12.3 mL/m 2 , p < 0.05) at 6 months after the procedure. There were no significant changes in LVEF, E/A, E/e', serum creatinine, and eGFR during the follow up period. P wave dispersion was decreased at 3 and 6 months after catheter ablation in patients without recurrence of AF. P wave dispersion is useful for assessment of reverse remodeling after catheter ablation of AF.

  20. A genotype-directed comparative effectiveness trial of Bucindolol and metoprolol succinate for prevention of symptomatic atrial fibrillation/atrial flutter in patients with heart failure: Rationale and design of the GENETIC-AF trial.

    PubMed

    Piccini, Jonathan P; Connolly, Stuart J; Abraham, William T; Healey, Jeff S; Steinberg, Benjamin A; Al-Khalidi, Hussein R; Dignacco, Patricia; van Veldhuisen, Dirk J; Sauer, William H; White, Michel; Wilton, Stephen B; Anand, Inder S; Dufton, Christopher; Marshall, Debra A; Aleong, Ryan G; Davis, Gordon W; Clark, Richard L; Emery, Laura L; Bristow, Michael R

    2018-05-01

    Few therapies are available for the safe and effective treatment of atrial fibrillation (AF) in patients with heart failure. Bucindolol is a non-selective beta-blocker with mild vasodilator activity previously found to have accentuated antiarrhythmic effects and increased efficacy for preventing heart failure events in patients homozygous for the major allele of the ADRB1 Arg389Gly polymorphism (ADRB1 Arg389Arg genotype). The safety and efficacy of bucindolol for the prevention of AF or atrial flutter (AFL) in these patients has not been proven in randomized trials. The Genotype-Directed Comparative Effectiveness Trial of Bucindolol and Metoprolol Succinate for Prevention of Symptomatic Atrial Fibrillation/Atrial Flutter in Patients with Heart Failure (GENETIC-AF) trial is a multicenter, randomized, double-blinded "seamless" phase 2B/3 trial of bucindolol hydrochloride versus metoprolol succinate, for the prevention of symptomatic AF/AFL in patients with reduced ejection fraction heart failure (HFrEF). Patients with pre-existing HFrEF and recent history of symptomatic AF are eligible for enrollment and genotype screening, and if they are ADRB1 Arg389Arg, eligible for randomization. A total of approximately 200 patients will comprise the phase 2B component and if pre-trial assumptions are met, 620 patients will be randomized at approximately 135 sites to form the Phase 3 population. The primary endpoint is the time to recurrence of symptomatic AF/AFL or mortality over a 24-week follow-up period, and the trial will continue until 330 primary endpoints have occurred. GENETIC-AF is the first randomized trial of pharmacogenetic guided rhythm control, and will test the safety and efficacy of bucindolol compared with metoprolol succinate for the prevention of recurrent symptomatic AF/AFL in patients with HFrEF and an ADRB1 Arg389Arg genotype. (ClinicalTrials.govNCT01970501). Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Does permanent atrial fibrillation modify response to cardiac resynchronization therapy in heart failure patients?

    PubMed

    Abreu, Ana; Oliveira, Mário; Silva Cunha, Pedro; Santa Clara, Helena; Portugal, Guilherme; Gonçalves Rodrigues, Inês; Santos, Vanessa; Morais, Luís; Selas, Mafalda; Soares, Rui; Branco, Luísa; Ferreira, Rui; Mota Carmo, Miguel

    2017-10-01

    The benefits of cardiac resynchronization therapy (CRT) documented in heart failure (HF) may be influenced by atrial fibrillation (AF). We aimed to compare CRT response in patients in AF and in sinus rhythm (SR). We prospectively studied 101 HF patients treated by CRT. Rates of clinical, echocardiographic and functional response, baseline NYHA class and variation, left ventricular ejection fraction, volumes and mass, atrial volumes, cardiopulmonary exercise test (CPET) duration (CPET dur), peak oxygen consumption (VO 2 max) and ventilatory efficiency (VE/VCO 2 slope) were compared between AF and SR patients, before and at three and six months after implantation of a CRT device. All patients achieved ≥95% biventricular pacing, and 5.7% underwent atrioventricular junction ablation. Patients were divided into AF (n=35) and SR (n=66) groups; AF patients were older, with larger atrial volumes and lower CPET dur and VO 2 max before CRT. The percentages of clinical and echocardiographic responders were similar in the two groups, but there were more functional responders in the AF group (71% vs. 39% in SR patients; p=0.012). In SR patients, left atrial volume and left ventricular mass were significantly reduced (p=0.015 and p=0.021, respectively), whereas in AF patients, CPET dur (p=0.003) and VO 2 max (p=0.001; 0.083 age-adjusted) showed larger increases. Clinical and echocardiographic response rates were similar in SR and AF patients, with a better functional response in AF. Improvement in left ventricular function and volumes occurred in both groups, but left ventricular mass reduction and left atrial reverse remodeling were seen exclusively in SR patients (ClinicalTrials.gov identifier: NCT02413151; FCT code: PTDC/DES/120249/2010). Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Usefulness of the brain natriuretic peptide to atrial natriuretic peptide ratio in determining the severity of mitral regurgitation.

    PubMed

    Shimamoto, Ken; Kusumoto, Miyako; Sakai, Rieko; Watanabe, Hirota; Ihara, Syunichi; Koike, Natsuka; Kawana, Masatoshi

    2007-03-15

    Atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) levels were characterized in subjects with mitral regurgitation (MR). Sixty-two cases of moderate or severe chronic MR were studied. The blood levels of neurohormonal factors were stratified by the known MR prognostic factors of New York Heart Association (NYHA) functional class, left ventricular end-diastolic diameters, left ventricular end-systolic diameter (LVDs), ejection fraction (EF), left atrial diameter and presence of atrial fibrillation (AF). ANP levels were higher in NYHA class II and lower in classes I and III/IV (P=0.0206). BNP levels were higher in NYHA class II than class I (P=0.0355). The BNP/ANP ratio was significantly higher in NYHA classes II and III/IV than in class I (P=0.0007). To differentiate between NYHA classes I/II and III/IV, a cut-off BNP/ANP ratio of 2.97 produced a sensitivity of 78% and specificity of 87%. Compared with subjects in sinus rhythm, patients with AF had an enlarged left atrium and lower ANP levels. The BNP/ANP ratio correlated significantly with left atrial diameter, LVDs and EF (r=0.429, P=0.0017; r=0.351, P=0.0117; and r=-0.349, P=0.0122; respectively), and was significantly higher among all the known operative indications for MR tested (LVDs 45 mm or more, EF 60% or less, NYHA class II or greater and AF; P=0.0073, P=0.003, P=0.0102 and P=0.0149, respectively). In chronic MR, levels of ANP and BNP, and the BNP/ANP ratio are potential indicators of disease severity.

  3. [Plasma cardiac natriuretic peptide as a biological marker of recurrence of atrial fibrillation in elderly people].

    PubMed

    Mabuchi, N; Tsutamoto, T; Maeda, K; Masahiko, K

    2000-07-01

    We designed this study to evaluate the relationship between plasma atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) levels and recurrence of atrial fibrillation (AF) after direct current cardioversion (DC) and the differences with aging. Fifty patients with mild congestive heart failure (CHF) undergoing elective DC of AF were included in this study (New York Heart Association (NYHA) functional class II: n = 42, III = 8). Patients who failed to show restoration of sinus rhythm or those with mitral valve stenosis were excluded. Before successful DC, we measured plasma levels of ANP and BNP and evaluated left atrial dimension (LAD), left ventricular end-diastolic dimension (LVDd), and left ventricular ejection fraction (EF) by echocardiography. Twenty-one patients had recurrence of AF within 2 months after DC (average 9.05 days). We followed up the other 29 patients for 580.5 days. By Cox stepwise multivariate analysis, history of AF (p = 0.007), low plasma levels of ANP (p = 0.003), and high plasma levels of BNP (p = 0.0003) were found to be independent predictors of recurrent AF. High plasma BNP levels indicating ventricular dysfunction and low plasma ANP levels may be due to atrial histological change such as fibrosis. In these patients, plasma ratios of ANP and BNP (ANP/BNP) less than 0.43 were predictive factors for AF recurrence (sensitivity 70%, specificity 62%), especially in patients who were older than 70 years (sensitivity 100%, specificity 80%). Relatively low plasma ANP level compared to BNP is an independent risk factor of AF recurrence in patients with CHF, especially in elderly patients, suggesting that plasma cardiac natriuretic peptides are important biochemical markers of AF recurrence in elderly patients with CHF.

  4. Three-dimensional speckle tracking echocardiography allows detailed evaluation of left atrial function in hypertrophic cardiomyopathy--insights from the MAGYAR-Path Study.

    PubMed

    Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila

    2014-11-01

    Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P < 0.0001) and minimum (39.2 ± 19.1 vs. 16.0 ± 4.6 mL, P < 0.0001) volumes and LA volume before atrial contraction (53.6 ± 19.9 vs. 24.0 ± 6.2 mL, P < 0.0001) were significantly increased in HCM patients. Atrial stroke volumes respecting cardiac cycles proved to be increased, while emptying fractions were decreased in subjects with HCM. Mean global radial (-12.2 ± 6.7% vs. -19.6 ± 11.7, P < 0.05), longitudinal (26.5 ± 16.5% vs. 29.8 ± 12.1%, P < 0.05) and 3D strain (-6.1 ± 4.4% vs. -12.5 ± 10.2%, P < 0.05) proved to be significantly reduced in HCM patients as compared with matched controls. Three-dimensional speckle tracking echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.

  5. Clinical and electrocardiographic characteristics for prediction of new-onset atrial fibrillation in asymptomatic patients with atrial premature complexes.

    PubMed

    Im, Sung Il; Park, Dong Hyun; Kim, Bong Joon; Cho, Kyoung Im; Kim, Hyun Su; Heo, Jung Ho

    2018-06-01

    Identification of precursors of atrial fibrillation (AF) may lead to early detection and prevent associated morbidity and mortality. Atrial premature complexes (APCs) are commonly seen in healthy subjects. However, there was limited data about the clinical and electrocardiographic (ECG) characteristics for prediction of new-onset AF in asymptomatic patients with APCs in the long-term follow up. The Kosin University (No. 2014-02-04) 24-h holter monitoring, echocardiography, ECG database were reviewed from 2008 to 2016 to identify new- onset AF in patients with APCs. We analyzed demographic and clinical features and the nature of the APCs by ECG according to new-onset AF in those patients. Among 652 patients who underwent 24-h holter monitoring, 226 (34.4%) patients had new-onset AF. There was no difference of the baseline characteristics between new-onset AF group and non-AF group. In univariate analysis, hypertension (HTN), renal failure (CRF), high APC burdens, fastest APC running heart rate (HR), minimal HR, left ventricular ejection fraction (LVEF), left atrial volume index, peak mitral flow velocity of the early rapid filling wave and tricuspid regurgitation grade were significantly associated with new-onset AF. In multivariate analysis, higher APCs burden ( P  = 0.047), higher fastest APCs running HR ( P  = 0.034) and lower minimal HR ( P  = 0.025) were independent risk factors for new-onset AF in asymptomatic patients with APCs. Higher APCs burden, higher fastest APCs running HR and lower minimal HR were associated with new-onset AF in asymptomatic patients with APCs in the long-term follow up.

  6. Right Atrial Deformation in Predicting Outcomes in Pediatric Pulmonary Hypertension.

    PubMed

    Jone, Pei-Ni; Schäfer, Michal; Li, Ling; Craft, Mary; Ivy, D Dunbar; Kutty, Shelby

    2017-12-01

    Elevated right atrial (RA) pressure is a risk factor for mortality, and RA size is prognostic of adverse outcomes in pulmonary hypertension (PH). There is limited data on phasic RA function (reservoir, conduit, and pump) in pediatric PH. We sought to evaluate (1) the RA function in pediatric PH patients compared with controls, (2) compare the RA deformation indices with Doppler indices of diastolic dysfunction, functional capacity, biomarkers, invasive hemodynamics, and right ventricular functional indices, and (3) evaluate the potential of RA deformation indices to predict clinical outcomes. Sixty-six PH patients (mean age 7.9±4.7 years) were compared with 36 controls (7.7±4.4 years). RA and right ventricular deformation indices were obtained using 2-dimensional speckle tracking (2DCPA; TomTec, Germany). RA strain, strain rates, emptying fraction, and right ventricular longitudinal strain were measured. RA function was impaired in PH patients versus controls ( P <0.001). There were significant associations between RA function with invasive hemodynamics ( P <0.01). RA reservoir, pump function, the rate of RA filling, and atrial minimum volume predicted adverse clinical outcomes (hazard ratio [HR], 0.15; confidence interval [CI], 0.03-0.73; P <0.01; HR, 0.05; CI, 0.003-0.43; P <0.004; HR, 0.04; CI, 0.006-0.56; P <0.01; and HR, 8.6; CI, 1.6-37.2; P <0.01, respectively). RA deformation properties are significantly altered in pediatric PH patients. Progressive worsening of RA reservoir and conduit functions is related to changes in right ventricular diastolic dysfunction. RA reservoir function, pump function, the rate of atrial filling, and atrial minimum volume emerged as outcome predictors in pediatric PH. © 2017 American Heart Association, Inc.

  7. [Measurement of left atrial and ventricular volumes in real-time 3D echocardiography. Validation by nuclear magnetic resonance

    NASA Technical Reports Server (NTRS)

    Bauer, F.; Shiota, T.; Qin, J. X.; White, R. D.; Thomas, J. D.

    2001-01-01

    The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.

  8. Associations of electrocardiographic P-wave characteristics with left atrial function, and diffuse left ventricular fibrosis defined by cardiac magnetic resonance: The PRIMERI Study.

    PubMed

    Tiffany Win, Theingi; Ambale Venkatesh, Bharath; Volpe, Gustavo J; Mewton, Nathan; Rizzi, Patricia; Sharma, Ravi K; Strauss, David G; Lima, Joao A; Tereshchenko, Larisa G

    2015-01-01

    Abnormal P-terminal force in lead V1 (PTFV1) is associated with an increased risk of heart failure, stroke, atrial fibrillation, and death. Our goal was to explore associations of left ventricular (LV) diffuse fibrosis with left atrial (LA) function and electrocardiographic (ECG) measures of LA electrical activity. Patients without atrial fibrillation (n = 91; mean age 59.5 years; 61.5% men; 65.9% white) with structural heart disease (spatial QRS-T angle ≥105° and/or Selvester QRS score ≥5 on ECG) but LV ejection fraction >35% underwent clinical evaluation, cardiac magnetic resonance, and resting ECG. LA function indices were obtained by multimodality tissue tracking using 2- and 4-chamber long-axis images. T1 mapping and late gadolinium enhancement were used to assess diffuse LV fibrosis and presence of scar. P-prime in V1 amplitude (PPaV1) and duration (PPdV1), averaged P-wave-duration, PR interval, and P-wave axis were automatically measured using 12 SLTM algorithm. PTFV1 was calculated as a product of PPaV1 and PPdV1. In linear regression after adjustment for demographic characteristics, body mass index, maximum LA volume index, presence of scar, and LV mass index, each decile increase in LV interstitial fibrosis was associated with 0.76 mV*ms increase in negative abnormal PTFV1 (95% confidence interval [CI] -1.42 to -0.09; P = .025), 15.3 ms prolongation of PPdV1 (95% CI 6.9 to 23.8; P = .001) and 5.4 ms prolongation of averaged P-duration (95% CI 0.9-10.0; P = .020). LV fibrosis did not affect LA function. PPaV1 and PTFV1 were associated with an increase in LA volumes and decrease in LA emptying fraction and LA reservoir function. LV interstitial fibrosis is associated with abnormal PTFV1, prolonged PPdV1, and P-duration, but does not affect LA function. Copyright © 2015 Heart Rhythm Society. All rights reserved.

  9. Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease.

    PubMed

    van den Hoven, Allard T; Mc-Ghie, Jackie S; Chelu, Raluca G; Duijnhouwer, Anthonie L; Baggen, Vivan J M; Coenen, Adriaan; Vletter, Wim B; Dijkshoorn, Marcel L; van den Bosch, Annemien E; Roos-Hesselink, Jolien W

    2017-12-01

    Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson's r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson's r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality.

  10. The reduction of central sleep apnoea severity in the left lateral position is not due to an improvement in cardiac haemodynamics in patients with chronic heart failure.

    PubMed

    Traversi, Egidio; Rossi, Davide; Maestri, Roberto; Olmetti, Francesca; La Rovere, Maria Teresa; Pinna, Gian Domenico

    2017-06-01

    The severity of central sleep apnoea (CSA), a common comorbidity in patients with chronic heart failure (CHF) and reduced ejection fraction, markedly decreases from the supine to the lateral sleeping position, with no difference between the left and right positions. The mechanisms responsible for this beneficial effect have not yet been elucidated. We tested the hypothesis that CSA attenuation in the left lateral position is due, at least in part, to an improvement in cardiac haemodynamics. Sixteen CHF patients (male, aged 60 ± 7 years, New York Heart Association class 2.6 ± 0.5, left ventricular ejection fraction [LVEF] 30% ± 5%) with moderate-to-severe CSA underwent two consecutive tissue Doppler echocardiography examinations in random order, one in the left lateral position (90°) and the other in the supine position (0°). The following parameters were obtained: left ventricular end-diastolic volume (LVEDV) and LVEF, left atrial volume (LAV) and right atrial volume (RAV), mitral regurgitation (MR), cardiac output (CO), transmitral protodiastolic (E) wave deceleration time (DT), E/e' ratio, tricuspid annular plane systolic excursion (TAPSE), and right ventricular-atrial gradient (RVAG). The LAV, MR, E/e', RAV, and RVAG significantly increased, whereas the LVEF and TAPSE significantly decreased in the left lateral position. All changes, however, were of negligible clinical significance. No significant changes were observed in CO, DT, and LVEDV. This study shows that the reduction of CSA severity from the supine to the left lateral position in patients with CHF is not due to an improvement in cardiac haemodynamics. Other, noncardiac factors are likely to represent the main cause. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Effect of dietary sodium and potassium intake on left ventricular diastolic function and mass in adults≤40 years (from the Strong Heart Study).

    PubMed

    Haring, Bernhard; Wang, Wenyu; Lee, Elisa T; Jhamnani, Sunny; Howard, Barbara V; Devereux, Richard B

    2015-05-01

    The aim of this study was to investigate whether intake of dietary sodium or potassium is related to changes in left ventricular (LV) diastolic functioning and LV mass index in young subjects with normal or elevated blood pressure. We prospectively analyzed echocardiographic data in 1,065 young adults (18 to 39 years) enrolled in the Strong Heart Family Study who were free from cardiovascular disease at baseline: 501 (47%) participants were normotensive and 564 (53%) were prehypertensive or hypertensive. Dietary sodium and potassium intakes were ascertained using a block food frequency questionnaire at baseline. Cardiac geometry and functioning were assessed at baseline and 4 years later. Marginal models were used to assess the associations of average intakes of sodium and potassium with echocardiographic measures. Participants with prehypertension or hypertension were older, had higher body mass index, and reported higher intakes of sodium than normotensive subjects at baseline. In prospective analyses, potassium intake was found to be negatively related to mitral E velocity (p=0.029) in normotensive subjects, whereas sodium/potassium ratio was positively associated with atrial filling fraction (p=0.017). In prehypertensive or hypertensive participants, sodium consumption was positively associated with atrial filling fraction (p=0.034) and an increase in sodium/potassium ratio was related to higher LV mass index (p=0.046). In conclusion, an increase in dietary sodium/potassium ratio was related to an accentuation of atrial phase LV diastolic filling in normotensive young subjects, whereas in prehypertensive or hypertensive subjects it was associated with higher LV mass index. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Right Ventricular Structure and Function Are Associated With Incident Atrial Fibrillation: MESA-RV Study (Multi-Ethnic Study of Atherosclerosis-Right Ventricle).

    PubMed

    Chatterjee, Neal A; Shah, Ravi V; Murthy, Venkatesh L; Praestgaard, Amy; Shah, Sanjiv J; Ventetuolo, Corey E; Barr, R Graham; Kronmal, Richard; Lima, Joao A C; Bluemke, David A; Jerosch-Herold, Michael; Alonso, Alvaro; Kawut, Steven M

    2017-01-01

    Right ventricular (RV) morphology has been associated with drivers of atrial fibrillation (AF) risk, including left ventricular and pulmonary pathology, systemic inflammation, and neurohormonal activation. The aim of this study was to investigate the association between RV morphology and risk of incident AF. We interpreted cardiac magnetic resonance imaging in 4204 participants free of clinical cardiovascular disease in the MESA (Multi-Ethnic Study of Atherosclerosis). Incident AF was determined using hospital discharge records, study electrocardiograms, and Medicare claims data. The study sample (n=3819) was 61±10 years old and 47% male with 47.2% current/former smokers. After adjustment for demographics and clinical factors, including incident heart failure, higher RV ejection fraction (hazard ratio, 1.16 per SD; 95% confidence interval, 1.03-1.32; P=0.02) and greater RV mass (hazard ratio, 1.25 per SD; 95% confidence interval, 1.08-1.44; P=0.002) were significantly associated with incident AF. After additional adjustment for the respective left ventricular parameter, higher RV ejection fraction remained significantly associated with incident AF (hazard ratio, 1.15 per SD; 95% confidence interval, 1.01-1.32; P=0.04), whereas the association was attenuated for RV mass (hazard ratio, 1.16 per SD; 95% confidence interval, 0.99-1.35; P=0.07). In a subset of patients with available spirometry (n=2540), higher RV ejection fraction and mass remained significantly associated with incident AF after additional adjustment for lung function (P=0.02 for both). Higher RV ejection fraction and greater RV mass were associated with an increased risk of AF in a multiethnic population free of clinical cardiovascular disease at baseline. © 2017 American Heart Association, Inc.

  13. Cardiac Structure and Function in Cushing's Syndrome: A Cardiac Magnetic Resonance Imaging Study

    PubMed Central

    Roux, Charles; Salenave, Sylvie; Kachenoura, Nadjia; Raissouni, Zainab; Macron, Laurent; Guignat, Laurence; Jublanc, Christel; Azarine, Arshid; Brailly, Sylvie; Young, Jacques; Mousseaux, Elie; Chanson, Philippe

    2014-01-01

    Background: Patients with Cushing's syndrome have left ventricular (LV) hypertrophy and dysfunction on echocardiography, but echo-based measurements may have limited accuracy in obese patients. No data are available on right ventricular (RV) and left atrial (LA) size and function in these patients. Objectives: The objective of the study was to evaluate LV, RV, and LA structure and function in patients with Cushing's syndrome by means of cardiac magnetic resonance, currently the reference modality in assessment of cardiac geometry and function. Methods: Eighteen patients with active Cushing's syndrome and 18 volunteers matched for age, sex, and body mass index were studied by cardiac magnetic resonance. The imaging was repeated in the patients 6 months (range 2–12 mo) after the treatment of hypercortisolism. Results: Compared with controls, patients with Cushing's syndrome had lower LV, RV, and LA ejection fractions (P < .001 for all) and increased end-diastolic LV segmental thickness (P < .001). Treatment of hypercortisolism was associated with an improvement in ventricular and atrial systolic performance, as reflected by a 15% increase in the LV ejection fraction (P = .029), a 45% increase in the LA ejection fraction (P < .001), and an 11% increase in the RV ejection fraction (P = NS). After treatment, the LV mass index and end-diastolic LV mass to volume ratio decreased by 17% (P < .001) and 10% (P = .002), respectively. None of the patients had late gadolinium myocardial enhancement. Conclusion: Cushing's syndrome is associated with subclinical biventricular and LA systolic dysfunctions that are reversible after treatment. Despite skeletal muscle atrophy, Cushing's syndrome patients have an increased LV mass, reversible upon correction of hypercortisolism. PMID:25093618

  14. Left Atrial Volume Determinants in Patients with Non-Ischemic Dilated Cardiomyopathy

    PubMed Central

    Mancuso, Frederico José Neves; Moisés, Valdir Ambrósio; Almeida, Dirceu Rodrigues; Poyares, Dalva; Storti, Luciana Julio; Oliveira, Wércules Antonio; Brito, Flavio Souza; de Paola, Angelo Amato Vincenzo; Carvalho, Antonio Carlos Camargo; Campos, Orlando

    2015-01-01

    Background Left atrial volume (LAV) is a predictor of prognosis in patients with heart failure. Objective We aimed to evaluate the determinants of LAV in patients with dilated cardiomyopathy (DCM). Methods Ninety patients with DCM and left ventricular (LV) ejection fraction ≤ 0.50 were included. LAV was measured with real-time three-dimensional echocardiography (eco3D). The variables evaluated were heart rate, systolic blood pressure, LV end-diastolic volume and end-systolic volume and ejection fraction (eco3D), mitral inflow E wave, tissue Doppler e´ wave, E/e´ ratio, intraventricular dyssynchrony, 3D dyssynchrony index and mitral regurgitation vena contracta. Pearson´s coefficient was used to identify the correlation of the LAV with the assessed variables. A multiple linear regression model was developed that included LAV as the dependent variable and the variables correlated with it as the predictive variables. Results Mean age was 52 ± 11 years-old, LV ejection fraction: 31.5 ± 8.0% (16-50%) and LAV: 39.2±15.7 ml/m2. The variables that correlated with the LAV were LV end-diastolic volume (r = 0.38; p < 0.01), LV end-systolic volume (r = 0.43; p < 0.001), LV ejection fraction (r = -0.36; p < 0.01), E wave (r = 0.50; p < 0.01), E/e´ ratio (r = 0.51; p < 0.01) and mitral regurgitation (r = 0.53; p < 0.01). A multivariate analysis identified the E/e´ ratio (p = 0.02) and mitral regurgitation (p = 0.02) as the only independent variables associated with LAV increase. Conclusion The LAV is independently determined by LV filling pressures (E/e´ ratio) and mitral regurgitation in DCM. PMID:25993483

  15. Left Atrial Volume Determinants in Patients with Non-Ischemic Dilated Cardiomyopathy.

    PubMed

    Mancuso, Frederico José Neves; Moisés, Valdir Ambrósio; Almeida, Dirceu Rodrigues; Poyares, Dalva; Storti, Luciana Julio; Oliveira, Wércules Antonio; Brito, Flavio Souza; Paola, Angelo Amato Vincenzo de; Carvalho, Antonio Carlos Camargo; Campos, Orlando

    2015-07-01

    Left atrial volume (LAV) is a predictor of prognosis in patients with heart failure. We aimed to evaluate the determinants of LAV in patients with dilated cardiomyopathy (DCM). Ninety patients with DCM and left ventricular (LV) ejection fraction ≤ 0.50 were included. LAV was measured with real-time three-dimensional echocardiography (eco3D). The variables evaluated were heart rate, systolic blood pressure, LV end-diastolic volume and end-systolic volume and ejection fraction (eco3D), mitral inflow E wave, tissue Doppler e' wave, E/e' ratio, intraventricular dyssynchrony, 3D dyssynchrony index and mitral regurgitation vena contracta. Pearson's coefficient was used to identify the correlation of the LAV with the assessed variables. A multiple linear regression model was developed that included LAV as the dependent variable and the variables correlated with it as the predictive variables. Mean age was 52 ± 11 years-old, LV ejection fraction: 31.5 ± 8.0% (16-50%) and LAV: 39.2±15.7 ml/m2. The variables that correlated with the LAV were LV end-diastolic volume (r = 0.38; p < 0.01), LV end-systolic volume (r = 0.43; p < 0.001), LV ejection fraction (r = -0.36; p < 0.01), E wave (r = 0.50; p < 0.01), E/e' ratio (r = 0.51; p < 0.01) and mitral regurgitation (r = 0.53; p < 0.01). A multivariate analysis identified the E/e' ratio (p = 0.02) and mitral regurgitation (p = 0.02) as the only independent variables associated with LAV increase. The LAV is independently determined by LV filling pressures (E/e' ratio) and mitral regurgitation in DCM.

  16. Heart Failure with Preserved Ejection Fraction - Concept, Pathophysiology, Diagnosis and Challenges for Treatment.

    PubMed

    Miljkovik, Lidija Veterovska; Spiroska, Vera

    2015-09-15

    Heart failure (HF) with preserved left ventricular (LV) ejection fraction (HFpEF) occurs in 40 to 60% of the patients with HF, with a prognosis which is similar to HF with reduced ejection fraction (HFrEF). HFpEF pathophysiology is different from that of HFrEF, and has been characterized with diastolic dysfunction. Diastolic dysfunction has been defined with elevated left ventricular stiffness, prolonged iso-volumetric LV relaxation, slow LV filing and elevated LV end-diastolic pressure. Arterial hypertension occurs in majority cases with HFpEF worldwide. Patients are mostly older and obese. Diabetes mellitus and atrial fibrillation appear proportionally in a high frequency of patients with HFpEF. The HFpEF diagnosis is based on existence of symptoms and signs of heart failure, normal or approximately normal ejection and diagnosing of LV diastolic dysfunction by means of heart catheterization or Doppler echocardiography and/or elevated concentration of plasma natriuretic peptide. The present recommendations for HFpEF treatment include blood pressure control, heart chamber frequency control when atrial fibrillation exists, in some situations even coronary revascularization and an attempt for sinus rhythm reestablishment. Up to now, it is considered that no medication or a group of medications improve the survival of HFpEF patients. Due to these causes and the bad prognosis of the disorder, rigorous control is recommended of the previously mentioned precipitating factors for this disorder. This paper presents a universal review of the most important parameters which determine this disorder.

  17. Correlation of transforming growth factor-β1 and tumour necrosis factor levels with left ventricular function in Chagas disease

    PubMed Central

    Curvo, Eduardo OV; Ferreira, Roberto R; Madeira, Fabiana S; Alves, Gabriel F; Chambela, Mayara C; Mendes, Veronica G; Sangenis, Luiz Henrique C; Waghabi, Mariana C; Saraiva, Roberto M

    2018-01-01

    BACKGROUND Transforming growth factor β1 (TGF-β1) and tumour necrosis factor (TNF) have been implicated in Chagas disease pathophysiology and may correlate with left ventricular (LV) function. OBJECTIVES We determined whether TGF-β1 and TNF serum levels correlate with LV systolic and diastolic functions and brain natriuretic peptide (BNP) serum levels in chronic Chagas disease. METHODS This cross-sectional study included 152 patients with Chagas disease (43% men; 57 ± 12 years old), classified as 53 patients with indeterminate form and 99 patients with cardiac form (stage A: 24, stage B: 25, stage C: 44, stage D: 6). TGF-β1, TNF, and BNP were determined by enzyme-linked immunosorbent assay ELISA. Echocardiogram was used to determine left atrial and LV diameters, as well as LV ejection fraction and diastolic function. FINDINGS TGF-b1 serum levels were lower in stages B, C, and D, while TNF serum levels were higher in stages C and D of the cardiac form. TGF-β1 presented a weak correlation with LV diastolic function and LV ejection fraction. TNF presented a weak correlation with left atrial and LV diameters and LV ejection fraction. CONCLUSIONS TNF is increased, while TGF-β1 is decreased in the cardiac form of chronic Chagas disease. TNF and TGF-β1 serum levels present a weak correlation with LV systolic and diastolic function in Chagas disease patients. PMID:29513876

  18. Pheochromocytoma-Induced Atrial Tachycardia Leading to Cardiogenic Shock and Cardiac Arrest: Resolution with Atrioventricular Node Ablation and Pacemaker Placement

    PubMed Central

    Bajaj, Mandeep; Cunningham, Glenn R.

    2014-01-01

    Pheochromocytoma should be considered in young patients who have acute cardiac decompensation, even if they have no history of hypertension. Atrioventricular node ablation and pacemaker placement should be considered for stabilizing pheochromocytoma patients with cardiogenic shock due to atrial tachyarrhythmias. A 38-year-old black woman presented with cardiogenic shock (left ventricular ejection fraction, <0.15) that did not respond to the placement of an intra-aortic balloon pump. A TandemHeart® Percutaneous Ventricular Assist Device was inserted emergently. After atrioventricular node ablation and placement of a temporary pacemaker, the TandemHeart was removed. Computed tomography of the abdomen revealed a pheochromocytoma. After placement of a permanent pacemaker, the patient underwent a right adrenalectomy. This is, to our knowledge, the first reported case of pheochromocytoma-induced atrial tachyarrhythmia that led to cardiogenic shock and cardiac arrest unresolved by the placement of 2 different ventricular assist devices, but that was completely reversed by radiofrequency ablation of the atrioventricular node and the placement of a temporary pacemaker. We present the patient's clinical, laboratory, and imaging findings, and we review the relevant literature. PMID:25593537

  19. Flow-gradient patterns in severe aortic stenosis with preserved ejection fraction: clinical characteristics and predictors of survival.

    PubMed

    Eleid, Mackram F; Sorajja, Paul; Michelena, Hector I; Malouf, Joseph F; Scott, Christopher G; Pellikka, Patricia A

    2013-10-15

    Among patients with severe aortic stenosis (AS) and preserved ejection fraction, those with low gradient (LG) and reduced stroke volume may have an adverse prognosis. We investigated the prognostic impact of stroke volume using the recently proposed flow-gradient classification. We examined 1704 consecutive patients with severe AS (aortic valve area <1.0 cm(2)) and preserved ejection fraction (≥50%) using 2-dimensional and Doppler echocardiography. Patients were stratified by stroke volume index (<35 mL/m(2) [low flow, LF] versus ≥35 mL/m(2) [normal flow, NF]) and aortic gradient (<40 mm Hg [LG] versus ≥40 mm Hg [high gradient, HG]) into 4 groups: NF/HG, NF/LG, LF/HG, and LF/LG. NF/LG (n=352, 21%), was associated with favorable survival with medical management (2-year estimate, 82% versus 67% in NF/HG; P<0.0001). LF/LG severe AS (n=53, 3%) was characterized by lower ejection fraction, more prevalent atrial fibrillation and heart failure, reduced arterial compliance, and reduced survival (2-year estimate, 60% versus 82% in NF/HG; P<0.001). In multivariable analysis, the LF/LG pattern was the strongest predictor of mortality (hazard ratio, 3.26; 95% confidence interval, 1.71-6.22; P<0.001 versus NF/LG). Aortic valve replacement was associated with a 69% mortality reduction (hazard ratio, 0.31; 95% confidence interval, 0.25-0.39; P<0.0001) in LF/LG and NF/HG, with no survival benefit associated with aortic valve replacement in NF/LG and LF/HG. NF/LG severe AS with preserved ejection fraction exhibits favorable survival with medical management, and the impact of aortic valve replacement on survival was neutral. LF/LG severe AS is characterized by a high prevalence of atrial fibrillation, heart failure, and reduced survival, and aortic valve replacement was associated with improved survival. These findings have implications for the evaluation and subsequent management of AS severity.

  20. Interventional endocardial motion estimation from electroanatomical mapping data: application to scar characterization.

    PubMed

    Porras, Antonio R; Piella, Gemma; Berruezo, Antonio; Hoogendoorn, Corne; Andreu, David; Fernandez-Armenta, Juan; Sitges, Marta; Frangi, Alejandro F

    2013-05-01

    Scar presence and its characteristics play a fundamental role in several cardiac pathologies. To accurately define the extent and location of the scar is essential for a successful ventricular tachycardia ablation procedure. Nowadays, a set of widely accepted electrical voltage thresholds applied to local electrograms recorded are used intraoperatively to locate the scar. Information about cardiac mechanics could be considered to characterize tissues with different viability properties. We propose a novel method to estimate endocardial motion from data obtained with an electroanatomical mapping system together with the endocardial geometry segmented from preoperative 3-D magnetic resonance images, using a statistical atlas constructed with bilinear models. The method was validated using synthetic data generated from ultrasound images of nine volunteers and was then applied to seven ventricular tachycardia patients. Maximum bipolar voltages, commonly used to intraoperatively locate scar tissue, were compared to endocardial wall displacement and strain for all the patients. The results show that the proposed method allows endocardial motion and strain estimation and that areas with low-voltage electrograms also present low strain values.

  1. Magnetic resonance imaging-compatible circular mapping catheter: an in vivo feasibility and safety study.

    PubMed

    Elbes, Delphine; Magat, Julie; Govari, Assaf; Ephrath, Yaron; Vieillot, Delphine; Beeckler, Christopher; Weerasooriya, Rukshen; Jais, Pierre; Quesson, Bruno

    2017-03-01

    Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  2. Relationship between left atrium catheter contact force and pacing threshold.

    PubMed

    Barrio-López, Teresa; Ortiz, Mercedes; Castellanos, Eduardo; Lázaro, Carla; Salas, Jefferson; Madero, Sergio; Almendral, Jesús

    2017-08-01

    The purpose of this study is to analyze the relationship between contact force (CF) and pacing threshold in left atrium (LA). Six to ten LA sites were studied in 28 consecutive patients with atrial fibrillation undergoing pulmonary vein isolation. Median CF, bipolar and unipolar electrogram voltage, impedance, and bipolar and unipolar thresholds for consistent constant capture and for consistent intermittent capture were measured at each site. Pacing threshold measurements were performed at 188 LA sites. Both unipolar and bipolar pacing thresholds correlated significantly with median CF; however, unipolar pacing threshold correlated better (unipolar: Pearson R -0.45; p < 0.001; Spearman Rho -0.62; p < 0.001, bipolar: Pearson R -0.39; p < 0.001; Spearman Rho -0.52; p < 0.001). Consistent constant capture threshold had better correlation with median CF than consistent intermittent capture threshold for both unipolar and bipolar pacing (Pearson R -0.45; p < 0.001 and Spearman Rho -0.62; p < 0.001 vs. Pearson R -0.35; p < 0.001; Spearman Rho -0.52; p < 0.001). The best pacing threshold cutoff point to detect a good CF (>10 g) was 3.25 mA for unipolar pacing with 69% specificity and 73% sensitivity. Both increased to 80% specificity and 74% sensitivity for sites with normal bipolar voltage and a pacing threshold cutoff value of 2.85 mA. Pacing thresholds correlate with CF in human not previously ablated LA. Since the combination of a normal bipolar voltage and a unipolar pacing threshold <2.85 mA provide reasonable parameters of validity, pacing threshold could be of interest as a surrogate for CF in LA.

  3. Influence of Intramyocardial Adipose Tissue on the Accuracy of Endocardial Contact Mapping of the Chronic Myocardial Infarction Substrate.

    PubMed

    Samanta, Rahul; Kumar, Saurabh; Chik, William; Qian, Pierre; Barry, Michael A; Al Raisi, Sara; Bhaskaran, Abhishek; Farraha, Melad; Nadri, Fazlur; Kizana, Eddy; Thiagalingam, Aravinda; Kovoor, Pramesh; Pouliopoulos, Jim

    2017-10-01

    Recent studies have demonstrated that intramyocardial adipose tissue (IMAT) may contribute to ventricular electrophysiological remodeling in patients with chronic myocardial infarction. Using an ovine model of myocardial infarction, we aimed to determine the influence of IMAT on scar tissue identification during endocardial contact mapping and optimal voltage-based mapping criteria for defining IMAT dense regions. In 7 sheep, left ventricular endocardial and transmural mapping was performed 84 weeks (15-111 weeks) post-myocardial infarction. Spearman rank correlation coefficient was used to assess the relationship between endocardial contact electrogram amplitude and histological composition of myocardium. Receiver operator characteristic curves were used to derive optimal electrogram thresholds for IMAT delineation during endocardial mapping and to describe the use of endocardial mapping for delineation of IMAT dense regions within scar. Endocardial electrogram amplitude correlated significantly with IMAT (unipolar r =-0.48±0.12, P <0.001; bipolar r =-0.45±0.22, P =0.04) but not collagen (unipolar r =-0.36±0.24, P =0.13; bipolar r =-0.43±0.31, P =0.16). IMAT dense regions of myocardium reliably identified using endocardial mapping with thresholds of <3.7 and <0.6 mV, respectively, for unipolar, bipolar, and combined modalities (single modality area under the curve=0.80, P <0.001; combined modality area under the curve=0.84, P <0.001). Unipolar mapping using optimal thresholding remained significantly reliable (area under the curve=0.76, P <0.001) during mapping of IMAT, confined to putative scar border zones (bipolar amplitude, 0.5-1.5 mV). These novel findings enhance our understanding of the confounding influence of IMAT on endocardial scar mapping. Combined bipolar and unipolar voltage mapping using optimal thresholds may be useful for delineating IMAT dense regions of myocardium, in postinfarct cardiomyopathy. © 2017 American Heart Association, Inc.

  4. Discrete potentials guided radiofrequency ablation for idiopathic outflow tract ventricular arrhythmias.

    PubMed

    Liu, Enzhao; Xu, Gang; Liu, Tong; Ye, Lan; Zhang, Qitong; Zhao, Yanshu; Li, Guangping

    2015-03-01

    Discrete potentials (DPs) have been recorded and targeted as the site of ablation of the outflow tract arrhythmias. The aim of the present study was to investigate the significance of DPs with respect to mapping and ablation for idiopathic outflow tract premature ventricular contractions (PVCs) or ventricular tachycardias (VTs). Seventeen consecutive patients with idiopathic right or left ventricular outflow tract PVCs/VTs who underwent radiofrequency catheter ablation were included. Intracardiac electrograms during the mapping and ablation were analysed. During sinus rhythm, sharp high-frequency DPs that displayed double or multiple components were recorded following or buried in the local ventricular electrograms in all of the 17 patients, peak amplitude 0.51 ± 0.21 mV. The same potential was recorded prior to the local ventricular potential of the PVCs/VTs. Spontaneous reversal of the relationship of the DPs to the local ventricular electrogram during the arrhythmias was noted. The DPs were related to a region of low voltage showed by intracardiac high-density contact mapping. At the sites with DPs, lower unipolar and bipolar ventricular voltage of sinus beats were noted compared with the adjacent regions without DPs (unipolar: 6.1 ± 1.8 vs. 8.3 ± 2.3 mV, P < 0.05; bipolar: 0.62 ± 0.45 vs. 1.03 ± 0.60 mV, P < 0.05). The targeted DPs were still present in 12 patients after successful elimination of the ectopies. Discrete potentials were not present in seven controls. Discrete potentials and related low-voltage regions were common in idiopathic outflow tract ventricular arrhythmias. Discrete potential- and substrate-guided ablation strategy will help to reduce the recurrence of idiopathic outflow tract arrhythmias. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  5. Temporary epicardial cardiac resynchronisation versus conventional right ventricular pacing after cardiac surgery: study protocol for a randomised control trial.

    PubMed

    Russell, Stuart J; Tan, Christine; O'Keefe, Peter; Ashraf, Saeed; Zaidi, Afzal; Fraser, Alan G; Yousef, Zaheer R

    2012-02-20

    Heart failure patients with stable angina, acute coronary syndromes and valvular heart disease may benefit from revascularisation and/or valve surgery. However, the mortality rate is increased- 5-30%. Biventricular pacing using temporary epicardial wires after surgery is a potential mechanism to improve cardiac function and clinical endpoints. A multi-centred, prospective, randomised, single-blinded, intervention-control trial of temporary biventricular pacing versus standard pacing. Patients with ischaemic cardiomyopathy, valvular heart disease or both, an ejection fraction ≤ 35% and a conventional indication for cardiac surgery will be recruited from 2 cardiac centres. Baseline investigations will include: an electrocardiogram to confirm sinus rhythm and measure QRS duration; echocardiogram to evaluate left ventricular function and markers of mechanical dyssynchrony; dobutamine echocardiogram for viability and blood tests for renal function and biomarkers of myocardial injury- troponin T and brain naturetic peptide. Blood tests will be repeated at 18, 48 and 72 hours. The principal exclusions will be subjects with permanent atrial arrhythmias, permanent pacemakers, infective endocarditis or end-stage renal disease.After surgery, temporary pacing wires will be attached to the postero-lateral wall of the left ventricle, the right atrium and right ventricle and connected to a triple chamber temporary pacemaker. Subjects will be randomised to receive either temporary biventricular pacing or standard pacing (atrial inhibited pacing or atrial-synchronous right ventricular pacing) for 48 hours.The primary endpoint will be the duration of level 3 care. In brief, this is the requirement for invasive ventilation, multi-organ support or more than one inotrope/vasoconstrictor. Haemodynamic studies will be performed at baseline, 6, 18 and 24 hours after surgery using a pulmonary arterial catheter. Measurements will be taken in the following pacing modes: atrial inhibited; right ventricular only; atrial synchronous-right ventricular; atrial synchronous-left ventricular and biventricular pacing. Optimisation of the atrioventricular and interventricular delay will be performed in the biventricular pacing group at 18 hours. The effect of biventricular pacing on myocardial injury, post operative arrhythmias and renal function will also be quantified. ClinicalTrials.gov: NCT01027299.

  6. Quantification of atrial dynamics using cardiovascular magnetic resonance: inter-study reproducibility.

    PubMed

    Kowallick, Johannes T; Morton, Geraint; Lamata, Pablo; Jogiya, Roy; Kutty, Shelby; Hasenfuß, Gerd; Lotz, Joachim; Nagel, Eike; Chiribiri, Amedeo; Schuster, Andreas

    2015-05-17

    Cardiovascular magnetic resonance (CMR) offers quantification of phasic atrial functions based on volumetric assessment and more recently, on CMR feature tracking (CMR-FT) quantitative strain and strain rate (SR) deformation imaging. Inter-study reproducibility is a key requirement for longitudinal studies but has not been defined for CMR-based quantification of left atrial (LA) and right atrial (RA) dynamics. Long-axis 2- and 4-chamber cine images were acquired at 9:00 (Exam A), 9:30 (Exam B) and 14:00 (Exam C) in 16 healthy volunteers. LA and RA reservoir, conduit and contractile booster pump functions were quantified by volumetric indexes as derived from fractional volume changes and by strain and SR as derived from CMR-FT. Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to address possible diurnal variation of atrial function. Inter-study reproducibility was within acceptable limits for all LA and RA volumetric, strain and SR parameters. Inter-study reproducibility was better for volumetric indexes and strain than for SR parameters and better for LA than for RA dynamics. For the LA, reservoir function showed the best reproducibility (intraclass correlation coefficient (ICC) 0.94-0.97, coefficient of variation (CoV) 4.5-8.2%), followed by conduit (ICC 0.78-0.97, CoV 8.2-18.5%) and booster pump function (ICC 0.71-0.95, CoV 18.3-22.7). Similarly, for the RA, reproducibility was best for reservoir function (ICC 0.76-0.96, CoV 7.5-24.0%) followed by conduit (ICC 0.67-0.91, CoV 13.9-35.9) and booster pump function (ICC 0.73-0.90, CoV 19.4-32.3). Atrial dynamics were not measurably affected by diurnal variation between morning and afternoon scans. Inter-study reproducibility for CMR-based derivation of LA and RA functions is acceptable using either volumetric, strain or SR parameters with LA function showing higher reproducibility than RA function assessment. Amongst the different functional components, reservoir function is most reproducibly assessed by either technique followed by conduit and booster pump function, which needs to be considered in future longitudinal research studies.

  7. Association of left ventricular late gadolinium enhancement with left atrial low voltage areas in patients with atrial fibrillation.

    PubMed

    Stegmann, Clara; Jahnke, Cosima; Paetsch, Ingo; Hilbert, Sebastian; Arya, Arash; Bollmann, Andreas; Hindricks, Gerhard; Sommer, Philipp

    2018-02-06

    Presence of late gadolinium enhancement (LGE) is related to adverse cardiovascular outcome. Many patients suffering from atrial fibrillation (AF) undergo cardiovascular magnetic resonance (CMR) imaging prior to ablation. Since quantification of atrial fibrosis still lacks reproducibility, we sought to investigate risk factors for the presence of left ventricular (LV)-LGE and a possible correlation between ventricular fibrosis as defined by positive LGE and pathological atrial voltage maps evaluated by 3D mapping systems. Between May 2015 and January 2017, 241 patients with AF (73% persistent AF, 71% male, mean age 62.8 ± 10.1 years, Redo procedure in 24%, AF history 4.5 ± 5.2 years) underwent CMR including LV LGE prior to pulmonary vein (PV) isolation at Heart Center Leipzig. Depending on CMR results, two groups were separated: 'LV-LGE negative' (Group A, n = 197, 82%) and 'LV-LGE positive' (Group B, n = 44, 18%). To identify low voltage areas (LVA), a 3D electro-anatomic map was created during PV isolation. Multivariate analysis revealed male gender [odds ratio (OR) 7.6, 95% confidence interval (95% CI) 2.4-23.9, P = 0.001] and an increased CHA2DS2VASc Score (OR 1.6, 95% CI 1.2-2.2, P = 0.004) as significantly associated with LV-LGE. Impaired left ventricular ejection fraction, LV dilatation, larger LA size and, enlarged septum diameter occurred significantly more often in the 'LGE positive' group. Low voltage areas were detected in 83 patients overall (34%): Group A: n = 64/197 (33%), Group B: n = 19/44 (43%) (P = 0.177). Male gender and high CHA2DS2VASc Score are significantly associated with presence of LV-LGE, but LV-LGE is not associated with left atrial LVA. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.

  8. Left atrial volume and function in dogs with naturally occurring myxomatous mitral valve disease.

    PubMed

    Höllmer, M; Willesen, J L; Tolver, A; Koch, J

    2017-02-01

    Myxomatous mitral valve disease (MMVD) induces progressive left atrial (LA) enlargement. The LA modulates left ventricular filling and performance through its reservoir, conduit, and contractile function. Assessment of LA size and function may provide valuable information on the level of cardiac compensation. Left atrial function in dogs with naturally occurring MMVD remains largely unexplored. The objective of this study was to evaluate LA volume and function in dogs with naturally occurring MMVD. This prospective study included 205 client-owned dogs of different breeds, 114 healthy dogs, and 91 dogs with MMVD of different disease severities. Using two-dimensional echocardiography, the biplane area-length method was applied to assess LA volume and calculate volumetric indices of LA reservoir, conduit, and contractile function. Left atrial volume and LA stroke volume increased, whereas LA reservoir and contractile function decreased with increasing disease severity. A maximal LA volume <2.25mL/kg was the optimal cut off identified for excluding congestive heart failure in dogs with chronic MMVD with a sensitivity of 96% and a specificity of 100%. An active LA emptying fraction <24% and/or a LA expansion index <126% were suggestive of congestive heart failure in dogs with chronic MMVD with a sensitivity of 77% and a specificity of 89% and a sensitivity of 82% and a specificity of 82%, respectively. Dogs with MMVD appear to have larger LA volumes with poorer LA function. Deteriorating LA function, characterized by a decreasing reservoir and active contractile function, was evident in dogs with MMVD with increasing disease severity. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Relating regional characteristics of left atrial shape to presence of scar in patients with atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Sanatkhani, Soroosh; Oladosu, Michael; Chera, Karandeep; Nedios, Sotirios; Menon, Prahlad G.

    2018-03-01

    Pulmonary vein isolation (PVI) is an established procedure for atrial fibrillation (AF) patients. Pre-procedural screening is necessary prior to PVI in order to reduce the likelihood of AF recurrence and improve overall success rate of the procedure. However, current reliable methods to determine AF triggers are invasive. In this paper, we present an approach to relate the regional characteristics of left atrial (LA) shape to existence of low-voltage areas (LVA) which indicate the presence of scar in invasive exams. A cohort of 29 AF patient-specific clinical images were each segmented into 3D surface bodies representing the LA. Iterative closest point based similarity transformation was used to find the best fit sphere to each patient-specific LA and the mean deviation of LA wall to this sphere of best fit was determined using a signed point-to-surface regional distance metric. Regional departure from the best-fit sphere was reduced into a metric of global LA sphericity. Next, the LA was divided into six regions to perform an analysis of regional sphericity. Regional sphericity analysis revealed that sphericity of the inferior-posterior LA region was found to be related to several clinical variables, including a direct correlation with body mass index (BMI) and an inverse correlation with left ventricular ejection fraction (EF), which presents a diseased heart that has been asymmetrically inflated. Our observations therefore demonstrate promise in being leveraged as a non-invasive patient selection tool to increase the success rate of PVI procedures.

  10. A clinical comparison between a new dual-chamber pacing mode-AAIsafeR and DDD mode.

    PubMed

    Xue-Jun, Ren; Zhihong, Han; Ye, Wang; Huifeng, Du; Jinrong, Zhang; Fang, Chen; Jihong, Guo

    2010-02-01

    The aim of this study was to compare the cross-follow-up results in DDD or AAISafeR mode and to describe the safety and effectiveness of this pacing mode. The Symphony 2450/2550 cardiac pacemakers were implanted in 30 patients with sick sinus syndrome between February 2006 and September 2006. They were randomized to the DDD mode or AAISafeR mode for 3 months and then crossed over to the alternate pacing modality for an additional 3 months. No AAISafeR-related adverse event was observed. All documented episodes of paroxysmal atrial ventricular block caused the immediate switch of the pacing mode from AAI to DDD. The cumulative percent ventricular pacing was significantly reduced in the AAISafeR mode compared with the DDD mode (0.9% [0%-3%] versus 51.3% [2%-91%] P = 0.001; 2.94% [0%-18%] versus 41.18% [0%-65%] P = 0.0001). After 3 months in DDD mode, left atrial diameter, left ventricular enddiastolic diameter, and left ventricular end-systolic diameter increased significantly and left ventricular ejection fraction decreased. However, no obvious changes appeared in 3 months of AAISafeR mode. Switches to DDD occurred during follow-up in 21 patients due to different-degree atrial ventricular block. The AAISafeR mode substantially reduces the amount of unnecessary right ventricular pacing in the bradycardia population and effectively prevents the deleterious effects on cardiac performance. An international randomized study will further ascertain the efficacy of this new pacing mode specifically in the prevention of heart failure hospitalization and atrial fibrillation.

  11. A novel approach to restore atrial function after the maze procedure in patients with an enlarged left atrium.

    PubMed

    Marui, Akira; Tambara, Keiichi; Tadamura, Eiji; Saji, Yoshiaki; Sasahashi, Nozomu; Ikeda, Tadashi; Nishina, Takeshi; Komeda, Masashi

    2007-08-01

    Left atrial (LA) volume reduction surgery concomitant with the maze procedure has been reported to facilitate sinus rhythm recovery even in patients with refractory atrial fibrillation (AF) with an enlarged LA. However, it is unknown whether the procedures can also restore effective atrial function of the enlarged LA with over-stretched myocardium. The maze procedures in association with mitral valve surgery were performed to 57 AF patients with an enlarged LA (LA diameter >or=60mm). Among them, 32 patients had concomitant LA volume reduction surgery (VR group). Another 25 patients did not have the volume reduction (control group). Three months postoperatively LA end-diastolic volume (LAEDV, ml) assessed by magnetic resonance (MR) imaging was larger in the VR group than that in the control group (291+/-117 vs 223+/-81 ml, p<0.05). Postoperatively, sinus rhythm recovery rate was better (84 vs 68%, p<0.05) and LAEDV was drastically smaller (118+/-48 vs 203+/-76 ml, p<0.001) in the VR group than those in the control group. Among the patients with sinus rhythm recovery in both groups, LA contraction ejection fraction (%) improved in the VR group but not in the control group (22.3+/-7.8 vs 10.3+/-4.7%, p<0.001). The LA volume reduction surgery concomitant with the maze procedure restored contraction of the enlarged LA; however, the maze procedure alone did not restore LA contraction in spite of successful sinus rhythm recovery. LA volume reduction surgery may be desirable to the patients with refractory AF with over-stretched LA.

  12. Regular endurance training in adolescents impacts atrial and ventricular size and function.

    PubMed

    Rundqvist, Louise; Engvall, Jan; Faresjö, Maria; Carlsson, Emma; Blomstrand, Peter

    2017-06-01

    The aims of the study were to explore the effects of long-term endurance exercise on atrial and ventricular size and function in adolescents and to examine whether these changes are related to maximal oxygen uptake (VO2max). Twenty-seven long-term endurance-trained adolescents aged 13-19 years were individually matched by age and gender with 27 controls. All participants, 22 girls and 32 boys, underwent an echocardiographic examination at rest, including standard and colour tissue Doppler investigation. VO2max was assessed during treadmill exercise. All heart dimensions indexed for body size were larger in the physically active group compared with controls: left ventricular end-diastolic volume 60 vs. 50 mL/m2 (P <0.001), left atrial volume 27 vs. 19 mL/m2 (P < 0.001), and right ventricular (RV) and right atrial area 15 vs. 13 and 9 vs. 7 cm2/m2, respectively (P <0.001 for both). There were strong associations between the size of the cardiac chambers and VO2max. Further, we found improved systolic function in the active group compared with controls: left ventricular ejection fraction 61 vs. 59% (P= 0.036), tricuspid annular plane systolic excursion 12 vs. 10 mm/m2 (P= 0.008), and RV early peak systolic velocity s' 11 vs. 10 cm/s (P = 0.031). Cardiac remodelling to long-term endurance exercise in adolescents is manifested by an increase in atrial as well as ventricular dimensions. The physically active group also demonstrated functional remodelling with an increase in TAPSE and systolic RV wall velocity. These findings have practical implications when assessing cardiac enlargement and function in physically active youngsters. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  13. Relationship between connexin expression and gap-junction resistivity in human atrial myocardium.

    PubMed

    Dhillon, Paramdeep S; Chowdhury, Rasheda A; Patel, Pravina M; Jabr, Rita; Momin, Aziz U; Vecht, Joshua; Gray, Rosaire; Shipolini, Alex; Fry, Christopher H; Peters, Nicholas S

    2014-04-01

    The relative roles of the gap-junctional proteins connexin40 (Cx40) and connexin43 (Cx43) in determining human atrial myocardial resistivity is unknown. In addressing the hypothesis that changing relative expression of Cx40 and Cx43 underlies an increase in human atrial myocardial resistivity with age, this relationship was investigated by direct ex vivo measurement of gap-junctional resistivity and quantitative connexin immunoblotting and immunohistochemistry. Oil-gap impedance measurements were performed to determine resistivity of the intracellular pathway (Ri), which correlated with total Cx40 quantification by Western blotting (rs=0.64, P<0.01, n=20). Specific gap-junctional resistivity (Rj) correlated not only with Western immunoquantification of Cx40 (rs=0.63, P=0.01, n=20), but also more specifically, with the Cx40 fraction localized to the intercalated disks on immunohistochemical quantification (rs=0.66, P=0.02, n=12). Although Cx43 expression showed no correlation with resistivity values, the proportional expression of the 2 connexins, (Cx40/[Cx40+Cx43]) correlated with Ri and Rj (rs=0.58, P<0.01 for Ri and rs=0.51, P=0.02 for Rj). Advancing age was associated with a rise in Ri (rs=0.77, P<0.0001), Rj (rs=0.65, P<0.001, n=23), Cx40 quantity (rs=0.54, P=0.01, n=20), and Cx40 gap-junction protein per unit area of en face disk (rs=0.61, P=0.02, n=12). Cx40 is associated with human right atrial gap-junctional resistivity such that increased total, gap-junctional, and proportional Cx40 expression increases gap-junctional resistivity. Accordingly, advancing age is associated with an increase in Cx40 expression and a corresponding increase in gap-junctional resistivity. These findings are the first to demonstrate this relationship and a mechanistic explanation for changing atrial conduction and age-related arrhythmic tendency.

  14. Prognostic Factors in Severe Chagasic Heart Failure

    PubMed Central

    Costa, Sandra de Araújo; Rassi, Salvador; Freitas, Elis Marra da Madeira; Gutierrez, Natália da Silva; Boaventura, Fabiana Miranda; Sampaio, Larissa Pereira da Costa; Silva, João Bastista Masson

    2017-01-01

    Background Prognostic factors are extensively studied in heart failure; however, their role in severe Chagasic heart failure have not been established. Objectives To identify the association of clinical and laboratory factors with the prognosis of severe Chagasic heart failure, as well as the association of these factors with mortality and survival in a 7.5-year follow-up. Methods 60 patients with severe Chagasic heart failure were evaluated regarding the following variables: age, blood pressure, ejection fraction, serum sodium, creatinine, 6-minute walk test, non-sustained ventricular tachycardia, QRS width, indexed left atrial volume, and functional class. Results 53 (88.3%) patients died during follow-up, and 7 (11.7%) remained alive. Cumulative overall survival probability was approximately 11%. Non-sustained ventricular tachycardia (HR = 2.11; 95% CI: 1.04 - 4.31; p<0.05) and indexed left atrial volume ≥ 72 mL/m2 (HR = 3.51; 95% CI: 1.63 - 7.52; p<0.05) were the only variables that remained as independent predictors of mortality. Conclusions The presence of non-sustained ventricular tachycardia on Holter and indexed left atrial volume > 72 mL/m2 are independent predictors of mortality in severe Chagasic heart failure, with cumulative survival probability of only 11% in 7.5 years. PMID:28443956

  15. Vitamin D and new-onset atrial fibrillation: A meta-analysis of randomized controlled trials.

    PubMed

    Huang, Wei-Ling; Yang, Jun; Yang, Jian; Wang, Hui-Bo; Yang, Chao-Jun; Yang, Ying

    2017-11-14

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, which affects 1.5% to 2% of the general population. More than six million Europeans suffer from AF. To research vitamin D levels in the prevention of new-onset atrial fibrillation (AF), we conducted a systematic review of randomized controlled trials (RCTs). We focused on the vitamin D levels in the prevention of new-onset AF. The outcomes assessed were vitamin D levels, left ventricular ejection fraction (LVEF), and left atrium diameter. Six RCTs ultimately met the inclusion criteria in the meta-analysis. The outcomes of Vitamin D levels (MD = -4.27, 95% CI = -5.20 to-3.34, P = 0.30) in the new-onset AF showed no significant difference. The left atrium diameter (MD = 1.96, 95% CI = 1.48 to 2.60, P < 0.01) between new-onset AF and LVEF (MD = -0.92, 95% CI = -1.59 to -0.26, P < 0.01) showed significant difference. Our study shows that circulating vitamin D levels may not play a major role in the development of new-onset AF. Copyright © 2017 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  16. An Electromechanical Left Ventricular Wedge Model to Study the Effects of Deformation on Repolarization during Heart Failure

    PubMed Central

    Rocha, B. M.; Toledo, E. M.; Barra, L. P. S.; dos Santos, R. Weber

    2015-01-01

    Heart failure is a major and costly problem in public health, which, in certain cases, may lead to death. The failing heart undergo a series of electrical and structural changes that provide the underlying basis for disturbances like arrhythmias. Computer models of coupled electrical and mechanical activities of the heart can be used to advance our understanding of the complex feedback mechanisms involved. In this context, there is a lack of studies that consider heart failure remodeling using strongly coupled electromechanics. We present a strongly coupled electromechanical model to study the effects of deformation on a human left ventricle wedge considering normal and hypertrophic heart failure conditions. We demonstrate through a series of simulations that when a strongly coupled electromechanical model is used, deformation results in the thickening of the ventricular wall that in turn increases transmural dispersion of repolarization. These effects were analyzed in both normal and failing heart conditions. We also present transmural electrograms obtained from these simulations. Our results suggest that the waveform of electrograms, particularly the T-wave, is influenced by cardiac contraction on both normal and pathological conditions. PMID:26550570

  17. An automated, web-enabled and searchable database system for archiving electrogram and related data from implantable cardioverter defibrillators.

    PubMed

    Zong, W; Wang, P; Leung, B; Moody, G B; Mark, R G

    2002-01-01

    The advent of implantable cardioverter defibrillators (ICDs) has resulted in significant reductions in mortality in patients at high risk for sudden cardiac death. Extensive related basic research and clinical investigation continue. ICDs typically record intracardiac electrograms and inter-beat intervals along with device settings during episodes of device delivery of therapy. Researchers wishing to study these data further have until now been limited to viewing paper plots. In support of multi-center clinical studies of patients with ICDs, we have developed a web based searchable ICD data archiving system, which allows users to use a web browser to upload ICD data from diskettes to a server where the data are automatically processed and archived. Users can view and download the archived ICD data directly via the web. The entire system is built from open source software. At present more than 500 patient ICD data sets have been uploaded to and archived in the system. This project will be of value not only to those who wish to conduct research using ICD data, but also to clinicians who need to archive and review ICD data collected from their patients.

  18. Prognostication of valvular aortic stenosis using tissue Doppler echocardiography: underappreciated importance of late diastolic mitral annular velocity.

    PubMed

    Poh, Kian-Keong; Chan, Mark Yan-Yee; Yang, Hong; Yong, Quek-Wei; Chan, Yiong-Huak; Ling, Lieng H

    2008-05-01

    Intact left atrial booster pump function helps maintain cardiac compensation in patients with aortic valve stenosis (AS). Because late diastolic mitral annular (A') velocity reflects left atrial systolic function, we hypothesized that A' velocity correlates with plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) level and clinical outcome in AS. We prospectively enrolled 53 consecutive patients (median age 74 years) with variable degrees of AS, in sinus rhythm, and left ventricular ejection fraction greater than 50%. Indices of valvular stenosis, left ventricular diastolic dysfunction, and mitral annular motion were correlated with plasma NT-proBNP and a composite clinical end point comprising cardiac death and symptom-driven aortic valve replacement. Tissue Doppler echocardiographic parameters, including early diastolic (E') velocity and A' velocity and ratio of early diastolic transmitral (E) to E' velocity (E/E') at the annular septum correlated better with NT-proBNP levels than body surface area-indexed aortic valve area. Eighteen patients had the composite end point, which was univariately predicted by body surface area-indexed aortic valve area, NT-proBNP, and all tissue Doppler echocardiographic indices. This outcome was most strongly predicted by the combination of septal A' velocity and E/E' ratio in bivariate Cox modeling. Septal annular A' velocity less than 9.6 cm/s was associated with significantly reduced event-free survival (Kaplan Meier log rank = 27.3, P < .0001) and predicted the end point with a sensitivity, specificity, and accuracy of 94%, 80%, and 85%, respectively. In patients with AS and normal ejection fraction, annular tissue Doppler echocardiographic indices may better reflect the physiologic consequences of afterload burden on the left ventricle than body surface area-indexed aortic valve area. Lower A' velocity is a predictor of cardiac death and need for valve surgery, suggesting an important role for compensatory left atrial booster pump function.

  19. Role of LA Shape in Predicting Embolic Cerebrovascular Events in Mitral Stenosis

    PubMed Central

    Nunes, Maria Carmo P.; Handschumacher, Mark D.; Levine, Robert A.; Barbosa, Marcia M.; Carvalho, Vinicius T.; Esteves, William A.; Zeng, Xin; Guerrero, J. Luis; Zheng, Hui; Tan, Timothy C.; Hung, Judy

    2015-01-01

    OBJECTIVES This study was designed to assess the role of left atrial (LA) shape in predicting embolic cerebrovascular events (ECE) in patients with mitral stenosis (MS). BACKGROUND Patients with rheumatic MS are at increased risk for ECE. LA remodeling in response to MS involves not only chamber dilation but also changes in the shape. We hypothesized that a more spherical LA shape may be associated with increased embolic events due to predisposition to thrombus formation or to atrial arrhythmias compared with an elliptical-shaped LA of comparable volume. METHODS A total of 212 patients with MS and 20 control subjects were enrolled. LA volume, LA emptying fraction, and cross-sectional area were measured by 3-dimensional (3D) transthoracic echocardiography. LA shape was expressed as the ratio of measured LA end-systolic volume to hypothetical sphere volume ([4/3π r3] where r was obtained from 3D cross-sectional area). The lower the LA shape index, the more spherical the shape. RESULTS A total of 41 patients presented with ECE at the time of enrollment or during follow-up. On multivariate analysis, LA 3D emptying fraction (adjusted odds ratio [OR]: 0.96; 95% confidence interval [CI]: 0.92 to 0.99; p = 0.028) and LA shape index (OR: 0.73; 95% CI: 0.61 to 0.87; p < 0.001) emerged as important factors associated with ECE, after adjustment for age and anticoagulation therapy. In patients in sinus rhythm, LA shape index remained associated with ECE (OR: 0.79; 95% CI: 0.67 to 0.94; p = 0.007), independent of age and LA function. An in vitro phantom atrial model demonstrated more stagnant flow profiles in spherical compared with ellipsoidal chamber. CONCLUSIONS In rheumatic MS patients, differential LA remodeling affects ECE risk. A more spherical LA shape was independently associated with an increased risk for ECE, adding incremental value in predicting events beyond that provided by age and LA function. PMID:24831206

  20. Left atrial enlargement increases the risk of major adverse cardiac events independent of coronary vasodilator capacity.

    PubMed

    Koh, Angela S; Murthy, Venkatesh L; Sitek, Arkadiusz; Gayed, Peter; Bruyere, John; Wu, Justina; Di Carli, Marcelo F; Dorbala, Sharmila

    2015-09-01

    Longstanding uncontrolled atherogenic risk factors may contribute to left atrial (LA) hypertension, LA enlargement (LAE) and coronary vascular dysfunction. Together they may better identify risk of major adverse cardiac events (MACE). The aim of this study was to test the hypothesis that chronic LA hypertension as assessed by LAE modifies the relationship between coronary vascular function and MACE. In 508 unselected subjects with a normal clinical (82)Rb PET/CT, ejection fraction ≥40 %, no prior coronary artery disease, valve disease or atrial fibrillation, LAE was determined based on LA volumes estimated from the hybrid perfusion and CT transmission scan images and indexed to body surface area. Absolute myocardial blood flow and global coronary flow reserve (CFR) were calculated. Subjects were systematically followed-up for the primary end-point - MACE - a composite of all-cause death, myocardial infarction, hospitalization for heart failure, stroke, coronary artery disease progression or revascularization. During a median follow-up of 862 days, 65 of the subjects experienced a composite event. Compared with subjects with normal LA size, subjects with LAE showed significantly lower CFR (2.25 ± 0.83 vs. 1.95 ± 0.80, p = 0.01). LAE independently and incrementally predicted MACE even after accounting for clinical risk factors, medication use, stress left ventricular ejection fraction, stress left ventricular end-diastolic volume index and CFR (chi-squared statistic increased from 30.9 to 48.3; p = 0.001). Among subjects with normal CFR, those with LAE had significantly worse event-free survival (risk adjusted HR 5.4, 95 % CI 2.3 - 12.8, p < 0.0001). LAE and reduced CFR are related but distinct cardiovascular adaptations to atherogenic risk factors. LAE is a risk marker for MACE independent of clinical factors and left ventricular volumes; individuals with LAE may be at risk of MACE despite normal coronary vascular function.

  1. Global longitudinal strain corrected by RR interval is a superior predictor of all-cause mortality in patients with systolic heart failure and atrial fibrillation.

    PubMed

    Modin, Daniel; Sengeløv, Morten; Jørgensen, Peter Godsk; Bruun, Niels Eske; Olsen, Flemming Javier; Dons, Maria; Fritz Hansen, Thomas; Jensen, Jan Skov; Biering-Sørensen, Tor

    2018-04-01

    Quantification of systolic function in patients with atrial fibrillation (AF) is challenging. A novel approach, based on RR interval correction, to counteract the varying heart cycle lengths in AF has recently been proposed. Whether this method is superior in patients with systolic heart failure (HFrEF) with AF remains unknown. This study investigates the prognostic value of RR interval-corrected peak global longitudinal strain {GLSc = GLS/[RR^(1/2)]} in relation to all-cause mortality in HFrEF patients displaying AF during echocardiographic examination. Echocardiograms from 151 patients with HFrEF and AF during examination were analysed offline. Peak global longitudinal strain (GLS) was averaged from 18 myocardial segments obtained from three apical views. GLS was indexed with the square root of the RR interval {GLSc = GLS/[RR^(1/2)]}. Endpoint was all-cause mortality. During a median follow-up of 2.7 years, 40 patients (26.5%) died. Neither uncorrected GLS (P = 0.056) nor left ventricular ejection fraction (P = 0.053) was significantly associated with all-cause mortality. After RR^(1/2) indexation, GLSc became a significant predictor of all-cause mortality (hazard ratio 1.16, 95% confidence interval 1.02-1.22, P = 0.014, per %/s^(1/2) decrease). GLSc remained an independent predictor of mortality after multivariable adjustment (age, sex, mean heart rate, mean arterial blood pressure, left atrial volume index, and E/e') (hazard ratio 1.17, 95% confidence interval 1.05-1.31, P = 0.005 per %/s^(1/2) decrease). Decreasing {GLSc = GLS/[RR^(1/2)]}, but not uncorrected GLS nor left ventricular ejection fraction, was significantly associated with increased risk of all-cause mortality in HFrEF patients with AF and remained an independent predictor after multivariable adjustment. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.

  2. Association of Circulating Adipokines With Echocardiographic Measures of Cardiac Structure and Function in a Community-Based Cohort.

    PubMed

    von Jeinsen, Beatrice; Short, Meghan I; Xanthakis, Vanessa; Carneiro, Herman; Cheng, Susan; Mitchell, Gary F; Vasan, Ramachandran S

    2018-06-21

    Adipokines mediate cardiometabolic risk associated with obesity but their role in the pathogenesis of obesity-associated heart failure remains uncertain. We investigated the associations between circulating adipokine concentrations and echocardiographic measures in a community-based sample. We evaluated 3514 Framingham Heart Study participants (mean age 40 years, 53.8% women) who underwent routine echocardiography and had select circulating adipokines measured, ie, leptin, soluble leptin receptor, fatty acid-binding protein 4, retinol-binding protein 4, fetuin-A, and adiponectin. We used multivariable linear regression, adjusting for known correlates (including weight), to relate adipokine concentrations (independent variables) to the following echocardiographic measures (dependent variables): left ventricular mass index, left atrial diameter in end systole, fractional shortening, and E/e'. In multivariable-adjusted analysis, left ventricular mass index was inversely related to circulating leptin and fatty acid-binding protein 4 concentrations but positively related to retinol-binding protein 4 and leptin receptor levels ( P ≤0.002 for all). Left atrial end-systolic dimension was inversely related to leptin but positively related to retinol-binding protein 4 concentrations ( P ≤0.0001). E/e' was inversely related to leptin receptor levels ( P =0.0002). We observed effect modification by body weight for select associations (leptin receptor and fatty acid-binding protein 4 with left ventricular mass index, and leptin with left atrial diameter in end systole; P <0.05 for interactions). Fractional shortening was not associated with any of the adipokines. No echocardiographic trait was associated with fetuin-A or adiponectin concentrations. In our cross-sectional study of a large, young to middle-aged, relatively healthy community-based sample, key indices of subclinical cardiac remodeling were associated with higher or lower circulating concentrations of prohypertrophic and antihypertrophic adipokines in a context-specific manner. These observations may offer insights into the pathogenesis of the cardiomyopathy of obesity. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  3. Phenotyping of Sleep-Disordered Breathing in Patients With Chronic Heart Failure With Reduced Ejection Fraction-the SchlaHF Registry.

    PubMed

    Arzt, Michael; Oldenburg, Olaf; Graml, Andrea; Erdmann, Erland; Teschler, Helmut; Wegscheider, Karl; Suling, Anna; Woehrle, Holger

    2017-11-29

    Different sleep-disordered breathing (SDB) phenotypes, including coexisting obstructive and central sleep apnea (OSA-CSA), have not yet been characterized in a large sample of patients with heart failure and reduced ejection fraction (HFrEF) receiving guideline-based therapies. Therefore, the aim of the present study was to determine the proportion of OSA, CSA, and OSA-CSA, as well as periodic breathing, in HFrEF patients with SDB. The German SchlaHF registry enrolled patients with HFrEF receiving guideline-based therapies, who underwent portable SDB monitoring. Polysomnography (n=2365) was performed in patients with suspected SDB. Type of SDB (OSA, CSA, or OSA-CSA), the occurrence of periodic breathing (proportion of Cheyne-Stokes respiration ≥20%), and blood gases were determined in 1557 HFrEF patients with confirmed SDB. OSA, OSA-CSA, and CSA were found in 29%, 40%, and 31% of patients, respectively; 41% showed periodic breathing. Characteristics differed significantly among SDB groups and in those with versus without periodic breathing. There was a relationship between greater proportions of CSA and the presence of periodic breathing. Risk factors for having CSA rather than OSA were male sex, older age, presence of atrial fibrillation, lower ejection fraction, and lower awake carbon dioxide pressure (pco 2 ). Periodic breathing was more likely in men, patients with atrial fibrillation, older patients, and as left ventricular ejection fraction and awake pco 2 decreased, and less likely as body mass index increased and minimum oxygen saturation decreased. SchlaHF data show that there is wide interindividual variability in the SDB phenotype of HFrEF patients, suggesting that individualized management is appropriate. URL: https://www.clinicaltrials.gov/. Unique identifier: NCT01500759. © 2017 The Authors and ResMed Germany Inc. Published on behalf of the American Heart Association, Inc., by Wiley.

  4. Relationship between mitral annulus function and mitral regurgitation severity and left atrial remodelling in patients with primary mitral regurgitation.

    PubMed

    Mihaila, Sorina; Muraru, Denisa; Miglioranza, Marcelo Haertel; Piasentini, Eleonora; Aruta, Patrizia; Cucchini, Umberto; Iliceto, Sabino; Vinereanu, Dragos; Badano, Luigi P

    2016-08-01

    To explore the relationship between the mitral annular (MA) remodelling and dysfunction, mitral regurgitation (MR) severity, left ventricular (LV) and atrial (LA) size and function in patients with organic MR (OMR). A total of 52 patients (57 ± 15 years, 31 men) with mild to severe OMR and 52 controls underwent 3D transthoracic echocardiography acquisitions of the mitral valve (MV), LA, and LV. MA geometry and dynamics, LV and LA volumes, LV ejection fraction (LVEF) and emptying fractions (LAEF) were assessed using dedicated software packages. LA and LV myocardial deformations were assessed using 2D speckle-tracking echocardiography. OMR patients presented larger and more spherical MA than controls during the entire systole (P < 0.001). Although the MA non-planarity at early-systole was similar between OMR and controls (157 ± 13° vs. 153 ± 12°, P = NS), the MA became flatter from mid- to end-systole (153 ± 12 vs. 146 ± 10° and 157 ± 12 vs. 147 ± 8°, P < 0.01) in OMR. MA area fractional change was lower in patients with OMR (22 ± 5% vs. 28 ± 5%, P < 0.001), and correlated with the MR orifice and volume (r = -0.52 and r = -0.55). MA fractional area change correlated with LA minimum and maximum volumes (r = 0.77 and r = 0.70), total and active LAEF (r = 0.72 and r = 0.76), and LA negative strain and strain rate (r = 0.52 and r = 0.57), but not with the LVEF or LV global longitudinal strain. In a multivariate regression model using LAEF and LVEF, solely active LAEF correlated with the MA fractional area change (β = 0.51, P = 0.005). In patients with OMR, MA reduced function correlates with the MR severity and the LA size and function, but not with the LV function. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. M-Mode Echocardiographic Changes in Growing Beagles

    PubMed Central

    Diez-Prieto, Inmaculada; García-Rodríguez, M Belén; Ríos-Granja, M Angeles; Cano-Rábano, María J; Peña-Penabad, Marina; Pérez-García, Carlos C

    2010-01-01

    Heart growth in 6 female beagle dogs was measured by using M-mode echocardiography at 4, 7, 10, 13, 17, and 21 mo of age. The same 6 dogs were evaluated throughout the study to establish when cardiac development ends in this breed. The following parameters were measured during systole and diastole: left ventricle posterior wall thickness, interventricular septal thickness, left ventricular internal dimension, left atrial dimension during ventricular systole, aortic root dimension at end diastole, E-point to septal separation, left ventricular preejection period, ejection time of the left ventricular outflow, and time between the cessation and onset of the mitral inflow intervals. The percentage of the left ventricle posterior wall thickening, fractional shortening, ejection fraction, left ventricular end systolic and end-diastolic volumes, ratio of the left atrial dimension to aortic root dimension, and the Tei index of myocardial performance were calculated. The heart rate was measured by cardiac auscultation. The influence of ageing on each echocardiographic parameter and relationships with body weight and surface were studied. Results show that cardiac development in female beagles can be considered finished by the age of 1 y, perhaps as soon as 7 mo. The cardiac indexes studied were unaffected by the age and corporal dimensions, confirming the usefulness of these parameters for evaluating cardiac functionality alterations independent of a dog's age and body weight or surface area. PMID:20122313

  6. Optimal Analysis of Left Atrial Strain by Speckle Tracking Echocardiography: P-wave versus R-wave Trigger.

    PubMed

    Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka

    2015-08-01

    Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.

  7. Gender related differences in clinical profile and outcome of patients with heart failure. Results of the RICA Registry.

    PubMed

    Conde-Martel, A; Arkuch, M E; Formiga, F; Manzano-Espinosa, L; Aramburu-Bodas, O; González-Franco, Á; Dávila-Ramos, M F; Suárez-Pedreira, I; Herrero-Domingo, A; Montero-Pérez-Barquero, M

    2015-10-01

    To analyze the differential clinical characteristics according to gender of patients with heart failure in terms of etiology, comorbidity, triggers, treatment, hospital stay and overall mortality at one year. We employed data from the RICA registry, a multicenter prospective cohort of patients hospitalized in internal medicine departments for heart failure, with a follow-up of one year. We analyzed the differences between the gender in terms of the etiology of the heart disease, comorbidity, triggers, left ventricle ejection fraction, functional state, mental condition, treatment, length of stay and mortality at 1 year. A total of 1772 patients (47.2% men) were included. The women were older than the men (p<.001) and had a higher prevalence of hypertension, obesity, chronic kidney disease, atrial fibrillation and preserved left ventricle ejection fraction (p<.001). The men's medical history had a predominance of myocardial infarction, chronic obstructive pulmonary disease, peripheral arteriopathy (p<.001) and anemia (p=.02). In the women, a hypertensive etiology was predominant, followed by valvular. The main triggers were hypertension and atrial fibrillation. Treatment with beta-blockers, ACEIs and/or ARBs did not differ by sex. The women had poorer functional capacity (p<.001), according to the Barthel index. After adjusting for age and other prognostic factors, the mortality at one year was lower among the women (RR: 0.69; 95% CI 0.53-0.89; p=.004). HF in women occurs at a later age and with different comorbidities. The hypertensive and valvular etiology is predominant, with preserved left ventricle ejection fraction, and the age-adjusted mortality is lower than in men. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  8. Heart rate and outcome in heart failure with reduced ejection fraction: Differences between atrial fibrillation and sinus rhythm-A CIBIS II analysis.

    PubMed

    Mulder, Bart A; Damman, Kevin; Van Veldhuisen, Dirk J; Van Gelder, Isabelle C; Rienstra, Michiel

    2017-09-01

    Heart rate has been associated with prognosis in patients with heart failure with reduced ejection fraction (HFREF) and sinus rhythm; whether this also holds true in patients with atrial fibrillation (AF) is unknown. To evaluate cardiac rhythm and baseline heart rate and the influence of outcome in patients with HFREF enrolled in the Cardiac Insufficiency Bisoprolol Study II. In total, 2539 patients were stratified according to their baseline heart rhythm (AF or sinus rhythm) and into quartiles of heart rate (≤70 bpm, 71-78 bpm, 79-90 bpm, and >90 bpm). The primary outcome was all-cause mortality. Mean follow-up was 1.3 years. Mean age was 61 years, mean left ventricular ejection fraction was 28%, and 80% were male. A total of 521 (21%) patients had AF at baseline. The risk associated with all-cause mortality for each 5 bpm increase in heart rate in patients with sinus rhythm (hazard ratio [HR]: 1.06, 95% confidence interval [CI]: 1.01-1.11, P = 0.012) was significantly different from those with AF (HR: 1.00, 95% CI: 0.94-1.07, P = 0.90, P for interaction = 0.041). The risk associated with higher heart rate in sinus rhythm was primarily attributable to excess risk in the highest quartile (HR: 1.64, 95% CI: 1.18-2.30, P = 0.003). Allocation to bisoprolol did not modify the interaction between heart rate, rhythm and outcome. In HFREF patients with AF, a higher heart rate is not associated with increased event rates in contrast to HFREF patients with sinus rhythm. © 2017 Wiley Periodicals, Inc.

  9. Intra-aortic balloon pumping in acute mitral regurgitation reduces aortic impedance and regurgitant fraction.

    PubMed

    Dekker, André L A J; Reesink, Koen D; van der Veen, Frederik H; van Ommen, G Vincent A; Geskes, Gijs G; Soemers, A Cecilia M; Maessen, Jos G

    2003-04-01

    Acute mitral regurgitation (MR) is present in 10% of patients presenting with cardiogenic shock. To stabilize these patients, intra-aortic balloon pumping (IABP) is recommended, but the mechanism of IABP support in these patients is unknown. This animal study was designed to describe the hemodynamic effect of intra-aortic balloon pumping during cardiogenic shock induced by acute MR. In eight calves, left ventricular pressure-volume loops, aortic and left atrial pressure, and aortic, carotid artery, and coronary blood flow were recorded. Acute MR (range 36%-79%) was created by placing a metal cage in the mitral valve. Hemodynamic data was obtained at control, during acute MR, and during acute MR with 1:1 IABP support. Acute MR caused a decrease in cardiac output (-32%, P = 0.018), blood pressure, and carotid artery flow, whereas left ventricular output (+127%, P = 0.018), end-diastolic volume, and left atrial pressure all significantly increased. Stroke work, ejection fraction, and coronary blood flow were not significantly changed, and no signs of ischemia were seen on the ECG. The IABP raised average cardiac output by 31% (P = 0.012) and significantly raised blood pressure and flow to the brain while decreasing systemic vascular resistance. Left ventricular function and mean coronary blood flow did not change, but diastolic coronary flow became more important as shown by the increase in diastolic fraction from 64% to 95%. (P = 0.028). Average MR dropped by 7.5% (P = 0.025). In conclusion, application of the IABP during acute MR lowers aortic impedance, resulting in less MR and more output toward the aorta without changing left ventricular function.

  10. Left atrial appendage segmentation and quantitative assisted diagnosis of atrial fibrillation based on fusion of temporal-spatial information.

    PubMed

    Jin, Cheng; Feng, Jianjiang; Wang, Lei; Yu, Heng; Liu, Jiang; Lu, Jiwen; Zhou, Jie

    2018-05-01

    In this paper, we present an approach for left atrial appendage (LAA) multi-phase fast segmentation and quantitative assisted diagnosis of atrial fibrillation (AF) based on 4D-CT data. We take full advantage of the temporal dimension information to segment the living, flailed LAA based on a parametric max-flow method and graph-cut approach to build 3-D model of each phase. To assist the diagnosis of AF, we calculate the volumes of 3-D models, and then generate a "volume-phase" curve to calculate the important dynamic metrics: ejection fraction, filling flux, and emptying flux of the LAA's blood by volume. This approach demonstrates more precise results than the conventional approaches that calculate metrics by area, and allows for the quick analysis of LAA-volume pattern changes of in a cardiac cycle. It may also provide insight into the individual differences in the lesions of the LAA. Furthermore, we apply support vector machines (SVMs) to achieve a quantitative auto-diagnosis of the AF by exploiting seven features from volume change ratios of the LAA, and perform multivariate logistic regression analysis for the risk of LAA thrombosis. The 100 cases utilized in this research were taken from the Philips 256-iCT. The experimental results demonstrate that our approach can construct the 3-D LAA geometries robustly compared to manual annotations, and reasonably infer that the LAA undergoes filling, emptying and re-filling, re-emptying in a cardiac cycle. This research provides a potential for exploring various physiological functions of the LAA and quantitatively estimating the risk of stroke in patients with AF. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Left Atrial Size, Chemosensitivity, and Central Sleep Apnea in Heart Failure

    PubMed Central

    Calvin, Andrew D.; Somers, Virend K.; Johnson, Bruce D.; Scott, Christopher G.

    2014-01-01

    BACKGROUND: Central sleep apnea (CSA) is common among patients with heart failure (HF) and is promoted by elevated CO2 chemosensitivity. Left atrial size is a marker of the hemodynamic severity of HF. The aim of this study was to determine if left atrial size predicts chemosensitivity to CO2 and CSA in patients with HF. METHODS: Patients with HF with left ventricular ejection fraction ≤ 35% underwent polysomnography for detection of CSA, echocardiography, and measurement of CO2 chemosensitivity. CSA was defined as an apnea-hypopnea index (AHI) ≥ 15/h with ≥ 50% central apneic events. The relation of clinical and echocardiographic parameters to chemosensitivity and CSA were evaluated by linear regression, estimation of ORs, and receiver operator characteristics. RESULTS: Of 46 subjects without OSA who had complete data for analysis, 25 had CSA. The only parameter that significantly correlated with chemosensitivity was left atrial volume index (LAVI) (r = 0.40, P < .01). LAVI was greater in those with CSA than those without CSA (59.2 mL/m2 vs 36.4 mL/m2, P < .001) and significantly correlated with log-transformed AHI (r = 0.46, P = .001). LAVI was the best predictor of CSA (area under the curve = 0.83). A LAVI ≤ 33 mL/m2 was associated with 22% risk for CSA, while LAVI ≥ 53 mL/m2 was associated with 92% risk for CSA. CONCLUSIONS: Increased LAVI is associated with heightened CO2 chemosensitivity and greater frequency of CSA. LAVI may be useful to guide referral for polysomnography for detection of CSA in patients with HF. PMID:24522490

  12. Cardiac resynchronization therapy and atrial overdrive pacing for the treatment of central sleep apnoea

    PubMed Central

    Lüthje, Lars; Renner, Bernd; Kessels, Roger; Vollmann, Dirk; Raupach, Tobias; Gerritse, Bart; Tasci, Selcuk; Schwab, Jörg O.; Zabel, Markus; Zenker, Dieter; Schott, Peter; Hasenfuss, Gerd; Unterberg-Buchwald, Christina; Andreas, Stefan

    2009-01-01

    Aims The combined therapeutic impact of atrial overdrive pacing (AOP) and cardiac resynchronization therapy (CRT) on central sleep apnoea (CSA) in chronic heart failure (CHF) so far has not been investigated. We aimed to evaluate the effect of CRT alone and CRT + AOP on CSA in CHF patients and to compare the influence of CRT on CHF between CSA positive and CSA negative patients. Methods and results Thirty patients with CRT indication underwent full night polysomnography, echocardiography, exercise testing, and neurohumoral evaluation before and 3 months after CRT implantation. In CSA positive patients (60%), two additional sleep studies were conducted after 3 months of CRT, with CRT alone or CRT + AOP, in random order. Cardiac resynchronization therapy resulted in significant improvements of NYHA class, left ventricular ejection fraction, N-terminal pro-brain natriuretic peptide, VO2max, and quality of life irrespective of the presence of CSA. Cardiac resynchronization therapy also reduced the central apnoea–hypopnoea index (AHI) (33.6 ± 14.3 vs. 23.8 ± 16.9 h−1; P < 0.01) and central apnoea index (17.3 ± 14.1 vs. 10.9 ± 13.9 h−1; P < 0.01) without altering sleep stages. Cardiac resynchronization therapy with atrial overdrive pacing resulted in a small but significant additional decrease of the central AHI (23.8 ± 16.9 vs. 21.5 ± 16.9 h−1; P < 0.01). Conclusion In this study, CRT significantly improved CSA without altering sleep stages. Cardiac resynchronization therapy with atrial overdrive pacing resulted in a significant but minor additional improvement of CSA. Positive effects of CRT were irrespective of the presence of CSA. PMID:19147446

  13. Impaired left atrial function predicts inappropriate shocks in primary prevention implantable cardioverter-defibrillator candidates.

    PubMed

    Tao, Susumu; Ashikaga, Hiroshi; Ciuffo, Luisa A; Yoneyama, Kihei; Lima, Joao A C; Frank, Terry F; Weiss, Robert G; Tomaselli, Gordon F; Wu, Katherine C

    2017-07-01

    Inappropriate implantable cardioverter-defibrillator (ICD) shocks, commonly caused by atrial fibrillation (AF), are associated with an increased mortality. Because impaired left atrial (LA) function predicts development of AF, we hypothesized that impaired LA function predicts inappropriate shocks beyond a history of AF. We prospectively analyzed the association between LA function and incident inappropriate shocks in primary prevention ICD candidates. In the Prospective Observational Study of ICD (PROSE-ICD), we assessed LA function using tissue-tracking cardiac magnetic resonance (CMR) prior to ICD implantation. A total of 162 patients (113 males, age 56 ± 15 years) were included. During the mean follow-up of 4.0 ± 2.9 years, 26 patients (16%) experienced inappropriate shocks due to AF (n = 19; 73%), supraventricular tachycardia (n = 5; 19%), and abnormal sensing (n = 2; 8%). In univariable analyses, inappropriate shocks were associated with AF history prior to ICD implantation, age below 70 years, QRS duration less than 120 milliseconds, larger LA minimum volume, lower LA stroke volume, lower LA emptying fraction, impaired LA maximum and preatrial contraction strains (S max and S preA ), and impaired LA strain rate during left ventricular systole and atrial contraction (SR s and SR a ). In multivariable analysis, impaired S max (hazard ratio [HR]: 0.96, P = 0.044), S preA (HR: 0.94, P = 0.030), and SR a (HR: 0.25, P < 0.001) were independently associated with inappropriate shocks. The receiver-operating characteristics curve showed that SR a improved the predictive value beyond the patient demographics including AF history (P = 0.033). Impaired LA function assessed by tissue-tracking CMR is an independent predictor of inappropriate shocks in primary prevention ICD candidates beyond AF history. © 2017 Wiley Periodicals, Inc.

  14. Different effects of prolonged exercise on the right and left ventricles.

    PubMed

    Douglas, P S; O'Toole, M L; Hiller, W D; Reichek, N

    1990-01-01

    To examine the functional consequences of the greater increase in right ventricular work with exercise, the effects of prolonged exercise on the right and left heart chambers were compared in 41 athletes before, at the finish (13 min) and after recovery (28 h) from the Hawaii Ironman Triathlon (3.9 km swim, 180.2 km bike ride, 42.2 km run). Two-dimensional and Doppler echocardiograms were analyzed for left and right atrial and ventricular areas at end-diastole and end-systole, right and left ventricular inflow velocities and mitral and tricuspid regurgitation. After exercise, left ventricular and left and right atrial sizes were reduced, whereas right ventricular size increased (diastole: 21.4 to 24.2 cm2; systole: 15.8 to 18.2 cm2; p less than 0.01). The emptying fraction of all chambers was unchanged. Left but not right ventricular inflow showed an increase in peak velocity of rapid filling, whereas both atrial systolic velocities increased (26 to 38 cm/s tricuspid; 38 to 54 cm/s mitral; both p less than 0.01). Overall, the right ventricular early to atrial velocity ratio was reduced after exercise (1.56 to 1.17; p less than 0.05) and the left ventricular pattern was unchanged. The prevalence of tricuspid regurgitation was statistically unchanged (86% to 52%), although that of mitral regurgitation was greatly reduced (76% to 0%). Changes in all variables returned toward prerace values during recovery. Thus, in highly trained athletes, prolonged exercise causes differing responses of the right and left ventricles. These differences may be due to changes in right ventricular function, shape or compliance.

  15. Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure: Rationale and Design of the Randomized Trial to REDUCE Elevated Left Atrial Pressure in Heart Failure (REDUCE LAP-HF I).

    PubMed

    Feldman, Ted; Komtebedde, Jan; Burkhoff, Daniel; Massaro, Joseph; Maurer, Mathew S; Leon, Martin B; Kaye, David; Silvestry, Frank E; Cleland, John G F; Kitzman, Dalane; Kubo, Spencer H; Van Veldhuisen, Dirk J; Kleber, Franz; Trochu, Jean-Noël; Auricchio, Angelo; Gustafsson, Finn; Hasenfuβ, Gerd; Ponikowski, Piotr; Filippatos, Gerasimos; Mauri, Laura; Shah, Sanjiv J

    2016-07-01

    Heart failure with preserved ejection fraction (HFpEF), a major public health problem with high morbidity and mortality rates, remains difficult to manage because of a lack of effective treatment options. Although HFpEF is a heterogeneous clinical syndrome, elevated left atrial pressure-either at rest or with exertion-is a common factor among all forms of HFpEF and one of the primary reasons for dyspnea and exercise intolerance in these patients. On the basis of clinical experience with congenital interatrial shunts in mitral stenosis, it has been hypothesized that the creation of a left-to-right interatrial shunt to decompress the left atrium (without compromising left ventricular filling or forward cardiac output) is a rational, nonpharmacological strategy for alleviating symptoms in patients with HFpEF. A novel transcatheter interatrial shunt device has been developed and evaluated in patients with HFpEF in single-arm, nonblinded clinical trials. These studies have demonstrated the safety and potential efficacy of the device. However, a randomized, placebo-controlled evaluation of the device is required to further evaluate its safety and efficacy in patients with HFpEF. In this article, we give the rationale for a therapeutic transcatheter interatrial shunt device in HFpEF, and we describe the design of REDUCE Elevated Left Atrial Pressure in Heart Failure (REDUCE LAP-HF I), the first randomized controlled trial of a device-based therapy to reduce left atrial pressure in HFpEF. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02600234. © 2016 American Heart Association, Inc.

  16. Changes in Left Atrial Transport Function in Patients Who Maintained Sinus Rhythm After Successful Radiofrequency Catheter Ablation for Atrial Fibrillation: A 1-Year Follow-Up Multislice Computed Tomography Study.

    PubMed

    Kim, Jin-Seok; Im, Sung Il; Shin, Seung Yong; Kang, Jun Hyuk; Na, Jin Oh; Choi, Cheol Ung; Kim, Seong Hwan; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo; Hwang, Chun; Kim, Young-Hoon; Yong, Hwan Seok; Lim, Hong Euy

    2017-02-01

    Functional remodeling of left atrium (LA) after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) has not been fully elucidated. This study aimed to determine the impact of RFCA on LA transport function in patients who maintained sinus rhythm (SR) after AF ablation. A total of 96 patients (paroxysmal AF [PAF] = 52) who maintained SR during 1 year after AF ablation were enrolled. Multislice computed tomography was performed to determine LA volume (LAV) and LA emptying fraction (LAEF) at pre-RFCA and 1-year post-RFCA. Creatine kinase-MB (CK-MB) and troponin-T levels were analyzed 1-day post-RFCA. At 1-year post-RFCA, mean LAV and LAEF decreased in overall patients. Based on LAEF change (ΔLAEF) cutoff of 5.0%, LAEF reduced in 41 patients (worsened group) and improved or showed no change in 55 patients (preserved group). Compared with preserved group, worsened group had a higher proportion of PAF, higher levels of CK-MB and troponin-T, and additional LA ablation. ΔLAEF was inversely correlated with CK-MB and troponin-T levels. Subgroup analysis showed that LAEF significantly decreased in PAF patients who underwent additional LA ablation. Multivariate analysis revealed that high baseline LAEF and additional LA ablation were independent predictors for worsened LAEF. Although SR was maintained for 1 year after AF ablation, LAEF as well as LAV decreased. The extent of LAEF deterioration was significantly associated with the amount of iatrogenic myocardial damage. Our data indicate that extensive atrial ablation may lead to LA functional deterioration, especially in patients with PAF. © 2016 Wiley Periodicals, Inc.

  17. Renal effects of continuous negative pressure breathing

    NASA Technical Reports Server (NTRS)

    Kinney, M. J.

    1975-01-01

    Continuous negative pressure breathing (CNPB) was utilized to simulate the thoracic vascular distension of zero G in 11 anesthetized rats. The animals underwent renal clearance and micropuncture renal nephron studies before, during, and after CNPB. Four rats were pretreated with a high salt diet and I-M desoxycorticosterone (DOCA) in excess. None of these rats diuresed with CNPB. In contrast, five of the seven remaining rats increased the fraction of the filtered sodium excreted and their urinary flow rate. Potassium excretion increased. End proximal tubular fluid specimen's TF/P inulin ratios were unchanged. Whole kidney and single nephron glomerular filtration rates fell 10%. CNPB, a mechanism for atrial distension, appears to cause in the rat a decrease in distal tubular sodium and water reabsorption. Exogenous mineral-corticoid prevents the diuresis, saluresis, and kaluresis. The adequacy of other nonatrial volume control mechanisms in regulating renal salt and water conservation in opposition to the studied atrial-renal (Henry-Gauer) reflex of thoracic vascular distension is confirmed.

  18. Methods for assisting recovery of damaged brain and spinal cord and treating various diseases using arrays of x-ray microplanar beams

    DOEpatents

    Dilmanian, F Avraham [Yaphank, NY; Anchel, David J [Rocky Point, NY; Gaudette, Glenn [Holden, MA; Romanelli, Pantaleo [Monteroduni, IT; Hainfeld, James [Shoreham, NY

    2010-06-29

    A method of assisting recovery of an injury site of the central nervous system (CNS) or treating a disease includes providing a therapeutic dose of X-ray radiation to a target volume through an array of parallel microplanar beams. The dose to treat CNS injury temporarily removes regeneration inhibitors from the irradiated site. Substantially unirradiated cells surviving between beams migrate to the in-beam portion and assist recovery. The dose may be staggered in fractions over sessions using angle-variable intersecting microbeam arrays (AVIMA). Additional doses are administered by varying the orientation of the beams. The method is enhanced by injecting stem cells into the injury site. One array or the AVIMA method is applied to ablate selected cells in a target volume associated with disease for palliative or curative effect. Atrial fibrillation is treated by irradiating the atrial wall to destroy myocardial cells while continuously rotating the subject.

  19. Efficacy of catheter ablation of atrial fibrillation beyond HATCH score.

    PubMed

    Tang, Ri-Bo; Dong, Jian-Zeng; Long, De-Yong; Yu, Rong-Hui; Ning, Man; Jiang, Chen-Xi; Sang, Cai-Hua; Liu, Xiao-Hui; Ma, Chang-Sheng

    2012-10-01

    HATCH score is an established predictor of progression from paroxysmal to persistent atrial fibrillation (AF). The purpose of this study was to determine if HATCH score could predict recurrence after catheter ablation of AF. The data of 488 consecutive paroxysmal AF patients who underwent an index circumferential pulmonary veins (PV) ablation were retrospectively analyzed. Of these patients, 250 (51.2%) patients had HATCH score = 0, 185 (37.9%) patients had HATCH score = 1, and 53 (10.9%) patients had HATCH score ≥ 2 (28 patients had HATCH score = 2, 23 patients had HATCH score = 3, and 2 patients had HATCH score = 4). The patients with HATCH score ≥ 2 had significantly larger left atrium size, the largest left ventricular end systolic diameter, and the lowest ejection fraction. After a mean follow-up of (823 ± 532) days, the recurrence rates were 36.4%, 37.8% and 28.3% from the HATCH score = 0, HATCH score = 1 to HATCH score ≥ 2 categories (P = 0.498). Univariate analysis revealed that left atrium size, body mass index, and failure of PV isolation were predictors of AF recurrence. After adjustment for body mass index, left atrial size and PV isolation, the HATCH score was not an independent predictor of recurrence (HR = 0.92, 95% confidence interval = 0.76 - 1.12, P = 0.406) in multivariate analysis. HATCH score has no value in prediction of AF recurrence after catheter ablation.

  20. Atrial stretch delays gastric emptying of liquids in awake rats.

    PubMed

    Palheta, R C; Silva, M T B; Barbosa, H L G; Pinheiro, A D N; Cardoso, K V V; Graça, J R V; Magalhães, P J C; Oliveira, R B; Santos, A A

    2013-03-21

    We previously reported that mechanical atrial stretch (AS) by balloon distention increased gastric tonus in anesthetized rats. The present study evaluated the effect of AS on the gastric emptying of a liquid test meal in awake rats and its underlying neural mechanisms. Anesthetized male rats received a balloon catheter into the right atrium and a gastrostomy cannula. The next day, mean arterial pressure (MAP), heart rate (HR), central venous pressure (CVP), and cardiac output (CO) were continuously monitored. After the first 20min of monitoring (basal interval), the balloon was either distended or not (control) with 30, 50, or 70μl saline for 5min. Fifteen minutes later, the rats received the test meal (glucose solution with phenol red), and fractional gastric dye retention was determined 10, 20, or 30min later. Heart rate and CVP values were transiently increased by 50 or 70μl AS but not 30μl AS, whereas gastric emptying was slower after 30, 50, or 70μl AS than after sham distention. Subdiaphragmatic vagotomy or splanchnicotomy+celiac ganglionectomy and capsaicin, ondansetron, hexamethonium, L-NAME, and glibenclamide treatment prevented the AS-induced delay in gastric emptying, whereas atropine and guanethidine treatment failed to prevent it. Atrial stretch inhibited the gastric emptying of liquid via non-adrenergic and non-cholinergic pathways that activate nitric oxide-K(+)ATP channels. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Right Ventricular Outflow Tract Septal Pacing Is Superior to Right Ventricular Apical Pacing

    PubMed Central

    Zou, Cao; Song, Jianping; Li, Hui; Huang, Xingmei; Liu, Yuping; Zhao, Caiming; Shi, Xin; Yang, Xiangjun

    2015-01-01

    Background The effects of right ventricular apical pacing (RVAP) and right ventricular outflow tract (RVOT) septal pacing on atrial and ventricular electrophysiology have not been thoroughly compared. Methods and Results To identify a more favorable pacing strategy with fewer adverse effects, 80 patients who had complete atrioventricular block with normal cardiac function and who were treated with either RVAP (n=42) or RVOT septal pacing (n=38) were recruited after an average of 2 years of follow‐up. The data from electrocardiography and echocardiography performed before pacemaker implantation and at the end of follow‐up were collected. The patients in the RVOT septal pacing and RVAP groups showed similar demographic and clinical characteristics before pacing treatments. After a mean follow‐up of 2 years, the final maximum P‐wave duration; P‐wave dispersion; Q‐, R‐, and S‐wave complex duration; left atrial volume index; left ventricular end‐systolic diameter; ratio of transmitral early diastolic filling velocity to mitral annular early diastolic velocity; and interventricular mechanical delay in the RVOT septal pacing group were significantly less than those in the RVAP group (P<0.05). The final left ventricular ejection fraction of the RVOT septal pacing group was significantly higher than that of the RVAP group (P<0.05). Conclusions Compared with RVAP, RVOT septal pacing has fewer adverse effects regarding atrial electrical activity and structure in patients with normal cardiac function. PMID:25896891

  2. Right atrial isolation associated with atrial septal closure in patients with atrial septal defect and chronic atrial fibrillation.

    PubMed

    Minzioni, G; Graffigna, A; Pagani, F; Vigano, M

    1993-12-01

    To restore sinus rhythm in the remaining heart chambers of six adult patients with atrial septal defect and chronic or paroxysmal atrial fibrillation, electrical, right atrial isolation associated with surgical correction of the defect was performed. All but one patient was free from atrial fibrillation without medication 2-25 months after operation. The isolated right atrial appendages showed intrinsic rhythmical activity in five patients and no electrical activity in one. Right atrial isolation is a safe and effective procedure that abolishes atrial fibrillation in patients with arrhythmia after surgical correction of atrial septal defect.

  3. Atrial fibrillation and hyperthyroidism: A literature review.

    PubMed

    Reddy, Vivek; Taha, Wael; Kundumadam, Shanker; Khan, Mazhar

    Atrial fibrillation is the most common arrhythmia worldwide with increasing frequency noted with age. Hyperthyroidism is a well-known cause of atrial fibrillation with a 16%-60% prevalence of atrial fibrillation in patients with known hyperthyroidism Ross et al. (2016). While hyperthyroidism as a causative factor of atrial fibrillation is well established, this literature review aims to answer several questions on this topic including: 1. The relationship of atrial fibrillation to hyperthyroidism 2. Atrial fibrillation as a predictor of hyperthyroidism 3. The pathophysiology of thyrotoxic atrial fibrillation 4. Subclinical hyperthyroidism and the relationship with atrial fibrillation 5. Cardioversion and Catheter ablation of hyperthyroid patients with atrial fibrillation 6. Thrombotic risk of hyperthyroid patients with atrial fibrillation 7. Management of Thyrotoxic Atrial fibrillation 8. Pharmacological rhythm control in patients with hyperthyroidism and atrial fibrillation 9. Treatment of Hyperthyroidism to prevent atrial fibrillation 10. Clinical Implications of Hyperthyroidism and Atrial Fibrillation. Copyright © 2017 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  4. Three-dimensional echocardiographic measurements using automated quantification software for big data processing.

    PubMed

    Feng, Cheng; Chen, Lixin; Li, Jian; Wang, Jiangtao; Dong, Fajin; Xu, Jinfeng

    2017-01-01

    To compare a full-automated software to quantify 3D transthoracic echocardiography namely, 3DE-HM (three-dimensional echocardiography HeartModel, Philips Healthcare) with the traditional manual quantitative method (3DE-manual) for assessing volumes of left atrial and ventricular volumes, and left ventricular ejection fraction (LVEF). 3D full volume images acquired from 156 subjects were collected and divided into 3 groups, which include 70 normal control cases (Group A), 17 patients with left ventricular remodeling after acute myocardial infarction (AMI) (Group B), and 69 patients with left atrial remodeling secondary to hypertension (Group C). The 3DE-HM method was used to quantify left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left atrial end-systolic volume (LAESV), and left ventricular ejection fraction (LVEF), respectively. The results were compared with those obtained with the 3DE-manual method for correlation and consistency analyses. The reproducibility of the 3DE-HM method was also evaluated. There was a high correlation between LVEDV, LVESV, LAESV and LVEF values obtained with the 3DE-HM method and those obtained using the 3DE-manual method (r = 0.72 to 0.97). The correlation was strongest for Group B, patients with left ventricular remodeling post-AMI also demonstrated the greatest degree of morphologic changes. There was a significant difference in all parameters measured with the 3DE-HM method in different groups (P < 0.05). The difference in the measurements of LVEDV and LVESV between the two methods was greatest in patients in Group B compared with patients with hypertension-induced left ventricular remodeling (Group C) and in normal controls (Group A) (P < 0.05). Lastly, the difference in the measurement of LAESV between the two methods was greater in patients with hypertension-induced left ventricular remodeling (Group C) than that in the control group (Group A) (P < 0.05). The post-processing time of the 3DE-HM data was significantly shorter than that using the 3DE-manual method (P < 0.05). There was no significant variability in repeated measurements at different time points using the 3DE-HM method either between subjects in different groups or within the same subject. 3DE-HM is a quick and feasible method for left ventricular quantification and is clinically applicable for evaluating patients with left atrial and left ventricular remodeling.

  5. Multi-Ethnic Study of Atherosclerosis: Association between Left Atrial Function Using Tissue Tracking from Cine MR Imaging and Myocardial Fibrosis

    PubMed Central

    Imai, Masamichi; Ambale Venkatesh, Bharath; Samiei, Sanaz; Donekal, Sirisha; Habibi, Mohammadali; Armstrong, Anderson C.; Heckbert, Susan R.; Wu, Colin O.; Bluemke, David A.

    2014-01-01

    Purpose To investigate the association between left atrial (LAleft atrium) function and left ventricular myocardial fibrosis using cardiac magnetic resonance (MR) imaging in a multi-ethnic population. Materials and Methods For this HIPAA-compliant study, the institutional review board at each participating center approved the study protocol, and all participants provided informed consent. Of 2839 participants who had undergone cardiac MR in 2010–2012, 143 participants with myocardial scar determined with late gadolinium enhancement and 286 age-, sex-, and ethnicity-matched control participants were identified. LAleft atrium volume, strain, and strain rate were analyzed by using multimodality tissue tracking from cine MR imaging. T1 mapping was applied to assess diffuse myocardial fibrosis. The association between LAleft atrium parameters and myocardial fibrosis was evaluated with the Student t test and multivariable regression analysis. Results The scar group had significantly higher minimum LAleft atrium volume than the control group (mean, 22.0 ± 10.5 [standard deviation] vs 19.0 ± 7.8, P = .002) and lower LAleft atrium ejection fraction (45.9 ± 10.7 vs 51.3 ± 8.7, P < .001), maximal LAleft atrium strain (Smaxmaximum LA strain) (25.4 ± 10.7 vs 30.6 ± 10.6, P < .001) and maximum LAleft atrium strain rate (SRmaxmaximum LA strain rate) (1.08 ± 0.45 vs 1.29 ± 0.51, P < .001), and lower absolute LAleft atrium strain rate at early diastolic peak (SRELA strain rate at early diastolic peak) (−0.77 ± 0.42 vs −1.01 ± 0.48, P < .001) and LAleft atrium strain rate at atrial contraction peak (SRALA strain rate at atrial contraction peak) (−1.50 ± 0.62 vs −1.78 ± 0.69, P < .001) than the control group. T1 time 12 minutes after contrast material injection was significantly associated with Smaxmaximum LA strain (β coefficient = 0.043, P = .013), SRmaxmaximum LA strain rate (β coefficient = 0.0025, P = .001), SRELA strain rate at early diastolic peak (β coefficient = −0.0016, P = .027), and SRALA strain rate at atrial contraction peakLA strain rate at atrial contraction peak (β coefficient −0.0028, P = .01) in the regression model. T1 time 25 minutes after contrast material injection was significantly associated with SRmaxmaximum LA strain rate (β coefficient = 0.0019, P = .016) and SRALA strain rate at atrial contraction peak (β coefficient = −0.0022, P = .034). Conclusion Reduced LAleft atrium regional and global function are related to both replacement and diffuse myocardial fibrosis processes. Clinical trial registration no. NCT00005487 © RSNA, 2014 Online supplemental material is available for this article. PMID:25019562

  6. Loss of atrial contractility is primary cause of atrial dilatation during first days of atrial fibrillation.

    PubMed

    Schotten, Ulrich; de Haan, Sunniva; Neuberger, Hans-Ruprecht; Eijsbouts, Sabine; Blaauw, Yuri; Tieleman, Robert; Allessie, Maurits

    2004-11-01

    Atrial fibrillation (AF) induces a progressive dilatation of the atria which in turn might promote the arrhythmia. The mechanism of atrial dilatation during AF is not known. To test the hypothesis that loss of atrial contractile function is a primary cause of atrial dilatation during the first days of AF, eight goats were chronically instrumented with epicardial electrodes, a pressure transducer in the right atrium, and piezoelectric crystals to measure right atrial diameter. AF was induced with the use of repetitive burst pacing. Atrial contractility was assessed during sinus rhythm, atrial pacing (160-, 300-, and 400-ms cycle length), and electrically induced AF. The compliance of the fibrillating right atrium was measured during unloading the atria with diuretics and loading with 1 liter of saline. All measurements were repeated after 6, 12, and 24 h of AF and then once a day during the first 5 days of AF. Recovery of the observed changes after spontaneous cardioversion was also studied. After 5 days of AF, atrial contractility during sinus rhythm or slow atrial pacing was greatly reduced. During rapid pacing (160 ms) or AF, the amplitude of the atrial pressure waves had declined to 20% of control. The compliance of the fibrillating atria increased twofold, whereas the right atrial pressure was unchanged. As a result, the mean right atrial diameter increased by approximately 12%. All changes were reversible within 3 days of sinus rhythm. We conclude that atrial dilatation during the first days of AF is due to an increase in atrial compliance caused by loss of atrial contractility during AF. Atrial compliance and size are restored when atrial contractility recovers after cardioversion of AF.

  7. Effects of the Mueller maneuver on functional mitral regurgitation and implications for obstructive sleep apnea.

    PubMed

    Pressman, Gregg S; Orban, Marek; Leinveber, Pavel; Parekh, Kunal; Singh, Manmeet; Kara, Tomas; Somers, Virend K

    2015-06-01

    Obstructive sleep apnea is prevalent and adversely affects cardiovascular health. However, little is known of the acute effects of an obstructive apnea on cardiovascular physiology. We hypothesized that pre-existing functional mitral regurgitation (MR) would worsen during performance of a Mueller maneuver (MM) used to simulate an obstructive apnea; 15 subjects with an ejection fraction ≤35% and pre-existing functional MR were studied with Doppler echocardiography. The radius of the proximal flow convergence was used as a measure of mitral regurgitant flow. Measurements were made at baseline, during the MM, and post-MM. Areas of all 4 chambers were also measured at these time points, both in systole and diastole. Mean flow convergence radius for the group decreased significantly during the transition from the late-MM to post-MM (0.65 → 0.57 mm, p = 0.001), implying increased MR during the MM. In addition, in 3 subjects, duration of MR increased during the MM. Right atrial (RA) areas, both systolic and diastolic, increased during the maneuver, whereas RA fractional area change decreased, indicating reduced RA emptying. Left ventricular emptying decreased early in the maneuver, probably because of the increased afterload burden, and then recovered. In conclusion, high negative intrathoracic pressure produces changes that, repeated hundreds of times per night in patients with obstructive sleep apnea, have the potential to worsen heart failure and predispose affected subjects to atrial fibrillation. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Effects of the Mueller Maneuver on Functional Mitral Regurgitation and Implications for Obstructive Sleep Apnea

    PubMed Central

    Pressman, Gregg S.; Orban, Marek; Leinveber, Pavel; Parekh, Kunal; Singh, Manmeet; Kara, Tomas; Somers, Virend K.

    2016-01-01

    Obstructive sleep apnea (OSA) is prevalent and adversely impacts cardiovascular health. However, little is known of the acute effects of an obstructive apnea on cardiovascular physiology. We hypothesized that pre-existing functional mitral regurgitation (MR) would worsen during performance of a Mueller maneuver (MM) used to simulate an obstructive apnea. 15 subjects with an ejection fraction ≤35% and pre-existing functional MR were studied with Doppler echocardiography. The radius of the proximal flow convergence was used as a measure of mitral regurgitant flow. Measurements were made at baseline, during the MM, and post-MM. Areas of all 4 chambers were also measured at these time points, both in systole and diastole. Mean flow convergence radius for the group decreased significantly during the transition from the late-MM to post-MM (0.65 mm → 0.57 mm, p = 0.001), implying increased MR during the MM. In addition, in 3 subjects duration of MR increased during the MM. Right atrial (RA) areas, both systolic and diastolic, increased during the maneuver while RA fractional area change decreased, indicating reduced RA emptying. Left ventricular (LV) emptying decreased early in the maneuver, probably due to the increased afterload burden, and then recovered. In conclusion, high negative intrathoracic pressure produces changes which, repeated hundreds of times per night in OSA patients, have the potential to worsen heart failure and predispose affected individuals to atrial fibrillation. PMID:25846766

  9. NT-proBNP values in elderly heart failure patients with atrial fibrillation and diabetes.

    PubMed

    Sitar Taut, Adela Viviana; Pop, Dana; Zdrenghea, Dumitru Tudor

    2015-01-01

    To evaluate N-terminal pro-BNP-type natriuretic peptide (NT-proBNP) plasmatic levels in heart failure patients with/without atrial fibrillation (AFib) and with/without diabetes (DM). The study enrolled 120 patients with heart failure, age 71.26±9.14, 48.3% AFib and 30.8% with DM. The patients were divided into 4 groups according to the presence or absence of AFib and DM: group 1, 46 patients in sinus rhythm (SR) without DM; group 2, 16 patients in SR with DM; group 3, 37 patients with AFib and without DM; group 4, 21 patients with both AFib and DM. The patients in SR with DM displayed lower NT-proBNP levels than those with AFib without DM (1196.75±1183.11 vs 1940.59±963.665, p=0.02). We recorded no significant difference in comparison with the patients who had both AFib and DM (1196.75±1183.11 vs 1452.67±1257.94, p=NS). There was no significant difference between groups 3 and 4. Statistically significant correlations between ejection fraction, namely NYHA class and NT-proBNP levels were recorded only in the patients in SR-group 1 (r=-0.42, p<0.01) and group 2 (r=-0.66, p<0.01). Correlations between plasma NT-proBNP levels and ejection fraction, namely NYHA class, were evinced only in patients in SR. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Cardiac structure and function predicts functional decline in the oldest old.

    PubMed

    Leibowitz, David; Jacobs, Jeremy M; Lande-Stessman, Irit; Gilon, Dan; Stessman, Jochanan

    2018-02-01

    Background This study examined the association between cardiac structure and function and the deterioration in activities of daily living (ADLs) in an age-homogenous, community-dwelling population of patients born in 1920-1921 over a five-year follow-up period. Design Longitudinal cohort study. Methods Patients were recruited from the Jerusalem Longitudinal Cohort Study, which has followed an age-homogenous cohort of Jerusalem residents born in 1920-1921. Patients underwent home echocardiography and were followed up for five years. Dependence was defined as needing assistance with one or more basic ADL. Standard echocardiographic assessment of cardiac structure and function, including systolic and diastolic function, was performed. Reassessment of ADLs was performed at the five-year follow-up. Results A total of 459 patients were included in the study. Of these, 362 (79%) showed a deterioration in at least one ADL at follow-up. Patients with functional deterioration had a significantly higher left ventricular mass index and left atrial volume with a lower ejection fraction. There was no significant difference between the diastolic parameters the groups in examined. When the data were examined categorically, a significantly larger percentage of patients with functional decline had an abnormal left ventricular ejection fraction and left ventricular hypertrophy. The association between left ventricular mass index and functional decline remained significant in all multivariate models. Conclusions In this cohort of the oldest old, an elevated left ventricular mass index, higher left atrial volumes and systolic, but not diastolic dysfunction, were predictive of functional disability.

  11. Association of serum chemerin concentrations with the presence of atrial fibrillation.

    PubMed

    Zhang, Guowei; Xiao, Mochao; Zhang, Lili; Zhao, Yue; Yang, Qinghui

    2017-05-01

    Objective Chemerin, a newly discovered adipokine, is correlated with hypertension, diabetes and coronary heart disease. The aim of this study is to investigate the association of serum chemerin concentrations with the presence of atrial fibrillation. Methods Serum chemerin concentrations were determined in 256 patients with atrial fibrillation and 146 healthy subjects. Atrial fibrillation patients were then divided into paroxysmal, persistent and permanent atrial fibrillation. Results Serum chemerin concentrations were significantly higher in atrial fibrillation patients compared with healthy controls. In subgroup studies, patients with permanent atrial fibrillation had higher serum chemerin concentrations than those with persistent and paroxysmal atrial fibrillation. Furthermore, significant higher serum chemerin concentrations were observed in persistent atrial fibrillation patients compared with paroxysmal atrial fibrillation subjects. Serum chemerin concentrations were associated with the presence of atrial fibrillation after logistic regression analysis. Pearson correlation analysis revealed a positive relation of serum chemerin concentrations with body mass index, systolic blood pressure, diastolic blood pressure, triglycerides, low-density lipoprotein cholesterol, blood urea nitrogen, creatinine, C-reactive protein and left atrial diameter. Conclusion Serum chemerin concentrations are associated with the presence of atrial fibrillation and atrial remodelling.

  12. Influencing factors for early acute cerebrovascular accidents in patients with stroke history following off-pump coronary artery bypass grafting.

    PubMed

    Wang, Bin; Jia, Ming; Jia, Shijie; Wan, Jiuhe; Zhou, Xiao; Luo, Zhimin; Zhou, Ye; Zhang, Jianqun

    2014-06-01

    To analyse risk factors for early acute cerebrovascular accidents following off-pump coronary artery bypass grafting (OPCAB) in patients with stroke history, and to propose preventive measures to reduce the incidence of these events. A total of 468 patients with a history of stroke underwent OPCAB surgery in Beijing Anzhen Hospital of China from January 2010 to September 2012. They were retrospectively divided into two groups according to the occurrence of early acute cerebrovascular accidents within 48 hours following OPCAB. Multivariate logistic regression analysis was used to find risk or protective factors for early acute cerebrovascular accidents following the OPCAB. Fifty-two patients (11.1%) suffered from early acute cerebrovascular accidents in 468 patients, including 39 cases of cerebral infarction, two cases of cerebral haemorrhage, 11 cases of transient ischaemic attack (TIA). There were significant differences between the two groups in preoperative left ventricular ejection fraction ≤ 35%, severe bilateral carotid artery stenosis, poorly controlled hypertension, intraoperative application of Enclose® II proximal anastomotic device, postoperative acute myocardial infarction, atrial fibrillation, hypotension, ventilation time > 48h, ICU duration >48h and mortality. Multivariate logistic regression analysis showed that preoperative severe bilateral carotid stenosis (OR=6.378, 95%CI: 2.278-20.987) and preoperative left ventricular ejection fraction ≤ 35% (OR=2.737, 95%CI: 1.267-6.389), postoperative acute myocardial infarction (OR=3.644, 95%CI: 1.928-6.876), postoperative atrial fibrillation (OR=3.104, 95%CI:1.135∼8.016) and postoperative hypotension (OR=4.173, 95%CI: 1.836∼9.701) were independent risk factors for early acute cerebrovascular accidents in patients with a history of stroke following OPCAB procedures, while intraoperative application of Enclose® II proximal anastomotic device was protective factor (OR=0.556, 95%CI: 0.337-0.925). This study indicated that patients with severe bilateral carotid stenosis, the left ventricular ejection fraction ≤35%, the postoperative acute myocardial infarction, postoperative atrial fibrillation and postoperative hypotension were more likely to suffer from early acute cerebrovascular accidents when they received OPCAB. Application of Enclose® II proximal anastomotic device may decrease the incidence of early acute cerebrovascular accidents during OPCAB. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  13. Clinical evaluation of a thin bipolar pacing lead.

    PubMed

    Breivik, K; Danilovic, D; Ohm, O J; Guerola, M; Stertman, W A; Suntinger, A

    1997-03-01

    The main disadvantages of bipolar pacing leads have traditionally been related to their relative thickness and stiffness compared to unipolar leads. In a new "drawn filled tube" plus "coated wire" technology, each conductor strand is composed of MP35N tubing filled with silver core and coated with a thin ETFE polymer insulation material. This and parallel winding of single anode and cathode conductors into a single bifilar coil resulted in a bipolar lead (ThinLine, Intermedics) with a body diameter and flexibility similar to unipolar leads. The lead is tined, polyurethane, with the cathode and the anode made of iridium-oxide-coated titanium (IROX). The slotted 8-mm2 cathode tip is coated with polyethylene glycol, a blood soluble material. We present the clinical evaluation results from four pacemaker clinics, where 47 leads (23 atrial-J model 432-04 and 24 ventricular model 430-10) were implanted in 25 patients and followed for up to 2 years. The lead handling characteristics were found to be very satisfactory. Electrical parameters of the leads were measured at implant and noninvasively on postoperative days 1, 2, 21, 42, and months 3, 6, 12, and 24. Mean chronic pulse width thresholds at 2.5 V were 0.14 +/- 0.05 ms in the atrium and 0.10 +/- 0.02 ms in the ventricle, pacing impedances 443 +/- 104 omega and 520 +/- 241 omega, while median electrogram amplitudes were > or = 3.5 mV and > or = 7 mV, respectively. Pacing impedances and thresholds were found to be slightly but statistically significantly higher in unipolar than in bipolar configuration--the findings are explainable by the lead construction. One of 47 leads failed 3 weeks after implant; the conductors were short circuited due to an error during the manufacturing process. We conclude that the new lead thus far has demonstrated appropriate mechanical and electrical characteristics.

  14. The optimized V-V interval determined by interventricular conduction times versus invasive measurement by LVdP/dtMAX.

    PubMed

    van Gelder, Berry M; Meijer, Albert; Bracke, Frank A

    2008-09-01

    We compared the calculated optimal V-V interval derived from intracardiac electrograms (IEGM) with the optimized V-V interval determined by invasive measurement of LVdP/dt(MAX). Thirty-two patients with heart failure (six females, ages 68 +/- 7.8 years) had a CRT device implanted. After implantation of the atrial, right and a left ventricular lead, the optimal V-V interval was calculated using the QuickOpt formula (St. Jude Medical, Sylmar, CA, USA) applied to the respective IEGM recordings (V-V(IEGM)), and also determined by invasive measurement of LVdP/dt(MAX) (V-V(dP/dt)). The optimal V-V(IEGM) and V-V(dP/dt) intervals were 52.7 +/- 18 ms and 24.0 +/- 33 ms, respectively (P = 0.017), without correlation between the two. The baseline LVdP/dt(MAX) was 748 +/- 191 mmHg/s. The mean value of LVdP/dt(MAX) at invasive optimization was 947 +/- 198 mmHg/s, and at the calculated optimal V-V(IEGM) interval 920 +/- 191 mmHg/s (P < 0.0001). In spite of this significant difference, there was a good correlation between both methods (R = 0.991, P < 0.0001). However, a similarly good correlation existed between the maximum value of LVdP/dt(MAX) and LVdP/dt(MAX) at a fixed V-V interval of 0 ms (R = 0.993, P < 0.0001), or LVdP/dt(MAX) at a randomly selected V-V interval between 0 and +80 ms (R = 0.991, P < 0.0001). Optimizing the V-V interval with the IEGM method does not yield better hemodynamic results than simultaneous BiV pacing. Although a good correlation between LVdP/dt(MAX) determined with V-V(IEGM) and V-V(dP/dt) can be constructed, there is no correlation with the optimal settings of V-V interval in the individual patient.

  15. Left ventricular diastolic filling with an implantable ventricular assist device: beat to beat variability with overall improvement

    NASA Technical Reports Server (NTRS)

    Nakatani, S.; Thomas, J. D.; Vandervoort, P. M.; Zhou, J.; Greenberg, N. L.; Savage, R. M.; McCarthy, P. M.

    1997-01-01

    OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.

  16. Decreased Mortality With Beta-Blockers in Patients With Heart Failure and Coexisting Atrial Fibrillation: An AF-CHF Substudy.

    PubMed

    Cadrin-Tourigny, Julia; Shohoudi, Azadeh; Roy, Denis; Talajic, Mario; Tadros, Rafik; Mondésert, Blandine; Dyrda, Katia; Rivard, Léna; Andrade, Jason G; Macle, Laurent; Guerra, Peter G; Thibault, Bernard; Dubuc, Marc; Khairy, Paul

    2017-02-01

    The impact of beta-blockers on mortality and hospitalizations was assessed in the largest randomized trial of patients with both atrial fibrillation (AF) and heart failure with a reduced ejection fraction (HFrEF): the Atrial Fibrillation-Congestive Heart Failure trial. Although beta-blockers are the cornerstone of therapy for HFrEF, a recent patient-level meta-analysis cast doubt on their efficacy in patients with coexisting AF. From a total of 1,376 subjects randomized in the AF-CHF trial, those without beta-blockers at baseline were propensity matched to a maximum of 2 exposed patients. All absolute standardized differences after matching were ≤10%. Primary analyses respected the intention-to-treat principle. In on-treatment sensitivity analyses, beta-blocker status was modeled as a time-dependent covariate. Baseline characteristics were comparable among the matched cohorts (mean age 70 ± 11 years, 81% male, and mean left ventricular ejection fraction 27 ± 6%). During a median follow-up of 37 months, beta-blockers were associated with significantly lower all-cause mortality (hazard ratio [HR]: 0.721, 95% confidence interval [CI]: 0.549 to 0.945; p = 0.0180) but not hospitalizations (HR: 0.886; 95% CI: 0.715 to 1.100; p = 0.2232). Similar results were obtained in sensitivity analyses that modeled beta-blockers as a time-dependent variable (HR: 0.668 for all-cause mortality; 95% CI: 0.511 to 0.874; p = 0.0032; HR: 0.814 for hospitalizations; 95% CI: 0.653 to 1.014; p = 0.0658). There were no significant interactions between beta-blockers and patterns (i.e., persistent vs. paroxysmal) or burden of AF with respect to mortality or hospitalizations. In propensity-matched analyses, beta-blockers were associated with significantly lower mortality but not hospitalizations in patients with HFrEF and AF, irrespective of the pattern or burden of AF. These results support current evidence-based recommendations for beta-blockers in patients with HFrEF, whether or not they have associated AF. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Observation of the efficacy of radiofrequency catheter ablation on patients with different forms of atrial fibrillation.

    PubMed

    Zhao, R-C; Han, W; Han, J; Yu, J; Guo, J; Fu, J-L; Li, Z; Zhao, R-Z

    2016-10-01

    To study the efficacy and safety of radiofrequency catheter ablation (RFCA) in patients with different forms of atrial fibrillation. By retrospective analysis, we summarize 720 cases, where patients diagnosed with atrial fibrillation in our hospital were treated with RFCA from February 2010 to October 2014. Among the cases, 425 were diagnosed with paroxysmal atrial fibrillation and 295 with non-paroxysmal atrial fibrillation (including persistent atrial fibrillation and permanent atrial fibrillation). All patients were followed up until June 2015 to compare and analyze the differences in operation success rates, complications and recurrence rates. 395 cases (92.9%) of paroxysmal atrial fibrillation and 253 cases (85.8%) with non-paroxysmal atrial fibrillation were subject to surgery and followed up. The age of onset, disease course, underlying diseases, left atrial diameter and combined anti-arrhythmics of patients with paroxysmal atrial fibrillation were lower than those of patients with non-paroxysmal atrial fibrillation, and the differences were statistically significant (p < 0.05). The success rate of the first ablation was higher than that of non-paroxysmal atrial fibrillation. Procedure time, procedure method, complications and recurrence rate of patients with paroxysmal atrial fibrillation were lower than those of non-paroxysmal atrial fibrillation group, and the differences were statistically significant (p < 0.05). When we compared apoplexy and heart failure caused by atrial fibrillation in the two groups, the difference was not statistically significant (Apoplexy: p = 0.186; Heart failure: p = 0.170). The individual ablation success rate was higher for paroxysmal atrial fibrillation, and long-term follow-up showed that the occurrence of apoplexy and heart failure was not different from the non-paroxysmal atrial fibrillation group.

  18. Impact of left atrial volume reduction concomitant with atrial fibrillation surgery on left atrial geometry and mechanical function.

    PubMed

    Marui, Akira; Saji, Yoshiaki; Nishina, Takeshi; Tadamura, Eiji; Kanao, Shotaro; Shimamoto, Takeshi; Sasahashi, Nozomu; Ikeda, Tadashi; Komeda, Masashi

    2008-06-01

    Left atrial geometry and mechanical functions exert a profound effect on left ventricular filling and overall cardiovascular performance. We sought to investigate the perioperative factors that influence left atrial geometry and mechanical functions after the Maze procedure in patients with refractory atrial fibrillation and left atrial enlargement. Seventy-four patients with atrial fibrillation and left atrial enlargement (diameter > or = 60 mm) underwent the Maze procedure in association with mitral valve surgery. The maximum left atrial volume and left atrial mechanical functions (booster pump, reservoir, and conduit function [%]) were calculated from the left atrial volume-cardiac cycle curves obtained by magnetic resonance imaging. A stepwise multiple regression analysis was performed to determine the independent variables that influenced the postoperative left atrial geometry and function. The multivariate analysis showed that left atrial reduction surgery concomitant with the Maze procedure and the postoperative maintenance of sinus rhythm were predominant independent variables for postoperative left atrial geometry and mechanical functions. Among the 58 patients who recovered sinus rhythm, the postoperative left atrial geometry and function were compared between patients with (VR group) and without (control group) left atrial volume reduction. At a mean follow-up period of 13.8 months, sinus rhythm recovery rate was better (85% vs 68%, P < .05) in the VR group and maximum left atrial volume was less (116 +/- 25 mL vs 287 +/- 73 mL, P < .001) than in the control group. The maximum left atrial volume reduced with time only in the VR group (reverse remodeling). Postoperative booster pump and reservoir function in the VR group were better than in the control group (25% +/- 6% vs 11% +/- 4% and 34% +/- 7% vs 16% +/- 4%, respectively, P < .001), whereas the conduit function in the VR group was lower than in the control group, indicating that the improvement of the booster pump and reservoir function compensated for the conduit function to left ventricular filling. Left atrial reduction concomitant with the Maze procedure helped restore both contraction (booster pump) and compliance (reservoir) of the left atrium and facilitated left atrial reverse remolding. Left atrial volume reduction and postoperative maintenance of sinus rhythm may be desirable in patients with refractory AF and left atrial enlargement.

  19. Assessment of atrial electromechanical interval using echocardiography after catheter ablation in patients with persistent atrial fibrillation

    PubMed Central

    Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang

    2016-01-01

    Abstract We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients’ duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. PMID:27924066

  20. Changes in the mRNA levels of delayed rectifier potassium channels in human atrial fibrillation.

    PubMed

    Lai, L P; Su, M J; Lin, J L; Lin, F Y; Tsai, C H; Chen, Y S; Tseng, Y Z; Lien, W P; Huang, S K

    1999-01-01

    We measured mRNA levels of delayed rectifier potassium channels in human atrial tissue to investigate the mechanism of the shortening of the atrial effective refractory period and the loss of rate-adaptive shortening of the atrial effective refractory period in human atrial fibrillation. A total of 34 patients undergoing open heart surgery were included. Atrial tissue was obtained from the right atrial free wall, right atrial appendage, left atrial free wall and left atrial appendage, respectively. The mRNA amounts of KVLQT1 (IKs), minK (beta-subunit of IKs), HERG (IKr), and KV1.5 (IKur) were measured by reverse transcription-polymerase chain reaction and normalized to the mRNA amount of GAPDH. We found that the mRNA levels of KV1.5, HERG and KVLQT1 were all significantly decreased in patients with persistent atrial fibrillation for more than 3 months. In contrast, the mRNA level of minK was significantly increased in patients with persistent atrial fibrillation for more than 3 months. We further showed that these changes were independent of the underlying cardiac disease, atrial filling pressure, gender and age. We also found that there was no spatial dispersion of mRNA levels among the four atrial sampling sites. Because the decrease in potassium currents results in a prolonged action potential, the shortening of the atrial effective refractory period in atrial fibrillation should be attributed to other factors. However, the decrease in IKs might contribute, at least in part, to the loss of rate-adaptive shortening of the atrial refractory period.

  1. Surgery for atrial fibrillation.

    PubMed

    Viganò, M; Graffigna, A; Ressia, L; Minzioni, G; Pagani, F; Aiello, M; Gazzoli, F

    1996-01-01

    The mechanisms of atrial fibrillation arc multiple reentry circuits spinning around the atrial surface, and these baffle any attempt to direct surgical interruption. The purpose of this article is to report the surgical experience in the treatment of isolated and concomitant atrial fibrillation at the Cardiac Surgical Institute of the University of Pavia. In cases of atrial fibrillation secondary to mitral/valve disease, surgical isolation of the left atrium at the time of mitral valve surgery can prevent atrial fibrillation from involving the right atrium, which can exert its diastolic pump function on the right ventricle. Left atrial isolation was performed on 205 patients at the time of mitral valve surgery. Atrial partitioning ("maze operation") creates straight and blind atrial alleys so that non-recentry circuits can take place. Five patients underwent this procedure. In eight-cases of atrial fibrillation secondary to atrial septal defect, the adult patients with atrial septal defect and chronic or paroxysmal atrial fibrillation underwent surgical isolation of the right atrium associated which surgical correction of the defect, in order to let sinus rhythm govern the left atrium and the ventricles. "Lone" atrial fibrillation occurs in hearts with no detectable organic disease. Bi-atrial isolation with creation of an atrial septal internodal "corridor" was performed on 14 patients. In cases of atrial fibrillation secondary to mitral valve disease, left atrial isolation was performed on 205 patients at the time of mitral valve surgery with an overall sinus rhythm recovery of 44%. In the same period, sinus rhythm was recovered and persisted in only 19% of 252 patients who underwent mitral valve replacement along (P < 0.001). Sinus rhythm was less likely to recover in patients with right atriomegaly requiring tricuspid valve annuloplasty: 59% vs 84% (P < 0.001). Restoration of the right atrial function raised the cardiac index from 2.25 +/- 0.55 1/min per m2 during atrial fibrillation to 2.54 +/- 0.58 1/min per m2, with a mean percentage increase in cardiac index of 13.5% (P < 0.00018). Atrial partitioning ("maze operation") was performed on five patients with an immediate sinus rhythm recovery of 100%, but with two patients requiring pacemaker implant. Seven out of eight patients (87.5%), with atrial fibrillation secondary to atrial septal defect, who underwent surgical isolation of the right atrium at the time of surgery were free from atrial fibrillation and without medications. 2-52 months after operation. Thirteen of 14 patients with "lone" atrial fibrillation who underwent corridor procedure remained in sinus rhythm with a sinus rhythm recovery rate of 92%. Different surgical options can be chosen for different cases of atrial fibrillation, according to the underlying cardiac disease.

  2. Is the Preoperative Administration of Amiodarone or Metoprolol More Effective in Reducing Atrial Fibrillation: After Coronary Bypass Surgery?

    PubMed

    Onk, Oruc Alper; Erkut, Bilgehan

    2015-10-01

    This study examined the influence of preoperative administration of amiodarone and metoprolol in preventing postoperative atrial fibrillation (AF) after coronary artery bypass grafting (CABG) surgery.The study comprised 251 patients who underwent CABG surgery at our hospital between January 2012 and May 2014. The patients were randomly divided into 2 groups: amiodarone therapy group (n = 122 patients) and metoprolol therapy group (n = 129 patients).In the amiodarone group, the patients received amiodarone tablet orally 1 week before coronary bypass surgery and during the postoperative period. In the metoprolol group, the patients received metoprolol tablet orally 1 week before surgery and during the postoperative period. The AF development rate was retrospectively evaluated between the first 3 days and 4 weeks after surgery.AF developed in 14 patients in the amiodarone group and 16 patients in the metoprolol group 4 weeks after the operation (P = 0.612).No significant difference was observed between the groups in terms of intensive care unit and hospital stay. Furthermore, hospital charges were similar in both groups (P = 0.741).The results of the logistic regression analysis showed age, left ventricular ejection fraction, left atrial diameter, and aortic cross-clamping time to be predictors for postoperative AF.This study demonstrates that amiodarone and metoprolol have similar effects in prevention of AF after cardiac surgery. However, larger-scale studies need to be conducted to substantiate these findings.

  3. Towards modeling of cardiac micro-structure with catheter-based confocal microscopy: a novel approach for dye delivery and tissue characterization.

    PubMed

    Lasher, Richard A; Hitchcock, Robert W; Sachse, Frank B

    2009-08-01

    This work presents a methodology for modeling of cardiac tissue micro-structure. The approach is based on catheter-based confocal imaging systems, which are emerging as tools for diagnosis in various clinical disciplines. A limitation of these systems is that a fluorescent marker must be available in sufficient concentration in the imaged region. We introduce a novel method for the local delivery of fluorescent markers to cardiac tissue based on a hydro-gel carrier brought into contact with the tissue surface. The method was tested with living rabbit cardiac tissue and applied to acquire three-dimensional image stacks with a standard inverted confocal microscope and two-dimensional images with a catheter-based confocal microscope. We processed these image stacks to obtain spatial models and quantitative data on tissue microstructure. Volumes of atrial and ventricular myocytes were 4901 +/- 1713 and 10 299 +/-3598 mum (3) (mean+/-sd), respectively. Atrial and ventricular myocyte volume fractions were 72.4 +/-4.7% and 79.7 +/- 2.9% (mean +/-sd), respectively. Atrial and ventricular myocyte density was 165 571 +/- 55 836 and 86 957 +/- 32 280 cells/mm (3) (mean+/-sd), respectively. These statistical data and spatial descriptions of tissue microstructure provide important input for modeling studies of cardiac tissue function. We propose that the described methodology can also be used to characterize diseased tissue and allows for personalized modeling of cardiac tissue.

  4. Risk factors for persistent atrial fibrillation following successful hyperthyroidism treatment with radioiodine therapy.

    PubMed

    Zhou, Zhen-Hu; Ma, Long-Le; Wang, Le-Xin

    2011-01-01

    To investigate the predicting factors for persistent atrial fibrillation (AF) following radioiodine therapy for hyperthyroidism. Standard 12-lead ECG and 24-h Holter monitoring were performed in 94 patients (38 males, mean age 46.1±8.2 years) with persistent AF following radioiodine therapy for hyperthyroidism. Left ventricular (LV) function was assessed with two-dimensional echocardiography. Euthyroidism or hypothyroidism was achieved in 81% and 19% of the patients, respectively, after radioiodine therapy. At the end of follow-up (1.6±1.3 years), LV ejection fraction in the 52 patients with LV dysfunction was increased from 39.3±3.3% to 59.0±5.5% (p<0.01). In the 38 patients with pre-treatment paroxysmal AF, no AF was documented during the follow-up. In the 45 patients with pre-treatment persistent AF, AF was found in 27 (60%) during the follow-up. Multivariate logistic regression analysis showed that more than 55 years old in age (RR 2.76, 95% CI: 1.16-8.79, p<0.01), duration of hyperthyroidism (RR 3.08, 95% CI: 1.22-11.41, p<0.01) and duration of pre-treatment atrial fibrillation (RR 2.96, 95% CI: 1.31-7.68, p<0.01) were independent predictors for persistent AF following radioiodine therapy. Older age, duration of hyperthyroidism and pre-treatment duration of AF are risk factors for persistent AF following radioiodine therapy.

  5. [Atrial fibrillation as consequence and cause of structural changes of atria].

    PubMed

    Aparina, O P; Chikhireva, L N; Stukalova, O V; Mironova, N A; Kashtanova, S Iu; Ternovoĭ, S K; Golitsyn, S P

    2014-01-01

    Changes of atrial structure and function are the contributors of atrial fibrillation clinical course, complications and treatment effectiveness. Effects of inflammation and mechanical stretch on atrial structural remodeling leading to atrial fibrillation are reviewed in the article. Contemporary invasive and non-invasive methods of evaluation (including late gadolinium enhancement magnetic resonance imaging) of patients with atrial structural remodeling in atrial fibrillation are also described.

  6. Subclinical atrial fibrillation and the risk of stroke.

    PubMed

    Healey, Jeff S; Connolly, Stuart J; Gold, Michael R; Israel, Carsten W; Van Gelder, Isabelle C; Capucci, Alessandro; Lau, C P; Fain, Eric; Yang, Sean; Bailleul, Christophe; Morillo, Carlos A; Carlson, Mark; Themeles, Ellison; Kaufman, Elizabeth S; Hohnloser, Stefan H

    2012-01-12

    One quarter of strokes are of unknown cause, and subclinical atrial fibrillation may be a common etiologic factor. Pacemakers can detect subclinical episodes of rapid atrial rate, which correlate with electrocardiographically documented atrial fibrillation. We evaluated whether subclinical episodes of rapid atrial rate detected by implanted devices were associated with an increased risk of ischemic stroke in patients who did not have other evidence of atrial fibrillation. We enrolled 2580 patients, 65 years of age or older, with hypertension and no history of atrial fibrillation, in whom a pacemaker or defibrillator had recently been implanted. We monitored the patients for 3 months to detect subclinical atrial tachyarrhythmias (episodes of atrial rate >190 beats per minute for more than 6 minutes) and followed them for a mean of 2.5 years for the primary outcome of ischemic stroke or systemic embolism. Patients with pacemakers were randomly assigned to receive or not to receive continuous atrial overdrive pacing. By 3 months, subclinical atrial tachyarrhythmias detected by implanted devices had occurred in 261 patients (10.1%). Subclinical atrial tachyarrhythmias were associated with an increased risk of clinical atrial fibrillation (hazard ratio, 5.56; 95% confidence interval [CI], 3.78 to 8.17; P<0.001) and of ischemic stroke or systemic embolism (hazard ratio, 2.49; 95% CI, 1.28 to 4.85; P=0.007). Of 51 patients who had a primary outcome event, 11 had had subclinical atrial tachyarrhythmias detected by 3 months, and none had had clinical atrial fibrillation by 3 months. The population attributable risk of stroke or systemic embolism associated with subclinical atrial tachyarrhythmias was 13%. Subclinical atrial tachyarrhythmias remained predictive of the primary outcome after adjustment for predictors of stroke (hazard ratio, 2.50; 95% CI, 1.28 to 4.89; P=0.008). Continuous atrial overdrive pacing did not prevent atrial fibrillation. Subclinical atrial tachyarrhythmias, without clinical atrial fibrillation, occurred frequently in patients with pacemakers and were associated with a significantly increased risk of ischemic stroke or systemic embolism. (Funded by St. Jude Medical; ASSERT ClinicalTrials.gov number, NCT00256152.).

  7. Atrial Natriuretic Peptide Frameshift Mutation in Familial Atrial Fibrillation

    PubMed Central

    Hodgson-Zingman, Denice M.; Karst, Margaret L.; Zingman, Leonid V.; Heublein, Denise M.; Darbar, Dawood; Herron, Kathleen J.; Ballew, Jeffrey D.; de Andrade, Mariza; Burnett, John C.; Olson, Timothy M.

    2008-01-01

    Summary Atrial fibrillation is a common arrhythmia that is hereditary in a small subgroup of patients. In a family with 11 clinically affected members, we mapped an atrial fibrillation locus to chromosome 1p36-p35 and identified a heterozygous frameshift mutation in the gene encoding atrial natriuretic peptide. Circulating chimeric atrial natriuretic peptide (ANP) was detected in high concentration in subjects with the mutation, and shortened atrial action potentials were seen in an isolated heart model, creating a possible substrate for atrial fibrillation. This report implicates perturbation of the atrial natriuretic peptide–cyclic guanosine monophosphate (cGMP) pathway in cardiac electrical instability. PMID:18614783

  8. Atrial therapies reduce atrial arrhythmia burden in defibrillator patients.

    PubMed

    Friedman, P A; Dijkman, B; Warman, E N; Xia, H A; Mehra, R; Stanton, M S; Hammill, S C

    2001-08-28

    Approximately 25% of patients who receive an implantable cardioverter-defibrillator (ICD) to treat ventricular tachyarrhythmias have documented atrial tachyarrhythmias before implantation. This study assessed the ability of device-based prevention and termination therapies to reduce the burden of spontaneous atrial tachyarrhythmias. Patients with a standard indication for the implantation of an ICD and 2 episodes of atrial tachyarrhythmias in the preceding year received a dual-chamber ICD (Medtronic 7250 Jewel AF) that uses pacing and shock therapies for prevention and/or termination of atrial tachyarrhythmias. In a multicenter trial, patients were randomized to 3-month periods with atrial therapies "on" or "off" and subsequently crossed over. Analysis was performed on the 52 of 269 patients who had episodes of atrial tachyarrhythmia and had >/=30 days of follow-up with atrial therapies on and off. The atrial therapies resulted in a reduction of atrial tachyarrhythmia burden from a mean of 58.5 to 7.8 h/mo. A paired analysis (Wilcoxon signed-rank test) showed that the median difference in burden (1.1 h/mo) was highly significant (P=0.007). When the subgroup of 41 patients treated only with atrial pacing therapies was analyzed, the reduction in burden persisted (P=0.01). In this study, patients with a standard ICD indication and atrial tachyarrhythmias had a significant reduction in atrial tachyarrhythmia burden with use of atrial pacing and shock therapies.

  9. Antiarrhythmic properties of atrial pacing.

    PubMed

    Kliś, Magdalena; Sławuta, Agnieszka; Gajek, Jacek

    2017-01-01

    Bradycardia, atrial stretch and dilatation, autonomic nervous system disorders, and the presence of triggers such as atrial premature contractions, are factors which predispose a person to paroxysmal AF. Atrial pacing not only eliminates bradycardia but also prevents atrial premature contractions and dispersion of refractoriness, which are a substrate for atrial fibrillation. As the prolonged duration of atrial activation during pacing, especially from locations changing the physiological pattern of this activation (right atrium lateral wall, right atrium appendage), negatively influences both a mechanical and an electrical function of the atria, the atrial pacing site affects an atrial arrhythmogenesis. A conventional atrial lead location in the right atrium appendage causes non-physiological activation propagation, resulting in a prolongation of the activation time of both atria. This location is optimal according to a passive fixation of the atrial lead but the available contemporary active fixation leads could potentially be located in any area of the atrium. There is growing evidence of the benefit of pacing, imitating the physiological propagation of impulses within the atria. It seems that the Bachmann's bundle pacing is the best pacing site within the atria, not only positively influencing the atrial mechanical function but also best fulfilling the so-called atrial resynchronization function, in particular in patients with interatrial conduction delay. It can be effectively achieved using only one atrial electrode, and the slight shortening of atrioventricular conduction provides an additional benefit of this atrial pacing site.

  10. Presumptive partial atrial standstill secondary to atrial cardiomyopathy in a Greyhound.

    PubMed

    Wesselowski, S; Abbott, J; Borgarelli, M; Tursi, M

    2017-06-01

    Persistent atrial standstill is a rare arrhythmia in both human and veterinary patients. In recent decades, cases of partial atrial standstill have been recognized in humans. We describe a case of presumptive partial atrial standstill in a Greyhound, in which there was disparate left and right atrial electromechanical function and rapid progression to congestive heart failure over the span of fourteen weeks. An atrial cardiomyopathy characterized by severe, diffuse, fibrofatty replacement of the atrial myocardium was identified histologically. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Assessment of atrial electromechanical interval using echocardiography after catheter ablation in patients with persistent atrial fibrillation.

    PubMed

    Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang

    2016-11-01

    We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients' duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. © 2016 by the Journal of Biomedical Research. All rights reserved.

  12. Impaired Left Atrial Strain as a Predictor of New-onset Atrial Fibrillation After Aortic Valve Replacement Independently of Left Atrial Size.

    PubMed

    Pessoa-Amorim, Guilherme; Mancio, Jennifer; Vouga, Luís; Ribeiro, José; Gama, Vasco; Bettencourt, Nuno; Fontes-Carvalho, Ricardo

    2018-06-01

    Left atrial dysfunction in aortic stenosis may precede atrial enlargement and predict the occurrence of atrial fibrillation (AF). To test this hypothesis, we assessed left atrial function and determined its impact on the incidence of AF after aortic valve replacement. A total of 149 severe aortic stenosis patients (74±8.6 years, 51% men) with no prior AF were assessed using speckle-tracking echocardiography. Left atrial function was evaluated using peak atrial longitudinal strain (PALS), peak atrial contraction strain (PACS), and phasic left atrial volumes. The occurrence of AF was monitored in 114 patients from surgery until hospital discharge. In multiple linear regression, PALS and PACS were inversely correlated with left atrial dilation, left ventricular hypertrophy, and diastolic function. Atrial fibrillation occurred in 36 patients within a median time of 3 days [interquartile range, 1-4] after aortic valve replacement. In multiple Cox regression, PALS and PACS were independently associated with the incidence of AF (HR, 0.946; 95%CI, 0.910-0.983; P=.005 and HR, 0.932; 95%CI, 0.883-0.984; P=.011, respectively), even after further adjustment for left atrial dimensions. Both reduced PALS and PACS were associated with the incidence of AF in patients with nondilated left atria (P value for the interaction of PALS with left atrial dimensions=.013). In severe aortic stenosis, left atrial dysfunction predicted the incidence of postoperative AF independently of left atrial dilation, suggesting that speckle-tracking echocardiography before surgery may help in risk stratification, particularly in patients with nondilated left atria. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Atrial Arrhythmia in Ageing Spontaneously Hypertensive Rats: Unraveling the Substrate in Hypertension and Ageing

    PubMed Central

    Lau, Dennis H.; Shipp, Nicholas J.; Kelly, Darren J.; Thanigaimani, Shivshankar; Neo, Melissa; Kuklik, Pawel; Lim, Han S.; Zhang, Yuan; Drury, Karen; Wong, Christopher X.; Chia, Nicholas H.; Brooks, Anthony G.; Dimitri, Hany; Saint, David A.; Brown, Lindsay; Sanders, Prashanthan

    2013-01-01

    Background Both ageing and hypertension are known risk factors for atrial fibrillation (AF) although the pathophysiological contribution or interaction of the individual factors remains poorly understood. Here we aim to delineate the arrhythmogenic atrial substrate in mature spontaneously hypertensive rats (SHR). Methods SHR were studied at 12 and 15 months of age (n = 8 per group) together with equal numbers of age-matched normotensive Wistar-Kyoto control rats (WKY). Electrophysiologic study was performed on superfused isolated right and left atrial preparations using a custom built high-density multiple-electrode array to determine effective refractory periods (ERP), atrial conduction and atrial arrhythmia inducibility. Tissue specimens were harvested for structural analysis. Results Compared to WKY controls, the SHR demonstrated: Higher systolic blood pressure (p<0.0001), bi-atrial enlargement (p<0.05), bi-ventricular hypertrophy (p<0.05), lower atrial ERP (p = 0.008), increased atrial conduction heterogeneity (p = 0.001) and increased atrial interstitial fibrosis (p = 0.006) & CD68-positive macrophages infiltration (p<0.0001). These changes resulted in higher atrial arrhythmia inducibility (p = 0.01) and longer induced AF episodes (p = 0.02) in 15-month old SHR. Ageing contributed to incremental bi-atrial hypertrophy (p<0.01) and atrial conduction heterogeneity (p<0.01) without affecting atrial ERP, fibrosis and arrhythmia inducibility. The limited effect of ageing on the atrial substrate may be secondary to the reduction in CD68-positive macrophages. Conclusions Significant atrial electrical and structural remodeling is evident in the ageing spontaneously hypertensive rat atria. Concomitant hypertension appears to play a greater pathophysiological role than ageing despite their compounding effect on the atrial substrate. Inflammation is pathophysiologically linked to the pro-fibrotic changes in the hypertensive atria. PMID:24013508

  14. Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation.

    PubMed

    Cibis, Merih; Lindahl, Tomas L; Ebbers, Tino; Karlsson, Lars O; Carlhäll, Carl-Johan

    2017-01-01

    Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored. Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2-3 h (Time-1) and 4 weeks (Time-2) following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed. Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01); Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009); The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002) and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04) decreased; Thrombin-antithrombin complex (TAT) decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008). A significant correlation was found between TAT and the volume of stasis ( r 2 = 0.69, p < 0.001) at Time-1 and between TAT and the duration of stasis ( r 2 = 0.34, p = 0.04) at Time-2. Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation related atrial stunning.

  15. Stiff Left Atrial Syndrome: A Complication Undergoing Radiofrequency Catheter Ablation for Atrial Fibrillation.

    PubMed

    Yang, Yufan; Liu, Qiming; Wu, Zhihong; Li, Xuping; Xiao, Yichao; Tu, Tao; Zhou, Shenghua

    2016-07-01

    Radiofrequency catheter ablation for atrial fibrillation is an effective approach for treating atrial fibrillation. Its complications have attracted much attention, of which the stiff left atrial syndrome is a recently discovered complication that has not been completely understood. This study aims to investigate the concept, pathologic basis, clinical characteristics, predictors, and treatment protocols of the stiff left atrial syndrome after radiofrequency ablation for atrial fibrillation. © 2016 Wiley Periodicals, Inc.

  16. Flecainide-metoprolol combination reduces atrial fibrillation clinical recurrences and improves tolerability at 1-year follow-up in persistent symptomatic atrial fibrillation.

    PubMed

    Capucci, Alessandro; Piangerelli, Luca; Ricciotti, Jenny; Gabrielli, Domenico; Guerra, Federico

    2016-11-01

    Atrial fibrillation (AF) affects ∼2% of the total population. In order to prevent AF recurrences, many anti-arrhythmic drugs are currently available, but most of them are burdened by serious side effects and suboptimal efficacy. The aim of the present study was to test efficacy and safety of a combination of flecainide and metoprolol in preventing AF clinical recurrences. This study is a monocentric, prospective, randomized, open-blinded trial on 173 patients with a recent episode of paroxysmal or persistent AF. Patients were randomized into group A (flecainide + metoprolol; n = 80), group B (flecainide only; n = 72), or group C (metoprolol only; n = 21). Main exclusion criteria were recent acute coronary syndrome, heart failure New York Heart Association class III-IV, left ventricular ejection fraction <0.40, atrioventricular conduction disorders, and severe bradycardia. Primary endpoint was symptomatic recurrence over 1-year follow-up. Secondary endpoint was quality of life (QoL) over 1-year follow-up, as assessed by the SF-36 and Atrial Fibrillation Severity Scale questionnaires. Combination therapy with flecainide and metoprolol significantly reduced recurrences at 1-year follow-up when compared with flecainide alone in the whole population (66.7 vs. 46.8%; P < 0.001) and in patients with persistent AF (71.1 vs. 43.6%; P = 0.025) while adding beta-blocker therapy to paroxysmal AF showed no benefit over IC anti-arrhythmic drug-only. Patients randomized to combination therapy experienced a significant improvement of QoL when compared with those assigned to a flecainide-only regimen irrespective of AF type. Flecainide-metoprolol combination therapy improves effectiveness of rhythm control in persistent symptomatic AF and increases tolerability, with a concomitant reduction of side effects and a better compliance. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  17. Left atrial function measured by cardiac magnetic resonance imaging in patients with heart failure: clinical associations and prognostic value.

    PubMed

    Pellicori, Pierpaolo; Zhang, Jufen; Lukaschuk, Elena; Joseph, Anil C; Bourantas, Christos V; Loh, Huan; Bragadeesh, Thanjavur; Clark, Andrew L; Cleland, John G F

    2015-03-21

    Left atrial (LA) volume is an important marker of cardiac dysfunction and cardiovascular outcome in heart failure (HF), but LA function is rarely measured. Left atrial emptying function (LAEF), its clinical associations and prognostic value was studied in outpatients referred with suspected HF who were in sinus rhythm and had cardiac magnetic resonance imaging (CMRI). Heart failure was defined as relevant symptoms and signs with either a left ventricular ejection fraction (LVEF) <50% or amino-terminal pro-B-type natriuretic peptide (NTproBNP) >400 pg/mL (or >125 pg/mL if taking loop diuretics). Of 982 patients, 664 fulfilled the HF criteria and were in sinus rhythm. The median (interquartile range, IQR) LAEF was 42 (31-51)% and 55 (48-61)% in patients with and without HF (P < 0.001). Patients with HF in the lowest quartile of LAEF (23%; IQR: 17-28%) had lower LV and right ventricular (RV) EF, and greater LV and RV mass and higher plasma NTproBNP than those in the highest quartile of LAEF (56%; IQR: 53-61%). Log[LAEF] and log[NTproBNP] were inversely correlated (r = -0.410, P < 0.001). During a median follow-up of 883 (IQR: 469-1626) days, 394 (59%) patients with HF died or were admitted with HF and 101 (15%) developed atrial fibrillation (AF). In a multivariable Cox model, increasing LAEF, but not LVEF, was independently associated with survival (HR for 10% change: 0.81 (95%CI: 0.73-0.90), P = <0.001). Increasing age and decreasing LAEF predicted incident AF. In patients with HF, LAEF predicts adverse outcome independently of other measures of cardiac dysfunction. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  18. Catheter ablation versus medical therapy for patients with persistent atrial fibrillation: a systematic review and meta-analysis of evidence from randomized controlled trials.

    PubMed

    Chen, Chen; Zhou, Xinbin; Zhu, Min; Chen, Shenjie; Chen, Jie; Cai, Hongwen; Dai, Jin; Xu, Xiaoming; Mao, Wei

    2018-06-01

    The superiority of catheter ablation (CA) for persistent (and long-standing persistent) atrial fibrillation (AF) is currently not well defined. We performed a meta-analysis of randomized controlled trials (RCTs) to assess the clinical outcomes of CA compared with medical therapy in persistent AF patients. We systematically searched PubMed, EMBASE, the Cochrane Library, and clinicaltrials.gov for RCTs comparing CA with medical therapy in patients with persistent AF. For CA vs medical rhythm control, the primary outcome was freedom from atrial arrhythmia. For CA vs medical rate control, the primary outcome was the change in the left ventricular ejection fraction (LVEF). Eight studies with a total of 809 patients were included in the final analysis. Compared with medical rhythm control, CA was superior in achieving freedom from atrial arrhythmia (RR 2.08, 95% CI [1.67, 2.58]; P < 0.00001). Similar result was found in CA arm without antiarrhythmic drug use after operation (RR 1.82, 95%CI [1.33, 2.49]; P = 0.0002). CA was also superior in reducing the probability of cardioversion (RR 0.59, 95%CI [0.46, 0.76]; P < 0.0001) and hospitalization (RR 0.54, 95%CI [0.39, 0.74]; P = 0.0002). Compared with the medical rate control in persistent AF patients with heart failure (HF), CA significantly improved the LVEF (MD 7.72, 95%CI [4.78, 10.67]; P < 0.00001) and reduced Minnesota Living with Heart Failure Questionnaire scores (MD 11.1395% CI [2.52-19.75]; P = 0.01). CA appeared to be superior to medical therapy in persistent AF patients and might be considered as a first-line therapy for some persistent AF patients especially for those with HF.

  19. Short-Lasting Episodes of Torsade de Pointes in the Chronic Atrioventricular Block Dog Model Have a Focal Mechanism, While Longer-Lasting Episodes Are Maintained by Re-Entry.

    PubMed

    Vandersickel, Nele; Bossu, Alexandre; De Neve, Jan; Dunnink, Albert; Meijborg, Veronique M F; van der Heyden, Marcel A G; Beekman, Jet D M; De Bakker, Jacques M T; Vos, Marc A; Panfilov, Alexander V

    2017-12-26

    This study investigated the arrhythmogenic mechanisms responsible for torsade de pointes (TdP) in the chronic atrioventricular block dog model, known for its high susceptibility for TdP. The mechanism of TdP arrhythmias has been under debate for many years. Focal activity as well as re-entry have both been mentioned in the initiation and the perpetuation of TdP. In 5 TdP-sensitive chronic atrioventricular block dogs, 56 needle electrodes were evenly distributed transmurally to record 240 unipolar local electrograms simultaneously. Nonterminating (NT) episodes were defibrillated after 10 s. Software was developed to automatically detect activation times and to create 3-dimensional visualizations of the arrhythmia. For each episode of ectopic activity (ranging from 2 beats to NT episodes), a novel methodology was created to construct directed graphs of the wave propagation and detect re-entry loops by using an iterative depth-first-search algorithm. Depending on the TdP definition (number of consecutive ectopic beats), we analyzed 29 to 54 TdP: 29 were longer than 5 beats. In the total group, 9 were NT and 45 were self-terminating. Initiation and termination were always based on focal activity. Re-entry becomes more important in the longer-lasting episodes (>14 beats), whereas in all NT TdP, re-entry was the last active mechanism. During re-entry, excitation fronts were constantly present in the heart, while during focal TdP, there was always a silent interval between 2 consecutive waves (142 ms) during which excitation fronts were absent. Interbeat intervals were significantly smaller for re-entry episodes-220 versus 310 ms in focal. Electrograms recorded in particular areas during NT TdP episodes had significantly smaller amplitude (0.38) than during focal episodes (0.59). TdP can be driven by focal activity as well as by re-entry depending on the duration of the episode. NT episodes are always maintained by re-entry, which can be identified in local unipolar electrograms by shorter interbeat intervals and smaller deflection amplitude. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Baseline characteristics of patients with heart failure and preserved ejection fraction included in the Karolinska Rennes (KaRen) study.

    PubMed

    Donal, Erwan; Lund, Lars H; Oger, Emmanuel; Hage, Camilla; Persson, Hans; Reynaud, Amélie; Ennezat, Pierre-Vladimir; Bauer, Fabrice; Sportouch-Dukhan, Catherine; Drouet, Elodie; Daubert, Jean-Claude; Linde, Cecilia

    2014-02-01

    Karolinska Rennes (KaRen) is a prospective observational study to characterize heart failure patients with preserved ejection fraction (HFpEF) and to identify prognostic factors for long-term mortality and morbidity. To report characteristics and echocardiography at entry and after 4-8 weeks of follow-up. Patients were included following an acute heart failure presentation with B-type natriuretic peptide (BNP)>100 ng/L or N-terminal pro-BNP (NT-proBNP)>300 ng/L and left ventricular ejection fraction (LVEF)>45%. The mean ± SD age of 539 included patients was 77 ± 9 years and 56% were women. Patient history included hypertension (78%), atrial tachyarrhythmia (44%), prior heart failure (40%) and anemia (37%), but left bundle branch block was rare (3.8%). Median NT-proBNP was 2448 ng/L (n=438), and median BNP 429 ng/L (n=101). Overall, 101 patients did not return for the follow-up visit, including 13 patients who died (2.4%). Apart from older age (80 ± 9 vs. 76 ± 9 years; P=0.006), there were no significant differences in baseline characteristics between patients who did and did not return for follow-up. Mean LVEF was lower at entry than follow-up (56% vs. 62%; P<0.001). At follow-up, mean E/e' was 12.9 ± 6.1, left atrial volume index 49.4±17.8mL/m(2). Mean global left ventricular longitudinal strain was -14.6 ± 3.9%; LV mass index was 126.6 ± 36.2g/m(2). Patients in KaRen were old with slight female dominance and hypertension as the most prevalent etiological factor. LVEF was preserved, but with increased LV mass and depressed LV diastolic and longitudinal systolic functions. Few patients had signs of electrical dyssynchrony (ClinicalTrials.gov.- NCT00774709). Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Right-Sided Cardiac Dysfunction in Heart Failure With Preserved Ejection Fraction and Worsening Renal Function.

    PubMed

    Mukherjee, Monica; Sharma, Kavita; Madrazo, Jose A; Tedford, Ryan J; Russell, Stuart D; Hays, Allison G

    2017-07-15

    In urban populations, worsening renal function (WRF) is well established in patients hospitalized with acute decompensated heart failure with preserved ejection fraction (HFpEF). However, the mechanisms for development of WRF in the setting of acute HF in HFpEF are unclear. In the present study, we sought to characterize conventional echocardiographic measures of right ventricular (RV) chamber size and function to determine whether RV dysfunction and/or adverse RV remodeling is related to WRF in patients with HFpEF. Our study included 104 adult patients with HFpEF (EF ≥ 55%) with technically adequate 2-dimensional echocardiograms performed during their hospitalization for acute decompensated HF to determine echocardiographic predictors of WRF, defined as a serum creatinine (Cr) increase of ≥ 0.3 mg/dl within 72 hours of hospitalization. Thirty-eight of the 104 patients (36%) developed WRF (mean Cr increase = 0.9 ± 0.1 mg/dl) during the hospitalization (mean age ± SD of 64 ± 12 years, 27 women [71%], 29 black [76%]). There were no significant differences in LV medial E/e' ratio and RV systolic pressure by WRF status or in linear dimensions of RV and right atrial size. RV fractional area change, a measure of RV function, however, was significantly decreased in HFpEF patients with WRF compared with the no WRF group (p = 0.003), whereas RV free wall thickness (p = 0.001) was increased. In conclusion, linear and volumetric measures of dimensions of right atrial and RV chamber size did not distinguish HFpEF patients with and without WRF. However, in HFpEF patients with WRF during acute HF hospitalization, there was a significant decrease in RV function and a significant increase in RV free wall thickness compared with matched patients with no WRF. These findings suggest that adverse RV remodeling and RV dysfunction occur in HFpEF patients with WRF. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Management of Arrhythmias in Heart Failure

    PubMed Central

    Masarone, Daniele; Limongelli, Giuseppe; Rubino, Marta; Valente, Fabio; Vastarella, Rossella; Ammendola, Ernesto; Gravino, Rita; Verrengia, Marina; Salerno, Gemma; Pacileo, Giuseppe

    2017-01-01

    Heart failure patients are predisposed to develop arrhythmias. Supraventricular arrhythmias can exacerbate the heart failure symptoms by decreasing the effective cardiac output and their control require pharmacological, electrical, or catheter-based intervention. In the setting of atrial flutter or atrial fibrillation, anticoagulation becomes paramount to prevent systemic or cerebral embolism. Patients with heart failure are also prone to develop ventricular arrhythmias that can present a challenge to the managing clinician. The management strategy depends on the type of arrhythmia, the underlying structural heart disease, the severity of heart failure, and the range from optimization of heart failure therapy to catheter ablation. Patients with heart failure, irrespective of ejection fraction are at high risk for developing sudden cardiac death, however risk stratification is a clinical challenge and requires a multiparametric evaluation for identification of patients who should undergo implantation of a cardioverter defibrillator. Finally, patients with heart failure can also develop symptomatic bradycardia, caused by sinus node dysfunction or atrio-ventricular block. The treatment of bradycardia in these patients with pacing is usually straightforward but needs some specific issue. PMID:29367535

  3. Receptor binding sites for atrial natriuretic factor are expressed by brown adipose tissue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bacay, A.C.; Mantyh, C.R.; Vigna, S.R.

    1988-09-01

    To explore the possibility that atrial natriuretic factor (ANF) is involved in thermoregulation we used quantitative receptor autoradiography and homogenate receptor binding assays to identify ANF bindings sites in neonatal rat and sheep brown adipose tissue, respectively. Using quantitative receptor autoradiography were were able to localize high levels of specific binding sites for {sup 125}I-rat ANF in neonatal rat brown adipose tissue. Homogenate binding assays on sheep brown fat demonstrated that the radioligand was binding to the membrane fraction and that the specific binding was not due to a lipophilic interaction between {sup 125}I-rat ANF and brown fat. Specific bindingmore » of {sup 125}I-rat ANF to the membranes of brown fat cells was inhibited by unlabeled rat ANF with a Ki of 8.0 x 10(-9) M, but not by unrelated peptides. These studies demonstrate that brown fat cells express high levels of ANF receptor binding sites in neonatal rat and sheep and suggest that ANF may play a role in thermoregulation.« less

  4. Severe tricuspid regurgitation in the aged: atrial remodeling associated with long-standing atrial fibrillation.

    PubMed

    Yamasaki, Naohito; Kondo, Fumiaki; Kubo, Toru; Okawa, Makoto; Matsumura, Yoshihisa; Kitaoka, Hiroaki; Yabe, Toshikazu; Furuno, Takashi; Doi, Yoshinori

    2006-12-01

    Severe idiopathic tricuspid regurgitation (TR) occurs in the aged, but the mechanism of TR is unclear and there is little information on atrial abnormalities associated with this condition. This study retrospectively analyzed patients with severe functional TR presenting with common clinical features suggesting a distinct syndrome. Eleven patients with severe functional TR were identified by reviewing the records of 16,235 consecutive patients. All patients had undergone clinical evaluation including echocardiography, electrocardiography and laboratory data. The median age of patients with severe functional TR was 78 years. All had a long-standing history of atrial fibrillation (median duration, 23 years). Clinical features are characterized by severe functional TR due to annular dilation, markedly dilated right atrium, episodes of right-sided heart failure, absent or diminished fibrillation waves on electrocardiogram, bradycardia probably due to partial atrial standstill, and decreased atrial natriuretic peptide secretion. During long-term follow up, right atrial size progressively increased in association with worsening TR. Severe functional TR occurs with long-standing atrial fibrillation and causes right-sided heart failure. The TR is caused by tricuspid valve systolic coaptation loss due to tricuspid annular dilation associated with atrial dilation. This condition is associated with atrial abnormalities, such as atrial standstill and impaired atrial natriuretic peptide secretion. We propose that atrial remodeling associated with atrial fibrillation is central to the occurrence of the syndrome.

  5. Atrial Fibrillation: Diagnosis

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: Diagnosis Past Issues / Winter 2015 Table of Contents ... of your body's cells and organs. Read More "Atrial Fibrillation" Articles Atrial Fibrillation / Who Is at Risk for ...

  6. Arm and wrist surface potential mapping for wearable ECG rhythm recording devices: a pilot clinical study

    NASA Astrophysics Data System (ADS)

    Lynn, W. D.; Escalona, O. J.; McEneaney, D. J.

    2013-06-01

    This study addresses an important question in the development of a ECG device that enables long term monitoring of cardiac rhythm. This device would utilise edge sensor technologies for dry, non-irritant skin contact suitable for distal limb application and would be supported by embedded ECG denoising processes. Contemporary ECG databases including those provided by MIT-BIH and Physionet are focused on interpretation of cardiac disease and rhythm tracking. The data is recorded using chest leads as in standard clinical practise. For the development of a peripherally located heart rhythm monitor, such data would be of limited use. To provide a useful database adequate for the development of the above mentioned cardiac monitoring device a unipolar body surface potential map from the left arm and wrist was gathered in 37 volunteer patients and characterized in this study. For this, the reference electrode was placed at the wrist. Bipolar far-field electrogram leads were derived and analysed. Factors such as skin variability, 50Hz noise interference, electrode contact noise, motion artifacts and electromyographic noise, presented a challenge. The objective was quantify the signal-to-noise ratio (SNR) at the far-field locations. Preliminary results reveal that an electrogram indicative of the QRS complex can be recorded on the distal portion of the left arm when denoised using signal averaging techniques.

  7. In Vivo Evaluation and Proof of Radiofrequency Safety of a Novel Diagnostic MR-Electrophysiology Catheter

    PubMed Central

    Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias

    2013-01-01

    An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. PMID:21337409

  8. In vivo evaluation and proof of radiofrequency safety of a novel diagnostic MR-electrophysiology catheter.

    PubMed

    Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias

    2011-03-01

    An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. Copyright © 2010 Wiley-Liss, Inc.

  9. Electrocardiogram: his bundle potentials can be recorded noninvasively beat by beat on surface electrocardiogram.

    PubMed

    Wang, Gaopin; Liu, Renguang; Chang, Qinghua; Xu, Zhaolong; Zhang, Yingjie; Pan, Dianzhu

    2017-03-15

    The micro waveform of His bundle potential can't be recorded beat-to-beat on surface electrocardiogram yet. We have found that the micro-wavelets before QRS complex may be related to atrioventricular conduction system potentials. This study is to explore the possibility of His bundle potential can be noninvasively recorded on surface electrocardiogram. We randomized 65 patients undergoing radiofrequency catheter ablation of paroxysmal superventricular tachycardia (exclude overt Wolff-Parkinson-White syndrome) to receive "conventional electrocardiogram" and "new electrocardiogram" before the procedure. His bundle electrogram was collected during the procedure. Comparative analysis of PA s (PA interval recorded on surface electrocardiogram), AH s (AH interval recorded on surface electrocardiogram) and HV s (HV interval recorded on surface electrocardiogram) interval recorded on surface "new electrocardiogram" and PA, AH, HV interval recorded on His bundle electrogram was investigated. There was no difference (P > 0.05) between groups in HV s interval (49.63 ± 6.19 ms) and HV interval (49.35 ± 6.49 ms). Results of correlational analysis found that HV S interval was significantly positively associated with HV interval (r = 0.929; P < 0.01). His bundle potentials can be noninvasively recorded on surface electrocardiogram. Noninvasive His bundle potential tracing might represent a new method for locating the site of atrioventricular block and identifying the origin of a wide QRS complex.

  10. Excessive Premature Atrial Complexes and the Risk of Recurrent Stroke or Death in an Ischemic Stroke Population.

    PubMed

    Vinther, Kristina H; Tveskov, Claus; Möller, Sören; Auscher, Soren; Osmanagic, Armin; Egstrup, Kenneth

    2017-06-01

    Our aim was to investigate the association of premature atrial complexes and the risk of recurrent stroke or death in patients with ischemic stroke in sinus rhythm. In a prospective cohort study, we used 24-hour Holter recordings to evaluate premature atrial complexes in patients consecutively admitted with ischemic strokes. Excessive premature atrial complexes were defined as >14 premature atrial complexes per hour and 3 or more runs of premature atrial complexes per 24 hours. During follow-up, 48-hour Holter recordings were performed after 6 and 12 months. Among patients in sinus rhythm, the association of excessive premature atrial complexes and the primary end point of recurrent stroke or death were estimated in both crude and adjusted Cox proportional hazards models. We further evaluated excessive premature atrial complexes contra atrial fibrillation in relation to the primary end point. Of the 256 patients included, 89 had atrial fibrillation. Of the patients in sinus rhythm (n = 167), 31 had excessive premature atrial complexes. During a median follow-up of 32 months, 50 patients (30% of patients in sinus rhythm) had recurrent strokes (n = 20) or died (n = 30). In both crude and adjusted models, excessive premature atrial complexes were associated with the primary end point, but not with newly diagnosed atrial fibrillation. Compared with patients in atrial fibrillation, those with excessive premature atrial complexes had similarly high risks of the primary end point. In patients with ischemic stroke and sinus rhythm, excessive premature atrial complexes were associated with a higher risk of recurrent stroke or death. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  11. Prevalence of atrial arrhythmias in arrhythmogenic right ventricular dysplasia/cardiomyopathy.

    PubMed

    Camm, Christian F; James, Cynthia A; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; te Riele, Anneline S J M; Judge, Daniel P; Tandri, Harikrishna; Calkins, Hugh

    2013-11-01

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is an inherited cardiomyopathy, characterized by right ventricular dysfunction and ventricular arrhythmias. Limited information is available concerning atrial arrhythmias in ARVD/C. The purpose of this study was to characterize spontaneous atrial arrhythmias in a large registry population of ARVD/C patients. Patients (n = 248) from the Johns Hopkins ARVD/C registry who met the diagnostic criteria and had undertaken genotype analysis were included. Medical records of each were reviewed to ascertain incidence and characteristics of atrial arrhythmia episodes. Detailed demographic, phenotypic, and structural information was obtained from registry data. Thirty-five patients with ARVD/C (14%) experienced one or more types of atrial arrhythmia during median follow-up of 5.78 (interquartile range 8.52) years. Atrial fibrillation was the most common atrial arrhythmia, occurring in 80% of ARVD/C patients with atrial arrhythmias. Patients developed atrial arrhythmias at a mean age of 43.0 ± 14.0 years. Atrial arrhythmia patients obtained a total of 22 inappropriate implantable cardioverter-defibrillator shocks during follow-up. Older age at last follow-up (P <.001) and male gender (P = .044) were associated with atrial arrhythmia development. Patients with atrial arrhythmias had a higher occurrence of death (P = .028), heart failure (P <.001), and left atrial enlargement on echocardiography (P = .004). Atrial arrhythmias are common in ARVD/C and present at a younger age than in the general population. They are associated with male gender, increasing age, and left atrial enlargement. Atrial arrhythmias are clinically important as they are associated with inappropriate implantable cardioverter-defibrillator shocks and increased risk of both death and heart failure. © 2013 Heart Rhythm Society. All rights reserved.

  12. [Quantitative Measurements on the Blood Flow Fields of Left Atrial Appendage using Vector Flow Mapping in Patients with Nonvalvular Atrial Fibrillation].

    PubMed

    Cai, Yu-Yan; Wei, Xin; Zhang, Xiao-Ling; Liu, Gu-Yue; Li, Xi; Tang, Hong

    2018-01-01

    To quantify the hemodynamic characteristics of patients with nonvalvular atrial fibrillation. Twenty patients with paroxysmal atrial fibrillation and 15 patients with persistent atrial fibrillation enrolled in this study,while 12 patients with sinus rhythms served as controls. The hemodynamic characteristics of the patients in left atrial appendage were measured by transesophageal echocardiography (TEE) and vector flow mapping (VFM) using indicators such as vectors,vortex and energy loss (EL). ① Significant differences appeared between the patients with atrial fibrillation and the controls in heart rate,size of left atrium,size of left atrial appendage (LAA),and velocities of LAA filling and emptying. ② Regular vectors in LAA in early systole and late diastole were found in the patients with paroxysmal atrial fibrillation and the controls; whereas,irregular vectors with direction alternating were visualized in the whole cardiac cycle in the patients with persistent atrial fibrillation. ③ Small vortexes were observed at the opening of the left atrial appendage in late diastole in the patients with paroxysmal atrial fibrillation and the controls. ④ Peak EL values occurred in early systole and late diastole in the patients with paroxysmal atrial fibrillation and the controls. But the patients with persistent atrial fibrillation had increased EL values over the whole cardiac cycle. VFM can visualize and quantify the hemodynamics of LAA in patients with different heart rhythms. It may provide a new method for assessing atrial fibrillation. CopyrightCopyright© by Editorial Board of Journal of Sichuan University (Medical Science Edition).

  13. Factors related to outcome in heart failure with a preserved (or normal) left ventricular ejection fraction.

    PubMed

    Sanderson, John E

    2016-07-01

    Heart failure with a preserved ejection faction (HFpEF) is a growing and expensive cause of heart failure (HF) affecting particularly the elderly. It differs in substantial ways in addition to the normal left ventricular ejection fraction, from the more easily recognized form of heart failure with a reduced ejection fraction (HFrEF or 'systolic heart failure') and unlike HFrEF there have been little advances in treatment. In part, this relates to the complexity of the pathophysiology and identifying the correct targets. In HFpEF, there appears to be widespread stiffening of the vasculature and the myocardium affecting ventricular function (both systolic and diastolic), impeding ventricular suction, and thus early diastolic filling leading to breathlessness on exertion and later atrial failure and fibrillation. Left ventricular ejection fraction tends to gradually decline and some evolve into HFrEF. Most patients also have a mixture of several co-morbidities including hypertension, diabetes, obesity, poor renal function, lack of fitness, and often poor social conditions. Therefore, many factors may influence outcome in an individual patient. In this review, the epidemiology, possible causation, pathophysiology, the influence of co-morbidities and some of the many potential predictors of outcome will be considered.

  14. Criteria for determining the need for surgical treatment of tricuspid regurgitation during mitral valve replacement

    PubMed Central

    2012-01-01

    Background Tricuspid regurgitation (TR) is common in patients with mitral valve disease; however, there are no straightforward, rapidly determinably criteria available for deciding whether TR repair should be performed during mitral valve replacement. The aim of our retrospective study was to identify a simple and fast criterion for determining whether TR repair should be performed in patients undergoing mitral valve replacement. Methods We reviewed the records of patients who underwent mitral valve replacement with or without (control) TR repair (DeVega or Kay procedure) from January 2005 to December 2008. Preoperative and 2-year postoperative echocardiographic measurements included right ventricular and atrial diameter, interventricular septum size, TR severity, ejection fraction, and pulmonary artery pressure. Results A total of 89 patients were included (control, n = 50; DeVega, n = 27; Kay, n = 12). Demographic and clinical characteristics were similar between groups. Cardiac variables were similar between the DeVega and Kay groups. Right atrium and ventricular diameter and ejection fraction were significantly decreased postoperatively both in the control and operation (DeVega + Kay) group (P < 0.05). Pulmonary artery pressure was significantly decreased postoperatively in-operation groups (P < 0.05). Our findings indicate that surgical intervention for TR should be considered during mitral valve replacement if any of the following preoperative criteria are met: right atrial transverse diameter > 57 mm; right ventricular end-diastolic diameter > 55 mm; pulmonary artery pressure > 58 mmHg. Conclusions Our findings suggest echocardiography may be used as a rapid and simple means of determining which patients require TR repair during mitral valve replacement. PMID:22443513

  15. Sex Differences in the Biology and Pathology of the Aging Heart.

    PubMed

    Keller, Kaitlyn M; Howlett, Susan E

    2016-09-01

    The knowledge that advanced age is a major risk factor for cardiovascular disease (CVD) has stimulated interest in cardiac aging. Understanding how the heart remodels with age can help us appreciate why older individuals are more likely to acquire heart disease. Growing evidence in both humans and animals shows that the heart exhibits distinct structural and functional changes as a consequence of age. These changes occur even in the absence of overt cardiovascular disease and are often maladaptive. For example, atrial hypertrophy and fibrosis may increase susceptibility to atrial fibrillation in older adults. Age-dependent increases in left ventricular fibrosis, stiffness, and wall thickness promote diastolic dysfunction, predisposing to heart failure with preserved ejection fraction. The influence of age on the heart is evident at rest but is even more prominent during exercise. There is also evidence for sex-specific variation in age-associated remodelling. For instance, there is some evidence that the number of ventricular myocytes declines with age through apoptosis in men but not in women. This helps explain why older men are more likely than women to experience heart failure with reduced ejection fraction. Emerging evidence from preclinical studies suggests that frailty rather than chronological age promotes adverse cardiac remodelling. Mechanisms implicated in cardiac aging include impaired calcium handling, excessive activation of the ß-adrenergic and renin-angiotensin systems, and mitochondrial dysfunction. Further research into cardiac aging in both sexes is needed, because it may be possible to modify disease treatment if the substrate upon which the disease first develops is better understood. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Change of heart dimensions and function during pregnancy in goats.

    PubMed

    Szaluś-Jordanow, Olga; Czopowicz, Michał; Witkowski, Lucjan; Moroz, Agata; Mickiewicz, Marcin; Frymus, Tadeusz; Markowska-Daniel, Iwona; Bagnicka, Emilia; Kaba, Jarosław

    2018-03-08

    The study aimed to evaluate the effect of pregnancy on heart diameters and function in goats. Transthoracic echocardiography of 12 female dairy goats of two Polish regional breeds was performed. A Mindray M7 diagnostic ultrasound system with Phased Array transducer was used. Simultaneously, electrocardiography was recorded. All animals were examined four times - at mating season, at the end of the first trimester, at the end of the second trimester and just before kidding. Eleven measurements were taken each time: aortic and left atrial diameter (AoD and LAD), right and left ventricular internal diameter in diastole (RVIDd and LVIDd), left ventricular internal diameter in systole (LVIDs), inter-ventricular septum thickness in diastole and systole (IVSd and IVSd) and left ventricular posterior wall in diastole and systole (LVPWd and LVPWs), maximum left and right ventricular outflow tract velocity (RVOT Vmax and LVOT Vmax). Nine consecutive measurements were derived: the ratio of the left atrial diameter to the aortic diameter (AoD/LAD), left ventricular fractional shortening (FS%), left ventricular ejection fraction (EF%), maximum outflow tract pressure gradients (RVOT PGmax and LVOT PGmax), left ventricular end-diastolic volume (LVEDV) and left ventricular end-systolic volume (LVESV), stroke volume (SV) and cardiac output (CO). HR, LAD, LVPWs, IVSs increased significantly in the first trimester. AoD and RVIDd were significantly higher around parturition. LVIDd, FS%, EF%, SV and CO rose both in the first and third trimester. No measurement decreased during pregnancy. The study confirms that pregnancy causes changes in the heart size and functioning. Copyright © 2018. Published by Elsevier Ltd.

  17. Left ventricular ejection fraction and left atrium diameter related to new-onset atrial fibrillation following acute myocardial infarction: a systematic review and meta-analysis.

    PubMed

    Zeng, Rui-Xiang; Chen, Mao-Sheng; Lian, Bao-Tao; Liao, Peng-Da; Zhang, Min-Zhou

    2017-10-06

    New-onset atrial fibrillation (NOAF) occurs frequently in patients with acute myocardial infarction (AMI), and is associated with increased subsequent cardiovascular mortality. However, only a few studies directly evaluated the relationship of left ventricular ejection fraction (LVEF) or left atrium diameter (LAD) and NOAF following AMI. MEDLINE ® , EMBASE ® and the Cochrane Library were carried out to find studies until January 2017. Pooled mean difference (MD) and 95% confidence interval (CI) were calculated to evaluate the value of LVEF and LAD in the prediction of NOAF after AMI. We performed sensitivity analyses to explore the potential sources of heterogeneity. Statistical analyses were carried out using the Revman 5.3. We included 10 qualifying studies comprising a total of 708 patients with NOAF and 6785 controls. Overall, decreased LVEF and increased LAD levels had a significant positive association with NOAF in patients with AMI. The MD in the LVEF levels between the patients with and those without NOAF was -4.91 units (95% Cl: -5.70 to -4.12), test for overall effect z-score = 12.18 ( p < 0.00001, I 2 = 35%). Moreover, in a subgroup analysis, the MD for LAD and NOAF was 2.55 units (95% Cl: 1.91 to 3.19), test for overall effect z-score = 7.80 ( p < 0.00001, I 2 = 57%). Our meta-analysis demonstrated that both decreased LVEF and increased LAD levels were associated with greater risk of NOAF following AMI.

  18. Effect of Obesity on the Prognostic Impact of Atrial Fibrillation in Heart Failure With Preserved Ejection Fraction.

    PubMed

    Yagawa, Mayuko; Nagatomo, Yuji; Izumi, Yuki; Mahara, Keitaro; Tomoike, Hitonobu; Shiraishi, Yasuyuki; Kohno, Takashi; Mizuno, Atsushi; Goda, Ayumi; Kohsaka, Shun; Yoshikawa, Tsutomu

    2017-06-23

    Although obesity is associated with left ventricular hypertrophy, diastolic dysfunction, and occurrence of atrial fibrillation (AF), obese heart failure (HF) patients have a more favorable clinical outcome (obesity paradox). The clinical impact of AF on obese or lean HF patients has not been fully elucidated.Methods and Results:We analyzed 1,681 patients who were enrolled in the West Tokyo Heart Failure Registry (WET-HF Registry), a multicenter, prospective cohort registry from 2005 through 2014. We assigned them to 3 categories based on body mass index (BMI): low, BMI <18.5; medium, BMI ≥18.5 and <25; and high, BMI ≥25 (n=182/915/400). The clinical endpoint was all-cause death or readmission for acute decompensated HF. During 406 days of follow-up (IQR, 116-739 days), AF was associated with a higher risk of the endpoint in the HF with preserved ejection fraction (HFpEF) group (P<0.001, log-rank test), but not in the HF with reduced EF (HFrEF) group. AF was associated with a higher risk of the endpoint in low and medium BMI patients with HFpEF (P=0.016 and 0.009, respectively). On Multivariate Cox proportional hazards analysis, AF was an independent predictor of the endpoint in patients with BMI <25 from the HFpEF group (hazard ratio, 1.74; 95% CI: 1.21-2.54, P=0.003), but not in the other subgroups. AF had a negative impact on clinical outcome in non-obese patients with HFpEF.

  19. Spectral of electrocardiographic RR intervals to indicate atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Nuryani, Nuryani; Satrio Nugroho, Anto

    2017-11-01

    Atrial fibrillation is a serious heart diseases, which is associated on the risk of death, and thus an early detection of atrial fibrillation is necessary. We have investigated spectral pattern of electrocardiogram in relation to atrial fibrillation. The utilized feature of electrocardiogram is RR interval. RR interval is the time interval between a two-consecutive R peaks. A series of RR intervals in a time segment is converted to a signal with a frequency domain. The frequency components are investigated to find the components which significantly associate to atrial fibrillation. A segment is defined as atrial fibrillation or normal segments by considering a defined number of atrial fibrillation RR in the segment. Using clinical data of 23 patients with atrial fibrillation, we find that the frequency components could be used to indicate atrial fibrillation.

  20. Concealed Accessory Pathways with a Single Ventricular and Two Discrete Atrial Insertion Sites.

    PubMed

    Kipp, Ryan T; Abu Sham'a, Raed; Hiroyuki, Ito; Han, Frederick T; Refaat, Marwan; Hsu, Jonathan C; Field, Michael E; Kopp, Douglas E; Marcus, Gregory M; Scheinman, Melvin M; Hoffmayer, Kurt S

    2017-03-01

    Atrioventricular reciprocating tachycardia (AVRT) utilizing a concealed accessory pathway is common. It is well appreciated that some patients may have multiple accessory pathways with separate atrial and ventricular insertion sites. We present three cases of AVRT utilizing concealed pathways with evidence that each utilizing a single ventricular insertion and two discrete atrial insertion sites. In case one, two discrete atrial insertion sites were mapped in two separate procedures, and only during the second ablation was the Kent potential identified. Ablation of the Kent potential at this site remote from the two atrial insertion sites resulted in the termination of the retrograde conduction in both pathways. Case two presented with supraventricular tachycardia (SVT) with alternating eccentric atrial activation patterns without alteration in the tachycardia cycle length. The two distinct atrial insertion sites during orthodromic AVRT and ventricular pacing were targeted and each of the two atrial insertion sites were successfully mapped and ablated. In case three, retrograde decremental conduction utilizing both atrial insertion sites was identified prior to ablation. After mapping and ablation of the first discrete atrial insertion site, tachycardia persisted utilizing the second atrial insertion site. Only after ablation of the second atrial insertion site was SVT noninducible, and VA conduction was no longer present. Concealed retrograde accessory pathways with discrete atrial insertion sites may have a common ventricular insertion site. Identification and ablation of the ventricular insertion site or the separate discrete atrial insertion sites result in successful treatment. © 2017 Wiley Periodicals, Inc.

  1. Evaluating the Atrial Myopathy Underlying Atrial Fibrillation: Identifying the Arrhythmogenic and Thrombogenic Substrate

    PubMed Central

    Goldberger, Jeffrey J.; Arora, Rishi; Green, David; Greenland, Philip; Lee, Daniel C.; Lloyd-Jones, Donald M.; Markl, Michael; Ng, Jason; Shah, Sanjiv J.

    2015-01-01

    Atrial disease or myopathy forms the substrate for atrial fibrillation (AF) and underlies the potential for atrial thrombus formation and subsequent stroke. Current diagnostic approaches in patients with AF focus on identifying clinical predictors with evaluation of left atrial size by echocardiography serving as the sole measure specifically evaluating the atrium. Although the atrial substrate underlying AF is likely developing for years prior to the onset of AF, there is no current evaluation to identify the pre-clinical atrial myopathy. Atrial fibrosis is one component of the atrial substrate that has garnered recent attention based on newer MRI techniques that have been applied to visualize atrial fibrosis in humans with prognostic implications regarding success of treatment. Advanced ECG signal processing, echocardiographic techniques, and MRI imaging of fibrosis and flow provide up-to-date approaches to evaluate the atrial myopathy underlying AF. While thromboembolic risk is currently defined by clinical scores, their predictive value is mediocre. Evaluation of stasis via imaging and biomarkers associated with thrombogenesis may provide enhanced approaches to assess risk for stroke in patients with AF. Better delineation of the atrial myopathy that serves as the substrate for AF and thromboembolic complications might improve treatment outcomes. Furthermore, better delineation of the pathophysiologic mechanisms underlying the development of the atrial substrate for AF, particularly in its earlier stages, could help identify blood and imaging biomarkers that could be useful to assess risk for developing new onset AF and suggest specific pathways that could be targeted for prevention. PMID:26216085

  2. Role of atrial endothelial cells in the development of atrial fibrosis and fibrillation in response to pressure overload.

    PubMed

    Kume, Osamu; Teshima, Yasushi; Abe, Ichitaro; Ikebe, Yuki; Oniki, Takahiro; Kondo, Hidekazu; Saito, Shotaro; Fukui, Akira; Yufu, Kunio; Miura, Masahiro; Shimada, Tatsuo; Takahashi, Naohiko

    Monocyte chemoattractant protein-1 (MCP-1)-mediated inflammatory mechanisms have been shown to play a crucial role in atrial fibrosis induced by pressure overload. In the present study, we investigated whether left atrial endothelial cells would quickly respond structurally and functionally to pressure overload to trigger atrial fibrosis and fibrillation. Six-week-old male Sprague-Dawley rats underwent suprarenal abdominal aortic constriction (AAC) or a sham operation. By day 3 after surgery, macrophages were observed to infiltrate into the endocardium. The expression of MCP-1 and E-selectin in atrial endothelium and the expression of intercellular adhesion molecule-1, vascular cell adhesion molecule-1, and ED1 in left atrial tissue were enhanced. Atrial endothelial cells were irregularly hypertrophied with the disarrangement of lines of cells by scanning electron microscopy. Various-sized gap formations appeared along the border in atrial endothelial cells, and several macrophages were located just in the endothelial gap. Along with the development of heterogeneous interstitial fibrosis, interatrial conduction time was prolonged and the inducibility of atrial fibrillation by programmed extrastimuli was increased in the AAC rats compared to the sham-operated rats. Atrial endothelium responds rapidly to pressure overload by expressing adhesion molecules and MCP-1, which induce macrophage infiltration into the atrial tissues. These processes could be an initial step in the development of atrial remodeling for atrial fibrillation. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Pulmonary vein activity does not predict the outcome of catheter ablation for persistent atrial fibrillation: A long-term multicenter prospective study.

    PubMed

    Prabhu, Sandeep; Kalla, Manish; Peck, Kah Y; Voskoboinik, Aleksandr; McLellan, Alex J A; Pathik, Bupesh; Nalliah, Chrishan J; Wong, Geoff R; Sugumar, Hariharan; Azzopardi, Sonia M; Lee, Geoffrey; Ling, Liang-Han; Kalman, Jonathan M; Kistler, Peter M

    2018-03-02

    Pulmonary vein (PV) isolation (PVI) remains the cornerstone of catheter ablation (CA) in persistent atrial fibrillation (AF) (PeAF), although less successful than for paroxysmal AF. Whether rapid or fibrillatory (PV AF) PV firing may identify patients with PeAF more likely to benefit from a PV-based ablation approach is unclear. The purpose of this study was to determine the relationship between the PV cycle length (PVCL) and the PV AF outcome after CA. Before ablation, the multipolar catheter was placed in each PV and the left atrial appendage (LAA) for 100 consecutive cycles. The presence of PV AF, the average PVCL of all 4 veins (PV 4VAverage ), the fastest vein average (PV FVAverage ), the fastest cycle length (PV Fast ) both individually and relative to the average LAA cycle length were calculated. The ablation strategy included PVI and posterior wall isolation with a minimum of 12 months follow-up. A total of 123 patients underwent CA (age 62 ± 9.1 years; CHA 2 DS 2 -VASC score 1.6 ± 1.1; left ventricular ejection fraction 48% ± 13%; left atrial area 31 ± 8.7 cm 2 ; AF duration 16 ± 17 months). PVI was achieved in 100% of patients. Multiprocedure success (MPS; freedom from AF/atrial tachycardia episodes lasting >30 seconds) was achieved in 76% of patients at 24 ± 8.1 months of follow-up after 1.2 ± 0.4 procedures. PV activity was not associated with MPS either absolutely (PV 4VAverage [MPS no vs yes: 178 ± 27 ms vs 177 ± 24 ms; P = .92], PV FVAverage [P = .69], or PV Fast [P = .82]) or as a ratio relative to the LAA cycle length (PV 4VAverage /LAA 1.05 ± 0.11 vs 1.06 ± 0.21; P = .87). The presence of PV AF (31% vs 47%; P = .13) did not predict MPS. The rapidity of PV firing or presence of fibrillation within the PV was not predictive of outcome of CA for PeAF. PV activity does not identify patients most likely to benefit from a PV-based ablation strategy. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  4. Epicardial fat thickness correlates with P-wave duration, left atrial size and decreased left ventricular systolic function in morbid obesity.

    PubMed

    Fernandes-Cardoso, A; Santos-Furtado, M; Grindler, J; Ferreira, L A; Andrade, J L; Santo, M A

    2017-08-01

    Epicardial fat (EF) is increased in obesity and has important interactions with atrial and ventricular myocardium. Most of the evidence in this scenario can be confused by the presence of comorbidities such as hypertension, diabetes and dyslipidemia, which are very common in this population. The influence of EF on atrial remodeling and cardiac function demands further investigation on morbidly obese without these comorbidities. We prospectively recruited 20 metabolically healthy morbidly obese and 20 normo-weights controls. The maximum P-wave duration (PWD) was analyzed by 12-lead electrocardiogram. Left atrial diameter (LAD), left ventricular ejection fraction (LVEF) and EF thickness (EFT) were evaluated by two-dimensional echocardiography. The mean of maximum PWD and LAD were significantly larger in the obese group as compared to the control group: 109.55 ± 11.52 ms × 89.38 ± 11.19 ms and 36.12 ± 3.46 mm × 31.45 ± 2.64 mm, (p < 0.0001). The mean LVEF was lower in the obese group: 63.15 ± 4.25% × 66.17 ± 3.37% (p < 0.017). The mean EFT was higher in the obese group: 7.72 ± 1.60 mm × 3.10 ± 0.85 mm (p < 0.0001). A positive correlation was found between EFT and PWD (r = 0.70; p = 0.001) and LAD (r = 0.667; p = 0.001). An inverse correlation was found between EFT and LVEF (r = -0.523; p = 0.001). In a multiple multivariate regression analysis the EFT remains correlated with LAD and LVEF. In a select group of morbidly obese, the excess of EF had a significant impact on atrial remodeling and cardiac function. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  5. Mitochondrial apoptotic pathway activation in the atria of heart failure patients due to mitral and tricuspid regurgitation.

    PubMed

    Chang, Jen-Ping; Chen, Mien-Cheng; Liu, Wen-Hao; Lin, Yu-Sheng; Huang, Yao-Kuang; Pan, Kuo-Li; Ho, Wan-Chun; Fang, Chih-Yuan; Chen, Chien-Jen; Chen, Huang-Chung

    2015-08-01

    Apoptosis occurs in atrial cardiomyocytes in mitral and tricuspid valve disease. The purpose of this study was to examine the respective roles of the mitochondrial and tumor necrosis factor-α receptor associated death domain (TRADD)-mediated death receptor pathways for apoptosis in the atrial cardiomyocytes of heart failure patients due to severe mitral and moderate-to-severe tricuspid regurgitation. This study comprised eighteen patients (7 patients with persistent atrial fibrillation and 11 in sinus rhythm). Atrial appendage tissues were obtained during surgery. Three purchased normal human left atrial tissues served as normal controls. Moderately-to-severely myolytic cardiomyocytes comprised 59.7±22.1% of the cardiomyocytes in the right atria and 52.4±12.9% of the cardiomyocytes in the left atria of mitral and tricuspid regurgitation patients with atrial fibrillation group and comprised 58.4±24.8% of the cardiomyocytes in the right atria of mitral and tricuspid regurgitation patients with sinus rhythm. In contrast, no myolysis was observed in the normal human adult left atrial tissue samples. Immunohistochemical analysis showed expression of cleaved caspase-9, an effector of the mitochondrial pathways, in the majority of right atrial cardiomyocytes (87.3±10.0%) of mitral and tricuspid regurgitation patients with sinus rhythm, and right atrial cardiomyocytes (90.6±31.4%) and left atrial cardiomyocytes (70.7±22.0%) of mitral and tricuspid regurgitation patients with atrial fibrillation. In contrast, only 5.7% of cardiomyocytes of the normal left atrial tissues showed strongly positive expression of cleaved caspase-9. Of note, none of the atrial cardiomyocytes in right atrial tissue in sinus rhythm and in the fibrillating right and left atria of mitral and tricuspid regurgitation patients, and in the normal human adult left atrial tissue samples showed cleaved caspase-8 expression, which is a downstream effector of TRADD of the death receptor pathway. Immunoblotting of atrial extracts showed that there was enhanced expression of cytosolic cytochrome c, an effector of the mitochondrial pathways, but no expression of membrane TRADD and cytosolic caspase-8 in the right atrial tissue of mitral and tricuspid regurgitation patients with sinus rhythm, and right atrial and left atrial tissues of mitral and tricuspid regurgitation patients with atrial fibrillation. Taken together, this study showed that mitochondrial pathway for apoptosis was activated in the right atria in sinus rhythm and in the left and right atria in atrial fibrillation of heart failure patients due to mitral and tricuspid regurgitation, and this mitochondrial pathway activation may contribute to atrial contractile dysfunction and enlargement in this clinical setting. Copyright © 2015. Published by Elsevier Inc.

  6. Down-regulation of L-type calcium channel and sarcoplasmic reticular Ca(2+)-ATPase mRNA in human atrial fibrillation without significant change in the mRNA of ryanodine receptor, calsequestrin and phospholamban: an insight into the mechanism of atrial electrical remodeling.

    PubMed

    Lai, L P; Su, M J; Lin, J L; Lin, F Y; Tsai, C H; Chen, Y S; Huang, S K; Tseng, Y Z; Lien, W P

    1999-04-01

    We investigated the gene expression of calcium-handling genes including L-type calcium channel, sarcoplasmic reticular calcium adenosine triphosphatase (Ca(2+)-ATPase), ryanodine receptor, calsequestrin and phospholamban in human atrial fibrillation. Recent studies have demonstrated that atrial electrical remodeling in atrial fibrillation is associated with intracellular calcium overload. However, the changes of calcium-handling proteins remain unclear. A total of 34 patients undergoing open heart surgery were included. Atrial tissue was obtained from the right atrial free wall, right atrial appendage, left atrial free wall and left atrial appendage, respectively. The messenger ribonucleic acid (mRNA) amount of the genes was measured by reverse transcription-polymerase chain reaction and normalized to the mRNA levels of glyceraldehyde 3-phosphate dehydrogenase. The mRNA of L-type calcium channel and of Ca(2+)-ATPase was significantly decreased in patients with persistent atrial fibrillation for more than 3 months (0.36+/-0.26 vs. 0.90+/-0.88 for L-type calcium channel; 0.69+/-0.42 vs. 1.21+/-0.68 for Ca(2+)-ATPase; both p < 0.05, all data in arbitrary unit). We further demonstrated that there was no spatial dispersion of the gene expression among the four atrial tissue sampling sites. Age, gender and underlying cardiac disease had no significant effects on the gene expression. In contrast, the mRNA levels of ryanodine receptor, calsequestrin and phospholamban showed no significant change in atrial fibrillation. L-type calcium channel and the sarcoplasmic reticular Ca(2+)-ATPase gene were down-regulated in atrial fibrillation. These changes may be a consequence of, as well as a contributory factor for, atrial fibrillation.

  7. New-Onset Atrial Fibrillation in the Critically Ill*

    PubMed Central

    Moss, Travis J.; Calland, James Forrest; Enfield, Kyle B.; Gomez-Manjarres, Diana C.; Ruminski, Caroline; DiMarco, John P.; Lake, Douglas E.

    2017-01-01

    Objective: To determine the association of new-onset atrial fibrillation with outcomes, including ICU length of stay and survival. Design: Retrospective cohort of ICU admissions. We found atrial fibrillation using automated detection (≥ 90 s in 30 min) and classed as new-onset if there was no prior diagnosis of atrial fibrillation. We identified determinants of new-onset atrial fibrillation and, using propensity matching, characterized its impact on outcomes. Setting: Tertiary care academic center. Patients: A total of 8,356 consecutive adult admissions to either the medical or surgical/trauma/burn ICU with available continuous electrocardiogram data. Interventions: None. Measurements and Main Results: From 74 patient-years of every 15-minute observations, we detected atrial fibrillation in 1,610 admissions (19%), with median burden less than 2%. Most atrial fibrillation was paroxysmal; less than 2% of admissions were always in atrial fibrillation. New-onset atrial fibrillation was subclinical or went undocumented in 626, or 8% of all ICU admissions. Advanced age, acute respiratory failure, and sepsis were the strongest predictors of new-onset atrial fibrillation. In propensity-adjusted regression analyses, clinical new-onset atrial fibrillation was associated with increased hospital mortality (odds ratio, 1.63; 95% CI, 1.01–2.63) and longer length of stay (2.25 d; CI, 0.58–3.92). New-onset atrial fibrillation was not associated with survival after hospital discharge (hazard ratio, 0.99; 95% CI, 0.76–1.28 and hazard ratio, 1.11; 95% CI, 0.67–1.83, respectively, for subclinical and clinical new-onset atrial fibrillation). Conclusions: Automated analysis of continuous electrocardiogram heart rate dynamics detects new-onset atrial fibrillation in many ICU patients. Though often transient and frequently unrecognized, new-onset atrial fibrillation is associated with poor hospital outcomes. PMID:28296811

  8. Exploiting periodicity to extract the atrial activity in atrial arrhythmias

    NASA Astrophysics Data System (ADS)

    Llinares, Raul; Igual, Jorge

    2011-12-01

    Atrial fibrillation disorders are one of the main arrhythmias of the elderly. The atrial and ventricular activities are decoupled during an atrial fibrillation episode, and very rapid and irregular waves replace the usual atrial P-wave in a normal sinus rhythm electrocardiogram (ECG). The estimation of these wavelets is a must for clinical analysis. We propose a new approach to this problem focused on the quasiperiodicity of these wavelets. Atrial activity is characterized by a main atrial rhythm in the interval 3-12 Hz. It enables us to establish the problem as the separation of the original sources from the instantaneous linear combination of them recorded in the ECG or the extraction of only the atrial component exploiting the quasiperiodic feature of the atrial signal. This methodology implies the previous estimation of such main atrial period. We present two algorithms that separate and extract the atrial rhythm starting from a prior estimation of the main atrial frequency. The first one is an algebraic method based on the maximization of a cost function that measures the periodicity. The other one is an adaptive algorithm that exploits the decorrelation of the atrial and other signals diagonalizing the correlation matrices at multiple lags of the period of atrial activity. The algorithms are applied successfully to synthetic and real data. In simulated ECGs, the average correlation index obtained was 0.811 and 0.847, respectively. In real ECGs, the accuracy of the results was validated using spectral and temporal parameters. The average peak frequency and spectral concentration obtained were 5.550 and 5.554 Hz and 56.3 and 54.4%, respectively, and the kurtosis was 0.266 and 0.695. For validation purposes, we compared the proposed algorithms with established methods, obtaining better results for simulated and real registers.

  9. Atrial Fibrillation: When the heart is not in rhythm | NIH MedlinePlus the Magazine

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: When the heart is not in rhythm Past ... show, Deal With It . Photo: TBS/Deal Understanding Atrial Fibrillation Atrial fibrillation (AFib) is the most common type ...

  10. Prospective Observational Cohort Study of Fetal Atrial Flutter & Supraventricular Tachycardia

    ClinicalTrials.gov

    2017-12-15

    Atrial Flutter; Tachycardia, Supraventricular; Tachycardia, Atrial Ectopic; Tachycardia, Reciprocating; Tachycardia Atrial; Tachycardia, Atrioventricular Nodal Reentry; Tachycardia, Paroxysmal; Fetal Hydrops

  11. Novel ion channel targets in atrial fibrillation.

    PubMed

    Hancox, Jules C; James, Andrew F; Marrion, Neil V; Zhang, Henggui; Thomas, Dierk

    2016-08-01

    Atrial fibrillation (AF) is the most common arrhythmia in humans. It is progressive and the development of electrical and structural remodeling makes early intervention desirable. Existing antiarrhythmic pharmacological approaches are not always effective and can produce unwanted side effects. Additional atrial-selective antiarrhythmic strategies are therefore desirable. Evidence for three novel ion channel atrial-selective therapeutic targets is evaluated: atrial-selective fast sodium channel current (INa) inhibition; small conductance calcium-activated potassium (SK) channels; and two-pore (K2P) potassium channels. Data from animal models support atrial-ventricular differences in INa kinetics and also suggest atrial-ventricular differences in sodium channel β subunit expression. Further work is required to determine whether intrinsic atrial-ventricular differences in human INa exist or whether functional differences occur due to distinct atrial and ventricular action and resting potentials. SK and K2P channels (particularly K2P 3.1) offer potentially attractive atrial-selective targets. Work is needed to identify the underlying basis of SK current that contributes to (patho)physiological atrial repolarization and settings in which SK inhibition is anti- versus pro-arrhythmic. Although K2P3.1 appears to be a promising target with comparatively selective drugs for experimental use, a lack of selective pharmacology hinders evaluation of other K2P channels as potential atrial-selective targets.

  12. Laser Atrial Septostomy: An Engineering Problem

    NASA Astrophysics Data System (ADS)

    Ben-Shachar, Giora; Cohen, Mark H.; Riemenschneider, Thomas A.; Beder, Stanley D.

    1987-04-01

    The purpose of this study was to develop a reproducible method for atrial septostomy in live animals, which would be independent of both atrial septal thickness and left atrial size. Seven mongrel dogs monitored electrocardiographically were anesthetized and instrumented with systemic and pulmonary arterial lines. A modified Mullin's transseptal sheath was advanced under fluoroscopic control to interrogate the left atrium and atrial septum. A 400 micron regular quartz or a laser heated metallic tip fiber was passed through the sheath up to the atrial septum. Lasing of the atrial septum was done with an Argon laser at power output of 5 watts. In three dogs, an atrial septosomy catheter was passed to the left atrium through the laser atrial septostomy and balloon atrial septostomy was performed. The laser atrial septostomy measured 3 x 5 mm in diameter. This interatrial communication could be enlarged with a balloon septostomy to over one cm in diameter. Hemodynamic and electrocardiographic monitoring were stable during the procedure. Engineering problems included: 1) radioluscency of the laser fibers thus preventing fluoroscopic localization of the fiber course; and 2) the inability to increase lateral vaporization of the atrial septum. It is concluded that further changes in the lasing fibers need to be made before the method can be considered for clinical use.

  13. Randomized, double-blind trial of simultaneous right and left atrial epicardial pacing for prevention of post-open heart surgery atrial fibrillation.

    PubMed

    Daoud, E G; Dabir, R; Archambeau, M; Morady, F; Strickberger, S A

    2000-08-15

    The purpose of this study was to assess simultaneous right and left atrial pacing as prophylaxis for postoperative atrial fibrillation. In a double-blind, randomized fashion, 118 patients who underwent open heart surgery were assigned to right atrial pacing at 45 bpm (RA-AAI; n=39), right atrial triggered pacing at a rate of >/=85 bpm (RA-AAT; n=38), or simultaneous right and left atrial triggered pacing at a rate of >/=85 bpm (Bi-AAT; n=41). Holter monitoring was performed for 4. 8+/-1.4 days after surgery to assess for episodes of atrial fibrillation lasting >5 minutes. The prevalence of postoperative atrial fibrillation was significantly less in the patients randomized to biatrial AAT pacing when compared with the other 2 pacing regimens (P=0.02). An episode of atrial fibrillation occurred in 4 (10%) of 41 patients in the Bi-AAT group compared with 11 (28%) of 39 patients in the RA-AAI group (P=0.03 versus Bi-AAT) and 12 (32%) of 38 patients in the RA-AAT group (P=0.01 versus Bi-AAT). There was no difference in the occurrence of atrial fibrillation between the right atrial AAI and AAT groups (P=0.8). There was no significant difference among the 3 groups with regard to the number of postoperative hospital days (7.3+/-4.2 days), morbidity (5.1%), or mortality rate (2.5%). Simultaneous right and left atrial triggered pacing is well tolerated and significantly reduces the prevalence of post-open heart surgery atrial fibrillation.

  14. Effects of Persistent Atrial Fibrillation-Induced Electrical Remodeling on Atrial Electro-Mechanics - Insights from a 3D Model of the Human Atria.

    PubMed

    Adeniran, Ismail; MacIver, David H; Garratt, Clifford J; Ye, Jianqiao; Hancox, Jules C; Zhang, Henggui

    2015-01-01

    Atrial stunning, a loss of atrial mechanical contraction, can occur following a successful cardioversion. It is hypothesized that persistent atrial fibrillation-induced electrical remodeling (AFER) on atrial electrophysiology may be responsible for such impaired atrial mechanics. This simulation study aimed to investigate the effects of AFER on atrial electro-mechanics. A 3D electromechanical model of the human atria was developed to investigate the effects of AFER on atrial electro-mechanics. Simulations were carried out in 3 conditions for 4 states: (i) the control condition, representing the normal tissue (state 1) and the tissue 2-3 months after cardioversion (state 2) when the atrial tissue recovers its electrophysiological properties after completion of reverse electrophysiological remodelling; (ii) AFER-SR condition for AF-remodeled tissue with normal sinus rhythm (SR) (state 3); and (iii) AFER-AF condition for AF-remodeled tissue with re-entrant excitation waves (state 4). Our results indicate that at the cellular level, AFER (states 3 & 4) abbreviated action potentials and reduced the Ca2+ content in the sarcoplasmic reticulum, resulting in a reduced amplitude of the intracellular Ca2+ transient leading to decreased cell active force and cell shortening as compared to the control condition (states 1 & 2). Consequently at the whole organ level, atrial contraction in AFER-SR condition (state 3) was dramatically reduced. In the AFER-AF condition (state 4) atrial contraction was almost abolished. This study provides novel insights into understanding atrial electro-mechanics illustrating that AFER impairs atrial contraction due to reduced intracellular Ca2+ transients.

  15. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of pacing as part of device therapy for atrial arrhythmias.

  16. [Right atrial appendage thrombosis during atrial fibrillation: an element to look for].

    PubMed

    Barbati, Giovanni; De Domenico, Renato; Rossi, Stefania; Vecchiato, Elena; Zeppellini, Roberto

    2017-03-01

    Oral anticoagulant therapy (OAT) is a mainstay of atrial fibrillation (AF) pharmacological treatment. Left atrial appendage closure is a possible treatment, when feasible, in patients with intracerebral hemorrhage during OAT. We report a case of right atrial appendage thrombosis in a patient with chronic AF admitted for syncope due to diuretic-induced orthostatic hypotension. Two years previously, he had undergone left atrial appendage closure with the Amplatzer Cardiac Plug device because of intracerebral hemorrhage during OAT. After neurological consult, OAT was resumed with apixaban 5 mg twice daily, and transesophageal echocardiography performed two months later showed complete resolution of the right atrial appendage thrombosis. This particular case underlines the importance of searching for a possible right atrial appendage thrombosis in patients affected by AF, and suggests that left atrial appendage closure in AF patients not suitable for OAT does not fully eliminate the risk of thromboembolism.

  17. Simulation of Atrial Fibrosis Using Coupled Myocyte-Fibroblast Cellular and Human Atrial Models

    PubMed Central

    Gao, Yuan

    2017-01-01

    Atrial fibrosis is characterized by expansion of extracellular matrix and increase in the number of fibroblasts which has been associated with the development and maintenance of atrial arrhythmias. However, the mechanisms how the fibrosis contributes to atrial arrhythmia remain incompletely understood. In this study, we used a proposed fibroblast model coupled with the human atrial myocyte to investigate the effects of fibrosis on atrial excitability and repolarization at both cellular and macroscopic levels. The 12-lead electrocardiogram (ECG) was also simulated to explore the index of clinical diagnosis for fibrosis. The simulation results showed that the fibrosis can modify action potential morphology of human atrial myocyte, slow down wave propagation, and have rate adaptation, thus causing the atrial electrical heterogeneity. The fibrosis alone was sufficient to cause arrhythmia, induce reentry wave, and result in low amplitude and wide P waves at normal heart rate and significant prolonged and inverse P waves at high heart rate. All these symptoms aggravated when the level of fibrosis increased. Our simulations demonstrated that fibrosis is the substrate of atrial arrhythmia and thereby may be a potential target in the treatment of atrial arrhythmias. PMID:29441121

  18. Optimal pacing modes after cardiac transplantation: is synchronisation of recipient and donor atria beneficial?

    PubMed Central

    Parry, Gareth; Malbut, Katie; Dark, John H; Bexton, Rodney S

    1992-01-01

    Objective—To investigate the response of the transplanted heart to different pacing modes and to synchronisation of the recipient and donor atria in terms of cardiac output at rest. Design—Doppler derived cardiac output measurements at three pacing rates (90/min, 110/min and 130/min) in five pacing modes: right ventricular pacing, donor atrial pacing, recipient-donor synchronous pacing, donor atrial-ventricular sequential pacing, and synchronous recipient-donor atrial-ventricular sequential pacing. Patients—11 healthy cardiac transplant recipients with three pairs of epicardial leads inserted at transplantation. Results—Donor atrial pacing (+11% overall) and donor atrial-ventricular sequential pacing (+8% overall) were significantly better than right ventricular pacing (p < 0·001) at all pacing rates. Synchronised pacing of recipient and donor atrial segments did not confer additional benefit in either atrial or atrial-ventricular sequential modes of pacing in terms of cardiac output at rest at these fixed rates. Conclusions—Atrial pacing or atrial-ventricular sequential pacing appear to be appropriate modes in cardiac transplant recipients. Synchronisation of recipient and donor atrial segments in this study produced no additional benefit. Chronotropic competence in these patients may, however, result in improved exercise capacity and deserves further investigation. PMID:1389737

  19. Assessment of the physiologic contribution of right atrial function to total right heart function in patients with and without pulmonary arterial hypertension.

    PubMed

    Sivak, Joseph A; Raina, Amresh; Forfia, Paul R

    2016-09-01

    Total right heart function requires normal function of both the right ventricle and the right atrium. However, the degree to which right atrial (RA) function and right ventricular (RV) function each contribute to total right heart function has not been quantified. In this study, we aimed to quantify the contribution of RA function to total right heart function in a group of pulmonary arterial hypertension (PAH) patients compared to a cohort of normal controls without cardiovascular disease. The normal cohort comprised 35 subjects with normal clinical echocardiograms, while the PAH cohort included 37 patients, of whom 31 had echocardiograms before and after initiation of PAH-specific therapy. Total right heart function was measured via tricuspid annular plane excursion (TAPSE). TAPSE was broken down into two components, the excursion occurring during RA contraction (TAPSERA) and that occurring before RA contraction (TAPSERV). RA fractional area change (RA-FAC) was also compared between the two groups. In the PAH cohort, more than half of the total TAPSE occurred during atrial systole, compared to less than one-third in the normal cohort (51.0% vs. 32.1%; P < 0.0001). There was a significant correlation between RA-FAC and TAPSE in the PAH cohort but not in the normal cohort. TAPSE improved significantly in the posttreatment cohort (1.7 vs. 2.1 cm), but TAPSERA continued to account for about half of the total TAPSE after treatment. RA function accounts for a significantly greater proportion of total right heart function in patients with PAH than in normal subjects.

  20. Assessment of the physiologic contribution of right atrial function to total right heart function in patients with and without pulmonary arterial hypertension

    PubMed Central

    Sivak, Joseph A.; Raina, Amresh

    2016-01-01

    Abstract Total right heart function requires normal function of both the right ventricle and the right atrium. However, the degree to which right atrial (RA) function and right ventricular (RV) function each contribute to total right heart function has not been quantified. In this study, we aimed to quantify the contribution of RA function to total right heart function in a group of pulmonary arterial hypertension (PAH) patients compared to a cohort of normal controls without cardiovascular disease. The normal cohort comprised 35 subjects with normal clinical echocardiograms, while the PAH cohort included 37 patients, of whom 31 had echocardiograms before and after initiation of PAH-specific therapy. Total right heart function was measured via tricuspid annular plane excursion (TAPSE). TAPSE was broken down into two components, the excursion occurring during RA contraction (TAPSERA) and that occurring before RA contraction (TAPSERV). RA fractional area change (RA-FAC) was also compared between the two groups. In the PAH cohort, more than half of the total TAPSE occurred during atrial systole, compared to less than one-third in the normal cohort (51.0% vs. 32.1%; P < 0.0001). There was a significant correlation between RA-FAC and TAPSE in the PAH cohort but not in the normal cohort. TAPSE improved significantly in the posttreatment cohort (1.7 vs. 2.1 cm), but TAPSERA continued to account for about half of the total TAPSE after treatment. RA function accounts for a significantly greater proportion of total right heart function in patients with PAH than in normal subjects. PMID:27683609

  1. F 16915 prevents heart failure-induced atrial fibrillation: a promising new drug as upstream therapy.

    PubMed

    Le Grand, Bruno; Letienne, Robert; Dupont-Passelaigue, Elisabeth; Lantoine-Adam, Frédérique; Longo, Frédéric; David-Dufilho, Monique; Michael, Georghia; Nishida, Kunihiro; Catheline, Daniel; Legrand, Philippe; Hatem, Stéphane; Nattel, Stanley

    2014-07-01

    Atrial fibrillation (AF) is a common complication of heart failure. The aim of the present study was to investigate the effects of a new pure docosahexaenoic acid derivative called F 16915 in experimental models of heart failure-induced atria dysfunction. The atrial dysfunction-induced AF was investigated (1) in a dog model of tachypacing-induced congestive heart failure and (2) in a rat model of heart failure induced by occlusion of left descending coronary artery and 2 months reperfusion. F 16915 (5 g/day for 4 weeks) significantly reduced the mean duration of AF induced by burst pacing in the dog model (989 ± 111 s in the vehicle group to 79 ± 59 s with F 16915, P < 0.01). This dose of F 16915 also significantly reduced the incidence of sustained AF (5/5 dogs in the vehicle group versus 1/5 with F 16915, P < 0.05). In the rat model, the percentage of shortening fraction in the F 16915 group (100 mg/kg p.o. daily) was significantly restored after 2 months (32.6 ± 7.4 %, n = 9 vs 17.6 ± 3.4 %, n = 9 in the vehicle group, P < 0.01). F 16915 also reduced the de-phosphorylation of connexin43 from atria tissue. The present results show that treatment with F 16915 reduced the heart dilation, resynchronized the gap junction activity, and reduced the AF duration in models of heart failure. Thus, F 16915 constitutes a promising new drug as upstream therapy for the treatment of AF in patients with heart failure.

  2. Predictors of Severe Tricuspid Regurgitation in Patients with Permanent Pacemaker or Automatic Implantable Cardioverter-Defibrillator Leads

    PubMed Central

    Najib, Mohammad Q.; Vittala, Satya S.; Challa, Suresh; Raizada, Amol; Tondato, Fernando J.; Lee, Howard R.; Chaliki, Hari P.

    2013-01-01

    Patients with permanent pacemaker or automatic implantable cardioverter-defibrillator (AICD) leads have an increased prevalence of tricuspid regurgitation. However, the roles of cardiac rhythm and lead-placement duration in the development of severe tricuspid regurgitation are unclear. We reviewed echocardiographic data on 26 consecutive patients who had severe tricuspid regurgitation after permanent pacemaker or AICD placement; before treatment, they had no organic tricuspid valve disease, pulmonary hypertension, left ventricular dysfunction, or severe tricuspid regurgitation. We compared the results to those of 26 control subjects who had these same devices but no more than mild tricuspid regurgitation. The patients and control subjects were similar in age (mean, 81 ±6 vs 81 ±8 yr; P = 0.83), sex (male, 42% vs 46%; P = 0.78), and left ventricular ejection fraction (0.60 ±0.06 vs 0.58 ± 0.05; P = 0.4). The patients had a higher prevalence of atrial fibrillation (92% vs 65%; P=0.01) and longer median duration of pacemaker or AICD lead placement (49.5 vs 5 mo; P < 0.001). After adjusting for age, sex, and right ventricular systolic pressure by multivariate logistic regression analysis, we found that atrial fibrillation (odds ratio=6.4; P = 0.03) and duration of lead placement (odds ratio=1.5/yr; P = 0.001) were independently associated with severe tricuspid regurgitation. Out study shows that atrial fibrillation and longer durations of lead placement might increase the risk of severe tricuspid regurgitation in patients with permanent pacemakers or AICDs. PMID:24391312

  3. Left atrial strain: a new parameter for assessment of left ventricular filling pressure.

    PubMed

    Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio

    2016-01-01

    In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.

  4. Effect of percutaneous transvenous mitral commissurotomy on left atrial appendage function: an immediate and 6-month follow-up transesophageal Doppler study.

    PubMed

    Vijayvergiya, Rajesh; Sharma, Rajat; Shetty, Ranjan; Subramaniyan, Anand; Karna, Sunil; Chongtham, Dhanraj

    2011-11-01

    The left atrial appendage (LAA) is a common site of thrombus formation and is the source of systemic thromboembolism in patients with rheumatic mitral stenosis. LAA contractile dysfunction is a common finding in these patients. The aim of this study was to assess immediate and 6-month follow-up LAA function by transesophageal Doppler echocardiography in patients who underwent percutaneous transvenous mitral commissurotomy (PTMC). Forty-seven consecutive patients with symptomatic critical mitral stenosis who underwent PTMC were enrolled. All had underwent transthoracic and transesophageal echocardiography before, 24 hours after, and 6 months after PTMC. Pulse Doppler velocities of the LAA were measured, including peak early diastolic (E wave), peak late diastolic (A wave), and peak systolic (S wave). The corresponding tissue Doppler velocities of the LAA, including peak early diastolic (E(LAA)), peak late diastolic (A(LAA)), and peak systolic (S(LAA)), were also measured. LAA ejection fraction was measured using the modified Simpson's method. The mean age of the 47 enrolled patients was 31.7 ± 10.26 years. Thirty-eight patients were in sinus rhythm, and the remaining nine were in atrial fibrillation. PTMC was successful in all patients. The pulse Doppler velocities of the LAA at baseline, after PTMC, and at 6-month follow-up were as follows: for the E wave, 15.29 ± 2.26, 17.02 ± 2.25, and 17.97 ± 2.55 cm/sec, respectively (P < .001); for the A wave 22.45 ± 4.11, 24.19 ± 4.21, and 25.99 ± 4.51 cm/sec, respectively (P < .001); and for the S wave, 28.52 ± 4.37, 31.45 ± 5.37, and 33.06 ± 4.99 cm/sec, respectively (P < .001). The corresponding tissue Doppler velocities of LAA were as follows: for E(LAA), 4.65 ± 0.91, 5.28 ± 0.85, and 5.80 ± 0.84 cm/sec, respectively (P < .001); for A(LAA), 6.67 ± 1.12, 7.33 ± 1.17, and 7.88 ± 1.22 cm/sec, respectively (P < .001); and for S(LAA), 4.67 ± 1.12, 5.52 ± 1.18, 6.07 ± 1.11 cm/sec, respectively (P < .001). There was a nonsignificant increase in LAA ejection fraction (48.97 ± 8.14% vs 52.3 ± 13.76% vs 52.11 ± 16.3%, respectively, P = .052). On subgroup analysis between patients in sinus rhythm and those with atrial fibrillation, there was no significant difference for LAA ejection fraction and pulse and tissue Doppler velocities. Very good intraclass correlation of the LAA parameters was also observed for the reproducibility of the data. The present study shows contractile dysfunction of the LAA in patients with critical mitral stenosis, which significantly improved after PTMC, and a further improvement was observed at 6-month follow-up. Favorable 6-month improvements in LAA parameters suggest continuous structural remodeling of the LAA after PTMC, which is clinically attributed to the absence of thromboembolism. Although there was an improvement in LAA function, it was far below the normal range, suggesting a need for continuous long-term monitoring and management of thromboembolism in these patients. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  5. Recovery of atrial function after atrial compartment operation for chronic atrial fibrillation in mitral valve disease.

    PubMed

    Shyu, K G; Cheng, J J; Chen, J J; Lin, J L; Lin, F Y; Tseng, Y Z; Kuan, P; Lien, W P

    1994-08-01

    We prospectively studied the recovery of atrial function after atrial compartment operation and mitral valve surgery in patients with chronic atrial fibrillation caused by mitral valve disease. Chronic atrial fibrillation is the most common arrhythmia in mitral valve disease. This arrhythmia is associated with excessive morbidity and mortality. Mitral valve surgery alone rarely eliminates it. Twenty-two patients underwent mitral valve surgery and a new surgical method, atrial compartment operation. Doppler echocardiography was performed in all patients before operation and at 1 week and 2 and 6 months after operation in the successful cardioversion group. Peak early diastolic (E) and atrial (A) filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves were measured. Sinus rhythm was restored immediately after operation in 91% of patients and was maintained for > 1 week in 15 (68%) of 22 patients and > 6 months in 14 (64%) of 22. Eleven of 15 patients had left atrial paralysis (A/E integral ratio 0) at 1 week and 6 of 14 patients at 2 months. Nine of 15 patients had right atrial paralysis (A/E integral ratio 0) at 1 week and 1 of 14 patients at 2 months. Both left and right atrial contractile function (presence of an A wave on Doppler findings) was detected at 6 months in 14 patients. Mean (+/- SD) peak atrial filling velocity of the mitral valve was 15 +/- 26 cm/s at 1 week, 38 +/- 39 cm/s at 2 months and 93 +/- 32 cm/s at 6 months (p < 0.001). Mean peak atrial filling velocity of the tricuspid valve was 14 +/- 19 cm/s at 1 week, 33 +/- 19 cm/s at 2 months and 50 +/- 19 cm/s at 6 months (p < 0.001). Peak early diastolic and atrial filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves increased significantly from 1 week to 6 months. Chronic atrial fibrillation in mitral valve disease can often be eliminated by atrial compartment operation. No surgical mortality or significant complications were encountered. Both left and right atrial function, as manifested by Doppler findings, recover after compartment operation and improve over time. The mechanical function of the right atrium recovers earlier than that of the left.

  6. Clinical Features and Surgical Results of Right Atrial Myxoma.

    PubMed

    Li, Han; Guo, Hongwei; Xiong, Hui; Xu, Jianping; Wang, Wei; Hu, Shengshou

    2016-01-01

    We retrospectively analyzed 367 patients receiving surgical resection of cardiac myxomas in our center over six years, and analyzed the incidence and surgical results of 28 cases of right atrial myxomas. We also compared the age, gender, and attached sites between left atrial myxoma and right atrial myxoma. Between January 2007 and December 2012, 28 patients with right atrial myxomas underwent surgical resection. There were 16 males and 12 females. The mean age was 47.77 ± 13.20 years (range: 8.00-79.00 years). Associated cardiac lesions included moderate and severe tricuspid regurgitation in four, coronary atherosclerotic heart disease in five, and pulmonary embolism in one. Twenty-seven patients (96.43%) were followed from 26 to 94 months (mean 55.78 ± 21.10 months). There was no early death after operation. The incidence of right atrial myxomas among sporadic cardiac myxomas was 7.89%. One patient died of lung cancer 34 months after myxoma resection. Two patients underwent coronary artery stent implantation due to coronary atherosclerotic heart disease during the follow-up period. One patient underwent myxoma resection due to recurrence in the left atrium four years after the first operation. There was no significant difference in the age between left atrial myxoma and right atrial myxoma (p > 0.05). There was a significant difference in the gender between left atrial myxomas and right atrial myxomas (p < 0.05). The most common attached sites of left atrial myxomas and right atrial myxomas are the atrial septum. Surgical resection of the right atrial myxoma results in good clinical outcomes and a decreased incidence of recurrence. © 2015 Wiley Periodicals, Inc.

  7. Mid-Term Results of Surgical Treatment of Atrial Fibrillation in Valvular Heart Disease Assesed by Speckle Tracking Echocardiography

    PubMed Central

    Lorenzo, Natalia; Mendez, Irene; Taibo, Mikel; Martinis, Gianfranco; Badia, Sara; Reyes, Guillermo; Aguilar, Rio

    2018-01-01

    Background Atrial fibrillation frequently affects patients with valvular heart disease. Ablation of atrial fibrillation during valvular surgery is an alternative for restoring sinus rhythm. Objectives This study aimed to evaluate mid-term results of successful atrial fibrillation surgical ablation during valvular heart disease surgery, to explore left atrium post-ablation mechanics and to identify predictors of recurrence. Methods Fifty-three consecutive candidates were included. Eligibility criteria for ablation included persistent atrial fibrillation <10 years and left atrium diameter < 6.0 cm. Three months after surgery, echocardiogram, 24-hour Holter monitoring and electrocardiograms were performed in all candidates who maintained sinus rhythm (44 patients). Echo-study included left atrial deformation parameters (strain and strain rate), using 2-dimensional speckle-tracking echocardiography. Simultaneously, 30 healthy individuals (controls) were analyzed with the same protocol for left atrial performance. Significance was considered with a P value of < 0.05. Results After a mean follow up of 17 ± 2 months, 13 new post-operative cases of recurrent atrial fibrillation were identified. A total of 1,245 left atrial segments were analysed. Left atrium was severely dilated in the post-surgery group and, mechanical properties of left atrium did not recover after surgery when compared with normal values. Left atrial volume (≥ 64 mL/m2) was the only independent predictor of atrial fibrillation recurrence (p = 0.03). Conclusions Left atrial volume was larger in patients with atrial fibrillation recurrence and emerges as the main predictor of recurrences, thereby improving the selection of candidates for this therapy; however, no differences were found regarding myocardial deformation parameters. Despite electrical maintenance of sinus rhythm, left atrium mechanics did not recover after atrial fibrillation ablation performed during valvular heart disease surgery. PMID:29561964

  8. Effects of Persistent Atrial Fibrillation-Induced Electrical Remodeling on Atrial Electro-Mechanics – Insights from a 3D Model of the Human Atria

    PubMed Central

    Adeniran, Ismail; MacIver, David H.; Garratt, Clifford J.; Ye, Jianqiao; Hancox, Jules C.; Zhang, Henggui

    2015-01-01

    Aims Atrial stunning, a loss of atrial mechanical contraction, can occur following a successful cardioversion. It is hypothesized that persistent atrial fibrillation-induced electrical remodeling (AFER) on atrial electrophysiology may be responsible for such impaired atrial mechanics. This simulation study aimed to investigate the effects of AFER on atrial electro-mechanics. Methods and Results A 3D electromechanical model of the human atria was developed to investigate the effects of AFER on atrial electro-mechanics. Simulations were carried out in 3 conditions for 4 states: (i) the control condition, representing the normal tissue (state 1) and the tissue 2–3 months after cardioversion (state 2) when the atrial tissue recovers its electrophysiological properties after completion of reverse electrophysiological remodelling; (ii) AFER-SR condition for AF-remodeled tissue with normal sinus rhythm (SR) (state 3); and (iii) AFER-AF condition for AF-remodeled tissue with re-entrant excitation waves (state 4). Our results indicate that at the cellular level, AFER (states 3 & 4) abbreviated action potentials and reduced the Ca2+ content in the sarcoplasmic reticulum, resulting in a reduced amplitude of the intracellular Ca2+ transient leading to decreased cell active force and cell shortening as compared to the control condition (states 1 & 2). Consequently at the whole organ level, atrial contraction in AFER-SR condition (state 3) was dramatically reduced. In the AFER-AF condition (state 4) atrial contraction was almost abolished. Conclusions This study provides novel insights into understanding atrial electro-mechanics illustrating that AFER impairs atrial contraction due to reduced intracellular Ca2+ transients. PMID:26606047

  9. Effects of Prolonged Spaceflight on Atrial Size, Atrial Electrophysiology, and Risk of Atrial Fibrillation.

    PubMed

    Khine, Htet W; Steding-Ehrenborg, Katarina; Hastings, Jeffrey L; Kowal, Jamie; Daniels, James D; Page, Richard L; Goldberger, Jeffery J; Ng, Jason; Adams-Huet, Beverley; Bungo, Michael W; Levine, Benjamin D

    2018-05-01

    The prevalence of atrial fibrillation (AF) in active astronauts is ≈5%, similar to the general population but at a younger age. Risk factors for AF include left atrial enlargement, increased number of premature atrial complexes, and certain parameters on signal-averaged electrocardiography, such as P-wave duration, root mean square voltage for the terminal 20 ms of the signal-averaged P wave, and P-wave amplitude. We aimed to evaluate changes in atrial structure, supraventricular beats, and atrial electrophysiology to determine whether spaceflight could increase the risk of AF. Thirteen astronauts underwent cardiac magnetic resonance imaging to assess atrial structure and function before and after 6 months in space and high-resolution Holter monitoring for multiple 48-hour time periods before flight, during flight, and on landing day. Left atrial volume transiently increased after 6 months in space (12±18 mL; P =0.03) without changing atrial function. Right atrial size remained unchanged. No changes in supraventricular beats were noted. One astronaut had a large increase in supraventricular ectopic beats but none developed AF. Filtered P-wave duration did not change over time, but root mean square voltage for the terminal 20 ms decreased on all fight days except landing day. No changes in P-wave amplitude were seen in leads II or V 1 except landing day for lead V 1 . Six months of spaceflight may be sufficient to cause transient changes in left atrial structure and atrial electrophysiology that increase the risk of AF. However, there was no definite evidence of increased supraventricular arrhythmias and no identified episodes of AF. © 2018 American Heart Association, Inc.

  10. The effects of the Cox maze procedure on atrial function

    PubMed Central

    Voeller, Rochus K.; Zierer, Andreas; Lall, Shelly C.; Sakamoto, Shun–ichiro; Chang, Nai–Lun; Schuessler, Richard B.; Moon, Marc R.; Damiano, Ralph J.

    2010-01-01

    Objective The effects of the Cox maze procedure on atrial function remain poorly defined. The purpose of this study was to investigate the effects of a modified Cox maze procedure on left and right atrial function in a porcine model. Methods After cardiac magnetic resonance imaging, 6 pigs underwent pericardiotomy (sham group), and 6 pigs underwent a modified Cox maze procedure (maze group) with bipolar radiofrequency ablation. The maze group had preablation and immediate postablation left and right atrial pressure–volume relations measured with conductance catheters. All pigs survived for 30 days. Magnetic resonance imaging was then repeated for both groups, and conductance catheter measurements were repeated for the right atrium in the maze group. Results Both groups had significantly higher left atrial volumes postoperatively. Magnetic resonance imaging–derived reservoir and booster pump functional parameters were reduced postoperatively for both groups, but there was no difference in these parameters between the groups. The maze group had significantly higher reduction in the medial and lateral left atrial wall contraction postoperatively. There was no change in immediate left atrial elastance or in the early and 30-day right atrial elastance after the Cox maze procedure. Although the initial left atrial stiffness increased after ablation, right atrial diastolic stiffness did not change initially or at 30 days. Conclusions Performing a pericardiotomy alone had a significant effect on atrial function that can be quantified by means of magnetic resonance imaging. The effects of the Cox maze procedure on left atrial function could only be detected by analyzing segmental wall motion. Understanding the precise physiologic effects of the Cox maze procedure on atrial function will help in developing less-damaging lesion sets for the surgical treatment of atrial fibrillation. PMID:19026812

  11. Murine Models of Heart Failure with Preserved Ejection Fraction: a “Fishing Expedition”

    PubMed Central

    Valero-Muñoz, Maria; Backman, Warren; Sam, Flora

    2017-01-01

    Summary Heart failure with preserved ejection fraction (HFpEF) is characterized by signs and symptoms of HF in the presence of a normal left ventricular (LV) ejection fraction (EF). Despite accounting for up to 50% of all clinical presentations of HF, the mechanisms implicated in HFpEF are poorly understood, thus precluding effective therapy. The pathophysiological heterogeneity in the HFpEF phenotype also contributes to this disease and likely to the absence of evidence-based therapies. Limited access to human samples and imperfect animal models that completely recapitulate the human HFpEF phenotype have impeded our understanding of the mechanistic underpinnings that exist in this disease. Aging and comorbidities such as atrial fibrillation, hypertension, diabetes and obesity, pulmonary hypertension and renal dysfunction are highly associated with HFpEF. Yet, the relationship and contribution between them remains ill-defined. This review discusses some of the distinctive clinical features of HFpEF in association with these comorbidities and highlights the advantages and disadvantage of commonly used murine models, used to study the HFpEF phenotype. PMID:29333506

  12. Association of Burden of Atrial Fibrillation With Risk of Ischemic Stroke in Adults With Paroxysmal Atrial Fibrillation: The KP-RHYTHM Study.

    PubMed

    Go, Alan S; Reynolds, Kristi; Yang, Jingrong; Gupta, Nigel; Lenane, Judith; Sung, Sue Hee; Harrison, Teresa N; Liu, Taylor I; Solomon, Matthew D

    2018-05-16

    Atrial fibrillation is a potent risk factor for stroke, but whether the burden of atrial fibrillation in patients with paroxysmal atrial fibrillation independently influences the risk of thromboembolism remains controversial. To determine if the burden of atrial fibrillation characterized using noninvasive, continuous ambulatory monitoring is associated with the risk of ischemic stroke or arterial thromboembolism in adults with paroxysmal atrial fibrillation. This retrospective cohort study conducted from October 2011 and October 2016 at 2 large integrated health care delivery systems used an extended continuous cardiac monitoring system to identify adults who were found to have paroxysmal atrial fibrillation on 14-day continuous ambulatory electrocardiographic monitoring. The burden of atrial fibrillation was defined as the percentage of analyzable wear time in atrial fibrillation or flutter during the up to 14-day monitoring period. Ischemic stroke and other arterial thromboembolic events occurring while patients were not taking anticoagulation were identified through November 2016 using electronic medical records and were validated by manual review. We evaluated the association of the burden of atrial fibrillation with thromboembolism while not taking anticoagulation after adjusting for the Anticoagulation and Risk Factors in Atrial Fibrillation (ATRIA) or CHA2DS2-VASc stroke risk scores. Among 1965 adults with paroxysmal atrial fibrillation, the mean (SD) age was 69 (11.8) years, 880 (45%) were women, 496 (25%) were persons of color, the median ATRIA stroke risk score was 4 (interquartile range [IQR], 2-7), and the median CHA2DS2-VASc score was 3 (IQR, 1-4). The median burden of atrial fibrillation was 4.4% (IQR ,1.1%-17.23%). Patients with a higher burden of atrial fibrillation were less likely to be women or of Hispanic ethnicity, but had more prior cardioversion attempts compared with those who had a lower burden. After adjusting for either ATRIA or CHA2DS2-VASc stroke risk scores, the highest tertile of atrial fibrillation burden (≥11.4%) was associated with a more than 3-fold higher adjusted rate of thromboembolism while not taking anticoagulants (adjusted hazard ratios, 3.13 [95% CI, 1.50-6.56] and 3.16 [95% CI, 1.51-6.62], respectively) compared with the combined lower 2 tertiles of atrial fibrillation burden. Results were consistent across demographic and clinical subgroups. A greater burden of atrial fibrillation is associated with a higher risk of ischemic stroke independent of known stroke risk factors in adults with paroxysmal atrial fibrillation.

  13. [Left versus bi-atrial radiofrequency ablation in the treatment of atrial fibrillation].

    PubMed

    Wang, Jian-Gang; Meng, Xu; Li, Hui

    2008-11-25

    To evaluate the effectiveness of radiofrequency modified maze operation for the treatment of atrial fibrillation (AF) and compare the results of the left versus bi-atrial procedures. 305 patients of organic heart disease combined with AF, 117 males and 188 females, aged (53 +/- 10), that underwent cardiac valve operation (n = 293) and/or coronary artery bypass graft surgery (n = 14), received concomitant atrial fibrillation, bi-atrial (n = 160) or left atrial (n = 145) with a mean duration of (36 +/- 43) months. Follow-up was conducted for (28 +/- 5) (3 - 42) months. Thirteen patients (4.3%) died postoperatively: 7 died of multisystem and organ failure, 3 of low cardiac output, 1 of rupture of left ventricle, 1 of arrhythmia, and 1 of sudden death. During the follow-up, 1 patient died of heart failure, 1 of encephalorrhagia and 1 of unknown reason in the bi-atrial group. At the end of the procedure 223 patients (73.1%) had sinus rhythm, with a sinus rhythm rate of 66.9% (107/160) in the bi-atrial group, significant lower than that in the left atrial group (80.0%, 116/145, P < 0.05). At late follow-up, 215 of the 266 patients (80.8%) were in stable sinus rhythm. Sinus rhythm rate of the bi-atrial group was 80.0%, not significantly different from that of the left atrial group (81.9%, P > 0.05). The Kaplan-Meier survival analysis showed there was no significant difference in the AF rhythm rate between these 2 groups (P = 0.33). Logistic regression analysis showed that the left atrial diameter of >/= 80 mm was an independent predictor of AF recurrence. Both the left and bi-atrial procedures are successful in terms of restoring sinus rhythm. Left atrial ablation in severe cases and where the incision of right atrium is not needed is a reasonable choice.

  14. Electrophysiological determinant for induction of isthmus dependent counterclockwise and clockwise atrial flutter in humans.

    PubMed

    Lin, J L; Lai, L P; Lin, L J; Tseng, Y Z; Lien, W P; Huang, S K

    1999-01-01

    To investigate the electrophysiological determinant underlying the electrical induction of counterclockwise and clockwise isthmus dependent atrial flutter. The isthmus bordered by the inferior vena caval orifice-tricuspid annulus-coronary sinus ostium (IVCO-TA-CSO) has been assumed to be the site of both slow conduction and unidirectional block critical to the initiation of atrial flutter. Trans-isthmus and the global atrial conduction were studied in 25 patients with isthmus dependent atrial flutter (group A) and in 21 patients without atrial flutter (group B), by pacing at the coronary sinus ostium and the low lateral right atrium (LLRA) and mapping with a 20 pole Halo catheter in the right atrium. Mean (SD) fluoroscopic isthmus length between the coronary sinus ostium and LLRA sites was 28.1 (4.0) mm in group A and 28.0 (3.9) mm in group B (p = 0.95), but the trans-isthmus conduction velocity of both directions at various pacing cycle lengths was nearly halved in group A compared with group B (mean 0.39-0.46 m/s v 0.83-0.89 m/s, p < 0.0001). Pacing at coronary sinus ostium directly induced counterclockwise atrial flutter in 14 patients and pacing at LLRA induced clockwise atrial flutter in 11 patients, following abrupt unidirectional trans-isthmus block. Transient atrial tachyarrhythmias preceded the onset of atrial flutter in 10 counterclockwise and six clockwise cases of atrial flutter. None of the group B patients had inducible atrial flutter even in the presence of trans-isthmus block. The intra- and interatrial conduction times, as well as the conduction velocities at the right atrial free wall and the septum, were similar and largely within the normal range in both groups. Critical slowing of the trans-IVCO-TA-CSO isthmus conduction, but not the unidirectional block or the global atrial performance, is the electrophysiological determinant of the induction of counterclockwise and clockwise isthmus dependent atrial flutter in man.

  15. RR-Interval variance of electrocardiogram for atrial fibrillation detection

    NASA Astrophysics Data System (ADS)

    Nuryani, N.; Solikhah, M.; Nugoho, A. S.; Afdala, A.; Anzihory, E.

    2016-11-01

    Atrial fibrillation is a serious heart problem originated from the upper chamber of the heart. The common indication of atrial fibrillation is irregularity of R peak-to-R-peak time interval, which is shortly called RR interval. The irregularity could be represented using variance or spread of RR interval. This article presents a system to detect atrial fibrillation using variances. Using clinical data of patients with atrial fibrillation attack, it is shown that the variance of electrocardiographic RR interval are higher during atrial fibrillation, compared to the normal one. Utilizing a simple detection technique and variances of RR intervals, we find a good performance of atrial fibrillation detection.

  16. Automatic Detection of Atrial Fibrillation Using Basic Shannon Entropy of RR Interval Feature

    NASA Astrophysics Data System (ADS)

    Afdala, Adfal; Nuryani, Nuryani; Satriyo Nugroho, Anto

    2017-01-01

    Atrial Fibrillation is one of heart disease, that common characterized by irregularity heart beat. Atrial fibrillation leads to severe complications such as cardiac failure with the subsequent risk of a stroke. A method to detect atrial fibrillation is needed to prevent a risk of atrial fibrillation. This research uses data from physionet in atrial fibrillation database category. The performance of Shannon entropy has the highest accuracy if a threshold is 0.5 with accuracy 89.79%, sensitivity 91.04% and specificity 89.01%. Based on the result we get a conclusion, the ability of Shannon entropy to detect atrial fibrillation is good.

  17. Clinical implications of atrial isomerism.

    PubMed Central

    Chiu, I S; How, S W; Wang, J K; Wu, M H; Chu, S H; Lue, H C; Hung, C R

    1988-01-01

    Right atrial isomerism or left atrial isomerism is frequently diagnosed as situs ambiguous without further discrimination of the specific morbid anatomy. Thirty six cases of right atrial isomerism and seven cases of left atrial isomerism were collected from the records and pathological museum at the National Taiwan University Hospital. There was a necropsy report for 18 cases. In all patients one or more of the following conditions was met: (a) isomeric bronchial anatomy, (b) echocardiographic and angiocardiographic evidence of isomerism, and (c) surgical or necropsy evidence of abnormal atrial anatomy. An anomalous pulmonary venous connection was present in 55% of patients with right atrial isomerism; in left atrial isomerism one case (14%) had a partial anomalous pulmonary venous connection. Forty per cent of cases of anomalous pulmonary venous connection with right atrial isomerism had obstruction. Six (86%) of seven cases with left atrial isomerism had an ambiguous biventricular atrioventricular connection. In contrast, univentricular atrioventricular connection (26 of 36, 72%) was significantly more common in right atrial isomerism. A common atrioventricular valve was the most frequent mode of connection in both forms. Two discrete atrioventricular valves were significantly more common in left atrial isomerism. Atrioventricular valve regurgitation was detected in 14 cases. Double outlet right ventricle was the most common type of ventriculoarterial connection. The most commonly cited causes of death after either palliative or definitive operation were undetected anomalous pulmonary venous connection, pulmonary venous stricture, and uncorrected atrioventricular valve or aortic regurgitation complicated by abnormal coagulation. Although the prognosis is poor, successful operation depends on knowledge of the precise anatomical arrangement associated with atrial isomerism. Images Fig 1 Fig 2 Fig 3 PMID:3408620

  18. Effect of atrial systole on canine and porcine coronary blood flow.

    PubMed

    Bellamy, R F

    1981-09-01

    A feature of phasic coronary flow patterns recorded in conscious chronically instrumented dogs is the atrial cove--a transient depression of arterial flow that occurs during atrial systole. The association between the hemodynamic effects of atrial systole and the atrial cove was studied in anesthetized dogs and pigs with complete heart block. Many atrial coves are available for study in these preparations because atrial activity continues unabated during the diastolic ventricular arrest that follows cessation of electrical pacing. The effect of atrial systole is to translate the pressure-flow relation found during diastole to a higher intercept pressure without change in slope. The increase in the intercept pressure equals the increase in intramyocardial pressure measured with microtransducers embedded in the left ventricular wall. The decrement in flow during the atrial cove is a direct function of the change in intramyocardial pressure and an inverse function of coronary vascular resistance. Each atrial systole is associated with a forward flow transient in the coronary veins, the peak of which occurs at the same instant as does the nadir of atrial flow. These data suggest that the coronary vessels are acting as collapsible tubes and that the waterfall model of the coronary circulation is applicable. The following sequence is proposed to account for the atrial cove. Atrial systole ejects a bolus of blood into the left ventricle increasing both ventricular cavity and intramyocardial pressures. The increase in intramyocardial pressure raises the back pressure opposing coronary flow, reducing the arterial perfusion pressure gradient and causing flow to fall.

  19. Evaluation of atrial electromechanical conduction delay in case of hemodynamically insignificant rheumatic heart disease: A tissue Doppler study.

    PubMed

    Cagdas, Metin; Velibey, Yalcin; Guvenc, Tolga Sinan; Gungor, Baris; Guzelburc, Ozge; Calik, Nazmi; Ugur, Murat; Tekkesin, Ahmet Ilker; Gurkan, Kadir; Eren, Mehmet

    2015-01-01

    Atrial electromechanical delay (AEMD) that reflects delayed conduction may show us the clinical reflection of pathological changes in the atria. The main objective of the present study is to investigate AEMD in patients who had previous rheumatic carditis but without hemodynamically significant valvular disease. A total of 40 patients, previously diagnosed as rheumatic carditis but without significant valvular stenosis/regurgitation and atrial enlargement; and 39 age- and-sex matched controls were enrolled for the present study. Parameters of AEMD (lateral mitral annulus electromechanical delay, septal mitral annulus electromechanical delay and lateral tricuspid annulus electromechanical delay) were measured with tissue Doppler echocardiography and left intra-atrial and inter-atrial conduction times were calculated accordingly. A 24h ambulatory Holter monitoring was used in both groups to detect atrial fibrillation episodes and quantify atrial extrasystoles. Parameters of AEMD, including left intra-atrial and inter-atrial conduction times of subjects in the study group were longer compared to the control group (23.7 ± 7.0 vs. 18.3 ± 6.2). Increased AEMD is observed in patients with previous rheumatic carditis and no significant valvular stenosis/regurgitation and atrial enlargement, which may partly explain the increased incidence of atrial fibrillation observed in these patients.

  20. Effects of atorvastatin on atrial remodeling in a rabbit model of atrial fibrillation produced by rapid atrial pacing.

    PubMed

    Yang, Qian; Qi, Xiaoyong; Dang, Yi; Li, Yingxiao; Song, Xuelian; Hao, Xiao

    2016-06-24

    Accumulating evidence suggests that myeloperoxidase (MPO) is involved in atrial remodeling of atrial fibrillation (AF). Statins could reduce the MPO levels in patients with cardiovascular diseases. This study evaluated the effects of atorvastatin on MPO level and atrial remodeling in a rabbit model of pacing-induced AF. Eighteen rabbits were randomly divided into sham, control and atorvastatin groups. Rabbits in the control and atorvastatin groups were subjected to rapid atrial pacing (RAP) at 600 bpm for 3 weeks, and treated with placebo or atorvastatin (2.5 mg/kg/d), respectively. Rabbits in the sham group did not receive RAP. After 3 weeks of pacing, atrial structural and functional changes were assessed by echocardiography, atrial effective refractory period (AERP) and AF inducibility were measured by atrial electrophysiological examination, and histological changes were evaluated by Masson trichrome-staining. The L-type calcium channel α1c (Cav1.2), collagen I and III, MPO, matrix metalloproteinase (MMP)-2 and MMP-9 were analyzed by real time polymerase chain reaction and/or western blot. All rabbits were found to have maintained sinus rhythm after 3 weeks of RAP. Atrial burst stimulation induced sustained AF (>30 min) in 5, 4, and no rabbits in the control, atorvastatin, and sham groups, respectively. The AERP shortened and Cav1.2 mRNA level decreased in the control group, but these changes were suppressed in the atorvastatin group. Obvious left atrial enlargement and dysfunction was found in both control and atorvastatin groups. Compared with the control group, these echocardiograhic indices of left atrium did not differ in the atorvastatin group. Prominent atrial fibrosis and increased levels of collagen I and III were observed in the control group but not in the atorvastatin group. The mRNA and protein levels of MPO, MMP-2 and MMP-9 significantly increased in the control group, but these changes were prevented in the atorvastatin group. Treatment with atorvastatin prevented atrial remodeling in a rabbit model of RAP-induced AF. The reduction of levels of atrial MPO, MMP-2 and MMP-9 may contribute to the prevention of atorvastatin on atrial remodeling.

  1. [Prophylaxis of thromboembolism in atrial fibrillation: new oral anticoagulants and left atrial appendage closure].

    PubMed

    Zeus, Tobias; Kelm, Malte; Bode, Christoph

    2015-08-01

    Thrombo-embolic prophylaxis is a key element within the therapy of atrial fibrillation/atrial flutter. Besides new oral anticoagulants the concept of left atrial appendage occlusion has approved to be a good alternative option, especially in patients with increased risk of bleeding. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Increased susceptibility to atrial fibrillation secondary to atrial fibrosis in transgenic goats expressing transforming growth factor - B1

    USDA-ARS?s Scientific Manuscript database

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in people with significant morbidity and mortality. There is a strong association between atrial fibrosis and AF. Transforming growth factor B1 (TGF-B1) is an essential mediator of atrial fibrosis in animal models and human pat...

  3. Possible role for cryoballoon ablation of right atrial appendage tachycardia when conventional ablation fails.

    PubMed

    Amasyali, Basri; Kilic, Ayhan

    2015-06-01

    Focal atrial tachycardia arising from the right atrial appendage usually responds well to radiofrequency ablation; however, successful ablation in this anatomic region can be challenging. Surgical excision of the right atrial appendage has sometimes been necessary to eliminate the tachycardia and prevent or reverse the resultant cardiomyopathy. We report the case of a 48-year-old man who had right atrial appendage tachycardia resistant to multiple attempts at ablation with use of conventional radiofrequency energy guided by means of a 3-dimensional mapping system. The condition led to cardiomyopathy in 3 months. The arrhythmia was successfully ablated with use of a 28-mm cryoballoon catheter that had originally been developed for catheter ablation of paroxysmal atrial fibrillation. To our knowledge, this is the first report of cryoballoon ablation without isolation of the right atrial appendage. It might also be an alternative to epicardial ablation or surgery when refractory atrial tachycardia originates from the right atrial appendage.

  4. Percutaneous management of coronary sinus atrial septal defect: two cases representing the spectrum for device closure and a review of the literature.

    PubMed

    Sandeep, Nefthi; Slack, Michael C

    2014-10-01

    Coronary sinus atrial septal defects are the rarest defects of the atrial septum comprising <1% of the five different types of atrial septal defects. Despite the widespread adoption of percutaneous device closure of secundum atrial septal defects, the published experience with percutaneous device closure of coronary sinus atrial septal defects is limited to only a few isolated case reports because of uncertainty regarding safety and efficacy. Open-heart surgical repair remains the treatment of choice for coronary sinus atrial septal defects, although this may not be the only treatment option in selected cases. Herein we describe our own experience with two patients with different clinical presentations and our method of successful percutaneous coronary sinus atrial septal defect closure in each. We then present a review of the anatomic spectrum of coronary sinus atrial septal defects along with a review of contemporary surgical and percutaneous device treatment.

  5. Right versus left atrial pacing in patients with sick sinus syndrome and paroxysmal atrial fibrillation (Riverleft study): study protocol for randomized controlled trial.

    PubMed

    Ramdjan, Tanwier T T K; van der Does, Lisette J M E; Knops, Paul; Res, Jan C J; de Groot, Natasja M S

    2014-11-17

    The incidence of sick sinus syndrome will increase due to population ageing. Consequently, this will result in an increase in the number of pacemaker implantations. The atrial lead is usually implanted in the right atrial appendage, but this position may be ineffective for prevention of atrial fibrillation. It has been suggested that pacing distally in the coronary sinus might be more successful in preventing atrial fibrillation episodes. The aim of this trial is to study the efficacy of distal coronary sinus versus right atrial appendage pacing in preventing atrial fibrillation episodes in patients with sick sinus syndrome. This study is designed as a multicenter, randomized controlled trial. Patients with sick sinus syndrome and at least one atrial fibrillation episode of 30 seconds or more in the six months before recruitment will be eligible for participation in this study.All participants will be randomized between pacing distally in the coronary sinus and right atrial appendage. Randomization is stratified for all participating centers. Conventional dual-chamber pacemakers with advanced home monitoring functionality will be implanted. The ventricular lead will be implanted in the right ventricular apex. The first three months of the 36-month follow-up period are considered as run-in time. During the pre-randomization visit and follow-up, an interview, electrocardiogram and pacemaker assessment will be performed, prescribed antiarrhythmic medication will be reviewed and patients will be asked to complete an SF-36 questionnaire. An echocardiographic examination will be conducted in the pre-randomization phase and at the end of each follow-up year. Home monitoring will be used to send daily reports in case of atrial fibrillation episodes. This randomized controlled trial is the first in which home monitoring will be used to compare atrial fibrillation recurrences between pacing in the distal coronary sinus or right atrial appendage. Home monitoring gives the opportunity to accurately detect atrial fibrillation episodes and to study characteristics of atrial fibrillation episodes. Should distal coronary sinus pacing significantly diminish atrial fibrillation recurrences, this study will redefine the preferential location of an atrial lead for preventive pacing. Current Controlled Trials ISRCTN65911661, registered on 8 July 2013.

  6. Atrial myocardial nox2 containing NADPH oxidase activity contribution to oxidative stress in mitral regurgitation: potential mechanism for atrial remodeling.

    PubMed

    Chang, Jen-Ping; Chen, Mien-Cheng; Liu, Wen-Hao; Yang, Cheng-Hsu; Chen, Chien-Jen; Chen, Yung-Lung; Pan, Kuo-Li; Tsai, Tzu-Hsien; Chang, Hsueh-Wen

    2011-01-01

    Oxidative stress is linked with several cardiovascular diseases. However, the NADPH oxidase activity in severe mitral regurgitation patients with and without atrial fibrillation has not yet been explored. This study involved 16 adult patients (eight patients with persistent atrial fibrillation and eight with sinus rhythm) with severe mitral and moderate-to-severe tricuspid regurgitation and five control patients without mitral and tricuspid disease. Atrial tissues of the right and left atrial appendages were obtained during surgery. Superoxide anion production was measured by lucigenin-enhanced chemiluminescence, and the expression of nox2 containing NADPH oxidase mRNA was measured by quantitative real-time RT-PCR. Additionally, immunohistochemical study was performed. NADPH-stimulated superoxide release was significantly higher than basal superoxide production from right [5671.9±3498.7 vs. 232.7±70.0 relative light units per second per milligram of protein (RLU s(-1) mg protein(-1)), P=.008) and left atrial homogenates (6475.1±1890.8 vs. 229.0±79.6 RLU s(-1) mg protein(-1), P=.008) in atrial fibrillation patients. The NADPH-stimulated superoxide release from right atrial homogenates was also significantly higher than basal superoxide production in sinus patients (6809.1±1327.1 vs. 244.2±65.5 RLU s(-1) mg protein(-1), P=.008). Additionally, there was a borderline significant correlation between NADPH-stimulated superoxide production from left atrial homogenates and left atrial sizes (r=0.683, P=.062) in atrial fibrillation patients. Membrane-bound nox2 containing NADPH oxidase mRNA expression was increased and was similar in both the atrial fibrillation patients and sinus patients. The NADPH-stimulated superoxide production in right atrial homogenates in control atrial samples was 1863.7±137.2 RLU s(-1) mg protein(-1). Immunohistochemical study demonstrated increased expression of nox2 in myocytes with moderate-to-severe myolysis and hypertrophy. Results of this study demonstrate that membrane-bound nox2 containing NADPH oxidase activity and expression in the atrial myocardium is increased in patients with severe mitral regurgitation, possibly contributing to atrial remodeling in this clinical setting. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Primary aldosteronism and thyroid disorders in atrial fibrillation: A Swedish nationwide case-control study.

    PubMed

    Mourtzinis, Georgios; Adamsson Eryd, Samuel; Rosengren, Annika; Björck, Lena; Adiels, Martin; Johannsson, Gudmundur; Manhem, Karin

    2018-05-01

    Background Atrial fibrillation is associated with hyperthyroidism. Patients with primary aldosteronism have an increased prevalence of atrial fibrillation. However, the prevalence of primary aldosteronism in the atrial fibrillation population is unknown. Aim This nationwide case-control study aimed to compare the prevalence of primary aldosteronism and thyroid disorders in patients with atrial fibrillation with that of age- and sex-matched controls. Methods We identified all atrial fibrillation cases in Sweden between 1987 and 2013 ( n = 713,569) by using the Swedish National Patient Register. A control cohort without atrial fibrillation was randomly selected from the Swedish Total Population Register with a case to control ratio of 1:2. This control cohort was matched for age, sex and place of birth ( n = 1,393,953). Results The prevalence of primary aldosteronism in December 2013 was 0.056% in the atrial fibrillation cohort and 0.024% in controls. At the same time, the prevalence of hypothyroidism was 5.9% in the atrial fibrillation cohort and 3.7% in controls. The prevalence of hyperthyroidism was 2.3% in the atrial fibrillation cohort and 0.8% in controls. Conclusion This study shows, for the first time, a doubled prevalence of primary aldosteronism in a large cohort of patients with atrial fibrillation compared with the general population. There is also an increased prevalence of hypo- and hyper-thyroidism in patients with atrial fibrillation compared with the general population.

  8. Resource Utilization Related to Atrial Fibrillation After Coronary Artery Bypass Grafting

    PubMed Central

    Hravnak, Marilyn; Hoffman, Leslie A.; Saul, Melissa I.; Zullo, Thomas G.; Whitman, Gayle R.

    2013-01-01

    Background Studies of resource utilization by patients with new-onset atrial fibrillation after coronary artery bypass grafting have addressed only length of stay and bed charges. Objective To compare resource utilization between patients with new-onset atrial fibrillation and patients without atrial fibrillation after isolated coronary artery bypass grafting. Methods Retrospective review of clinical and administrative electronic databases for 720 subjects who underwent isolated coronary artery bypass grafting with cardiopulmonary bypass in 25 months at one medical center. The prevalence of atrial fibrillation was determined, and resource utilization in various hospital cost centers was compared between subjects with and without atrial fibrillation. Results The prevalence of new-onset atrial fibrillation was 33.1%. Compared with subjects without atrial fibrillation, subjects with atrial fibrillation had a longer stay (5.8 ± 2.4 vs 4.4 ± 1.2 days, P< .001), more days receiving mechanical ventilation (P=.002) and oxygen therapy (P< .001), and higher rates of readmission to the intensive care unit (4.6% vs 0.2%, P< .001). Subjects with atrial fibrillation also had more laboratory tests (P< .001) and more days receiving cardiac drugs, heparin, diuretics, and electrolytes. Subjects with atrial fibrillation had higher total postoperative charges ($57261 ± $17 101 vs $50905 ± $10062, P= .001), a mean difference of $6356. The mean differences were greatest for bed charges ($1642), laboratory charges ($1215), pharmacy ($989), and respiratory care ($582). Conclusion The economic impact of atrial fibrillation after coronary artery bypass grafting has been underestimated. PMID:12022486

  9. Atrial anatomy and function postcardioversion: insights from transthoracic and transesophageal echocardiography.

    PubMed

    Manning, W J; Silverman, D I

    1996-01-01

    Echocardiography provides a valuable tool for the evaluation and assessment of atrial function in patients with atrial fibrilation (AF). Atrial morphology after restoration of sinus rhythm is dynamic, with a decrease in atrial size if sinus rhythm is maintained and atrial growth among those with sustained AF. Restoration of electrocardiographic sinus rhythm is frequently accompanied by relatively depressed atrial mechanical function, with recovery that appears to be related to multiple factors, including the duration of AF before cardioversion and the mode of cardioversion. Such delay appears to confer ongoing risk for thrombus formation and thromboembolism in the days after cardioversion and argues strongly for the need to maintain therapeutic anticoagulation during the pericardioversion and postcardioversion period.

  10. Echocardiographic imaging techniques with subcostal and right parasternal longitudinal views in detecting sinus venosus atrial septal defects.

    PubMed

    McDonald, R W; Rice, M J; Reller, M D; Marcella, C P; Sahn, D J

    1996-01-01

    Sinus venosus atrial septal defects are frequently missed and difficult to visualize with conventional two-dimensional echocardiographic views. Using modified subcostal and right parasternal longitudinal views, nine patients were found to have a sinus venosus atrial septal defect. The modified subcostal view showed a sinus venosus atrial septal defect in all nine patients; three patients had secundum atrial septal defects as well. The right parasternal view detected only six patients with sinus venosus atrial septal defect. Partial anomalous pulmonary venous return was diagnosed in seven patients using these views. The combination of subcostal and right parasternal longitudinal imaging views will improve the detection of sinus venosus atrial septal defects.

  11. Pioglitazone inhibits angiotensin II-induced atrial fibroblasts proliferation via NF-κB/TGF-β1/TRIF/TRAF6 pathway

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiao-qing; Liu, Xu, E-mail: xkliuxu@126.com; Wang, Quan-xing, E-mail: wqxejd@126.com

    2015-01-01

    The exact mechanisms underlying inhibitory effects of pioglitazone (Pio) on Angiotensin II (AngII)-induced atrial fibrosis are complex and remain largely unknown. In the present study, we examined the effect of Pio on AngII-induced mice atrial fibrosis in vivo and atrial fibroblasts proliferation in vitro. In vivo study showed that AngII infusion induced atrial fibrosis and increased expressions of Toll/IL-1 receptor domain-containing adaptor inducing IFN-β (TRIF) and tumor necrosis factor receptor associated factor 6 (TRAF6) in mice models. However, those effects could be attenuated by Pio (P<0.01). As for in vitro experiment, Pio suppressed AngII-induced atrial fibroblasts proliferation via nuclear factor-κB/transformingmore » growth factor-β1/TRIF/TRAF6 signaling pathway in primary cultured mice atrial fibroblasts (P<0.01). In conclusion, suppression of Pio on AngII-induced atrial fibrosis might be related to its inhibitory effects on above signaling pathway. - Highlights: • Angiotensin II increased atrial fibrosis and related gene expressions in mice. • Angiotensin II induced atrial fibroblasts proliferation by activating signaling pathway. • Pioglitazone reversed both aforementioned changes.« less

  12. Concomitant surgical closure of left atrial appendage: A systematic review and meta-analysis.

    PubMed

    Ando, Masahiko; Funamoto, Masaki; Cameron, Duke E; Sundt, Thoralf M

    2018-03-12

    Although percutaneous closure of the left atrial appendage is supported as a potential alternative to lifelong anticoagulation in patients with atrial fibrillation, comprehensive evidence on surgical left atrial appendage closure in heart surgery is limited. We conducted a meta-analysis of studies comparing patients who underwent open cardiac surgery with or without left atrial appendage closure. A literature search was performed on PubMed, Embase, and Cochrane Trials databases. Outcomes of interest were 30-day/in-hospital mortality and cerebrovascular accident. I 2 statistics were used to evaluate heterogeneity, and publication bias was evaluated by Begg's and Egger's tests. We reviewed 1284 articles and selected for main analysis 7 articles including 3897 patients (1963 in the left atrial appendage closure group and 1934 in the non-left atrial appendage closure group). Among the 7 studies, 3 were randomized-controlled studies, 3 were propensity-matched studies, and 1 was a case-matching study. At 30-day/in-hospital follow-up, left atrial appendage closure was significantly associated with decreased risk of mortality and cerebrovascular accident (odds ratio, 0.384, 95% confidence interval, 0.233-0.631 for mortality, and odds ratio, 0.622, 95% confidence interval, 0.388-0.998 for cerebrovascular accident). Stratified analysis demonstrated that this association was more prominent in preoperative atrial fibrillation strata. Concomitant surgical left atrial appendage closure should be considered at the time of open cardiac surgery, particularly among those in atrial fibrillation preoperatively. The benefit of left atrial appendage closure for patients not in atrial fibrillation and for those undergoing nonvalvular surgery is still unclear. Further prospective investigations are indicated. Copyright © 2018. Published by Elsevier Inc.

  13. Prospective randomized study to assess the efficacy of site and rate of atrial pacing on long-term progression of atrial fibrillation in sick sinus syndrome: Septal Pacing for Atrial Fibrillation Suppression Evaluation (SAFE) Study.

    PubMed

    Lau, Chu-Pak; Tachapong, Ngarmukos; Wang, Chun-Chieh; Wang, Jing-Feng; Abe, Haruhiko; Kong, Chi-Woon; Liew, Reginald; Shin, Dong-Gu; Padeletti, Luigi; Kim, You-Ho; Omar, Razali; Jirarojanakorn, Kreingkrai; Kim, Yoon-Nyun; Chen, Mien-Cheng; Sriratanasathavorn, Charn; Munawar, Muhammad; Kam, Ruth; Chen, Jan-Yow; Cho, Yong-Keun; Li, Yi-Gang; Wu, Shu-Lin; Bailleul, Christophe; Tse, Hung-Fat

    2013-08-13

    Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF. We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79-1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79-1.74; P=0.69) did not prevent the development of persistent AF. In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF. URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00419640.

  14. Atrial Fibrillation: Complications

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: Complications Past Issues / Winter 2015 Table of Contents ... has two major complications—stroke and heart failure. Atrial Fibrillation and Stroke Click to enlarge image This illustration ...

  15. Assessing strategies for heart failure with preserved ejection fraction at the outpatient clinic.

    PubMed

    Jorge, Antonio José Lagoeiro; Rosa, Maria Luiza Garcia; Ribeiro, Mario Luiz; Fernandes, Luiz Claudio Maluhy; Freire, Monica Di Calafiori; Correia, Dayse Silva; Teixeira, Patrick Duarte; Mesquita, Evandro Tinoco

    2014-09-01

    Heart failure with preserved ejection fraction (HFPEF) is the most common form of heart failure (HF), its diagnosis being a challenge to the outpatient clinic practice. To describe and compare two strategies derived from algorithms of the European Society of Cardiology Diastology Guidelines for the diagnosis of HFPEF. Cross-sectional study with 166 consecutive ambulatory patients (67.9±11.7 years; 72% of women). The strategies to confirm HFPEF were established according to the European Society of Cardiology Diastology Guidelines criteria. In strategy 1 (S1), tissue Doppler echocardiography (TDE) and electrocardiography (ECG) were used; in strategy 2 (S2), B-type natriuretic peptide (BNP) measurement was included. In S1, patients were divided into groups based on the E/E'ratio as follows: GI, E/E'> 15 (n = 16; 9%); GII, E/E'8 to 15 (n = 79; 48%); and GIII, E/E'< 8 (n = 71; 43%). HFPEF was confirmed in GI and excluded in GIII. In GII, TDE [left atrial volume index (LAVI) ≥ 40 mL/m2; left ventricular mass index LVMI) > 122 for women and > 149 g/m2 for men] and ECG (atrial fibrillation) parameters were assessed, confirming HFPEF in 33 more patients, adding up to 49 (29%). In S2, patients were divided into three groups based on BNP levels. GI (BNP > 200 pg/mL) consisted of 12 patients, HFPEF being confirmed in all of them. GII (BNP ranging from 100 to 200 pg/mL) consisted of 20 patients with LAVI > 29 mL/m2, or LVMI ≥ 96 g/m2 for women or ≥ 116 g/m2 for men, or E/E'≥ 8 or atrial fibrillation on ECG, and the diagnosis of HFPEF was confirmed in 15. GIII (BNP < 100 pg/mL) consisted of 134 patients, 26 of whom had the diagnosis of HFPEF confirmed when GII parameters were used. Measuring BNP levels in S2 identified 4 more patients (8%) with HFPEF as compared with those identified in S1. The association of BNP measurement and TDE data is better than the isolated use of those parameters. BNP can be useful in identifying patients whose diagnosis of HF had been previously excluded based only on TDE findings.

  16. Early beneficial effect of preservation of papillo-annular continuity in mitral valve replacement on left ventricular function.

    PubMed

    Dilip, D; Chandra, A; Rajashekhar, D; Padmanabhan, M

    2001-05-01

    Impairment of left ventricular (LV) function after mitral valve replacement (MVR) has been the most important factor to determine morbidity and mortality. With this in mind, LV performance in the postoperative period was assessed with and without preservation of papillo-annular continuity in MVR. Between March 1994 and August 1998, a total of 383 valve prostheses (202 MVR, 65 AVR, 58 MVR+AVR) were implanted in 325 patients, 177 of whom underwent MVR with Starr Edwards ball cage prostheses (the study group). Of these 177 patients, 105 had MVR with preservation of the posterior mitral leaflet (group I), and 72 had conventional MVR (group II). Predominant lesions were mitral stenosis in 81, mitral regurgitation in 42, and mixed mitral lesion (MS/MR) in 54. Concomitant tricuspid valve annuloplasty was performed in 13, and atrial septal defect repair in five. Sixteen patients underwent MVR for mitral restenosis. In-vivo performance of the prostheses and LV function was evaluated by M-mode and Doppler echocardiography. At 3-6 months clinical improvement was seen in NYHA class, with reduction in cardiothoracic ratio among patients with preserved papillo-annular continuity, irrespective of lesion type. Significant reductions (p <0.05) were seen in left atrial dimensions (54.10 +/- 8.79 preop. versus 44.64 +/- 8.54 postop.; p <0.05), left ventricular end-diastolic dimensions (LVEDD) (50.84 +/- 10.42 preop. versus 41.21 +/- 7.16 postop.; p <0.05) and end-systolic dimensions (LVESD) (34.76 +/- 7.94 preop. versus 28.81 +/- 5.79 postop.; p <0.05) in patients who had their posterior mitral leaflet preserved with significant improvement in ejection fraction (60.31 +/- 8.22 versus 64.47 +/- 7.93; p <0.05). Further analysis of data in group I patients showed significant reductions in left atrial dimensions, LVESD and peak gradient, along with improved ejection fraction compared with conventional (group II) patients. Deterioration in LV function in patients undergoing conventional MVR indicates chordal resection as a putative mechanism. This study supports the concept that maintenance of continuity between the mitral annulus and papillary muscles has a beneficial effect on postoperative LV function, and is particularly important in patients with mitral stenosis with depressed preoperative LV systolic function.

  17. Arrhythmogenic substrate at the interventricular septum as a target site for radiofrequency catheter ablation of recurrent ventricular tachycardia in left dominant arrhythmogenic cardiomyopathy.

    PubMed

    Havranek, Stepan; Palecek, Tomas; Kovarnik, Tomas; Vitkova, Ivana; Psenicka, Miroslav; Linhart, Ales; Wichterle, Dan

    2015-03-10

    Left dominant arrhythmogenic cardiomyopathy (LDAC) is a rare condition characterised by progressive fibrofatty replacement of the myocardium of the left ventricle (LV) in combination with ventricular arrhythmias of LV origin. A thirty-five-year-old male was referred for evaluation of recurrent sustained monomorphic ventricular tachycardia (VT) of 200 bpm and right bundle branch block (RBBB) morphology. Cardiac magnetic resonance imaging showed late gadolinium enhancement distributed circumferentially in the epicardial layer of the LV free wall myocardium including the rightward portion of the interventricular septum (IVS). The clinical RBBB VT was reproduced during the EP study. Ablation at an LV septum site with absence of abnormal electrograms and a suboptimum pacemap rendered the VT of clinical morphology noninducible. Three other VTs, all of left bundle branch block (LBBB) pattern, were induced by programmed electrical stimulation. The regions corresponding to abnormal electrograms were identified and ablated at the mid-to-apical RV septum and the anteroseptal portion of the right ventricular outflow tract. No abnormalities were found at the RV free wall including the inferolateral peritricuspid annulus region. Histological examination confirmed the presence of abnormal fibrous and adipose tissue with myocyte reduction in endomyocardial samples taken from both the left and right aspects of the IVS. LDAC rarely manifests with sustained monomorphic ventricular tachycardia. In this case, several VTs of both RBBB and LBBB morphology were amenable to endocardial radiofrequency catheter ablation.

  18. Increasing Prevalence of Atrial Fibrillation and Permanent Atrial Arrhythmias in Congenital Heart Disease.

    PubMed

    Labombarda, Fabien; Hamilton, Robert; Shohoudi, Azadeh; Aboulhosn, Jamil; Broberg, Craig S; Chaix, Marie A; Cohen, Scott; Cook, Stephen; Dore, Annie; Fernandes, Susan M; Fournier, Anne; Kay, Joseph; Macle, Laurent; Mondésert, Blandine; Mongeon, François-Pierre; Opotowsky, Alexander R; Proietti, Anna; Rivard, Lena; Ting, Jennifer; Thibault, Bernard; Zaidi, Ali; Khairy, Paul

    2017-08-15

    Atrial arrhythmias are the most common complication encountered in the growing and aging population with congenital heart disease. This study sought to assess the types and patterns of atrial arrhythmias, associated factors, and age-related trends. A multicenter cohort study enrolled 482 patients with congenital heart disease and atrial arrhythmias, age 32.0 ± 18.0 years, 45.2% female, from 12 North American centers. Qualifying arrhythmias were classified by a blinded adjudicating committee. The most common presenting arrhythmia was intra-atrial re-entrant tachycardia (IART) (61.6%), followed by atrial fibrillation (28.8%), and focal atrial tachycardia (9.5%). The proportion of arrhythmias due to IART increased with congenital heart disease complexity from 47.2% to 62.1% to 67.0% in patients with simple, moderate, and complex defects, respectively (p = 0.0013). Atrial fibrillation increased with age to surpass IART as the most common arrhythmia in those ≥50 years of age (51.2% vs. 44.2%; p < 0.0001). Older age (odds ratio [OR]: 1.024 per year; 95% confidence interval [CI]: 1.010 to 1.039; p = 0.001) and hypertension (OR: 2.00; 95% CI: 1.08 to 3.71; p = 0.029) were independently associated with atrial fibrillation. During a mean follow-up of 11.3 ± 9.4 years, the predominant arrhythmia pattern was paroxysmal in 62.3%, persistent in 28.2%, and permanent in 9.5%. Permanent atrial arrhythmias increased with age from 3.1% to 22.6% in patients <20 years to ≥50 years, respectively (p < 0.0001). IART is the most common presenting atrial arrhythmia in patients with congenital heart disease, with a predominantly paroxysmal pattern. However, atrial fibrillation increases in prevalence and atrial arrhythmias progressively become permanent as the population ages. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Significantly Elevated C-Reactive Protein Levels After Epicardial Clipping of the Left Atrial Appendage.

    PubMed

    Verberkmoes, Niels J; Akca, Ferdi; Vandevenne, Ann-Sofie; Jacobs, Luuk; Soliman Hamad, Mohamed A; van Straten, Albert H M

    Besides mechanical and anatomical changes of the left atrium, epicardial closure of the left atrial appendage has also possible homeostatic effects. The aim of this study was to assess whether epicardial clipping of the left atrial appendage has different biochemical effects compared with complete removal of the left atrial appendage. Eighty-two patients were included and underwent a totally thoracoscopic AF ablation procedure. As part of the procedure, the left atrial appendage was excluded with an epicardial clip (n = 57) or the left atrial appendage was fully amputated with an endoscopic vascular stapler (n = 25). From all patients' preprocedural and postprocedural blood pressure, electrolytes and inflammatory parameters were collected. The mean age and left atrial volume index were comparable between the epicardial clip and stapler group (64 ± 8 years vs. 60 ± 9 years, P = non-significant; 44 ± 15 mL/m vs. 40 ± 13 mL/m, P = non-significant). Patients receiving left atrial appendage clipping had significantly elevated C-reactive protein levels compared with patients who had left atrial appendage stapling at the second, third, and fourth postoperative day (225 ± 84 mg/L vs. 149 ± 76 mg/L, P = 0.002, 244 ± 78 vs. 167 ± 76, P = 0.004, 190 ± 74 vs. 105 ± 48, P < 0.001, respectively). Patients had a significant decrease in sodium levels, systolic, and diastolic blood pressure at 24 and 72 hours after left atrial appendage closure. However, this was comparable for both the left atrial appendage clipping and stapling group. Increased activation of the inflammatory response was observed after left atrial appendage clipping compared with left atrial appendage stapling. Furthermore, a significant decrease in blood pressure was observed after surgical removal of the left atrial appendage. Whether the inflammatory response affects the outcome of arrhythmia surgery needs to be further evaluated.

  20. Embolic risk in atrial fibrillation that arises from hyperthyroidism: review of the medical literature.

    PubMed

    Traube, Elie; Coplan, Neil L

    2011-01-01

    Atrial fibrillation, the most common cardiac complication of hyperthyroidism, occurs in an estimated 10% to 25% of overtly hyperthyroid patients. The prevalence of atrial fibrillation increases with age in the general population and in thyrotoxic patients. Other risk factors for atrial fibrillation in thyrotoxic patients include male sex, ischemic or valvular heart disease, and congestive heart failure. The incidence of arterial embolism or stroke in thyrotoxic atrial fibrillation is less clear. There are many reports of arterial thromboembolism associated with hyperthyroidism, including cases of young adults without coexisting risk factors other than thyrotoxic atrial fibrillation. The use of anticoagulative agents to prevent thromboembolic sequelae of thyrotoxic atrial fibrillation is controversial: National organizations provide conflicting recommendations in their practice guidelines. Herein, we review the medical literature and examine the evidence behind the recommendations in order to determine the best approach to thromboembolic prophylaxis in patients who have atrial fibrillation that is associated with hyperthyroidism.

  1. Embolic Risk in Atrial Fibrillation that Arises from Hyperthyroidism

    PubMed Central

    Traube, Elie; Coplan, Neil L.

    2011-01-01

    Atrial fibrillation, the most common cardiac complication of hyperthyroidism, occurs in an estimated 10% to 25% of overtly hyperthyroid patients. The prevalence of atrial fibrillation increases with age in the general population and in thyrotoxic patients. Other risk factors for atrial fibrillation in thyrotoxic patients include male sex, ischemic or valvular heart disease, and congestive heart failure. The incidence of arterial embolism or stroke in thyrotoxic atrial fibrillation is less clear. There are many reports of arterial thromboembolism associated with hyperthyroidism, including cases of young adults without coexisting risk factors other than thyrotoxic atrial fibrillation. The use of anticoagulative agents to prevent thromboembolic sequelae of thyrotoxic atrial fibrillation is controversial: national organizations provide conflicting recommendations in their practice guidelines. Herein, we review the medical literature and examine the evidence behind the recommendations in order to determine the best approach to thromboembolic prophylaxis in patients who have atrial fibrillation that is associated with hyperthyroidism. PMID:21720457

  2. Development of a transgenic goat model wih cardiac-specific overexpression of transforming growth factor - {beta} 1 to study the relationship between atrial fibrosis and atrial fibrillation

    USDA-ARS?s Scientific Manuscript database

    Studies on patients, large animal models and transgenic mouse models have shown a strong association of atrial fibrosis with atrial fibrillation (AF). However, it is unclear whether there is a causal relationship between atrial fibrosis and AF or whether these events appear as a result of independen...

  3. Enzyme replacement therapy with agalsidase beta improves cardiac involvement in Fabry's disease.

    PubMed

    Spinelli, L; Pisani, A; Sabbatini, M; Petretta, M; Andreucci, M V; Procaccini, D; Lo Surdo, N; Federico, S; Cianciaruso, B

    2004-08-01

    Fabry's disease is an X-linked lysosomal storage disease caused by a deficiency of alpha-galactosidase that results in an accumulation of neutral glycosphingolipids throughout the body, including the cardiovascular system. Fabry cardiomyopathy, characterized by progressive severe concentric left ventricular (LV) hypertrophy, is very frequent and is the most important cause of death in affected patients. Enzyme replacement therapy (ERT) allows a specific treatment for this disease, however, there are very few data on the effectiveness of therapy on cardiac involvement. Nine patients with Fabry cardiac disease were studied on basal condition and after 6 and 12 months of treatment with algasidase beta (Fabrazyme). A complete clinical, electrocardiographic and echocardiographic evaluation was performed in all patients. Interpretable Doppler recordings of transmitral flow and pulmonary flow velocity curves were also acquired. At baseline, the patients with Fabry's disease had increased LV septum and posterior wall thickness, normal LV fractional shortening, LV ejection fraction, normal Doppler parameters of mitral inflow but a duration of pulmonary vein flow velocity wave exceeding that of the mitral wave at atrial systole. ERT did not affect heart rate and arterial pressure. LV internal diameters did not change, there was a slight but not significant decrease in the LV posterior wall thickening and a progressive decrease in the interventricular septum thickening (p < 0.025) and in LV mass (p < 0.001) The difference in duration between pulmonary vein flow velocity wave and mitral wave at atrial systole significantly decreased (p < 0.001). These results suggest that ERT in patients with Fabry cardiomyopathy is able to reduce the LV mass and ameliorate the LV stiffness. Copyright 2004 Blackwell Munksgaard

  4. Prognostic impact of heart rate in elderly with systolic heart failure and concomitant atrial fibrillation.

    PubMed

    Barywani, Salim; Petzold, Max

    2017-08-01

    The present study aimed to investigate the impact of resting heart rate (HR) on 5-year all-cause mortality in patients ≥80 years with heart failure (HF) with reduced ejection fraction (HFrEF) and concomitant atrial fibrillation (AF) after optimal up-titration of beta-blockers (BBs). Patients (n = 185) aged ≥80 years with HF and left ventricular ejection fraction ≤40% were included between January 2000 and January 2008 from two university hospitals, Sahlgrenska and Östra and retrospectively studied from January 2 to May 30, 2013. Up-titrations of guideline recommended medications were performed at HF outpatient clinics. Of whole study population, 54% (n= 100) had AF. After optimal up-titration of BBs and angiotensin converting enzyme inhibitors (ACEIs)/angiotensin receptor blockers (ARBs), mean HR in patients with AF was 73 ± 15 beats/minute (bpm), 36% had resting HR ≤65 bpm. Five-year all-cause mortality among patients with AF was significantly lower in patients with HR ≤65 bpm (63%) compared to HR >65 (80%). Cox proportional-hazard regression analysis adjusted for clinically important baseline variables and doses of ACEIs/ARBs and BBs demonstrated resting HR ≤65 bpm as an independent predictor of improved survival compared to resting HR >65 bpm (HR 0.3, 95%CI 0.1-0.7, P 0.005). In octogenarians with HFrEF and concomitant AF, lowering resting HR to levels as low as HR ≤65 bpm was still associated with improved survival from all-cause mortality. Our data indicate that mortality in AF became comparable to SR when patients were on maximally up-titrated beta-blocker doses with HR as low as 75 bpm.

  5. Influence of atrial fibrillation on the mortality of patients with heart failure with preserved ejection fraction.

    PubMed

    Franco, Jonathan; Formiga, Francesc; Cepeda, Jose; Llacer, Pau; Arévalo-Lorido, Juan; Cerqueiro, Jose; González-Franco, Alvaro; Epelde, Francesc; Manzano, Luis; Montero Pérez-Barquero, Manuel

    2018-05-23

    The impact of atrial fibrillation (AF) on the prognosis of heart failure with preserved ejection fraction (HFpEF) is still the subject of debate. We analysed the influence of AF on the prognosis on mortality and readmission in patients with HFpEF. Prospective observational study in 1,971 patients with HFpEF, who were admitted for acute heart failure. Patients were divided into 2 groups according to the presence or absence of AF. We analysed mortality, readmissions and combined mortality/readmissions at one year follow-up. A total of 1,177 (59%) patients had AF, mean age 80.3 (7.8) years and 1,233 (63%) were women. Patients with HFpEF and AF were older, female, greater valvular aetiology and lower comorbidity measured by the Charlson index. At the one year follow-up, 430 (22%) patients had died and 840 (43%) had been readmitted. In the 2 groups analysed, there was no difference in all-cause mortality (22 vs. 21%; P=.739, AF vs. no-AF, respectively) or cardiovascular causes (9.6 vs. 8.2%; P=.739, AF vs. no-AF, respectively). In the multivariable analysis, factors associated with higher mortality were: age, male, valvular aetiology, uric acid, and comorbidity. In the analysis of the subgroup with HFpEF with AF, the presence of chronic AF compared to de novo AF was associated with higher mortality (HR 1,716; 95% CI 1,099-2,681; P=.018). In patients with HFpEF, the presence of AF is frequent. During the one-year follow-up, the presence of AF does not influence mortality or readmissions in patients with HFpEF. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  6. Non invasive evaluation of cardiomechanics in patients undergoing MitrClip procedure

    PubMed Central

    2013-01-01

    Background In the last recent years a new percutaneous procedure, the MitraClip, has been validated for the treatment of mitral regurgitation. MitraClip procedure is a promising alternative for patients unsuitable for surgery as it reduces the risk of death related to surgery ensuring a similar result. Few data are present in literature about the variation of hemodynamic parameters and ventricular coupling after Mitraclip implantation. Methods Hemodynamic data of 18 patients enrolled for MitraClip procedure were retrospectively reviewed and analyzed. Echocardiographic measurements were obtained the day before the procedure (T0) and 21 ± 3 days after the procedure (T1), including evaluation of Ejection Fraction, mitral valve regurgitation severity and mechanism, forward Stroke Volume, left atrial volume, estimated systolic pulmonary pressure, non invasive echocardiographic estimation of single beat ventricular elastance (Es(sb)), arterial elastance (Ea) measured as systolic pressure • 0.9/ Stroke Volume, ventricular arterial coupling (Ea/Es(sb) ratio). Data were expressed as median and interquartile range. Measures obtained before and after the procedure were compared using Wilcoxon non parametric test for paired samples. Results Mitraclip procedure was effective in reducing regurgitation. We observed an amelioration of echocardiographic parameters with a reduction of estimated systolic pulmonary pressure (45 to 37,5 p = 0,0002) and left atrial volume (110 to 93 p = 0,0001). Despite a few cases decreasing in ejection fraction (37 to 35 p = 0,035), the maintained ventricular arterial coupling after the procedure (P = 0,67) was associated with an increasing in forward stroke volume (60,3 to 78 p = 0,05). Conclusion MitraClip is effective in reducing mitral valve regurgitation and determines an amelioration of hemodynamic parameters with preservation of ventricular arterial coupling. PMID:23642140

  7. Impact of obstructive sleep apnea on cardiac organ damage in patients with acute ischemic stroke.

    PubMed

    Mattaliano, Paola; Lombardi, Carolina; Sangalli, Davide; Faini, Andrea; Corrà, Barbara; Adobbati, Laura; Branzi, Giovanna; Mariani, Davide; Silani, Vincenzo; Parati, Gianfranco

    2018-06-01

    Both obstructive sleep apnea (OSA) and cardiac organ damage have a crucial role in acute ischemic stroke. Our aim is to explore the relationship between OSA and cardiac organ damage in acute stroke patients. A total of 130 consecutive patients with acute ischemic stroke were enrolled. Patients underwent full multichannel 24-h polysomnography for evaluation of OSA and echocardiography to evaluate left ventricle (LV) mass index (LV mass/BSA, LV mass/height), thickness of interventricular septum (IVS) and posterior wall (LVPW), LV ejection fraction and left atrium enlargement. Information on occurrence of arterial hypertension and its treatment before stroke was obtained from patients' history. 61.9% (70) of patients, mostly men (67.1%), with acute stroke had OSA (AHI > 10). Patients with acute stroke and OSA showed a significant increase (P < 0.05) of LV mass index, IVS and LVPW thickness and a significant left atrial enlargement as compared with patients without OSA. LV ejection fraction was not significantly different in stroke patients with and without OSA and was within normal limits. No relationship was found among cardiac alterations, occurrence of OSA and history of hypertension. Acute stroke patients with OSA had higher LV mass and showed greater left atrial enlargement than patients without OSA. This study confirms the high prevalence of OSA in stroke patients, suggesting also an association between OSA and cardiac target organ damage. Our finding of structural LV abnormalities in acute stroke patients with OSA suggests a potential role of OSA as contributing factor in determining both cerebrovascular and cardiac damage, even in absence of clear link with a history of blood pressure elevation.

  8. Advanced electrophysiologic mapping systems: an evidence-based analysis.

    PubMed

    2006-01-01

    To assess the effectiveness, cost-effectiveness, and demand in Ontario for catheter ablation of complex arrhythmias guided by advanced nonfluoroscopy mapping systems. Particular attention was paid to ablation for atrial fibrillation (AF). Tachycardia Tachycardia refers to a diverse group of arrhythmias characterized by heart rates that are greater than 100 beats per minute. It results from abnormal firing of electrical impulses from heart tissues or abnormal electrical pathways in the heart because of scars. Tachycardia may be asymptomatic, or it may adversely affect quality of life owing to symptoms such as palpitations, headaches, shortness of breath, weakness, dizziness, and syncope. Atrial fibrillation, the most common sustained arrhythmia, affects about 99,000 people in Ontario. It is associated with higher morbidity and mortality because of increased risk of stroke, embolism, and congestive heart failure. In atrial fibrillation, most of the abnormal arrhythmogenic foci are located inside the pulmonary veins, although the atrium may also be responsible for triggering or perpetuating atrial fibrillation. Ventricular tachycardia, often found in patients with ischemic heart disease and a history of myocardial infarction, is often life-threatening; it accounts for about 50% of sudden deaths. Treatment of Tachycardia The first line of treatment for tachycardia is antiarrhythmic drugs; for atrial fibrillation, anticoagulation drugs are also used to prevent stroke. For patients refractory to or unable to tolerate antiarrhythmic drugs, ablation of the arrhythmogenic heart tissues is the only option. Surgical ablation such as the Cox-Maze procedure is more invasive. Catheter ablation, involving the delivery of energy (most commonly radiofrequency) via a percutaneous catheter system guided by X-ray fluoroscopy, has been used in place of surgical ablation for many patients. However, this conventional approach in catheter ablation has not been found to be effective for the treatment of complex arrhythmias such as chronic atrial fibrillation or ventricular tachycardia. Advanced nonfluoroscopic mapping systems have been developed for guiding the ablation of these complex arrhythmias. Four nonfluoroscopic advanced mapping systems have been licensed by Health Canada: CARTO EP mapping System (manufactured by Biosense Webster, CA) uses weak magnetic fields and a special mapping/ablation catheter with a magnetic sensor to locate the catheter and reconstruct a 3-dimensional geometry of the heart superimposed with colour-coded electric potential maps to guide ablation. EnSite System (manufactured by Endocardial Solutions Inc., MN) includes a multi-electrode non-contact catheter that conducts simultaneous mapping. A processing unit uses the electrical data to computes more than 3,000 isopotential electrograms that are displayed on a reconstructed 3-dimensional geometry of the heart chamber. The navigational system, EnSite NavX, can be used separately with most mapping catheters. The LocaLisa Intracardiac System (manufactured by Medtronics Inc, MN) is a navigational system that uses an electrical field to locate the mapping catheter. It reconstructs the location of the electrodes on the mapping catheter in 3-dimensional virtual space, thereby enabling an ablation catheter to be directed to the electrode that identifies abnormal electric potential. Polar Constellation Advanced Mapping Catheter System (manufactured by Boston Scientific, MA) is a multielectrode basket catheter with 64 electrodes on 8 splines. Once deployed, each electrode is automatically traced. The information enables a 3-dimensional model of the basket catheter to be computed. Colour-coded activation maps are reconstructed online and displayed on a monitor. By using this catheter, a precise electrical map of the atrium can be obtained in several heartbeats. A systematic search of Cochrane, MEDLINE and EMBASE was conducted to identify studies that compared ablation guided by any of the advanced systems to fluoroscopy-guided ablation of tachycardia. English-language studies with sample sizes greater than or equal to 20 that were published between 2000 and 2005 were included. Observational studies on safety of advanced mapping systems and fluoroscopy were also included. Outcomes of interest were acute success, defined as termination of arrhythmia immediately following ablation; long-term success, defined as being arrhythmia free at follow-up; total procedure time; fluoroscopy time; radiation dose; number of radiofrequency pulses; complications; cost; and the cost-effectiveness ratio. Quality of the individual studies was assessed using established criteria. Quality of the overall evidence was determined by applying the GRADE evaluation system. (3) Qualitative synthesis of the data was performed. Quantitative analysis using Revman 4.2 was performed when appropriate. Quality of the Studies Thirty-four studies met the inclusion criteria. These comprised 18 studies on CARTO (4 randomized controlled trials [RCTs] and 14 non-RCTs), 3 RCTs on EnSite NavX, 4 studies on LocaLisa Navigational System (1 RCT and 3 non-RCTs), 2 studies on EnSite and CARTO, 1 on Polar Constellation basket catheter, and 7 studies on radiation safety. The quality of the studies ranged from moderate to low. Most of the studies had small sample sizes with selection bias, and there was no blinding of patients or care providers in any of the studies. Duration of follow-up ranged from 6 weeks to 29 months, with most having at least 6 months of follow-up. There was heterogeneity with respect to the approach to ablation, definition of success, and drug management before and after the ablation procedure. Evidence is based on a small number of small RCTS and non-RCTS with methodological flaws.Advanced nonfluoroscopy mapping/navigation systems provided real time 3-dimensional images with integration of anatomic and electrical potential information that enable better visualization of areas of interest for ablationAdvanced nonfluoroscopy mapping/navigation systems appear to be safe; they consistently shortened the fluoroscopy duration and radiation exposure.Evidence suggests that nonfluoroscopy mapping and navigation systems may be used as adjuncts to rather than replacements for fluoroscopy in guiding the ablation of complex arrhythmias.Most studies showed a nonsignificant trend toward lower overall failure rate for advanced mapping-guided ablation compared with fluoroscopy-guided mapping.Pooled analyses of small RCTs and non-RCTs that compared fluoroscopy- with nonfluoroscopy-guided ablation of atrial fibrillation and atrial flutter showed that advanced nonfluoroscopy mapping and navigational systems:Yielded acute success rates of 69% to 100%, not significantly different from fluoroscopy ablation.Had overall failure rates at 3 months to 19 months of 1% to 40% (median 25%).Resulted in a 10% relative reduction in overall failure rate for advanced mapping guided-ablation compared to fluoroscopy guided ablation for the treatment of atrial fibrillation.Yielded added benefit over fluoroscopy in guiding the ablation of complex arrhythmia. The advanced systems were shown to reduce the arrhythmia burden and the need for antiarrhythmic drugs in patients with complex arrhythmia who had failed fluoroscopy-guided ablationBased on predominantly observational studies, circumferential PV ablation guided by a nonfluoroscopy system was shown to do the following:Result in freedom from atrial fibrillation (with or without antiarrhythmic drug) in 75% to 95% of patients (median 79%). This effect was maintained up to 28 months.Result in freedom from atrial fibrillation without antiarrhythmic drugs in 47% to 95% of patients (median 63%).Improve patient survival at 28 months after the procedure as compared with drug therapy.Require special skills; patient outcomes are operator dependent, and there is a significant learning curve effect.Complication rates of pulmonary vein ablation guided by an advanced mapping/navigation system ranged from 0% to 10% with a median of 6% during a follow-up period of 6 months to 29 months.The complication rate of the study with the longest follow-up was 8%.The most common complications of advanced catheter-guided ablation were stroke, transient ischemic attack, cardiac tamponade, myocardial infarction, atrial flutter, congestive heart failure, and pulmonary vein stenosis. A small number of cases with fatal atrial-esophageal fistula had been reported and were attributed to the high radiofrequency energy used rather than to the advanced mapping systems. An Ontario-based economic analysis suggests that the cumulative incremental upfront costs of catheter ablation of atrial fibrillation guided by advanced nonfluoroscopy mapping could be recouped in 4.7 years through cost avoidance arising from less need for antiarrhythmic drugs and fewer hospitalization for stroke and heart failure. Expert Opinion Expert consultants to the Medical Advisory Secretariat noted the following: Nonfluoroscopy mapping is not necessary for simple ablation procedures (e.g., typical flutter). However, it is essential in the ablation of complex arrhythmias including these:Symptomatic, drug-refractory atrial fibrillationArrhythmias in people who have had surgery for congenital heart disease (e.g., macro re-entrant tachycardia in people who have had surgery for congenital heart disease).Ventricular tachycardia due to myocardial infarctionAtypical atrial flutterAdvanced mapping systems represent an enabling technology in the ablation of complex arrhythmias. The ablation of these complex cases would not have been feasible or advisable with fluoroscopy-guided ablation and, therefore, comparative studies would not be feasible or ethical in such cases. (ABSTRACT TRUNCATED)

  9. Left ventricular filling under elevated left atrial pressure

    NASA Astrophysics Data System (ADS)

    Gaddam, Manikantam; Samaee, Milad; Santhanakrishnan, Arvind

    2017-11-01

    Left atrial pressure (LAP) is elevated in diastolic dysfunction, where left ventricular (LV) filling is impaired due to increase in ventricular stiffness. The impact of increasing LAP and LV stiffness on intraventricular filling hemodynamics remains unclear. We conducted particle image velocimetry and hemodynamics measurements in a left heart simulator (LHS) under increasing LAP and LV stiffness at a heart rate of 70 bpm. The LHS consisted of a flexible-walled LV physical model fitted within a fluid-filled chamber. LV wall motion was generated by a piston pump that imparted pressure fluctuations in the chamber. Resistance and compliance elements in the flow loop were adjusted to obtain bulk physiological hemodynamics in the least stiff LV model. Two LV models of increasing stiffness were subsequently tested under unchanged loop settings. LAP was varied between 5-20 mm Hg for each LV model, by adjusting fluid level in a reservoir upstream of the LV. For constant LV stiffness, increasing LAP lowered cardiac output (CO), while ejection fraction (EF) and E/A ratio were increased. For constant LAP, increasing LV stiffness lowered CO and EF, and increased E/A ratio. The implications of these altered hemodynamics on intraventricular filling vortex characteristics will be presented.

  10. Impact of the severity of end-stage liver disease in cardiac structure and function.

    PubMed

    Silvestre, Odilson Marcos; Bacal, Fernando; de Souza Ramos, Danusa; Andrade, Jose L; Furtado, Meive; Pugliese, Vincenzo; Belleti, Elisangela; Andraus, Wellington; Carrilho, Flair José; Carneiro D'Albuquerque, Luiz Augusto; Queiroz Farias, Alberto

    2013-01-01

    The impact of end-stage liver disease (ESLD) in cardiac remodeling of patients with cirrhosis is unknown. Our aim was to correlate the severity of ESLD with morphologic and functional heart changes. 184 patients underwent a protocol providing data on the severity of ESLD and undergoing echocardiography to assess the diameters of the left atrium and right ventricle; the systolic and diastolic diameters of the left ventricle, interventricular septum, and posterior wall of the left ventricle; systolic pulmonary artery pressure; ejection fraction; and diastolic function. Severity of ESLD was assessed by the Model for End-Stage Liver Disease (MELD) score. Left-atrial diameter (r = 0.323; IC 95% 0.190-0.455; p < 0.001), left-ventricular diastolic diameter (r = 0.177; IC 95% 0.033-0.320; p = 0.01) and systolic pulmonary artery pressure (r = 0.185; IC 95% 0.036-0.335; p = 0.02) significantly correlated with MELD score. Patients with MELD ≥ 16 had significantly higher left-atrial diameter and systolic pulmonary artery pressure, compared with patients with MELD scores < 16 points. Changes in cardiac structure and function correlate with the severity of ESLD.

  11. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2000-11-01

    Devices capable of monitoring and treating atrial tachyarrhythmias provide information about the natural history of the arrhythmias and potentially can influence their natural course by electrical therapy early after onset. Types of atrial arrhythmias and efficacy of device therapies were evaluated in 30 patients implanted with the Medtronic model 7250 Jewel AF implantable cardioverter defibrillator (ICD). All patients had structural heart disease and documented sustained ventricular and atrial arrhythmias (27 with atrial fibrillation [AF]) before implant. Twenty patients were taking amiodarone, and three were taking sotalol. During 20+/-10 months of follow-up, 600 atrial arrhythmia recurrences were documented in 50% of patients. AF was diagnosed in 19%, fast polymorphic atrial tachycardia (AT) in 20%, fast monomorphic AT in 57%, and slow AT in 4% of episodes. The two adaptive pacing therapies, burst and ramp, together with the 50-Hz burst, were successful in 57% of detected atrial arrhythmias. Burst and ramp were responsible for 49% and 50-Hz burst for 51% of successfully treated arrhythmias; 33% of the episodes terminated spontaneously. No ventricular proarrhythmia was observed due to atrial pacing therapies. In 30% of episodes, dual chamber pacing was required due to post termination bradycardia. Atrial arrhythmia recurrences in patients with dilated cardiomyopathy were not amenable to pacing therapies. Several aspects of atrial arrhythmia diagnosis, therapy, and documentation that are specific for functioning of the Jewel AF are discussed. Atrial arrhythmias in ICD patients with diseased hearts who are taking Class III antiarrhythmics frequently had longer cycle lengths than AF. Half of these arrhythmias could be terminated with pacing therapies; one third terminated spontaneously.

  12. Coronary sinus signal amplitude predicts left atrial scarring.

    PubMed

    Attanasio, Philipp; Qaiyumi, Daniel; Röhle, Robert; Wutzler, Alexander; Safak, Erdal; Muntean, Bogdan; Boldt, Leif-Hendrik; Pieske, Burkert; Haverkamp, Wilhelm; Huemer, Martin

    2017-12-22

    Left atrial scarring is recognised as a critical component in the maintenance of atrial fibrillation and is associated with the failure of interventional treatment. Diminished bipolar voltage (LV) has been proposed as a useful tool for left atrial scar quantification. We hypothesised that, due to its anatomic location, signals on the coronary sinus catheter might be used to predict the amount of left atrial low voltage. A total of 124 patients (42% women, average age 66 ± 9 years) were included. Forty-one with paroxysmal and 83 with persistent atrial fibrillation. Left atrial low-voltage (<0.5 mV, measured during sinus rhythm) area size and distribution varied considerably among the included patients (mean: 34.9%; maximum: 94.6%; minimum: 0.4%). Spearman correlation revealed a strong negative correlation between bipolar voltage of the signals on the coronary sinus catheter and the amount of left atrial scarring (R = -0.778, p < .0001). The optimal CS voltage cut off for prediction of left atrial low-voltage size of ≥50% was 1.9 mV with an area-under-the receiver-operating-characteristic (ROC) curve of 0.982, a sensitivity of 97% and a specificity of 98%. There is a strong negative correlation between the size of left atrial low-voltage areas (LVA) and coronary sinus signal amplitude. With increasing left atrial LVA size, CS signal amplitudes decrease, and vice versa. On the basis of these findings, average CS signal amplitudes of ≤1.9 mV can be used as a predictor for a left atrial low-voltage size of ≥50%.

  13. Impact of Major Pulmonary Resections on Right Ventricular Function: Early Postoperative Changes.

    PubMed

    Elrakhawy, Hany M; Alassal, Mohamed A; Shaalan, Ayman M; Awad, Ahmed A; Sayed, Sameh; Saffan, Mohammad M

    2018-01-15

    Right ventricular (RV) dysfunction after pulmonary resection in the early postoperative period is documented by reduced RV ejection fraction and increased RV end-diastolic volume index. Supraventricular arrhythmia, particularly atrial fibrillation, is common after pulmonary resection. RV assessment can be done by non-invasive methods and/or invasive approaches such as right cardiac catheterization. Incorporation of a rapid response thermistor to pulmonary artery catheter permits continuous measurements of cardiac output, right ventricular ejection fraction, and right ventricular end-diastolic volume. It can also be used for right atrial and right ventricular pacing, and for measuring right-sided pressures, including pulmonary capillary wedge pressure. This study included 178 patients who underwent major pulmonary resections, 36 who underwent pneumonectomy assigned as group (I) and 142 who underwent lobectomy assigned as group (II). The study was conducted at the cardiothoracic surgery department of Benha University hospital in Egypt; patients enrolled were operated on from February 2012 to February 2016. A rapid response thermistor pulmonary artery catheter was inserted via the right internal jugular vein. Preoperatively the following was recorded: central venous pressure, mean pulmonary artery pressure, pulmonary capillary wedge pressure, cardiac output, right ventricular ejection fraction and volumes. The same parameters were collected in fixed time intervals after 3 hours, 6 hours, 12 hours, 24 hours, and 48 hours postoperatively. For group (I): There were no statistically significant changes between the preoperative and postoperative records in the central venous pressure and mean arterial pressure; there were no statistically significant changes in the preoperative and 12, 24, and 48 hour postoperative records for cardiac index; 3 and 6 hours postoperative showed significant changes. There were statistically significant changes between the preoperative and postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index, in all postoperative records. For group (II): There were no statistically significant changes between the preoperative and all postoperative records for the central venous pressure, mean arterial pressure and cardiac index. There were statistically significant changes between the preoperative and postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index in all postoperative records. There were statistically significant changes between the two groups in all postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index. There is right ventricular dysfunction early after major pulmonary resection caused by increased right ventricular afterload. This dysfunction is more present in pneumonectomy than in lobectomy. Heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction, and right ventricular end diastolic volume index are significantly affected by pulmonary resection.

  14. A novel atrial volume reduction technique to enhance the Cox maze procedure: initial results.

    PubMed

    Marui, Akira; Nishina, Takeshi; Tambara, Keiichi; Saji, Yoshiaki; Shimamoto, Takeshi; Nishioka, Masahiko; Ikeda, Tadashi; Komeda, Masashi

    2006-11-01

    Large left atrial diameter is reported to be a predictor for recurrent atrial fibrillation after the Cox maze procedure, and left atrial diameter by itself influences the chance of sinus rhythm recovery, as well as maintenance of sinus rhythm. However, additional cut-and-sew procedures to decrease left atrial diameter extend operative time and can cause bleeding. Thus we developed a no-bleeding, faster, and therefore less invasive left atrial volume reduction technique to enhance the Cox maze procedure. The modified Cox maze III procedure with cryoablation or the left atrial maze procedure in association with mitral valve surgery was performed in 80 patients with atrial fibrillation and enlarged left atria (> or =60 mm). Among them, 44 patients had the concomitant volume reduction technique (VR group); continuous horizontal mattress sutures for left atrial plication were placed on the left atrial wall along the pulmonary vein isolation line. Cryoablation was applied to the suture line so that the plicated left atrium is anatomically and electrically isolated. Another 36 patients did not have the volume reduction technique (control group). The VR group had preoperative left atrial diameters similar to those of the control group (67.1 +/- 7.8 vs 64.5 +/- 6.7 mm) and a longer preoperative duration of atrial fibrillation (14.1 +/- 5.4 vs 9.5 +/- 5.1 years, P < .05) but had smaller postoperative left atrial diameters (47.6 +/- 6.3 vs 62.1 +/- 7.9 mm, P < .01). There were no differences in mean crossclamp/bypass time and chest tube drainage for 12 hours between the groups. Twelve months after surgical intervention, the sinus rhythm recovery rate of the VR group was better than that of the control group (90% vs 69%, P < .05). Even in patients with long-standing atrial fibrillation and an enlarged left atrium, maze procedures concomitant with the novel left atrial volume reduction technique improved the sinus rhythm recovery rate without increasing complications. Although further study with a larger number of patients and a longer follow-up period is needed, this safe and thus far potent technique that catheter-based ablation cannot copy might extend indication of the Cox maze procedure for patients with tough atrial fibrillation.

  15. Effects of ANP receptor antagonists on ANP secretion from adult rat cultured atrial myocytes.

    PubMed

    Nachshon, S; Zamir, O; Matsuda, Y; Zamir, N

    1995-03-01

    Atrial natriuretic peptide (ANP) is a hormone-secreted predominantly by atrial myocytes. ANP exerts many of its actions via activation of the particulate guanylyl cyclase receptor ANPR-A and the formation of guanosine 3',5'-cyclic monophosphate (cGMP), which serves as a second messenger in the target cells. Using membrane-permeable cGMP analogues (8-bromo-cGMP and dibutyryl- cGMP), we first tested the hypothesis that ANP secretion by adult rat cultured atrial myocytes can be modulated through the second messenger cGMP. Second, we examined the effects of two competitive ANPR-A receptor antagonists, namely HS-142-1 and anantin, on cGMP formation and ANP secretion from cultured atrial myocytes. Cultured atrial myocytes secreted large quantities of immunoreactive (ir) ANP under basal conditions. We found that cGMP analogues inhibited basal irANP secretion from cultured atrial myocytes, whereas HS-142-1 and anantin had stimulating effects. HS-142-1 and anantin reduced cGMP formation in cultured atrial myocytes at basal conditions. These results suggest an autoregulatory mechanism of ANP secretion by atrial myocytes in an autocrine/paracrine fashion.

  16. [Typical atrial flutter: Diagnosis and therapy].

    PubMed

    Thomas, Dierk; Eckardt, Lars; Estner, Heidi L; Kuniss, Malte; Meyer, Christian; Neuberger, Hans-Ruprecht; Sommer, Philipp; Steven, Daniel; Voss, Frederik; Bonnemeier, Hendrik

    2016-03-01

    Typical, cavotricuspid-dependent atrial flutter is the most common atrial macroreentry tachycardia. The incidence of atrial flutter (typical and atypical forms) is age-dependent with 5/100,000 in patients less than 50 years and approximately 600/100,000 in subjects > 80 years of age. Concomitant heart failure or pulmonary disease further increases the risk of typical atrial flutter.Patients with atrial flutter may present with symptoms of palpitations, reduced exercise capacity, chest pain, or dyspnea. The risk of thromboembolism is probably similar to atrial fibrillation; therefore, the same antithrombotic prophylaxis is required in atrial flutter patients. Acutely symptomatic cases may be subjected to cardioversion or pharmacologic rate control to relieve symptoms. Catheter ablation of the cavotricuspid isthmus represents the primary choice in long-term therapy, associated with high procedural success (> 97 %) and low complication rates (0.5 %).This article represents the third part of a manuscript series designed to improve professional education in the field of cardiac electrophysiology. Mechanistic and clinical characteristics as well as management of isthmus-dependent atrial flutter are described in detail. Electrophysiological findings and catheter ablation of the arrhythmia are highlighted.

  17. [The contribution of inflammatory process in pathogenesis and natural history of atrial fibrillation].

    PubMed

    Zyśko, Dorota; Gajek, Jacek; Mazurek, Walentyna

    2005-02-01

    The inflammatory process plays important role in pathogenesis of some cardiovascular diseases. Atrial fibrillation is atrial arrhythmia with rapid, asynchronous activation of atrial myocytes. The inflammatory process can be responsible for atrial electrical and anatomical remodeling and therefore shifts towards arrhythmia persistence. The presence of systemic inflammation may be assessed by means of C-reactive protein (CRP) measurement. Maximal concentration of CRP coincidences with the peak of paroxysmal atrial fibrillation occurrence in patients after cardiac surgery. In patients with sinus rhythm the concentration of CRP is a risk factor for this arrhythmia in long-term follow-up. In patients with atrial fibrillation mean CRP concentration is 2-fold higher comparing to control group. CRP concentration is higher in patients with chronic than paroxysmal form of this arrhythmia. High CRP level predicts worse results of direct current cardioversion and more frequent paroxysms of atrial fibrillation during follow-up. Besides of, the patients with echocardiographic signs of thromboembolic risk have higher CRP levels than control subjects. There is no data about the influence of anti-inflammatory therapy on atrial fibrillation or its recurrences.

  18. Management of atrial fibrillation.

    PubMed

    Moukabary, Talal; Gonzalez, Mario D

    2015-07-01

    Atrial fibrillation is a very common clinical problem with a high prevalence that is expected to rise over time because of increasing risk factors (eg, age, obesity, hypertension). This high prevalence is also associated with high cost, because atrial fibrillation represents about 1% of overall health care spending. The management of atrial fibrillation involves multiple facets: (1) management of underlying disease if present and the management of atrial fibrillation risk factors, (2) prevention of thromboembolism, (3) control of the ventricular rate during atrial fibrillation, and (4) restoration and maintenance of normal sinus rhythm. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Effect of verapamil on immediate recurrence of atrial fibrillation.

    PubMed

    Daoud, E G; Hummel, J D; Augostini, R; Williams, S; Kalbfleisch, S J

    2000-11-01

    The purpose of this study was to assess the effect of verapamil on immediate recurrences of atrial fibrillation occurring after successful electrical cardioversion. The effect of verapamil on the recurrence of atrial fibrillation within 5 minutes after successful transthoracic cardioversion was assessed in 19 (5%) of 364 patients undergoing electrical cardioversion. The mean duration of atrial fibrillation was 4.44+/-3.0 months. In the 19 patients, cardioversion was successful after each of three consecutive cardioversion attempts per patient; however, atrial fibrillation recurred 0.4+/-0.3 minutes after cardioversion. Verapamil 10 mg was administered intravenously and a fourth cardioversion was performed. Cardioversion after verapamil was successful in each patient, and atrial fibrillation did not recur in 9 (47%) of 19 patients (P < 0.001 vs before verapamil). In the remaining 10 patients in whom atrial fibrillation recurred, the duration of sinus rhythm was significantly longer compared with before verapamil (3.6+/-2.4 min, P < 0.001). The density of atrial ectopy occurring after cardioversion was significantly less after verapamil (21+/-14 ectopic beats per min) compared with before verapamil (123+/-52 ectopic beats per min, P < 0.001). Among patients with immediate recurrence of atrial fibrillation after electrical cardioversion, acute calcium channel blockade by verapamil reduces recurrence of atrial fibrillation and extends the duration of sinus rhythm.

  20. Temporary atrial epicardial pacing as prophylaxis against atrial fibrillation after heart surgery: a meta-analysis.

    PubMed

    Daoud, Emile G; Snow, Rick; Hummel, John D; Kalbfleisch, Steven J; Weiss, Raul; Augostini, Ralph

    2003-02-01

    Recent studies have reported the use of temporary epicardial atrial pacing as prophylaxis for postoperative atrial fibrillation (AF). The aim of this study was to assess the effect of pacing therapies for prevention of postoperative AF using meta-analysis. Using a computerized MEDLINE search, eight pacing prophylaxis trials with 776 patients were included in the meta-analysis. Trials compared control patients to patients randomized to right atrial, left atrial, or biatrial pacing used in conjunction with either fixed high-rate pacing or overdrive pacing. Overdrive biatrial pacing (OR 2.6, CI 1.4-4.8), overdrive right atrial pacing (OR 1.8, CI 1.1-2.7), and fixed high-rate biatrial pacing (OR 2.5, CI 1.3-5.1) demonstrated a significant antiarrhythmic effect for prevention of AF after open heart surgery. Furthermore, studies investigating overdrive left atrial pacing and fixed high-rate right atrial pacing have been underpowered to assess efficacy. Biatrial overdrive and fixed high-rate pacing and right atrial fixed high-rate pacing reduced the risk of new-onset AF after open heart surgery, and the relative risk reduction is approximately 2.5-fold. These results imply that various pacing algorithms are useful as a nonpharmacologic method to prevent postoperative AF.

  1. Physiological variation in left atrial transverse orientation does not influence orthogonal P-wave morphology.

    PubMed

    Petersson, Richard; Mosén, Henrik; Steding-Ehrenborg, Katarina; Carlson, Jonas; Faxén, Lisa; Mohtadi, Alan; Platonov, Pyotr G; Holmqvist, Fredrik

    2017-03-01

    It has previously been demonstrated that orthogonal P-wave morphology in healthy athletes does not depend on atrial size, but the possible impact of left atrial orientation on P-wave morphology remains unknown. In this study, we investigated if left atrial transverse orientation affects P-wave morphology in different populations. Forty-seven patients with atrial fibrillation, 21 patients with arrhythmogenic right ventricular cardiomyopathy, 67 healthy athletes, and 56 healthy volunteers were included. All underwent cardiac magnetic resonance imaging or computed tomography and the orientation of the left atrium was determined. All had 12-lead electrocardiographic recordings, which were transformed into orthogonal leads and orthogonal P-wave morphology was obtained. The median left atrial transverse orientation was 87 (83, 91) degrees (lower and upper quartiles) in the total study population. There was no difference in left atrial transverse orientation between individuals with different orthogonal P-wave morphologies. The physiological variation in left atrial orientation was small within as well as between the different populations. There was no difference in left atrial transverse orientation between subjects with type 1 and type 2 P-wave morphology, implying that in this setting the P-wave morphology was more dependent on atrial conduction than orientation. © 2016 Wiley Periodicals, Inc.

  2. Orthogonal P-wave morphology is affected by intra-atrial pressures.

    PubMed

    Petersson, Richard; Smith, J Gustav; Larsson, David A; Reitan, Öyvind; Carlson, Jonas; Platonov, Pyotr; Holmqvist, Fredrik

    2017-12-06

    It has previously been shown that the morphology of the P-wave neither depends on atrial size in healthy subjects with physiologically enlarged atria nor on the physiological anatomical variation in transverse orientation of the left atrium. The present study aimed to investigate if different pressures in the left and right atrium are associated with different P-wave morphologies. 38 patients with isolated, increased left atrial pressure, 51 patients with isolated, increased right atrial pressure and 76 patients with biatrially increased pressure were studied. All had undergone right heart catheterization and had 12-lead electrocardiographic recordings, which were transformed into vectorcardiograms for detailed P-wave morphology analysis. Normal P-wave morphology (type 1) was more common in patients with isolated increased pressure in the right atrium while abnormal P-wave morphology (type 2) was more common in the groups with increased left atrial pressure (P = 0.032). Moreover, patients with increased left atrial pressure, either isolated or in conjunction with increased right atrial pressure, had significantly more often a P-wave morphology with a positive deflection in the sagittal plane (P = 0.004). Isolated elevated right atrial pressure was associated with normal P-wave morphology while left-sided atrial pressure elevation, either isolated or in combination with right atrial pressure elevation, was associated with abnormal P-wave morphology.

  3. Atorvastatin can ameliorate left atrial stunning induced by radiofrequency ablation for atrial fibrillation.

    PubMed

    Xie, Ruiqin; Yang, Yingtao; Cui, Wei; Yin, Hongning; Zheng, Hongmei; Zhang, Jidong; You, Ling

    2017-09-01

    The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P < 0.05). In summary, atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.

  4. High Molecular Weight Fibroblast Growth Factor-2 in the Human Heart Is a Potential Target for Prevention of Cardiac Remodeling

    PubMed Central

    Santiago, Jon-Jon; McNaughton, Leslie J.; Koleini, Navid; Ma, Xin; Bestvater, Brian; Nickel, Barbara E.; Fandrich, Robert R.; Wigle, Jeffrey T.; Freed, Darren H.; Arora, Rakesh C.; Kardami, Elissavet

    2014-01-01

    Fibroblast growth factor 2 (FGF-2) is a multifunctional protein synthesized as high (Hi-) and low (Lo-) molecular weight isoforms. Studies using rodent models showed that Hi- and Lo-FGF-2 exert distinct biological activities: after myocardial infarction, rat Lo-FGF-2, but not Hi-FGF-2, promoted sustained cardioprotection and angiogenesis, while Hi-FGF-2, but not Lo-FGF-2, promoted myocardial hypertrophy and reduced contractile function. Because there is no information regarding Hi-FGF-2 in human myocardium, we undertook to investigate expression, regulation, secretion and potential tissue remodeling-associated activities of human cardiac (atrial) Hi-FGF-2. Human patient-derived atrial tissue extracts, as well as pericardial fluid, contained Hi-FGF-2 isoforms, comprising, respectively, 53%(±20 SD) and 68% (±25 SD) of total FGF-2, assessed by western blotting. Human atrial tissue-derived primary myofibroblasts (hMFs) expressed and secreted predominantly Hi-FGF-2, at about 80% of total. Angiotensin II (Ang II) up-regulated Hi-FGF-2 in hMFs, via activation of both type 1 and type 2 Ang II receptors; the ERK pathway; and matrix metalloprotease-2. Treatment of hMFs with neutralizing antibodies selective for human Hi-FGF-2 (neu-AbHi-FGF-2) reduced accumulation of proteins associated with fibroblast-to-myofibroblast conversion and fibrosis, including α-smooth muscle actin, extra-domain A fibronectin, and procollagen. Stimulation of hMFs with recombinant human Hi-FGF-2 was significantly more potent than Lo-FGF-2 in upregulating inflammation-associated proteins such as pro-interleukin-1β and plasminogen-activator-inhibitor-1. Culture media conditioned by hMFs promoted cardiomyocyte hypertrophy, an effect that was prevented by neu-AbHi-FGF-2 in vitro. In conclusion, we have documented that Hi-FGF-2 represents a substantial fraction of FGF-2 in human cardiac (atrial) tissue and in pericardial fluid, and have shown that human Hi-FGF-2, unlike Lo-FGF-2, promotes deleterious (pro-fibrotic, pro-inflammatory, and pro-hypertrophic) responses in vitro. Selective targeting of Hi-FGF-2 production may, therefore, reduce pathological remodelling in the human heart. PMID:24827991

  5. High molecular weight fibroblast growth factor-2 in the human heart is a potential target for prevention of cardiac remodeling.

    PubMed

    Santiago, Jon-Jon; McNaughton, Leslie J; Koleini, Navid; Ma, Xin; Bestvater, Brian; Nickel, Barbara E; Fandrich, Robert R; Wigle, Jeffrey T; Freed, Darren H; Arora, Rakesh C; Kardami, Elissavet

    2014-01-01

    Fibroblast growth factor 2 (FGF-2) is a multifunctional protein synthesized as high (Hi-) and low (Lo-) molecular weight isoforms. Studies using rodent models showed that Hi- and Lo-FGF-2 exert distinct biological activities: after myocardial infarction, rat Lo-FGF-2, but not Hi-FGF-2, promoted sustained cardioprotection and angiogenesis, while Hi-FGF-2, but not Lo-FGF-2, promoted myocardial hypertrophy and reduced contractile function. Because there is no information regarding Hi-FGF-2 in human myocardium, we undertook to investigate expression, regulation, secretion and potential tissue remodeling-associated activities of human cardiac (atrial) Hi-FGF-2. Human patient-derived atrial tissue extracts, as well as pericardial fluid, contained Hi-FGF-2 isoforms, comprising, respectively, 53%(±20 SD) and 68% (±25 SD) of total FGF-2, assessed by western blotting. Human atrial tissue-derived primary myofibroblasts (hMFs) expressed and secreted predominantly Hi-FGF-2, at about 80% of total. Angiotensin II (Ang II) up-regulated Hi-FGF-2 in hMFs, via activation of both type 1 and type 2 Ang II receptors; the ERK pathway; and matrix metalloprotease-2. Treatment of hMFs with neutralizing antibodies selective for human Hi-FGF-2 (neu-AbHi-FGF-2) reduced accumulation of proteins associated with fibroblast-to-myofibroblast conversion and fibrosis, including α-smooth muscle actin, extra-domain A fibronectin, and procollagen. Stimulation of hMFs with recombinant human Hi-FGF-2 was significantly more potent than Lo-FGF-2 in upregulating inflammation-associated proteins such as pro-interleukin-1β and plasminogen-activator-inhibitor-1. Culture media conditioned by hMFs promoted cardiomyocyte hypertrophy, an effect that was prevented by neu-AbHi-FGF-2 in vitro. In conclusion, we have documented that Hi-FGF-2 represents a substantial fraction of FGF-2 in human cardiac (atrial) tissue and in pericardial fluid, and have shown that human Hi-FGF-2, unlike Lo-FGF-2, promotes deleterious (pro-fibrotic, pro-inflammatory, and pro-hypertrophic) responses in vitro. Selective targeting of Hi-FGF-2 production may, therefore, reduce pathological remodelling in the human heart.

  6. Rhodiola Inhibits Atrial Arrhythmogenesis in a Heart Failure Model.

    PubMed

    Liu, Shuen-Hsin; Hsiao, Ya-Wen; Chong, Eric; Singhal, Rahul; Fong, Man-Cai; Tsai, Yung-Nan; Hsu, Chiao-Po; Chen, Yao-Chang; Chen, Yi-Jen; Chiou, Chuen-Wang; Chiang, Shuo-Ju; Chang, Shih-Lin; Chen, Shih-Ann

    2016-09-01

    Rhodiola, a popular plant in Tibet, has been proven to decrease arrhythmia. The aim of this study was to elucidate the molecular mechanism and electrophysiological properties of rhodiola in the suppression of atrial fibrillation. This study consisted of 3 groups as follows: Group 1: normal control rabbits (n = 5); Group 2: rabbits with heart failure (HF) created by coronary ligation and who received 2 weeks of water orally as a placebo (n = 5); and Group 3: rabbits with HF who received 2 weeks of a rhodiola 270 mg/kg/day treatment orally (n = 5). The monophasic action potential, histology, and real-time polymerase chain reaction (RT-PCR) analysis of ionic channels and PI3K/AKT/eNOS were examined. Compared with the HF group, attenuated atrial fibrosis (35.4 ± 17.4% vs. 16.9 ± 8.4%, P = 0.05) and improved left ventricular (LV) ejection fraction (51.6 ± 3.4% vs. 68.0 ± 0.5%, P = 0.001) were observed in the rhodiola group. The rhodiola group had a shorter ERP (85.3 ± 6.8 vs. 94.3 ± 1.2, P = 0.002), APD90 (89.3 ± 1.5 vs. 112.7 ± 0.7, P < 0.001) in the left atrium (LA), and decreased AF inducibility (0.90 ± 0.04 vs. 0.42 ± 0.04, P < 0.001) compared with the HF group. The mRNA expressions of Kv1.4, Kv1.5, Kv4.3, KvLQT1, Cav1.2, and SERCA2a in the HF LA were up-regulated after rhodiola treatment. The rhodiola-treated HF LA demonstrated higher mRNA expression of PI3K-AKT compared with the HF group. Rhodiola reversed LA electrical remodeling, attenuated atrial fibrosis and suppressed AF in rabbits with HF. The beneficial electrophysiological effect of rhodiola may be related to upregulation of Kv1.4, Kv1.5, Kv4.3, KvLQT1, Cav1.2, SERCA2a, and activation of PI3K/AKT signaling. © 2016 Wiley Periodicals, Inc.

  7. Cerebral Pulsatility Index Is Elevated in Patients with Elevated Right Atrial Pressure.

    PubMed

    Lahiri, Shouri; Schlick, Konrad H; Padrick, Matthew M; Rinsky, Brenda; Gonzalez, Nestor; Jones, Heather; Mayer, Stephan A; Lyden, Patrick D

    2018-01-01

    Extracerebral venous congestion can precipitate intracranial hypertension due to obstruction of cerebral blood outflow. Conditions that increase right atrial pressure, such as hypervolemia, are thought to increase resistance to jugular venous outflow and contribute to cerebro-venous congestion. Cerebral pulsatility index (CPI) is considered a surrogate marker of distal cerebrovascular resistance and is elevated with intracranial hypertension. Thus, we sought to test the hypothesis that elevated right atrial pressure is associated with increased CPI compared to normal right atrial pressure. We retrospectively reviewed 61 consecutive patients with subarachnoid hemorrhage. We calculated CPI from transcranial Doppler studies and correlated these with echocardiographic measures of right atrial pressure. CPIs were compared from patients with elevated and normal right atrial pressure. There was a significant difference between CPI obtained from all patients with elevated right atrial pressure compared to those with normal right atrial pressure (P < .0001). This finding was consistent in sensitivity analysis that compared right and left hemispheric CPI from patients with both elevated and normal right atrial pressure. Patients with elevated right atrial pressure had significantly higher CPI compared to patients with normal right atrial pressure. These findings suggest that cerebro-venous congestion due to impaired jugular venous outflow may increase distal cerebrovascular resistance as measured by CPI. Since elevated CPI is associated with poor outcome in numerous neurological conditions, future studies are needed to elucidate the significance of these results in other populations. Copyright © 2017 by the American Society of Neuroimaging.

  8. Atrial contribution to ventricular filling in mitral stenosis.

    PubMed

    Meisner, J S; Keren, G; Pajaro, O E; Mani, A; Strom, J A; Frater, R W; Laniado, S; Yellin, E L

    1991-10-01

    The importance of the contribution of atrial systole to ventricular filling in mitral stenosis is controversial. The cause of reduced cardiac output following the onset of atrial fibrillation may be due to an increased heart rate, a loss of booster pump function, or both. We studied the atrial contribution to filling under a variety of conditions by combining noninvasive studies of patients with computer modeling. Thirty patients in sinus rhythm with mild-to-severe stenosis were studied with two-dimensional and Doppler echocardiography for measurement of mitral flow velocity and mitral valve area (MVA). The mean +/- SD atrial contribution to left ventricular filling volume was 18 +/- 10% and varied inversely with mitral resistance. Patients with mild mitral stenosis (MVA, 1.8 +/- 0.7 cm2) and severe mitral stenosis (MVA, 0.9 +/- 0.2 cm2) had atrial contributions of 29 +/- 4% and 9 +/- 5%, respectively. The pathophysiological mechanisms responsible for these trends were further investigated by the computer model. In modeled severe mitral stenosis, increasing heart rate from 75 to 150 beats/min caused an increase of 5.2 mm Hg in mean left atrial pressure, whereas loss of atrial contraction at a heart rate of 150 beats/min caused only a 1.3 mm Hg increase. The atrial booster pump contributes less to ventricular filling in mitral stenosis than in the normal heart, and the loss of atrial pump function is less important than the effect of increasing heart rate as the cause of decompensation during atrial fibrillation.

  9. 'What else can I do?': Insights from atrial fibrillation patient communication online.

    PubMed

    Redman, Kirsten; Thorne, Sally; Lauck, Sandra B; Taverner, Tarnia

    2017-03-01

    Many patients with atrial fibrillation experience uncertainty and psychological distress. Internet support groups for atrial fibrillation have yet to be studied. To determine the content and dialogue on an online message board for atrial fibrillation with the purpose of elucidating information and support needs from patient perspectives. Interpretative description methodology was undertaken to explore conversation from a publicly available website for atrial fibrillation over a 3-month period. Individuals interacted with the message board to make sense of their atrial fibrillation events by sharing experiences with medications, complementary and alternative medicine, trigger avoidance and ablation. The opinions of lay experts on the message board, anecdotal stories and hyperlinked Internet data were all highly valued sources of information in the messages. Using the learning gained from the board, individuals proceeded with strategies to treat their atrial fibrillation, often in a trial and error fashion. Throughout the process, individuals came back to the board, to update on their progress and gain assistance from others. The studied atrial fibrillation population had unmet needs for education regarding non-pharmacological approaches to treat atrial fibrillation. In the absence of opportunity to discuss these needs with healthcare professionals, patients may be vulnerable to unproved approaches advocated by Internet peers. Further research is suggested to examine the prevalence of complementary and alternative medicine use in the atrial fibrillation population and to understand better how social media can be utilised to support atrial fibrillation patients.

  10. Atrial Fibrillation - Multiple Languages

    MedlinePlus

    ... Atrial Fibrillation - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section Atrial ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF ... Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section Atrial ...

  11. Left Atrial Enlargement in Young High-Level Endurance Athletes - Another Sign of Athlete's Heart?

    PubMed

    Król, Wojciech; Jędrzejewska, Ilona; Konopka, Marcin; Burkhard-Jagodzińska, Krystyna; Klusiewicz, Andrzej; Pokrywka, Andrzej; Chwalbińska, Jolanta; Sitkowski, Dariusz; Dłużniewski, Mirosław; Mamcarz, Artur; Braksator, Wojciech

    2016-12-01

    Enlargement of the left atrium is perceived as a part of athlete's heart syndrome, despite the lack of evidence. So far, left atrial size has not been assessed in the context of exercise capacity. The hypothesis of the present study was that LA enlargement in athletes was physiological and fitness-related condition. In addition, we tried to assess the feasibility and normal values of left atrial strain parameters and their relationship with other signs of athlete's heart. The study group consisted of 114 international-level rowers (17.5 ± 1.5 years old; 46.5% women). All participants underwent a cardio-pulmonary exercise test and resting transthoracic echocardiography. Beside standard echocardiographic measurements, two dimensional speckle tracking echocardiography was used to assess average peak atrial longitudinal strain, peak atrial contraction strain and early left atrial diastolic longitudinal strain. Mild, moderate and severe left atrial enlargement was present in 27.2°%, 11.4% and 4.4% athletes, respectively. There were no significant differences between subgroups with different range of left atrial enlargement in any of echocardiographic parameters of the left ventricle diastolic function, filling pressure or hypertrophy. A significant correlation was found between the left atrial volume index and maximal aerobic capacity (R > 0.3; p < 0.001). Left atrial strain parameters were independent of atrial size, left ventricle hypertrophy and left ventricle filling pressure. Decreased peak atrial longitudinal strain was observed in 4 individuals (3.5%). We concluded that LA enlargement was common in healthy, young athletes participating in endurance sport disciplines with a high level of static exertion and was strictly correlated with exercise capacity, therefore, could be perceived as another sign of athlete's heart.

  12. Gremlin 2 promotes differentiation of embryonic stem cells to atrial fate by activation of the JNK signaling pathway

    PubMed Central

    Tanwar, Vineeta; Bylund, Jeffery B.; Hu, Jianyong; Yan, Jingbo; Walthall, Joel M.; Mukherjee, Amrita; Heaton, William H.; Wang, Wen-Der; Potet, Franck; Rai, Meena; Kupershmidt, Sabina; Knapik, Ela W.; Hatzopoulos, Antonis K.

    2014-01-01

    The Bone Morphogenetic Protein antagonist Gremlin 2 (Grem2) is required for atrial differentiation and establishment of cardiac rhythm during embryonic development. A human Grem2 variant has been associated with familial atrial fibrillation, suggesting that abnormal Grem2 activity causes arrhythmias. However, it is not known how Grem2 integrates into signaling pathways to direct atrial cardiomyocyte differentiation. Here, we demonstrate that Grem2 expression is induced concurrently with the emergence of cardiovascular progenitor cells during differentiation of mouse embryonic (ES) stem cells. Grem2 exposure enhances the cardiogenic potential of ES cells by ~20–120 fold, preferentially inducing genes expressed in atrial myocytes such as Myl7, Nppa and Sarcolipin. We show that Grem2 acts upstream to upregulate pro-atrial transcriptional factors CoupTFII and Hey1 and downregulate atrial fate repressors Irx4 and Hey2. The molecular phenotype of Grem2-induced atrial cardiomyocytes was further supported by induction of ion channels encoded by Kcnj3, Kcnj5, and Cacna1D genes and establishment of atrial-like action potentials shown by electrophysiological recordings. We show that promotion of atrial-like cardiomyocyte is specific to the Gremlin subfamily of BMP antagonists. Grem2 pro-atrial differentiation activity is conveyed by non-canonical BMP signaling through phosphorylation of JNK and can be reversed by specific JNK inhibitors, but not by dorsomorphin, an inhibitor of canonical BMP signaling. Taken together, our data provide novel mechanistic insights into atrial cardiomyocyte differentiation from pluripotent stem cells and will assist the development of future approaches to study and treat arrhythmias. PMID:24648383

  13. The heart is a representation of life: an exploration of illness beliefs in couples living with atrial fibrillation.

    PubMed

    Dalteg, Tomas; Sandberg, Jonas; Malm, Dan; Sandgren, Anna; Benzein, Eva

    2017-11-01

    To explore illness beliefs in couples where one spouse has atrial fibrillation. Beliefs are the lenses through which we view the world, guiding our behaviour and constructing our lives. Couples evolve an ecology of beliefs from their interaction whereby their actions and choices arise from their beliefs. Atrial fibrillation is a common cardiac arrhythmia that has implications for both patients and partners. A couple's illness beliefs play an important role in convalescence and illness management, and no previous studies have explored illness beliefs in couples living with atrial fibrillation. A qualitative hermeneutic design. Data collection constituted in-depth interviews with nine couples (patient and partner together). Hermeneutic philosophy as described by Gadamer was used to interpret and to understand illness beliefs in couples living with atrial fibrillation. The findings revealed both core illness beliefs and secondary illness beliefs. From the core illness belief 'The heart is a representation of life', two secondary illness beliefs were derived: atrial fibrillation is a threat to life and atrial fibrillation can and must be explained. From the core illness belief 'Change is an integral part of life', two secondary illness beliefs were derived: atrial fibrillation is a disruption in our lives and atrial fibrillation will not interfere with our lives. Finally, from the core illness belief 'Adaptation is fundamental in life', two secondary illness beliefs were derived: atrial fibrillation entails adjustment in daily life and atrial fibrillation entails confidence in and adherence to professional care. Couples' interaction has developed mutual illness beliefs regarding atrial fibrillation that guide them in their daily lives and influence their decisions. The adoption of a family-centred perspective in cardiovascular care settings is warranted. © 2017 John Wiley & Sons Ltd.

  14. Primary prevention of atrial fibrillation: does the atrial lead position influence the incidence of atrial arrhythmias in patients with sinus node dysfunction? Results from the PASTA Trial.

    PubMed

    Spitzer, Stefan G; Wacker, Petra; Gazarek, Steffen; Malinowski, Klaus; Schibgilla, Volker

    2009-12-01

    PASTA (pacing of the atria in sinus node disease) is a prospective and randomized trial, assessing the effect of different atrial lead positions on the atrial fibrillation (AF) incidence in patients with sinus node disease (SND). The atrial lead position is randomized to: (a) free right atrial wall, (b) right atrial appendage (RAA), (c) coronary sinus ostium (CS-Os), or (d) dual site right atrial pacing (CS-Os + RAA). The pacemakers (Vitatron Selection 9000 or Prevent AF, Vitatron B.V., Arnhem, The Netherlands) are programmed in DDDR 70 mode and the total follow-up duration is 24 months. To describe the atrial rhythm state, pacemaker-derived data (arrhythmia counter) were assessed for AF episodes. AF was considered as evident, if the AF burden (time in AF related to follow-up interval) was >1% (i.e., 15 min/d). Follow-up data after 24 months were evaluated. The analysis evaluates 142 patients (77 male, 74.5 +/- 7.8 years). There was no statistical significant difference with respect to the occurrence of AF between the four groups after 24 months (A: 36%; B: 38%, C: 32%, D: 48%). The percentage of atrial/ventricular pacing was in A: 78/76%, in B: 84/81%, in C: 70/65%, and in D: 79/69%. These differences were not significant. The evaluation of the AF burden >1% and the total AF burden after 24 months did not show differences in the incidence of AF in patients with dual chamber pacemaker therapy for SND. We were not able to demonstrate a significant influence of right atrial lead position on the incidence of AF recurrence.

  15. [Evaluation of the quality control of anticoagulation in patients with atrial fibrillation in a Primary Health Care Area of Madrid].

    PubMed

    Habashneh Sánchez, S; Abad Díaz, I; Tinajero Valle, C P; Cortés Palmero, A; Lobón Agúndez, M C; Muñoz Fernández, C

    2016-01-01

    To calculate the time in therapeutic range (TTR), as well as the scores on the CHADS2 scale in anticoagulated patients with non-valvular atrial fibrillation, attending the Primary Care Health Centre of Aravaca. Basic health area of Aravaca (Madrid). Retrospective observational study. The Community of Madrid provides a list of patients with non-valvular atrial fibrillation and on anticoagulant therapy in the centre. Excluding those with less than 8 INRs, who began treatment after January 2011, interrupted by inter-current treatment or had cancer or coagulopathy. The study period is from 1 January 2012 to 1 January 2013. The TTR (fraction of INRs in range) was the primary endpoint. The score was also calculated on the CHADS2 scale. A value of 56.28% TTR (59.5-53.1) was obtained from a sample of 963 INRs. Just over half (52%) of patients had a TTR<60%. There were 65 patients with a mean age of 80±7.5 years. The distribution of risk factors for the CHADS2 scale was: Heart failure 18.5%; hypertension 80%; diabetes 29.2%, and embolic events 18.5%. The results of our sample TTR is suboptimal (<60%), which implies an increased risk for embolic episodes and increased likelihood of bleeding. We need to incorporate into our clinical practice an objective measure of the quality of anticoagulation in order to identify poorly controlled patients and introduce corrective measures. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  16. 3 Tesla MRI-detected brain lesions after pulmonary vein isolation for atrial fibrillation: results of the MACPAF study.

    PubMed

    Haeusler, Karl Georg; Koch, Lydia; Herm, Juliane; Kopp, Ute A; Heuschmann, Peter U; Endres, Matthias; Schultheiss, Heinz-Peter; Schirdewan, Alexander; Fiebach, Jochen B

    2013-01-01

    Left atrial catheter ablation (LACA) is an established therapeutic approach to abolish symptomatic atrial fibrillation (AF). Based on the prospective MACPAF study (clinicaltrials.gov NCT01061931) we report the rate of ischemic brain lesions postablation and their impact on cognitive function. Patients with symptomatic paroxysmal AF were randomized to LACA using the Arctic Front® or the HD Mesh Ablator® catheter. All patients underwent brain MRI at 3 Tesla, neurological, and neuropsychological examinations within 48 hours prior and after the ablation procedure. There was no clinically evident stroke in 37 patients (mean age 62.4 ± 8.4 years; 41% female; median CHADS2 score 1 [IQR 0-2]) after LACA but high-resolution diffusion-weighted imaging (DWI) detected new ischemic lesions in 15 (41%) patients after LACA. Four (27%) of the HD Mesh Ablator® patients and 11 (50%) of the Arctic Front® patients suffered a silent ischemic lesion (P = 0.19). In these 15 patients, there was a nonsignificant trend toward lower cardiac ejection fraction (P = 0.07) and AF episodes during LACA (P = 0.09), while activated clotting time levels, number of energy applications, periprocedural electrocardioversion or CHADS(2) score had no impact. Lesion volumes varied from 5 to 150 mm(3) and 1 to 5 lesions were detected per patient. However, acute brain lesions had no effect on cognitive performance immediately after LACA. Of the DWI lesions postablation 82% were not detectable on FLAIR images 6-9 months postablation. According to 3 Tesla high-resolution DWI, ischemic brain lesions after LACA were common but not associated with impaired cognitive function after the ablation procedure. © 2012 Wiley Periodicals, Inc.

  17. Prognostic implications of atrial fibrillation in patients undergoing myocardial perfusion single-photon emission computed tomography.

    PubMed

    Abidov, Aiden; Hachamovitch, Rory; Rozanski, Alan; Hayes, Sean W; Santos, Marcia M; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Friedman, John D; Germano, Guido; Berman, Daniel S

    2004-09-01

    The aim of this research was to determine whether presence of atrial fibrillation (AF) provides incremental prognostic information relative to myocardial perfusion single-photon emission computed tomography (MPS) with respect to risk of cardiac death (CD). The prognostic significance of AF in patients undergoing MPS is not known. A total of 16,048 consecutive patients undergoing MPS were followed-up for a mean of 2.21 +/- 1.15 years for the development of CD. Of those, 384 patients (2.4%) had AF. Cox proportional hazards method was used to compare clinical and perfusion data for the prediction of CD in patients with and without AF. Atrial fibrillation was a significant predictor of CD in patients with normal (1.6% per year vs. 0.4% per year in non-AF patients), mildly abnormal (6.3% per year vs. 1.2% per year), and severely abnormal MPS (6.4% per year vs. 3.7% per year) (p < 0.001 for all). By multivariable analysis, AF patients had worse survival (p = 0.001) even after adjustment for the variables most predictive of CD: age, diabetes, shortness of breath, use of vasodilator stress, rest heart rate, and the nuclear variables. In the 4,239 patients with left ventricular ejection fraction evaluated by gated MPS, AF demonstrated incremental prognostic value not only over clinical and nuclear variables, but also over left ventricular ejection in predicting CD (p = 0.014). The presence of AF independently increases the risk of cardiac events over perfusion and function variables in patients undergoing MPS. Patients with AF have a high risk of CD, even when MPS is only mildly abnormal. Whether patients with AF and mildly abnormal MPS constitute a group more deserving of early referral to cardiac catheterization is a question warranting further study.

  18. Is rhythm-control superior to rate-control in patients with atrial fibrillation and diastolic heart failure?

    PubMed

    Kong, Melissa H; Shaw, Linda K; O'Connor, Christopher; Califf, Robert M; Blazing, Michael A; Al-Khatib, Sana M

    2010-07-01

    Although no clinical trial data exist on the optimal management of atrial fibrillation (AF) in patients with diastolic heart failure, it has been hypothesized that rhythm-control is more advantageous than rate-control due to the dependence of these patients' left ventricular filling on atrial contraction. We aimed to determine whether patients with AF and heart failure with preserved ejection fraction (EF) survive longer with rhythm versus rate-control strategy. The Duke Cardiovascular Disease Database was queried to identify patients with EF > 50%, heart failure symptoms and AF between January 1,1995 and June 30, 2005. We compared baseline characteristics and survival of patients managed with rate- versus rhythm-control strategies. Using a 60-day landmark view, Kaplan-Meier curves were generated and results were adjusted for baseline differences using Cox proportional hazards modeling. Three hundred eighty-two patients met the inclusion criteria (285 treated with rate-control and 97 treated with rhythm-control). The 1-, 3-, and 5-year survival rates were 93.2%, 69.3%, and 56.8%, respectively in rate-controlled patients and 94.8%, 78.0%, and 59.9%, respectively in rhythm-controlled patients (P > 0.10). After adjustments for baseline differences, no significant difference in mortality was detected (hazard ratio for rhythm-control vs rate-control = 0.696, 95% CI 0.453-1.07, P = 0.098). Based on our observational data, rhythm-control seems to offer no survival advantage over rate-control in patients with heart failure and preserved EF. Randomized clinical trials are needed to verify these findings and examine the effect of each strategy on stroke risk, heart failure decompensation, and quality of life.

  19. Clinical predictors of cardiac magnetic resonance late gadolinium enhancement in patients with atrial fibrillation.

    PubMed

    Chrispin, Jonathan; Ipek, Esra Gucuk; Habibi, Mohammadali; Yang, Eunice; Spragg, David; Marine, Joseph E; Ashikaga, Hiroshi; Rickard, John; Berger, Ronald D; Zimmerman, Stefan L; Calkins, Hugh; Nazarian, Saman

    2017-03-01

    This study aims to examine the association of clinical co-morbidities with the presence of left atrial (LA) late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR). Previous studies have established the severity of LA LGE to be associated with atrial fibrillation (AF) recurrence following AF ablation. We sought to determine whether baseline clinical characteristics were associated with LGE extent among patients presenting for an initial AF ablation. The cohort consisted of 179 consecutive patients with no prior cardiac ablation procedures who underwent pre-procedure LGE-CMR. The extent of LA LGE for each patient was calculated using the image intensity ratio, normalized to the mean blood pool intensity, corresponding to a bipolar voltage ≤0.3 mV. The association of LGE extent with baseline clinical characteristics was examined using non-parametric and multivariable models. The mean age of the cohort was 60.9 ± 9.6 years and 128 (72%) were male. In total, 56 (31%) patients had persistent AF. The mean LA volume was 118.4 ± 41.6 mL, and the mean LA LGE extent was 14.1 ± 10.4%. There was no association with any clinical variables with LGE extent by quartiles in the multivariable model. Extent of LGE as a continuous variable was positively, but weakly associated with LA volume in a multivariable model adjusting for age, body mass index, AF persistence, and left ventricular ejection fraction (1.5% scar/mL, P = 0.038). In a cohort of patients presenting for initial AF ablation, the presence of pre-ablation LA LGE extent was weakly, but positively associated with increasing LA volume. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  20. Differential regulation of protein phosphatase 1 (PP1) isoforms in human heart failure and atrial fibrillation.

    PubMed

    Meyer-Roxlau, Stefanie; Lämmle, Simon; Opitz, Annett; Künzel, Stephan; Joos, Julius P; Neef, Stefan; Sekeres, Karolina; Sossalla, Samuel; Schöndube, Friedrich; Alexiou, Konstantin; Maier, Lars S; Dobrev, Dobromir; Guan, Kaomei; Weber, Silvio; El-Armouche, Ali

    2017-07-01

    Protein phosphatase 1 (PP1) is a key regulator of important cardiac signaling pathways. Dysregulation of PP1 has been heavily implicated in cardiac dysfunctions. Accordingly, pharmacological targeting of PP1 activity is considered for therapeutic intervention in human cardiomyopathies. Recent evidence from animal models implicated previously unrecognized, isoform-specific activities of PP1 in the healthy and diseased heart. Therefore, this study examined the expression of the distinct PP1 isoforms PP1α, β, and γ in human heart failure (HF) and atrial fibrillation (AF) and addressed the consequences of β-adrenoceptor blocker (beta-blocker) therapy for HF patients with reduced ejection fraction on PP1 isoform expression. Using western blot analysis, we found greater abundance of PP1 isoforms α and γ but unaltered PP1β levels in left ventricular myocardial tissues from HF patients as compared to non-failing controls. However, expression of all three PP1 isoforms was higher in atrial appendages from patients with AF compared to patients with sinus rhythm. Moreover, we found that in human failing ventricles, beta-blocker therapy was associated with lower PP1α abundance and activity, as indicated by higher phosphorylation of the PP1α-specific substrate eIF2α. Greater eIF2α phosphorylation is a known repressor of protein translation, and accordingly, we found lower levels of the endoplasmic reticulum (ER) stress marker Grp78 in the very same samples. We propose that isoform-specific targeting of PP1α activity may be a novel and innovative therapeutic strategy for the treatment of human cardiac diseases by reducing ER stress conditions.

  1. Conventional versus 3-D Echocardiography to Predict Arrhythmia Recurrence After Atrial Fibrillation Ablation.

    PubMed

    Bossard, Matthias; Knecht, Sven; Aeschbacher, Stefanie; Buechel, Ronny R; Hochgruber, Thomas; Zimmermann, Andreas J; Kessel-Schaefer, Arnheid; Stephan, Frank-Peter; Völlmin, Gian; Pradella, Maurice; Sticherling, Christian; Osswald, Stefan; Kaufmann, Beat A; Conen, David; Kühne, Michael

    2017-06-01

    Arrhythmia recurrence after atrial fibrillation (AF) ablation remains high and requires repeat interventions in a substantial number of patients. We assessed the value of conventional and 3-D echocardiography to predict AF recurrence. Consecutive patients undergoing AF ablation by means of pulmonary vein isolation were included in a prospective registry. Echocardiograms were obtained prior to the ablation procedure, and analyzed offline in a standardized manner, including 3-D left atrial (LA) volumetry and determination of LA function and sphericity. The primary endpoint, AF recurrence (>30 seconds) between 3 to 12 months after AF ablation, was independently adjudicated. We included 276 patients (73% male, mean age 59.9 ± 9.9 years). Paroxysmal and persistent AF were present in 178 (64%) and 98 (36%) patients, respectively. Mean left ventricular ejection fraction and indexed LA volume in 3-D (LAVI) were 52 ± 12% and 42 ± 13 mL/m 2 , respectively. AF recurrence was observed in 110 (40%) patients after a single procedure. Median (interquartile range) time to AF recurrence was 123 (92; 236) days. In multivariable Cox regression models, the only predictors for AF recurrence were the minimal, maximal, and indexed 3-D LA volumes, P = 0.024, P = 0.016, and P = 0.014, respectively. Quartile specific analysis of 3-D LAVI showed an HR of 1.885 (95%CI 1.066-3.334; P for trend = 0.015) for the highest compared to the lowest quartile. Our results show the important role of LA volume for the long-term freedom from arrhythmia after AF ablation. These data also highlight the potential of 3-D echocardiography in this context and may facilitate patient selection for AF ablation. © 2017 Wiley Periodicals, Inc.

  2. Association of cardiac cachexia and atrial fibrillation in heart failure patients.

    PubMed

    Arámbula-Garza, Estefanía; Castillo-Martínez, Lilia; González-Islas, Dulce; Orea-Tejeda, Arturo; Santellano-Juárez, Brenda; Keirns-Davies, Candace; Peláez-Hernández, Viridiana; Sánchez-Santillán, Rocío; Pineda-Juárez, Juan; Cintora-Martínez, Carlos; Pablo-Santiago, Ruth

    2016-11-15

    Cachexia is a common complication in patients with advanced heart failure (HF) associated with inflammatory response activation. Atrial fibrillation (AF) is the most frequent arrhythmia (26%), probably both exacerbate the cardiac cachexia (CC). Evaluate the association of cardiac cachexia and atrial fibrillation in heart failure patients. In a case control study, CC was diagnosed by electrical bioimpedance with vectorial analysis (BIVA). Subjects with congenital heart disease, cancer, HIV, drug use and other causes than HF were excluded. Of the 359 subjects analyzed (men: 52.9%) median age 65years (55-74). Those with CC were older [72 (61-67)] vs. without [62 (52-70) years old, p<0.01]. During follow-up 47.8% of subjects developed CC and 17.27% AF, this was significantly more frequent in cachectic patients CC (23% vs 12.11%, OR: 2.17, 95% CI: 1.19-4.01, p=0.006). Subjects, with AF had lower left ventricular ejection fraction (25.49±12.96 vs. 32.01±15.02, p=0.08), lower posterior wall thickness (10.03±2.12 vs. 11.00±2.47, p=0.007), larger diameter of the left atrium (49.87±9.84 vs. 42.66±7.56, p<0.001), and a higher prevalence of CC (85.42% vs. 69.77%, p=0.028). The 50.58% of was in NYHA class I. In NYHA III, 22.95% were in AF vs. 12.10% with not AF (p=0.027). The frequent coexistence of CC and AF as HF complications indicate greater severity of HF, regardless of its type of HF. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Atrial natriuretic peptide ameliorates hypoxic pulmonary vasoconstriction without influencing systemic circulation.

    PubMed

    Höhne, C; Drzimalla, M; Krebs, M O; Boemke, W; Kaczmarczyk, G

    2003-12-01

    Hypoxic pulmonary vasoconstriction (HPV) is encountered during ascent to high altitude. Atrial natriuretic peptide (ANP) could be an option to treat HPV because of its natriuretic, diuretic, and vasodilatory properties. Data on effects of ANP on pulmonary and systemic circulation during HVP are conflicting, partly owing to anesthesia, surgical stress or uncontrolled dietary conditions. Therefore, ten conscious, chronically tracheotomized dogs were studied under standardized dietary conditions. The dogs were trained to breathe spontaneously at a ventilator circuit. 30min of normoxia [inspiratory oxygen fraction (F(i)O(2))=0.21] were followed by 30min of hypoxia without ANP infusion (Hypoxia I, F(i)O(2)=0.1). While maintaining hypoxia an intravenous infusion of atrial natriuretic peptide was started with 50ng x kg body wt(-1) x min(-1) for 30min (Hypoxia+ANP1=low dose), followed by 1000ng x kg body wt(-1) x min(-1) for 30min (Hypoxia+ANP2=high dose). Thereafter, ANP infusion was stopped and hypoxia maintained for a final 30min (Hypoxia II). Compared to normoxia, mean pulmonary arterial pressure (MPAP) (16+/-0.7 vs. 26+/-1.3mmHg) and pulmonary vascular resistance (PVR) (448+/-28 vs. 764+/-89dyn x s(-1) x cm(-5)) increased during Hypoxia I and decreased during Hypoxia+ANP 1 (MPAP 20+/-1mmHg, PVR 542+/-55dyn x s(-1) x cm(-5)) (P<0.05). The higher dose of ANP did not further decrease MPAP or PVR, but started to have a tendency to decrease mean arterial pressure and cardiac output. We conclude that low dose ANP is able to reduce HPV without affecting systemic circulation during acute hypoxia.

  4. Extreme variation in the atrial septation of caecilians (Amphibia: Gymnophiona)

    PubMed Central

    de Bakker, Desiderius M; Wilkinson, Mark; Jensen, Bjarke

    2015-01-01

    Caecilians (order Gymnophiona) are elongate, limbless, snake-like amphibians that are the sister-group (closest relatives) of all other recent amphibians (frogs and salamanders). Little is known of their cardiovascular anatomy and physiology, but one nearly century old study suggests that Hypogeophis (family Indotyphlidae), commonly relied upon as a representative caecilian species, has atrial septation in the frontal plane and more than one septum. In contrast, in other vertebrates there generally is one atrial septum in the sagittal plane. We studied the adult heart of Idiocranium (also Indotyphlidae) using immunohistochemistry and confirm that the interatrial septum is close to the frontal plane. Additionally, a parallel right atrial septum divides three-fourths of the right atrial cavity of this species. Idiocranium embryos in the Hill collection reveal that atrial septation initiates in the sagittal plane as in other tetrapods. Late developmental stages, however, see a left-ward shift of visceral organs and a concordant rotation of the atria that reorients the atrial septa towards the frontal plane. The gross anatomies of species from six other caecilian families reveal that (i) the right atrial septum developed early in caecilian evolution (only absent in Rhinatrematidae) and that (ii) rotation of the atria evolved later and its degree varies between families. In most vertebrates a prominent atrial trabeculation associates with the sinuatrial valve, the so-called septum spurium, and the right atrial septum seems homologous to this trabeculation but much more developed. The right atrial septum does not appear to be a consequence of body elongation because it is absent in some caecilians and in snakes. The interatrial septum of caecilians shares multiple characters with the atrial septum of lungfishes, salamanders and the embryonic septum primum of amniotes. In conclusion, atrial septation in caecilians is based on evolutionarily conserved structures but possibly exhibits greater variation than in any other vertebrate order. PMID:25400089

  5. Fifty-Year Trends in Atrial Fibrillation Prevalence, Incidence, Risk Factors, and Mortality in the Community

    PubMed Central

    Schnabel, Renate B.; Yin, Xiaoyan; PhilimonGona; Larson, Martin G.; Beiser, Alexa S.; McManus, David D.; Newton-Cheh, Christopher; Lubitz, Steven A.; Magnani, Jared W.; Ellinor, Patrick T.; SudhaSeshadri; Wolf, Philip A; Vasan, Ramachandran S.; Benjamin, Emelia J.; Levy, Daniel

    2015-01-01

    Summary Background Comprehensive long-term data on atrial fibrillation trends in men and women are scant. Methods We investigated trends in atrial fibrillation incidence, prevalence, and risk factors, and in stroke and mortality following its onset in Framingham Heart Study participants (n=9511) from 1958 to 2007. To accommodate sex differences in atrial fibrillation risk factors and disease manifestations, sex-stratified analyses were performed. Findings During 50 years of observation (202,417 person-years), there were 1,544 new-onset atrial fibrillation cases (46.8% women). We observed about a fourfold increase in the age-adjusted prevalence and more than a tripling in age-adjusted incidence of atrial fibrillation (prevalence 20.4 versus 96.2 per 1000 person-years in men; 13.7 versus 49.4 in women; incidence rates in first versus last decade 3.7 versus 13.4 per 1000 person-years in men; 2.5 versus 8.6 in women, ptrend<0.0001). For atrial fibrillation diagnosed by ECG during routine Framingham examinations, age-adjusted prevalence increased (12.6versus 25.7 per 1000 person-years in men; 8.1 versus 11.8 in women, ptrend<0.0001). The age-adjusted incidence increased, but did not achieve statistical significance. Although the prevalence of most risk factors changed over time, their associated hazards for atrial fibrillation changed little. Multivariable-adjusted proportional hazards models revealed a 73.5% decline in stroke and a 25.4% decline in mortality following atrial fibrillation onset (ptrend=0.0001, ptrend=0.003, respectively). Interpretation Our data suggest that observed trends of increased incidence of atrial fibrillation in the community were partially due to enhanced surveillance. Stroke occurrence and mortality following atrial fibrillation onset declined over the decades, and prevalence increased approximately fourfold. The hazards for atrial fibrillation risk factors remained fairly constant. Our data indicate a need for measures to enhance early detection of atrial fibrillation through increased awareness coupled with targeted screening programs, and risk factor-specific prevention. PMID:25960110

  6. Early cardioversion of atrial fibrillation and atrial flutter guided by transoesophageal echocardiography: a single centre 8.5-year experience.

    PubMed

    Corrado, G; Santarone, M; Beretta, S; Tadeo, G; Tagliagambe, L M; Foglia-Manzillo, G; Spata, M; Miglierina, E; Acquati, F; Santarone, M

    2000-04-01

    To analyse the safety and impact on maintenance of sinus rhythm of transoesophageal echocardiographically guided early cardioversion associated with short-term anticoagulation in a large series of patients with atrial fibrillation and atrial flutter. Patients who were candidates for cardioversion were eligible for inclusion if they had atrial fibrillation or atrial flutter lasting longer than 2 days or of unknown duration. Patients received short-term anticoagulation with warfarin or heparin and underwent transthoracic echocardiography followed by transoesophageal echocardiography. Early cardioversion was performed if no thrombus was seen on the transoesophageal study. Warfarin was maintained for 1 month after cardioversion. In patients with atrial thrombi, cardioversion was deferred and prolonged anticoagulation was prescribed. The study population included 183 patients. One hundred and sixty nine patients without atrial thrombi underwent early cardioversion. Fourteen patients with atrial thrombi (7.6%) underwent a second transoesophageal echocardiogram after a median of 4 weeks of oral warfarin, and cardioversion was performed if clot regression was documented. No patient in our study population had a clinical thromboembolic event at 1 month follow-up (95% C.I. 0-0.016). The immediate success rate of cardioversion was better among patients with atrial fibrillation < 4 weeks duration compared with patients with atrial fibrillation of longer or of unknown duration: 96.6% vs 85%, respectively (P = 0.014). At 1 month follow-up, the percentage of arrhythmia relapses in patients with initially successful cardioversion was similar in the two groups (29% vs 26%, P = ns); thus the initial better outcome in patients with recent-onset arrhythmia was not lost. Transoesophageal echocardiography-guided early cardioversion in concert with short-term anticoagulation is safe. This approach permits abbreviation of the overall duration of atrial fibrillation and has a better impact on the maintenance of sinus rhythm for patients in whom the duration of atrial fibrillation is < 4 weeks.

  7. Heterogeneity of transverse-axial tubule system in mouse atria: Remodeling in atrial-specific Na+-Ca2+ exchanger knockout mice.

    PubMed

    Yue, Xin; Zhang, Rui; Kim, Brian; Ma, Aiqun; Philipson, Kenneth D; Goldhaber, Joshua I

    2017-07-01

    Transverse-axial tubules (TATs) are commonly assumed to be sparse or absent in atrial myocytes from small animals. Atrial myocytes from rats, cats and rabbits lack TATs, which results in a characteristic "V"-shaped Ca release pattern in confocal line-scan recordings due to the delayed rise of Ca in the center of the cell. To examine TAT expression in isolated mouse atrial myocytes, we loaded them with the membrane dye Di-4-ANEPPS to label TATs. We found that >80% of atrial myocytes had identifiable TATs. Atria from male mice had a higher TAT density than female mice, and TAT density correlated with cell width. Using the fluorescent Ca indicator Fluo-4-AM and confocal imaging, we found that wild type (WT) mouse atrial myocytes generate near-synchronous Ca transients, in contrast to the "V"-shaped pattern typically reported in other small animals such as rat. In atrial-specific Na-Ca exchanger (NCX) knockout (KO) mice, which develop sinus node dysfunction and atrial hypertrophy with dilation, we found a substantial loss of atrial TATs in isolated atrial myocytes. There was a greater loss of transverse tubules compared to axial tubules, resulting in a dominance of axial tubules. Consistent with the overall loss of TATs, NCX KO atrial myocytes displayed a "V"-shaped Ca transient with slower and reduced central (CT) Ca release and uptake in comparison to subsarcolemmal (SS) Ca release. We compared chemically detubulated (DT) WT cells to KO, and found similar slowing of CT Ca release and uptake. However, SS Ca transients in the WT DT cells had faster uptake kinetics than KO cells, consistent with the presence of NCX and normal sarcolemmal Ca efflux in the WT DT cells. We conclude that the remodeling of NCX KO atrial myocytes is accompanied by a loss of TATs leading to abnormal Ca release and uptake that could impact atrial contractility and rhythm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Organized Atrial Tachycardias after Atrial Fibrillation Ablation

    PubMed Central

    Castrejón-Castrejón, Sergio; Ortega, Marta; Pérez-Silva, Armando; Doiny, David; Estrada, Alejandro; Filgueiras, David; López-Sendón, José L.; Merino, José L.

    2011-01-01

    The efficacy of catheter-based ablation techniques to treat atrial fibrillation is limited not only by recurrences of this arrhythmia but also, and not less importantly, by new-onset organized atrial tachycardias. The incidence of such tachycardias depends on the type and duration of the baseline atrial fibrillation and specially on the ablation technique which was used during the index procedure. It has been repeatedly reported that the more extensive the left atrial surface ablated, the higher the incidence of organized atrial tachycardias. The exact origin of the pathologic substrate of these trachycardias is not fully understood and may result from the interaction between preexistent regions with abnormal electrical properties and the new ones resultant from radiofrequency delivery. From a clinical point of view these atrial tachycardias tend to remit after a variable time but in some cases are responsible for significant symptoms. A precise knowledge of the most frequent types of these arrhythmias, of their mechanisms and components is necessary for a thorough electrophysiologic characterization if a new ablation procedure is required. PMID:21941669

  9. Atrial cardiopathy: a mechanism of cryptogenic stroke.

    PubMed

    Yaghi, Shadi; Kamel, Hooman; Elkind, Mitchell S V

    2017-08-01

    Cryptogenic stroke accounts for approximately 30% of all ischemic strokes. Recently, atrial cardiopathy diagnosed by the presence of one of its serum, imaging, or electrocardiogram biomarkers has been shown to be associated with ischemic stroke, particularly of embolic subtypes. Areas covered: This paper aims to summarize data on occult atrial fibrillation and stroke, provide an overview on mechanisms, such as inflammation and fibrosis, of stroke in atrial cardiopathy, critically review data on biomarkers of atrial cardiopathy and their association with stroke, and suggest therapeutic implications, including directions for future research. Expert commentary: Atrial cardiopathy may constitute one of the mechanisms in cryptogenic stroke, and patients with evidence of atrial cardiopathy constitute a group of patients in whom clinical trials are warranted to test anticoagulation versus antiplatelet therapy to reduce stroke recurrence risk. In addition, more studies are needed to determine the degree of overlap between these atrial cardiopathy biomarkers and which one is more useful in predicting the risk of stroke and response to anticoagulation therapy.

  10. Undersensing of VF in a patient with optimal R wave sensing during sinus rhythm.

    PubMed

    Dekker, Lukas R C; Schrama, Tim A M; Steinmetz, Frans H L; Tukkie, Raymond

    2004-06-01

    We describe a case of potentially fatal undersensing of VF by a third generation ICD with predetermined automatic gain control. In this patient, ventricular sensing was optimal, as R wave amplitudes during sinus rhythm were at least 16 mV. Cyclical, high amplitude signals during VF elevated the sensing floor to such an extent that complete undersensing of subsequent lower amplitude local electrograms occurred. This led to bradypacing and complete ICD therapy failure. Therefore, high R wave amplitudes during sinus rhythm do not warrant flawless sensing during VF.

  11. Left atrial size and function: role in prognosis.

    PubMed

    Hoit, Brian D

    2014-02-18

    The author examines the ability of left atrial size and function to predict cardiovascular outcomes. Data are sufficient to recommend evaluation of left atrial volume in certain populations, and although analysis of atrial reservoir, conduit, and booster pump function trails in that regard, the gap is rapidly closing. In this state-of-the-art paper, the author reviews the methods used to assess left atrial size and function and discusses their role in predicting cardiovascular events in general and referral populations and in patients with atrial fibrillation, cardiomyopathy, ischemic heart disease, and valvular heart disease. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Ambulatory ECG monitoring in atrial fibrillation management.

    PubMed

    Rosero, Spencer Z; Kutyifa, Valentina; Olshansky, Brian; Zareba, Wojciech

    2013-01-01

    Ambulatory ECG monitoring technology has rapidly evolved over the last few decades and has been shown to identify life-threatening and non-life threatening arrhythmias and provide actionable data to guide clinical decision making. Atrial fibrillation episodes can often be asymptomatic, even after catheter ablation for atrial fibrillation, creating a disconnect between symptoms and actual arrhythmia burden which may alter clinical management. In this review, we aim to provide a comprehensive overview of invasive and non-invasive ECG monitoring strategies in patients with atrial fibrillation, with a special focus on the diagnosis of atrial fibrillation, and on follow-up of patients after catheter ablation for atrial fibrillation ablation. © 2013.

  13. Survival after extreme left atrial hypertension and pulmonary hemorrhage in an infant supported with extracorporeal membrane oxygenation for refractory atrial flutter.

    PubMed

    Cisco, Michael J; Asija, Ritu; Dubin, Anne M; Perry, Stanton B; Hanley, Frank L; Roth, Stephen J

    2011-05-01

    We report here the survival of an infant who developed extreme left atrial hypertension and severe pulmonary hemorrhage while supported with extracorporeal membrane oxygenation for refractory atrial flutter. The patient recovered after decompression of the left heart and catheter ablation of the atrioventricular node. Lucile Packard Children's Hospital (Stanford, CA). Chart review. Recovery of lung function is possible despite systemic-level left atrial pressure resulting in pulmonary hemorrhage and complete solidification of lung parenchyma on gross inspection. Resolution of pulmonary hemorrhage despite anticoagulation while on extracorporeal membrane oxygenation can occur after relief of left atrial hypertension.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiao-Qing; Zhang, Dao-Liang; Zhang, Ming-Jian

    Aims: Atrial fibroblasts and macrophages have long been thought to participate in atrial fibrillation (AF). However, which specific mediator may regulate the interaction between them remains unclear. Methods and results: We provided the evidence for the involvement of Toll/IL-1 receptor domain-containing adaptor inducing IFN-β (TRIF), an important inflammation-related molecule, in the pathophysiology of AF. Patients with AF showed higher levels of angiotensin II (AngII) and TRIF expression and larger number of macrophages infiltration in left atria appendage than individuals with sinus rhythm (SR). In the cell study, AngII induced chemokines expressions in mouse atrial fibroblasts and AngII-stimulated atrial fibroblasts inducedmore » the chemotaxis of macrophages, which were reduced by losartan and TRIF siRNA. Meanwhile, AngII-stimulated atrial fibroblasts proliferation was enhanced by macrophages. Conclusions: Our data demonstrated that TRIF may be a crucial factor promoting the interaction between atrial fibroblasts and macrophages, leading to atrial fibrosis. - Highlights: • Compared with SR, AF showed higher TRIF expression in left atrial appendage. • TRIF siRNA reversed macrophage chemotaxis induced by AngII-treated fibroblast. • TRIF siRNA reversed chemokines expressions induced by AngII in fibroblast. • AngII-stimulated atrial fibroblast proliferation was enhanced by macrophage.« less

  15. Left Atrial Remodeling and Atrioventricular Coupling in a Canine Model of Early Heart Failure With Preserved Ejection Fraction

    PubMed Central

    Zakeri, Rosita; Moulay, Gilles; Chai, Qiang; Ogut, Ozgur; Hussain, Saad; Takahama, Hiroyuki; Lu, Tong; Wang, Xiao-Li; Linke, Wolfgang A.; Lee, Hon-Chi; Redfield, Margaret M.

    2016-01-01

    Background Left atrial (LA) compliance and contractility influence left ventricular (LV) stroke volume. We hypothesized that diminished LA compliance and contractile function occur early during development of heart failure with preserved ejection fraction (HFpEF) and impair overall cardiac performance. Method and Results Cardiac magnetic resonance imaging, echocardiography, LV and LA pressure-volume studies, and tissue analyses were performed in a model of early HFpEF (elderly dogs, renal wrap-induced hypertension, exogenous aldosterone; n=9) and young control dogs (sham surgery; n=13). Early HFpEF was associated with LA enlargement, cardiomyocyte hypertrophy and enhanced LA contractile function (median active emptying fraction 16% [95% CI 13–24] vs 12[10–14]%, p=0.008; end-systolic pressure-volume relationship slope 2.4[1.9–3.2]mmHg/mL HFpEF vs 1.5[1.2–2.2]mmHg/mL controls, p=0.01). However, atrioventricular coupling was impaired and the curvilinear LA end-reservoir pressure-volume relationship was shifted upward/leftward in HFpEF (LA stiffness constant, βLA, 0.16[0.11–0.18]mmHg/mL vs 0.06[0.04–0.10]mmHg/mL controls, p=0.002) indicating reduced LA compliance. Impaired atrioventricular coupling and lower LA compliance correlated with lower LV stroke volume. Total fibrosis and titin isoform composition were similar between groups, however titin was hyperphosphorylated in HFpEF and correlated with βLA. LA microvascular reactivity was diminished in HFpEF versus controls. LA microvascular density tended to be lower in HFpEF and inversely correlated with βLA. Conclusions In early-stage hypertensive HFpEF, LA cardiomyocyte hypertrophy, titin hyperphosphorylation and microvascular dysfunction occur in association with increased systolic and diastolic LA chamber stiffness, impaired atrioventricular coupling and decreased LV stroke volume. These data indicate that maladaptive LA remodeling occurs early during HFpEF development, supporting a concept of global myocardial remodeling. PMID:27758811

  16. Speckle tracking analysis: a new tool for left atrial function analysis in systemic hypertension: an overview.

    PubMed

    Cameli, Matteo; Ciccone, Marco M; Maiello, Maria; Modesti, Pietro A; Muiesan, Maria L; Scicchitano, Pietro; Novo, Salvatore; Palmiero, Pasquale; Saba, Pier S; Pedrinelli, Roberto

    2016-05-01

    Speckle tracking echocardiography (STE) is an imaging technique applied to the analysis of left atrial function. STE provides a non-Doppler, angle-independent and objective quantification of left atrial myocardial deformation. Data regarding feasibility, accuracy and clinical applications of left atrial strain are rapidly gathering. This review describes the fundamental concepts of left atrial STE, illustrates its pathophysiological background and discusses its emerging role in systemic arterial hypertension.

  17. Relation of Obesity to New-Onset Atrial Fibrillation and Atrial Flutter in Adults.

    PubMed

    Foy, Andrew J; Mandrola, John; Liu, Guodong; Naccarelli, Gerald V

    2018-05-01

    Prospective cohort studies involving older adults report an association of obesity and new-onset atrial fibrillation and atrial flutter. To assess this relation, we performed a longitudinal cohort study from January 1, 2006 to December 31, 2013, using a national claims database that tracks all inpatient, outpatient, and pharmacy claims data. The primary end point of new-onset atrial fibrillation was compared between obese and nonobese cohorts. We used logistic regression to determine the strength of association between obesity and new-onset atrial fibrillation controlling for age, gender, hypertension, and diabetes. Overall, 67,278 subjects were included in the cohort, divided evenly between those with and without a diagnosis of obesity. Obese subjects were significantly more likely to have hypertension (29.5% vs 14.6%) and diabetes (12.7% vs 5.2%) at study onset. Over 8 years of follow-up, we recorded a new diagnosis of atrial fibrillation in 1,511 (2.2%) subjects. Obesity was strongly associated with a new diagnosis of atrial fibrillation after controlling for age, gender, hypertension, and diabetes (odds ratio 1.4, 95% confidence interval 1.3 to 1.6). In conclusion, this information contributes to the growing evidence supporting the causal relation between obesity and atrial fibrillation, and emphasizes the need of addressing obesity as part of our therapeutic strategy to prevent atrial fibrillation. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Effects of novel oral anticoagulants on left atrial and left atrial appendage thrombi: an appraisal.

    PubMed

    Marsico, Fabio; Cecere, Milena; Parente, Antonio; Paolillo, Stefania; de Martino, Fabiana; Dellegrottaglie, Santo; Trimarco, Bruno; Perrone Filardi, Pasquale

    2017-02-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and predisposes to an increased risk of thromboembolic events. Patients affected by AF exhibit an increased risk of stroke compared with those in sinus rhythm, with the most common location of thrombi in the left atrial appendage. Until 2009, warfarin and other vitamin K antagonists were the only class of oral anticoagulants available. More recently, dabigatran, rivaroxaban, apixaban, and edoxaban have been approved by regulatory authorities for prevention of stroke in patients with non-valvular AF. Few data are available about the efficacy of novel oral anticoagulants for the treatment of left atrial and left atrial appendage thrombosis. Aim of this review is to summarize available evidence regarding the effectiveness of novel oral anticoagulants on left atrial appendage thrombosis.

  19. Low energy transvenous cardioversion of short duration atrial tachyarrhythmias in humans using a single lead system.

    PubMed

    Heisel, A; Jung, J; Fries, R; Stopp, M; Sen, S; Schieffer, H; Ozbek, C

    1997-01-01

    The purpose of this study was to investigate the efficacy and safety of atrial cardioversion using an endocardial single lead system presently used for ventricular defibrillation. The study population consisted of 26 recipients of an ICD in combination with a conventional endocardial single lead system with the proximal spring electrode as anode in the SVC and the distal as cathode in the apex of the RV. Atrial tachyarrhythmias were induced by right atrial burst pacing. If the arrhythmia sustained > 1 minute, biphasic shocks synchronized with the R wave were delivered using the implanted device, beginning with an energy of 4 J. If 4 J failed to terminate the arrhythmia, energy was increased stepwise, if the first shock was successful, a step-down testing was performed after reinduction of atrial tachyarrhythmias. The mean atrial defibrillation threshold was 2.3 +/- 1.2 J (range, 0.5-5 J). A total of 154 shocks were delivered and no adverse effects were observed. The mean defibrillation threshold for atrial flutter was somewhat lower than that for AF (1.8 +/- 1 J vs 2.7 +/- 1.4 J, P = 0.08). There was no correlation between the atrial defibrillation threshold and a history of previously occurring atrial tachyarrhythmias, the kind of the underlying heart disease, a prescription of antiarrhythmic drugs, the dimension of the LA, the LVEF, or the ventricular DFT. Internal atrial cardioversion of short duration atrial tachyarrhythmias using a transvenous single lead system designed for ventricular defibrillation is feasible and safe at low energies, and may have important clinical applications.

  20. Initial clinical experience with ambulatory use of an implantable atrial defibrillator for conversion of atrial fibrillation. Metrix Investigators.

    PubMed

    Daoud, E G; Timmermans, C; Fellows, C; Hoyt, R; Lemery, R; Dawson, K; Ayers, G M

    2000-09-19

    A recent study has shown that the implantable atrial defibrillator can restore sinus rhythm in patients with recurrent atrial fibrillation when therapy was delivered under physician observation. The objective of this study was to evaluate the safety and efficacy of ambulatory use of the implantable atrial defibrillator. An atrial defibrillator was implanted in 105 patients (75 men; mean age, 59+/-12 years) with recurrent, symptomatic, drug-refractory atrial fibrillation. After successful 3-month testing, patients could transition to ambulatory delivery of shock therapy. Patients completed questionnaires regarding shock therapy discomfort and therapy satisfaction using a 10-point visual-analog scale (1 represented "not at all," 10 represented "extremely") after each treated episode of atrial fibrillation. During a mean follow-up of 11.7 months, 48 of 105 patients satisfied criteria for transition and received therapy for 275 episodes of atrial fibrillation. Overall shock therapy efficacy was 90% with 1.6+/-1.2 shocks delivered per episode (median, 1). Patients rated shock discomfort as 5.2+/-2.4 for successful therapy and 4.2+/-2.2 for unsuccessful therapy (P:>0.05). The satisfaction score was higher for successful versus unsuccessful therapy (3.4+/-3. 3 versus 8.7+/-1.3, P:<0.05). There was no ventricular proarrhythmia observed throughout the course of this study. Ambulatory use of an implantable atrial defibrillator can safely and successfully convert most episodes of atrial fibrillation, often requiring only a single shock. Successful therapy is associated with high satisfaction and only moderate discomfort.

Top