Sample records for fracture displacement consistent

  1. Is fibular fracture displacement consistent with tibiotalar displacement?

    PubMed

    van den Bekerom, Michel P J; van Dijk, C Niek

    2010-04-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle fractures is based on the notion of elevated intraarticular contact pressures with lateral displacement. To diagnose these injuries, we presumed that in patients with a fibular fracture with at least 2 mm fracture displacement, the lateral malleolus and talus have moved at least 2 mm in a lateral direction without medial displacement of the proximal fibula. We reviewed 55 adult patients treated operatively for a supination-external rotation II ankle fracture (2 mm or more fibular fracture displacement) between 1990 and 1998. On standard radiographs, distance from the tibia to the proximal fibula, distance from the tibia to the distal fibula, and displacement at the level of the fibular fracture were measured. These distances were compared preoperatively and postoperatively. We concluded tibiotalar displacement cannot be reliably assessed at the level of the fracture. Based on this and other studies, we believe there is little evidence to perform open reduction and internal fixation of supination-external rotation II ankle fractures. Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.

  2. The effect of early operative stabilization on late displacement of zone I and II sacral fractures.

    PubMed

    Emohare, Osa; Slinkard, Nathaniel; Lafferty, Paul; Vang, Sandy; Morgan, Robert

    2013-02-01

    This study was designed to evaluate the effect on displacement of early operative stabilization on unstable fractures when compared to stable fractures of the sacrum. Patient consisted of those sustaining traumatic pelvic fractures that also included sacral fractures of Denis type I and type II classification, who were over 18 at the time of the study. Patients were managed emergently, as judged appropriate at the time and then subsequently divided into two cohorts, comprising those who were either treated operatively or non-operatively. The operative group comprised those treated with either internal fixation or external fixation. Twenty-eight patients had zone II fractures, and 20 had zone I fractures. Zone II fractures showed average displacements of 6.5mm and 6.9mm in the rostral-caudal and anteroposterior directions, respectively, at final follow up. Zone I fractures had average displacements of 6.6mm and 6.1mm in both directions. There were no significant differences between zone I and II sacral fractures (rostral-caudal P=0.74, anteroposterior P=0.24). Average changes in fracture displacement in patients with zone I fractures were 0.6-1.0mm in both directions. Average changes in zone II fractures were 1.8-1.5mm in both directions. There were no significant differences between the average changes in zone I and II fractures in any direction (rostral-caudal P=0.64, anteroposterior P=0.68) or in average displacements at final follow up in any of zone or the entire cohort. Statistically significant differences were noted in average changes in displacement in zone II fractures in the anteroposterior plane (P=0.03) and the overall cohort in the anteroposterior plane (P=0.02). Operative fixation for unstable sacral fractures ensures displacement at follow up is comparable with stable fractures treated non operatively. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. The Distal Humerus Axial View: Assessment of Displacement in Medial Epicondyle Fractures.

    PubMed

    Souder, Christopher D; Farnsworth, Christine L; McNeil, Natalie P; Bomar, James D; Edmonds, Eric W

    2015-01-01

    The assessment and treatment of childhood medial epicondyle humerus fractures continues to be associated with significant debate. Several studies demonstrate that standard radiographic views are unable to accurately portray the true displacement. Without reliable ways to assess the amount of displacement, how can we debate treatment and outcomes? This study introduces a novel imaging technique for the evaluation of medial epicondyle fractures. An osteotomy of a cadaveric humerus was performed to simulate a medial epicondyle fracture. Plain radiographs were obtained with the fracture fragment displaced anteriorly in 2-mm increments between 0 and 18 mm. Anteroposterior (AP), internal oblique (IR), lateral (LAT), and distal humerus axial (AXIAL) views were performed. Axial images were obtained by positioning the central ray above the shoulder at 15 to 20 degrees from the long axis of the humerus, centered on the distal humerus. Displacement (mm) was measured by 7 orthopaedic surgeons on digital radiographs. At 10 mm displacement, AP views underestimated displacement by 5.5±0.6 mm and IR views underestimated by 3.8±2.1 mm. On LAT views, readers were not able to visualize fragments with <10 mm displacement. Displacement ≥10 mm from LAT views was overestimated by 1 reader by up to 4.6 mm and underestimated by others by up to 18.0 mm. AXIAL images more closely estimated the true amount of displacement, with a mean 1.5±1.1 mm error in measurement for <10 mm displacement and a mean 0.8±0.7 mm error for displacements of ≥10 mm. AXIAL measurements correlated strongly with the actual displacement (r=0.998, P<0.05); AP measurements did not (r=0.655, P=0.55). Intraclass correlation coefficient (ICC) was 0.257 for AP and IR measurements; ICC was 0.974 for AXIAL measurements. Standard imaging, consisting of AP, IR, and LAT radiographs, consistently underestimates the actual displacement of medial epicondyle humerus fractures. The newly described AXIAL projection more accurately and reliably demonstrated the true displacement while reducing the need for advanced imaging such as computed tomography. This simple view can be easily obtained at a clinic visit, enhancing the surgeon's ability to determine the true displacement.

  4. Radiography versus computed tomography for displacement assessment in calcaneal fractures.

    PubMed

    Ogawa, Brent K; Charlton, Timothy P; Thordarson, David B

    2009-10-01

    Coronal computed tomography (CT) scans are commonly used in fracture classification systems for calcaneus fractures. However, they may not accurately reflect the amount of fracture displacement. The purpose of this paper was to determine whether lateral radiographs provide superior assessment of the displacement of the posterior facet compared to coronal CT scans. Lateral radiographs of calcaneus fractures were compared with CT coronal images of the posterior facet in 30 displaced intra-articular calcaneus fractures. The average patient age was 39 years old. Using a Picture Archiving and Communication System (PACS), measurements were obtained to quantify the amount of displacement on the lateral radiograph and compared with the amount of depression on corresponding coronal CT scans. On lateral radiographs, the angle of the depressed portion of the posterior facet relative to the undersurface of the calcaneus averaged 28.2 degrees; Bohler's angle averaged 12.7 degrees. These numbers were poorly correlated (r = 0.25). In corresponding CT images from posterior to anterior, the difference in the amount of displacement of the lateral portion of the displaced articular facet versus the nondisplaced medial, constant fragment, was minimal and consistently underestimated the amount of displacement. Underestimation of the amount of depression and rotation of the posterior facet fragment was seen on the coronal CT scan. We attribute this finding to the combined rotation and depression of the posterior facet which may not be measured accurately with the typical semicoronal CT orientation. While sagittal reconstructed images would show this depression better, if they are unavailable we recommend using lateral radiographs to better gauge the amount of fracture displacement.

  5. Patterns of fracture and tidal stresses due to nonsynchronous rotation - Implications for fracturing on Europa

    NASA Technical Reports Server (NTRS)

    Helfenstein, P.; Parmentier, E. M.

    1985-01-01

    This study considers the global patterns of fracture that would result from nonsynchronous rotation of a tidally distorted planetary body. The incremental horizontal stresses in a thin elastic or viscous shell due to a small displacement of the axis of maximum tidal elongation are derived, and the resulting stress distributions are applied to interpret the observed pattern of fracture lineaments on Europa. The observed pattern of lineaments can be explained by nonsynchronous rotation if these features formed by tension fracturing and dike emplacement. Tension fracturing can occur for a small displacement of the tidal axis, so that the resulting lineaments may be consistent with other evidence suggesting a young age for the surface.

  6. Fracture of the fabella.

    PubMed

    Woo, C C

    1988-10-01

    A very rare case of traumatic avulsion fracture of the fabella in a middle-age lady, presented as intermittent posterolateral localized knee pain accentuated by compression against the lateral femoral condyle and by active and passive knee extension, is illustrated. The accumulated chronic microtrauma of the osteoarthritic fabello femoral joint in this lady especially during the whip-kick of daily breaststroke swimming for over 30 yr, may precipitate a fabella stress fracture. Radiographs reveal bilateral fabellae with a left bipartite fabella as a stress fracture traversing it without displacement; this later became a completely displaced bipartite avulsion fracture after accidental knee hyperextension. Conservative treatment consisted of anti-inflammatory/analgesic cream, cryotherapy, TENS, strapping and avoiding knee hyperextension.

  7. Crossover from capillary fingering to viscous fingering in a rough fracture

    NASA Astrophysics Data System (ADS)

    Hu, R.; Chen, Y.; Wu, D. S.

    2017-12-01

    Controlled by the competition between capillary and viscous forces, the displacement patterns of one fluid displacing another more viscous one exhibit capillary fingering, viscous fingering, and the crossover between the two. Although extensive studies have investigated viscous and capillary fingerings in porous and fractured media, a few studies focused on the crossover in rough fractures, and how viscous and capillary forces affect the crossover remains unclear. Using a transparent fracture visualization system, we studied how the competition impacts the crossover in a horizontal rough fracture. Drainage experiments of water displacing oil were conducted at seven flow rates (capillary number log10Ca ranging from -7.07 to -3.07) and four viscosity ratios (M = 1/1000, 1/500, 1/100 and 1/50). We consistently observed lower invading fluid saturations in the crossover zone. In addition, we proposed a phase diagram for the displacement patterns in a rough fracture that is consistent with similar studies in porous media. Based on real-time imaging and statistical analysis of the invasion morphology, we showed that the competition between the capillary and viscous forces is responsible for the saturation reduction in the crossover zone. In this zone, finger propagation toward the outlet (characteristic of viscous fingering) as well as void-filling in the transverse and backward directions (characteristic of capillary fingering), are both suppressed. Therefore, the invading fluid tends to occupy larger apertures with higher characteristic front velocity, promoting void-filling toward the outlet with thinner finger growth and resulting in a larger volume of defending fluid left behind.

  8. Visualizing and quantifying the crossover from capillary fingering to viscous fingering in a rough fracture

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Feng; Fang, Shu; Wu, Dong-Sheng; Hu, Ran

    2017-09-01

    Immiscible fluid-fluid displacement in permeable media is important in many subsurface processes, including enhanced oil recovery and geological CO2 sequestration. Controlled by capillary and viscous forces, displacement patterns of one fluid displacing another more viscous one exhibit capillary and viscous fingering, and crossover between the two. Although extensive studies investigated viscous and capillary fingering in porous media, a few studies focused on the crossover in rough fractures, and how viscous and capillary forces affect the crossover remains unclear. Using a transparent fracture-visualization system, we studied how the two forces impact the crossover in a horizontal rough fracture. Drainage experiments of water displacing oil were conducted at seven flow rates (capillary number log10Ca ranging from -7.07 to -3.07) and four viscosity ratios (M=1/1000,1/500,1/100 and 1/50). We consistently observed lower invading fluid saturations in the crossover zone. We also proposed a phase diagram for the displacement patterns in a rough fracture that is consistent with similar studies in porous media. Based on real-time imaging and statistical analysis of the invasion morphology, we showed that the competition between capillary and viscous forces is responsible for the saturation reduction in the crossover zone. In this zone, finger propagation toward the outlet (characteristic of viscous fingering) as well as void-filling in the transverse/backward directions (characteristic of capillary fingering), are both suppressed. Therefore, the invading fluid tends to occupy larger apertures with higher characteristic front velocity, promoting void-filling toward the outlet with thinner finger growth and resulting in a larger volume of defending fluid left behind.

  9. Association of Ipsilateral Rib Fractures With Displacement of Midshaft Clavicle Fractures.

    PubMed

    Stahl, Daniel; Ellington, Matthew; Brennan, Kindyle; Brennan, Michael

    2017-04-01

    To determine whether the presence of ipsilateral rib fractures affects the rate of a clavicle fracture being unstable (>100% displacement). A retrospective review from 2002-2013 performed at a single level 1 trauma center evaluated 243 midshaft clavicle fractures. Single Level 1 trauma center. These fractures were subdivided into those with ipsilateral rib fractures (CIR; n = 149) and those without ipsilateral rib fractures (CnIR; n = 94). The amount of displacement was measured on the initial injury radiograph and subsequent follow-up radiographs. Fractures were classified into either <100% displacement or >100% displacement, based on anteroposterior radiographs. Ipsilateral rib fractures were recorded based on which number rib was fractured and the total number of fractured ribs. One hundred sixteen (78%) of the CIR group and 51 (54%) of the CnIR group were found to have >100% displacement at follow-up (P = 0.0047). Seventy-two percent of the CIR group demonstrated progression from <100% to >100% displacement of the fracture compared with only 54% of the CnIR group (P < 0.05). The odds ratio for progression of the clavicle fracture to >100% was 4.08 (P = 0.000194) when ribs 1-4 were fractured and not significant for rib fractures 5-8 or 9-12. The presence of concomitant ipsilateral rib fractures significantly increases the rate of midshaft clavicle fractures being >100% displaced. In addition, a fracture involving the upper one-third of the ribs significantly increases the rate of the clavicle fracture being >100% displaced on early follow-up. Clavicle fractures with associated ipsilateral rib fractures tend to demonstrate an increased amount of displacement on follow-up radiographs compared with those without ipsilateral rib fractures. Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

  10. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    PubMed

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p < 0.001). Only twelve (10.2%) of the 118 cases of peroneal tendon displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  11. Medial joint space widening of the ankle in displaced Tillaux and Triplane fractures in children.

    PubMed

    Gourineni, Prasad; Gupta, Asheesh

    2011-10-01

    Tillaux and Triplane fractures occur in children predominantly from external rotation mechanism. We hypothesized that in displaced fractures, the talus would shift laterally along with the distal fibula and the distal tibial epiphyseal fragment increasing the medial joint space. Consecutive cases evaluated retrospectively. Level I and Level II centers. Twenty-two skeletally immature patients with 14 displaced Triplane fractures and eight displaced Tillaux fractures were evaluated for medial joint space widening. Measurement of fracture displacement and medial joint space widening before and after intervention. Thirteen Triplane and six Tillaux fractures (86%) showed medial space widening of 1 to 9 mm and equal to the amount of fracture displacement. Reduction of the fracture reduced the medial space to normal. There were no known complications. Medial space widening of the ankle may be a sign of ankle fracture displacement. Anatomic reduction of the fracture reduces the medial space and may improve the results in Tillaux and Triplane fractures.

  12. Early Weightbearing After Operatively Treated Ankle Fractures: A Biomechanical Analysis.

    PubMed

    Tan, Eric W; Sirisreetreerux, Norachart; Paez, Adrian G; Parks, Brent G; Schon, Lew C; Hasenboehler, Erik A

    2016-06-01

    No consensus exists regarding the timing of weightbearing after surgical fixation of unstable traumatic ankle fractures. We evaluated fracture displacement and timing of displacement with simulated early weightbearing in a cadaveric model. Twenty-four fresh-frozen lower extremities were assigned to Group 1, bimalleolar ankle fracture (n=6); Group 2, trimalleolar ankle fracture with unfixed small posterior malleolar fracture (n=9); or Group 3, trimalleolar ankle fracture with fixed large posterior malleolar fracture (n=9) and tested with axial compressive load at 3 Hz from 0 to 1000 N for 250 000 cycles to simulate 5 weeks of full weightbearing. Displacement was measured by differential variable reluctance transducer. The average motion at all fracture sites in all groups was significantly less than 1 mm (P < .05). Group 1 displacement of the lateral and medial malleolus fracture was 0.1±0.1 mm and 0.4±0.4 mm, respectively. Group 2 displacement of the lateral, medial, and posterior malleolar fracture was 0.6±0.4 mm, 0.5±0.4 mm, and 0.5±0.6 mm, respectively. Group 3 displacement of the lateral, medial, and posterior malleolar fracture was 0.1±0.1 mm, 0.5±0.7 mm, and 0.5±0.4 mm, respectively. The majority of displacement (64.0% to 92.3%) occurred in the first 50 000 cycles. There was no correlation between fracture displacement and bone mineral density. No significant fracture displacement, no hardware failure, and no new fractures occurred in a cadaveric model of early weightbearing in unstable ankle fracture after open reduction and internal fixation. This study supports further investigation of early weightbearing postoperative protocols after fixation of unstable ankle fractures. © The Author(s) 2016.

  13. Accuracy of radiographs in assessment of displacement in lateral humeral condyle fractures.

    PubMed

    Knutsen, Ashleen; Avoian, Tigran; Borkowski, Sean L; Ebramzadeh, Edward; Zionts, Lewis E; Sangiorgio, Sophia N

    2014-02-01

    Determining the magnitude of displacement in pediatric lateral humeral condyle fractures can be difficult. The purpose of this study was to (1) assess the effect of forearm rotation on true fracture displacement using a cadaver model and to (2) determine the accuracy of radiographic measurements of the fracture gap. A non-displaced fracture was created in three human cadaveric arms. The specimens were mounted on a custom apparatus allowing forearm rotation with the humerus fixed. First, the effect of pure rotation on fracture displacement was simulated by rotating the forearm from supination to pronation about the central axis of the forearm, to isolate the effects of muscle pull. Then, the clinical condition of obtaining a lateral oblique radiograph was simulated by rotating the forearm about the medial aspect of the forearm. Fracture displacements were measured using a motion-capture system (true-displacement) and clinical radiographs (apparent-displacement). During pure rotation of the forearm, there were no significant differences in fracture displacement between supination and pronation, with changes in displacement of <1.0 mm. During rotation about the medial aspect of the forearm, there was a significant difference in true displacements between supination and pronation at the posterior edge (p < 0.05). Overall, true fracture displacement measurements were larger than apparent radiographic displacement measurements, with differences from 1.6 to 6.0 mm, suggesting that the current clinical methods may not be sensitive enough to detect a displacement of 2.0 mm, especially when positioning the upper extremity for an internal oblique lateral radiograph.

  14. Paediatric lateral humeral condyle fractures: internal oblique radiographs alter the course of conservative treatment.

    PubMed

    Kurtulmuş, Tuhan; Sağlam, Necdet; Saka, Gursel; Avcı, Cem Coşkun; Uğurlar, Meriç; Türker, Mehmet

    2014-10-01

    At first presentation of paediatric humeral lateral condyle fractures, radiological methods such as computerised tomography, ultrasonography, magnetic resonance imaging, arthrography, and internal oblique radiography are used to determine stability. Very few studies show which radiological method should be used to evaluate displacement at follow-up for conservatively treated patients. This study aimed to show that internal oblique radiography is a simple, effective method to determine the subsequent development of fracture displacement in patients with an initially non-displaced or minimally displaced fracture. In this retrospective study, 27 paediatric patients with non-displaced or minimally displaced (<2 mm) humerus lateral condyle fracture were evaluated by elbow anteroposterior radiograph. The degree of fracture displacement was evaluated by anteroposterior then by internal oblique radiographs. The first follow-up was made between the 5th and 8th day and thereafter at intervals of 7-10 days. Of the 27 patients identified with non-displaced or minimally displaced (<2 mm) fracture from the initial anteroposterior radiograph, 16 were accepted as displacement >2 mm as a result of the evaluation of the internal oblique radiography and underwent surgery. At follow-up, 2 of 11 patients were defined with displacement from anteroposterior and internal oblique radiographs and 4 from the internal oblique radiographs and underwent surgery. Conservative treatment was applied to 5 patients. Internal oblique radiography is the best imaging showing subsequent fracture displacement in initially non-displaced or minimally displaced humerus lateral condyle fractures. At the first week follow-up, anteroposterior and particularly internal oblique radiographs should be taken of conservatively treated patients.

  15. Case report. Pediatric carpal fracture dislocation.

    PubMed

    DeCoster, T A; Faherty, S; Morris, A L

    1994-01-01

    Transcarpal fractures in children are rare in the orthopaedic literature. This is a case report of a 10-year-old boy who sustained fractures across the distal radius, scaphoid, lunate, and triquetrum with gross displacement. Treatment consisted of open reduction with internal fixation of the fractures and ligamentous repair through a combined dorsal and palmar approach. The injury healed with good wrist function but abnormal carpal development. This unusual pattern of injury is described so that it may be more readily appreciated in the future.

  16. [Conservative treatment of metacarpal fracture].

    PubMed

    Prokop, A; Helling, H J; Kulus, S; Rehm, K E

    2002-01-01

    Conservative treatment of meatacarpale fracture is recommended if there are no joint displacement, rotation failures, displacement over 30 degrees ad axim and shortening over 5 mm. Operative procedures should be done in open fractures and serial of fractures of metacarpale bones. Early functionally treatment should be done in stable, not displaced fractures. Cast can be used only for a short time in full extended position of fingers and flexion in metacarpo-phalangeal joint in 60-90 degrees. Twin-tapes after reduction of edema allowed free range of motion by fixed rotation. Closed reduction of displaced fractures of fifth metacarpal bone (boxer's fracture) isn't successful. Cases with displacement over 30 degrees may be operatively treated by intramedullary stabilization.

  17. [Treatment of metacarpal fractures].

    PubMed

    Prokop, A; Jubel, A; Helling, H J; Kulus, S; Rehm, K E

    2002-09-01

    Conservative treatment of metacarpal fractures is recommended if there is no joint displacement, malrotation, displacement of over 30 degrees ad axim and shortening of over 5 mm. Surgery should be performed in open fractures and serial fractures of metacarpal bone. Early functional treatment should be carried out in stable, not displaced fractures. A cast can be used for a short period in full extended position of fingers and flexion in metacarpo-phalangeal joint in 60 - 90 degrees. Twin-tape fixation allows functional treatment after soft-tissue swelling has disappeared. Closed reduction of displaced fractures of the fifth metacarpal bone (boxer's fracture) is not successful. Cases with displacement of over 30 degrees may be treated surgically by intramedullary stabilisation.

  18. Analysis of the Postoperative Displacement of Trochanteric Fractures on Lateral View Radiographs.

    PubMed

    Furui, Atsuo; Terada, Nobuki

    2017-08-01

    Achieving sufficient support of the anterior cortex of the femoral neck is a fundamental goal of the reduction of trochanteric fractures. However, anterior-cortex support is often lost after the fracture reduction. Our aim was to analyze factors contributing to the postoperative displacement of an acceptably reduced trochanteric fracture. The cases of 40 patients with a post-reduction Ikuta subtype N fracture alignment were reviewed. All fractures were fixed with 135° free-sliding plates. On postoperative day 14, patients were classified into two groups: those with retention of the Ikuta subtype N alignment, and those with progression to Ikuta subtype P alignment. The clinical and radiological factors were evaluated between the groups. In addition, to define one of the factors, i.e., the postoperative rotational displacement between the proximal and distal fragments, the relationship between radiographic findings and computed tomography image measurements was assessed in 15 of the 40 patients. Angulation at the fracture site on lateral view radiographs was defined as postoperative rotational displacement, and unstable trochanteric fractures and postoperative rotational displacement were identified as significant risk factors for the postoperative displacement. Therefore, cautious and careful follow-up is warranted for patients with unstable trochanteric fractures or fractures having rotational displacement.

  19. Minimally displaced clavicle fracture after high-energy injury: are they likely to displace?

    PubMed

    Riehl, John T; Athans, Bill J; Munro, Mark W; Langford, Joshua R; Kupiszewski, Stanley J; Haidukewych, George J; Koval, Kenneth J

    2014-06-01

    Nondisplaced or minimally displaced clavicle fractures are often considered to be benign injuries. These fractures in the trauma patient population, however, may deserve closer follow-up than their low-energy counterparts. We sought to determine the initial assessment performed on these patients and the rate of subsequent fracture displacement in patients sustaining high-energy trauma when a supine chest radiograph on initial trauma survey revealed a well-aligned clavicle fracture. We retrospectively reviewed the cases of trauma alert patients who sustained a midshaft clavicle fracture (AO/OTA type 15-B) with less than 100% displacement treated at a single level 1 trauma centre between 2005 and 2010. We compared fracture displacement on initial supine chest radiographs and follow-up radiographs. Orthopedic consultation and the type of imaging studies obtained were also recorded. Ninety-five patients with clavicle fractures met the inclusion criteria. On follow-up, 57 (60.0%) had displacement of 100% or more of the shaft width. Most patients (63.2%) in our study had an orthopedic consultation during their hospital admission, and 27.4% had clavicle radiographs taken on the day of admission. Clavicle fractures in patients with a high-energy mechanism of injury are prone to fracture displacement, even when initial supine chest radiographs show nondisplacement. We recommend clavicle films as part of the initial evaluation for all patients with clavicle fractures and early follow-up within the first 2 weeks of injury.

  20. Minimally displaced clavicle fracture after high-energy injury: Are they likely to displace?

    PubMed Central

    Riehl, John T.; Athans, Bill J.; Munro, Mark W.; Langford, Joshua R.; Kupiszewski, Stanley J.; Haidukewych, George J.; Koval, Kenneth J.

    2014-01-01

    Background Nondisplaced or minimally displaced clavicle fractures are often considered to be benign injuries. These fractures in the trauma patient population, however, may deserve closer follow-up than their low-energy counterparts. We sought to determine the initial assessment performed on these patients and the rate of subsequent fracture displacement in patients sustaining high-energy trauma when a supine chest radiograph on initial trauma survey revealed a well-aligned clavicle fracture. Methods We retrospectively reviewed the cases of trauma alert patients who sustained a midshaft clavicle fracture (AO/OTA type 15-B) with less than 100% displacement treated at a single level 1 trauma centre between 2005 and 2010. We compared fracture displacement on initial supine chest radiographs and follow-up radiographs. Orthopedic consultation and the type of imaging studies obtained were also recorded. Results Ninety-five patients with clavicle fractures met the inclusion criteria. On follow-up, 57 (60.0%) had displacement of 100% or more of the shaft width. Most patients (63.2%) in our study had an orthopedic consultation during their hospital admission, and 27.4% had clavicle radiographs taken on the day of admission. Conclusion Clavicle fractures in patients with a high-energy mechanism of injury are prone to fracture displacement, even when initial supine chest radiographs show nondisplacement. We recommend clavicle films as part of the initial evaluation for all patients with clavicle fractures and early follow-up within the first 2 weeks of injury. PMID:24869608

  1. Displaced mid-shaft clavicular fractures: is conservative treatment still preferred?

    PubMed

    Brin, Yaron S; Palmanovich, Ezequiel; Dolev, Eran; Nyska, Meir; Kish, Benyamin J

    2014-12-01

    A clavicular fracture accounts for 2.6%-5% of adult fractures. Fractures in the middle-third (OTA 15-B) represent 69%-82% of all clavicular fractures. There is no consensus among orthopedic surgeons regarding treatment for these fractures: many support conservative treatment even for displaced middle-third clavicular fractures, while others choose operative treatment. To assess the attitudes of orthopedic surgeons regarding treatment of displaced mid-shaft clavicular fractures. We conducted a survey in which we interviewed orthopedic surgeons from various countries during the 2012 EFORT meeting in Berlin. The questionnaire included an X-ray of a displaced middle-third clavicular fracture, as well as questions regarding the surgeon's proposed treatment plan. A total of 177 orthopedic surgeons completed the questionnaire; 49% preferred operative treatment for a displaced middle-third clavicular fracture. Among the orthopedic trauma specialists, 58% suggested operative treatment, as did 82% of shoulder specialists. Most surgeons preferred a locking plate for fixation. The treatment approach for a displaced middle-third clavicular fracture seems to be evenly split between conservative and operative approaches. The tendency toward operative treatment was.even more remarkable among orthopedic trauma specialists and shoulder specialists who completed the questionnaire. Most surgeons prefer a locking plate as a fixation system for this type of fracture.

  2. Radiographic diagnosis of sagittal plane rotational displacement in pelvic fractures: a cadaveric model and clinical case study.

    PubMed

    Shui, Xiaolong; Ying, Xiaozhou; Kong, Jianzhong; Feng, Yongzeng; Hu, Wei; Guo, Xiaoshan; Wang, Gang

    2015-08-01

    Our objective was to measure the sagittal plane rotational (flexion and extension) displacement of hemipelvis radiologically and analyze the ratio of flexion and extension displacement of unstable pelvic fractures. We used 8 cadaveric models to study the radiographic evidence of pelvic fractures in the sagittal plane. We performed pelvic osteotomy on 8 cadavers to simulate anterior and posterior pelvic ring injury. Radiological data were measured in the flexion and extension group under different angles (5°, 10°, 15°, 20°, and 25°). We retrospectively reviewed 164 patients who were diagnosed with a unilateral fracture of the pelvis. Pelvic ring displacement was identified and recorded radiographically in cadaveric models. The flexion and extension displacement of pelvic fractures was measured in terms of the vertical distance of fracture from the top of iliac crest to the pubic tubercle (CD) or from the top of iliac crest to the lowest point of ischial tuberosity (AB). Fifty-seven pelves showed flexion displacement and 15 showed extension displacement. Closed reduction including internal fixation and external fixation was successfully used in 141 cases (86.0 %). The success rates of closed reduction in flexion and extension displacement groups were 77 and 73 %, respectively, which were lower than in unstable pelvic ring fractures. The sagittal plane rotation (flexion and extension) displacement of pelvic fractures could be measured by special points and lines on the radiographs. Minimally invasive reduction should be based on clearly identified differences between the sagittal plane rotation and the vertical displacement of pelvic fractures.

  3. Positional Change in Displacement of Midshaft Clavicle Fractures: An Aid to Initial Evaluation.

    PubMed

    Malik, Awais; Jazini, Ehsan; Song, Xuyang; Johal, Herman; OʼHara, Nathan; Slobogean, Gerard; Abzug, Joshua M

    2017-01-01

    To determine how change in position affects displacement of midshaft clavicle fractures. Retrospective review. Level I Trauma Center. Eighty patients with displaced midshaft clavicle fractures and presence of supine and semiupright or upright chest radiographs taken within 2 weeks of each other. Supine, semiupright, and upright chest radiographs. Fracture shortening and vertical displacement on supine, semiupright, and upright radiographs. Mean vertical displacement was 9.42 mm [95% confidence interval (95% CI), 8.07-10.77 mm], 11.78 mm (95% CI, 10.25-13.32 mm), and 15.72 mm (95% CI, 13.71-17.72 mm) in supine, semiupright, and upright positions, respectively. Fracture shortening was -0.41 mm (95% CI, -2.53 to 1.70 mm), 2.11 mm (95% CI, -0.84 to 5.07), and 4.86 mm (95% CI, 1.66-8.06 mm) in supine, semiupright, and upright positions, respectively. Change in position from supine to upright significantly increased both vertical displacement and fracture shortening (P < 0.001). In the upright position, the proportion of patients who met operative indications (fracture shortening >20 mm) was 3 times greater when compared with that in the supine position (upright 17.65%; supine 5.88%, P = 0.06). Positional changes in fracture displacement were not associated with body mass index, age, or gender. Patient position is associated with significant changes in fracture displacement. Over 3 times more patients meet operative indications when placed in the upright versus supine position. An upright chest radiograph should be obtained to evaluate midshaft clavicle fracture displacement, as it represents the physiologic stress across the fracture when considering nonoperative management. Prognostic level IV. See Instructions for Authors for a complete description of levels of evidence.

  4. [Fracture Type and Injury-to-Surgery Interval as Risk Factors for Avascular Necrosis of the Femoral Head after Internal Fixation of Intracapsular Femoral Neck Fracture].

    PubMed

    Popelka, O; Skála-Rosenbaum, J; Bartoška, R; Waldauf, P; Krbec, M; Džupa, V

    2015-01-01

    The aim of the study was to investigate the occurrence of avascular necrosis (AVN) of the femoral head following the osteosynthesis of intracapsular fracture of the femoral neck in relation to the time interval between injury and surgery and the type of fracture. The data of patients with intracapsular fractures of the femoral neck surgically treated in the period from 2001 to 2011 were reviewed. Of 1555 patients treated for this fracture, 125 (7%) underwent osteosynthesis. The evaluated group included 115 patients who came for examination at one-year follow-up. There were 59 (52%) women and 56 (48%) men. Dynamic hip screw (DHS) osteosynthesis with an anti-rotation screw was performed in 103 patients and lag-screw osteosynthesis involving three parallel cannulated cancellous screws was employed in 12 patients. The patients were allocated to groups according to the injury-to-surgery interval and to sub-groups on the basis of the Garden classification of femoral fracture stage. In the group of 58 patients treated within 6 h of injury, AVN developed in 10 (17%). When the type of fracture was considered, 4% of the non-displaced fractures and 30% of the displaced fractures developed AVN. The patients with Garden stage I and II (non-displaced) fractures treated within 6 h of injury had a significantly lower risk of AVN development than those with Garden stage III or IV (displaced) fractures. The group treated between 6 and 24 post-injury hours comprised 21 patients, of whom four (19%) had AVN. In non-displaced and displaced fracture sub-groups, 25% of the patients in the former and 16% in the latter had AVN. The stage of displacement had no effect on AVN development. The two groups together (patients treated by 24 h) had a significantly lower AVN incidence than the patients treated after 24 h (p = 0.0025). In this group of 36 patients, 16 had AVN (44%) and the fracture stage made no significant difference (p = 0.6985; nondisplacement sub-group, 41%; displacement sub-group, 55%). The study showed a significantly lower AVN occurrence in the patients surgically treated within 24 h of injury. In the patients treated within 6 h of injury, AVN incidence was significantly lower in the patients with non-displaced fractures, as compared with those who had displaced fractures. This was not true for the two patient groups treated later (6-24 and later than 24 h) in which the differences between AVN development after non-displaced fractures and that after displaced fractures were similar.

  5. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.

    PubMed

    Chan, Gareth; Korac, Zelimir; Miletic, Matija; Vidovic, Dinko; Phadnis, Joideep; Bakota, Bore

    2017-11-01

    Surgical fixation of displaced midshaft clavicle fractures is predominantly achieved with intramedullary (IM) or plate fixation. Both techniques have potential pitfalls: plate fixation involves greater periosteal stripping and protuberance of the implant, whereas IM fixation may be associated with implant-related complications, such as migration or skin irritation, which may lead to further surgery for implant removal. The aim of this study was to compare these two methods in simple (Robinson 2b.1) and multifragmentary (Robinson 2b.2) displaced midshaft clavicle fractures. A total of 133 consecutive patients who underwent surgical fixation for a displaced midshaft clavicle fracture with either IM fixation using a 2.5-mm Kirschner wire or plate fixation using an 8-hole Dynamic Compression Plate (DCP) were retrospectively reviewed. Follow-up was a minimum of 1 year. The patients were allocated into two injury groups: displaced simple 2-part fractures (64 IM vs. 16 DCP) and displaced multifragmentary fractures (27 IM vs. 26 DCP). The major observed outcome measures were: infection rate, non-union rate, reoperation rate and postoperative range of motion (ROM). Rates of non-union for displaced 2-part fractures were 2/64 (3.13%) with IM fixation and 0/16 (0.00%) with plate fixation (p = 0.477). For displaced multifragmentary fractures, rates of non-union were 2/27 (7.41%) with IM fixation and 0/26 (0.00%) with plate fixation (p = 0.161). No significant difference was observed between the two fixation modalities in patient-reported time to regain ROM on the injured side for displaced 2-part fractures (p = 0.129) and displaced multifragmentary fractures (p = 0.070). Deep infection rate was zero (p = 1.000) overall in the study, and reoperation rate for IM and plate fixation, respectively, was 3.13% and 6.25% in the Robinson 2b.1 group (p = 0.559) and 7.41% and 7.69% in the Robinson 2b.2 group (p = 0.969). IM fixation of displaced midshaft clavicle fractures (Robinson 2b.1) has an equivalent non-union rate to plate fixation and similarly low complication and reoperation rates. For displaced midshaft multifragmentary clavicle fractures (Robinson 2b.2), the higher non-union rates observed with IM fixation leads us to recommend consideration of plate fixation for Robinson 2b.2 fractures. © 2017 Elsevier Ltd. All rights reserved.

  6. Displaced femoral neck fatigue fractures in military recruits.

    PubMed

    Pihlajamäki, Harri K; Ruohola, Juha-Petri; Kiuru, Martti J; Visuri, Tuomo I

    2006-09-01

    Displaced fatigue fractures of the femoral neck are uncommon, but they can lead to substantial patient morbidity. This study was performed to examine the incidence, long-term consequences, radiographic findings, risk factors, and complications associated with this fracture. Between 1975 and 1994, twenty-one military recruits sustained a displaced fatigue fracture of the femoral neck. Nineteen patients were followed for an average of eighteen years. Data regarding the population at risk, hospital records, initial and follow-up radiographs, and physical findings were analyzed. The impact of instructions from the Finnish Defense Forces, Department of Medical Services, provided in 1986 for prevention of femoral neck fatigue fractures was assessed. At our institution, the incidence of displaced fatigue fractures of the femoral neck was 5.3/100,000 service years from 1975 to 1986, prior to the introduction of the prevention regimen in 1986, and it was 2.3/100,000 service years (95% confidence interval, 0.11 to 1.31) from 1987 to 1994. The rate of Garden type-IV fractures decreased from 3.8 to 0/100,000 service years (95% confidence interval, 0 to 0.66) between the first and second time-periods. The detection of nondisplaced symptomatic fatigue fractures of the femoral neck increased from 15.5 to 53.2/100,000 service years (95% confidence interval, 2.27 to 5.21) between the two time-periods. Eighteen of the nineteen patients had had prodromal symptoms prior to the fracture displacement. Following fracture treatment, six patients had delayed union or nonunion of the fracture. Osteonecrosis of the femoral head developed in six patients and was significantly associated (p = 0.001) with shortening of the femoral neck. Severe osteoarthritis developed in eight patients. A displaced fatigue fracture of the femoral neck leads to long-term morbidity in a high percentage of patients. Most patients have prodromal symptoms, which provide an opportunity to prevent fracture displacement. Our results indicate that, in a military setting, an educational program can diminish the incidence of fatigue fracture displacement by increasing the awareness of these fractures and their prodromal symptoms and by facilitating diagnosis in the early stages before displacement occurs. Therapeutic Level III.

  7. Inversion of Coeval Shear and Normal Stress of Piton de la Fournaise Flank Displacement

    NASA Astrophysics Data System (ADS)

    Cayol, V.; Tridon, M.; Froger, J. L.; Augier, A.; Bachelery, P.

    2016-12-01

    The April 2007 eruption of Piton de la Fournaise was the biggest volcano eruptive crisis of the 20th and 21st centuries. InSAR captured a large (1.4 m) co-eruptive seaward slip of the volcano's eastern flank, which continued for more than a year at a decreasing rate. Co-eruptive uplift and post-eruptive subsidence were also observed. While it is generally agreed that flank displacement is induced by fault slip, we investigate wether this flank displacement might have been induced by a sheared sill, as suggested by observations of sheared sills at Piton des Neiges. To test this hypothesis, we develop a new method to invert a quadrangular curved source submitted to co-eval pressure and shear stress changes. This method, based on boundary elements, is applied to co-eruptive and post-eruptive InSAR data. We find that co-eruptive displacement is explained by a 2 km by 2 km detachment fault, parallel to the flank and probably coincident with a lithological discontinuity. The fracture is shallow enough to induce the co-eval uplift characteristic of a detachment fold. We determine the co-eruptive overpressure is zero, which indicates that the fracture is not a sheared sill. This finding confirms a previous determination obtained using a decision tree based on ratios of maximum displacements. The determined shear stress change of 2 MPa is conistent with the eastern flank loaded by previously intruded rift dikes. Post-eruptive displacement is well explained by slip and closure of the same fracture but over a larger (5 km by 8 km). This displacements is consistent with relaxation and the co-eruptive flank displacement and causal link between both displacement is investigated.

  8. Remodeling of a nontreated displaced parasymphyseal fracture of a child.

    PubMed

    Kerem, Hakan; Usluer, Ayşen; Yoleri, Levent

    2011-07-01

    There have been considerable advances in the management of craniomaxillofacial injuries in children. Conservative approaches such as close observation, a liquid-to-soft diet, and analgesics can be used for the management of mandibular fractures without displacement and malocclusion. However, displaced fractures need to be an anatomic reduction and immobilization. The basic principle of displaced mandibular fractures in both children and adults is the stabilization of fracture fragments forming the pretraumatic contour and occlusion state until osteosynthesis occurs. The major differences of pediatric fractures from adults are the flexibility of bones and very rapid healing pattern. Therefore, reduction in pediatric age group must be accomplished earlier. This case was an 11-year-old boy presented with a severely displaced parasymphyseal mandibular fracture resulting from a fall. He was given a soft diet and analgesic, given anti-inflammatory treatment of edema, and scheduled for operation. Subsequently, it was surprisingly observed that there was a significant improvement in the fracture line on the 12th posttraumatic day. The comparison of maxillofacial computed tomographic scans of the first and 12th posttraumatic days revealed a noteworthy remodeling and a remarkable approximation of the fracture lines. It can be concluded that bone remodelization in the pediatric age groups is perfect and very rapid, even in severely displaced fractures.

  9. Rate of displacement for Jakob Type 1 lateral condyle fractures treated with a cast.

    PubMed

    Zale, C; Winthrop, Z A; Hennrikus, W

    2018-04-01

    The aim of this retrospective study is to report the rate of displacement of Jakob Type 1 lateral condyle fractures that were initially treated in a cast. We performed a retrospective review of all patients that were treated for a non-displaced (Jakob Type 1 < 2 mm) lateral condyle fracture of the humerus at our institution between 2002 and 2015. A total of 59 patients were initially treated with casting. Five fractures displaced and were converted to a closed pinning treatment plan with a conversion rate of 8.5%. There was a mean of 13.2 days (4 to 21) between treatment by initial casting and closed pinning. This study demonstrates an 8.5% displacement and conversion rate from cast treatment to closed pinning for initially non-displaced Jakob Type 1 lateral condyle fractures of the humerus. The internal oblique radiograph is most accurate to determine displacement. We recommend obtaining an internal oblique view at initial evaluation and at follow-up in the cast for lateral condyle fractures. To minimize movement at the fracture site, we recommend treating Jakob Type 1 lateral condyle fractures with a long arm cast with the elbow at 90° and the forearm in the supine position with a sling-loop design. IV - retrospective therapeutic study.

  10. The number of displaced rib fractures is more predictive for complications in chest trauma patients.

    PubMed

    Chien, Chih-Ying; Chen, Yu-Hsien; Han, Shih-Tsung; Blaney, Gerald N; Huang, Ting-Shuo; Chen, Kuan-Fu

    2017-02-28

    Traumatic rib fractures can cause chest complications that need further treatment and hospitalization. We hypothesized that an increase in the number of displaced rib fractures will be accompanied by an increase in chest complications. We retrospectively reviewed the trauma registry between January 2013 and May 2015 in a teaching hospital in northeastern Taiwan. Patients admitted with chest trauma and rib fractures without concomitant severe brain, splenic, pelvic or liver injuries were included. The demographic data, such as gender, age, the index of coexistence disease, alcohol consumption, trauma mechanisms were analyzed as potential predictors of pulmonary complications. Pulmonary complications were defined as pneumothorax, hemothorax, flail chest, pulmonary contusion, and pneumonia. In the 29 months of the study period, a total of 3151 trauma patients were admitted to our hospital. Among them, 174 patients were enrolled for final analysis. The most common trauma mechanism was road traffic accidents (58.6%), mainly motorbike accidents (n = 70, 40.2%). Three or more displaced rib fractures had higher specificity for predicting complications, compared to three or more total rib fractures (95.5% vs 59.1%). Adjusting the severity of chest trauma using TTSS and Ribscore by multivariable logistic regression analysis, we found that three or more rib fractures or any displaced rib fracture was the most significant predictor for developing pulmonary complication (aOR: 5.49 95% CI: 1.82-16.55). Furthermore, there were 18/57 (31.6%) patients with fewer than three ribs fractures developed pulmonary complications. In these 18 patients, only five patients had delayed onset complications and four of them had at least one displaced rib fracture. In this retrospective cohort study, we found that the number of displaced or total rib fractures, bilateral rib fractures, and rib fractures in more than two areas were associated with the more chest complications. Furthermore, three or more rib fracture or any displacement were found to be the most sensitive risk factor for chest complications, independent of other risk factors or severity index. The number of displaced rib fractures could be a strong predictor for developing pulmonary complications. For patients with fewer than three rib fractures without rib displacement and initial lung or other organ injuries, outpatient management could be safe and efficient.

  11. Quantifying irreversible movement in steep, fractured bedrock permafrost on Matterhorn (CH)

    NASA Astrophysics Data System (ADS)

    Weber, Samuel; Beutel, Jan; Faillettaz, Jérome; Hasler, Andreas; Krautblatter, Michael; Vieli, Andreas

    2017-02-01

    Understanding rock slope kinematics in steep, fractured bedrock permafrost is a challenging task. Recent laboratory studies have provided enhanced understanding of rock fatigue and fracturing in cold environments but were not successfully confirmed by field studies. This study presents a unique time series of fracture kinematics, rock temperatures and environmental conditions at 3500 m a. s. l. on the steep, strongly fractured Hörnligrat of the Matterhorn (Swiss Alps). Thanks to 8 years of continuous data, the longer-term evolution of fracture kinematics in permafrost can be analyzed with an unprecedented level of detail. Evidence for common trends in spatiotemporal pattern of fracture kinematics could be found: a partly reversible seasonal movement can be observed at all locations, with variable amplitudes. In the wider context of rock slope stability assessment, we propose separating reversible (elastic) components of fracture kinematics, caused by thermoelastic strains, from the irreversible (plastic) component due to other processes. A regression analysis between temperature and fracture displacement shows that all instrumented fractures exhibit reversible displacements that dominate fracture kinematics in winter. Furthermore, removing this reversible component from the observed displacement enables us to quantify the irreversible component. From this, a new metric - termed index of irreversibility - is proposed to quantify relative irreversibility of fracture kinematics. This new index can identify periods when fracture displacements are dominated by irreversible processes. For many sensors, irreversible enhanced fracture displacement is observed in summer and its initiation coincides with the onset of positive rock temperatures. This likely indicates thawing-related processes, such as meltwater percolation into fractures, as a forcing mechanism for irreversible displacements. For a few instrumented fractures, irreversible displacements were found at the onset of the freezing period, suggesting that cryogenic processes act as a driving factor through increasing ice pressure. The proposed analysis provides a tool for investigating and better understanding processes related to irreversible kinematics.

  12. Displaced clavicle fractures in adolescents: facts, controversies, and current trends.

    PubMed

    Pandya, Nirav K; Namdari, Surena; Hosalkar, Harish S

    2012-08-01

    There is an increasing trend toward stabilization and fixation of markedly displaced midshaft clavicle fractures in adolescents. Recent studies in the adult literature have shown a greater prevalence of symptomatic malunion, nonunion, and poor functional outcomes after nonsurgical management of displaced fractures. Fixation of displaced midshaft clavicle fractures can restore length and alignment, resulting in shorter time to union. Symptomatic malunion after significantly displaced fractures in adolescents may be more common than previously thought. Adolescents often have high functional demands, and their remodeling potential is limited. Knowledge of bone biology and the effects of shortening, angulation, and rotation on shoulder girdle mechanics is critical in decision making in order to increase the likelihood of optimal results at skeletal maturity. Selection of fixation is dependent on many factors, including fracture type, patient age, skeletal maturity, and surgeon comfort.

  13. Displacement of mandibular fractures: is there a correlation with sensory loss and recovery?

    PubMed

    Scott, R A; Teo, N; Perry, M

    2014-05-01

    Fractures of the mandible are common. However, the correlation between the severity of the fracture and the recovery of any associated inferior dental (ID) nerve injury is still poorly understood. We aimed to examine the relationship between the amount of fracture displacement and how it relates to the recovery of sensation to the lower lip. One hundred and fifty patients requiring treatment of a mandibular fracture (where the fracture passed across the ID canal) were assessed. One hundred were initially assessed in a retrospective double-blinded study. A further 50 patients were then followed up prospectively. Both the maximal displacement of the fracture and the displacement specifically at the ID canal were measured. Sensory recovery, or persistence of numbness, was also recorded for each patient. Although there appeared to be a correlation between increasing displacement at the ID canal and a poorer recovery, there was not a clear relationship between the two, and there were many exceptions. Persistent numbness (>1 year) still occurred in fractures with relatively minimal displacement (≤3mm). Possible reasons for persistent numbness are discussed. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  14. Three lateral divergent or parallel pin fixations for the treatment of displaced supracondylar humerus fractures in children.

    PubMed

    Lee, Young Ho; Lee, Sang Ki; Kim, Byung Sung; Chung, Moon Sang; Baek, Goo Hyun; Gong, Hyun Sik; Lee, Joon Kyu

    2008-06-01

    To evaluate the efficacy of lateral or parallel pin fixation using 3 smooth Kirschner wires (K-wires) or smooth Steinmann pins for the operative management of displaced supracondylar humeral fracture in a consecutive series of children. Sixty-one consecutive displaced or angled supracondylar humeral fractures (Gartland type II or III) in children (mean age, 5 years 6 months) treated by 2 orthopaedic surgeons between 2001 and 2004 according to the following protocol: close reduction under general anesthesia with fluoroscopic guidance and only lateral percutaneous pinning using 3 divergent or parallel Kirschner wires or Steinmann pins. Minimum 2 years' follow-up was done in all 61 patients (range, 2.0-3.3 years). Clinical assessment was obtained at final follow-up using Flynn criteria, and radiologic assessment was obtained using the Baumann and lateral humerocapitellar angles of both arms. Statistical analysis was performed by means of the Student t test (P < 0.05). The study group consisted of 61 patients, of whom 24 (39%) presented with Gartland type II fractures, and the remaining 37 (61%) presented with a type III fracture. A comparison of perioperative and final radiographs shows no loss of reduction of any fracture. There was also no clinically evident cubitus varus, hyperextension, or loss of motion. Eight patients had preoperative nerve palsy. Five of these nerve injuries resolved immediately after surgery, and the other 3 resolved completely within 12 weeks of surgery. After an average of 28 months postoperation, 56 (91.8%) patients had achieved an excellent clinical result, and 5 (8.2%) achieved a good result. There were no iatrogenic nerve palsies, and no patient required additional surgery. One patient had a minor pin-track infection. Our series demonstrates that only 3 lateral divergent or parallel pin fixations are effective and safe for avoiding iatrogenic ulnar nerve injury and are appropriate treatment options for displaced or angled supracondylar humeral fractures in children. Therapeutic study, level III.

  15. Distinct Element Modeling of the Large Block Test

    NASA Astrophysics Data System (ADS)

    Carlson, S. R.; Blair, S. C.; Wagoner, J. L.

    2001-12-01

    The Yucca Mountain Site Characterization Project is investigating Yucca Mountain, Nevada as a potential nuclear waste repository site. As part of this effort, the Large Block, a 3m x 3m x 4.5m rectangular prism of Topopah Spring tuff, was excavated at Fran Ridge near Yucca Mountain. The Large Block was heated to a peak temperature of 145\\deg C along a horizontal plane 2.75m below the top of the block over a period of about one-year. Displacements were measured in three orthogonal directions with an array of six Multiple Point Borehole Extensometers (MPBX) and were numerically simulated in three dimensions with 3DEC, a distinct element code. The distinct element method was chosen to incorporate discrete fractures in the simulations. The model domain was extended 23m below the ground surface and, in the subsurface, 23m outward from each vertical face so that fixed displacement boundary conditions could be applied well away from the heated portion of the block. A single continuum model and three distinct element models, incorporating six to twenty eight mapped fractures, were tested. Two thermal expansion coefficients were tested for the six-fracture model: a higher value taken from laboratory measurements and a lower value from an earlier field test. The MPBX data show that the largest displacements occurred in the upper portion of the block despite the higher temperatures near the center. The continuum model was found to under-predict the MPBX displacements except in the east west direction near the base of the block. The high thermal expansion model over-predicted the MPBX displacements except in the north south direction near the top of the block. The highly fractured model under-predicted most of the MPBX displacements and poorly simulated the cool-down portion of the test. Although no model provided the single best fit to all of the MPBX data, the six and seven fracture models consistently provided good fits and in most cases showed much improvement over the other three models. Both provided particularly good fits to the east west displacements in the upper portion of the block throughout the entire test. This exercise demonstrates that distinct element models can surpass continuum models in their ability to simulate fractured rock mass deformation, but care needs to be taken in the selection of fractures incorporated in the models. *This work was performed under the auspices of the U.S. Department of Energy by the University of California, Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48.

  16. Clavicle fracture with intrathoracic displacement.

    PubMed

    Lohse, Grant R; Lee, Donald H

    2013-08-01

    Clavicle fractures are common, and most are isolated injuries. Injury to the nearby subclavian vessels and brachial plexus have classically been described as potential complications of clavicle fractures. However, in the setting of a substantially displaced clavicle fracture, concomitant thoracic trauma is relatively frequent. Injury to the thorax can be difficult to identify on physical examination, and advanced imaging modalities may be required for diagnosis. The evaluation, workup, and management of a patient with intrathoracic displacement of a clavicle fracture are described. Despite the significant fracture displacement and associated pneumothorax, the injury severity was not clinically obvious. Imaging, including a screening chest radiograph and subsequent axial computed tomography, played an important role in diagnosis and management. The patient underwent successful open reduction and plate fixation. A thoracostomy tube was not required at any point during the hospitalization. The patient recovered uneventfully and returned to full work duty by 3 months postoperatively. Including the current report, only 3 cases of intrathoracic displacement of the clavicle have been published in the English literature. All involved fractures of the middle third of the clavicle. The severity of displacement was not obvious in any patient, and diagnosis was dependent on additional imaging. Given the frequency of associated chest trauma and limitations of physical examination, chest radiography should be considered in the evaluation of patients with substantially displaced clavicle fractures. Copyright 2013, SLACK Incorporated.

  17. Return to sport following clavicle fractures: a systematic review.

    PubMed

    Robertson, G A J; Wood, A M

    2016-09-01

    This review aims to provide information on the return rates and return times to sport following clavicle fractures. A systematic search of Medline, EMBASE, CINAHAL, Cochrane, Web of Science, PEDro, SPORTDiscus, Scopus and Google Scholar was performed using the keywords 'clavicle', 'clavicular', 'fractures', 'athletes', 'sports', 'non-operative', 'conservative', 'operative', 'return to sport'. Twenty-three studies were included: 10 reported on mid-shaft fractures, 14 on lateral fractures. The management principles for athletic patients were to attempt non-operative management for undisplaced fractures to undertake operative intervention for displaced lateral fractures and to recommend operative intervention for displaced mid-shaft fractures. The optimal surgical modality for mid-shaft and lateral clavicle fractures. Operative management of displaced mid-shaft fractures offers improved return rates and times to sport compared to non-operative management. Suture fixation and non-acromio-clavicular joint (ACJ)-spanning plate fixation of displaced lateral fractures show promising results. Future prospective studies should aim to establish the optimal treatment modalities for clavicle fractures. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction.

    PubMed

    Zeng, Canjun; Xing, Weirong; Wu, Zhanglin; Huang, Huajun; Huang, Wenhua

    2016-10-01

    Treatment of acetabular fractures remains one of the most challenging tasks that orthopaedic surgeons face. An accurate assessment of the injuries and preoperative planning are essential for an excellent reduction. The purpose of this study was to evaluate the feasibility, accuracy and effectiveness of performing 3D printing technology and computer-assisted virtual surgical procedures for preoperative planning in acetabular fractures. We hypothesised that more accurate preoperative planning using 3D printing models will reduce the operation time and significantly improve the outcome of acetabular fracture repair. Ten patients with acetabular fractures were recruited prospectively and examined by CT scanning. A 3-D model of each acetabular fracture was reconstructed with MIMICS14.0 software from the DICOM file of the CT data. Bone fragments were moved and rotated to simulate fracture reduction and restore the pelvic integrity with virtual fixation. The computer-assisted 3D image of the reduced acetabula was printed for surgery simulation and plate pre-bending. The postoperative CT scan was performed to compare the consistency of the preoperative planning with the surgical implants by 3D-superimposition in MIMICS14.0, and evaluated by Matta's method. Computer-based pre-operations were precisely mimicked and consistent with the actual operations in all cases. The pre-bent fixation plates had an anatomical shape specifically fit to the individual pelvis without further bending or adjustment at the time of surgery and fracture reductions were significantly improved. Seven out of 10 patients had a displacement of fracture reduction of less than 1mm; 3 cases had a displacement of fracture reduction between 1 and 2mm. The 3D printing technology combined with virtual surgery for acetabular fractures is feasible, accurate, and effective leading to improved patient-specific preoperative planning and outcome of real surgery. The results provide useful technical tips in planning pelvic surgeries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Distal Radius Fractures Do Not Displace following Splint or Cast Removal in the Acute, Postreduction Period: A Prospective, Observational Study.

    PubMed

    Foster, Brock D; Sivasundaram, Lakshmanan; Heckmann, Nathanael; Pannell, William C; Alluri, Ram K; Ghiassi, Alidad

    2017-02-01

    Background  Displacement of distal radius fractures has been previously described in the literature; however, little is known about fracture displacement following splint or cast removal at the initial clinic visit following reduction and immobilization. Purpose  The purpose of this study was to evaluate risk factors for fracture displacement following splint or cast removal and physical examination in the acute postinjury period. Methods  All patients with a closed distal radius fracture who presented to our orthopedic hand clinic within 3 weeks of injury were prospectively enrolled in our study. Standard wrist radiographs were obtained prior to splint or cast removal. A second wrist series was obtained following physical exam and application of immobilization at the end of the clinic visit. Radiographic parameters for displacement were measured by two independent reviewers and included dorsal angulation, radial inclination, articular step-off, radial height, and ulnar variance. Displacement was assessed using predefined, radiographic criteria for displacement. Results  A total of 64 consecutive patients were enrolled over a period of 12 weeks. Of these, 37.5% were classified as operative according to American Academy of Orthopaedic Surgeons guidelines and 37.5% met LaFontaine instability criteria. For each fracture, none of the five measurements exceeded the predefined clinically or statistically significant criteria for displacement. Conclusion  Splint removal in the acute postinjury period did not result in distal radius fracture displacement. Clinicians should feel comfortable removing splints and examining underlying soft tissue in the acute setting for patients with distal radius fractures after closed reduction. Level of Evidence  Level II, prospective comparative study.

  20. Fractures of the proximal fifth metatarsal: percutaneous bicortical fixation.

    PubMed

    Mahajan, Vivek; Chung, Hyun Wook; Suh, Jin Soo

    2011-06-01

    Displaced intraarticular zone I and displaced zone II fractures of the proximal fifth metatarsal bone are frequently complicated by delayed nonunion due to a vascular watershed. Many complications have been reported with the commonly used intramedullary screw fixation for these fractures. The optimal surgical procedure for these fractures has not been determined. All these observations led us to evaluate the effectiveness of percutaneous bicortical screw fixation for treating these fractures. Twenty-three fractures were operatively treated by bicortical screw fixation. All the fractures were evaluated both clinically and radiologically for the healing. All the patients were followed at 2 or 3 week intervals till fracture union. The patients were followed for an average of 22.5 months. Twenty-three fractures healed uneventfully following bicortical fixation, with a mean healing time of 6.3 weeks (range, 4 to 10 weeks). The average American Orthopaedic Foot & Ankle Society (AOFAS) score was 94 (range, 90 to 99). All the patients reported no pain at rest or during athletic activity. We removed the implant in all cases at a mean of 23.2 weeks (range, 18 to 32 weeks). There was no refracture in any of our cases. The current study shows the effectiveness of bicortical screw fixation for displaced intraarticular zone I fractures and displaced zone II fractures. We recommend it as one of the useful techniques for fixation of displaced zone I and II fractures.

  1. Surgical Treatment of Adolescent Clavicle Fractures: Results and Complications.

    PubMed

    McIntosh, Amy L

    2016-06-01

    No level 1 evidence is available to guide the surgical treatment of adolescent clavicle fractures. Adult literature is not applicable as adolescent mid-diaphyseal clavicle fractures do not develop nonunions, and only a small percentage (10% to 20%) are symptomatic from malunions. Current indications for operative fixation are: (1) completely displaced midshaft fracture with shortening of >2 cm; (2) superior displacement with skin tenting and/or an impending open fracture; (3) associated neurovascular injury; (4) open clavicular fracture; and (5) floating shoulder with a completely displaced clavicular fracture. Future large prospective randomized studies will need to be performed to accurately define which adolescent patients will "truly" benefit from surgical intervention.

  2. Temporal evolution of surface rupture deduced from coseismic multi-mode secondary fractures: Insights from the October 8, 2005 (Mw 7.6) Kashmir earthquake, NW Himalaya

    NASA Astrophysics Data System (ADS)

    Sayab, Mohammad; Khan, Muhammad Asif

    2010-10-01

    Detailed rupture-fracture analyses of some of the well-studied earthquakes have revealed that the geometrical arrangement of secondary faults and fractures can be used as a geological tool to understand the temporal evolution of slip produced during the mainshock. The October 8, 2005 Mw 7.6 Kashmir earthquake, NW Himalaya, surface rupture provides an opportunity to study a complex network of secondary fractures developed on the hanging wall of the fault scarp. The main fault scarp is clearly thrust-type, rupture length is ~ 75 ± 5 km and the overall trend of the rupture is NW-SE. We present the results of our detailed structural mapping of secondary faults and fractures at 1:100 scale, on the hanging wall of the southern end of the rupture in the vicinity of the Sar Pain. Secondary ruptures can be broadly classified as two main types, 1) normal faults and, (2) right-lateral strike-slip 'Riedel' fractures. The secondary normal faults are NW-SE striking, with a maximum 3.3 meter vertical displacement and 2.5 meter horizontal displacement. Estimated total horizontal extension across the secondary normal faults is 3.1-3.5%. We propose that the bending-moment and coseismic stress relaxation can explain the formation of secondary normal faults on the hanging wall of the thrust fault. The strike-slip 'Riedel' fractures form distinct sets of tension (T) and shear fractures (R', R, Y) with right-lateral displacement. Field observations revealed that the 'Riedel' fractures (T) cut the secondary normal faults. In addition, there is kinematic incompatibility and magnitude mismatch between the secondary normal faults and strike-slip 'Riedel' fractures. The cross-cutting relationship, geometric and magnitude incoherence implies a temporal evolution of slip from dip- to strike-slip during the mainshock faulting. The interpretation is consistent with the thrust fault plane solution with minor right-lateral strike-slip component.

  3. [Management of disk displacement with condylar fracture].

    PubMed

    Yu, Shi-bin; Li, Zu-bing; Yang, Xue-wen; Zhao, Ji-hong; Dong, Yao-jun

    2003-07-01

    To investigate clinical features of disk displacement during the course of condylar fracture and to explore the techniques of disk reposition and suturation. 32 patients (10 females and 22 males) who had disk displacements with condylar fractures were followed up. Reduction and reposition of the dislocated disks simultaneously with fixation of fractures were performed. 7 patients underwent intermaxillary fixation with elastic bands for 1 to 2 weeks. The occlusions were satisfactory in all cases but one for the reason of ramus height loss. No TMJ symptom was found when examined 3 months post operation. Anterior disk displacements were most occurred with high condylar process fractures. Surgical reposition and suturation of disk play an important role for the later TMJ-function.

  4. Surgery versus conservative treatment in patients with type A distal radius fractures, a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Fractures of the distal radius are common and account for an estimated 17% of all fractures diagnosed. Two-thirds of these fractures are displaced and require reduction. Although distal radius fractures, especially extra-articular fractures, are considered to be relatively harmless, inadequate treatment may result in impaired function of the wrist. Initial treatment according to Dutch guidelines consists of closed reduction and plaster immobilisation. If fracture redisplacement occurs, surgical treatment is recommended. Recently, the use of volar locking plates has become more popular. The aim of this study is to compare the functional outcome following surgical reduction and fixation with a volar locking plate with the functional outcome following closed reduction and plaster immobilisation in patients with displaced extra-articular distal radius fractures. Design This single blinded randomised controlled trial will randomise between open reduction and internal fixation with a volar locking plate (intervention group) and closed reduction followed by plaster immobilisation (control group). The study population will consist of all consecutive adult patients who are diagnosed with a displaced extra-articular distal radius fracture, which has been adequately reduced at the Emergency Department. The primary outcome (functional outcome) will be assessed by means of the Disability Arm Shoulder Hand Score (DASH). Secondary outcomes comprise the Patient-Rated Wrist Evaluation score (PRWE), quality of life, pain, range of motion, radiological parameters, complications and cross-overs. Since the treatment allocated involves a surgical procedure, randomisation status will not be blinded. However, the researcher assessing the outcome at one year will be unaware of the treatment allocation. In total, 90 patients will be included and this trial will require an estimated time of two years to complete and will be conducted in the Academic Medical Centre Amsterdam and its partners of the regional trauma care network. Dicussion Ideally, patients would be randomised before any kind of treatment has been commenced. However, we deem it not patient-friendly to approach possible participants before adequate reduction has been obtained. Trial registration This study is registered at the Netherlands Trial Register (NTR3113) and was granted permission by the Medical Ethical Review Committee of the Academic Medical Centre on 01-10-2012. PMID:24642190

  5. [POKING REDUCTION TREATMENT OF DISPLACED SCAPULAR NECK FRACTURE WITH SHOULDER ARTHROSCOPY-ASSISTED SURGERY].

    PubMed

    Qu, Feng; Yuan, Bangtuo; Qi, Wei; Wang, Junliang; Shen, Xuezhen; Wang, Jiangtao; Zhao, Gang; Liu, Yujie

    2014-07-01

    To discuss the effectiveness of Poking reduction with shoulder arthroscopy-assisted surgery for displaced scapular neck fracture. Between January 2009 and January 2012, 9 cases of displaced scapular neck fracture underwent shoulder arthroscopy-assisted surgery for Poking reduction treatment. Of 9 cases, 6 were men, and 3 were women, aged 21-54 years (mean, 39 years). The causes were traffic accident injury in 7 cases, falling injury from height in 1 case, and hurt injury in 1 case. The shoulder abduction, flexion, and external rotation were obviously limited. X-ray films showed all cases had obvious displaced scapular neck fracture. Three-dimensional reconstruction of CT showed a grossly displaced of fracture. The time of injury to surgery was 4-27 days (mean, 11 days). Patients obtained healing of incision by first intension, without infection, neurovascular injury, or other surgery-related complications. All patients were followed up 19- 31 months (mean, 23 months). X-ray films showed scapular neck fractures healed from 7 to 11 weeks (mean, 8 weeks). At last follow-up, the shoulder abduction, flexion, and external rotation activity were improved significantly when compared with ones at preoperation (P < 0.05); the shoulder Constant score, American Shoulder and Elbow Surgenos (ASES) score, and Rowe score were significantly better than preoperative scores (P < 0.05). The reduction of displaced scapular neck fracture is necessary, and arthroscopic Poking reduction and fixation for displaced scapular neck fracture can reconstruct the shoulder stability and reduce complications.

  6. Influence of mesh density, cortical thickness and material properties on human rib fracture prediction.

    PubMed

    Li, Zuoping; Kindig, Matthew W; Subit, Damien; Kent, Richard W

    2010-11-01

    The purpose of this paper was to investigate the sensitivity of the structural responses and bone fractures of the ribs to mesh density, cortical thickness, and material properties so as to provide guidelines for the development of finite element (FE) thorax models used in impact biomechanics. Subject-specific FE models of the second, fourth, sixth and tenth ribs were developed to reproduce dynamic failure experiments. Sensitivity studies were then conducted to quantify the effects of variations in mesh density, cortical thickness, and material parameters on the model-predicted reaction force-displacement relationship, cortical strains, and bone fracture locations for all four ribs. Overall, it was demonstrated that rib FE models consisting of 2000-3000 trabecular hexahedral elements (weighted element length 2-3mm) and associated quadrilateral cortical shell elements with variable thickness more closely predicted the rib structural responses and bone fracture force-failure displacement relationships observed in the experiments (except the fracture locations), compared to models with constant cortical thickness. Further increases in mesh density increased computational cost but did not markedly improve model predictions. A ±30% change in the major material parameters of cortical bone lead to a -16.7 to 33.3% change in fracture displacement and -22.5 to +19.1% change in the fracture force. The results in this study suggest that human rib structural responses can be modeled in an accurate and computationally efficient way using (a) a coarse mesh of 2000-3000 solid elements, (b) cortical shells elements with variable thickness distribution and (c) a rate-dependent elastic-plastic material model. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Anatomically precontoured LCP for delayed union of a medial third clavicle fracture. Case report with review of the literature.

    PubMed

    Siebenlist, S; Sandmann, G; Kirchhoff, C; Biberthaler, P; Neumaier, M

    2013-01-01

    Fractures of the medial clavicle third are rare injuries. Even in case of significant fracture displacement, their therapeutic management has been nonoperative. Recently, surgical intervention has become mandatory for displaced fractures types to prevent non-union and functional complaints, but the optimal operative strategy is being discussed controversially. We describe the case of a 63-year-old male patient with a significantly displaced medial clavicle fracture after failed conservative treatment resulting in restricted, painful shoulder function. The patient underwent open reduction and osteosynthesis with an anatomically precontoured locking compression plate (LCP). One year after surgery the patient is free of complaints and has returned to his preinjury activity level without any functional restrictions. As a not yet reported operative approach, anatomically preshaped locking plating seems to be an effective fixation method for displaced fractures of the medial clavicle third. The operative management is described in detail and discussed with the current literature. Based on the presented case, we underline the statement that displaced medial clavicle fractures should be surgically addressed to avoid late damage.

  8. Radiological study of the secondary reduction effect of early functional exercise on displaced intra-articular calcaneal fractures after internal compression fixation.

    PubMed

    Chen, Wei; Liu, Bo; Lv, Hongzhi; Su, Yanling; Chen, Xiao; Zhu, Yanbin; Du, Chenguang; Zhang, Xiaolin; Zhang, Yingze

    2017-09-01

    Early post-operative exercise and weight-bearing activities are found to improve the functional recovery of patients with displaced intra-articular calcaneal fractures (DIACFs). We hypothesized that early functional exercise after surgery might have a secondary reduction effect on the subtalar joint, in particular the smaller fracture fragments that were not fixed firmly. A prospective study was conducted to verify this hypothesis. From December 2012 to September 2013, patients with unilateral DIACFs were enrolled and received a treatment consisting of percutaneous leverage and minimally invasive fixation. After surgery, patients in the study group started exercising on days two to three, using partial weight bearing starting week three, and full weight bearing starting week 12. Patients in the control group followed a conventional post-operative protocol of partial weight bearing after week six and full weight bearing after the bone healed. Computed tomography (CT) scanning was performed at post-operative day one, week four, week eight, and week 12 to reconstruct coronal, sagittal, and axial images, on which the maximal residual displacements of the fractures were measured. Function was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring scale at the 12th post-operative month. Twenty-eight patients in the study group and 32 in the control group were followed up for more than 12 months; their data were collected and used for the final analysis. Repeated-measures analysis of variance (ANOVA) of the maximal residual displacements of the fracture measured on CT images revealed significant differences between the study and the control groups. There were interaction effects between group and time point. Except for the first time point, the differences between the groups at all studied time points were significant. In the study group, the differences between all studied time points were significant. Strong correlations were observed between the AOFAS score at post-operative month 12 and the maximal residual displacement of the fractures on the CT images at postoperative week 12. Early functional exercise and weight bearing activity can smooth and shape the subtalar joint and reduce the residual displacement of the articular surface, improving functional recovery of the affected foot. Therefore, early rehabilitation functional exercise can be recommended in clinical practice.

  9. Fracture hydromechanical response measured by fiber optic distributed acoustic sensing at milliHertz frequencies

    NASA Astrophysics Data System (ADS)

    Becker, M. W.; Ciervo, C.; Cole, M.; Coleman, T.; Mondanos, M.

    2017-07-01

    A new method of measuring dynamic strain in boreholes was used to record fracture displacement in response to head oscillation. Fiber optic distributed acoustic sensing (DAS) was used to measure strain at mHz frequencies, rather than the Hz to kHz frequencies typical for seismic and acoustic monitoring. Fiber optic cable was mechanically coupled to the wall of a borehole drilled into fractured crystalline bedrock. Oscillating hydraulic signals were applied at a companion borehole 30 m away. The DAS instrument measured fracture displacement at frequencies of less than 1 mHz and amplitudes of less than 1 nm, in response to fluid pressure changes of less 20 Pa (2 mm H2O). Displacement was linearly related to the log of effective stress, a relationship typically explained by the effect of self-affine fracture roughness on fracture closure. These results imply that fracture roughness affects closure even when displacement is a million times smaller than the fracture aperture.

  10. A retrospective cohort study of displaced segmental radial head fractures: is 2 mm of articular displacement an indication for surgery?

    PubMed

    Furey, Matthew J; Sheps, David M; White, Neil J; Hildebrand, Kevin A

    2013-05-01

    Many investigators agree that 2 mm of articular displacement is a reasonable indication for open reduction and internal fixation of Mason type II fractures of the radial head. However, there is no evidence to support that this degree of articular displacement is predictive of poor outcomes in conservatively treated fractures. We hypothesized there would be no difference between conservatively treated radial head fractures with greater 2 mm of displacement and those with less than 2 mm of displacement in terms of patient-reported or clinical outcomes. We reviewed databases of all radial head fractures in our region. The primary outcomes were the Patient-Rated Elbow Evaluation and Disabilities of the Arm, Shoulder and Hand questionnaires. Secondary outcomes included radiologic radiocapitellar arthritis and range of motion (ROM) at follow-up. Postinjury treatment protocols, as well as patient factors, were examined for their effects on outcome. The results showed no significant difference in any outcome for conservatively treated radial head fractures with 2 mm (P = .8) or even 3 mm (P = .6) of articular displacement over a mean follow-up of 4.4 years. Early ROM and physiotherapy showed no significant differences in any outcome measure. Dominant hand injury showed no significant difference in patient-reported outcomes; however, ROM was significantly decreased on examination. This retrospective review suggests that fracture displacement of 2 to 3 mm is not necessarily an indication for surgical fixation in isolated fractures of the radial head. In addition, it appears that postinjury ROM/physiotherapy does not play a large role in improving patient outcome. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. Teeth in the Line of Fracture: To Retain or Remove?

    PubMed Central

    Samson, Jimson; John, Reena; Jayakumar, Shalini

    2010-01-01

    The purpose of this study was to analyze mandibular fracture site, relationship of the fracture line to the periodontium, vitality of teeth, displacement of the fracture segments and their implications, and determine whether to retain or remove the teeth in the fracture line. Fifty patients with 62 fractures were involved in this study. An electric pulp tester was used to measure the pulpal response. The degree of fracture displacement and the relationship of the fracture line to the periodontium were evaluated using panoramic radiographs. Fractures of the parasymphysis region constituted a majority of 60.87% in the gross displacement category. Four of 50 patients showed no response presurgically and minimal response postoperatively on pulp vitality testing. Patients with teeth in the fracture line showing no response on pulp vitality testing should be advised extraction to avoid further complications. PMID:22132255

  12. Effects of fracture surface roughness and shear displacement on geometrical and hydraulic properties of three-dimensional crossed rock fracture models

    NASA Astrophysics Data System (ADS)

    Huang, Na; Liu, Richeng; Jiang, Yujing; Li, Bo; Yu, Liyuan

    2018-03-01

    While shear-flow behavior through fractured media has been so far studied at single fracture scale, a numerical analysis of the shear effect on the hydraulic response of 3D crossed fracture model is presented. The analysis was based on a series of crossed fracture models, in which the effects of fracture surface roughness and shear displacement were considered. The rough fracture surfaces were generated using the modified successive random additions (SRA) algorithm. The shear displacement was applied on one fracture, and at the same time another fracture shifted along with the upper and lower surfaces of the sheared fracture. The simulation results reveal the development and variation of preferential flow paths through the model during the shear, accompanied by the change of the flow rate ratios between two flow planes at the outlet boundary. The average contact area accounts for approximately 5-27% of the fracture planes during shear, but the actual calculated flow area is about 38-55% of the fracture planes, which is much smaller than the noncontact area. The equivalent permeability will either increase or decrease as shear displacement increases from 0 to 4 mm, depending on the aperture distribution of intersection part between two fractures. When the shear displacement continuously increases by up to 20 mm, the equivalent permeability increases sharply first, and then keeps increasing with a lower gradient. The equivalent permeability of rough fractured model is about 26-80% of that calculated from the parallel plate model, and the equivalent permeability in the direction perpendicular to shear direction is approximately 1.31-3.67 times larger than that in the direction parallel to shear direction. These results can provide a fundamental understanding of fluid flow through crossed fracture model under shear.

  13. Fracture resistance of a TiB2 particle/SiC matrix composite at elevated temperature

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.; Seshadri, Srinivasa G.

    1988-01-01

    The fracture resistance of a comercial TiB2 particle/SiC matrix composite was evaluated at temperatures ranging from 20 to 1400 C. A laser interferometric strain gauge (LISG) was used to continuously monitor the crack mouth opening displacement (CMOD) of the chevron-notched and straight-notched, three-point bend specimens used. Crack growth resistance curves (R-curves) were determined from the load versus displacement curves and displacement calibrations. Fracture toughness, work-of-fracture, and R-curve levels were found to decrease with increasing temperature. Microstructure, fracture surface, and oxidation coat were examined to explain the fracture behavior.

  14. Fracture resistance of a TiB2 particle/SiC matrix composite at elevated temperature

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.; Seshadri, Srinivasa G.

    1989-01-01

    The fracture resistance of a commercial TiB2 particle/SiC matrix composite was evaluated at temperatures ranging from 20 to 1400 C. A laser interferometric strain gauge (LiSG) was used to continuously monitor the crack mouth opening displacement (CMOD) of the chevron-notched and straight-notched, three-point bend specimens used. Crack growth resistance curves (R-curves) were determined from the load versus displacement curves and displacement calibrations. Fracture toughness, work-of-fracture, and R-curve levels were found to decrease with increasing temperature. Microstructure, fracture surface, and oxidation coat were examined to explain the fracture behavior.

  15. Training improves interobserver reliability for the diagnosis of scaphoid fracture displacement.

    PubMed

    Buijze, Geert A; Guitton, Thierry G; van Dijk, C Niek; Ring, David

    2012-07-01

    The diagnosis of displacement in scaphoid fractures is notorious for poor interobserver reliability. We tested whether training can improve interobserver reliability and sensitivity, specificity, and accuracy for the diagnosis of scaphoid fracture displacement on radiographs and CT scans. Sixty-four orthopaedic surgeons rated a set of radiographs and CT scans of 10 displaced and 10 nondisplaced scaphoid fractures for the presence of displacement, using a web-based rating application. Before rating, observers were randomized to a training group (34 observers) and a nontraining group (30 observers). The training group received an online training module before the rating session, and the nontraining group did not. Interobserver reliability for training and nontraining was assessed by Siegel's multirater kappa and the Z-test was used to test for significance. There was a small, but significant difference in the interobserver reliability for displacement ratings in favor of the training group compared with the nontraining group. Ratings of radiographs and CT scans combined resulted in moderate agreement for both groups. The average sensitivity, specificity, and accuracy of diagnosing displacement of scaphoid fractures were, respectively, 83%, 85%, and 84% for the nontraining group and 87%, 86%, and 87% for the training group. Assuming a 5% prevalence of fracture displacement, the positive predictive value was 0.23 in the nontraining group and 0.25 in the training group. The negative predictive value was 0.99 in both groups. Our results suggest training can improve interobserver reliability and sensitivity, specificity and accuracy for the diagnosis of scaphoid fracture displacement, but the improvements are slight. These findings are encouraging for future research regarding interobserver variation and how to reduce it further.

  16. Upright vs. Supine Radiographs of Clavicle Fractures: Does Positioning Matter?

    PubMed Central

    Backus, Jonathon D; Merriman, David J; McAndrew, Christopher M; Gardner, Michael J; Ricci, William M

    2014-01-01

    Objectives To determine if clavicle fracture displacement and shortening are different between upright and supine radiographic examinations. Design Combined retrospective and prospective comparative study. Setting Level I Trauma Center Patients Forty-six patients (mean age 49 years, range 24–89 years) with an acute clavicle fracture were evaluated. Intervention Standardized clavicle radiographs were obtained in both supine and upright positions for each patient. Displacement and shortening were measured and compared between the two positions. Main Outcomes Measurements One resident and three traumatologists classified the fractures and measured displacement and shortening. Data was aggregated and compared to ensure reliability with a two-way mixed intraclass correlation (ICC). Results Fracture displacement was significantly greater when measured from upright radiographs (15.9±8.9mm) than from supine radiographs (8.4±6.6mm, p<0.001), representing an 89% increase in displacement with upright positioning. Forty-one percent of patients had greater than 100% displacement on upright, but not on supine radiographs. Compared to the uninjured side, 3.0±10.7mm of shortening was noted on upright radiographs and 1.3±9.5mm of lengthening on supine radiographs (p<0.001). The ICC was 0.82 (95% CI: 0.73–0.89) for OTA fracture classification, 0.81 (95% CI: 0.75–0.87) for vertical displacement, and 0.92 (95% CI: 0.88–0.95) for injured clavicle length, demonstrating very high agreement among evaluators. Conclusions Increased fracture displacement and shortening was observed on upright compared to supine radiographs. This suggests that upright radiographs may better demonstrate clavicle displacement and predict the position at healing if nonoperative treatment is selected. PMID:24740113

  17. Clavicle Shaft Fractures in Adolescents.

    PubMed

    Yang, Scott; Andras, Lindsay

    2017-01-01

    Midshaft clavicle fractures in adolescents are common. Recent literature in adults fractures favors open reduction and plate fixation for significantly displaced and/or shortened midshaft clavicle fractures, although whether this applies to adolescents remains debatable. This article reviews the current literature and controversy in the management of displaced adolescent clavicle fractures. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    PubMed

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  19. [Osteosynthesis by tension band wiring of displaced fractures of the olecranon].

    PubMed

    Doursounian, L; Prevot, O; Touzard, R C

    1994-01-01

    Fifty-two displaced olecranon fractures in adults were treated over a 5-year period. Minimum follow-up was 6 months. Forty-eight fractures were operated and 38 were treated by tension band wiring technique. This technique, applied for all types of fractures, gave good functional results in 33 cases (87%) and fair functional results in 5 cases. Complications include 1 pseudarthrosis, 2 loss of reduction, 2 transient tourniquet palsy and 13 skin problems due to wire protrusion. Tension band wiring is a simple safe and effective technique for displaced olecranon fractures but often requires K-wire removal.

  20. A Review of the Proposed KIsi Offset-Secant Method for Size-Insensitive Linear-Elastic Fracture Toughness Evaluation

    NASA Technical Reports Server (NTRS)

    James, Mark; Wells, Doug; Allen, Phillip; Wallin, Kim

    2017-01-01

    Recently proposed modifications to ASTM E399 would provide a new size-insensitive approach to analyzing the force-displacement test record. The proposed size-insensitive linear-elastic fracture toughness, KIsi, targets a consistent 0.5mm crack extension for all specimen sizes by using an offset secant that is a function of the specimen ligament length. The KIsi evaluation also removes the Pmax/PQ criterion and increases the allowable specimen deformation. These latter two changes allow more plasticity at the crack tip, prompting the review undertaken in this work to ensure the validity of this new interpretation of the force-displacement curve. This paper provides a brief review of the proposed KIsi methodology and summarizes a finite element study into the effects of increased crack tip plasticity on the method given the allowance for additional specimen deformation. The study has two primary points of investigation: the effect of crack tip plasticity on compliance change in the force-displacement record and the continued validity of linear-elastic fracture mechanics to describe the crack front conditions. The analytical study illustrates that linear-elastic fracture mechanics assumptions remain valid at the increased deformation limit; however, the influence of plasticity on the compliance change in the test record is problematic. A proposed revision to the validity criteria for the KIsi test method is briefly discussed.

  1. Part II: arthroscopic treatment of tibial plateau fractures: intercondylar eminence avulsion fractures.

    PubMed

    Lubowitz, James H; Elson, Wylie S; Guttmann, Dan

    2005-01-01

    Arthroscopic reduction and internal fixation (ARIF) of tibial intercondylar eminence fractures is the emerging state-of-the-art. ARIF is recommended for displaced type III fractures and should be considered for all cases of displaced type II fractures. Fractures without displacement after closed reduction require careful evaluation to rule out meniscal entrapment. Subjective results of ARIF are uniformly excellent, despite reports of objective anteroposterior laxity. Early range-of-motion exercises are essential to prevent loss of extension. Repair using nonabsorbable suture fixation, when of adequate strength to allow early range-of-motion, has the advantages of eliminating the risks of comminution of the fracture fragment, posterior neurovascular injury, and need for hardware removal, compared with ARIF using screws.

  2. Temporal variation of applied inter fragmentary displacement at a bone fracture in harmony with maturation of the fracture callus.

    PubMed

    Gardner, T N; Evans, M; Simpson, H

    1998-09-01

    The amplitude of inter fragmentary displacement in long bone fractures greatly influences the pattern and speed of healing. Unfortunately, the amplitude of natural cyclical displacement arising from patient activity is random because of the inherent flexibility of fixation devices under natural loading. Although fixators may be designed to control the amplitude of this displacement, the amplitudes most beneficial to healing have not been determined. Furthermore, the appropriate amplitude must vary during healing as the reparative tissue (callus) progresses histologically and stiffens during maturation. In this study on an experimental fracture, the amplitude of applied cyclical displacement is varied during healing to correspond with the inverse of the callus stiffness versus time curve. In vivo mechanical stiffness tests on the callus indicate that the end point of the fixation period is achieved more rapidly than with a constant level of applied displacement.

  3. Pelvic trauma with displaced sacral fractures: functional outcome at one year.

    PubMed

    Tötterman, Anna; Glott, Thomas; Søberg, Helene Lundgaard; Madsen, Jan Erik; Røise, Olav

    2007-06-01

    A prospective single-cohort study of 31 patients surgically treated for pelvic injuries with displaced sacral fractures. To describe the medium term functional outcome in unstable sacral fractures. Displaced sacral fractures pose a special challenge in orthopedic surgery due to the high rate of associated injuries. Little information is available on the medium-term functional outcome of patients with injuries which include unstable sacral fractures. We examined 31 patients with displaced sacral fractures having 10 mm or more displacement, 1 year (mean, 1.4 years; range, 1.0-2.5 years) after injury. Data from a previous study were supplemented with functional outcome measures (work status, independence in ADL, and SF-36). An association between outcome and tested variables was sought. Fifteen months after injury, 65% of the patients had regained their independence in functions pertaining to daily activities; 33% had returned to work. All dimensions of perceived health were affected. Polytrauma and impairments relative to voiding and sexual function had a detrimental effect on outcome. Fracture characteristics were not predictive of poor outcome. Although the majority of patients achieved independent living, medium-term follow-up indicated significant residual disability. The complex nature of these fractures and the associated injuries should be considered in the rehabilitation of these patients.

  4. Overtreatment of displaced midshaft clavicle fractures

    PubMed Central

    Ban, Ilija; Nowak, Jan; Virtanen, Kaisa; Troelsen, Anders

    2016-01-01

    Background and purpose The best treatment for displaced clavicle fractures has been debated for decades. Operative treatment has become more common. However, several randomized trials comparing non-operative and operative treatment have not shown any compelling evidence in favor of surgery. We identified the preferred treatment of displaced midshaft clavicle fractures at public hospitals in 3 countries in Scandinavia. Patients and methods A purpose-made multiple-choice questionnaire in English was sent to all public hospitals in Denmark, Sweden, and Finland. This was addressed to the orthopedic surgeon responsible for treatment of clavicle fractures, and completed questionnaires were obtained from 85 of 118 hospitals. Results In the 3 countries, 69 of the 85 hospitals that responded would treat displaced clavicle fractures operatively. Clear criteria for treatment allocation were used at 58 of the hospitals, with the remaining 27 using individual assessment in collaboration with the patient. Precontoured locking plates were mostly used, placed either superiorly (64/85) or anteriorly (10/85). Interpretation Displaced midshaft clavicle fractures are mainly treated operatively in Sweden, Denmark, and Finland. This treatment is not supported by compelling evidence. PMID:27225678

  5. Overtreatment of displaced midshaft clavicle fractures.

    PubMed

    Ban, Ilija; Nowak, Jan; Virtanen, Kaisa; Troelsen, Anders

    2016-12-01

    Background and purpose - The best treatment for displaced clavicle fractures has been debated for decades. Operative treatment has become more common. However, several randomized trials comparing non-operative and operative treatment have not shown any compelling evidence in favor of surgery. We identified the preferred treatment of displaced midshaft clavicle fractures at public hospitals in 3 countries in Scandinavia. Patients and methods - A purpose-made multiple-choice questionnaire in English was sent to all public hospitals in Denmark, Sweden, and Finland. This was addressed to the orthopedic surgeon responsible for treatment of clavicle fractures, and completed questionnaires were obtained from 85 of 118 hospitals. Results - In the 3 countries, 69 of the 85 hospitals that responded would treat displaced clavicle fractures operatively. Clear criteria for treatment allocation were used at 58 of the hospitals, with the remaining 27 using individual assessment in collaboration with the patient. Precontoured locking plates were mostly used, placed either superiorly (64/85) or anteriorly (10/85). Interpretation - Displaced midshaft clavicle fractures are mainly treated operatively in Sweden, Denmark, and Finland. This treatment is not supported by compelling evidence.

  6. Primary drainage in geological fractures: Effects of aperture variability and wettability

    NASA Astrophysics Data System (ADS)

    Yang, Z.; Méheust, Y.; Neuweiler, I.

    2017-12-01

    Understanding and controlling fluid-fluid displacement in porous and fractured media is a key asset for many practical applications, such as the geological storage of CO2, hydrocarbon recovery, groundwater remediation, etc. We numerically investigate fluid-fluid displacement in rough-walled fractures with a focus on the combined effect of wettability, the viscous contrast between the two fluids, and fracture surface topography on drainage patterns and interface growth. A model has been developed to simulate the dynamic displacement of one fluid by another immiscible one in a rough geological fracture; the model takes both capillary and viscous forces into account. Capillary pressures at the fluid-fluid interface are calculated based on the Young-Laplace equation using the two principal curvatures (aperture-induced curvature and in-plane curvature) [1], while viscous forces are calculated by continuously solving the fluid pressure field in the fracture. The aperture field of a fracture is represented by a spatially correlated random field, with a power spectral density of the fracture wall topographies scaling as a power law, and a cutoff wave-length above which the Fourier modes of the two walls are identical [2]. We consider flow scenarios with both rectangular and radial configurations. Results show that the model is able to produce displacement patterns of compact displacement, capillary fingering, and viscous fingering, as well as the transitions between them. Both reducing the aperture variability and increasing the contact angle (from drainage to weak imbibition) can stabilize the displacement due to the influence of the in-plane curvature, an effect analogous to that of the cooperative pore filling in porous media. These results suggest that for geometries typical of geological fractures we can extend the phase diagram in the parameter space of capillary number and mobility ratio by another dimension to take into account the combined effect of wettability and fracture aperture topography. References: [1] Yang, Z. et al. (2012), A generalized approach for estimation of in-plane curvature in invasion percolation models for drainage in fractures. Wat. Resour. Res., 48(9), W09507. [2] Yang, Z. et al. (2016), Fluid trapping during capillary displacement in fractures. Adv. Water Resour., 95, 264-275.

  7. [Correlation analysis between residual displacement and hip function after reconstruction of acetabular fractures].

    PubMed

    Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu

    2012-03-01

    To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the worse the hip function is.

  8. Effects of aperture variability and wettability on immiscible displacement in fractures

    NASA Astrophysics Data System (ADS)

    Yang, Zhibing; Méheust, Yves; Neuweiler, Insa

    2017-04-01

    Fluid-fluid displacement in porous and fractured media is an important process. Understanding and controlling this process is key to many practical applications, such as hydrocarbon recovery, geological storage of CO2, groundwater remediation, etc. Here, we numerically study fluid-fluid displacement in rough-walled fractures. We focus on the combined effect of wettability and fracture surface topography on displacement patterns and interface growth. We develop a novel numerical model to simulate dynamic fluid invasion under the influence of capillary and viscous forces. The capillary force is calculated using the two principal curvatures (aperture-induced curvature and in-plane curvature) at the fluid-fluid interface, and the viscous force is taken into account by solving the fluid pressure distribution. The aperture field of a fracture is represented by a spatially correlated random field, which is described by a power spectrum for the fracture wall topography and a cutoff wave-length. We numerically produce displacement patterns ranging from stable displacement, capillary fingering, and viscous fingering, as well as the transitions between them. We show that both reducing the aperture variability and increasing the contact angle (from drainage to weak imbibition) stabilize the displacement due to the influence of the in-plane curvature, an effect analogous to that of the cooperative pore filling in porous media. Implications of these results will be discussed.

  9. Closed reduction of displaced or dislocated mandibular condyle fractures in children using threaded Kirschner wire and external rubber traction.

    PubMed

    Kim, J H; Nam, D H

    2015-10-01

    Most surgeons agree that closed treatment provides the best results for condylar fractures in children. Nevertheless, treatment of the paediatric mandibular condyle fracture that is severely displaced or dislocated is controversial. The purpose of this study was to investigate the long-term clinical and radiological outcomes following the treatment of displaced or dislocated condylar fractures in children using threaded Kirschner wire and external rubber traction. This procedure can strengthen the advantage of closed reduction and make up for the shortcomings of open reduction. From March 1, 2005 to December 25, 2011, 11 children aged between 4 and 12 years with displaced or dislocated mandibular condyle fractures were treated using threaded Kirschner wire and external rubber traction under portable C-arm fluoroscopy. All patients had unilateral displaced or dislocated condylar fractures. The follow-up period ranged from 24 to 42 months (mean 29.3 months). Normal occlusion and pain-free function of the temporomandibular joint, without deviation or limitation of jaw opening, was achieved in all patients. This closed reduction technique in displaced or dislocated condylar fractures in children offers a reliable solution in preventing the unfavourable sequelae of closed treatment and the open technique, such as altered morphology, functional disturbances, and facial nerve damage. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Pore-level influence of micro-fracture parameters on visco-capillary behavior of two-phase displacements in porous media

    NASA Astrophysics Data System (ADS)

    Rokhforouz, M. R.; Akhlaghi Amiri, H. A.

    2018-03-01

    In this work, coupled Cahn-Hilliard phase field and Navier-Stokes equations were solved using finite element method to address the effects of micro-fracture and its characterizations on water-oil displacements in a heterogeneous porous medium. Sensitivity studies at a wide range of viscosity ratios (M) and capillary numbers (Ca), and the resultant log Ca-log M stability phase diagram, revealed that in both media, with/without fracture, the three regimes of viscous fingering, capillary fingering and stable displacement similarly occur. However, presence of the fracture caused water channeling phenomenon which resulted in reduction of the number of active fingers and hence the final oil recovery factor. At high Ca (especially in the stable regime, with log Ca ≥ -2.5 and log M ≥ 0), recovery factor for the fractured medium was relatively identical with the non-fractured one. At log M ≥ 0, the fracture was fully swept, but flow instabilities were observed inside the fracture at lower M values, especially for log Ca > -4.6. In the case of the fractured medium at log Ca = -4.6 and log M = 0 (capillary dominant flow), it is observed that the primary breakthrough took place by a finger progressed through the matrix, not those channeled through the fracture. Geometrical properties of the fracture, including length, aperture and orientation, highly affected both displacement profile and efficiency. The fracture length inversely influenced the oil recovery factor. It was observed that there is a critical fracture width (almost half of the medium average pore diameter) at which the recovery factor of the medium during displacement is minimum, compared to the media having thinner and thicker fractures. Minor channeling effect in the media with thinner fracture and larger fracture swept volume as well as high fracture/matrix cross flow in the media with thicker fracture were detected as the main cause of this non-monotonic behavior. In the models with thick fractures (with the thickness higher than the average pore diameter), considerable trapped oil volumes were observed inside the fracture at low M values. The fracture orientation had the most impressive effect on oil recovery compared to the other studied parameters; where the oil recovery factor incremented more than 20% as the fracture rotated 90° from flow direction. Due to the dominant effect of the channeling phenomenon, the change in the medium wettability from slightly oil-wet to slightly water-wet, did not considerably affect the displacement profile in the fractured medium. However, oil recovery factor increased as the medium became more water-wet. The fracture area was fully swept by the injected water in the oil-wet and neutral-wet media. However, flow instabilities were observed inside the fracture of the water-wet medium due to counter-current imbibition between fracture/matrix. Micro-scale mechanisms of pore doublet effect, interface coalesce, snap-off and reverse movements were captured during the studied unstable displacements.

  11. Investigation of translaminar fracture in fibrereinforced composite laminates---applicability of linear elastic fracture mechanics and cohesive-zone model

    NASA Astrophysics Data System (ADS)

    Hou, Fang

    With the extensive application of fiber-reinforced composite laminates in industry, research on the fracture mechanisms of this type of materials have drawn more and more attentions. A variety of fracture theories and models have been developed. Among them, the linear elastic fracture mechanics (LEFM) and cohesive-zone model (CZM) are two widely-accepted fracture models, which have already shown applicability in the fracture analysis of fiber-reinforced composite laminates. However, there remain challenges which prevent further applications of the two fracture models, such as the experimental measurement of fracture resistance. This dissertation primarily focused on the study of the applicability of LEFM and CZM for the fracture analysis of translaminar fracture in fibre-reinforced composite laminates. The research for each fracture model consisted of two sections: the analytical characterization of crack-tip fields and the experimental measurement of fracture resistance parameters. In the study of LEFM, an experimental investigation based on full-field crack-tip displacement measurements was carried out as a way to characterize the subcritical and steady-state crack advances in translaminar fracture of fiber-reinforced composite laminates. Here, the fiber-reinforced composite laminates were approximated as anisotropic solids. The experimental investigation relied on the LEFM theory with a modification with respect to the material anisotropy. Firstly, the full-field crack-tip displacement fields were measured by Digital Image Correlation (DIC). Then two methods, separately based on the stress intensity approach and the energy approach, were developed to measure the crack-tip field parameters from crack-tip displacement fields. The studied crack-tip field parameters included the stress intensity factor, energy release rate and effective crack length. Moreover, the crack-growth resistance curves (R-curves) were constructed with the measured crack-tip field parameters. In addition, an error analysis was carried out with an emphasis on the influence of out-of-plane rotation of specimen. In the study of CZM, two analytical inverse methods, namely the field projection method (FPM) and the separable nonlinear least-squares method, were developed for the extraction of cohesive fracture properties from crack-tip full-field displacements. Firstly, analytical characterizations of the elastic fields around a crack-tip cohesive zone and the cohesive variables within the cohesive zone were derived in terms of an eigenfunction expansion. Then both of the inverse methods were developed based on the analytical characterization. With the analytical inverse methods, the cohesive-zone law (CZL), cohesive-zone size and position can be inversely computed from the cohesive-crack-tip displacement fields. In the study, comprehensive numerical tests were carried out to investigate the applicability and robustness of two inverse methods. From the numerical tests, it was found that the field projection method was very sensitive to noise and thus had limited applicability in practice. On the other hand, the separable nonlinear least-squares method was found to be more noise-resistant and less ill-conditioned. Subsequently, the applicability of separable nonlinear least-squares method was validated with the same translaminar fracture experiment for the study of LEFM. Eventually, it was found that the experimental measurements of R-curves and CZL showed a great agreement, in both of the fracture energy and the predicted load carrying capability. It thus demonstrated the validity of present research for the translaminar fracture of fiber-reinforced composite laminates.

  12. Surgery for scapula process fractures

    PubMed Central

    Anavian, Jack; Wijdicks, Coen A; Schroder, Lisa K; Vang, Sandy

    2009-01-01

    Background Generally, scapula process fractures (coracoid and acromion) have been treated nonoperatively with favorable outcome, with the exception of widely displaced fractures. Very little has been published, however, regarding the operative management of such fractures and the literature that is available involves very few patients. Our hypothesis was that operative treatment of displaced acromion and coracoid fractures is a safe and effective treatment that yields favorable surgical results. Methods We reviewed 26 consecutive patients (27 fractures) treated between 1998 and 2007. Operative indications for these process fractures included either a painful nonunion, a concomitant ipsilateral operative scapula fracture, ≥ 1 cm of displacement on X-ray, or a multiple disruption of the superior shoulder suspensory complex. All patients were followed until they were asymptomatic, displayed radiographic fracture union, and had recovered full motion with no pain. Patients and results 21 males and 5 females, mean age 36 (18–67) years, were included in the study. 18 patients had more than one indication for surgery. Of the 27 fractures, there were 13 acromion fractures and 14 coracoid fractures. 1 patient was treated for both a coracoid and an acromion fracture. Fracture patterns for the acromion included 6 acromion base fractures and 7 fractures distal to the base. Coracoid fracture patterns included 11 coracoid base fractures and 3 fractures distal to the base. Mean follow-up was 11 (2–42) months. All fractures united and all patients had recovered full motion with no pain at the time of final follow-up. 3 patients underwent removal of hardware due to irritation from hardware components that were too prominent. There were no other complications. Interpretation While most acromion and coracoid fractures can be treated nonoperatively with satisfactory results, operative management may be indicated for displaced fractures and double lesions of the superior shoulder suspensory complex. PMID:19857183

  13. Functional outcomes of conservatively treated clavicle fractures

    PubMed Central

    Bajuri, Mohd Yazid; Maidin, S; Rauf, A; Baharuddin, M; Harjeet, S

    2011-01-01

    OBJECTIVE: The main aim of the study was to analyze the outcomes of clavicle fractures in adults treated non-surgically and to evaluate the clinical effects of displacement, fracture patterns, fracture location, fracture comminution, shortening and fracture union on shoulder function. METHODS: Seventy clavicle fractures were non-surgically treated in the Orthopedics Department at the Tuanku Ja'afar General Hospital, a tertiary care hospital in Seremban, Malaysia, an average of six months after injury. The clavicle fractures were treated conservatively with an arm sling and a figure-eight splint for three weeks. No attempt was made to reduce displaced fractures, and the patients were allowed immediate free-shoulder mobilization, as tolerated. They were prospectively evaluated clinically and radiographically. Shoulder function was evaluated using the Constant scoring technique. RESULTS: There were statistically significant functional outcome impairments in non-surgically treated clavicle fractures that correlated with the fracture type (comminution), the fracture displacement (21 mm or more), shortening (15 mm or more) and the fracture union (malunion). CONCLUSION: This article reveals the need for surgical intervention to treat clavicle fractures and improve shoulder functional outcomes. PMID:21655759

  14. Transosseous fixation of pediatric displaced mandibular fractures with polyglactin resorbable suture--a simplified technique.

    PubMed

    Chandan, Sanjay; Halli, Rajshekhar; Joshi, Samir; Chhabaria, Gaurav; Setiya, Sneha

    2013-11-01

    Management of pediatric mandibular fractures presents a unique challenge to surgeons in terms of its numerous variations compared to adults. Both conservative and open methods have been advocated with their obvious limitations and complications. However, conservative modalities may not be possible in grossly displaced fractures, which necessitate the open method of fixation. We present a novel and simplified technique of transosseous fixation of displaced pediatric mandibular fractures with polyglactin resorbable suture, which provides adequate stability without any interference with tooth buds and which is easy to master.

  15. Reliability of Radiographic Assessments of Adolescent Midshaft Clavicle Fractures by the FACTS Multicenter Study Group.

    PubMed

    Li, Ying; Donohue, Kyna S; Robbins, Christopher B; Pennock, Andrew T; Ellis, Henry B; Nepple, Jeffrey J; Pandya, Nirav; Spence, David D; Willimon, Samuel Clifton; Heyworth, Benton E

    2017-09-01

    There is a recent trend toward increased surgical treatment of displaced midshaft clavicle fractures in adolescents. The primary purpose of this study was to evaluate the intrarater and interrater reliability of clavicle fracture classification systems and measurements of displacement, shortening, and angulation in adolescents. The secondary purpose was to compare 2 different measurement methods for fracture shortening. This study was performed by a multicenter study group conducting a prospective, comparative, observational cohort study of adolescent clavicle fractures. Eight raters evaluated 24 deidentified anteroposterior clavicle radiographs selected from patients 10-18 years of age with midshaft clavicle fractures. Two clavicle fracture classification systems were used, and 2 measurements for shortening, 1 measurement for superior-inferior displacement, and 2 measurements for fracture angulation were performed. A minimum of 2 weeks after the first round, the process was repeated. Intraclass correlation coefficients were calculated. Good to excellent intrarater and interrater agreement was achieved for the descriptive classification system of fracture displacement, direction of angulation, presence of comminution, and all continuous variables, including both measurements of shortening, superior-inferior displacement, and degrees of angulation. Moderate agreement was achieved for the Arbeitsgemeinschaft für Osteosynthesefragen classification system overall. Mean shortening by 2 different methods were significantly different from each other (P < 0.0001). Most radiographic measurements performed by investigators in a multicenter, prospective cohort study of adolescent clavicle fractures demonstrated good-to-excellent intrarater and interrater reliability. Future consensus on the most accurate and clinically appropriate measurement method for fracture shortening is critical.

  16. Contact characteristics of the subtalar joint after a simulated calcaneus fracture.

    PubMed

    Sangeorzan, B J; Ananthakrishnan, D; Tencer, A F

    1995-06-01

    A simple calcaneus fracture consisting of two parts was modeled in nine fresh cadaver hindfoot specimens to assess changes in subtalar joint contact characteristics with increasing plantar depression of the posterolateral fracture component. To perform the experiment, rods were placed in the tibial and fibular shafts of each specimen, which was mounted in a frame in neutral stance. A pneumatic cylinder was used to deliver a vertical compressive load through the rods into the foot while permitting free motion of the foot in the horizontal plane. Sealed packets of pressure-sensitive film were inserted into the anterior-middle and posterior facets of the talocalcaneal articulation, and a 700-N load was applied. After testing of the intact foot, a primary fracture line was created using a microoscillating saw. The osteotomized posterolateral component was anatomically reduced and fixed, the film inserted, and the load reapplied. The test was repeated after the posterolateral fragment was displaced 2, 5, and 10 mm in a plantar direction. The resulting pressure prints were scanned along with pressure/color density calibration strips using a flat-bed scanner, and an image analysis system was used to determine contact areas within specified pressure intervals. The contact area (> 0.5 MPa) of the posterior facet was significantly decreased with 2, 5, and 10 mm displacements of the posterolateral calcaneus fracture component. The ratio of high-pressure area (< 5.0 MPa) to contact area in the posterior facet was significantly increased only with displacements of 5 and 10 mm. There were no significant changes in any contact parameters in the anterior-middle facet.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Reliability of internal oblique elbow radiographs for measuring displacement of medial epicondyle humerus fractures: a cadaveric study.

    PubMed

    Gottschalk, Hilton P; Bastrom, Tracey P; Edmonds, Eric W

    2013-01-01

    Standard elbow radiographs (AP and lateral views) are not accurate enough to measure true displacement of medial epicondyle fractures of the humerus. The amount of perceived displacement has been used to determine treatment options. This study assesses the utility of internal oblique radiographs for measurement of true displacement in these fractures. A medial epicondyle fracture was created in a cadaveric specimen. Displacement of the fragment (mm) was set at 5, 10, and 15 in line with the vector of the flexor pronator mass. The fragment was sutured temporarily in place. Radiographs were obtained at 0 (AP), 15, 30, 45, 60, 75, and 90 degrees (lateral) of internal rotation, with the elbow in set positions of flexion. This was done with and without radio-opaque markers placed on the fragment and fracture bed. The 45 and 60 degrees internal oblique radiographs were then presented to 5 separate reviewers (of different levels of training) to evaluate intraobserver and interobserver agreement. Change in elbow position did not affect the perceived displacement (P=0.82) with excellent intraobserver reliability (intraclass correlation coefficient range, 0.979 to 0.988) and interobserver agreement of 0.953. The intraclass correlation coefficient for intraobserver reliability on 45 degrees internal oblique films for all groups ranged from 0.985 to 0.998, with interobserver agreement of 0.953. For predicting displacement, the observers were 60% accurate in predicting the true displacement on the 45 degrees internal oblique films and only 35% accurate using the 60 degrees internal oblique view. Standardizing to a 45 degrees internal oblique radiograph of the elbow (regardless of elbow flexion) can augment the treating surgeon's ability to determine true displacement. At this degree of rotation, the measured number can be multiplied by 1.4 to better estimate displacement. The addition of a 45 degrees internal oblique radiograph in medial humeral epicondyle fractures has good intraobserver and interobserver reliability to more accurately estimate the true displacement of these fractures. Diagnostic study, Level II (Development of diagnostic study with universally applied reference "gold" standard).

  18. Computed tomography of calcaneal fractures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heger, L.; Wulff, K.; Seddiqi, M.S.A.

    1985-07-01

    Computed tomography (CT) of 25 fractured calcanei was performed to investigate the potential of CT in evaluating the pattern and biomechanics of these fractures. The characteristic findings of typical fractures are presented, including the number and type of principal fragments, size and dislocation of the sustentacular fragment, and involvement of the anterior and posterior facets of the subtalar joint. In 17 cases, the calcaneus consisted of four or more fragments. Furthermore, in 17 cases the sustentacular fragment included all or part of the posterior facet joint. In 18 of the 25 cases, the sustentacular fragment was displaced. It is concludedmore » that well performed CT is an invaluable adjunct in understanding the fracture mechanism and in detecting pain-provoking impingement between the fibular malleolus and the tuberosity fragment.« less

  19. Relationships between fractures

    NASA Astrophysics Data System (ADS)

    Peacock, D. C. P.; Sanderson, D. J.; Rotevatn, A.

    2018-01-01

    Fracture systems comprise many fractures that may be grouped into sets based on their orientation, type and relative age. The fractures are often arranged in a network that involves fracture branches that interact with one another. Interacting fractures are termed geometrically coupled when they share an intersection line and/or kinematically coupled when the displacements, stresses and strains of one fracture influences those of the other. Fracture interactions are characterised in terms of the following. 1) Fracture type: for example, whether they have opening (e.g., joints, veins, dykes), closing (stylolites, compaction bands), shearing (e.g., faults, deformation bands) or mixed-mode displacements. 2) Geometry (e.g., relative orientations) and topology (the arrangement of the fractures, including their connectivity). 3) Chronology: the relative ages of the fractures. 4) Kinematics: the displacement distributions of the interacting fractures. It is also suggested that interaction can be characterised in terms of mechanics, e.g., the effects of the interaction on the stress field. It is insufficient to describe only the components of a fracture network, with fuller understanding coming from determining the interactions between the different components of the network.

  20. Outcomes of nonoperatively treated displaced scapular body fractures.

    PubMed

    Dimitroulias, Apostolos; Molinero, Kenneth G; Krenk, Daniel E; Muffly, Matthew T; Altman, Daniel T; Altman, Gregory T

    2011-05-01

    Displaced scapular body fractures most commonly are treated conservatively. However there is conflicting evidence in the literature regarding the outcomes owing to retrospective design of studies, different classification systems, and diverse outcome tools. The functional outcome after nonoperative management of displaced scapular body fractures was assessed by change in the DASH (Disability of Arm, Shoulder and Hand) score; (2) the radiographic outcome was assessed by the change of the glenopolar angle (GPA); and (3) associated scapular and extrascapular injuries that may affect outcome were identified. Forty-nine consecutive patients were treated with early passive and active ROM exercises for a displaced scapular body fracture. We followed 32 of these patients (65.3%) for a minimum of 6 months (mean, 15 months; range, 6-33 months). Mean age of the patients was 46.9 years (range, 21-84 years) and the mean Injury Severity Score (ISS) was 21.5 (range, 5-50). Subjective functional results (DASH score) and radiographic assessment (fracture union, glenopolar angle) were measured. All fractures healed uneventfully. The mean change of glenopolar angle was 9° (range, 0°-20°). The mean change of the DASH score was 10.2, which is a change with minimal clinical importance. There was a correlation between the change in this score with the ISS and presence of rib fractures. Satisfactory outcomes are reported with nonoperative treatment of displaced scapular body fractures. We have shown that the severity of ISS and the presence of rib fractures adversely affect the clinical outcome.

  1. Treatment dilemma in multiple metatarsal fractures: when to operate?

    PubMed

    Mahan, Susan T; Lierhaus, Anneliese M; Spencer, Samantha A; Kasser, James R

    2016-07-01

    Fractures of multiple metatarsals in the pediatric population are uncommon; however, indications for surgical treatment have not been delineated. The aim of this study was to review multiple metatarsal fractures to help refine surgical indications. A total of 98 patients had multiple metatarsal fractures; displacement greater than 10% shaft width (displaced) was encountered in 33 (34.0%) patients. Fifteen patients had displacement of more than 75% shaft width of one metatarsal. Patients older than 14 years of age were more likely to have surgery for their injury (52.6%) than those younger than 14 years of age (3.7%) (P<0.0001). Younger patients and those with less than 75% displacement should be considered for nonoperative care. Level IV.

  2. An orthopedic surgeon survey on the treatment of displaced femoral neck fracture: opposing views

    PubMed Central

    Chua, David; Jaglal, Susan B.; Schatzker, Joseph

    1997-01-01

    Objective To examine the reasons for practice variation in the treatment of displaced femoral neck fractures. Design A survey, asking surgeons to choose either hemiarthroplasty or internal fixation for 2 different female patients with a displaced femoral neck fracture. Setting The Canadian Orthopaedic Association Meeting, Halifax, May 1995. Patients The scenario in the first patient was of an independent 70-year-old woman with no pre-existing medical conditions. The scenario in the second patient was of a housebound 84-year-old woman with co-morbidity. Main outcome measures Proportion of surgeons choosing either hemiarthroplasty or internal fixation for each case scenario. Distribution of reasons to explain the treatment decision. Results Ninety-nine surgeons responded. For the case of the 70-year-old woman, 47% chose hemiarthroplasty and 53% chose internal fixation (p = 0.60), and for the 84-year-old woman, 96% chose hemiarthroplasty. These findings were consistent within the subgroups of teaching surgeons and community practice surgeons. Surgeons with 10 years or less of practice tended to favour hemiarthroplasty whereas those with more than 15 years’ practice favoured internal fixation. Important reasons for treatment choice were avoidance of reoperation in the hemiarthroplasty group (85%) and better hip function in the fixation group (83%), durability (83%) and ease of revision (77%). Conclusion The surgeon’s interpretation of the importance of reoperation and function underlies the differences in treatment decision regarding the management of femoral neck fractures in elderly patients. PMID:9267295

  3. Outcome of low profile mesh plate in management of comminuted displaced fracture patella.

    PubMed

    Singer, Mohamed S; Halawa, Abdelsamie M; Adawy, Adel

    2017-06-01

    To assess the clinical results of using mesh plate in management of displaced comminuted fracture patella. Between January 2014 and October 2015, nine patients with closed displaced comminuted fracture patella were fixed using mesh plate and 2mm mini screws. All fractures united after an average of 10 weeks. At final follow-up of an average 19.6 months, average postoperative Lysholm score was 89.1±4.9, and average Postoperative Böstman scale was 27.2±3.1. No hardware related complications were recorded. Low profile mesh plate is a good option in management of comminuted fracture patella with good clinical outcome. This new surgical technique may be particularly useful in comminuted fractures when patellectomy would otherwise be considered. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Functional outcomes of Gartland III supracondylar humerus fractures with early neurovascular complications in children: A retrospective observational study.

    PubMed

    Wang, Sung Il; Kwon, Tae Young; Hwang, Hong Pil; Kim, Jung Ryul

    2017-06-01

    This was a retrospective observational study. The aim of this study was to evaluate functional outcomes in children treated for Gartland III supracondylar humerus (SCH) fracture with neurovascular (NV) injuries using validated outcome measures. A secondary goal was to determine whether clinical parameters such as age at injury, sex, weight, fracture site, and/or direction of displacement could predict NV injury at the time of fracture or long-term functional outcomes in these patients.One hundred fifty-four patients of Gartland III SCH fractures between March 2004 and May 2013 were studied retrospectively. The patients were divided into 2 groups according to the presence of NV injury. Medical records and radiographs were reviewed to assess several parameters, including age, sex, weight, treatment intervention, the extremity involved, direction of fracture displacement, and NV injury. Functional outcome was assessed on final follow-up using the Pediatric Outcomes Data Collection Instrument (PODCI) and Quick Disabilities of the Arm, Shoulder, and Hand (Quick DASH) outcome measures. Statistical analysis was used to determine the relationship between NV injury and functional outcomes.There were 33 cases with Gartland III SCH fracture associated with NV injuries (10 cases of vascular compromise, 14 cases of neural injury, and 9 cases involving both vascular compromise and neural injury). There were significant differences between the 2 groups in age (P  =  .048), weight (P  =  .009), and direction of displacement (P  =  .004). Vascular compromise and median nerve injury were most common in fractures with posterolateral displacement, and radial nerve injuries were common in fractures with posteromedial displacement. The mean global function score in the PODCI was 91.4 points, and the mean Quick DASH score was 11.7 points, with excellent functional outcomes. No differences in outcomes were identified based upon age, fracture site, sex, weight, direction of displacement, or operative technique in NV injury patients (P > .05).The majority of patients with Gartland III SCH fractures associated with NV injuries returned to a high functioning level after treatment of their injuries. NV injury does not appear to influence functional outcomes. Good functional results can be expected regardless of age, fracture site, sex, weight, direction of displacement, and operative technique.

  5. In-Situ Ultra Low Frequency Poroelastic Response of a Natural Macro-Fracture

    NASA Astrophysics Data System (ADS)

    Guglielmi, Y.; Cappa, F.; Rutqvist, J.; Tsang, C.; Gaffet, S.

    2008-12-01

    The seismic visibility of macro-fractures filled with fluids is a central problem in the exploration of thermo- hydro-mechanical and chemical processes that occur in Earth' s subsurface. Most studies have been concerned (1) with cracks of a small size relative to the seismic wavelength (2) with "core-sized" samples of single macro-fractures. In comparison, in-situ studies of macro-fractures are very rare and no real estimate is made of the relevance of this convenient "core-sized" data to in-situ reservoirs in general. In this study, we present a new experimental approach to in-situ characterize mechanical and hydraulic properties of fractures using the innovative HPPP protocol. This protocol allows simultaneous high-frequency (120.2 Hz) sampling of normal displacement and fluid pressure in a borehole intersecting the fracture. We show preliminary results conducted in a single fracture vertically embedded in a carbonate reservoir that contains 3 sets of macro-fractures with an average 2m spacing. Two HPPP probes were set, spaced one meter vertically in the fracture. Two types of ULF seismic sources are applied: a fluid pressure pulse injected in the fracture and a hammer hit at a point located 5m far from the fracture plane. There is a highly non-linear variation of fracture normal displacement-versus- fluid pressure as a function of frequency, the higher the frequency, the lower the displacement spectral amplitude is. The pressure pulse and the hammer hit allow exploring the fracture poroelastic response in the [0 - 3Hz] frequency range. The fracture plays the role of a "low-pass" filter for fluid pressure waves; only a quasi-static pressure signal being registered at the receiver. The displacement wave propagation is more complex resulting in uncoupled quasi-static-pressure-2Hz-deformation signals at the receiver. For low magnitude seismic sources (low amplitude pulse and seismic wave), the fracture natural resonance is amplified resulting in separate signals power spectral peaks. When fluid pressure is enough increased, hydraulic diffusion takes place at frequencies lower than 1.2 Hz. Poroelastic effects related to static hydraulic diffusion and to wave propagation were described separately using a linear elastic model where the fracture was treated as a displacement discontinuity across which stresses are continuous but displacement are discontinuous. It appears that the dynamic fracture normal stiffness at 2 to 3 Hz is a factor of 2.8 higher than the static stiffness although the fracture displays a high hydraulic aperture of 10-4 m. This surprising result is related to a high heterogeneity of the fracture channel network with a large porosity/permeability contrast that does not allow fluid displacement under dynamic loading. The HPPP approach appears as a possibility to in-situ characterize such fractures static to seismic poroelastic heterogeneous properties.

  6. Surface Deformation and Direct Field Observation to Constrain Conceptual Models of Hydraulic Fracture Growth and Form

    NASA Astrophysics Data System (ADS)

    Slack, W.; Murdoch, L.

    2016-12-01

    Hydraulic fractures can be created in shallow soil or bedrock to promote processes that destroy or remove chemical contaminants. The form of the fracture plays an important role in how it is used in such applications. We created more than 4500 environmental hydraulic fractures at approximately 300 sites since 1990, and we measured surface deformation at many. Several of these sites subsequently were excavated to evaluate fracture form in detail. In one recent example, six hydraulic fractures were created at 1.5m depth while we measured upward displacement and tilt at 15 overlying locations. We excavated in the vicinities of two of the fractures and mapped the exposed fractures. Tilt vectors were initially symmetric about the borehole but radiated from a point that moved southwest with time. Upward displacement of as much as 2.5 cm covered a region 5m to 6m across. The maximum displacement was roughly at the center of the deformed region but was 2m southwest of the borehole, consistent with the tilt data. Excavation revealed an oblong, proppant-filled fracture over 4.2 m in length with a maximum thickness of 1 cm, so the proppant covers a region that is smaller than the uplifted area and the proppant thickness is roughly half of the uplift. The fracture was shaped like a shallow saucer with maximum dips of approximately 15o at the southwestern end. The pattern of tilt and uplift generally reflect the aperture of the underlying pressurized fracture, but the deformation extends beyond the extent of the sand proppant so a quantitative interpretation requires inversion. Inversion of the tilt data using a simple double dislocation model under-estimates the extent but correctly predicts the depth, orientation, and off-centered location. Inversion of uplift using a model that assumes the overburden deforms like a plate over-estimates the extent. Neither can characterize the curved shape. A forward model using FEM analysis capable of representing 3D shapes is capable of more accurate interpretations of fracture form and extent, but it comes at a cost of more parameters and a greater computational burden compared to the analytical forward models. The best approach is the combination of all three forward models to interpret the deformation data.

  7. [BIOMECHANICAL COMPARATIVE STUDY ON FOUR INTERNAL FIXATIONS FOR ACETABULAR FRACTURES IN QUADRILATERAL AREA].

    PubMed

    Wang, Lei; Wu, Xiaobo; Qi, Wei; Wang, Yongbin; He, Quanjie; Xu, Fengsong; Liu, Hongyang

    2015-10-01

    To compare the biomechanical difference of 4 kinds of internal fixations for acetabular fracture in quadrilateral area. The transverse fracture models were created in 16 hemipelves specimens from 8 adult males, and were randomly divided into 4 groups according to different internal fixation methods (n = 4): infrapectineal buttress reconstruction plate (group A), infrapectineal buttress locking reconstruction plate (group B), reconstruction plate combined with trans-plate quadrilateral screws (group C), and anterior reconstruction plate-lag screw (group D). Then the horizontal displacement, longitudinal displacement of fractures, and axial stiffness were measured and counted to compare the stability after continuous vertical loading. Under the same loading, the horizontal and longitudinal displacements of groups A, B, C, and D were decreased gradually; when the loading reached 1 800 N, the longitudinal displacement of group A was more than 3.00 mm, indicating the failure criterion, while the axial stiffness increased gradually. Under 200 N loading, there was no significant difference (P > 0.05) in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups. When the loading reached 600-1 800 N, significant differences were found in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups (P < 0.05) except the horizontal displacement between groups C and D (P > 0.05). For acetabular fracture in the quadrilateral area, anterior reconstruction plate-lag screw for internal fixation has highest stability, followed by reconstruction plate combined with trans-plate quadrilateral screws, and they are better than infrapectineal buttress reconstruction plate and infrapectineal buttress locking reconstruction plate.

  8. Cement augmentation of implants--no general cure in osteoporotic fracture treatment. A biomechanical study on non-displaced femoral neck fractures.

    PubMed

    Hofmann-Fliri, Ladina; Nicolino, Tomas I; Barla, Jorge; Gueorguiev, Boyko; Richards, R Geoff; Blauth, Michael; Windolf, Markus

    2016-02-01

    Femoral neck fractures in the elderly are a common problem in orthopedics. Augmentation of screw fixation with bone cement can provide better stability of implants and lower the risk of secondary displacement. This study aimed to investigate whether cement augmentation of three cannulated screws in non-displaced femoral neck fractures could increase implant fixation. A femoral neck fracture was simulated in six paired human cadaveric femora and stabilized with three 7.3 mm cannulated screws. Pairs were divided into two groups: conventional instrumentation versus additional cement augmentation of screw tips with 2 ml TraumacemV+ each. Biomechanical testing was performed by applying cyclic axial load until failure. Failure cycles, axial head displacement, screw angle changes, telescoping and screw cut-out were evaluated. Failure (15 mm actuator displacement) occurred in the augmented group at 12,500 cycles (± 2,480) compared to 15,625 cycles (± 4,215) in the non-augmented group (p = 0.041). When comparing 3 mm vertical displacement of the head no significant difference (p = 0.72) was detected between the survival curves of the two groups. At 8,500 load-cycles (early onset failure) the augmented group demonstrated a change in screw angle of 2.85° (± 0.84) compared to 1.15° (± 0.93) in the non-augmented group (p = 0.013). The results showed no biomechanical advantage with respect to secondary displacement following augmentation of three cannulated screws in a non-displaced femoral neck fracture. Consequently, the indication for cement augmentation to enhance implant anchorage in osteoporotic bone has to be considered carefully taking into account fracture type, implant selection and biomechanical surrounding. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Analysis of hydromechanical well tests in fractured sedimentary rock at the NAWC site, New Jersey

    USGS Publications Warehouse

    Murdoch, L.C.; Hisz, D.B.; Ebenhack, J.F.; Fowler, D.E.; Tiedeman, C.R.; Germanovich, L.N.

    2009-01-01

    Hydromechanical well tests involve measuring and interpreting displacements along with hydraulic heads that result when a hydraulic stress is applied to a well. The motivation behind this type of test is that the displacement measurements provide information about the constitutive properties and structure of the aquifer that go beyond what can be derived from pressure signals alone. We used a borehole extensometer to measure transient displacements with a resolution of +/- 25 nm during well tests in fractured mudstone and sandstone at the former Naval Air Warfare Center in West Trenton, New Jersey. One well showed opening displacements on the order of 300nm during slug tests with maximum head changes of 7 m. Inversion of the transient signals suggest that a conductive fracture (aperture = 380 ??m, normal stiffness = 8??10 8 Pa/m) was largely responsible for the pressure signal, but the displacement signal appears to have resulted from both the fracture and deformation of the enveloping sandstone (E = 5 GPa, permeability = 0.6 md). At another well, an anomalous but repeatable signal was characterized by closing displacements during increasing pressure. This displacement signal can be explained by a hydraulically active fracture below the extensometer that became pressurized and compressed the overly sediments. Poroelastic theoretical analyses were inverted to estimate parameters and verify interpretations. Copyright 2009 ARMA, American Rock Mechanics Association.

  10. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    PubMed

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  11. Posterolaterally Displaced and Flexion Type Supracondylar Fractures are Associated with a Higher Risk of Open Reduction

    PubMed Central

    Novais, Eduardo N.; Carry, Patrick M.; Mark, Bryan J.; Sayan, DE; Miller, Nancy H.

    2016-01-01

    Objective To identify factors predictive of the risk of conversion from closed to open reduction. Methods ICD-9 codes were used to identify completely displaced pediatric supracondylar humerus fractures that underwent planned closed reduction and percutaneous pinning. Clinical and radiographic variables were retrospectively collected. Results Compared to posterior extension fractures, flexion [Risk Ratio (RR): 34.1, 95% CI: 8.1 to 143.6, p<0.0001] and posterolateral extension [RR: 6.0, 95% CI: 1.3 to 27.5, p=0.0221] fractures were significantly more likely to undergo conversion from closed to open reduction. Conclusions The direction of displacement should be considered during the pre-operative evaluation of supracondylar fractures. PMID:27035497

  12. Initial varus displacement of proximal humerus fractures results in similar function but higher complication rates.

    PubMed

    Capriccioso, Christina E; Zuckerman, Joseph D; Egol, Kenneth A

    2016-04-01

    To investigate the effect of initial varus or valgus surgical neck alignment on outcomes of patients who sustained proximal humerus fractures treated with open reduction and internal fixation (ORIF). An institutional review board approved database of proximal humerus fractures treated with locked plates was reviewed. Of 185 fractures in the database, 101 fractures were identified and met inclusion criteria. Initial varus displacement was seen in 47 fractures (OTA types 11.A2.2, A3.1, A3.3, B1.2, B2.2, C1.2, C2.2, or C2.3) and initial valgus displacement was observed in 54 fractures (OTA types 11.A2.3, B1.1, C1.1, or C2.1). All patients were treated in a similar manner and examined by the treating physician at standard intervals. Functional outcomes were quantified via the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and physical examination data at 12 months. Radiographs were reviewed for complications of healing. Additionally, complication rate and reoperation rate were investigated. Patients who presented with initial varus displacement had an average age of 59.3 years, while patients in the valgus group had an average age of 62.4 years. Overall, there was no statistically significant difference in age, sex distribution, BMI, fracture parts, screws used, or implant plate type between the two groups. At a minimum 12 months follow up, there was no significant difference in DASH scores between those presenting with varus versus valgus fracture patterns. In addition, no significant differences were seen in final shoulder range of motion in any plane. Overall, 30 patients included in this study developed a complication. A significantly greater number of patients in the initial varus cohort developed complications (40.4%), as compared to 20.3% of patients in the initial valgus cohort (P=0.03). Fourteen patients in this study underwent reoperation. Nine of these patients were in the varus cohort, while 5 were in the valgus cohort (P=0.15). In this study, initial surgical neck displacement in varus or valgus was found to not significantly affect functional outcome. Based upon our findings, patients with varus displaced proximal humerus fractures are at a greater risk of developing postoperative complications than those who present with initial valgus displaced fracture patterns. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation.

    PubMed

    Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas

    2008-02-01

    Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.

  14. Surgical treatment on displaced and dislocated sagittal fractures of the mandibular condyle.

    PubMed

    Jing, Jie; Han, Yu; Song, Yu; Wan, Yingbiao

    2011-06-01

    The purpose of this study was to evaluate the effect of surgical treatment on displaced and dislocated sagittal fractures of the mandibular condyle (SFMC). Twenty-four patients with 28 displaced and dislocated SFMCs were distinguished into type M, type C, and type L fractures according the location of the fracture line. The fractured fragment was reduced and fixated with two 0.6-mm 4-hole micro-plates via a preauricular temporal incision. The fragment was extirpated when it was too small to be fixated. The postoperative position and profile of the fragment was examined by orthopantomogram radiograph or computed tomography (CT). The function of the temporal and zygomatic branches of the facial nerve was inspected. The occluding relation was surveyed, the interincisal distance at maximum mouth opening was measured, and the deviation from the midline during mouth opening was recorded. Twenty-three condyles (82%) suffered dislocated fractures with the condylar fragment out of the glenoid fossa. Five condyles (18%) were displaced, but not dislocated. There were 2 (7%) type M, 19 (68%) type C (3 comminuted), and 7 (25%) type L fractures (1 comminuted), respectively. Twenty-one (75%) fractured fragments received free-graft procedures with 2 micro-plates. Four (14%) fragments were reduced and fixated without being dissected free of their attachments. Three (11%) fragments were extirpated. There were no permanent facial never branch injuries. Micro-plate removal was necessary because of postoperative infection and necrosis of the fractured fragment in 1 condylar process. No other patients could be found with obvious postoperative bone resorption. The average postoperative maximum mouth opening and deviation at 6 months were improved significantly. The postoperative occlusion was good in 22 cases. Access with the preauricular incision, and the dislocated and displaced fragment can be reduced and fixated to its normal position easily. Free-graft procedure is a suitable surgical treatment if the fractured fragment cannot be reduced without dissection free of the pterygoid muscle attachment. Although most fractured fragments in SFMCs have to be dissected free, there are no obvious complications in dislocated and displaced SFMCs after surgical treatment. Copyright © 2011 Mosby, Inc. All rights reserved.

  15. A prospective study on the effectiveness of cotton versus waterproof cast padding in maintaining the reduction of pediatric distal forearm fractures.

    PubMed

    Robert, Christopher E; Jiang, Jimmy J; Khoury, Joseph G

    2011-03-01

    Distal forearm fractures, one of the most common fractures seen in the pediatric population, are regularly treated by closed reduction and casting. Our study investigates the effectiveness of Gore-Tex-lined casting in maintaining the reduction of 100% displaced distal forearm fractures compared with traditional cotton-lined casts. We screened all patients from February 2007 to July 2009 who presented to Children's Hospital in Birmingham, AL with a distal radius fracture. Only patients with 100% displaced distal radius fractures were eligible to be assigned to either the cotton-lined or Gore-Tex-lined cast groups. Power analysis was performed to identify an adequate patient sample size. The mean maximum change between initial post-reduction x-rays and follow-up x-rays for anterior-posterior (AP) angulation, AP displacement, lateral angulation, and lateral displacement of the radius were calculated for both cotton and Gore-Tex groups. The rate of subsequent intervention and/or unacceptable results for each group was also analyzed. Seven hundred and twenty-two patients were treated with distal radius fractures at our hospital with 59 patients eligible for inclusion in our study. Thirty-six of our patients were treated with cotton-lined casts, and 23 patients were treated with Gore-Tex-lined cast. The mean maximum change in AP angulation, AP displacement, lateral angulation, and lateral displacement of the radius after initial reduction was 9.2 degrees, 6.9%, 13.9 degrees, and 13.6%, respectively, for the cotton-lined cast group and 7.7 degrees, 6.1%, 14.6 degrees, and 9.6%, respectively, for the Gore-Tex-lined cast group. There were no statistical differences between the means of the 4 measurements (P=0.33, 0.69, 0.73, and 0.10, respectively). There were also no significant differences between groups for final AP and lateral angulation and displacement. Subgroup analysis showed no significant differences in all measurements between cotton and Gore-Tex groups. Gore-Tex and cotton-lined casts are equally effective in their ability to maintain the reduction of 100% displaced distal forearm fractures. Thus, Gore-Tex-lined casts can be offered to pediatric patients immediately after closed reduction of distal radius fractures of any severity. Therapeutic level II.

  16. The Comprehensive AOCMF Classification System: Condylar Process Fractures - Level 3 Tutorial

    PubMed Central

    Neff, Andreas; Cornelius, Carl-Peter; Rasse, Michael; Torre, Daniel Dalla; Audigé, Laurent

    2014-01-01

    This tutorial outlines the detailed system for fractures of the condylar process at the precision level 3 and is organized in a sequence of sections dealing with the description of the classification system within topographical subdivisions along with rules for fracture coding and a series of case examples with clinical imaging. Basically, the condylar process comprises three fracture levels and is subdivided into the head region, the condylar neck, and the condylar base. Fractures of the condylar head show typical fracture lines either within the lateral pole zone, which may lead to loss of vertical height, or medially to the pole zone, with the latter ones usually not compromising the vertical condyle to fossa relation. In condylar head fractures, the morphology is further described by the presence of minor or major fragmentation, the vertical apposition of fragments at the plane of the head fracture, the displacement of the condylar head with regard to the fossa including a potential distortion of the condylar head congruency resulting in dystopic condyle to fossa relations and the presence or absence of a loss of vertical ramus height. A specific vertical fracture pattern extending from the head to the neck or base subregion is considered. Fractures of the condylar neck and base can be differentiated according to a newly introduced one-third to two-thirds rule with regard to the proportion of the fracture line above and below the level of the sigmoid notch, which is presented in the classification article, and are basically subdivided according to the presence or absence of displacement or dislocation. In both condylar neck and base fractures, the classification is again based on the above mentioned parameters such as fragmentation, displacement of the condylar head with regard to the fossa, including dystopic condyle to fossa relations and loss of vertical ramus height, that is, according to the measurement of the condylar process. In addition, the classification assesses a sideward displacement including the respective displacement sector at the neck or base fracture site as well as the angulation of the superior main fragment and also considers a potential displacement of the caudal fragment with regard to the fossa, which may occur in fractures affecting additional fracture locations in the mandible. The design of this classification is discussed along with a review of existing classification systems. The condylar process for fracture location was defined according to the level 2 system presented in a previous tutorial in this special issue. PMID:25489390

  17. The Comprehensive AOCMF Classification System: Condylar Process Fractures - Level 3 Tutorial.

    PubMed

    Neff, Andreas; Cornelius, Carl-Peter; Rasse, Michael; Torre, Daniel Dalla; Audigé, Laurent

    2014-12-01

    This tutorial outlines the detailed system for fractures of the condylar process at the precision level 3 and is organized in a sequence of sections dealing with the description of the classification system within topographical subdivisions along with rules for fracture coding and a series of case examples with clinical imaging. Basically, the condylar process comprises three fracture levels and is subdivided into the head region, the condylar neck, and the condylar base. Fractures of the condylar head show typical fracture lines either within the lateral pole zone, which may lead to loss of vertical height, or medially to the pole zone, with the latter ones usually not compromising the vertical condyle to fossa relation. In condylar head fractures, the morphology is further described by the presence of minor or major fragmentation, the vertical apposition of fragments at the plane of the head fracture, the displacement of the condylar head with regard to the fossa including a potential distortion of the condylar head congruency resulting in dystopic condyle to fossa relations and the presence or absence of a loss of vertical ramus height. A specific vertical fracture pattern extending from the head to the neck or base subregion is considered. Fractures of the condylar neck and base can be differentiated according to a newly introduced one-third to two-thirds rule with regard to the proportion of the fracture line above and below the level of the sigmoid notch, which is presented in the classification article, and are basically subdivided according to the presence or absence of displacement or dislocation. In both condylar neck and base fractures, the classification is again based on the above mentioned parameters such as fragmentation, displacement of the condylar head with regard to the fossa, including dystopic condyle to fossa relations and loss of vertical ramus height, that is, according to the measurement of the condylar process. In addition, the classification assesses a sideward displacement including the respective displacement sector at the neck or base fracture site as well as the angulation of the superior main fragment and also considers a potential displacement of the caudal fragment with regard to the fossa, which may occur in fractures affecting additional fracture locations in the mandible. The design of this classification is discussed along with a review of existing classification systems. The condylar process for fracture location was defined according to the level 2 system presented in a previous tutorial in this special issue.

  18. Treatment of displaced mandibular condylar fracture with botulinum toxin A.

    PubMed

    Akbay, Ercan; Cevik, Cengiz; Damlar, Ibrahim; Altan, Ahmet

    2014-04-01

    The aim of this case report is to discuss the effect on condylar reduction of botulinum toxin A treatment used in a child with displaced fracture at condylar neck of mandible. A 3-years old boy was admitted to our clinic for incomplete fracture of mandibular symphysis and displaced condylar fracture at the left side. An asymmetrical occlusal splint with intermaxillary fixation was used instead of open reduction and internal fixation because of incomplete fracture of symphysis and possible complications of condyle surgery. However, it was observed that condylar angulation persisted despite this procedure. Thus, botulinum toxin A was administered to masseter, temporalis and pterygoideus medialis muscles. At the end of first month, it was seen that mandibular condyle was almost completely recovered and that fusion was achieved. In conclusion, Botulinum A toxin injection aiming the suppression of masticatory muscle strength facilitates the reduction in the conservative management of displaced condyle in pediatric patients. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Patient satisfaction after open reduction and internal fixation through lateral extensile approach in displaced intraarticular calcaneal fractures (Sander's type II and III).

    PubMed

    Kavin, Khatri; Vijay, Sharma; Devendra, Lakhotia; Kamran, Farooque

    2016-01-01

    To determine patient satisfaction in the patients of displaced intraarticular calcaneal fractures treated with standard lateral approach. The patients of displaced calcaneal fractures (Sander's type II and III) treated between March 2009 and March 2012 were included in the retrospective review and functional outcome was evaluated using American Orthopaedic Foot and Ankle Society (AOFAS) hind foot score, Creighton Nebraska Health Foundation Assessment (CNHFA) scale and foot function index (FFI). The cohort included 26 patients (19 males: seven were females) with a mean age of 38.16 ± 13.53 years (range 18-64 years). The mean period of follow-up was 24.42 ± 6.68 months. The patients achieved good functional scores after anatomical reduction of the fracture. The complication rate was low following strict inclusion criteria. Careful patient selection in displaced intraarticular calcaneal fractures treated through lateral extensile approach achieves good patient satisfaction.

  20. Sports participation and radiographic findings of adolescents treated nonoperatively for displaced clavicle fractures.

    PubMed

    Robinson, Luke; Gargoum, Riyad; Auer, Ron; Nyland, John; Chan, Gilbert

    2015-07-01

    There is a relative paucity of high-level evidence that guides the treatment of displaced midshaft clavicle fractures in adolescents. Some use overhead sports or significant shortening as relative indications for surgical treatment, while others rarely consider operative intervention for these patients. The purpose of this study is to determine the effect of overhead sports participation and fracture shortening on subjective and objective outcomes after nonoperative treatment of displaced midshaft clavicle fractures in those aged 10-17 years. Using a radiographic database, adolescents with displaced clavicle fractures were identified and contacted over the phone. These subjects were invited to take part in the study in return for compensation. Radiographic measurements of dedicated clavicle films around the time of injury were performed, and a custom survey aimed at elucidating participation in overhead or contact sports was given. The Nottingham Clavicle Score (NCS) and the Constant Shoulder Score were obtained for each patient to provide both subjective and objective outcome data. Statistical Package for Social Science (SPSS) software (version 22, IBM) was used to compare radiographic and sports data to the outcome measures. Gender, age at the time of fracture, time since fracture, relative and absolute radiographic shortening, and hand dominance were all not significantly correlated with subjective or objective outcomes. Five patients (23%) reported not feeling happy with the appearance of their shoulder at the beach or at the pool. This group had statistically lower NCS results. Eleven of 22 participated in ≥6 months per year of overhead or contact sports; they did not have worse subjective or objective outcomes. Fracture shortening and sports participation do not have a significant impact in adolescents on outcomes after displaced midshaft clavicle fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Inverted distal clavicle anatomic locking plate for displaced medial clavicle fracture.

    PubMed

    Wang, Yong; Jiang, Jiannong; Dou, Bin; Zhang, Panjun

    2015-09-01

    Fractures of the medial clavicle are rare injuries. Recently, open reduction and internal fixation has been recommended for displaced medial clavicle fractures in order to prevent non-union and dysfunction. Because of the rarity of this injury, the optimal fixation device has not yet been established. In this report, we describe a case of a 40-year-old male patient who sustained a significantly displaced medial clavicle fracture treated by open reduction and internal fixation using an inverted distal clavicle anatomic locking plate. At the 12 months follow-up, the patient recovered well, had returned to pre-injury job, and was quite satisfied with the outcome. Internal fixation of medial clavicle fracture using an inverted distal clavicle anatomic locking plate of the ipsilateral side appears to be a good treatment option.

  2. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report

    PubMed Central

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Introduction: Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. Case Report: A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. Conclusion: A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients. PMID:29181350

  3. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report.

    PubMed

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients.

  4. Single-Session Combined Anterior-Posterior Approach for Treatment of Ankylosing Spondylitis with Obvious Displaced Lower Cervical Spine Fractures and Dislocations

    PubMed Central

    Yang, Baohui; Lu, Teng

    2017-01-01

    For patients with AS and lower cervical spine fractures, surgical methods have mainly included the single anterior approach, single posterior approach, and combined anterior-posterior approach. However, various surgical procedures were utilized because the fractures have not been clearly classified according to presence of displacement in these previous studies. Consequently, controversies have been raised regarding the selection of the surgical procedure. This study retrospective analysis was conducted in 12 patients with AS and lower cervical spine fractures and dislocations and explored single-session combined anterior-posterior approach for the treatment of AS with obvious displaced lower cervical spine fractures and dislocations which has demonstrated advantages such as good stabilization, satisfied fracture healing, and easy postoperative cares. However, to some extent, the difficulty and risk of this approach should be considered. Attention should be paid to the prevention of perioperative complications. PMID:28133616

  5. Inferior angle of scapula fractures: a review of literature and evidence-based treatment guidelines.

    PubMed

    Chang, Angela C; Phadnis, Joideep; Eardley-Harris, Nathan; Ranawat, Vijai S; Bain, Gregory I

    2016-07-01

    Inferior angle of scapula (IAS) fractures are rare, with very few cases reported. They typically present with pain, loss of shoulder motion, and scapula winging. Operative and nonoperative treatments have been trialed with varying success. The aim of this study was to gather data relating to IAS fractures to develop evidence-based treatment guidelines as none are currently available. A search was conducted of the PubMed and Google Scholar databases to identify cases of IAS fractures. Data collected about each case included age and gender of the patient, mechanism of injury, fracture displacement, treatment, and outcome. The authors report 2 additional IAS fracture cases. Ten cases were identified for inclusion in this study, 8 from the literature and 2 described by the authors. Of the 10 cases, 7 described displaced IAS fractures and 3 described undisplaced fractures. All displaced fractures treated nonoperatively resulted in a painful nonunion. All that underwent operative fixation, whether acutely or after failed nonoperative treatment, had resolution of pain and a good functional outcome. All undisplaced fractures were treated nonoperatively; 1 had persisting pain. Surgical exploration identified the fracture fragment attached to serratus anterior in 2 cases and attached to both serratus anterior and latissimus dorsi in 2 cases. There are limited data available about IAS factures. From the cases reviewed, treatment recommendations include the following: (1) displaced IAS fractures should undergo operative fixation to prevent the development of a painful nonunion; (2) suture repair provides adequate fixation; and (3) undisplaced fractures have a variable outcome when treated nonoperatively. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Surgical Strategy and Techniques for Low-Profile Dorsal Plating in Treating Dorsally Displaced Unstable Distal Radius Fractures

    PubMed Central

    Hamada, Yoshitaka; Gotani, Hiroyuki; Hibino, Naohito; Tanaka, Yoshitaka; Satoh, Ryousuke; Sasaki, Kousuke; Kanchanathepsak, Thepparat

    2016-01-01

    Background The low-profile dorsal locking plating (DLP) technique is useful for treating dorsally comminuted intra-articular distal radius fractures; however, due to the complications associated with DLP, the technique is not widely used. Methods A retrospective review of 24 consecutive cases treated with DLP were done. Results All cases were classified into two types by surgical strategy according to the fracture pattern. In type 1, there is a volar fracture line distal to the watershed line in the dorsally displaced fragment, and this type is treated by H-framed DLP. In type 2, the displaced dorsal die-punch fragment is associated with a minimally displaced styloid shearing fracture or a transverse volar fracture line. We found that the die-punch fragment was reduced by the buttress effect of small l-shaped DLP after stabilization of the styloid shearing for the volar segment by cannulated screws from radial styloid processes. At 6 months after surgery, outcomes were good or excellent based on the modified Mayo wrist scores with no serious complications except one case. The mean range of motion of each type was as follows: the palmar flexion was 50, 65 degrees, dorsiflexion was 70, 75 degrees, supination was 85, 85 degrees, and pronation was 80, 80 degrees; in type 1 and 2, respectively. Conclusion DLP is a useful technique for the treatment of selected cases of dorsally displaced, comminuted intra-articular fractures of the distal radius with careful soft tissue coverage. PMID:28428920

  7. Treatment of displaced intra-articular calcaneal fractures with triangular tube-to-bar external fixation: long-term clinical follow-up and radiographic analysis.

    PubMed

    Roukis, Thomas S; Wünschel, Markus; Lutz, Hans-Peter; Kirschner, Peter; Zgonis, Thomas

    2008-04-01

    Sixty-six feet (62 patients) with displaced intra-articular calcaneal fractures underwent manual reduction and distraction with the use of a triangular tube-to-bar external fixation device and were retrospectively reviewed at a minimum of 1-year post-operative. Final radiographic follow-up revealed complete consolidation in all fractures, maintenance of reduction, and limited degenerative osteoarthrosis about the subtalar joint. Our results indicate that with proper application and attention to detail, restoration of calcaneal morphology using triangular tube-to-bar external fixation should be considered a viable alternative in the treatment of displaced intra-articular fractures of the calcaneus.

  8. Reconstruction of the pelvic brim and its role in the reduction accuracy of displaced T-shaped acetabular fracture.

    PubMed

    Harnroongroj, T; Asavamongkolkul, A; Chareancholvanich, K

    2000-05-01

    Open reduction of the displaced T-shaped acetabular fracture has a problem of accuracy of the fracture reduction. This study was carried out to demonstrate that the reconstruction of the pelvic brim by approaching the pubo-acetabular fragment plays a role in the accuracy of the reduction of displaced T-shaped acetabular fractures. From 1975 to 1990, a retrospective study was carried out of 22 patients who sustained a displaced T-shaped acetabular fracture. The patients were operated on by open reduction and internal fixation of the ischio-acetabular fragment to the posterior column without restoration of the pelvic brim. Radiographs of the pelvis were reviewed. The result showed that there was displacement of the pubo-acetabular fragment including the medial wall in all cases. As the result of this study, a prospective study between 1990 and 1997 was carried out of 15 patients who sustained displaced T-shaped acetabular fractures including 3 cases with medial displacement of the femoral head. The pubo-acetabular fragment was anatomically reduced and fixed to the anterior column of the acetabulumn as the first approach to restore a disrupted pelvic brim. There, patterns of the acetabular fracture were subsequently re-evaluated especially the ischio-acetabular fragment including the position of the femoral head by using an intraoperative portable X-ray technique. The stability of the hip joint was assessed by hip flexion. The intraoperative radiograph appearances of the ischio-acetabular fragment were visually confirmed by a second surgical exposure. The results showed that the intraoperative radiographs gave spontaneous reduction of the ischio-acetabular fragment in all patients except one. There was a reduction of the displaced femoral head into the hip socket in the three patients. The hip joints were stable in all patients. The second surgical exposure showed that there was good spontaneous reduction of the ischio-acetabular fragment to the posterior column by ligamentotaxis in 14 patients. Therefore, it is not necessary to address the ischio-acetabular fragment. In the exceptional case, the ischio-acetabular fragment was displaced as a free bone which could not be reduced by ligamentotaxis. However, reduction and internal fixation of the ischio-acetabular fragment to the posterior column for complete re-application of the hip joint onto the pelvic ring of this case was facilitated. Postoperative 2 year and 5 year follow-up showed that the fracture had healed without heterotrophic ossification or premature osteoarthrosis of the hip joint. The exceptional case had a broken plate at the anterior column of the acetabulum. Hip function was evaluated clinically using Merle D' Aubigne's hip score. All patients had a "very good score". The study showed that reconstruction of the pelvic brim by anatomical reduction and fixation of the pubo-acetabular fragment to the anterior column plays an important role in the accuracy of fracture reduction of a displaced T-shaped acetabular fracture.

  9. Is Skin Tenting Secondary to Displaced Clavicle Fracture More Than a Theoretical Risk? A Report of 2 Adolescent Cases.

    PubMed

    Chalmers, Peter N; Van Thiel, Geoff S; Ferry, Scott T

    2015-10-01

    While one traditional indication for open reduction and internal fixation (ORIF) of clavicle fractures was tenting of the skin because of concern for an impending open fracture, recent review materials indicate that this complication may only be theoretical. To the best of the authors' knowledge, this complication has never been reported for a midshaft clavicle fracture. We report 2 adolescent cases of displaced, comminuted clavicle fractures in which the skin was initially intact. Both were managed nonoperatively and both secondarily presented with open lesions at the fracture site requiring urgent irrigation and débridement and ORIF. In displaced midshaft clavicle fractures, tenting of the skin sufficient to cause subsequent violation of the soft-tissue envelope is possible and is more than a theoretical risk. At-risk patients (ie, those with a vertically angulated sharp fragment of comminution) should be counseled appropriately and observed closely or considered for primary ORIF.

  10. Use of a real-size 3D-printed model as a preoperative and intraoperative tool for minimally invasive plating of comminuted midshaft clavicle fractures.

    PubMed

    Kim, Hyong Nyun; Liu, Xiao Ning; Noh, Kyu Cheol

    2015-06-10

    Open reduction and plate fixation is the standard operative treatment for displaced midshaft clavicle fracture. However, sometimes it is difficult to achieve anatomic reduction by open reduction technique in cases with comminution. We describe a novel technique using a real-size three dimensionally (3D)-printed clavicle model as a preoperative and intraoperative tool for minimally invasive plating of displaced comminuted midshaft clavicle fractures. A computed tomography (CT) scan is taken of both clavicles in patients with a unilateral displaced comminuted midshaft clavicle fracture. Both clavicles are 3D printed into a real-size clavicle model. Using the mirror imaging technique, the uninjured side clavicle is 3D printed into the opposite side model to produce a suitable replica of the fractured side clavicle pre-injury. The 3D-printed fractured clavicle model allows the surgeon to observe and manipulate accurate anatomical replicas of the fractured bone to assist in fracture reduction prior to surgery. The 3D-printed uninjured clavicle model can be utilized as a template to select the anatomically precontoured locking plate which best fits the model. The plate can be inserted through a small incision and fixed with locking screws without exposing the fracture site. Seven comminuted clavicle fractures treated with this technique achieved good bone union. This technique can be used for a unilateral displaced comminuted midshaft clavicle fracture when it is difficult to achieve anatomic reduction by open reduction technique. Level of evidence V.

  11. Radiological and functional outcomes 2.7 years following conservatively treated completely displaced midshaft clavicle fractures.

    PubMed

    Fuglesang, Hendrik F S; Flugsrud, Gunnar B; Randsborg, Per-Henrik; Stavem, Knut; Utvåg, Stein E

    2016-01-01

    It is unclear whether all completely displaced midshaft clavicle fractures require primary surgical intervention. The aim of this study was to elucidate the radiological and clinical outcomes after conservative treatment, and to identify subgroups at risk of an inferior outcome. Retrospective case series. Level II trauma center. Between 2005 and 2008, 122 patients were conservatively treated for a completely displaced midshaft clavicle fracture of whom 92 were eligible for inclusion in this study. Of these, 59 completed the study after a median of 2.7 years after the fracture (min-max, 1.1-4.9). The patients received the standard treatment administered at our institution at the time: nonsurgically with a sling without physiotherapy. Patients with painful nonunions were subsequently offered surgery. At follow-up, the patients' Disabilities of Arm, Shoulder, and Hand (DASH) and the Constant scores were evaluated. Radiographs were taken at follow-up and compared to those taken acutely. Nonunion was found in 9 of the 59 (15.3%) patients. Twenty-four (24%) patients reported a fair-to-poor DASH score (i.e. >20). Patients with fractures that were vertically displaced by more than 100% (one bone width) were significantly less satisfied than those with fractures vertically displaced at 100% (p = 0.04). Initial shortening of more than 15 mm was not associated with a worse outcome or nonunion. The odds ratio of developing a nonunion increased with age (p = 0.04). By treating completely displaced midshaft clavicle fractures conservatively with a sling and offering plate fixation for eventual painful nonunions, we found a 24% risk of a fair or poor clinical result with a DASH score over 20. A vertical displacement of more than 100 % between the main fragments on the initial radiograph was associated with an inferior clinical outcome in this study. IV.

  12. The nature of a deformation zone and fault rock related to a recent rockburst at Western Deep Levels Gold Mine, Witwatersrand Basin, South Africa

    NASA Astrophysics Data System (ADS)

    Stewart, R. A.; Reimold, W. U.; Charlesworth, E. G.; Ortlepp, W. D.

    2001-07-01

    In August 1998, a major deformation zone was exposed over several metres during mining operations on 87 Level (2463 m below surface) at Western Deep Levels Gold Mine, southwest of Johannesburg, providing a unique opportunity to study the products of a recent rockburst. This zone consists of three shear zones, with dip-slip displacements of up to 15 cm, that are oriented near-parallel to the advancing stope face. Jogs and a highly pulverised, cataclastic 'rock-flour' are developed on the displacement surfaces, and several sets of secondary extensional fractures occur on either side of the shear zones. A set of pinnate (feather) joints intersects the fault surfaces perpendicular to the slip vector. Microscopically, the shear zones consist of two pinnate joint sets that exhibit cataclastic joint fillings; quartz grains display intense intragranular fracturing. Secondary, intergranular extension fractures are associated with the pinnate joints. Extensional deformation is also the cause of the breccia fill of the pinnate joints. The initial deformation experienced by this zone is brittle and tensile, and is related to stresses induced by mining. This deformation has been masked by later changes in the stress field, which resulted in shearing. This deformation zone does not appear to be controlled by pre-existing geological features and, thus, represents a 'burst fracture', which is believed to be related to a seismic event of magnitude ML=2.1 recorded in July 1998, the epicentre of which was located to within 50 m of the study locality.

  13. Periprosthetic Fractures Following Total Knee Arthroplasty

    PubMed Central

    Kim, Nam Ki

    2015-01-01

    Periprosthetic fractures after total knee arthroplasty may occur in any part of the femur, tibia and patella, and the most common pattern involves the supracondylar area of the distal femur. Supracondylar periprosthetic fractures frequently occur above a well-fixed prosthesis, and risk factors include anterior femoral cortical notching and use of the rotational constrained implant. Periprosthetic tibial fractures are frequently associated with loose components and malalignment or malposition of implants. Fractures of the patella are much less common and associated with rheumatoid arthritis, use of steroid, osteonecrosis and malalignment of implants. Most patients with periprosthetic fractures around the knee are the elderly with poor bone quality. There are many difficulties and increased risk of nonunion after treatment because reduction and internal fixation is interfered with by preexisting prosthesis and bone cement. Additionally, previous soft tissue injury is another disadvantageous condition for bone healing. Many authors reported good clinical outcomes after non-operative treatment of undisplaced or minimally displaced periprosthetic fractures; however, open reduction or revision arthroplasty was required in displaced fractures or fractures with unstable prosthesis. Periprosthetic fractures around the knee should be prevented by appropriate technique during total knee arthroplasty. Nevertheless, if a periprosthetic fracture occurs, an appropriate treatment method should be selected considering the stability of the prosthesis, displacement of fracture and bone quality. PMID:25750888

  14. The use of a single titanium microplate in displaced pediatric parasymphysial mandibular fractures.

    PubMed

    Abdullah, Walid A

    2009-07-01

    The objective of this study was to evaluate the use of one titanium microplate in the fixation of displaced pediatric parasymphysial mandibular fractures. The study was conducted on 7 children in the mixed dentition stage with displaced parasymphysial fracture. Patients' age ranged between 5 years 9 months and 8 years 4 months with an average of 7 years 1 month. Fractured bone segments were exposed, reduced and then fixed using 1.5 linear microplates at the inferior border of the mandible using monocortical screws, with 1.5 mm in diameter and 5 mm in length. Stainless steel wire was used as a tension band by ligating the teeth around the fracture line. Patients were followed up for occlusion and stability clinically and radiographically (panoramic X-ray and CT). According to clinical and radiographic post-operative follow-up, none of the patients showed displacement of the fixed bony segments. The present study concluded that using one microplate with 1.5 monocortical microscrews and dental tension band by a stainless steel wire could be adequate for fixing displaced pediatric parasymphysial mandibular fractures. This technique has the following advantages: decreases the amount of titanium used, decreases the risk of injury of the roots and teeth buds, and decreases the cost and time of surgery.

  15. The use of a single titanium microplate in displaced pediatric parasymphysial mandibular fractures

    PubMed Central

    Abdullah, Walid A.

    2009-01-01

    Objective The objective of this study was to evaluate the use of one titanium microplate in the fixation of displaced pediatric parasymphysial mandibular fractures. Materials and methods The study was conducted on 7 children in the mixed dentition stage with displaced parasymphysial fracture. Patients’ age ranged between 5 years 9 months and 8 years 4 months with an average of 7 years 1 month. Fractured bone segments were exposed, reduced and then fixed using 1.5 linear microplates at the inferior border of the mandible using monocortical screws, with 1.5 mm in diameter and 5 mm in length. Stainless steel wire was used as a tension band by ligating the teeth around the fracture line. Patients were followed up for occlusion and stability clinically and radiographically (panoramic X-ray and CT). Results According to clinical and radiographic post-operative follow-up, none of the patients showed displacement of the fixed bony segments. Conclusion The present study concluded that using one microplate with 1.5 monocortical microscrews and dental tension band by a stainless steel wire could be adequate for fixing displaced pediatric parasymphysial mandibular fractures. This technique has the following advantages: decreases the amount of titanium used, decreases the risk of injury of the roots and teeth buds, and decreases the cost and time of surgery. PMID:23960466

  16. [Arthroscopically Assisted Minimally Invasive Fixation of a Type D2c Scapular Fracture].

    PubMed

    Kornherr, Patrick; Konerding, Christiane; Kovacevic, Mark; Wenda, Klaus

    2018-06-12

    Fractures of the scapula are rare and have an incidence of 1% of all fractures. Publications highlight glenoid rim fractures. Classification by Ideberg and Euler and Rüdi are accepted. Euler and Rüdi describe three extra-articular and two intra-articular fracture patterns. The indications for surgery are displaced glenoid fractures, scapula tilt of more than 40° and injuries to the superior shoulder suspensory complex. We describe a case of a 22 year old man, who while cycling collided with a moving car due to wet roads. After his admission to hospital as a polytraumatised patient, the trauma CT-Scan showed haemothorax with several associated rip fractures, displaced humeral shaft fracture and fractures of the acromion and glenoid, classified as type D2c according to Euler and Rüdi. Following damage control principles, drainage of the haemothorax was already performed in the ER and surgical treatment of the displaced humeral shaft fracture was performed on the day of admission. No peripheral neurological deficits were evident. After pulmonary stabilisation, surgery was performed 6 days later on the glenoid and acromion fracture, which in conjunction may be regarded as an injury to the superior shoulder suspensory complex. We performed an arthroscopically-assisted screw fixation of the glenoid fracture (type D2c according to Euler and Rüdi) and an ORIF procedure at the acromion. Postoperative rehabilitation was performed with passive abduction and elevation up to 90° for the first two weeks and active abduction an elevation up to 90° for weeks 3 to 6. Full ROM was allowed at week 7. Articular fractures of the glenoid are rare and mainly seen as rim fractures. The indications for surgery are displaced articular fractures and injury to the superior shoulder suspensory complex. As demonstrated by this article, type D2c fractures according to Euler and Rüdi can be treated effectively as an arthroscopically-assisted screw fixation procedure. Georg Thieme Verlag KG Stuttgart · New York.

  17. Enhanced oil displacement by nanofluid's structural disjoining pressure in model fractured porous media.

    PubMed

    Zhang, Hua; Ramakrishnan, T S; Nikolov, Alex; Wasan, Darsh

    2018-02-01

    Nanofluids for improved oil recovery has been demonstrated through laboratory corefloods. Despite numerous experimental studies, little is known about the efficacy of nanofluids in fractured systems. Here, we present studies of nanofluid injection in fractured porous media (both water-wet and oil-wet) formed by sintering borosilicate glass-beads around a dissolvable substrate. The fracture inside the porous medium is characterized and visualized using a high resolution X-ray microtomography. Based on a simple displacement theory, the nanofluid injection is conducted at a rate where structural disjoining pressure driven oil recovery is operational. An additional 23.8% oil was displaced using nanofluid after brine injection with an overall recovery efficiency of 90.4% provided the matrix was in its native wettability state. But only 6% additional oil was displaced by nanofluid following brine injection when the bead-pack was rendered oil-wet. Nanofluids appear to be a good candidate for enhanced oil recovery (EOR) in fractured water-wet to weakly water-wet media but not necessarily for strongly oil-wet systems. Our laboratory studies enable us to understand limitations of nanofluids for improving oil recovery in fractured media. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Mesoscale Fracture Analysis of Multiphase Cementitious Composites Using Peridynamics

    PubMed Central

    Yaghoobi, Amin; Chorzepa, Mi G.; Kim, S. Sonny; Durham, Stephan A.

    2017-01-01

    Concrete is a complex heterogeneous material, and thus, it is important to develop numerical modeling methods to enhance the prediction accuracy of the fracture mechanism. In this study, a two-dimensional mesoscale model is developed using a non-ordinary state-based peridynamic (NOSBPD) method. Fracture in a concrete cube specimen subjected to pure tension is studied. The presence of heterogeneous materials consisting of coarse aggregates, interfacial transition zones, air voids and cementitious matrix is characterized as particle points in a two-dimensional mesoscale model. Coarse aggregates and voids are generated using uniform probability distributions, while a statistical study is provided to comprise the effect of random distributions of constituent materials. In obtaining the steady-state response, an incremental and iterative solver is adopted for the dynamic relaxation method. Load-displacement curves and damage patterns are compared with available experimental and finite element analysis (FEA) results. Although the proposed model uses much simpler material damage models and discretization schemes, the load-displacement curves show no difference from the FEA results. Furthermore, no mesh refinement is necessary, as fracture is inherently characterized by bond breakages. Finally, a sensitivity study is conducted to understand the effect of aggregate volume fraction and porosity on the load capacity of the proposed mesoscale model. PMID:28772518

  19. Is Bone Grafting Necessary in the Treatment of Malunited Distal Radius Fractures?

    PubMed Central

    Disseldorp, Dominique J. G.; Poeze, Martijn; Hannemann, Pascal F. W.; Brink, Peter R. G.

    2015-01-01

    Background Open wedge osteotomy with bone grafting and plate fixation is the standard procedure for the correction of malunited distal radius fractures. Bone grafts are used to increase structural stability and to enhance new bone formation. However, bone grafts are also associated with donor site morbidity, delayed union at bone–graft interfaces, size mismatch between graft and osteotomy defect, and additional operation time. Purpose The goal of this study was to assess bone healing and secondary fracture displacement in the treatment of malunited distal radius fractures without the use of bone grafting. Methods Between January 1993 and December 2013, 132 corrective osteotomies and plate fixations without bone grafting were performed for malunited distal radius fractures. The minimum follow-up time was 12 months. Primary study outcomes were time to complete bone healing and secondary fracture displacement. Preoperative and postoperative radiographs during follow-up were compared with each other, as well as with radiographs of the uninjured side. Results All 132 osteotomies healed. In two cases (1.5%), healing took more than 4 months, but reinterventions were not necessary. No cases of secondary fracture displacement or hardware failure were observed. Significant improvements in all radiographic parameters were shown after corrective osteotomy and plate fixation. Conclusion This study shows that bone grafts are not required for bone healing and prevention of secondary fracture displacement after corrective osteotomy and plate fixation of malunited distal radius fractures. Level of evidence Therapeutic, level IV, case series with no comparison group PMID:26261748

  20. Comminuted supracondylar femoral fractures: a biomechanical analysis comparing the stability of medial versus lateral plating in axial loading.

    PubMed

    Briffa, Nikolai; Karthickeyan, Raju; Jacob, Joshua; Khaleel, Arshad

    2016-11-01

    The aim of this study was to compare the biomechanical properties of medial and lateral plating of a medially comminuted supracondylar femoral fracture. A supracondylar femoral fracture model comparing two fixation methods was tested cyclically in axial loading. One-centimetre supracondylar gap osteotomies were created in six synthetic femurs approximately 6 cm proximal to the knee joint. There were two constructs investigated: group 1 and group 2 were stabilized with an 8-hole LC-DCP, medially and laterally, respectively. Both construct groups were axially loaded. Global displacement (total length), wedge displacement, bending moment and strain were measured. Medial plating showed a significantly decreased displacement, bending moment and strain at the fracture site in axial loading. Medial plating of a comminuted supracondylar femur fracture is more stable than lateral plating.

  1. Hydraulic properties of 3D rough-walled fractures during shearing: An experimental study

    NASA Astrophysics Data System (ADS)

    Yin, Qian; Ma, Guowei; Jing, Hongwen; Wang, Huidong; Su, Haijian; Wang, Yingchao; Liu, Richeng

    2017-12-01

    This study experimentally analyzed the influence of shear processes on nonlinear flow behavior through 3D rough-walled rock fractures. A high-precision apparatus was developed to perform stress-dependent fluid flow tests of fractured rocks. Then, water flow tests on rough-walled fractures with different mechanical displacements were conducted. At each shear level, the hydraulic pressure ranged from 0 to 0.6 MPa, and the normal load varied from 7 to 35 kN. The results show that (i) the relationship between the volumetric flow rate and hydraulic gradient of rough-walled fractures can be well fit using Forchheimer's law. Notably, both the linear and nonlinear coefficients in Forchheimer's law decrease during shearing; (ii) a sixth-order polynomial function is used to evaluate the transmissivity based on the Reynolds number of fractures during shearing. The transmissivity exhibits a decreasing trend as the Reynolds number increases and an increasing trend as the shear displacement increases; (iii) the critical hydraulic gradient, critical Reynolds number and equivalent hydraulic aperture of the rock fractures all increase as the shear displacement increases. When the shear displacement varies from 0 to 15 mm, the critical hydraulic gradient ranges from 0.3 to 2.2 for a normal load of 7 kN and increases to 1.8-8.6 for a normal load of 35 kN; and (iv) the Forchheimer law results are evaluated by plotting the normalized transmissivity of the fractures during shearing against the Reynolds number. An increase in the normal load shifts the fitted curves downward. Additionally, the Forchheimer coefficient β decreases with the shear displacement but increases with the applied normal load.

  2. Fracture characterization of human cortical bone under mode II loading using the end-notched flexure test.

    PubMed

    Silva, F G A; de Moura, M F S F; Dourado, N; Xavier, J; Pereira, F A M; Morais, J J L; Dias, M I R; Lourenço, P J; Judas, F M

    2017-08-01

    Fracture characterization of human cortical bone under mode II loading was analyzed using a miniaturized version of the end-notched flexure test. A data reduction scheme based on crack equivalent concept was employed to overcome uncertainties on crack length monitoring during the test. The crack tip shear displacement was experimentally measured using digital image correlation technique to determine the cohesive law that mimics bone fracture behavior under mode II loading. The developed procedure was validated by finite element analysis using cohesive zone modeling considering a trapezoidal with bilinear softening relationship. Experimental load-displacement curves, resistance curves and crack tip shear displacement versus applied displacement were used to validate the numerical procedure. The excellent agreement observed between the numerical and experimental results reveals the appropriateness of the proposed test and procedure to characterize human cortical bone fracture under mode II loading. The proposed methodology can be viewed as a novel valuable tool to be used in parametric and methodical clinical studies regarding features (e.g., age, diseases, drugs) influencing bone shear fracture under mode II loading.

  3. Shaft-Condylar Angle for surgical correction in neglected and displaced lateral humeral condyle fracture in children.

    PubMed

    Mulpruek, Pornchai; Angsanuntsukh, Chanika; Woratanarat, Patarawan; Sa-Ngasoongsong, Paphon; Tawonsawatruk, Tulyapruek; Chanplakorn, Pongsthorn

    2015-09-01

    To assess the outcome after using the Shaft-Condylar angle (SCA) as intraoperative reference for sagittal plane correction in displaced lateral humeral condyle fractures in children presented 3-weeks after injury. Ten children, with delayed presentation of a displaced lateral humeral condyle fracture and undergoing surgery during 1999-2011, were reviewed. The goal was to obtain a smooth articular surface with an intraoperative SCA of nearly 40° and nearest-anatomical carrying angle. They were allocated into two groups according to the postoperative SCA [Good-reduction group (SCA=30-50°), and Bad-reduction group (SCA<30°, >50°)] and the final outcomes were then compared. All fractures united without avascular necrosis. The Good-reduction group (n=7) showed a significant improvement in final range of motion and functional outcome compared to the Bad-reduction group (n=3) (p=0.02). However, there was no significant difference in pain, carrying angle and overall outcome between both groups. SCA is a possible intraoperative reference for sagittal alignment correction in late presented displaced lateral humeral condyle fractures.

  4. Hemodynamic Deterioration in Lateral Compression Pelvic Fracture After Prehospital Pelvic Circumferential Compression Device Application.

    PubMed

    Garner, Alan A; Hsu, Jeremy; McShane, Anne; Sroor, Adam

    Increased fracture displacement has previously been described with the application of pelvic circumferential compression devices (PCCDs) in patients with lateral compression-type pelvic fracture. We describe the first reported case of hemodynamic deterioration temporally associated with the prehospital application of a PCCD in a patient with a complex acetabular fracture with medial displacement of the femoral head. Active hemorrhage from a site adjacent to the acetabular fracture was subsequently demonstrated on angiography. Caution in the application of PCCDs to patients with lateral compression-type fractures is warranted. Copyright © 2017 Air Medical Journal Associates. All rights reserved.

  5. Manipulation of nasal fractures with local anaesthetic: a 'how to do it' with online video tutorial.

    PubMed

    Repanos, Costa; Anderson, Daniel; Earnshaw, James; Mitchell, David; Coman, William

    2010-06-01

    Nasal fractures are the most common facial fractures and displaced fractures may cause considerable cosmetic concern. Traditionally, displaced nasal fractures have been manipulated under general anaesthesia (GA) performed within 2 weeks of the injury. Despite evidence for the benefit of local anaesthesia (LA), nasal fractures are still most commonly reduced under GA. We have presented a method of reduction of simple nasal fractures under LA in an outpatient setting. This has the advantage of being painless, simple to attempt and cost-effective. If reduction is inadequate then a general anaesthetic reduction is still possible. A recent comprehensive systematic review of all the available evidence did not show any significant difference (in terms of cosmesis, pain or nasal obstruction) between using LA and GA methods and highlighted the evidence base to support LA. We describe our method of assessment and treatment of displaced nasal fractures and provide an online tutorial (http://sciencestage.com/v/22194/local-anaesthetic-nasal-fracture-reduction.html). It is important to keep in mind that any concerns should be referred to an otolaryngology specialist for further management and that practitioners attempting this technique should first receive training from an otolaryngologist.

  6. High incidence of osteochondral lesions after open reduction and internal fixation of displaced ankle fractures: Medium-term follow-up of 100 cases.

    PubMed

    Regier, Marc; Petersen, Jan Philipp; Hamurcu, Ahmet; Vettorazzi, Eik; Behzadi, Cyrus; Hoffmann, Michael; Großterlinden, Lars G; Fensky, Florian; Klatte, Till Orla; Weiser, Lukas; Rueger, Johannes M; Spiro, Alexander S

    2016-03-01

    The incidence of osteochondral lesions (OCLs) in association with displaced ankle fractures has only been examined in two previous studies. In both studies magnetic resonance imaging (MRI) was performed prior to open reduction and internal fixation (ORIF). Because MRI may overdiagnose or overestimate the extent of OCLs in an acute trauma setting the aim of this study was to determine the incidence of OCLs after ORIF of displaced ankle fractures using MRI at medium-term follow-up, and to analyse if the severity of fracture or the clinical outcome correlates with the incidence of OCLs. Following institutional review board approval a total of 100 patients (mean age, 41.3 years; range, 17.9-64.3 years) with a displaced ankle fracture who had undergone ORIF according to the AO principles were included in this study. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score was used to quantify the clinical outcome and MR images were evaluated for OCLs of the talus and distal tibia after a mean of 34.5 months (range, 17.5-54.1 months). OCLs were found in 40.4% of the patients. Logistic regression revealed a significant correlation between the severity of fracture and the incidence of OCLs. Patients with a trimalleolar fracture (p=0.04) or an ankle fracture dislocation (p=0.003) had a significantly higher risk for developing an OCL compared to those with a type B fracture. Logistic regression also demonstrated a significant correlation between the clinical outcome (AOFAS score) and the incidence of OCLs (p=0.01). The risk for developing an OCL increases up to 5.6% when the AOFAS score decreases by one point. OCLs were frequently found in association with acute ankle fractures at medium-term follow-up, and the severity of fracture was associated with an increased number of OCLs. Considering the disadvantages of MRI including the high cost and limited availability, the results of this study may help to explain why anatomic surgical realignment of displaced ankle fractures may still be associated with poor clinical outcomes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Surgical and functional outcomes after operative management of complex and displaced intra-articular glenoid fractures.

    PubMed

    Anavian, Jack; Gauger, Erich M; Schroder, Lisa K; Wijdicks, Coen A; Cole, Peter A

    2012-04-04

    Operative treatment is indicated for displaced fractures of the glenoid fossa. However, little is known regarding functional outcomes in these patients. This study assesses surgical and functional results after treatment of displaced, high-energy, complex, intra-articular glenoid fractures. Thirty-three patients with displaced intra-articular fractures of the glenoid were treated surgically between 2002 and 2009. The indications for operative treatment included articular fracture gap or step-off of ≥ 4 mm. Twenty-five patients also had extra-articular scapular involvement. A posterior approach was utilized in twenty-one patients, an anterior approach in seven, and a combined approach in five. Functional outcomes, including Disabilities of the Arm, Shoulder and Hand (DASH) and Short Form-36 (SF-36) scores, shoulder motion and strength, and return to work and/or activities, were obtained for thirty patients (91%). At a mean follow-up of twenty-seven months (range, twelve to seventy-three months), all patients had radiographic union of the fracture. The mean DASH score was 10.8 (range, 0 to 42). All mean SF-36 subscores were comparable with those of the normal population. Twenty-six patients (87%) were pain-free at the time of follow-up, and four had mild pain with prolonged activity. Twenty-seven (90%) of thirty patients returned to their preinjury level of work and/or activities. Our data suggest that surgical treatment for complex, displaced intra-articular glenoid fractures with or without involvement of the scapular neck and body can be associated with good functional outcomes and a low complication rate.

  8. Plating of patella fractures: techniques and outcomes.

    PubMed

    Taylor, Benjamin C; Mehta, Sanjay; Castaneda, Joaquin; French, Bruce G; Blanchard, Chris

    2014-09-01

    Operative treatment of displaced patella fractures with tension band fixation remains the gold standard, but is associated with a significant rate of complications and symptomatic implants. Despite the evolution of tension band fixation to include cannulated screws, surprisingly little other development has been made to improve overall patient outcomes. In this article, we present the techniques and outcomes of patella plating for displaced patella fractures and patella nonunions.

  9. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study.

    PubMed

    Burgers, P T P W; Hoogendoorn, M; Van Woensel, E A C; Poolman, R W; Bhandari, M; Patka, P; Van Lieshout, E M M

    2016-06-01

    The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost awareness. The absolute number of hip fractures is rising and increases the already significant burden on society. The aim of this study was to determine the mean total medical costs per patient for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The population was the Dutch sample of an international randomized controlled trial consisting of femoral neck fracture patients treated with hemi- or total hip arthroplasty. Patient data and health care utilization were prospectively collected during a total follow-up period of 2 years. Costs were separated into costs for hospital care during primary stay, hospital costs for clinical follow-up, and costs generated outside the hospital during rehabilitation. Multiple imputations were used to account for missing data. Data of 141 participants (mean age 81 years) were included in the analysis. The 2-year mortality rate was 19 %. The mean total cost per patient after 10 weeks of follow-up was €15,216. After 1 and 2 years of follow-up the mean total costs were €23,869 and €26,399, respectively. Rehabilitation was the main cost determinant, and accounted for 46 % of total costs. Primary hospital admission days accounted for 22 % of the total costs, index surgery for 11 %, and physical therapy for 7 %. The main cost determinants for hemi- or total hip arthroplasty after treatment of displaced femoral neck fractures (€26,399 per patient until 2 years) were rehabilitation and nursing homes. Most of the costs were made in the first year. Reducing costs after hip fracture surgery should focus on improving the duration and efficiency of the rehabilitation phase.

  10. Modified tension band wiring of medial malleolar ankle fractures.

    PubMed

    Georgiadis, G M; White, D B

    1995-02-01

    Twenty-two displaced medial malleolar ankle fractures that were treated surgically using the modified tension band method of Cleak and Dawson were retrospectively reviewed at an average follow-up of 25 months. The technique involves the use of a screw to anchor a figure-of-eight wire. There were no malreductions and all fractures healed. Problems with the technique included technical errors with hardware placement, medial ankle pain, and asymptomatic wire migration. Despite this, modified tension band wiring remains an acceptable method for fixation of selected displaced medial malleolar fractures. It is especially suited for small fracture fragments and osteoporotic bone.

  11. Stabilization of displaced articular fragments in calcaneal fractures using bioabsorbable pin fixation: a technique guide.

    PubMed

    Min, William; Munro, Mark; Sanders, Roy

    2010-12-01

    Successful operative intervention in displaced intra-articular calcaneal fractures depends in part on the maintenance of an anatomic reduction of the posterior facet. This guide describes our use of bioabsorbable implants to solve this problem.

  12. Permeability of three-dimensional rock masses containing geomechanically-grown anisotropic fracture networks

    NASA Astrophysics Data System (ADS)

    Thomas, R. N.; Ebigbo, A.; Paluszny, A.; Zimmerman, R. W.

    2016-12-01

    The macroscopic permeability of 3D anisotropic geomechanically-generated fractured rock masses is investigated. The explicitly computed permeabilities are compared to the predictions of classical inclusion-based effective medium theories, and to the permeability of networks of randomly oriented and stochastically generated fractures. Stochastically generated fracture networks lack features that arise from fracture interaction, such as non-planarity, and termination of fractures upon intersection. Recent discrete fracture network studies include heuristic rules that introduce these features to some extent. In this work, fractures grow and extend under tension from a finite set of initial flaws. The finite element method is used to compute displacements, and modal stress intensity factors are computed around each fracture tip using the interaction integral accumulated over a set of virtual discs. Fracture apertures emerge as a result of simulations that honour the constraints of stress equilibrium and mass conservation. The macroscopic permeabilities are explicitly calculated by solving the local cubic law in the fractures, on an element-by-element basis, coupled to Darcy's law in the matrix. The permeabilities are then compared to the estimates given by the symmetric and asymmetric versions of the self-consistent approximation, which, for randomly fractured volumes, were previously demonstrated to be most accurate of the inclusion-based effective medium methods (Ebigbo et al., Transport in Porous Media, 2016). The permeabilities of several dozen geomechanical networks are computed as a function of density and in situ stresses. For anisotropic networks, we find that the asymmetric and symmetric self-consistent methods overestimate the effective permeability in the direction of the dominant fracture set. Effective permeabilities that are more strongly dependent on the connectivity of two or more fracture sets are more accurately captured by the effective medium models.

  13. Radiographic Measurement of Displacement in Acetabular Fractures: A Systematic Review of the Literature.

    PubMed

    Dodd, Andrew; Osterhoff, Georg; Guy, Pierre; Lefaivre, Kelly A

    2016-06-01

    To report methods of measurement of radiographic displacement and radiographic outcomes in acetabular fractures described in the literature. A systematic review of the English literature was performed using EMBASE and Medline in August 2014. Inclusion criteria were studies of operatively treated acetabular fractures in adults with acute (<6 weeks) open reduction and internal fixation that reported radiographic outcomes. Exclusion criteria included case series with <10 patients, fractures managed >6 weeks from injury, acute total hip arthroplasty, periprosthetic fractures, time frame of radiographic outcomes not stated, missing radiographic outcome data, and non-English language articles. Basic information collected included journal, author, year published, number of fractures, and fracture types. Specific data collected included radiographic outcome data, method of measuring radiographic displacement, and methods of interpreting or categorizing radiographic outcomes. The number of reproducible radiographic measurement techniques (2/64) and previously described radiographic interpretation methods (4) were recorded. One radiographic reduction grading criterion (Matta) was used nearly universally in articles that used previously described criteria. Overall, 70% of articles using this criteria documented anatomic reductions. The current standard of measuring radiographic displacement in publications dealing with acetabulum fractures almost universally lacks basic description, making further scientific rigor, such as testing reproducibility, impossible. Further work is necessary to standardize radiographic measurement techniques, test their reproducibility, and qualify their validity or determine which measurements are important to clinical outcomes. Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  14. Urological injuries associated with pelvic fractures: A case report of a detached bone segment inside the bladder.

    PubMed

    Alfayez, Saud M; Allimmia, Khalid; Alshammri, Ahmad; Serro, Firas; Almogbel, Rakan; Bin Dous, Abdullah; Almannie, Raed; Palencia, Jesús

    2016-01-01

    Urological injuries in pelvic fractures are noticed in 6-15% of the cases. The bladder, due to its anatomical position, is prone to rupture in pelvic fractures. The majority of urinary bladder injuries are either extraperitoneal or intraperitoneal. Nonetheless, both types can occur simultaneously in 6% of the cases. A 45-year-old male was brought to our emergency department after being struck by an automobile. In the absence of signs of urethral injury, a Foley's catheter was inserted revealing gross hematuria. The radiological assessment showed bilateral non-displacement sacral wing fractures, bilateral non-displacement anterior column fractures and bilateral comminuted superior and inferior pubic rami fractures, with a detached pubic bone fragment displaced posteriorly. A CT cystogram was performed showing intraperitoneal and extraperitoneal extravasation of contrast. The patient was taken to surgery. A sharp-edged bony fragment was discovered inside the bladder. A two-layer closure of the bladder was performed. Pelvic fractures with concomitant lower urinary tract injuries are associated with high morbidity and mortality. The signs indicative of bladder rupture include a more than one centimeter diastasis of the symphysis pubis and a displaced fracture of more than one centimeter involving the obturator ring. However, the signs may not be present as in our case. This unusual case illustrates the potential risk of bladder injury following stable pelvic fractures through a detached bone segment. It also emphasizes on having a high index of suspicion. The teamwork and multidisciplinary approach are essential for an optimal outcome. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Basic principles of fracture treatment in children.

    PubMed

    Ömeroğlu, Hakan

    2018-04-01

    This review aims to summarize the basic treatment principles of fractures according to their types and general management principles of special conditions including physeal fractures, multiple fractures, open fractures, and pathologic fractures in children. Definition of the fracture is needed for better understanding the injury mechanism, planning a proper treatment strategy, and estimating the prognosis. As the healing process is less complicated, remodeling capacity is higher and non-union is rare, the fractures in children are commonly treated by non-surgical methods. Surgical treatment is preferred in children with multiple injuries, in open fractures, in some pathologic fractures, in fractures with coexisting vascular injuries, in fractures which have a history of failed initial conservative treatment and in fractures in which the conservative treatment has no/little value such as femur neck fractures, some physeal fractures, displaced extension and flexion type humerus supracondylar fractures, displaced humerus lateral condyle fractures, femur, tibia and forearm shaft fractures in older children and adolescents and unstable pelvis and acetabulum fractures. Most of the fractures in children can successfully be treated by non-surgical methods.

  16. [Pathological fractures of the femoral neck in hemodialyzed patients. Apropos of 26 cases].

    PubMed

    Hardy, P; Benoit, J; Donneaud, B; Jehanno, P; Lortat-Jacob, A

    1994-01-01

    This study is based on a retrospective analysis of 26 pathological fractures of the femoral neck in 19 chronic haemodialysis patients. The purpose of this study is to analyze the epidemiological and etiological factors of these fractures in relation to osteo-arthropathy of the dialyzed patient, as well as the results of various treatments, both curative and preventive. 26 pathological fractures of the femoral neck appeared in 19 chronic haemodialysis patients, 11 men and 8 women, 6 patients presented bilateral fractures. The patient's average age at the time of the fracture was 61 years (27 to 82). The average duration of dialysis was 11 years with a minimum of 2 years and a maximum of 21 years. Hyper parathyroidism was found in 14 patients, aluminic intoxication in 6 and amyloidosis at the level of the coxo-femoral joint 18 times. Surgical treatment consisted of 6 osteosynthesis, 2 cephalic arthroplasties, 13 modular arthroplasties and 5 total hip arthroplasties. For each case, we studied the presence of necrosis of the femoral neck due to aluminic intoxication, osteoporosis due to hyperparathyroidism and also the presence of amyloidosis without aluminic intoxication. Cortisonic necrosis and porosis was found 4 times out of 26 cases, hyperparathyroidism once, aluminic osteomalacy 3 times and beta-2-microglobulin amyloid 18 times. Amyloidosis remains the most frequent etiological factor. All patients had been operated for median nerve compression in the carpal tunnel, usually 2.5 years before appearance of the pathological fracture. Non surgical treatment was used 5 times in undisplaced fractures without any sign of amyloidosis and was successful 3 times and unsuccessful twice necessitating a new operation by osteosynthesis. Out of 6 osteosynthesis performed for fractures either with little or no displacement we observed 4 failures, all of them in the cases with intra-osseous amyloidosis. Best results were obtained by arthroplasties. Modular arthroplasty has given us 11 long term excellent results in 11 of 13 cases. The analysis of etiological factors shows two very different groups. The first one consisted of 8 fractures without coxofemoral amyloidosis. The average duration of dialysis was 5 years, average age, 44 years. Etiology was 3 times aluminic osteomalacy, once the only factor found was osteoporosis and 4 times necrosis and porosis as a complication, not of haemodialysis but of renal transplantation with concomittant corticosteroid treatment. The second group consisted of 18 fractures with hip amyloidosis in 14 patients. The average age was 63.5 years, the dialysis duration was 11.5 years, the two extremes 5 and 21 years. Etiology was beta-2-microglobulin amylosis. The pathological fracture was due to the presence of voluminous subchondral amyloidosis geodes. Amyloidosis always associated with hyperparathyroidism and aluminic intoxication in one of 3 cases. Osteosynthesis gave good results only in cases presenting no intra-osseous amyloidosis. Modular arthroplasty has allowed us to obtain excellent long term functional results with simpler outcome. Total arthroplasty should be used only for evident acetabular involvement. Amyloidosis remains the etiological factor most frequently found in pathological fractures of the femoral neck in chronic haemodialysis patients. The study of the etiological factors is essential since they will guide us in the choice of the mode or treatment. It is totally licit to propose conservative treatment for non displaced fractures without osseous amylosis. In all other cases, prosthetic replacement is necessary and osteosynthesis contra-indicated. When the acetabulum is not altered a modular arthroplasty must be used. We do not recommend preventive surgical treatment for patients having a threatening geode of the femoral neck as all osteosynthesis realized on amyloidotic bone, even without any displacement, resulted

  17. The second fracture of the same clavicle: prevalence and fracture configurations.

    PubMed

    Asavamongkolkul, Apichat; Harnroongroj, Thos; Suteeraporn, Wuttipon; Sudjai, Narumol; Harnroongroj, Thossart

    2012-12-01

    To study second fracture at the same clavicle including prevalence, fracture configurations related to malunion types of the first fracture, and healing. Between 2008 and 2011, the authors reviewed medical records and radiographs of the clavicles of patients who sustained acute clavicular fractures from motorcycle accident. Second fracture at the same clavicle and prevalence were studied. Malunion of the first fracture of the same clavicle were typed and configurations of the second fracture at the same clavicles were described related to type of the malunion. There were 552 clavicular fractures. Four cases of which sustained a second fracture at the same clavicles. Malunion of the first clavicular fracture of the four cases were typed: type I, extension, type II, flexion, and type III, bayonet. There were one, two, and one case of second clavicular fractures of the type I, II, and III clavicular malunion. The configuration of second clavicular fracture of the type I malunion clavicle is located at lateral fragment, inferior displacement, and dorsal angulation with dorsal cortex conminution. The type II malunion clavicle is located at lateral fragment with minimal displacement. For the type III malunion clavicle, the second fracture is located at medial fragment with mild inferior displacement and inferior angulation. The four cases of the second fractures of the same clavicles healed within two months without complication. The prevalence of second fracture at the same clacicles was 7.2:1000. The three types of the first fracture malunion were extension, flexion, and bayonet. The configuration of the second fracture at the same clavicles depends on malunion types of the first clavicular fracture. They healed without complication.

  18. Hard tissue pediatric facial trauma: a review.

    PubMed

    Hogg, Nicholas J V; Horswell, Bruce B

    2006-01-01

    Although hard tissue injuries are uncommon in the pediatric patient, dentists may be involved in the initial assessment of these patients. In this paper, we review fractures of the facial skeleton with a focus on dentoalveolar injuries. Minimally displaced fractures in pediatric patients can be managed conservatively, while displaced fractures may require open approaches and rigid fixation. New fixation stratagems are presented, and possible facial growth disturbances resulting from trauma are discussed.

  19. Is Augmented LISS Plating Biomechanically Advantageous Over Conventional LISS Plating In Unstable Osteoporotic Distal Femoral Fractures?

    PubMed

    Todorov, Dimitar; Zderic, Ivan; Richards, R Geoff; Lenz, Mark; Knobe, Matthias; Enchev, Dian; Baltov, Asen; Gueorguiev, Boyko; Stoffel, Karl

    2018-05-10

    Treatment of complex osteoporotic distal femur fractures with the Less Invasive Stabilization System (LISS) has been associated with high complication rates. The aim of this study was to investigate the biomechanical competence of two different techniques of augmented versus conventional LISS plating. Unstable distal femoral fracture AO/OTA 33-A3 was created via osteotomies in artificial femora simulating osteoporotic bone. Three study groups, consisting of 10 specimens each, were created for instrumentation with either LISS plate, LISS plate with additional polylactide intramedullary graft, or LISS plate plus medial locking plate (double plating). All specimens were non-destructively tested under axial (20-150N) and torsional (0-4Nm) quasi-static loading. Each construct was tested with two different working length (WL) configurations (long and short) of the LISS plate. Relative movements between the most medial superior and inferior osteotomy aspects were investigated via three-dimensional motion tracking analysis. Double plating revealed significantly smaller longitudinal and shear displacement than the other two techniques (P≤0.001). In addition, LISS plus graft fixation was with significantly less longitudinal displacement in comparison to conventional LISS plating (P < 0.001). Long WL resulted in significantly higher longitudinal and shear displacement compared to short WL for LISS and LISS plus graft (P≤0.032), but not for double plating (P > 0.999). In conclusion, intramedullary grafting resulted in significantly increased fracture stability under axial loading in comparison to conventional LISS plating. Although it was not efficient enough to provide comparable stability to double plating, intramedullary grafting may be considered as a useful biological alternative to the latter in a surgeon's armamentarium. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Brachial Plexus Injury in a 6-Year-Old Boy with 100% Displaced Proximal Humeral Metaphyseal Fracture: A Case Presentation.

    PubMed

    Jovanovich, Elizabeth Nora; Howard, James F

    2017-12-01

    Posttraumatic brachial plexopathies can occur following displaced proximal humeral fractures, causing profound functional deficits. Described here is an unusual case of a displaced proximal humeral metaphyseal fracture in a young child. The patient underwent closed reduction and serial casting, but hand weakness and forearm sensory loss persisted. Needle electromyography localized the injury to the mid/proximal arm near the fracture site, resulting in damage to the posterior and medial cords of the brachial plexus with profound involvement of the radial, ulnar, and median nerves and sparing of the axillary nerve. After months of occupational therapy, hand strength improved, with a nearly full return of function. V. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  1. Operative treatment of sternal fractures.

    PubMed

    Al-Qudah, Abdullah

    2006-10-01

    Four patients with displaced sternal fractures complained of intractable pain following road traffic accidents. They all had bone deformities, but only one had associated traumatic injuries. All patients underwent operative reduction and fixation of the fractured sternum using a T-shaped compression-tension stainless steel plate and screws. Pain relief was often dramatic and all patients progressed to sternal union. None required reoperation. No infections occurred. Two plates have subsequently been removed. On follow-up, all patients had excellent results. Sternal plating, which is based on the tension-band principle, is an effective treatment for displaced sternal fractures.

  2. Application of a Shape-Memory Alloy Concentrator in Displaced Patella Fractures: Technique and Long-Term Results.

    PubMed

    Zhang, Yuntong; Wang, Panfeng; Xia, Yan; Zhou, Panyu; Xie, Yang; Xu, Shuogui; Zhang, Chuncai

    2017-02-01

    Operative treatment is usually recommended in displaced patella fractures. Several techniques have been advocated for internal fixation of patella fractures. Despite the relatively good clinical outcomes that have been demonstrated in many studies, postoperative morbidities such as fixation failure, nonunion, infection, and knee stiffness are not uncommon. We present a new alternative treatment technique for displaced patellar fractures. Between April 1995 and May 2005, we used the Nitinol Patella Concentrator (NTPC) to treat 156 consecutive patients with displaced patellar fractures. Injuries arose from vehicular accidents in 56 (35.9%) cases, direct falls onto the knee in 85 (54.5%) cases, and sports injuries in 15 (9.6%) cases. The mean patient age was 46.3 years (range, 25-77 years). Clinical assessments were made using the Böstman knee score and the MOS SF-36 questionnaire (Medical Outcomes Study 36-item short-form health survey), which were both recorded at the final follow-up visit. The mean follow-up was 7.3 years (range, 6-17 years). At the final follow-up, the Böstman knee scores were excellent in 88 cases (28-30), good in 55 (20-27), and unsatisfactory in 13 (<20). According to the MOS SF-36 evaluation, the average score was 84.5 (range, 62-91). Treatment of patellar fracture with the NTPC not only may serve as an effective and rigid fixation method in multifragmented displaced and inferior pole fractures, but also may provide continuous concentrative compression during the osseous healing process. Thus, use of the NTPC may help restore the functional integrity of the extensor mechanism and permit early rehabilitation with a lower incidence of postoperative complications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Radiographic follow-up of 84 operatively treated scapula neck and body fractures.

    PubMed

    Cole, Peter A; Gauger, Erich M; Herrera, Diego A; Anavian, Jack; Tarkin, Ivan S

    2012-03-01

    Certain scapula fractures may warrant surgical management to restore shoulder anatomy and promote optimal function. The purpose of this study is to determine the early radiographic follow-up of open reduction internal fixation (ORIF) for displaced, scapular fractures involving the glenoid neck and body. Eighty-four patients with a scapula body or neck fracture (with or without articular involvement) underwent ORIF between 2002 and 2010 at a single level I trauma centre. This study represents a retrospective review of data prospectively collected into a dedicated scapula fracture database. All patients met at least one of the following operative criteria: ≥20 mm medial/lateral (M/L) displacement (lateral border offset), ≥45° of angular deformity on a scapular-Y X-ray, the combination of angulation ≥30° plus M/L displacement ≥15 mm, double disruptions of the superior shoulder suspensory complex both displaced ≥10 mm, glenopolar angle (GPA) ≤22° and open fractures. Eighty-eight percent (74/84) had sufficient follow-up defined as at least 6 months. Measured outcomes included rates of scapula union and malunion, as well as surgical complications and re-operations. All fractures were caused by high-energy trauma with 24 (29%) resulting from motor-vehicle collisions. Associated injuries occurred in 94% of patients, most commonly involving the chest (70%) and ipsilateral shoulder girdle (43%). Forty-eight patients had M/L displacement as an operative indication with a mean displacement of 25.7 mm (range=20-40). Thirty-eight (45%) had ≥2 operative indications. A single surgeon performed ORIF in all patients using a posterior approach. Five patients also required an anterior (deltopectoral) approach. The fixation strategy included lateral and vertebral border stabilisation with dynamic compression and reconstruction plates, respectively. Union was achieved in all cases. There were three cases of malunion based on a GPA difference >10° from the uninjured shoulder. Re-operations included removal of hardware (seven patients) and manipulation under anaesthesia (three patients). There were no infections or wound dehiscence. ORIF for displaced scapula fractures is a relatively safe and effective procedure for restoration of anatomy and promotion of union. Therapeutic study, level IV. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. 10 CFR 960.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... which there is recurrent movement, which is usually indicated by small, periodic displacements or... of fluids, expressed as the ratio of the volume of interconnected pores and openings to the volume of... displacement of the side relative to one another parallel to the fracture or zone of fractures. Faulting means...

  5. 10 CFR 960.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... which there is recurrent movement, which is usually indicated by small, periodic displacements or... of fluids, expressed as the ratio of the volume of interconnected pores and openings to the volume of... displacement of the side relative to one another parallel to the fracture or zone of fractures. Faulting means...

  6. 10 CFR 960.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... which there is recurrent movement, which is usually indicated by small, periodic displacements or... of fluids, expressed as the ratio of the volume of interconnected pores and openings to the volume of... displacement of the side relative to one another parallel to the fracture or zone of fractures. Faulting means...

  7. 10 CFR 960.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... which there is recurrent movement, which is usually indicated by small, periodic displacements or... of fluids, expressed as the ratio of the volume of interconnected pores and openings to the volume of... displacement of the side relative to one another parallel to the fracture or zone of fractures. Faulting means...

  8. Facial nerve injuries associated with the retromandibular transparotid approach for reduction and fixation of mandibular condyle fractures.

    PubMed

    Shi, Dan; Patil, Pavan Manohar; Gupta, Ritika

    2015-04-01

    To document facial nerve (FN) injuries after surgical treatment of mandibular condylar fractures using the retromandibular transparotid approach and to identify risk factors associated with these injuries. A retrospective study of patients surgically treated for mandibular condylar fractures using the retromandibular transparotid approach over seven years was conducted. The primary study variable was the postoperative change in FN function after fracture fixation. Risk factors were categorized as demographic, anatomic, experience of the operator, fracture displacement/dislocation and number of miniplates placed at the fracture site. Appropriate statistics were computed. Ninety patients with 102 fractures were analysed. Thirty two fractures (31%) were located in the condylar neck and 70 fractures (69%) were subcondylar (located below the sigmoid notch). The condylar segment was undisplaced in twelve cases (12%), displaced medially in thirty five (34%), laterally displaced in thirty (29%) and dislocated in 25 (24.5%). In 18 fractures (18%), postoperative examination revealed various degrees of damage to the FN. All nerve injuries recovered completely in 8-24 weeks. In a multivariate model, condylar neck fractures, fracture dislocation and operator inexperience were associated with a statistically significant risk of postoperative deterioration of FN function (P ≤ 0.05). The majority of facial nerve injuries after surgical treatment of condylar fractures by the retromandibular transparotid approach are transient in nature. Condylar neck fractures, fracture dislocation and operator inexperience were associated with an increased risk for FN injury. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Suture Anchor Fixation for Fifth Metatarsal Tuberosity Avulsion Fractures: A Case Series and Review of Literature.

    PubMed

    Hong, Choon Chiet; Nag, Kushal; Yeow, Huifen; Lin, Adrian Zhigao; Tan, Ken Jin

    2018-05-17

    Fifth metatarsal tuberosity avulsion fractures are common. Despite good outcomes with nonoperative treatment, acute fractures with displacement, intra-articular involvement, comminution, or painful nonunion have been reported to benefit from early open reduction and internal fixation, especially in athletes. No consensus has been reached regarding the best surgical fixation technique. We present a case series of 4 patients with displaced fifth metatarsal tuberosity avulsion fractures and an innovative technique of fixation for the tuberosity avulsion fractures using a suture anchor. Copyright © 2018 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Pelvic crescent fractures: variations in injury mechanism and radiographic pattern.

    PubMed

    Gehlert, Rick J; Xing, Zhiqing; DeCoster, Thomas A

    2014-01-01

    Pelvic crescent fracture, also known as sacroiliac fracture-dislocation, is traditionally considered as a lateral compression injury and a vertically stable injury. Thirty consecutive cases were analyzed and it was found that 63% of cases were caused by lateral compression (LC), 27% by anteroposterior compression (APC), and 10% by vertical shear (VS). APC and VS injuries cause significant displacement of the anterior iliac fragment, but 21% of LC injury cases showed minimal displacement and were treated successfully with nonoperative treatment. Different injury mechanisms also produce different types of pelvic instability. More important, different injury mechanisms produce distinct radiographic fracture patterns regarding the obliquity of the fracture line and fracture surface. These differences in the fracture pattern will influence the decision of internal fixation options. Therefore, treatment of pelvic crescent fractures should be based on individual analysis of injury mechanism and radiographic fracture pattern.

  11. Outcome of nonoperative management of displaced oblique spiral fractures of the fifth metatarsal shaft.

    PubMed

    Aynardi, Michael; Pedowitz, David I; Saffel, Heather; Piper, Christine; Raikin, Steven M

    2013-12-01

    Nonoperative management has been the preferred treatment for displaced oblique spiral fractures of the fifth metatarsal shaft; yet a paucity of literature supports this claim. The purpose of this investigation was to report the incidence and long-term outcome in the largest cohort of these fractures reported to date. From 2006 through 2010, 2990 patients sustaining closed metatarsal fractures were seen and treated. Displaced, oblique, spiral fractures of the distal shaft of the fifth metatarsal were identified and follow-up was conducted. Only patients who were initially treated with nonoperative management were included. Patients were seen at 6 and 12 weeks, and a minimum 2-year follow-up was conducted. In addition, demographic information was obtained, and the Short Form-12 (SF-12) and Foot and Ankle Ability Measure (FAAM) were administered. Average follow-up was 3.5 years. In all, 142 acute fractures were managed for an incidence of 4.8% of all metatarsal fractures. There were 117 females and 25 males, average age was 55. FAAM activities of daily living subscale scores averaged 95.5 (±5.7), while FAAM sports subscales were 92.7 (±9.1). SF-12 physical and mental scores averaged 51.4 (±4.9) and 50.3 (±4.6), respectively. There were 2 delayed unions, 1 asymptomatic nonunion treated nonoperatively, and 2 painful nonunions that required open reduction internal fixation with bone grafting. This large cohort described the relative incidence and functional outcomes of displaced oblique fracture of shaft of the fifth metatarsal bone treated nonoperatively. Nonoperative management of these fractures resulted in excellent, long-term functional outcomes. Level II, prospective cohort study.

  12. The operative outcomes of displaced medial-end clavicle fractures.

    PubMed

    Sidhu, Verinder S; Hermans, Deborah; Duckworth, David G

    2015-11-01

    Nonoperative treatment of displaced medial clavicle fractures often leads to poor functional outcomes and painful nonunions. This study investigates the functional outcomes of patients undergoing operative fixation of these fractures. We investigated 27 patients undergoing operative fixation of a medial clavicle fracture; 24 had an acute, displaced fracture and 3 had fixation for nonunions. Preoperative radiographs or computed tomography scans were obtained, and data collected included age, sex, mechanism of injury, and fixation method. Follow-up included physical examination and radiographs for assessment of union; Disabilities of the Arm, Shoulder, and Hand scores at 12 months; and the recording of complications. The median age was 37 years (interquartile range, 17-47 years). There were 26 male patients and one female patient included, with 7 physeal injuries and 20 adult injuries. The most common mechanism of fracture was vehicular accident (n = 15). Three patients had operations for nonunions and 2 for a periprosthetic fracture medial to an existing plate. The fracture was fixed with plate and screws in 19 cases and with transosseous sutures in 8 cases. The median Disabilities of the Arm, Shoulder, and Hand score at 12 months was 0.4 (interquartile range, 0-5.0), with a union rate of 100% at 12 months. All patients had full shoulder range of motion at final follow-up and were able to return to preinjury occupational activities. There were no significant complications. Operative fixation of displaced medial clavicle fractures results in anatomic reconstruction and excellent functional outcomes, even in the setting of fixation performed for symptomatic nonunion. Early intervention can minimize the risk of painful nonunion. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  13. Transoral open reduction and fixation of mandibular condylar base and neck fractures in children and young teenagers--a beneficial treatment option?

    PubMed

    Schiel, Sebastian; Mayer, Peter; Probst, Florian; Otto, Sven; Cornelius, Carl-Peter

    2013-07-01

    To evaluate the possible benefits of open surgery, endoscopically assisted reduction and fixation using a transoral route was used in a selected series of pediatric patients with displaced condylar base and neck fractures. A cohort of 6 patients (1 male and 5 female; age range, 7 to 15 yr; mean, 13.4 yr) with displaced condylar base and neck fractures (n = 9) were included. Inclusion criteria were age younger than 16 years, fracture of the condylar base or neck, and displacement of the fracture by at least 45°. Fractures were classified using conventional radiography, cone-beam computed tomography, or computed tomography. Patients underwent transoral endoscopically assisted open reduction and fixation using miniplate osteosynthesis. Postoperatively, patients were followed clinically and radiographically for 18 months. Complete follow-up varied from 18 to 35 months (median, 24.5 months). All patients showed normal occlusion and pain-free unrestricted function of the temporomandibular joint at 3, 6, 12, and 18 months postoperatively. There were no signs of incomplete remodeling or deformation of the condyles. Transoral endoscopically assisted surgical treatment of severely displaced condylar base and neck fractures in children and young teenagers offers a reliable solution to preclude the sequelae of closed treatment, such as altered morphology and functional disturbances, eliminates visible scars, and lowers the risk of facial nerve damage compared with open reduction using an extraoral approach. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  14. A case report of a completely displaced stress fracture of the femoral shaft in a middle-aged male athlete - A precursor of things to come?

    PubMed

    Larsen, Peter; Elsoe, Rasmus; Rathleff, Michael S

    2016-05-01

    Displaced stress fractures of the femoral shaft are very uncommon. The proportion of middle-aged and older age groups participating in long-distance running, triathlon and other high intensity sports is increasing. As a consequence stress fracture of the femoral shaft may be on the rise in the future. The patient was 43 years old male caucasian triathlete. The authors met the patient after he was admitted with a displaced femoral shaft fracture. The fracture occurred during running at the national championship in ½ Ironman. The patient reported that his symptoms had gradually developed over the last month before the fracture with pain localized anterior to the thigh. The patient interpreted the symptoms as local muscle damage. A clinical examination was conducted by a physiotherapist and the symptoms were interpreted as a simple muscle injury in the quadriceps. When presented with a patient with non-traumatic, diffuse anterior thigh pain in an individual of this age, who is participating in high-level endurance running; clinicians should consider the possibility that the cause of the symptoms may be a femoral shaft stress fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Radiological and Functional Outcome of Displaced Colles’ Fracture Managed with Closed Reduction and Percutaneous Pinning: A Prospective Study

    PubMed Central

    Khatri, Kishor; Kharel, Krishna; Byanjankar, Subin; Sharma, Jay R; Shrestha, Rahul; Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2017-01-01

    Background: Displaced Colles’ fractures are treated by manipulation and below elbow cast application. Malunion is a common complication, resulting in pain, mid-carpal instability, and post-traumatic arthritis. Fracture stabilization by percutaneous pinning is a simple, minimally invasive technique that helps prevent displacement of the fracture, thereby minimizing complications. This study aims to assess the amount of collapse after closed manipulation and percutaneous pinning with Kirschner wires (K-wires) and its correlation with the functional outcome of the wrist after union. Methods: A prospective study was conducted from May 2015 to May 2016 in a tertiary orthopedic center. Ninety patients (60 females, 30 males) with an average age of 54.93 years with Type II fractures underwent closed manipulation and percutaneous pinning with crossed K-wires as the primary procedure. Serial radiographs were taken to document the amount of collapse. The functional outcome was assessed using the Cooney Wrist Score. Results: At the final follow-up at six months, the collapse in the mean dorsal angle was 0.94 and mean ulnar variance was 0.51. Functionally, 48 patients (53.33%) had an excellent outcome, 36 patients (40%) had a good outcome, and six patients (6.67%) had a fair outcome. Conclusions: Displaced Colles’ fractures should be reduced and stabilized with percutaneous K-wires to achieve an excellent functional outcome. PMID:28191366

  16. Radiological and Functional Outcome of Displaced Colles' Fracture Managed with Closed Reduction and Percutaneous Pinning: A Prospective Study.

    PubMed

    Panthi, Sagar; Khatri, Kishor; Kharel, Krishna; Byanjankar, Subin; Sharma, Jay R; Shrestha, Rahul; Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2017-01-06

    Displaced Colles' fractures are treated by manipulation and below elbow cast application. Malunion is a common complication, resulting in pain, mid-carpal instability, and post-traumatic arthritis. Fracture stabilization by percutaneous pinning is a simple, minimally invasive technique that helps prevent displacement of the fracture, thereby minimizing complications. This study aims to assess the amount of collapse after closed manipulation and percutaneous pinning with Kirschner wires (K-wires) and its correlation with the functional outcome of the wrist after union. A prospective study was conducted from May 2015 to May 2016 in a tertiary orthopedic center. Ninety patients (60 females, 30 males) with an average age of 54.93 years with Type II fractures underwent closed manipulation and percutaneous pinning with crossed K-wires as the primary procedure. Serial radiographs were taken to document the amount of collapse. The functional outcome was assessed using the Cooney Wrist Score. At the final follow-up at six months, the collapse in the mean dorsal angle was 0.94 and mean ulnar variance was 0.51. Functionally, 48 patients (53.33%) had an excellent outcome, 36 patients (40%) had a good outcome, and six patients (6.67%) had a fair outcome. Displaced Colles' fractures should be reduced and stabilized with percutaneous K-wires to achieve an excellent functional outcome.

  17. Asynchronous cracking with dissimilar paths in multilayer graphene.

    PubMed

    Jang, Bongkyun; Kim, Byungwoon; Kim, Jae-Hyun; Lee, Hak-Joo; Sumigawa, Takashi; Kitamura, Takayuki

    2017-11-16

    Multilayer graphene consists of a stack of single-atomic-thick monolayer graphene sheets bound with π-π interactions and is a fascinating model material opening up a new field of fracture mechanics. In this study, fracture behavior of single-crystalline multilayer graphene was investigated using an in situ mode I fracture test under a scanning electron microscope, and abnormal crack propagation in multilayer graphene was identified for the first time. The fracture toughness of graphene was determined from the measured load-displacement curves and the realistic finite element modelling of specimen geometries. Nonlinear fracture behavior of the multilayer graphene is discussed based on nonlinear elastic fracture mechanics. In situ scanning electron microscope images obtained during the fracture test showed asynchronous crack propagation along independent paths, causing interlayer shear stress and slippages. We also found that energy dissipation by interlayer slippages between the graphene layers is the reason for the enhanced fracture toughness of multilayer graphene. The asynchronous cracking with independent paths is a unique cracking and toughening mechanism for single-crystalline multilayer graphene, which is not observed for the monolayer graphene. This could provide a useful insight for the design and development of graphene-based composite materials for structural applications.

  18. Haematoma block in reduction of distal radial fractures.

    PubMed

    Ogunlade, S O; Omololu, A B; Alonge, T O; Salawu, S A; Bamgboye, E A

    2002-01-01

    A total of 35 patients who presented in the Accident and Emergency Department of University College Hospital with displaced distal radial fracture between January 2000 and March 2001 had reduction of the fracture under haematoma block using 10ml of 2% lignocaine. There was significant reduction of the pain following infiltration of the fracture site with lignocaine and significant pain reduction during manipulation compared to pain score at presentation. All the patients had satisfactory reduction of the fracture. The fracture was mobilised in Plaster of Paris 6 weeks in patients with Collens' fracture and 3 weeks in patients with distal radial epiphyseal injury. All patients had good range of movement at 8 weeks after removal of Plaster of Paris and patients expressed satisfaction with this method. We recommend the use of Haematoma block for patients of 15 years and above with displaced distal radial fracture in the Accident and Emergency Department.

  19. Fractures of the Talus: State of the Art.

    PubMed

    Vallier, Heather A

    2015-09-01

    Talus fractures occur rarely but are often associated with complications and functional limitations. Urgent reduction of associated dislocations is recommended with open reduction and internal fixation of displaced fractures when adjacent soft tissue injury permits. Delayed definitive fixation may reduce the risks of wound complications and infections. Restoration of articular and axial alignment is necessary to optimize ankle and hindfoot function. Despite this, posttraumatic arthrosis occurs frequently after talar neck and body fractures, especially with comminution of the talar body. Osteonecrosis is reported in up to half of talar neck fractures, although many of these injuries will revascularize without collapse of the talar dome. Initial fracture displacement and presence of open fractures increase the risk of osteonecrosis. Talar process fractures may be subtle and easily missed on plain radiographs. Advanced imaging will provide detail to facilitate treatment planning. Therapeutic Level V. See Instructions for Authors for a complete description of levels of evidence.

  20. Locked nailing for the treatment of displaced articular fractures of the calcaneus: description of a new procedure with calcanail(®).

    PubMed

    Goldzak, Mario; Mittlmeier, Thomas; Simon, Patrick

    2012-05-01

    Although open reduction and internal fixation is considered the best method for treating displaced articular fractures of the calcaneus, lateral approach is at high risk for wound healing complications. For this reason, the authors developed a posterior approach and a new implant to perform both intrafocal reduction and internal fixation. The aim of this technical note is to describe this method of treatment for displaced articular fractures of the calcaneus, which offered the following advantages: (a) the creation of a working channel that provides also a significant bone autograft, (b) the intrafocal reduction of the displaced articular surface, (c) the insertion of a locking nail that maintains the reduced articular surface at the right height, (d) the possibility to switch from an ORIF to a reconstruction arthrodesis with the same approach and instrumentation in case of severely damaged posterior facet.

  1. Three-dimensional fracture instability of a displacement-weakening planar interface under locally peaked nonuniform loading

    NASA Astrophysics Data System (ADS)

    Uenishi, Koji

    2018-06-01

    We consider stability of fracture on a three-dimensional planar interface subjected to a loading stress that is locally peaked spatially, the level of which increases quasi-statically in time. Similar to the earlier study on the two-dimensional case (Uenishi and Rice, 2003; Rice and Uenishi, 2010), as the loading stress increases, a crack, or a region of displacement discontinuity (opening gap in tension or slip for shear fracture), develops on the interface where the stress is presumed to decrease according to a displacement-weakening constitutive relation. Upon reaching the instability point at which no further quasi-static solution for the extension of the crack on the interface exists, dynamic fracture follows. For the investigation of this instability point, we employ a dimensional analysis as well as an energy approach that gives a Rayleigh-Ritz approximation for the dependence of crack size and maximum displacement discontinuity on the level and quadratic shape of the loading stress distribution. We show that, if the linear displacement-weakening law is applied and the crack may be assumed of an elliptical form, the critical crack size at instability is independent of the curvature of the loading stress distribution and it is of the same order for all two- and three-dimensional cases.

  2. Mode I Cohesive Law Characterization of Through-Crack Propagation in a Multidirectional Laminate

    NASA Technical Reports Server (NTRS)

    Bergan, Andrew C.; Davila, Carlos G.; Leone, Frank A.; Awerbuch, Jonathan; Tan, Tein-Min

    2014-01-01

    A method is proposed and assessed for the experimental characterization of through-the-thickness crack propagation in multidirectional composite laminates with a cohesive law. The fracture toughness and crack opening displacement are measured and used to determine a cohesive law. Two methods of computing fracture toughness are assessed and compared. While previously proposed cohesive characterizations based on the R-curve exhibit size effects, the proposed approach results in a cohesive law that is a material property. The compact tension specimen configuration is used to propagate damage while load and full-field displacements are recorded. These measurements are used to compute the fracture toughness and crack opening displacement from which the cohesive law is characterized. The experimental results show that a steady-state fracture toughness is not reached. However, the proposed method extrapolates to steady-state and is demonstrated capable of predicting the structural behavior of geometrically-scaled specimens.

  3. [Intramedullary stabilisation of displaced midshaft clavicular fractures: does the fracture pattern (simple vs. complex) influence the anatomic and functional result].

    PubMed

    Langenhan, R; Reimers, N; Probst, A

    2014-12-01

    Displaced midshaft clavicular fractures are often treated operatively. The most common way of treatment is plating. Elastic stable intramedullary nailing (ESIN) is an alternative, but seldom used. Studies showed comparable or even better results for intramedullary nailing than for plating in simple 2- or 3-fragment midshaft fractures. The indication of ESIN for multifragmentary clavicular fractures is discussed critically in the literature because of reduced primary stability and danger of secondary shortening. Until now only few studies report functional results after fracture healing depending on the fracture type. To the best of our knowledge there is no study showing significantly worse functional scores for ESIN in complex displaced midshaft fractures. The objective of this study was to examine anatomic and functional results of simple (2 or 3 fragments, OTA type 15B1 and 15B2) and complex (multifragmentary, OTA type 15B3) displaced midshaft clavicula fractures after internal fixation. Between 2009 and 2012, 40 patients (female/male 10/30; mean age 33 [16-60] years) with closed displaced midshaft clavicular fractures were treated by open reduction and ESIN (Titanium Elastic Nail [TEN], Synthes, Umkirch, Germany). Thirty-seven patients were retrospectively analysed after a mean of 27 (12-43) months. Twenty patients (group A) had simple fractures (OTA type 15B1 and 15B2), 17 patients (group B) had complex fractures (OTA type 15B3). All shoulder joints were postoperatively treated functionally for six weeks without weight limited to 90° abduction/flexion. Both groups were comparable in gender, age, body mass index, months until metal removal, number of physiotherapy sessions and time until follow-up examination. Joint function (neutral zero method) and strength (standing patient with arm in 90° abduction, holding 1-12 kg for 5 sec) in both shoulders were documented. The distance between the centre of the jugulum and the lateral acromial border was measured for both sides. The DASH, Constant-Murley, Oxford shoulder and clavicular scores (Jubel) were calculated. Patients documented contentedness of outcome by VAS between 0 (absolute discontented) and 10 (very contented). Complications were recorded. Operatively treated displaced midshaft clavicular fractures. in comparison to the healthy side in group A had an average shortening of 5 (0-20) mm and in group B of 10 (3-25) mm, with a statistical significance between both groups. Patients of both groups were very contented with the results (VAS group A: 9.6; B: 9.5). DASH score (group A: 28; B: 3.1), Constant-Murley score (group A: 95.0; B: 93.8), Oxford shoulder score (group A: 46.2; B: 45.9) and the clavicula score (Jubel) (group A: 1.2; B: 2.1) were comparable between both groups without significance. In 4 patients (11%) complications occurred. Once (group B) an infection was seen, three times (group B) the ESIN had to be shortened on the medial side because of telescoping. Open ESIN of simple and complex displaced midshaft clavicular fractures leads after an average of 27 months to good or even excellent results. Healing of the clavicle in a modestly shortened position does not impair the patient. Georg Thieme Verlag KG Stuttgart · New York.

  4. Proximal Humerus Fractures: Evaluation and Management in the Elderly Patient

    PubMed Central

    Grawe, Brian

    2018-01-01

    Introduction: Proximal humerus fractures are common in the elderly. The evaluation and management of these injuries is often controversial. The purpose of this study is to review recent evidence and provide updated recommendations for treating proximal humerus fractures in the elderly. Methods: A literature review of peer-reviewed publications related to the evaluation and management of proximal humerus fractures in the elderly was performed. There was a focus on randomized controlled trials and systematic reviews published within the last 5 years. Results: The incidence of proximal humerus fractures is increasing. It is a common osteoporotic fracture. Bone density is a predictor of reduction quality and can be readily assessed with anteroposterior views of the shoulder. Social independence is a predictor of outcome, whereas age is not. Many fractures are minimally displaced and respond acceptably to nonoperative management. Displaced and severe fractures are most frequently treated operatively with intramedullary nails, locking plates, percutaneous techniques, or arthroplasty. Discussion: Evidence from randomized controlled trials and systematic reviews is insufficient to recommend a treatment; however, most techniques have acceptable or good outcomes. Evaluation should include an assessment of the patient’s bone quality, social independence, and surgical risk factors. With internal fixation, special attention should be paid to medial comminution, varus angulation, and restoration of the calcar. With arthroplasty, attention should be paid to anatomic restoration of the tuberosities and proper placement of the prosthesis. Conclusion: A majority of minimally displaced fractures can be treated conservatively with early physical therapy. Treatment for displaced fractures should consider the patient’s level of independence, bone quality, and surgical risk factors. Fixation with percutaneous techniques, intramedullary nails, locking plates, and arthroplasty are all acceptable treatment options. There is no clear evidence-based treatment of choice, and the surgeon should consider their comfort level with various procedures during the decision-making process. PMID:29399372

  5. Closed Versus Open Supracondylar Fractures of the Humerus in Children: A Comparison of Clinical and Radiographic Presentation and Results.

    PubMed

    Lewine, Eliza; Kim, Jaehon M; Miller, Patricia E; Waters, Peter M; Mahan, Susan T; Snyder, Brian; Hedequist, Daniel; Bae, Donald S

    2018-02-01

    The purpose of this investigation was to compare the presentation and postoperative results of children treated for open and closed, completely displaced type III supracondylar humerus fractures (SCFs). Thirty patients with open and 66 patients with closed, completely displaced type III SCFs were evaluated. Open fractures underwent irrigation and debridement, and all patients were treated by open or closed reduction and pin fixation. Medical records were reviewed to obtain demographic information as well as preoperative and postoperative clinical data regarding mechanism of injury, neurovascular status, associated injuries, postoperative range of motion, infections, and pain. Radiographs were evaluated to quantify displacement, Baumann's angle, humeral capitellar angle, position of the anterior humeral line, and adequacy of reduction. Outcomes were assessed using Flynn criteria. Mean clinical follow-up for the open and closed fracture groups was 8.9 and 5.7 months, respectively. Both groups were similar with respect to age, sex distribution, weight and body mass index, laterality of involvement, and mechanism of injury. At presentation, 35% of closed SCFs and 23% of open SCFs presented with abnormal neurovascular status. There was a higher prevalence of diminished/absent pulses or distal limb ischemia in patients with open injuries (27%) compared with closed fractures (18%). Conversely, severely displaced closed fractures were more commonly associated with nerve injury/palsy at presentation (35%) than those with open fractures (23%). Spontaneous nerve recovery was seen in 87% within 3 to 6 months. Postoperative loss of reduction and malunion were more common in the closed fracture group. However, 84% of patients achieved good-to-excellent results by Flynn criteria, with no appreciable difference based upon open versus closed fractures. With timely wound and fracture treatment, the clinical and radiographic results of children treated for open SCFs is similar to those with closed type III injuries, with little increased risk for infection, malunion, or neurovascular compromise. Level III.

  6. Variation Among Pediatric Orthopaedic Surgeons When Treating Medial Epicondyle Fractures.

    PubMed

    Hughes, Meghan; Dua, Karan; O'Hara, Nathan N; Brighton, Brian K; Ganley, Theodore J; Hennrikus, William L; Herman, Martin J; Hyman, Joshua E; Lawrence, J Todd; Mehlman, Charles T; Noonan, Kenneth J; Otsuka, Norman Y; Schwend, Richard M; Shrader, M Wade; Smith, Brian G; Sponseller, Paul D; Abzug, Joshua M

    2017-10-18

    Medial epicondyle fractures are a common pediatric and adolescent injury accounting for 11% to 20% of elbow fractures in this population. This purpose of this study was to determine the variability among pediatric orthopaedic surgeons when treating pediatric medial epicondyle fractures. A discrete choice experiment was conducted to determine which patient and injury attributes influence the management of medial epicondyle fractures by pediatric orthopaedic surgeons. A convenience sample of 13 pediatric orthopaedic surgeons reviewed 60 case vignettes of medial epicondyle fractures that included elbow radiographs and patient/injury characteristics. Displacement was incorporated into the study model as a fixed effect. Surgeons were queried if they would treat the injury with immobilization alone or open reduction and internal fixation (ORIF). Statistical analysis was performed using a mixed effect regression model. In addition, surgeons filled out a demographic questionnaire and a risk assessment to determine if these factors affected clinical decision-making. Elbow dislocation and fracture displacement were the only attributes that significantly influenced surgeons to perform surgery (P<0.05). The presence of an elbow dislocation had the largest impact on surgeons when choosing operative care (β=-0.14; P=0.02). In addition, for every 1 mm increase in displacement, surgeons tended to favor ORIF by a factor of 0.09 (P<0.01). Sex, mechanism of injury, and sport participation did not influence decision-making. In total, 54% of the surgeons demonstrated a preference for ORIF for the included scenarios. On the basis of the personality Likert scale, participants were neither high-risk takers nor extremely risk adverse with an average-risk score of 2.24. Participant demographics did not influence decision-making. There is substantial variation among pediatric orthopaedic surgeons when treating medial epicondyle fractures. The decision to operate is significantly based on the degree of fracture displacement and if there is a concomitant elbow dislocation. There is no standardization regarding how to treat medial epicondyle fractures and better treatment algorithms are needed to provide better patient outcomes. Level V.

  7. A further study on seismic response of a set of parallel rock fractures filled with viscoelastic materials

    NASA Astrophysics Data System (ADS)

    Wu, W.; Zhu, J. B.; Zhao, J.

    2013-02-01

    The purpose of this study is to further investigate the seismic response of a set of parallel rock fractures filled with viscoelastic materials, following the work by Zhu et al. Dry quartz sands are used to represent the viscoelastic materials. The split Hopkinson rock bar (SHRB) technique is modified to simulate 1-D P-wave propagation across the sand-filled parallel fractures. At first, the displacement and stress discontinuity model (DSDM) describes the seismic response of a sand-filled single fracture. The modified recursive method (MRM) then predicts the seismic response of the sand-filled parallel fractures. The SHRB tests verify the theoretical predictions by DSDM for the sand-filled single fracture and by MRM for the sand-filled parallel fractures. The filling sands cause stress discontinuity across the fractures and promote displacement discontinuity. The wave transmission coefficient for the sand-filled parallel fractures depends on wave superposition between the fractures, which is similar to the effect of fracture spacing on the wave transmission coefficient for the non-filled parallel fractures.

  8. Biomechanical comparison of fixation methods in transverse patella fractures.

    PubMed

    Scilaris, T A; Grantham, J L; Prayson, M J; Marshall, M P; Hamilton, J J; Williams, J L

    1998-01-01

    To compare monofilament wire versus braided cable for stabilizing transverse patella fractures using the modified AO tension band technique. A randomized blocked (paired) study comparing two fixation methods. Statistical analysis was performed using a nested repeated measures analysis, followed by Bonferroni post hoc testing. Seven paired embalmed knees (mean age 71.8 years, SD 14.6 years) were dissected, and transverse fractures were simulated. The knees were reduced and randomly fixed by either two parallel 0.062-inch Kirschner wires with a 1.0-millimeter-diameter 316L stainless steel monofilament wire tension loop or two Kirschner wires with a 1.0-millimeter-diameter 316L stainless steel braided cable tension loop. Knees were tested by applying a cyclic load through the suprapatellar tendon between twenty and 300 newtons for thirty cycles. The maximum fracture displacement increased with each cycle of loading for both the braided cable and monofilament wire tension loop configurations (p = 0.0001). The average peak displacement at the thirtieth cycle was 2.25 millimeters for monofilament wire and 0.73 millimeters for the cable. When comparing both methods for all cycles, the braided cable allowed less fracture displacement than did the monofilament wire (p = 0.002), and the rate of increase per cycle of maximum fracture displacement was less for the cable than for the wire (p = 0.0001). In transverse, noncomminuted patella fractures, fixation with two Kirschner wires and a 1.0-millimeter braided cable tension loop was superior to the monofilament wire tension loop. Most importantly, the braided cable afforded more predictable results during cyclic loading.

  9. A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model.

    PubMed

    Alluri, Ram K; Bougioukli, Sofia; Stevanovic, Milan; Ghiassi, Alidad

    2017-09-01

    To compare the biomechanical properties of second versus third metacarpal distal fixation when using a radiocarpal spanning distraction plate in an unstable distal radius fracture model. Biomechanical evaluation of the radiocarpal spanning distraction plate comparing second versus third metacarpal distal fixation was performed using a standardized model of an unstable wrist fracture in 10 matched-pair cadaveric specimens. Each fixation construct underwent a controlled cyclic loading protocol in flexion and extension. The resultant displacement and stiffness were calculated at the fracture site. After cyclic loading, each specimen was loaded to failure. The stiffness, maximum displacement, and load to failure were compared between the 2 groups. Cyclic loading in flexion demonstrated that distal fixation to the third metacarpal resulted in greater stiffness compared with the second metacarpal. There was no significant difference between the 2 groups with regards to maximum displacement at the fracture site in flexion. Cyclic loading in extension demonstrated no significant difference in stiffness or maximum displacement between the 2 groups. The average load to failure was similar for both groups. Fixation to the third metacarpal resulted in greater stiffness in flexion. All other biomechanical parameters were similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a spanning internal distraction plate. The treating surgeon should choose distal metacarpal fixation primarily based on fracture pattern, alignment, and soft tissue integrity. If a stiffer construct is desired, placement of the radiocarpal spanning plate at the third metacarpal is preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. A Biomechanical Study of Posteromedial Tibial Plateau Fracture Stability: Do They All Require Fixation?

    PubMed

    Cuéllar, Vanessa G; Martinez, Danny; Immerman, Igor; Oh, Cheongeun; Walker, Peter S; Egol, Kenneth A

    2015-07-01

    Although the posteromedial fragment in tibial plateau fractures is often considered unstable, biomechanical evidence supporting this view is lacking. We aimed to evaluate the stability of the fragment in a cadaver model. Our hypothesis was that under the expected small axial force during rehabilitation and the combined effects of this force with shear force, internal rotation torque, and varus moment, the most common posteromedial tibial fragment morphology could maintain stability in early flexion. Axial compression force alone or combined with posterior shear, internal rotation torque, or varus moment was applied to the femurs of 5 fresh cadaveric knees. A Tekscan pressure mapping system was used to measure pressure and contact area between the femoral condyles, meniscus, and tibial plateau. A Microscribe 3D digitizer was used to define the 3-dimensional positions of the femur and tibia. A 10-mm and then a 20-mm osteotomy was created with a saw at an angle of 30 degrees in the axial plane with respect to the tangent of the posterior tibial plateau and 75 degrees in the sagittal plane, representing a typical posteromedial fracture fragment. At each flexion angle (15, 30, 60, 90, and 120 degrees) and loading condition (axial compression only, compression with shear force, torque, and varus moment), distal displacement of the medial femoral condyle and the tibial fracture fragments was determined. For the 10-mm fragment, medial femoral condyle displacement was little affected up to approximately 30-degree flexion, after which it increased. For the 20-mm fragment, there was progressive medial femoral condyle displacement with increasing flexion from baseline. However, for the 10- and 20-mm fragments themselves, displacements were noted at every flexion angle, starting at 1.7 mm inferior displacement with 15 degrees of flexion and internal rotation torque and up to 10.2 mm displacement with 90 degrees of flexion and varus bending moment. In this cadaveric model of a posteromedial tibial plateau fracture, both fracture fragments studied displaced with knee flexion, even at low flexion angles. Although such fragments may initially seem nondisplaced after injury, posteromedial fragments similar to these tested are likely to displace during knee range of motion exercises in non-weight-bearing conditions.

  11. Mandibular fracture patterns consistent with posterior maxillary fractures involving the posterior maxillary sinus, pterygoid plate or both: CT characteristics.

    PubMed

    Imai, T; Sukegawa, S; Kanno, T; Fujita, G; Yamamoto, N; Furuki, Y; Michizawa, M

    2014-01-01

    The aim of this study was to determine the incidence of posterior maxillary fractures involving the posterior maxillary sinus wall, pterygoid plate or both, unrelated to major midface fractures in patients with mandibular fractures, and to characterize associated fractures. A CT study was performed in patients with mandibular fractures to identify posterior maxillary fractures. Patients aged under 16 years, those with mandibular fractures involving only dentoalveolar components and those with concurrent major midfacial fractures were excluded. 13 (6.7%) of 194 patients with mandibular fractures also had posterior maxillary fractures (case group). The injury pattern correlated with the external force directed to the lateral side of the mandible (p < 0.001), alcohol consumption (p = 0.049), the presence of multifocal fractures (p = 0.002) and the fracture regions in the symphysis/parasymphysis (p = 0.001) and the angle/ramus (p = 0.001). No significant difference between the case and non-case groups was seen for age, sex or cause of trauma. Non-displaced fractures in the ipsilateral posterior mandible occurred with significant frequency (p = 0.001) when the posterior maxillary fractures involved only the sinus. Mandibular fractures accompanied by posterior maxillary fractures are not rare. The finding of a unilateral posterior maxillary fracture on CT may aid the efficient radiological examination of the mandible based on possible patterns of associated fractures, as follows: in the ipsilateral posterior region as a direct fracture when the impact is a medially directed force, and in the symphysis/parasymphysis or contralateral condylar neck as an indirect fracture.

  12. Reliability of the Robinson classification for displaced comminuted midshaft clavicular fractures.

    PubMed

    Stegeman, Sylvia A; Fernandes, Nicole C; Krijnen, Pieta; Schipper, Inger B

    2015-01-01

    This study aimed to assess the reliability of the Robinson classification for displaced comminuted midshaft fractures. A total of 102 surgeons and 52 radiologists classified 15 displaced comminuted midshaft clavicular fractures on anteroposterior (AP) and 30-degree caudocephalad radiographs twice. For both surgeons and radiologists, inter-observer and intra-observer agreement significantly improved after showing the 30-degree caudocephalad view in addition to the AP view. Radiologists had significantly higher inter- and intra-observer agreement than surgeons after judging both radiographs (κmultirater of 0.81 vs. 0.56; κintra-observer of 0.73 vs. 0.44). We advise to use two-plane radiography and to routinely incorporate the Robinson classification in the radiology reports. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Complications in the Treatment of Adolescent Clavicle Fractures

    PubMed Central

    Luo, T. David; Ashraf, Ali; Larson, A. Noelle; Stans, Anthony A.; Shaughnessy, William J.; McIntosh, Amy L.

    2015-01-01

    The authors’ study evaluates the complications associated with the treatment of clavicle fractures in adolescents. During the study period, 153 clavicle fractures occurred in patients between the ages of 14 and 17 years who were treated at the authors’ center, of which 23 (15.0%) were treated surgically. Compared to the fractures treated nonoperatively, the surgical fractures had greater shortening (mean, 2.0 vs 0.9 cm; P<.001) and were more likely to be comminuted (65.2% vs 23.1%; P<.001). Complications occurred in 21.7% of fractures treated surgically. One delayed union occurred in the nonoperative cohort, but no other complications or patients who required clavicular osteotomy for malunion. Pediatric fellowship-trained orthopedic surgeons treated 78 displaced fractures, resulting in 8 (10.3%) surgeries. Nonpediatric orthopedic specialists treated 46 displaced fractures, 15 (32.6%) of which were treated operatively (P=.0035). FigureA 15-year-old boy sustained a comminuted clavicle fracture from playing football. Preoperative radiograph showing significant clavicle shortening and a vertical fragment. PMID:25901621

  14. Clavicle fractures: epidemiology, classification and treatment of 2 422 fractures in the Swedish Fracture Register; an observational study.

    PubMed

    Kihlström, Caroline; Möller, Michael; Lönn, Katarina; Wolf, Olof

    2017-02-15

    Large multi-centre studies of clavicle fractures have so far been missing. The aim of this observational study was to describe the epidemiology, classification and treatment of clavicle fractures in the The Swedish Fracture Register (SFR) that collects national prospective data from large fracture populations. Data were retrieved from the SFR on all clavicle fractures sustained by patients ≥ 15 years of age in 2013-2014 (n = 2 422) with regards to date of injury, cause of injury, fracture classification and treatment. Sixty-eight per cent of the clavicle fractures occurred in males. The largest subgroup was males aged 15-24 years, representing 21% of clavicle fractures. At the ages of 65 years and above, females sustained more clavicle fractures than males. Same-level falls and bicycle accidents were the most common injury mechanisms. Displaced midshaft fractures constituted 43% of all fractures and were the most frequently operated fractures. Seventeen per cent of the patients underwent operative treatment within 30 days of the injury, where plate fixation was the choice of treatment in 94% of fractures. The largest patient group was young males. Displaced midshaft fractures were the most common type of clavicle fracture as well as the most frequently operated type of fracture.

  15. [Incarcerated epitrochlear fracture with a cubital nerve injury].

    PubMed

    Moril-Peñalver, L; Pellicer-Garcia, V; Gutierrez-Carbonell, P

    2013-01-01

    Injuries of the medial epicondyle are relatively common, mostly affecting children between 7 and 15 years. The anatomical characteristics of this apophysis can make diagnosis difficult in minimally displaced fractures. In a small percentage of cases, the fractured fragment may occupy the retroepitrochlear groove. The presence of dysesthesias in the territory of the ulnar nerve requires urgent open reduction of the incarcerated fragment. A case of a seven-year-old male patient is presented, who required surgical revision due to a displaced medial epicondyle fracture associated with ulnar nerve injury. A review of the literature is also made. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  16. Patterns of triangular fibrocartilage complex (TFCC) injury associated with severely dorsally displaced extra-articular distal radius fractures.

    PubMed

    Scheer, Johan H; Adolfsson, Lars E

    2012-06-01

    The aim of the study was to examine triangular fibrocartilage (TFCC) injury patterns associated with unstable, extra-articular dorsally displaced distal radius fractures. Twenty adult patients with an Arbeitsgemeinschaft für Osteosynthesefragen (AO), type A2 or A3, distal radius fracture with an initial dorsal angulation greater than 20° were included. Nine had a tip fracture (distal to the base) of the ulnar styloid and 11 had no such fracture. They were all openly explored from an ulnopalmar approach and TFCC injuries were documented. Eleven patients also underwent arthroscopy and intra-articular pathology was recorded. All patients had TFCC lesions of varying severity, having an extensor carpi ulnaris subsheath avulsion in common. Eighteen out of 20 also displayed deep foveal radioulnar ligament lesions, with decreasingly dorsal fibres remaining. The extent of this foveal injury could not be appreciated by radiocarpal arthroscopy. Severe displacement of an extra-articular radius fracture suggests an ulnar-sided ligament injury to the TFCC. The observed lesions concur with findings in a previous cadaver study. The lesions follow a distinct pattern affecting both radioulnar as well as ulnocarpal stabilisers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Management of displaced comminuted patellar fracture with titanium cable cerclage.

    PubMed

    Yang, Li; Yueping, Ouyang; Wen, Yuan

    2010-08-01

    Management of a displaced comminuted patellar fracture is challenging. Tension band wiring and lag screw fixation are not suitable for such a fracture pattern. Stainless steel wiring with various configurations has been the mainstay of treatment. However, issues of loss of fixation and breakage of wire have not been resolved yet. Partial or total patellectomy is the last resort with a detrimental effect on quadriceps power. Braided titanium cable is stronger in tensile strength and better in fatigue resistance than the stainless steel monofilament wire, and the tension of fixation could be controlled by a graded instrument in its application. We used titanium cable to treat 21 consecutive patients with displaced comminuted patellar fracture. Patients were followed up for a mean period of 24 months (12 to 32 months). The mean score at the final follow-up was 27 points (25 to 30) using the Böstman method. There was no complication except breakage of one cable at the sixth week after the operation and the fracture had united despite the breakage. This technique is simple and effective for these difficult fractures and avoided prolonged immobilisation of the knee. Copyright 2010 Elsevier B.V. All rights reserved.

  18. Isolated displaced non-union of a triquetral body fracture: a case report.

    PubMed

    Rasoli, Sonia; Ricks, Matthew; Packer, Greg

    2012-02-10

    Fractures of the body of the triquetral bone are the second most common carpal fractures, and these fractures can be missed on plain X-ray. Although non-union of triquetral body fractures is very rare, such cases are associated with considerable morbidity and reduction in functional activity. We report the case of a 29-year-old Caucasian British man who sustained an isolated displaced triquetral body fracture that resulted in non-union, who was treated surgically. We describe an original operative management for this debilitating injury. An open reduction and internal fixation using double headed compression screws was performed, without bone grafting, and with early immobilization of the wrist. We propose this novel approach and advocate early clinical suspicion of triquetral body fractures in patients with a history of fall on an outstretched hand and ulnar sided wrist pain. We recommend evaluation using computed tomography or magnetic resonance imaging scanning.

  19. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    PubMed

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Intrinsic and extrinsic risk factors for nonunion after nonoperative treatment of midshaft clavicle fractures.

    PubMed

    Liu, W; Xiao, J; Ji, F; Xie, Y; Hao, Y

    2015-04-01

    The optimal treatment of midshaft clavicle fractures remains controversial. Nonunion is usually considered to be an uncommon complication following a nonoperatively treated clavicle fracture. Not every midshaft clavicular fractures shares the same risk of developing nonunion after nonoperative treatment. The present study was performed to identify the intrinsic and extrinsic independent factors that are independently predictive of nonunion in patients with midshaft clavicular fractures after nonoperative treatment. We performed a retrospective study of a series of 804 patients (391 men and 413 women with a median age of 51.3 years) with a radiographically confirmed midshaft clavicle fracture, which was treated nonoperatively. There were 96 patients who underwent nonunion. Putative intrinsic (patient-related) and extrinsic (injured-related) risk factors associated with nonunion were determined with the use of bivariate and multivariate statistical analyses. By bivariate analysis, the risk of nonunion was significantly increased by several intrinsic risk factors including age, sex, and smoking and extrinsic risk factors including displacement of the fracture and the presence of comminution (P<0.05 for all). On multivariate analysis, smoking (OR=4.16, 95% CI: 1.01-14.16), fracture displacement (OR=7.81, 95% CI: 2.27-25.38) and comminution of fracture (OR=3.86, 95% CI: 1.16-13.46) were identified as independent predictive factors. The risk factors for nonunion after nonoperative treatment of midshaft clavicle fractures are multifactorial. Smoking, fracture displacement and comminution of fracture are independent predictors for an individual likelihood of nonunion. Further studies are still required to evaluate these factors in the future. Level III, case-control study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. Revision rates and cumulative financial burden in patients treated with hemiarthroplasty compared to cannulated screws after femoral neck fractures.

    PubMed

    Shields, Edward; Kates, Stephen L

    2014-12-01

    This study compares re-operation rates and financial burden following the treatment of femoral neck fractures treated with hemiarthroplasty compared to non-displaced femoral neck fractures treated with cannulated screws. Data was retrospectively analyzed from a prospective database at a university hospital setting on patients undergoing hemiarthroplasty after femoral neck fractures and those with non-displaced femoral neck fractures treated with cannulated screws over a 7-year period. Re-operation rates were determined and financial data was analyzed. Charges refer to amounts billed by the hospital to insurance carriers, while costs refer to financial burden carried by the hospital during treatment. There were 491 femoral neck fractures (475 patients) that underwent hemiarthroplasty (HA) and 120 non-displaced fractures (119 patients) treated with cannulated screw (CannS) fixation. Both groups had similar age, sex, Charlson co-morbidity scores, pre-operative Parker mobility scores, and 12-month mortality. There were 29 (5.9 %) reoperations in the HA group and 16 (13.3 %) in the CannS group (P = 0.007). The majority of re-operations occurred within 12 months for both groups [21/29 (72 %) HA group; 15/16 (94 %) CannS group; P = 0.13]. Average hospital charges per patient for the index procedure were higher in the HA group ($17,880 ± 745) compared to the CannS group ($14,104 ± 5,047; P < 0.001). After accounting for additional procedures related to their initial surgical fixation, average hospital charges and costs remained higher in the HA group. Patients treated with hemiarthroplasty for femoral neck fractures have lower re-operation rates than patients treated with cannulated screws for non-displaced femoral neck fractures, with 80 % of re-operations occurring in the first 12 months. Hospital charges and costs to the hospital for treating patients undergoing hemiarthroplasty were higher than patients treated with cannulated screws for the index procedure alone, and after accounting for re-operations.

  2. Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate).

    PubMed

    Biazzo, Alessio; Cardile, Carlo; Brunelli, Luca; Ragni, Paolo; Clementi, Daniele

    2017-04-28

    The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (OrthofixR, Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature.

  3. Patella Fracture Fixation with Suture and Wire: you Reap what you Sew

    PubMed Central

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Introduction Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. Methods In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Results Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26 - 88 years). Patients had an average BMI of 26.48 (range 19 - 44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36 fractures repaired with a tension band fixation, 11 underwent secondary surgery due to hardware pain or fixation failure (30.6%). At one year, no difference was seen in knee range of motion between cohorts. All fractures healed radiographically. Those patients who required reoperation or removal of hardware had significantly diminished range of motion about their injured knee (p > 0.005). Conclusions Patients who sustain inferior pole patella fractures have limited options for fracture fixation. Suture repair is clinically acceptable, yielding similar results to patella fractures repaired with metal implants. Importantly, patients undergoing suture repair appear to have fewer hardware related postoperative complications than those receiving wire fixation for midpole fractures. PMID:25328461

  4. Patella fracture fixation with suture and wire: you reap what you sew.

    PubMed

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26-88 years). Patients had an average BMI of 26.48 (range 19-44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36 fractures repaired with a tension band fixation, 11 underwent secondary surgery due to hardware pain or fixation failure (30.6%). At one year, no difference was seen in knee range of motion between cohorts. All fractures healed radiographically. Those patients who required reoperation or removal of hardware had significantly diminished range of motion about their injured knee (p > 0.005). Patients who sustain inferior pole patella fractures have limited options for fracture fixation. Suture repair is clinically acceptable, yielding similar results to patella fractures repaired with metal implants. Importantly, patients undergoing suture repair appear to have fewer hardware related postoperative complications than those receiving wire fixation for midpole fractures.

  5. Use of borehole radar reflection logging to monitor steam-enhanced remediation in fractured limestone-results of numerical modelling and a field experiment

    USGS Publications Warehouse

    Gregoire, C.; Joesten, P.K.; Lane, J.W.

    2006-01-01

    Ground penetrating radar is an efficient geophysical method for the detection and location of fractures and fracture zones in electrically resistive rocks. In this study, the use of down-hole (borehole) radar reflection logs to monitor the injection of steam in fractured rocks was tested as part of a field-scale, steam-enhanced remediation pilot study conducted at a fractured limestone quarry contaminated with chlorinated hydrocarbons at the former Loring Air Force Base, Limestone, Maine, USA. In support of the pilot study, borehole radar reflection logs were collected three times (before, during, and near the end of steam injection) using broadband 100 MHz electric dipole antennas. Numerical modelling was performed to predict the effect of heating on radar-frequency electromagnetic (EM) wave velocity, attenuation, and fracture reflectivity. The modelling results indicate that EM wave velocity and attenuation change substantially if heating increases the electrical conductivity of the limestone matrix. Furthermore, the net effect of heat-induced variations in fracture-fluid dielectric properties on average medium velocity is insignificant because the expected total fracture porosity is low. In contrast, changes in fracture fluid electrical conductivity can have a significant effect on EM wave attenuation and fracture reflectivity. Total replacement of water by steam in a fracture decreases fracture reflectivity of a factor of 10 and induces a change in reflected wave polarity. Based on the numerical modelling results, a reflection amplitude analysis method was developed to delineate fractures where steam has displaced water. Radar reflection logs collected during the three acquisition periods were analysed in the frequency domain to determine if steam had replaced water in the fractures (after normalizing the logs to compensate for differences in antenna performance between logging runs). Analysis of the radar reflection logs from a borehole where the temperature increased substantially during the steam injection experiment shows an increase in attenuation and a decrease in reflectivity in the vicinity of the borehole. Results of applying the reflection amplitude analysis method developed for this study indicate that steam did not totally replace the water in most of the fractures. The observed decreases in reflectivity were consistent with an increase in fracture-water temperature, rather than the presence of steam. A limiting assumption of the reflection amplitude analysis method is the requirement for complete displacement of water in a fracture by steam. ?? 2006 Elsevier B.V. All rights reserved.

  6. 3D Simulation of Multiple Simultaneous Hydraulic Fractures with Different Initial Lengths in Rock

    NASA Astrophysics Data System (ADS)

    Tang, X.; Rayudu, N. M.; Singh, G.

    2017-12-01

    Hydraulic fracturing is widely used technique for extracting shale gas. During this process, fractures with various initial lengths are induced in rock mass with hydraulic pressure. Understanding the mechanism of propagation and interaction between these induced hydraulic cracks is critical for optimizing the fracking process. In this work, numerical results are presented for investigating the effect of in-situ parameters and fluid properties on growth and interaction of multi simultaneous hydraulic fractures. A fully coupled 3D fracture simulator, TOUGH- GFEM is used for simulating the effect of different vital parameters, including in-situ stress, initial fracture length, fracture spacing, fluid viscosity and flow rate on induced hydraulic fractures growth. This TOUGH-GFEM simulator is based on 3D finite volume method (FVM) and partition of unity element method (PUM). Displacement correlation method (DCM) is used for calculating multi - mode (Mode I, II, III) stress intensity factors. Maximum principal stress criteria is used for crack propagation. Key words: hydraulic fracturing, TOUGH, partition of unity element method , displacement correlation method, 3D fracturing simulator

  7. Single versus double row suture anchor fixation for greater tuberosity fractures - a biomechanical study.

    PubMed

    Seppel, Gernot; Saier, Tim; Martetschläger, Frank; Plath, Johannes E; Guevara-Alvarez, Alberto; Henschel, Julia; Winkler, Martin; Augat, Peter; Imhoff, Andreas B; Buchmann, Stefan

    2017-12-01

    Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Load to failure values were higher in the DR group (649 N; ±176) than in the SR group (490 N; ±145) however without statistical significance (p = .12). In greater tuberosity displacement of 3-5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; ±46 compared to 260 N; ±62 in the DR group (p = .65). The results suggest that both techniques are viable options for refixation of greater tuberosity fractures. Laboratory study.

  8. Is intramedullary nailing more effective than non-operative treatment in adults with displaced middle-third clavicle fractures?

    PubMed

    Hill, Christopher Edward

    2014-09-01

    Clavicle fractures are common, accounting for 5-12 % of all fractures. Traditionally, displaced middle-third clavicle fractures have been managed non-operatively but the associated displacement often leads to mal-union with shortening, cosmetic deformity and occasionally non-union, with clinicians looking towards alternative operative methods such as intramedullary nailing (IMN). However, such methods have their own complications. In order to ascertain the effectiveness of IMN in the management of middle-third clavicle fractures compared with non-operative treatment, analysis of recent evidence is required and this review aims to achieve that, focusing on relevant, contemporary randomised-control trials. Essential search-terms identified from the research question were used to formulate a search strategy. A systematic search of multiple databases was then performed from 1966 until present and appropriate papers for appraisal identified. Thirteen papers were identified, with 10 excluded using appropriate eligibility criteria. The remaining papers were then critically appraised. With regards shoulder function, all papers demonstrated an association between IMN and a significantly (P < 0.05) superior shoulder function score, but no consensus with regards to complication rates. However, all have identified limitations; therefore, their overall findings must be considered conservatively. Further, high-quality research, ideally in the form of well-designed, multi-centre RCTs is required to allow acceptable implementation of IMN of middle-third clavicle fractures into widespread practice. However, early results demonstrate that in young patients with displaced middle-third clavicle fractures, who are motivated to return to work, IMN provides superior functional results and should be considered. However, the importance of considering each patient individually as to their suitability for each management option, before coming to an informed decision with the patient rather than having a blanket approach to MTCF is essential. Level 1.

  9. Minimally invasive plate osteosynthesis technique for displaced midshaft clavicular fracture using the clavicle reductor.

    PubMed

    Zhang, Tao; Chen, Wei; Sun, Jiayuan; Zhang, Qi; Zhang, Yingze

    2017-08-01

    This study aims to introduce a self-designed clavicle reductor and to test the effectivity of a alternative minimally invasive plate osteosynthesis technique (MIPO) for displaced midshaft clavicular fractures (DMCFs) with the application of our self-designed clavicle reductor. From October 2012 to February 2013, 27 male patients who suffered with unilateral displaced midshaft clavicular fracture (DMCFs) were included into our study. Patients were treated by minimally invasive plate osteosynthesis (MIPO) technique with the application of our self-designed clavicle reductor and followed up regularly. Constant-Murley score was employed to test the functional outcomes at one year's follow up. The average follow-up time for the 27 patients was 15.8 months (range, 13-18 months). The average age of all patients was 32.6 (range, 21 to 48). According to OTC system, 12 cases were simple fractures (15-B1), ten cases were wedge fractures (15-B2) and five cases were comminuted fractures (15-B3). With the application of the clavicle reductor, minimally invasive plate osteosynthesis technique can be performed without any barrier in all of the 27 cases. Operative duration was 48.1 minutes (range, 35-65 minutes) and average fluoroscopy time was 12.8 seconds (range, from 7 to 22 seconds). All of the 27 cases healed from four to six months post-operatively. The average Constant-Murley-score of the 27 patients was 92.7 ± 5.88 (range, 80 to 100). No complications were noted. The self-designed clavicle reductor can effectively pave the way for the application of MIPO technique in the treatment of DMCFs. MIPO technique with locking reconstruction plate is a feasible and worthwhile alternative for displaced midshaft clavicular fractures (DMCFs).

  10. Intraobserver and interobserver agreement in the classification and treatment of midshaft clavicle fractures.

    PubMed

    Jones, Grant L; Bishop, Julie Y; Lewis, Brian; Pedroza, Angela D

    2014-05-01

    With the recent emphasis on performing open reduction and internal fixation on midshaft clavicle fractures with complete displacement, comminution, and >2 cm of shortening, it is important to determine the reliability of orthopaedic surgeons to assess these variables on standard plain radiographs and to determine the agreement among orthopaedic surgeons in choosing the treatment. To determine the intra- and interobserver reliability in the classification of midshaft clavicle fractures via standard plain radiographs and to determine the intra- and interobserver agreement in the treatment of these fractures. Cohort study (diagnosis); Level of evidence, 3. Charts of patients seen by the 2 senior authors from 2006 to 2011 were reviewed to identify patients treated for clavicle fractures (CPT codes 23500 and 23515). Anteroposterior and 30° cephalad radiographs were selected, representing midshaft clavicle fractures treated both operatively and nonoperatively. Thirty pairs of radiographs were included in the investigation. The radiographs were standardized for size to allow accurate measurements within a non-PACS (picture archiving and communications system) program, and a PDF document was created with all representative radiographs. Clinical scenarios were created for each set of radiographs, and the evaluators were asked to (1) measure the degree of shortening in millimeters, (2) determine the percentage displacement, (3) determine whether the fracture was comminuted, and (4) state whether they would treat the fracture operatively or nonoperatively. The radiographs, along with instructions on how to use the measuring tool with Adobe Reader, were distributed to 22 shoulder/sports medicine fellowship-trained orthopaedic surgeons, then reordered and redistributed approximately 3 months later. Sixteen surgeons completed 1 round of surveys, and 13 surgeons completed both rounds. Interrater agreement was moderate for displacement of 0%-49% (κ = 0.71, P < .001) and >100% (κ = 0.73, P < .001), with minimal agreement for displacement of 50%-100% (κ = 0.39, P < .001). There was moderate interrater agreement for the presence/absence of comminution (κ = 0.75, P < .001). Interrater agreement was weak for shortening of 0-5.0 mm (κ = 0.58, P < .001) and >30.0 mm (κ = 0.51, P < .001), with minimal agreement for shortening of 5.1-10.0 mm (κ = 0.22, P < .001) and no agreement for the other 4 categories. Interrater analysis showed weak agreement on whether surgical treatment was recommended (κ = 0.40, P < .001). Intrarater agreement was strong for comminution (κ = 0.80, P < .0001), moderate for both displacement (κ = 0.76, P < .001) and operative treatment (κ = 0.64, P < .001), and minimal for shortening (κ = 0.38, P < .001). The following variables statistically predicted whether surgery was recommended (P < .001): (1) the odds of surgery were 2.26 if comminution was noted, holding displacement and the interaction between displacement and shortening constant, and (2) the odds of surgery were 3.37 if there is displacement of >100% compared with displacement of 0%-49%, holding comminution and shortening constant. Standard plain unilateral radiographs of the clavicle are insufficient to reliably determine the degree of shortening of clavicle fractures and the need for surgery among shoulder/sports medicine fellowship-trained orthopaedic surgeons. Consideration should be made to not use shortening as the sole determinant for whether to proceed with surgical intervention or to use other radiographic modalities to determine the amount of shortening.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ball, J.B. Jr.

    Direct oblique sagittal CT was used to evaluate trauma to 77 orbits. Sixty-seven orbital wall fractures with intact orbital rims (36 floor, 22 medial wall, nine roof) were identified in 47 orbits. Since persistent diplopia and/or enophthalmos may warrant surgical repair of orbital floor fractures, optimal imaging should include an evaluation of extraocular muscle status, the nature and amount of displaced orbital contents, and an accurate definition of fracture margins. For orbital floor fractures, a combination of the direct oblique sagittal and direct coronal projections optimally displayed all fracture margins, the fracture's relationship to the inferior orbital rim and medialmore » orbital wall, and the amount of displacement into the maxillary sinus. Inferior rectus muscle status with 36 floor fractures was best seen on the direct oblique sagittal projection in 30 fractures (83.3%) and was equally well seen on sagittal and coronal projections in two fractures (5.5%). Floor fractures were missed on 100% of axial, 5.5% of sagittal, and 0% of coronal projections. Since the direct oblique sagittal projection complements the direct coronal projection in evaluating orbital floor fractures, it should not be performed alone. A technical approach to the CT evaluation or orbital wall fractures is presented.« less

  12. Modeling the Impact of Fracture Growth on Fluid Displacements in Deformable Porous Media

    NASA Astrophysics Data System (ADS)

    Santillán, D.; Cueto-Felgueroso, L.; Juanes, R.

    2015-12-01

    Coupled flow and geomechanics is a critical research challenge in engineering and the geosciences. The flow of a fluid through a deformable porous media is present in manyenvironmental, industrial, and biological processes,such as the removal of pollutants from underground water bodies, enhanced geothermal systems, unconventional hydrocarbon resources or enhanced oil recovery techniques. However, the injection of a fluid can generate or propagate fractures, which are preferential flow paths. Using numerical simulation, we study the interplay between injection and rock mechanics, and elucidate fracture propagation as a function of injection rate, initial crack topology and mechanical rock properties. Finally, we discuss the role of fracture growth on fluid displacements in porous media. Figure: An example of fracture (in red) propagated in a porous media (in blue)

  13. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    PubMed

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland-Altman plot, there were no statistical significant difference (P<0.05). Images from the sonography could provide visualization of the fracture during reduction and MIPO as accurately as the radiography. Thus, the sonography assisted MIPO in femoral shaft fracture can be done effectively comparing with radiographic assisted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Mandibular fracture patterns consistent with posterior maxillary fractures involving the posterior maxillary sinus, pterygoid plate or both: CT characteristics

    PubMed Central

    Sukegawa, S; Kanno, T; Fujita, G; Yamamoto, N; Furuki, Y; Michizawa, M

    2014-01-01

    Objectives: The aim of this study was to determine the incidence of posterior maxillary fractures involving the posterior maxillary sinus wall, pterygoid plate or both, unrelated to major midface fractures in patients with mandibular fractures, and to characterize associated fractures. Methods: A CT study was performed in patients with mandibular fractures to identify posterior maxillary fractures. Patients aged under 16 years, those with mandibular fractures involving only dentoalveolar components and those with concurrent major midfacial fractures were excluded. Results: 13 (6.7%) of 194 patients with mandibular fractures also had posterior maxillary fractures (case group). The injury pattern correlated with the external force directed to the lateral side of the mandible (p < 0.001), alcohol consumption (p = 0.049), the presence of multifocal fractures (p = 0.002) and the fracture regions in the symphysis/parasymphysis (p = 0.001) and the angle/ramus (p = 0.001). No significant difference between the case and non-case groups was seen for age, sex or cause of trauma. Non-displaced fractures in the ipsilateral posterior mandible occurred with significant frequency (p = 0.001) when the posterior maxillary fractures involved only the sinus. Conclusions: Mandibular fractures accompanied by posterior maxillary fractures are not rare. The finding of a unilateral posterior maxillary fracture on CT may aid the efficient radiological examination of the mandible based on possible patterns of associated fractures, as follows: in the ipsilateral posterior region as a direct fracture when the impact is a medially directed force, and in the symphysis/parasymphysis or contralateral condylar neck as an indirect fracture. PMID:24336313

  15. [Isolated Displaced Fracture of the Acromion - Case Report].

    PubMed

    Krtička, M; Ira, D

    2016-01-01

    Displaced fractures of the acromion are rare injuries. A 45-year-old lady presented with an isolated acromion fracture (type III, Kuhn classification) resulting from a direct blow to the top of her right shoulder in a fall while skiing. After standard clinical and radiological examination of the shoulder, an open reduction and internal plate fixation using a postero-superior approach to the scapula was performed. Early rehabilitation of the arm and shoulder was initiated. At 50 days after surgery the patient achieved a full range of motion in her right shoulder and muscle strength equal to that of the contralateral extremity. By 12 weeks radiographic union of the fracture was recorded. The final functional outcome after open reduction and internal plate fixation of the fracture was comparable with results reported in the literature and, in comparison with conservative treatment, the risk of non-union was significantly reduced. acromion fracture, scapula, osteosynthesis.

  16. Rupture models with dynamically determined breakdown displacement

    USGS Publications Warehouse

    Andrews, D.J.

    2004-01-01

    The critical breakdown displacement, Dc, in which friction drops to its sliding value, can be made dependent on event size by specifying friction to be a function of variables other than slip. Two such friction laws are examined here. The first is designed to achieve accuracy and smoothness in discrete numerical calculations. Consistent resolution throughout an evolving rupture is achieved by specifying friction as a function of elapsed time after peak stress is reached. Such a time-weakening model produces Dc and fracture energy proportional to the square root of distance rupture has propagated in the case of uniform stress drop. The second friction law is more physically motivated. Energy loss in a damage zone outside the slip zone has the effect of increasing Dc and limiting peak slip velocity (Andrews, 1976). This article demonstrates a converse effect, that artificially limiting slip velocity on a fault in an elastic medium has a toughening effect, increasing fracture energy and Dc proportionally to rupture propagation distance in the case of uniform stress drop. Both the time-weakening and the velocity-toughening models can be used in calculations with heterogeneous stress drop.

  17. The use of resorbable plates in association with dental arch stabilization in the treatment of mandibular fractures in children.

    PubMed

    Li, Zhi; David, Ongodia; Li, Zu-Bing

    2014-07-01

    The purpose of this study was to investigate the effect of resorbable plate fixation in association with dental arch stabilization in the treatment of displaced mandibular fractures in children. Thirteen children (5 girls and 8 boys, age range 2 years 5 months to 12 years 2 months) with displaced mandibular fractures were included in this case series. Open reduction by intraoral approach was performed on these patients, and the fractures were fixed using resorbable plates and monocortical screws placed at the lower border of the mandible. At the same time, an arch bar or orthodontic wire splint was anchored using stainless steel wires or resin on the teeth to stabilize the whole mandibular dental arch. Postoperatively, follow-up was undertaken to evaluate the fracture healing, mandible movement, and mandible growth. Postoperatively, all patients achieved uneventful healing; premorbid occlusion restoration and wound healing were achieved, along with unimpaired function and normal growth and development of the mandible. Complications such as damage to tooth buds, infection, malunion, and nonunion were not encountered in these patients. Resorbable plates use in association with dental arch stabilization can provide good stabilization for mandibular fractures and is a promising approach for the treatment of displaced mandibular fractures in children. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Deep tissue imaging of microfracture and non-displaced fracture of bone using the second and third near-infrared therapeutic windows

    NASA Astrophysics Data System (ADS)

    Sordillo, Laura A.; Pu, Yang; Sordillo, P. P.; Budansky, Yury; Alfano, Robert R.

    2014-03-01

    Near-infrared (NIR) light in the wavelengths of 700 nm to 2,000 nm has three NIR optical, or therapeutic, windows, which allow for deeper depth penetration in scattering tissue media. Microfractures secondary to repetitive stress, particularly in the lower extremities, are an important problem for military recruits and athletes. They also frequently occur in the elderly, or in patients taking bisphosphonates or denosumab. Microfractures can be early predictors of a major bone fracture. Using the second and third NIR therapeutic windows, we investigated the results from images of chicken bone and human tibial bone with microfractures and non-displaced fractures with and without overlying tissues of various thicknesses. Images of bone with microfractures and non-displaced fractures with tissue show scattering photons in the third NIR window with wavelengths between 1,650 nm and 1,870 nm are diminished and absorption is increased slightly from and second NIR windows. Results from images of fractured bones show the attenuation length of light through tissue in the third optical window to be larger than in the second therapeutic window. Use of these windows may aid in the detection of bone microfractures, and thus reduce the incidence of major bone fracture in susceptible groups.

  19. Clavicle fracture associated with atlantoaxial rotatory displacement, type II in an 8-year-old girl: A case report.

    PubMed

    Karski, Jacek; Matuszewski, Łukasz; Jakubowski, Paweł; Karska, Klaudia; Kandzierski, Grzegorz

    2017-11-01

    Fracture of the clavicle is a very common injury in children. However, association between clavicle fracture and atlantoaxial rotatory displacement is rarely observed. We present a case of an 8-year-old girl, who suffered a right clavicle fracture as a result of a sledge accident. Six weeks after figure of 8 casting for a right clavicle fracture, an 8-year-old girl was brought to the Pediatric Orthopedic Department due to torticollis. Standard X-ray examination revealed nonunion of the clavicle without any clinical symptoms. Computed tomography (CT) examination was performed and subluxation of cervical vertebrae 1/cervical vertebrae 2 was detected. The use of Glisson's traction followed by a soft cervical collar resulted in the resolution of all the symptoms. Control CT and magnetic resonance imaging confirmed reduction. The patient fully recovered and currently is fully active. The neurological status of the child before and after procedure remained normal. Clavicle fracture rarely may be associated with atlantoaxial rotatory displacement. Therefore, careful examination including rotation of the neck is necessary to confirm that associations. Moreover, three-dimensional CT scan enables proper spine examination and provides correct diagnosis. As shown in available literature and as well in presented case report, none operative treatment is usually effective.

  20. Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

    PubMed Central

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    The incidence of condylar fractures is high, but the management of fractures of the mandibular condyle continues to be controversial. Historically, maxillomandibular fixation, external fixation, and surgical splints with internal fixation systems were the techniques commonly used in the treatment of the fractured mandible. Condylar fractures can be extracapsular or intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on the age of the patient, the co-existence of other mandibular or maxillary fractures, whether the condylar fracture is unilateral or bilateral, the level and displacement of the fracture, the state of dentition and dental occlusion, and the surgeonnds on the age of the patient, the co-existence of othefrom which it is difficult to recover aesthetically and functionally;an appropriate treatment is required to reconstruct the shape and achieve the function ofthe uninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, and complication prevention are required. In particular, as mandibular condyle fracture may cause long-term complications such as malocclusion, particularly open bite, reduced posterior facial height, and facial asymmetry in addition to chronic pain and mobility limitation, great caution should be taken. Accordingly, the authors review a general overview of condyle fracture. PMID:22872830

  1. Three-dimensional effects in nonlinear fracture explored with interferometry

    NASA Astrophysics Data System (ADS)

    Pfaff, Richard D.

    The prospects for understanding fracture mechanics in terms of a general material constitutive description are explored. The effort consists of three distinct components.First, optical interferometry, in its various forms (Twyman-Green, diffraction moire, etc.), can potentially be used under a wide range of conditions to very accurately measure the displacement and strain fields associated with the deformation surrounding a cracktip. To broaden the range of fracture problems to which interferometry may be applied, certain of the necessary experimental improvements have been developed:1. High speed camera designs capable of extremely high (> 10(9) frames/second) framing rates with large array sizes, (> 4000 x 4000 pixels per frame) so that the application of optical techniques to solid mechanics may be considered without limitation on the rate of deformation.2. An accurate and adaptable device for dynamic loading of fracture specimens to high load levels utilizing electromagnetic (Lorentz force) loading with ultrahigh (> 2,000,000 Amp/cm(2)) current flux densities.3. Implementation of high sensitivity (2 nm), large range (2 nm x 3,200,000) interferometry achieved with wide field array sizes of 50,000 x 50,000 and 8 bit gray scale (error restricted to 1 bit) for surface deformation measurements on fracture specimens.Second, functional descriptions for certain aspects of the displacement fields associated with fracture specimens are developed. It is found that the fully three-dimensional crack tip field surrounding a through-thickness crack in a plate of elastic-plastic material shows a hierarchical structure of organization and that the primary aspects of the deformation field would seem to have a relatively simple form of expression if the deformation is viewed in a properly normalized form.Third, a comparison is made between interferometrically measured surface displacements for a notched 3-point-bend speciemn of a ductile heat treatment of 4340 steel and a numerical simulation of the specimen based on a material constitutive description determined from uniaxial tests performed on the same material. The small but finite notch tip radius (0.15 mm) fabricated by a wire-cutting electrical discharge machine allows one to explore the limits of applicability of standard continuum plasticity theories without involving a process zone model for the very near tip region extent in a cracked specimen geometry.

  2. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.

    PubMed

    Sohn, Hoon-Sang; Kim, Won Ju; Shon, Min Soo

    2015-08-01

    Current literatures describe good clinical outcomes of acute displaced fracture of clavicle treated with minimally invasive plate osteosynthesis (MIPO). But, there are little comparative data of the outcomes between open plating and MIPO techniques. We compared the outcomes of open plating and MIPO for treatment of acute displaced clavicular shaft fractures. The author performed a retrospective review on a consecutive series of patients with clavicular shaft fracture who underwent open plating or MIPO. Fourteen patients were treated with open plating with interfragmentary screw fixation, and 19 were treated with the MIPO technique without exposing a fracture site itself. A superior plating method was applied to both groups. Patient demographics, clinical outcomes using Constant score and University of California Los Angeles (UCLA) shoulder score, operation time, union rate, complications, and radiographic evaluation were evaluated. There were no statistically significant differences in the demographic data, including patient's variables (age, gender, involved side, smoking, alcohol, and diabetic status) and fracture characteristics (trauma mechanism, distribution of fracture type, presence of polytrauma, and time from trauma to surgery) between the two groups. Mean operation time was 87.5 min in open plating and 77.2 min in MIPO (p=0.129). The mean time to union was 15.7 weeks in patients who underwent open plating and 16.8 weeks in patients who underwent MIPO (p=0.427). Although there was no significant difference, nonunion developed 1 case in MIPO while none was in open plating. Four patients in open plating had skin numbness (none in MIPO, p=0.024). There was no significant difference in the Constant score and UCLA score of the two surgical methods. This study showed that both open plating with interfragmentary screw fixation (Open plating) and minimally invasive plate osteosynthesis (MIPO) are equally effective and safe treatment methods for acute displaced clavicle shaft fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Is intramedullary fixation of displaced midshaft clavicle fracture superior to plate fixation? Evidence from a systematic review of discordant meta-analyses.

    PubMed

    Xu, Bin; Lin, Yongsheng; Wang, Zhihong; Cao, Junming; Yang, Yipeng; Xia, Hehuan; Zhang, Yingze

    2017-07-01

    An increasing number of meta-analyses comparing intramedullary fixation (IF) with plate fixation (PF) for displaced midshaft clavicle fracture have been reported, but the inconsistent results obtained might confuse decision-making. We systematically reviewed discordant meta-analyses for assisting the decision-maker in interpreting and selecting amongst discordant meta-analyses and providing surgical recommendations for displaced midshaft clavicle fracture according to currently best available evidence. Meta-analyses on IF and PF for displaced midshaft clavicle fracture were identified by searching PubMed, Emabase and the Cochrane Library. A review of meta-analysis quality and data extraction was individually conducted by two reviewers. The meta-analysis providing the best available evidence was identified using the Jadad decision algorithm. Nine studies were included, five of which were of Level-II evidence and four of which were of Level-III evidence. These meta-analyses scored from 6 to 10 according to the Assessment of Multiple Systematic Reviews instrument. With respect to the Jadad decision algorithm, the best meta-analysis was chosen depending upon publication characteristics and methodology of primary studies, language restrictions, and whether data on individual patients were analysed. A meta-analysis incorporating more randomised controlled trials was eventually selected. The best available evidence indicated that the differences between IF and PF were not significant in terms of shoulder function or the rate of treatment failure. However, IF significantly decreased the operative time and the rate of non-operative complications, especially the rate of infection. Based on the best available evidence, IF may be superior to PF for treating displaced midshaft clavicle fracture. Copyright © 2017. Published by Elsevier Ltd.

  4. A Prolonged Time Interval Between Trauma and Prophylactic Radiation Therapy Significantly Increases the Risk of Heterotopic Ossification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mourad, Waleed F., E-mail: Waleed246@gmail.com; Department of Radiation Oncology, Beth Israel Medical Center, New York, NY; Packianathan, Satyaseelan

    2012-03-01

    Purpose: To ascertain whether the time from injury to prophylactic radiation therapy (RT) influences the rate of heterotopic ossification (HO) after operative treatment of displaced acetabular fractures. Methods and Materials: This is a single-institution, retrospective analysis of patients referred for RT for the prevention of HO. Between January 2000 and January 2009, 585 patients with displaced acetabular fractures were treated surgically followed by RT for HO prevention. We analyzed the effect of time from injury on prevention of HO by RT. In all patients, 700 cGy was prescribed in a single fraction and delivered within 72 hours postsurgery. The patientsmore » were stratified into five groups according to time interval (in days) from the date of their accident to the date of RT: Groups A {<=}3, B {<=}7, C {<=}14, D {<=}21, and E >21days. Results: Of the 585 patients with displaced acetabular fractures treated with RT, (18%) 106 patients developed HO within the irradiated field. The risk of HO after RT increased from 10% for RT delivered {<=}3 days to 92% for treatment delivered >21 days after the initial injury. Wilcoxon test showed a significant correlation between the risk of HO and the length of time from injury to RT (p < 0.0001). Chi-square test and multiple logistic regression analysis showed no significant association between all other factors and the risk of HO (race, gender, cause and type of fracture, surgical approach, or the use of indomethacin). Conclusions: Our data suggest that there is higher incidence and risk of HO if prophylactic RT is significantly delayed after a displaced acetabular fracture. Thus, RT should be administered as early as clinically possible after the trauma. Patients undergoing RT >3 weeks from their displaced acetabular fracture should be informed of the higher risk (>90%) of developing HO despite prophylaxis.« less

  5. Isolated displaced non-union of a triquetral body fracture: a case report

    PubMed Central

    2012-01-01

    Introduction Fractures of the body of the triquetral bone are the second most common carpal fractures, and these fractures can be missed on plain X-ray. Although non-union of triquetral body fractures is very rare, such cases are associated with considerable morbidity and reduction in functional activity. Case presentation We report the case of a 29-year-old Caucasian British man who sustained an isolated displaced triquetral body fracture that resulted in non-union, who was treated surgically. We describe an original operative management for this debilitating injury. An open reduction and internal fixation using double headed compression screws was performed, without bone grafting, and with early immobilization of the wrist. Conclusions We propose this novel approach and advocate early clinical suspicion of triquetral body fractures in patients with a history of fall on an outstretched hand and ulnar sided wrist pain. We recommend evaluation using computed tomography or magnetic resonance imaging scanning. PMID:22325450

  6. Modified arthroscopic suture fixation of a displaced tibial eminence fracture.

    PubMed

    Lehman, Ronald A; Murphy, Kevin P; Machen, M Shaun; Kuklo, Timothy R

    2003-02-01

    This study describes a new arthroscopic method using a whip-stitch technique for treating a displaced type III tibial eminence fracture. A 12-year-old girl who sustained a displaced type III tibial eminence fracture was treated with arthroscopic fixation using the Arthrosew disposable suture device (Surgical Dynamics, Norwalk, CT) to place a whip stitch into the anterior cruciate ligament (ACL). The Arthrex ACL guide (Arthrex, Naples, FL) was used to reduce the avulsed tibial spine fragment. Sutures were then passed through the tibial tunnel and secured over a bony bridge with the knee in 20 degrees of flexion. At 9 months, the patient has a full range of motion with normal Lachman and anterior drawer testing, and she has returned to competitive basketball. Radiographs show complete fracture healing. KT-1000 and isokinetic testing at 9-month follow-up show only minimal side-to-side differences. The Arthrosew device provides a significant advantage in the treatment of type III and IV fractures of the tibial eminence by obtaining arthroscopic fixation within the substance of the ACL, thus obviating arthrotomy and hardware placement. This technique also restores the proper length and tension to the ACL, and provides a simplified, reproducible method of treatment for this injury.

  7. Mortality Rates Following Posterior C1-2 Fusion for Displaced Type II Odontoid Fractures in Octogenarians.

    PubMed

    Clark, Stephen; Nash, Alysa; Shasti, Mark; Brown, Luke; Jauregui, Julio J; Mistretta, Katherine; Koh, Eugene; Banagan, Kelley; Ludwig, Steven; Gelb, Daniel

    2018-03-13

    Retrospective cohort study OBJECTIVE.: To assess 30-day and one-year mortality rates as well as the most common complications associated with posterior C1-2 fusion in an octogenarian cohort. Treatment of unstable type II odontoid fractures in elderly patients can present challenges. Recent evidence indicates in patients older than 80 years, posterior C1-2 fusion results in improved survival as compared to other modes of treatment. Retrospective analysis of 43 consecutive patients (25 F and 18 M; mean age 84.3y, range 80-89y; mean Charlson Comorbidities Index 1.4, (range 1-6); mean BMI 24.8 ± 4.2 kg/m2, who underwent posterior C1-C2 fusion for management of unstable type II odontoid fracture by 4 fellowship trained spine surgeons at a single institution between January 2006-June 2016. Mean fracture displacement was 5.1 ± 3.6 mm and mean absolute value of angulation was 19.93 ± 12.93°. The most common complications were altered mental status (41.9%, n = 18), dysphagia (27.9%, n = 12) with 50% of those patients (6 of 12) requiring a feeding tube, and emergency reintubation (9.3%, n = 4). To the date of review completion, 25 of 43 patients expired (58.1%), median survival of 1.76 years from the date of surgery. Thirty-day and one-year mortality rates were 2.3% and 18.6%, respectively. Patients who developed dysphagia were 14.5 times more likely to have expired at 1 year; dysphagia was also found to be significantly associated with degree of displacement. Fracture displacement was found to be associated with increased odds for 1-year mortality when accounting for age and requirement of a feeding tube. Posterior C1-2 fusion results in acceptably low mortality rates in octogenarians with unstable type II odontoid fractures when compared to non-operative management mortality rates in current literature. Initial fracture displacement is associated with higher mortality rate in this patient population. 4.

  8. Coupled Modeling of Flow, Transport, and Deformation during Hydrodynamically Unstable Displacement in Fractured Rocks

    NASA Astrophysics Data System (ADS)

    Jha, B.; Juanes, R.

    2015-12-01

    Coupled processes of flow, transport, and deformation are important during production of hydrocarbons from oil and gas reservoirs. Effective design and implementation of enhanced recovery techniques such as miscible gas flooding and hydraulic fracturing requires modeling and simulation of these coupled proceses in geologic porous media. We develop a computational framework to model the coupled processes of flow, transport, and deformation in heterogeneous fractured rock. We show that the hydrocarbon recovery efficiency during unstable displacement of a more viscous oil with a less viscous fluid in a fractured medium depends on the mechanical state of the medium, which evolves due to permeability alteration within and around fractures. We show that fully accounting for the coupling between the physical processes results in estimates of the recovery efficiency in agreement with observations in field and lab experiments.

  9. Study of the X-Ray Diagnosis of Unstable Pelvic Fracture Displacements in Three-Dimensional Space and its Application in Closed Reduction.

    PubMed

    Shi, Chengdi; Cai, Leyi; Hu, Wei; Sun, Junying

    2017-09-19

    ABSTRACTS Objective: To study the method of X-ray diagnosis of unstable pelvic fractures displaced in three-dimensional (3D) space and its clinical application in closed reduction. Five models of hemipelvic displacement were made in an adult pelvic specimen. Anteroposterior radiographs of the pelvis were analyzed in PACS. The method of X-ray diagnosis was applied in closed reductions. From February 2012 to June 2016, 23 patients (15 men, 8 women; mean age, 43.4 years) with unstable pelvic fractures were included. All patients were treated by closed reduction and percutaneous cannulate screw fixation of the pelvic ring. According to Tile's classification, the patients were classified into type B1 in 7 cases, B2 in 3, B3 in 3, C1 in 5, C2 in 3, and C3 in 2. The operation time and intraoperative blood loss were recorded. Postoperative images were evaluated by Matta radiographic standards. Five models of displacement were made successfully. The X-ray features of the models were analyzed. For clinical patients, the average operation time was 44.8 min (range, 20-90 min) and the average intraoperative blood loss was 35.7 (range, 20-100) mL. According to the Matta standards, 7 cases were excellent, 12 cases were good, and 4 were fair. The displacements in 3D space of unstable pelvic fractures can be diagnosed rapidly by X-ray analysis to guide closed reduction, with a satisfactory clinical outcome.

  10. Plain film measurement error in acute displaced midshaft clavicle fractures

    PubMed Central

    Archer, Lori Anne; Hunt, Stephen; Squire, Daniel; Moores, Carl; Stone, Craig; O’Dea, Frank; Furey, Andrew

    2016-01-01

    Background Clavicle fractures are common and optimal treatment remains controversial. Recent literature suggests operative fixation of acute displaced mid-shaft clavicle fractures (DMCFs) shortened more than 2 cm improves outcomes. We aimed to identify correlation between plain film and computed tomography (CT) measurement of displacement and the inter- and intraobserver reliability of repeated radiographic measurements. Methods We obtained radiographs and CT scans of patients with acute DMCFs. Three orthopedic staff and 3 residents measured radiographic displacement at time zero and 2 weeks later. The CT measurements identified absolute shortening in 3 dimensions (by subtracting the length of the fractured from the intact clavicle). We then compared shortening measured on radiographs and shortening measured in 3 dimensions on CT. Interobserver and intraobserver reliability were calculated. Results We reviewed the fractures of 22 patients. Bland–Altman repeatability coefficient calculations indicated that radiograph and CT measurements of shortening could not be correlated owing to an unacceptable amount of measurement error (6 cm). Interobserver reliability for plain radiograph measurements was excellent (Cronbach α = 0.90). Likewise, intraobserver reliabilities for plain radiograph measurements as calculated with paired t tests indicated excellent correlation (p > 0.05 in all but 1 observer [p = 0.04]). Conclusion To establish shortening as an indication for DMCF fixation, reliable measurement tools are required. The low correlation between plain film and CT measurements we observed suggests further research is necessary to establish what imaging modality reliably predicts shortening. Our results indicate weak correlation between radiograph and CT measurement of acute DMCF shortening. PMID:27438054

  11. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. The evolution of fabric with displacement in natural brittle faults

    NASA Astrophysics Data System (ADS)

    Mittempergher, S.; Di Toro, G.; Gratier, J.; Aretusini, S.; Boullier-Bertrand, A.

    2011-12-01

    In experiments performed at room temperature on gouges, a characteristic clast size distribution (CSD) is produced with increasing strain, and shear localization is documented to begin after few millimetres of sliding. But in natural faults active at depth in the crust, mechanical processes are associated with fluid-rock interactions, which might control the deformation and strength recovery. We aim to investigate the microstructural, geochemical and mineralogical evolution of low-displacement faults with increasing shear strain. The faults (cataclasite- and pseudotachylyte-bearing) are hosted in tonalite and were active at 9-11 km and 250-300°C. The samples were collected on a large glacier-polished outcrop, where major faults (accommodating up to 4300 mm of displacement) exploit pre-existing magmatic joints and are connected by a network of secondary fractures and faults (accommodating up to 500 mm of displacement) breaking intact tonalite. We performed optical and cathodoluminescence (CL) microscope, Scanning Electron Microscope (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Rietveld X-Ray Powder Diffraction and microprobe chemical analysis in deformation zones of secondary faults with various offsets in order to evaluate the transfer of chemical species between dissolution zones and protected zones. Image analysis techniques were applied on SEM-BSE and optical microscope images to compute the CSD in samples, which experienced an increasing amount of strain. The secondary fractures are up to 5 mm thick. Within the first 20 mm of displacement, shear localizes along Y and R1 surfaces and a cataclastic foliation develops. The CSD evolves from a fractal dimension D of 1.3 in fractures without visible displacement to values above 2 after the first 500 mm of displacement. Chemical maps and CL images indicate that the foliation in cataclasite results from the rotation and fragmentation of clasts, with dissolution of quartz and passive concentration of Ti oxides and titanite in the foliation planes. The cataclasites are cemented by pervasive precipitation of K-feldspar plagues and idiomorphic, randomly oriented, epidote and chlorite. We conclude that the textures of these small displacement (< 500 mm) faults are controlled by brittle processes (fracture propagation and cataclastic comminution) similar to those reproduced in friction experiments performed on granite gouge (e.g., Beeler et al., 1996; Logan, 2007). Then progressively, stress driven fluid-rock reactions develop as fracturing and grain size reduction allows the kinetics of these reactions to be more efficient and fracture interconnection allows fluid infiltration. Healing of microfractures and fault rock cementation caused a rapid posteismic recovery of fault strength. References Beeler, N.M., Tullis, T.E., Blanpied, L., Weeks, J.D., 1996. Frictional behaviour of large displacement experimental faults. Journal of Geophysical Research 101, B4, 8697-8715. Logan, J.M., 2007. The progression from damage to localization of displacement observed in laboratory testing of porous rocks, in Lewis, H., and Couples, G.D. (eds.) The relationship between damage and localization. Geological Society of London Special Publication 289, 75-87.

  13. Fracture mechanics criteria for turbine engine hot section components

    NASA Technical Reports Server (NTRS)

    Meyers, G. J.

    1982-01-01

    The application of several fracture mechanics data correlation parameters to predicting the crack propagation life of turbine engine hot section components was evaluated. An engine survey was conducted to determine the locations where conventional fracture mechanics approaches may not be adequate to characterize cracking behavior. Both linear and nonlinear fracture mechanics analyses of a cracked annular combustor liner configuration were performed. Isothermal and variable temperature crack propagation tests were performed on Hastelloy X combustor liner material. The crack growth data was reduced using the stress intensity factor, the strain intensity factor, the J integral, crack opening displacement, and Tomkins' model. The parameter which showed the most effectiveness in correlation high temperature and variable temperature Hastelloy X crack growth data was crack opening displacement.

  14. Delayed fixation of displaced bilateral, atraumatic, femoral neck fractures in a patient with pregnancy related osteomalacia.

    PubMed

    Docker, Charles; Starks, Ian; Wade, Roger; Wynn-Jones, Charles

    2011-06-01

    We present the case of a woman diagnosed with simultaneous displaced intracapsular femoral neck fractures following the birth of her second child. No traumatic event was identified. Diagnosis was delayed as the cause of her pain was thought to be non-skeletal in origin. Radiological and serological investigations were diagnostic of osteomalacia. Surgical fixation of her fractures was further delayed due to profound hypocalcaemia. Despite the delays, fixation with bilateral dynamic hip screws resulted in union with no evidence of avascular necrosis at 2 years follow-up. We believe this to be the first report of atraumatic bilateral femoral neck fractures and it shows that a good result can be achieved even in the presence of delayed fixation.

  15. [Osteosynthesis of distal radius fractures by doral plate: advantages and disadvantages].

    PubMed

    Obert, L; Vichard, P; Garbuio, P; Tropet, Y

    2001-12-01

    Distal radius fractures remain a challenge. No one osteosynthesis procedure can solve all the problems. A method of analysis is necessary in order to choose the best tools. Open treatment of the fracture is logical but rarely performed. A review of the literature and the experience of the authors are reported in order to analyse the correct place of dorsal plating in distal radius fracture with dorsal displacement. The learning curve of the operative procedure and the design of the implants can explain the occurrence of several complications. The dorsal plate is effective against secondary dorsal displacement. This demanding procedure must be compared with other reported procedures (pining and external fixator) to define the advantages and disadvantages.

  16. MX Siting Investigation Geotechnical Evaluation Verification Study - Pine Valley Utah. Volume I. Synthesis.

    DTIC Science & Technology

    1981-03-24

    north-south trending alluvial basin. The Wah Wah Mountains to the east consist principally of Paleozoic limestones, dolomites , and quartzites with minor...zone of fracture along which there has been displacement. FAULT BLOCK MOUNTAINS - Mountains that are formed by normal faulting in which the surface...sample (ASTM D 2850-70). To conduct the test, a cylindrical specimen of soil is surrounded by a fluid in a pressure chamber and subjected to an isotropic

  17. MX Siting Investigation. Geotechnical Evaluation. Verification Study - Pahroc Valley, Nevada. Volume I. Synthesis.

    DTIC Science & Technology

    1981-06-30

    Range both consist of Paleozoic limestone and dolomite overlain by Tertiary ash-flow tuffs and undiffer- entiated volcanic rocks. The central portion...andesite, detrital material, volcanic tuff, pumice). FAULT - A plane or zone of fracture along which there has been * I displacement. FAULT BLOCK...D2850-70). To conduct the test, a cylindrical specimen of soil is surrounded by a fluid in a pressure chamber and subjected to an isotropic pressure . An

  18. Morphology of the posteromedial fragment in pertrochanteric fractures: A three-dimensional computed tomography analysis.

    PubMed

    Sharma, Gaurav; Gn, Kiran Kumar; Khatri, Kavin; Singh, Ravijot; Gamanagatti, Shivanand; Sharma, Vijay

    2017-02-01

    In this study we describe the morphology of the posteromedial fragment in pertrochanteric fractures using 3D CT scans and answer two questions 1) Do differences exist between the 3D CT appearances of posteromedial fragments and the depictions made in the AO classification 2) Does the posteromedial fragment affect stability in pertrochanteric fractures, in terms of fracture collapse? Preoperative CT scans of eight 31-A1 and fifty 31-A2 fractures were analysed. The presence of PM fragment, its fragmentation, greater trochanter (GT) involvement, lesser trochanter (LT) fragment size (in terms of its posterior and medial extent as well as LT length), LT fragment displacement (in terms of medial displacement and rotation) were determined. All fractures were treated with a DHS. Fracture collapse was determined on postoperative radiographs. The relationship between fracture collapse and patient factors including age, gender, fracture type (A1 versus A2), characteristics of the posteromedial fragment, and the presence of a lateral wall fracture were determined. Three out of eight 31-A1 fractures demonstrated a separate GT fragment (three part fracture). Out of the 50 31-A2 fractures, 12 had a single PM fragment, which included the LT and GT in continuity. The more common four part fractures seem to form by further fragmentation of this basic form. In A2 fractures, the GT was almost always broken and the broken fragment comprised a mean 56% of normal GT. The LT fragment involved an average of 74% of the posterior wall, and an average of 36% of the medial wall of the proximal femur. Larger LT fragments were less displaced as compared to smaller fragments. Univariate regression analyses revealed that fracture collapse was significantly correlated with fracture type (A1 versus A2, p 0.036), GT size (p 0.002) and the presence of a lateral wall fracture (p<0.001). This study revealed some important differences between the 3D CT appearances and AO classification of pertrochanteric fractures. Further, neither fragmentation of the posteromedial fragment, nor the size of the lesser trochanter fragment was found to predict stability in pertrochanteric fractures. A perioperative lateral wall fracture is the main determinant of stability in these fractures. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Caprock integrity susceptibility to permeable fracture creation

    DOE PAGES

    Frash, Luke; Carey, James William; Ickes, Timothy Lee; ...

    2017-07-14

    Caprock leakage is of crucial concern for environmentally and economically sustainable development of carbon dioxide sequestration and utilization operations. One potential leakage pathway is through fractures or faults that penetrate the caprock. In this study, we investigate the permeability induced by fracturing initially intact Marcellus shale outcrop specimens at stressed conditions using a triaxial direct-shear method. Measurements of induced permeability, fracture geometry, displacement, and applied stresses were all obtained at stressed conditions to investigate the coupled processes of fracturing and fluid flow as may occur in the subsurface. Fracture geometry was directly observed at stressed conditions using X-ray radiography video.more » Numerical simulation was performed to evaluate the stress distribution developed in the experiments. Our experiments show that permeability induced by fracturing is strongly dependent on the stresses at which the fractures are created, the magnitude of shearing displacement, and the duration of flow. The strongest permeability contrast was observed when comparing specimens fractured at low stress to others fractured at higher stress. Measureable fracture permeability decreased by up to 7 orders of magnitude over a corresponding triaxial confining stress range of 3.5 MPa to 30 MPa. These results show that increasing stress, depth, and time are all significant permeability inhibitors that may limit potential leakage through fractured caprock.« less

  20. Caprock integrity susceptibility to permeable fracture creation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frash, Luke; Carey, James William; Ickes, Timothy Lee

    Caprock leakage is of crucial concern for environmentally and economically sustainable development of carbon dioxide sequestration and utilization operations. One potential leakage pathway is through fractures or faults that penetrate the caprock. In this study, we investigate the permeability induced by fracturing initially intact Marcellus shale outcrop specimens at stressed conditions using a triaxial direct-shear method. Measurements of induced permeability, fracture geometry, displacement, and applied stresses were all obtained at stressed conditions to investigate the coupled processes of fracturing and fluid flow as may occur in the subsurface. Fracture geometry was directly observed at stressed conditions using X-ray radiography video.more » Numerical simulation was performed to evaluate the stress distribution developed in the experiments. Our experiments show that permeability induced by fracturing is strongly dependent on the stresses at which the fractures are created, the magnitude of shearing displacement, and the duration of flow. The strongest permeability contrast was observed when comparing specimens fractured at low stress to others fractured at higher stress. Measureable fracture permeability decreased by up to 7 orders of magnitude over a corresponding triaxial confining stress range of 3.5 MPa to 30 MPa. These results show that increasing stress, depth, and time are all significant permeability inhibitors that may limit potential leakage through fractured caprock.« less

  1. Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children.

    PubMed

    Rizk, Ahmed Shawkat

    2015-06-01

    Supracondylar humeral fractures are one of the most common skeletal injuries in children. In cases of displacement and instability, the standard procedure is early closed reduction and percutaneous Kirschner wire fixation. However, between 10 and 20 % of patients present late. According to the literature, patients with neglected fractures are those patients who presented for treatment after 14 days of injury. The delay is either due to lack of medical facilities or social and financial constraints. The neglected cases are often closed injuries with no vascular compromise. However, the elbow may still be tense and swollen with abrasions or crusts. In neglected cases, especially after early appearance of callus, there is no place for closed reduction and percutaneous pinning. Traditionally, distal humeral fractures have been managed with surgical approaches that disrupt the extensor mechanism with less satisfactory functional outcome due to triceps weakness and elbow stiffness. The aim of this study is to evaluate the outcome of delayed open reduction using the triceps-sparing approach and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in children. This prospective study included 15 children who had neglected displaced supracondylar and distal humeral fractures. All patients were completely evaluated clinically and radiologically before intervention, after surgery and during the follow-up. The follow-up period ranged from 8 to 49 months, with a mean period of 17 months. Functional outcome was evaluated according to the Mayo Elbow Performance Index (MEPI) and Mark functional criteria. All fractures united in a mean duration of 7.2 weeks (range 5-10 weeks) with no secondary displacement or mal-union. Excellent results were found at the last follow-up in 13 of the 15 patients studied (86.66 %), while good results were found in two patients (13.33 %) according to the MEPI scale. According to the Mark functional criteria, there was one patient with a fair result (6.66 %). The results were very satisfactory if compared with traditional operative techniques, with many advantages including anatomical reduction and fixation of the fractures, avoidance of ulnar nerve injury, preservation of the extensor mechanism, decrease in incidence of myositis ossificans around the elbow and decrease in post-operative stiffness. IV.

  2. Molecular-dynamics Simulation-based Cohesive Zone Representation of Intergranular Fracture Processes in Aluminum

    NASA Technical Reports Server (NTRS)

    Yamakov, Vesselin I.; Saether, Erik; Phillips, Dawn R.; Glaessgen, Edward H.

    2006-01-01

    A traction-displacement relationship that may be embedded into a cohesive zone model for microscale problems of intergranular fracture is extracted from atomistic molecular-dynamics simulations. A molecular-dynamics model for crack propagation under steady-state conditions is developed to analyze intergranular fracture along a flat 99 [1 1 0] symmetric tilt grain boundary in aluminum. Under hydrostatic tensile load, the simulation reveals asymmetric crack propagation in the two opposite directions along the grain boundary. In one direction, the crack propagates in a brittle manner by cleavage with very little or no dislocation emission, and in the other direction, the propagation is ductile through the mechanism of deformation twinning. This behavior is consistent with the Rice criterion for cleavage vs. dislocation blunting transition at the crack tip. The preference for twinning to dislocation slip is in agreement with the predictions of the Tadmor and Hai criterion. A comparison with finite element calculations shows that while the stress field around the brittle crack tip follows the expected elastic solution for the given boundary conditions of the model, the stress field around the twinning crack tip has a strong plastic contribution. Through the definition of a Cohesive-Zone-Volume-Element an atomistic analog to a continuum cohesive zone model element - the results from the molecular-dynamics simulation are recast to obtain an average continuum traction-displacement relationship to represent cohesive zone interaction along a characteristic length of the grain boundary interface for the cases of ductile and brittle decohesion. Keywords: Crack-tip plasticity; Cohesive zone model; Grain boundary decohesion; Intergranular fracture; Molecular-dynamics simulation

  3. Adolescent clavicle nonunions: potential risk factors and surgical management.

    PubMed

    Pennock, Andrew T; Edmonds, Eric W; Bae, Donald S; Kocher, Mininder S; Li, Ying; Farley, Frances A; Ellis, Henry B; Wilson, Philip L; Nepple, Jeffrey; Gordon, J Eric; Willimon, Samuel C; Busch, Michael T; Spence, David D; Kelly, Derek M; Pandya, Nirav K; Sabatini, Coleen S; Shea, Kevin G; Heyworth, Benton E

    2018-01-01

    Clavicle nonunions in adolescent patients are exceedingly rare. The purpose of this study was to evaluate a series of clavicle nonunions from a pediatric multicenter study group to assess potential risk factors and treatment outcomes. A retrospective review of all clavicle nonunions in patients younger than 19 years was performed at 9 pediatric hospitals between 2006 and 2016. Demographic and surgical data were documented. Radiographs were evaluated for initial fracture classification, displacement, shortening, angulation, and nonunion type. Clinical outcomes were evaluated, including rate of healing, time to union, return to sports, and complications. Risk factors for nonunion were assessed by comparing the study cohort with a separate cohort of age-matched patients with a diaphyseal clavicle fracture. There were 25 nonunions (mean age, 14.5 years; range, 10.0-18.9 years) identified, all of which underwent surgical fixation. Most fractures were completely displaced (68%) initially, but 21% were partially displaced and 11% were nondisplaced. Bone grafting was performed in 24 of 25 cases, typically using the hypertrophic callus. Radiographic healing was achieved in 96% of cases. One patient (4%) required 2 additional procedures to achieve union. The primary risk factor for development of a nonunion was a previous history of an ipsilateral clavicle fracture. Clavicle nonunions can occur in the adolescent population but are an uncommon clinical entity. The majority occur in male patients with displaced fractures, many of whom have sustained previous fractures of the same clavicle. High rates of union were achieved with plate fixation and the use of bone graft. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Variation in Treatment of Displaced Geriatric Acetabular Fractures Among 15 Level-I Trauma Centers.

    PubMed

    Manson, Theodore T; Reider, Lisa; OʼToole, Robert V; Scharfstein, Daniel O; Tornetta, Paul; Gary, Joshua L

    2016-09-01

    To document the initial treatment of displaced acetabular fractures among older adults across multiple trauma centers and to investigate the factors that influence the decision to operate and the choice of operative procedure [open reduction internal fixation (ORIF) vs. total hip arthroplasty (THA)]. Retrospective observational study. Fifteen US level-I trauma centers participating in the Major Extremity Trauma Research Consortium. Overall, 269 patients aged 60 years or older admitted for the treatment of a displaced acetabular fracture. None. Treatment. Sixty percent of fractures (n = 162) were treated operatively. Younger age (<80 years), injury from high-energy mechanism, fractures with femoral head impaction, and fractures without hip congruency were significantly associated with receiving operative treatment (P < 0.05). Significant site variation in operative versus nonoperative treatment occurred even after accounting for these factors (P = 0.0044). Among operatively treated patients, 88% (n = 142) received ORIF and 12% (n = 20) received THA as the initial treatment. Women were more likely to be treated with initial THA compared with men; of the known risk factors for poor outcomes with ORIF (ie, dome or roof impaction, femoral head impaction, or posterior wall involvement), only dome impaction was significantly associated with receiving initial THA (P < 0.05). Currently, no treatment guidelines exist for acetabular fractures in older adults, which likely explains the significant site variation in operative versus nonoperative treatment. This study identifies patient and injury factors that drive treatment decisions, which will be important in planning and designing future trials needed to determine the best treatment for these fractures.

  5. The Role of a Conservative Minimal Interventional Management Protocol in the Fractures of the Dentate Portion of the Adult Mandible

    PubMed Central

    Krishnan, Balasubramanian

    2015-01-01

    Mandibular fractures are commonly encountered by the maxillofacial surgeon. Maxillomandibular fixation (MMF) and open reduction and internal fixation (ORIF), or a combination of both, are the accepted standard treatments. This study aims to assess the role of a conservative minimal intervention protocol in the management of undisplaced/minimally displaced fractures of the dentate portion of the adult mandible and the complications associated with such minimalistic intervention. Thirty-four patients with undisplaced/minimally displaced fractures of the dentate portion of the adult mandible were advised to restrict mouth opening and limit themselves to a soft diet for a minimum of 4 weeks. All patients were advised follow-up at regular intervals for at least 3 months. Five patients were lost to follow-up. Symphysis and parasymphysis fractures were the most common fracture locations. Fourteen patients needed tension band stabilization with a mandibular arch bar/bridle wiring and three patients required extraction of luxated teeth. All patients showed satisfactory healing except three in whom additional intervention (ORIF) was performed. The improvement in mouth opening was statistically significant. Complications were seen more frequently among smokers and alcoholics. For patients with minimally displaced mandibular fractures, it is necessary to consider if the perceived benefits of intervention justify the associated added costs and possible complications. Patients have to be fully informed about the possible complications while using this minimal intervention protocol. This study concludes that a conservative minimal intervention management protocol for such fractures of the dentate portion of the mandible can produce satisfactory results. PMID:26889344

  6. Primary total hip arthroplasty versus hemiarthroplasty for displaced intracapsular hip fractures in older patients: systematic review.

    PubMed

    Hopley, Colin; Stengel, Dirk; Ekkernkamp, Axel; Wich, Michael

    2010-06-11

    To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.

  7. Modified Essex-Lopresti / Westheus reduction for displaced intra-articular fractures of the calcaneus. Description of surgical technique and early outcomes.

    PubMed

    Pillai, Anand; Basappa, Prabhudeva; Ehrendorfer, Stefan

    2007-02-01

    We describe a modification of the classical Essex-Lopresti manoeuvre for the indirect reduction and stabilisation of displaced intra-articular fractures of the calcaneus. The radiological and functional results achieved using this technique in 15 patients is presented. Ten tongue-shaped and 8 joint depression type fractures were treated by the new method, incorporating the use of an additional traction pin. The pre and postoperative Böhler angles as well as the correction achieved were documented. Functional assessment was carried out using the Maryland Foot Score. The mean pre-operative Böhler angle in the joint depression group was 5.5 degrees, and in the tongue shaped fracture group 5 degrees. The mean postoperative Böhler angle in the joint depression group was 15.8 degrees, and in the tongue shape group was 23.25 degrees. At a mean follow-up of 28 months the joint depression group scored 51/100 on the foot score, and the tongue shaped fracture group 77/100. The mean correction achieved as well as the mean overall functional scores were significantly better in the tongue shaped group. The technique described has much promise in the management of selected displaced intra-articular fractures of the calcaneus (true tongue shaped / Sanders II), and may also have a limited role in other fracture types in patients with significant co-morbidities, soft tissue compromise and poor healing potential.

  8. Does C₁ fracture displacement correlate with transverse ligament integrity?

    PubMed

    Radcliff, Kristen E; Sonagli, Marcos A; Rodrigues, Luciano M; Sidhu, Gursukhman S; Albert, Todd J; Vaccaro, Alexander R

    2013-05-01

    The Rule of Spence states that displacement of the C₁ lateral masses by >6.9-8.1 mm suggests loss of transverse ligament integrity. The purpose of this study was to establish the thresholds of C₁ displacement on CT scans that correspond to transverse ligament disruption. Over four years, consecutive patients with acute C₁ fractures with at least three fracture lines were analyzed. CT measurements and MRI were assessed by blinded observers for bony displacement in the axial (internal and external lateral mass separation), coronal and sagittal planes and transverse ligament integrity. Eighteen patients were studied. Mean CT bony measurements were as follows: internal border lateral mass separation (ILM) 23.3 ± 3.4 mm, external border lateral mass separation (ELM) 50.3 ± 4.3 mm, total C₁ lateral mass overhang over the C₂ superior process (LMO) 5.4 ± 1.3 mm. Twelve patients were identified as having intact transverse ligament and six had transverse ligament disruption. There was no difference in mean normalized ILM, ELM, or LMO between patients with or without transverse ligament integrity (P > 0.05). There was no correlation between bony displacement and transverse ligament integrity. CT scans post-injury may not show the position of maximal displacement. If there is clinical concern about a possible transverse ligament injury, MRI should be performed. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  9. The floating shoulder.

    PubMed

    Owens, B D; Goss, T P

    2006-11-01

    The floating shoulder is defined as ipsilateral fractures of the midshaft of the clavicle and the neck of the glenoid. This rare injury can be difficult to manage without a thorough understanding of the complex anatomy of the shoulder girdle. Surgical intervention needs to be considered for all of these injuries. While acceptable results can be expected with non-operative management of minimally-displaced fractures, displacement at one or both sites is best managed with surgical reduction and fixation.

  10. Definition of Mutually Optimum NDI and Proof Test Criteria for 2219 Aluminum Pressure Vessels. Volume 2: Optimization and Fracture Studies

    NASA Technical Reports Server (NTRS)

    Schwartzberg, F. R.; Toth, C., Jr.; King, R. G.; Todd, P. H., Jr.

    1979-01-01

    Certain behavioral aspects associated with fracture and crack extension that cannot be studied using other techniques were evaluated with the ultrasonic method. Characterization of collimated beam techniques showed that significant beam width reduction could be accomplished. Techniques for collimation are given. The crack-opening displacement-gage correction-factor study showed that displacement resulting from crack opening and that from plasticity could be readily differentiated. Crack closure studies using both ultrasonic and crack-opening displacement measurements showed an opening and closing behavior associated with load-unload curves. The results of this work were in general agreement with the closure concepts of Elber. Ultrasonic measurements used to study the nature of flaw extension characteristics associated with failure of the ligament between the flaw front and back surface showed that penetration could occur by an abrupt fracturing after subcritical growth or by continuous growth.

  11. Displaced Proximal Humerus Fractures: is a Sling as Good as a Plate?

    PubMed

    Steinhaus, Michael E; Dare, David M; Gulotta, Lawrence V

    2016-10-01

    The treatment of displaced proximal humerus fractures is challenging and complex, as its success is predicated on multiple factors. While it is clear that a majority of proximal humerus fractures may be treated nonoperatively, it is less clear which patients benefit from surgical management. The PROFHER trial, a randomized controlled study, used patient-reported outcomes to compare surgical to nonsurgical management of displaced proximal humerus fractures. The purpose of this review is to highlight the strengths and weaknesses of the PROFHER trial and to assess the validity of its conclusion in the context of existing literature. The authors found no difference in the Oxford Shoulder Score (OSS) between the surgical and nonsurgical groups. Additionally, no difference was found between groups in any of the secondary outcomes, which included the Short-Form 12 (SF-12) health survey, surgical and fracture-related complications, additional surgery or therapy, inpatient medical complications, and mortality. They concluded that the recent increase in surgical management of proximal humerus fractures is perhaps unwarranted. While the randomization was successful and the pragmatic design may enable greater generalizability, this study possesses numerous flaws inherent in such an ambitious endeavor, including an inability to identify specific factors which explain the lack of superiority of surgical management. Despite its weaknesses, this study is a valuable datapoint which encourages surgeons to reexamine their surgical indications for this injury.

  12. Cubic law with aperture-length correlation: implications for network scale fluid flow

    NASA Astrophysics Data System (ADS)

    Klimczak, Christian; Schultz, Richard A.; Parashar, Rishi; Reeves, Donald M.

    2010-06-01

    Previous studies have computed and modeled fluid flow through fractured rock with the parallel plate approach where the volumetric flow per unit width normal to the direction of flow is proportional to the cubed aperture between the plates, referred to as the traditional cubic law. When combined with the square root relationship of displacement to length scaling of opening-mode fractures, total flow rates through natural opening-mode fractures are found to be proportional to apertures to the fifth power. This new relationship was explored by examining a suite of flow simulations through fracture networks using the discrete fracture network model (DFN). Flow was modeled through fracture networks with the same spatial distribution of fractures for both correlated and uncorrelated fracture length-to-aperture relationships. Results indicate that flow rates are significantly higher for correlated DFNs. Furthermore, the length-to-aperture relations lead to power-law distributions of network hydraulic conductivity which greatly influence equivalent permeability tensor values. These results confirm the importance of the correlated square root relationship of displacement to length scaling for total flow through natural opening-mode fractures and, hence, emphasize the role of these correlations for flow modeling.

  13. Investigation of flaw geometry and loading effects on plane strain fracture in metallic structures

    NASA Technical Reports Server (NTRS)

    Hall, L. R.; Finger, R. W.

    1971-01-01

    The effects on fracture and flaw growth of weld-induced residual stresses, combined bending and tension stresses, and stress fields adjacent to circular holes in 2219-T87 aluminum and 5AI-2.5Sn(ELI) titanium alloys were evaluated. Static fracture tests were conducted in liquid nitrogen; fatigue tests were performed in room air, liquid nitrogen, and liquid hydrogen. Evaluation of results was based on linear elastic fracture mechanics concepts and was directed to improving existing methods of estimating minimum fracture strength and fatigue lives for pressurized structure in spacecraft and booster systems. Effects of specimen design in plane-strain fracture toughness testing were investigated. Four different specimen types were tested in room air, liquid nitrogen and liquid hydrogen environments using the aluminum and titanium alloys. Interferometry and holograph were used to measure crack-opening displacements in surface-flawed plexiglass test specimens. Comparisons were made between stress intensities calculated using displacement measurements, and approximate analytical solutions.

  14. A transient fault-valve mechanism operating in upper crustal level, Sierras Pampeanas, Argentina

    NASA Astrophysics Data System (ADS)

    Japas, María Silvia; Urbina, Nilda Esther; Sruoga, Patricia; Garro, José Matías; Ibañes, Oscar

    2016-11-01

    Located in the Sierras Pampeanas (the broken-foreland of the Pampean flat slab segment in the southern Central Andes), the Cerro Tiporco volcanic field shows Neogene hydrothermal activity linked to migration of arc-magmatism into the foreland. Late Neogene deposits comprise epithermal vein systems emplaced in Precambrian-Early Palaeozoic igneous-metamorphic basement, Late Miocene sedimentary rocks and Early Pliocene volcaniclastic rocks. Mineralization consists of calcareous onyx, aragonite and calcite veins as well as travertine deposits. Onyx and aragonite occur as fill of low-displacement nearly vertical reverse-sinistral faults striking NW, and nearly horizontal dilatant fractures. The latter consist of load-removal induced fractures affecting the igneous-metamorphic rocks, as well as bedding planes in the Late Miocene sediments. The presence of veins recording multiple fracture episodes and crack-and-seal growth of veins suggests relatively low differential stress and supralithostatic fluid pressure, as well as cyclic changes in pore pressure and high mineral-deposition/fracture-opening ratio. These conditions support a mechanism of fault-valve behaviour during onyx and aragonite vein emplacement. The fault-valve mechanism involves fractures associated with impermeable barriers between environments with different fluid pressure. Faulting generated an appreciable directional permeability triggering fluid migration from the highest to the lowest pressure region, with subsequent deposition and sealing that started a new pressurization-faulting-sealing cycle. Late aragonite and calcite veins suggest a change in kinematics indicating the onset of tectonic-load conditions.

  15. Complications in the treatment of adolescent clavicle fractures.

    PubMed

    Luo, T David; Ashraf, Ali; Larson, A Noelle; Stans, Anthony A; Shaughnessy, William J; McIntosh, Amy L

    2015-04-01

    This study evaluated the complications associated with the treatment of clavicle fractures in adolescents. All cases of clavicle fractures were identified during an 8-year period between January 2005 and January 2013. During the study period, 153 clavicle fractures occurred in patients between the ages of 14 and 17 years who were treated at the authors' center. Medical records and radiographs were reviewed to determine injury mechanism, fracture pattern, treatment, and complications. Injury severity was assessed as high, medium, and low. Patients with medial or distal metaphyseal fractures and intra-articular fractures were excluded. Of the 153 clavicle fractures, 23 (15.0%) were treated surgically. Compared with the fractures treated nonsurgically, the surgical fractures had greater shortening (mean, 2.0 vs 0.9 cm; P<.001) and were more likely to be comminuted (65.2% vs 23.1%; P<.001). Complications occurred in 21.7% of fractures treated surgically, including refracture (n=2), implant removal for prominence (n=2), and nonunion with implant failure (n=1). One complication was associated with intramedullary nailing, whereas the other 4 complications occurred in clavicles treated with plate fixation. In the non-surgical group, no patients sustained a refracture or malunion who required delayed surgical intervention. Pediatric fellowship-trained orthopedic surgeons treated 78 displaced fractures, resulting in 8 (10.3%) surgeries. Nonpediatric orthopedic specialists treated 46 displaced fractures, 15 (32.6%) of which were treated surgically (P=.0035). Copyright 2015, SLACK Incorporated.

  16. Multifocal humeral fractures.

    PubMed

    Maresca, A; Pascarella, R; Bettuzzi, C; Amendola, L; Politano, R; Fantasia, R; Del Torto, M

    2014-02-01

    Multifocal humeral fractures are extremely rare. These may affect the neck and the shaft, the shaft alone, or the diaphysis and the distal humerus. There is no classification of these fractures in the literature. From 2004 to 2010, 717 patients with humeral fracture were treated surgically at our department. Thirty-five patients presented with an associated fracture of the proximal and diaphyseal humerus: synthesis was performed with plate and screws in 34 patients, and the remaining patient had an open fracture that was treated with an external fixator. Mean follow-up was 3 years and 3 months. A classification is proposed in which type A fractures are those affecting the proximal and the humeral shaft, type B the diaphysis alone, and type C the diaphysis in association with the distal humerus. Type A fractures are then divided into three subgroups: A-I, undisplaced fracture of the proximal humerus and displaced shaft fracture; A-II: displaced fracture of the proximal and humeral shaft; and A-III: multifragmentary fracture affecting the proximal humerus and extending to the diaphysis. Multifocal humeral fractures are very rare and little described in the literature, both for classification and treatment. The AO classification describes bifocal fracture of the humeral diaphysis, type B and C. The classification suggested in this article mainly concerns fractures involving the proximal and humeral shaft. A simple classification of multifocal fractures is suggested to help the surgeon choose the most suitable type of synthesis for surgical treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Instability in Immiscible Fluids Displacement from Cracks and Porous Samples

    NASA Astrophysics Data System (ADS)

    Smirnov, N. N.; Nikitin, V. F.; Ivashnyov, O. E.

    2002-01-01

    problems of terrestrial engineering and technology. Surface tension affected flows in porous media could be much better understood in microgravity studies eliminating the masking effects of gravity. Saffman-Taylor instability of the interface could bring to formation and growth of "fingers" of gas penetrating the bulk fluid. The growth of fingers and their further coalescence could not be described by the linear analysis. Growth of fingers causes irregularity of the mixing zone. The tangential velocity difference on the interface separating fluids of different densities and viscousities could bring to a Kelvin-Helmholtz instability resulting in "diffusion of fingers" partial regularization of the displacement mixing zone. Thus combination of the two effects would govern the flow in the displacement process. fracture under a pressure differential displacing the high viscosity residual fracturing fluid. There are inherent instability and scalability problems associated with viscous fingering that play a key role in the cleanup procedure. Entrapment of residual fracturing fluid by the gas flow lowers down the quality of a fracture treatment leaving most of fluid in the hydraulic fracture thus decreasing the production rate. The gravity effects could play essential role in vertical hydraulic fractures as the problem is scale dependent. displacement of viscous fluid by a less viscous one in a two-dimensional channel with vertical breaks, and to determine characteristic size of entrapment zones. Extensive direct numerical simulations allow to investigate the sensitivity of the displacement process to variation of values of the main governing parameters. were found for the two limiting cases: infinitely wide cell, and narrow cell with an infinitely small gap between the finger and the side walls. governing parameters. The obtained solutions allowed to explain the physical meaning of the exiting empirical criteria for the beginning of viscous fingering and the growth of a number of fingers in the cell, and allowed us to make some additional suggestions for the cleanup procedure. depending on the resident fluid properties, for which the displacement still remains stable. viscous one were carried out. Validation of the code was performed by comparing the results of model problems simulations with the existing solutions published in literature. Being in a good agreement with the previously obtained results, nevertheless, the developed code is an advanced one. While the existing codes could operate with linear equations and regular geometry and initial disturbances only, the new code permits taking into account non-linear effects as well. characterizing the quality of displacement. The functional dependence of the dimensionless criteria on the values of governing parameters needs further investigations. Services, an international company in the oil and gas industry.

  18. Failure in lithium-ion batteries under transverse indentation loading

    NASA Astrophysics Data System (ADS)

    Chung, Seung Hyun; Tancogne-Dejean, Thomas; Zhu, Juner; Luo, Hailing; Wierzbicki, Tomasz

    2018-06-01

    Deformation and failure of constrained cells and modules in the battery pack under transverse loading is one of the most common conditions in batteries subjected to mechanical impacts. A combined experimental, numerical and analytical approach was undertaken to reveal the underlying mechanism and develop a new cell failure model. When large format pouch cells were subjected to local indentation all the way to failure, the post-mortem examination of the failure zones beneath the punches indicates a consistent slant fracture surface angle to the battery plane. This type of behavior can be described by the critical fracture plane theory in which fracture is caused by the shear stress modified by the normal stress. The Mohr-Coulomb fracture criterion is then postulated and it is shown how the two material constants can be determined from just one indentation test. The orientation of the fracture plane is invariant with respect to the type of loading and can be considered as a property of the cell stack. In addition, closed-form solutions are derived for the load-displacement relation for both plane-strain and axisymmetric cases. The results are in good agreement with the numerical simulation of the homogenized model and experimentally measured responses.

  19. Effect of Control Mode and Test Rate on the Measured Fracture Toughness of Advanced Ceramics

    NASA Technical Reports Server (NTRS)

    Hausmann, Bronson D.; Salem, Jonathan A.

    2018-01-01

    The effects of control mode and test rate on the measured fracture toughness of ceramics were evaluated by using chevron-notched flexure specimens in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% (statistically insignificant) variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or crack mouth opening displacement (CMOD) control gave approx. 5% (statistically significant) variation over a very wide range of rates (1 to 80 µm/m/s), with the measurements being a function of rate. However, the rate effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of a nitrogen environment during strain controlled tests, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micons/m/s). CMOD or strain control did allow stable crack extension well past maximum force, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM Test Method C1421 on fracture toughness measurement.

  20. [Operative treatment of displaced intra-articular calcaneal fractures].

    PubMed

    Zwipp, H; Rammelt, S; Amlang, M; Pompach, M; Dürr, C

    2013-12-01

    Anatomic reduction of displaced intra-articular calcaneal fractures with restoration of height, length, and axial alignment and reconstruction of the subtalar and calcaneocuboid joints. Displaced intra-articular calcaneal fractures with incongruity of the posterior facet of the subtalar joint, loss of height, and axial malalignment. High perioperative risk, soft tissue infection, advanced peripheral arterial disease (stage III), neurogenic osteoarthropathy, poor patient compliance (e. g., substance abuse). Extended lateral approach with the patient placed on the uninjured side. Reduction of the anatomic shape and joint surfaces according to the preoperative CT-based planning. Reduction of the medial wall and step-wise reconstruction of the posterior facet from medial to lateral. Reduction of the tuberosity and anterior process fragments to the posterior joint block and temporary fixation with Kirschner wires. Internal fixation with an anatomic lateral plate in a locking or nonlocking mode. Alternatively less invasive internal fixation with a calcaneus nail over a sinus tarsi approach for less severe fracture types. The lower leg is immobilized in a brace until the wound is healed. Range of motion exercises of the ankle and subtalar joints are initiated on the second postoperative day. Patients are mobilized in their own shoe with partial weight bearing of 20 kg for 6-12 weeks depending on fracture severity and bone quality. Over a 4-year period, 163 patients with 184 displaced, intra-articular calcaneal fractures were treated with a lateral plate via an extended approach. In all, 102 patients with 116 fractures were followed for a mean of 8 years. A surgical revision was necessary in 4 cases (3.4%) of postoperative hematoma, 2 (1.7%) superficial and 5 (4.3%) deep infections. Of the latter, 2 patients needed a free flap for definite wound coverage, no calcanectomy or amputation was needed. Secondary subtalar fusion for symptomatic posttraumatic arthritis was performed in 9 cases (7.8%). At follow-up, the AOFAS Ankle/Hindfoot Score averaged 70.2, the Zwipp Score averaged 76.0, the German versions of the Foot Function Index and SF-36 physical component averaged 32.8 and 42.2, respectively. Scores were significantly lower with increasing fracture severity according to the Sanders and Zwipp classifications, bilateral fractures, open fractures, and with work-related injuries. With less invasive fixation using a calcaneal nail, superficial wound edge necrosis was seen in 2 of 75 cases (2.7%).

  1. A randomized controlled trial of nonoperative treatment versus open reduction and internal fixation for stable, displaced, partial articular fractures of the radial head: the RAMBO trial

    PubMed Central

    2014-01-01

    Background The choice between operative or nonoperative treatment is questioned for partial articular fractures of the radial head that have at least 2 millimeters of articular step-off on at least one radiograph (defined as displaced), but less than 2 millimeter of gap between the fragments (defined as stable) and that are not associated with an elbow dislocation, interosseous ligament injury, or other fractures. These kinds of fractures are often classified as Mason type-2 fractures. Retrospective comparative studies suggest that operative treatment might be better than nonoperative treatment, but the long-term results of nonoperative treatment are very good. Most experts agree that problems like reduced range of motion, painful crepitation, nonunion or bony ankylosis are infrequent with both nonoperative and operative treatment of an isolated displaced partial articular fracture of the radial head, but determining which patients will have problems is difficult. A prospective, randomized comparison would help minimize bias and determine the balance between operative and nonoperative risks and benefits. Methods/Design The RAMBO trial (Radial Head – Amsterdam – Amphia – Boston - Others) is an international prospective, randomized, multicenter trial. The primary objective of this study is to compare patient related outcome defined by the ‘Disabilities of Arm, Shoulder and Hand (DASH) score’ twelve months after injury between operative and nonoperative treated patients. Adult patients with partial articular fractures of the radial head that comprise at least 1/3rd of the articular surface, have ≥ 2 millimeters of articular step-off but less than 2 millimeter of gap between the fragments will be enrolled. Secondary outcome measures will be the Mayo Elbow Performance Index (MEPI), the Oxford Elbow Score (OES), pain intensity through the ‘Numeric Rating Scale’, range of motion (flexion arc and rotational arc), radiographic appearance of the fracture (heterotopic ossification, radiocapitellar and ulnohumeral arthrosis, fracture healing, and signs of implant loosening or breakage) and adverse events (infection, nerve injury, secondary interventions) after one year. Discussion The successful completion of this trial will provide evidence on the best treatment for stable, displaced, partial articular fractures of the radial head. Trial registration The trial is registered at the Dutch Trial Register: NTR3413. PMID:24885637

  2. Concomitant intra-articular glenohumeral injuries in displaced fractures of the lateral clavicle.

    PubMed

    Beirer, Marc; Zyskowski, Michael; Crönlein, Moritz; Pförringer, Dominik; Schmitt-Sody, Marcus; Sandmann, Gunther; Huber-Wagner, Stefan; Biberthaler, Peter; Kirchhoff, Chlodwig

    2017-10-01

    To detect concomitant intra-articular glenohumeral injuries, in acute displaced fractures of the lateral clavicle, initially missed due to unfeasible clinical evaluation of the acutely injured shoulder. All patients suffering from an acute displaced lateral clavicle fracture with indication to surgical treatment underwent diagnostic shoulder arthroscopy prior to open reduction and internal fixation. In case of therapy-relevant intra-articular glenohumeral injuries, subsequent surgical treatment was performed. Intra-articular injuries were found in 13 of 28 patients (46.4 %) with initially suspected isolated lateral clavicle fracture. Additional surgical treatment was performed in 8 of 28 cases (28.6 %). Superior labral anterior-posterior (SLAP) lesions were observed in 4 of 28 patients (14.3 %; SLAP II a: 1; II b: 1; III: 1; and IV: 1). Lesions of the pulley system were found in 3 of 28 patients (10.7 %; Habermeyer III°). One partial articular supraspinatus tendon avulsion lesion (3.6 %) and one lesion of the subscapularis tendon (3.6 %; Fox and Romeo II°) were observed. Traumatic concomitant glenohumeral injuries in lateral clavicle fractures seem to be more frequent than expected in general. Subsequent surgical treatment of these formerly missed but therapy-relevant injuries may increase functional outcome and reduce complication rate. IV.

  3. A novel ex vivo model of compressive immature rib fractures at pathophysiological rates of loading.

    PubMed

    Beadle, Nicola; Burnett, Timothy L; Hoyland, Judith A; Sherratt, Michael J; Freemont, Anthony J

    2015-11-01

    Compressive rib fractures are considered to be indicative of non-accidental injury (NAI) in infants, which is a significant and growing issue worldwide. The diagnosis of NAI is often disputed in a legal setting, and as a consequence there is a need to model such injuries ex vivo in order to characterise the forces required to produce non-accidental rib fractures. However, current models are limited by type of sample, loading method and rate of loading. Here, we aimed to: i) develop a loading system for inducing compressive fractures in whole immature ribs that is more representative of the physiological conditions and mechanism of injury employed in NAI and ii) assess the influence of loading rate and rib geometry on the mechanical performance of the tissue. Porcine ribs (5-6 weeks of age) from 12 animals (n=8 ribs/animal) were subjected to axial compressive load directed through the anterior-posterior rib axis at loading rates of 1, 30, 60 or 90 mm/s. Key mechanical parameters (including peak load, load and percentage deformation to failure and effective stiffness) were quantified from the load-displacement curves. Measurements of the rib length, thickness at midpoint, distance between anterior and posterior extremities, rib curvature and fracture location were determined from radiographs. This loading method typically produced incomplete fractures around the midpoint of the ribs, with 87% failing in this manner; higher loads and less deformation were required for ribs to completely fracture through both cortices. Loading rate, within the range of 1-90 mm/s, did not significantly affect any key mechanical parameters of the ribs. Load-displacement curves displaying characteristic and quantifiable features were produced for 90% of the ribs tested, and multiple regression analyses indicate that, in addition to the geometrical variables, there are other factors such as the micro- and nano-structure that influence the measured mechanical data. A reproducible method of inducing fractures in a consistent location in immature porcine ribs has been successfully developed. Fracture appearance may be indicative of the amount of load and deformation that produced the fracture, which is an important finding for NAI, where knowledge of the aetiology of fractures is vital. Characteristic rib behaviour independent of loading rate and, to an extent, rib geometry has been demonstrated, allowing further investigation into how the complex micro- and nano-structure of immature ribs influences the mechanical performance under compressive load. This research will ultimately enable improved characterisation of the loading pattern involved in non-accidental rib fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures.

    PubMed

    Wang, Chen; Xu, Gui-Jun; Han, Zhe; Jiang, Xuan; Zhang, Cheng-Bao; Dong, Qiang; Ma, Jian-Xiong; Ma, Xin-Long

    2015-11-01

    The aim of the study was to introduce a new method for measuring the residual displacement of the femoral head after internal fixation and explore the relationship between residual displacement and osteonecrosis with femoral head, and to evaluate the risk factors associated with osteonecrosis of the femoral head in patients with femoral neck fractures treated by closed reduction and percutaneous cannulated screw fixation.One hundred and fifty patients who sustained intracapsular femoral neck fractures between January 2011 and April 2013 were enrolled in the study. All were treated with closed reduction and percutaneous cannulated screw internal fixation. The residual displacement of the femoral head after surgery was measured by 3-dimensional reconstruction that evaluated the quality of the reduction. Other data that might affect prognosis were also obtained from outpatient follow-up, telephone calls, or case reviews. Multivariate logistic regression analysis was applied to assess the intrinsic relationship between the risk factors and the osteonecrosis of the femoral head.Osteonecrosis of the femoral head occurred in 27 patients (18%). Significant differences were observed regarding the residual displacement of the femoral head and the preoperative Garden classification. Moreover, we found more or less residual displacement of femoral head in all patients with high quality of reduction based on x-ray by the new technique. There was a close relationship between residual displacement and ONFH.There exists limitation to evaluate the quality of reduction by x-ray. Three-dimensional reconstruction and digital measurement, as a new method, is a more accurate method to assess the quality of reduction. Residual displacement of the femoral head and the preoperative Garden classification were risk factors for osteonecrosis of the femoral head. High-quality reduction was necessary to avoid complications.

  5. Trauma of facial skeleton in children: An indian perspective.

    PubMed

    Karim, Tanweer; Khan, Arshad Hafeez; Ahmed, Syed Saeed

    2010-06-01

    Both children and adults are subject to similar types of injuries but fractures of facial bones in children are relatively uncommon. The aim of this study was to evaluate the epidemiology of facial bone fractures among children of <12 years, their management and outcome in an Indian city. This retrospective study included children of <12 years of age with facial bone fractures admitted over a span of 3 years. In order to compare our results we reviewed the existing literature related to pediatric facial bone fractures. A total of 45 children were admitted for facial bone fractures. Forty (89%) of them were above 5 years of age and male to female ratio was 2:1. About 53.33% of these injuries were because of fall from height. Mandible fracture was the most common facial bone fracture among admitted patients. Symphysis and para-symphysis was the commonest site of mandibular fractures, seen in 49% cases. Majority of these fractures were managed by Inter-maxillary fixation and inter-osseous wiring. Mini-plates were used for widely displaced compound fractures. For un-displaced fractures observation alone was sufficient. Mandible is the commonest facial bone fracture in children, more often caused by accidental fall from height. The high osteogenic potential of pediatric mandible allows non-surgical management to be successful in an increased proportion of younger patients.

  6. Survey of Current Practice Patterns in the Management of Frontal Sinus Fractures

    PubMed Central

    Choi, Kevin J.; Chang, Bora; Woodard, Charles R.; Powers, David B.; Marcus, Jeffrey R.; Puscas, Liana

    2017-01-01

    The management of frontal sinus fractures has evolved in the endoscopic era. The development of functional endoscopic sinus surgery (FESS) has been incorporated into management algorithms proposed by otolaryngologists, but the extent of its influence on plastic surgeons and oral and maxillofacial surgeons is heretofore unknown. A cross-sectional survey was performed to assess the practice pattern variations in frontal sinus fracture management across multiple surgical disciplines. A total of 298 surveys were reviewed. 33.5% were facial plastic surgeons with otolaryngology training, 25.8% general otolaryngologists, 25.5% plastic surgeons, and 15.1% oral and maxillofacial surgeons. 74.8% of respondents practiced in an academic setting. 61.7% felt endoscopic sinus surgery changed their management of frontal sinus fractures. 91.8% of respondents favored observation for uncomplicated, nondisplaced frontal sinus outflow tract fractures. 36.4% favored observation and 35.9% favored endoscopic sinus surgery for uncomplicated, displaced frontal sinus outflow tract fractures. For complicated, displaced frontal sinus outflow tract fractures, obliteration was more frequently favored by plastic surgeons and oral and maxillofacial surgeons than those with otolaryngology training. The utility of FESS in managing frontal sinus fractures appears to be recognized across multiple surgical disciplines. PMID:28523084

  7. Minimally Displaced, Isolated Radial Head and Neck Fractures Do Not Require Formal Physical Therapy: Results of a Prospective Randomized Trial.

    PubMed

    Egol, Kenneth A; Haglin, Jack M; Lott, Ariana; Fisher, Nina; Konda, Sanjit R

    2018-04-18

    Nondisplaced and minimally displaced fractures of the radial head and neck are common injuries, yet the role of physical therapy (PT) in their treatment is unclear. The aim of this trial was to assess the need for formal PT following a simple fracture of the radial head or neck. Patients who had a nondisplaced or minimally displaced fracture of the radial head or neck and presented to 1 of 2 providers were enrolled prospectively between January 2014 and August 2016. Patients were randomized to receive outpatient PT or perform self-directed home exercise. The follow-up intervals were 6 weeks, 3 months, 6 months, and at least 1 year. The outcome measures were Disabilities of the Arm, Shoulder and Hand (DASH) scores; pain; time to clinical healing; and range of motion. Demographic data were analyzed using the Mann-Whitney U test and Fisher exact test. Independent-samples t tests were utilized to compare outcome measures. Fifty-one patients were enrolled in the study. The average follow-up was 16.6 months. Twenty-five patients were randomized to a home-exercise cohort, and 26 patients were randomized to a formal-outpatient-PT cohort. There were no significant differences in demographics between cohorts. At 6 weeks, the home-exercise cohort had better function as indicated by a significantly lower mean DASH score compared with the PT cohort (p = 0.021). At 3 months, 6 months, and final follow-up, there were no significant differences between cohorts for any outcome measure. Patients who performed home exercises after sustaining a nondisplaced or minimally displaced fracture of the radial head or neck demonstrated better early function at 6 weeks compared with patients who received formal PT. After 6 weeks, there were no significant differences in outcomes. These data suggest that prescribing PT for patients who have an isolated nondisplaced or minimally displaced fracture of the radial head or neck is not cost-effective and that instructing the patient to perform self-directed exercises will be followed by a similar outcome. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  8. Return to sports after plate fixation of displaced midshaft clavicular fractures in athletes.

    PubMed

    Ranalletta, Maximiliano; Rossi, Luciano A; Piuzzi, Nicolás S; Bertona, Agustin; Bongiovanni, Santiago L; Maignon, Gaston

    2015-03-01

    Recent prospective randomized trials support primary plate fixation of displaced midshaft clavicle fractures. However, the safety and efficacy of this practice have not been well documented in athletes, nor has the time to return-to-sport. To analyze the time to return-to-sport, functional outcomes, and complications in a group of athletes with displaced midshaft clavicle fractures treated using precontoured locking plates. Case series; Level of evidence, 4. A total of 54 athletes with displaced midshaft clavicle fractures were treated with plate fixation between November 1, 2008, and December 31, 2012. The mean follow-up time was 22.4 months. Patients completed a questionnaire focused on the time to return-to-sport and treatment course. Functional outcomes were assessed with the Constant score and short version of the Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire. Pain was evaluated with the visual analog scale (VAS). Radiographs were reviewed to identify radiographic union time, malunion, and nonunion. Of the 54 patients, 53 returned to sports after open reduction and internal fixation of their fracture; 94% returned to the same level. The mean time to return-to-sport was 68 days (range, 5-180 days). Nine (16.6%) of the cases returned to sports before 6 weeks after surgery, 40 (74%) returned between 6 and 12 weeks, and 5 patients (9.2%) returned 12 weeks after surgery. The mean Constant score was 94.1 ± 5.2 (range, 78-100), and the mean QuickDASH score was 0.4 ± 4.7 (range, 0-7.1). The mean VAS pain score during follow-up was 0.29 ± 1.0 (range, 0-5). Three major complications occurred: 1 extrinsic compression of the subclavian vein, 1 nonunion, and 1 hardware loosening. Hardware removal was necessary in 5 patients (9.3%). Plate fixation of displaced clavicle fractures in athletes is a safe procedure resulting in excellent functional outcomes, with an early return to the same level of sports in the majority of patients. © 2014 The Author(s).

  9. Effects of third fragment size and displacement on non-union of femoral shaft fractures after locking for intramedullary nailing.

    PubMed

    Lee, J R; Kim, H-J; Lee, K-B

    2016-04-01

    The femoral shaft fractures with large fragments makes anatomical reduction challenging and often results in non-union. In some studies, the degree of fragment displacement was reported to have affected non-union, but the association between the one fragment size and degree of displacement has not been fully clarified. Therefore we performed a retrospective study to assess: (1) the more influential factor of non-union: the degree of fragment displacement, or the fragment size? (2) the non-union rates according to different sizes and degrees of displacement. The degree of displacement is the more potent factor of non-union than the third fragment size in femoral shaft fractures. We assessed retrospectively 64 cases, which could be followed up for longer than one year. Fragments were divided according to the length of their long axis into three groups: group A (0-3.9cm), (n=21); group B (4-7.9cm), (n=22); group C (8cm or more), (n=21). Fragment displacement was also assessed in the proximal (P) or distal (D) end to the nearest cortex of the femoral shaft, and divided into the following groups: group P1 (n=44) or D1 (n=47), (0-9mm); group P2 (n=10) or D2 (n=11), (10-19mm); group P3 (n=7) or D3 (n=3), (20-29mm); and group P4 (n=3) or D4 (n=3), (30mm or more). The bone union rate was 86% in the small (less than 8cm) fragment groups and 71% in the large (8cm or more) fragment group (P=0.046). With respect to the degree of displacement, the union rate was lower (P=0.001) and the average union time was longer (P=0.012) in the 20mm or more group for both the proximal fragment part and the distal fragment part (P=0.002, P=0.014). A logistic regression analysis underlined the displacement in the proximal site (OR: 0.298, 95% CI: 0.118-0.750) as in the distal site (OR: 0.359, 95% CI: 0.162-0.793) as a larger effect on union rate than the fragment size that as no effect in logistic regression (OR 3.8, 95% CI: 0.669-21.6). Non-union develops significantly more frequently in femoral shaft fractures with fragments 8cm or longer or when the displacement in the proximal area is 20mm or greater and 10mm or greater in the distal area during the intramedullary nailing procedure. Regarding union rate, the degree of displacement has more influence than the third fragment size in femoral shaft fractures. IV, retrospective cohort study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Fracture of the manubrium with posterior displacement of the clavicle and first rib. A case report.

    PubMed

    Velutini, J A; Tarazona, P F

    1998-01-01

    This report describes a patient with a fracture of the manubrium of the sternum of a type which has not been reported previously. We discuss the incidence, the mechanism of production and the site of these fractures, and their treatment and prognosis.

  11. Bohler's angle's role in assessing the injury severity and functional outcome of internal fixation for displaced intra-articular calcaneal fractures: a retrospective study.

    PubMed

    Su, Yanling; Chen, Wei; Zhang, Tao; Wu, Xingwang; Wu, Zhanpo; Zhang, Yingze

    2013-09-24

    Controversy exits over the role of Böhler's angle in assessing the injury severity of displaced intra-articular calcaneal fractures and predicting the functional outcome following internal fixation. This study aims to investigate whether a correlation exists between Böhler's angle and the injury severity of displaced calcaneal fractures, and between surgical improvement of Böhler's angle and functional outcome. Patients treated operatively for unilateral closed displaced intra-articular calcaneal fractures from January 1, 2004 to March 31, 2008 were identified. The Böhler's angles of both calcaneus were measured, and the measurement of the uninjured foot was used as its normal control. The difference in the value of Böhler's angle measured preoperatively or postoperatively between the angle of the injured foot and that of the contralateral calcaneus were calculated, respectively. The change in Böhler's angle by ratio was calculated by dividing the difference value of Böhler's angle between bilateral calcaneus by its normal control. The injury severity was assessed according to Sanders classification. The functional outcomes were assessed using American Orthopaedic Foot & Ankle Society hindfoot scores. 274 patients were included into the study with a mean follow-up duration of 71 months. According to Sanders classification, the fracture pattern included 105 type II, 121 type III and 48 type IV fractures. According to American Orthopaedic Foot & Ankle Society hindfoot scoring system, the excellent, good, fair and poor results were achieved in 104, 132, 27, and 11 patients, respectively. The preoperative Böhler's angle, difference value of Böhler's angle between bilateral calcaneus, and change in Böhler's angle by ratio each has a significant correlation with Sanders classification (rs=-0.178, P=0.003; rs=-0.174, P=0.004; rs=-0.172, P=0.005, respectively), however, is not correlated with functional outcome individually. The three postoperative measurements were all found to have a significant correlation with American Orthopaedic Foot & Ankle Society hindfoot scores (rs=0.223, P<0.001; rs=0.224, P<0.001; rs=0.220, P<0.001, respectively). However, these correlations were all weak to low. There was a significant correlation between preoperative Böhler's angle and the injury severity of displaced intra-articular calcaneal fractures, but only postoperative Böhler's angle parameters were found to have a significant correlation with the functional recovery.

  12. Does fluoroscopy improve outcomes in paediatric forearm fracture reduction?

    PubMed

    Menachem, S; Sharfman, Z T; Perets, I; Arami, A; Eyal, G; Drexler, M; Chechik, O

    2016-06-01

    To compare the radiographic results of paediatric forearm fracture reduced with and without fluoroscopic enhancement to investigate whether fractures reduced under fluoroscopic guidance would have smaller residual deformities and lower rates of re-reduction and surgery. A retrospective cohort analysis was conducted comparing paediatric patients with acute forearm fracture in two trauma centres. Demographics and radiographic data from paediatric forearm fractures treated in Trauma Centre A with the aid of a C-arm fluoroscopy were compared to those treated without fluoroscopy in Trauma Centre B. Re-reduction, late displacement, post-reduction deformity, and need for surgical intervention were compared between the two groups. The cohort included 229 children (175 boys and 54 girls, mean age 9.41±3.2 years, range 1-16 years) with unilateral forearm fractures (83 manipulated with fluoroscopy and 146 without). Thirty-four (15%) children underwent re-reduction procedures in the emergency department. Fifty-three (23%) children had secondary displacement in the cast, of which 18 were operated on, 20 were re-manipulated, and the remaining 15 were kept in the cast with an acceptable deformity. Twenty-nine additional children underwent operation for reasons other than secondary displacement. There were no significant differences in re-reduction and surgery rates or in post-reduction deformities between the two groups. The use of fluoroscopy during reduction of forearm fractures in the paediatric population apparently does not have a significant effect on patient outcomes. Reductions performed without fluoroscopy were comparably accurate in correcting deformities in both coronal and sagittal planes. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.

    PubMed

    Nelson, Joshua D; McIff, Terence E; Moodie, Patrick G; Iverson, Jamey L; Horton, Greg A

    2010-03-01

    Internal fixation of the os calcis is often complicated by prolonged soft tissue management and posterior facet disruption. An ideal calcaneal construct would include minimal hardware prominence, sturdy posterior facet fixation and nominal soft tissue disruption. The purpose of this study was to develop such a construct and provide a biomechanical analysis comparing our technique to a standard internal fixation technique. Twenty fresh-frozen cadaver calcanei were used to create a reproducible Sanders type-IIB calcaneal fracture pattern. One calcaneus of each pair was randomly selected to be fixed using our compressive headless screw technique. The contralateral matched calcaneus was fixed with a nonlocking calcaneal plate in a traditional fashion. Each calcaneus was cyclically loaded at a frequency of 1 Hz for 4000 cycles using an increasing force from 250 N to 1000 N. An Optotrak motion capturing system was used to detect relative motion of the three fracture fragments at eight different points along the fracture lines. Horizontal separation and vertical displacement at the fracture lines was recorded, as well as relative rotation at the primary fracture line. When the data were averaged, there was more horizontal displacement at the primary fracture line of the plate and screw construct compared to the headless screw construct. The headless screw construct also had less vertical displacement at the primary fracture line at every load. On average those fractures fixed with the headless screw technique had less rotation than those fixed with the side plate technique. A new headless screw technique for calcaneus fracture fixation was shown to provide stability as good as, or better than, a standard side plating technique under the axial loading conditions of our model. Although further testing is needed, the stability of the proposed technique is similar to that typically provided by intramedullary fixation. This fixation technique provides a biomechanically stable construct with the potential for a minimally invasive approach and improved post-operative soft tissue healing.

  14. Measurement and interpretation of threshold stress intensity factors for steels in high-pressure hydrogen gas.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dadfarnia, Mohsen; Nibur, Kevin A.; San Marchi, Christopher W.

    2010-07-01

    Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} ismore » the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.« less

  15. Measurement and interpretation of threshold stress intensity factors for steels in high-pressure hydrogen gas.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nibur, Kevin A.

    2010-11-01

    Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} ismore » the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.« less

  16. Determinants of rib motion in flail chest.

    PubMed

    Cappello, M; Legrand, A; De Troyer, A

    1999-03-01

    We have previously developed a canine model of isolated flail chest to assess the effects of this condition on the mechanics of breathing, and these studies have led to the conclusion that the respiratory displacement of the fractured ribs is primarily determined by the fall in pleural pressure (Delta Ppl) and the action of the parasternal intercostal muscles. The present studies were designed to test the validity of this conclusion. A flail was induced in six supine anesthetized animals by fracturing both dorsally and ventrally the second to fifth ribs on the right side of the chest, after which the phrenic nerve roots were bilaterally sectioned in the neck. Sectioning the phrenic nerves caused a 34% decrease in Delta Ppl, associated with a 39% increase in parasternal intercostal inspiratory EMG activity (p < 0.05), and resulted in a marked reduction in the inspiratory inward displacement of the ribs. In three animals, the inward rib displacement was even reversed into a small outward displacement. When the airway was then occluded at end-expiration to increase Delta Ppl during the subsequent inspiration, all animals again showed a clear-cut inward rib displacement. These observations therefore confirm that in dogs with flail chest, the inspiratory displacement of the fractured ribs is set by the balance between the force related to pleural pressure and that generated by the parasternal intercostals. These observations also point to the critical importance of the pattern of inspiratory muscle activation in determining the magnitude of rib cage paradox in such patients.

  17. Haptic computer-assisted patient-specific preoperative planning for orthopedic fractures surgery.

    PubMed

    Kovler, I; Joskowicz, L; Weil, Y A; Khoury, A; Kronman, A; Mosheiff, R; Liebergall, M; Salavarrieta, J

    2015-10-01

    The aim of orthopedic trauma surgery is to restore the anatomy and function of displaced bone fragments to support osteosynthesis. For complex cases, including pelvic bone and multi-fragment femoral neck and distal radius fractures, preoperative planning with a CT scan is indicated. The planning consists of (1) fracture reduction-determining the locations and anatomical sites of origin of the fractured bone fragments and (2) fracture fixation-selecting and placing fixation screws and plates. The current bone fragment manipulation, hardware selection, and positioning processes based on 2D slices and a computer mouse are time-consuming and require a technician. We present a novel 3D haptic-based system for patient-specific preoperative planning of orthopedic fracture surgery based on CT scans. The system provides the surgeon with an interactive, intuitive, and comprehensive, planning tool that supports fracture reduction and fixation. Its unique features include: (1) two-hand haptic manipulation of 3D bone fragments and fixation hardware models; (2) 3D stereoscopic visualization and multiple viewing modes; (3) ligaments and pivot motion constraints to facilitate fracture reduction; (4) semiautomatic and automatic fracture reduction modes; and (5) interactive custom fixation plate creation to fit the bone morphology. We evaluate our system with two experimental studies: (1) accuracy and repeatability of manual fracture reduction and (2) accuracy of our automatic virtual bone fracture reduction method. The surgeons achieved a mean accuracy of less than 1 mm for the manual reduction and 1.8 mm (std [Formula: see text] 1.1 mm) for the automatic reduction. 3D haptic-based patient-specific preoperative planning of orthopedic fracture surgery from CT scans is useful and accurate and may have significant advantages for evaluating and planning complex fractures surgery.

  18. The Effect of Contact Area on the Fluid Flow-Fracture Specific Stiffness Relationship

    NASA Astrophysics Data System (ADS)

    Petrovitch, C.; Pyrak-Nolte, L. J.; Nolte, D. D.

    2009-12-01

    The integrity of subsurface CO2 sequestration sites can be compromised by the presence of mechanical discontinuities such as fractures, joints and faults. The ability to detect, seismically, and determine whether a discontinuity poses a risk, requires an understanding of the interrelationships among the mechanical, hydraulic and seismic properties of fractures rock. We performed a computational study to investigate the effect of fracture geometry on the relationship between fluid flow and fracture specific stiffness. The form of this relationship and the ability to scale it among different sample sizes provides a key link between the hydraulic and seismic response of fractures. In this study, model fracture topologies were simulated using the stratified continuum percolation method. This method constructs a hierarchical aperture distribution with a tunable spatial correlation length. Fractures with correlated and uncorrelated aperture distributions were used. The contact area across the fracture plane ranged from approximately 5% to 40%. The fracture specific stiffness was calculated by deforming each fracture numerically under a normal load and extracting the stiffness from the displacement-stress curves. Single-phase flow was calculated for each increment of stress by modeling the fracture topology as a network of elliptical pipes and solving the corresponding linear system of equations. We analyzed the relationship between fracture displacement and contact area and found that the correlation length associated with the contact area distribution enables a scaling relationship between displacement and contact area. The collapse of the fluid flow - stress relationship required use of standard percolation functional forms that use average aperture (cubic law), the void area fraction, and the correlation length of the contact area clusters. A final scaling relationship between fluid flow and fracture specific was found for the class of correlated fractures while a separate relationship was found for the uncorrelated fractures. By expanding the scaling parameters to include additional length scales, it may be possible to unify all of the flow-stiffness relationships, independent of geometry. Acknowledgments: The authors wish to acknowledge support of this work by the Geosciences Research Program, Office of Basic Energy Sciences US Department of Energy (DEFG02-97ER14785 08), the GeoMathematical Imaging Group at Purdue University and from the Computer Research Institute At Purdue University.

  19. Intramedullary Fixation of Midshaft Clavicle Fractures.

    PubMed

    Fritz, Erik M; van der Meijden, Olivier A; Hussain, Zaamin B; Pogorzelski, Jonas; Millett, Peter J

    2017-08-01

    Clavicle fractures are among the most common fractures occurring in the general population, and the vast majority are localized in the midshaft portion of the bone. Management of midshaft clavicle fractures remains controversial. Although many can be managed nonoperatively, certain patient populations and fracture patterns, such as completely displaced and shortened fractures, are at risk of less optimal outcomes with nonoperative management; surgical intervention should be considered in such cases. The purpose of this article is to demonstrate our technique of midshaft clavicle fixation using minimally invasive intramedullary fixation.

  20. Time dependent fracture and cohesive zones

    NASA Technical Reports Server (NTRS)

    Knauss, W. G.

    1993-01-01

    This presentation is concerned with the fracture response of materials which develop cohesive or bridging zones at crack tips. Of special interest are concerns regarding crack stability as a function of the law which governs the interrelation between the displacement(s) or strain across these zones and the corresponding holding tractions. It is found that for some materials unstable crack growth can occur, even before the crack tip has experienced a critical COD or strain across the crack, while for others a critical COD will guarantee the onset of fracture. Also shown are results for a rate dependent nonlinear material model for the region inside of a craze for exploring time dependent crack propagation of rate sensitive materials.

  1. Permeability - Fluid Pressure - Stress Relationship in Fault Zones in Shales

    NASA Astrophysics Data System (ADS)

    Henry, P.; Guglielmi, Y.; Morereau, A.; Seguy, S.; Castilla, R.; Nussbaum, C.; Dick, P.; Durand, J.; Jaeggi, D.; Donze, F. V.; Tsopela, A.

    2016-12-01

    Fault permeability is known to depend strongly on stress and fluid pressures. Exponential relationships between permeability and effective pressure have been proposed to approximate fault response to fluid pressure variations. However, the applicability of these largely empirical laws remains questionable, as they do not take into account shear stress and shear strain. A series of experiments using mHPP probes have been performed within fault zones in very low permeability (less than 10-19 m2) Lower Jurassic shale formations at Tournemire (France) and Mont Terri (Switzerland) underground laboratories. These probes allow to monitor 3D displacement between two points anchored to the borehole walls at the same time as fluid pressure and flow rate. In addition, in the Mont-Terri experiment, passive pressure sensors were installed in observation boreholes. Fracture transmissivity was estimated from single borehole pulse test, constant pressure injection tests, and cross-hole tests. It is found that the transmissivity-pressure dependency can be approximated with an exponential law, but only above a pressure threshold that we call the Fracture Opening Threshold (F.O.P). The displacement data show a change of the mechanical response across the F.O.P. The displacement below the F.O.P. is dominated by borehole response, which is mostly elastic. Above F.O.P., the poro-elasto-plastic response of the fractures dominates. Stress determinations based on previous work and on the analysis of slip data from mHPPP probe indicate that the F.O.P. is lower than the least principal stress. Below the F.O.P., uncemented fractures retain some permeability, as pulse tests performed at low pressures yield diffusivities in the range 10-2 to 10-5 m2/s. Overall, this dual behavior appears consistent with the results of CORK experiments performed in accretionary wedge decollements. Results suggest (1) that fault zones become highly permeable when approaching the critical Coulomb threshold (2) that fluid pressure diffusion along faults could occur in subcritical conditions and that this may influence their longer-term mechanical stability.

  2. Bilateral femoral neck stress fractures in a fire academy student.

    PubMed

    Wright, Russell C; Salzman, Garrett A; Yacoubian, Stephan V; Yacoubian, Shahan V

    2010-10-11

    Unilateral femoral neck stress fractures are well documented in active patients; however, the risk of a subsequent contralateral stress fracture remains unknown in patients who continue to be active. This article describes a 24-year-old male fire academy student who sustained a left femoral neck stress fracture, followed approximately 11 months later by a right femoral neck stress fracture, both of which went on to completely displace. A review of the index radiographs of each hip from outside institutions revealed femoral neck stress fractures that went undiagnosed until they displaced. The patient was referred to our institution and underwent closed reduction and internal fixation using cannulated screws in both cases. A full endocrine evaluation was performed in the following weeks and proved unremarkable. Although it is difficult to extrapolate the results from 1 patient beyond the case studied, there is cause for concern in patients who remain active following femoral neck stress fractures. Our case highlights the significance of obtaining a complete and thorough medical history on physical examination and appropriately counseling patients regarding activity level. Until further research explores this possible relationship, physicians evaluating patients with a history of a stress fracture are encouraged to be vigilant of subsequent contralateral fractures and educate patients of this potentially avoidable injury. Copyright 2010, SLACK Incorporated.

  3. Recovery of mouth-opening after closed treatment of a fracture of the mandibular condyle: a longitudinal study.

    PubMed

    Niezen, E T; Stuive, I; Post, W J; Bos, R R M; Dijkstra, P U

    2015-02-01

    The aim of this retrospective study was to assess recovery of mouth opening after closed treatment of fractures of the mandibular condyle, and analyse which characteristics might influence recovery. We measured mouth opening in 142 patients (mean (SD) age 30 (14) years, 96 of whom were male) during follow-up at 3, 6, 13, 26, and 52 weeks after the injury. Fractures were assessed on radiographs. Data were analysed using a multilevel analysis. Half the fractures were of the low condylar neck (n=71). Thirty-seven patients had bilateral condylar fractures, 29 had dislocated fractures, and in 80 the fracture was displaced. One or more additional mandibular fractures were present in 68. During follow-up mean (SD) mouth opening increased to: 33.6 (9.6) at 3 weeks, 40.1 (10.0) at 6 weeks, 45.1 (9.6) at 13 weeks, 49.8 (9.5) at 26 weeks, and 52.6 (7.5) at 52 weeks. Older age, female sex, displaced fracture, bilateral fractures, additional mandibular fractures, and the interaction between follow-up time and additional mandibular fractures, were predictors of a less favourable recovery of mouth opening. Clinicians can use the results of this study to predict recovery of mouth opening after closed treatment of fractures of the mandibular condyle at first consultation. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Olecranon stress fracture in a weight lifter: a case report

    PubMed Central

    Rao, P; Rao, S; Navadgi, B

    2001-01-01

    Stress fractures have been reported in the upper limb of sportspeople involved in upper limb dominated events. Olecranon stress fractures have been cited in baseball pitchers, javelin throwers, and gymnasts. The unusual case of a stress fracture of the olecranon in a young weight lifter is reported here. The minimally displaced stress fracture was treated with tension band and two Kirschner wires. The fracture healed in four months and the patient returned to light sports activity after six months. Key Words: weight lifter; olecranon; elbow; stress fracture PMID:11157469

  5. Dynamic finite element analysis and moving particle simulation of human enamel on a microscale.

    PubMed

    Yamaguchi, Satoshi; Coelho, Paulo G; Thompson, Van P; Tovar, Nick; Yamauchi, Junpei; Imazato, Satoshi

    2014-12-01

    The study of biomechanics of deformation and fracture of hard biological tissues involving organic matrix remains a challenge as variations in mechanical properties and fracture mode may have time-dependency. Finite element analysis (FEA) has been widely used but the shortcomings of FEA such as the long computation time owing to re-meshing in simulating fracture mechanics have warranted the development of alternative computational methods with higher throughput. The aim of this study was to compare dynamic two-dimensional FEA and moving particle simulation (MPS) when assuming a plane strain condition in the modeling of human enamel on a reduced scale. Two-dimensional models with the same geometry were developed for MPS and FEA and tested in tension generated with a single step of displacement. The displacement, velocity, pressure, and stress levels were compared and Spearman׳s rank-correlation coefficients R were calculated (p<0.001). The MPS and FEA were significantly correlated for displacement, velocity, pressure, and Y-stress. The MPS may be further developed as an alternative approach without mesh generation to simulate deformation and fracture phenomena of dental and potentially other hard tissues with complex microstructure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Development of a Novel Synthetic Drug for Osteoporosis and Fracture Healing

    DTIC Science & Technology

    2015-11-01

    Four-point bending setup for mechanical testing. (C & D) X-ray images of the fractured tibiae. Of note, a stainless steel rod was inserted in the...respectively. Figure 15. Mechanical strength 4 weeks after fracture induction for experiment 1. (A) Force- displacement relationship for the hydrogel...University Purdue University Indianapolis, Indianapolis, IN 46202, USA Keywords: bone fracture , tibia, salubrinal, hydrogel, mechanical test Running

  7. Selecting boundary conditions in physiological strain analysis of the femur: Balanced loads, inertia relief method and follower load.

    PubMed

    Heyland, Mark; Trepczynski, Adam; Duda, Georg N; Zehn, Manfred; Schaser, Klaus-Dieter; Märdian, Sven

    2015-12-01

    Selection of boundary constraints may influence amount and distribution of loads. The purpose of this study is to analyze the potential of inertia relief and follower load to maintain the effects of musculoskeletal loads even under large deflections in patient specific finite element models of intact or fractured bone compared to empiric boundary constraints which have been shown to lead to physiological displacements and surface strains. The goal is to elucidate the use of boundary conditions in strain analyses of bones. Finite element models of the intact femur and a model of clinically relevant fracture stabilization by locking plate fixation were analyzed with normal walking loading conditions for different boundary conditions, specifically re-balanced loading, inertia relief and follower load. Peak principal cortex surface strains for different boundary conditions are consistent (maximum deviation 13.7%) except for inertia relief without force balancing (maximum deviation 108.4%). Influence of follower load on displacements increases with higher deflection in fracture model (from 3% to 7% for force balanced model). For load balanced models, follower load had only minor influence, though the effect increases strongly with higher deflection. Conventional constraints of fixed nodes in space should be carefully reconsidered because their type and position are challenging to justify and for their potential to introduce relevant non-physiological reaction forces. Inertia relief provides an alternative method which yields physiological strain results. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Natural history of medial clavicle fractures.

    PubMed

    Salipas, Andrew; Kimmel, Lara A; Edwards, Elton R; Rakhra, Sandeep; Moaveni, Afshin Kamali

    2016-10-01

    Fractures of the medial third of the clavicle comprise less than 3% of all clavicle fractures. The natural history and optimal management of these rare injuries are unknown. The aim of our study is to describe the demographics, management and outcomes of patients with medial clavicle fractures treated at a Level 1 Trauma Centre. A retrospective review was conducted of patients presenting to our institution between January 2008 and March 2013 with a medial third clavicle fracture. Clinical and radiographic data were recorded including mechanism of injury, fracture pattern and displacement, associated injuries, management and complications. Functional outcomes were assessed using the Glasgow Outcome Scale Extended (GOS-E) scores from the Victorian Orthopaedic Trauma Outcomes Registry (VOTOR). Shoulder outcomes were assessed using two patient reported outcomes scores, the American Shoulder and Elbow Society Score (ASES) and the Subjective Shoulder Value (SSV). Sixty eight medial clavicle fractures in 68 patients were evaluated. The majority of patients were male (n=53), with a median age of 53.5 years (interquartile range (IQR) 37.5-74.5 years). The most common mechanism of injury was motor vehicle accident (n=28). The in-hospital mortality rate was 4.4%. The fracture pattern was almost equally distributed between extra articular (n=35) and intra-articular (n=33). Fifty-five fractures (80.9%) had minimal or no displacement. Associated injuries were predominantly thoracic (n=31). All fractures were initially managed non-operatively, with a broad arm sling. Delayed operative fixation was performed for painful atrophic delayed union in two patients (2.9%). Both patients were under 65 years of age and had a severely displaced fracture of the medial clavicle. One intra-operative vascular complication was seen, with no adverse long-term outcome. Follow-up was obtained in 85.0% of the surviving cohort at an average of three years post injury (range 1-6 years). The mean ASES score was 80.3 (SD 24.8, range 10-100,), and the mean SSV score was 77.0 (SD 24.6, range 10-100). Sixty eight patients with medial clavicle fractures were identified over a 5year period, with excellent functional results seen following conservative management. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures.

    PubMed

    Gali, Rajasekhar; Devireddy, Sathya Kumar; Venkata, Kishore Kumar Rayadurgam; Kanubaddy, Sridhar Reddy; Nemaly, Chaithanyaa; Dasari, Mallikarjuna

    2016-01-01

    Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP) approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a) the ease of access for retrieval, reimplantation and fixation of the proximal segment; b) the postoperative approach related complications; c) the adequacy of anatomical reduction and stability of fixation; d) the occlusal changes; and the e) TMJ function and radiological changes. Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch) palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby permitting perpendicular placement of screws with minimal risk of damage to the facial nerve.

  10. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures

    PubMed Central

    Gali, Rajasekhar; Devireddy, Sathya Kumar; Venkata, Kishore Kumar Rayadurgam; Kanubaddy, Sridhar Reddy; Nemaly, Chaithanyaa; Dasari, Mallikarjuna

    2016-01-01

    Introduction: Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. Purpose: This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP) approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. Patients and Methods: This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a) the ease of access for retrieval, reimplantation and fixation of the proximal segment; b) the postoperative approach related complications; c) the adequacy of anatomical reduction and stability of fixation; d) the occlusal changes; and the e) TMJ function and radiological changes. Results: Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch) palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. Conclusion: The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby permitting perpendicular placement of screws with minimal risk of damage to the facial nerve. PMID:27274123

  11. Transmasseteric anterior parotid approach for condylar fractures: experience of 129 cases.

    PubMed

    Narayanan, Vinod; Ramadorai, Ashok; Ravi, Poornima; Nirvikalpa, Natarajan

    2012-07-01

    We have evaluated the transmasseteric anterior parotid (TMAP) approach in the treatment of 163 condylar fractures in 129 patients. Ninety-five patients presented with unilateral, and 34 with bilateral, fractures. The inclusion criteria were patient's choice for open reduction and internal fixation, displaced unilateral condylar fractures with occlusal derangement, and displaced bilateral condylar fractures with anterior open bite. Mean (SD) maximum interincisal opening after 3 months was 44(5)mm. There were no differences in lateral movements during the reviews 6 weeks and 3 months postoperatively. Protrusive movement at the end of 3 months was 7(2)mm. All patients achieved functional occlusion identical to the pretraumatic occlusion and good reduction of the condyles. No patient developed temporary or permanent facial palsy, sialocele, salivary fistula, or Frey syndrome. The mean (SD) operating time was 46(11)min. The TMAP approach avoids the complications of incision of the parotid gland, minimises the risk of facial nerve palsy, and offers excellent access to the fractured condyle. Copyright © 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Finite element analysis to determine the stress distribution, displacement and safety factor on a microplate for the fractured jaw case

    NASA Astrophysics Data System (ADS)

    Pratama, Juan; Mahardika, Muslim

    2018-03-01

    Microplate is a connecting plate that can be used for jaw bone fixation. In the last two decades, microplate has been used so many times to help reconstruction of fractured jaw bone which is called mandibular bone or mandible bone. The plate is used to provide stable fixation of the fractured bone tissue during healing and reconstruction process. In this study Finite Element Analysis was used to predict the stress concentration and distribution on a microplate, displacement on the microplate and also to determine the safety factor of the microplate based on maximum allowable stress value, and finally to ascertain whether microplate is safe to use or not. The microplate was produced from punching process using titanium grade 1 (pure titanium) as material with a thickness of 500 µm. The results of the research indicated that the microplate was safe to use according to the maximum stress around the hole, displacement around the hole and also the safety factor of the microplate.

  13. Fracture Patterns within the Shale Hills Critical Zone Observatory

    NASA Astrophysics Data System (ADS)

    Singha, K.; White, T.; Perron, J.; Chattopadhyay, P. B.; Duffy, C.

    2012-12-01

    Rock fractures are known to exist within the deep Critical Zone and are expected to influence groundwater flow, but there are limited data on their orientation and spatial arrangement and no general framework for systematically predicting their effects. Here, we explore fracture patterns within the Susquehanna-Shale Hills Critical Zone Observatory, and consider how they may be influenced by weathering, rock structure, and stress via field observations of variable fracture orientation within the site, with implications for the spatial variability of structural control on hydrologic processes. Based on field observations from 16-m deep boreholes and surface outcrop, we suggest that the appropriate structural model for the watershed is steeply dipping strata with meter- to decimeter-scale folds superimposed, including a superimposed fold at the mouth of the watershed that creates a short fold limb with gently dipping strata. These settings would produce an anisotropy in the hydraulic conductivity and perhaps also flow, especially within the context of the imposed stress field. Recently conducted 2-D numerical stress modeling indicates that the proxy for shear fracture declines more rapidly with depth beneath valleys than beneath ridgelines, which may produce or enhance the spatial variability in permeability. Even if topographic stresses do not cause new fractures, they could activate and cause displacement on old fractures, making the rocks easier to erode and increasing the permeability, and potentially driving a positive feedback that enhances the growth of valley relief. Calculated stress fields are consistent with field observations, which show a rapid decline in fracture abundance with increasing depth below the valley floor, and predict a more gradual trend beneath ridgetops, leading to a more consistent (and lower) hydraulic conductivity with depth on the ridgetops when compared to the valley, where values are higher but more variable with depth. Hydraulic conductivity is a fundamental property controlling the zone of active flow within the watershed.

  14. On the mode I fracture analysis of cracked Brazilian disc using a digital image correlation method

    NASA Astrophysics Data System (ADS)

    Abshirini, Mohammad; Soltani, Nasser; Marashizadeh, Parisa

    2016-03-01

    Mode I of fracture of centrally cracked Brazilian disc was investigated experimentally using a digital image correlation (DIC) method. Experiments were performed on PMMA polymers subjected to diametric-compression load. The displacement fields were determined by a correlation between the reference and the deformed images captured before and during loading. The stress intensity factors were calculated by displacement fields using William's equation and the least square algorithm. The parameters involved in the accuracy of SIF calculation such as number of terms in William's equation and the region of analysis around the crack were discussed. The DIC results were compared with the numerical results available in literature and a very good agreement between them was observed. By extending the tests up to the critical state, mode I fracture toughness was determined by analyzing the image of specimen captured at the moment before fracture. The results showed that the digital image correlation was a reliable technique for the calculation of the fracture toughness of brittle materials.

  15. Arthroscopic Management of Tibial Spine Avulsion Fractures: Principles and Techniques.

    PubMed

    Strauss, Eric J; Kaplan, Daniel James; Weinberg, Maxwell E; Egol, Jonathan; Jazrawi, Laith M

    2018-05-15

    Tibial spine fractures are uncommon injuries affecting the insertion of the anterior cruciate ligament on the tibia. They typically occur in skeletally immature patients aged 8 to 14 years and result from hyperextension of the knee with a valgus or rotational force. Diagnosis is based on history, physical examination, and standard radiographs. The use of MRI can identify entrapped soft tissue that may prevent reduction. Open or arthroscopic repair is indicated in patients with partially displaced fractures (>5 mm) with one third to one half of the avulsed fragment elevated, in patients who have undergone unsuccessful nonsurgical reduction and long leg casting or bracing, and in patients with completely displaced fractures. Arthroscopy offers reduced invasiveness and decreased morbidity. Suture fixation and screw fixation have produced successful results. Suture fixation can eliminate the risk of fracture fragment comminution during screw insertion, the risk of neurovascular injury, and the need for hardware removal. Suture fixation is ideal in cases in which existing comminution prevents screw fixation.

  16. Operative versus non-operative treatment for closed, displaced, intra-articular fractures of the calcaneus: randomised controlled trial.

    PubMed

    Griffin, Damian; Parsons, Nick; Shaw, Ewart; Kulikov, Yuri; Hutchinson, Charles; Thorogood, Margaret; Lamb, Sarah E

    2014-07-24

    To investigate whether surgery by open reduction and internal fixation provides benefit compared with non-operative treatment for displaced, intra-articular calcaneal fractures. Pragmatic, multicentre, two arm, parallel group, assessor blinded randomised controlled trial (UK Heel Fracture Trial). 22 tertiary referral hospitals, United Kingdom. 151 patients with acute displaced intra-articular calcaneal fractures randomly allocated to operative (n=73) or non-operative (n=78) treatment. The primary outcome measure was patient reported Kerr-Atkins score for pain and function (scale 0-100, 100 being the best possible score) at two years after injury. Secondary outcomes were complications; hindfoot pain and function (American Orthopaedic Foot and Ankle Society score); general health (SF-36); quality of life (EQ-5D); clinical examination; walking speed; and gait symmetry. Analysis was by intention to treat. 95% follow-up was achieved for the primary outcome (69 in operative group and 74 in non-operative group), and a complete set of secondary outcomes were available for 75% of participants. There was no significant difference in the primary outcome (mean Kerr-Atkins score 69.8 in operative group v 65.7 in non-operative group; adjusted 95% confidence interval of difference -7.1 to 7.0) or in any of the secondary outcomes between treatment groups. Complications and reoperations were more common in those who received operative care (estimated odds ratio 7.5, 95% confidence interval 2.0 to 41.8). Operative treatment compared with non-operative care showed no symptomatic or functional advantage after two years in patients with typical displaced intra-articular fractures of the calcaneus, and the risk of complications was higher after surgery. Based on these findings, operative treatment by open reduction and internal fixation is not recommended for these fractures.Trial registration Current Controlled Trials ISRCTN37188541. © Griffin et al 2014.

  17. Fault and fracture patterns in low porosity chalk and their potential influence on sub-surface fluid flow-A case study from Flamborough Head, UK

    NASA Astrophysics Data System (ADS)

    Sagi, D. A.; De Paola, N.; McCaffrey, K. J. W.; Holdsworth, R. E.

    2016-10-01

    To better understand fault zone architecture and fluid flow in mesoscale fault zones, we studied normal faults in chalks with displacements up to 20 m, at two representative localities in Flamborough Head (UK). At the first locality, chalk contains cm-thick, interlayered marl horizons, whereas at the second locality marl horizons were largely absent. Cm-scale displacement faults at both localities display ramp-flat geometries. Mesoscale fault patterns in the marl-free chalk, including a larger displacement fault (20 m) containing multiple fault strands, show widespread evidence of hydraulically-brecciated rocks, whereas clays smears along fault planes, and injected into open fractures, and a simpler fault zone architecture is observed where marl horizons are present. Hydraulic brecciation and veins observed in the marl-free chalk units suggest that mesoscale fault patterns acted as localized fault conduit allowing for widespread fluid flow. On the other hand, mesoscale fault patterns developed in highly fractured chalk, which contains interlayered marl horizons can act as localized barriers to fluid flow, due to the sealing effect of clays smears along fault planes and introduced into open fractures in the damage zone. To support our field observations, quantitative analyses carried out on the large faults suggest a simple fault zone in the chalk with marl units with fracture density/connectivity decreasing towards the protolith. Where marls are absent, density is high throughout the fault zone, while connectivity is high only in domains nearest the fault core. We suggest that fluid flow in fractured chalk is especially influenced by the presence of marls. When present, it can smear onto fault planes, forming localised barriers. Fluid flow along relatively large displacement faults is additionally controlled by the complexity of the fault zone, especially the size/geometry of weakly and intensely connected damage zone domains.

  18. a Predictive Model of Permeability for Fractal-Based Rough Rock Fractures during Shear

    NASA Astrophysics Data System (ADS)

    Huang, Na; Jiang, Yujing; Liu, Richeng; Li, Bo; Zhang, Zhenyu

    This study investigates the roles of fracture roughness, normal stress and shear displacement on the fluid flow characteristics through three-dimensional (3D) self-affine fractal rock fractures, whose surfaces are generated using the modified successive random additions (SRA) algorithm. A series of numerical shear-flow tests under different normal stresses were conducted on rough rock fractures to calculate the evolutions of fracture aperture and permeability. The results show that the rough surfaces of fractal-based fractures can be described using the scaling parameter Hurst exponent (H), in which H = 3 - Df, where Df is the fractal dimension of 3D single fractures. The joint roughness coefficient (JRC) distribution of fracture profiles follows a Gauss function with a negative linear relationship between H and average JRC. The frequency curves of aperture distributions change from sharp to flat with increasing shear displacement, indicating a more anisotropic and heterogeneous flow pattern. Both the mean aperture and permeability of fracture increase with the increment of surface roughness and decrement of normal stress. At the beginning of shear, the permeability increases remarkably and then gradually becomes steady. A predictive model of permeability using the mean mechanical aperture is proposed and the validity is verified by comparisons with the experimental results reported in literature. The proposed model provides a simple method to approximate permeability of fractal-based rough rock fractures during shear using fracture aperture distribution that can be easily obtained from digitized fracture surface information.

  19. In-Situ X-ray Tomography Observation of Structure Evolution in 1,3,5-Triamino-2,4,6-Trinitrobenzene Based Polymer Bonded Explosive (TATB-PBX) under Thermo-Mechanical Loading.

    PubMed

    Yuan, Zeng-Nian; Chen, Hua; Li, Jing-Ming; Dai, Bin; Zhang, Wei-Bin

    2018-05-04

    In order to study the fracture behavior and structure evolution of 1,3,5-Triamino-2,4,6-Trinitrobenzene (TATB)-based polymer bonded explosive in thermal-mechanical loading, in-situ studies were performed on X-ray computed tomography system using quasi-static Brazilian test. The experiment temperature was set from −20 °C to 70 °C. Three-dimensional morphology of cracks at different temperatures was obtained through digital image process. The various fracture modes were compared by scanning electron microscopy. Fracture degree and complexity were defined to quantitatively characterize the different types of fractures. Fractal dimension was used to characterize the roughness of the crack surface. The displacement field of particles in polymer bonded explosive (PBX) was used to analyze the interior structure evolution during the process of thermal-mechanical loading. It was found that the brittleness of PBX reduced, the fracture got more tortuous, and the crack surface got smoother as the temperature rose. At lower temperatures, especially lower than glass transition temperature of binders, there were slipping and shear among particles, and particles tended to displace and disperse; while at higher temperatures, especially above the glass transition temperature of binders, there was reorganization of particles and particles tended to merge, disperse, and reduce sizes, rather than displacing.

  20. Development of a Titanium Plate for Mandibular Angle Fractures with a Bone Defect in the Lower Border: Finite Element Analysis and Mechanical Test

    PubMed Central

    Goulart, Douglas Rangel; Kemmoku, Daniel Takanori; Noritomi, Pedro Yoshito

    2015-01-01

    ABSTRACT Objectives The aim of the present study was to develop a plate to treat mandibular angle fractures using the finite element method and mechanical testing. Material and Methods A three-dimensional model of a fractured mandible was generated using Rhinoceros 4.0 software. The models were exported to ANSYS®, in which a static application of displacement (3 mm) was performed in the first molar region. Three groups were assessed according to the method of internal fixation (2 mm system): two non-locking plates; two locking plates and a new design locking plate. The computational model was transferred to an in vitro experiment with polyurethane mandibles. Each group contained five samples and was subjected to a linear loading test in a universal testing machine. Results A balanced distribution of stress was associated with the new plate design. This plate modified the mechanical behavior of the fractured region, with less displacement between the fractured segments. In the mechanical test, the group with two locking plates exhibited greater resistance to the 3 mm displacement, with a statistically significant difference when compared with the new plate group (ANOVA, P = 0.016). Conclusions The new plate exhibited a more balanced distribution of stress. However, the group with two locking plates exhibited greater mechanical resistance. PMID:26539287

  1. [Comparing different treatments for femoral neck fracture of displacement type in the elderly:a meta analysis].

    PubMed

    Zhao, Wenbo; Tu, Chongqi; Zhang, Hui; Fang, Yue; Wang, Guanglin; Liu, Lei

    2014-04-01

    To compare the effects and security between internal fixation and total hip arthroplasty for the patients in elderly with femoral neck fracture of displacement type through a meta analysis. Studies on comparison between internal fixation and total hip arthroplasty for the patients in the elderly with femoral neck fracture of displacement type were identified from PubMed database,EMBase database, COCHRANE library, CMB database, CNKI database and MEDLINE database. Data analysis were performed using Revman 5.2.6(the Cochrane Collaboration). Six published randomized controlled trials including 627 patients were suitable for the review, 286 cases in internal fixation group and 341 cases in total hip arthroplasty group. The results of meta analysis indicated that statistically significant difference were observed between the two groups in the quality of life which was reflected by the Harris scale (RR = 0.82, 95%CI:0.72-0.93, P < 0.05) , the reoperation rate (RR = 5.81, 95%CI:3.09-10.95, P < 0.05) and the major complications rate (RR = 3.60, 95%CI:2.29-5.67, P < 0.05) postoperatively. There were no difference in the mortality at 1 year and 5 years postoperatively(P > 0.05). For the patients with femoral neck fracture of displacement type in the elderly, there is no statistical difference between two groups in the mortality postoperatively. The quality of life and the security of operation in internal fixation group is worse than the total hip arthroplasty group.

  2. Open versus closed reduction: diacapitular fractures of the mandibular condyle.

    PubMed

    Chrcanovic, Bruno Ramos

    2012-09-01

    The purpose of the study was to review the literature regarding the evolution of current thoughts on management of diacapitular fractures (DFs) of the mandibular condyle. An electronic search in PubMed was undertaken in March 2012. The titles and abstracts from these results were read to identify studies within the selection criteria. Eligibility criteria included studies reporting clinical series of DFs, including both animal and human studies, without date or language restrictions. The search strategy initially yielded 108 references. Twenty-eight studies were identified without repetition within the selection criteria. Additional hand-searching of the reference lists of selected studies yielded three additional papers. The current indications for open reduction and internal fixation (ORIF) of DFs described in the literature are: (a) fractures affecting the lateral condyle with reduction of mandibular height; (b) fractures in which the proximal fragment dislocates laterally out of the glenoid fossa, which cannot be reduced by closed or open treatment of another part of the mandibular fracture. The indications for conservative treatment are: (a) fractures that do not shorten the condylar height (a fracture with displacement of the medial parts of the condyle); (b) undisplaced fractures; (c) comminution of the condylar head, when the bony fragments are too small for stable fixation; and (d) fractures in children. As the temporomandibular joint disk plays an important role as a barrier preventing ankylosis, it is important to reposition the disk (if displaced/dislocated) during the surgical treatment of DFs. The lateral pterygoid muscle should never be stripped from the medially displaced fragment because its desinsertion disrupts circulation to the medial bony fragment, and also because this muscle helps to restore the muscle function after surgery. ORIF of selected DFs improves prognosis by anatomical bone and soft tissue recovery when combined with physical therapy. If conducted properly, surgical treatment of DFs is a safe and predictable procedure and yields good results.

  3. Lateral Radiograph of the Hip in Fracture Neck of Femur: Is it a Ritual?

    PubMed

    Kumar, Dheerendra S; Gubbi, Shivarathre D; Abdul, Bari; Bisalahalli, Muddu

    2008-10-01

    Historically routine work up of a patient with a fracture neck of femur has always included an antero-posterior (AP) and a lateral view of the hip. The aim of the study was to know whether a lateral view of hip influenced the decision of an Orthopedic Surgeon regarding management at a District General Hospital. A prospective study was conducted from February 2005 to September 2005 at Tameside General Hospital. X-rays of patients admitted with fracture neck of femur were shown to two independent observers in the daily trauma meeting. AP view of the hip was shown initially to observers and their classification and intended treatment was recorded. They were asked if they needed a lateral view to decide on management option and answers were recorded. The observers were then showed a lateral view of same hip and asked to comment on quality of film and also whether it would change their classification or intended management. There were 100 patients over six months. On AP view 56 were classified to have extra-capsular fracture, 37 were classified as displaced subcapital fracture and seven were classified undisplaced subcapital fracture. There was an interobserver variation in one patient between undisplaced or displaced subcapital fracture. The observers felt they would need a lateral X-ray on three occasions and there was a change in classification from undisplaced subcapital to displaced subcapital fracture on first occasion. There was no change in management plan in all the 100 patients after looking at a lateral X-ray. We can conclude that unless required for management a lateral X-ray of hip should be avoided routinely in all patients with fracture neck of femur as it would not only be cost effective but will also reduce radiation exposure to patient and relieve work pressure on radiographers, nursing and portering staff.

  4. Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes.

    PubMed

    Anwar, Adeel; Lv, Decheng; Zhao, Zhi; Zhang, Zhen; Lu, Ming; Nazir, Muhammad Umar; Qasim, Wasim

    2017-04-01

    Appropriate fixation method for the posterior malleolar fractures (PMF) according to the fracture size is still not clear. Aim of this study was to evaluate the outcomes of the different fixation methods used for fixation of PMF by finite element analysis (FEA) and to compare the effect of fixation constructs on the size of the fracture computationally. Three dimensional model of the tibia was reconstructed from computed tomography (CT) images. PMF of 30%, 40% and 50% fragment sizes were simulated through computational processing. Two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior buttress plate were analysed for three different fracture volumes. The simulated loads of 350N and 700N were applied to the proximal tibial end. Models were fixed distally in all degrees of freedom. In single limb standing condition, the posterior plate group produced the lowest relative displacement (RD) among all the groups (0.01, 0.03 and 0.06mm). Further nodal analysis of the highest RD fracture group showed a higher mean displacement of 4.77mm and 4.23mm in AP and PA lag screws model (p=0.000). The amounts of stress subjected to these implants, 134.36MPa and 140.75MPa were also significantly lower (p=0.000). There was a negative correlation (p=0.021) between implant stress and the displacement which signifies a less stable fixation using AP and PA lag screws. Progressively increasing fracture size demands more stable fixation construct because RD increases significantly. Posterior buttress plate produces superior stability and lowest RD in PMF models irrespective of the fragment size. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Hip fracture evaluation with alternatives of total hip arthroplasty versus hemiarthroplasty (HEALTH): protocol for a multicentre randomised trial.

    PubMed

    Bhandari, Mohit; Devereaux, P J; Einhorn, Thomas A; Thabane, Lehana; Schemitsch, Emil H; Koval, Kenneth J; Frihagen, Frede; Poolman, Rudolf W; Tetsworth, Kevin; Guerra-Farfán, Ernesto; Madden, Kim; Sprague, Sheila; Guyatt, Gordon

    2015-02-13

    Hip fractures are a leading cause of mortality and disability worldwide, and the number of hip fractures is expected to rise to over 6 million per year by 2050. The optimal approach for the surgical management of displaced femoral neck fractures remains unknown. Current evidence suggests the use of arthroplasty; however, there is lack of evidence regarding whether patients with displaced femoral neck fractures experience better outcomes with total hip arthroplasty (THA) or hemiarthroplasty (HA). The HEALTH trial compares outcomes following THA versus HA in patients 50 years of age or older with displaced femoral neck fractures. HEALTH is a multicentre, randomised controlled trial where 1434 patients, 50 years of age or older, with displaced femoral neck fractures from international sites are randomised to receive either THA or HA. Exclusion criteria include associated major injuries of the lower extremity, hip infection(s) and a history of frank dementia. The primary outcome is unplanned secondary procedures and the secondary outcomes include functional outcomes, patient quality of life, mortality and hip-related complications-both within 2 years of the initial surgery. We are using minimisation to ensure balance between intervention groups for the following factors: age, prefracture living, prefracture functional status, American Society for Anesthesiologists (ASA) Class and centre number. Data analysts and the HEALTH Steering Committee are blinded to the surgical allocation throughout the trial. Outcome analysis will be performed using a χ(2) test (or Fisher's exact test) and Cox proportional hazards modelling estimate. All results will be presented with 95% CIs. The HEALTH trial has received local and McMaster University Research Ethics Board (REB) approval (REB#: 06-151). Outcomes from the primary manuscript will be disseminated through publications in academic journals and presentations at relevant orthopaedic conferences. We will communicate trial results to all participating sites. Participating sites will communicate results with patients who have indicated an interest in knowing the results. The HEALTH trial is registered with clinicaltrials.gov (NCT00556842). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures

    PubMed Central

    Meffert, Rainer H.; Raschke, Michael J.; Blunk, Torsten; Ochman, Sabine

    2014-01-01

    Purpose. To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. Methods. Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical screw fixation followed. Under cyclic loading, the displacement, and in subsequent load-to-failure tests, the maximum load and stiffness were measured. Results. For the monocortical screw fixation of the locking plate, a similar displacement, maximum load, and stiffness could be demonstrated compared to the bicortical screw fixation of the nonlocking plate. Conclusions. Locking plates in monocortical configuration may function as a useful alternative to the currently common treatment with bicortical fixations. Thereby, irritation of the flexor tendons would be avoided without compromising the stability, thus enabling the necessary early functional rehabilitation. PMID:24757429

  7. Anterior-Inferior Plating Results in Fewer Secondary Interventions Compared to Superior Plating for Acute Displaced Midshaft Clavicle Fractures.

    PubMed

    Serrano, Rafael; Borade, Amrut; Mir, Hassan; Shah, Anjan; Watson, David; Infante, Anthony; Frankle, Mark A; Mighell, Mark A; Sagi, H Claude; Horwitz, Daniel S; Sanders, Roy W

    2017-09-01

    To determine whether a difference in plate position for fixation of acute, displaced, midshaft clavicle fractures would affect the rate of secondary intervention. Retrospective Comparative Study. Two academic Level 1 Regional Trauma Centers. Five hundred ten patients treated surgically for an acutely displaced midshaft clavicle fracture between 2000 and 2013 were identified and reviewed retrospectively at a minimum of 24 months follow-up (F/U). Fractures were divided into 2 cohorts, according to plate position: Anterior-Inferior (AI) or Superior (S). Exclusion criteria included age <16 years, incomplete data records, and loss to F/U. Group analysis included demographics (age, sex, body mass index), fracture characteristics (mechanism of injury, open or closed), hand dominance, ipsilateral injuries, time between injury to surgery, time to radiographic union, length of F/U, and frequency of secondary procedures. Patients were treated either with AI or S clavicle plating at the treating surgeon's discretion. Rate and reason for secondary intervention. Fisher exact test, t test. and odds ratio were used for statistical analysis. Final analysis included 252 fractures/251 patients. One hundred eighteen (47%) were in group AI; 134 (53%) were in group S. No differences in demographics, fracture characteristics, time to surgery, time to union, or length of F/U existed between groups. Seven patients/7 fractures (5.9%) in Group AI underwent a secondary surgery whereas 30 patients/30 fractures (22.3%) in group S required a secondary surgery. An additional intervention secondary to superior plate placement was highly statistically significant (P < 0.001). Furthermore, because 80% of these subsequent interventions were a result of plate irritation with patient discomfort, the odds ratio for a second procedure was 5 times greater in those fractures treated with a superior plate. This comparative analysis indicates that AI plating of midshaft clavicle fractures seems to lessen clinical irritation and results in significantly fewer secondary interventions. Considering patient satisfaction and a reduced financial burden to the health care system, we recommend routine AI plate application when open reduction internal fixation of the clavicle is indicated. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Fundamental aspects in the quantitative ultrasonic determination of fracture toughness: General equations

    NASA Technical Reports Server (NTRS)

    Fu, L. S.

    1981-01-01

    The problem of establishing a theoretical groundwork for experimentally-found correlations between ultrasonic and fracture toughness factors in polycrystalline metals is discussed. It is noted that the link between these material properties and ultrasonic factors are the microstructural parameters that interact with stress wave propagation during deformation and fracture. The dynamic response of material inhomogeneities and the strains and displacements they undergo under incident stress waves are considered. Dynamic strains and displacements inside and outside scatterers are treated. The underlying approach, the formulation and governing equations for the eigenstrains, and the determination of the energy due to the presence of inhomogeneities are presented. The stress wave interaction problem is presented in terms of the dynamic eigenstrain concept.

  9. Absorbable scaphoid screw development: a comparative study on biomechanics

    PubMed Central

    Wang, Yi; Song, Muguo; Xu, Yongqing; He, Xiaoqing; Zhu, YueLiang

    2016-01-01

    Background The scaphoid is critical for maintaining the stability and movement of the wrist joints. This study aimed to develop a new internal fixator absorbable scaphoid screw (ASS) for fixation of the scaphoid waist after fracture and to test the biomechanical characteristics of ASS. Materials and methods An ASS was prepared using polylactic acids and designed based on scaphoid measurements and anatomic features. Twenty fractured scaphoid waist specimens were randomly divided into experimental and control groups (n=10/group). Reduction and internal fixation of the scaphoid were achieved with either Kirschner wires (K-wires) or ASS. A moving target simulator was used to test palmar flexion and dorsal extension, with the range of testing (waist movement) set from 5° of palmar flexion to 25° of dorsal extension. Flexion and extension were repeated 2,000 times for each specimen. Fracture gap displacements were measured with a computerized tomography scanning. Scaphoid tensile and bending strengths were measured by using a hydraulic pressure biomechanical system. Results Prior to biomechanical fatigue testing, fracture gap displacements were 0.16±0.02 mm and 0.22±0.02 mm in the ASS and K-wire groups, respectively. After fatigue testing, fracture gap displacements in the ASS and the K-wire groups were 0.21±0.03 mm and 1.52±0.07 mm, respectively. The tensile strengths for the ASS and K-wire groups were 0.95±0.02 MPa and 0.63±0.02 MPa, respectively. Conclusion Fixation using an ASS provided sufficient mechanical support for the scaphoid after fracture. PMID:27217756

  10. [LiLa classification for paediatric long bone fractures. Intraobserver and interobserver reliability].

    PubMed

    Kamphaus, A; Rapp, M; Wessel, L M; Buchholz, M; Massalme, E; Schneidmüller, D; Roeder, C; Kaiser, M M

    2015-04-01

    There are two child-specific fracture classification systems for long bone fractures: the AO classification of pediatric long-bone fractures (PCCF) and the LiLa classification of pediatric fractures of long bones (LiLa classification). Both are still not widely established in comparison to the adult AO classification for long bone fractures. During a period of 12 months all long bone fractures in children were documented and classified according to the LiLa classification by experts and non-experts. Intraobserver and interobserver reliability were calculated according to Cohen (kappa). A total of 408 fractures were classified. The intraobserver reliability for location in the skeletal and bone segment showed an almost perfect agreement (K = 0.91-0.95) and also the morphology (joint/shaft fracture) (K = 0.87-0.93). Due to different judgment of the fracture displacement in the second classification round, the intraobserver reliability of the whole classification revealed moderate agreement (K = 0.53-0.58). Interobserver reliability showed moderate agreement (K = 0.55) often due to the low quality of the X-rays. Further differences occurred due to difficulties in assigning the precise transition from metaphysis to diaphysis. The LiLa classification is suitable and in most cases user-friendly for classifying long bone fractures in children. Reliability is higher than in established fracture specific classifications and comparable to the AO classification of pediatric long bone fractures. Some mistakes were due to a low quality of the X-rays and some due to difficulties to classify the fractures themselves. Improvements include a more precise definition of the metaphysis and the kind of displacement. Overall the LiLa classification should still be considered as an alternative for classifying pediatric long bone fractures.

  11. A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis.

    PubMed

    Liu, Yun-Feng; Fan, Ying-Ying; Jiang, Xian-Feng; Baur, Dale A

    2017-11-15

    The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. The customized fixation system with topological optimized structure has good biomechanical behavior for mandibular angle fracture because the stress, strain and displacement within the plate could be reduced significantly comparing to conventional "one mini-plate" or "two mini-plates" systems. The design methodology for customized fixation system could be used for other fractures in mandible or other bones to acquire better mechanical behavior of the system and improve stable environment for bone healing. And together with SLM, the customized plate with optimal structure could be designed and fabricated rapidly to satisfy the urgent time requirements for treatment.

  12. Dependence of displacement-length scaling relations for fractures and deformation bands on the volumetric changes across them

    USGS Publications Warehouse

    Schultz, R.A.; Soliva, R.; Fossen, H.; Okubo, C.H.; Reeves, D.M.

    2008-01-01

    Displacement-length data from faults, joints, veins, igneous dikes, shear deformation bands, and compaction bands define two groups. The first group, having a power-law scaling relation with a slope of n = 1 and therefore a linear dependence of maximum displacement and discontinuity length (Dmax = ??L), comprises faults and shear (non-compactional or non-dilational) deformation bands. These shearing-mode structures, having shearing strains that predominate over volumetric strains across them, grow under conditions of constant driving stress, with the magnitude of near-tip stress on the same order as the rock's yield strength in shear. The second group, having a power-law scaling relation with a slope of n = 0.5 and therefore a dependence of maximum displacement on the square root of discontinuity length (Dmax = ??L0.5), comprises joints, veins, igneous dikes, cataclastic deformation bands, and compaction bands. These opening- and closing-mode structures grow under conditions of constant fracture toughness, implying significant amplification of near-tip stress within a zone of small-scale yielding at the discontinuity tip. Volumetric changes accommodated by grain fragmentation, and thus control of propagation by the rock's fracture toughness, are associated with scaling of predominantly dilational and compactional structures with an exponent of n = 0.5. ?? 2008 Elsevier Ltd.

  13. In Situ Observation of Hard Surrounding Rock Displacement at 2400-m-Deep Tunnels

    NASA Astrophysics Data System (ADS)

    Feng, Xia-Ting; Yao, Zhi-Bin; Li, Shao-Jun; Wu, Shi-Yong; Yang, Cheng-Xiang; Guo, Hao-Sen; Zhong, Shan

    2018-03-01

    This paper presents the results of in situ investigation of the internal displacement of hard surrounding rock masses within deep tunnels at China's Jinping Underground Laboratory Phase II. The displacement evolution of the surrounding rock during the entire excavation processes was monitored continuously using pre-installed continuous-recording multi-point extensometers. The evolution of excavation-damaged zones and fractures in rock masses were also observed using acoustic velocity testing and digital borehole cameras, respectively. The results show four kinds of displacement behaviours of the hard surrounding rock masses during the excavation process. The displacement in the inner region of the surrounding rock was found to be greater than that of the rock masses near the tunnel's side walls in some excavation stages. This leads to a multi-modal distribution characteristic of internal displacement for hard surrounding rock masses within deep tunnels. A further analysis of the evolution information on the damages and fractures inside the surrounding rock masses reveals the effects of excavation disturbances and local geological conditions. This recognition can be used as the reference for excavation and supporting design and stability evaluations of hard-rock tunnels under high-stress conditions.

  14. Electrical and Magnetic Imaging of Proppants in Shallow Hydraulic Fractures

    NASA Astrophysics Data System (ADS)

    Denison, J. L. S.; Murdoch, L. C.; LaBrecque, D. J.; Slack, W. W.

    2015-12-01

    Hydraulic fracturing is an important tool to increase the productivity of wells used for oil and gas production, water resources, and environmental remediation. Currently there are relatively few tools available to monitor the distribution of proppants within a hydraulic fracture, or the propagation of the fracture itself. We have been developing techniques for monitoring hydraulic fractures by injecting electrically conductive, dielectric, or magnetically permeable proppants. We then use the resulting contrast with the enveloping rock to image the proppants using geophysical methods. Based on coupled laboratory and numerical modeling studies, three types of proppants were selected for field evaluation. Eight hydraulic fractures were created near Clemson, SC in May of 2015 by injecting specialized proppants at a depth of 1.5 m. The injections created shallow sub-horizontal fractures extending several meters from the injection point.Each cell had a dense array of electrodes and magnetic sensors on the surface and four shallow vertical electrode arrays that were used to obtain data before and after hydraulic fracturing. Net vertical displacement and transient tilts were also measured. Cores from 130 boreholes were used to characterize the general geometries, and trenching was used to characterize the forms of two of the fractures in detail. Hydraulic fracture geometries were estimated by inverting pre- and post-injection geophysical data. Data from cores and trenching show that the hydraulic fractures were saucer-shaped with a preferred propagation direction. The geophysical inversions generated images that were remarkably similar in form, size, and location to the ground truth from direct observation. Displacement and tilt data appear promising as a constraint on fracture geometry.

  15. Classifications of Acute Scaphoid Fractures: A Systematic Literature Review.

    PubMed

    Ten Berg, Paul W; Drijkoningen, Tessa; Strackee, Simon D; Buijze, Geert A

    2016-05-01

    Background In the lack of consensus, surgeon-based preference determines how acute scaphoid fractures are classified. There is a great variety of classification systems with considerable controversies. Purposes The purpose of this study was to provide an overview of the different classification systems, clarifying their subgroups and analyzing their popularity by comparing citation indexes. The intention was to improve data comparison between studies using heterogeneous fracture descriptions. Methods We performed a systematic review of the literature based on a search of medical literature from 1950 to 2015, and a manual search using the reference lists in relevant book chapters. Only original descriptions of classifications of acute scaphoid fractures in adults were included. Popularity was based on citation index as reported in the databases of Web of Science (WoS) and Google Scholar. Articles that were cited <10 times in WoS were excluded. Results Our literature search resulted in 308 potentially eligible descriptive reports of which 12 reports met the inclusion criteria. We distinguished 13 different (sub) classification systems based on (1) fracture location, (2) fracture plane orientation, and (3) fracture stability/displacement. Based on citations numbers, the Herbert classification was most popular, followed by the Russe and Mayo classifications. All classification systems were based on plain radiography. Conclusions Most classification systems were based on fracture location, displacement, or stability. Based on the controversy and limited reliability of current classification systems, suggested research areas for an updated classification include three-dimensional fracture pattern etiology and fracture fragment mobility assessed by dynamic imaging.

  16. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.

    PubMed

    Costa, Matthew L; Achten, Juul; Parsons, Nick R; Rangan, Amar; Griffin, Damian; Tubeuf, Sandy; Lamb, Sarah E

    2014-08-05

    To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. 18 trauma centres in the United Kingdom. 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient's experience of pain and disability to give a score out of 100. disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was -1.3, 95% confidence interval -4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. Current Controlled Trials ISCRTN 31379280. UKCRN 8956. © Costa et al 2014.

  17. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    PubMed

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve injury. Four patients had a longer recovery period due to stiffness, associated wrist fracture and elbow dislocation. The CaSO4 bone substitute was replaced by normal appearing trabecular bone texture at an average of 6 months in all patients. In our experience, we have found the use of locking plates, calcium sulphate bone substitute and tuberosity repair with high-strength sutures to be a safe and reliable method of internal fixation for complex proximal humeral fractures and fracture-dislocations. Furthermore, we have also found the use of the extended deltoid-splitting approach to be safe and to provide excellent exposure facilitating accurate reduction for fixation of the fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Radial nerve palsy in mid/distal humeral fractures: is early exploration effective?

    PubMed

    Keighley, Geffrey; Hermans, Deborah; Lawton, Vidya; Duckworth, David

    2018-03-01

    Radial nerve palsies are a common complication with displaced distal humeral fractures. This case series examines the outcomes of early operative exploration and decompression of the nerve with fracture fixation with the view that this provides a solid construct for optimisation of nerve recovery. A total of 10 consecutive patients with a displaced distal humeral fracture and an acute radial nerve palsy were treated by the senior author by open reduction and internal fixation of the distal humerus and exploration and decompression of the radial nerve. Motor function and sensation of the radial nerve was assessed in the post-operative period every 2 months or until full recovery of the radial nerve function had occurred. All patients (100%) had recovery of motor and sensation function of their upper limb in the radial nerve distribution over a 12-month period. Recovery times ranged between 4 and 32 weeks, with the median time to recovery occurring at 26 weeks and the average time to full recovery being 22.9 weeks. Wrist extension recovered by an average of 3 months (range 2-26 weeks) and then finger extension started to recover 2-6 weeks after this. Disability of the arm, shoulder and hand scores ranged from 0 to 11.8 at greater than 1 year post-operatively. Our study demonstrated that early operative exploration of the radial nerve when performing an open stabilization of displaced distal humeral fractures resulted in a 100% recovery of the radial nerve. © 2017 Royal Australasian College of Surgeons.

  19. Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study

    PubMed Central

    Liu, Yanjie; Zhang, Wen; Pan, Yao; Zhang, Wei; Zhang, Changqing; Zeng, Bingfang; Chen, Yunfeng

    2015-01-01

    Background The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. Methods Finite element models of the intact clavicle and of midshaft clavicular fractures fixed with TEN and with a reconstruction plate were built. The distal clavicle displacement, peak stress, and stress distribution on the 3 finite element models were calculated under the axial compression and cantilever bending. Results In both loading configurations, TEN generated the highest displacement of the distal clavicle, followed by the intact clavicle and the reconstruction plate. TEN showed higher peak bone and implant stresses, and is more likely to fail in both loading configurations compared with the reconstruction plate. TEN led to a stress distribution similar to that of the intact clavicle in both loading configurations, whereas the stress distribution with the reconstruction plate was nonphysiological in cantilever bending. Conclusions TEN is generally preferable for treating simple displaced fractures of the midshaft clavicle, because it showed a stress distribution similar to the intact clavicle. However, TEN provides less stability, and excessive exercise of and weight bearing on the ipsilateral shoulder should be avoided in the early postoperative period. Fixation with a reconstruction plate was more stable but showed obvious stress shielding. Therefore, for patients with a demand for early return to activity, reconstruction plate fixation may be preferred. PMID:25965409

  20. A Guide for Selecting Remedies for Subsurface Releases of Chlorinated Solvents

    DTIC Science & Technology

    2011-03-01

    exception of secondary permeability features (e.g., fractures , root holes, animal burrows), high displacement pressures typically preclude DNAPL from...1 to 40 percent. Fractured media with high matrix porosity are commonly encountered in sedimentary rock (e.g., limestone, dolomite , shale, and...Low Permeability .......... 21 Type III – Granular Media with Moderate to High Heterogeneity ........................ 21 Type IV - Fractured Media

  1. The anterolateral acromial approach for fractures of the proximal humerus.

    PubMed

    Gardner, Michael J; Boraiah, Sreevathsa; Helfet, David L; Lorich, Dean G

    2008-02-01

    Displaced and unstable fractures of the proximal humerus are notoriously difficult to manage. Successful surgical treatment requires finding the appropriate balance between adequate exposure for reduction and rigid fixation and minimizing soft tissue dissection. The anterolateral acromial approach was developed to allow less invasive treatment of proximal humerus fractures. The plane of the avascular anterior deltoid raphe is utilized, and the axillary nerve is identified and protected. Anterior dissection near the critical blood supply is avoided, substantial muscle retraction is minimized, and the lateral plating zone is directly accessed. Over a 4-year period, 52 patients with acute displaced fractures of the proximal humerus were treated with the anterolateral acromial approach and either a locking plate or an intramedullary nail. Twenty-three patients were evaluated clinically at a minimum follow-up of 1 year (average, 28 months) by clinical examination for range of motion and nerve function and a QuickDASH score. There were no axillary nerve deficits postoperatively related to the approach, and the average QuickDASH score was 25.2 (0, best; 100, worst). This approach allowed direct access to the lateral fracture planes for fracture reduction and plate placement or safe nail and interlocking screw placement.

  2. Chest wall stabilization in trauma patients: why, when, and how?

    PubMed Central

    White, Thomas W.

    2018-01-01

    Blunt trauma to the chest wall and rib fractures are remarkably frequent and are the basis of considerable morbidity and possible mortality. Surgical remedies for highly displaced rib fractures, especially in cases of flail chest, have been undertaken intermittently for more than 50 years. Rib-specific plating systems have started to be used in the last 10 years. These have ushered in the modern era of rib repair with chest wall stabilization (CWS) techniques that are safer, easier to perform, and more efficient. Recent consensus statements have sought to define the indications and contraindications, as well as the when, the how, and the technical details of CWS. Repair should be considered for patients who have three or more displaced rib fractures or a flail chest, whether or not mechanical ventilation is required. Additional candidates include patients who fail non-operative management irrespective of fracture pattern and those with rib fractures who need thoracic procedures for other reasons. Traditionally, unstable spine fracture and severe traumatic brain injury are definite contraindications. Pulmonary contusion’s role in the decision to perform CWS remains controversial. A range of rib-specific plating systems are now commercially available. PMID:29744222

  3. [Treatment of conmminuted patellar fractures with internal Ni-Ti patellar concentrator and tension bind wire fixation].

    PubMed

    Tan, Hong-lie; Qian, Chen; Zhao, Jin-kun; Shi, Yan; Zhou, Qi

    2009-02-01

    To study the clinical efficacy of the treatment of comminuted patellar fractures with internal NiTi-Patellar concentrator and tension bind wire fixation. From March 2004 to June 2007, 38 cases of fresh comminuted patellar fractures were treated with internal NiTi-Patellar concentrator and tension bind wire fixation. There were 25 males and 13 females,ranging from 21 to 64 years (mean 42.5 years). All were comminuted fractures with displacement, 16 cases were 3 fragments, 14 cases were 4 fragments, 8 cases were 5 fragments. There were other fractures in 8 cases. During followed-up, knee function and complications were evaluated. All patients were followed up for 8 to 24 months (mean 15 months) and obtained complete bone union. No case of implant was loosening and fragment displacement, traumatic arthritis occured in 2 cases. Under Lysholm & Gillquist score, the results were excellent in 17 cases, good in 19, fair in 2. Internal Ni-Ti-Patellar concentrator and tension bind wire fixation is one of the ideal methods for the treatment of comminuted patellar fracture, which could provide satisfied reduction, reliable fixation and good functional recovery.

  4. [Reconstruction and balance of soft tissue in hemi-shoulder replacement for patients with four-part fracture of the proximal humerus].

    PubMed

    Wu, Xing; Lou, Lie-ming; Chen, Zheng-rong; Zhang, Guang-jian

    2008-10-01

    To explore the effective skills of reconstruction and balance of soft tissue in hemi-shoulder replacement for patients with four-part fracture of the proximal humerus in order to avoid postoperative complications of joint instability and great tubercle displacement. From June 2002 to June 2006, 25 patients with Neer four-part fracture of the proximal humerus were adopted in the study which included 15 females and 10 males, with the mean age of 66 years (ranged from 56 years to 80 years). They were treated with humeral head replacement and should joint reparation simultaneously by modified operation approach and reconstruction and balance skills of soft tissue. The mean duration of follow-up was 2.3 years (ranged from 1 to 4.5 years). No infection, nerve damage and prosthesis loosing were found in all cases. Two cases of infra-forward dislocation or subluxation occurred due to affected limb placed on abduction splint postoperatively. One case occurred prosthesis upward displacement due to early active abduction exercise but no complains. Neither joint instability nor displacement and malunion of great tubercle were found in other patients. According to Neer scoring system, 6 cases were rated as excellent, 15 as good and 5 as fair. The good and excellent rate was 84%. In hemi-shoulder replacement for patients with Neer four-part fracture the modified operation approach and reconstruction and balance of soft tissue skills combined with rational rehabilitation exercise can prevent postoperative shoulder joint instability and displacement and malunion of great tubercle.

  5. Surgical management of coracoid fractures: technical tricks and clinical experience.

    PubMed

    Hill, Brian W; Jacobson, Aaron R; Anavian, Jack; Cole, Peter A

    2014-05-01

    The coracoid process plays a pivotal role in the foundation of the coracoacromial arch and in cases of displaced fractures; surgical management may be warranted to avoid functional compromise or impingement. A direct approach through Langer's lines allows for easy exposure and direct visualization for an anatomic reduction of simple fractures through the shaft or base of the coracoid. An anterior approach for fractures that extend into the superior glenoid fossa allows for direct exposure to obtain an anatomic articular reduction and indirect reduction of the coracoid fracture. In cases where a complex glenoid or scapula neck/body fracture is being addressed simultaneously either a posterior Judet approach can be used with an indirect reduction method or a separate anterior approach must be combined to address it if not in continuity with the superior scapular segment. Implant selection, primarily interfragmentary screws or a buttress plate, should be based on the size of the fragment, the degree of comminution, and the degree of articular involvement to ensure adequate stabilization. The purpose of this manuscript was to describe a stepwise approach to the surgical management of displaced coracoid fractures, describe surgical tips and techniques, and to present the clinical outcomes in 22 patients after surgical treatment with this approach.

  6. Management of proximal humeral fractures in the nineteenth century: an historical review of preradiographic sources.

    PubMed

    Brorson, Stig

    2011-04-01

    The diagnosis and treatment of fractures of the proximal humerus have troubled patients and medical practitioners since antiquity. Preradiographic diagnosis relied on surface anatomy, pain localization, crepitus, and impaired function. During the nineteenth century, a more thorough understanding of the pathoanatomy and pathophysiology of proximal humeral fractures was obtained, and new methods of reduction and bandaging were developed. I reviewed nineteenth-century principles of (1) diagnosis, (2) classification, (3) reduction, (4) bandaging, and (5) concepts of displacement in fractures of the proximal humerus. A narrative review of nineteenth-century surgical texts is presented. Sources were identified by searching bibliographic databases, orthopaedic sourcebooks, textbooks in medical history, and a subsequent hand search. Substantial progress in understanding fractures of the proximal humerus is found in nineteenth-century textbooks. A rational approach to understanding fractures of the proximal humerus was made possible by an appreciation of the underlying functional anatomy and subsequent pathoanatomy. Thus, new principles of diagnosis, pathoanatomic classifications, modified methods of reduction, functional bandaging, and advanced concepts of displacement were proposed, challenging the classic management adhered to for more than 2000 years. The principles for modern pathoanatomic and pathophysiologic understanding of proximal humeral fractures and the principles for classification, nonsurgical treatment, and bandaging were established in the preradiographic era.

  7. A numerical approach for assessing effects of shear on equivalent permeability and nonlinear flow characteristics of 2-D fracture networks

    NASA Astrophysics Data System (ADS)

    Liu, Richeng; Li, Bo; Jiang, Yujing; Yu, Liyuan

    2018-01-01

    Hydro-mechanical properties of rock fractures are core issues for many geoscience and geo-engineering practices. Previous experimental and numerical studies have revealed that shear processes could greatly enhance the permeability of single rock fractures, yet the shear effects on hydraulic properties of fractured rock masses have received little attention. In most previous fracture network models, single fractures are typically presumed to be formed by parallel plates and flow is presumed to obey the cubic law. However, related studies have suggested that the parallel plate model cannot realistically represent the surface characters of natural rock fractures, and the relationship between flow rate and pressure drop will no longer be linear at sufficiently large Reynolds numbers. In the present study, a numerical approach was established to assess the effects of shear on the hydraulic properties of 2-D discrete fracture networks (DFNs) in both linear and nonlinear regimes. DFNs considering fracture surface roughness and variation of aperture in space were generated using an originally developed code DFNGEN. Numerical simulations by solving Navier-Stokes equations were performed to simulate the fluid flow through these DFNs. A fracture that cuts through each model was sheared and by varying the shear and normal displacements, effects of shear on equivalent permeability and nonlinear flow characteristics of DFNs were estimated. The results show that the critical condition of quantifying the transition from a linear flow regime to a nonlinear flow regime is: 10-4 〈 J < 10-3, where J is the hydraulic gradient. When the fluid flow is in a linear regime (i.e., J < 10-4), the relative deviation of equivalent permeability induced by shear, δ2, is linearly correlated with J with small variations, while for fluid flow in the nonlinear regime (J 〉 10-3), δ2 is nonlinearly correlated with J. A shear process would reduce the equivalent permeability significantly in the orientation perpendicular to the sheared fracture as much as 53.86% when J = 1, shear displacement Ds = 7 mm, and normal displacement Dn = 1 mm. By fitting the calculated results, the mathematical expression for δ2 is established to help choose proper governing equations when solving fluid flow problems in fracture networks.

  8. Multi-scale fracture networks within layered shallow water tight carbonates

    NASA Astrophysics Data System (ADS)

    Panza, Elisa; Agosta, Fabrizio; Rustichelli, Andrea; Vinciguerra, Sergio; Zambrano, Miller; Prosser, Giacomo; Tondi, Emanuele

    2015-04-01

    The work is aimed at deciphering the contribution of background deformation and persistent fracture zones on the fluid flow properties of tight platform carbonates. Taking advantage of 3D exposures present in the Murge area of southern Italy, the fracture networks crosscutting at different scales the layered Cretaceous limestone of the Altamura Fm. were analyzed. The rock multi-layer is characterized by 10's of cm-thick, sub-horizontal, laterally continuous carbonate beds. Each bed commonly represents a shallowing-upward peritidal cycle made up of homogeneous micritic limestones grading upward to cm-thick stromatolitic limestones and/or fenestral limestones. The bed interfaces are formed by sharp maximum flooding surfaces. Porosity measurements carried out on 40 limestone samples collected from a single carbonate bed show values ranging between 0,5% and 5,5%. Background deformation includes both stratabound and non-stratabound fractures. The former elements consist of bed-perpendicular joints and sheared joints, which are confined within a single bed and often displace small, bed-parallel stylolites. Non-stratabound fractures consist of incipient, cm offset, sub-vertical strike-slip faults, which crosscut the bed interfaces. The aforementioned elements are often confined within individual bed-packages, which are identified by presence of pronounced surfaces locally marked by veneers of reddish clayey paleosoils. Persistent fracture zones consist of 10's of m-high, 10's of cm-offset strike-slip faults that offset the bed-package interfaces and are confined within individual bed-packages association. Laterally discontinuous, cm- to a few m-thick paleokarstic breccia levels separate the different bed-packages associations. Persistent fracture zones include asymmetric fractured damage zones and mm-thick veneers of discontinuous fault rocks. The fracture networks that pervasively crosscut the study limestone multi-layer are investigated by mean of scanline and scanarea methodologies. The dimensional, spatial and scaling properties of both stratabound and non-stratabound fractures are documented along single beds and bed-packages, respectively. Persistent fracture zones are studied from individual bed-package associations. By computing the intensity, height distribution, aspect ratio, aperture of each fracture/fault set, DFN (Discrete Fracture Network) models are built for the aforementioned different scales of observation. DFN models of single beds and bed-packages include stratabound and non-stratabound fractures. Differently, the DFN model of a bed-packages association also includes persistent fracture zones and related damage zones. To check the results of our computations, we also build up a smaller scale, 1m3 geocellular volume in which fractures are inserted one at time in the model. All DFN models do not include the matrix porosity. Porosity and 3D permeability (Kx, Ky, Kz) values are obtained as outputs of the DFN models. The results are consistent with the most prominet set of non-stratabound fractures being the major control on the petrophysical properties of both single beds and bed-packages. As expected, the persistent fractures zones strongly affect both porosity and permeability of the bed-packages association. The results of ongoing laboratory analyses on representative limestone samples not only will provide a quantitative assessment of the physical properties of the matrix in terms of porosity and permeability, but also will shed new light on the geometry, density and anisotropy of microfractures and their role on fluid flow properties.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad Ghassemi

    Geothermal energy is recovered by circulating water through heat exchange areas within a hot rock mass. Geothermal reservoir rock masses generally consist of igneous and metamorphic rocks that have low matrix permeability. Therefore, cracks and fractures play a significant role in extraction of geothermal energy by providing the major pathways for fluid flow and heat exchange. Therefore, knowledge of the conditions leading to formation of fractures and fracture networks is of paramount importance. Furthermore, in the absence of natural fractures or adequate connectivity, artificial fractures are created in the reservoir using hydraulic fracturing. Multiple fractures are preferred because of themore » large size necessary when using only a single fracture. Although the basic idea is rather simple, hydraulic fracturing is a complex process involving interactions of high pressure fluid injections with a stressed hot rock mass, mechanical interaction of induced fractures with existing natural fractures, and the spatial and temporal variations of in-situ stress. As a result, it is necessary to develop tools that can be used to study these interactions as an integral part of a comprehensive approach to geothermal reservoir development, particularly enhanced geothermal systems. In response to this need we have developed advanced poro-thermo-chemo-mechanical fracture models for rock fracture research in support of EGS design. The fracture propagation models are based on a regular displacement discontinuity formulation. The fracture propagation studies include modeling interaction of induced fractures. In addition to the fracture propagation studies, two-dimensional solution algorithms have been developed and used to estimate the impact of pro-thermo-chemical processes on fracture permeability and reservoir pressure. Fracture permeability variation is studied using a coupled thermo-chemical model with quartz reaction kinetics. The model is applied to study quartz precipitation/dissolution, as well as the variation in fracture aperture and pressure. Also, a three-dimensional model of injection/extraction has been developed to consider the impact poro- and thermoelastic stresses on fracture slip and injection pressure. These investigations shed light on the processes involved in the observed phenomenon of injection pressure variation (e.g., in Coso), and allow the assessment of the potential of thermal and chemical stimulation strategies.« less

  10. Calcaneal apophyseal avulsion fracture.

    PubMed

    Imai, Yuuki; Kitano, Toshio; Nakagawa, Keisuke; Takaoka, Kunio

    2007-07-01

    Isolated fracture of the calcaneal apophysis is a rare injury in children and adolescents. In this study, we report on a case of a displaced calcaneal apophyseal avulsion fracture in a child treated with open reduction and internal fixation, as well as a review of the literature. A 9-year-old female child presented to the senior surgeon complaining of acute heel pain after a gymnastic injury. She was diagnosed with a displaced, isolated fracture of the proximal calcaneal apophysis for which she underwent open reduction and internal fixation. On the magnetic resonance imaging (MRI) examination, we could diagnose that her injury was not chronic but acute because there was no change of intensity in the metaphyseal area. A combination of bioabsorbable suture tacks and pins was used to anatomically fix the fragment using the tension band wiring technique. At 2 years and 6 months follow-up, she had full range of motion, complete return of strength. We report here on the successful surgical treatment and the first case evaluated by MRI of an avulsion fracture of the calcaneal apophysis in a child.

  11. The effects of axial displacement on fracture callus morphology and MSC homing depend on the timing of application.

    PubMed

    Weaver, Aaron S; Su, Yu-Ping; Begun, Dana L; Miller, Joshua D; Alford, Andrea I; Goldstein, Steven A

    2010-07-01

    The local mechanical environment and the availability of mesenchymal stem cells (MSC) have both been shown to be important factors in bone fracture healing. This study was designed to investigate how the timing of an applied axial displacement across a healing fracture affects callus properties as well as the migration of systemically introduced MSC. Bilateral osteotomies were created in male, Sprague-Dawley rats. Exogenous MSC were injected via the tail vein, and a controlled micro-motion was applied to one defect starting 0, 3, 10, or 24 days after surgery. The results showed that fractures stimulated 10 days after surgery had more mineral, less cartilage, and greater mechanical properties at 48 days than other groups. Populations of MSC were found in osteotomies 48 days after surgery, with the exception of the group that was stimulated 10 days after surgery. These results demonstrate that the timing of mechanical stimulation affects the physical properties of the callus and the migration of MSC to the fracture site. Published by Elsevier Inc.

  12. Study of fracture toughness of ZrO2 ceramics

    NASA Astrophysics Data System (ADS)

    Deryugin, Yevgeny; Narkevich, Natalya; Vlasov, Ilya; Panin, Victor; Danilenko, Igor; Schmauder, Siegfried

    2017-12-01

    The fracture toughness characteristics of ZrO2ceramics were determined experimentally using an original technique of wedging small-sized chevron notch specimens developed at the Institute of Strength Physics and Materials Science SB RAS (Russia) in the laboratory of physical mesomechanics of materials and non-destructive testing. Measurements have shown that inelastic displacements can be more than 22% of the total displacement of the consoles by the time of the specimen failure. The effect of the Y2O3 stabilizer on the critical stress intensity factor KIc was verified. It was shown that an increase in the Y2O3 stabilizer content from 3 to 8% significantly decreases the fracture toughness. The stress intensity factor KIc falls within the range from 5.7 to 2.35 MPa m1/2.

  13. The chopstick-noodle twist: an easy technique of percutaneous patellar fixation in minimally displaced patellar fractures.

    PubMed

    Muzaffar, Nasir; Ahmad, Nawaz; Ahmad, Aejaz; Ahmad, Nissar

    2012-01-01

    We report six cases of minimally displaced two-part patellar fractures with skin injury over the patella that were treated with percutaneous K wire fixation and compression applied using stainless steel (SS) wire. This technique makes it possible to perform early operative treatment in cases where unhealthy skin is not amenable to conventional tension band wiring. The technique employs two K wires inserted through the two fracture fragments under local or regional anaesthesia. They are then compressed using simple SS wire knots at the two ends - making it look like noodles at the end of two chopsticks. The fixation is subsequently augmented with a cylindrical plaster-of-Paris cast. The technique is simple, cheap and does not cause soft tissue injury.

  14. An unusual variety of simultaneous fracture dislocation pattern: medial swivel dislocation of talonavicular joint with displaced fractures of the fourth and fifth metatarsals.

    PubMed

    Inal, Sermet; Inal, Canan

    2013-01-01

    In published studies, a very rare, special type of Chopart dislocation termed a swivel dislocation has been reported. This injury is characterized by dislocation of the talonavicular joint, but the calcaneocuboid joint remains intact. The foot creates a typical rotational movement without inversion or eversion. The axis of rotation is the interosseous talocalcaneal ligament, which remains intact. We report the case of an 18-year-old male who had experienced a medial swivel dislocation of the talonavicular joint associated with displaced fractures of the fourth and fifth metatarsals. The occurrence, features, and method of treatment of this rare injury are presented. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective, randomized, multicenter study.

    PubMed

    Helling, Hanns-Joachim; Prokop, Axel; Schmid, Hans Ulrich; Nagel, Michael; Lilienthal, Jürgen; Rehm, Klaus Emil

    2006-01-01

    This multicenter, prospective, randomized study compares the use of biodegradable polylactide pins with standard metal mini-fragment implants for the treatment of displaced radial head fractures. It compares complication rates and clinical outcomes of both treatment methods. At 2 years, 135 (82%) of 164 patients were available for evaluation. Equivalence of treatment method was defined as a difference of 10% or less in the number of complication-free patients. Functional status was assessed by using the Broberg and Morrey Elbow Score and compared by an unpaired t test. Good or excellent clinical results were achieved by 92% (56/61) of the control patients and 96% (71/74) of the polylactide patients. The incidence of complication-free patients was 3.7% less in the polylactide group than in the control group. The 1-sided 95% confidence interval for the treatment difference between the 2 groups was more than -6.1%. Biodegradable polylactide pins have at least comparable outcomes as standard metal implants for the internal fixation of reconstructable displaced radial head fractures.

  16. Displaced intra-articular calcaneal fractures.

    PubMed

    Bajammal, Sohail; Tornetta, Paul; Sanders, David; Bhandari, Mohit

    2005-01-01

    Calcaneal fractures comprise 1 to 2 percent of all fractures. Approximately 75% of calcaneal fractures are intra-articular. The management of intra-articular calcaneal fractures remains controversial. Nonoperative treatment options include elevation, ice, early mobilization, and cyclic compression of the plantar arch. Operative treatment options include closed reduction and percutaneous pin fixation, open reduction and internal fixation, and arthrodesis. The effect of operative versus nonoperative treatment has been the focus of several comparative studies. This study was designed to determine the effect of operative treatment compared with nonoperative treatment on the rate of union, complications, and functional outcome after intra-articular calcaneal fracture in adults.

  17. Spontaneous displacement of olecranon fracture through geode salvaged by elbow replacement.

    PubMed

    Jaiswal, Anuj; Thakur, Raman; Relwani, Jaikumar; Ogufere, Wallace

    2010-04-01

    We present a case of pathological fracture of olecranon through a giant geode. Fracture was initially undisplaced and was treated conservatively. It later progressed to a transolecranon dislocation as a result of a pseudarthrosis at the fracture site. The patient presented 4 years later when she developed symptoms of ulnar nerve palsy. She was treated by a total elbow arthroplasty with ulnar nerve transposition. The current report highlights this unusual case and reviews the relevant literature.

  18. Surgical Stabilization of Rib Fractures in a 6-Year-Old Child After Blunt Trauma.

    PubMed

    Abdelsattar, Zaid M; Ishitani, Michael B; Kim, Brian D

    2017-12-01

    When identified, rib fractures in children are associated with high-energy trauma, nonaccidental trauma, or both. Traditionally, the optimal management of rib fractures in children is supportive care. In this case report, we present a 6-year-old boy who underwent surgical rib fixation for multiple displaced and comminuted rib fractures after being stepped on by a horse. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. The floating shoulder—-clinical and radiological results after intramedullary stabilization of the clavicle in cases with minor displacement of the scapular neck fracture.

    PubMed

    Izadpanah, Kaywan; Jaeger, Martin; Maier, Dirk; Kubosch, David; Hammer, Thorsten Oliver; Südkamp, Norbert P

    2012-02-01

    The aim of this study was to compare the clinical and radiologic results of titanium elastic nail (TEN) and plate osteosynthesis for treatment of clavicle fractures in patients with a floating shoulder injury. From 2000 to 2008, 16 patients with a floating shoulder injury (ipsilateral clavicle and minor displaced scapular neck fracture) were treated by isolated stabilization of the clavicle. The patients were treated with open reduction and plate osteosynthesis (group 1[G1]) or TEN osteosynthesis (group 2 [G2]). Both procedures were compared with regard to functional and radiologic outcome. Nine patients were treated with a plate osteosynthesis (G1) and seven with a TEN osteosynthesis (G2). The follow-up time was 35.7 months ± 16 months. There was no difference in functional outcome with regard to the intraindividual Constant score 83.9(G1) versus 86.7 (G2) or the American Shoulder and Elbow Surgeons score 79.1 (G1) versus 85.7 (G2). No significant postoperative dislocation of the glenopolar angle appeared. In the TEN-treated group, a clavicle shortening of 2.4 mm was observed. Subgroup analysis revealed significant greater shortening in type B and C compared with type A (OTA) clavicle fractures(4.7 mm vs. 0.8 mm). No clavicle shortening in the plate-treated group appeared. The treatment of floating shoulder injuries with TEN and plate osteosynthesis of the clavicle and nonoperative treatment of a minimally displaced glenoid neck fracture provide equal functional results. However, in type B and C (but not in type A) fractures of the clavicle, a shortening of 5 mm can be expected after titanium elastic nailing. Copyright ©2012 by Lippincott Williams & Wilkins

  20. Is Surgery for Displaced, Midshaft Clavicle Fractures in Adults Cost-Effective? Results Based on a Multicenter Randomized Controlled Trial

    PubMed Central

    2010-01-01

    Objectives To determine the cost-effectiveness of open reduction internal fixation (ORIF) of displaced, midshaft clavicle fractures in adults. Design Formal cost-effectiveness analysis based on a prospective, randomized controlled trial. Setting Eight hospitals in Canada (seven university affiliated and one community hospital) Patients/Participants 132 adults with acute, completely displaced, midshaft clavicle fractures Intervention Clavicle ORIF versus nonoperative treatment Main Outcome Measurements Utilities derived from SF-6D Results The base-case cost per quality adjusted life year (QALY) gained for ORIF was $65,000. Cost-effectiveness improved to $28,150/QALY gained when the functional benefit from ORIF was assumed to be permanent, with cost per QALY gained falling below $50,000 when the functional advantage persisted for 9.3 years or more. In other sensitivity analyses, the cost per QALY gained for ORIF fell below $50,000 when ORIF cost less than $10,465 (base case cost $13,668) or the long-term utility difference between nonoperative treatment and ORIF was greater than 0.034 (base-case difference 0.014). Short-term disutility associated with fracture healing also affected cost-effectiveness, with the cost per QALY gained for ORIF falling below $50,000 when the utility of a fracture treated nonoperatively prior to union was less than 0.617 (base-case utility 0.706) or when nonoperative treatment increased the time to union by 20 weeks (base-case difference 12 weeks). Conclusions The cost-effectiveness of ORIF after acute clavicle fracture depended on the durability of functional advantage for ORIF compared to nonoperative treatment. When functional benefits persisted for more than 9 years, ORIF had favorable value compared with many accepted health interventions. PMID:20577073

  1. Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model.

    PubMed

    Seeley, Mark A; Fabricant, Peter D; Lawrence, J Todd R

    2017-09-01

    Approximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement. A distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the realism of simulation. Eighteen participants consented to participate in the study (eight attending pediatric orthopaedic surgeons, six junior residents, four senior residents). The performances of junior residents (Postgraduate Year [PGY] 1-2), senior residents (PGY 3-5), and attending surgeons were compared using one-way ANOVA with Tukey's-adjusted pairwise comparisons. The majority of participants (15 of 18) felt that the model looked, felt, and moved like a human forearm. All participants strongly agreed that the model taught the basic steps of fracture reduction and should be implemented in orthopaedic training. Attending surgeons reduced fractures in less time than junior residents (60 ± 27 seconds versus 460 ± 62 seconds; mean difference, 400 seconds; 95% CI, 335-465 seconds; p < 0.001). Residual angulation was greater for junior residents when compared with attending surgeons on AP (7° ± 5° versus 0.7° ± 0.9°; mean difference, 6.3°; 95% CI, 3°-11°; p = 0.003) and lateral (27° ± 7° versus 7° ± 5°; mean difference, 20°; 95% CI, 13°-27°; p = 0.001) radiographs. Similarly, residual displacement was greater for junior residents than either senior residents (mean difference, 16 mm; 95% CI, 2-34 mm; p = 0.05) or attending surgeons (mean difference, 15 mm; 95% CI, 3-27 mm; p = 0.02) on lateral images. There were no differences identified in secondary performance variables (number of fluoroscopic images, casting time, and cast index) between groups. This is the first distal radius fracture reduction model to incorporate an elbow and shoulder and allow quantitative assessment of the fracture reduction. This simulator may be useful in an orthopaedic resident training program to help them reach a defined minimum level of competency. This simulator also could easily be integrated in other accreditation and training programs, including emergency medicine. Level II, therapeutic study.

  2. Mapping of hydraulic fractures from tiltmeter measurements

    NASA Astrophysics Data System (ADS)

    Lecampion, B.; Jeffrey, R.

    2003-12-01

    In considering the problem of inverse modeling of tiltmeter data for hydraulic fracture mapping, we address the issues of selecting the elastic model to represent the hydraulic fracture and limitations imposed by distance and fracture size on the information that can be recovered about the fracture. A tiltmeter measures, at its location, the changes in the surface inclination in two orthogonal directions. These inclinations are a direct measure of the horizontal gradient of the vertical component of the displacement field. Since advances in instrumentation in the last two decades, this type of apparatus have become extremely precise and can detect inclination changes down to a nanoradian. The simplicity of tiltmeter measurements has attracted interest not only in geophysics, but also in the petroleum industry. The idea of using tiltmeters to monitor hydraulic fractures can be traced back to the paper of Sun te{S} and is now a commercial service offered to the petroleum industry te{W}. However, the modeling and associated inverse problems required to analyze tiltmeter data raise difficult questions. The object(s) (fault, dyke, fracture) responsible for the recorded tilt are often modeled by finite Displacement Discontinuities, also called dislocation models. The validity of this type of model has been extensively discussed te{O,E} and many solutions for different configurations can be found in the literature. We show that it is possible to construct the solution for any type of dislocation model from the fundamental solution for an infinitesimal Displacement Discontinuity tensor. The eigenstrain theory te{M} is used to obtain this fundamental solution from the Green's function for the desired elastic domain (e.g. full or half space). Comparisons with known solutions demonstrate the flexibility of such method. We then focus on the problem of obtaining information about the orientation and size of an opening mode hydraulic fracture from the measured tilt field. One important problem is the identification of all the dimensions of the fracture model (length, width). The ability to obtain these parameters is controlled by limits, expressed in terms of the distance between the measurements and the fracture compared to the size of the fracture itself. The value of this ratio provides a condition that must be met before the fracture length-scales can be resolved. Determination of the fracture orientation is then investigated using a spatial Fourier Transform on the data set. This procedure highlights the requirement on the measurement array needed for a reliable identification: extension, number of tiltmeters, relative angle between the array and the fracture plane. \\begin{thebibliography}{1} \\bibitem{E} {Evans K.} \

  3. On the derivation of coseismic displacement fields using differential radar interferometry: The Landers earthquake

    NASA Technical Reports Server (NTRS)

    Zebker, Howard A.; Rosen, Paul A.; Goldstein, Richard M.; Gabriel, Andrew; Werner, Charles L.

    1994-01-01

    We present a map of the coseimic displacement field resulting from the Landers, California, June 28, 1992, earthquake derived using data acquired from an orbiting high-resolution radar system. We achieve results more accurate than previous space studies and similar in accuracy to those obtained by conventional field survey techniques. Data from the ERS 1 synthetic aperture radar instrument acquired in April, July, and August 1992 are used to generate a high-resolution, wide area map of the displacements. The data represent the motion in the direction of the radar line of sight to centimeter level precision of each 30-m resolution element in a 113 km by 90 km image. Our coseismic displacement contour map gives a lobed pattern consistent with theoretical models of the displacement field from the earthquake. Fine structure observed as displacement tiling in regions several kilometers from the fault appears to be the result of local surface fracturing. Comparison of these data with Global Positioning System and electronic distance measurement survey data yield a correlation of 0.96; thus the radar measurements are a means to extend the point measurements acquired by traditional techniques to an area map format. The technique we use is (1) more automatic, (2) more precise, and (3) better validated than previous similar applications of differential radar interferometry. Since we require only remotely sensed satellite data with no additioanl requirements for ancillary information. the technique is well suited for global seismic monitoring and analysis.

  4. Sonic logging for detecting the excavation disturbed and fracture zones

    NASA Astrophysics Data System (ADS)

    Lin, Y. C.; Chang, Y. F.; Liu, J. W.; Tseng, C. W.

    2017-12-01

    This study presents a new sonic logging method to detect the excavation disturbed zone (EDZ) and fracture zones in a tunnel. The EDZ is a weak rock zone where its properties and conditions have been changed by excavation, which results such as fracturing, stress redistribution and desaturation in this zone. Thus, the EDZ is considered as a physically less stable and could form a continuous and high-permeable pathway for groundwater flow. Since EDZ and fracture zone have the potential of affecting the safety of the underground openings and repository performance, many studies were conducted to characterize the EDZ and fracture zone by different methods, such as the rock mass displacements and strain measurements, seismic refraction survey, seismic tomography and hydraulic test, etc. In this study, we designed a new sonic logging method to explore the EDZ and fracture zone in a tunnel at eastern Taiwan. A high power and high frequency sonic system was set up which includes a two hydrophones pitch-catch technique with a common-offset immersed in water-filled uncased wells and producing a 20 KHz sound to scan the well rock. Four dominant sonic events were observed in the measurements, they are refracted P- and S-wave along the well rock, direct water wave and the reverberation in the well water. Thus the measured P- and S-wave velocities, the signal-to-noise ratio of the refraction and the amplitudes of reverberation along the well rock were used as indexes to determine the EDZ and fracture zone. Comparing these indexes with core samples shows that significant changes in the indexes are consistent with the EDZ and fracture zone. Thus, the EDZ and fracture zone can be detected by this new sonic method conclusively.

  5. Micromechanical predictions of crack propagation and fracture energy in a single fiber boron/aluminum model composite

    NASA Technical Reports Server (NTRS)

    Adams, D. F.; Mahishi, J. M.

    1982-01-01

    The axisymmetric finite element model and associated computer program developed for the analysis of crack propagation in a composite consisting of a single broken fiber in an annular sheath of matrix material was extended to include a constant displacement boundary condition during an increment of crack propagation. The constant displacement condition permits the growth of a stable crack, as opposed to the catastropic failure in an earlier version. The finite element model was refined to respond more accurately to the high stresses and steep stress gradients near the broken fiber end. The accuracy and effectiveness of the conventional constant strain axisymmetric element for crack problems was established by solving the classical problem of a penny-shaped crack in a thick cylindrical rod under axial tension. The stress intensity factors predicted by the present finite element model are compared with existing continuum results.

  6. Reoperation following open reduction and plate fixation of displaced mid-shaft clavicle fractures.

    PubMed

    Ashman, Bradley D; Slobogean, Gerard P; Stone, Trevor B; Viskontas, Darius G; Moola, Farhad O; Perey, Bertrand H; Boyer, Dory S; McCormack, Robert G

    2014-10-01

    Operative fixation of displaced, mid-shaft clavicle fractures has become an increasingly common practice. With this emerging trend, data describing patient outcomes with longer follow-up are necessary. We retrospectively reviewed the medical records of subjects treated with plate fixation for displaced mid-shaft clavicle fractures from 2003 to 2009 at a Level I trauma hospital. All subjects were greater than 12 months post-index surgery. Treatment involved ORIF with either a low-contact dynamic compression plate (LCDC) or a contoured plate (pre-contoured or pelvic reconstruction plate). Our primary outcome was reoperation for any indication. 143 subjects were included. The mean age was 36 ± 14 years and the mean time to reoperation or chart review was 33 months. Contoured plates were used in 64% of cases and LCDC plates were used in the remaining subjects. Twenty-nine subjects (20%) underwent reoperation: 23.5% of subjects treated with LCDC plates and 18.5% of subjects treated with contoured plates (p=0.52). Indications for reoperation included implant irritation (n=25), implant failure (n=2), and non-union (n=2). There was near statistically significant association with reoperation and female gender (p=0.05) but no association between reoperation and age (p=0.14), fracture class (p=0.53), plate type (p=0.49), or plate location (p=0.93). The mean QuickDASH score for the population surveyed was 8.8 (5.5-12.1; 95% CI) with near statistically significant and clinically relevant difference between those considering reoperation and those not 22.3 (8.6-36.0; 95% CI) versus 6.7 (3.6-9.8; 95% CI). This study represents a large series of displaced clavicle fractures treated with open reduction and plate fixation. Reoperation following plate fixation is relatively common, but primarily due to implant irritation. No difference in reoperation rates between plate types or location could be detected in our current sample size. Also, excellent functional outcomes continue to be observed several years after clavicle fracture fixation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Effect of fragmentary displacement and morphology in the treatment of comminuted femoral shaft fractures with an intramedullary nail.

    PubMed

    Lin, Shih-Jie; Chen, Chi-Lung; Peng, Kuo-Ti; Hsu, Wei-Hsiu

    2014-04-01

    Our study aimed to determine whether the displacement and morphology of a fragment in femur fracture with Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association/32-B/32-C (AO/OTA/32-B/32-C) classification affect the outcomes following closed reduction and internal fixation with an interlocking nail. This was a retrospective study. The study was conducted at a Level III trauma centre. A total of 50 consecutive patients presenting femoral shaft fracture with AO/OTA-type 32-B/32-C were included in the present study. Patients were divided into two groups according to the displacement of the fragments. In the large displacement group, patients were further subgrouped according to whether a reversed morphology of the fragment was present. The radiographic union score of femur (RUSF), the mean union time and the re-operation rate were assessed. The union rate of small- and large-gap groups at 12 months postoperatively was 75.9% and 21.1%, respectively (p=0.000). The mean union time of those union cases in these two groups was 7.8 and 13.0 months, respectively (p=0.000). The union rate of the non-reversed and reversed groups at 12 months postoperatively was 30% and 11.1%, respectively (p=0.179). The mean RUSF at 12 months in the non-reversed and reversed groups was 8.8 and 8.3, respectively (p=0.590). However, we found that patients presenting a reversed fragment had an increased risk of more than one re-operation (p=0.030). A fragmentary displacement of >1cm in AO/OTA-type 32-B/32-C femoral shaft fracture after nailing affected bone healing. Among the large-gap group patients, an unreduced reverse fragment presented a negative prognostic factor for re-operation. Prognostic level III. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Constitutive relationships and physical basis of fault strength due to flash heating

    USGS Publications Warehouse

    Beeler, N.M.; Tullis, T.E.; Goldsby, D.L.

    2008-01-01

    We develop a model of fault strength loss resulting from phase change at asperity contacts due to flash heating that considers a distribution of contact sizes and nonsteady state evolution of fault strength with displacement. Laboratory faulting experiments conducted at high sliding velocities, which show dramatic strength reduction below the threshold for bulk melting, are well fit by the model. The predicted slip speed for the onset of weakening is in the range of 0.05 to 2 m/s, qualitatively consistent with the limited published observations. For this model, earthquake stress drops and effective shear fracture energy should be linearly pressure-dependent, whereas the onset speed may be pressure-independent or weakly pressure-dependent. On the basis of the theory, flash weakening is expected to produce large dynamic stress drops, small effective shear fracture energy, and undershoot. Estimates of the threshold slip speed, stress drop, and fracture energy are uncertain due to poor knowledge of the average ontact dimension, shear zone thickness and gouge particle size at seismogenic depths. Copyright 2008 by the American Geophysical Union.

  9. Effect of Augmentation Material Stiffness on Adjacent Vertebrae after Osteoporotic Vertebroplasty Using Finite Element Analysis with Different Loading Methods.

    PubMed

    Cho, Ah-Reum; Cho, Sang-Bong; Lee, Jae-Ho; Kim, Kyung-Hoon

    2015-11-01

    Vertebroplasty is an effective treatment for osteoporotic vertebral fractures, which are one of the most common fractures associated with osteoporosis. However, clinical observation has shown that the risk of adjacent vertebral body fractures may increase after vertebroplasty. The mechanism underlying adjacent vertebral body fracture after vertebroplasty is not clear; excessive stiffness resulting from polymethyl methacrylate has been suspected as an important mechanism. The aim of our study was to compare the effects of bone cement stiffness on adjacent vertebrae after osteoporotic vertebroplasty under load-controlled versus displacement-controlled conditions. An experimental computer study using a finite element analysis. Medical research institute, university hospital, Korean. A three-dimensional digital anatomic model of L1/2 bone structure was reconstructed from human computed tomographic images. The reconstructed three-dimensional geometry was processed for finite element analysis such as meshing elements and applying material properties. Two boundary conditions, load-controlled and displacement-controlled methods, were applied to each of 5 deformation modes: compression, flexion, extension, lateral bending, and torsion. The adjacent L1 vertebra, irrespective of augmentation, revealed nearly similar maximum von Mises stresses under the load-controlled condition. However, for the displacement-controlled condition, the maximum von Mises stresses in the cortical bone and inferior endplate of the adjacent L1 vertebra increased significantly after cement augmentation. This increase was more significant than that with stiffer bone cement under all modes, except the torsion mode. The finite element model was simplified, excluding muscular forces and incorporating a large volume of bone cement, to more clearly demonstrate effects of bone cement stiffness on adjacent vertebrae after vertebroplasty. Excessive stiffness of augmented bone cement increases the risk of adjacent vertebral fractures after vertebroplasty in an osteoporotic finite element model. This result was most prominently observed using the displacement-controlled method.

  10. Clinical and financial comparison of operative and nonoperative treatment of displaced clavicle fractures.

    PubMed

    Althausen, Peter L; Shannon, Steven; Lu, Minggen; O'Mara, Timothy J; Bray, Timothy J

    2013-05-01

    Surgical stabilization of displaced clavicle fractures was once considered to have rare indications. Our purpose was to present the clinical and economic effects of surgical management using data collected from operative and nonoperative patients. Our fracture database was queried from January 1, 2005, to January 1, 2010, identifying 204 patients with displaced midclavicular fractures. Radiographs and charts were reviewed, and questionnaires were distributed. Operative patients had less chronic pain (6.1% vs 25.3%), less cosmetic deformity (18.2% vs 32.5%), less weakness (10.6% vs 33.7%), less loss of motion (15.2% vs 31.3%), and fewer nonunions (0% vs 4.8%). Operative patients missed fewer days of work (8.4 days vs 35.2 days) and required less assistance (3 days vs 7 days) for care at home. Mean income lost was $321.69 versus $10,506.25. Operative patients had a mean emergency department bill of $2,060.51 versus $1,871.92 and had a mean hospital bill of $8,520.30 versus $3,692.65, and anesthesia charges averaged $946.11. Operative patients required less physical therapy, and the mean physical therapy cost was $971.76 versus $1,820. Nonoperative patients required more pain medication ($43.22 vs $45.98). Overall, the cost was $12,976.94 for operative patients and $18,068.27 for nonoperative patients. Patients with displaced clavicle fractures benefit clinically and financially from stabilization. They have less chronic pain, less deformity, less weakness, and better range of motion. They return to work sooner, take less pain medication, and require less physical therapy. Their initial hospital bill is higher because of surgical charges but is balanced by less income loss, resulting in a cost savings of $5,091.33 in operative patients. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. Three-dimensional finite element analysis and comparison of a new intramedullary fixation with interlocking intramedullary nail.

    PubMed

    Liu, Chang-cheng; Xing, Wen-zhao; Zhang, Ya-xing; Pan, Zheng-hua; Feng, Wen-ling

    2015-03-01

    This study was set to introduce a new intramedullary fixation, explore its biomechanical properties, and provide guidance for further biomechanical experiments. With the help of CT scans and finite element modeling software, finite element model was established for a new intramedullary fixation and intramedullary nailing of femoral shaft fractures in a volunteer adult. By finite element analysis software ANSYS 10.0, we conducted 235-2,100 N axial load, 200-1,000 N bending loads and 2-15 Nm torsional loading, respectively, and analyzed maximum stress distribution, size, and displacement of the fracture fragments of the femur and intramedullary nail. During the loading process, the maximum stress of our new intramedullary fixation were within the normal range, and the displacement of the fracture fragments was less than 1 mm. Our new intramedullary fixation exhibited mechanical reliability and unique advantages of anti-rotation, which provides effective supports during fracture recovery.

  12. Imaging in traumatic mandibular fractures

    PubMed Central

    Gemal, Hugo; Reed, Duncan

    2017-01-01

    A fracture of the mandible is a common trauma presentation amongst young males and represents one of the most frequently encountered fractured bones within the viscerocranium. Historically, assault was the dominant contributing factor but now due to the increased number of vehicles used per capita, motor vehicle accidents are the primary cause. Mandibular fractures can be classified anatomically, by dentition, by muscle group and by severity. The fracture may also be closed, open, comminuted, displaced or pathological. It is important that the imaging modality used identifies the classification as this will decide definitive treatment. X-ray projections have typically been used to detect a mandibular fracture, but are limited to an anteroposterior (AP), lateral and oblique view in an unstable trauma patient. These views are inadequate to detail the level of fracture displacement and show poor detail of the condylar region. Computer tomography (CT) is the imaging modality of choice when assessing a traumatic mandibular injury and can demonstrate a 100% sensitivity in detecting a fracture. This is through use of a multidetector-row CT, which reduces motion blur and therefore produces accurate coronal and sagittal reconstructions. Furthermore, reconstructive three-dimensional CT images gained from planar views, allows a better understanding of the spatial relationship of the fracture with other anatomical landmarks. This ensures a better appreciation of the severity and classification of a mandibular fracture, which therefore influences operative planning. Ultrasound is another useful modality in detecting a mandibular fracture when the patient is too unstable to be transferred to a CT scanner. The sensitivity however is less in comparison to a CT series of images and provides limited detail on the fracture pattern. Magnetic resonance imaging demonstrates use in assessing soft tissue injury of the temporomandibular joint but this is unlikely to be of priority when initially assessing a trauma patient. PMID:28932703

  13. Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon's perspective.

    PubMed

    Wichlas, Florian; Tsitsilonis, Serafim; Kopf, Sebastian; Krapohl, Björn Dirk; Manegold, Sebastian

    2017-01-01

    Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius fractures were treated with open reduction and internal fixation through palmar, dorsal, and dorsopalmar approaches with 2.4 mm locking plates or underwent percutaneous fixation. The parameters that should replace the surgeon's analysis were the fractured palmar cortex, and the frontal and the sagittal split of the articular surface of the distal radius. Results: The palmar approach was used for 422 (84.4%) fractures, the dorsal approach for 39 (7.8%), and the combined dorsopalmar approach for 30 (6.0%). Nine (1.8%) fractures were treated percutaneously. The correlation between the fractured palmar cortex and the used palmar approach was moderate (r=0.464; p<0.0001). The correlation between the frontal split and the dorsal approach, including the dorsopalmar approach, was strong (r=0.715; p<0.0001). The sagittal split had only a weak correlation for the dorsal and dorsopalmar approach (r=0.300; p<0.0001). Discussion: The study shows that the surgical decision on the preferred approach is dictated through two simple factors, even in the case of complex fractures. Conclusion: When the palmar cortex is displaced in distal radius fractures, a palmar approach should be used. When there is a displaced frontal split of the articular surface, a dorsal approach should be used. When both are present, a dorsopalmar approach should be used. These two simple parameters could replace the surgeon's analysis for the surgical approach.

  14. On the Processing of Spalling Experiments. Part II: Identification of Concrete Fracture Energy in Dynamic Tension

    NASA Astrophysics Data System (ADS)

    Lukić, Bratislav B.; Saletti, Dominique; Forquin, Pascal

    2017-12-01

    This paper presents a second part of the study aimed at investigating the fracture behavior of concrete under high strain rate tensile loading. The experimental method together with the identified stress-strain response of three tests conducted on ordinary concrete have been presented in the paper entitled Part I (Forquin and Lukić in Journal of Dynamic Behavior of Materials, 2017. https://doi.org/10.1007/s40870-017-0135-1). In the present paper, Part II, the investigation is extended towards directly determining the specific fracture energy of each observed fracture zone by visualizing the dynamic cracking process with a temporal resolution of 1 µs. Having access to temporal displacement fields of the sample surface, it is possible to identify the fracture opening displacement (FOD) and the fracture opening velocity of any principle (open) and secondary (closed) fracture at each measurement instance, that may or may not lead to complete physical failure of the sample. Finally, the local Stress-FOD curves were obtained for each observed fracture zone, opposed to previous works where indirect measurements were used. The obtained results indicated a much lower specific fracture energy compared to the results often found in the literature. Furthermore, numerical simulations were performed with a damage law to evaluate the validity of the proposed experimental data processing and compare it to the most often used one in the previous works. The results showed that the present method can reliably predict the specific fracture energy needed to open one macro-fracture and suggested that indirect measurement techniques can lead to an overestimate of specific fracture energy due to the stringent assumption of linear elasticity up-to the peak and the inability of having access to the real post-peak change of axial stress.

  15. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].

    PubMed

    Zhang, J; Jiang, X Y; Huang, X W

    2016-06-18

    To investigate the clinical efficacy and outcomes of two separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella. From January 2013 to January 2015, 15 consecutive patients (mean age 54.5 years) with inferior pole fractures of the patella were retrospectively included in this study. All the patients underwent open reduction and internal fixation by separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire through longitudinal incision, 4.5 d (range: 3.1-5.9 d) after initial injury. A safety check for early knee range of motion was performed before wound closure. The complications including infection, nonunion, loss of fixation and any wire breakage or irritation from implant were recorded. Anteroposterior and lateral views of the knee joint obtained during the follow-up were used to assess bony union based on the time when the fracture line disappeared. At the time of the final outpatient follow up, functional evaluation of the knee joint was conducted by Bostman system. The follow-up time was 13.1 months (range: 12-19 months) after surgery on average, immediate motion without immobilization in all the cases was allowed and there was no case of reduction loss of the fracture and wire breakage. There was no case of irritation from the implant. At the final follow-up, the average range of motion (ROM) arc was 126.7° (range: 115°-140°), the average ROM lag versus contralateral healthy leg was 10.3° (range: 0°-35°). The mean Bostman score at the last follow-up was 28.9 (range: 27-30), and graded excellent in most cases. Two separate vertical wiring is an easy and effective method to reduce the displaced inferior pole fracture of patella. Augmentation of separate vertical wiring with tension band and Kirschner-wire plus cerclage wire in these patients provides enough strength to protected the early exercise of the knee joint and uneventful healing. By this surgical treatment, excellent results in knee function can be expected for cases of displaced inferior pole fractures of the patella.

  16. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    PubMed

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good outcome. However, a significantly lower rate of complications or better clinical outcome than that reported in the literature could not be found. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. An Integrated Tensorial Approach for Quantifying Porous, Fractured Rocks

    NASA Astrophysics Data System (ADS)

    Healy, David; Rizzo, Roberto; Harland, Sophie; Farrell, Natalie; Browning, John; Meredith, Phil; Mitchell, Tom; Bubeck, Alodie; Walker, Richard

    2017-04-01

    The patterns of fractures in deformed rocks are rarely uniform or random. Fracture orientations, sizes, shapes and spatial distributions often exhibit some kind of order. In detail, there may be relationships among the different fracture attributes e.g. small fractures dominated by one orientation, and larger fractures by another. These relationships are important because the mechanical (e.g. strength, anisotropy) and transport (e.g. fluids, heat) properties of rock depend on these fracture patterns and fracture attributes. Based on previously published work (Oda, Cowin, Sayers & Kachanov) this presentation describes an integrated tensorial approach to quantifying fracture networks and predicting the key properties of fractured rock: permeability and elasticity (and in turn, seismic velocities). Each of these properties can be represented as tensors, and these entities capture the essential 'directionality', or anisotropy of the property. In structural geology, we are familiar with using tensors for stress and strain, where these concepts incorporate volume averaging of many forces (in the case of the stress tensor), or many displacements (for the strain tensor), to produce more tractable and more computationally efficient quantities. It is conceptually attractive to formulate both the structure (the fracture network) and the structure-dependent properties (permeability, elasticity) in a consistent way with tensors of 2nd and 4th rank, as appropriate. Examples are provided to highlight the interdependence of the property tensors with the geometry of the fracture network. The fabric tensor (or orientation tensor of Scheidegger, Woodcock) describes the orientation distribution of fractures in the network. The crack tensor combines the fabric tensor (orientation distribution) with information about the fracture density and fracture size distribution. Changes to the fracture network, manifested in the values of the fabric and crack tensors, translate into changes in predicted permeability and elasticity (seismic velocity). Conversely, this implies that measured changes in any of the in situ properties or responses in the subsurface (e.g. permeability, seismic velocity) could be used to predict, or at least constrain, the fracture network. Explicitly linking the fracture network geometry to the permeability and elasticity (seismic velocity) through a tensorial formulation provides an exciting and efficient alternative to existing approaches.

  18. [Management of displaced radial neck fractures in children: elastic stable intramedullary nailing vs K-wire fixation].

    PubMed

    Wu, Quan-Zhou; Huang, Shu-Ming; Cai, Qi-Xun; Chu, Xu-Feng

    2017-01-25

    To compare the complications and clinical outcome of titanium elastic nail(TEN) versus K-wire fixation(KW) for the treatment of displaced radial neck fractures in children. From January 2009 to December 2014, 56 children with displaced radial neck fractures were studied retrospectively according to the inclusion criteria. Based on the different methods of internal fixation, patients were divided into two groups: titanium elastic nail (TEN group) and K-wire fixation (KW group). Among 25 patients(15 males and 11 females, aged from 3 to 12 years old with an average of 8.6±2.1) treated with TEN, 16 patients had type III fractures, 19 patients had type IV fractures according to Metaizeau-Judet modified classification; 20 patients were treated with closed reduction and 5 patients were treated with open reduction; the time from injury to treatment ranged from 1 to 8 days with an average of (3.6±1.7) days. Among 31 patients (20 males and 11 females, aged from 3 to 11 years old with an average of 9.1±1.9 years old) treated with KW, 19 patients had type III fractures, 12 patients had type IV fractures; 22 patients were treated with closed reduction, and 9 patients were treated with open reduction; the time from injury to treatment ranged from 2 to 7 days with an average of (3.7±1.5) days. No significant differences between two groups were found in general data. Operative time, hospitalization time, healing time of fracture, internal fixation time, postoperative complications and function recovery of the two groups were compared and evaluated. The average follow-up period of the patients was 22.1 months in TEN group(ranged, 16 to 48 months), and 21.9 months in KW group(ranged, 13 to 48 months). There were no significant differences between these 2 groups in follow-up duration, average hospitalization time and fracture healing time. The operation time, hospital costs and internal fixation time in TEN group were (56.6±11.8) min, (18 000±3 000) Yuan(RMB), (9.1±2.5) weeks respectively; and in KW group were(45.5±10.3) min, (8 000±1 000) Yuan(RMB), (4.8±1.6) weeks respectively, there were significant differences between two groups( P <0.05). Outcome scores according to Metaizeau and Tibone-Stoltz had no significant differences between two groups( P >0.05). There is no significant difference of therapeutic effects between TEN and KW for children with displaced radial neck fractures. Because the removal of TEN fixation requires the secondary anesthesia, and the TEN costs significantly more than KW, TEN still can't replace the traditional KW for the treatment of radial neck fracture in children.

  19. Internal architecture, permeability structure, and hydrologic significance of contrasting fault-zone types

    NASA Astrophysics Data System (ADS)

    Rawling, Geoffrey C.; Goodwin, Laurel B.; Wilson, John L.

    2001-01-01

    The Sand Hill fault is a steeply dipping, large-displacement normal fault that cuts poorly lithified Tertiary sediments of the Albuquerque basin, New Mexico, United States. The fault zone does not contain macroscopic fractures; the basic structural element is the deformation band. The fault core is composed of foliated clay flanked by structurally and lithologically heterogeneous mixed zones, in turn flanked by damage zones. Structures present within these fault-zone architectural elements are different from those in brittle faults formed in lithified sedimentary and crystalline rocks that do contain fractures. These differences are reflected in the permeability structure of the Sand Hill fault. Equivalent permeability calculations indicate that large-displacement faults in poorly lithified sediments have little potential to act as vertical-flow conduits and have a much greater effect on horizontal flow than faults with fractures.

  20. Neglected transport equations: extended Rankine-Hugoniot conditions and J -integrals for fracture

    NASA Astrophysics Data System (ADS)

    Davey, K.; Darvizeh, R.

    2016-09-01

    Transport equations in integral form are well established for analysis in continuum fluid dynamics but less so for solid mechanics. Four classical continuum mechanics transport equations exist, which describe the transport of mass, momentum, energy and entropy and thus describe the behaviour of density, velocity, temperature and disorder, respectively. However, one transport equation absent from the list is particularly pertinent to solid mechanics and that is a transport equation for movement, from which displacement is described. This paper introduces the fifth transport equation along with a transport equation for mechanical energy and explores some of the corollaries resulting from the existence of these equations. The general applicability of transport equations to discontinuous physics is discussed with particular focus on fracture mechanics. It is well established that bulk properties can be determined from transport equations by application of a control volume methodology. A control volume can be selected to be moving, stationary, mass tracking, part of, or enclosing the whole system domain. The flexibility of transport equations arises from their ability to tolerate discontinuities. It is insightful thus to explore the benefits derived from the displacement and mechanical energy transport equations, which are shown to be beneficial for capturing the physics of fracture arising from a displacement discontinuity. Extended forms of the Rankine-Hugoniot conditions for fracture are established along with extended forms of J -integrals.

  1. The Clavicle Trial: A Multicenter Randomized Controlled Trial Comparing Operative with Nonoperative Treatment of Displaced Midshaft Clavicle Fractures.

    PubMed

    Ahrens, Philip M; Garlick, Nicholas I; Barber, Julie; Tims, Emily M

    2017-08-16

    The treatment of displaced midshaft clavicle fractures remains controversial. We undertook a multicenter randomized controlled trial to compare effectiveness and safety between nonoperative management and ORIF (open reduction and internal fixation) for displaced midshaft clavicle fractures in adults. Three hundred and one eligible adult patients were randomized to 1 of the 2 treatment groups and followed at 6 weeks, 3 months, and 9 months after recruitment. The primary outcome was the rate of radiographically evident nonunion at 3 months following treatment. Secondary outcomes were the rate of radiographically evident nonunion at 9 months, limb function measured using the Constant-Murley Score and DASH (Disabilities of the Arm, Shoulder and Hand) score, and patient satisfaction. There was no difference in the proportion of patients with radiographic evidence of nonunion at 3 months between the operative (28%) and nonoperative (27%) groups, whereas at 9 months the proportion with nonunion was significantly lower (p < 0.001) in the operative group (0.8%) than in the nonoperative group (11%). The DASH and Constant-Murley scores and patient satisfaction were all significantly better in the operative group than in the nonoperative group at 6 weeks and 3 months. Although at 3 months there was no evidence that surgery had reduced the rate of nonunion of displaced midshaft clavicle fractures, at 9 months nonoperative treatment had led to a significantly higher nonunion rate (11% compared with <1%). The rate of secondary surgical intervention during the trial period was 12 (11%) of the 147 patients in the nonoperative group. ORIF is a safe and reliable intervention with superior early functional outcomes and should be considered for patients who sustain this common injury. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  2. The comparative biomechanics of the reinforced interdental crossover and the Stout loop composite splints for mandibular fracture repair in dogs.

    PubMed

    Kitshoff, A M; de Rooster, H; Ferreira, S M; Burger, D; Steenkamp, G

    2013-01-01

    To describe a new technique, the reinforced interdental crossover composite splint (RIC), for transverse mandibular fracture repair in dogs. This technique was compared biomechanically with the established reinforced interdental Stout loop composite splint (RIS) technique. Six pairs of mandibles from young adult small breed dogs were used for the study. Osteotomies were created in a standardized fashion and fixed with either RIC or RIS. All composite splint constructs were tested biomechanically with a cantilever bending force, using a single column testing machine at a rate of 2 mm/min. The time of application, amount of composite used, ultimate force, stiffness, total displacement, and total energy absorbed during displacement of the rostral mandibular segment were calculated and compared between the two groups. No significant difference was found when comparing the time of application of the RIC and the RIS techniques. All implants failed by either composite resin fracture over the region of the osteotomy or by fracture between the first and second molar followed by detachment of the resin from the lingual enamel surface of the first molar. Differences between the RIC and RIS in force (80.5 N ± 40.3 and 51.8 N ± 27.4. respectively) and stiffness (16.2 N/mm ± 4.4 and 10.1 N/mm ± 4.1 respectively) were significant (p = 0.03). However differences between the two techniques in displacement and total energy absorbed were not significant. In experimentally fractured mandibles of young adult dogs there is evidence that RIC is biomechanically similar to RIS.

  3. Midterm results of surgical treatment of displaced proximal humeral fractures in children.

    PubMed

    Pavone, Vito; de Cristo, Claudia; Cannavò, Luca; Testa, Gianluca; Buscema, Antonio; Condorelli, Giuseppe; Sessa, Giuseppe

    2016-07-01

    To analyse the clinical outcomes of 26 children treated surgically for displaced proximal humerus fracture. From January 2008 to December 2012, 26 children/adolescents (14 boys, 12 girls) were treated surgically for displaced fractures at the proximal extremity of the humerus. Ten were grade III and 16 were grade IV according to the Neer-Horowitz classification with a mean age of 12.8 ± 4.2 years. Twenty young patients were surgically treated with a closed reduction and direct percutaneous pinning; six required an open approach. To obtain a proper analysis, we compared the Costant scores with the contralateral shoulder (Δ Costant). The mean follow-up period was 34 months (range 10-55). Two grade IV patients showed a loss in the reduction after percutaneous treatment. This required open surgery with a plate and screws. On average, the treated fractures healed at 40 days. The mean Δ Costant score was 8.43 (range 2-22). There was a statistically significant improvement in the mean Δ Costant score in grade III patients. In grade IV patients, there was a significant improvement in the mean Δ Costant score in those treated with open surgery versus mini-invasive surgery. Our study shows excellent results with percutaneous k-wires. This closed surgery had success in these patients, and the excellent outcomes noted here lead us to prefer the mini-invasive surgical approach in NH grade III fractures. In grade IV, the best results were noted in patients treated with open surgery. We suggest an open approach for these patients. III.

  4. Geometrically Nonlinear Field Fracture Mechanics and Crack Nucleation, Application to Strain Localization Fields in Al-Cu-Li Aerospace Alloys.

    PubMed

    Gupta, Satyapriya; Taupin, Vincent; Fressengeas, Claude; Jrad, Mohamad

    2018-03-27

    The displacement discontinuity arising between crack surfaces is assigned to smooth densities of crystal defects referred to as disconnections, through the incompatibility of the distortion tensor. In a dual way, the disconnections are defined as line defects terminating surfaces where the displacement encounters a discontinuity. A conservation statement for the crack opening displacement provides a framework for disconnection dynamics in the form of transport laws. A similar methodology applied to the discontinuity of the plastic displacement due to dislocations results in the concurrent involvement of dislocation densities in the analysis. Non-linearity of the geometrical setting is assumed for defining the elastic distortion incompatibility in the presence of both dislocations and disconnections, as well as for their transport. Crack nucleation in the presence of thermally-activated fluctuations of the atomic order is shown to derive from this nonlinearity in elastic brittle materials, without any algorithmic rule or ad hoc material parameter. Digital image correlation techniques applied to the analysis of tensile tests on ductile Al-Cu-Li samples further demonstrate the ability of the disconnection density concept to capture crack nucleation and relate strain localization bands to consistent disconnection fields and to the eventual occurrence of complex and combined crack modes in these alloys.

  5. Tibial plateau fracture after primary anatomic double-bundle anterior cruciate ligament reconstruction: a case report.

    PubMed

    Gobbi, Alberto; Mahajan, Vivek; Karnatzikos, Georgios

    2011-05-01

    Tibial plateau fracture after primary anatomic double-bundle anterior cruciate ligament (ACL) reconstruction is rare. To our knowledge, this is the first case report of a tibial plateau fracture after primary anatomic double-bundle ACL reconstruction. In our patient the tibial plateau fracture occurred after a torsional injury to the involved extremity. The fracture occurred 4.5 years after the ACL reconstruction. The fracture was intra-articular Schatzker type IV and had a significant displacement. The patient was treated operatively by open reduction-internal fixation. He recovered well. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Effect of microstructure and notch root radius on fracture toughness of an aluminum metal matrix composite

    NASA Technical Reports Server (NTRS)

    Manoharan, M.; Lewandowski, J. J.

    1989-01-01

    Recent results on the effects of matrix aging condition (matrix temper) and notch root radius on the measured fracture toughness of a SiC particulate reinforced aluminum alloy are reviewed. Stress intensity factors at catastrophic fracture were obtained for both underaged and overaged composites reveal. The linear relation found between apparent fracture toughness and the square root of the notch root radius implies a linear dependence of the crack opening displacement on the notch root radius. The results suggest a strain controlled fracture process, and indicate that there are differences in the fracture micromechanisms of the two aging conditions.

  7. An unusual fracture of the talus in a snowboarder.

    PubMed

    Vlahovich, A Tanja; Mehin, Ramin; O'Brien, Peter J

    2005-08-01

    Fractures of the talus are uncommon. However, snow- boarding and skateboarding are 2 activities that are specifically associated with talus fractures. These patients sustain occult lateral talus process fractures that present as a severe ankle injury. The diagnosis is difficult because of subtle clinical and plain radiographic findings. Computed tomography is a very useful tool for the assessment of these injuries. Although the majority of these athletes have lateral sided talus fractures, there are variants. We present an unusual case of a displaced intra-articular fracture of the subtalar joint involving the middle articular facet of the talus with extension of the fracture into the talar head. This highlights the importance of carefully assessing snowboarders' "ankle injuries."

  8. [Anatomy of fractures of the inferior scapular angle].

    PubMed

    Bartoníček, J; Tuček, M; Malík, J

    2018-01-01

    The aim of this study is to describe the anatomy of fractures of the inferior angle and the adjacent part of the scapular body, based on 3D CT reconstructions. In a series of 375 scapular fractures, we identified a total of 20 fractures of the inferior angle of the scapular body (13 men, 7 women), with a mean patient age of 50 years (range 3373). In all fractures, 3D CT reconstructions were obtained, allowing an objective evaluation of the fracture pattern with a focus on the size and shape of the inferior angle fragment, propagation of the fracture line to the lateral and medial borders of the infraspinous part of the scapular body, fragment displacement and any additional fracture of the ipsilateral scapula and the shoulder girdle. We identified a total of 5 types of fracture involving the distal half of the infraspinous part of the scapular body. The first type, recorded in 5 cases, affected only the apex of the inferior angle, with a small part of the adjacent medial border. The second type, occurring in 4 cases, involved fractures separating the entire inferior angle. The third type, represented by 4 cases, was characterized by a fracture line starting medially close above the inferior angle and passing proximolaterally. The separated fragment had a shape of a big drop, carrying also the distal half of the lateral pillar in addition to the inferior angle. In the fourth type identified in 5 fractures, the separated fragment was formed both by the inferior angle and a variable part of the medial border. The fifth type, being by its nature a transition to the fracture of the infraspinous part of the body, was recorded in 2 cases, with the same V-shaped fragment. Fractures of the inferior angle and the adjacent part of the scapular body are groups of fractures differing from other infraspinous fractures of the scapular body. Although these fractures are highly variable in terms of shape, they have the same course of fracture line and the manner of displacement.Key words: scapula scapula fractures scapular body fractures inferior angle classification of scapular body fractures.

  9. Lateral X-ray for proximal femoral fractures - Is it really necessary?

    PubMed

    Riaz, Osman; Nisar, Sohail; Arshad, Rizwan; Vanker, Raees

    2016-10-01

    Historically routine work up of a patient with a proximal femoral fracture always included anterior-posterior (AP) and a lateral film of the hip. The aim was to define the role of the lateral X-ray in the assessment and surgical planning of proximal femur fractures. Radiographs of 320 consecutive patients with proximal femoral fractures who were admitted over a 12 months period were divided into lateral and AP views. Two blinded reviewers independently assessed the AP view alone and then the AP plus the lateral view. Fracture classification was noted for each X-ray and then compared with intraoperative diagnosis which was our study's gold standard. A 2 × 2 contingency square table and Pearson's x(2) test were used for statistical analysis. The rate of correct classification by the reviewers enhanced by the assessment of the lateral X-ray in addition to the AP view for intracapsular fractures (p = 0.018) but not for extracapsular fractures (p = 0.29). Operative management did not change for intracapsular fractures which appeared displaced on initial AP view after reviewing the lateral X-ray. The only advantage of obtaining a lateral view in intracapsular fracture was the detection of displacement were the fracture appeared to be undisplaced on initial AP view. This study provides statistical evidence that one view is adequate and safe for majority of proximal femoral fractures. The lateral radiograph should not be performed on a routine basis thus making considerable saving in time and money, and avoiding unnecessary radiation exposure and discomfort to the patient. Copyright © 2015 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  10. Treatment of Displaced Intra-articular Calcaneal Fractures by Intramedullary Nail. Preliminary Report.

    PubMed

    Falis, Mirosław; Pyszel, Krystian

    2016-03-23

    Open reduction and plate stabilisation is a recognised method of treatment of intra-articular calcaneal fractures. The surgical approach to the calcaneal bone used in these procedures is associated with a high risk of complications. The aim of this paper is to present the author's experience with a new surgical method and analyse early outcomes of the treatment of calcaneal fractures by Calcanail intramedullary nailing. The study encompassed 17 patients (5 women and 12 men) with 18 calcaneal fractures (5 in the right foot and 13 in the left foot). The mean age of the patients was 47 years (range: 22-68 years). The mean time between the injury and surgery was 6 days (range: 3-14 days). The mean duration of follow-up was 12 months (range: 6-18 months). The fractures were classified according to the system presented by Guy Utheza. Bone union was achieved in all patients within 12 weeks of surgery. No infectious complications were observed. The mean AOFAS score was 82/100. Mean Bohler's angle was -3 degrees pre-operatively and +29 degrees post-operatively. 1. The use of Calcanail intramedullary nailing in the treatment of displaced intra-articular fractures is a minimally invasive procedure associated with a low risk of complications. 2. The innovative posterior approach allows for the intrafocal reduction of an articular surface fracture through the prepared intramedullary canal.

  11. Titanium Mesh Shaping and Fixation for the Treatment of Comminuted Mandibular Fractures.

    PubMed

    Dai, Jiewen; Shen, Guofang; Yuan, Hao; Zhang, Wenbin; Shen, Shunyao; Shi, Jun

    2016-02-01

    Treating comminuted mandibular fractures remains a challenge. In this study, we used titanium mesh to treat comminuted mandibular fractures. Nine patients with traumatically comminuted mandibular fractures who received open reduction and internal stable fixation with titanium mesh were retrospectively reviewed. Open reduction-internal stable fixation was performed 7 to 10 days after primary debridement of the facial trauma. After the fractured mandible and the displaced fragments were reduced, the titanium mesh was reshaped according to the morphology of the mandible, and the reduced bone fragments were fixed with the reshaped titanium mesh and screws. Then, the surgical effects were evaluated during routine follow-up. Most of the displaced fragments were preserved and exhibited a favorable shaping ability in restoring the morphology of the mandible during surgery. No intraoperative complications were encountered. In addition, all patients were infection free, with no obvious resorption in the fixed fragments after surgery. The mandible also exhibited favorable morphology and offered sufficient bone mass for dental implantation or a denture prosthesis. We conclude that titanium mesh shaping and fixation can effectively treat comminuted mandibular fractures with little bone fragment loss, little soft tissue exposure, a low infection rate, and favorable mandibular morphology. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Oil Recovery Enhancement from Fractured, Low Permeability Reservoirs. [Carbonated Water

    DOE R&D Accomplishments Database

    Poston, S. W.

    1991-01-01

    The results of the investigative efforts for this jointly funded DOE-State of Texas research project achieved during the 1990-1991 year may be summarized as follows: Geological Characterization - Detailed maps of the development and hierarchical nature the fracture system exhibited by Austin Chalk outcrops were prepared. The results of these efforts were directly applied to the development of production decline type curves applicable to a dual-fracture-matrix flow system. Analysis of production records obtained from Austin Chalk operators illustrated the utility of these type curves to determine relative fracture/matrix contributions and extent. Well-log response in Austin Chalk wells has been shown to be a reliable indicator of organic maturity. Shear-wave splitting concepts were used to estimate fracture orientations from Vertical Seismic Profile, VSP data. Several programs were written to facilitate analysis of the data. The results of these efforts indicated fractures could be detected with VSP seismic methods. Development of the EOR Imbibition Process - Laboratory displacement as well as Magnetic Resonance Imaging, MRI and Computed Tomography, CT imaging studies have shown the carbonated water-imbibition displacement process significantly accelerates and increases recovery from oil saturated, low permeability rocks. Field Tests - Two operators amenable to conducting a carbonated water flood test on an Austin Chalk well have been identified. Feasibility studies are presently underway.

  13. A comprehensive study on the damage tolerance of ultrafine-grained copper

    PubMed Central

    Hohenwarter, A.; Pippan, R.

    2012-01-01

    In this study the fracture behavior of ultrafine-grained copper was assessed by means of elasto-plastic fracture mechanics. For the synthesis of the material high pressure torsion was used. The fracture toughness was quantitatively measured by JIC as a global measure by recording the crack growth resistance curve. Additionally, the initiation toughness in terms of the crack opening displacement (CODi) was evaluated as a local fracture parameter. The results presented here exhibit a low fracture initiation toughness but simultaneously a remarkably high fracture toughness in terms of JIC. The origin of the large difference between these two parameters, peculiarities of the fracture surface and the fracture mechanical performance compared to coarse grained copper will be discussed. PMID:23471016

  14. Surface displacements and energy release rates for constant stress drop slip zones in joined elastic quarter spaces

    NASA Astrophysics Data System (ADS)

    Rodgers, Michael J.; Wen, Shengmin; Keer, Leon M.

    2000-08-01

    A three-dimensional quasi-static model of faulting in an elastic half-space with a horizontal change of material properties (i.e., joined elastic quarter spaces) is considered. A boundary element method is used with a stress drop slip zone approach so that the fault surface relative displacements as well as the free surface displacements are approximated in elements over their respective domains. Stress intensity factors and free surface displacements are calculated for a variety of cases to show the phenomenological behavior of faulting in such a medium. These calculations showed that the behavior could be distinguished from a uniform half-space. Slip in a stiffer material increases, while slip in a softer material decreases the energy release rate and the free surface displacements. Also, the 1989 Kalapana earthquake was located on the basis of a series of forward searches using this method and leveling data. The located depth is 8 km, which is the closer to the seismically inferred depth than that determined from other models. Finally, the energy release rate, which can be used as a fracture criterion for fracture at this depth, is calculated to be 11.1×106 J m-2.

  15. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    PubMed

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  16. Clinical comparison between open plating and minimally invasive plate osteosynthesis for displaced proximal humeral fractures: A prospective randomized controlled trial.

    PubMed

    Sohn, Hoon-Sang; Jeon, Yoon Sang; Lee, JuHan; Shin, Sang-Jin

    2017-06-01

    Recently, minimally invasive plate osteosynthesis (MIPO) has been widely used for the treatment of proximal humeral fractures. However, there is concern about whether the MIPO in comminuted proximal humeral fractures is also comparable to open plating. The purpose of this study was to compare the clinical and radiographic outcomes of open plating and MIPO for acute displaced proximal humeral fractures. In this prospective, randomized controlled study, 107 patients who had an acute proximal humeral fracture were randomized to either the open plating or MIPO techniques. Forty-five patients treated with open plating and 45 with the MIPO technique who were followed up at least 1year were evaluated. Shoulder functional assessment, operating time, several radiographic parameters, and complications were evaluated at final follow-up. The mean follow-up period was 15.0 months in the open plating and 14.3 months in the MIPO technique. There were no statistically significant differences in functional assessment scores and radiographic parameters between the two groups. High complications rates were found in 4-part fracture in both surgical methods The average operation time in the MIPO group were significantly lower compared to the open plating group (p<0.05). This study showed MIPO in proximal humerus fractures had similar clinical and radiographic outcomes compared to the open plating. However, the MIPO technique in proximal humerus fracture provided significantly shorter operation time than the open plating. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. On the mechanical interaction between a fluid-filled fracture and the earth's surface

    USGS Publications Warehouse

    Pollard, D.D.; Holzhausen, G.

    1979-01-01

    The mechanical interaction between a fluid-filled fracture (e.g., hydraulic fracture joint, or igneous dike) and the earth's surface is analyzed using a two-dimensional elastic solution for a slit of arbitrary inclination buried beneath a horizontal free surface and subjected to an arbitrary pressure distribution. The solution is obtained by iteratively superimposing two fundamental sets of analytical solutions. For uniform internal pressure the slit behaves essentially as if it were in an infinite region if the depth-to-center is three times greater than the half-length. For shallower slits interaction with the free surface is pronounced: stresses and displacements near the slit differ by more than 10% from values for the deeply buried slit. The following changes are noted as the depth-to-center decreases: 1. (1) the mode I stress intensity factor increases for both ends of the slit, but more rapidly at the upper end; 2. (2) the mode II stress-intensity factor is significantly different from zero (except for vertical slits) suggesting propagation out of the original plane of the slit; 3. (3) displacements of the slit wall are asymmetric such that the slit gaps open more widely near the upper end. Similar changes are noted if fluid density creates a linear pressure gradient that is smaller than the lithostatic gradient. Under such conditions natural fractures should propagate preferentially upward toward the earth's surface requiring less pressure as they grow in length. If deformation near the surface is of interest, the model should account explicitly for the free surface. Stresses and displacements at the free surface are not approximated very well by values calculated along a line in an infinite region, even when the slit is far from the line. As depth-to-center of a shallow pressurized slit decreases, the following changes are noted: 1. (1) displacements of the free surface increase to the same order of magnitude as the displacements of the slit walls, 2. (2) tensile stresses of magnitude greater than the pressure in the slit are concentrated along the free surface. The relative surface displacements over a shallow vertical slit are downward over the slit and upward to both sides of this area. The tensile stress acting parallel to the free surface over a shallow vertical slit is concentrated in two maxima adjacent to a point of very low stress immediately over the slit. The solution is used to estimate the length-to-depth ratio at which igneous sills have gained sufficient leverage on overlying strata to bend these strata upward and form a laccolith. The pronounced mode II stress intensity associated with shallow horizontal slits explains the tendency for some sills to climb to higher stratigraphie horizons as they grow in length. The bimodal tensile stress concentration over shallow vertical slits correlates qualitatively with the distribution of cracks and normal faults which flank fissure eruptions on volcanoes. The solution may be used to analyze surface displacements and tilts over massive hydraulic fractures in oil fields and to understand the behavior of hydraulic fractures in granite quarries. ?? 1979.

  18. Evaluation of stability of osteosynthesis with K-wires on an artificial model of tibial malleolus fracture.

    PubMed

    Bumči, Igor; Vlahović, Tomislav; Jurić, Filip; Žganjer, Mirko; Miličić, Gordana; Wolf, Hinko; Antabak, Anko

    2015-11-01

    Paediatric ankle fractures comprise approximately 4% of all paediatric fractures and 30% of all epiphyseal fractures. Integrity of the ankle "mortise", which consists of tibial and fibular malleoli, is significant for stability and function of the ankle joint. Tibial malleolar fractures are classified as SH III or SH IV intra-articular fractures and, in cases where the fragments are displaced, anatomic reposition and fixation is mandatory. Type SH III-IV fractures of the tibial malleolus are usually treated with open reduction and fixation with cannulated screws that are parallel to the physis. Two K-wires are used for temporary stabilisation of fragments during reduction. A third "guide wire" for the screw is then placed parallel with the physis. Considering the rules of mechanics, it is assumed that the two temporary pins with the additional third pin placed parallel to the physis create a strong triangle and thus provide strong fracture fixation. To prove this hypothesis, an experiment was conducted on the artificial models of the lower end of the tibia from the company "Sawbones". Each model had been sawn in a way that imitates the fracture of medial malleoli and then reattached with 1.8mm pins in various combinations. Prepared models were then tested for tensile and pressure forces. The least stable model was that in which the fractured pieces were attached with only two parallel pins. The most stable model comprised three pins, where two crossed pins were inserted in the opposite compact bone and the third pin was inserted through the epiphysis parallel with and below the growth plate. A potential method of choice for fixation of tibial malleolar fractures comprises three K-wires, where two crossed pins are placed in the opposite compact bone and one is parallel with the growth plate. The benefits associated with this method include shorter operating times and avoidance of a second operation for screw removal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial

    PubMed Central

    Achten, Juul; Parsons, Nick R; Rangan, Amar; Griffin, Damian; Tubeuf, Sandy; Lamb, Sarah E

    2014-01-01

    Objectives To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. Design A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. Setting 18 trauma centres in the United Kingdom. Participants 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. Interventions Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. Main outcome measures Primary outcome measure: validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient’s experience of pain and disability to give a score out of 100. Secondary outcomes: disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. Results The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was −1.3, 95% confidence interval −4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. Conclusions Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. Trial registration Current Controlled Trials ISCRTN 31379280. UKCRN 8956. PMID:25096595

  20. Efficacy of plain radiography and computer tomography in localizing the site of pelvic arterial bleeding in trauma patients.

    PubMed

    Dormagen, Johann B; Tötterman, Anna; Røise, Olav; Sandvik, Leiv; Kløw, Nils-E

    2010-02-01

    Immediate angiography is warranted in pelvic trauma patients with suspected arterial injury (AI) in order to stop ongoing bleeding. Prior to angiography, plain pelvic radiography (PPR) and abdominopelvic computer tomography (CT) are performed to identify fracture and hematoma sites. To investigate if PPR and CT can identify the location of AI in trauma patients undergoing angiography. 95 patients with pelvic fractures on PPR (29 women, 66 men), at a mean age of 44 (9-92) years, underwent pelvic angiography for suspected AI. Fifty-six of them underwent CT additionally. Right and left anterior and posterior fractures on PPR were registered, and fracture displacement was recorded for each quadrant. Arterial blush on CT was registered, and the size of the hematoma in each region was measured in cm(2). AIs were registered for anterior and posterior segments of both internal iliac arteries. Presence of fractures, arterial blush, and hematomas were correlated with AI. Presence of fracture in the corresponding skeletal segment on PPR showed sensitivity and specificity of 0.86 and 0.58 posteriorly, and 0.87 and 0.44 anteriorly. The area under the curve (AUC) was 0.77 and 0.69, respectively. Fracture displacement on PPR >0.9 cm posteriorly and >1.9 cm anteriorly revealed specificity of 0.84. Sensitivities of arterial blush and hematoma on CT were 0.38 and 0.82 posteriorly, and 0.24 and 0.82 anteriorly. The specificities were 0.96 and 0.58 posteriorly, and 0.79 and 0.53 anteriorly, respectively. For hematomas, the AUC was 0.79 posteriorly and 0.75 anteriorly. Size of hematoma >22 cm(2) posteriorly and >29 cm(2) anteriorly revealed specificity of 0.85 and 0.86, respectively. CT findings of arterial blush and hematoma predicted site of arterial bleeding on pelvic angiography. Also, PPR predicted the site of bleeding using location of fracture and size of displacement. In the hemodynamically unstable patient, PPR may contribute equally to effective assessment of injured arteries.

  1. Analysis of patterns and treatment strategies for mandibular condyle fractures: review of 175 condyle fractures with review of literature.

    PubMed

    Reddy, N Viveka V; Reddy, P Bhaskar; Rajan, Ritesh; Ganti, Srinivas; Jhawar, D K; Potturi, Abhinand; Pradeep

    2013-09-01

    This study aims to evaluate incidence, patterns and epidemiology of mandibular condylar fractures (MCF) to propose a treatment strategy for managing MCF and analyze the factors which influence the outcome. One hundred and seventy-five MCF's were evaluated over a four year period and their pattern was recorded in terms of displacement, level of fracture, age of incidence and dental occlusion. Of the 2,718 facial bone fractures, MCF incidence was the third most common at 18.39 %. Of 175 MCF 58.8 % were unilateral and 41.12 % were bilateral. 67 % of bilateral fractures and 43.8 % of unilateral fractures were associated with midline symphysis and contralateral parasymphysis fractures respectively. Most of the MCF was seen in the age group of above 16 years and 50 % of them were at subcondylar level (below the neck of the condyle). Majority of MCF sustained due to inter personal violence were undisplaced (72.7 %) and contrary to this majority of MCF sustained during road traffic accident were displaced. 62.9 % of total fractures required open reduction and rigid fixation and 37.1 % were managed with closed reduction. 80 % of MCF managed with closed reduction were in the age group of below 16 years. From this study it can be concluded that the treatment algorithm proposed for managing MCF is reliable and easy to adopt. We observed that absolute indication for open reduction of MCF is inability to achieve satisfactory occlusion by closed method and absolute contraindication for open reduction is condylar head fracture irrespective of the age of the patient.

  2. Partial proximal tibia fractures

    PubMed Central

    Raschke, Michael J.; Kittl, Christoph; Domnick, Christoph

    2017-01-01

    Partial tibial plateau fractures may occur as a consequence of either valgus or varus trauma combined with a rotational and axial compression component. High-energy trauma may result in a more complex and multi-fragmented fracture pattern, which occurs predominantly in young people. Conversely, a low-energy mechanism may lead to a pure depression fracture in the older population with weaker bone density. Pre-operative classification of these fractures, by Müller AO, Schatzker or novel CT-based methods, helps to understand the fracture pattern and choose the surgical approach and treatment strategy in accordance with estimated bone mineral density and the individual history of each patient. Non-operative treatment may be considered for non-displaced intra-articular fractures of the lateral tibial condyle. Intra-articular joint displacement ⩾ 2 mm, open fractures or fractures of the medial condyle should be reduced and fixed operatively. Autologous, allogenic and synthetic bone substitutes can be used to fill bone defects. A variety of minimally invasive approaches, temporary osteotomies and novel techniques (e.g. arthroscopically assisted reduction or ‘jail-type’ screw osteosynthesis) offer a range of choices for the individual and are potentially less invasive treatments. Rehabilitation protocols should be carefully planned according to the degree of stability achieved by internal fixation, bone mineral density and other patient-specific factors (age, compliance, mobility). To avoid stiffness, early functional mobilisation plays a major role in rehabilitation. In the elderly, low-energy trauma and impression fractures are indicators for the further screening and treatment of osteoporosis. Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160067. Originally published online at www.efortopenreviews.org PMID:28630761

  3. Assessment of a novel biomechanical fracture model for distal radius fractures

    PubMed Central

    2012-01-01

    Background Distal radius fractures (DRF) are one of the most common fractures and often need surgical treatment, which has been validated through biomechanical tests. Currently a number of different fracture models are used, none of which resemble the in vivo fracture location. The aim of the study was to develop a new standardized fracture model for DRF (AO-23.A3) and compare its biomechanical behavior to the current gold standard. Methods Variable angle locking volar plates (ADAPTIVE, Medartis) were mounted on 10 pairs of fresh-frozen radii. The osteotomy location was alternated within each pair (New: 10 mm wedge 8 mm / 12 mm proximal to the dorsal / volar apex of the articular surface; Gold standard: 10 mm wedge 20 mm proximal to the articular surface). Each specimen was tested in cyclic axial compression (increasing load by 100 N per cycle) until failure or −3 mm displacement. Parameters assessed were stiffness, displacement and dissipated work calculated for each cycle and ultimate load. Significance was tested using a linear mixed model and Wald test as well as t-tests. Results 7 female and 3 male pairs of radii aged 74 ± 9 years were tested. In most cases (7/10), the two groups showed similar mechanical behavior at low loads with increasing differences at increasing loads. Overall the novel fracture model showed a significant different biomechanical behavior than the gold standard model (p < 0,001). The average final loads resisted were significantly lower in the novel model (860 N ± 232 N vs. 1250 N ± 341 N; p = 0.001). Conclusion The novel biomechanical fracture model for DRF more closely mimics the in vivo fracture site and shows a significantly different biomechanical behavior with increasing loads when compared to the current gold standard. PMID:23244634

  4. Beyond-laboratory-scale prediction for channeling flows through subsurface rock fractures with heterogeneous aperture distributions revealed by laboratory evaluation

    NASA Astrophysics Data System (ADS)

    Ishibashi, Takuya; Watanabe, Noriaki; Hirano, Nobuo; Okamoto, Atsushi; Tsuchiya, Noriyoshi

    2015-01-01

    The present study evaluates aperture distributions and fluid flow characteristics for variously sized laboratory-scale granite fractures under confining stress. As a significant result of the laboratory investigation, the contact area in fracture plane was found to be virtually independent of scale. By combining this characteristic with the self-affine fractal nature of fracture surfaces, a novel method for predicting fracture aperture distributions beyond laboratory scale is developed. Validity of this method is revealed through reproduction of the results of laboratory investigation and the maximum aperture-fracture length relations, which are reported in the literature, for natural fractures. The present study finally predicts conceivable scale dependencies of fluid flows through joints (fractures without shear displacement) and faults (fractures with shear displacement). Both joint and fault aperture distributions are characterized by a scale-independent contact area, a scale-dependent geometric mean, and a scale-independent geometric standard deviation of aperture. The contact areas for joints and faults are approximately 60% and 40%. Changes in the geometric means of joint and fault apertures (µm), em, joint and em, fault, with fracture length (m), l, are approximated by em, joint = 1 × 102 l0.1 and em, fault = 1 × 103 l0.7, whereas the geometric standard deviations of both joint and fault apertures are approximately 3. Fluid flows through both joints and faults are characterized by formations of preferential flow paths (i.e., channeling flows) with scale-independent flow areas of approximately 10%, whereas the joint and fault permeabilities (m2), kjoint and kfault, are scale dependent and are approximated as kjoint = 1 × 10-12 l0.2 and kfault = 1 × 10-8 l1.1.

  5. Stress fluctuations in fracture networks from theoretical and numerical models

    NASA Astrophysics Data System (ADS)

    Davy, P.; Darcel, C.; Mas Ivars, D.; Le Goc, R.

    2017-12-01

    We analyze the spatial fluctuations of stress in a simple tridimensional model constituted by a population of disc-shaped fractures embedded in an elastic matrix with uniform and isotropic properties. The fluctuations arise from the classical stress enhancement at fracture tips and stress shadowing around fracture centers that are amplified or decreased by the interactions between close-by fractures. The distribution of local stresses is calculated at the elementary mesh scale with the 3DEC numerical program based on the distinct element method. As expected, the stress distributions vary with fracture density, the larger is the density, the wider is the distribution. For freely slipping fractures, it is mainly controlled by the percolation parameter p (i.e., the total volume of spheres surrounding fractures). For stresses smaller than the remote deviatoric stress, the distribution depends only on for the range of density that has been studied. For large stresses, the distribution decreases exponentially when increasing stress, with a characteristic stress that increases with entailing a widening of the stress distribution. We extend the analysis to fractures with plane resistance defined by an elastic shear stiffness ks and a slip Coulomb threshold. A consequence of the fracture plane resistance is to lower the stress perturbation in the surrounding matrix by a factor that depends on the ratio between ks and a fracture-matrix stiffness km mainly dependent on the ratio between Young modulus and fracture size. km is also the ratio between the remote shear stress and the displacement across the fracture plane in the case of freely slipping fractures. A complete analytical derivation of the expressions of the stress perturbations and of the fracture displacements is obtained and checked with numerical simulations. In the limit ks >> km, the stress perturbation tends to 0 and the stress state is spatially uniform. The analysis allows us to quantify the intensity of the stress fluctuations in fractured rocks as a function of both the fracture network characteristics (density and size distribution), and the mechanical properties (fracture shear stiffness vs matrix elastic properties).

  6. Elevated temperature crack growth

    NASA Technical Reports Server (NTRS)

    Malik, S. N.; Vanstone, R. H.; Kim, K. S.; Laflen, J. H.

    1987-01-01

    The objective of the Elevated Temperature Crack Growth Program is to evaluate proposed nonlinear fracture mechanics methods for application to hot section components of aircraft gas turbine engines. Progress during the past year included linear-elastic fracture mechanics data reduction on nonlinear crack growth rate data on Alloy 718. The bulk of the analytical work centered on thermal gradient problems and proposed fracture mechanics parameters. Good correlation of thermal gradient experimental displacement data and finite element prediction was obtained.

  7. Surgical correction of severe strabismus and enophthalmos secondary to zygomatic arch fracture in a dog.

    PubMed

    Konrade, Kricket A; Clode, Alison B; Michau, Tammy M; Roe, Simon C; Trumpatori, Brian J; Krug, William V; Gilger, Brian C

    2009-01-01

    A grossly displaced segmental zygomatic arch fracture with marked ventro-lateral deviation of the left globe was diagnosed in a 3-month-old male German Shepherd dog following a bite injury. The fracture was approached via a modified lateral orbitotomy and a fragment of the lacrimal bone removed. The rostral portion of the fracture was stabilized with a 5-hole 2.0 dynamic compression plate bone plate. The surgical correction achieved sufficient skeletal fixation for proper anatomical reduction of the globe and excellent cosmetic and functional outcomes.

  8. Long-term patient-reported outcome after fractures of the clavicle in patients aged 10 to 18 years.

    PubMed

    Randsborg, Per-Henrik; Fuglesang, Hendrik F S; Røtterud, Jan H; Hammer, Ola-Lars; Sivertsen, Einar A

    2014-06-01

    Fractures of the clavicle are common among adolescents and have traditionally been treated nonoperatively. Recent literature has demonstrated less satisfactory results than expected after conservative management of displaced fractures in adults. The purpose of this study was to evaluate the long-term patient-reported outcome after clavicle fractures in older children and adolescents. Children aged 10 to 18 years who sustained a fracture of the clavicle between 2006 and 2008 were identified in our institution's computerized files. The radiographs were examined and the fracture patterns, degree of dislocation, and shortening were measured. Medical records were reviewed and the patient-reported outcome was assessed using the Oxford Shoulder score and the Quick version of the Disability of Arm, Shoulder, and Hand questionnaire, and specific and general satisfaction scores. A total of 185 patients (median age, 14.4 y) with 172 midshaft and 13 lateral fractures were included in the study. Sixty-five (37.8%) of the midshaft fractures were displaced, and 9 of these were operated. There was one case of nonunion and one delayed union. One hundred twenty-two (70.9%) of the patients with a midshaft fracture responded to the questionnaires on an average 4.7 years after injury. Overall results were good to excellent for the majority of nonoperatively treated patients; however, shortening of the fracture had a negative effect on the Oxford Shoulder score (P=0.02), the cosmetic satisfaction score (P=0.02), and the overall satisfaction score (P=0.01). The long-term patient-reported outcome after nonoperatively treated fractures of the clavicle in adolescents is good to excellent for the majority of the patients, and nonunion is rare. However, shortening of the fracture had a small negative effect on the outcome. Conservative management should remain the mainstay of management for fractures of the clavicle in this age group. Level IV-retrospective case series.

  9. Treatment of subtalar calcanean fractures using trans-osseous limited lateral approach.

    PubMed

    Ragab, Abdelaleem H; Mubark, Islam M; Nagi, Ahmed M; Abdelnaby, Mohamed Aly

    2014-01-01

    Calcaneal fractures are the most common fractures of the tarsal bones. The majority of these fractures are produced by axial force like a fall from a height. Controversy still exists on the best line of treatment. This study is to evaluate the results of trans-osseous limited lateral approach as a minimally invasive surgical treatment of the displaced intra-articular calcaneal fractures. The study included forty two patients (46 feet) with displaced intra-articular calcaneal fractures admitted to El-Hadra University Hospital. They were treated by trans-osseous open reduction of subtalar joint and internal fixation by k-wires consuming the trans-osseous limited lateral approach. Out of 42 patients, 36 pateints (85.7%) were males. Using calcaneal fracture scoring system, the mean score was 67.55+17.35. Satisfactory results were found in 26 patients (61.9%), while 16 patients (38.1%) had unsatisfactory results. There was significant relationship between classification of the fracture and the final results (the more the grade of the fracture, the worse the final score) (x 2 =5.914, p=0.05). The value of calcaneal angles were significantly improved after surgery including bohler angle (p=0.0001), gissane angle (p=0.0001), calcaneal pitch angle (p=0.001) and calcaneofibular space (p=0.0021). 1. Trans-osseous limited lateral approach is an effective method for management of intra articular calcaneal fractures. 2. Anatomical reduction for intra articular calcaneal fractures is essential. 3. Functional outcome of intra articular calcaneal fractures depends upon the initial damage of the articular cartilage. 4. There is a need for multi-center prospective randomized study for accurate assessment of the results of operative management of intra articular calcaneal fractures involving pre and post-operative CT for assessment of reduction and using a rational scoring system and a long period of follow up.

  10. Three-dimensional finite-element analysis of chevron-notched fracture specimens

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Newman, J. C., Jr.

    1984-01-01

    Stress-intensity factors and load-line displacements were calculated for chevron-notched bar and rod fracture specimens using a three-dimensional finite-element analysis. Both specimens were subjected to simulated wedge loading (either uniform applied displacement or uniform applied load). The chevron-notch sides and crack front were assumed to be straight. Crack-length-to-specimen width ratios (a/w) ranged from 0.4 to 0.7. The width-to-thickness ratio (w/B) was 1.45 or 2. The bar specimens had a height-to-width ratio of 0.435 or 0.5. Finite-element models were composed of singularity elements around the crack front and 8-noded isoparametric elements elsewhere. The models had about 11,000 degrees of freedom. Stress-intensity factors were calculated by using a nodal-force method for distribution along the crack front and by using a compliance method for average values. The stress intensity factors and load-line displacements are presented and compared with experimental solutions from the literature. The stress intensity factors and load-line displacements were about 2.5 and 5 percent lower than the reported experimental values, respectively.

  11. Evaluation of mandibular angle ostectomy using three-dimensional finite element analysis.

    PubMed

    Song, Jian; Zhu, Songsong; Luo, En; Hu, Jing; Feng, Ge

    2014-07-01

    This study was designed to investigate the stress and the displacement distributions of the mandible after mandibular angle ostectomy (MAO) by means of three-dimensional finite element analysis. On the basis of a female patient with a prominent angle of the mandible, the finite element models were generated by helical computed tomography and related software and were analyzed under muscle forces and 3 kinds of biting conditions, including intercuspal position (ICP), incisal clenching (INC), and right unilateral molar clenching (RMOL). The mandibular stress and displacement distributions were analyzed by Abaqus software. In the model of MAO, the increased stress and the decreased displacement was found in ICP, INC, and RMOL at the area of mandibular angle. The stress and the displacement increased in ICP and RMOL, whereas the others remained unchanged in INC at the area of mandibular condylar neck. The results of this study have shown that MAO could alter biomechanical characteristics in the operated mandible, which suggested that a greater hit on face may lead to a higher incidence rate of condyle fracture and a lower incidence rate of angle fracture after MAO.

  12. Predictors for Long-Term Hip Survivorship Following Acetabular Fracture Surgery: Importance of Gap Compared with Step Displacement.

    PubMed

    Verbeek, Diederik O; van der List, Jelle P; Tissue, Camden M; Helfet, David L

    2018-06-06

    Historically, the greatest residual (gap or step) displacement is used to predict clinical outcome following acetabular fracture surgery. Gap and step displacement may, however, impact the outcome to different degrees. We assessed the individual relationship between gap or step displacement and hip survivorship and determined their independent association with conversion to total hip arthroplasty. Patients who had acetabular fracture fixation (from 1992 through 2014), follow-up of ≥2 years (or early conversion to total hip arthroplasty), and postoperative computed tomography (CT) scans were included. Of 227 patients, 55 (24.2%) had conversion to total hip arthroplasty at a mean follow-up (and standard deviation) of 8.7 ± 5.6 years. Residual gap and step displacement were measured using a standardized CT-based method, and assessors were blinded to the outcome. Kaplan-Meier survivorship curves for the hips were plotted and compared (log-rank test) using critical cutoff values for gap and step displacement. These values were identified using receiver operating characteristic curves. Multivariate analysis was performed to identify independent variables associated with conversion to total hip arthroplasty. Subgroup analysis was performed in younger patients (<50 years old). The critical CT cutoff value for total hip arthroplasty conversion was 5 mm for gap and 1 mm for step displacement. Hip survivorship at 10 years was 82.0% for patients with a gap of <5 mm compared with 56.5% for a gap of ≥5 mm (p < 0.001) and 80.0% for a step of <1.0 mm versus 65.5% for a step of ≥1.0 mm (p = 0.012). A gap of ≥5 mm (hazard ratio [HR], 2.3; p = 0.012) and an age of ≥50 years (HR, 4.2; p < 0.001) were independently associated with conversion to total hip arthroplasty in all patients. In the subgroup of younger patients, only a step of ≥1 mm (HR, 6.4; p = 0.017) was an independent factor for conversion to total hip arthroplasty. Residual gap and step displacement as measured on CT scans are both related to long-term hip survivorship, but step displacement (1 mm) is tolerated less than gap displacement (5 mm). Of the 2 types of displacement, only a large gap displacement (≥5 mm) was independently associated with conversion to total hip arthroplasty. In younger patients who had less articular impaction with smaller residual gaps, only step displacement (≥1 mm) appeared to be associated with this outcome. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. More complications with uncemented than cemented femoral stems in total hip replacement for displaced femoral neck fractures in the elderly

    PubMed Central

    Chammout, Ghazi; Muren, Olle; Laurencikas, Evaldas; Bodén, Henrik; Kelly-Pettersson, Paula; Sjöö, Helene; Stark, André; Sköldenberg, Olof

    2017-01-01

    Background and purpose Total hip replacement (THR) is the preferred method for the active and lucid elderly patient with a displaced femoral neck fracture (FNF). Controversy still exists regarding the use of cemented or uncemented stems in these patients. We compared the effectiveness and safety between a modern cemented, and a modern uncemented hydroxyapatite-coated femoral stem in patients 65–79 years of age who were treated with THR for displaced FNF. Patients and methods In a single-center, single-blinded randomized controlled trial, we included 69 patients, mean age 75 (65–79) and with a displaced FNF (Garden III–IV). 35 patients were randomized to a cemented THR and 34 to a reverse-hybrid THR with an uncemented stem. Primary endpoints were: prevalence of all hip-related complications and health-related quality of life, evaluated with EuroQol-5D (EQ-5D) index up to 2 years after surgery. Secondary outcomes included: overall mortality, general medical complications, and hip function. The patients were followed up at 3, 12, and 24 months. Results According to the calculation of sample size, 140 patients would be required for the primary endpoints, but the study was stopped when only half of the sample size was included (n = 69). An interim analysis at that time showed that the total number of early hip-related complications was substantially higher in the uncemented group, 9 (among them, 3 dislocations and 4 periprosthetic fractures) as compared to 1 in the cemented group. The mortality and functional outcome scores were similar in the 2 groups. Interpretation We do not recommend uncemented femoral stems for the treatment of elderly patients with displaced FNFs. PMID:27967333

  14. Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis.

    PubMed

    Darwich, Mhd Ayham; Albogha, Mhd Hassan; Abdelmajeed, Adnan; Darwich, Khaldoun

    2016-04-01

    The aim of this study was to compare the performances of 5 plating techniques for fixation of unilateral mandibular subcondylar fracture. Five titanium plating techniques for fixation of condylar fracture were analyzed using the finite element method. The modeled techniques were 1) 1 straight plate, 2) 2 parallel straight plates, 3) 2 angulated straight plates, 4) 1 trapezoidal plate, and 5) 1 square plate. Three-dimensional models were generated using patient-specific geometry for the mandible obtained from a computerized tomographic image of a healthy living man. Plates were designed and combined with the mandible and analyzed under a 500-N load. The single straight plate presented the most inferior performance; it presented maximum displacement and strain on cortical bone. The trapezoidal plate induced the least amount of strain on cortical bone and was best at resisting displacement. The trapezoidal plate is recommended for fixation of subcondylar fracture. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Acute fractures of the pediatric foot and ankle.

    PubMed

    Halai, Mansur; Jamal, Bilal; Rea, Paul; Qureshi, Mobeen; Pillai, Anand

    2015-02-01

    Injuries around the foot and ankle are challenging. There is a paucity of literature, outside that of specialist orthopedic journals, that focuses on this subject in the pediatric population. In this review, we outline pediatric foot and ankle fractures in an anatomically oriented manner from the current literature. Our aim is to aid the emergency department doctor to manage these challenging injuries more effectively in the acute setting. These injuries require a detailed history and examination to aid the diagnosis. Often, plain radiographs are sufficient, but more complex injuries require the use of magnetic resonance imaging. Treatment is dependent on the proximity to skeletal maturity and the degree of displacement of fracture. Children have a marked ability to remodel after fractures and therefore mainstay treatment is immobilization by a cast or splint. Operative fixation, although uncommon in this population, may be necessary with adolescents, certain unstable injuries or in cases with displaced articular surface. In the setting of severe foot trauma, skin compromise and compartment syndrome of the foot must be excluded. The integrity of the physis, articular surface and soft tissues are all equally important in treating these injuries.

  16. Can the displacement of a conservatively treated distal radius fracture be predicted at the beginning of treatment?

    PubMed Central

    Einsiedel, T.; Freund, W.; Sander, S.; Trnavac, S.; Gebhard, F.

    2008-01-01

    The aim of this study was to investigate whether the final displacement of conservatively treated distal radius fractures can be predicted after primary reduction. We analysed the radiographic documents of 311 patients with a conservatively treated distal radius fracture at the time of injury, after reduction and after bony consolidation. We measured the dorsal angulation (DA), the radial angle (RA) and the radial shortening (RS) at each time point. The parameters were analysed separately for metaphyseally “stable” (A2, C1) and “unstable” (A3, C2, C3) fractures, according to the AO classification system. Spearman’s rank correlations and regression functions were determined for the analysis. The highest correlations were found for the DA between the time points ‘reduction’ and ‘complete healing’ (r = 0.75) and for the RA between the time points ‘reduction’ and ‘complete healing’ (r = 0.80). The DA and the RA after complete healing can be predicted from the regression functions. PMID:18504577

  17. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    PubMed

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  18. Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study.

    PubMed

    Kandemir, Utku; Herfat, Safa; Herzog, Mary; Viscogliosi, Paul; Pekmezci, Murat

    2017-02-01

    The goal of this study is to compare the fatigue strength of a locking intramedullary nail (LN) construct with a double locking plate (DLP) construct in comminuted proximal extra-articular tibia fractures. Eight pairs of fresh frozen cadaveric tibias with low bone mineral density [age: 80 ± 7 (SD) years, T-score: -2.3 ± 1.2] were used. One tibia from each pair was fixed with LN, whereas the contralateral side was fixed with DLP for complex extra-articular multifragmentary metaphyseal fractures (simulating OTA 41-A3.3). Specimens were cyclically loaded under compression simulating single-leg stance by staircase method out to 260,000 cycles. Every 2500 cycles, localized gap displacements were measured with a 3D motion tracking system, and x-ray images of the proximal tibia were acquired. To allow for mechanical settling, initial metrics were calculated at 2500 cycles. The 2 groups were compared regarding initial construct stiffness, initial medial and lateral gap displacements, stiffness at 30,000 cycles, medial and lateral gap displacements at 30,000 cycles, failure load, number of cycles to failure, and failure mode. Failure metrics were reported for initial and catastrophic failures. DLP constructs exhibited higher initial stiffness and stiffness at 30,000 cycles compared with LN constructs (P < 0.03). There were no significant differences between groups for loads at failure or cycles to failure. For the fixation of extra-articular proximal tibia fractures, a LN provides a similar fatigue performance to double locked plates. The locked nail could be safely used for fixation of proximal tibia fractures with the advantage of limited extramedullary soft tissue damage.

  19. Comparison of a technique using a new percutaneous osteosynthesis device with conventional open surgery for displaced patella fractures in a randomized controlled trial.

    PubMed

    Luna-Pizarro, Daniel; Amato, Dante; Arellano, Francisco; Hernández, Armando; López-Rojas, Pablo

    2006-09-01

    To compare the percutaneous patellar osteosynthesis system (PPOS) technique with open surgery for patella fractures. Randomized controlled trial. Referral orthopedic and trauma center. Fifty-three patients with displaced patellar fractures. Stabilization and fixation of patellar fractures with PPOS or open surgery. Knee-flexion and -extension angles, pain, surgical time, and assessment of knee function based on the Knee Society Clinical Rating Scale (KSCRS). Comparison of PPOS and open-surgery groups at 4 weeks showed the following: pain, 3.7 +/- 1.6 versus 6.2 +/- 1.4 arbitrary units, P < 0.001; flexion angle, 46 +/- 20.7 versus 12.7 +/- 6.0 degrees, P < 0.001; extension angle, -2.5 versus -3.8 degrees, P < 0.001. At 8 weeks, the following was demonstrated: pain, 1.3 +/- 1.6 versus 4.1 +/- 2.1 arbitrary units, P < 0.001; flexion angle, 87 +/- 17.3 versus 34 +/- 26 degrees, P < 0.001; extension angle, 0 versus -3 degrees, P < 0.001. Surgical time was 35.3 +/- 7.8 versus 66.2 +/- 14.1 minutes, P < 0.001. KSCRS assessment was 84 +/- 4 versus 70 +/- 8, P < 0.001 at 8 weeks; 85 +/- 2 versus 73 +/- 8, P < 0.001 at 12 months; and 85 +/- 1 versus 82 +/- 7, P = 0.246 at 24 months. Frequency of total complications (infections, fragment displacement, and wire-related pain) was significantly lower in the PPOS than in the open-surgery group (P < 0.02). PPOS for patella fractures was associated with shorter surgical time, less pain, better mobility angles, higher functional score up to 2 years, and a lower incidence of complications than open surgery.

  20. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    PubMed Central

    2011-01-01

    Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires) and volar plate fixation using fixed-angle screws (locking-plates). The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956 PMID:21914196

  1. Microstructural analysis of calcite-filled fractures inherited from basement structures, southern Ontario, Canada: long term instability of the craton?

    NASA Astrophysics Data System (ADS)

    Spalding, Jennifer; Schneider, David

    2016-04-01

    Intra-cratonic regions are generally characterized by tectonic stability and low seismicity. In southern Ontario, Canada, moderate levels of seismicity have been recorded over the last few decades reaching magnitudes of 5 MN, indicating that the geosphere is not as stable as predicted. The stratigraphy of the region consists of Ordovician limestone with a thickness of ~200 m that unconformably overlays the Mesoproterozoic crystalline Grenville Province. Subsequent tectonism including repeated Paleozoic orogenies and rifting along the east coast of North America has reactivated Proterozoic structures that have propagated into the overlying carbonate platform forming mesoscopic-scale brittle structures. Exposed along the shores of Lake Ontario are decameter-scale fracture zones, with a fracture spacing of 0.5 to 10 meters. The dominant fracture set trends E-W, and often forms conjugate sets with less prominent NNE-oriented fractures. More locally, an older NW-oriented fracture set is cross cut by the E-W and NNE oriented fractures. Regionally, there have been six directions of maximum horizontal stress in southern Ontario since the Precambrian, with the current orientation of maximum stress oriented ENE as a consequence of far field Atlantic ridge-push forces generated at distant plate boundaries. Calcite mineralization along fractured surfaces locally form sub-horizontal slickenside fabrics which are covered by a layer of euhedral calcite crystals, suggesting that fracture dilation (and fluid flow) occurred after fracture slip to allow the growth of calcite crystals. Due to the proximity of the carbonate units to the crystalline basement, we expect the calcitic veins to be enriched in rare earth elements and are presently conducting geochemical analyses. The calcite veins and surfaces vary from 2.5 cm to 1 mm thicknesses, often with larger calcite crystals in the center of the vein and smaller crystals at the vein boundaries, likely representing nucleation on small grains of the wall rock. Some veins show minor displacement, including the mm-scale with fractured and displaced fossil fragments, and cm-scale offsets at the outcrop. The calcite veins show evidence of low temperature deformation (~200°C) through undulous extinction, bulging grain boundaries, tension gashes structures, and extensive lamellar twinning. The width and density of twinning (twin planes/mm) provides information regarding the temperature of deformation. The calcite crystals show two populations of twinning: type I (>10 μm), and type II (tabular twinning) with an average thickness of 35 μm, and a maximum thickness of 81 μm. Twinning can only accommodate a limited amount of strain such that the calcite lamellar twinning is often kinked, broken and offset, suggesting reactivation of the calcite-filled fractures. U-Pb calcite ages from calcitic veins in the Ordovician units within the Ottawa graben are c. 400 Ma and within Devonian units at the edge of the Michigan Basin in Canada are c. 110 Ma. Additional geochronology on the calcite from southern Ontario will help resolve the timing of fracture reactivation and is an important factor in consideration of the location of a deep geological repository for Canada's nuclear waste.

  2. Spatial instability of the rift in the St. Paul multifault transform fracture system, Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    Sokolov, S. Yu.; Zaraiskaya, Yu. A.; Mazarovich, A. O.; Efimov, V. N.; Sokolov, N. S.

    2016-05-01

    The structure of the acoustic basement of the eastern part of the St. Paul multifault transform fracture system hosts rift paleovalleys and a paleonodal depression that mismatch the position of the currently active zones. This displacement zone, which is composed of five fault troughs, is unstable in terms of the position of the rift segments, which jumped according to redistribution of stresses. The St. Paul system is characterized by straightening of the transform transition between two remote segments of the Mid-Atlantic Ridge (MAR). The eastern part of the system contains anomalous bright-spot-like reflectors on the flattened basement, which is a result of atypical magmatism, that forms the standard ridge relief of the acoustic basement. Deformations of the acoustic basement have a presedimentation character. The present-day deformations with lower amplitude in comparison to the basement are accompanied by acoustic brightening of the sedimentary sequence. The axial Bouguer anomalies in the east of the system continue to the north for 120 km from the active segments of the St. Paul system. Currently seismically active segments of the spreading system are characterized by increasing amplitudes of the E-W displacement along the fault troughs. Cross-correlation of the lengths of the active structural elements of the MAR zone (segments of the ridge and transform fracture zones of displacement) indicates that, statistically, the multifault transform fracture system is a specific type of oceanic strike-slip faults.

  3. Outcome Determining Factors for displaced Intra-articular Calcaneal Fractures treated operatively

    PubMed Central

    Chan, KL; Idham, HM; Izani, IM; Nahulan, T

    2015-01-01

    Introduction: Calcaneal fractures are caused by high energy trauma and mostly are intra-articular fractures. Nondisplaced intra-articular calcaneal fracture (IACF) can be treated non-operatively. However, displaced intra-articular need to be reduced and fixed anatomically to facilitate early ankle rehabilitation and minimize functional impairment. This study was done to find out the outcome of the IACF patients who underwent operative treatment. Methods: 62 patients with IACF were selected in this study and had been followed up from June 2009 to May 2013. They were placed into two groups; the operative treated and non-operative treated groups. Bilateral ankle lateral view plain radiographs were taken for comparison of the Bohler and Gissane angles. Both groups of patients were assessed by the Maryland Foot Score (MFS) and the SF-36v2 general health survey questionnaire. The ability of the patients to perform activity of daily living (ADL) and /or return to work (RTW) was assessed as well. Results: The operative treatment group of displaced IACF patients achieved no significant better scores in the mean MFS and SF-36v2 mean scores as compared to non operated cases. There was no difference in RTW between the 2 groups, but earlier ADL was recorded in the operated group. However, this study had found 5 associated factors which causes major effect to the patients’ outcome to treatment. Conclusions: The patient’s compliance with post-operative rehabilitation regimen were found to be significantly related with the outcomes. PMID:28611903

  4. Management of comminuted patellar fracture with non-absorbable suture cerclage and Nitinol patellar concentrator.

    PubMed

    Lue, Tan Hong; Feng, Liu Wei; Jun, Wang Ming; Yin, Li Wu

    2014-12-01

    To evaluate the effectiveness and safety of a fixation technique for comminuted patellar fracture using non-absorbable suture cerclage and nickel-titanium patellar concentrator (Ni-Ti PC). Twenty-nine consecutive patients with displaced comminuted patellar fractures accepted internal fixation procedure using Ni-Ti PC augmented with different types of non-absorbable suture cerclage. During follow-up, the clinical grading scales of Böstman, including range of movement, pain, work, atrophy, assistance in walking, effusion, giving way, and stair-climbing, were used to evaluate the clinical results. Complications including implant loosening, fragment displacement, bone nonunion, infection, breakage of the implants, painful hardware, and post-traumatic osteoarthritis were also assessed. Patients were followed up for a mean period of 27 months. The bone union radiographically occurred approximately 2.5 months without implant loosening and fragment displacement. According to Böstman method, satisfactory results were obtained, and the mean score at final follow-up was 28 (range 20–30) points. Twenty-two patients with excellent results had mean score of 29.8 ± 0.5 (range 28–30) and seven patients with good results had mean score of 22.7 ± 3.14 (range 20–27). No postoperative complications, such as infection, dislocation, breakage of the implants, painful hardware, and post-traumatic osteoarthritis, were observed. Ni-Ti PC fixation with non-absorbable suture cerclage is a feasible approach for comminuted patellar fractures. Firm fixation with this technique resulted in satisfactory outcomes without obvious complications.

  5. Hook plate fixation of acute displaced lateral clavicle fractures: mid-term results and a brief literature overview

    PubMed Central

    2012-01-01

    Background The clavicle hook plate achieves like most other operative techniques, a high percentage of union and a low percentage of complications however concerns about long term complications still exist, particularly the involvement of the acromioclavicular joint. Methods To evaluate the results and long term effects in use of this plate we performed a retrospective analysis with a mean follow up of 65 months (5.4 years) of 28 consecutive patients with acute displaced lateral clavicle fractures, treated with the clavicle hook plate. Results Short term functional results in all patients were good to excellent. All but one patient had a united fracture (96%). Nine patients (32%) developed impingement symptoms and in 7 patients (25%) subacromial osteolysis was found. These findings resolved after plate removal. Twenty-four patients were re-evaluated at a mean follow-up period of 5.4 years. The Constant-Murley score was 97 and the DASH score was 3.5. Four patients (14%) developed acromioclavicular joint arthrosis of which one was symptomatic. Three patients (11%) had extra articular ossifications of which one was symptomatic. There was no relation between the impingement symptoms, subacromial osteolysis and development of acromioclavicular joint arthrosis or extra articular ossifications. Conclusions The clavicle hook plate is a good primary treatment option for the acute displaced lateral clavicle fracture with few complications. At mid term the results are excellent and no long term complications can be addressed to the use of the plate. PMID:22236647

  6. Flow of viscoplastic suspensions in a hydraulic fracture: implications to overflush

    NASA Astrophysics Data System (ADS)

    Boronin, S. A.; Osiptsov, A. A.; Desroches, J.

    2017-10-01

    The study is devoted to modeling of multiphase flows of immiscible viscoplastic fluids in a hydraulic fracture. In the framework of the lubrication approximation, three-dimensional Navier-Stokes equations are reduced to hyperbolic transport equations for the fluid tracers and a quasi-linear elliptic equation in terms of the fluid pressure. The governing equations are solved numerically using the finite-difference approach. A parametric study of the displacement of Bingham fluids in a Hele-Shaw cell is carried out. It is found that fingers developed through the pillar of a yield-stress suspension trigger the development of unyielded zones. An increase in the Bingham number leads to an increase in the so-called finger shielding effect, which manifests itself via an increase in the overall finger penetration zone and a decrease in the total number of fingers. The effect of flow parameters on the displacement of hydraulic fracturing proppant-laden suspension by a clean fluid in the vicinity of the perforation zone is carried out. This particular case is considered in application to overflush at the end of a stimulation treatment, when a small portion of a thin clean fluid is injected to wash out the particles from the wellbore into the fracture. It is found that an increase in the yield stress and the viscosity contrast between the fracturing and the overflush fluids typically reduces the area of the cavity thus mitigating the risk of loosing the conductive path between the wellbore and the fracture after the fracture closure.

  7. Traumatic fracture of a polymethyl methacrylate patient-specific cranioplasty implant.

    PubMed

    Ko, Andrew L; Nerva, John D; Chang, Jason J J; Chesnut, Randall M

    2014-01-01

    To present a case of a traumatic fracture of a polymethyl methacrylate (PMMA) patient-specific implant (PSI) for cranioplasty. A 14-year-old boy with a history of right decompressive hemicraniectomy and reconstructive cranioplasty with a PMMA PSI presented after an unhelmeted bicycle accident with somnolence, confusion, seizures, left hemiparesis, and an obviously deformed cranium. Computed tomography scan showed a comminuted, depressed fracture of the implant and cerebral contusions. The implant was seen to be shattered, resulting in displaced, overriding fragments and significant damage to underlying brain. The patient remained neurologically stable. To minimize the number of operations, intervention was delayed while a polyetheretherketone PSI was fabricated. During surgery, it was noted that the fractured pieces of the implant had caused dural lacerations, and some pieces were embedded in brain parenchyma. The fractured PMMA was removed, and the new implant was placed. The patient remained hemiparetic and was later transferred to an inpatient rehabilitation facility. PMMA PSIs are commonly used for large defects and generally have good outcomes with low rates of revision. The case report described involves a shattered PMMA PSI after a traumatic impact, which resulted in hemiparesis. The question arises if this type of complication can be easily avoided with the addition of titanium onlay to restrict displacement in the event of fracture. This onlay represents a minor change of technique that could prevent migration of fracture fragments. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. High resolution reconstructions of Southwest Indian Ridge plate motions during the Neogene: Comparison to GPS estimates and implications for global plate motion estimates

    NASA Astrophysics Data System (ADS)

    DeMets, C.; Merkouriev, S.; Sauter, D.; Calais, E.

    2013-12-01

    Plate kinematic data from the slow-spreading Southwest Indian Ridge (SWIR) are the primary source of information about relative movements between Antarctica and Africa over geologic time and are critical for linking the movements of plates in the Atlantic and Indian Ocean basins. We describe the first high-resolution model of SWIR plate kinematics from the present to 20 Ma, consisting of rotations based on 21 magnetic reversals with ~1 million-year spacing. The new rotations, which are derived from 4822 identifications of magnetic reversals C1n to C6no and 6000 crossings of 21 fracture zones and transform faults, describe in detail the ultra-slow motions of the Nubia, Lwandle, and Somalia plates north of the SWIR relative to the Antarctic plate. A search for the Nubia-Lwandle-Antarctic triple junction with all data since C5n.2 (11.0 Ma) gives a best location at the Andrew Bain transform fault (~32E), in accord with previous work. Plate kinematic data from the SWIR east of the Andrew Bain fracture zone support the existence of the previously proposed Lwandle plate at high confidence level. The likely diffuse Lwandle-Somalia plate boundary north of the SWIR is however only loosely constrained to 45E-52E. After calibrating the new rotations for the biasing effects of finite-width magnetic polarity transition zones (i.e. outward displacement), the new rotations reveal that SWIR plate motion has remained steady from the present back to 7.5 Ma, but was modestly faster (~25%) from 19.6 Ma to 7.5 Ma. GPS estimates of present SWIR plate motions based on more than 100 continuous GPS sites on the Antarctic, Nubia, and Somalia plates are remarkably consistent with SWIR velocities determined with the new geological reconstructions. The superb agreement between the two independent plate motion estimates validates both sets of estimates and our calibration for outward displacement. Implications of the new estimates, including evidence for anomalously wide outward displacement across parts of the SWIR, will be discussed

  9. [Locked volar plating for complex distal radius fractures: maintaining radial length].

    PubMed

    Jeudy, J; Pernin, J; Cronier, P; Talha, A; Massin, P

    2007-09-01

    Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the ulnar variance and radial angulation in the first six months postoperatively. The correction of the ulnar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.

  10. Double fixation of displaced patella fractures using bioabsorbable cannulated lag screws and braided polyester suture tension bands.

    PubMed

    Qi, Li; Chang, Cao; Xin, Tang; Xing, Pei Fu; Tianfu, Yang; Gang, Zhong; Jian, Li

    2011-10-01

    To evaluate the effectiveness and safety of a new double fixation technique for displaced patellar fractures using bioabsorbable cannulated lag screws and braided polyester suture tension bands. Fifteen patients (mean age of 46.2 years) with displaced transverse or comminuted patella fractures were enrolled in this prospective study. All of the patients were treated via the open reduction internal fixation (ORIF) procedure using bioabsorbable cannulated lag screws and braided polyester suture tension bands. The patients were followed post-surgery to evaluate (1) the time required for radiographic bone union, (2) the knee joint range of motion at the time of radiographic bone union, (3) the degree of pain assessed using the visual analogue scale (VAS), (4) the function of the knee using the Lysholm score and (5) the presence of any additional complications from the surgery. All of the patients were followed post-treatment for more than 1 year (range, 12-19 months; mean post-treatment follow up time, 14 months). The bone union of the fractures as seen radiographically occurred approximately 3 months from surgery in all cases without implant failure or redisplacement of the fractured site. The mean knee joint range of motion was from 0 to 134.6°, and the mean VAS score was 0.7 at the time of bone union. The mean Lysholm scores at the time of bone union and 12 months post-surgery were 86.7 and 95.7, respectively. No postoperative complications, such as infection, dislocation or breakage of the implants, were observed. Moreover, all of the patients returned to their previous activity level. This new double fixation technique using bioabsorbable cannulated lag screws and braided polyester suture tension bands resulted in satisfactory outcomes for patella fractures without any obvious complications. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Shape Memory Alloy Rock Splitters (SMARS) - A Non-Explosive Method for Fracturing Planetary Rocklike Materials and Minerals

    NASA Technical Reports Server (NTRS)

    Benafan, Othmane; Noebe, Ronald D.; Halsmer, Timothy J.

    2015-01-01

    A static rock splitter device based on high-force, high-temperature shape memory alloys (HTSMAs) was developed for space related applications requiring controlled geologic excavation in planetary bodies such as the Moon, Mars, and near-Earth asteroids. The device, hereafter referred to as the shape memory alloy rock splitter (SMARS), consisted of active (expanding) elements made of Ni50.3Ti29.7Hf20 (at.%) that generate extremely large forces in response to thermal input. The preshaping (training) of these elements was accomplished using isothermal, isobaric and cyclic training methods, which resulted in active components capable of generating stresses in excess of 1.5 GPa. The corresponding strains (or displacements) were also evaluated and were found to be 2 to 3 percent, essential to rock fracturing and/or splitting when placed in a borehole. SMARS performance was evaluated using a test bed consisting of a temperature controller, custom heaters and heater holders, and an enclosure for rock placement and breakage. The SMARS system was evaluated using various rock types including igneous rocks (e.g., basalt, quartz, granite) and sedimentary rocks (e.g., sandstone, limestone).

  12. Biomechanical Assessment of the Dorsal Spanning Bridge Plate in Distal Radius Fracture Fixation: Implications for Immediate Weight-Bearing.

    PubMed

    Huang, Jerry I; Peterson, Bret; Bellevue, Kate; Lee, Nicolas; Smith, Sean; Herfat, Safa

    2017-04-01

    The goal of this study was to compare the biomechanical stability of a 2.4-mm dorsal spanning bridge plate with a volar locking plate (VLP) in a distal radius fracture model, during simulated crutch weight-bearing. Five paired cadaveric forearms were tested. A 1-cm dorsal wedge osteotomy was created to simulate an unstable distal radius fracture with dorsal comminution. Fractures were fixed with a VLP or a dorsal bridge plate (DBP). Specimens were mounted to a crutch handle, and optical motion-tracking sensors were attached to the proximal and distal segments. Specimens were loaded in compression at 1 mm/s on a servohydraulic test frame until failure, defined as 2 mm of gap site displacement. The VLP construct was significantly more stable to axial load in a crutch weight-bearing model compared with the DBP plate (VLP: 493 N vs DBP: 332 N). Stiffness was higher in the VLP constructs, but this was not statistically significant (VLP: 51.4 N/mm vs DBP: 32.4 N/mm). With the crutch weight-bearing model, DBP failed consistently with wrist flexion and plate bending, whereas VLP failed with axial compression at the fracture site and dorsal collapse. Dorsal spanning bridge plating is effective as an internal spanning fixator in treating highly comminuted intra-articular distal radius fracture and prevents axial collapse at the radiocarpal joint. However, bridge plating may not offer advantages in early weight-bearing or transfer in polytrauma patients, with less axial stability in our crutch weight-bearing model compared with volar plating. A stiffer 3.5-mm DBP or use of a DBP construct without the central holes may be considered for distal radius fractures if the goal is early crutch weight-bearing through the injured extremity.

  13. Analysis of bone healing in flail chest injury: do we need to fix both fractures per rib?

    PubMed

    Marasco, Silvana; Liew, Susan; Edwards, Elton; Varma, Dinesh; Summerhayes, Robyn

    2014-09-01

    Surgical rib fixation (SRF) for severe rib fracture injuries is generating increasing interest in the medical literature. It is well documented that poorly healed fractured ribs can lead to chronic pain, disability, and deformity. An unanswered question in SRF for flail chest injury is whether it is sufficient to fix one fracture per rib, on successive ribs, thus converting a flail chest injury into simple fractured ribs, or whether both ends of the floating segment of the chest wall should be fixed. This study aimed to analyze SRF in flail chest injury, assessing 3-month outcomes for nonfixed fractured rib ends in the flail segment. This is a retrospective review (2005-2013) of 60 consecutive patients who underwent SRF for flail chest injury admitted to the Alfred Hospital, Melbourne, Australia. Imaging by three-dimensional computed tomography (3D CT) of the chest at admission was compared with follow-up 3D CT at 3 months after injury. The 3-month CT scans were assessed for degree of healing and presence of residual deformity at the fracture fixation site. Follow-up CT was performed in 52 of the 60 patients. At 3 months after surgery, 86.5% of the patients had at least partial healing with good alignment and adequate fracture stabilization. Hardware failure was noted in five patients (9.6%) and occurred with the absorbable prostheses only. Six patients who had preoperative overlapping or displacement showed no improvement in deformity despite fixing the lateral fractures. Callus formation and bony bridging between adjacent ribs was often noted in the rib fractures not fixed (28 of 52 patients, 54%) This retrospective review of 3D CT chest at 3 months after rib fixation indicates that a philosophy of fixing only one fracture per rib in a flail segment does not avoid deformity and displacement, particularly in posterior rib fractures. Therapeutic study, level V; epidemiologic study, level V.

  14. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    PubMed

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Full field study of strain distribution near the crack tip in the fracture of solid propellants via large strain digital image correlation and optical microscopy

    NASA Astrophysics Data System (ADS)

    Gonzalez, Javier

    A full field method for visualizing deformation around the crack tip in a fracture process with large strains is developed. A digital image correlation program (DIC) is used to incrementally compute strains and displacements between two consecutive images of a deformation process. Values of strain and displacements for consecutive deformations are added, this way solving convergence problems in the DIC algorithm when large deformations are investigated. The method developed is used to investigate the strain distribution within 1 mm of the crack tip in a particulate composite solid (propellant) using microscopic visualization of the deformation process.

  16. Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins.

    PubMed

    Christie, J; Howie, C R; Armour, P C

    1988-03-01

    One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.

  17. Stress intensity factors of composite orthotropic plates containing periodic buffer strips

    NASA Technical Reports Server (NTRS)

    Delale, F.; Erdogan, F.

    1978-01-01

    The fracture problem of laminated plates which consist of bonded orthotropic layers is studied. The fields equations for an elastic orthotropic body are transformed to give the displacement and stress expressions for each layer or strip. The unknown functions in these expressions are found by satisfying the remaining boundary and continuity conditions. A system of singular integral equations is obtained from the mixed boundary conditions. The singular behavior around the crack tip and at the bimaterial interface is studied. The stress intensity factors are computed for various material combinations and various crack geometries. The results are discussed and are compared with those for isotropic materials.

  18. Proximal third humeral shaft fractures -- a fracture entity not fully characterized by conventional AO classification.

    PubMed

    Stedtfeld, H W; Biber, R

    2014-01-01

    The retrospective study was made to evaluate the fracture patterns at the proximal humeral shaft for which the long version of a standard proximal humeral nail (PHNLV) has been used. The indication has been decided by the individual surgeons. Over a five year period 72 consecutive PHNLV cases of an acute fracture were identified and were included in the study. Mean patient age was 68.9 years. Gender ratio was m/f=22/50. 86.1% of the patients fractured their humerus by a fall, the rest by a high velocity accident. We analysed patient comorbidity, ASA score, osteoporosis, social status before accident, additional injuries affecting local soft tissues or other anatomic regions. We analysed the expansion of the fractures, dividing the humerus into five zones. Fracture morphology was categorized according to the standard AO/ASIF classification (if applicable). Comorbidities were found in 76.4% of the patients. Almost all patients (93.1%) had been living independently at home before the accident. 47.2% of patients had osteoporosis in their medical history. Five patients (6.9%) had a primary palsy of the radial nerve. Six fractures chosen for PHNLV fixation were clearly restricted to the humeral head. The remaining 66 fractures were located in the humeral shaft (AO region 12). There were 5 segmental fractures. Of the remaining 67 fractures affecting the proximal third of the humeral shaft 49.3 percent extended into the humeral head. 98 percent of these fractures displayed spiral morphology. Proximal humeral shaft fractures are amazingly similar to subtrochanteric and distal tibial shaft fractures: Spiral fracture types with different grades of comminution are absolutely dominant; a great proportion of the fractures extend into the humeral head with growing tendency of displacement if located closer to the humeral head. Diverging traction of deltoid and pectoralis muscle causes typical displacement if the fracture line runs in between their attachments substantiating the term 'intermuscular fracture'. A distinct classification system for proximal humeral shaft fractures seems meaningful and is proposed. There is clear evidence of specific characteristics which differentiate proximal third humeral shaft fractures from those of midshaft and distal third. They explain the specific problems of reduction and fixation. If disrespected they will lead to higher rates of therapeutic failure. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Fracture of ECAP-deformed iron and the role of extrinsic toughening mechanisms

    PubMed Central

    Hohenwarter, A.; Pippan, R.

    2013-01-01

    The fracture behaviour of pure iron deformed by equal-channel angular pressing via route A was examined. The fracture toughness was determined for different specimen orientations and measured in terms of the critical plane strain fracture toughness, KIC, the critical J integral, JIC, and the crack opening displacement for crack initiation, CODi. The results demonstrate that the crack plane orientation has a pronounced effect on the fracture toughness. Different crack plane orientations lead to either crack deflection or delamination, resulting in increased fracture resistance in comparison to one remarkably weak specimen orientation. The relation between the microstructure typical for the applied deformation route and the enormous differences in the fracture toughness depending on the crack plane orientation will be analyzed in this paper. PMID:23645995

  20. Experimental compliance calibration of the compact fracture toughness specimen

    NASA Technical Reports Server (NTRS)

    Fisher, D. M.; Buzzard, R. J.

    1980-01-01

    Compliances and stress intensity coefficients were determined over crack length to width ratios from 0.1 to 0.8. Displacements were measured at the load points, load line, and crack mouth. Special fixturing was devised to permit accurate measurement of load point displacement. The results are in agreement with the currently used results of boundary collocation analyses. The errors which occur in stress intensity coefficients or specimen energy input determinations made from load line displacement measurements rather than from load point measurements are emphasized.

  1. A new technique in the surgical treatment of Hangman's fractures: Neurospinal Academy (NSA) technique

    PubMed Central

    Dalbayrak, Sedat; Yaman, Onur; Yılmaz, Mesut

    2013-01-01

    Context: Treatment of Hangman's fractures is still controversial. Hangman's fractures Type II and IIA are usually treated with surgical procedures. Aim: This study aims at describing the Neurospinal Academy (NSA) technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. Settings and Design: NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Materials and Methods: Hangman II and IIA patient are treated with NSA technique. Result: Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. Conclusions: In Hangman's fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated. PMID:24744563

  2. A new technique in the surgical treatment of Hangman's fractures: Neurospinal Academy (NSA) technique.

    PubMed

    Dalbayrak, Sedat; Yaman, Onur; Yılmaz, Mesut

    2013-07-01

    Treatment of Hangman's fractures is still controversial. Hangman's fractures Type II and IIA are usually treated with surgical procedures. This study aims at describing the Neurospinal Academy (NSA) technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Hangman II and IIA patient are treated with NSA technique. Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. In Hangman's fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated.

  3. Damage, crack growth and fracture characteristics of nuclear grade graphite using the Double Torsion technique

    NASA Astrophysics Data System (ADS)

    Becker, T. H.; Marrow, T. J.; Tait, R. B.

    2011-07-01

    The crack initiation and propagation characteristics of two medium grained polygranular graphites, nuclear block graphite (NBG10) and Gilsocarbon (GCMB grade) graphite, have been studied using the Double Torsion (DT) technique. The DT technique allows stable crack propagation and easy crack tip observation of such brittle materials. The linear elastic fracture mechanics (LEFM) methodology of the DT technique was adapted for elastic-plastic fracture mechanics (EPFM) in conjunction with a methodology for directly calculating the J-integral from in-plane displacement fields (JMAN) to account for the non-linearity of graphite deformation. The full field surface displacement measurement techniques of electronic speckle pattern interferometry (ESPI) and digital image correlation (DIC) were used to observe and measure crack initiation and propagation. Significant micro-cracking in the fracture process zone (FPZ) was observed as well as crack bridging in the wake of the crack tip. The R-curve behaviour was measured to determine the critical J-integral for crack propagation in both materials. Micro-cracks tended to nucleate at pores, causing deflection of the crack path. Rising R-curve behaviour was observed, which is attributed to the formation of the FPZ, while crack bridging and distributed micro-cracks are responsible for the increase in fracture resistance. Each contributes around 50% of the irreversible energy dissipation in both graphites.

  4. Accuracy of a Computer Assisted Program for ’Classic’ Presentations of Dental Pain

    DTIC Science & Technology

    1989-04-11

    prognosis Displace/mobility of tooth, guarded prognosis Endo / perio combined problem Enamel fracture Food impaction Fractured crown, small pulp...34 presentations. Abscess/infection/cellulitis* Endo / perio combined problem Myofascial pain/muscle spasms Reversible pulpitis *For Abscess/infection...spasms Necrotizing ulcerative gingivitis Neurologic injury Osseous sequestrum Occlusal trauma Periodontal abscess Periocoronitis/erupting tooth

  5. Stress-intensity factors and crack-opening displacements for round compact specimens. [fracture toughness of metallic materials

    NASA Technical Reports Server (NTRS)

    Newman, J. C., Jr.

    1979-01-01

    A two dimensional, boundary collocation stress analysis was used to analyze various round compact specimens. The influence of the round external boundary and of pin-loaded holes on stress intensity factors and crack opening displacements was determined as a function of crack-length-to-specimen-width ratios. A wide-range equation for the stress intensity factors was developed. Equations for crack-surface displacements and load-point displacements were also developed. In addition, stress intensity factors were calculated from compliance methods to demonstrate that load-displacement records must be made at the loading points and not along the crack line for crack-length-to-specimen-width ratios less than about 0.4.

  6. A prospective study on 284 digital fractures of the hand.

    PubMed

    Pun, W K; Chow, S P; So, Y C; Luk, K D; Ip, F K; Chan, K C; Ngai, W K; Crosby, C; Ng, C

    1989-05-01

    We report a prospective study on 284 digital fractures of the hand in 235 patients. Management followed clear guidelines set out in a protocol. Important factors in the selection of the treatment method were, acceptable alignment, functional stability, and associated "significant" soft tissue injuries. "Functionally" stable fractures treated by free mobilization had satisfactory results. Unstable fractures treated by splints or Kirschner wire fixation produced unsatisfactory results. "Open fracture," "comminuted fracture," and "associated significant soft tissue injuries" were identified as unfavorable prognostic factors. The anatomic site of the fractures was not important in determining the final outcome. About 15% of the displaced fractures became functionally stable after closed reduction and their results were comparable with the undisplaced fractures. About 30% of the patients had various degrees of difficulty after they returned to work. About 14% of the patients eventually changed their jobs because of their residual disability.

  7. Fracture properties of concrete specimens made from alkali activated binders

    NASA Astrophysics Data System (ADS)

    Šimonová, Hana; Kucharczyková, Barbara; Topolář, Libor; Bílek, Vlastimil, Jr.; Keršner, Zbyněk

    2017-09-01

    The aim of this paper is to quantify crack initiation and other fracture properties - effective fracture toughness and specific fracture energy - of two types of concrete with an alkali activated binder. The beam specimens with a stress concentrator were tested in a three-point bending test after 28, 90, and 365 days of maturing. Records of fracture tests in the form of load versus deflection (P-d) diagrams were evaluated using effective crack model and work-of-fracture method and load versus mouth crack opening displacement (P-CMOD) diagrams were evaluated using the Double-K fracture model. The initiation of cracks during the fracture tests for all ages was also monitored by the acoustic emission method. The higher value of monitored mechanical fracture parameters of concrete with alkali activated blast furnace slag were achieved with substitution blast furnace slag by low calcium fly ash in comparison with substitution by cement kiln dust.

  8. Acoustic Monitoring of Gravity-Driven Controls on CaCO3 Precipitates in a Fracture

    NASA Astrophysics Data System (ADS)

    Xu, Z.; Sheets, J.; Zhang, L.; Kim, D.; Kneafsey, T. J.; Cole, D. R.; Jun, Y. S.; Pyrak-Nolte, L. J.

    2017-12-01

    Sealing fractures by mineral precipitation is an important process for improving caprock integrity in subsurface reservoirs. In this study, the ability to monitor precipitate distribution in fractures with buoyant fluids was examined. Fractures with uniform aperture distributions of 0.5, 1.0 and 2.0 mm were created from acrylic plates to enable direct imaging of precipitate formation over time. CaCO3 precipitation was induced in a fracture from invasion of 1M CaCl2 and 0.3M Na2CO3 solutions. During chemical invasion, a fracture plane was oriented either parallel or perpendicular to gravity. Acoustic (P) wave transmission ( 1 MHz) and optical imaging were used to monitor the sample prior to, during and after fluid injection. Complementary X-ray computed tomography was performed throughout the experiments on vertical fractures and post injection for the horizontal fractures. Precipitate particle sizes during formation were determined using SAXS and WAXS. In both horizontal and vertical fractures, the density contrast between the two solutions affected the spatial distribution of precipitation. In vertical fractures, the denser CaCl2 solution almost completely displaced the NaCO3 solution, causing strong localization of precipitates. However, in the horizontal fractures, flow stratification occurred in the 2 mm aperture fractures, with the less dense Na2CO3 flowing over the CaCl2 solution, resulting in a more even distribution of precipitates cross the fracture plane. P-wave amplitudes increased up to 8% and the arrival time decreased with precipitate accumulation in the horizontal fracture. This is consistent with a three-layered approach as the seismic impedance inside the fracture increases. The initial contact between the two was observed as a decrease in the P-wave amplitude. As precipitates accumulated, the amplitude recovered and increased, with greater increases observed along the mixing flow path. Fractures in the subsurface may seal differently depending on the orientation thus affecting the ability of a fracture to self-heal if oriented vertically. This work was supported by the Center for Nanoscale Controls on Geologic CO (NCGC), an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Basic Energy Sciences under Award # DE-AC02-05CH11231

  9. Dynamic Fracture Toughness Evaluation by Measurement of CTOD (Crack Tip Opening Displacement).

    DTIC Science & Technology

    1988-03-15

    fracture toughness of structural steels were reported by Shoemaker and Rolfe [1]; these and similar results are also presented in the text by Rolfe and...8217 MPaV/-m/s. Following the dynamic tests of Shoemaker and Rolfe , extensions of the familiar ASTM E-399 static fracture toughness tests were examined. This...s.V.: **.4* .4 5, -~ 5 5 - 𔃿 .4.4 References [1] Shoemaker, A.K. and Rolfe , S.T., "The Static and Dynamic Low-Temperature Crack-Toughness

  10. Tension band suture fixation for olecranon fractures.

    PubMed

    Phadnis, Joideep; Watts, Adam C

    2017-10-01

    Olecranon fractures are common and often require surgical treatment when displaced. Traditional methods of stabilization using tension band wire fixation and plate fixation achieve adequate union and function but are associated with a high rate of re-operation and wound problems because of prominent metalwork. The purpose of the present article is to describe an all suture technique for fixation of simple olecranon fractures that maintains inter-fragmentary compression, provides bony union and reduces the rate of re-operation caused by prominent metalwork.

  11. The initial safe range of motion of the ankle joint after three methods of internal fixation of simulated fractures of the medial malleolus.

    PubMed

    Shimamura, Yoshio; Kaneko, Kazuo; Kume, Kazuhiko; Maeda, Mutsuhiro; Iwase, Hideaki

    2006-07-01

    Previous studies have demonstrated the safe passive range of ankle motion for inter-bone stiffness after internal fixation under load but there is a lack of information about the safe range of ankle motion for early rehabilitation in the absence of loading. The present study was designed to assess the effect of ankle movement on inter-bone displacement characteristics of medial malleolus fractures following three types of internal fixation to determine the safe range of motion. Five lower legs obtained during autopsy were used to assess three types of internal fixation (two with Kirschner-wires alone; two with Kirschner-wires plus tension band wiring; and, one with an AO/ASIF malleolar screw alone). Following a simulated fracture by sawing through the medial malleolus the displacement between the fractured bone ends was measured during a passive range of movement with continuous monitoring using omega (Omega) shaped transducers and a biaxial flexible goniometer. Statistical analysis was performed with repeated measures analysis of variance. Inter-bone displacement was not proportional to the magnitude of movement throughout the range of ankle motion as, when separation exceeded 25 microm, there was increasingly wide separation as plantar-flexion or dorsal-flexion was increased. There was no statistical significant difference between the small amount of inter-bone displacement observed with three types of fixation within the safe range of dorsal-flexion and plantar-flexion for early rehabilitation. However the inter-bone separation when fixation utilized two Kirschner-wires alone tended to be greater than when using the other two types of fixation during dorsal-flexion and eversion. The present study revealed a reproducible range of ankle motion for early rehabilitation which was estimated to be within the range of 20 degrees of dorsal-flexion and 10 degrees of plantar-flexion without eversion. Also, internal fixation with two Kirschner-wires alone does not seem to provide stability achieved by the other two forms of fixation.

  12. Postoperative fever after hemiarthroplasty in elderly patients over 70 years of age with displaced femoral neck fracture: Necessity of routine workup?

    PubMed

    Yoo, Je-Hyun; Kim, Ki-Tae; Kim, Tae-Young; Hwang, Ji-Hyo; Chang, Jun-Dong

    2017-02-01

    Displaced femoral neck fracture in elderly patients has been treated with hemiarthroplasty as the treatment of choice. Fever following HA is common in these elderly patients. The aim of this study was to determine which post-HA fever workup could be beneficial in this group of patients. A total of 272 consecutive patients aged ≥70 years undergoing HA for displaced femoral neck fracture were retrospectively investigated. Postoperative fever (POF) was defined as any recorded body temperature ≥38°C in the early postoperative period. POF in each patient was characterized by the maximum temperature, the day of the first fever, and frequency of fever, stratified as either single or multiple fever spikes. Medical records were reviewed to identify positive fever workups and febrile complications. Of 272 patients, 135 (49.6%) developed POF. A total of 428 routine diagnostic tests were performed in all patients with POF, of which only 57 tests (13.3%) were positive. Urinalysis showed the highest positive rate (21.9%), followed by urine culture (14.3%), chest x-ray (12.6%), and blood culture (1.1%). The most common febrile complication was pneumonia (12.6%), followed by urinary tract infection (8.1%). On multivariate logistic regression for positive workups, only fever after postoperative day (POD) 2 was a risk factor for positive chest x-ray (OR 3.86, p=0.016) and urine culture (OR 5.04, p=0.019). Moreover, fever after POD 2 (OR 6.93, p<0.0001) and multiple fever spikes (OR 2.92, p=0.026) were independent predictors of infectious febrile complications. Routine workup for POF following hemiarthroplasty in elderly patients with displaced femoral neck fracture is not warranted. However, for fever after POD 2 and multiple fever spikes, chest x-ray and urinalysis would be necessary to rule out the two most common febrile complications such as pneumonia and urinary tract infection. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Unicameral bone cyst of a cervical vertebral body and lateral mass with associated pathological fracture in a child. Case report and review of the literature.

    PubMed

    Snell, B E; Adesina, A; Wolfla, C E

    2001-10-01

    The authors present the case of a 10-year-old girl with a history of cervical trauma in whom a cystic lesion was found to involve all three columns of C-7 with evidence of pathological fracture. Computerized tomography scanning revealed a lytic lesion with sclerotic margins involving the left vertebral body, pedicle, lateral mass, and lamina of C-7 with an associated pathological compression fracture. Magnetic resonance imaging demonstrated mixed signal on both T1- and T2-weighted sequences, with cystic and enhancing solid portions. Magnetic resonance angiography demonstrated anterior displacement of the left vertebral artery at C-7. The patient underwent C-7 subtotal corpectomy and posterior resection of the tumor mass; anterior and posterior fusion were performed in which instrumentation was placed. Histological examination disclosed cystic areas lined by fibromembranous tissue with calcification and osteoid deposits consistent with unicameral bone cyst. Of the four previously reported cases of unicameral bone cysts in the cervical spine, none involved all three columns simultaneously or was associated with pathological fracture. The most common differential diagnostic considerations for cystic lesions in the spine are aneurysmal bone cyst, osteoblastoma, or giant cell tumor of bone. Unicameral bone cyst, in this location, although rare, must be considered in the differential diagnosis and may require resection and spinal reconstruction.

  14. Mechanical properties of carbon fibre-reinforced polymer/magnesium alloy hybrid laminates

    NASA Astrophysics Data System (ADS)

    Zhou, Pengpeng; Wu, Xuan; Pan, Yingcai; Tao, Ye; Wu, Guoqing; Huang, Zheng

    2018-04-01

    In this study, we prepared fibre metal laminates (FMLs) consisting of high-modulus carbon fibre-reinforced polymer (CFRP) prepregs and thin AZ31 alloy sheets by using hot-pressing technology. Tensile and low-velocity impact tests were performed to evaluate the mechanical properties and fracture behaviour of the magnesium alloy-based FMLs (Mg-FMLs) and to investigate the differences in the fracture behaviour between the Mg-FMLs and traditional Mg-FMLs. Results show that the Mg-FMLs exhibit higher specific tensile strength and specific tensile modulus than traditional Mg-FMLs and that the tensile behaviour of the Mg-FMLs is mainly governed by the CFRP because of the combination of high interlaminar shear properties and thin magnesium alloy layers. The Mg-FMLs exhibit excellent bending stiffness. Hence, no significant difference between the residual displacement d r and indentation depth d i , and the permanent deformation is mainly limited to a small zone surrounding the impact location after the impact tests.

  15. Development of Ren Qiou fractured carbonate oil pools by water injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Z.; Li, G.

    1982-01-01

    This work gives a brief description on the geologic characteristics of Ren Qiou oil field and its development. Different methods have been used in its reservoir engineering study such as outcrop investigation, fracture and crevice description in tunnels, observation on core samples and their statistical data, thin section observation, casting section, fluorescence section, scanning electron microscope, mercury injection and withdrawal, down-hole television, and geophysical well logging. Physical modeling, 3-dimensional numeric simulation and reservoir performance analysis, and production profiles by production logging in an open hole, have been used to study mechanics of displacing oil by water and the movement ofmore » oil and water in reservoir pools production technologies with double-porosity. Pressure maintenance by bottomwater injection to keep producing wells flowing, acidization with emulsifying acid to penetrate deeply into the reservoir formation, and water plugging with chemical agent, have been used to maintain a consistent annual recovery rate. 11 references.« less

  16. Spinopelvic dissociation: multidetector computed tomographic evaluation of fracture patterns and associated injuries at a single level 1 trauma center.

    PubMed

    Gupta, Pushpender; Barnwell, Jonathan C; Lenchik, Leon; Wuertzer, Scott D; Miller, Anna N

    2016-06-01

    The objective of the present study is to evaluate multidetector computed tomographic (MDCT) fracture patterns and associated injuries in patients with spinopelvic dissociation (SPD). Our institutional trauma registry database was reviewed from Jan. 1, 2006, to Sept. 30, 2012, specifically evaluating patients with sacral fractures. MDCT scans of patients with sacral fractures were reviewed to determine the presence of SPD. SPD cases were characterized into the following fracture patterns: U-shaped, Y-shaped, T-shaped, H-shaped, and burst. The following MDCT features were recorded: level of the horizontal fracture, location of vertical fracture, kyphosis between major fracture fragments, displacement of fracture fragment, narrowing of central spinal canal, narrowing of neural foramina, and extension into sacroiliac joints. Quantitative evaluation of the sacral fractures was performed in accordance with the consensus statement by the Spine Trauma Study Group. Medical records were reviewed to determine associated pelvic and non-pelvic fractures, bladder and bowel injuries, nerve injuries, and type of surgical intervention. Twenty-one patients had SPD, of whom 13 were men and eight were women. Mean age was 41.8 years (range 18.8 to 87.7). Five fractures (24 %) were U-shaped, six (29 %) H-shaped, four (19 %) Y-shaped, and six (29 %) burst. Nine patients (43 %) had central canal narrowing, and 19 (90 %) had neural foramina narrowing. Eleven patients (52 %) had kyphotic angulation between major fracture fragments, and seven patients (33 %) had either anterior (24 %) or posterior (10 %) displacement of the proximal fracture fragment. Fourteen patients (67 %) had associated pelvic fractures, and 20 (95 %) had associated non-pelvic fractures. Two patients (10 %) had associated urethral injuries, and one (5 %) had an associated colon injury. Seven patients (33 %) had associated nerve injuries. Six patients (29 %) had surgical fixation while 15 (71 %) were managed non-operatively. On trauma MDCT examinations, patients with SPD have characteristic fracture patterns. It is important to differentiate SPD from other pelvic ring injuries due to high rate of associated injuries. Although all SPD injuries are unstable and need fixation, the decision for operative management in an individual patient depends on the systemic injury pattern, specific fracture pattern, and the ability to attain stable screw fixation.

  17. Biomechanical Comparison of Arthroscopic Single- and Double-Row Repair Techniques for Acute Bony Bankart Lesions.

    PubMed

    Spiegl, Ulrich J; Smith, Sean D; Todd, Jocelyn N; Coatney, Garrett A; Wijdicks, Coen A; Millett, Peter J

    2014-08-01

    Single- and double-row arthroscopic reconstruction techniques for acute bony Bankart lesions have been described in the literature. The double-row fixation technique would provide superior reduction and stability of a simulated bony Bankart lesion at time zero in a cadaveric model compared with the single-row technique. Controlled laboratory study. Testing was performed on 14 matched pairs of glenoids with simulated bony Bankart fractures with a defect width of 25% of the glenoid diameter. Half of the fractures were repaired with a double-row technique, while the contralateral glenoids were repaired with a single-row technique. The quality of fracture reduction was measured with a coordinate measuring machine. To determine the biomechanical stability of the repairs, specimens were preconditioned with 10 sinusoidal cycles between 5 and 25 N at 0.1 Hz and then pulled to failure in the anteromedial direction at a rate of 5 mm/min. Loads at 1 mm and 2 mm of fracture displacement were determined. The double-row technique required significantly higher forces to achieve fracture displacements of 1 mm (mean, 60.6 N; range, 39.0-93.3 N; P = .001) and 2 mm (mean, 94.4 N; range, 43.4-151.2 N; P = .004) than the single-row technique (1 mm: mean, 30.2 N; range, 14.0-54.1 N and 2 mm: mean, 63.7 N; range, 26.6-118.8 N). Significantly reduced fracture displacement was seen after double-row repair for both the unloaded condition (mean, 1.1 mm; range, 0.3-2.4 mm; P = .005) and in response to a 10-N anterior force applied to the defect (mean, 1.6 mm; range, 0.5-2.7 mm; P = .001) compared with single-row repair (unloaded: mean, 2.1 mm; range, 1.3-3.4 mm and loaded: mean, 3.4 mm; range, 1.9-4.7 mm). The double-row fixation technique resulted in improved fracture reduction and superior stability at time zero in this cadaveric model. This information may influence the surgical technique used to treat large osseous Bankart fractures and the postoperative rehabilitation protocols implemented when such repair techniques are used. © 2014 The Author(s).

  18. An efficient hydro-mechanical model for coupled multi-porosity and discrete fracture porous media

    NASA Astrophysics Data System (ADS)

    Yan, Xia; Huang, Zhaoqin; Yao, Jun; Li, Yang; Fan, Dongyan; Zhang, Kai

    2018-02-01

    In this paper, a numerical model is developed for coupled analysis of deforming fractured porous media with multiscale fractures. In this model, the macro-fractures are modeled explicitly by the embedded discrete fracture model, and the supporting effects of fluid and fillings in these fractures are represented explicitly in the geomechanics model. On the other hand, matrix and micro-fractures are modeled by a multi-porosity model, which aims to accurately describe the transient matrix-fracture fluid exchange process. A stabilized extended finite element method scheme is developed based on the polynomial pressure projection technique to address the displacement oscillation along macro-fracture boundaries. After that, the mixed space discretization and modified fixed stress sequential implicit methods based on non-matching grids are applied to solve the coupling model. Finally, we demonstrate the accuracy and application of the proposed method to capture the coupled hydro-mechanical impacts of multiscale fractures on fractured porous media.

  19. Lunate fractures and associated radiocarpal and midcarpal instabilities: a systematic review.

    PubMed

    Shunmugam, Meenalochani; Phadnis, Joideep; Watts, Amy; Bain, Gregory I

    2018-01-01

    The aim of this study was to analyse lunate fractures and any associated osseo-ligamentous injuries. A systematic review identified 34 cases. We identified carpal instabilities at the radiocarpal and midcarpal joints in volar and dorsal directions. Radiocarpal instabilities (10/34) were usually dorsoradial (8/10), with a transverse lunate fracture, best seen on a coronal image. Midcarpal instabilities (24/34) were usually volar (14/18), with a volar lunate shear fracture, best seen on a sagittal image. Instabilities were sub-classified into non-displaced, subluxated and dislocated. Associated fractures of the scaphoid and the radial and ulnar styloid processes were common. Lunate fractures without subluxation or dislocation had good outcomes with cast immobilization or fixation of associated fractures. Lunate fracture-subluxations are unstable injuries that are best managed with fixation of the carpal fractures. Lunate fracture-dislocations are complex injuries, requiring stabilization of the lunate, associated fractures and ligament injuries; complications are common and acute or delayed salvage procedures may be required.

  20. Analysis of occupant kinematics and dynamics in nearside oblique impacts.

    PubMed

    López-Valdés, F J; Juste-Lorente, O; Maza-Frechin, M; Pipkorn, B; Sunnevang, C; Lorente, A; Aso-Vizan, A; Davidsson, J

    2016-09-01

    The objective of this article is to analyze the kinematics and dynamics of restrained postmortem human surrogates (PMHS) exposed to a nearside oblique impact and the injuries that were found after the tests. Three male PMHS of similar age (64 ± 4 years) and anthropometry (weight: 61 ± 9.6 kg; stature: 172 ± 2.7 cm) were exposed to a 30° nearside oblique impact at 34 km/h. The test fixture approximated the seating position of a front seat occupant. A rigid seat was designed to match the pelvic displacement in a vehicle seat. Surrogates were restrained by a 3-point seat belt consisting of a 2 kN pretensioner (PT), 4.5 kN force-limiting shoulder belt, and a 3.5 kN PT lap belt. The shoulder belt PT was not fired in one of the tests. Trajectories of the head, shoulder, and hip joint (bilaterally) were recorded at 1,000 Hz by a 3D motion capture system. The 3D acceleration and angular rate of the head, T1, and pelvis, and the 3D acceleration of selected spinal locations was measured at 10,000 Hz. Seat belt load cells measured the belt tension at 4 locations. PMHS donation and handling were performed with the approval of the relevant regional ethics review board. Activation of the shoulder PT reduced substantially the peak forward excursion of the head but did not influence the lateral displacement of the head center of gravity (CG). In all 3 subjects, the lateral excursion of the head CG (291.1, 290, 292.1 mm) was greater than the forward displacement (271.4, 216.7, 171.5 mm). The hip joint excursion of the PMHS that was not exposed to the shoulder PT seat belt was twice the magnitude observed for the other 2 subjects. The 3 PMHS sustained clavicle fractures on the shoulder loaded by the seat belt and 2 of them were diagnosed atlantoaxial subluxation in the radiologist examination. Avulsion fractures of the right lamina of T1, T2, T3, and T4 were found when the PT was not used. The 3 PMHS received multiple fractures spread over both aspects of the rib cage and involving the posterior aspect of it. In this study of nearside oblique impact loading, the PMHS exhibited kinematics characterized by reduced torso pitching and increased lateral head excursion as compared to previous frontal impact results. These kinematics resulted in potential cervical and thoracic spinal injuries and in complete, displaced fractures of the lateral and posterior aspects of the rib cage. Though this is a limited number of subjects, it shows the necessity of further understanding of the kinematics of occupants exposed to this loading mode.

  1. Polyaxial Screws in Locked Plating of Tibial Pilon Fractures.

    PubMed

    Yenna, Zachary C; Bhadra, Arup K; Ojike, Nwakile I; Burden, Robert L; Voor, Michael J; Roberts, Craig S

    2015-08-01

    This study examined the axial and torsional stiffness of polyaxial locked plating techniques compared with fixed-angle locked plating techniques in a distal tibia pilon fracture model. The effect of using a polyaxial screw to cross the fracture site was examined to determine its ability to control relative fracture site motion. A laboratory experiment was performed to investigate the biomechanical stiffness of distal tibia fracture models repaired with 3.5-mm anterior polyaxial distal tibial plates and locking screws. Sawbones Fourth Generation Composite Tibia models (Pacific Research Laboratories, Inc, Vashon, Washington) were used to model an Orthopaedic Trauma Association 43-A1.3 distal tibia pilon fracture. The polyaxial plates were inserted with 2 central locking screws at a position perpendicular to the cortical surface of the tibia and tested for load as a function of axial displacement and torque as a function of angular displacement. The 2 screws were withdrawn and inserted at an angle 15° from perpendicular, allowing them to span the fracture and insert into the opposing fracture surface. Each tibia was tested again for axial and torsional stiffness. In medial and posterior loading, no statistically significant difference was found between tibiae plated with the polyaxial plate and the central screws placed in the neutral position compared with the central screws placed at a 15° position. In torsional loading, a statistically significant difference was noted, showing greater stiffness in tibiae plated with the polyaxial plate and the central screws placed at a 15° position compared with tibiae plated with the central screws placed at a 0° (or perpendicular) position. This study showed that variable angle constructs show similar stiffness properties between perpendicular and 15° angle insertions in axial loading. The 15° angle construct shows greater stiffness in torsional loading. Copyright 2015, SLACK Incorporated.

  2. Fracture process zone in granite

    USGS Publications Warehouse

    Zang, A.; Wagner, F.C.; Stanchits, S.; Janssen, C.; Dresen, G.

    2000-01-01

    In uniaxial compression tests performed on Aue granite cores (diameter 50 mm, length 100 mm), a steel loading plate was used to induce the formation of a discrete shear fracture. A zone of distributed microcracks surrounds the tip of the propagating fracture. This process zone is imaged by locating acoustic emission events using 12 piezoceramic sensors attached to the samples. Propagation velocity of the process zone is varied by using the rate of acoustic emissions to control the applied axial force. The resulting velocities range from 2 mm/s in displacement-controlled tests to 2 ??m/s in tests controlled by acoustic emission rate. Wave velocities and amplitudes are monitored during fault formation. P waves transmitted through the approaching process zone show a drop in amplitude of 26 dB, and ultrasonic velocities are reduced by 10%. The width of the process zone is ???9 times the grain diameter inferred from acoustic data but is only 2 times the grain size from optical crack inspection. The process zone of fast propagating fractures is wider than for slow ones. The density of microcracks and acoustic emissions increases approaching the main fracture. Shear displacement scales linearly with fracture length. Fault plane solutions from acoustic events show similar orientation of nodal planes on both sides of the shear fracture. The ratio of the process zone width to the fault length in Aue granite ranges from 0.01 to 0.1 inferred from crack data and acoustic emissions, respectively. The fracture surface energy is estimated from microstructure analysis to be ???2 J. A lower bound estimate for the energy dissipated by acoustic events is 0.1 J. Copyright 2000 by the American Geophysical Union.

  3. Surgical treatment of displaced intra-articular calcaneal fracture using a single small lateral approach

    PubMed Central

    El-Adl, Gamal; Hassanin, Ehab Y.; Abdellatif, M-Serry

    2010-01-01

    The objective of this study was to evaluate the outcome of semi-open reduction and minimal internal fixation through a single small lateral approach as a minimally invasive technique for treatment of displaced intra-articular calcaneal fractures. This prospective study was conducted on eighteen patients (16 men and 2 women). The average age was 37.7 (22–55). The most common cause of injury was a fall from height in fourteen patients. Patients were operated on within a mean time of 4.8 days of admission (1–11 days) and were followed up for an average period of 24.1 months (6–39 months). Patients were evaluated clinically using the Creighton-Nebraska Heath Foundation Assessment score of Crosby and Fitzgibbons (J Bone Joint Surg (Am) 72-A:852–859, 1990). The scoring system proposed by Knirk and Jupiter was used for radiological assessment of the posterior subtalar joint (Knirk and Jupiter in J Bone Joint Surg (Am) 68-A: 647–659, 1986). The skin incision healed in all cases without necrosis, infection, or sural nerve injury. All fractures healed after an average of 8 weeks (7–10 weeks), and patients returned to the routine daily activities after an average time of 4.3 months (3–7 months). In conclusion, semi-open reduction and minimal internal fixation through a small lateral approach is an effective treatment for carefully selected cases of displaced intra-articular calcaneal fractures. PMID:21811904

  4. Reverse total shoulder arthroplasty for acute head-splitting, 3- and 4-part fractures of the proximal humerus in the elderly.

    PubMed

    Grubhofer, Florian; Wieser, Karl; Meyer, Dominik C; Catanzaro, Sabrina; Beeler, Silvan; Riede, Ulf; Gerber, Christian

    2016-10-01

    Anatomic reduction and stable internal fixation of complex proximal humeral fractures in the elderly is challenging. Secondary displacement, screw perforation, and humeral head necrosis are common complications. The outcome of hemiarthroplasty is unpredictable and strongly dependent on the uncertain healing of the greater tuberosity. This multicenter study retrospectively analyzes the midterm results of primary reverse total shoulder arthroplasty for the treatment of acute, complex fractures of the humerus in an elderly population. Fifty-two shoulders in 51 patients with a mean age of 77 years treated with reverse total shoulder arthroplasty for an acute, complex fracture of the proximal humerus were clinically and radiographically analyzed after a mean follow-up period of 35 months (range, 12-90 months). There were no intraoperative complications. Revision surgery was performed in 4 shoulders. At final follow-up, the absolute and relative Constant scores averaged 62 points (range, 21-83 points) and 86% (range, 30%-100%), respectively, with a mean Subjective Shoulder Value of 83% (range, 30%-100%). Of the patients, 92% rated the treatment outcome as excellent or good. Patients with a resected or secondarily displaced greater tuberosity had an inferior clinical outcome to those with a healed greater tuberosity. The midterm clinical results are predictably good, with low complication rates and a rapid postoperative recovery of painfree everyday function. If secondary displacement of the greater tuberosity occurs, revision surgery may warrant consideration in view of potential improvement of ultimate outcome. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Substantial vertebral body osteophytes protect against severe vertebral fractures in compression

    PubMed Central

    Aubin, Carl-Éric; Chaumoître, Kathia; Mac-Thiong, Jean-Marc; Ménard, Anne-Laure; Petit, Yvan; Garo, Anaïs; Arnoux, Pierre-Jean

    2017-01-01

    Recent findings suggest that vertebral osteophytes increase the resistance of the spine to compression. However, the role of vertebral osteophytes on the biomechanical response of the spine under fast dynamic compression, up to failure, is unclear. Seventeen human spine specimens composed of three vertebrae (from T5-T7 to T11-L1) and their surrounding soft tissues were harvested from nine cadavers, aged 77 to 92 years. Specimens were imaged using quantitative computer tomography (QCT) for medical observation, classification of the intervertebral disc degeneration (Thomson grade) and measurement of the vertebral trabecular density (VTD), height and cross-sectional area. Specimens were divided into two groups (with (n = 9) or without (n = 8) substantial vertebral body osteophytes) and compressed axially at a dynamic displacement rate of 1 m/s, up to failure. Normalized force-displacement curves, videos and QCT images allowed characterizing failure parameters (force, displacement and energy at failure) and fracture patterns. Results were analyzed using chi-squared tests for sampling distributions and linear regression for correlations between VTD and failure parameters. Specimens with substantial vertebral body osteophytes present higher stiffness (2.7 times on average) and force at failure (1.8 times on average) than other segments. The presence of osteophytes significantly influences the location, pattern and type of fracture. VTD was a good predictor of the dynamic force and energy at failure for specimens without substantial osteophytes. This study also showed that vertebral body osteophytes provide a protective mechanism to the underlying vertebra against severe compression fractures. PMID:29065144

  6. Lateral clavicle fracture with coracoclavicular ligament injury: a biomechanical study of 4 different repair techniques.

    PubMed

    Alaee, Farhang; Apostolakos, John; Singh, Hardeep; Holwein, Christian; Diermeier, Theresa; Cote, Mark P; Beitzel, Knut; Imhoff, Andreas B; Mazzocca, Augustus D; Voss, Andreas

    2017-07-01

    To investigate the biomechanical performance of four different methods used for coracoclavicular (CC) ligament reconstruction in a lateral clavicle fracture repair. Native displacement, translation, and rotation at the acromioclavicular joint of 24 fresh-frozen cadaveric shoulders were tested. A reproducible fracture in the lateral third of the clavicle was created by dissecting both CC ligaments. Each specimen was then repaired with plate fixation of the fracture and the following CC repair technique: (1) Cortical button. (2) Suture anchor and plate button. (3) Suture anchor no plate button, and (4) Suture around coracoid. All reconstructed specimens were then re-tested for displacement, translation, and load to failure, and compared to their native results. Groups 1 and 3 were investigated for rotational load. There was no difference in load to failure between the repaired groups (p: ns). Group 1 showed less superior and anterior translations (p < 0.05). Group 2 showed significantly less superior translation (p = 0.003), but no significance with anterior and posterior translations to the native joint. Group 3 showed less superior and posterior translations (p = 0.005 and p = 0.039). Anterior and posterior translations were increased in group 4 (p < 0.05). The biomechanical analyses did not show any significance in load to failure or displacement after cyclic loading among the study groups. All repairs were effective in preventing superior translation. Groups 1 and 2 demonstrated increased horizontal stability compared to the native state. All 4 methods are clinically viable options for CC ligament repair.

  7. Stress inversion using borehole images and geometry evolution of the fractures in the Rittershoffen EGS project (Alsace, France).

    NASA Astrophysics Data System (ADS)

    Azzola, Jérôme; Valley, Benoît; Schmittbuhl, Jean; Genter, Albert; Hehn, Régis

    2017-04-01

    In the Upper Rhine Graben, several deep geothermal projects based on the Enhanced Geothermal System (EGS) exploit local geothermal reservoirs. The principle underlying this technology consists of increasing the hydraulic performances of the reservoir by stimulating natural fractures using different methods, in order to extract hot water with commercially flow rates. In this domain, the knowledge of the in-situ stress state is of central importance to predict the response of the rock mass to stimulations. Here we characterized the stress tensor from Ultrasonic Borehole Imager (UBI) in the open hole section of the EGS doublet located in Rittershoffen, France (in the Upper Rhine Graben). Interestingly extensive logging programs were leaded at different key moments of the development of the injection well using hydraulic, thermal and chemical stimulation (Baujard et al., 2017)1. The time lapse UBI dataset consists of images of the injection well before, shortly and lastly after the stimulation. The geometry of the induced fractures in compression (breakouts) picked on the UBI images are used to determine the orientation of the in-situ stress tensor. The magnitude of the principal stresses is deduced from the drilling data. The magnitude of the maximum horizontal principal stress is evaluated using an inversion method with three failure criteria (Mohr-Coulomb, Mogi-Coulomb and modified Hoek-Brown criterion) and under the assumption of a vertical or a deviated well. Moreover, the characteristic of the dataset enables the analysis of the evolution of the borehole fracturing, as the deepening or widening of the induced fractures. The correlation of the UBI image allows firstly to determine the tool trajectory and to adapt the post and pre-stimulation images. It secondly leads to the estimation of a complete displacement field which characterizes the deformation induced by the stimulations. Even if the variable image quality deeply conditions the comparison, the considered dataset enabled a consistent evaluation of the in-situ stress field taking place in the underground of the EGS plant, as showed by the comparison to results obtained in the vicinity. Moreover, the study of the evolution of fracturing shows the influence of the stimulation process on the fractures geometry. 1(Baujard, C., Genter, A., Dalmais, E., Maurer, V., Hehn, R., Rosillette, R., Vidal, J., Schmittbuhl, J., 2017). Hydrothermal Characterization of wells GRT-1 and GRT-2 in Rittershoffen, France: Implications on the understanding of natural flow systems in the Rhine Graben, Geothermics, 65, 255-268.

  8. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    PubMed

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  9. Primary total hip replacement for displaced subcapital fractures of the femur.

    PubMed

    Taine, W H; Armour, P C

    1985-03-01

    The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.

  10. Open reduction and internal fixation of osteoporotic acetabular fractures through the ilio-inguinal approach: use of buttress plates to control medial displacement of the quadrilateral surface.

    PubMed

    Peter, Robin E

    2015-01-01

    The number of acetabular fractures in the geriatric population requiring open reduction and internal fixation is increasing. Fractures with medial or anterior displacement are the most frequent types, and via the ilio-inguinal approach buttress plates have proved helpful to maintain the quadrilateral surface or medial acetabular wall. Seven to ten hole 3.5 mm reconstruction plates may be used as buttress plates, placed underneath the usual pelvic brim plate. This retrospective study presents our results with this technique in 13 patients at a minimum follow-up of 12 months (average, 31 months). 85% of the patients had a good result. The early onset of post-traumatic osteoarthritis necessitated total hip arthroplasty in two patients (15%) at 12 and 18 months follow-up, respectively. This treatment option should be considered in the surgeon's armamentarium when fixing these challenging cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Intramedullary reduction and stabilisation of adult radial neck fractures.

    PubMed

    Keller, H W; Rehm, K E; Helling, J

    1994-05-01

    We report the treatment of six adult patients with displaced fractures of the radial neck by intramedullary reduction and stabilisation. Nine months after operation all the patients had good joint function, little or no pain, complete healing and no significant periarticular calcification. This simple semi-closed procedure may help to avoid resection of the radial head in some cases.

  12. Avascular necrosis of the femoral head after osteosynthesis of femoral neck fracture.

    PubMed

    Min, Byung-Woo; Kim, Sung-Jin

    2011-05-18

    The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. We evaluated the incidence of avascular necrosis of the femoral head with the use of contemporary techniques for femoral neck fracture fixation. We then sought to determine what potential risk factors influenced the development of avascular necrosis.Between 1990 and 2005, one hundred sixty-three intracapsular femoral neck fractures in 163 patients were treated with internal fixation at our level-I trauma center. All patients were monitored until conversion to total hip arthroplasty or for a minimum of 2 years postoperatively. Ten patients (10 hips) died and 7 patients (7 hips) were lost to follow-up. The remaining 146 patients (146 hips) had a mean 5.2 years of follow-up (range, 3 months to 17 years). The incidence of avascular necrosis was 25.3% (37 hips). The average time to diagnosis of avascular necrosis was 18.8 months (range, 3-47 months). Patient sex, age, interval from injury to surgery, and mechanism of injury were statistically not associated with the development of avascular necrosis. The quality of fracture reduction, adequacy of fixation, degree of displacement, and comminution of the posterior cortex were significantly associated. After we controlled for patient and radiographic characteristics, multivariate analyses indicated that the important predictors for avascular necrosis are poor reduction (odds ratio=13.889) and initial displacement of the fracture (odds ratio=4.693). Copyright 2011, SLACK Incorporated.

  13. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    PubMed

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. Clip gage attachment for frictionless measurement of displacement during high-temperature mechanical testing

    DOEpatents

    Alexander, David J.

    1994-01-01

    An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical.

  15. Static and dynamic strain energy release rates in toughened thermosetting composite laminates

    NASA Technical Reports Server (NTRS)

    Cairns, Douglas S.

    1992-01-01

    In this work, the static and dynamic fracture properties of several thermosetting resin based composite laminates are presented. Two classes of materials are explored. These are homogeneous, thermosetting resins and toughened, multi-phase, thermosetting resin systems. Multi-phase resin materials have shown enhancement over homogenous materials with respect to damage resistance. The development of new dynamic tests are presented for composite laminates based on Width Tapered Double Cantilevered Beam (WTDCB) for Mode 1 fracture and the End Notched Flexure (ENF) specimen. The WTDCB sample was loaded via a low inertia, pneumatic cylinder to produce rapid cross-head displacements. A high rate, piezo-electric load cell and an accelerometer were mounted on the specimen. A digital oscilloscope was used for data acquisition. Typical static and dynamic load versus displacement plots are presented. The ENF specimen was impacted in three point bending with an instrumented impact tower. Fracture initiation and propagation energies under static and dynamic conditions were determined analytically and experimentally. The test results for Mode 1 fracture are relatively insensitive to strain rate effects for the laminates tested in this study. The test results from Mode 2 fracture indicate that the toughened systems provide superior fracture initiation and higher resistance to propagation under dynamic conditions. While the static fracture properties of the homogeneous systems may be relatively high, the apparent Mode 2 dynamic critical strain energy release rate drops significantly. The results indicate that static Mode 2 fracture testing is inadequate for determining the fracture performance of composite structures subjected to conditions such as low velocity impact. A good correlation between the basic Mode 2 dynamic fracture properties and the performance is a combined material/structural Compression After Impact (CAI) test is found. These results underscore the importance of examining rate-dependent behavior for determining the longevity of structures manufactured from composite materials.

  16. [Treatment of enophthalmos after severe malar-maxillary complex fracture with titanium mesh and high density polyethylene (Medpor)].

    PubMed

    Zhao, Yan-feng; Lu, Ping; Zhou, Xiao-nan; Qu, Chang-feng

    2010-03-01

    To study the surgical management of enophthalmos after severe malar maxillary complex fracture. The X-ray and CT examination were performed before operation to diagnose the orbital fracture and intraorbital tissue displacement. The fractured orbital rim was repositioned intraoperatively, followed by implantation of shaped titanium mesh to rebuild the orbital floor. The Medpor was inserted above the titanium mesh to correct the enophthalmos. From Sept. 2007 to Jan. 2009, 6 cases of enophthalmos after severe malar-maxillary complex fracture were treated. The enophthalmos was corrected or improved obviously in all the patients. The enophthalmos after severe malar-maxillary complex fracture can be corrected or obviously improved. Shaped titanium mesh can be used to rebuild the orbital floor with the Medpor to reconstruct the intraorbital tissue volume.

  17. High resolution monitoring of hydrology and deformation in a unstable slope

    NASA Astrophysics Data System (ADS)

    Nevers, Pierre; Provost, Floriane; Kromer, Ryan; Bertrand, Catherine; Malet, Jean-Philippe; Marc, Vincent; Gaillardet, Jérôme; Gance, Julien; Abellan, Antonio; Jaboyedoff, Michel

    2017-04-01

    The Séchilienne landslide is located on the right bank of the Romanche River, South East of Grenoble (Isère, France). The active zone of the gravitational instability involves several millions of cubic meters. The geology consists in fractured hard rocks (micaschists) with double permeability and strong spatial heterogeneities. The deformation of the unstable slope is monitored by on-site extensometric gauges, inclinometers, GNSS and remotely by a terrestrial radar and a total station. Hydro-chemio-mechanical processes controlling the reactivation of the landslide are influenced by the evolution of the landslide deformation in space and time, and the water circulation in the highly heterogeneous fractured media. A hydrogeochemical monitoring of the unsaturated zone in the fractured hard rock has been carried out since 2010. This monitoring is supported by the French Landslide Observatory (OMIV) and consists in continuous measurements of physico-chemical parameters on two groundwater outlets (T°C, EC, flow rate) and weekly samplings of the waters for quality monitoring. Water chemistry is a good proxy to locate in time and space the origin of the infiltrated water. This tool is used to understand the complex relationships between chemical weathering, hydromechanical changes and weakening/deformation of the unstable material. This monitoring indicates a correlation between water chemistry, rainwater infiltration and rock mass deformation highlighting the impacts of rock-water interactions on the landslide dynamics. But a distributed information over area is still needed because the heterogeneities of the slope and the few sampling points currently prevent a detailed understanding of the global mechanisms involved. To better understand and constrain the hydrogeological and hydro-chemio-mechanical behavior of the slope, a multi-method monitoring of a flood wave infiltration has been carried out in early 2016 in order to distinguish possible signals related to significant displacements. Displacements were monitored by a GB-InSAR and a terrestrial laser scanner in order to obtain a global image of the deformation at high frequency (less than 1 hour). Repeated time-lapse geoelectrical profiles along four sections have been acquired each two hours on relevant plots which are suspected to be the main water flow paths from the surface to the depth. Water quality changes were monitored at high frequency in order to provide information on the water residence time. This first dataset gives insight into the moving volumes of rock and fluids. Imagery geophysics identifies a signal of fluid circulation in a fracture with a fast transit. The chemical signal identifies the heterogeneous functioning of the drainage system (drain/low permeable structure) with a fast transit.

  18. Etude hydromecanique d'une fracture en cisaillement sous contrainte normale constante

    NASA Astrophysics Data System (ADS)

    Lamontagne, Eric

    This research study deals with the effects of shear direction and injection flow rate on the flow directional anisotropy for a given normal stress. It presents experimental works on hydromechanical shear behaviour of a fracture under constant normal stress conditions that permits the characterisation of the intrinsic hydraulic transmissivity in relation with the directional anisotropy of the roughness morphology on the fracture surfaces. Tests were performed on mortar replicas of a natural fracture so that the fracture roughness and void space geometry were kept the same for each test. The experimental work program was performed through direct shear tests on the fracture replicas in four shear directions under four constant normal stress levels. The application of the normal stress was followed by several injections of fluid under constant flow rate. Then, for each defined shear displacement, several injections of fluid were done at different flow rate but under constant flow rate. The test results show that: (1) for the whole shear tests, the global intrinsic transmissivity is included within an enveloping zone of about one order of size. The transmissivity curves within the enveloping zone has a particularity to increase about two orders of size in the first millimetre of shear displacement and subsequently stabilised rapidly; (2) the highest dilatancy do not correspond necessarily with the highest intrinsic transmissivity so that, the behaviour of the global intrinsic transmissivity is not directly proportional to the fracture dilatancy during shear; (3) after the peak shear stress, the divergence is more marked between the global intrinsic transmissivity curves at various flow rate; (4) after peak shear strength and the beginning of asperity degradation, the gradual passage to residual friction shear behaviour causes a directional flow anisotropy and a reorientation of the flow chenalisation direction sub perpendicularly to the shear direction; (5) the anisotropy is not to develop equally between the two sense in the perpendicular direction to shear direction. In order to characterise the dynamics of the flow pattern in the fracture, a statistical analysis of the surfaces morphology of the fracture and the casting of void space geometry were performed before and after shear. A statistical analysis of asperity heights, on the global scale of the fracture surfaces, permits to characterise the fracture morphology and put in evidence a large morphological structure on which are superposed smaller asperities of variable dimensions. This large dimension structure generate a higher level landing occupying more than half of the fracture area. The study of the surfaces morphology of the fracture, performed with the geostatistical mean asperity heights variogram by direction before shearing, show the presence of two entangled morphologic structure families (28 and 15 mm). This same study done after shearing shows that the asperity degradation seems associated with the reduction of the global intrinsic transmissivity of the fracture. Finally, the void spaces morphology evaluated by casting techniques, during the shear tests, has permitted to verify the contacts evolution with the increasing shear displacement and visualised flow chenalisation during fracture shearing.

  19. The Shear Mechanisms of Natural Fractures during the Hydraulic Stimulation of Shale Gas Reservoirs.

    PubMed

    Zhang, Zhaobin; Li, Xiao

    2016-08-23

    The shearing of natural fractures is important in the permeability enhancement of shale gas reservoirs during hydraulic fracturing treatment. In this work, the shearing mechanisms of natural fractures are analyzed using a newly proposed numerical model based on the displacement discontinuities method. The fluid-rock coupling system of the model is carefully designed to calculate the shearing of fractures. Both a single fracture and a complex fracture network are used to investigate the shear mechanisms. The investigation based on a single fracture shows that the non-ignorable shearing length of a natural fracture could be formed before the natural fracture is filled by pressurized fluid. Therefore, for the hydraulic fracturing treatment of the naturally fractured shale gas reservoirs, the shear strength of shale is generally more important than the tensile strength. The fluid-rock coupling propagation processes of a complex fracture network are simulated under different crustal stress conditions and the results agree well with those of the single fracture. The propagation processes of complex fracture network show that a smaller crustal stress difference is unfavorable to the shearing of natural fractures, but is favorable to the formation of complex fracture network.

  20. The Shear Mechanisms of Natural Fractures during the Hydraulic Stimulation of Shale Gas Reservoirs

    PubMed Central

    Zhang, Zhaobin; Li, Xiao

    2016-01-01

    The shearing of natural fractures is important in the permeability enhancement of shale gas reservoirs during hydraulic fracturing treatment. In this work, the shearing mechanisms of natural fractures are analyzed using a newly proposed numerical model based on the displacement discontinuities method. The fluid-rock coupling system of the model is carefully designed to calculate the shearing of fractures. Both a single fracture and a complex fracture network are used to investigate the shear mechanisms. The investigation based on a single fracture shows that the non-ignorable shearing length of a natural fracture could be formed before the natural fracture is filled by pressurized fluid. Therefore, for the hydraulic fracturing treatment of the naturally fractured shale gas reservoirs, the shear strength of shale is generally more important than the tensile strength. The fluid-rock coupling propagation processes of a complex fracture network are simulated under different crustal stress conditions and the results agree well with those of the single fracture. The propagation processes of complex fracture network show that a smaller crustal stress difference is unfavorable to the shearing of natural fractures, but is favorable to the formation of complex fracture network. PMID:28773834

  1. Central tarsal bone fracture in the border collie.

    PubMed

    Guilliard, M

    2007-07-01

    Fracture of the plantar process of the central tarsal bone together with a dorsomedial displacement of the body of the bone was seen in six border collies. All injuries occurred during free exercise, with no extrinsic trauma. Three dogs had concomitant tarsal fractures. Primary treatment was by lag screwing the central tarsal bone to the fourth tarsal bone. All cases eventually made an excellent recovery. The superficial radiographic appearance was of a luxation of the bone as reported in a previous series, but appraisal of the radiographs showed evidence of fracture in all cases. A cadaver study to assess the mechanism of luxation showed that it is unlikely to occur naturally.

  2. Trauma patient adverse outcomes are independently associated with rib cage fracture burden and severity of lung, head, and abdominal injuries.

    PubMed

    Dunham, C Michael; Hileman, Barbara M; Ransom, Kenneth J; Malik, Rema J

    2015-01-01

    We hypothesized that lung injury and rib cage fracture quantification would be associated with adverse outcomes. Consecutive admissions to a trauma center with Injury Severity Score ≥ 9, age 18-75, and blunt trauma. CT scans were reviewed to score rib and sternal fractures and lung infiltrates. Sternum and each anterior, lateral, and posterior rib fracture was scored 1 = non-displaced and 2 = displaced. Rib cage fracture score (RCFS) = total rib fracture score + sternal fracture score + thoracic spine Abbreviated Injury Score (AIS). Four lung regions (right upper/middle, right lower, left upper, and left lower lobes) were each scored for % of infiltrate: 0% = 0; ≤ 20% = 1, ≤ 50% = 2, > 50% = 3; total of 4 scores = lung infiltrate score (LIS). Of 599 patients, 193 (32%) had 854 rib fractures. Rib fracture patients had more abdominal injuries (p < 0.001), hemo/pneumothorax (p < 0.001), lung infiltrates (p < 0.001), thoracic spine injuries (p = 0.001), sternal fractures (p = 0.0028) and death or need for mechanical ventilation ≥ 3 days (Death/Vdays ≥ 3) (p < 0.001). Death/Vdays ≥ 3 was independently associated with RCFS (p < 0.001), LIS (p < 0.001), head AIS (p < 0.001) and abdominal AIS (p < 0.001). Of the 193 rib fracture patients, Glasgow Coma Score 3-12 or head AIS ≥ 2 occurred in 43%. A lung infiltrate or hemo/pneumothorax occurred in 55%. Thoracic spine injury occurred in 23%. RCFS was 6.3 ± 4.4 and Death/Vdays ≥ 3 occurred in 31%. Death/Vdays ≥ 3 rates correlated with RCFS values: 19% for 1-3; 24% for 4-6; 42% for 7-12 and 65% for ≥ 13 (p < 0.001). Death/Vdays ≥ 3 was independently associated with RCFS (p = 0.02), LIS (p = 0.001), head AIS (p < 0.001) and abdominal AIS (p < 0.001). Death/Vdays ≥ 3 association was better for RCFS (p = 0.005) than rib fracture score (p = 0.08) or number of fractured ribs (p = 0.80). Rib fracture patients have increased risk for truncal injuries and adverse outcomes. Adverse outcomes are independently associated with rib cage fracture burden. Severity of head, abdominal, and lung injuries also influence rib fracture outcomes.

  3. Segond Fractures Are Not a Risk Factor for Anterior Cruciate Ligament Reconstruction Failure.

    PubMed

    Gaunder, Christopher L; Bastrom, Tracey; Pennock, Andrew T

    2017-12-01

    Segond fractures may be identified when an anterior cruciate ligament (ACL) tear is diagnosed and likely represent an avulsion of the anterolateral ligament. It is currently unclear whether these fractures can be ignored at the time of ACL reconstruction or if they should be addressed surgically. To compare the incidence of Segond fractures in patients undergoing primary ACL reconstruction compared with those undergoing revision ACL reconstruction in an attempt to determine if the presence of a Segond fracture predisposes to ACL reconstruction failure. Cross-sectional study; Level of evidence, 3. A retrospective review of all patients undergoing primary or revision ACL reconstruction between 2007 and 2014 was performed. Demographic data (age, sex, body mass index), injury variables (acuity, mechanism of injury), and radiographic features (concomitant ligamentous injuries, growth plate status) were documented. Each Segond fracture was analyzed for its specific location, size, displacement, and healing using both radiographs and magnetic resonance imaging. Statistical analysis was performed using a P value of <.05. A total of 552 patients underwent primary ACL reconstruction, and 47 patients underwent revision ACL reconstruction who met inclusion criteria. The incidence of Segond fractures was 6% in the primary reconstruction group. The fracture fragment averaged 6.6 mm in height and 2.3 mm in width and was displaced a mean of 5.0 mm. The fracture fragment bed was localized at the tibial attachment site of the anterolateral ligament a mean 20.6 mm posterior to the Gerdy tubercle in nearly all patients. After ACL reconstruction, the Segond fracture healed in 90% of patients. The incidence of Segond fractures was 3 times as common in male patients ( P = .02); otherwise, its presence was not associated with any other demographic data, injury variables, or radiographic features ( P > .05). No patients undergoing revision surgery had a Segond fracture, and no patient with a Segond fracture had graft failure. Patients with a Segond fracture are at no higher risk to require revision ACL reconstruction compared with patients without a Segond fracture. This may be attributable to its high union rate. At the time of primary ACL reconstruction, if a Segond fracture is identified, it can be ignored (not repaired or reconstructed), and this approach does not appear to predispose to early ACL graft failure.

  4. Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures: A Biomechanical Study.

    PubMed

    Reinhardt, Sophia; Martin, Heiner; Ulmar, Benjamin; Döbele, Stefan; Zwipp, Hans; Rammelt, Stefan; Richter, Martinus; Pompach, Martin; Mittlmeier, Thomas

    2016-08-01

    Open reduction and internal fixation with a plate is deemed to represent the gold standard of surgical treatment for displaced intra-articular calcaneal fractures. Standard plate fixation is usually placed through an extended lateral approach with high risk for wound complications. Minimally invasive techniques might avoid wound complications but provide limited construct stability. Therefore, 2 different types of locking nails were developed to allow for minimally invasive technique with sufficient stability. The aim of this study was to quantify primary stability of minimally invasive calcaneal interlocking nail systems in comparison to a variable-angle interlocking plate. After quantitative CT analysis, a standardized Sanders type IIB fracture model was created in 21 fresh-frozen cadavers. For osteosynthesis, 2 different interlocking nail systems (C-Nail; Medin, Nov. Město n. Moravě, Czech Republic; Calcanail; FH Orthopedics SAS; Heimsbrunn, France) as well as a polyaxial interlocking plate (Rimbus; Intercus GmbH; Rudolstadt, Germany) were used. Biomechanical testing consisted of a dynamic load sequence (preload 20 N, 1000 N up to 2500 N, stepwise increase of 100 N every 100 cycles, 0.5 mm/s) and a load to failure sequence (max. load 5000 N, 0.5 mm/s). Interfragmentary movement was detected via a 3-D optical measurement system. Boehler angle was measured after osteosynthesis and after failure occurred. No significant difference regarding load to failure, stiffness, Boehler angle, or interfragmentary motion was found between the different fixation systems. A significant difference was found with the dynamic failure testing sequence where 87.5% of the Calcanail implants failed in contrast to 14% of the C-Nail group (P < .01) and 66% of the Rimbus plate. The highest load to failure was observed for the C-Nail. Boehler angle showed physiologic range with all implants before and after the biomechanical tests. Both minimally invasive interlocking nail systems displayed a high primary stability that was not inferior to an interlocking plate. Based on our results, both interlocking nails appear to represent a viable option for treating displaced intra-articular calcaneal fractures. © The Author(s) 2016.

  5. Introduction of a New Locking Nail for Treatment of Intraarticular Calcaneal Fractures.

    PubMed

    Zwipp, Hans; Paša, Libor; Žilka, Luboš; Amlang, Michael; Rammelt, Stefan; Pompach, Martin

    2016-03-01

    To reduce the complication rate associated with open reduction and internal fixation of displaced intraarticular calcaneal fractures through extensile approaches, a locking nail system (C-Nail) was developed for internal fixation. Prospective case-control study. Two level I trauma centers (university hospital) and 1 large regional hospital in the Czech Republic and Germany. One hundred three patients (89 male and 14 female; mean age, 45.6 years) with 106 calcaneal fractures were treated between February 2011 and October 2013. In all 106 cases, the stainless steel C-Nail with a length of 65 mm, a diameter of 8 mm, and 7 locking options was used for internal fixation. Previous reduction of the posterior facet was performed in 15 cases percutaneously, assisted by arthroscopy and fluoroscopy, and in 91 cases by a sinus tarsi approach. The reduced joint surface was fixed by 1 or 2 compression screws. All other fragments were fixed after reduction and temporary K-wire fixation with the C-Nail introduced percutaneously through the tuberosity and 5 to 6 interlocking screws. The latter were introduced into the sustentacular, the tuberosity, and the anterior process fragments with an aiming device consisting of 3 arms. Patients were assessed for complications, restoration of Böhler angle, posterior facet reduction with postoperative computed tomography, and weight-bearing radiographs at 6 months. Functional outcome was assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) ankle/hindfoot scale after 6 and 12 months for all patients. Wound edge necrosis was seen in 2 cases (1.9%), and soft tissue infection was observed in 1 case (0.9%). Böhler angle improved from 7.3 degree preoperatively to 28.7 degree at 6 months. The posterior facet step-off was reduced from 5.3 mm preoperatively to 0.7 mm postoperatively. The average AOFAS score averaged 89.5 at 6-month and 92.6 at 12-month follow-up. The C-Nail is a new locking system for treatment of displaced intraarticular calcaneal fractures combining a primary stability with reduced soft tissue complications. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  6. Impact Damage and Strain Rate Effects for Toughened Epoxy Composite Structures

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.; Minnetyan, Levon

    2006-01-01

    Structural integrity of composite systems under dynamic impact loading is investigated herein. The GENOA virtual testing software environment is used to implement the effects of dynamic loading on fracture progression and damage tolerance. Combinations of graphite and glass fibers with a toughened epoxy matrix are investigated. The effect of a ceramic coating for the absorption of impact energy is also included. Impact and post impact simulations include verification and prediction of (1) Load and Impact Energy, (2) Impact Damage Size, (3) Maximum Impact Peak Load, (4) Residual Strength, (5) Maximum Displacement, (6) Contribution of Failure Modes to Failure Mechanisms, (7) Prediction of Impact Load Versus Time, and (8) Damage, and Fracture Pattern. A computer model is utilized for the assessment of structural response, progressive fracture, and defect/damage tolerance characteristics. Results show the damage progression sequence and the changes in the structural response characteristics due to dynamic impact. The fundamental premise of computational simulation is that the complete evaluation of composite fracture requires an assessment of ply and subply level damage/fracture processes as the structure is subjected to loads. Simulation results for the graphite/epoxy composite were compared with the impact and tension failure test data, correlation and verification was obtained that included: (1) impact energy, (2) damage size, (3) maximum impact peak load, (4) residual strength, (5) maximum displacement, and (6) failure mechanisms of the composite structure.

  7. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    PubMed Central

    Ozan, Fırat; Koyuncu, Şemmi; Pekedis, Mahmut; Altay, Taşkın; Yıldız, Hasan; Toker, Gökhan

    2014-01-01

    The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women) was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA). Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%). Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%). FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery. PMID:25177703

  8. Deformation twinning in irradiated ferritic/martensitic steels

    NASA Astrophysics Data System (ADS)

    Wang, K.; Dai, Y.; Spätig, P.

    2018-04-01

    Two different ferritic/martensitic steels were tensile tested to gain insight into the mechanisms of embrittlement induced by the combined effects of displacement damage and helium after proton/neutron irradiation in SINQ, the Swiss spallation neutron source. The irradiation conditions were in the range: 15.8-19.8 dpa (displacement per atom) with 1370-1750 appm He at 245-300 °C. All the samples fractured in brittle mode with intergranular or cleavage fracture surfaces when tested at room temperature (RT) or 300 °C. After tensile test, transmission electron microscopy (TEM) was employed to investigate the deformation microstructures. TEM-lamella samples were extracted directly below the intergranular fracture surfaces or cleavage surfaces by using the focused ion beam technique. Deformation twinning was observed in irradiated specimens at high irradiation dose. Only twins with {112} plane were observed in all of the samples. The average thickness of twins is about 40 nm. Twins initiated at the fracture surface, became gradually thinner with distance away from the fracture surface and finally stopped in the matrix. Novel features such as twin-precipitate interactions, twin-grain boundary and/or twin-lath boundary interactions were observed. Twinning bands were seen to be arrested by grain boundaries or large precipitates, but could penetrate martensitic lath boundaries. Unlike the case of defect free channels, small defect-clusters, dislocation loops and dense small helium bubbles were observed inside twins.

  9. Facilitation of bone resorption activities in synovial lavage fluid patients with mandibular condyle fractures.

    PubMed

    Takano, H; Takahashi, T; Nakata, A; Nogami, S; Yusa, K; Kuwajima, S; Yamazaki, M; Fukuda, M

    2016-05-01

    The aim of this study was to investigate the bone resorption effect of the mediators delivered in joint cavity of patients with mandibular condyle fractures by detecting osteoclast markers using cellular biochemistry methods, and by analysing bone resorption activities via inducing osteoclast differentiation of the infiltrated cells from arthrocentesis. Sixteen joints in 10 patients with mandibular condyle fractures were evaluated. The control group consisted of synovial fluid (SF) samples from seven joints of four volunteers who had no clinical signs or symptoms involving the temporomandibular joint (TMJ) or disc displacement. We collected SF cells from all patients during therapeutic arthrocentesis. The infiltrating cells from TMJ SF were cultured, differentiated into tartrate-resistant acid phosphatase (TRAP)-positive osteoclast-like cells and examined bone resorption activities. We also investigated factors related to osteoclast induction of SF, using ELISA procedures. Osteoclast-like cells were induced from the SF cells obtained from all patients with condylar fractures. These multinucleated giant cells were positive for TRAP and actin, and had the ability to absorb dentin slices. The levels of macrophage colony-stimulating factor (M-CSF), prostaglandin E2 (PGE2), soluble form of receptor activator of nuclear factor kappa-B ligand (sRANKL) and osteoprotegerin (OPG), in SF samples from the patients, were significantly higher than in the controls. These findings indicate that bone resorption activities in SF from patients with mandibular condyle fractures were upregulated and may participate in the pathogenesis and wound healing. © 2016 The Authors. Journal of Oral Rehabilitation Published by John Wiley & Sons Ltd.

  10. Steam injection pilot study in a contaminated fractured limestone (Maine, USA): Modeling and analysis of borehole radar reflection data

    USGS Publications Warehouse

    Gregoire, C.; Lane, J.W.; Joesten, P.K.

    2005-01-01

    Steam-enhanced remediation (SER) has been successfully used to remove DNAPL and LNAPL contaminants in porous media. Between August and November 2002, SER was tested in fractured limestone at the former Loring Air Force Base, in Maine, USA. During the SER investigation, the U.S. Geological Survey conducted a series of borehole radar surveys to evaluate the effectiveness of radar methods for monitoring the movement of steam and heat through the fractured limestone. The data were collected before steam injection, 10 days after the beginning of injection, and at the end of injection. In this paper, reflection-mode borehole radar data from wells JBW-7816 and JBW-7817A are presented and discussed. Theoretical modeling was performed to predict the variation of fracture reflectivity owed to heating, to show displacement of water and to assess the effect of SER at the site. Analysis of the radar profile data indicates some variations resulting from heating (increase of continuity of reflectors, attenuation of deeper reflections) but no substantial variation of traveltimes. Spectral content analysis of several individual reflections surrounding the boreholes was used to investigate the replacement of water by steam in the fractures. Observed decrease in radar reflectivity was too small to be explained by a replacement of water by steam, except for two high-amplitude reflectors, which disappeared near the end of the injection; moreover, no change of polarity, consistent with steam replacing water, was observed. The decrease of amplitude was greater for reflectors near well JBW-7817A and is explained by a greater heating around this well.

  11. Gradual Reduction of Chronic Fracture Dislocation of the Ankle Using Ilizarov/Taylor Spatial Frame

    PubMed Central

    Deland, Jonathan T.; Rozbruch, S. Robert

    2010-01-01

    With the advances in trauma care, chronic fracture dislocation of the ankle is not a condition commonly seen in modern clinical practice. When encountered, it can be difficult to preserve the ankle joint. We present a case of a 65-year-old female, with a chronic fracture dislocation of the ankle. The ankle joint was subluxated with posterior translation of the talus, displacement of the posterior malleolus fragment, and a distal fibula fracture. A minimally traumatic approach was devised to treat this complex fracture dislocation which included gradual reduction of the ankle with a Taylor spatial frame, followed by stabilization with internal fixation and removal of the frame. Bony union and restoration of the ankle joint congruency was achieved. PMID:22294963

  12. Smoothing and roughening of slip surfaces in direct shear experiments

    NASA Astrophysics Data System (ADS)

    Sagy, Amir; Badt, Nir; Hatzor, Yossef H.

    2015-04-01

    Faults in the upper crust contain discrete slip surfaces which have absorbed a significant part of the shear displacement along them. Field measurements demonstrate that these surfaces are rough at all measurable scales and indicate that surfaces of relatively large-slip faults are statistically smoother than those of small-slip faults. However, post faulting and surface erosion process that might affect the geometry of outcrops cannot be discounted in such measurements. Here we present experimental results for the evolution of shear surface topography as function of slip distance and normal stress in direct shear experiments. A single prismatic fine grain limestone block is first fractured in tension mode using the four-point bending test methodology and then the fracture surface topography is scanned using a laser profilometer. We then shear the obtained tensile fracture surfaces in direct shear, ensuring the original fracture surfaces are in a perfectly matching configuration at the beginning of the shear test. First, shearing is conducted to distances varying from 5 to 15 mm under constant normal stress of 2MPa and a constant displacement rate of 0.05 mm/s using two closed-loop servo controlled hydraulic pistons, supplying normal and shear forces (Davidesko et al., 2014). In the tested configuration peak shear stress is typically attained after a shear displacement of about 2-3 mm, beyond which lower shear stress is required to continue shearing at the preset displacement rate of 0.05 mm/s as is typical for initially rough joints. Following some initial compression the interface begins to dilate and continues to do so until the end of the test. The sheared tensile fracture surface is then scanned again and the geometrical evolution, in term of RMS roughness and power spectral density (PSD) is analyzed. We show that shearing smooth the surface along all our measurements scales. The roughness ratio, measured by initial PSD / final PSD for each wavelength, increases as a function of slip amount. The roughness measured after slip can be fitted by a power-law similar to that of the initial tensile surface. In the next series of experiments a similar procedure is applied when the roughness evolution is measured as a function of increasing normal stress for a fixed displacement amount of 10 mm. While samples sheared under a constant normal stress of 5 MPa generated surface smoothing, shearing under normal stress of 7.5 MPa to 15 MPa exhibited surface roughening at the measured range of scales. We find that roughening is correlated with the attained peak shear stress values, stress drop (peak shear stress minus residual shear stress) and with wear accumulation, a novel measurement procedure of which is developed here. Analysis of the sheared samples shows that roughening is generated by sets of dense fractures that significantly damaged the sample in the immediate proximity to large asperities. This roughening is related to penetrative damage during transient wear in rough surfaces.

  13. Open reduction and internal fixation of mandibular fracture in an 11-month-old infant: a case report

    PubMed Central

    Kim, Tae-Wan; Seo, Eun-Woo

    2013-01-01

    Mandibular fractures in infants are rare. This case report describes management of a mandibular fracture in an 11-month-old infant using a microplate and screws with open reduction. The surgical treatment was successful. Because the bone fragments were displaced and only the primary incisors had erupted, conservative treatment, such as an acrylic splint and circummandibular wiring, was not recommended. Nine weeks after surgery, the microplate was removed. The results showed complete clinical and radiological bone healing with normal eruption of deciduous teeth. PMID:24471024

  14. How much articular displacement can be detected using fluoroscopy for tibial plateau fractures?

    PubMed

    Haller, Justin M; O'Toole, Robert; Graves, Matthew; Barei, David; Gardner, Michael; Kubiak, Erik; Nascone, Jason; Nork, Sean; Presson, Angela P; Higgins, Thomas F

    2015-11-01

    While there is conflicting evidence regarding the importance of anatomic reduction for tibial plateau fractures, there are currently no studies that analyse our ability to grade reduction based on fluoroscopic imaging. The purpose of this study was to determine the accuracy of fluoroscopy in judging tibial plateau articular reduction. Ten embalmed human cadavers were selected. The lateral plateau was sagitally sectioned, and the joint was reduced under direct visualization. Lateral, anterior-posterior (AP), and joint line fluoroscopic views were obtained. The same fluoroscopic views were obtained with 2mm displacement and 5mm displacement. The images were randomised, and eight orthopaedic traumatologists were asked whether the plateau was reduced. Within each pair of conditions (view and displacement from 0mm to 5mm) sensitivity, specificity, and intraclass correlations (ICC) were evaluated. The AP-lateral view with 5mm displacement yielded the highest accuracy for detecting reduction at 90% (95% CI: 83-94%). For the other conditions, accuracy ranged from (37-83%). Sensitivity was highest for the reduced lateral view (79%, 95% CI: 57-91%). Specificity was highest in the AP-lateral view 98% (95% CI: 93-99%) for 5mm step-off. ICC was perfect for the AP-lateral view with 5mm displacement, but otherwise agreement ranged from poor to moderate at ICC=0.09-0.46. Finally, there was no additional benefit to including the joint-line view with the AP and lateral views. Using both AP and lateral views for 5mm displacement had the highest accuracy, specificity, and ICC. Outside of this scenario, agreement was poor to moderate and accuracy was low. Applying this clinically, direct visualization of the articular surface may be necessary to ensure malreduction less than 5mm. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    PubMed

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  16. Modified preauricular approach and rigid internal fixation for intracapsular condyle fracture of the mandible.

    PubMed

    He, Dongmei; Yang, Chi; Chen, Minjie; Bin, Jiang; Zhang, Xiaohu; Qiu, Yating

    2010-07-01

    This article reports a modified preauricular approach for intracapsular condyle fracture (ICF) of the mandible and evaluates the stability of various internal fixation methods in the temporomandibular joint (TMJ) division of the Shanghai Ninth People's Hospital. One hundred fifty-one patients with 208 ICFs diagnosed by panoramic radiograph and computed tomographic (CT) scan received open treatment in the TMJ division from 1999 to 2008. Their charts were reviewed. Classification of the fracture was based on coronal CT scan. Forty-three patients also underwent magnetic resonance imaging before the operation to check displacement of the disc. A modified preauricular approach was used for all patients. Various internal fixation methods from wire, to screw, to plate were evaluated for stability. There were 110 ICFs of type A fracture, 60 of type B fracture, 9 of type C fracture, 25 of type M fracture, and 4 fractures without displacement. A modified preauricular approach was used for open treatment, which can better expose and protect the TMJ and superficial temporal vessels. Wire and plate is the commonly used stable fixation method for type A, B, and M fractures, which accounted for 56.7% (101/178). Small fracture fragments were removed with disc repositioning for all type C fractures (n = 9) and some type B (n = 9) and M fractures (n = 5). Three type M fracture and 3 nondisplaced ICFs were treated closed. Eighty-nine patients with 115 ICFs had postoperative CT scan, which showed anatomic and nearly anatomic fracture reduction rates of 95.6%. Thirty-five patients with 44 ICFs had long-term follow-ups from 3 months to 5 years. Among them, 63.2% (n = 12/19) pediatric ICFs had continuous condyle growth after open reduction and rigid fixation; 92% adults had ICFs that healed well (n = 23/25). Postoperative complications were facial nerve injury (n = 3), TMJ clicking (n = 1), and condyle resorption that required plate removal (n = 4). A modified preauricular approach provides better exposure and protection of the TMJ and superficial temporal vessels. Wire and plate provides stable fixation for type A and some type B and M fractures. Open reduction and rigid fixation produce good results for adult patients. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Stress-dependent permeability and ground displacement during CO2 storage operation at KB-502 injection well, In Salah, Algeria

    NASA Astrophysics Data System (ADS)

    Rinaldi, A.; Rutqvist, J.

    2012-12-01

    The In Salah CO2 storage project (a joint venture among Statoil, BP, and Sonatrach) is one of the most important sites for understanding the geomechanics associated with carbon dioxide injection. InSAR data evaluated for the first years of injection show a ground-surface uplift of 5 to 10 mm per year at each of the injection wells. A double-lobe uplift pattern has been observed at KB-502, and both semi-analytical inverse deformation analysis (Vasco et al., 2010) and coupled numerical modeling of fluid flow and geomechanics (Rutqvist et al., 2011) have shown that this pattern of displacement can be explained by injection-induced deformation in a deep vertical fracture zone of fault, whose presence has been confirmed by recent 3D seismic survey (Gibson-Poole et al., 2010). Recently, Rinaldi and Rutqvist (2012) refined the previous modeling results, through the use of TOUGH-FLAC (Rutqvist et al., 2002), in order to more conclusively constrain the height of the fracture zone. Results were well in agreement with all available field observations, including all time evolutions and the shape of surface deformation, time-evolution of injection pressure, and the 3D seismic indications of the CO2 saturated fracture zone extending thousands of meters laterally. However, the analysis included a number of simplifications and uncertainties, such as time-step changes in aquifer permeability and the use of an elastic model, which preclude a good match with field data after shut in. Here we implement a new stress-dependent permeability function, to consider a more realistic changes in reservoir and fracture zone permeability, and to improve the match between field observations and modeling results, considering both the bottomhole pressure and the ground surface displacement. Furthermore, here we extent the length of the simulation to include modeling of the re-injection occurred in late 2010 for few months. A second major simplification by Rinaldi and Rutqvist (2012) is the assumption of fracture zone that could have opened instantaneously. Here we present also some early, simple study on potential fracture propagations coupled with stress-dependent permeability changes.

  18. Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures.

    PubMed

    Zheng, Yin-Feng; Zhou, Jun-Lin; Wang, Xiao-Hong; Shan, Lei; Liu, Yang

    2016-08-05

    Open reduction and internal fixation with plate and screws are the gold standard for the surgical treatment of humeral shaft fractures, this study was to compare the mechanical properties of anteromedial, anterolateral, and posterior plating for humeral shaft fractures. A distal third humeral shaft fracture model was constructed using fourth-generation sawbones (#3404, composite bone). A total of 24 sawbones with a distal third humeral shaft fracture was randomly divided into three Groups: A, B, and C (n = 8 in each group) for anteromedial, anterolateral, and posterior plating, respectively. All sawbones were subjected to horizontal torsional fatigue tests, horizontal torsional and axial compressive fatigue tests, four-point bending fatigue tests in anteroposterior (AP) and mediolateral (ML) directions and horizontal torsional destructive tests. In the horizontal torsional fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 6.12°, 6.53°, and 6.81°. In horizontal torsional and axial compressive fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 5.66°, 5.67°, and 6.36°. The mean plate displacement amplitude was 0.05 mm, 0.08 mm, and 0.10 mm. Group A was smaller than Group C (P < 0.05). In AP four-point bending fatigue tests, the mean plate displacement amplitude was 0.16 mm, 0.13 mm, and 0.20 mm. Group B was smaller than Group C (P < 0.05). In ML four-point bending fatigue tests, the mean plate displacement amplitude were 0.16 mm, 0.19 mm, and 0.17 mm. In horizontal torsional destructive tests, the mean torsional rigidity in Groups A, B, and C was 0.82, 0.75, and 0.76 N·m/deg. The yielding torsional angle was 24.50°, 25.70°, and 23.86°. The mean yielding torque was 18.46, 18.05, and 16.83 N·m, respectively. Anteromedial plating was superior to anterolateral or posterior plating in all mechanical tests except in AP four-point bending fatigue tests compared to the anterolateral plating group. We can suggest that anteromedial plating is a clinically safe and effective way for humeral shaft fractures.

  19. External fixation for displaced intra-articular fractures of the calcaneum.

    PubMed

    Magnan, B; Bortolazzi, R; Marangon, A; Marino, M; Dall'Oca, C; Bartolozzi, P

    2006-11-01

    A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders' type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler's angle was 6.98 degrees (5.95 degrees to 19.86 degrees), whereas after surgery the mean value was 21.94 degrees (12.58 degrees to 31.30 degrees) (p < 0.01). Excellent results on CT scanning were demonstrated in 24 cases (44.4%), good in 25 (46.3%), fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique.

  20. [Biomechanical analysis on healing process of sagittal fracture of the mandibular condyle after rigid fixation].

    PubMed

    Jing, Jie; Qu, Ai-li; Ding, Xiao-mei; Hei, Yu-na

    2015-04-01

    To analyze the biomechanical healing process on rigid fixation of sagittal fracture of the mandibular condyle (SFMC), and to provide guidelines for surgical treatment. Three-dimensional finite element model (3D-FEAM) of mandible and condyle was established. The right condyle was simulated as SFMC with 0.1 mm space across the condyle length ways. The 3D-FEAM of rigid fixation was established. The biomechanical factors such as stress distribution of condylar surface, displacement around fracture, stress on the plate and stress shielding were calculated during 0, 4, 8 and 12-week after rigid fixation. The maximum equivalent stress of normal condyle was located at the area of middle 1/3 of condylar neck. The maximum equivalent stress at 0-week after fixation was 23 times than that on normal condyle. They were located at the condylar stump and the plate near inferior punctual areas of fracture line. There were little stress on the other areas. The maximum equivalent stress at 4, 8 and 12-week was approximately 6 times than that on normal condyle. They were located at the areas same as the area at 0-week. There were little stress on the other areas at the condyle. The maximum total displacement and maximum total corner were increased 0.57-0.75 mm and 0.01-0.09° respectively during healing process. The maximum equivalent stress at 0-week on the condylar trump was 5-6 times compared with that at 4, 8, and 12-week. The maximum equivalent stress, maximum total displacement and maximum total corner on the fractured fragment were not changed significantly during healing process. The maximum equivalent stress at 0-week on the plate was 7-9 times compared with that at 4, 8, 12-week. The stress of the condyle and stress shielding of the plate may be the reasons of absorbing and rebuilding on the condyle in healing process of SFMC. The biomechanical parameters increase obviously at 4-week after fixation. Elastic intermaxillary traction is necessary to decrease total displacement and total corner of the condyle, and liquid diet is necessary to decrease equivalent stress within 4 weeks. Rehabilitation training should be used to recover TMJ functions after 4 weeks because the condyle and mandible have the ability to carry out normal functions.

  1. [Patella fractures in knee arthroplasty].

    PubMed

    Roth, A; Ghanem, M; Fakler, J

    2016-05-01

    Periprosthetic patella fractures occur both with and without retropatellar joint replacement. A non-operative treatment yields satisfactory results with low morbidity. It can be applied in minimally displaced fractures that have an intact retropatellar component and an intact extensor mechanism, combined with an initial immobilization. The surgical treatment is associated with relatively poor results and with high complication rates. There was only minor improvement of functional results, no matter which surgical technique was used. Surgical intervention is still required in fractures with a loosening of the patellar component, considerable dislocations of fragments, and damage to or rupture of the extensor mechanism. In particular, type II fractures require repair of the extensor mechanism and the fracture or patellectomy. Type III fractures require a revision or resection of the patella, a patelloplasty or total patellectomy. In addition, early or late reconstruction using allograft to restore the extensor mechanism can be taken in consideration.

  2. Hydraulic fracture height limits and fault interactions in tight oil and gas formations

    NASA Astrophysics Data System (ADS)

    Flewelling, Samuel A.; Tymchak, Matthew P.; Warpinski, Norm

    2013-07-01

    widespread use of hydraulic fracturing (HF) has raised concerns about potential upward migration of HF fluid and brine via induced fractures and faults. We developed a relationship that predicts maximum fracture height as a function of HF fluid volume. These predictions generally bound the vertical extent of microseismicity from over 12,000 HF stimulations across North America. All microseismic events were less than 600 m above well perforations, although most were much closer. Areas of shear displacement (including faults) estimated from microseismic data were comparatively small (radii on the order of 10 m or less). These findings suggest that fracture heights are limited by HF fluid volume regardless of whether the fluid interacts with faults. Direct hydraulic communication between tight formations and shallow groundwater via induced fractures and faults is not a realistic expectation based on the limitations on fracture height growth and potential fault slip.

  3. Controls on fault zone structure and brittle fracturing in the foliated hanging wall of the Alpine Fault

    NASA Astrophysics Data System (ADS)

    Williams, Jack N.; Toy, Virginia G.; Massiot, Cécile; McNamara, David D.; Smith, Steven A. F.; Mills, Steven

    2018-04-01

    Three datasets are used to quantify fracture density, orientation, and fill in the foliated hanging wall of the Alpine Fault: (1) X-ray computed tomography (CT) images of drill core collected within 25 m of its principal slip zones (PSZs) during the first phase of the Deep Fault Drilling Project that were reoriented with respect to borehole televiewer images, (2) field measurements from creek sections up to 500 m from the PSZs, and (3) CT images of oriented drill core collected during the Amethyst Hydro Project at distances of ˜ 0.7-2 km from the PSZs. Results show that within 160 m of the PSZs in foliated cataclasites and ultramylonites, gouge-filled fractures exhibit a wide range of orientations. At these distances, fractures are interpreted to have formed at relatively high confining pressures and/or in rocks that had a weak mechanical anisotropy. Conversely, at distances greater than 160 m from the PSZs, fractures are typically open and subparallel to the mylonitic or schistose foliation, implying that fracturing occurred at low confining pressures and/or in rocks that were mechanically anisotropic. Fracture density is similar across the ˜ 500 m width of the field transects. By combining our datasets with measurements of permeability and seismic velocity around the Alpine Fault, we further develop the hierarchical model for hanging-wall damage structure that was proposed by Townend et al. (2017). The wider zone of foliation-parallel fractures represents an outer damage zone that forms at shallow depths. The distinct < 160 m wide interval of widely oriented gouge-filled fractures constitutes an inner damage zone. This zone is interpreted to extend towards the base of the seismogenic crust given that its width is comparable to (1) the Alpine Fault low-velocity zone detected by fault zone guided waves and (2) damage zones reported from other exhumed large-displacement faults. In summary, a narrow zone of fracturing at the base of the Alpine Fault's hanging-wall seismogenic crust is anticipated to widen at shallow depths, which is consistent with fault zone flower structure models.

  4. Residual Strength Analyses of Monolithic Structures

    NASA Technical Reports Server (NTRS)

    Forth, Scott (Technical Monitor); Ambur, Damodar R. (Technical Monitor); Seshadri, B. R.; Tiwari, S. N.

    2003-01-01

    Finite-element fracture simulation methodology predicts the residual strength of damaged aircraft structures. The methodology uses the critical crack-tip-opening-angle (CTOA) fracture criterion to characterize the fracture behavior of the material. The CTOA fracture criterion assumes that stable crack growth occurs when the crack-tip angle reaches a constant critical value. The use of the CTOA criterion requires an elastic- plastic, finite-element analysis. The critical CTOA value is determined by simulating fracture behavior in laboratory specimens, such as a compact specimen, to obtain the angle that best fits the observed test behavior. The critical CTOA value appears to be independent of loading, crack length, and in-plane dimensions. However, it is a function of material thickness and local crack-front constraint. Modeling the local constraint requires either a three-dimensional analysis or a two-dimensional analysis with an approximation to account for the constraint effects. In recent times as the aircraft industry is leaning towards monolithic structures with the intention of reducing part count and manufacturing cost, there has been a consistent effort at NASA Langley to extend critical CTOA based numerical methodology in the analysis of integrally-stiffened panels.In this regard, a series of fracture tests were conducted on both flat and curved aluminum alloy integrally-stiffened panels. These flat panels were subjected to uniaxial tension and during the test, applied load-crack extension, out-of-plane displacements and local deformations around the crack tip region were measured. Compact and middle-crack tension specimens were tested to determine the critical angle (wc) using three-dimensional code (ZIP3D) and the plane-strain core height (hJ using two-dimensional code (STAGS). These values were then used in the STAGS analysis to predict the fracture behavior of the integrally-stiffened panels. The analyses modeled stable tearing, buckling, and crack branching at the integral stiffener using different values of critical CTOA for different material thicknesses and orientation. Comparisons were made between measured and predicted load-crack extension, out-of-plane displacements and local deformations around the crack tip region. Simultaneously, three-dimensional capabilities to model crack branching and to monitor stable crack growth of multiple cracks in a large thick integrally-stiffened flat panels were implemented in three-dimensional finite element code (ZIP3D) and tested by analyzing the integrally-stiffened panels tested at Alcoa. The residual strength of the panels predicted from STAGS and ZP3D code compared very well with experimental data. In recent times, STAGS software has been updated with new features and now one can have combinations of solid and shell elements in the residual strength analysis of integrally-stiffened panels.

  5. Acetabular fractures in the elderly treated with a primary Burch-Schneider reinforcement ring, autologous bone graft, and a total hip arthroplasty: a prospective study with a 4-year follow-up.

    PubMed

    Enocson, Anders; Blomfeldt, Richard

    2014-06-01

    To investigate the clinical and radiologic outcomes in elderly patients suffering from an acetabular fracture operated with an acute primary acetabular reinforcement ring, autologous bone graft, and a total hip arthroplasty (THA). Prospective cohort study. Tertiary care university hospital. Fifteen elderly patients (7 women) with a mean age of 76 years and a displaced acetabular fracture after a low-energy trauma were included. The fractures involved the anterior column, but no patients with associated both column fractures were included. All the patients were able to walk independently before the fracture occurred. Primary operation with a Burch-Schneider reinforcement ring, autologous bone graft, and a THA. The patients were reviewed at 4, 12, 24, and 48 months after the fracture occurred. The outcome assessments included complications, reoperations, activity of daily living function, functional scores (Harris hip score and short musculoskeletal function assessment), health-related quality of life [EuroQol (EQ-5D) index score], and radiologic evaluation. There were no prosthetic dislocations, periprosthetic fractures, deep infections, or other adverse events. There were no radiologic signs of loosening of the reinforcement ring or the prosthesis components at any of the follow up sessions, and the autologous bone graft was well incorporated in all the patients at the final follow-up. At 48 months, the mean Harris hip score was 88, the mean short musculoskeletal function assessment dysfunction score was 30, the bother score was 25, and the mean EQ-5D index score was 0.65. All the patients were able to walk independently at the final follow-up. Treatment of displaced anterior column, anterior column posterior hemitransverse and transverse acetabular fractures in elderly patients using a primary reinforcement ring, autologous bone graft, and a THA seems to be a safe option with good functional and radiologic outcomes. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  6. [Distal radius fractures--retrospective quality control after conservative and operative therapy].

    PubMed

    Sommer, C; Brendebach, L; Meier, R; Leutenegger, A

    2001-01-01

    The distal radius fracture is the most frequent fracture in the adult patient. The wide spectrum of different types of fracture and the coexisting factors make the choice for the optimal treatment difficult. As an interne quality control we retrospectively evaluated all patients with distal radius fractures treated in 1995 at our institution. The study included 69 adult patients with 71 distal radius fractures. After on average 26 months 58 patients with 59 fractures were clinically and radiologically evaluated. The patients were asked to give supplementary information about their follow-up treatment as well as any remaining physical difficulties and limitations in the daily life. All x-rays of the broken radius were carefully analysed and compared with the opposite side. The final results were evaluated according to the "Demerit Point System". Patients were treated with five different therapeutical methods. 76.3% of the patients showed a very good/good final result. In 56.7% of the cases secondary fracture dislocation occurred; the dislocation-rate of fractures treated with percutaneous k-wires was 93.3%! A clear correlation between secondary displacement and final results was found. A main factor for an optimal outcome is the anatomic restoration of length and axis of the distal radius as well as of joint congruency, also moderate angular deformities are well tolerated. Our collective showed an unexpected high rate of secondary displacement, especially in the k-wire group. The reasons for this unsatisfactory event are manifold: too optimistic indication, insufficient follow-up examination in the first four to six weeks, inconsequent change to a more stable fixation method in case of a secondary dislocation. The results of this retrospective evaluation had a major impact on our concept of treatment. The dorso-radial double-plate technique combined with bone graft will be more used in the future especially in younger patients. The new standardised concept is the base of a present prospective study.

  7. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture.

    PubMed

    Knežević, Josip; Kodvanj, Janoš; Čukelj, Fabijan; Pamuković, Frane; Pavić, Arsen

    2017-11-01

    To compare the finite element models of two different composite radius fracture patterns, reduced and stabilised with four different fixed-angle dorsal plates during axial, dorsal and volar loading conditions. Eight different plastic models representing four AO/ASIF type 23-A3 distal radius fractures and four AO/ASIF 23-C2 distal radius fractures were obtained and fixed each with 1 of 4 methods: a standard dorsal non-anatomical fixed angle T-plate (3.5mm Dorsal T-plate, Synthes), anatomical fixed-angle double plates (2.4mm LCP Dorsal Distal Radius, Synthes), anatomical fixed angle T-plate (2.4mm Acu-Loc Dorsal Plate, Acumed) or anatomical variable-angle dorsal T-plate (3.5mm, Dorsal Plate, Zrinski). Composite radius with plate and screws were scanned with a 3D optical scanner and later processed in Abaqus Software to generate the finite element model. All models were axially loaded at 3 points (centrally, volarly and dorsally) with 50 N forces to avoid the appearance of plastic deformations of the models. Total displacements at the end of the bone and the stresses in the bones and plates were determined and compared. Maximal von Mises stress in bone for 3-part fracture models was very similar to that in 2-part fracture models. The biggest difference between models and the largest displacements were seen during volar loading. The stresses in all models were the highest above the fracture gap. The best performance in all parameters tested was with the Zrinski plate and the most modest results were with the Synthes T-plate. There was no significant difference between 2-part (AO/ASIF type 23-A3) and 3-part (AO/ASIF 23-C2) fracture models. Maximal stresses in the plates appeared above the fracture gap; therefore, it is worth considering the development of plates without screw holes above the gap. © 2017 Elsevier Ltd. All rights reserved.

  8. Return to competitive sports after medial epicondyle fractures in adolescent athletes: results of operative and nonoperative treatment.

    PubMed

    Lawrence, J Todd R; Patel, Neeraj M; Macknin, Jonathan; Flynn, John M; Cameron, Danielle; Wolfgruber, Hayley C; Ganley, Theodore J

    2013-05-01

    The optimal treatment of medial epicondyle fractures in pediatric athletes remains unclear. To evaluate the outcomes of operative and nonoperative management of medial epicondyle fractures in young athletes. Case series; Level of evidence, 4. The records of all children with fractures of the medial epicondyle over a 5-year period, with a minimum 2 years of follow-up at a pediatric tertiary referral center, were reviewed. Patients with intra-articular entrapment of the fracture fragment or ulnar nerve entrapment were excluded. Treatment decisions were made primarily based on injury mechanism and elbow laxity or instability. Patients were contacted and asked to complete a modified Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire. Complete data with 2-year follow-up were available for 20 athletes: 6 treated nonoperatively and 14 treated operatively. At the latest follow-up, both groups achieved excellent DASH scores. Half of each cohort required physical therapy, and 6 of 14 patients who received operative treatment reported numbness. All patients were either very or completely satisfied with their treatment. Fourteen patients were overhead athletes (8 treated operatively, 6 nonoperatively). Excellent DASH scores were achieved in both groups, and all overhead athletes were able to return to their sport at the next appropriate level. Seven patients were baseball pitchers and sustained a fracture while throwing (4 treated operatively, 3 nonoperatively). None felt their performance was limited after treatment, and excellent DASH scores were achieved in both groups. These data demonstrate that nonoperative treatment can be successful in young athletes with low-energy medial epicondyle avulsions, a stable elbow, and minimal fracture displacement. Surgical management can be successful in athletes who sustain more significant trauma, who have elbow laxity or instability, or who have significant fracture fragment displacement after a fracture of the medial epicondyle.

  9. Comparing fracture healing disorders and long-term functional outcome of polytrauma patients and patients with an isolated displaced midshaft clavicle fracture.

    PubMed

    Ferree, Steven; Hietbrink, Falco; van der Meijden, Olivier A J; Verleisdonk, Egbert Jan M M; Leenen, Luke P H; Houwert, Roderick M

    2017-01-01

    Although clavicle fractures are a common injury in polytrauma patients, the functional outcome of displaced midshaft clavicle fractures (DMCFs) in this population is unknown. Our hypothesis was that there would be no differences in fracture healing disorders or functional outcome in polytrauma patients with a DMCF compared with patients with an isolated DMCF, regardless of the treatment modality. A retrospective cohort study of patients (treated at our level I trauma center) with a DMCF was performed and a follow-up questionnaire was administered. Polytrauma patients, defined as an Injury Severity Score ≥16, and those with an isolated clavicle fracture were compared. Fracture healing disorders (nonunion and delayed union) and delayed fixation rates were determined. Functional outcome was assessed by the Quick Disability of the Arm, Shoulder, and Hand questionnaire. A total of 152 patients were analyzed, 71 polytrauma patients and 81 patients with an isolated DMCF. Questionnaire response of 121 patients (80%) was available (mean, 53 months; standard deviation, 22 months). No differences were found between polytrauma patients and those with an isolated DMCF with regard to nonunion (7% vs. 5%, respectively), delayed union (4% vs. 4%), and delayed fixation rate (13% vs. 13%). Polytrauma patients had an overall worse functional outcome, regardless of initial nonoperative treatment or delayed operative fixation. Polytrauma patients had a similar nonunion and delayed fixation rate but had an overall worse functional outcome compared with patients with an isolated DMCF. For polytrauma patients, a wait and see approach can be advocated without the risk of decreased upper extremity function after delayed fixation. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Second generation locked plating for complex proximal humerus fractures in very elderly patients.

    PubMed

    Gavaskar, Ashok S; Karthik B, Bhupesh; Tummala, Naveen C; Srinivasan, Parthasarathy; Gopalan, Hitesh

    2016-11-01

    Humeral head sacrificing procedures are more favored in elderly patients with complex proximal humerus fractures because of high incidence of failures and complications with osteosynthesis. The purpose of this study is to assess the outcome of second generation locked plating techniques in 3 and 4 part fractures in active elderly patients >70years with an emphasis on function and complications. 29 patients with displaced 3 and 4 part proximal humerus fractures were treated using the principles of second-generation proximal humerus locked plating. Fixed angle locked plating (PHILOS) using the anterolateral deltoid spilt approach augmented with traction cuff sutures was performed. Minimum of 7 locking head screws including 2 calcar screws were used. In cases with a comminuted medial calcar, an endosteal fibular strut was used. Subchondral metaphyseal bone voids were filled with injectable calcium phosphate cement. Radiological outcome (union, head - shaft angle, tuberosity reduction), functional outcome assessment (Constant and ASES scores) and complications (loss of reduction, nonunion and osteonecrosis) were assessed. The fracture united in 24 of the 26 patients available for follow up at a mean of 27 months (12-40 months). 3 patients developed complications that required arthroplasty (fixation failure in 2 patients and osteonecrosis in 1 patient). Follow up age adjusted Constant (63.1±11.9) and ASES scores (62.58±7.5) showed the extent of functional improvement post surgery. Patients with fractures having a non-comminuted medial calcar and valgus displacement of the humeral head had better functional scores and fewer complications. Osteosynthesis with second generation locked plating techniques provide satisfactory outcome in very elderly patients with complex proximal humerus fractures with minimal complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    PubMed

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  12. Open reduction-internal fixation of a navicular body fracture with dorsal displacement of the first and second cuneiforms: a case report.

    PubMed

    Andersen, Robert C; Neiderer, Katherine; Martin, Billy; Dancho, James

    2013-01-01

    Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. He underwent open reduction internal fixation of the navicular body fracture successfully but failed adequate reduction of the navicular cuneiform joint after ligamentous reconstruction. After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.

  13. DISCUSSION ON SPINAL INJURIES

    PubMed Central

    1928-01-01

    (1).—Varieties of spinal injuries, the three groups of common usage: fractures, dislocations, fracture-dislocations. Shall not refer in detail to fractures of the spinous or transverse processes. (2) Mechanics of injury to vertebræ. Two variables: (1) the nature of the bones; (2) the qualities of the force. Spinal injury usually caused by indirect violence. (3) The different results of injuries applied to the head; may break skull, failing that, the neck. Atlas fracture. Difference in qualities of the force causing atlas fracture and low cervical dislocation. (4) The compound nature of the vertebral body. The two columns, anterior, spongy; posterior, compact. The nature of wedge-compression of the vertebral body. Variations in the shape of the wedge. Reasons. Occur at all levels, including cervical spine. (5) Frequency of injury at different levels of vertebral column. “Localization” of injury. The two places of the graph of injury. The cervical at C. 5. Reason. The thoracic-lumbar peak at T. 12, L. 1 industrial. Is there a third peak at C. 2? (6) The effects of violent flexion of the spine: cervical flexion causes luxation at C. 5 or so. Extension causes fracture of odontoid. Violent flexion and extension therefore cause injury at very different levels. Thoracic region, why is there no “peak” of injury at T.6, 7? Lumbar region. (7) Displacement of fragments. Continuation of violence after the essential injury has been effected. Kümmell's disease, no inflammatory process involved. (8) Injury to the intervertebral discs, essential for displacement. Imperfect rupture a cause for difficulty in reducing luxations. The worst cases those in which it is most easily done, but most of these have cord damage. (9) Spinal injury from minimal violence. Examples of trivial cases, diving, brushing hair and so forth. Vertebral displacement in disease a much more serious thing. (10) Curious stability of many cervical luxations. Reasons. Locking of the inferior zygaphophyses. (11) Injury to nervous elements left principally to other speakers. Cord compression very rare. Immediate and irremediable damage. Root injuries. Falling mortality of modern statistics due to better diagnosis. (12) Primary operation for fractures of spine relegated to oblivion. Rarity of indications for open operation. Reduction the best treatment. ImagesFig. 5Fig. 6 PMID:19986314

  14. Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study.

    PubMed

    Miura, Michiaki; Nakamura, Junichi; Matsuura, Yusuke; Wako, Yasushi; Suzuki, Takane; Hagiwara, Shigeo; Orita, Sumihisa; Inage, Kazuhide; Kawarai, Yuya; Sugano, Masahiko; Nawata, Kento; Ohtori, Seiji

    2017-12-16

    Finite element analysis (FEA) of the proximal femur has been previously validated with large mesh size, but these were insufficient to simulate the model with small implants in recent studies. This study aimed to validate the proximal femoral computed tomography (CT)-based specimen-specific FEA model with smaller mesh size using fresh frozen cadavers. Twenty proximal femora from 10 cadavers (mean age, 87.1 years) were examined. CT was performed on all specimens with a calibration phantom. Nonlinear FEA prediction with stance configuration was performed using Mechanical Finder (mesh,1.5 mm tetrahedral elements; shell thickness, 0.2 mm; Poisson's coefficient, 0.3), in comparison with mechanical testing. Force was applied at a fixed vertical displacement rate, and the magnitude of the applied load and displacement were continuously recorded. The fracture load and stiffness were calculated from force-displacement curve, and the correlation between mechanical testing and FEA prediction was examined. A pilot study with one femur revealed that the equations proposed by Keller for vertebra were the most reproducible for calculating Young's modulus and the yield stress of elements of the proximal femur. There was a good linear correlation between fracture loads of mechanical testing and FEA prediction (R 2 = 0.6187) and between the stiffness of mechanical testing and FEA prediction (R 2 = 0.5499). There was a good linear correlation between fracture load and stiffness (R 2 = 0.6345) in mechanical testing and an excellent correlation between these (R 2 = 0.9240) in FEA prediction. CT-based specimen-specific FEA model of the proximal femur with small element size was validated using fresh frozen cadavers. The equations proposed by Keller for vertebra were found to be the most reproducible for the proximal femur in elderly people.

  15. The long-term outcome of displaced mid-third clavicle fractures on scapular and shoulder function: variations between immediate surgery, delayed surgery, and nonsurgical management.

    PubMed

    George, Daniel M; McKay, Bartholomew P; Jaarsma, Ruurd L

    2015-05-01

    Conservative management for uncomplicated displaced clavicle fractures is common practice. Delay of surgical fixation may result in less favorable outcomes. A retrospective cohort study was conducted of 60 patients with a closed mid-third clavicle fracture that did not meet current operative or nonoperative guidelines; 20 primary (plate fixation <6 weeks), 20 delayed (plate fixation >6 weeks), and 20 matched conservative patients were included. Each patient completed 2 questionnaires, the Disabilities of the Arm, Shoulder, and Hand and the American Shoulder and Elbow Surgeons, as well as visual analog scales for pain, cosmetic satisfaction, and overall satisfaction. In addition, 10 patients from each group underwent clinical review of scapular rotation by the lateral scapular slide test, clinical impingement, range of motion assessment, and radiologic review of clavicle union and length. The American Shoulder and Elbow Surgeons patient self-reported questionnaire demonstrated a median score of 5.5 for the delayed group, 2 for the primary group, and 1 for the conservative group (P = .032). The median Disabilities of the Arm, Shoulder, and Hand score was 7.92 for the delayed group, 3.32 for the primary group, and 1.67 for the conservative group (P = .212). Six patients in the delayed group had scapular malrotation compared with 2 in the primary group and none in the conservative group (P = .008). Flexion and external rotation in 90° abduction were decreased in the conservative group (P = .049 and .041, respectively). We support the conservative management of uncomplicated displaced clavicle fractures but recognize that a lower threshold for early surgery should be considered where optimal shoulder function is required. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating.

    PubMed

    Katthagen, Jan Christoph; Ellwein, Alexander; Lutz, Olga; Voigt, Christine; Lill, Helmut

    2017-04-01

    To investigate the outcomes of proximal humeral fracture (PHF) fixation with a novel carbon-fiber-reinforced (CFR)-PEEK plate and to compare results with outcomes after conventional locked titanium plating. Twenty-one patients (7 male, 14 female) with operative treatment of unilateral displaced PHFs (mean age, 66.8 ± 9.9 years) with a novel CRF-PEEK plate were prospectively enrolled. Patients were followed up clinically (Constant Score, Simple Shoulder Test and Simple Shoulder Value) and radiologically 3 months postoperative and again clinically 12 months postoperative. Implant-related complications were evaluated after 3 and 12 months. Results at 1-year follow-up were compared with results of 21 patients (7 male, 14 female; mean age, 67.4 ± 9.7 years) with conventional titanium locked plating by matched case-control analysis. All functional outcomes improved after CFR-PEEK plating (p < 0.05). Twelve months postoperatively, the mean age- and gender-related Constant Score was 99.8 ± 21.2%. All fractures healed by the 3-month follow-up without evidence of secondary screw perforation, fragment displacement or loss of fixation. There were no significant differences between the functional outcomes of patients with the CF-PEEK plate and patients with locked titanium plating (p > 0.05). Patients with locked titanium plating were significantly more likely to require revision surgery related to articular screw perforations (p = 0.048). Fracture fixation of displaced PHFs with a novel CFR-PEEK plate resulted in good to excellent 1-year functional outcomes which were similar to outcomes of conventional locked titanium plating. The stiffer locked titanium plating was associated with a higher risk of articular screw perforations than the more elastic CFR-PEEK plate.

  17. Surgical plate fixation of multiple rib fractures: a case report.

    PubMed

    Mitev, Konstantin; Neziri, Dashurie; Stoicovski, Emil; Mitrev, Zan

    2018-05-29

    The healthcare system in developing countries is limited; particularly, medical specialties such as emergency and trauma medicine are underdeveloped. Consequently, trauma injuries sustained in traffic accidents result in chronic morbidity more often than similar cases in developed countries. Multiple rib fractures induce significant patient morbidity. Current international guidelines recommend a multidisciplinary, surgery-based treatment approach to achieve optimal clinical benefit. We admitted a 41-year-old Albanian man to our emergency department following a pedestrian-vehicle accident 5 days earlier. He presented with severe upper thoracic pain, chest deformity, dyspnea, tachycardia, subcutaneous emphysema, and hematoma. Chest radiography pointed to hypoventilated lung fields and a minor pleural effusion. Computed tomographic scans indicated displaced fractures of right lateral ribs 5 -11, hyperdensity regions from bone fragments, and pulmonary contusion. The treatment consisted of surgical fixation of ribs 7-10 using titanium reconstruction plates and cortical locking screws. The patient's clinical condition rapidly improved postoperatively. Follow-up at 6 weeks confirmed a full return to preoperative daily activities and a high quality of life. In this case report, we present a novel and promising development in the field of trauma medicine in the Republic of Macedonia. Trauma injuries can be treated via advanced multidisciplinary medical care according to international standards, allowing optimal health recovery.

  18. Multidisciplinary Restoration of Traumatized and Displaced Maxillary Central Incisor by Bent Wire System-A Novel Approach.

    PubMed

    Sasalawad, Shilpa S; Jogani, Vivek; Pai, Suryakanth M; Chour, Rashmi C; Balehosur, Deepti V

    2016-11-01

    Management of traumatic injuries to teeth is a challenge to dental practice, as it occurs when dentists are least prepared for it. The direction and the force of the object or the fall significantly affects the diagnosis, treatment plan and therefore the outcome of the treatment. These traumatic injuries may present with different clinical situations which demand immediate attention and assessment by the clinician. The maxillary central incisor crown fractures are the most common variant of trauma, because of the anterior and protrusive positioning. This case report describes the novel method to produce expansion of the dental arches to correct the post-traumatic displacement of the central incisor along with aesthetic and functional rehabilitation of Ellis Class IV fracture of permanent maxillary central incisor.

  19. Clip gage attachment for frictionless measurement of displacement during high-temperature mechanical testing

    DOEpatents

    Alexander, D.J.

    1994-01-04

    An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature is described. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical. 1 figure.

  20. Hayward Fault rocks: porosity, density, and strength measurements

    USGS Publications Warehouse

    Morrow, C.A.; Lockner, D.A.

    2001-01-01

    Porosity, density and strength measurements were conducted on rock samples collected from the Hayward Fault region in Northern California as part of the Hayward Fault Working Group’s efforts to create a working model of the Hayward Fault. The rocks included in this study were both fine and coarse grained gabbros, altered keratophyre, basalt, sandstone, and serpentinite from various rock formations adjacent to the Hayward Fault. Densities ranged from a low of 2.25 gm/cc (altered keratophyre) to 3.05 gm/cc (fine gabbro), with an average of 2.6 gm/cc, typical of many other rocks. Porosities were generally around 1% or less, with the exception of the sandstone (7.6%) and altered keratophyre (13.5%). Failure and frictional sliding tests were conducted on intact rock cylinders at room temperature under effective pressure conditions of up to 192 MPa, simulating depths of burial to 12 km. Axial shortening of the samples progressed at a rate of 0.1 µm/sec (fine samples) or 0.2 µm/sec (porous samples) for 6 mm of displacement. Velocity stepping tests were then conducted for an additional 2 mm of displacement, for a total of 8 mm. Both peak strength (usually failure strength) and frictional strength, determined at 8 mm of displacement, increased systematically with effective pressure. Coefficients of friction, based on the observed fracture angles, ranged from 0.6 to 0.85, consistent with Byerlee’s Law. Possible secondary influences on the strength of the Hayward rock samples may be surface weathering, or a larger number of pre-existing fractures due to the proximity to the Hayward Fault. All samples showed velocity strengthening, so that the average a-b values were all strongly positive. There was no systematic relation between a-b values and effective pressure. Velocity strengthening behavior is associated with stable sliding (creep), as observed in the shallow portions of the Hayward Fault.

  1. A novel pillar indentation splitting test for measuring fracture toughness of thin ceramic coatings

    DOE PAGES

    Sebastiani, Marco; Johanns, K. E.; Herbert, Erik G.; ...

    2014-05-16

    Fracture toughness is an important material property that plays a role in determining the in-service mechanical performance and adhesion of thin ceramic films. Unfortunately, measuring thin film fracture toughness is affected by influences from the substrate and the large residual stresses that can exist in the films. In this paper, we explore a promising new technique that potentially overcomes these problems based on nanoindentation testing of micro-pillars produced by focused ion beam milling of the films. By making the pillar diameter approximately equal to its length, the residual stress in the pillar’s upper portion is almost fully relaxed, and whenmore » indented with a sharp Berkovich indenter, the pillars fracture by splitting at reproducible loads that are readily quantified by a sudden displacement excursion in the load displacement behavior. Cohesive finite element simulations are used to analyze and develop, for a given material, a simple relation between the critical load at failure, pillar radius, and fracture toughness. The main novel aspect of this work is that neither crack geometries nor crack sizes need to be measured post test. Furthermore, the residual stress can be measured at the same time with toughness, by comparing the indentation results from the stress-free pillars and the as-deposited film. The method is tested on three different hard coatings formed by physical vapor deposition: titanium nitride, chromium nitride, and a CrAlN/Si 3N 4 nanocomposite. Results compare well to independently measured values of fracture toughness for the three brittle films. The technique offers several benefits over existing methods.« less

  2. Rereduction for Redisplacement of Both-Bone Forearm Shaft Fractures in Children.

    PubMed

    Eismann, Emily A; Parikh, Shital N; Jain, Viral V

    2016-06-01

    There is a high rate of redisplacement after closed reduction and cast treatment of displaced both-bone forearm shaft fractures in children. Little evidence is available on the efficacy of rereduction of these redisplaced fractures. This study evaluates the impact of rereduction on radiographic outcomes and compares the cost to surgical stabilization. This retrospective study included 31 children (mean age, 6.3 y; 18 boys) treated with rereduction for redisplacement of a displaced both-bone forearm shaft fracture between 2008 and 2013. Angulation was measured on anteroposterior and lateral radiographs of the radius and ulna at injury, after reduction, at redisplacement, after rereduction, and at fracture union. Average procedure costs for rereduction and surgical stabilization were calculated. Initial reduction decreased apex volar angulation (initially >20 degrees) of both bones to a median of ≤2 degrees. After an average of 15 days (range, 4 to 35 d), apex volar angulation of the radius worsened to 9 degrees, and apex ulnar angulation worsened to >10 degrees for both bones. For every 5 days after initial reduction, apex ulnar angulation of the radius worsened by 4 degrees. Rereduction reduced apex ulnar and volar angulation of both bones to <5 degrees, which was maintained after cast removal. There were no complications. The average procedure cost for rereduction was $2056 compared with $4589 for surgical stabilization with or without implant removal. Rereduction of both-bone forearm shaft fractures after redisplacement following initial closed reduction had satisfactory radiographic outcomes and is a safe, effective, and less expensive option than surgical stabilization. Level IV-therapeutic.

  3. Cortical bone fracture analysis using XFEM - case study.

    PubMed

    Idkaidek, Ashraf; Jasiuk, Iwona

    2017-04-01

    We aim to achieve an accurate simulation of human cortical bone fracture using the extended finite element method within a commercial finite element software abaqus. A two-dimensional unit cell model of cortical bone is built based on a microscopy image of the mid-diaphysis of tibia of a 70-year-old human male donor. Each phase of this model, an interstitial bone, a cement line, and an osteon, are considered linear elastic and isotropic with material properties obtained by nanoindentation, taken from literature. The effect of using fracture analysis methods (cohesive segment approach versus linear elastic fracture mechanics approach), finite element type, and boundary conditions (traction, displacement, and mixed) on cortical bone crack initiation and propagation are studied. In this study cohesive segment damage evolution for a traction separation law based on energy and displacement is used. In addition, effects of the increment size and mesh density on analysis results are investigated. We find that both cohesive segment and linear elastic fracture mechanics approaches within the extended finite element method can effectively simulate cortical bone fracture. Mesh density and simulation increment size can influence analysis results when employing either approach, and using finer mesh and/or smaller increment size does not always provide more accurate results. Both approaches provide close but not identical results, and crack propagation speed is found to be slower when using the cohesive segment approach. Also, using reduced integration elements along with the cohesive segment approach decreases crack propagation speed compared with using full integration elements. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Plate fixation versus intramedullary nailing of completely displaced midshaft fractures of the clavicle: a prospective randomised controlled trial.

    PubMed

    Fuglesang, H F S; Flugsrud, G B; Randsborg, P H; Oord, P; Benth, J Š; Utvåg, S E

    2017-08-01

    This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population. We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score. Plate fixation provided a faster functional recovery during the first six months compared with ESIN, but there was no difference after one year. The duration of surgery was shorter for ESIN (mean 53.4 minutes, 22 to 120) than for plate fixation (mean 69.7 minutes, 35 to 106, p < 0.001). The recovery after ESIN was slower with increasing fracture comminution and with open reduction (p < 0.05). Both methods return the patients to their pre-injury functional levels, but plate fixation has a faster recovery period in comminuted fractures than ESIN. ESIN has a shorter operative time and lower infection and implant rates of failure when using 2.5 mm nails or wider, suggesting that this is the preferred method in mid-shaft fractures with no comminution, whereas plate fixation is the superior method in comminuted fractures. Cite this article: Bone Joint J 2017;99-B:1095-1101. ©2017 The British Editorial Society of Bone & Joint Surgery.

  5. Hydrological deformation signals in karst systems: new evidence from the European Alps

    NASA Astrophysics Data System (ADS)

    Serpelloni, E.; Pintori, F.; Gualandi, A.; Scoccimarro, E.; Cavaliere, A.; Anderlini, L.; Belardinelli, M. E.; Todesco, M.

    2017-12-01

    The influence of rainfall on crustal deformation has been described at local scales, using tilt and strain meters, in several tectonic settings. However, the literature on the spatial extent of rainfall-induced deformation is still scarce. We analyzed 10 years of displacement time-series from 150 continuous GPS stations operating across the broad zone of deformation accommodating the N-S Adria-Eurasia convergence and the E-ward escape of the Eastern Alps toward the Pannonian basin. We applied a blind-source-separation algorithm based on a variational Bayesian Independent Component Analysis method to the de-trended time-series, being able to characterize the temporal and spatial features of several deformation signals. The most important ones are a common mode annual signal, with spatially uniform response in the vertical and horizontal components and a time-variable, non-cyclic, signal characterized by a spatially variable response in the horizontal components, with stations moving (up to 8 mm) in the opposite directions, reversing the sense of movement in time. This implies a succession of extensional/compressional strains, with variable amplitudes through time, oriented normal to rock fractures in karst areas. While seasonal displacements in the vertical component (with an average amplitude of 4 mm over the study area) are satisfactorily reproduced by surface hydrological loading, estimated from global assimilation models, the non seasonal signal is associated with groundwater flow in karst systems, and is mainly influencing the horizontal component. The temporal evolution of this deformation signal is correlated with cumulated precipitation values over periods of 200-300 days. This horizontal deformation can be explained by pressure changes associated with variable water levels within vertical fractures in the vadose zones of karst systems, and the water level changes required to open or close these fractures are consistent with the fluctuations of precipitation and with the dynamics of karst systems.

  6. Evaluation of a Computer-Assisted Dental Diagnostic System by Navy Hospital Corpsmen

    DTIC Science & Technology

    1989-06-23

    hypersensitivity 1 Defective restoration Displace/mobility of tooth, favorable prognosis Displace/mobility of tooth, guarded prognosis 2 Endo / perio ... injury Osseous sequestrum 2 Occlusal trauma _1 Periodontal abscess 3 Periocoronitis/erupting tooth 2 Reversible pulpitis Root fracture Total...Trauma Related Injury 1 1 0 *Tooth, Specific 18 26 17 *Teeth, Generalized 1 1 0 *Gingiva, Specific Area 6 1 1 *Gingiva, Generalized Area 2 2 2 *Oral

  7. Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.

    PubMed

    Wurm, Simone; Augat, Peter; Bühren, Volker

    2015-09-01

    To analyze the mechanical stability of locked plating in comparison with tension-band wiring for the fixation of fractures of the patella. Biomechanical tests were performed on artificial foam patella specimens comparing an angular stable plate and monocortical screws with tension-band wiring. Tests were performed under combined tension and bending until failure simulating physiological loading of the tibia during walking. Tension-band wiring failed at 66% of the failure load of plating (1052 N, P = 0.002) and had 5 times larger fracture gap displacements (P = 0.002). Based on the biomechanical advantages, locked plating of the patella may constitute a reasonable alternative in the treatment of patella fractures.

  8. Effect of nano/micro B4C and SiC particles on fracture properties of aluminum 7075 particulate composites under chevron-notch plane strain fracture toughness test

    NASA Astrophysics Data System (ADS)

    Morovvati, M. R.; Lalehpour, A.; Esmaeilzare, A.

    2016-12-01

    Reinforcing aluminum with SiC and B4C nano/micro particles can lead to a more efficient material in terms of strength and light weight. The influence of adding these particles to an aluminum 7075 matrix is investigated using chevron-notch fracture toughness test method. The reinforcing factors are type, size (micro/nano), and weight percent of the particles. The fracture parameters are maximum load, notch opening displacement, the work up to fracture and chevron notch plane strain fracture toughness. The findings demonstrate that addition of micro and nano size particles improves the fracture properties; however, increasing the weight percent of the particles leads to increase of fracture properties up to a certain level and after that due to agglomeration of the particles, the improvement does not happen for both particle types and size categories. Agglomeration of particles at higher amounts of reinforcing particles results in improper distribution of particles and reduction in mechanical properties.

  9. Establishment of a Uniform Format for Data Reporting of Structural Material Properties for Reliability Analysis

    DTIC Science & Technology

    1994-06-30

    tip Opening Displacement (CTOD) Fracture Toughness Measurement". 48 The method has found application in the elastic-plastic fracture mechanics ( EPFM ...68 6.1 Proposed Material Property Database Format and Hierarchy .............. 68 6.2 Sample Application of the Material Property Database...the E 49.05 sub-committee. The relevant quality indicators applicable to the present program are: source of data, statistical basis of data

  10. Rapid orthodontic extrusion using an interocclusal appliance for the reestablishment of biologic width: a case report.

    PubMed

    Kim, Sung Hyun; Tramontina, Vinicius Augusto; Papalexiou, Vula; Luczyszyn, Sônia Mara; Grassi, Maria Bibiana; de Fatima Scarpim, Maria; Tanaka, Orlando Motohiro

    2011-03-01

    A multidisciplinary treatment of a case of subgingival fracture in a maxillary anterior tooth is presented. This case report describes a simple method involving an interocclusal appliance and an elastic band for rapid orthodontic extrusion to reestablish biologic width. In addition, a simple technique for surgical recontouring following the coronal displacement of the gingival margin prior to restoration of fractured tooth is explained.

  11. Internal fixation of displaced inferior pole of the patella fractures using vertical wiring augmented with Krachow suturing.

    PubMed

    Oh, Hyoung-Keun; Choo, Suk-Kyu; Kim, Ji-Wan; Lee, Mark

    2015-12-01

    We present the surgical technique of separate vertical wiring for displaced inferior pole fractures of the patella combined with Krachow suture and report the surgical outcomes. Between September 2007 to May 2012, 11 consecutive patients (mean age, 54.6 years) with inferior pole fractures of the patella (AO/OTA 34-A1) were retrospectively enrolled in this study. Through longitudinal incision, all patients underwent open reduction and internal fixation by separate vertical wiring combined with Krackow suture. The range of motion, loss of fixation, and Bostman score were primary outcome measures. The union time was 10 weeks after surgery on average (range: 8-12). No patient had nonunion, loss of reduction and wire breakage. There was no case of wound problem and irritation from the implant. At final follow-up, the average range of motion arc was 129.4° (range: 120-140). The mean Bostman score at last follow-up was 29.6 points (range: 28-30) and graded excellent in all cases. Separate vertical wiring combined with Krackow suture for inferior pole fractures of the patella is a useful technique that is easy to perform and can provide stable fixation with excellent results in knee function. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Risk of refracture through unicameral bone cysts of the proximal femur.

    PubMed

    Norman-Taylor, Fabian H; Hashemi-Nejad, Aresh; Gillingham, Bruce L; Stevens, David; Cole, William G

    2002-01-01

    The authors determined the results after traction or traction and hip spica treatment of the initial fractures through unicameral bone cysts of the proximal femur in 20 children. All of the eight displaced fractures healed, but with coxa vara and avascular necrosis in one, coxa vara in a second, and coxa breva in a third. Spontaneous healing of the cyst occurred in three of the eight children; satisfactory healing was achieved and maintained after intralesional corticosteroid injections in four of the eight children. In the remaining child with a displaced fracture, reactivation of the cyst and exercise-related pain, indicative of an incipient refracture, occurred 3 years after initial presentation. All of the 12 undisplaced fractures healed without deformity or avascular necrosis. Intralesional corticosteroids were used in all of the 12 children because none of them showed spontaneous healing of their cysts. Satisfactory radiographic healing was achieved 1 year after presentation in all of the 12 children. However, one or more refractures resulting from reactivation of the cyst occurred in 6 of the 12 children 2 to 5 years after initial presentation. The results of this study indicate that satisfactory radiographic healing needs to be achieved by the end of the first year and needs to be maintained thereafter to prevent refractures.

  13. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle.

    PubMed

    Aquilina, Peter; Chamoli, Uphar; Parr, William C H; Clausen, Philip D; Wroe, Stephen

    2013-06-01

    The most stable pattern of internal fixation for fractures of the mandibular condyle is a matter for ongoing discussion. In this study we investigated the stability of three commonly used patterns of plate fixation, and constructed finite element models of a simulated mandibular condylar fracture. The completed models were heterogeneous in the distribution of bony material properties, contained about 1.2 million elements, and incorporated simulated jaw-adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. This model was considerably larger and more complex than previous finite element models that have been used to analyse the biomechanical behaviour of differing plating techniques. The use of two parallel 2.0 titanium miniplates gave a more stable configuration with lower mean element stresses and displacements over the use of a single miniplate. In addition, a parallel orientation of two miniplates resulted in lower stresses and displacements than did the use of two miniplates in an offset pattern. The use of two parallel titanium plates resulted in a superior biomechanical result as defined by mean element stresses and relative movement between the fractured fragments in these finite element models. Copyright © 2012 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Crack stability in a representative piping system under combined inertial and seismic/dynamic displacement-controlled stresses. Subtask 1.3 final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, P.; Olson, R.; Wilkowski, O.G.

    1997-06-01

    This report presents the results from Subtask 1.3 of the International Piping Integrity Research Group (IPIRG) program. The objective of Subtask 1.3 is to develop data to assess analysis methodologies for characterizing the fracture behavior of circumferentially cracked pipe in a representative piping system under combined inertial and displacement-controlled stresses. A unique experimental facility was designed and constructed. The piping system evaluated is an expansion loop with over 30 meters of 16-inch diameter Schedule 100 pipe. The experimental facility is equipped with special hardware to ensure system boundary conditions could be appropriately modeled. The test matrix involved one uncracked andmore » five cracked dynamic pipe-system experiments. The uncracked experiment was conducted to evaluate piping system damping and natural frequency characteristics. The cracked-pipe experiments evaluated the fracture behavior, pipe system response, and stability characteristics of five different materials. All cracked-pipe experiments were conducted at PWR conditions. Material characterization efforts provided tensile and fracture toughness properties of the different pipe materials at various strain rates and temperatures. Results from all pipe-system experiments and material characterization efforts are presented. Results of fracture mechanics analyses, dynamic finite element stress analyses, and stability analyses are presented and compared with experimental results.« less

  15. [Application of temporomandibular joint dics reduction in the operation of condylar sagittal fracture].

    PubMed

    Wenli, Zeng; Wuchao, Zhou; Jingkun, Zhang; Yisen, Shao; Weihong, Xi

    2017-10-01

    To explore the selection of temporomandibular joint (TMJ) disc reduction and fixation methods in condylar sagittal fracture surgery. A total of 36 patients with condylar fractures were chosen. The follow-up period was more 6 months. All 36 cases of condylar sagittal fracture were fixed with long screw. In the operation, the displaced joint disc was repositioned and fixed. The fixed method included direct suture (22 cases) and anchorage (14 cases). Clinical followups were performed before surgery and 1 month, 3 months, 6 months and 1 year after surgery. Clinicians recorded data related to the Fricton craniomandibular index (CMI) and evaluated the postoperative joint function during followup before surgery and 6 months after surgery. In both groups, function of TMJ significantly improved after surgery. The CMI decreased from 0.213±0.162 and 0.273±0.154 to 0.059±0.072 and 0.064±0.068 (P<0.05), respectively. No statistical difference was observed between the two groups in palpation index (PI), dysfunction index (DI) and CMI (P>0.05) before or after surgery. Both methods could effectively improve the dysfunction of the TMJ caused by trauma. The selection of joint disc reduction and fixation methods is based on the displacement and damage degree of the joint disc.

  16. Influence of medial parapatellar nail insertion on alignment in proximal tibia fractures--special consideration of the fracture level.

    PubMed

    Weninger, Patrick; Tschabitscher, Manfred; Traxler, Hannes; Pfafl, Veronika; Hertz, Harald

    2010-04-01

    Although a lateral starting point for tibial nailing is recommended to avoid valgus misalignment, higher rates of intra-articular damage were described compared with a medial parapatellar approach. The aim of this anatomic study was to evaluate the fracture level allowing for a safe medial nail entry point without misalignment or dislocation of fragments. Thirty-two fresh-frozen cadaver lower extremities were used to create 1-cm osteotomies at four different levels (n = 8) from 2 cm to 8 cm below the tibial tuberosity. Nine-millimeter unreamed solid titanium tibial nails (Connex, I.T.S. Spectromed, Lassnitzhohe, Austria) were inserted from a medial parapatellar incision. Misalignment (degree) and dislocation of the distal fragment were measured in the frontal and sagittal plane. A medial parapatellar approach for tibial nail insertion mainly caused valgus and anterior bow misalignment and ventral and medial fragment displacement. Mean misalignment and fragment displacement did not exceed 0.5 degree if the osteotomy was performed 8 cm to 9 cm below the tibial tuberosity. According to the results of this study, a medial parapatellar approach can be performed without misalignment and fragment dislocation in proximal tibia fractures extending 8 cm or more below the tibial tuberosity.

  17. Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.

    PubMed

    da Frota, Matheus F; Espir, Camila G; Berbert, Fábio L C V; Marques, André A F; Sponchiado-Junior, Emílio C; Tanomaru-Filho, Mario; Garcia, Lucas F R; Bonetti-Filho, Idomeo

    2014-12-01

    As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

  18. Surface faulting near Livermore, California, associated with the January 1980 earthquakes

    USGS Publications Warehouse

    Bonilla, Manuel G.; Lienkaemper, James J.; Tinsley, John C.

    1980-01-01

    The earthquakes of 24 January (Ms 5.8) 1980 north of Livermore, California, and 26 January (Ms 5.2), were accompanied by surface faulting in the Greenville fault zone and apparently in the Las Positas fault zone also. The surface faulting was discontinuous and of small displacement. The main rupture within the Greenville fault zone trended about N.38°W. It was at least 4.2 km long and may have extended southward to Interstate Highway 580, giving a possible length of 6.2 km; both of these lengths included more gaps than observed surface rupture. Maximum displacements measured by us were about 25 mm of right slip (including afterslip through 28 January); vertical components of as much as 50 mm were seen locally, but these included gravity effects of unknown amount. The main break within the Greenville fault zones is very close to a fault strand mapped by Herd (1977, and unpublished data). A subsidiary break within the Greenville fault zone was about 0.5 km. long, had a general trend of N.46°W., and lay 0.12 to 0.25 km east of the main break. It was characterized by extension of as much as 40 mm and right slip of as much as 20 mm. This break was no more than 25 m from a fault mapped by Herd (unpublished data). Another break within the Greenville fault zone lay about 0.3 km southwest of the projection of the main break and trended about N33°W. It was at least 0.3 km long and showed mostly extension, but at several places a right-lateral component (up to 5 mm) was seen. This break was 80 to 100 m from a strand of the Greenville fault mapped by Herd (1977). Extensional fractures within the Greenville fault zone on the frontage roads north and south of Interstate Highway 580 may be related to regional extension or other processes, but do not seem to have resulted from faulting of the usual kind. One exception in this group is a fracture at the east side of Livermore valley which showed progressive increase in right-lateral displacement in February and March, 1980, and is directly on the projection of a fault in the Greenville fault zone mapped by Herd (1977). A group of more than 20 extensional fractures in Laughlin Road 1 km north of Interstate 580 probably are related to small tectonic displacements on faults in the Greenville fault zone. They are adjacent and parallel to two faults mapped by Herd (1977), are diagonal to the road, and most of them developed between 25 and 29 January, a period that included the Ms 5.2 shock of 26 January. Observations at two locations indicate tectonic displacement on the Las Positas fault zone as mapped by Herd (1977). At Vasco Road a prominent break on a strand of the fault showed about 0.5 mm of left-lateral strike slip on 7 February. An alinement array across this and other fractures at the locality indicates about 6 mm of left-lateral displacement occurred between 21 February and 26 March. On Tesla Road several right-stepping fractures, one of which showed 1.5 mm of left-lateral strike slip, lie on or close tp previously mapped strands of the Las Positas fault zone. The evidence at these two localities indicates that tectonic surface displacement occurred along at least 1.1 km of the Las Positas fault zone.

  19. Optimal Post-Operative Immobilisation for Supracondylar Humeral Fractures.

    PubMed

    Azzolin, Lucas; Angelliaume, Audrey; Harper, Luke; Lalioui, Abdelfettah; Delgove, Anaïs; Lefèvre, Yan

    2018-05-25

    Supracondylar humeral fractures (SCHFs) are very common in paediatric patients. In France, percutaneous fixation with two lateral-entry pins is widely used after successful closed reduction. Post-operative immobilisation is typically with a long arm cast combined with a tubular-bandage sling that immobilises the shoulder and holds the arm in adduction and internal rotation to prevent external rotation of the shoulder, which might cause secondary displacement. The objective of this study was to compare this standard immobilisation technique to a posterior plaster splint with a simple sling. Secondary displacement is not more common with a posterior plaster splint and sling than with a long arm cast. 100 patients with extension Gartland type III SCHFs managed by closed reduction and percutaneous fixation with two lateral-entry pins between December 2011 and December 2015 were assessed retrospectively. Post-operative immobilisation was with a posterior plaster splint and a simple sling worn for 4 weeks. Radiographs were obtained on days 1, 45, and 90. Secondary displacement occurred in 8% of patients. No patient required revision surgery. The secondary displacement rate was comparable to earlier reports. Of the 8 secondary displacements, 5 were ascribable to technical errors. The remaining 3 were not caused by rotation of the arm and would probably not have been prevented by using the tubular-bandage sling. A posterior plaster splint combined with a simple sling is a simple and effective immobilisation method for SCHFs provided internal fixation is technically optimal. IV, retrospective observational study. Copyright © 2018. Published by Elsevier Masson SAS.

  20. Interventions for treating proximal humeral fractures in adults.

    PubMed

    Handoll, Helen H G; Brorson, Stig

    2015-11-11

    Fracture of the proximal humerus, often termed shoulder fracture, is a common injury in older people. The management of these fractures varies widely. This is an update of a Cochrane Review first published in 2001 and last updated in 2012. To assess the effects (benefits and harms) of treatment and rehabilitation interventions for proximal humeral fractures in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and other databases, conference proceedings and bibliographies of trial reports. The full search ended in November 2014. We considered all randomised controlled trials (RCTs) and quasi-randomised controlled trials pertinent to the management of proximal humeral fractures in adults. Both review authors performed independent study selection, risk of bias assessment and data extraction. Only limited meta-analysis was performed. We included 31 heterogeneous RCTs (1941 participants). Most of the 18 separate treatment comparisons were tested by small single-centre trials. The main exception was the surgical versus non-surgical treatment comparison tested by eight trials. Except for a large multicentre trial, bias in these trials could not be ruled out. The quality of the evidence was either low or very low for all comparisons except the largest comparison.Nine trials evaluated non-surgical treatment in mainly minimally displaced fractures. Four trials compared early (usually one week) versus delayed (three or four weeks) mobilisation after fracture but only limited pooling was possible and most of the data were from one trial (86 participants). This found some evidence that early mobilisation resulted in better recovery and less pain in people with mainly minimally displaced fractures. There was evidence of little difference between the two groups in shoulder complications (2/127 early mobilisation versus 3/132 delayed mobilisation; 4 trials) and fracture displacement and non-union (2/52 versus 1/54; 2 trials).One quasi-randomised trial (28 participants) found the Gilchrist-type sling was generally more comfortable than the Desault-type sling (body bandage). One trial (48 participants) testing pulsed electromagnetic high-frequency energy provided no evidence. Two trials (62 participants) provided evidence indicating little difference in outcome between instruction for home exercises versus supervised physiotherapy. One trial (48 participants) reported, without presentable data, that home exercise alone gave better early and comparable long-term results than supervised exercise in a swimming pool plus home exercise.Eight trials, involving 567 older participants, evaluated surgical intervention for displaced fractures. There was high quality evidence of no clinically important difference in patient-reported shoulder and upper-limb function at one- or two-year follow-up between surgical (primarily locking plate fixation or hemiarthroplasty) and non-surgical treatment (sling immobilisation) for the majority of displaced proximal humeral fractures; and moderate quality evidence of no clinically important difference between the two groups in quality of life at two years (and at interim follow-ups at six and 12 months). There was moderate quality evidence of little difference between groups in mortality in the surgery group (17/248 versus 12/248; risk ratio (RR) 1.40 favouring non-surgical treatment, 95% confidence interval (CI) 0.69 to 2.83; P = 0.35; 6 trials); only one death was explicitly linked with the treatment. There was moderate quality evidence of a higher risk of additional surgery in the surgery group (34/262 versus 16/261; RR 2.06, 95% CI 1.18 to 3.60; P = 0.01; 7 trials). Although there was moderate evidence of a higher risk of adverse events after surgery, the 95% confidence intervals for adverse events also included the potential for a greater risk of adverse events after non-surgical treatment.Different methods of surgical management were tested in 12 trials. One trial (57 participants) comparing two types of locking plate versus a locking nail for treating two-part surgical neck fractures found some evidence of slightly better function after plate fixation but also of a higher rate of surgically-related complications. One trial (61 participants) comparing a locking plate versus minimally invasive fixation with distally inserted intramedullary K-wires found little difference between the two implants at two years. Compared with hemiarthroplasty, one trial (32 participants) found similar results with locking plate fixation in function and re-operation rates, whereas another trial (30 participants) reported all five re-operations occurred in the tension-band fixation group. One trial (62 participants) found better patient-rated (Quick DASH) and composite shoulder function scores at a minimum of two years follow-up and a lower incidence of re-operation and complications after reverse shoulder arthroplasty (RSA) compared with hemiarthroplasty.No important between-group differences were found in one trial (120 participants) comparing the deltoid-split approach versus deltopectoral approach for non-contact bridging plate fixation, and two trials (180 participants) comparing 'polyaxial' and 'monaxial' screws in locking plate fixation. One trial (68 participants) produced some preliminary evidence that tended to support the use of medial support locking screws in locking plate fixation. One trial (54 participants) found fewer adverse events, including re-operations, for the newer of two types of intramedullary nail. One trial (35 participants) found better functional results for one of two types of hemiarthroplasty. One trial (45 participants) found no important effects of tenodesis of the long head of the biceps for people undergoing hemiarthroplasty.Very limited evidence suggested similar outcomes from early versus later mobilisation after either surgical fixation (one trial: 64 participants) or hemiarthroplasty (one trial: 49 participants). There is high or moderate quality evidence that, compared with non-surgical treatment, surgery does not result in a better outcome at one and two years after injury for people with displaced proximal humeral fractures involving the humeral neck and is likely to result in a greater need for subsequent surgery. The evidence does not cover the treatment of two-part tuberosity fractures, fractures in young people, high energy trauma, nor the less common fractures such as fracture dislocations and head splitting fractures.There is insufficient evidence from RCTs to inform the choices between different non-surgical, surgical, or rehabilitation interventions for these fractures.

Top