Sample records for fracture fixation

  1. Biomechanical Concepts for Fracture Fixation

    PubMed Central

    Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.

    2015-01-01

    Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263

  2. A Novel Fixation System for Acetabular Quadrilateral Plate Fracture: A Comparative Biomechanical Study

    PubMed Central

    Zha, Guo-Chun; Sun, Jun-Ying; Dong, Sheng-Jie; Zhang, Wen; Luo, Zong-Ping

    2015-01-01

    This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fracture; the better biomechanical performance of the AFRIF compared with the T-shaped plate fixation (TPF), L-shaped plate fixation (LPF), and H-shaped plate fixation (HPF); AFRIF gives reasonable stability of treatment for quadrilateral plate fracture and may offer a better solution for comminuted quadrilateral plate fractures or free floating medial wall fracture and be reliable in preventing protrusion of femoral head. PMID:25802849

  3. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    PubMed

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In fractures types B and C dynamic external skeletal fixation allows early mobility in the ankle joint.

  4. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    PubMed

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.

    PubMed

    Chan, Gareth; Korac, Zelimir; Miletic, Matija; Vidovic, Dinko; Phadnis, Joideep; Bakota, Bore

    2017-11-01

    Surgical fixation of displaced midshaft clavicle fractures is predominantly achieved with intramedullary (IM) or plate fixation. Both techniques have potential pitfalls: plate fixation involves greater periosteal stripping and protuberance of the implant, whereas IM fixation may be associated with implant-related complications, such as migration or skin irritation, which may lead to further surgery for implant removal. The aim of this study was to compare these two methods in simple (Robinson 2b.1) and multifragmentary (Robinson 2b.2) displaced midshaft clavicle fractures. A total of 133 consecutive patients who underwent surgical fixation for a displaced midshaft clavicle fracture with either IM fixation using a 2.5-mm Kirschner wire or plate fixation using an 8-hole Dynamic Compression Plate (DCP) were retrospectively reviewed. Follow-up was a minimum of 1 year. The patients were allocated into two injury groups: displaced simple 2-part fractures (64 IM vs. 16 DCP) and displaced multifragmentary fractures (27 IM vs. 26 DCP). The major observed outcome measures were: infection rate, non-union rate, reoperation rate and postoperative range of motion (ROM). Rates of non-union for displaced 2-part fractures were 2/64 (3.13%) with IM fixation and 0/16 (0.00%) with plate fixation (p = 0.477). For displaced multifragmentary fractures, rates of non-union were 2/27 (7.41%) with IM fixation and 0/26 (0.00%) with plate fixation (p = 0.161). No significant difference was observed between the two fixation modalities in patient-reported time to regain ROM on the injured side for displaced 2-part fractures (p = 0.129) and displaced multifragmentary fractures (p = 0.070). Deep infection rate was zero (p = 1.000) overall in the study, and reoperation rate for IM and plate fixation, respectively, was 3.13% and 6.25% in the Robinson 2b.1 group (p = 0.559) and 7.41% and 7.69% in the Robinson 2b.2 group (p = 0.969). IM fixation of displaced midshaft clavicle fractures (Robinson 2b.1) has an equivalent non-union rate to plate fixation and similarly low complication and reoperation rates. For displaced midshaft multifragmentary clavicle fractures (Robinson 2b.2), the higher non-union rates observed with IM fixation leads us to recommend consideration of plate fixation for Robinson 2b.2 fractures. © 2017 Elsevier Ltd. All rights reserved.

  6. Intramedullary nail fixation of non-traditional fractures: Clavicle, forearm, fibula.

    PubMed

    Dehghan, Niloofar; Schemitsch, Emil H

    2017-06-01

    Locked intramedullary fixation is a well-established technique for managing long-bone fractures. While intramedullary nail fixation of diaphyseal fractures in the femur, tibia, and humerus is well established, the same is not true for other fractures. Surgical fixations of clavicle, forearm and ankle are traditionally treated with plate and screw fixation. In some cases, fixation with an intramedullary device is possible, and may be advantageous. However, there is however a concern regarding a lack of rotational stability and fracture shortening. While new generation of locked intramedullary devices for fractures of clavicle, forearm and fibula are recently available, the outcomes are not as reliable as fixation with plates and screws. Further research in this area is warranted with high quality comparative studies, to investigate the outcomes and indication of these fractures treated with intramedullary nail devices compared to intramedullary nail fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Biomechanical Evaluation of Standard Versus Extended Proximal Fixation Olecranon Plates for Fixation of Olecranon Fractures.

    PubMed

    Boden, Allison L; Daly, Charles A; Dalwadi, Poonam P; Boden, Stephanie A; Hutton, William C; Muppavarapu, Raghuveer C; Gottschalk, Michael B

    2018-01-01

    Small olecranon fractures present a significant challenge for fixation, which has resulted in development of plates with proximal extension. Olecranon-specific plates with proximal extensions are widely thought to offer superior fixation of small proximal fragments but have distinct disadvantages: larger dissection, increased hardware prominence, and the increased possibility of impingement. Previous biomechanical studies of olecranon fracture fixation have compared methods of fracture fixation, but to date there have been no studies defining olecranon plate fixation strength for standard versus extended olecranon plates. The purpose of this study is to evaluate the biomechanical utility of the extended plate for treatment of olecranon fractures. Sixteen matched pairs of fresh-frozen human cadaveric elbows were used. Of the 16, 8 matched pairs received a transverse osteotomy including 25% and 8 including 50% of the articular surface on the proximal fragment. One elbow from each pair was randomly assigned to a standard-length plate, and the other elbow in the pair received the extended-length plate, for fixation of the fracture. The ulnae were cyclically loaded and subsequently loaded to failure, with ultimate load, number of cycles, and gap formation recorded. There was no statistically significant difference between the standard and extended fixation plates in simple transverse fractures at either 25% or 50% from the proximal most portion of the articular surface of the olecranon. Standard fixation plates are sufficient for the fixation of small transverse fractures, but caution should be utilized particularly with comminution and nontransverse fracture patterns.

  8. Rigid fixation of facial fractures in children.

    PubMed

    Koltai, P J; Rabkin, D; Hoehn, J

    1995-01-01

    This article presents a retrospective analysis of a selective use of rigid fixation among 62 children with facial fractures, treated at a Level I trauma center over a 5-year period (1986-1991). There were 21 mandible fractures, 11 orbital fractures, 11 zygomaticomalar complex fractures, 7 nasal fractures, 5 maxillary fractures, 3 pan-facial fractures, 2 nasal-orbital-ethmoidal complex fractures, and 2 frontal sinus fractures. Only 18 children had rigid fixation of their injuries. Complications of Le Fort upper facial fractures repaired with rigid fixation involved perioperative sinusitis; one case required oral antibiotics, the other ethmoidectomy and maxillary antrostomy. One child with a Le Fort fracture had delayed exposure of a zygomaticomalar buttress plate, which required surgical removal. Permanent enophthalmos occurred in two children with Le Fort fractures. The authors conclude that traditional conservative management is appropriate in most cases. However, in children aged 13 and older with mandible fractures and children with complex mid- and upper facial fractures, a judicious use of rigid fixation has advantages over the traditional techniques.

  9. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    PubMed

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  10. Biomechanical principles and mechanobiologic aspects of flexible and locked plating.

    PubMed

    Claes, Lutz

    2011-02-01

    The goal of minimally invasive surgery in extramedullary internal fixation has led to the development of flexible plates, bridging plates, and locked internal fixators. The change from conventional compression plates to these new implants, however, resulted in different biomechanics of fixation and different mechanobiologic processes for fracture healing. The aim of a flexible fixation is the stimulation of fracture healing by callus formation. Fracture healing follows mechanobiologic rules based mainly on interfragmentary strain, which is dependent on the stability of the fixation construct and the type of fracture. Knowledge of the mechanobiologic processes and the factors influencing the stability of fracture fixation are necessary for the surgeon to choose the correct technique for fracture fixation. Problems in the selection of the correct technique and limitations with the available implants as well as possible future developments are discussed.

  11. Fractures of the capitellum--a comparison of two fixation methods.

    PubMed

    Poynton, A R; Kelly, I P; O'Rourke, S K

    1998-06-01

    Isolated capitellar fractures are rare, accounting for only 1 per cent of all elbow fractures (Bryan and Morrey, The Elbow and its Disorders, 1985). Many different fixation methods have been described but no series has compared these treatment modalities because of the rarity of these fractures. This paper compares the outcome of two types of fixation of type I capitellar fractures. Group one (n = 6) had open reduction and Kirschner wire fixation while group two (n = 6) had open reduction and Herbert screw fixation. Both groups were compared clinically, functionally and radiographically. We found that Herbert screw fixation enabled earlier mobilization and a better functional outcome.

  12. Novel Anterior Plating Technique for Patella Fracture Fixation.

    PubMed

    Siljander, Matthew P; Vara, Alexander D; Koueiter, Denise M; Wiater, Brett P; Wiater, Patrick J

    2017-07-01

    Patella fracture fixation remains a significant challenge for orthopedic surgeons. Although tension band fixation allows for reliable osseous union, especially in simple fracture patterns, it still presents several problems. Plate fixation of patella fractures is a method that allows for more rigid stabilization and earlier mobilization. At the authors' level 1 trauma center, one fellowship-trained trauma surgeon has transitioned to using a novel anterior, low-profile mesh plate construct for all types of patella fractures. This construct allows for stable fixation, osseous union, and neutralization of the inferior pole for even the most comminuted of patella fractures. [Orthopedics. 2017; 40(4):e739-e743.]. Copyright 2017, SLACK Incorporated.

  13. Is prophylactic fixation a cost-effective method to prevent a future contralateral fragility hip fracture?

    PubMed

    Faucett, Scott C; Genuario, James W; Tosteson, Anna N A; Koval, Kenneth J

    2010-02-01

    : A previous hip fracture more than doubles the risk of a contralateral hip fracture. Pharmacologic and environmental interventions to prevent hip fracture have documented poor compliance. The purpose of this study was to examine the cost-effectiveness of prophylactic fixation of the uninjured hip to prevent contralateral hip fracture. : A Markov state-transition model was used to evaluate the cost and quality-adjusted life-years (QALYs) for unilateral fixation of hip fracture alone (including internal fixation or arthroplasty) compared with unilateral fixation and contralateral prophylactic hip fixation performed at the time of hip fracture or unilateral fixation and bilateral hip pad protection. Prophylactic fixation involved placement of a cephalomedullary nail in the uninjured hip and was initially assumed to have a relative risk of a contralateral fracture of 1%. Health states included good health, surgery-related complications requiring a second operation (infection, osteonecrosis, nonunion, and malunion), fracture of the uninjured hip, and death. The primary outcome measure was the incremental cost-effectiveness ratio estimated as cost per QALY gained in 2006 US dollars with incremental cost-effectiveness ratios below $50,000 per QALY gained considered cost-effective. Sensitivity analyses evaluated the impact of patient age, annual mortality and complication rates, intervention effectiveness, utilities, and costs on the value of prophylactic fixation. : In the baseline analysis, in a 79-year-old woman, prophylactic fixation was not found to be cost-effective (incremental cost-effectiveness ratio = $142,795/QALY). However, prophylactic fixation was found to be a cost-effective method to prevent contralateral hip fracture in: 1) women 71 to 75 years old who had 30% greater relative risk for a contralateral fracture; and 2) women younger than age 70 years. Cost-effectiveness was greater when the additional costs of prophylaxis were less than $6000. However, for most analyses, the success of prophylactic fixation was highly sensitive to the effectiveness and the relative morbidity and mortality of the additional procedure. : Prophylactic fixation with a cephalomedullary nail was not found to be cost-effective for the average older woman who sustained a hip fracture. However, it may be appropriate for select patient populations. The study supports the need for basic science and clinical trials investigating the effectiveness of prophylactic fixation for patient populations at higher lifetime risk for contralateral hip fracture.

  14. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    PubMed Central

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  15. Application of 3D printed customized external fixator in fracture reduction.

    PubMed

    Qiao, Feng; Li, Dichen; Jin, Zhongmin; Gao, Yongchang; Zhou, Tao; He, Jinlong; Cheng, Li

    2015-01-01

    Long bone fracture is common in traumatic osteopathic patients. Good reduction is beneficial for bone healing, preventing the complications such as delayed union, nonunion, malunion, but is hard to achieve. Repeated attempts during the surgery would increase the operation time, cause new damage to the fracture site and excessive exposure to radiation. Robotic and navigation techniques can help improve the reduction accuracy, however, the high cost and complexity of operation have limited their clinical application. We combined 3D printing with computer-assisted reduction technique to develop a customised external fixator with the function of fracture reduction. The original CT data obtained by scanning the fracture was imported to computer for reconstructing and reducing the 3D image of the fracture, based on which the external fixator (named as Q-Fixator) was designed and then fabricated by 3D printing techniques. The fracture reduction and fixation was achieved by connecting the pins inserted in the bones with the customised Q-Fixator. Experiments were conducted on three fracture models to demonstrate the reduction results. Good reduction results were obtained on all three fractured bone models, with an average rotation of 1.21°(± 0.24), angulation of 1.84°(± 0.28), and lateral displacement of 2.22 mm(± 0.62). A novel customised external fixator for long bone fracture reduction was readily developed using 3D printing technique. The customised external fixator had the advantages of easy manipulation, accurate reduction, minimally invasion and experience-independence. Future application of the customised external fixator can be extended to include the fixation function with stress adjustment and potentially optimise the fracture healing process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures.

    PubMed

    Aksakal, Bunyamin; Gurger, Murat; Say, Yakup; Yilmaz, Erhan

    2014-01-01

    Biomechanical comparison of straight DCP and helical plates for fixation of transversal and oblique tibial bone fractures were analyzed and compared to each other by axial compression, bending and torsion tests. An in vitro osteosynthesis of transverse (TF) and oblique bone fracture (OF) fixations have been analysed on fresh sheep tibias by using the DCP and helical compression plates (HP). Statistically significant differences were found for both DCP and helical plate fixations under axial compression, bending and torsional loads. The strength of fixation systems was in favor of DC plating with exception of the TF-HP fixation group under compression loads and torsional moments. The transvers fracture (TF) stability was found to be higher than that found in oblique fracture (OF) fixed by helical plates (HP). However, under torsional testing, compared to conventional plating, the helical plate fixations provided a higher torsional resistance and strength. The maximum stiffness at axial compression loading and maximum torsional strength was achieved in torsional testing for the TF-HP fixations. From in vitro biomechanical analysis, fracture type and plate fixation system groups showed different responses under different loadings. Consequently, current biomechanical analyses may encourage the usage of helical HP fixations in near future during clinical practice for transverse bone fractures.

  17. A Comparison of Three Different Methods of Fixation in the Management of Thoracolumbar Fractures.

    PubMed

    Panteliadis, Pavlos; Musbahi, Omar; Muthian, Senthil; Goyal, Shivam; Montgomery, Alexander Sheriff; Ranganathan, Arun

    2017-01-01

    Management of thoracolumbar fractures remains controversial in the literature. The primary aims of this study were to assess different levels of fixation with respect to radiological outcomes in terms of fracture reduction and future loss of correction. This is a single center, retrospective study. Fifty-five patients presenting with thoracolumbar fractures between January 2012 and December 2015 were analyzed in the study. The levels of fixation were divided in 3 groups, 1 vertebra above and 1 below the fracture (1/1), 2 above and 2 below (2/2), and 2 above and 1 below (2/1). The most common mechanism was high fall injury and the most common vertebra L1. Burst fractures were the ones with the highest incidence. The 2/2 fixation achieved the best reduction of the fracture but with no statistical significance. The correction is maintained better by the 2/2 fixation but there is no statistical difference compared to the other fixations. Insertion of screws at the fracture level did not improve outcomes. The data of this study identified a trend towards better radiological outcomes for fracture reduction and maintenance of the correction in the 2/2 fixations. However these results are not statistically significant. Future multicenter prospective clinical trials are needed in order to agree on the ideal management and method of fixation for thoracolumbar fractures.

  18. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  19. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  20. Fractures of the proximal fifth metatarsal: percutaneous bicortical fixation.

    PubMed

    Mahajan, Vivek; Chung, Hyun Wook; Suh, Jin Soo

    2011-06-01

    Displaced intraarticular zone I and displaced zone II fractures of the proximal fifth metatarsal bone are frequently complicated by delayed nonunion due to a vascular watershed. Many complications have been reported with the commonly used intramedullary screw fixation for these fractures. The optimal surgical procedure for these fractures has not been determined. All these observations led us to evaluate the effectiveness of percutaneous bicortical screw fixation for treating these fractures. Twenty-three fractures were operatively treated by bicortical screw fixation. All the fractures were evaluated both clinically and radiologically for the healing. All the patients were followed at 2 or 3 week intervals till fracture union. The patients were followed for an average of 22.5 months. Twenty-three fractures healed uneventfully following bicortical fixation, with a mean healing time of 6.3 weeks (range, 4 to 10 weeks). The average American Orthopaedic Foot & Ankle Society (AOFAS) score was 94 (range, 90 to 99). All the patients reported no pain at rest or during athletic activity. We removed the implant in all cases at a mean of 23.2 weeks (range, 18 to 32 weeks). There was no refracture in any of our cases. The current study shows the effectiveness of bicortical screw fixation for displaced intraarticular zone I fractures and displaced zone II fractures. We recommend it as one of the useful techniques for fixation of displaced zone I and II fractures.

  1. A Prospective Randomized Trial to Assess Fixation Strategies for Severe Open Tibia Fractures: Modern Ring External Fixators Versus Internal Fixation (FIXIT Study).

    PubMed

    OʼToole, Robert V; Gary, Joshua L; Reider, Lisa; Bosse, Michael J; Gordon, Wade T; Hutson, James; Quinnan, Stephen M; Castillo, Renan C; Scharfstein, Daniel O; MacKenzie, Ellen J

    2017-04-01

    The treatment of high-energy open tibia fractures is challenging in both the military and civilian environments. Treatment with modern ring external fixation may reduce complications common in these patients. However, no study has rigorously compared outcomes of modern ring external fixation with commonly used internal fixation approaches. The FIXIT study is a prospective, multicenter randomized trial comparing 1-year outcomes after treatment of severe open tibial shaft fractures with modern external ring fixation versus internal fixation among men and women of ages 18-64. The primary outcome is rehospitalization for major limb complications. Secondary outcomes include infection, fracture healing, limb function, and patient-reported outcomes including physical function and pain. One-year treatment costs and patient satisfaction will be compared between the 2 groups, and the percentage of Gustilo IIIB fractures that can be salvaged without soft tissue flap among patients receiving external fixation will be estimated.

  2. Comparing Different Surgical Techniques for Addressing the Posterior Malleolus in Supination External Rotation Ankle Fractures and the Need for Syndesmotic Screw Fixation.

    PubMed

    Li, Mengnai; Collier, Rachel C; Hill, Brian W; Slinkard, Nathaniel; Ly, Thuan V

    Trimalleolar ankle fractures are unstable injuries with possible syndesmotic disruption. Recent data have described inherent morbidity associated with screw fixation of the syndesmosis, including the potential for malreduction, hardware irritation, and post-traumatic arthritis. The posterior malleolus is an important soft tissue attachment for the posterior inferior syndesmosis ligament. We hypothesized that fixation of a sizable posterior malleolar (PM) fracture in supination external rotation type IV (SER IV) ankle fractures would act to stabilize the syndesmosis and minimize or eliminate the need for trans-syndesmotic fixation. A retrospective review of trimalleolar ankle fractures surgically treated from October 2006 to April of 2011 was performed. A total of 143 trimalleolar ankle fractures were identified, and 97 were classified as SER IV. Of the 97 patients, 74 (76.3%) had a sizable PM fragment. Syndesmotic fixation was required in 7 of 34 (20%) and 27 of 40 (68%), respectively, when the PM was fixed versus not fixed (p = .0002). When the PM was indirectly reduced using an anterior to posterior screw, 7 of 15 patients (46.7%) required syndesmotic fixation compared with none of 19 patients when the PM fragment was fixated with direct posterior lateral plate fixation (p = .0012). Fixation of the PM fracture in SER IV ankle fractures can restore syndesmotic stability and, thus, lower the rate of syndesmotic fixation. We found that fixation of a sizable PM fragment in SER IV or equivalent injuries through posterolateral plating can eliminate the need for syndesmotic screw fixation. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Fracture healing using degradable magnesium fixation plates and screws.

    PubMed

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles

    2015-02-01

    Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. [Effectiveness comparison of flexible fixation and rigid fixation in treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis].

    PubMed

    Li, Yuewei; Zhang, Minghui; Li, Xiaorong; Chen, Xiaoyong; Deng, Jianlong

    2017-07-01

    To compare the effectiveness of flexible fixation and rigid fixation in the treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis. A retrospective analysis was made on the clinical data of 50 patients with ankle pronation-external rotation fractures and distal tibiofibular syndesmosis treated between January 2013 and December 2015. Suture-button fixation was used in 23 patients (flexible fixation group) and cortical screw fixation in 27 patients (rigid fixation group). There was no significant difference in age, gender, weight, side, fracture type, and time from trauma to surgery between 2 groups ( P >0.05). The operation time, medial clear space (MCS), tibiofibular clear space (TFCS), tibiofibular overlap (TFO), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Foot and Ankle Disability Index (FADI) score were compared between 2 groups. The operation time was (83.0±9.1) minutes in the flexible fixation group and was (79.6±13.1) minutes in the rigid fixation group, showing no significant difference ( t =1.052, P =0.265). All patients achieved healing of incision by first intention. The patients were followed up 12-20 months (mean, 14 months). The X-ray films showed good healing of fracture in 2 groups. There was no screw fracture, delayed union or nounion. The fracture healing time was (12.1±2.5) months in the flexible fixation group and was (11.3±3.2) months in the rigid fixation group, showing no significant difference between 2 groups ( t =1.024, P =0.192). Reduction loss occurred after removal of screw in 2 cases of the rigid fixation group. At last follow-up, there was no significant difference in MCS, TFCS, TFO, AOFAS score and FADI score between 2 groups ( P >0.05). Suture-button fixation has similar effectiveness to screw fixation in ankle function and imaging findings, and flexible fixation has lower risk of reduction loss of distal tibiofibular syndesmosis than rigid fixation.

  5. Use of Resorbable Fixation System in Pediatric Facial Fractures.

    PubMed

    Wong, Frankie K; Adams, Saleigh; Hudson, Donald A; Ozaki, Wayne

    2017-05-01

    Resorbable fixation system (RFS) is an alternative to titanium in open reduction and internal fixation of pediatric facial fractures. This study retrospectively reviewed all medical records in a major metropolitan pediatric hospital in Cape Town, South Africa from September 2010 through May 2014. Inclusion criteria were children under the age of 13 with facial fractures who have undergone open reduction and internal fixation using RFS. Intraoperative and postoperative complications were reviewed. A total of 21 patients were included in this study. Twelve were males and 9 were females. Good dental occlusion was achieved in all patients and there were no complications intraoperatively. Three patients developed postoperative implanted-related complications: all 3 patients developed malocclusions and 1 developed an additional sterile abscess over the right zygomatic bone. For the latter, incision and drainage was performed and the problem resolved without additional operations. Resorbable fixation system is an alternative to titanium products in the setting of pediatric facial fractures without complications involving delayed union or malunion. The combination of intermaxillary fixation and RFS is not needed postoperatively for adequate fixation of mandible fractures. Resorbable fixation system is able to provide adequate internal fixation when both low-stress and high-stress craniofacial fractures occur simultaneously.

  6. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    PubMed

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P < 0.05); however, there were no significant differences in radial-ulnar deviation, wrist range of motion, or wrist function score between groups (P > 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  7. Long-bone fractures in llamas and alpacas: 28 cases (1998–2008)

    PubMed Central

    Knafo, S. Emmanuelle; Getman, Liberty M.; Richardson, Dean W.; Fecteau, Marie-Eve

    2012-01-01

    Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998–2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids. PMID:23277645

  8. Long-bone fractures in llamas and alpacas: 28 cases (1998-2008).

    PubMed

    Knafo, S Emmanuelle; Getman, Liberty M; Richardson, Dean W; Fecteau, Marie-Eve

    2012-07-01

    Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998-2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids.

  9. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    PubMed

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  10. Biomechanical comparison of straight and helical compression plates for fixation of transverse and oblique bone fractures: Modeling and experiments.

    PubMed

    Sezek, Sinan; Aksakal, Bunyamin; Gürger, Murat; Malkoc, Melih; Say, Y

    2016-08-12

    Total deformation and stability of straight and helical compression plates were studied by means of the finite element method (FEM) and in vitro biomechanical experiments. Fixations of transverse (TF) and oblique (45°) bone (OF) fractures have been analyzed on sheep tibias by designing the straight compression (SP) and Helical Compression Plate (HP) models. The effects of axial compression, bending and torsion loads on both plating systems were analyzed in terms of total displacements. Numerical models and experimental models suggested that under compression loadings, bone fracture gap closures for both fracture types were found to be in the favor of helical plate designs. The helical plate (HP) fixations provided maximum torsional resistance compared to the (SP) fixations. The fracture gap closure and stability of helical plate fixation for transverse fractures was determined to be higher than that found for the oblique fractures. The comparison of average compression stress, bending and torsion moments showed that the FEM and experimental results are in good agreement and such designs are likely to have a positive impact in future bone fracture fixation designs.

  11. [Comparison of external fixation with or without limited internal fixation for open knee fractures].

    PubMed

    Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S

    2018-03-01

    Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P <0.05). Take a single cross joint external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60.5%, 15 cases were more than 50 points, accounting for 39.5%, external fixation and limited internal fixation group 20 cases were less than 50 points, accounting for 41.7%, 28 cases were more than 50 points, accounting for 58.3%; There was significant difference between the two groups(χ(2)=1.279, P >0.05). Conclusions: Prevention and control of infection is a central link in the treatment of open fracture of the knee. Trans articular external fixator plus limited internal fixation is an important measure to treat open fracture of the knee-joint.

  12. Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures.

    PubMed

    Ni, Ming; Wong, Duo Wai-Chi; Mei, Jiong; Niu, Wenxin; Zhang, Ming

    2016-09-01

    The locking plate and percutaneous crossing metallic screws and crossing absorbable screws have been used clinically to treat intra-articular calcaneal fractures, but little is known about the biomechanical differences between them. This study compared the biomechanical stability of calcaneal fractures fixed using a locking plate and crossing screws. Three-dimensional finite-element models of intact and fractured calcanei were developed based on the CT images of a cadaveric sample. Surgeries were simulated on models of Sanders type III calcaneal fractures to produce accurate postoperative models fixed by the three implants. A vertical force was applied to the superior surface of the subtalar joint to simulate the stance phase of a walking gait. This model was validated by an in vitro experiment using the same calcaneal sample. The intact calcaneus showed greater stiffness than the fixation models. Of the three fixations, the locking plate produced the greatest stiffness and the highest von Mises stress peak. The micromotion of the fracture fixated with the locking plate was similar to that of the fracture fixated with the metallic screws but smaller than that fixated with the absorbable screws. Fixation with both plate and crossing screws can be used to treat intra-articular calcaneal fractures. In general, fixation with crossing metallic screws is preferable because it provides sufficient stability with less stress shielding.

  13. Free flap reconstructions of tibial fractures complicated after internal fixation.

    PubMed

    Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S

    1995-04-01

    The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.

  14. Patella Fracture Fixation with Suture and Wire: you Reap what you Sew

    PubMed Central

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Introduction Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. Methods In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Results Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26 - 88 years). Patients had an average BMI of 26.48 (range 19 - 44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36 fractures repaired with a tension band fixation, 11 underwent secondary surgery due to hardware pain or fixation failure (30.6%). At one year, no difference was seen in knee range of motion between cohorts. All fractures healed radiographically. Those patients who required reoperation or removal of hardware had significantly diminished range of motion about their injured knee (p > 0.005). Conclusions Patients who sustain inferior pole patella fractures have limited options for fracture fixation. Suture repair is clinically acceptable, yielding similar results to patella fractures repaired with metal implants. Importantly, patients undergoing suture repair appear to have fewer hardware related postoperative complications than those receiving wire fixation for midpole fractures. PMID:25328461

  15. Patella fracture fixation with suture and wire: you reap what you sew.

    PubMed

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26-88 years). Patients had an average BMI of 26.48 (range 19-44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36 fractures repaired with a tension band fixation, 11 underwent secondary surgery due to hardware pain or fixation failure (30.6%). At one year, no difference was seen in knee range of motion between cohorts. All fractures healed radiographically. Those patients who required reoperation or removal of hardware had significantly diminished range of motion about their injured knee (p > 0.005). Patients who sustain inferior pole patella fractures have limited options for fracture fixation. Suture repair is clinically acceptable, yielding similar results to patella fractures repaired with metal implants. Importantly, patients undergoing suture repair appear to have fewer hardware related postoperative complications than those receiving wire fixation for midpole fractures.

  16. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    PubMed

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  17. External fixation techniques for distal radius fractures.

    PubMed

    Capo, John T; Swan, Kenneth G; Tan, Virak

    2006-04-01

    Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. Level V (expert opinion).

  18. Intramedullary Fixation of Midshaft Clavicle Fractures.

    PubMed

    Fritz, Erik M; van der Meijden, Olivier A; Hussain, Zaamin B; Pogorzelski, Jonas; Millett, Peter J

    2017-08-01

    Clavicle fractures are among the most common fractures occurring in the general population, and the vast majority are localized in the midshaft portion of the bone. Management of midshaft clavicle fractures remains controversial. Although many can be managed nonoperatively, certain patient populations and fracture patterns, such as completely displaced and shortened fractures, are at risk of less optimal outcomes with nonoperative management; surgical intervention should be considered in such cases. The purpose of this article is to demonstrate our technique of midshaft clavicle fixation using minimally invasive intramedullary fixation.

  19. Evaluation of functional outcome of pilon fractures managed with limited internal fixation and external fixation: A prospective clinical study.

    PubMed

    Meena, Umesh Kumar; Bansal, Mahesh Chand; Behera, Prateek; Upadhyay, Rahul; Gothwal, Gyan Chand

    2017-11-01

    The management of pilon fractures is controversial primarily due to the high rate of complications irrespective of the mode of treatment. Limited internal fixation with external fixation is associated with minimal soft tissue handling. This may reduce the chances of wound dehiscence and infection. This study was designed to evaluate the functional and clinical outcomes in patients treated with limited internal fixation combined with external fixation in pilon fractures. This study was conducted as a prospective clinical study on 56 skeletally mature patients with closed fractures with poor skin condition, and with open grade 1 and grade 2 distal tibial intra-articular fractures. All patients were treated with combined limited internal fixation and ankle spanning external fixation. All fractures in this series united with an average time period of union of 18.3weeks (ranging from 13 weeks to 30 weeks). There was no non-union in any case. There was malunion in 4 cases, varus malunion (>5 degree) in 2 cases and recurvatum in another 2 cases). Excellent to good functional results were observed in 88% cases based on the modified Ovadia and Beals score. The mean ankle dorsiflexion and planter flexion movements were 10.2±5.3 degrees and 27.4±7.2 degrees respectively. infections occurred in 6 patients which included 4 pin tract infections and 2 superficial wound infection, all 6 healed after removal of pin tract and with oral antibiotics. The technique of combined external fixation with internal fixation is safe and effective management option for intra-articular distal tibial fractures.

  20. Numerical Simulation of Callus Healing for Optimization of Fracture Fixation Stiffness

    PubMed Central

    Steiner, Malte; Claes, Lutz; Ignatius, Anita; Simon, Ulrich; Wehner, Tim

    2014-01-01

    The stiffness of fracture fixation devices together with musculoskeletal loading defines the mechanical environment within a long bone fracture, and can be quantified by the interfragmentary movement. In vivo results suggested that this can have acceleratory or inhibitory influences, depending on direction and magnitude of motion, indicating that some complications in fracture treatment could be avoided by optimizing the fixation stiffness. However, general statements are difficult to make due to the limited number of experimental findings. The aim of this study was therefore to numerically investigate healing outcomes under various combinations of shear and axial fixation stiffness, and to detect the optimal configuration. A calibrated and established numerical model was used to predict fracture healing for numerous combinations of axial and shear fixation stiffness under physiological, superimposed, axial compressive and translational shear loading in sheep. Characteristic maps of healing outcome versus fixation stiffness (axial and shear) were created. The results suggest that delayed healing of 3 mm transversal fracture gaps will occur for highly flexible or very rigid axial fixation, which was corroborated by in vivo findings. The optimal fixation stiffness for ovine long bone fractures was predicted to be 1000–2500 N/mm in the axial and >300 N/mm in the shear direction. In summary, an optimized, moderate axial stiffness together with certain shear stiffness enhances fracture healing processes. The negative influence of one improper stiffness can be compensated by adjustment of the stiffness in the other direction. PMID:24991809

  1. Numerical simulation of callus healing for optimization of fracture fixation stiffness.

    PubMed

    Steiner, Malte; Claes, Lutz; Ignatius, Anita; Simon, Ulrich; Wehner, Tim

    2014-01-01

    The stiffness of fracture fixation devices together with musculoskeletal loading defines the mechanical environment within a long bone fracture, and can be quantified by the interfragmentary movement. In vivo results suggested that this can have acceleratory or inhibitory influences, depending on direction and magnitude of motion, indicating that some complications in fracture treatment could be avoided by optimizing the fixation stiffness. However, general statements are difficult to make due to the limited number of experimental findings. The aim of this study was therefore to numerically investigate healing outcomes under various combinations of shear and axial fixation stiffness, and to detect the optimal configuration. A calibrated and established numerical model was used to predict fracture healing for numerous combinations of axial and shear fixation stiffness under physiological, superimposed, axial compressive and translational shear loading in sheep. Characteristic maps of healing outcome versus fixation stiffness (axial and shear) were created. The results suggest that delayed healing of 3 mm transversal fracture gaps will occur for highly flexible or very rigid axial fixation, which was corroborated by in vivo findings. The optimal fixation stiffness for ovine long bone fractures was predicted to be 1000-2500 N/mm in the axial and >300 N/mm in the shear direction. In summary, an optimized, moderate axial stiffness together with certain shear stiffness enhances fracture healing processes. The negative influence of one improper stiffness can be compensated by adjustment of the stiffness in the other direction.

  2. Single-screw Fixation of Adolescent Salter-II Proximal Humeral Fractures: Biomechanical Analysis of the "One Pass Door Lock" Technique.

    PubMed

    Miller, Mark Carl; Redman, Christopher N; Mistovich, R Justin; Muriuki, Muturi; Sangimino, Mark J

    2017-09-01

    Pin fixation of Salter-II proximal humeral fractures in adolescents approaching skeletal maturity has potential complications that can be avoided with single-screw fixation. However, the strength of screw fixation relative to parallel and diverging pin fixation is unknown. To compare the biomechanical fixation strength between these fixation modalities, we used synthetic composite humeri, and then compared these results in composite bone with cadaveric humeri specimens. Parallel pinning, divergent pinning, and single-screw fixation repairs were performed on synthetic composite humeri with simulated fractures. Six specimens of each type were tested in axial loading and other 6 were tested in torsion. Five pair of cadaveric humeri were tested with diverging pins and single screws for comparison. Single-screw fixation was statistically stronger than pin fixation in axial and torsional loading in both composite and actual bone. There was no statistical difference between composite and cadaveric bone specimens. Single-screw fixation can offer greater stability to adolescent Salter-II fractures than traditional pinning. Single-screw fixation should be considered as a viable alternative to percutaneous pin fixation in transitional patients with little expected remaining growth.

  3. Use of resorbable plates and screws in pediatric facial fractures.

    PubMed

    Eppley, Barry L

    2005-03-01

    The use of resorbable plates and screws for fixation of pediatric facial fractures is both well tolerated and effective. It enables realignment and stable positioning of rapidly healing fracture segments while obviating any future issues secondary to long-term metal retention. Forty-four pediatric facial fractures were treated over a 10-year period at our institution using differing techniques of polymeric bone fixation. Twenty-nine mandible fractures in patients under the age of 10 (age range, 6 months to 8 years) were treated. Displaced fractures of the symphysis, parasymphysis, body, and ramus underwent open reduction and either 1.5-mm or 2.0-mm plate and screw fixation in 14 patients. Subcondylar fractures were treated by a short period of maxillomandibular fixation (3 weeks) achieved with suture ligation between resorbable screws placed at the zygoma and symphysis or a circummandibular suture attached to a zygomatic screw. Fifteen patients (age range, 4 to 11 years) with isolated frontal, supraorbital, intraorbital, or orbitozygomatic fractures were treated by open reduction and internal fixation with 1.5-mm resorbable plates, mesh, and screws. No long-term implant-related complications were seen in any of the treated patients. Resorbable polylactic and polyglycolic acid plates and screws can be an effective fixation method for facial fractures in children in the primary and secondary dentition periods.

  4. Treatment of femoral shaft fractures with monoaxial external fixation in polytrauma patients

    PubMed Central

    Testa, Gianluca; Aloj, Domenico; Ghirri, Alessandro; Petruccelli, Eraclite; Pavone, Vito; Massé, Alessandro

    2017-01-01

    Background: Femoral shaft fractures, typical in younger people, are often associated with polytrauma followed by traumatic shock. In these situations, despite intramedullary nailing being the treatment of choice, external fixation could be used as the definitive treatment. The aim of this study is to report evidence regarding definitive treatment of femoral shaft fractures with monoaxial external fixation. Methods: Between January 2006 and December 2015, 83 patients with 87 fractures were treated at the Department of Orthopaedics and Traumatology CTO of Turin, with a monoaxial external fixation device. Mean age at surgery, type of fracture, mean follow-up, time and modalities of treatment, non-weight bearing period, average healing, external fixation removal time, and complications were reported. Results: The average patient age was 31.43±15.19 years. In 37 cases (42.53%) the right femur was involved. 73 (83.91%) fractures were closed, and 14 (16.09%) were open. The average follow-up time was 61.07±21.86 weeks.  In 68 (78.16%) fractures the fixation was carried out in the first 24 hours, using a monoaxial external fixator. In the remaining 19 cases, the average delay was 6.80±4.54 days. Mean non-weight bearing time was 25.82±27.66 days (ranging from 0 to 120). The 87 fractures united at an average of 23.60±11.37 weeks (ranging from 13 to 102). The external fixator was removed after an average of 33.99±14.33 weeks (ranging from 20 to 120). Reported complications included 9.19% of delayed union, 1.15% of septic non-union, 5.75% of malunion, and 8.05% cases of loss of reduction. Conclusions: External fixation of femoral shaft fractures in polytrauma is an ideal method for definitive fracture stabilization, with minimal additional operative trauma and an acceptable complication rate. PMID:28928953

  5. Plate fixation or intramedullary fixation for midshaft clavicle fractures: a systematic review and meta-analysis of randomized controlled trials and observational studies.

    PubMed

    Houwert, Roderick M; Smeeing, Diederik P J; Ahmed Ali, Usama; Hietbrink, Falco; Kruyt, Moyo C; van der Meijden, Olivier A

    2016-07-01

    The last decade has shown a shift toward operative treatment of a subset of midshaft clavicle fractures. However, it is unclear whether there are differences between plate fixation and intramedullary fixation regarding complications and functional outcome. The aim of this systematic review and meta-analysis was to compare plate fixation and intramedullary fixation for midshaft clavicle fractures. The Medline, Embase, and Cochrane databases were searched for both randomized controlled trials and observational studies. The methodologic quality of all included studies was assessed using the Methodological Index for Non-Randomized Studies. Twenty studies were included. Ten of the 20 included studies used a fracture classification. Seven of these studies reported exclusion of patients with comminuted fractures. No difference in the total re-intervention rate was found (odds ratio [OR], 1.21; 95% confidence interval [CI], 0.71 to 2.04). Major re-interventions occurred more often after plate fixation (OR, 1.88; 95% CI, 1.02 to 3.46). The mean implant removal rates were 38% after plate fixation and 73% after intramedullary fixation. Re-fracture after implant removal occurred more often after plate fixation (OR, 3.42; 95% CI, 1.12 to 10.42). The Constant-Murley scores showed no differences at both short term (mean difference, -1.18; 95% CI, -13.41 to 11.05) and long term (mean difference, 0.15; 95% CI, -1.57 to 1.87). No differences were observed regarding nonunion (OR, 1.50; 95% CI, 0.82 to 2.75). The rate of infections showed no differences when outlier studies were excluded (OR, 1.54; 95% CI, 0.88 to 2.69). Major re-intervention and re-fracture after implant removal occurred more frequently after plate fixation of non-comminuted, displaced midshaft clavicle fractures. No differences in terms of function and nonunion between plate fixation and intramedullary fixation were observed. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins under epidural anesthesia].

    PubMed

    Liu, Jinliang; Li, Keyao; Ju, Zhenlong; Bai, Yan

    2011-03-01

    To study the indications, methods and experience of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. 52 cases with multiple rib fractures were performed internal fixation with absorbable rib-connecting-pins under epidural anesthesia. All cases were followed up for 1 to 12 months, with an average of 5 months. All fractures were achieved healing in 3 to 6 months after the operation and were not found chest wall deformity. Absorbable rib-connecting-pins fixation is a simple and effective method and worthies recommending to perform operation for the appropriate cases with multiple rib fractures.

  7. Suture Anchor Fixation for Fifth Metatarsal Tuberosity Avulsion Fractures: A Case Series and Review of Literature.

    PubMed

    Hong, Choon Chiet; Nag, Kushal; Yeow, Huifen; Lin, Adrian Zhigao; Tan, Ken Jin

    2018-05-17

    Fifth metatarsal tuberosity avulsion fractures are common. Despite good outcomes with nonoperative treatment, acute fractures with displacement, intra-articular involvement, comminution, or painful nonunion have been reported to benefit from early open reduction and internal fixation, especially in athletes. No consensus has been reached regarding the best surgical fixation technique. We present a case series of 4 patients with displaced fifth metatarsal tuberosity avulsion fractures and an innovative technique of fixation for the tuberosity avulsion fractures using a suture anchor. Copyright © 2018 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Treatment of Early Post-Op Wound Infection after Internal Fixation

    DTIC Science & Technology

    2017-10-01

    the fracture stable while the bone heals. Approximately 10%-40% of severe fractures fixed with internal fixation develop a deep wound infection during...effect of treatment of post-op wound infection in bones after fracture fixation or joint fusion and either: (Group 1) operative debridement and PO

  9. History of internal fixation (part 1): early developments with wires and plates before World War II.

    PubMed

    Hernigou, Philippe; Pariat, Jacques

    2017-06-01

    Though the date at which an orthopaedic implant was first used cannot be ascertained with any certainty, the fixation of bone fracture using an iron wire was reported for the first time in a French manuscript in 1775. The first techniques of operative fracture treatment were developed at the end of the 18th and in the beginning of the 19th centuries. The use of cerclage wires to fix fractures was the most frequent fixation at this time. The French Berenger-Feraud (1832-1900) had written the first book on internal fixation. However internal fixation of fractures could not become a practical method before Lister had ensured the safety of open reduction and internal fixation in the treatment of fractures. Lister is not only the father of asepsis; he also used metal wires to fix even closed fractures. The first internal fixation by means of a plate and screws was described by Carl Hansmann in 1858 in Hamburg. Nevertheless, Arbuthnot Lane (1892) and Albin Lambotte (1905) are considered to be the founders of this method, which was further developed by Sherman in the first part of the 20th century.

  10. Medial malleolar fractures: a biomechanical study of fixation techniques.

    PubMed

    Fowler, T Ty; Pugh, Kevin J; Litsky, Alan S; Taylor, Benjamin C; French, Bruce G

    2011-08-08

    Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO group recommends tension-band fixation of small avulsion type fractures of the medial malleolus that are unacceptable for screw fixation. A well-documented complication of this technique is prominent symptomatic implants and secondary surgery for implant removal. Replacing stainless steel 18-gauge wire with FiberWire suture could theoretically decrease symptomatic implants. Therefore, a second goal was to biomechanically compare these 2 tension-band constructs. Using a tibial Sawbones model, 2 bicortical screws were compared with 2 unicortical cancellous screws on a servohydraulic test frame in offset axial, transverse, and tension loading. Second, tension-band fixation using stainless steel wire was compared with FiberWire under tensile loads. Bicortical screw fixation was statistically the stiffest construct under tension loading conditions compared to unicortical screw fixation and tension-band techniques with FiberWire or stainless steel wire. In fact, unicortical screw fixation had only 10% of the stiffness as demonstrated in the bicortical technique. In a direct comparison, tension-band fixation using stainless steel wire was statistically stiffer than the FiberWire construct. Copyright 2011, SLACK Incorporated.

  11. Relative stability of tension band versus two-cortex screw fixation for treating fifth metatarsal base avulsion fractures.

    PubMed

    Husain, Z S; DeFronzo, D J

    2000-01-01

    This study assesses the strength of fixating avulsion fractures of the fifth metatarsal base with a 4.0-mm partially threaded cancellous screw crossing two cortices as compared to tension banding. Our data showed statistically significant fixation strength improvement over tension banding for avulsion fractures (p < 0.02) in both polystyrene foam models and fresh, nonpreserved frozen cadaveric samples. In cadavers, the screw fixations were able to withstand more than three times the load sustained by the tension band fixations. The study utilized the Instron 8500 tensiometer to apply physiologic loads to test the constructs until failure. The displacement and load data at failure show the limitations of both fixations. By increasing the load resistance while maintaining compression, the bicortical cancellous screw fixation created greater stability at the avulsion fracture of the fifth metatarsal base as compared to tension band stabilization.

  12. Outcomes of Internal Fixation in a Combat Environment

    DTIC Science & Technology

    2010-01-01

    analyzed. Forty-seven patients had internal fixation performed on 50 fractures in a combat theater hospital. Hip, forearm, and ankle fractures made up the...limited number of fracture patterns associated with a significant risk of failure if definitive treatment is delayed (4). Because of the limited...Injuries Hip, forearm, and ankle fractures made up the majority of internal fixation cases with 14 (28%), 14 (28%), and 10 TABLE 1 Mechanism of

  13. Operative Fixation of Rib Fractures Indications, Techniques, and Outcomes.

    PubMed

    Galos, David; Taylor, Benjamin; McLaurin, Toni

    2017-01-01

    Rib fractures are extremely common injuries and vary in there severity from single nondisplaced fractures to multiple segmental fractures resulting in flail chest and respiratory compromise. Historically, rib fractures have been treated conservatively with pain control and respiratory therapy. However this method may not be the best treatment modality in all situations. Operative fixation of select rib fractures has been increasing in popularity especially in patients with flail chest and respiratory compromise. Newer techniques use muscle sparing approaches and precontoured locking plate technology to obtain stable fixation and allow improved respiration. Current reports shows that rib fracture fixation offers the benefits of improved respiratory mechanics and improved pain control in the severe chest wall injury with resultant improvement in patient outcomes by decreasing time on the ventilator, time in the intensive care unit, and overall hospital length of stay.

  14. Interpretation of Post-operative Distal Humerus Radiographs After Internal Fixation: Prediction of Later Loss of Fixation.

    PubMed

    Claessen, Femke M A P; Stoop, Nicky; Doornberg, Job N; Guitton, Thierry G; van den Bekerom, Michel P J; Ring, David

    2016-10-01

    Stable fixation of distal humerus fracture fragments is necessary for adequate healing and maintenance of reduction. The purpose of this study was to measure the reliability and accuracy of interpretation of postoperative radiographs to predict which implants will loosen or break after operative treatment of bicolumnar distal humerus fractures. We also addressed agreement among surgeons regarding which fracture fixation will loosen or break and the influence of years in independent practice, location of practice, and so forth. A total of 232 orthopedic residents and surgeons from around the world evaluated 24 anteroposterior and lateral radiographs of distal humerus fractures on a Web-based platform to predict which implants would loosen or break. Agreement among observers was measured using the multi-rater kappa measure. The sensitivity of prediction of failure of fixation of distal humerus fracture on radiographs was 63%, specificity was 53%, positive predictive value was 36%, the negative predictive value was 78%, and accuracy was 56%. There was fair interobserver agreement (κ = 0.27) regarding predictions of failure of fixation of distal humerus fracture on radiographs. Interobserver variability did not change when assessed for the various subgroups. When experienced and skilled surgeons perform fixation of type C distal humerus fracture, the immediate postoperative radiograph is not predictive of fixation failure. Reoperation based on the probability of failure might not be advisable. Diagnostic III. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Radiographic prevalence of CAM-type femoroacetabular impingement after open reduction and internal fixation of femoral neck fractures.

    PubMed

    Mathew, G; Kowalczuk, M; Hetaimish, B; Bedi, A; Philippon, M J; Bhandari, M; Simunovic, N; Crouch, S; Ayeni, O R

    2014-04-01

    The purpose of this study was to estimate the radiographic prevalence of CAM-type femoroacetabular impingement (FAI) in elderly patients (≥ 50 years) who have undergone internal fixation for femoral neck fracture. A total of 187 frog-leg lateral radiographs of elderly patients who underwent internal fixation for a femoral neck fracture were reviewed by two independent reviewers. The alpha angle, beta angle, and femoral head-neck offset ratio were calculated. The presence of two abnormal radiographic parameters was deemed to be diagnostic of radiographic CAM-type impingement. Radiographic CAM-type FAI was identified in 157 out of 187 (84 %) patients who underwent internal fixation for fractures of the femoral neck. Moderate-to-good inter-observer reliability was achieved in the measurement of radiographic parameters. With reference to fracture subtypes and prevalence of radiographic features of CAM-type morphology, 97 (72 %) out of 134 patients were positive for CAM in Garden subtypes I and II, whereas 49 (85.9 %) out of 57 patients had radiographic CAM in Garden III and IV subtypes. There was a high prevalence of CAM-type FAI in patients that underwent surgical fixation of femoral neck fractures. This is significantly higher than the reported prevalence in non-fracture patient populations. The high prevalence of CAM morphology could be related to several factors, including age, fracture morphology, quality of reduction, type of fixation, and fracture healing.

  16. [Miniplate internal fixation and autogenous iliac bone graft in surgical treatment of old metatarsal fractures].

    PubMed

    Pan, Hao; Yu, Guangrong; Xiong, Wen; Zhao, Zhiming; Ding, Fan; Zheng, Qiong; Kan, Wushen

    2011-07-01

    To summarize the experience of treating old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone. Between May 2009 and July 2010, 7 patients with old metatarsal fractures were treated surgically, including 5 multi-metatarsal fractures and 2 single metatarsal fractures. There were 5 males and 2 females aged from 25 to 43 years (mean, 33 years). The time from fracture to operation was 4-12 weeks. The X-ray films showed that a small amount of callus formed at both broken ends with shortening, angulation, or rotation displacement. The surgical treatments included open reduction, internal fixation by miniplate, and autogenous iliac bone graft (1.5-2.5 cm(3)). The external plaster fixation was used in all patients for 4 to 6 weeks postoperatively (mean, 5 weeks). All incisions healed by first intention. The 7 patients were followed up 8-18 months (mean, 13.5 months). The clinical fracture healing time was 6 to 12 weeks postoperatively (mean, 8.4 weeks). No pain of planta pedis occurred while standing and walking. The American Orthopaedic Foot and Ankle Society (AOFAS) mesopedes and propodium score was 75-96 (mean, 86.4). It has the advantages of reliable internal fixation, high fracture healing rate, less complications to treat old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone graft, so it is an effective treatment method.

  17. Surgical Management of Rib Fractures: Strategies and Literature Review.

    PubMed

    de Jong, M B; Kokke, M C; Hietbrink, F; Leenen, L P H

    2014-06-01

    Rib fractures can cause significant problems in trauma patients, often resulting in pain and difficulty with respiration. To prevent pulmonary complications and decrease the morbidity and mortality rates of patients with rib fractures, currently there is a trend to provide surgical management of patients with flail chest. However, the indications for rib fracture fixation require further specification. Past and current strategies are described according to a review of the medical literature. A systematic review was performed including current indications for rib fracture fixation. MEDLINE (2000-2013) was searched, as well as Embase (2000-2013) and Cochrane Databases, using the keywords rib, fracture, fixation, plate, repair, and surgery. Three retrospective studies were found that described different techniques for rib fracture fixation. The results demonstrated a reduced number of ventilation days, decreased long-term morbidity and pain, and satisfactory rehabilitation after surgical treatment. In addition to flail chest, age, Injury Severity Score, and the number of rib fractures were important predictive factors for morbidity and mortality. Surgical rib fracture fixation might be indicated in a broader range of cases than is currently performed. Prospective randomized trials are needed for further confirmation. © The Finnish Surgical Society 2014.

  18. Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

    PubMed

    Perry, C R; McCarthy, J A; Kain, C C; Pearson, R L

    1988-01-01

    The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standard fixation techniques (interfragmentary cancellous screws or modified tension-band wiring) alone failed after significantly fewer cycles of flexion and extension than did the same fixation when supplemented with a load-sharing cable. In the clinical evaluation of the load-sharing cable, 14 consecutive patients with displaced patellar fractures were treated. No immobilization was used and the patients were started on passive and active range of motion and weight-bearing ambulation in the early postoperative period. Thirteen fractures healed uneventfully. The increased stability of patellar fracture fixation protected with a load-sharing cable offers three advantages: (a) adjunctive casting is unnecessary, (b) comminuted fractures can be "pieced" together anatomically with less concern for loss of fixation, and (c) early postoperative passive and active range of motion can be achieved.

  19. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    PubMed

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  20. Volar plate fixation failure for volar shearing distal radius fractures with small lunate facet fragments.

    PubMed

    Beck, John D; Harness, Neil G; Spencer, Hillard T

    2014-04-01

    To determine the percentage of AO B3 distal radius fractures that lose reduction after operative fixation and to see whether fracture morphology, patient factors, or fixation methods predict failure. We hypothesized that initial fracture displacement, amount of lunate facet available for fixation, plate position, and screw fixation would be significant risk factors for loss of reduction. A prospective, observational review was conducted of 51 patients (52 fractures) with AO B3 (volar shearing) distal radius fractures treated operatively between January 2007 and June 2012. We reviewed a prospective distal radius registry to determine demographic data, medical comorbidities, and physical examination findings. Radiographs were evaluated for AO classification, loss of reduction, length of volar cortex available for fixation, and adequacy of stabilization of the lunate facet fragment with a volar plate. Preoperative data were compared between patients who maintained radiographic alignment and those with loss of reduction. A multivariate logistic regression analysis was completed to determine significant predictors of loss of reduction. Volar shearing fractures with separate scaphoid and lunate facet fragments (AO B3.3), preoperative lunate subsidence distance, and length of volar cortex available for fixation were significant predictors for loss of reduction; the latter was significant in multivariate analysis. Plate position and number of screws used to stabilize the lunate facet were not statistically different between groups. Patients with AO B3.3 fractures with less than 15 mm of lunate facet available for fixation, or greater than 5 mm of initial lunate subsidence, are at risk for failure even if a volar plate is properly placed. In these cases, we recommend additional fixation to maintain reduction of the small volar lunate facet fracture fragments in the form of plate extensions, pins, wires, suture, wire forms, or mini screws. Therapeutic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    PubMed

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  2. Conversion of external fixation to open reduction and internal fixation for complex distal radius fractures.

    PubMed

    Natoli, R M; Baer, M R; Bednar, M S

    2016-05-01

    Distal radius fractures are common injuries treated in a multitude of ways. One treatment paradigm not extensively studied is initial treatment by external fixation (EF) followed by conversion to open reduction internal fixation (ORIF). Such a paradigm may be beneficial in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. There is no increased risk of infection when converting EF to ORIF in the treatment of complex distal radius fractures when conversion occurs early or if EF pin sites are overlapped by the definitive fixation. Using an IRB approved protocol, medical records over nine years were queried to identify patients with distal radius fractures that had undergone initial EF and were later converted to ORIF. Charts were reviewed for demographic data, injury characteristics, operative details, time to conversion from EF to ORIF, assessment of whether the EF pin sites overlapped the definitive fixation, presence of infection after ORIF, complications, and occupational therapy measurements of range of motion and strength. In total, 16 patients were identified, only one of which developed an infection following conversion to ORIF. Fisher's exact testing showed that infection did not depend on open fracture, time to conversion of one week or less, presence of EF pin sites overlapping definitive fixation, fracture classification, high energy mechanism of injury, or concomitant injury to the DRUJ. Planned staged conversion from EF to ORIF for complex distal radius fractures does not appear to result in an increased rate of infection if conversion occurs early or if the EF pin sites are overlapped by definitive fixation. This treatment paradigm may be reasonable for treating complex distal radius fractures in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. IV, retrospective case series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. Outcome of 28 open pilon fractures with injury severity-based fixation.

    PubMed

    Danoff, Jonathan R; Saifi, Comron; Goodspeed, David C; Reid, J Spence

    2015-04-01

    Open pilon fracture management and treatment poses a significant challenge to orthopedic surgeons. The purpose of this study was to determine patient outcomes for open pilon fractures based on wound complication and infection rates, as well as subjective outcome instruments. This was a retrospective consecutive case series of 28 fractures with Orthopaedic Trauma Association (OTA)-type 43-B and 43-C open pilon fractures. Mean length of follow-up was 36 months and minimum of 1 year. Ten fractures were Gustilo and Anderson grade IIIB, and the remaining fractures were grades I-IIIA. Patients were initially treated with spanning external fixation and staged wound debridement followed by osteosynthesis of the articular surface. Metaphyseal fixation was by either plate fixation or Ilizarov frame. The primary outcome was the incidence of deep tissue infection requiring surgery. Secondary outcomes included the incidence of other complications (nonunion, malunion, amputation) and functional outcomes (Short Musculoskeletal Functional Assessment Questionnaire and AAOS Foot and Ankle Questionnaire). Four patients developed deep tissue infections, three in the internal fixation group and one in the Ilizarov group, and all were treated successfully with staged debridement. There were two delayed unions required bone grafting, and infection-free union was ultimately achieved in all fractures. Two patients underwent arthrodesis secondary to post-traumatic arthritis, while no patients experienced malunions or amputations. The use of staged wound debridement in conjunction with either plate fixation or Ilizarov frame achieves low rates of wound infection and stable fixation after anatomic joint reconstruction for OTA-type 43-B and 43-C open pilon fractures.

  4. Modified Judet approach and minifragment fixation of scapular body and glenoid neck fractures.

    PubMed

    Jones, Clifford B; Cornelius, Jonathan P; Sietsema, Debra L; Ringler, James R; Endres, Terrence J

    2009-09-01

    To describe the technique and to determine the outcome of operatively treated displaced scapular body or glenoid neck fractures using minifragment fixation through a modified Judet approach. Retrospective review of scapular or glenoid fractures. Level 1 teaching trauma center. All treated scapular or glenoid fractures over 7 years (1999-2005) were determined. Of a total of 227 scapular or glenoid fractures, 37 were treated with open reduction internal fixation and formed the basis of study. All patients were followed for a minimum of 1 year until healing or discharge from care. All operatively treated scapular fractures were performed in the lateral position on a radiolucent table. A modified Judet approach was used in all patients. The posterior deltoid was incised off the scapular spine cephalad reaching the lateral scapular border. The interval between the teres minor and infraspinatus was paramount for fracture reduction and implant insertion. The 2.7-mm minifragment plates were applied along the lateral border of the scapula. Radiographic assessment of fracture healing and clinical assessment of shoulder function. The majority of patients were males (31 males, 6 females) who sustained blunt trauma. All scapular fractures maintained fixation and reduction. No wound or muscle dehiscence problems were noted. Average range of motion was 158 degrees (range 90-180 degrees). There were no fixation failures or instances of implant loosening. The modified Judet approach allows for excellent scapular and glenoid fracture visualization and reduction while preserving rotator cuff function. Minifragment fixation along the lateral scapular border provides excellent plate position, screw length, and fracture stability.

  5. Outcomes of internal fixation in a combat environment.

    PubMed

    Stinner, Daniel J; Keeney, James A; Hsu, Joseph R; Rush, Jeremy K; Cho, Mickey S; Wenke, Joseph C; Ficke, James R

    2010-01-01

    Due to the nature of the wounds and environment, internal fixation in battlefield treatment facilities is discouraged despite the lack of data. The purpose of this review is to describe the outcomes of fractures that were internally fixed in the combat environment. The records of patients who had internal fixation performed in the theater of combat operations were reviewed. Demographics, injury characteristics, procedure history, and outcomes were recorded and analyzed. Forty-seven patients had internal fixation performed on 50 fractures in a combat theater hospital. Hip, forearm, and ankle fractures made up the majority of cases with 14 (28%), 14 (28%), and 10 (20%), respectively. Sixteen (32%) fractures were open. The average Injury Severity Score was 11.4 +/- 1.1 (range, 4-34). Thirty-nine fractures (78%) healed without incidence. There was one (2%) infection and one (2%) acute surgical complication. Ten (20%) fractures, including the one infection, required additional procedures. Because internal fixation in the combat environment was used judiciously, complications were not higher than previously reported.

  6. Pediatric distal femur fixation by proximal humeral plate.

    PubMed

    Abdelgawad, Amr Atef; Kanlic, Enes M

    2013-12-01

    Distal femoral metaphyseal fractures are common injuries in children. Multiple treatment options have been described for this type of injury. For older children with distal metaphyseal fracture, there is still no optimal method of fixation. We propose that the commonly used proximal humeral plate can provide good method of fixation for this fracture in adolescents. Two children (12 and 14 years old) with distal metaphyseal femoral fracture were treated with proximal humeral plate. We describe the surgical technique and postoperative management. The two children healed with good alignment and full range of motion of the knee. No external immobilization (other than knee immobilizer for the first 2 weeks) was used. We concluded that proximal humeral plate can provide adequate fixation for teenagers with distal femoral metaphyseal fracture. It is readily available; provide multiple options for screw fixation in the distal part of the fracture and fits easily on the distal part of the femur proximal to the physis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. [Surgical treatment of tibial nonunion after wounding by high velocity missile and external fixators: a case report].

    PubMed

    Golubović, Ivan; Vukašinović, Zoran; Stojiljković, Predrag; Golubović, Zoran; Stojiljković, Danilo; Radovanović, Zoran; Ilić, Nenad; Najman, Stevo; Višnjić, Aleksandar; Arsić, Stojanka

    2012-01-01

    The missiles of modern firearms can cause severe fractures of the extremity. High velocity missile fractures of the tibia are characterized by massive tissue destruction and primary contamination with polymorphic bacteria. Treatment of these fractures is often complicated by delayed healing, poor position healing, nonhealing and bone tissue infection. We present the management of tibial nonunion after wounding by high velocity missile and primary treatment by external fixation in a 25-year-old patient. The patient was primarily treated with external fixation and reconstructive operations of the soft tissue without union of the fracture. Seven months after injury we placed a compression-distraction external fixator type Mitkovic and started with compression and distraction in the fracture focus after osteotomy of the fibula and autospongioplasty. We recorded satisfactory fracture healing and good functional outcome. Contamination and devitalization of the soft-tissue envelope increase the risk of infection and nonunion in fractures after wounding by high velocity missile. The use of the compression-distraction external fixator type Mitkovic may be an effective method in nonunions of the tibia after this kind of injury.

  8. Temporary Iliac Fixation to Salvage an Acute L4 Chance Fracture: Following Pedicle Screw Fixation for Adolescent Idiopathic Scoliosis.

    PubMed

    Kato, So; Lewis, Stephen J

    2017-03-01

    A case report. The aim of this study was to describe a technique of temporary distal fixation to the ilium to salvage an acute L4 fracture following a T3-L4 kyphoscoliosis correction. Pedicle fracture is a possible complication in pedicle screw fixation for scoliosis, which may lead to postoperative instability, resulting in loss of fixation and pseudoarthrosis. This report highlights the salvage treatment of a chance fracture that occurred in the lower instrumented vertebra following deformity correction for adolescent idiopathic scoliosis (AIS) without sacrificing further distal motion segments. A retrospective chart and radiograph review of a 13-year-old female who underwent surgical treatment for correction of AIS was performed. Following a T3-L4 correction with apical posterior column releases, an L4 Chance fracture with loss of distal fixation occurred on post-op day 3. Following an unsuccessful salvage with an infralaminar hook, a second revision was performed replacing the hook and adding bilateral temporary fixation to the ilium connected to the distal ends of the main rods through side-to-side connectors. The temporary fixation was removed 6 months later with successful healing of the fracture maintenance of the scoliosis correction at 2-year follow-up. Temporary extension of the construct to the ilium was successfully utilized in this case to salvage an acute L4 Chance fracture that occurred following a T3 to L4 construct for kyphoscoliosis. With this technique, successful reduction and healing of the fracture occurred with maintenance of the deformity correction without the need to fuse further distal segments. 4.

  9. Complications associated with operative fixation of acute midshaft clavicle fractures.

    PubMed

    Asadollahi, Saeed; Hau, Raphael C; Page, Richard S; Richardson, Martin; Edwards, Elton R

    2016-06-01

    The aim of this study was to review the complication rate and profile associated with surgical fixation of acute midshaft clavicle fracture in a large cohort of patients treated in a level I trauma centre. We identified all patients who underwent surgical treatment of acute midshaft clavicle fracture between 2002 and 2010. The study group consisted of 138 fractures (134 patients) and included 107 men (78%) and 31 women (22%); the median age of 35 years (interquartile range (IQR) 24-45). The most common mechanism of injury was a road traffic accident (78%). Sixty percent (n=83) had an injury severity score of ≥15 indicating major trauma. The most common fracture type (75%) was simple or wedge comminuted (2B1) according to the Edinburgh classification. The median interval between the injury and operation was 3 days (IQR 1-6). Plate fixation was performed in 110 fractures (80%) and intramedullary fixation was performed in 28 fractures (20%). There were 85 men and 25 women in the plate fixation group with median age of 35 years (IQR 25-45) There were 22 men and six women in the intramedullary fixation group with median age of 31 years (IQR 24-42 years). Statistical analysis was performed using independent sample t test, Mann Whitney test, and Chi square test. Significant P-value was <0.05. The overall incidence of complication was 14.5% (n=20). The overall nonunion rate was 6%. Postoperative wound infection occurred in 3.6% of cases. The incidence of complication associated with plate fixation was 10% (11 of 110 cases) compared to 32% associated with intramedullary fixation (nine of 28 cases; P=0.003). Thirty-five percent of complications were related to inadequate surgical technique and were potentially avoidable. Symptomatic hardware requiring removal occurred in 23% (n=31) of patients. Symptomatic metalware was more frequent after plate fixation compared to intramedullary fixation (26% vs 7%, P=0.03). Intramedullary fixation of midshaft clavicle fracture is associated with a higher incidence of complications. Plate fixation is associated with a higher rate of symptomatic metalware requiring removal compared to intramedullary fixation. Approximately one in three complications may be avoided by attention to adequate surgical technique. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Double row anchor fixation: a novel technique for a diabetic calanceal insufficiency avulsion fracture.

    PubMed

    Greenhagen, Robert M; Highlander, Peter D; Burns, Patrick R

    2012-01-01

    Avulsion fractures of the calcaneal tuberosity represent only 1.3% to 2.7% of calcaneal fractures. These fractures are common pathologically in nature and attributed to decreased bone mineral density. Calcaneal insufficiency avulsion (CIA) fracture in patients with diabetes mellitus is most likely due to Charcot neuroarthropathy (CN) as described by the Brodsky classification (Brodsky 3B). Traditional open reduction and internal fixation is difficult in all calcaneal avulsion fractures because of poor bone quality. The authors report the first known description of the use of fracture fragment excision and double row anchor fixation.A 39-year-old woman with type I diabetes mellitus and a history of CN presented with an avulsion fracture of the calcaneal tuberosity. Excision of the fracture fragment and a gastrocnemius recession and reattachment of the Achilles tendon with double row anchor fixation to the calcaneus were performed. At 1 year, the patient's American Orthopaedic Foot & Ankle Society rearfoot score improved from 27/100 to 88/100. CIA fractures are an infrequently described injury. Because diabetes mellitus is frequently associated with this disease, it most likely represents a CN event. Traditionally, CIA fractures have been operatively treated with open reduction internal fixation. Previous authors have described difficulty with fixation because of poor quality. In the current report, the authors describe a novel operative approach to CIA fractures through the use of double row anchor fixation and excision of the fracture fragments. The authors feel that this previously undescribed treatment is superior to traditional methods and may serve as a new treatment option for all patients who have sustained this unusual pathology regardless of the underlying cause. The current authors provide a novel operative technique that provides inherent advantages to the traditional repair of CIA fractures. We believe CIA fractures represent a CN-type event and care should be taken when evaluating and treating these patients to prevent further sequelae. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Pediatric mandibular fractures treated by rigid internal fixation.

    PubMed

    Wong, G B

    1993-09-01

    Mandibular fractures in the pediatric patient population are relatively uncommon. These patients present with their own unique treatment requirements. Most fractures have been treated conservatively by dental splints. Closed reduction techniques with maxillomandibular fixation (MMF) in very young children can pose several concerns, including cooperation, compliance and adequate nutritional intake. Rigid internal fixation of unstable mandibular fractures using miniplates and screws circumvents the need for MMF and allows immediate jaw mobilization. At major pediatric trauma institutions, there has been an increasing trend toward the use of this treatment when open reduction is necessary. This article presents a report of a five-year-old child who presented with bilateral mandibular fractures and was treated by rigid internal fixation and immediate mandibular mobilization.

  12. Tension band suture fixation for olecranon fractures.

    PubMed

    Phadnis, Joideep; Watts, Adam C

    2017-10-01

    Olecranon fractures are common and often require surgical treatment when displaced. Traditional methods of stabilization using tension band wire fixation and plate fixation achieve adequate union and function but are associated with a high rate of re-operation and wound problems because of prominent metalwork. The purpose of the present article is to describe an all suture technique for fixation of simple olecranon fractures that maintains inter-fragmentary compression, provides bony union and reduces the rate of re-operation caused by prominent metalwork.

  13. Screw-Wire Osteo-Traction: An Adjunctive or Alternative Method of Anatomical Reduction of Multisegment Midfacial Fractures? A Description of Technique and Prospective Study of 40 Patients

    PubMed Central

    O'Regan, Barry; Devine, Maria; Bhopal, Sats

    2013-01-01

    Stable anatomical fracture reduction and segment control before miniplate fixation can be difficult to achieve in comminuted midfacial fractures. Fracture mobilization and reduction methods include Gillies elevation, malar hook, and Dingman elevators. No single method is used universally. Disadvantages include imprecise segment alignment and poor segment stability/control. We have employed screw-wire osteo-traction (SWOT) to address this problem. A literature review revealed two published reports. The aims were to evaluate the SWOT technique effectiveness as a fracture reduction method and to examine rates of revision fixation and plate removal. We recruited 40 consecutive patients requiring open reduction and internal fixation of multisegment midfacial fractures (2009–2012) and employed miniplate osteosynthesis in all patients. SWOT was used as a default reduction method in all patients. The rates of successful fracture reduction achieved by SWOT alone or in combination and of revision fixation and plate removal, were used as outcome indices of the reduction method effectiveness. The SWOT technique achieved satisfactory anatomical reduction in 27/40 patients when used alone. Other reduction methods were also used in 13/40 patients. No patient required revision fixation and three patients required late plate removal. SWOT can be used across the midface fracture pattern in conjunction with other methods or as a sole reduction method before miniplate fixation. PMID:24436763

  14. A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model.

    PubMed

    Alluri, Ram K; Bougioukli, Sofia; Stevanovic, Milan; Ghiassi, Alidad

    2017-09-01

    To compare the biomechanical properties of second versus third metacarpal distal fixation when using a radiocarpal spanning distraction plate in an unstable distal radius fracture model. Biomechanical evaluation of the radiocarpal spanning distraction plate comparing second versus third metacarpal distal fixation was performed using a standardized model of an unstable wrist fracture in 10 matched-pair cadaveric specimens. Each fixation construct underwent a controlled cyclic loading protocol in flexion and extension. The resultant displacement and stiffness were calculated at the fracture site. After cyclic loading, each specimen was loaded to failure. The stiffness, maximum displacement, and load to failure were compared between the 2 groups. Cyclic loading in flexion demonstrated that distal fixation to the third metacarpal resulted in greater stiffness compared with the second metacarpal. There was no significant difference between the 2 groups with regards to maximum displacement at the fracture site in flexion. Cyclic loading in extension demonstrated no significant difference in stiffness or maximum displacement between the 2 groups. The average load to failure was similar for both groups. Fixation to the third metacarpal resulted in greater stiffness in flexion. All other biomechanical parameters were similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a spanning internal distraction plate. The treating surgeon should choose distal metacarpal fixation primarily based on fracture pattern, alignment, and soft tissue integrity. If a stiffer construct is desired, placement of the radiocarpal spanning plate at the third metacarpal is preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Management of civilian ballistic fractures.

    PubMed

    Seng, V S; Masquelet, A C

    2013-12-01

    The management of ballistic fractures, which are open fractures, has often been studied in wartime and has benefited from the principles of military surgery with debridement and lavage, and the use of external fixation for bone stabilization. In civilian practice, bone stabilization of these fractures is different and is not performed by external fixation. Fifteen civilian ballistic fractures, Gustilo II or IIIa, two associated with nerve damage and none with vascular damage, were reviewed. After debridement and lavage, ten internal fixations and five conservative treatments were used. No superficial or deep surgical site infection was noted. Fourteen of the 15 fractures (93%) healed without reoperation. Eleven of the 15 patients (73%) regained normal function. Ballistic fractures have a bad reputation due to their many complications, including infections. In civilian practice, the use of internal fixation is not responsible for excessive morbidity, provided debridement and lavage are performed. Civilian ballistic fractures, when they are caused by low-velocity firearms, differ from military ballistic fractures. Although the principle of surgical debridement and lavage remains the same, bone stabilization is different and is similar to conventional open fractures. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  16. Open reduction-internal fixation of a navicular body fracture with dorsal displacement of the first and second cuneiforms: a case report.

    PubMed

    Andersen, Robert C; Neiderer, Katherine; Martin, Billy; Dancho, James

    2013-01-01

    Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. He underwent open reduction internal fixation of the navicular body fracture successfully but failed adequate reduction of the navicular cuneiform joint after ligamentous reconstruction. After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.

  17. Open fractures caused by high velocity missiles: the outcome of treatment of 39 fractures followed for 1-3 years.

    PubMed

    Khan, M A; Hussain, R; Khan, S H; Umar, M

    1997-11-01

    Between 1993 and 1995, thirty-three patients having 39 fractures caused by missiles fired from a high velocity rifle were reviewed retrospectively between 1 and 3 years after injury and the outcome of treatment assessed. Majority (33 out of 39) were Grade III. Union was achieved in 35 out of 39 fractures, there was deep infection and delayed union in one case each. Non-union occurred in three fractures. The fractures were stabilized using different techniques, but highest complication rate was seen with the use of the static external fixator. This was related to the severe nature of the injury as well as the inherent limitations of the external fixator. Revision of the external fixator with internal fixation after healing of the soft tissues seems to be the direction of the future.

  18. Lag screw fixation of anterior mandibular fractures: a retrospective analysis of intraoperative and postoperative complications.

    PubMed

    Tiwana, Paul S; Kushner, George M; Alpert, Brian

    2007-06-01

    To review, retrospectively, the outcomes of 102 patients who underwent lag screw technique fixation of fractures of the anterior mandible. A total of 102 consecutive, skeletally mature patients who have undergone open reduction internal fixation for fractures of the anterior mandible utilizing the lag screw technique were reviewed. All patients had a clinically mobile fracture between the mental foramina of the mandible. The patients were followed at usual postoperative intervals with shortest long-term follow-up of 2 months. Intraoperative and long-term postoperative outcomes including status of union, infection, and intraoperative surgical misadventure were recorded. Data from the 102 patients showed that there was 1 fixation failure due to inappropriate patient selection, 1 nonunion requiring bone grafting, 1 with infected screws but with union, 1 with an infected screw and delayed union treated conservatively, and 6 with broken drills from intraoperative surgical misadventures. Lag screw osteosynthesis of anterior mandibular fractures is a sensitive, facile, predictable, and relatively inexpensive method for internal fixation of indicated fractures. As with all methods of rigid internal fixation, most failures or complications are the result of operator judgment or technique.

  19. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    PubMed

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. A novel fixation system for sacroiliac dislocation fracture: internal fixation system design and biomechanics analysis.

    PubMed

    Dawei, Tian; Na, Liu; Jun, Lei; Wei, Jin; Lin, Cai

    2013-02-01

    Although there were many different types of fixation techniques for sacroiliac dislocation fracture, the treat remained challenging in posterior pelvic ring injury. The purpose of this study was to evaluate the biomechanical effects of a novel fixation system we designed. 12 human cadavers (L3-pelvic-femora) were used to compare biomechanical stability after reconstruction on the same specimens in four conditions: (1) intact, (2) cable system, (3) plate-pedicle screw system, and (4) cable system and plate-pedicle screw combination system (combination system). Biomechanical testing was performed on a material testing machine for evaluating the stiffness of the pelvic fixation construct in compression and torsion. The cable system and plate-pedicle screw system alone may be insufficient to resist vertical shearing and rotational loads; however the combination system for unstable sacroiliac dislocation fractures provided significantly greater stability than single plate-pedicle or cable fixation system. The novel fixation system for unstable sacroiliac dislocation fractures produced sufficient stability in axial compression and axial rotation test in type C pelvic ring injuries. It may also offer a better solution for sacroiliac dislocation fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    PubMed

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  2. Design and Optimization of Resorbable Silk Internal Fixation Devices

    NASA Astrophysics Data System (ADS)

    Haas, Dylan S.

    Limitations of current material options for internal fracture fixation devices have resulted in a large gap between user needs and hardware function. Metal systems offer robust mechanical strength and ease of implantation but require secondary surgery for removal and/or result in long-term complications (infection, palpability, sensitivity, etc.). Current resorbable devices eliminate the need for second surgery and long-term complications but are still associated with negative host response as well as limited functionality and more difficult implantation. There is a definitive need for orthopedic hardware that is mechanically capable of immediate fracture stabilization and fracture fixation during healing, can safely biodegrade while allowing complete bone remodeling, can be resterilized for reuse, and is easily implantable (self-tapping). Previous work investigated the use of silk protein to produce resorbable orthopedic hardware for non- load bearing fracture fixation. In this study, silk orthopedic hardware was further investigated and optimized in order to better understand the ability of silk as a fracture fixation system and more closely meet the unfulfilled market needs. Solvent-based and aqueous-based silk processing formulations were cross-linked with methanol to induce beta sheet structure, dried, autoclaved and then machined to the desired device/geometry. Silk hardware was evaluated for dry, hydrated and fatigued (cyclic) mechanical properties, in vitro degradation, resterilization, functionalization with osteoinductive molecules and implantation technique for fracture fixation. Mechanical strength showed minor improvements from previous results, but remains comparable to current resorbable fixation systems with the advantages of self-tapping ability for ease of implantation, full degradation in 10 months, ability to be resterilized and reused, and ability to release molecules for osteoinudction. In vivo assessment confirmed biocompatibility, showed improved bone deposition and remodeling with functionalization and showed promising feasibility of fracture fixations with minor adjustments to geometry. The proposed silk orthopedic hardware exhibits high potential as a resorbable fixation system that can bridge the gap between the current materials for internal fixation devices.

  3. An Alternative Method of Intermaxillary Fixation for Simple Pediatric Mandible Fractures.

    PubMed

    Farber, Scott J; Nguyen, Dennis C; Harvey, Alan A; Patel, Kamlesh B

    2016-03-01

    Mandibular fractures represent a substantial portion of facial fractures in the pediatric population. Pediatric mandibles differ from their adult counterparts in the presence of mixed dentition. Avoidance of injury to developing tooth follicles is critical. Simple mandibular fractures can be treated with intermaxillary fixation (IMF) using arch bars or bone screws. This report describes an alternative to these methods using silk sutures and an algorithm to assist in treating simple mandibular fractures in the pediatric population. A retrospective chart review was performed and the records of 1 surgeon were examined. Pediatric patients who underwent treatment for a mandibular fracture in the operating room from 2011 to 2015 were identified using Common Procedural Terminology codes. Data collected included age, gender, type of fracture, type of treatment used, duration of fixation, and presence of complications. Five patients with a mean age of 6.8 years at presentation were identified. Fracture types were unilateral fractures of the condylar neck (n = 3), bilateral fractures of the condylar head (n = 1), and a unilateral fracture of the condylar head with an associated parasymphyseal fracture (n = 1). IMF was performed in 4 patients using silk sutures, and bone screw fixation was performed in the other patient. No post-treatment complications or malocclusion were reported. Average duration of IMF was 18.5 days. An algorithm is presented to assist in the treatment of pediatric mandibular fractures. Silk suture fixation is a viable and safe alternative to arch bars or bone screws for routine mandibular fractures. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    PubMed Central

    Vasiliadis, Elias S; Grivas, Theodoros B; Psarakis, Spyridon A; Papavasileiou, Evangelos; Kaspiris, Angelos; Triantafyllopoulos, Georgios

    2009-01-01

    Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate. PMID:19754962

  5. Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

    PubMed Central

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    The incidence of condylar fractures is high, but the management of fractures of the mandibular condyle continues to be controversial. Historically, maxillomandibular fixation, external fixation, and surgical splints with internal fixation systems were the techniques commonly used in the treatment of the fractured mandible. Condylar fractures can be extracapsular or intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on the age of the patient, the co-existence of other mandibular or maxillary fractures, whether the condylar fracture is unilateral or bilateral, the level and displacement of the fracture, the state of dentition and dental occlusion, and the surgeonnds on the age of the patient, the co-existence of othefrom which it is difficult to recover aesthetically and functionally;an appropriate treatment is required to reconstruct the shape and achieve the function ofthe uninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, and complication prevention are required. In particular, as mandibular condyle fracture may cause long-term complications such as malocclusion, particularly open bite, reduced posterior facial height, and facial asymmetry in addition to chronic pain and mobility limitation, great caution should be taken. Accordingly, the authors review a general overview of condyle fracture. PMID:22872830

  6. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    PubMed

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  7. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].

    PubMed

    Luo, Zhongchun; Lou, Hua; Jiang, Junwei; Song, Chunlin; Gong, Min; Wang, Yongcai

    2008-08-01

    To investigate the clinical results of treating leg open fracture with soft tissue defect by pedicle flap transfer in combination with external fixator. From May 2004 to June 2007, 12 cases of leg open fracture with soft tissue defect, 9 males and 3 females aged 18-75 years, were treated. Among them, 8 cases were caused by traffic accidents, 2 crush, 1 falling and 1 mechanical accident. According to the Gustilo Classification, there were 2 cases of type II, 5 of type IIIA and 5 of type IIIB. There were 2 cases of upper-tibia fracture, 3 of middle-tibia and 7 of middle-lower. The sizes of soft tissue defect ranged from 5 cm x 3 cm to 22 cm x 10 cm.The sizes of exposed bone ranged from 3 cm x 2 cm to 6 cm x 3 cm. The course of the disease was 1-12 hours. Fracture fixation was reached by external fixators or external fixators and limited internal fixation with Kirschner wire. The wounds with exposed tendons and bones were repaired by ipsilateral local rotation flap, sural neurocutaneous flap and saphenous nerve flap. The size of selected flap ranged from 5 cm x 4 cm to 18 cm x 12 cm. Granulation wounds were repaired by skin grafting or direct suture. All patients were followed up for 6 months to 2 years. All patients survived, among whom 2 with the wound edge infection and 1 with the distal necrosis were cured by changing the dressing, 8 with pin hole infection were treated by taking out the external fixator, 1 with nonunion received fracture healing after bone graft in comminuted fracture of lower tibia, 2 suffered delayed union in middle-lower tibia fracture. The ROM of ankle in 3 cases was mildly poor with surpass-joint fixation, with plantar extension of 0-10 degrees and plantar flexion of 10-30 degrees, while the others had plantar extension of 10-20 degrees and plantar flexion of 30-50 degrees. The method of pedicle flap transfer combined with external fixator is safe and effective for the leg open fracture with soft tissue defect.

  8. Inverted distal clavicle anatomic locking plate for displaced medial clavicle fracture.

    PubMed

    Wang, Yong; Jiang, Jiannong; Dou, Bin; Zhang, Panjun

    2015-09-01

    Fractures of the medial clavicle are rare injuries. Recently, open reduction and internal fixation has been recommended for displaced medial clavicle fractures in order to prevent non-union and dysfunction. Because of the rarity of this injury, the optimal fixation device has not yet been established. In this report, we describe a case of a 40-year-old male patient who sustained a significantly displaced medial clavicle fracture treated by open reduction and internal fixation using an inverted distal clavicle anatomic locking plate. At the 12 months follow-up, the patient recovered well, had returned to pre-injury job, and was quite satisfied with the outcome. Internal fixation of medial clavicle fracture using an inverted distal clavicle anatomic locking plate of the ipsilateral side appears to be a good treatment option.

  9. Operative Cost Comparison: Plating Versus Intramedullary Fixation for Clavicle Fractures.

    PubMed

    Hanselman, Andrew E; Murphy, Timothy R; Bal, George K; McDonough, E Barry

    2016-09-01

    Although clavicle fractures often heal well with nonoperative management, current literature has shown improved outcomes with operative intervention for specific fracture patterns in specific patient types. The 2 most common methods of midshaft clavicle fracture fixation are intramedullary and plate devices. Through retrospective analysis, this study performed a direct cost comparison of these 2 types of fixation at a single institution over a 5-year period. Outcome measures included operative costs for initial surgery and any hardware removal surgeries. This study reviewed 154 patients (157 fractures), and of these, 99 had intramedullary fixation and 58 had plate fixation. A total of 80% (79 of 99) of intramedullary devices and 3% (2 of 58) of plates were removed. Average cost for initial intramedullary placement was $2955 (US dollars) less than that for initial plate placement (P<.001); average cost for removal was $1874 less than that for plate removal surgery (P=.2). Average total cost for all intramedullary surgeries was $1392 less than the average cost for all plating surgeries (P<.001). Average cost for all intramedullary surgeries requiring plate placement and removal was $653 less than the average cost for all plating surgeries that involved only placement (P=.04). Intramedullary fixation of clavicle fractures resulted in a statistically significant cost reduction compared with plate fixation, despite the incidence of more frequent removal surgeries. [Orthopedics.2016; 39(5):e877-e882.]. Copyright 2016, SLACK Incorporated.

  10. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures.

    PubMed

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2015-09-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3-12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact.

  11. Operative stabilization of open long bone fractures: A tropical tertiary hospital experience

    PubMed Central

    Ifesanya, Adeleke O.; Alonge, Temitope O.

    2012-01-01

    Background: Operative treatment of open fractures in our environment is fraught with problems of availability of theater space, appropriate hardware, and instrumentation such that high complication rates may be expected. Materials and Methods: We evaluated all open long bone fractures operatively stabilized at our center to determine the outcome of the various treatment modalities as well as the determinant factors. Result: A total of 160 patients with 171 fractures treated between December 1995 and December 2008 were studied. There were twice as many males; mean age was 35.0 years. About half were open tibia fractures. Gustilo IIIa and IIIb fractures each accounted for 56 cases (45.2%). Fifty-three percent were stabilized within the first week of injury. Interval between injury and operative fixation averaged 11.1 days. Anderson-Hutchin's technique was employed in 27 cases (21.8%), external fixation in 21 (16.9%), plate osteosynthesis in 50 (40.3%), and intramedullary nail 15 cases (12.1%). Mean time to union was 24.7 weeks. Fifty-two complications occurred in 50 fractures (40.3%) with joint stiffness and chronic osteomyelitis each accounting for a quarter of the complications. Union was delayed in grade IIIb open fractures and those fractures treated with external fixation. Conclusion: A significant proportion of open long bone fractures we operatively treated were severe. Severe open fractures (type IIIb) with concomitant stabilization using external fixation delayed fracture union. While we recommend intramedullary devices for open fractures, in our setting where locking nails are not readily available, external fixation remains the safest choice of skeletal stabilization particularly when contamination is high. PMID:23271839

  12. Operative fixation of chest wall fractures: an underused procedure?

    PubMed

    Richardson, J David; Franklin, Glen A; Heffley, Susan; Seligson, David

    2007-06-01

    Chest wall fractures, including injuries to the ribs and sternum, usually heal spontaneously without specific treatment. However, a small subset of patients have fractures that produce overlying bone fragments that may produce severe pain, respiratory compromise, and, if untreated mechanically, result in nonunion. We performed open reduction and internal fixation on seven patients with multiple rib fractures-five in the initial hospitalization and two delayed--as well as 35 sternal fractures (19 immediate fixation and 16 delayed). Operative fixation was accomplished using titanium plates and screws in both groups of patients. All patients with rib fractures did well; there were no major complications or infections, and no plates required removal. Clinical results were excellent. There was one death in the sternal fracture group in a patient who was ventilator-dependent preoperatively and extubated himself in the early postoperative period. Otherwise, the results were excellent, with no complications occurring in this group. Three patients had their plates removed after boney union was achieved. No evidence of infection or nonunion occurred. The excellent results achieved in the subset of patients with severe chest wall deformities treated initially at our institution and those referred from outside suggest that operative fixation is a useful modality that is likely underused.

  13. Posterior Temporary Fixation Versus Nonoperative Treatment for Anderson-D'Alonzo Type III Odontoid Fractures: Functional Computed Tomography Evaluation of C1-C2 Rotation.

    PubMed

    Guo, Qunfeng; Wang, Liang; Lu, Xuhua; Guo, Xiang; Ni, Bin

    2017-04-01

    To evaluate differences in radiologic and functional outcomes between C1-C2 posterior temporary fixation (PTF) and cephalocervicothoracic cast fixation for type III odontoid fractures. Data from 13 patients who underwent PTF and 13 cases who underwent cephalocervicothoracic cast fixation due to fresh type III odontoid fractures were reviewed retrospectively. All patients with fracture healing underwent a functional computed tomography scan at the final follow-up to evaluate the range of motion in C1-C2 rotation. Functional outcomes were evaluated in the form of visual analog scale for neck pain, neck stiffness, patient satisfaction, and Neck Disability Index. The outcomes were compared between the 2 groups. At the final follow up, all 26 patients achieved healing of their fractures. There were no complications associated with either treatment. The left-to-right ranges of motion of C1-C2 rotation were 41.9° ± 11.9° in the PTF group and 43.5° ± 12.0° in the cephalocervicothoracic cast fixation group. There was no statistical difference between the 2 groups regarding the C1-C2 rotation angle (P > 0.05). There also were no significant differences between 2 groups in functional outcomes evaluated by visual analog scale for neck pain, neck stiffness, Neck Disability Index, and patient satisfaction (all P > 0.05). The outcomes of PTF and cephalocervicothoracic cast fixation were comparable in the treatment of type III odontoid fractures. For type III odontoid fractures that cannot be managed by nonoperative fixation or anterior screw fixation, PTF may be the treatment of choice, because it spares the motion of the C1-C2 complex. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Computer-assisted virtual preoperative planning in orthopedic surgery for acetabular fractures based on actual computed tomography data.

    PubMed

    Wang, Guang-Ye; Huang, Wen-Jun; Song, Qi; Qin, Yun-Tian; Liang, Jin-Feng

    2016-12-01

    Acetabular fractures have always been very challenging for orthopedic surgeons; therefore, appropriate preoperative evaluation and planning are particularly important. This study aimed to explore the application methods and clinical value of preoperative computer simulation (PCS) in treating pelvic and acetabular fractures. Spiral computed tomography (CT) was performed on 13 patients with pelvic and acetabular fractures, and Digital Imaging and Communications in Medicine (DICOM) data were then input into Mimics software to reconstruct three-dimensional (3D) models of actual pelvic and acetabular fractures for preoperative simulative reduction and fixation, and to simulate each surgical procedure. The times needed for virtual surgical modeling and reduction and fixation were also recorded. The average fracture-modeling time was 45 min (30-70 min), and the average time for bone reduction and fixation was 28 min (16-45 min). Among the surgical approaches planned for these 13 patients, 12 were finally adopted; 12 cases used the simulated surgical fixation, and only 1 case used a partial planned fixation method. PCS can provide accurate surgical plans and data support for actual surgeries.

  15. Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing.

    PubMed

    Dexel, Julian; Fritzsche, Hagen; Beyer, Franziska; Harman, Melinda K; Lützner, Jörg

    2017-03-01

    Open-wedge high tibial osteotomy (HTO) is an established treatment for young and middle-aged patients with medial compartment knee osteoarthritis and varus malalignment. Although not intended, a lateral cortex fracture might occur during this procedure. Different fixation devices are available to repair such fractures. This study was performed to evaluate osteotomy healing after fixation with two different locking plates. Sixty-nine medial open-wedge HTO without bone grafting were followed until osteotomy healing. In patients with an intact lateral hinge, no problems were noted with either locking plate. A fracture of the lateral cortex occurred in 21 patients (30.4 %). In ten patients, the fracture was not recognized during surgery but was visible on the radiographs at the 6-week follow-up. Lateral cortex fracture resulted in non-union with the need for surgical treatment in three out of eight (37.5 %) patients using the newly introduced locking plate (Position HTO Maxi Plate), while this did not occur with a well-established locking plate (TomoFix) (0 out of 13, p = 0.023). With regard to other adverse events, no differences between both implants were observed. In cases of lateral cortex fracture, fixation with a smaller locking plate resulted in a relevant number of non-unions. Therefore, it is recommended that bone grafting, another fixation system, or an additional lateral fixation should be used in cases with lateral cortex fracture. III.

  16. Treatment of inherently unstable open or infected fractures by open wound management and external skeletal fixation.

    PubMed

    Ness, M G

    2006-02-01

    To assess the use of external skeletal fixation with open wound management for the treatment of inherently unstable open or infected fractures in dogs. A retrospective review of 10 cases. Fracture stabilisation and wound management required only a single anaesthetic, and despite the challenging nature of these injuries, the final outcome was acceptable or good in every case. However, minor complications associated with the fixator pins were quite common, and two dogs developed complications which required additional surgery. Open management of wounds, even when bone was exposed, proved to be an effective technique, and external skeletal fixators were usually effective at maintaining stability throughout an inevitably extended fracture healing period.

  17. Comparison of Clinical Efficacy of Lateral and Lateral and Medial Double-plating Fixation of Distal Femoral Fractures.

    PubMed

    Bai, Zhibiao; Gao, Shichang; Hu, Zhenming; Liang, Anlin

    2018-03-20

    The present study was performed to compare the clinical efficacy of lateral plate and lateral and medial double-plating fixation of distal femoral fractures and explore the indication of lateral and medial double-plating fixation of the distal femoral fractures. From March 2006 to April 2014, 48 and 12 cases of distal femoral fractures were treated with lateral plate (single plate) and lateral and medial plates (double plates), respectively. During the surgery, after setting the lateral plate for the distal femoral fractures, if the varus stress test of the knee was positive and the lateral collateral ligament rupture was excluded, lateral and medial double-plating fixation was used for the stability of the fragments. All the patients were followed up at an average period of 15.9 months. The average operation time, the intraoperative hemorrhage and the fracture union time of the two groups were compared. One year after operation, knee function was evaluated by the Kolmert's standard. There was no significant difference in the average operation time, intraoperative hemorrhage, fracture healing time and excellent and good rates of postoperative knee function between two groups. Positive Varus stress test during operation can be an indication for lateral and medial double-plating fixation of distal femoral fractures.

  18. The effect of HIV on early wound healing in open fractures treated with internal and external fixation.

    PubMed

    Aird, J; Noor, S; Lavy, C; Rollinson, P

    2011-05-01

    There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.

  19. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    PubMed

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  20. Use of monocortical miniplates for the intraoral treatment of mandibular fractures.

    PubMed

    Chiodo, Thomas A; Milles, Maano

    2009-03-01

    Fixation of mandibular fractures using rigid hardware has gained wide acceptance over the past 3 decades. The goal of rigid internal fixation is to allow for fracture healing with limited, or no, time in maxillo-mandibular fixation. There has been significant evolution in plate and screw materials and design over the past 30 years. The term miniplate is used to describe a fracture plate with a screw diameter of 2.0 mm or less. With correct diagnosis and understanding of the forces affecting mandible fractures, miniplates can be applied transorally in various situations, allowing for less invasive treatment with open reduction of mandible fractures. This article describes the use of monocortical miniplates for the intraoral treatment of mandibular fractures.

  1. Rib fractures in trauma patients: does operative fixation improve outcome?

    PubMed

    Majak, Peter; Næss, Pål A

    2016-12-01

    Renewed interest in surgical fixation of rib fractures has emerged. However, conservative treatment is still preferred at most surgical departments. We wanted to evaluate whether operative treatment of rib fractures may benefit severely injured patients. Several studies report a reduction in mechanical ventilation time, ICU length of stay (LOS), hospital LOS, pneumonia, need for tracheostomy, pain and costs in operatively treated patients with multiple rib fractures compared with patients treated nonoperatively. Although patient selection and timing of the operation seem crucial for successful outcome, no consensus exists. Mortality reduction has only been shown in a few studies. Most studies are retrospective cohort and case-control studies. Only four randomized control trials exist. Conservative treatment, consisting of respiratory assistance and pain control, is still the treatment of choice in the vast majority of patients with multiple rib fractures. In selected patients, operative fixation of fractured ribs within 72 h postinjury may lead to better outcome. More randomized control trials are needed to further determine who benefits from surgical fixation of rib fractures.

  2. The Use of Mesh Plates for Difficult Fractures of the Patella.

    PubMed

    Volgas, David; Dreger, Tina K

    2017-03-01

    Patella fractures present some of the more complicated fracture patterns in orthopaedic trauma care. This is partially due to the small size of the fragments but also the articular nature of each fragment. Fixation methods such as cerclage wiring, excision of smaller fragments, and screw fixation of larger fragments all have their own challenges. Our study examined our Level I trauma center's experience with variable angle locked 2.7 mm titanium plates for treatment of comminuted patella fractures or treatment of patellar nonunion. After Institutional Review Board approval, we used billing records to identify 105 patients who had undergone operative management of a displaced patella fracture between January 2011 and December 2015. We reviewed the radiographs of these patients to identify which patients underwent treatment with a mesh plate. We found 16 patients (6 males and 10 females) who had undergone fixation with a mesh plate; mean age was 47 years. Nine patients underwent primary open reduction internal fixation (ORIF) and seven underwent mesh plate fixation for failed ORIF of a patella fracture. The mean visual analog pain score was 2.75 (range, 0-9). The mean range of motion was 1 degree of extension (range, 0-10 degrees) to 110 degrees of flexion (range, 45-135 degrees). All fractures healed. Five patients required hardware removal for pain. This review illustrates the effectiveness of the locking mesh plate in two challenging clinical scenarios: that of patellar nonunion and comminuted fractures that preclude standard fixation methods. Although multiple options exist for patellar fracture fixation, the titanium mesh locking plate can be an effective option for retaining the patella in the setting of comminution. Further comparative studies should be undertaken to determine which method of treatment may be superior in the treatment of these fractures. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.

    PubMed

    Nelson, Joshua D; McIff, Terence E; Moodie, Patrick G; Iverson, Jamey L; Horton, Greg A

    2010-03-01

    Internal fixation of the os calcis is often complicated by prolonged soft tissue management and posterior facet disruption. An ideal calcaneal construct would include minimal hardware prominence, sturdy posterior facet fixation and nominal soft tissue disruption. The purpose of this study was to develop such a construct and provide a biomechanical analysis comparing our technique to a standard internal fixation technique. Twenty fresh-frozen cadaver calcanei were used to create a reproducible Sanders type-IIB calcaneal fracture pattern. One calcaneus of each pair was randomly selected to be fixed using our compressive headless screw technique. The contralateral matched calcaneus was fixed with a nonlocking calcaneal plate in a traditional fashion. Each calcaneus was cyclically loaded at a frequency of 1 Hz for 4000 cycles using an increasing force from 250 N to 1000 N. An Optotrak motion capturing system was used to detect relative motion of the three fracture fragments at eight different points along the fracture lines. Horizontal separation and vertical displacement at the fracture lines was recorded, as well as relative rotation at the primary fracture line. When the data were averaged, there was more horizontal displacement at the primary fracture line of the plate and screw construct compared to the headless screw construct. The headless screw construct also had less vertical displacement at the primary fracture line at every load. On average those fractures fixed with the headless screw technique had less rotation than those fixed with the side plate technique. A new headless screw technique for calcaneus fracture fixation was shown to provide stability as good as, or better than, a standard side plating technique under the axial loading conditions of our model. Although further testing is needed, the stability of the proposed technique is similar to that typically provided by intramedullary fixation. This fixation technique provides a biomechanically stable construct with the potential for a minimally invasive approach and improved post-operative soft tissue healing.

  4. Management of Type II Odontoid Fracture for Osteoporotic Bone Structure: Preliminary Report.

    PubMed

    Cosar, Murat; Ozer, A Fahir; Alkan, Bahadır; Guven, Mustafa; Akman, Tarık; Aras, Adem Bozkurt; Ceylan, Davut; Tokmak, Mehmet

    2015-01-01

    Anterior transodontoid screw fixation technique is generally chosen for the management of type II odontoid fractures. The nonunion of type II odontoid fractures is still a major problem especially in elderly and osteoporotic patients. Eleven osteoporotic type II odontoid fracured patients were presented in this article. We have divided 11 patients in two groups as classical and Ozer's technique. We have also compared (radiologically and clinically) the classical anterior transodontoid screw fixation (group II: 6 cases) and Ozer's transodontoid screw fixation technique (group I: 5 cases) retrospectively. There was no difference regaring the clinical features of the groups. However, the radiological results showed 100% fusion for Ozer's screw fixation technique and 83% fusion for the classical screw fixation technique. In conclusion, we suggest that Ozer's technique may help to increase the fusion capacity for osteoporotic type II odontoid fractures.

  5. Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures.

    PubMed

    Madsen, Wes; Yaseen, Zaneb; LaFrance, Russell; Chen, Tony; Awad, Hani; Maloney, Michael; Voloshin, Ilya

    2013-06-01

    The purpose of this study was to determine the effect of coracoclavicular (CC) fixation on biomechanical stability in type IIB distal clavicle fractures fixed with plate and screws. Twelve fresh-frozen matched cadaveric specimens were used to create type IIB distal clavicle fractures. Dual-energy x-ray absorptiometry (DEXA) scans ensured similar bone quality. Group 1 (6 specimens) was stabilized with a superior precontoured distal clavicle locking plate and supplemental suture anchor CC fixation. Group 2 (6 specimens) followed the same construct without CC fixation. Each specimen was cyclically loaded in the coronal plane at 40 to 80 N for 17,500 cycles. Load-to-failure testing was performed on the specimens that did not fail cyclic loading. Outcome measures included mode of failure and the number of cycles or load required to create 10 mm of displacement in the construct. All specimens (12 of 12) completed cyclic testing without failure and underwent load-to-failure testing. Group 1 specimens failed at a mean of 808.5 N (range, 635.4 to 952.3 N), whereas group 2 specimens failed at a mean of 401.3 N (range, 283.6 to 656.0 N) (P = .005). Group 1 specimens failed by anchor pullout without coracoid fracture (4 of 6) and distal clavicle fracture fragment fragmentation (1 of 6); one specimen did not fail at the maximal load the materials testing machine was capable of exerting (1,000 N). Group 2 specimens failed by distal clavicle fracture fragment fragmentation (3 of 6) and acromioclavicular (AC) joint displacement (1 of 6); 2 specimens did not fail at the maximal load of the materials testing machine. During cyclic loading, type IIB distal clavicle fractures with and without CC fixation remain stable. CC fixation adds stability to type IIB distal clavicle fractures fixed with plate and screws when loaded to failure. CC fixation for distal clavicle fractures is a useful adjunct to plate-and-screw fixation to augment stability of the fracture. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Minimally invasive fixation of type B and C interprosthetic femoral fractures.

    PubMed

    Ehlinger, M; Czekaj, J; Adam, P; Brinkert, D; Ducrot, G; Bonnomet, F

    2013-09-01

    Interprosthetic femoral fractures are rare and raise unresolved treatment issues such as the length of the fixation material that best prevents secondary fractures. Awareness of the advantages of locked-plate fixation via a minimally invasive approach remains limited, despite the potential of this method for improving success rates. Femur-spanning (from the trochanters to the condyles) locked-plate fixation via a minimally invasive approach provides high healing rates with no secondary fractures. From January 2004 to May 2011, all eight patients seen for interprosthetic fractures were treated with minimally invasive locked-plate fixation. Mean time since hip arthroplasty was 47.5 months and mean time since knee arthroplasty was 72.6 months. There were 12 standard primary prostheses and four revision prostheses; 11 prostheses were cemented and a single prosthesis showed femoral loosening. Classification about the hip prostheses was Vancouver B in one patient and Vancouver C in seven patients; about the knee prosthesis, the fracture was SoFCOT B in three patients and SOFCOT C in five patients, and a single fracture was SoFCOT D. Minimally invasive locking-plate fixation was performed in all eight patients, with installation on a traction table in seven patients. Healing was obtained in all eight patients, after a mean of 14 weeks (range, 12-16 weeks). One patient had malalignment with more than 5° of varus. There were no general or infectious complications. One patient died, 32 months after surgery. The mean Parker-Palmer mobility score decreased from 6.2 pre-operatively to 2.5 at last follow-up. Early construct failure after 3 weeks in one patient required surgical revision. There was no change in implant fixation at last follow-up. No secondary fractures were recorded. In patients with type B or C interprosthetic fractures, femur-spanning fixation not only avoids complications related to altered bone stock and presence of prosthetic material, but also decreases the risk of secondary fractures by eliminating stress riser zones. The minimally invasive option enhances healing by preserving the fracture haematoma. Thus, healing was obtained consistently in our patients, with no secondary fractures, although the construct failed in one patient. Level IV. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  7. Arthroscopic Management of Tibial Spine Avulsion Fractures: Principles and Techniques.

    PubMed

    Strauss, Eric J; Kaplan, Daniel James; Weinberg, Maxwell E; Egol, Jonathan; Jazrawi, Laith M

    2018-05-15

    Tibial spine fractures are uncommon injuries affecting the insertion of the anterior cruciate ligament on the tibia. They typically occur in skeletally immature patients aged 8 to 14 years and result from hyperextension of the knee with a valgus or rotational force. Diagnosis is based on history, physical examination, and standard radiographs. The use of MRI can identify entrapped soft tissue that may prevent reduction. Open or arthroscopic repair is indicated in patients with partially displaced fractures (>5 mm) with one third to one half of the avulsed fragment elevated, in patients who have undergone unsuccessful nonsurgical reduction and long leg casting or bracing, and in patients with completely displaced fractures. Arthroscopy offers reduced invasiveness and decreased morbidity. Suture fixation and screw fixation have produced successful results. Suture fixation can eliminate the risk of fracture fragment comminution during screw insertion, the risk of neurovascular injury, and the need for hardware removal. Suture fixation is ideal in cases in which existing comminution prevents screw fixation.

  8. Functional and radiologic outcome of open reduction and internal fixation of condylar head and neck fractures using miniplate or microplate system.

    PubMed

    Xie, Si-Tian; Singhal, Dhruv; Chen, Chien-Tzung; Chen, Yu-Ray

    2013-12-01

    Although the appropriate management of condylar process fractures after miniplate or microplate fixation has been described, there has been no comparative analysis of these plating systems. A retrospective review of patients who underwent open reduction and internal fixation (ORIF) of condylar head or neck fractures at our institution from January 2000 through August 2010 identified 70 patients. Of these, 38 were treated with microplates and 32 with miniplates. The primary functional and radiographic results were the maximal mouth opening and condylar bone resorption, respectively. The rates of complications, including malocclusion, chin deviation, temporomandibular joint complaints, and facial nerve palsy, were recorded. The maximal mouth opening was larger in the microplate group than in the miniplate group throughout the follow-up period; this difference was statistically significant 12 (P = 0.020), 18 (P = 0.026), and 24 (P = 0.032) months after ORIF. Similarly, the radiographic scores for bone resorption and condyle morphology were significantly better in the microplate group than in the miniplate group throughout the follow-up period [6 (P = 0.011), 12 (P = 0.035), 24 (P = 0.026), and 48 (P = 0.040) months after ORIF]. Moreover, patients who underwent miniplate fixation experienced a significantly higher incidence of temporomandibular joint click than those who underwent microplate fixation (P = 0.014). Microplates limit dissection, providing excellent fixation for intracapsular condylar head fractures, and also provide adequate rigidity for fixation of condylar neck fractures. Microplate fixation of condylar head and neck fractures yielded excellent functional and radiographic results. The rates of complications after microplate fixation were equal to or less than those in the miniplate group. Prospective studies are needed to confirm these findings.

  9. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.

    PubMed

    Chen, Fancheng; Huang, Xiaowei; Ya, Yingsun; Ma, Fenfen; Qian, Zhi; Shi, Jifei; Guo, Shuolei; Yu, Baoqing

    2018-01-16

    Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P < 0.0001). The maximal value of displacement (sum) in the IMN system was 8.82 mm, which was lower than that in the DLP fixation system (9.48 mm). This study demonstrated that the stability provided by the locking plate fixation system was superior to the intramedullary nails fixation system and served as an alternative fixation for the extra-articular proximal tibial fractures of young patients.

  10. Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures.

    PubMed

    Chen, Xiaobin; Shannon, Steven F; Torchia, Michael; Schoch, Bradley

    2017-06-01

    The clavicle exhibits considerable movement in three planes making rigid fixation challenging. The addition of a second plate may be considered to improve fixation rigidity, but risks compromising the blood supply to the fracture site. The purpose of this study is to assess if extraperiosteal dual plate fixation increases the rate of non-union, reoperation, and complications at 1 year for surgically treated acute mid-shaft clavicle fractures. Between June 1998 and June 2013, surgically treated mid-shaft clavicle fractures undergoing open reduction internal fixation within 4 weeks of injury were retrospectively reviewed. Patients undergoing single plate fixation were compared to dual plate fixation. Patients were followed for a minimum of 1 year. Charts were reviewed to assess union rates, reoperation, and complications. One hundred and sixty-three clavicles (125 single plates, 34 dual plates) were evaluated. All patients (100%) in dual plating group and one hundred and fourteen (91%) in single plating group obtained bony union by 1 year (p = 0.13). Six patients (4.8%) experienced a non-union in the single plating cohort compared to the dual plating cohort who had a 100% union rate. Seven patients required reoperation in the single plate cohort due to implant failure (N = 4), infection (N = 2), and non-union (N = 1). This limited series of patients demonstrates dual plate fixation is a reliable option for acute mid-shaft clavicle fractures, with excellent union rates and low complication rates. Compared to single plate fixation, no significant differences in outcomes were identified. In the case of more complex fracture patterns, application of a second extraperiosteal plate may be utilized without compromising healing or increasing complication rates.

  11. Modified preauricular approach and rigid internal fixation for intracapsular condyle fracture of the mandible.

    PubMed

    He, Dongmei; Yang, Chi; Chen, Minjie; Bin, Jiang; Zhang, Xiaohu; Qiu, Yating

    2010-07-01

    This article reports a modified preauricular approach for intracapsular condyle fracture (ICF) of the mandible and evaluates the stability of various internal fixation methods in the temporomandibular joint (TMJ) division of the Shanghai Ninth People's Hospital. One hundred fifty-one patients with 208 ICFs diagnosed by panoramic radiograph and computed tomographic (CT) scan received open treatment in the TMJ division from 1999 to 2008. Their charts were reviewed. Classification of the fracture was based on coronal CT scan. Forty-three patients also underwent magnetic resonance imaging before the operation to check displacement of the disc. A modified preauricular approach was used for all patients. Various internal fixation methods from wire, to screw, to plate were evaluated for stability. There were 110 ICFs of type A fracture, 60 of type B fracture, 9 of type C fracture, 25 of type M fracture, and 4 fractures without displacement. A modified preauricular approach was used for open treatment, which can better expose and protect the TMJ and superficial temporal vessels. Wire and plate is the commonly used stable fixation method for type A, B, and M fractures, which accounted for 56.7% (101/178). Small fracture fragments were removed with disc repositioning for all type C fractures (n = 9) and some type B (n = 9) and M fractures (n = 5). Three type M fracture and 3 nondisplaced ICFs were treated closed. Eighty-nine patients with 115 ICFs had postoperative CT scan, which showed anatomic and nearly anatomic fracture reduction rates of 95.6%. Thirty-five patients with 44 ICFs had long-term follow-ups from 3 months to 5 years. Among them, 63.2% (n = 12/19) pediatric ICFs had continuous condyle growth after open reduction and rigid fixation; 92% adults had ICFs that healed well (n = 23/25). Postoperative complications were facial nerve injury (n = 3), TMJ clicking (n = 1), and condyle resorption that required plate removal (n = 4). A modified preauricular approach provides better exposure and protection of the TMJ and superficial temporal vessels. Wire and plate provides stable fixation for type A and some type B and M fractures. Open reduction and rigid fixation produce good results for adult patients. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. [Effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation].

    PubMed

    Ge, Qihang; Wan, Chunyou; Liu, Yabei; Ji, Xu; Ma, Jihai; Cao, Haikun; Yong, Wei; Liu, Zhao; Zhang, Ningning

    2017-08-01

    To investigate the effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation. The data of 45 cases with tibial and fibular open fractures treated by Taylor space stent fixation who meet the selection criteria between January 2015 and June 2016 were retrospectively analysed. The patients were divided into trial group (23 cases) and control group (22 cases) according to whether the axial stress stimulation was performed after operation. There was no significant difference in gender, age, affected side, cause of injury, type of fracture, and interval time from injury to operation between 2 groups ( P >0.05). The axial stress stimulation was performed in trial group after operation. The axial load sharing ratio was tested, and when the value was less than 10%, the external fixator was removed. The fracture healing time, full weight-bearing time, and external fixator removal time were recorded and compared. After 6 months of external fixator removal, the function of the limb was assessed by Johner-Wruhs criteria for evaluation of final effectiveness of treatment of tibial shaft fractures. There were 2 and 3 cases of needle foreign body reaction in trial group and control group, respectively, and healed after symptomatic anti allergic treatment. All the patients were followed up 8-12 months with an average of 10 months. All the fractures reached clinical healing, no complication such as delayed union, nonunion, or osteomyelitis occurred. The fracture healing time, full weight-bearing time, and external fixator removal time in trial group were significantly shorter than those in control group ( P <0.05). After 6 months of external fixator removal, the function of the limb was excellent in 13 cases, good in 6 cases, fair in 3 cases, and poor in 1 case in trial group, with an excellent and good rate of 82.6%; and was excellent in 5 cases, good in 10 cases, fair in 4 cases, and poor in 3 cases in control group, with an excellent and good rate of 68.2%, showing significant difference between 2 groups ( Z =-2.146, P =0.032). The axial stress stimulation of Taylor space stent fixation can promote the healing of tibial and fibular open fractures and promote local bone formation at fracture site.

  13. Biomechanical investigation of different surgical strategies for the treatment of rib fractures using a three-dimensional human respiratory model.

    PubMed

    Shih, Kao-Shang; Truong, Thanh An; Hsu, Ching-Chi; Hou, Sheng-Mou

    2017-11-02

    Rib fracture is a common injury and can result in pain during respiration. Conservative treatment of rib fracture is applied via mechanical ventilation. However, ventilator-associated complications frequently occur. Surgical fixation is another approach to treat rib fractures. Unfortunately, this surgical treatment is still not completely defined. Past studies have evaluated the biomechanics of the rib cage during respiration using a finite element method, but only intact conditions were modelled. Thus, the purpose of this study was to develop a realistic numerical model of the human rib cage and to analyse the biomechanical performance of intact, injured and treated rib cages. Three-dimensional finite element models of the human rib cage were developed. Respiratory movement of the human rib cage was simulated to evaluate the strengths and limitations of different scenarios. The results show that a realistic human respiratory movement can be simulated and the predicted results were closely related to previous study (correlation coefficient>0.92). Fixation of two fractured ribs significantly decreased the fixation index (191%) compared to the injured model. This fixation may provide adequate fixation stability as well as reveal lower bone stress and implant stress compared with the fixation of three or more fractured ribs.

  14. Iliac screw for reconstructing posterior pelvic ring in Tile type C1 pelvic fractures.

    PubMed

    Li, Yonggang; Sang, Xiguang; Wang, Zhiyong; Cheng, Lin; Liu, Hao; Qin, Tao; Di, Kai

    2018-06-18

    It is often difficult to achieve stable fixation in Tile type C1 pelvic fractures and there is no standard fixation technique for these types of injuries. Iliac screw fixation can be used for treating Type C1 pelvic fractures. A retrospective review was performed on 47 patients who underwent iliac screw fixation in posterior column of ilium (PCI) for Tile type C1 pelvic fractures from July 2007 to December 2014. All patients were treated with fracture reduction, sacral nerve root decompression (if needed), internal fixation by iliac screw and connecting rod. The data on surgical time, intraoperative bleeding volume, postoperative neurologic functions and postoperative complications were analyzed. Patients were follow-up for at least 12months. The mean surgical time was 148minutes, and the mean intraoperative bleeding volume was 763ml. Patients were encouraged in-bed activities immediately after surgery. The postoperative Majeed functional score was 48-100 points (mean 80.2), corresponding to an excellent and good recovery of 91.5%. Postoperative X-radiographs and CT scans indicated satisfactory fracture reduction. Iliac screw fixation combined with sacral nerve canal decompression could effectively restore pelvic alignment and improve neurological functions for complex pelvic trauma. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  15. When and how to operate the posterior malleolus fragment in trimalleolar fractures: a systematic literature review.

    PubMed

    Verhage, Samuel Marinus; Hoogendoorn, Jochem Maarten; Krijnen, Pieta; Schipper, Inger Birgitta

    2018-05-12

    Whether or not and how to fixate the posterior malleolus fracture seems to depend on the fracture fragment size and its amount of dislocation, but clear guidelines for daily practice are lacking. In this review, we summarize the literature on preferred treatment of the posterior fragment in trimalleolar fractures. A systematic review of publications between January 1995 and April 30 2017 on this topic in the PubMed, Embase, and Cochrane databases was performed according to the PRISMA statement. Seventeen (2 prospective and 15 retrospective) of the 180 identified studies were included. Six studies report on indications for fixation of posterior malleolus fracture fragments. Eleven studies compare different fixation approaches and techniques for the posterior fragment. Meta-analysis was not possible due to varying fixation criteria and outcomes. There was no clear association between posterior fragment size and functional outcome or development of osteoarthritis. The non-anatomical reduction of the fragment was of more influence on outcome. Radiological and functional outcome was better after open reduction and internal fixation via the posterolateral approach than after percutaneous anterior-to-posterior screw fixation. The posterior fragment size is not a clear indication for its fixation. A step-off, however, seems an important indicator for developing posttraumatic osteoarthritis and worse functional outcome. Posterior fragments involving the intra-articular surface need to be reduced and fixated to prevent postoperative persisting step-off. Furthermore, fixation of the posterior malleolus via an open posterolateral approach seems superior to percutaneous anterior-to-posterior fixation. However, these results need to be confirmed in a prospective comparative trial. Therapeutic level II.

  16. Arthroscopic fixation of the clavicle shaft fracture.

    PubMed

    Kim, Yang-Soo; Lee, Hyo-Jin; Kim, Jong-Ick; Yang, Hyo; Jin, Hong-Ki; Patel, Hiren Kirtibhai; Kim, Jong-Ho; Park, In

    2017-01-01

    This article describes an arthroscopic technique for the fixation of clavicle shaft fractures. A viewing portal is made 2 cm anterior to the fracture site, and a working portal is made 2 cm lateral to the fracture site. The guide wire for a 4.0-mm cannulated screw is inserted through the fracture site to the medial fracture fragment under arthroscopic guidance. Through the medial fragment, the guide wire is delivered through the skin anteriorly. The fracture is reduced, and then, the guide wire is drilled back across the fracture site to the lateral fracture fragment. After confirming the reduction under arthroscopy, the appropriately sized cannulated screw is inserted after reaming. This arthroscopic technique would be useful for the precise reduction and minimal invasive fixation of clavicle shaft fractures. Preliminary results are encouraging, and further studies with long-term follow-up are needed to determine the precise indications and limitations of the procedure.

  17. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    PubMed

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  18. A comparison of three different surgical procedures in the treatment of type A thoracolumbar fractures: a randomized controlled trial.

    PubMed

    Lyu, Jianhua; Chen, Kai; Tang, Zhaohui; Chen, Yu; Li, Ming; Zhang, Qiulin

    2016-06-01

    The aim of the study was to evaluate the efficacy of three different surgical procedures in the treatment of type A thoracolumbar fractures. Between September 2012 and January 2015, a total of 90 patients with type A thoracolumbar fractures were randomly assigned into three groups of 30 each. Patients in group A, B, and C were treated with three-level percutaneous fixation, two-level percutaneous fixation, and three-level open fixation, respectively. Blood loss, duration of surgery, VAS scores, Cobb angles, and anterior height ratios of fractured vertebrae were collected for statistical analysis. The average follow-up was 17.7 months. Post-operative Cobb angles were significantly corrected and anterior height ratios of fractured vertebrae were well restored in all three groups (p < 0.01). Back pain was efficiently relieved according to VAS score change (p < 0.01). There were significant differences in values of blood loss and post-operative VAS scores (at three months) between group A and group C (p < 0.01). No significant difference concerning post-operative anterior height ratios of fractured vertebrae, Cobb angles and correction losses was observed between group A and group B (p = 0.580, 0.840, 0.215, respectively). Percutaneous fixation not only provides the same reduction effect as open fixation, but also has an advantage of causing less operation related trauma which is beneficial to post-operative rehabilitation. The efficacy of three-level percutaneous fixation and two-level percutaneous fixation in the treatment of type A thoracolumbar fractures is not significantly different.

  19. Distal radius fractures and the volar lunate facet fragment: Kirschner wire fixation in addition to volar-locked plating.

    PubMed

    Moore, Amy M; Dennison, David G

    2014-06-01

    The volar lunate facet fragment of a distal radius fracture may not be stabilized with volar-locked plating alone due to the small size and distal location of the fragment. Identification and stabilization of this small fragment is critical as unstable fixation may result in radiocarpal and radioulnar joint subluxation. The addition of spring wire fixation with volar plating can provide stable internal fixation of this critical fracture fragment. A retrospective review (2006-2011) identified nine patients with distal radius fractures with an associated volar lunate facet fragment that were treated with volar-locked plating and spring wire fixation of the volar lunate facet fragment. Radiographic indices, range of motion, grip strength, and postoperative Patient-related wrist evaluation (PRWE) scores were obtained to assess pain and function. All distal radius fractures healed, and the volar lunate facet fragment reduction was maintained. The mean follow-up was 54 weeks. Mean active range of motion was 46° wrist flexion, 51° wrist extension, 80° pronation, and 68° supination. The mean grip strength was 21 Kg, achieving 66 % of the uninjured limb. The average PRWE score was 17. No patient required removal of hardware or had evidence of tendon irritation. The addition of spring wire fixation to volar-locked plating provided stable fixation of the volar lunate facet fragment of distal radius fractures without complication. This technique addresses a limitation of volar-locked plating to control the small volar lunate facet fragment in distal radius fractures otherwise amenable to volar plating. A retrospective case series, Level IV.

  20. Biomechanical Strength of Retrograde Fixation in Proximal Third Scaphoid Fractures.

    PubMed

    Daly, Charles A; Boden, Allison L; Hutton, William C; Gottschalk, Michael B

    2018-04-01

    Current techniques for fixation of proximal pole scaphoid fractures utilize antegrade fixation via a dorsal approach endangering the delicate vascular supply of the dorsal scaphoid. Volar and dorsal approaches demonstrate equivalent clinical outcomes in scaphoid wrist fractures, but no study has evaluated the biomechanical strength for fractures of the proximal pole. This study compares biomechanical strength of antegrade and retrograde fixation for fractures of the proximal pole of the scaphoid. A simulated proximal pole scaphoid fracture was produced in 22 matched cadaveric scaphoids, which were then assigned randomly to either antegrade or retrograde fixation with a cannulated headless compression screw. Cyclic loading and load to failure testing were performed and screw length, number of cycles, and maximum load sustained were recorded. There were no significant differences in average screw length (25.5 mm vs 25.6 mm, P = .934), average number of cyclic loading cycles (3738 vs 3847, P = .552), average load to failure (348 N vs 371 N, P = .357), and number of catastrophic failures observed between the antegrade and retrograde fixation groups (3 in each). Practical equivalence between the 2 groups was calculated and the 2 groups were demonstrated to be practically equivalent (upper threshold P = .010). For this model of proximal pole scaphoid wrist fractures, antegrade and retrograde screw configuration have been proven to be equivalent in terms of biomechanical strength. With further clinical study, we hope surgeons will be able to make their decision for fixation technique based on approaches to bone grafting, concern for tenuous blood supply, and surgeon preference without fear of poor biomechanical properties.

  1. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    PubMed

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  2. Transosseous fixation of pediatric displaced mandibular fractures with polyglactin resorbable suture--a simplified technique.

    PubMed

    Chandan, Sanjay; Halli, Rajshekhar; Joshi, Samir; Chhabaria, Gaurav; Setiya, Sneha

    2013-11-01

    Management of pediatric mandibular fractures presents a unique challenge to surgeons in terms of its numerous variations compared to adults. Both conservative and open methods have been advocated with their obvious limitations and complications. However, conservative modalities may not be possible in grossly displaced fractures, which necessitate the open method of fixation. We present a novel and simplified technique of transosseous fixation of displaced pediatric mandibular fractures with polyglactin resorbable suture, which provides adequate stability without any interference with tooth buds and which is easy to master.

  3. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    PubMed

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  4. Potential Benefits of Rib Fracture Fixation in Patients with Flail Chest and Multiple Non-flail Rib Fractures.

    PubMed

    Qiu, Meiguang; Shi, Zhanjun; Xiao, Jun; Zhang, Xuming; Ling, Shishui; Ling, Hao

    2016-12-01

    The purpose of this study is to evaluate the potential benefits of rib fracture fixation in patients with flail chest and multiple non-flail rib fractures versus conventional treatment modalities. A retrospective reviewed study compared 86 cases which received surgical treatment between June 2009 and May 2013 to 76 cases which received conservative treatment between January 2006 and May 2009. The patients were divided into the flail chest ( n  = 38) and multiple non-flail rib fracture groups ( n  = 124). In the flail chest group, the mechanical ventilation time, ICU monitoring time, tracheostomies, thoracic deformity, and impaired pulmonary function and return to full-time employment were compared. In the multiple non-flail rib fracture group, fracture healing, visual analog scale (VAS) pain score, inpatient length of stay, atelectatic, pulmonary complications, and normal activity-returning time were compared. Patients in the flail chest operative fixation group had significantly shorter ICU stay, decreased ventilator requirements, fewer tracheostomies, less thoracic deformity and impaired pulmonary function, and more returned to full-time employment. Patients in the multiple non-flail rib fracture operative fixation had shorter hospital stay, less pain, earlier return to normal activity, more fracture healing, less atelectasis, and fewer pulmonary infections. This study demonstrates the potential benefits of surgical stabilization of flail chest and multiple non-flail rib fractures with plate fixation. When compared with conventional conservative management, operatively managed patients demonstrated improved clinical outcomes.

  5. Biomechanical characteristics of fixation methods for floating pubic symphysis.

    PubMed

    Song, Wenhao; Zhou, Dongsheng; He, Yu

    2017-03-07

    Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.

  6. Haptic computer-assisted patient-specific preoperative planning for orthopedic fractures surgery.

    PubMed

    Kovler, I; Joskowicz, L; Weil, Y A; Khoury, A; Kronman, A; Mosheiff, R; Liebergall, M; Salavarrieta, J

    2015-10-01

    The aim of orthopedic trauma surgery is to restore the anatomy and function of displaced bone fragments to support osteosynthesis. For complex cases, including pelvic bone and multi-fragment femoral neck and distal radius fractures, preoperative planning with a CT scan is indicated. The planning consists of (1) fracture reduction-determining the locations and anatomical sites of origin of the fractured bone fragments and (2) fracture fixation-selecting and placing fixation screws and plates. The current bone fragment manipulation, hardware selection, and positioning processes based on 2D slices and a computer mouse are time-consuming and require a technician. We present a novel 3D haptic-based system for patient-specific preoperative planning of orthopedic fracture surgery based on CT scans. The system provides the surgeon with an interactive, intuitive, and comprehensive, planning tool that supports fracture reduction and fixation. Its unique features include: (1) two-hand haptic manipulation of 3D bone fragments and fixation hardware models; (2) 3D stereoscopic visualization and multiple viewing modes; (3) ligaments and pivot motion constraints to facilitate fracture reduction; (4) semiautomatic and automatic fracture reduction modes; and (5) interactive custom fixation plate creation to fit the bone morphology. We evaluate our system with two experimental studies: (1) accuracy and repeatability of manual fracture reduction and (2) accuracy of our automatic virtual bone fracture reduction method. The surgeons achieved a mean accuracy of less than 1 mm for the manual reduction and 1.8 mm (std [Formula: see text] 1.1 mm) for the automatic reduction. 3D haptic-based patient-specific preoperative planning of orthopedic fracture surgery from CT scans is useful and accurate and may have significant advantages for evaluating and planning complex fractures surgery.

  7. Open Reduction in Pediatric Condylar Fracture.

    PubMed

    Barbosa, Alexandre Agostini; Mariano, Ronaldo Célio

    2017-05-01

    Facial fractures in children are rare. Lack of pneumatization, fat pockets, mixed dentition, contribute to the elasticity and bone stability. When mandibular fractures occur in children, most often involve the condyle by indirect trauma. Such fractures are the center of discussion on the form of treatment if this should be performed conservatively, or held the reduction and fixation of the fracture with surgical exposure of the fragments. In condylar fractures in children, in most patients, the proposed treatment is closed reduction. Treatment with open reduction and fixation has its specific indications. In this case, the authors report a patient cycling accident victim, with cut-contusion injury in ment with limited mouth opening and left condylar fracture with medial rotation. The treatment was the reduction and fixation of fragments by open process.

  8. External fixation for severe open fractures of the humerus caused by missiles.

    PubMed

    Zinman, C; Norman, D; Hamoud, K; Reis, N D

    1997-10-01

    To evaluate the use of external fixation of the humerus after missile injuries. Retrospective. University medical center. Twenty-six soldiers with twenty-six open Gustilo type III fractures. Immediate external fixation. Clinical, functional, social, and rehabilitation criteria were evaluated. Excellent in fourteen patients (61%), good in four (17%), fair in three (13%), and poor in two (9%). All fractures eventually healed. External fixation is the preferred initial treatment for stabilizing severe open missile fractures of the humerus. Its use, together with radical debridement of dead bone, has reduced the incidence of chronic infection and improved the prognosis of vascular repairs. As a result, the rate of morbidity and upper limb amputation has been reduced significantly, compared with our previous experience.

  9. Delayed fixation of displaced bilateral, atraumatic, femoral neck fractures in a patient with pregnancy related osteomalacia.

    PubMed

    Docker, Charles; Starks, Ian; Wade, Roger; Wynn-Jones, Charles

    2011-06-01

    We present the case of a woman diagnosed with simultaneous displaced intracapsular femoral neck fractures following the birth of her second child. No traumatic event was identified. Diagnosis was delayed as the cause of her pain was thought to be non-skeletal in origin. Radiological and serological investigations were diagnostic of osteomalacia. Surgical fixation of her fractures was further delayed due to profound hypocalcaemia. Despite the delays, fixation with bilateral dynamic hip screws resulted in union with no evidence of avascular necrosis at 2 years follow-up. We believe this to be the first report of atraumatic bilateral femoral neck fractures and it shows that a good result can be achieved even in the presence of delayed fixation.

  10. Stress analysis of implant-bone fixation at different fracture angle

    NASA Astrophysics Data System (ADS)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  11. Technical tip: tightrope fixation of neer type II distal clavicle fracture supported by a case series.

    PubMed

    Haque, Syed; Khan, Anwar; Sharma, A; Sundararajan, Sabapathy

    2014-03-27

    We present a case series of 3 patients who underwent a novel technique of tight rope fixation for Neer type II distal clavicle fracture. 2-3 cm incision was made lateral to the fracture site moving inferomedially. Part of the distal end of clavicle was exposed close to fracture site and further dissection was carried out to reveal the coracoid process. Tight rope fixation of the distal ends of clavicle and coracoid was performed to achieve satisfactory fracture reduction on x-ray. 4 weeks of sling with gentle pendulum movement were followed by active shoulder movement exercises. Radiographic union was reached at 6 weeks' time, while the patients achieved proper shoulder functionality 3 months following the operation. Neer type II distal clavicle fractures are characterized by disruption of the coracoclavicular ligament with wide proximal fragment displacement. Overall, type II distal clavicle fractures have a 20-30% nonunion rate if treated non-surgically. Various techniques have been described for the treatment of these fractures, including hook plate and nailing. Tight rope fixation provides proper apposition of the fracture fragments for union by maintaining a reduced coracoclavicular interval.

  12. The lingual splint: an often forgotten method for fixating pediatric mandibular fractures.

    PubMed

    Binahmed, Abdulaziz; Sansalone, Claudio; Garbedian, Justin; Sándor, George K B

    2007-01-01

    Maxillofacial fractures are uncommon in the pediatric population, and their treatment is unique due to the psychological, physiological, developmental and anatomical characteristics of children. We present the case of a boy who was treated in an outpatient dental clinic using a lingual splint for the reduction, stabilization and fixation of a mandibular body fracture. This technique is a reliable, noninvasive procedure that dentists may consider in selected cases by referral to an oral and maxillofacial surgeon. It also limits the discomfort and morbidity that can be associated with maxillomandibular fixation or open reduction and internal fixation in pediatric patients.

  13. A clinical evaluation of alternative fixation techniques for medial malleolus fractures.

    PubMed

    Barnes, Hayley; Cannada, Lisa K; Watson, J Tracy

    2014-09-01

    Medial malleolus fractures have traditionally been managed using partially threaded screws and/or Kirschner wire fixation. Using these conventional techniques, a non-union rate of as high as 20% has been reported. In addition too many patients complaining of prominent hardware as a source of pain post-fixation. This study was designed to assess the outcomes of medial malleolar fixation using a headless compression screw in terms of union rate, the need for hardware removal, and pain over the hardware site. Saint Louis University and Mercy Medical Center, Level 1 Trauma Centers, St. Louis, MO. After IRB approval, we used billing records to identify all patients with ankle fractures involving the medial malleolus. Medical records and radiographs were reviewed to identify patients with medial malleolar fractures treated with headless compression screw fixation. Our inclusion criteria included follow-up until full weight bearing and a healed fracture. Follow-up clinical records and radiographs were reviewed to determine union, complication rate and perception of pain over the site of medial malleolus fixation. Sixty-four ankles were fixed via headless compression screws and 44 had adequate follow-up for additional evaluation. Seven patients had isolated medial malleolar fractures, 23 patients had bimalleolar fractures, and 14 patients had trimalleolar fractures. One patient (2%) required hardware removal due to cellulitis. One patient (2%) had a delayed union, which healed without additional intervention. Ten patients (23%) reported mild discomfort to palpation over the medial malleolus. The median follow-up was 35 weeks (range: 12-208 weeks). There were no screw removals for painful hardware and no cases of non-union. Headless compression screws provide effective compression of medial malleolus fractures and result in good clinical outcomes. The headless compression screw is a beneficial alternative to the conventional methods of medial malleolus fixation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study.

    PubMed

    Sobhan, Mohammad R; Abrisham, Seyed Mohammad J; Vakili, Mahmood; Shirdel, Saeed

    2016-10-01

    Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient's quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations. Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT) scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed's score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described. The injury was unilateral in 11 (78.5%) patients and bilateral in 3 (21.5%). Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4%) and 1 (7.1%) cases, respectively. In this study most patients (85%) return to work postoperatively. According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.

  15. Metacarpal Neck Fractures: A Review of Surgical Indications and Techniques

    PubMed Central

    Padegimas, Eric M.; Warrender, William J.; Jones, Christopher M.; Ilyas, Asif M.

    2016-01-01

    Context Hand injuries are a common emergency department presentation. Metacarpal fractures account for 40% of all hand fractures and can be seen in the setting of low or high energy trauma. The most common injury pattern is a metacarpal neck fracture. In this study, the authors aim to review the surgical indications for metacarpal neck fractures, the fixation options available along with the risk and benefits of each. Evidence Acquisition Literature review of the different treatment modalities for metacarpal neck fractures. Review focuses on surgical indications and the risks and benefits of different operative techniques. Results The indications for surgery are based on the amount of dorsal angulation of the distal fragment. The ulnar digits can tolerate greater angulation as the radial digits more easily lose grip strength. The most widely utilized fixation techniques are pinning with k-wires, dorsal plating, or intramedullary fixation. There is currently no consensus on an optimal fixation technique as surgical management has been found to have a complication rate up to 36%. Plate and screw fixation demonstrated especially high complication rates. Conclusions Metacarpal neck fractures are a common injury in young and active patients that results in substantial missed time from work. While the surgical indications are well-described, there is no consensus on the optimal treatment modality because of high complication rates. Dorsal plating has higher complication rates than closed reduction and percutaneous pinning, but is necessary in comminuted fractures. The lack of an ideal fixation construct suggests that further study of the commonly utilized techniques as well as novel techniques is necessary. PMID:27800460

  16. The operative outcomes of displaced medial-end clavicle fractures.

    PubMed

    Sidhu, Verinder S; Hermans, Deborah; Duckworth, David G

    2015-11-01

    Nonoperative treatment of displaced medial clavicle fractures often leads to poor functional outcomes and painful nonunions. This study investigates the functional outcomes of patients undergoing operative fixation of these fractures. We investigated 27 patients undergoing operative fixation of a medial clavicle fracture; 24 had an acute, displaced fracture and 3 had fixation for nonunions. Preoperative radiographs or computed tomography scans were obtained, and data collected included age, sex, mechanism of injury, and fixation method. Follow-up included physical examination and radiographs for assessment of union; Disabilities of the Arm, Shoulder, and Hand scores at 12 months; and the recording of complications. The median age was 37 years (interquartile range, 17-47 years). There were 26 male patients and one female patient included, with 7 physeal injuries and 20 adult injuries. The most common mechanism of fracture was vehicular accident (n = 15). Three patients had operations for nonunions and 2 for a periprosthetic fracture medial to an existing plate. The fracture was fixed with plate and screws in 19 cases and with transosseous sutures in 8 cases. The median Disabilities of the Arm, Shoulder, and Hand score at 12 months was 0.4 (interquartile range, 0-5.0), with a union rate of 100% at 12 months. All patients had full shoulder range of motion at final follow-up and were able to return to preinjury occupational activities. There were no significant complications. Operative fixation of displaced medial clavicle fractures results in anatomic reconstruction and excellent functional outcomes, even in the setting of fixation performed for symptomatic nonunion. Early intervention can minimize the risk of painful nonunion. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  17. Review of techniques for monitoring the healing fracture of bones for implementation in an internally fixated pelvis.

    PubMed

    Wong, Lydia Chwang Yuh; Chiu, Wing Kong; Russ, Matthias; Liew, Susan

    2012-03-01

    Sacral fractures from high-impact trauma often cause instability in the pelvic ring structure. Treatment is by internal fixation which clamps the fractured edges together to promote healing. Healing could take up to 12 weeks whereby patients are bedridden to avoid hindrances to the fracture from movement or weight bearing activities. Immobility can lead to muscle degradation and longer periods of rehabilitation. The ability to determine the time at which the fracture is stable enough to allow partial weight-bearing is important to reduce hospitalisation time. This review looks into different techniques used for monitoring the fracture healing of bones which could lead to possible methods for in situ and non-invasive assessment of healing fracture in a fixated pelvis. Traditional techniques being used include radiology and CT scans but were found to be unreliable at times and very subjective in addition to being non in situ. Strain gauges have proven to be very effective for accurate assessment of fracture healing as well as stability for long bones with external fixators but may not be suitable for an internally fixated pelvis. Ultrasound provides in situ monitoring of stiffness recovery but only assesses local fracture sites close to the skin surface and has only been tested on long bones. Vibration analysis can detect non-uniform healing due to its assessment of the overall structure but may suffer from low signal-to-noise ratio due to damping. Impedance techniques have been used to assess properties of non-long bones but recent studies have only been conducted on non-biological materials and more research needs to be done before it can be applicable for monitoring healing in the fixated pelvis. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. [TREATMENT OF PRONATION EXTERNAL ROTATION ANKLE FRACTURE COMBINED WITH SEPARATION OF DISTAL TIBIOFIBULAR SYNDESMOSIS].

    PubMed

    Wu, Benwen; Ding, Zhenqi; Huang, Guofeng; Liu, Guojun; Cai, Zhemin; Ding, Luobin; Li, Xiang

    2016-09-08

    To evaluate the difference between using and not using syndesmotic screw to treat pronation external rotation (PER) ankle fracture combined with separation of distal tibiofibular syndesmosis. Between April 2011 and October 2014, 46 cases of PER ankle fracture combined with separation of distal tibiofibular syndesmosis were treated, and syndesmotic screw was used in 24 cases (fixation group) and syndesmotic screw was not used in 22 cases (non-fixation group). There was no significant difference in gender, age, weight, cause of injury, side, injury to operation time, and fracture type between 2 groups ( P >0.05). The time for full weight-bearing, fracture healing time, and complications were recorded after operation. Anteroposterior and lateral X-ray films were taken to measure the tibiofibular overlap (TBOL) and tibiofibular clear space (TBCS). Baird-Jackson score was used to evaluate functional recovery of the ankle. All incision healed by first intention without complications. The cases were followed up 13-18 months (mean, 15.2 months) in 2 groups. The time for full weight-bearing was 8-12 weeks (median, 11 weeks) in fixation group, which was significantly later than that in non-fixation group (range, 6-10 weeks; median, 8 weeks) ( Z =-5.049, P =0.000). X-ray examination showed reduction of separation of distal tibiofibular syndesmosis. All fractures healed. The fracture healing time was (13.83±1.37) weeks in fixation group, and was (13.91±1.31) weeks in non-fixation group, showing no significant difference ( t =-0.191, P =0.945). No separation of distal tibiofibular syndesmosis, delayed union, nonunion, loosening, or breakage of fixation devices was observed in 2 groups. There was no significant difference in TBOL, TBCS, Baird-Jackson score and the excellent and good rate between 2 groups ( P >0.05). If the medial, lateral, and posterior structures of the ankle could be repaired according to injury, no significant influence on functional outcome of ankle or radiologic findings could be detected whether syndesmotic fixation is given or not in treating PER ankle fracture (exclude Maisonneuve fracture) combined with separation of distal tibiofibular syndesmosis.

  19. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures.

    PubMed

    Ni, Ming; Niu, Wenxin; Wong, Duo Wai-Chi; Zeng, Wei; Mei, Jiong; Zhang, Ming

    2016-08-01

    Both plate and intramedullary nail fixations, including straight and anatomic nails, have been clinically adopted for the treatment of displaced mid-shaft clavicle fractures. However, the biomechanical performances of these fixations and implants have not been well evaluated. This study aims to compare the construct stability, stress distribution and fracture micro-motion of three fixations based on finite element (FE) method. The FE model of clavicle was reconstructed from CT images of a male volunteer. A mid-shaft fracture gap was created in the intact clavicle. Three fixation styles were simulated including locking plate (LP), anatomic intramedullary nail (CRx), and straight intramedullary nail (RCP). Two loading scenarios (axial compression and inferior bending) were applied at the distal end of the clavicle to simulate arm abduction, while the sternal end was fixed. Under both conditions, the LP was the stiffest, followed by the CRx, and the RCP was the weakest. LP also displayed a more evenly stress distribution for both implant and bone. RCP had a higher stress compared with CRx in both conditions. Moreover, all implants sustained higher stress level under the loading condition of bending than compression. The plate fixation significantly stabilizes the fracture gap, reduces the implant stress, and serves as the recommended fixation for the mid-shaft clavicle fracture. The CRx is an alternative device to treat clavicle shaft fracture, but the shoulder excessive activities should be avoided after operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Modified tension band wiring fixation for avulsion fractures of the calcaneus in osteoporotic bone: a review of three patients.

    PubMed

    Nagura, Issei; Fujioka, Hiroyuki; Kurosaka, Masahiro; Mori, Hiroyuki; Mitani, Makoto; Ozaki, Akihiro; Fujii, Hideo; Nabeshima, Yuji

    2012-01-01

    Calcaneal avulsion fractures are not uncommon, and they are probably more likely in patients with osteoporosis. Closed manipulation for this type of fracture often fails to achieve acceptable reduction, and open reduction and internal fixation are usually required. However, open reduction and internal fixation with either a lag screw or Steinmann pins do not provide satisfactory fixation in patients with diabetes and elderly patients because of the presence of porotic bone. Levi described a tension band fixation system used to treat a calcaneal avulsion fracture using a simple technique performed with a transverse Kirschner wire through the os calcaneus, securing a figure-of-8 metal tension band wiring to the fragment. We report the successful treatment of 3 patients with calcaneal avulsion fractures using a modified tension band wiring technique, resulting in satisfactory recovery. Re-displacement of the fragment during the initial follow-up period was not reported, and bony union was achieved in all patients. We believe this technique is a useful surgical option for the treatment of calcaneal avulsion fractures. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. [Treatment of conmminuted patellar fractures with internal Ni-Ti patellar concentrator and tension bind wire fixation].

    PubMed

    Tan, Hong-lie; Qian, Chen; Zhao, Jin-kun; Shi, Yan; Zhou, Qi

    2009-02-01

    To study the clinical efficacy of the treatment of comminuted patellar fractures with internal NiTi-Patellar concentrator and tension bind wire fixation. From March 2004 to June 2007, 38 cases of fresh comminuted patellar fractures were treated with internal NiTi-Patellar concentrator and tension bind wire fixation. There were 25 males and 13 females,ranging from 21 to 64 years (mean 42.5 years). All were comminuted fractures with displacement, 16 cases were 3 fragments, 14 cases were 4 fragments, 8 cases were 5 fragments. There were other fractures in 8 cases. During followed-up, knee function and complications were evaluated. All patients were followed up for 8 to 24 months (mean 15 months) and obtained complete bone union. No case of implant was loosening and fragment displacement, traumatic arthritis occured in 2 cases. Under Lysholm & Gillquist score, the results were excellent in 17 cases, good in 19, fair in 2. Internal Ni-Ti-Patellar concentrator and tension bind wire fixation is one of the ideal methods for the treatment of comminuted patellar fracture, which could provide satisfied reduction, reliable fixation and good functional recovery.

  2. Necrotizing fasciitis after internal fixation of fracture of femoral trochanteric☆☆☆

    PubMed Central

    Santos, Leandro Emílio Nascimento; Pires, Robinson Esteves Santos; Figueiredo, Leonardo Brandão; Soares, Eduardo Augusto Marques

    2014-01-01

    Necrotizing fasciitis is a rare and potentially lethal soft tissue infection. We report a case of trochanteric femur fracture in a patient who underwent fracture fixation and developed necrotizing fasciitis. A literature review on the topic will be addressed. PMID:26229777

  3. One size does not fit all: distal radioulnar joint dysfunction after volar locking plate fixation.

    PubMed

    Jones, Christopher W; Lawson, Richard D

    2014-02-01

    Background Fractures of the distal radius are among the most common injuries treated by orthopedic surgeons worldwide. Failure to restore distal radius alignment can lead to fracture malunion and poor clinical outcomes, including distal radioulnar joint (DRUJ) instability and limitation of motion. Case Description We present a unique case of DRUJ dysfunction following volar plate fixation of bilateral distal radius fractures and analyze the biomechanical causes of this complication. As a result of a relatively excessive tilt of the precontoured locking plate (in comparison to the patient's particular anatomy), the fracture on one side was "over-reduced," disrupting the biomechanics of the DRUJ, causing a supination block. Clinical Relevance Volar locking plates are not a panacea to all distal radius fractures. Plate selection and fixation technique must include consideration of patient anatomy. Robust plates offer the advantage of providing rigid fixation but can be difficult to contour when reconstructing normal anatomy. Restoration of patient-specific anatomy is crucial to the management of distal radius fractures.

  4. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures

    PubMed Central

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2014-01-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3–12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact. PMID:26269728

  5. [Three-dimensional Finite Element Analysis to T-shaped Fracture of Pelvis in Sitting Position].

    PubMed

    Fan, Yanping; Lei, Jianyin; Liu, Haibo; Li, Zhiqiang; Cai, Xianhua; Chen, Weiyi

    2015-10-01

    We developed a three-dimensional finite element model of the pelvis. According to Letournel methods, we established a pelvis model of T-shaped fracture with its three different fixation systems, i. e. double column reconstruction plates, anterior column plate combined with posterior column screws and anterior column plate combined with quadrilateral area screws. It was found that the pelvic model was effective and could be used to simulate the mechanical behavior of the pelvis. Three fixation systems had great therapeutic effect on the T-shaped fracture. All fixation systems could increase the stiffness of the model, decrease the stress concentration level and decrease the displacement difference along the fracture line. The quadrilateral area screws, which were drilled into cortical bone, could generate beneficial effect on the T-type fracture. Therefore, the third fixation system mentioned above (i. e. the anterior column plate combined with quadrilateral area screws) has the best biomechanical stability to the T-type fracture.

  6. Cost-effectiveness analysis of fixation options for intertrochanteric hip fractures.

    PubMed

    Swart, Eric; Makhni, Eric C; Macaulay, William; Rosenwasser, Melvin P; Bozic, Kevin J

    2014-10-01

    Intertrochanteric hip fractures are a major source of morbidity and financial burden, accounting for 7% of osteoporotic fractures and costing nearly $6 billion annually in the United States. Traditionally, "stable" fracture patterns have been treated with an extramedullary sliding hip screw whereas "unstable" patterns have been treated with the more expensive intramedullary nail. The purpose of this study was to identify parameters to guide cost-effective implant choices with use of decision-analysis techniques to model these common clinical scenarios. An expected-value decision-analysis model was constructed to estimate the total costs and health utility based on the choice of a sliding hip screw or an intramedullary nail for fixation of an intertrochanteric hip fracture. Values for critical parameters, such as fixation failure rate, were derived from the literature. Three scenarios were evaluated: (1) a clearly stable fracture (AO type 31-A1), (2) a clearly unstable fracture (A3), or (3) a fracture with questionable stability (A2). Sensitivity analysis was performed to test the validity of the model. The fixation failure rate and implant cost were the most important factors in determining implant choice. When the incremental cost for the intramedullary nail was set at the median value ($1200), intramedullary nailing had an incremental cost-effectiveness ratio of $50,000/quality-adjusted life year when the incremental failure rate of sliding hip screws was 1.9%. When the incremental failure rate of sliding hip screws was >5.0%, intramedullary nails dominated with lower cost and better health outcomes. The sliding hip screw was always more cost-effective for A1 fractures, and the intramedullary nail always dominated for A3 fractures. As for A2 fractures, the sliding hip screw was cost-effective in 70% of the cases, although this was highly sensitive to the failure rate. Sliding hip screw fixation is likely more cost-effective for stable intertrochanteric fractures (A1) or those with questionable stability (A2), whereas intramedullary nail fixation is more cost-effective for reverse obliquity fractures (A3). These conclusions are highly sensitive to the fixation failure rate, which was the major influence on the model results. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  7. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    PubMed Central

    2011-01-01

    Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires) and volar plate fixation using fixed-angle screws (locking-plates). The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956 PMID:21914196

  8. Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system.

    PubMed

    Voss, K; Kull, M; Hässig, M; Montavon, P

    2009-01-01

    To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture localisation and type, primary fracture repair or revision surgery, single or double plating, and complications for each patient were noted. Additionally, implant size, number of screws, number of cortices engaged with screws, and number of empty holes across the fracture were evaluated in fractures where a single plate had been applied. Eighteen humeral, 18 radial, 20 femoral, and 10 tibial fractures were treated. The Unilock system was used for primary repair in 44 fractures and for revision surgery in 22 fractures. Two plates were applied in 17 fractures, and a single plate was applied in 49 fractures. Follow-up radiographs were taken four to 109 weeks postoperatively. Complications were seen in 12 animals and 13 fractures (19.7%). Fixation failure occurred in seven fractures (10.6%). Cases with a single plate that suffered fixation failure had thinner screws in relation to bone diameter than cases with double plates, and more screws in a main fragment than those without fixation failure. The Unilock system is a suitable implant for fracture fixation of long bones in cats and small dogs.

  9. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    PubMed

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  10. The management of tibial pilon fractures with the Ilizarov fixator: The role of ankle arthroscopy.

    PubMed

    El-Mowafi, Hani; El-Hawary, Ahmed; Kandil, Yasser

    2015-12-01

    Pilon fractures usually result from high energy trauma, and are commonly associated with extensive soft tissue damage which prevents the use of open reduction and internal fixation. This study was designed to evaluate the use of the Ilizarov external fixator in the treatment of pilon fractures of the ankle, and to determine whether arthroscopy of the ankle could improve the outcome. From February 2011 to May 2013 a total of 23 patients with unilateral closed pilon fractures were divided into two groups treated with and without arthroscopy during fixation with the Ilizarov external fixator. The fractures were classified according to the AO Rüdi and Allgőwer classification. Follow up ranged from 10 to 37 months with a mean of 18 months. All cases were evaluated at follow up by the AOFAS and the Bone et al. grading system. According to Bone et al. there were 3 cases excellent, 4 cases good, 2 cases fair, and 2 cases poor in Group A (without arthroscopy), whereas there were 4 cases excellent, 6 cases good, 2 cases fair in Group B (with arthroscopy). The AOFAS score for Group A was 77.8±5.8, and for Group B was 78.4±6.9. We concluded that the Ilizarov external fixator is an excellent method in treating pilon fractures as it minimizes the need for extensive surgery. We also conclude that the use of arthroscopy during pilon fracture fixation did not add statistically significant improvement to our results and it needs longer term investigation to assess its advantage - if any - to the final outcome. level 2. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes.

    PubMed

    Anwar, Adeel; Lv, Decheng; Zhao, Zhi; Zhang, Zhen; Lu, Ming; Nazir, Muhammad Umar; Qasim, Wasim

    2017-04-01

    Appropriate fixation method for the posterior malleolar fractures (PMF) according to the fracture size is still not clear. Aim of this study was to evaluate the outcomes of the different fixation methods used for fixation of PMF by finite element analysis (FEA) and to compare the effect of fixation constructs on the size of the fracture computationally. Three dimensional model of the tibia was reconstructed from computed tomography (CT) images. PMF of 30%, 40% and 50% fragment sizes were simulated through computational processing. Two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior buttress plate were analysed for three different fracture volumes. The simulated loads of 350N and 700N were applied to the proximal tibial end. Models were fixed distally in all degrees of freedom. In single limb standing condition, the posterior plate group produced the lowest relative displacement (RD) among all the groups (0.01, 0.03 and 0.06mm). Further nodal analysis of the highest RD fracture group showed a higher mean displacement of 4.77mm and 4.23mm in AP and PA lag screws model (p=0.000). The amounts of stress subjected to these implants, 134.36MPa and 140.75MPa were also significantly lower (p=0.000). There was a negative correlation (p=0.021) between implant stress and the displacement which signifies a less stable fixation using AP and PA lag screws. Progressively increasing fracture size demands more stable fixation construct because RD increases significantly. Posterior buttress plate produces superior stability and lowest RD in PMF models irrespective of the fragment size. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.

    PubMed

    Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven

    2010-05-01

    This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.

  13. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    PubMed

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p < 0.05): open fracture (OR 3.78; 95% CI 2.71-5.27), compartment syndrome (OR 3.53; 95% CI 2.13-5.86), operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  14. [Case-control study on effects of external fixation combined with limited internal fixation for the treatment of Pilon fractures of Rüedi-Allgower type III].

    PubMed

    Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng

    2014-01-01

    To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P < 0.05): the external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (P< 0.05). Treatment of external fixation with limited internal fixation in the treatment of Pilon fracture of Rüedi-Allgower type III is effective and safe.

  15. Reconstruction of the lateral tibia plateau fracture with a third triangular support screw: A biomechanical study.

    PubMed

    Moran, Eduardo; Zderic, Ivan; Klos, Kajetan; Simons, Paul; Triana, Miguel; Richards, R Geoff; Gueorguiev, Boyko; Lenz, Mark

    2017-10-01

    Split fractures of the lateral tibia plateau in young patients with good bone quality are commonly treated using two minimally invasive percutaneous lag screws, followed by unloading of the knee joint. Improved stability could be achieved with the use of a third screw inserted either in the jail-technique fashion or with a triangular support screw configuration. The aim of this study was to investigate under cyclic loading the compliance and endurance of the triangular support fixation in comparison with the standard two lag-screw fixation and the jail technique. Lateral split fractures of type AO/OTA 41-B1 were created on 21 synthetic tibiae and subsequently fixed with one of the following three techniques for seven specimens: standard fixation by inserting two partially threaded 6.5 mm cannulated lag screws parallel to each other and orthogonal to the fracture plane; triangular support fixation-standard fixation with one additional support screw at the distal end of the fracture at 30° proximal inclination; and jail fixation-standard fixation with one additional orthogonal support screw inserted in the medial nonfractured part of the bone. Mechanical testing was performed under progressively increasing cyclic compression loading. Fragment displacement was registered via triggered radiographic imaging. Mean construct compliance was 3.847 × 10 -3  mm/N [standard deviation (SD) 0.784] for standard fixation, 3.838 × 10 -3  mm/N (SD 0.242) for triangular fixation, and 3.563 × 10 -3  mm/N (SD 0.383) for jail fixation, with no significant differences between the groups ( p  = 0.525). The mean numbers of cycles to 2 mm fragment dislocation, defined as a failure criterion, were 12,384 (SD 2267) for standard fixation, 17,708 (SD 2193) for triangular fixation, and 14,629 (SD 5194) for jail fixation. Triangular fixation revealed significantly longer endurance than the standard one ( p  = 0.047). Triangular support fixation enhanced interfragmentary stability at the ultimate stage of dynamic loading. However, the level of improvement seems to be limited and may not legitimate the intervention with an additional third screw.

  16. Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture.

    PubMed

    Zhang, Wei; Luo, Cong-Feng; Putnis, Sven; Sun, Hui; Zeng, Zhi-Min; Zeng, Bing-Fang

    2012-03-01

    The posterolateral shearing tibial plateau fracture is uncommon in the literature, however with the increased usage of computer tomography (CT), the incidence of these fractures is no longer as low as previously thought. Few studies have concentrated on this fracture, least of all using a biomechanical model. The purpose of this study was to compare and analyse the biomechanical characteristics of four different types of internal fixation to stabilise the posterolateral shearing tibial plateau fracture. Forty synthetic tibiae (Synbone, right) simulated the posterolateral shearing fracture models and these were randomly assigned into four groups; Group A was fixed with two anterolateral lag screws, Group B with an anteromedial Limited Contact Dynamic Compression Plate (LC-DCP), Group C with a lateral locking plate, and Group D with a posterolateral buttress plate. Vertical displacement of the posterolateral fragment was measured using three different strengths of axial loading force, and finally loaded until fixation failure. It was concluded that the posterolateral buttress plate is biomechanically the strongest fixation method for the posterolateral shearing tibial plateau fracture. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Early Fixation of Calcaneus Fractures.

    PubMed

    Swords, Michael P; Penny, Phillip

    2017-03-01

    The treatment of calcaneus fractures is controversial. Historically, most operatively treated fractures have been approached with a lateral extensile incision requiring delay in operative treatment until swelling has improved. There is a current trend and interest in small incision approaches allowing, and in some cases requiring, earlier operative fixation. Clinical scenarios amenable to consideration for early fixation are reviewed. The sinus tarsi surgical approach and reduction techniques are outlined in detail. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Advantages of external hybrid fixators for treating Schatzker V-VI tibial plateau fractures: A retrospective study of 40 cases.

    PubMed

    Gross, J-B; Gavanier, B; Belleville, R; Coudane, H; Mainard, D

    2017-10-01

    Proximal tibia fractures make up 1% of all fractures in adults. The fractures classified as Schatzker V and VI fractures can compromise knee structure and function. They are challenging to treat and often have complications. While plate fixation is the gold standard, the resulting infection rate has led us to favor external hybrid fixation. The aims of this study were to assess the radiographic and functional outcomes along with the complication rate when using this method and to compare them to historical plate fixation data. This was a retrospective study of 40 patients. The complications, quality of reduction, IKS, Lysholm and Rasmussen functional scores at the latest follow-up and factors affecting the functional outcome were evaluated. These parameters were compared to published results from plate fixation studies. The deep infection rate was 2.5%. The union rate was 80%. Satisfactory reduction was obtained in 70% of cases; however, 52% of patients had malunion. The mean IKS score was 73.74, the mean Rasmussen score was 22.85 and the mean Lysholm score was 75.53. Age, reduction at latest follow-up, mechanical axis and anteroposterior laxity had a significant effect on the functional outcome. Despite the malunion rate being higher than other studies, the functional outcomes were nearly identical based on the variables measured. There are several advantages associated with using a hybrid external fixator: shorter operative time, less bleeding, shorter hospital stays and lower infection rate. Hybrid external fixation is a reliable fracture fixation method that leads to satisfactory functional outcomes, while reducing the infection rate and allowing arthroplasty to be performed in the future if needed. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    PubMed

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve injury. Four patients had a longer recovery period due to stiffness, associated wrist fracture and elbow dislocation. The CaSO4 bone substitute was replaced by normal appearing trabecular bone texture at an average of 6 months in all patients. In our experience, we have found the use of locking plates, calcium sulphate bone substitute and tuberosity repair with high-strength sutures to be a safe and reliable method of internal fixation for complex proximal humeral fractures and fracture-dislocations. Furthermore, we have also found the use of the extended deltoid-splitting approach to be safe and to provide excellent exposure facilitating accurate reduction for fixation of the fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P <0.000 01) and total complications( I (2)=0%, RR =0.71, 95% CI 0.59-0.85, Z =3.65, P =0.000 3) ), DASH scores( I (2)=37%, MD =-5.67, 95% CI -8.31--3.04, Z =4.22, P <0.000 1) and volar tilt( I (2)=78%, MD =2.29, 95% CI 0.33-4.24, Z =2.30, P =0.02)( P <0.05) at the end of follow-up period were noted. There were no statistically significant differences observed between two approaches with respect to the clinical outcomes (grip strength, flexion, extension, pronation, supination, radial deviation and ulnar deviation) and radiographic outcome(radial length) at the end of follow-up period( P <0.05). Conclusion: Both open reduction and internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  1. Surgical management of post-traumatic atlantoaxial rotatory fixation due to C2 facet fracture: 5 clinical cases.

    PubMed

    Peyriere, H; Graillon, T; Pesenti, S; Tropiano, P; Blondel, B; Fuentes, S

    2017-02-01

    Report the results of surgical treatment of post-traumatic atlantoaxial rotatory fixation (AARF) due to C2 articular facet fracture in adults. The records of five patients treated since 2009 for AARF due to a C2 articular facet fracture were analyzed retrospectively. Three women and two men with an average age of 60 years (27-82) were included, one of whom initially had neurological deficits. In all cases, the surgical strategy consisted of posterior fixation: Harms-type in four cases and trans-articular with hooks in one case. Dislocations due to fracture of the C2 articular facet are rare in adults; various treatment strategies have been described. In our experience, posterior screw fixation leads to satisfactory clinical and radiological outcomes. Fusion is not necessary in these cases because the dislocation is related to an asymmetric fracture without ligament damage. Posterior fixation provides satisfactory reduction of these injuries and leads to satisfactory bone union. This surgical treatment can be performed early on after the trauma and is an interesting alternative to conservative treatment. Copyright © 2016. Published by Elsevier Masson SAS.

  2. Fixation of mandibular fractures with biodegradable plates and screws.

    PubMed

    Yerit, Kaan C; Enislidis, Georg; Schopper, Christian; Turhani, Dritan; Wanschitz, Felix; Wagner, Arne; Watzinger, Franz; Ewers, Rolf

    2002-09-01

    Little data exist regarding the use of biodegradable plates and screws for the internal fixation of human mandibular fractures. The purpose of this study was to evaluate the stability of biodegradable, self-reinforced poly-L-lactide plates and screws for the internal fixation of fractures of the human mandible. Twenty-two individuals (14 male, 8 female; average age, 26.3 years) with a variety of fracture patterns of the mandible underwent management with a biodegradable fixation system. After surgery, maxillomandibular fixation was applied in 3 cases. Images (panoramic radiograph, computed tomographic scan) were taken immediately after surgery and at the 4-week, 8-week, 12-week, and 24-week intervals. The follow-up period averaged 49.1 weeks (range, 22 to 78 weeks). Mucosal dehiscences over the resorbable devices were present in 2 patients. In 1 of these 2 cases, the material had to be replaced with titanium plates. Mucosal healing and consolidation of the fracture were normal in all other patients. Self-reinforced biodegradable osteosynthesis materials provide a reliable and sufficient alternative to conventional titanium plate systems.

  3. Fractures of the growing mandible.

    PubMed

    Kushner, George M; Tiwana, Paul S

    2009-03-01

    Oral and maxillofacial surgeons must constantly weigh the risks of surgical intervention for pediatric mandible fractures against the wonderful healing capacity of children. The majority of pediatric mandibular fractures can be managed with closed techniques using short periods of maxillomandibular fixation or training elastics alone. Generally, the use of plate- and screw-type internal fixation is reserved for difficult fractures. This article details general and special considerations for this surgery including: craniofacial growth & development, surgical anatomy, epidemiology evaluation, various fractures, the role rigid internal fixation and the Risdon cable in pediatric maxillofacial trauma. It concludes with suggestions concerning long-term follow-up care in light of the mobility, insurance obstacles, and family dynamics facing the patient population.

  4. Timing of definitive fixation of major long bone fractures: Can fat embolism syndrome be prevented?

    PubMed

    Blokhuis, Taco J; Pape, Hans-Christoph; Frölke, Jan-Paul

    2017-06-01

    Fat embolism is common in patients with major fractures, but leads to devastating consequences, named fat embolism syndrome (FES) in some. Despite advances in treatment strategies regarding the timing of definitive fixation of major fractures, FES still occurs in patients. In this overview, current literature is reviewed and optimal treatment strategies for patients with multiple traumatic injuries, including major fractures, are discussed. Considering the multifactorial etiology of FES, including mechanical and biochemical pathways, FES cannot be prevented in all patients. However, screening for symptoms of FES should be standard in the pre-operative work-up of these patients, prior to definitive fixation of major fractures. Copyright © 2017. Published by Elsevier Ltd.

  5. Malunited fracture of the body and condyle of the mandible : A Case Report.

    PubMed

    Yeluri, Ramakrishna; Baliga, Sudhindra; Munshi, Autar Krishen

    2010-07-01

    Mandibular fractures are the most common facial fractures seen in hospitalized children and their incidence increases with age. Treatment options include soft diet, intermaxillary fixation with eyelet wires, arch bars, circummandibular wiring, or stents. Alternative options include open reduction and internal fixation through either an intraoral or extraoral approach. Many factors complicate the management of pediatric mixed-dentition mandibular fractures: tooth eruption, short roots, developing tooth buds and growth issues. One major factor is the inherent instability of the occlusion in the mixed deciduous-permanent tooth phase. This case report documents a child in mixed dentition period with a complication arising due to direct fixation of the fractured mandible.

  6. Image-Guided Internal Fixation of an Oblique Sagittal Split Fracture of C1 Lateral Mass with Motion Preservation: A Technical Report.

    PubMed

    Malcolm, James G; Tan, Lee A; Johnson, Andrew K

    2017-07-20

    A sagittal split fracture of the C1 lateral mass is an unstable subtype of C1 fractures and has a high propensity for developing late deformities and pain with nonoperative management. A primary internal fixation of this type of fracture has been recently described with good clinical outcomes and preservation of motion. We present a modified technique of primary internal fixation using an obliquely inserted C1 lag screw with imaging guidance. We successfully treated a 55-year-old woman with a unilateral C1 oblique sagittal split fracture who failed nonoperative management. Technical nuances are discussed with a review of pertinent literature.

  7. Central tarsal bone fractures in horses not used for racing: Computed tomographic configuration and long-term outcome of lag screw fixation.

    PubMed

    Gunst, S; Del Chicca, F; Fürst, A E; Kuemmerle, J M

    2016-09-01

    There are no reports on the configuration of equine central tarsal bone fractures based on cross-sectional imaging and clinical and radiographic long-term outcome after internal fixation. To report clinical, radiographic and computed tomographic findings of equine central tarsal bone fractures and to evaluate the long-term outcome of internal fixation. Retrospective case series. All horses diagnosed with a central tarsal bone fracture at our institution in 2009-2013 were included. Computed tomography and internal fixation using lag screw technique was performed in all patients. Medical records and diagnostic images were reviewed retrospectively. A clinical and radiographic follow-up examination was performed at least 1 year post operatively. A central tarsal bone fracture was diagnosed in 6 horses. Five were Warmbloods used for showjumping and one was a Quarter Horse used for reining. All horses had sagittal slab fractures that began dorsally, ran in a plantar or plantaromedial direction and exited the plantar cortex at the plantar or plantaromedial indentation of the central tarsal bone. Marked sclerosis of the central tarsal bone was diagnosed in all patients. At long-term follow-up, 5/6 horses were sound and used as intended although mild osteophyte formation at the distal intertarsal joint was commonly observed. Central tarsal bone fractures in nonracehorses had a distinct configuration but radiographically subtle additional fracture lines can occur. A chronic stress related aetiology seems likely. Internal fixation of these fractures based on an accurate diagnosis of the individual fracture configuration resulted in a very good prognosis. © 2015 EVJ Ltd.

  8. A novel combined method of osteosynthesis in treatment of tibial fractures: a comparative study on sheep with application of rod-through-plate fixator and bone plating.

    PubMed

    Tralman, G; Andrianov, V; Arend, A; Männik, P; Kibur, R T; Nõupuu, K; Uksov, D; Aunapuu, M

    2013-04-01

    The study compares the efficiency of a new bone fixator combining periostal and intramedullary osteosynthesis to bone plating in treatment of tibial fractures in sheep. Experimental osteotomies were performed in the middle third of the left tibia. Animals were divided into two groups: in one group (four animals) combined osteosynthesis (rod-through-plate fixator, RTP fixator) was applied, and in the other group (three animals) bone plating was used. The experiments lasted for 10 weeks during which fracture union was followed by radiography, and the healing process was studied by blood serum markers reflecting bone turnover and by histological and immunohistochemical investigations. In the RTP fixator group, animals started to load body weight on the operated limbs the next day after the surgery, while in the bone plating group, this happened only on the seventh day. In the RTP fixator group, consolidation of fractures was also faster, as demonstrated by radiographical, histological, and immunohistochemical investigations and in part by blood serum markers for bone formation. It can be concluded that application of RTP fixation is more efficient than plate fixation in the treatment of experimental osteotomies of long bones in sheep. © 2012 Blackwell Verlag GmbH.

  9. Biomechanics of Two External Fixator Devices Used in Rat Femoral Fractures.

    PubMed

    Osagie-Clouard, Liza; Kaufmann, Joshua; Blunn, Gordon; Coathup, Melanie; Pendegrass, Catherine; Meeson, Richard; Briggs, Timothy; Moazen, Mehran

    2018-05-04

    The use of external fixators allows for the direct investigation of newly formed interfragmentary bone, and the radiographic evaluation of the fracture. We validated the results of a finite element model with the in vitro stiffness' of two widely used external fixator devices used for in vivo analysis of fracture healing in rat femoral fractures with differing construction (Ti alloy ExFix1 and PEEK ExFix2). Rat femoral fracture fixation was modelled using two external fixators. For both constructs an osteotomy of 2.75 mm was used, and offset maintained at 5 mm. Tufnol, served as standardized substitutes for rat femora. Constructs were loaded under axial compression and torsion. Overall axial and torsional stiffness were compared between the in vitro models and FE results. FE models were also used to compare the fracture movement and overall pattern of von Mises stress across the external fixators. In vitro axial stiffness of ExFix1 was 29.26 N/mm ± 3.83 compared to ExFix2 6.31 N/mm ± 0.67 (p* < 0.05). Torsional stiffness of ExFix1 was 47.5 Nmm/° ± 2.71 compared to ExFix2 at 19.1 Nmm/° ± 1.18 (p* < 0.05). FE results predicted similar comparative ratios between the ExFix1 and 2 as the in vitro studies. FE results predicted considerably larger interfragmentary motion in the ExFix2 comparing to ExFix1. We demonstrated significant differences in the stiffness' of the two external fixators as one would expect from such variable designs; yet, importantly we validated the utility of an FE model for the analysis and prediction of changes in fracture mechanics dependent on fixator choice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome.

    PubMed

    Pan, M; Chai, L; Xue, F; Ding, L; Tang, G; Lv, B

    2017-07-01

    The aim of this study was to compare the biomechanical stability and clinical outcome of external fixator combined with limited internal fixation (EFLIF) and open reduction and internal fixation (ORIF) in treating Sanders type 2 calcaneal fractures. Two types of fixation systems were selected for finite element analysis and a dual cohort study. Two fixation systems were simulated to fix the fracture in a finite element model. The relative displacement and stress distribution were analysed and compared. A total of 71 consecutive patients with closed Sanders type 2 calcaneal fractures were enrolled and divided into two groups according to the treatment to which they chose: the EFLIF group and the ORIF group. The radiological and clinical outcomes were evaluated and compared. The relative displacement of the EFLIF was less than that of the plate (0.1363 mm to 0.1808 mm). The highest von Mises stress value on the plate was 33% higher than that on the EFLIF. A normal restoration of the Böhler angle was achieved in both groups. No significant difference was found in the clinical outcome on the American Orthopedic Foot and Ankle Society Ankle Hindfoot Scale, or on the Visual Analogue Scale between the two groups (p > 0.05). Wound complications were more common in those who were treated with ORIF (p = 0.028). Both EFLIF and ORIF systems were tested to 160 N without failure, showing the new construct to be mechanically safe to use. Both EFLIF and ORIF could be effective in treating Sanders type 2 calcaneal fractures. The EFLIF may be superior to ORIF in achieving biomechanical stability and less blood loss, shorter surgical time and hospital stay, and fewer wound complications. Cite this article : M. Pan, L. Chai, F. Xue, L. Ding, G. Tang, B. Lv. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome. Bone Joint Res 2017;6:433-438. DOI: 10.1302/2046-3758.67.2000640. © 2017 Xue et al.

  11. Plate fixation versus intramedullary nailing of completely displaced midshaft fractures of the clavicle: a prospective randomised controlled trial.

    PubMed

    Fuglesang, H F S; Flugsrud, G B; Randsborg, P H; Oord, P; Benth, J Š; Utvåg, S E

    2017-08-01

    This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population. We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score. Plate fixation provided a faster functional recovery during the first six months compared with ESIN, but there was no difference after one year. The duration of surgery was shorter for ESIN (mean 53.4 minutes, 22 to 120) than for plate fixation (mean 69.7 minutes, 35 to 106, p < 0.001). The recovery after ESIN was slower with increasing fracture comminution and with open reduction (p < 0.05). Both methods return the patients to their pre-injury functional levels, but plate fixation has a faster recovery period in comminuted fractures than ESIN. ESIN has a shorter operative time and lower infection and implant rates of failure when using 2.5 mm nails or wider, suggesting that this is the preferred method in mid-shaft fractures with no comminution, whereas plate fixation is the superior method in comminuted fractures. Cite this article: Bone Joint J 2017;99-B:1095-1101. ©2017 The British Editorial Society of Bone & Joint Surgery.

  12. Minimally invasive surgical technique: Percutaneous external fixation combined with titanium elastic nails for selective treatment of tibial fractures.

    PubMed

    Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei

    2015-12-01

    Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. [Damage Control Surgery in Polytrauma Patients with Pelvic Fractures. Is It Possible to Use Internal Fixation?

    PubMed

    Havlůj, L; Džupa, V; Gürlich, R

    2017-01-01

    Current polytrauma management is multidisciplinary, with Damage Control Surgery (DCS), Damage Control Orthopaedics (DCO) and Damage Control Resuscitation (DCR) being applied in the first few hours after injury. The most severe group of polytrauma patients are those with circulatory instability and massive blood loss as a consequence of unstable pelvic fractures. In treating these patients, of crucial importance is the speed and quality of stabilisation of pelvic fracture fragments. The authors present two case reports of polytrauma patients with unstable pelvic fractures, in whom open reduction and internal fixation was performed on the anterior fracture segment through extended laparotomy in order to stop bleeding into the abdominopelvic cavity as part of the DCS approach. Key words: exsanguination, polytrauma, unstable pelvic fracture, plate fixation.

  14. A Retrospective Case Series of Carbon Fiber Plate Fixation of Ankle Fractures.

    PubMed

    Pinter, Zachariah W; Smith, Kenneth S; Hudson, Parke W; Jones, Caleb W; Hadden, Ryan; Elattar, Osama; Shah, Ashish

    2018-06-01

    Distal fibula fractures represent a common problem in orthopaedics. When fibula fractures require operative fixation, implants are typically made from stainless steel or titanium alloys. Carbon fiber implants have been used elsewhere in orthopaedics for years, and their advantages include a modulus of elasticity similar to that of bone, biocompatibility, increased fatigue strength, and radiolucency. This study hypothesized that carbon fiber plates would provide similar outcomes for ankle fracture fixation as titanium and steel implants. A retrospective chart review was performed of 30 patients who underwent fibular open reduction and internal fixation (ORIF). The main outcomes assessed were postoperative union rate and complication rate. The nonunion or failure rate for carbon fiber plates was 4% (1/24), and the union rate was 96% (23/24). The mean follow-up time was 20 months, and the complication rate was 8% (2/24). Carbon fiber plates are a viable alternative to metal plates in ankle fracture fixation, demonstrating union and complication rates comparable to those of traditional fixation techniques. Their theoretical advantages and similar cost make them an attractive implant choice for ORIF of the fibula. However, further studies are needed for extended follow-up and inclusion of larger patient cohorts. Level IV: Retrospective Case series.

  15. External fixation of "intertrochanteric" fractures.

    PubMed

    Gani, Naseem Ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-10-10

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.

  16. Unstable metacarpal and phalangeal fractures: treatment by internal fixation using AO mini-fragment plates and screws.

    PubMed

    Mumtaz, Mohammad Umar; Farooq, Muneer Ahmad; Rasool, Altaf Ahmad; Kawoosa, Altaf Ahmad; Badoo, Abdul Rashid; Dhar, Shabir Ahmad

    2010-07-01

    Accurate open reduction and internal fixation for metacarpal and phalangeal fractures of the hand is required in less than 5% of the patients; otherwise, closed treatment techniques offer satisfactory results in most of these cases as these fractures are stable either before or after closed reduction. AO mini-fragment screws and plates, when used in properly selected cases, can provide rigid fixation, allowing early mobilization of joints and hence good functional results while avoiding problems associated with protruding K-wires and immobilization. The advantages of such internal fixation urged us to undertake such a study in our state where such hand injuries are commonly seen. Forty patients with 42 unstable metacarpal and phalangeal fractures were treated with open reduction and internal fixation using AO mini-fragment screws and plates over a period of three years in a prospective manner. The overall results were good in 78.5% of cases, fair in 19% of cases and poor in 2.5% of cases, as judged according to the criteria of the American Society for Surgery of the Hand. This technique is a reasonable option for treating unstable metacarpal and phalangeal fractures as it provides a highly rigid fixation, which is sufficient to allow early mobilization of the adjacent joints, thus helping to achieve good functional results.

  17. Treatment of unstable distal radius fractures: non-invasive dynamic external fixator versus volar locking plate – functional and radiological outcome in a prospective case-controlled series

    PubMed Central

    Bajwa, Ali S.; Rammappa, Manju; Lee, Ling; Nanda, Rajesh

    2015-01-01

    Introduction: Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. Aims: To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate control group. Methods: Consecutive patients with closed DRF were included in a prospective case-controlled study. Patients were assigned to non-invasive external fixator or ORIF. Minimum follow-up was two years. Follow-up was at weeks 2, 4, 6, 8, 12, 26 and at one and two-year post-operatively. The outcome measures included demographic details, injury mechanism, AO fracture type, risk factors, body mass index (BMI), ulnar styloid fracture and dorsal comminution, radiographs, grip strength and DASH score. Results: Consecutive 50 patients were treated either with non-invasive external fixator (25/50) or with ORIF (25/50) and the mean age of the two groups was 53 years (SD 17.1) and 49 years (SD 19.5), respectively. Demographics were matched in two groups. In the non-invasive external fixator group, there were 10 AO Type-A, 5 Type-B and 10 Type-C fractures. The ORIF group included 8 Type-A, 6 Type-B and 11 Type-C fractures. The mean DASH score at three-months and one-year post-injury in non-invasive fixator group was 12.2 (SD 3.1) and 3.5 (SD 0.7), respectively, significantly greater than those of ORIF group 14.5 (SD 5.6) and 11.2 (SD 4.4), respectively (p < 0.05). Conclusion: DRF treated with non-invasive external fixator can give functional results superior to ORIF at three-months and the trend is maintained at one and two-year post-operatively. PMID:27163089

  18. [Clinical application of percutaneous iliosacral screws combined with pubic ramus screws in Tile B pelvic fracture].

    PubMed

    Xu, Qi-Fei; Lin, Kui-Ran; Zhao, Dai-Jie; Zhang, Song-Qin; Feng, Sheng-Kai; Li, Chen

    2017-03-25

    To investigate the application and effect of minimally invasive percutaneous anterior pelvic pubic ramus screw fixation in Tile B fractures. A retrospective review was conducted on 56 patients with posterior pelvic ring injury combined with fractures of anterior pubic and ischiadic ramus treated between May 2010 and August 2015, including 31 males and 25 females with an average age of 36.8 years old ranging from 35 to 65 years old. Based on the Tile classification, there were 13 cases of Tile B1 type, 28 cases of Tile B2 type and 15 cases of Tile B3 type. Among them, 26 patients were treated with sacroiliac screws combined with external fixation (external fixator group) and the other 30 patients underwent sacroiliac screw fixation combined with anterior screw fixation (pubic ramus screw group). Postoperative complications, postoperative ambulation time, fracture healing, blood loss, Majeed pelvic function score and visual analogue scale(VAS) were compared between two groups. Fifty-four patients were followed up from 3 to 24 months with a mean of 12 months. There were no significant difference in the peri-operative bleeding and operation time between two groups( P >0.05). The postoperative activity time and fracture healing time of pubic ramus screw group were shorter than those of the external fixator group, the differences were statistically significant( P <0.05). The Majeed score, VAS score of pubic ramus screw group were higher than those of the external fixator group, the differences were statistically significant( P <0.05). The incidence of postoperative complications of pubic ramus screw was lower than that of the external fixator group, the difference was statistically significant ( P <0.05). Percutaneous iliosacral screws fixation combined with the pubic ramus screw is an effective and safty treatment method to the Tile B pelvic fracture. It has advantages of early ambulation, relief of the pain and few complications.

  19. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].

    PubMed

    Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei

    2013-11-01

    To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P < 0.05). The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

  20. Comparison of stability of different types of external fixation.

    PubMed

    Grubor, Predrag; Grubor, Milan; Asotic, Mithat

    2011-01-01

    Stabilization of fractures by external fixator is based on the mechanical connecting of the pins, screwed into the proximal and distal bone fragment. Site of fracture is left without any foreign materials, which is essential for prevention of infections. Aim of this work is to compare stability of constructs bone model-external fixators of different types (Ortofix, Mitković, Charneley and Ilizarov). Stability is estimated under compression and bending (vertical and horizontal forces of 100 kg magnitudes, with distances between pins of4 cm). The mathematical-computer software (Tower, Planet and Planet Pro) was used in the laboratory for accurate measurements of MDP "Jelsingrad" company, Banjaluka. Interfragmental motions in millimeters at the appliance of vertical and horizontal forces were 2.80/2.56 at Ortofix (uniplanar fixator), 1.57/1.56 and fixator by Mitković-M20 (uniplanar fixator with convergent oriented pins), 0.16/0.28 at Charnely's external fixator (biplanar fixator), and 4.49/0.114 mm at Ilizarov's external fixator (fixator with two proximal and two distal rings, each attached on the 6 Kirschner wires). It has confirmed that uniplanar fixation is easier and provides sufficient biomechanics circumstances in the site of fracture for bone healing, especially if the pins are oriented convergently. Ilizarov's fixator is multiplanar fixator, but its stability is dependent of tightness of wires, and provides adequate stability only in transversal plane. By other words, each fixator has its indications; selection of the fixator should be based on theirs mechanic characteristics, fracture geometry, and potential of bone healing, with permanent simplification of treatment, which has to be safe and acceptable for the patient. The main advantage of this study is Sits nature-the comparison of four most used external fixators, by the only one possible way-on the bone model. Each other way of comparison would result with much more questions than answers, due to unacceptable high bias of other parameters, which significantly influences on the results of the study.

  1. Are Biodegradable Plates Applicable in Endoscope-Assisted Open Reduction and Internal Fixation of Mandibular Subcondyle Fractures?

    PubMed

    Son, Jang-Ho; Ha, Jinhee; Cho, Yeong-Cheol; Sung, Iel-Yong

    2017-08-01

    To investigate whether biodegradable plates are applicable in endoscope-assisted open reduction and internal fixation (EAORIF) of mandibular subcondyle fractures. This retrospective case-series study included patients with mandibular subcondyle fractures treated with EAORIF using an unsintered hydroxyapatite particles/poly-l-lactide biodegradable plate system, with at least 6 months of clinical follow-up data available. The outcome variables were fracture healing with postoperative stability and postoperative complications. Other variables included age, gender, fracture site, cause of injury, accompanying mandibular fracture, total follow-up period, fracture classification, extent of displacement, preoperative status of occlusion, preoperative mandibular movements, fixation materials in accompanying mandibular fracture, location and number of fixation plates, periods of intermaxillary fixation/elastic bands, and postoperative mandibular movements. Fracture healing in these patients was assessed by comparing the immediate postoperative cone-beam computed tomography (CBCT) images with those obtained at least 3 months after surgery. A total of 11 patients, 9 male and 2 female, with a mean ± standard deviation age of 35.3 ± 15.9 years, were included. The mean follow-up period was 18.8 ± 7.8 months. Four patients had an accompanying mandibular fracture. Two 4-hole, 2.0-mm biodegradable plates were fixed with 6-mm screws along the posterior border of the mandibular ramus and near the sigmoid notch. Complete bone formation around the fracture lines or fading of the fracture lines, with no change in the position of the fractured segments, was observed on the postoperative CBCT images at 3 months. With the exception of 2 patients, no patient complained of plate palpability, deviation in occlusion, or discomfort during the postoperative follow-up period. EAORIF using biodegradable plates for mandible subcondylar fractures is a stable and reliable method, with considerable advantages compared with titanium plates. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. The use of circular external fixators in the management of lower limb trauma in Dublin: a single surgeon's 20-year experience.

    PubMed

    O'Neill, B J; Fox, C M; Molloy, A P; O'hEireamhoin, S; Moore, D P

    2016-02-01

    It has been estimated that approximately 520,000 injury presentations are made to Irish accident and emergency departments each year. Fractures account for 20 % of these injuries. Circular external fixators (frames) have been shown to be a safe and effective method of treatment for long bone fractures where internal fixation is impossible or in-advisable. We present the outcomes of all frames applied at our institution for stabilisation of acute fractures over a 20-year period. We retrospectively reviewed a prospectively compiled database of all frames applied in our institution and identified all frames which were applied for acute lower limb trauma. We identified 68 fractures in 63 patients. There were 11 femoral fractures and 57 tibial fractures. All fractures were classified using the AO Classification system, and most fractures were Type C fractures. We used an Ilizarov frame for 53 fractures and a Taylor Spatial Frame for 15 fractures. The mean time in frame was 365 days for a femoral fracture and 230 days for a tibial fracture. There were five tibial non-unions giving an overall union rate of 93 %. Factors associated with non-union included high-energy trauma and cigarette smoking. The vast majority of lower limb fractures can be treated using 'conventional' methods. Complex fractures which are not amenable to open reduction and internal fixation or cast immobilisation can be treated in a frame with excellent results. The paucity of published reports regarding the use of frames for complex trauma reflects the under-utilisation of the technique.

  3. An alternative method in mandibular fracture treatment: bone graft use instead of a plate.

    PubMed

    Alagöz, Murat Sahin; Uysal, Ahmet Cagri; Sensoz, Omer

    2008-03-01

    In the treatment of the mandibular fractures, one of the main principles is to use the least amount of foreign material. We present an alternative technique that the bone grafts harvested from the fracture borders or from the iliac crest were used instead of plates and the fixation was done with screws. In the study including 24 mandible fractures, the bone grafts harvested from the fracture borders were used in the 10 favorable fractures and the bone grafts harvested from the iliac crest were used in the 14 unfavorable fractures. In the combined mandible fractures, four fractures were fixated with titanium plates and the other side with the bone graft. The patients, who were followed up for 12 to 20 months, were evaluated with macroscopic occlusion, panoramic graphs, and three-dimensional computerized tomographs. The advantage of this technique of fixation with the autogenous tissue is reduced infection rates and reduced operation costs. In the pediatric patients, the second session operation of plate removal is not necessary.

  4. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Three-dimensional finite element analysis and comparison of a new intramedullary fixation with interlocking intramedullary nail.

    PubMed

    Liu, Chang-cheng; Xing, Wen-zhao; Zhang, Ya-xing; Pan, Zheng-hua; Feng, Wen-ling

    2015-03-01

    This study was set to introduce a new intramedullary fixation, explore its biomechanical properties, and provide guidance for further biomechanical experiments. With the help of CT scans and finite element modeling software, finite element model was established for a new intramedullary fixation and intramedullary nailing of femoral shaft fractures in a volunteer adult. By finite element analysis software ANSYS 10.0, we conducted 235-2,100 N axial load, 200-1,000 N bending loads and 2-15 Nm torsional loading, respectively, and analyzed maximum stress distribution, size, and displacement of the fracture fragments of the femur and intramedullary nail. During the loading process, the maximum stress of our new intramedullary fixation were within the normal range, and the displacement of the fracture fragments was less than 1 mm. Our new intramedullary fixation exhibited mechanical reliability and unique advantages of anti-rotation, which provides effective supports during fracture recovery.

  6. Biomechanical analysis of tension band fixation for olecranon fracture treatment.

    PubMed

    Kozin, S H; Berglund, L J; Cooney, W P; Morrey, B F; An, K N

    1996-01-01

    This study assessed the strength of various tension band fixation methods with wire and cable applied to simulated olecranon fractures to compare stability and potential failure or complications between the two. Transverse olecranon fractures were simulated by osteotomy. The fracture was anatomically reduced, and various tension band fixation techniques were applied with monofilament wire or multifilament cable. With a material testing machine load displacement curves were obtained and statistical relevance determined by analysis of variance. Two loading modes were tested: loading on the posterior surface of olecranon to simulate triceps pull and loading on the anterior olecranon tip to recreate a potential compressive loading on the fragment during the resistive flexion. All fixation methods were more resistant to posterior loading than to an anterior load. Individual comparative analysis for various loading conditions concluded that tension band fixation is more resilient to tensile forces exerted by the triceps than compressive forces on the anterior olecranon tip. Neither wire passage anterior to the K-wires nor the multifilament cable provided statistically significant increased stability.

  7. Fixation of zygomatic and mandibular fractures with biodegradable plates

    PubMed Central

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    Context: In this prospective study, 13 randomly selected patients underwent treatment for zygomatic–complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. Aims: To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. Materials and Methods: In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Statistical Analysis Used: Descriptives, Frequencies, and Chi-square test were used. Results: In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Conclusions: Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome. PMID:23662255

  8. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis.

    PubMed

    Metcalfe, David; Hickson, Craig J; McKee, Lesley; Griffin, Xavier L

    2015-12-01

    It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures.

  9. Anesthetic and Surgical Management of a Bilateral Mandible Fracture in a Patient With Charcot-Marie-Tooth Disease: A Case Report.

    PubMed

    Smith, Jeffrey D; Minkin, Patton; Lindsey, Sean; Bovino, Brian

    2015-10-01

    This report describes the case of a 74-year-old man who had been diagnosed with Charcot-Marie-Tooth disease as a child. Because the patient had serious motor and sensory neuropathy associated with his disease, special anesthetic and surgical recommendations had to be considered before he underwent general anesthesia to repair his mandibular fracture. Repair of the mandible was performed under general anesthesia with a nasal endotracheal tube and the use of the nondepolarizing muscle relaxant rocuronium. Open reduction and internal fixation through extraoral approaches were used to fixate the displaced right subcondylar and symphyseal fractures. A closed reduction approach using maxillary fixation screws and a mandibular arch bar with light elastic guidance was used to treat a nondisplaced fracture of the left mandibular ramus. Rigid fixation allowed for avoidance of a period of intermaxillary fixation. General anesthesia and muscle relaxant were administered without complication. Treatment of bilateral mandibular fractures with combined open and closed approaches resulted in restoration of premorbid occlusion and masticatory function. Repair of mandibular fractures under general anesthesia appears to be a safe procedure in patients with Charcot-Marie-Tooth disease when appropriate anesthetic and surgical methods are used. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Management of tibial fractures using a circular external fixator in two calves.

    PubMed

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  11. Low Profile Mesh Plating for Patella Fractures: Video of a Novel Surgical Technique.

    PubMed

    Verbeek, Diederik O; Hickerson, Lindsay E; Warner, Stephen J; Helfet, David L; Lorich, Dean G

    2016-08-01

    Patella fractures can be challenging to treat particularly in the presence of inferior pole comminution. In this video we present a novel surgical technique for the treatment of patella fractures using a small fragment low profile mesh plate. Key points are the surgical exposure with direct visualization of the articular reduction, the preparation of the mesh plate to accommodate patellar anatomy and the augmentation of the construct using Krackow sutures to address inferior pole comminution. Low profile mesh plating allows for multiplanar fixation of patella fractures while avoiding implant and fixation problems related to tension band fixation. Our early experience with this technique is encouraging and it appears that this technique is useful for the treatment of the majority of patella fractures.

  12. Image-Guided Internal Fixation of an Oblique Sagittal Split Fracture of C1 Lateral Mass with Motion Preservation: A Technical Report

    PubMed Central

    Malcolm, James G; Johnson, Andrew K

    2017-01-01

    A sagittal split fracture of the C1 lateral mass is an unstable subtype of C1 fractures and has a high propensity for developing late deformities and pain with nonoperative management. A primary internal fixation of this type of fracture has been recently described with good clinical outcomes and preservation of motion. We present a modified technique of primary internal fixation using an obliquely inserted C1 lag screw with imaging guidance. We successfully treated a 55-year-old woman with a unilateral C1 oblique sagittal split fracture who failed nonoperative management. Technical nuances are discussed with a review of pertinent literature. PMID:28948116

  13. Late extensor pollicis longus rupture following plate fixation in Galeazzi fracture dislocation

    PubMed Central

    Sabat, Dhananjaya; Dabas, Vineet; Dhal, Anil

    2014-01-01

    Late rupture of extensor pollicis longus (EPL) tendon after Galeazzi fracture dislocation fixation is an unknown entity though it is a well-established complication following distal radius fractures. We report the case of a 55-year old male who presented with late EPL tendon rupture 4 months following internal fixation of Galeazzi fracture dislocation with a Locking Compression Plate (LCP). He was managed with extensor indicis proprius (EIP) transfer to restore thumb extension. At 4 years followup, functional result of the transfer was good. We identify possible pitfalls with this particular patient and discuss how to avoid them in future. PMID:25143650

  14. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    PubMed

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  15. Can we improve fixation and outcomes? Use of bone substitutes.

    PubMed

    Moroni, Antonio; Larsson, Sune; Hoang Kim, Amy; Gelsomini, Letizia; Giannoudis, Peter V

    2009-07-01

    Hip fractures secondary to osteoporosis are common in the elderly. Stabilizing these fractures until union is achieved is a challenge due to poor bone stock and insufficient purchase of the implant to the bone. The reported high rate of complications has prompted extensive research in the development of fixation techniques. Furthermore, manipulation of both the local fracture environment in terms of application of growth factors, scaffolds, and mesenchymal cells and the systemic administration of agents promoting bone formation and bone strength has been considered as a treatment option with promising results. There are only a few evidence-based studies reporting on fixation augmentation techniques. This article reports on the efficacy of bone graft substitutes for the fixation of hip fractures, in particular calcium phosphates, which have been used as granules, cements, and implant coatings.

  16. Biomechanical consequences of callus development in Hoffmann, Wagner, Orthofix and Ilizarov external fixators.

    PubMed

    Juan, J A; Prat, J; Vera, P; Hoyos, J V; Sánchez-Lacuesta, J; Peris, J L; Dejoz, R; Alepuz, R

    1992-09-01

    A theoretical analysis by a finite elements model (FEM) of some external fixators (Hoffmann, Wagner, Orthofix and Ilizarov) was carried out. This study considered a logarithmic progress of callus elastic characteristics. A standard configuration of each fixator was defined where design and application characteristics were modified. A comparison among standard configurations and influence of every variation was made with regard to displacement and load transmission at the fracture site. An experimental evaluation of standard configurations was performed with a testing machine. After experimental validation of the theoretical model was achieved, an application of physiological loads which act on a fractured limb during normal gait was analysed. A minimal contribution from an external fixator to the total rigidity of the bone-callus-fixator system was assessed when a callus showing minimum elastic characteristics had just been established. Insufficient rigidity from the fixation devices to assure an adequate immobilization during the early stages of fracture healing was verified. However, regardless of the external fixator, callus development was the overriding element for the rigidity of the fixator-bone system.

  17. Clinical and radiographic outcomes of femoral head fractures: excision vs. fixation of fragment in Pipkin type I: what is the optimal choice for femoral head fracture?

    PubMed

    Park, Kyung-Soon; Lee, Keun-Bae; Na, Bo-Ram; Yoon, Taek-Rim

    2015-07-01

    In this work, we present relatively long-term results of femoral head fractures with a specific focus on Pipkin type I fractures. Fifty-nine femoral head fractures were treated according to modified Pipkin's classification as follows: type I, small fragment distal to the fovea centralis (FC); type II, large fragment distal to the FC; type III, large fragment proximal to the FC; type IV, comminuted fracture. There were 15 cases of type I, 28 of type II, 9 of type III, and 7 of type IV fractures. Conservative treatment with skeletal traction was performed in 4 type II cases, excision of the fragment in 15 type I and 10 type II cases, fixation of the fragment in 14 type II and all 9 type III cases, and total hip replacement in all 7 type IV cases. The overall clinical and radiographic outcomes were evaluated using previously published criteria, focusing on the results in Pipkin type I fractures with relatively large fragments. Based on Epstein criteria, in type II fractures, excellent or good clinical results were seen in 6 of 10 patients (60.0 %) treated by excision of the fragment and 12 of 14 patients (85.7 %) treated by internal fixation (p = 0.05). Also, excellent or good radiologic results were seen in 4 of 10 (40.0 %) patients treated by excision of the fragment and 12 of 14 (85.7 %) patients treated by internal fixation (p = 0.03). Even in Pipkin type I fractures, if the fragment is large (modified Pipkin type II), early reduction and internal fixation can produce good results.

  18. Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures.

    PubMed

    2014-06-26

    Hip fractures are a common type of fragility fracture that afflict 293,000 Americans (over 5,000 per week) and 35,000 Canadians (over 670 per week) annually. Despite the large population impact the optimal fixation technique for low energy femoral neck fractures remains controversial. The primary objective of the FAITH study is to assess the impact of cancellous screw fixation versus sliding hip screws on rates of revision surgery at 24 months in individuals with femoral neck fractures. The secondary objective is to determine the impact on health-related quality of life, functional outcomes, health state utilities, fracture healing, mortality and fracture-related adverse events. FAITH is a multi-centre, multi-national randomized controlled trial utilizing minimization to determine patient allocation. Surgeons in North America, Europe, Australia, and Asia will recruit a total of at least 1,000 patients with low-energy femoral neck fractures. Using central randomization, patients will be allocated to receive surgical treatment with cancellous screws or a sliding hip screw. Patient outcomes will be assessed at one week (baseline), 10 weeks, 6, 12, 18, and 24 months post initial fixation. We will independently adjudicate revision surgery and complications within 24 months of the initial fixation. Outcome analysis will be performed using a Cox proportional hazards model and likelihood ratio test. This study represents major international efforts to definitively resolve the treatment of low-energy femoral neck fractures. This trial will not only change current Orthopaedic practice, but will also set a benchmark for the conduct of future Orthopaedic trials. The FAITH trial is registered at ClinicalTrials.gov (Identifier NCT00761813).

  19. Complications in operative fixation of calcaneal fractures

    PubMed Central

    Li, Ying; Bao, Rong-Hua; Jiang, Zhi-Qiang; Wu, Huo-Yan

    2016-01-01

    Objective: The purpose of this study focused on a number of factors that have been implicated in calcaneal complications and find the incidence of wound complications. Methods: This was a retrospective study. A total of 162 patients (176 feet) who underwent calcaneal fractures between 2007 and 2012 were included. The patient’s personal details, age, time from injury to surgery, cause of injury, type of fracture, operative details, operating and tourniquet times were collected from hospital computers and paper records. Evidence of complications including wound infection, wound necrosis, pain, malunion, nonunion, impingement, loss of fixation, ect were studied. Results: Forty-seven of one hundred and seventy-six fractures (26.704%) had complications, wound infection was noted in seven fractures (3.977%), twelve fractures developed necrosis (6.818%), 14 fractures (7.955%) developed pain. Malunion was found in five fractures (2.841%), nonunion in two fractures (1.136%) and loss of fixation in four fractures (2.272%). Three neurologic injury was also seen in our study (1.705%). Operating time, time from injury to surgery and type of fracture had some association with complications in operative fixation of calcaneal fractures, which showed a statistically significant improvement (P=0.000, 0.031, 0.020, respectively), but there were no evidence that age and tourniquet time affect the incidence of complication after calcaneal fracture surgery (P=0.119, 0.682, respectively). Conclusions: Despite developments in the surgical treatment of calcaneal fracture, wound complications still remain inevitable. Advanced imaging techniques, less invasive surgical procedures, wealth of anatomical knowledge, surgical experience and better postoperative care should be ensured. PMID:27648028

  20. "A" shape plate for open rigid internal fixation of mandible condyle neck fracture.

    PubMed

    Kozakiewicz, Marcin; Swiniarski, Jacek

    2014-09-01

    Reduction of the fracture is crucial for proper outcome of the treatment. The stability of reduction is closed connected to the method of its fixation. The topic of condylar fracture osteosynthesis still remains highly controversial and challenging. That is why authors decided to propose novel design of the fixating plate and the example of its application. The aim of this study was to present A-shape plate dedicated to rigid fixation of mandible condyle neck fracture. A-shape condylar plate (ACP) design is prepared of 1.0 mm thick titanium alloy (grade 5) sheet: posterior and anterior bars are reinforced by widening to 2.5 mm and anatomically curved along the compression and traction lines in ramus and condylar neck. Superior three-hole-group has triangular organization and located on the level of condylar head. The inferior extensions of the bars are equipped in three holes located at each of lower tails. Connecting bar (2.0 mm wide) connects the first hole of each lower tails closing upper part of ACP in triangular shape. The connecting bar runs along compression line of condylar neck. Holes in ACP has 2.0 mm diameter for locking or normal screws. Height of ACP is 31 mm. The proposed new type of plate was compared by finite element analysis (FEA) to nowadays manufactured 9-hole trapezoid plate as the most similar device. ACP design was evaluated by finite element analysis (FEA) and later applied in patient affected with high condylar neck fracture complicated by fracture of coronoid process. FEA revealed high strength of ACP and more stabile fixation than trapezoid plate. The result was caused by multipoint fixation at three regions of the plate and reinforced bars supported by semi-horizontal connecting bar. Clinical application of ACP was as versatile as makes possible to simultaneous fixation of high condylar neck and coronoid process fracture. Application of proposed A-shape condylar plate would be possible in all levels of neck fractures and can be use for stabilization additionally existed coronoid process fracture. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Treatment of open tibial shaft fracture with soft tissue and bone defect caused by aircraft bomb--case report.

    PubMed

    Golubović, Zoran; Vidić, Goran; Trenkić, Srbobran; Vukasinović, Zoran; Lesić, Aleksandar; Stojiljković, Predrag; Stevanović, Goran; Golubović, Ivan; Visnjić, Aleksandar; Najman, Stevo

    2010-01-01

    Aircraft bombs can cause severe orthopaedic injuries. Tibia shaft fractures caused by aircraft bombs are mostly comminuted and followed by bone defects, which makes the healing process extremely difficult and prone to numerous complications. The goal of this paper is to present the method of treatment and the end results of treatment of a serious open tibial fracture with soft and bone tissue defects resulting from aircraft bomb shrapnel wounds. A 26-year-old patient presented with a tibial fracture as the result of a cluster bomb shrapnel wound. He was treated applying the method of external bone fixation done two days after wounding, as well as of early coverage of the lower leg soft tissue defects done on the tenth day after the external fixation of the fracture. The external fixator was removed after five months, whereas the treatment was continued by means of functional plaster cast for another two months. The final functional result was good. Radical wound debridement, external bone fixation of the fracture, and early reconstruction of any soft tissue and bone defects are the main elements of the treatment of serious fractures.

  2. Internal fixators: a safe option for managing distal femur fractures?

    PubMed Central

    Batista, Bruno Bellaguarda; Salim, Rodrigo; Paccola, Cleber Antonio Jansen; Kfuri, Mauricio

    2014-01-01

    OBJECTIVE: Evaluate safety and reliability of internal fixator for the treatment of intra-articular and periarticular distal femur fractures. METHODS: Retrospective data evaluation of 28 patients with 29 fractures fixed with internal fixator was performed. There was a predominance of male patients (53.5%), with 52% of open wound fractures, 76% of AO33C type fractures, and a mean follow up of 21.3 months. Time of fracture healing, mechanical axis deviation, rate of infection and postoperative complications were registered. RESULTS: Healing rate was 93% in this sample, with an average time of 5.5 months. Twenty-seven percent of patients ended up with mechanical axis deviation, mostly resulting from poor primary intra-operative reduction. There were two cases of implant loosening; two implant breakage, and three patients presented stiff knee. No case of infection was observed. Healing rate in this study was comparable with current literature; there was a high degree of angular deviation, especially in the coronal plane. CONCLUSION: Internal fixators are a breakthrough in the treatment of knee fractures, but its use does not preclude application of principles of anatomical articular reduction and mechanical axis restoration. Level of Evidence II, Retrospective Study. PMID:25061424

  3. Biodegradable fixation of mandibular fractures in children: stability and early results.

    PubMed

    Yerit, Kaan C; Hainich, Sibylle; Enislidis, Georg; Turhani, Dritan; Klug, Clemens; Wittwer, Gert; Ockher, Michael; Undt, Gerhard; Kermer, Christian; Watzinger, Franz; Ewers, Rolf

    2005-07-01

    The aim of this study was to assess the safety and efficiency of biodegradable self-reinforced (SR-PLDLA) bone plates and screws in open reduction and internal fixation of mandible fractures in children. Thirteen patients (5 female, 8 male; mean age 12 years, range 5-16 years) were operated on various fractures of the mandible (2 symphyseal, 6 parasymphyseal, 4 body, 3 angle, 1 ramus, 2 condylar fractures). The mean follow-up time was 26.4 months (range 10.9-43.4 months). Intermaxillary fixation was applied in cases with concomitant condylar fractures up to 3 weeks. Primary healing of the fractured mandible was observed in all patients. Postoperative complications were minor and transient. The outcome of the operations was not endangered. Adverse tissue reactions to the implants, malocclusion, and growth restrictions did not occur during the observation period. Pediatric patients benefit from the advantages of resorbable materials, especially from faster mobilization and the avoidance of secondary removal operations. Based on these preliminary results, self-reinforced fixation devices are safe and efficient in the treatment of pediatric mandible fractures. However, further clinical investigations are necessary to evaluate the long-term reliability.

  4. Displaced clavicle fractures in adolescents: facts, controversies, and current trends.

    PubMed

    Pandya, Nirav K; Namdari, Surena; Hosalkar, Harish S

    2012-08-01

    There is an increasing trend toward stabilization and fixation of markedly displaced midshaft clavicle fractures in adolescents. Recent studies in the adult literature have shown a greater prevalence of symptomatic malunion, nonunion, and poor functional outcomes after nonsurgical management of displaced fractures. Fixation of displaced midshaft clavicle fractures can restore length and alignment, resulting in shorter time to union. Symptomatic malunion after significantly displaced fractures in adolescents may be more common than previously thought. Adolescents often have high functional demands, and their remodeling potential is limited. Knowledge of bone biology and the effects of shortening, angulation, and rotation on shoulder girdle mechanics is critical in decision making in order to increase the likelihood of optimal results at skeletal maturity. Selection of fixation is dependent on many factors, including fracture type, patient age, skeletal maturity, and surgeon comfort.

  5. Dorsal or Volar Plate Fixation of the Distal Radius: Does the Complication Rate Help Us to Choose?

    PubMed

    Disseldorp, D J G; Hannemann, P F W; Poeze, M; Brink, P R G

    2016-08-01

    Internal fixation with plates is a reliable fixation technique for the treatment of distal radius fractures. An ongoing discussion exists whether volar or dorsal plating is the appropriate technique. In clinical practice, volar plate fixation is usually preferred because of the assumed lower complication frequency. However, recent studies with the newer generation low-profile dorsal plates reported lower complication rates. The aim of our study was to evaluate the differences in complication rates between volar and dorsal plate for the treatment of distal radius fractures in adult patients. A total of 214 patients with acute distal radius fractures were included in this retrospective study with a minimum 2 years of follow-up. In total, 123 patients were treated with dorsal plate fixation and 91 patients with volar plate fixation. Our primary study outcome was complication rate. The overall risk for complications was 15.4% in the dorsal group and 14.3% in the volar group (p = 0.81). A total of 19 patients had implant removal due to complications: 11 patients in the dorsal group and 8 patients in the volar group (p = 0.97). There is no preferred plate fixation technique based on these study results. In our opinion, decision for type of plate fixation should be based on fracture type and surgeon's experience with the specific approach and plate types. Therapeutic level III.

  6. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    PubMed

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  7. Intra-articular fractures of the distal tibia

    PubMed Central

    Sitnik, Alexandre; Beletsky, Aleksander; Schelkun, Steven

    2017-01-01

    Results of the treatment of intra-articular fractures of the distal tibia have improved significantly during the last two decades. Recognition of the role of soft tissues has led to the development of a staged treatment strategy. At the first stage, joint-bridging external fixation and fibular fixation are performed. This leads to partial reduction of the distal tibial fracture and allows time for the healing of soft tissues and detailed surgical planning. Definitive open reduction and internal fixation of the tibial fracture is performed at a second stage, when the condition of the soft tissues is safe. The preferred surgical approach(es) is chosen based on the fracture morphology as determined from standard radiographic views and computed tomography. Meticulous atraumatic soft-tissue handling and the use of modern fixation techniques for the metaphyseal component such as minimally invasive plate osteosynthesis further facilitate healing. Cite this article: EFORT Open Rev 2017;2:352-361. DOI: 10.1302/2058-5241.2.150047 PMID:28932487

  8. Use of the S3 Corridor for Iliosacral Fixation in a Dysmorphic Sacrum: A Case Report.

    PubMed

    El Dafrawy, Mostafa H; Strike, Sophia A; Osgood, Greg M

    2017-01-01

    The S1 and S2 corridors are the typical osseous pathways for iliosacral screw fixation of posterior pelvic ring fractures. In dysmorphic sacra, the S1 screw trajectory is often different from that in normal sacra. We present a case of iliosacral screw placement in the third sacral segment for fixation of a complex lateral compression type-3 pelvic fracture in a patient with a dysmorphic sacrum. In patients with dysmorphic sacra and unstable posterior pelvic ring fractures or dislocations, the S3 corridor may be a feasible osseous fixation pathway that can be used in a manner equivalent to the S2 corridor in a normal sacrum.

  9. Strength analysis of clavicle fracture fixation devices and fixation techniques using finite element analysis with musculoskeletal force input.

    PubMed

    Marie, Cronskär

    2015-08-01

    In the cases, when clavicle fractures are treated with a fixation plate, opinions are divided about the best position of the plate, type of plate and type of screw units. Results from biomechanical studies of clavicle fixation devices are contradictory, probably partly because of simplified and varying load cases used in different studies. The anatomy of the shoulder region is complex, which makes it difficult and expensive to perform realistic experimental tests; hence, reliable simulation is an important complement to experimental tests. In this study, a method for finite element simulations of stresses in the clavicle plate and bone is used, in which muscle and ligament force data are imported from a multibody musculoskeletal model. The stress distribution in two different commercial plates, superior and anterior plating position and fixation including using a lag screw in the fracture gap or not, was compared. Looking at the clavicle fixation from a mechanical point of view, the results indicate that it is a major benefit to use a lag screw to fixate the fracture. The anterior plating position resulted in lower stresses in the plate, and the anatomically shaped plate is more stress resistant and stable than a regular reconstruction plate.

  10. [Utility of nickel-titanium shape memory alloys of vertebral body reduction fixator with assisted distraction bar].

    PubMed

    Man, Yi; Zheng, Yue-huan; Cao, Peng; Chen, Bo; Zheng, Tao; Sun, Chang-hui; Lu, Jiong

    2011-06-07

    To test the nickel-titanium (Ni-Ti) shape memory alloys of vertebral body reduction fixator with assisted distraction bar for the treatment of traumatic and osteoporotic vertebral body fracture. A Ni-Ti shape memory alloys of vertebral body reduction fixator with assisted distraction bar was implanted into the compressed fracture specimens through vertebral pedicle with the radiographic monitoring to reduce the collapsed endplate as well as distract the compressed vertebral fracture. Radiographic film and computed tomographic reconstruction technique were employed to evaluate the effects of reduction and distraction. A biomechanic test machine was used to measure the fatigue and the stability of deformation of fixation segments. Relying on the effect of temperature shape memory, such an assembly could basically reduce the collapsed endplate as well as distract the compressed vertebral fracture. And when unsatisfied results of reduction and distraction occurred, its super flexibility could provide additional distraction strength. A Ni-Ti shape memory alloys of vertebral body reduction fixator with assisted distraction bar may provide effective endplate reduction, restore the vertebral height and the immediate biomechanic spinal stability. So the above assembly is indicated for the treatment of traumatic and osteoporotic vertebral body fracture.

  11. Biomechanical comparison of cemented versus non-cemented anterior screw fixation in type II odontoid fractures in the elderly: a cadaveric study.

    PubMed

    Rehousek, Petr; Jenner, Edward; Holton, James; Czyz, Marcin; Capek, Lukas; Henys, Petr; Kulvajtova, Marketa; Krbec, Martin; Skala-Rosenbaum, Jiri

    2018-05-18

    Odontoid process fractures are the most common injuries of the cervical spine in the elderly. Anterior screw stabilization of type II odontoid process fractures improves survival and function in these patients but may be complicated by failure of fixation. The present study aimed to determine whether cement augmentation of a standard anterior screw provides biomechanically superior fixation of type II odontoid fractures in comparison with a non-cemented standard screw. Twenty human cadaveric C2 vertebrae from elderly donors (mean age 83 years) were obtained. Anderson and D'Alonzo type IIa odontoid fracture was created by transverse osteotomy, and fluoroscopy-guided anterior screw fixation was performed. The specimens were divided into two matched groups. The cemented group (n=10) had radiopaque high viscosity polymethylmethacrylate cement injected via Jamshidi needle into the base of the odontoid process. The other group was not augmented. A V-shaped punch was used for loading the odontoid in an anteroposterior direction until failure. The failure state was defined as screw cutout or 5% force decrease. Mean failure load and bending stiffness were calculated. The mean failure load for the cemented group was 352±12 N compared with 168±23 N for the non-cemented group (p<.001). The mean initial stiffness of the non-cemented group was 153±19 N/mm compared with 195±29 N/mm for the cemented group (p<.001) CONCLUSIONS: Cement augmentation of an anterior standard screw fixation of type II odontoid process fractures in elderly patients significantly increased load to failure under anteroposterior load in comparison with non-augmented fixation. This may be a valuable technique to reduce failure of fixation. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    PubMed Central

    Kulshrestha, Vikas

    2008-01-01

    Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection. PMID:19753227

  13. A theoretical analysis and finite element simulation of fixator-bone system stiffness on healing progression.

    PubMed

    Li, Jianfeng; Zhao, Xia; Hu, Xiaojie; Tao, Chunjing; Ji, Run

    2018-03-01

    The unilateral external fixator has become a quick and easy application for fracture stabilization of the extremities; the main value for evaluation of mechanical stability of the external fixator is stiffness. The stiffness property of the external fixator affects the local biomechanical environment of fractured bone. In this study, a theoretical model with changing Young's modulus of the callus is established by using the Castigliano's theory, investigating compression stiffness, torsional stiffness and bending stiffness of the fixator-bone system during the healing process. The effects of pin deviation angle on three stiffness methods are also investigated. In addition, finite element simulation is discussed regarding the stress distribution between the fixator and bone. The results reveal the three stiffness evaluation methods are similar for the fixator-bone system. Finite element simulation shows that with increased healing time, the transmission of the load between the fixator and bone are different. In addition, the finite element analyses verify the conclusions obtained from the theoretical model. This work helps orthopedic doctors to monitor the progression of fracture healing and determine the appropriate time for removal of a fixation device and provide important theoretical methodology.

  14. Surgical repair of femoral fractures in New World camelids: five cases (1996-2003).

    PubMed

    Shoemaker, R W; Wilson, D G

    2007-04-01

    Five New World camelids were admitted to the Western College of Veterinary Medicine between 1996 and 2003 for evaluation of femoral fractures. There were three alpacas and two llamas. Four of the animals were female and three were less than 3 months of age. Fracture configurations consisted of distal physeal fractures (three), a comminuted diaphyseal/metaphyseal fracture, and a transverse diaphyseal fracture. Fractures were diagnosed with a combination of physical examination and radiographs in all cases. All five fractures were repaired with internal fixation and three animals were discharged from the hospital with fractures that healed. One cria underwent successful internal fixation but died from pulmonary oedema during recovery from anaesthesia. Postoperative complications were rare and limited to inadequate fracture stability in one alpaca and prolonged recovery to weight bearing in another. One llama with a comminuted metaphyseal fracture, repaired with a 4.5 mm dynamic compression plate, subsequently had catastrophic failure of the bone 17 days after surgery. Overall the clients were pleased with the outcome of discharged animals. Although femoral fractures are considered rare, they pose a unique opportunity for the large animal veterinarian to successfully achieve fracture union with the aid of internal fixation.

  15. [Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study].

    PubMed

    Buchvald, P; Čapek, L; Barsa, P

    2015-01-01

    PURPOSE OF THE STUDY The aim of the experiment was to compare the bending stiffness of an intact odontoid process with bending stiffness after its simulated type II fracture was fixed with a single lag screw. The experiment was done with a desire to answer the question of whether a single osteosynthetic screw is sufficient for good fixation of a type II odontoid fracture. MATERIAL AND METHODS The C2 vertebrae of six cadavers were used. With simultaneous measurement of odontoid bending stiffness, the occurrence of a fracture (type IIA, Grauer's modification of the Anderson- D'Alonzo classification) was simulated using action exerted by a tearing machine in the direction perpendicular to the odontoid axis. Each odontoid fracture was subsequently treated by direct osteosynthesis with a single lag screw inserted in the axial direction by a standard surgical procedure in order to provide conditions similar to those achieved by routine surgical management. The treated odontoid process was subsequently subjected to the same tearing machine loading as applied to it at the start of the experiment. The bending stiffness measured was then compared with that found before the fracture occurred. The results were statistically evaluated by the t-test for paired samples at the level of significance α = 0.05. RESULTS The average value of bending stiffness for odontoid processes of intact vertebrae at the moment of fracture occurrence was 318.3 N/mm. After single axial lag screw fixation of the fracture, the average bending stiffness for the odontoid processes treated was 331.3 N/mm. DISCUSSION Higher values of bending stiffness after screw fixation were found in all specimens and, in comparison with the values recorded before simulated fractures, the increase was statistically significant. CONCLUSIONS The results of our measurements suggest that the single lag screw fixation of a type IIA odontoid fracture will provide better stability for the fracture fragment-C2 body complex on antero-posterior perpendicular loading than can be found in intact C2 vertebrae. Key words: odontoid fracture, odontoid fixation, bending stiffness, lag screw.

  16. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    PubMed

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  17. A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis.

    PubMed

    Liu, Yun-Feng; Fan, Ying-Ying; Jiang, Xian-Feng; Baur, Dale A

    2017-11-15

    The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. The customized fixation system with topological optimized structure has good biomechanical behavior for mandibular angle fracture because the stress, strain and displacement within the plate could be reduced significantly comparing to conventional "one mini-plate" or "two mini-plates" systems. The design methodology for customized fixation system could be used for other fractures in mandible or other bones to acquire better mechanical behavior of the system and improve stable environment for bone healing. And together with SLM, the customized plate with optimal structure could be designed and fabricated rapidly to satisfy the urgent time requirements for treatment.

  18. Long-term results of various therapy concepts in severe pilon fractures.

    PubMed

    Koulouvaris, Panagiotis; Stafylas, Kosmas; Mitsionis, Gregory; Vekris, Marios; Mavrodontidis, Alexandros; Xenakis, Theodore

    2007-07-01

    Intra-articular fractures of the tibia plafond are among the most challenging of orthopaedic problems. This is a retrospective case-control study of surgically treated pilon fractures which was undertaken to compare the internal fixation with the two external fixation methods. This is a case-control study of 55 patients with 55 pilon fractures. There were 36 type C and 19 type B. Of these fractures, 24 were open and 31 closed. Three surgical protocols were used. In 20 patients, Group A, a half pin external fixator with ankle spanning was performed. The mean age of patients was 42.0 years (22.0-74.0), SD 14.1 and the mean follow-up was 77.7 months (38.0-132.0), SD 25.4. In 22 patients, Group B, a single ankle sparring ring hybrid external fixator under a small arthrotomy was performed. The mean age of patients was 48.4 years (28.0-76.0), SD 12.4 and mean follow-up was 67.9 months (36.0-132.0), SD 27.8. In 13 patients, Group C, a two-staged internal fixation was performed. The mean age was 45.6 years (30.0-66.0), SD 9.7 and the mean follow-up was 78.6 months (55.0-132.0), SD 25.4. We addressed the dissimilarity of the type of fracture in each group performing supplementary stratified analyses within each fracture type group. Group A had union in 6.9 months, group B in 5.6 months and group C in 5.1 months; P = 0.009. Six patients (Group A), two (Group B), and one (Group C) had limitation of ankle motion; P = 0.47. One patient from group C developed infection and the plate was removed. Four patients (Group A), one (Group B), and one (Group C) have developed posttraumatic arthritis (loss of joint space and pain); P = 0.25. Seven patients from Group A have reduced their activities; P = 0.004. In stratified statistical analysis by type of fracture, the associations noted for both fracture groups combined were also noted separately within each fracture group. In this long term follow-up study, the two-staged internal fixation and the hybrid fixation with small arthrotomy were equally efficacious in achieving bone union. Patients in external fixation with the ankle spanning had a significantly higher rate of delayed union. Also more patients in this group have reduced their activities.

  19. Two-stage open reduction and internal fixation versus limited internal fixation combined with external fixation: a meta-analysis of postoperative complications in patients with severe Pilon fractures.

    PubMed

    Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He

    2018-01-01

    Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.

  20. Outcome of limb fracture repair in rabbits: 139 cases (2007-2015).

    PubMed

    Sasai, Hiroshi; Fujita, Daisuke; Seto, Eiko; Denda, Yuki; Imai, Yutaro; Okamoto, Kanako; Okamura, Kensaku; Furuya, Masaru; Tani, Hiroyuki; Sasai, Kazumi

    2018-02-15

    OBJECTIVE To evaluate outcome of limb fracture repair in rabbits. DESIGN Retrospective case series. ANIMALS 139 client-owned rabbits with limb fractures treated between 2007 and 2015. PROCEDURES Medical records were reviewed for information on fracture location, fracture treatment, and time to fracture healing. RESULTS 25 rabbits had fractures involving the distal aspects of the limbs (ie, metacarpal or metatarsal bones, phalanges, and calcaneus or talus). Fractures were treated in 23 of these 25 rabbits (external coaptation, n = 17; external skeletal fixation, 4; and intramedullary pinning, 2) and healed in all 23, with a median healing time of 28 days (range, 20 to 45 days). One hundred ten rabbits had long bone fractures, and fractures were treated in 100 of the 110 (external skeletal fixation, n = 89; bone plating, 1; intramedullary pinning, 3; and external coaptation, 7). The percentage of fractures that healed was significantly lower for open (14/18) than for closed (26/26) tibial fractures and was significantly lower for femoral (19/26) and treated humeral (4/6) fractures than for radial (23/24) or closed tibial (26/26) fractures. Micro-CT was used to assess fracture realignment during external skeletal fixator application and to evaluate fracture healing. CONCLUSIONS AND CLINICAL RELEVANCE The prognosis for rabbits with limb fractures was good, with fractures healing in most rabbits following fracture repair (109/123). Micro-CT was useful in assessing fracture realignment and evaluating fracture healing.

  1. Evaluation of Fibular Fracture Type vs Location of Tibial Fixation of Pilon Fractures.

    PubMed

    Busel, Gennadiy A; Watson, J Tracy; Israel, Heidi

    2017-06-01

    Comminuted fibular fractures can occur with pilon fractures as a result of valgus stress. Transverse fibular fractures can occur with varus deformation. No definitive guide for determining the proper location of tibial fixation exists. The purpose of this study was to identify optimal plate location for fixation of pilon fractures based on the orientation of the fibular fracture. One hundred two patients with 103 pilon fractures were identified who were definitively treated at our institution from 2004 to 2013. Pilon fractures were classified using the AO/OTA classification and included 43-A through 43-C fractures. Inclusion criteria were age of at least 18 years, associated fibular fracture, and definitive tibial plating. Patients were grouped based on the fibular component fracture type (comminuted vs transverse), and the location of plate fixation (medial vs lateral) was noted. Radiographic outcomes were assessed for mechanical failures. Forty fractures were a result of varus force as evidenced by transverse fracture of the fibula and 63 were due to valgus force with a comminuted fibula. For the transverse fibula group, 14.3% mechanical complications were noted for medially placed plate vs 80% for lateral plating ( P = .006). For the comminuted fibular group, 36.4% of medially placed plates demonstrated mechanical complications vs 16.7% for laterally based plates ( P = .156). Time to weight bearing as tolerated was also noted to be significant between groups plated medially and laterally for the comminuted group ( P = .013). Correctly assessing the fibular component for pilon fractures provides valuable information regarding deforming forces. To limit mechanical complications, tibial plates should be applied in such a way as to resist the original deforming forces. Level of Evidence Level III, comparative study.

  2. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box.

    PubMed

    Harness, Neil G

    2016-03-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41-82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70-64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0-2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates.

  3. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box

    PubMed Central

    Harness, Neil G.

    2016-01-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41–82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70–64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0–2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates. PMID:26855830

  4. External fixation of “intertrochanteric” fractures

    PubMed Central

    Gani, Naseem ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-01-01

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with “intertrochanteric” fractures remain unsuita ble for open reduction and internal fixation. The aim of this study was to analyze the results of external fixation of “intertrochanteric” fractures in high-risk geriatric patients in a developing country. The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58–90 years) with “intertrochanteric” fractures, in whom external fixation was performed, are reported. Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients. This study demonstrated that external fixation of “intertrochantric” fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country. PMID:21808680

  5. Comparison of two-transsacral-screw fixation versus triangular osteosynthesis for transforaminal sacral fractures.

    PubMed

    Min, Kyong S; Zamorano, David P; Wahba, George M; Garcia, Ivan; Bhatia, Nitin; Lee, Thay Q

    2014-09-01

    Transforaminal pelvic fractures are high-energy injuries that are translationally and rotationally unstable. This study compared the biomechanical stability of triangular osteosynthesis vs 2-transsacral-screw fixation in the repair of a transforaminal pelvic fracture model. A transforaminal fracture model was created in 10 cadaveric lumbopelvic specimens. Five of the specimens were stabilized with triangular osteosynthesis, which consisted of unilateral L5-to-ilium lumbopelvic fixation and ipsilateral iliosacral screw fixation. The remaining 5 were stabilized with a 2-transsacral-screw fixation technique that consisted of 2 transsacral screws inserted across S1. All specimens were loaded cyclically and then loaded to failure. Translation and rotation were measured using the MicroScribe 3D digitizing system (Revware Inc, Raleigh, North Carolina). The 2-transsacral-screw group showed significantly greater stiffness than the triangular osteosynthesis group (2-transsacral-screw group, 248.7 N/mm [standard deviation, 73.9]; triangular osteosynthesis group, 125.0 N/mm [standard deviation, 66.9]; P=.02); however, ultimate load and rotational stiffness were not statistically significant. Compared with triangular osteosynthesis fixation, the use of 2 transsacral screws provides a comparable biomechanical stability profile in both translation and rotation. This newly revised 2-transsacral-screw construct offers the traumatologist an alternative method of repair for vertical shear fractures that provides biplanar stability. It also offers the advantage of percutaneous placement in either the prone or supine position. Copyright 2014, SLACK Incorporated.

  6. Taylor spatial frame fixation in patients with multiple traumatic injuries: study of 57 long-bone fractures.

    PubMed

    Sala, Francesco; Elbatrawy, Yasser; Thabet, Ahmed M; Zayed, Mahmoud; Capitani, Dario

    2013-08-01

    To evaluate the Taylor spatial frame (TSF) for primary and definitive fixation of lower limb long-bone fractures in patients with multiple traumatic injuries. Retrospective. Level I trauma center. Consecutive series of 52 patients, 57 fractures (25 femoral and 32 tibial), treated between 2005 and 2009. Forty-nine fractures (86%) were open. Injury Severity Score ≥16 for all patients. Fifty-four fractures (95%) underwent definitive fixation with the TSF and 3 were treated primarily within 48 hours of injury. In 22 cases (39%), fractures were acutely reduced with the TSF, fixed to bone and the struts in sliding mode without further adjustment, and in 35 cases (61%), the total residual deformity correction program was undertaken. Clinical and radiological. Complete union was obtained in 52 fractures (91%) without additional surgery at an average of 29 weeks. Four nonunions and 1 delayed union occurred. Results based on Association for the Study and Application of the Method of Ilizarov criteria: 74% excellent, 16% good, 4% fair, and 7% poor for bone outcomes and 35% excellent, 47% good, and 18% fair for functional outcomes. Eighty-eight percent of patients returned to preinjury work activities. Primary and definitive fixation with the TSF is effective. Advantages include continuity of device until union, reduced risk of infection, early mobilization, restoration of primary defect caused by bone loss, easy and accurate application, convertibility and versatility compared with a monolateral fixator, and improved union rate and range of motion for lower extremity long-bone fractures in patients with multiple traumatic injuries.

  7. Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures

    PubMed Central

    Kopylov, Philippe; Geijer, Mats; Tägil, Magnus

    2009-01-01

    Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. Methods 50 patients with an unstable or comminute distal radius fracture were randomized to either closed reduction and bridging external fixation, or open reduction and internal fixation using the TriMed system. The primary outcome parameter was grip strength, but the patients were followed for 1 year with objective clinical assessment, subjective outcome using DASH, and radiographic examination. Results At 1 year postoperatively, grip strength was 90% (SD 16) of the uninjured side in the internal fixation group and 78% (17) in the external fixation group. Pronation/supination was 150° (15) in the internal fixation group and 136° (20) in the external fixation group at 1 year. There were no differences in DASH scores or in radiographic parameters. 5 patients in the external fixation group were reoperated due to malunion, as compared to 1 in the internal fixation group. 7 other cases were classified as radiographic malunion: 5 in the external fixation group and 2 in the internal fixation group. Interpretation Internal fixation gave better grip strength and a better range of motion at 1 year, and tended to have less malunions than external fixation. No difference could be found regarding subjective outcome. PMID:19857180

  8. Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures

    PubMed Central

    Meffert, Rainer H.; Raschke, Michael J.; Blunk, Torsten; Ochman, Sabine

    2014-01-01

    Purpose. To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. Methods. Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical screw fixation followed. Under cyclic loading, the displacement, and in subsequent load-to-failure tests, the maximum load and stiffness were measured. Results. For the monocortical screw fixation of the locking plate, a similar displacement, maximum load, and stiffness could be demonstrated compared to the bicortical screw fixation of the nonlocking plate. Conclusions. Locking plates in monocortical configuration may function as a useful alternative to the currently common treatment with bicortical fixations. Thereby, irritation of the flexor tendons would be avoided without compromising the stability, thus enabling the necessary early functional rehabilitation. PMID:24757429

  9. Check radiography after fixation of hip fractures: is it necessary?

    PubMed

    Mohanty, K; Gupta, S K; Evans, R M

    2000-12-01

    Technological advances in radiography in the form of image intensification has not only made internal fixation of femoral neck fracture much easier but these high resolution films can be saved as hard copies and can also be reversed into 'positives' at a later date. However, requesting routine post-operative check radiographs for these fractures are still a common practice. A retrospective study was carried out to compare the quality of image intensifier films with conventional post-operative radiographs. 79 sets of films were reviewed with particular reference to adequacy of fixation and possible joint penetration by the screws. No significant difference was noted between the two sets of films. We suggest that routine post-operative radiographs after femoral neck fracture fixation are unnecessary unless there is some clinical indication. This has significant implications in relation to patient discomfort, radiation exposure and cost-effectiveness.

  10. Screw fixation versus arthroplasty versus plate fixation for 3-part radial head fractures.

    PubMed

    Wu, P H; Shen, L; Chee, Y H

    2016-04-01

    To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with a 2-mm Synthes plate (n=12) for 3-part Mason types III or IV radial head and neck fracture were reviewed. Treatment option was decided by the surgeon based on the presence of associated injury, neurovascular deficit, and the Mason classification. Bone union, callus formation, and complications (such as heterotopic ossification, malunion, and nonunion) were assessed by an independent registrar or consultant using radiographs. The Mayo Elbow Performance Score and range of motion were assessed by an independent physiotherapist. The median age of the 3 groups were comparable. Associated injuries were most common in patients with arthroplasty, followed by screw fixation and plate fixation (61.5% vs. 50% vs. 33%, p=0.54). The median time to bone union was shorter after screw fixation than plate fixation (55 vs. 86 days, p=0.05). No patient with screw fixation had nonunion, but 4 patients with plate fixation had nonunion. The 3 groups were comparable in terms of the mean Mayo Elbow Performance Score (p=0.56) and the mean range of motion (p=0.45). The complication rate was highest after plate fixation, followed by screw fixation and arthroplasty (50% vs. 18.8% vs. 15.4%, p=0.048). Excluding 20 patients with associated injuries (8 in screw fixation, 8 in arthroplasty, and 4 in plate fixation), the 3 groups were comparable in terms of the median time to bone union (p=0.109), mean Mayo Elbow Performance Score (p=0.260), mean range of motion (p=0.162), and complication rate (p=0.096). Headless compression screw fixation is a viable option for 3-part radial head fracture. It achieves earlier bone union with fewer complications.

  11. Recent advances in fixation of the craniomaxillofacial skeleton.

    PubMed

    Meslemani, Danny; Kellman, Robert M

    2012-08-01

    Fixation of the craniomaxillofacial skeleton is an evolving aspect for facial plastic, oral and maxillofacial, and plastic surgery. This review looks at the recent advances that aid in reduction and fixation of the craniomaxillofacial skeleton. More surgeons are using resorbable plates for craniomaxillofacial fixation. A single miniplate on the inferior border of the mandible may be sufficient to reduce and fixate an angle fracture. Percutaneous K-wires may assist in plating angle fractures. Intraoperative computed tomography (CT) may prove to be useful for assessing reduction and fixation. Resorbable plates are becoming increasingly popular in orthognathic surgery and facial trauma surgery. There are newer operative techniques for fixating the angle of the mandible. Also, the utilization of the intraoperative CT provides immediate feedback for accurate reduction and fixation. Prebent surgical plates save operative time, decrease errors, and provide more accurate fixation.

  12. Minimal Invasive Surgical Treatment of Fragility Fractures of the Pelvis.

    PubMed

    Rommens, Pol Maria; Wagner, Daniel; Hofmann, Alex

    2017-01-01

    The incidence of fragility fractures of the pelvis is increasing quickly. The characteristics of these fractures are different from pelvic ring disruptions in adults. Fragility fractures of the pelvis are the consequence of a low-energy trauma which occurs in a patient with an important decrease of bone mineral density. Due to a consistent pattern of alteration of bone mass distribution in the sacrum, other fracture morphologies occur than in younger adults. The leading symptom is immobilizing pain in the lower back, in the buttocks, in the inguinal region and/or at the pubic symphysis. Conventional radiographs and CT will show the presence and localization of the fractures in the anterior and posterior pelvic ring. A new, comprehensive classification system distinguishes four categories of instability. This first criterion is most important, because it also gives hints for the preferred type of treatment. The second criterion, leading to the subtypes in the four categories, is the localization of the instability in the posterior pelvic ring. This criterion points the way towards the type of the surgical procedure to be used. When a surgical treatment is chosen, the procedure should be as minimal invasive as possible. Different techniques for percutaneous or less invasive fixation of the posterior pelvic ring have been developed. Their advantages and limitations are presented: sacroplasty, iliosacral screw osteosynthesis, cement augmentation, transiliac internal fixation, trans-sacral osteosynthesis, lumbopelvic fixation. Fractures of the anterior pelvic ring also need special attention. Retrograde transpubic screw fixation is recommended for pubic rami fractures. Fractures of the pubic body and instabilities of the pubic symphysis need bridging plate osteosynthesis. We do not recommend anterior pelvic external fixation in elderly because of the risk of pin track infection and pin loosening. Celsius.

  13. Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury.

    PubMed

    Mohammed, R; Syed, S; Metikala, S; Ali, Sa

    2011-09-01

    With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures.

  14. Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury

    PubMed Central

    Mohammed, R; Syed, S; Metikala, S; Ali, SA

    2011-01-01

    Background: With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. Materials and Methods: 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. Results: At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. Conclusion: We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures. PMID:21886929

  15. Treatment of displaced intra-articular calcaneal fractures with triangular tube-to-bar external fixation: long-term clinical follow-up and radiographic analysis.

    PubMed

    Roukis, Thomas S; Wünschel, Markus; Lutz, Hans-Peter; Kirschner, Peter; Zgonis, Thomas

    2008-04-01

    Sixty-six feet (62 patients) with displaced intra-articular calcaneal fractures underwent manual reduction and distraction with the use of a triangular tube-to-bar external fixation device and were retrospectively reviewed at a minimum of 1-year post-operative. Final radiographic follow-up revealed complete consolidation in all fractures, maintenance of reduction, and limited degenerative osteoarthrosis about the subtalar joint. Our results indicate that with proper application and attention to detail, restoration of calcaneal morphology using triangular tube-to-bar external fixation should be considered a viable alternative in the treatment of displaced intra-articular fractures of the calcaneus.

  16. [Surgical approach of internal fixation of maxillofacial fracture].

    PubMed

    Liu, Dashun; Zhang, Ruizhen; Dong, Xiao

    2013-11-01

    By summary and analysis of rigid internal fixation for the treatment of maxillofacial fractures incision and exposure, investigate the plate reasonable surgical approach of fracture reduction and fixation titanium. Summary of the 76 surgical cases, Counting the statistics of the number that the surgery ways choose by facial incision and fractures location, analysis of the indications for surgery and the advantages and disadvantages of various surgical approaches. Followed up for more than six months, in order to observe the recovery of occlusal function and the facial cosmetic results. The upper jaw or cheek bone has the more possibility in facial fracture, which used of a small incision hidden under the lip gingival sulcus and lower eyelid. After six months, the facial wound healing recover in good occlusal with no obvious scarring. Reasonable choice of surgical incision can make the fracture site exposure and the facial aesthetic effect into account.

  17. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    PubMed

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  18. No Higher Risk of CRPS After External Fixation of Distal Radial Fractures - Subgroup Analysis Under Randomised Vitamin C Prophylaxis.

    PubMed

    Zollinger, Paul E; Kreis, Robert W; van der Meulen, Hub G; van der Elst, Maarten; Breederveld, Roelf S; Tuinebreijer, Wim E

    2010-02-17

    Operative and conservative treatment of wrist fractures might lead to complex regional pain syndrome (CRPS) type I.In our multicenter dose response study in which patients with distal radial fractures were randomly allocated to placebo or vitamin C in a daily dose of 200mg, 500mg or 1500mg during 50 days, an operated subgroup was analyzed.48 (of 427) fractures) were operated (11.2%). Twenty-nine patients (60%) were treated with external fixation, 14 patients (29%) with K-wiring according to Kapandji and five patients (10%) with internal plate fixation. The 379 remaining patients were treated with a plaster.In the operated group of patients who received vitamin C no CRPS (0/37) was seen in comparison with one case of CRPS (Kapandji technique) in the operated group who received placebo (1/11 = 9%, p=.23). There was no CRPS after external fixation.In the conservatively treated group 17 cases of CRPS (17/379 = 4.5%) occurred in comparison with one in case of CRPS in the operated group (1/48 = 2.1%, p=.71).External fixation doesn't necessarily lead to a higher incidence of CRPS in distal radial fractures. Vitamin C may also play a role in this. This subgroup analysis in operated distal radial fractures showed no CRPS occurrence with vitamin C prophylaxis.

  19. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P <0.05). There were no statistically significant differences observed between two approaches with respect to nounion, re-operation, complex regional pain syndrome, carpal tunnel syndrome, neurapraxia, tendonitis, painful hardware, scar( P >0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  20. Hybrid external fixation in high-energy elbow fractures: a modular system with a promising future.

    PubMed

    Lerner, A; Stahl, S; Stein, H

    2000-12-01

    Severe, high-energy, periarticular elbow injuries producing a "floating joint" are a major surgical challenge. Their reconstruction and rehabilitation are not well documented. Therefore, the following reports our experience with treating such injuries caused by war wounds. Seven adults with compound open peri- and intra-articular elbow fractures were treated in hybrid ring tubular fixation frames. After debridement, bone stabilization, and neurovascular reconstructions, early controlled daily movements were started in the affected joint. These seven patients had together seven humeral, five radial, and six ulnar fractures. All fractures united at a median time of 180 days. No deep infection developed. The functional end results assessed by the Khalfayan functional score were excellent in two, good in one, and fair in four of these severely mangled upper extremities. None was amputated. The Mangled Extremity Severity Score has been shown to be unable to provide a reliable assessment for severe high-energy limb injuries surgically managed with the modular hybrid thin wire tubular external fixation system. This hybrid system is a very useful addition to the surgical armamentarium of orthopedic trauma surgeons. It both allows complex surgical reconstructions and reduces the incidence of deep infections in these heavily contaminated injuries. The hybrid circular (thin wire) external fixation system is very modular and may provide secure skeletal stabilization even in cases of severely comminuted juxta-articular fractures on both sides of the elbow joint (floating elbow) with severe damage to soft tissues. This fixation system allows individual fixation of forearm bone fractures, thus allowing the preservation of pronation-supination movements.

  1. Early experience with a novel nonmetallic cable in reconstructive hip surgery.

    PubMed

    Ting, Nicholas T; Wera, Glenn D; Levine, Brett R; Della Valle, Craig J

    2010-09-01

    Metallic wires and cables are commonly used in primary and revision THA for fixation of periprosthetic fractures and osteotomies of the greater trochanter. These systems provide secure fixation and high healing rates but fraying, third-body generation, accelerated wear of the bearing surface, and injury to the surgical team remain concerning. We determined the rate of cable failure, union, and complications associated with a novel, nonmetallic cerclage cable in periprosthetic fracture and osteotomy fixation during THA. We retrospectively reviewed 29 patients who had primary and revision THAs using nonmetallic cables. Indications for use included fixation of an extended trochanteric osteotomy, intraoperative fracture of the proximal femur, strut allograft fixation, and a Vancouver B1 periprosthetic fracture of the femur. All patients were evaluated clinically and radiographically immediately postoperatively, at 3 weeks, 6 weeks, 3 months, and then annually thereafter. The minimum followup was 13 months (mean, 21 months; range, 13-30 months). Two of the 29 patients (7%) developed a nonunion; all remaining osteotomies, fractures and allografts had healed at the time of most recent evaluation. Four patients (14%) dislocated postoperatively; two were treated successfully with closed reduction, while the other two required reoperation. We identified no evidence of breakage or other complications directly attributable to the cables. The nonmetallic periprosthetic cables used in this series provided adequate fixation to allow for both osteotomy and fracture healing. We did not observe any complications directly related to the cables. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  2. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome

    PubMed Central

    Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-01-01

    Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives better stability to fracture site and lessen the risk of implant failure. PMID:27042541

  3. Management of maxillofacial injuries in Iraq.

    PubMed

    Kummoona, Raja

    2011-09-01

    These clinical studies reflect the experience of the author in managing 673 patients treated during the last 8 years. All patients were treated in the Maxillofacial Unit, Surgical Specialties Hospital, Medical City, Baghdad, and in the author's private clinic. Included patients were 530 males and 143 females; patients' age ranged between 1 year and 75 years (mean, 38 y). Distribution of injuries was as follows: fracture of the mandible, 287 (42.64%); middle third injuries, 39 (5.79%); orbital injuries, 236 (35.07%; including 12 cases with cranioorbital injuries); injuries in children, 27 (4.0%); fracture of the zygoma, 52 (7.73%); and fracture of the nose, 40 (5.94%).Maxillofacial injuries in this study were classified as follows: (1) craniomaxillofacial with head injuries and cerebrospinal fluid leak; (2) fracture of the middle third including Le Fort I, II, and III and midline split in the face; (3) fracture of the mandible as an isolated injury or as part of a facial skeleton injury; and (4) isolated complex injuries of the zygoma, the orbital skeleton, and the nasoethmoidal region.The technique used for treating middle third injuries was external fixation either by halo frame (with vertical rods and cheek wires) or by box frame (using 4 external pins connected by rods) or internal fixation by suspending the middle third with internal wires (0.5 mm stainless steel) from the zygomatic process of the frontal bone beneath the zygomatic arch down the lower arch bar. Fractures of the mandible were treated by gunning splint with intermaxillary fixation (IMF) or with open reduction and fixation by stainless steel wire with IMF or by IMF screw or by an arch bar and IMF. Other fractures such as fracture of the orbit were treated by bone graft, sialastic, or lyophilized dura with open reduction. Fractures of the zygoma were treated by open reduction and fixation with stainless steel wire and bone graft or by reduction without fixation. Fractures of the nose were treated by reduction with straightening of the septum with a splint (lead splint or polythene) or by external splint with plaster of Paris. With the techniques used, results from managing these cases were satisfactory.

  4. Hybrid External Fixation for Arbeitsgemeinschaft für Osteosynthesefragen (AO) 43-C Tibial Plafond Fractures.

    PubMed

    Abd-Almageed, Emad; Marwan, Yousef; Esmaeel, Ali; Mallur, Amarnath; El-Alfy, Barakat

    2015-01-01

    Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 43-C tibial plafond/pilon fractures represent a challenge for the treating orthopedic surgeon. We assessed the outcomes of using hybrid external fixation for this fracture type. The present prospective cohort study was started in August 2009 and ended by July 2012. Thirty consecutive patients (mean age 37.4 ± 10.7 years) with a type C tibial plafond fracture who had presented to our tertiary care orthopedic hospital were included. Motor vehicle accidents and fall from height were the cause of the fracture in 14 (46.7%) and 13 (43.3%) patients, respectively. A type C3 fracture was present in 25 patients (83.3%), and type C1 and C2 fractures were present in 2 (6.7%) and 3 (10.0%) patients, respectively. Nine fractures (30.0%) were open. Hybrid external fixation was used for all fractures. All fractures were united; clinical healing was achieved by a mean of 18.1 ± 2.2 weeks postoperatively and radiologic healing at a mean of 18.9 ± 1.9 weeks. The fixator was removed at a mean of 20.4 ± 2.0 weeks postoperatively. At a mean follow-up point of 13.4 ± 2.6 months, the mean modified Mazur ankle score was 84.6 ± 10.4. It was not associated with wound classification (p = .256). The most commonly seen complication was ankle osteoarthritis (17 patients; 56.7%); however, it was mild in >50.0% of the affected patients. In conclusion, using hybrid external fixation for type C tibial plafond fractures resulted in good outcomes. However, this should be investigated further in studies with a higher level of evidence. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    PubMed

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  6. Comparison of nonsurgical treatment options in pediatric condylar fractures: rigid intermaxillary fixation versus using guiding elastic therapy.

    PubMed

    Tabrizi, Reza; Langner, Nicole Janine; Zamiri, Barbad; Aliabadi, Ehsan; Daneste, Hosein; Naghizade, Sina

    2013-05-01

    A prospective study was done to compare rigid intermaxillary fixation and guiding elastic for treatment of condylar fractures in pediatric patients. Sixty-one children younger than 12 years with condylar fractures were studied in 2 groups. Group 1 consisted of 31 patients who were treated with arch bar and intermaxillary fixation for 7 to 12 days, and group 2 consisted of 30 patients who were treated with arch bar and elastics without rigid intermaxillary fixation. Patients had minimal function during treatment time, which lasted 7 to 12 days. Evaluation of deviation on opening between both groups (groups 1 and 2) with a χ test did not show any relationship between them. Incidence of temporomandibular dysfunction signs was 25.8% in group 1 patients and 23.3% in group 2 patients. Comparison of temporomandibular dysfunction signs in both treatment groups did not show a statistically significant relationship. Our study showed the same results using guiding elastics as using rigid intermaxillary fixation in pediatric condylar fractures. Guiding elastic is more tolerable, and children have function during treatment.

  7. Acromioclavicular Joint Dislocation with Ipsilateral Mid Third Clavicle, Mid Shaft Humerus and Coracoid Process Fracture - A Case Report.

    PubMed

    Sharma, Naveen; Mandloi, Avinash; Agrawal, Ashish; Singh, Shailendra

    2016-01-01

    The clavicle, humerus and acromioclavicular (AC) joint separately are very commonly involved in traumatic injuries around the shoulder. Acromioclavicular joint dislocation with distal clavicle fracture is a well recognized entity in clinical practice. AC joint dislocation with mid shaft clavicle fracture is uncommon and only few cases have been reported in literature. However, to the best of our knowledge, this is the first case report to describe an acromioclavicular dislocation with ipsilateral mid shaft clavicle, mid shaft humerus and coracoid process fracture. Fractures of the humerus and clavicle along with the acromioclavicular joint dislocation were fixed at the same setting. A 65-year-old male met with a high velocity road traffic accident. Plain radiographs showed displaced mid third clavicle fracture with acromioclavicular joint dislocation with mid shaft humerus fracture. Surgical fixation was planned for humerus with interlocking nail, clavicle with locking plate and acromioclavicular joint with reconstruction of coracoclavicular ligaments. Intraoperatively, coracoid process was found to have a comminuted fracture. The operative plan had to be changed on table as coracoclavicular fixation was not possible. So acromioclavicular joint fixation was done using tension band wiring and the coracoclavicular ligament was repaired using a 2-0 ethibond. The comminuted coracoid fracture was managed conservatively. K wires were removed at 6 weeks. Early mobilization was started. In acromioclavicular joint injuries, clavicle must be evaluated for any injury. Although it is more commonly associated with distal clavicle fractures, it can be associated with middle third clavicle fractures. As plain radiographs, AP view are most of the times insufficient for viewing integrity of coracoid process, either special views like Stryker notch or CT scan may help in diagnosing such concealed injuries. When associated with fractures of the humerus and clavicle, anatomical restoration of acromioclavicular joint along with anatomical reduction and a rigid fixation of associated fractures is essential. Proper rehabilitation protocol is a must for achieving promising results. In our case, we were able to achieve a stable surgical fixation of both the fractures as well as AC joint, which enabled us to start early joint mobilization and rehabilitation.

  8. Increased wound complication with intramedullary screw fixation of clavicle fractures: Is it thermal necrosis?

    PubMed

    Domos, Peter; Tytherleigh-Strong, Graham; Van Rensburg, Lee

    2017-01-01

    Adult mid-shaft clavicle fractures are common injuries. For displaced fractures, open reduction with plate or intramedullary (IM) fixation is the widely used techniques. All methods have their own potential drawbacks, especially related to local soft tissue complications. There is little information about outcome and management of local wound complications after clavicle fracture fixations. Ninety-seven patients underwent open reduction and internal fixation, 17 were treated with IM screw fixation and 80 with plate fixation. Wound complication occurred in eight patients (8.2%) and rates differed significantly between IM and plate fixations (29.4% vs. 3.8%). Patients were assessed on average 58.3 months with visual analogue pain scores (VASs), Oxford Shoulder Score (OSS), and QuickDash (QD) score. Five patients had wound breakdown and three patients had wound erythema. In seven patients with stable fixation, it was possible to "dress and suppress" with average 3 weeks of oral antibiotics. One patient had unstable fixation and required longer antibiotic treatment with early screw removal. One patient developed a chronic discharging wound, requiring debridement and later plate removal. At final follow-up, all wounds remained healed, bony union was achieved in all. The average scores were: VAS 1, OSS 46, and QD 4.5. Good function with dry healed wound and united clavicle can be achieved. Further studies are required to investigate the difference in soft tissue complication rates, which may be due to the IM technique of retrograde drilling with a guide wire and due to aseptic thermal bone necrosis, rather than true infection.

  9. Percutaneous Instrumentation of a Complex Lumbar Spine Fracture with Bilateral Pedicle Dissociation: Case Report and Technical Note.

    PubMed

    Luther, Evan; Urakov, Timur; Vanni, Steven

    2018-06-11

     Complex traumatic lumbar spine fractures are difficult to manage and typically occur in younger patients. Surgical immobilization for unstable fractures is an accepted treatment but can lead to future adjacent-level disease. Furthermore, large variations in fracture morphology create significant difficulties when attempting fixation. Therefore, a surgical approach that considers both long-term outcomes and fracture type is of utmost importance. We present a novel technique for percutaneous fixation without interbody or posterolateral fusion in a young patient with bilateral pedicle dissociations and an acute-onset incomplete neurologic deficit.  A 20-year-old man involved in a motorcycle accident presented with unilateral right lower extremity paresis and sensory loss with intact rectal tone and no saddle anesthesia. Lumbar computed tomography (CT) demonstrated L2 and L3 fractures associated with bilateral pedicle dislocations. Lumbar magnetic resonance imaging showed draping of the conus medullaris/cauda equina anteriorly over the kyphotic deformity at L2 with minimal associated canal stenosis at L2 and L3. He was treated with emergent percutaneous fixation of the fracture segment without interbody or posterolateral fusion. Decompression was not performed because of the negligible amount of canal stenosis and high likelihood of cerebrospinal fluid leakage due to dural tears from the fractures. Surgical fixation of the L2 vertebra was achieved by cannulating the left pedicle with an oversized tap while holding the right pedicle in place with a normal tap and then driving screws into the left and right pedicles, respectively, thus reducing the free-floating fracture segment. At 18 months after surgery, a follow-up CT demonstrated good cortication across the prior pedicle fractures, and the instrumentation was removed without any obvious signs of instability or disruption of the alignment at the thoracolumbar junction.  We present a novel technique for percutaneous reduction and fixation of bilateral pedicle fractures with significant dissociation from the vertebral body, associated neural compression from the kyphotic deformity, and minimal spinal canal stenosis. Furthermore, we argue that early fixation and reduction of the fracture prevented irreversible neurologic compromise, and the absence of interbody or posterolateral fusion ultimately preserved the spinal mobility of the patient once the hardware was removed. Georg Thieme Verlag KG Stuttgart · New York.

  10. Unilateral lag screw fixation of isolated non-union atlas lateral mass fracture: a new technical note.

    PubMed

    Farrokhi, Majid Reza; Kiani, Arash; Rezaei, Hamid

    2018-01-15

    We describe a novel and new technique of posterior unilateral lag screw fixation of non-union atlas lateral mass fracture. A 46-year-old man presented with cervical pain and tenderness after a vehicle turn over accident and he was diagnosed to have left atlas lateral mass fracture. He was initially treated by immobilization using Minerva orthosis. About 2 months later, he developed severe neck pain and limitation of motion and thus he was scheduled for operation due to non-union atlas lateral mass fracture. A 28 mm lag screw was inserted under anterior-posterior and lateral fluoroscopic views. The entrance point was at the dorsal aspect of left atlas posterior arc at its junction to the lateral mass, and by using the trajectory of 10 degrees medial and 22 degrees cephalad fracture reduction was achieved. Unilateral lag screw fixation of atlas fractures is an appropriate, safe and effective surgical technique for the management of unilateral atlas fractures.

  11. Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.

    PubMed

    Christopher, Scott A; Kim, Stanley E; Roe, Simon; Pozzi, Antonio

    2016-08-01

    Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with press-fit cementless stems. Peak torsional load to failure was compared between femora without adjunctive fixation and femora receiving a 1 mm double loop cerclage wire placed proximally to the lesser trochanter. Femora treated with adjunctive cerclage wire fixation failed at 20% greater peak torque (P = 0.0001). In conclusion, a double loop cerclage wire may aid in the prevention of periprosthetic fractures associated with press-fit cementless femoral stems. Copyright © 2016. Published by Elsevier Ltd.

  12. The use of resorbable hardware for fixation of pediatric mandible fracture. Case report.

    PubMed

    Poore, Matthew C; Penna, Kevin J

    2008-01-01

    The diagnosis and management of mandible fractures in the pediatric patient population can pose multiple challenges to the oral and maxillofacial surgeon. Resorbable plates and screws for fixation in this population are both well tolerated and effective. They enable realignment and stable positioning of rapidly healing fracture segments, while obviating any potential impediments to long-term metal retention.

  13. Assessment of carbon fibre composite fracture fixation plate using finite element analysis.

    PubMed

    Saidpour, Seyed H

    2006-07-01

    In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress shielding in the layer of bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. In this study a novel forearm internal fracture fixation plate made from short carbon fibre reinforced plastic (CFRP) was used in an attempt to address the problem. Accordingly, it has been possible to analyse the stress distribution in the composite plates using finite-element modelling. A three-dimensional, quarter-symmetric finite element model was generated for the plate system. The stress state in the underlying bone was examined for several loading conditions. Based on the analytical results the composite plate system is likely to reduce stress-shielding effects at the fracture site when subjected to bending and torsional loads. The design of the plate was further optimised by reducing the width around the innermost holes.

  14. Randomized prospective study of olecranon fracture fixation: cable pin system versus tension band wiring.

    PubMed

    Liu, Q-H; Fu, Z-G; Zhou, J-L; Lu, T; Liu, T; Shan, L; Liu, Y; Bai, L

    2012-01-01

    This prospective, randomized study compared the effectiveness of the cable pin system (CPS) versus tension band wiring (TBW) for olecranon fracture fixation. Patients with acute transverse or slight oblique olecranon fractures were randomly divided into two groups: one fixed by CPS and the other by TBW. Clinical outcome data were collected and analysed following a mean duration of 21 months. The mean ± SD fracture healing time was significantly shorter in the CPS group (n = 30; 9.73 ± 2.02 weeks) compared with the TBW group (n = 32; 11.13 ± 2.21 weeks). One patient in the CPS group and seven patients in the TBW group experienced postoperative complications; this difference was statistically significant. The mean ± SD Mayo Elbow Performance Score in the CPS group was significantly higher (88.67 ± 6.42) than that in the TBW group (80.78 ± 11.99). Logistic regression analysis showed an association between fixation method and fracture healing time, complications and elbow function. Internal fixation by CPS is an effective method for olecranon fracture and is associated with a shorter healing time, fewer complications and better function than TBW.

  15. Stress Fractures of Tibia Treated with Ilizarov External Fixator.

    PubMed

    Górski, Radosław; Żarek, Sławomir; Modzelewski, Piotr; Górski, Ryszard; Małdyk, Paweł

    2016-08-30

    Stress fractures are the result of cyclic loading of the bone, which gradually becomes damaged. Most often they are treated by rest or plaster cast and, in rare cases, by internal fixation. There is little published data on initial reposition followed by stabilization with the Ilizarov apparatus in such fractures. Six patients were treated with an external fixator according to the Ilizarov method for a stress fracture of the tibia between 2007 and 2015. Three patients were initially treated conservatively. Due to increasing tibial deformation, they were qualified for surgical treatment with external stabilization. In the other patients, surgery was the first-line treatment. All patients demonstrated risk factors for a stress fracture. After the surgery, they fully loaded the operated limb. No patient developed malunion, nonunion, infection or venous thrombosis. The average time from the first operation to the removal of the external fixator was 19 weeks. Radiographic and clinical outcomes were satisfactory in all patients. 1. The Ilizarov method allows for successful stabilization of stress fractures of the tibia. 2. It may be a good alternative to internal stabilization, especially in patients with multiple comorbidities which affect bone quality and may impair soft tissue healing.

  16. Displaced intra-articular calcaneal fractures.

    PubMed

    Bajammal, Sohail; Tornetta, Paul; Sanders, David; Bhandari, Mohit

    2005-01-01

    Calcaneal fractures comprise 1 to 2 percent of all fractures. Approximately 75% of calcaneal fractures are intra-articular. The management of intra-articular calcaneal fractures remains controversial. Nonoperative treatment options include elevation, ice, early mobilization, and cyclic compression of the plantar arch. Operative treatment options include closed reduction and percutaneous pin fixation, open reduction and internal fixation, and arthrodesis. The effect of operative versus nonoperative treatment has been the focus of several comparative studies. This study was designed to determine the effect of operative treatment compared with nonoperative treatment on the rate of union, complications, and functional outcome after intra-articular calcaneal fracture in adults.

  17. Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) protocol: a pragmatic multi-centre randomised controlled trial of cast treatment versus surgical fixation for the treatment of bi-cortical, minimally displaced fractures of the scaphoid waist in adults.

    PubMed

    Dias, Joseph; Brealey, Stephen; Choudhary, Surabhi; Cook, Liz; Costa, Matthew; Fairhurst, Caroline; Hewitt, Catherine; Hodgson, Stephen; Jefferson, Laura; Jeyapalan, Kanagaratnam; Keding, Ada; Leighton, Paul; Rangan, Amar; Richardson, Gerry; Rothery, Claire; Taub, Nicholas; Thompson, John; Torgerson, David

    2016-06-04

    A scaphoid fracture is the most common type of carpal fracture affecting young active people. The optimal management of this fracture is uncertain. When treated with a cast, 88 to 90 % of these fractures unite; however, for the remaining 10-12 % the non-union almost invariably leads to arthritis. The alternative is surgery to fix the scaphoid with a screw at the outset. We will conduct a randomised controlled trial (RCT) of 438 adult patients with a "clear" and "bicortical" scaphoid waist fracture on plain radiographs to evaluate the clinical effectiveness and cost-effectiveness of plaster cast treatment (with fixation of those that fail to unite) versus early surgical fixation. The plaster cast treatment will be immobilisation in a below elbow cast for 6 to 10 weeks followed by mobilisation. If non-union is confirmed on plain radiographs and/or Computerised Tomogram at 6 to 12 weeks, then urgent surgical fixation will be performed. This is being compared with immediate surgical fixation with surgeons using their preferred technique and implant. These treatments will be undertaken in trauma units across the United Kingdom. The primary outcome and end-point will be the Patient Rated Wrist Evaluation (a patient self-reported assessment of wrist pain and function) at 52 weeks and also measured at 6, 12, 26 weeks and 5 years. Secondary outcomes include an assessment of radiological union of the fracture; quality of life; recovery of wrist range and strength; and complications. We will also qualitatively investigate patient experiences of their treatment. Scaphoid fractures are an important public health problem as they predominantly affect young active individuals in the more productive working years of their lives. Non-union, if untreated, can lead to arthritis which can disable patients at a very young age. There is a rapidly increasing trend for immediate surgical fixation of these fractures but there is insufficient evidence from existing RCTs to support this. The SWIFFT Trial is a rigorously designed and adequately powered study which aims to contribute to the evidence-base to inform clinical decisions for the treatment of this common fracture in adults. The trial is registered with the International Standard Randomised Controlled Trial Register ( ISRCTN67901257 ). Date registration assigned was 13/02/2013.

  18. Influence of fracture geometry on bone healing under locking plate fixations: A comparison between oblique and transverse tibial fractures.

    PubMed

    Miramini, Saeed; Zhang, Lihai; Richardson, Martin; Mendis, Priyan; Ebeling, Peter R

    2016-10-01

    Mechano-regulation plays a crucial role in bone healing and involves complex cellular events. In this study, we investigate the change of mechanical microenvironment of stem cells within early fracture callus as a result of the change of fracture obliquity, gap size and fixation configuration using mechanical testing in conjunction with computational modelling. The research outcomes show that angle of obliquity (θ) has significant effects on interfragmentary movement (IFM) which influences mechanical microenvironment of the callus cells. Axial IFM at near cortex of fracture decreases with θ, while shear IFM significantly increases with θ. While a large θ can increase shear IFM by four-fold compared to transverse fracture, it also result in the tension-stress effect at near cortex of fracture callus. In addition, mechanical stimuli for cell differentiation within the callus are found to be strongly negatively correlated to angle of obliquity and gap size. It is also shown that a relatively flexible fixation could enhance callus formation in presence of a large gap but could lead to excessive callus strain and interstitial fluid flow when a small transverse fracture gap is present. In conclusion, there appears to be an optimal fixation configuration for a given angle of obliquity and gap size. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Management of Open Tibial Shaft Fractures: Does the Timing of Surgery Affect Outcomes?

    PubMed

    Duyos, Oscar A; Beaton-Comulada, David; Davila-Parrilla, Ariel; Perez-Lopez, Jose Carlos; Ortiz, Krystal; Foy-Parrilla, Christian; Lopez-Gonzalez, Francisco

    2017-03-01

    Open tibial shaft fractures require emergent care. Treatment with intravenous antibiotics and fracture débridement within 6 to 24 hours is recommended. Few studies have examined outcomes when surgical treatment is performed >24 hours after occurrence of the fracture. This retrospective study included 227 patients aged ≥18 years with isolated open tibial shaft fractures in whom the time to initial débridement was >24 hours. The statistical analysis was based on time from injury to surgical débridement, Gustilo-Anderson classification, method of fixation, union status, and infection status. Fractures débrided within 24 to 48 hours and 48 to 96 hours after injury did not show a statistically significant difference in terms of infection rates (P = 0.984). External fixation showed significantly greater infection rates (P = 0.044) and nonunion rates (P = 0.001) compared with intramedullary nailing. Open tibial shaft fractures should be débrided within 24 hours after injury. Our data indicate that after the 24-hour period and up to 4 days, the risk of infection remains relatively constant independent of the time to débridement. Patients treated with external fixation had more complications than did patients treated with other methods of fixation. Primary reamed intramedullary nailing appears to be a reasonable option for the management of Gustilo-Anderson types 1 and 2 open tibial shaft fractures. Level III retrospective study.

  20. Intramedullary Percutaneous Fixation of Extra-Articular Proximal and Middle Phalanx Fractures.

    PubMed

    Jovanovic, Nebojsa; Aldlyami, Ehab; Saraj, Basem; Fm Seidam, Mohamed; Badawi, Hamed; Shaat, Ahmed; Alawadi, Khalid; Dodakundi, Chaitanya

    2018-06-01

    Multiple methods have been described for treating unstable proximal and middle phalangeal fractures. Irrespective of using an open or closed technique of fixation, stiffness and extensor lag at the proximal/distal interphalangeal joint almost always occur. This issue can be avoided by allowing the patients to mobilize the fingers out of plaster or splint as early as possible from the day of surgery. We describe a technique of intramedullary percutaneous fixation of extra-articular proximal and middle phalanx fractures allowing immediate mobilization of fingers, concurrent stabilization with progressive healing and thus preventing such complications.

  1. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    PubMed

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  2. Temporary Stabilization with External Fixator in 'Tripolar' Configuration in Two Steps Treatment of Tibial Pilon Fractures.

    PubMed

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation. Temporary stabilization with external fixator in 'tripolar' configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases.

  3. Implant-supported rehabilitation after treatment of atrophic mandibular fractures: report of two cases.

    PubMed

    Oliveira, Leandro Benetti de; Gabrielli, Marisa Aparecida Cabrini; Gabrielli, Mario Francisco Real; Pereira-Filho, Valfrido Antonio Pereira

    2015-12-01

    The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.

  4. A Novel Technique for Closed Reduction and Fixation of Paediatric Calcaneal Fracture Dislocation Injuries

    PubMed Central

    Faroug, Radwane; Stirling, Paul; Ali, Farhan

    2013-01-01

    Paediatric calcaneal fractures are rare injuries usually managed conservatively or with open reduction and internal fixation (ORIF). Closed reduction was previously thought to be impossible, and very few cases are reported in the literature. We report a new technique for closed reduction using Ilizarov half-rings. We report successful closed reduction and screwless fixation of an extra-articular calcaneal fracture dislocation in a 7-year-old boy. Reduction was achieved using two Ilizarov half-ring frames arranged perpendicular to each other, enabling simultaneous application of longitudinal and rotational traction. Anatomical reduction was achieved with restored angles of Bohler and Gissane. Two K-wires were the definitive fixation. Bony union with good functional outcome and minimal pain was achieved at eight-weeks follow up. ORIF of calcaneal fractures provides good functional outcome but is associated with high rates of malunion and postoperative pain. Preservation of the unique soft tissue envelope surrounding the calcaneus reduces the risk of infection. Closed reduction prevents distortion of these tissues and may lead to faster healing and mobilisation. Closed reduction and screwless fixation of paediatric calcaneal fractures is an achievable management option. Our technique has preserved the soft tissue envelope surrounding the calcaneus, has avoided retained metalwork related complications, and has resulted in a good functional outcome. PMID:23819090

  5. Fracture healing in mice under controlled rigid and flexible conditions using an adjustable external fixator.

    PubMed

    Röntgen, Viktoria; Blakytny, Robert; Matthys, Romano; Landauer, Mario; Wehner, Tim; Göckelmann, Melanie; Jermendy, Philipp; Amling, Michael; Schinke, Thorsten; Claes, Lutz; Ignatius, Anita

    2010-11-01

    Mice are increasingly used to investigate mechanobiology in fracture healing. The need exists for standardized models allowing for adjustment of the mechanical conditions in the fracture gap. We introduced such a model using rigid and flexible external fixators with considerably different stiffness (axial stiffnesses of 18.1 and 0.82 N/mm, respectively). Both fixators were used to stabilize a 0.5 mm osteotomy gap in the femur of C57BL/6 mice (each n = 8). Three-point bending tests, µCT, and histomorphometry demonstrated a different healing pattern after 21 days. Both fixations induced callus formation with a mixture of intramembranous and enchondral ossification. Under flexible conditions, the bending stiffness of the callus was significantly reduced, and a larger but qualitatively inferior callus with a significantly lower fraction of bone but a higher fraction of cartilage and soft tissue was formed. Monitoring of the animal movement and the ground reaction forces demonstrated physiological loading with no significant differences between the groups, suggesting that the differences in healing were not based on a different loading behavior. In summary, flexible external fracture fixation of the mouse femur led to delayed fracture healing in comparison to a more rigid situation. © 2010 Orthopaedic Research Society.

  6. Stabilization of an acetabular fracture with cables for acute total hip arthroplasty.

    PubMed

    Mears, D C; Shirahama, M

    1998-01-01

    A critical stage of total hip arthroplasty for an acute acetabular fracture where extensive comminution, impaction, and osteopenia thwart the application of conventional open or closed methods, especially in the elderly, is stable fixation of the acetabulum. The use of 2-mm braided cables permits effective immobilization of the fracture for use in conjunction with a hybrid arthroplasty. The method is consistent with the use of a conventional arthroplastic incision and is suitable for other applications including the fixation of periprosthetic fractures, bulk allografts, and conventional acetabular fractures.

  7. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis.

    PubMed

    Zhao, Y; Zhang, S; Sun, T; Wang, D; Lian, W; Tan, J; Zou, D; Zhao, Y

    2013-09-01

    To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications. A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared. The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1. In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended than that in S1. Experimental study Level III. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  8. The clinical application of absorbable intramedullary nail and claw plate on treating multiple rib fractures.

    PubMed

    Chai, X; Lin, Q; Ruan, Z; Zheng, J; Zhou, J; Zhang, J

    2013-08-01

    The absorption intramedullary nail and claw plate indications and efficacy were investigated in the treatment of a life-threatening multiple rib fractures. A retrospective analysis of 248 surgically treated rib fracture patients was performed who admitted to our hospital from March 2007 to December 2012. Intramedullary nailing was performed in 28 cases, a claw-type bone plate was fixed in 141 cases, and a combination of both was fixed in 79 cases. All internal fixation patients were clinically cured except 1 patient died 14 days after a massive pulmonary embolism. The patients with flail chest and floating chest wall causing respiratory and circulatory disorders were promptly corrected. Routine follow-up was from 1 to 2 years, displaced fractures were in 2 cases, and there were 11 cases of internal fixation and extraction. Internal fixation is a simple and reliable method for the treatment of multiple rib fractures. Both internal fixation materials have their pros and cons but the claw bone plate is more robust. The actual selection of appropriate treatment options helps to improve the treatment efficacy.

  9. Intramedullary nail fixation versus locking plate fixation for adults with a fracture of the distal tibia: the UK FixDT RCT.

    PubMed

    Costa, Matthew L; Achten, Juul; Hennings, Susie; Boota, Nafisa; Griffin, James; Petrou, Stavros; Maredza, Mandy; Dritsaki, Melina; Wood, Thomas; Masters, James; Pallister, Ian; Lamb, Sarah E; Parsons, Nick R

    2018-05-01

    The best treatment for fractures of the distal tibia remains controversial. Most of these fractures require surgical fixation, but the outcomes are unpredictable and complications are common. To assess disability, quality of life, complications and resource use in patients treated with intramedullary (IM) nail fixation versus locking plate fixation in the 12 months following a fracture of the distal tibia. This was a multicentre randomised trial. The trial was conducted in 28 UK acute trauma centres from April 2013 to final follow-up in February 2017. In total, 321 adult patients were recruited. Participants were excluded if they had open fractures, fractures involving the ankle joint, contraindication to nailing or inability to complete questionnaires. IM nail fixation ( n  = 161), in which a metal rod is inserted into the hollow centre of the tibia, versus locking plate fixation ( n  = 160), in which a plate is attached to the surface of the tibia with fixed-angle screws. The primary outcome measure was the Disability Rating Index (DRI) score, which ranges from 0 points (no disability) to 100 points (complete disability), at 6 months with a minimum clinically important difference of 8 points. The DRI score was also collected at 3 and 12 months. The secondary outcomes were the Olerud-Molander Ankle Score (OMAS), quality of life as measured using EuroQol-5 Dimensions (EQ-5D), complications such as infection, and further surgery. Resource use was collected to inform the health economic evaluation. Participants had a mean age of 45 years (standard deviation 16.2 years), were predominantly male (61%, 197/321) and had experienced traumatic injury after a fall (69%, 223/321). There was no statistically significant difference in DRI score at 6 months [IM nail fixation group, mean 29.8 points, 95% confidence interval (CI) 26.1 to 33.7 points; locking plate group, mean 33.8 points, 95% CI 29.7 to 37.9 points; adjusted difference, 4.0 points, 95% CI -1.0 to 9.0 points; p  = 0.11]. There was a statistically significant difference in DRI score at 3 months in favour of IM nail fixation (IM nail fixation group, mean 44.2 points, 95% CI 40.8 to 47.6 points; locking plate group, mean 52.6 points, 95% CI 49.3 to 55.9 points; adjusted difference 8.8 points, 95% CI 4.3 to 13.2 points; p  < 0.001), but not at 12 months (IM nail fixation group, mean 23.1 points, 95% CI 18.9 to 27.2 points; locking plate group, 24.0 points, 95% CI 19.7 to 28.3 points; adjusted difference 1.9 points, 95% CI -3.2 to 6.9 points; p  = 0.47). Secondary outcomes showed the same pattern, including a statistically significant difference in mean OMAS and EQ-5D scores at 3 and 6 months in favour of IM nail fixation. There were no statistically significant differences in complications, including the number of postoperative infections (13% in the locking plate group and 9% in the IM nail fixation group). Further surgery was more common in the locking plate group (12% in locking plate group and 8% in IM nail fixation group at 12 months). The economic evaluation showed that IM nail fixation provided a slightly higher quality of life in the 12 months after injury and at lower cost and, therefore, it was cost-effective compared with locking plate fixation. The probability of cost-effectiveness for IM nail fixation exceeded 90%, regardless of the value of the cost-effectiveness threshold. As wound dressings after surgery are clearly visible, it was not possible to blind the patients to their treatment allocation. This evidence does not apply to intra-articular (pilon) fractures of the distal tibia. Among adults with an acute fracture of the distal tibia who were randomised to IM nail fixation or locking plate fixation, there were similar disability ratings at 6 months. However, recovery across all outcomes was faster in the IM nail fixation group and costs were lower. The potential benefit of IM nail fixation in several other fractures requires investigation. Research is also required into the role of adjuvant treatment and different rehabilitation strategies to accelerate recovery following a fracture of the tibia and other long-bone fractures in the lower limb. The patients in this trial will remain in longer-term follow-up. Current Controlled Trials ISRCTN99771224 and UKCRN 13761. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 22, No. 25. See the NIHR Journals Library website for further project information.

  10. [ANALYSIS OF CLINICAL EFFECT IN SURGICAL TREATMENT OF Maisonneuve FRACTURE].

    PubMed

    Zhang, Zhiwen; Cai, Xianhua; Wei, Shijun; Liu, Ximing

    2015-03-01

    To investigate the operative method and short-term effectiveness in the surgical treatment of Maisonneuve fracture. Between January 2010 and February 2013, 23 patients with Maisonneuve fracture were treated. There were 14 males and 9 females with an average age of 40.3 years (range, 30-68 years). The causes of injuries were falling injury in 11 patients, sports related injury in 5 patients, traffic accident injury in 4 patients, and falling injury from height in 3 patients. The interval between injury and operation was 7-10 days (mean, 8.5 days). All of fractures were closed. Three patients had combined injury of deltoid ligament. The surgical procedures included surgical reduction and fixation of medial malleolus fracture and posterior malleolus fracture, repair of the deltoid ligament with ground anchor suture, and fixation of the disrupted distal tibiofibular syndesmosis. All incisions achieved primary healing, no postoperative complications such as infection occurred. Twenty-one patients were followed up 24-36 months (mean, 26.5 months). No patients complained of pain, tenderness, and obvious swelling of the ankle. At 3-6 months (mean, 4.6 months) after operation, X-ray films showed bony union of fractures and normal mortises in 21 patients. And no traumatic arthritis was observed with reliable fixation. The range of motion of ankle dorsi flexion and plantar flexion was 30-40 degrees) (mean, 34.5 degrees) Baird-Jackson anide functional score was 85-100 (mean, 94); 16 cases were rated as excellent, 4 as good, and 1 as fair with an excellent and good rate of 95.2%. Surgical treatments of Maisonneuve fracture include surgical reduction and fixation of the medial malleolus and posterior malleolus, repair of the deltoid ligament and fixation of the disrupted distal tibiofibular syndesmosis, and good effectiveness can be achieved.

  11. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    PubMed

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted tibial pilon fracture reliably healed and restored acceptable function in this highly selective patient group. Ring external fixation may be a useful adjunct to internal fixation, and this concept should be further studied. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  12. Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.

    PubMed

    Madey, Steven M; Tsai, Stanley; Fitzpatrick, Daniel C; Earley, Kathleen; Lutsch, Michael; Bottlang, Michael

    2017-01-01

    Rigid locked plating constructs can suppress fracture healing by inhibiting interfragmentary motion required to stimulate natural bone healing by callus formation. Dynamic fixation with active locking plates reduces construct stiffness, enables controlled interfragmentary motion, and has been shown to induce faster and stronger bone healing in vivo compared to rigid locking plates. This prospective observational study represents the first clinical use of active locking plates. It documents our early clinical experience with active plates for stabilization of humeral shaft fractures to assess their durability and understand potential complications. Eleven consecutive patients with humeral shaft fractures (AO/OTA types 12 A-C) were prospectively enrolled at a level I and a level II trauma center. Fractures were stabilized by using active locking plates without supplemental bone graft or bone morphogenic proteins. The screw holes of active locking plates are elastically suspended in elastomer envelopes inside the plate, enabling up to 1.5 mm of controlled interfragmentary motion. Progression of fracture healing and integrity of implant fixation was assessed radiographically at 3, 6, 12, and 24 weeks post surgery. Patient-reported functional outcome measures were obtained at 6, 12, and 24 weeks post surgery. The primary endpoint of this study was plate durability in absence of plate bending or breakage, or failure of the elastically suspended locking hole mechanism. Secondary endpoints included fracture healing, complications requiring revision surgery, and functional outcome scores. The eleven patients had six simple AO/ OTA type 12A fractures, three wedge type 12B fractures, and two comminuted type 12C fracture, including one open fracture. All active locking plates endured the 6-month loading period without any signs of fatigue or failure. Ten of eleven fractures healed at 10.9 ± 5.2 weeks, as evident by bridging callus and pain-free function. One fracture required revision surgery 37 weeks post surgery due to late fixation failure at the screwbone interface in the presence of a atrophic delayed union. The average Disability of the Arm, Shoulder and Hand (DASH) score improved from 31 ± 22 at week 6 to 13 ± 15 by week 24, approaching that of the normal, healthy population (DASH = 10.1). By week 12, the difference between Constant shoulder scores, expressed as the difference between the affected and contralateral arm (8 ± 8), was considered excellent. By week 24, the SF-12 physical health score (44 ± 9) and mental health score (48 ± 11) approached the mean value of 50 that represents the norm for the general U.S. population. Absence of failure of the plate and locking holes suggests that dynamic fixation of humeral shaft fractures with active plates provides safe and effective fixation. Moreover, early callus bridging and excellent functional outcome scores suggest that dynamic fixation with active locking plates may promote increased fracture healing over standard locked plating.

  13. Is Bone Grafting Necessary in the Treatment of Malunited Distal Radius Fractures?

    PubMed Central

    Disseldorp, Dominique J. G.; Poeze, Martijn; Hannemann, Pascal F. W.; Brink, Peter R. G.

    2015-01-01

    Background Open wedge osteotomy with bone grafting and plate fixation is the standard procedure for the correction of malunited distal radius fractures. Bone grafts are used to increase structural stability and to enhance new bone formation. However, bone grafts are also associated with donor site morbidity, delayed union at bone–graft interfaces, size mismatch between graft and osteotomy defect, and additional operation time. Purpose The goal of this study was to assess bone healing and secondary fracture displacement in the treatment of malunited distal radius fractures without the use of bone grafting. Methods Between January 1993 and December 2013, 132 corrective osteotomies and plate fixations without bone grafting were performed for malunited distal radius fractures. The minimum follow-up time was 12 months. Primary study outcomes were time to complete bone healing and secondary fracture displacement. Preoperative and postoperative radiographs during follow-up were compared with each other, as well as with radiographs of the uninjured side. Results All 132 osteotomies healed. In two cases (1.5%), healing took more than 4 months, but reinterventions were not necessary. No cases of secondary fracture displacement or hardware failure were observed. Significant improvements in all radiographic parameters were shown after corrective osteotomy and plate fixation. Conclusion This study shows that bone grafts are not required for bone healing and prevention of secondary fracture displacement after corrective osteotomy and plate fixation of malunited distal radius fractures. Level of evidence Therapeutic, level IV, case series with no comparison group PMID:26261748

  14. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    PubMed

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  15. Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures.

    PubMed

    Takeba, Jun; Umakoshi, Kensuke; Kikuchi, Satoshi; Matsumoto, Hironori; Annen, Suguru; Moriyama, Naoki; Nakabayashi, Yuki; Sato, Norio; Aibiki, Mayuki

    2018-04-01

    Screw fixation for unstable pelvic ring fractures is generally performed using the C-arm. However, some studies reported erroneous piercing with screws, nerve injuries, and vessel injuries. Recent studies have reported the efficacy of screw fixations using navigation systems. The purpose of this retrospective study was to investigate the accuracy of screw fixation using the O-arm ® imaging system and StealthStation ® navigation system for unstable pelvic ring fractures. The participants were 10 patients with unstable pelvic ring fractures, who underwent screw fixations using the O-arm StealthStation navigation system (nine cases with iliosacral screw and one case with lateral compression screw). We investigated operation duration, bleeding during operation, the presence of complications during operation, and the presence of cortical bone perforation by the screws based on postoperative CT scan images. We also measured the difference in screw tip positions between intraoperative navigation screen shot images and postoperative CT scan images. The average operation duration was 71 min, average bleeding was 12 ml, and there were no nerve or vessel injuries during the operation. There was no cortical bone perforation by the screws. The average difference between intraoperative navigation images and postoperative CT images was 2.5 ± 0.9 mm, for all 18 screws used in this study. Our results suggest that the O-arm StealthStation navigation system provides accurate screw fixation for unstable pelvic ring fractures.

  16. Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures

    PubMed Central

    2014-01-01

    Background Hip fractures are a common type of fragility fracture that afflict 293,000 Americans (over 5,000 per week) and 35,000 Canadians (over 670 per week) annually. Despite the large population impact the optimal fixation technique for low energy femoral neck fractures remains controversial. The primary objective of the FAITH study is to assess the impact of cancellous screw fixation versus sliding hip screws on rates of revision surgery at 24 months in individuals with femoral neck fractures. The secondary objective is to determine the impact on health-related quality of life, functional outcomes, health state utilities, fracture healing, mortality and fracture-related adverse events. Methods/Design FAITH is a multi-centre, multi-national randomized controlled trial utilizing minimization to determine patient allocation. Surgeons in North America, Europe, Australia, and Asia will recruit a total of at least 1,000 patients with low-energy femoral neck fractures. Using central randomization, patients will be allocated to receive surgical treatment with cancellous screws or a sliding hip screw. Patient outcomes will be assessed at one week (baseline), 10 weeks, 6, 12, 18, and 24 months post initial fixation. We will independently adjudicate revision surgery and complications within 24 months of the initial fixation. Outcome analysis will be performed using a Cox proportional hazards model and likelihood ratio test. Discussion This study represents major international efforts to definitively resolve the treatment of low-energy femoral neck fractures. This trial will not only change current Orthopaedic practice, but will also set a benchmark for the conduct of future Orthopaedic trials. Trial registration The FAITH trial is registered at ClinicalTrials.gov (Identifier NCT00761813). PMID:24965132

  17. Comparison of surgical techniques of 111 medial malleolar fractures classified by fracture geometry.

    PubMed

    Ebraheim, Nabil A; Ludwig, Todd; Weston, John T; Carroll, Trevor; Liu, Jiayong

    2014-05-01

    Evaluation of operative techniques used for medial malleolar fractures by classifying fracture geometry has not been well documented. One hundred eleven patients with medial malleolar fractures (transverse n = 63, oblique n = 29, vertical n = 7, comminuted n = 12) were included in this study. Seventy-two patients had complicating comorbidities. All patients were treated with buttress plate, lag screw, tension band, or K-wire fixation. Treatment outcomes were evaluated on the basis of radiological outcome (union, malunion, delayed union, or nonunion), need for operative revision, presence of postoperative complications, and AOFAS Ankle-Hindfoot score. For transverse fractures, tension band fixation showed the highest rate of union (79%), highest average AOFAS score (86), lowest revision rate (5%), and lowest complication rate (16%). For oblique fractures, lag screws showed the highest rate of union (71%), highest average AOFAS score (80), lowest revision rate (19%), and lowest complication rate (33%) of the commonly used fixation techniques. For vertical fractures, buttress plating was used in every case but 1, achieving union (whether normal or delayed) in all cases with an average AOFAS score of 84, no revisions, and a 17% complication rate. Comminuted fractures had relatively poor outcomes regardless of fixation method. The results of this study suggest that both tension bands and lag screws result in similar rates of union for transverse fractures of the medial malleolus, but that tension band constructs are associated with less need for revision surgery and fewer complications. In addition, our data demonstrate that oblique fractures were most effectively treated with lag screws and that vertical fractures attained superior outcomes with buttress plating. Level III, retrospective comparative series.

  18. Plating of patella fractures: techniques and outcomes.

    PubMed

    Taylor, Benjamin C; Mehta, Sanjay; Castaneda, Joaquin; French, Bruce G; Blanchard, Chris

    2014-09-01

    Operative treatment of displaced patella fractures with tension band fixation remains the gold standard, but is associated with a significant rate of complications and symptomatic implants. Despite the evolution of tension band fixation to include cannulated screws, surprisingly little other development has been made to improve overall patient outcomes. In this article, we present the techniques and outcomes of patella plating for displaced patella fractures and patella nonunions.

  19. Percutaneous internal fixation of proximal fifth metatarsal jones fractures (Zones II and III) with Charlotte Carolina screw and bone marrow aspirate concentrate: an outcome study in athletes.

    PubMed

    Murawski, Christopher D; Kennedy, John G

    2011-06-01

    Internal fixation is a popular first-line treatment method for proximal fifth metatarsal Jones fractures in athletes; however, nonunions and screw breakage can occur, in part because of nonspecific fixation hardware and poor blood supply. To report the results from 26 patients who underwent percutaneous internal fixation with a specialized screw system of a proximal fifth metatarsal Jones fracture (zones II and III) and bone marrow aspirate concentrate. Case series; Level of evidence, 4. Percutaneous internal fixation for a proximal fifth metatarsal Jones fracture (zones II and III) was performed on 26 athletic patients (mean age, 27.47 years; range, 18-47). All patients were competing at some level of sport and were assessed preoperatively and postoperatively using the Foot and Ankle Outcome Score and SF-12 outcome scores. The mean follow-up time was 20.62 months (range, 12-28). Of the 26 fractures, 17 were traditional zone II Jones fractures, and the remaining 9 were zone III proximal diaphyseal fractures. The mean Foot and Ankle Outcome Score significantly increased, from 51.15 points preoperatively (range, 14-69) to 90.91 at final follow-up (range, 71-100; P < .01). The mean physical component of the SF-12 score significantly improved, from 25.69 points preoperatively (range, 6-39) to 54.62 at final follow-up (range, 32-62; P < .01). The mean mental component of the SF-12 score also significantly improved, from 28.20 points preoperatively (range, 14-45) to 58.41 at final follow-up (range, 36-67; P < .01). The mean time to fracture healing on standard radiographs was 5 weeks after surgery (range, 4-24). Two patients did not return to their previous levels of sporting activity. One patient experienced a delayed union, and 1 healed but later refractured. Percutaneous internal fixation of proximal fifth metatarsal Jones fractures, with a Charlotte Carolina screw and bone marrow aspirate concentrate, provides more predictable results while permitting athletes a return to sport at their previous levels of competition, with few complications.

  20. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.

    PubMed

    Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo

    2017-06-01

    High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the occurrence of infection. Staged MIPO for proximal tibial fractures with acute compartment syndrome may achieve satisfactory bony union and functional results, while decreasing deep infections and soft tissue complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture.

    PubMed

    Hung, Chun-Chi; Li, Yuan-Ta; Chou, Yu-Ching; Chen, Jia-En; Wu, Chia-Chun; Shen, Hsain-Chung; Yeh, Tsu-Te

    2018-05-03

    Treating pelvic fractures remains a challenging task for orthopaedic surgeons. We aimed to evaluate the feasibility, accuracy, and effectiveness of three-dimensional (3D) printing technology and computer-assisted virtual surgery for pre-operative planning in anterior ring fractures of the pelvis. We hypothesized that using 3D printing models would reduce operation time and significantly improve the surgical outcomes of pelvic fracture repair. We retrospectively reviewed the records of 30 patients with pelvic fractures treated by anterior pelvic fixation with locking plates (14 patients, conventional locking plate fixation; 16 patients, pre-operative virtual simulation with 3D, printing-assisted, pre-contoured, locking plate fixation). We compared operative time, instrumentation time, blood loss, and post-surgical residual displacements, as evaluated on X-ray films, among groups. Statistical analyses evaluated significant differences between the groups for each of these variables. The patients treated with the virtual simulation and 3D printing-assisted technique had significantly shorter internal fixation times, shorter surgery duration, and less blood loss (- 57 minutes, - 70 minutes, and - 274 ml, respectively; P < 0.05) than patients in the conventional surgery group. However, the post-operative radiological result was similar between groups (P > 0.05). The complication rate was less in the 3D printing group (1/16 patients) than in the conventional surgery group (3/14 patients). The 3D simulation and printing technique is an effective and reliable method for treating anterior pelvic ring fractures. With precise pre-operative planning and accurate execution of the procedures, this time-saving approach can provide a more personalized treatment plan, allowing for a safer orthopaedic surgery.

  2. Percutaneous Intramedullary Screw Fixation of Distal Fibula Fractures: A Case Series and Systematic Review.

    PubMed

    Loukachov, Vladimir V; Birnie, Merel F N; Dingemans, Siem A; de Jong, Vincent M; Schepers, Tim

    The current reference standard for unstable ankle fractures is open reduction and internal fixation using a plate and lag screws. This approach requires extensive dissection and wound complications are not uncommon. The use of intramedullary screw fixation might overcome these issues. The aim of our study was to provide an overview of the published data regarding intramedullary screw fixation of fibula fractures combined with a small consecutive case series. We performed a search of published studies to identify the studies in which fibula fractures were treated with percutaneous intramedullary screw fixation. Additionally, all consecutive patients treated for an unstable ankle fracture in a level 1 trauma center using an intramedullary screw were retrospectively included. The literature search identified 6 studies with a total of 180 patients. Wound infection was seen in 1 patient (0.6%), anatomic reduction was achieved in 168 patients (93.3%), and a loss of reduction was seen in 2 patients (1.1%). Implant removal was deemed necessary in 3 patients (1.7%) and nonunion was seen is 2 patients (1.1%). A total of 11 patients, in whom no wound complications occurred, were included in our study. The follow-up duration was a minimum of 12 months. A secondary dislocation was seen in 1 patient, and delayed union was observed after 7.5 months in 1 other patient. In conclusion, intramedullary screw fixation is a safe and adequate method to use for fibula fractures, with a low risk of wound complications. Additional research regarding functional outcome is warranted. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. [Treatment of open tile type C pelvic fractures by open reduction and internal fixation through anterior and posterior approaches at early stage].

    PubMed

    Li, Baichuan

    2014-05-01

    To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.

  4. Technical considerations for surgical intervention of Jones fractures.

    PubMed

    Mendicino, Robert W; Hentges, Matthew J; Mendicino, Michael R; Catanzariti, Alan R

    2013-01-01

    Jones fractures are a common injury treated by foot and ankle surgeons. Surgical intervention is recommended because of the high rate of delayed union, nonunion, and repeat fracture, when treated conservatively. Percutaneous intramedullary screw fixation is commonly used in the treatment of these fractures. We present techniques that can increase the surgical efficiency and decrease the complications associated with percutaneous delivery of internal fixation. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Role of Ankle Arthroscopy in Management of Acute Ankle Fracture.

    PubMed

    Chan, Kwok Bill; Lui, Tun Hing

    2016-11-01

    To report the operative findings of ankle arthroscopy during open reduction and internal fixation of acute ankle fractures. This was a retrospective review of 254 consecutive patients with acute ankle fractures who were treated with open reduction and internal fixation of the fractures, and ankle arthroscopy was performed at the same time. The accuracy of fracture reduction, the presence of syndesmosis disruption and its reduction, and the presence of ligamentous injuries and osteochondral lesions were documented. Second-look ankle arthroscopy was performed during syndesmosis screw removal 6 weeks after the key operation. There were 6 patients with Weber A, 177 patients with Weber B, 51 patients with Weber C, and 20 patients with isolated medial malleolar fractures. Syndesmosis disruption was present in 0% of patients with Weber A fracture, 52% of patients with Weber B fracture, 92% of patients with Weber C fracture, and 20% of the patients with isolated medial malleolar fracture. Three patients with Weber B and one patient with Weber C fracture have occult syndesmosis instability after screw removal. Osteochondral lesion was present in no patient with Weber A fracture, 26% of the Weber B cases, 24% of the Weber C cases, and 20% of isolated medial malleolar fracture cases. The association between the presence of deep deltoid ligament tear and syndesmosis disruption (warranting syndesmosis screw fixation) in Weber B cases was statistically significant but not in Weber C cases. There was no statistically significant association between the presence of posterior malleolar fracture and syndesmosis instability that warrant screw fixation. Ankle arthroscopy is a useful adjuvant tool to understand the severity and complexity of acute ankle fracture. Direct arthroscopic visualization ensures detection and evaluation of intra-articular fractures, syndesmosis disruption, and associated osteochondral lesions and ligamentous injuries. Level IV, case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Rostral mandibular fracture repair in a pet bearded dragon (Pogona vitticeps).

    PubMed

    Nau, Melissa R; Eshar, David

    2018-04-15

    CASE DESCRIPTION A 2-year-old male bearded dragon (Pogona vitticeps) was evaluated because of a traumatic mandibular fracture. CLINICAL FINDINGS An open comminuted fracture of the rostral aspect of the right mandible was evident, with a fragment of bone exposed and dorsally displaced. Whole-body radiography revealed no evidence of additional injury. Other findings were unremarkable, except for moderate anemia (PCV, 19%). TREATMENT AND OUTCOME The fracture fragments were stabilized with 2 crossed 36-gauge interfragmentary wire loops. An external fixator device was fashioned from four 25-gauge needles inserted at alternating angles through the fracture fragments; plastic IV fluid line tubing filled with dental acrylic was used as a connecting bar. One day after surgery, the lizard had regained its typical activity level and appetite. Body weight was measured and the external fixator was inspected 1 week after surgery and monthly thereafter. Three months after initial injury, the fracture was stable, radiography revealed bony callus formation at the fracture site, and the external fixator was removed. Recheck radiography performed 5.5 months after initial injury revealed complete osseous union of the fracture fragments, and the interfragmentary wires were removed. CLINICAL RELEVANCE Surgical management of the traumatic comminuted mandibular fracture in this bearded dragon by means of a combination of internal and external fixation resulted in complete healing of the mandible and restoration of function. Management of this complicated fracture was achieved with the aid of readily available and inexpensive supplies in a clinical setting, which may be useful to other clinicians in the management of similar cases.

  7. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    PubMed

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  8. Surgical interventions for treating acute fractures or non-union of the middle third of the clavicle.

    PubMed

    Lenza, Mário; Faloppa, Flávio

    2015-05-07

    This review covers two conditions: acute clavicle fractures and non-union resulting from failed fracture healing. Clavicle (collarbone) fractures account for around 4% of all fractures. While treatment for these fractures is usually non-surgical, some types of clavicular fractures, as well as non-union of the middle third of the clavicle, are often treated surgically. This is an update of a Cochrane review first published in 2009. To evaluate the effects (benefits and harms) of different methods of surgical treatment for acute fracture or non-union of the middle third of the clavicle. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (27 June 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 5), MEDLINE (1966 to June week 3 2014), EMBASE (1988 to 2014 week 25), LILACS (1982 to 27 June 2014), trial registries and reference lists of articles. We applied no language or publication restrictions. We considered randomised and quasi-randomised controlled trials evaluating any surgical intervention for treating people with fractures or non-union of the middle third of the clavicle. The primary outcomes were shoulder function or disability, pain and treatment failure (measured by the number of participants who had undergone or were being considered for a non-routine secondary surgical intervention for symptomatic non-union, malunion or other complications). Two review authors selected eligible trials, independently assessed risk of bias and cross-checked data. Where appropriate, we pooled results of comparable trials. We included seven trials in this review with 398 participants. Four trials were new in this update.The four new trials (160 participants) compared intramedullary fixation with open reduction and internal fixation with plate for treating acute middle third clavicle fractures in adults. Low quality evidence from the four trials indicated that intramedullary fixation did not result in a clinically important improvement in upper arm function (despite a statistically significant difference in its favour: standardised mean difference 0.45, 95% confidence interval (CI) 0.08 to 0.81; 120 participants, three trials) at long term follow-up of six months or more. Very low quality evidence indicated little difference between intramedullary fixation and plate fixation in pain (one trial), treatment failure resulting in non-routine surgery (2/68 with intramedullary fixation vs. 3/65 with plate fixation; risk ratio 0.69, 95% CI 0.16 to 2.97, four trials) or time to clinical fracture consolidation (three trials). There was very low quality evidence of a lower incidence of participants with adverse events (mainly infection, poor cosmetic result and symptomatic hardware) in the intramedullary fixation group (18/68 with intramedullary fixation vs. 27/65 with plate fixation; RR 0.64, 95% CI 0.39 to 1.03) but the CI of the pooled results also included the small possibility of a lower incidence in the plate fixation group. None of the four trials reported on quality of life or return to previous activities. Evidence is pending from two ongoing trials, with planned recruitment of 245 participants, testing this comparison.There was low or very low quality evidence from three small trials, each testing a different comparison. The three trials had design features that carried a high risk of bias, potentially limiting the reliability of their findings. Low-contact dynamic compression plates appeared to be associated with significantly better upper-limb function throughout the year following surgery, earlier fracture union and return to work, and a reduced incidence of implant-associated symptoms when compared with a standard dynamic compression plate in 36 adults with symptomatic non-union of the middle third of the clavicle. One quasi-randomised trial (69 participants) compared Knowles pin versus a plate for treating middle third clavicle fractures or non-union. Knowles pins appeared to be associated with lower pain levels and use of postoperative analgesics and a reduced incidence of implant-associated symptoms. One study (133 participants) found that a three-dimensional technique for fixation with a reconstruction plate was associated with a significantly lower incidence of symptomatic delayed union than a standard superior position surgical approach. Evidence is pending from two ongoing trials, with planned recruitment of 130 participants, comparing anterior versus superior plates for acute fractures. There is very limited and low quality evidence available from randomised controlled trials regarding the effectiveness of different methods of surgical fixation of fractures and non-union of the middle third of the clavicle. The evidence from four ongoing trials is likely to inform practice for the comparisons of intramedullary versus plate fixation and anterior versus superior plates for acute fractures in a future update. Further randomised trials are warranted, but in order to optimise research effort, these should be preceded by research that aims to identify priority questions.

  9. Functional outcome after successful internal fixation versus salvage arthroplasty of patients with a femoral neck fracture.

    PubMed

    Zielinski, Stephanie M; Keijsers, Noël L; Praet, Stephan F E; Heetveld, Martin J; Bhandari, Mohit; Wilssens, Jean Pierre; Patka, Peter; Van Lieshout, Esther M M

    2014-12-01

    To determine patient independency, health-related and disease-specific quality of life (QOL), gait pattern, and muscle strength in patients after salvage arthroplasty for failed internal fixation of a femoral neck fracture. Secondary cohort study to a randomized controlled trial. Multicenter trial in the Netherlands, including 14 academic and nonacademic hospitals. Patients after salvage arthroplasty for failed internal fixation of a femoral neck fracture were studied. A comparison was made with patients who healed uneventfully after internal fixation. None (observatory study). Patient characteristics, SF-12, and Western Ontario McMaster osteoarthritis index scores were collected. Gait parameters were measured using plantar pressure measurement. Maximum isometric forces of the hip muscles were measured using a handheld dynamometer. Differences between the fractured and contralateral leg were calculated. Groups were compared using univariate analysis. Of 248 internal fixation patients (median age, 72 years), salvage arthroplasty was performed in 68 patients (27%). Salvage arthroplasty patients had a significantly lower Western Ontario McMaster osteoarthritis index score (median, 73 vs. 90; P = 0.016) than patients who healed uneventfully after internal fixation. Health-related QOL (SF-12) and patient independency did not differ significantly between the groups. Gait analysis showed a significantly impaired progression of the center of pressure in the salvage surgery patients (median ratio, -8.9 vs. 0.4, P = 0.013) and a significant greater loss of abduction strength (median, -25.4 vs. -20.4 N, P = 0.025). Despite a similar level of dependency and QOL, salvage arthroplasty patients have inferior functional outcome than patients who heal after internal fixation of a femoral neck fracture. Therapeutic level III.

  10. Trends in the volume of operative treatment of midshaft clavicle fractures in children and adolescents: a retrospective, 12-year, single-institution analysis.

    PubMed

    Suppan, Catherine A; Bae, Donald S; Donohue, Kyna S; Miller, Patricia E; Kocher, Mininder S; Heyworth, Benton E

    2016-07-01

    The purpose of this study was to examine institutional trends in the volume of clavicle fractures in children and adolescents. Medical records were retrospectively reviewed to identify patients aged 10-18 years treated for a clavicle fracture between 1999 and 2011 at a single tertiary-care pediatric hospital. There were significant increases in the number of clavicle fractures seen annually, of midshaft clavicle fractures, and of midshaft clavicle fractures treated operatively. The percentage of midshaft clavicle fractures treated with fixation also increased significantly. The volumes of clavicle fractures and midshaft clavicle fractures treated operatively appear to be increasing. Despite a lack of evidence-based support, the frequency of fixation of midshaft clavicle fractures appear to be increasing in the pediatric population.

  11. Mitochondrial Based Treatments that Prevent Posttraumatic Osteoarthritis in a Translational Large Animal Intraarticular Fracture Survival Model

    DTIC Science & Technology

    2012-09-01

    enhancing treatments in combination with antioxidants . Seven day biochemical assays demonstrated that proline...with semi- rigid fixation (middle); and after a 2.0 mm stepoff with rigid fixation. The fracture healed the reduced cases. Very little

  12. Treatment of stress fracture of the olecranon in throwing athletes with internal fixation through a small incision

    PubMed Central

    2012-01-01

    The present study is a report of retrospective case series of stress fracture of the olecranon. Six patients presented posterior elbow pain in throwing in baseball and softball, but fracture was not diagnosed in radiographs. We detected stress fracture of the olecranon using computed tomographic (CT) scan and treated the patient with internal fixation with a headless cannulated double threaded screw through a small skin incision. All patients returned to competitive level without elbow complaints after the operation. When throwing athletes present with unusual posterior elbow pain and no significant findings on radiographs, a CT scan examination should be performed. We recommend surgical treatment of internal fixation with a screw through a small skin incision, as a good option for stress fracture of the olecranon in order to allow early return to sports activity in competitive athletes. PMID:23241173

  13. Surgical treatment of intra-articular calcaneal fractures.

    PubMed

    Stapleton, John J; Zgonis, Thomas

    2014-10-01

    Most intra-articular calcaneal fractures are a result of high-energy trauma. The operative management of calcaneal fractures has been based on achieving anatomic reduction and minimizing complications of the compromised soft tissue envelope. The traditional extensile lateral approach offers advantages of achieving adequate fracture reduction with the risk of wound-healing complications and infection. Limited open reduction and internal fixation techniques with or without using external fixation focuses on achieving fracture reduction with less risk of wound complications but higher risk of malunion. This article discusses key points of operative management for various intra-articular calcaneal fracture patterns and clinical presentations. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Proximal femoral fractures: Principles of management and review of literature.

    PubMed

    Mittal, Ravi; Banerjee, Sumit

    2012-06-01

    The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems.

  15. Proximal femoral fractures: Principles of management and review of literature

    PubMed Central

    Mittal, Ravi; Banerjee, Sumit

    2012-01-01

    Purpose The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. Methods: A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Results and conclusions: Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems. PMID:25983451

  16. Results of operative fixation of unstable ankle fractures in geriatric patients.

    PubMed

    Pagliaro, A J; Michelson, J D; Mizel, M S

    2001-05-01

    It is widely accepted that operative fixation of unstable ankle fractures yields predictably good outcomes in the general population. The current literature, however reports less acceptable results in the geriatric population age 65 years and older. The current study analyzes the outcome of the surgical treatment of unstable ankle fractures in patients at least 65 years old. Twenty three patient over 65 years old were surgically treated after sustaining 21 (91%) closed and 2 (9%) open grade II unstable ankle fractures. Fractures were classified according to the Danis-Weber and Lauge-Hansen schemes. Fracture type was predominantly Weber B (21/23, 91%), or supination external rotation stage IV (21/23, 91%). Fracture union rate was 100%. There were three significant complications including a lateral wound dehiscence with delayed fibular union in an open fracture dislocation, and two below knee amputations, neither of which was directly related to the fracture treatment. There were three minor complications; one superficial wound infection and two cases of prolonged incision drainage, all of which resolved without further surgical intervention. Complications were associated with open fractures and preexisting systemic disease. These results indicate that open reduction and internal fixation of unstable ankle fractures in geriatric patients is an efficacious treatment regime that with results that are comparable to the general population.

  17. Design factors of femur fracture fixation plates made of shape memory alloy based on the Taguchi method by finite element analysis.

    PubMed

    Ko, Cheolwoong; Yang, Mikyung; Byun, Taemin; Lee, Sang-Wook

    2018-05-01

    This study proposed a way to design femur fracture fixation plates made of shape memory alloy based on computed tomography (CT) images of Korean cadaveric femurs. To this end, 3 major design factors of femur fracture fixation plates (circumference angle, thickness, and inner diameter) were selected based on the contact pressure when a femur fracture fixation plate was applied to a cylinder model using the Taguchi method. Then, the effects of the design factors were analyzed. It was shown that the design factors were statistically significant at a level of p = 0.05 concerning the inner diameter and the thickness. The factors affecting the contact pressure were inner diameter, thickness, and circumference angle, in that order. Particularly, in the condition of Case 9 (inner diameter 27 mm, thickness 2.4 mm, and circumference angle 270°), the max. average contact pressure was 21.721 MPa, while the min. average contact pressure was 3.118 MPa in Case 10 (inner diameter 29 mm, thickness 2.0 mm, and circumference angle 210°). When the femur fracture fixation plate was applied to the cylinder model, the displacement due to external sliding and pulling forces was analyzed. As a result, the displacement in the sliding condition was at max. 3.75 times greater than that in the pulling condition, which indicated that the cohesion strength between the femur fracture fixation plate and the cylinder model was likely to be greater in the pulling condition. When a human femur model was applied, the max. average contact pressure was 10.76 MPa, which was lower than the yield strength of a human femur (108 MPa). In addition, the analysis of the rib behaviors of the femur fracture fixation plate in relation to the recovery effect of the shape memory alloy showed that the rib behaviors varied depending on the arbitrarily curved shapes of the femur sections. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Role of Joshi's external stabilization system with percutaneous screw fixation in high-energy tibial condylar fractures associated with severe soft tissue injuries.

    PubMed

    Gupta, Ashish-Kumar; Sapra, Rahul; Kumar, Rakesh; Gupta, Som-Prakash; Kaushik, Devwart; Gaba, Sahil; Bansal, Mahesh Chand; Dayma, Ratan Lal

    2015-01-01

    The treatment of high-energy tibial condylar fractures which are associated with severe soft tissue injuries remains contentious and challenging. In this study, we assessed the results of Joshi's external stabilization system (JESS) by using the principle of ligamentotaxis and percutaneous screw fixation for managing high-energy tibial condylar fractures associated with severe soft tissue injuries. Between June 2008 and June 2010, 25 consecutive patients who were 17e71 years (mean, 39.7), underwent the JESS fixation for high-energy tibial condylar fractures associated with severe soft tissue injuries. Out of 25 patients, 2 were lost during follow-up and in 1 case early removal of frame was done, leaving 22 cases for final follow-up. Among them, 11 had poor skin condition with abrasions and blisters and 2 were open injuries (Gustilo-Anderson grade I&II). The injury mechanisms were motor vehicle accidents (n=19), fall from a height (n=2) and assault (n=1). The fractures were classified according to Schatzker classification system. There were 7 type-V, 14 type-VI and 1 type-lV Schatzker's tibial plateau fractures. The average interval between the injury and surgery was 6.8 days (range 2-13). The average hospital stay was 13 days (range, 7-22). The average interval between the surgery and full weight bearing was 13.6 weeks (range 11-20). The average range of knee flexion was 121°(range 105°-135°). The normal extension of the knee was observed in 20 patients, and an extensor lag of 5°-8° was noted in 2 patients. The complications included superficial pin tract infections (n=4) with no knee stiffness. JESS with lag screw fixation combines the benefit of traction, external fixation, and limited internal fixation, at the same time as allowing the ease of access to the soft tissue for wound checks, pin care, dressing changes, measurement of compartment pressure, and the monitoring of the neurovascular status. In a nutshell, JESS along with screw fixation offers a promising alternative treatment for high- energy tibial condylar fractures associated with severe soft tissue injuries.

  19. Complications of ankle fracture in patients with diabetes.

    PubMed

    Chaudhary, Saad B; Liporace, Frank A; Gandhi, Ankur; Donley, Brian G; Pinzur, Michael S; Lin, Sheldon S

    2008-03-01

    Ankle fractures in patients with diabetes mellitus have long been recognized as a challenge to practicing clinicians. Complications of impaired wound healing, infection, malunion, delayed union, nonunion, and Charcot arthropathy are prevalent in this patient population. Controversy exists as to whether diabetic ankle fractures are best treated noninvasively or by open reduction and internal fixation. Patients with diabetes are at significant risk for soft-tissue complications. In addition, diabetic ankle fractures heal, but significant delays in bone healing exist. Also, Charcot ankle arthropathy occurs more commonly in patients who were initially undiagnosed and had a delay in immobilization and in patients treated nonsurgically for displaced ankle fractures. Several techniques have been described to minimize complications associated with diabetic ankle fractures (eg, rigid external fixation, use of Kirschner wires or Steinmann pins to increase rigidity). Regardless of the specifics of treatment, adherence to the basic principles of preoperative planning, meticulous soft-tissue management, and attention to stable, rigid fixation with prolonged, protected immobilization are paramount in minimizing problems and yielding good functional outcomes.

  20. Regenerate bone fracture rate following femoral lengthening in paediatric patients

    PubMed Central

    Burke, N. G.; Cassar-Gheiti, A. J.; Tan, J.; McHugh, G.; O’Neil, B. J.; Noonan, M.; Moore, D.

    2017-01-01

    Abstract Purpose Femoral lengthening using a circular or mono-lateral frame is a commonly used technique. Fracture at the site of the regenerate bone is a major concern especially following removal of the external fixator. This aim of this study was to assess the rate of fracture of the regenerate bone in this single surgeon series of paediatric patients and determine potential risk factors. Methods Retrospective review of all the femoral lengthening performed by the senior author was performed. The medical and physiotherapy notes were reviewed. The gender, age at time of surgery, disease aetiology, total days in the external fixator and length of the new regenerate bone were recorded. Patients who sustained a regenerate fracture were identified. Results A total of 176 femoral lengthening procedures were performed on 108 patients. Eight regenerate fractures occurred in seven patients (4.5%). The mechanism of injury was a fall in five cases and during physiotherapy in three cases. The regenerate fracture occurred a median number of nine days following removal of frame. There was no significant difference between gender, age at time of surgery, total time in external fixator between those who sustained a regenerate fracture and those patients who did not. A significant difference was noted between the amount of lengthening between the ‘regenerate fracture group’ and the ‘no fracture group’ (50 mm vs 38 mm, respectively; p = 0.029). There was no association between disease aetiology and risk of regenerate fracture. Conclusions Femoral lengthening of more than 50 mm increases the risk of a fracture at the regenerate site regardless of the disease aetiology. We recommend avoidance of aggressive physiotherapy for the initial four weeks following external fixator removal. PMID:28828065

  1. A comparison of bicortical and intramedullary screw fixations of Jones' fractures.

    PubMed

    Husain, Zeeshan S; DeFronzo, Donna J

    2002-01-01

    Two different fixations for treatment of Jones' fracture were tested in bone models and cadaveric specimens to determine the differences in the stability of the constructs. A bicortical 3.5-mm cannulated cortical screw and an intramedullary 4.0-mm partially threaded cancellous screw were tested using physiologic loads with an Instron 8500 servohydraulic tensiometer (Instron Corporation, Canton, MA). In bone models, the bicortical construct (n = 5, 87+/-23 N) showed superior fixation strength (p = .0009) when compared to the intramedullary screw fixation (n = 5, 25+/-13 N). Cadaveric testing showed similar statistical significance (p = .0124) with the bicortical construct (n = 5, 152+/-71 N) having greater load resistance than the intramedullary screw fixation (n = 4, 29+/-20 N). In bone models, the bicortical constructs (23+/-9 N/mm) showed over twice the elastic modulus than the intramedullary screw fixations (9+/-4 N/mm) with statistical significance (p = .0115). The elastic modulus in the cadaveric group showed a similar pattern between the bicortical (19+/-17 N/mm) and intramedullary (9+/-6 N/mm) screw constructs. Analysis of the bicortical screw failure patterns revealed that screw orientation had a critical impact on fixation stability. The more distal the exit site of the bicortical screw was from the fracture site, the greater the load needed to displace the fixation.

  2. Functional outcome of Schatzker type V and VI tibial plateau fractures treated with dual plates

    PubMed Central

    Prasad, G Thiruvengita; Kumar, T Suresh; Kumar, R Krishna; Murthy, Ganapathy K; Sundaram, Nandkumar

    2013-01-01

    Background: Dual plate fixation in comminuted bicondylar tibial plateau fractures remains controversial. Open reduction and internal fixation, specifically through compromised soft tissues, has historically been associated with major wound complications. Alternate methods of treatment have been described, each with its own merits and demerits. We performed a retrospective study to evaluate the functional outcome of lateral and medial plate fixation of Schatzker type V and VI fractures through an anterolateral approach, and a medial minimally invasive approach or a posteromedial approach. Materials and Methods: We treated 46 tibial plateau fractures Schatzker type V and VI with lateral and medial plates through an anterolateral approach and a medial minimal invasive approach over an 8 years period. Six patients were lost to followup. Radiographs in two planes were taken in all cases. Immediate postoperative radiographs were assessed for quality of reduction and fixation. The functional outcome was evaluated according to the Oxford Knee Score criteria on followup. Results: Forty patients (33 men and 7 women) who completed the followup were included in the study. There were 20 Schatzker type V fractures and 20 Schatzker type VI fractures. The mean duration of followup was 4 years (range 1-8 years). All patients had a satisfactory articular reduction defined as ≤2 mm step-off or gap as assessed on followup. All patients had a good coronal and sagittal plane alignment, and articular width as assessed on supine X-rays of the knee in the anteroposterior (AP) and lateral views. The functional outcome, as assessed by the Oxford Knee Score, was excellent in 30 patients and good in 10 patients. All patients returned to their pre-injury level of activity and employment. There were no instances of deep infection. Conclusions: Dual plate fixation of severe bicondylar tibial plateau fractures is an excellent treatment option as it provides rigid fixation and allows early knee mobilization. Careful soft tissue handling and employing minimal invasive techniques minimizes soft tissue complications. PMID:23682182

  3. Comparison of clinical results between novel percutaneous pedicle screw and traditional open pedicle screw fixation for thoracolumbar fractures without neurological deficit.

    PubMed

    Yang, Ming; Zhao, Qinpeng; Hao, Dingjun; Chang, Zhen; Liu, Shichang; Yin, Xinhua

    2018-06-16

    To compare the efficacy and safety of novel percutaneous minimally invasive pedicle screw fixation and traditional open surgery for thoracolumbar fractures without neurological deficit. Sixty adult patients with single thoracolumbar fracture between June 2014 and June 2016 were recruited in this study, randomly divided into open fixation group (group A) or minimally invasive percutaneous fixation group (group B). Clinical and surgical evaluation including surgery time, blood losses, radiation times, hospital stay, and complication were performed. The two groups of patients with pre-operative and last follow-up anterior height ratio of fracture vertebral, Cobb angle of fracture vertebral, and VAS score of back pain were compared. All patients completed valid follow-ups, with an average time period of 15.4 months (12-26 months). Group B achieved much better results in time of operation, intra-operative blood loss, and length of stay than group A (P < 0.05). Group A was significantly better than group B in the times of radiation (P < 0.05). The VAS score was significantly lower in group B than in group A at three days after the operation (P < 0.05). There were no significant differences between the two groups in the anterior height ratio of fracture vertebral, Cobb angle, and VAS score in the last follow-up (P > 0.05). No injured nerve or other severe complications occurred in both groups; one of the patients from group A had back and loin pain lasting for about one month, which resolved after analgesia and functional training. There was no significant difference between the two groups in incidence of complications. Novel percutaneous pedicle screws with angle reset function can achieve the same effect as traditional open pedicle screw fixation in the treatment of thoracolumbar fractures without nerve injuries. Percutaneous minimally invasive pedicle screw fixation has the characteristics of shorter operative time, less bleeding, and less pain, but it needs more radiation times.

  4. Pelvic ring injuries: Surgical management and long-term outcomes

    PubMed Central

    Halawi, Mohamad J.

    2016-01-01

    Pelvic ring injuries present a therapeutic challenge to the orthopedic surgeon. Management is based on the patient's physiological status, fracture classification, and associated injuries. Surgical stabilization is indicated in unstable injury patterns and those that fail nonsurgical management. The optimal timing for definitive fixation is not clearly defined, but early stabilization is recommended. Surgical techniques include external fixation, open reduction and internal fixation, and minimally invasive percutaneous osteosynthesis. Special considerations are required for concomitant acetabular fractures, sacral fractures, and those occurring in skeletally immature patients. Long-term outcomes are limited by lack of pelvis-specific outcome measures and burden of associated injuries. PMID:26908968

  5. 7-year follow-up after open reduction and internal screw fixation in Bennett fractures.

    PubMed

    Leclère, Franck Marie Patrick; Jenzer, Achat; Hüsler, Rolf; Kiermeir, David; Bignion, Dietmar; Unglaub, Frank; Vögelin, Esther

    2012-07-01

    Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation. Between June 1997 and December 2005, 24 patients with Bennett fractures were treated with open reduction and internal fixation with screws at our center. Radiological and functional assessments including range of motion of the thumb and pinch and grip strength were performed 4 months post-procedure and at the long-term follow-up, on average 83 months after surgery. Reduction of the Bennett fracture was maintained as it was at the time of the procedure in 96 % of the cases when fixation with two lag screws was performed. At the 4-month follow-up, mean pinch and grip strength reached 92 ± 3 and 89 ± 4 % of the contralateral side, respectively. Long-term follow-up demonstrated no correlation between the accuracy of the fracture reduction and the development of post-traumatic arthritis. Good clinical results could be observed, if successful reduction of the fracture was achieved and maintained. However, there was no correlation between the accuracy of the fracture reduction considering a gap and step <2 mm and the development of arthritis.

  6. FAMI Screws for Mandibulo-Maxillary fixation in mandibular fracture treatment - Clinico-radiological evaluation.

    PubMed

    Kauke, Martin; Safi, Ali-Farid; Timmer, Marco; Nickenig, Hans-Joachim; Zöller, Joachim; Kreppel, Matthias

    2018-04-01

    Mandibulo-maxillary fixation (MMF) is indispensable for mandibular fracture treatment. Various means for MMF have been proposed, of which arch bars are widely considered to be the mainstay. However, disadvantages to this method have initiated a quest for an alternative, leading to the introduction of MMF screws. MMF screws have frequently been criticized for poor stability of fracture sites, root damage, hardware failure, and nerve damage. We retrospectively evaluate the FAMI (Fixation and Adaptation in Mandibular Injuries) screw in mandibular fracture treatment by scanning for clinically and radiologically visible complications. In total, 534 FAMI screws were used in the successful treatment of 96 males and 34 females. Condylar fractures were most commonly encountered, representing 120 of 241 fracture sites. 15 general fracture-related complications occurred, with the most common being nerve function impairment (3.8%) and postoperative malocclusion (4.6%). In nine cases (7%), clinically visible FAMI-screw-related complications occurred, with the most prevalent being screw loosening (2.3%) and mucosal signs of inflammation (3.1%). Duration of FAMI screws was associated with the occurrence of clinically visible complications (p = 0.042). Radiologically, clinically invisible dental hard tissue damage was noted in 21 individuals (16%). Therefore, FAMI screws seem to be a reliable and safe method for mandibulo-maxillary fixation. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. [Manipulative reduction and percutaneous Kirschner wire internal fixation for grade IV supination-external rotation ankle fractures].

    PubMed

    Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin

    2017-06-25

    To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.

  8. Modified tension band fixation and coracoclavicular stabilisation for unstable distal clavicle fracture.

    PubMed

    Choi, Sungwook; Kim, Sang-Rim; Kang, Hyunseong; Kim, Donghee; Park, Yong-Geun

    2015-02-01

    The purpose of this study was to report a new surgical technique for the treatment of unstable distal clavicle fracture with modified tension band fixation (MTBF) and coracoclavicular (CC) stabilisation, and evaluate the radiologic and clinical outcome of these patients. Thirteen patients who had a fracture of the distal clavicle (Neer classification type IIb) were treated with MTBF and CC stabilisation. After the CC stabilisation was performed with a suture anchor or flip button, internal fixation using MTBF was carried out. Each patient was followed up for a minimum of 12 months and their clinical and radiological results were analysed. The mean period required for fracture union was 12.6 (range, 8-24) weeks and union was successfully completed in all cases. The mean Constant score at the final follow-up was 94.7 (88-100); the modified University of California, Los Angeles (UCLA) shoulder rating scale was 31.3 points (range, 22-35). All patients returned to normal daily activities at an average of 3.7 months postoperatively (range, 3-5 months). One patient had a new fracture around drilled holes for CC stabilisation by inappropriate tunnelling. MTBF and CC stabilisation is a useful technique for treating an unstable distal clavicle fracture. This procedure provides minimal incision and stable fixation without causing any further acromioclavicular joint injury to those with distal clavicle fractures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures.

    PubMed

    Burnei, C; Popescu, Gh; Barbu, D; Capraru, F

    2011-11-14

    Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach.

  10. Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures

    PubMed Central

    Burnei, C; Popescu, Gh; Barbu, D; Capraru, F

    2011-01-01

    Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach. PMID:22514563

  11. Initial Experience of US Marine Corps Forward Resuscitative Surgical System during Operation Iraqi Freedom

    DTIC Science & Technology

    2005-01-01

    lavage, and splinting. Exter- nal fixation was used when there was concurrent vascular pro- cedures or if fractures were extremely unstable...foot open fracture Completion lower extremity amputation; completion right upper amputation; external fixation right ankle 8/Iraqi child Class 3 shock...infection Comminuted mandible fracture with loss of airway (casualty 1 in Table 2) Airway control Infection of mandibular plate at echelon 5 facility

  12. Hard tissue pediatric facial trauma: a review.

    PubMed

    Hogg, Nicholas J V; Horswell, Bruce B

    2006-01-01

    Although hard tissue injuries are uncommon in the pediatric patient, dentists may be involved in the initial assessment of these patients. In this paper, we review fractures of the facial skeleton with a focus on dentoalveolar injuries. Minimally displaced fractures in pediatric patients can be managed conservatively, while displaced fractures may require open approaches and rigid fixation. New fixation stratagems are presented, and possible facial growth disturbances resulting from trauma are discussed.

  13. Assessment of function-graded materials as fracture fixation bone-plates under combined loading conditions using finite element modelling.

    PubMed

    Fouad, H

    2011-05-01

    In previous work by Fouad (Medical Engineering and Physics 2010 [23]), 3D finite element (FE) models for fractured bones with function-graded (FG) bone-plates and traditional bone-plates made of stainless steel (SS) and titanium (Ti) alloy were examined under compressive loading conditions using the ABAQUS Code. In this study, the effects of the presence of the torsional load in addition to the compressive load on the predicted stresses of the fracture fixation bone-plate system are examined at different healing stages. The effects on the stress on the fracture site when using contacted and non-contacted bone-plate systems are also studied. The FE modelling results indicate that the torsional load has significant effects on the resultant stress on the fracture fixation bone-plate system, which should be taken into consideration during the design and the analysis. The results also show that the stress shielding at the fracture site decreases significantly when using FG bone-plates compared to Ti alloy or SS bone-plates. The presence of a gap between the bone and the plate results in a remarkable reduction in bone stress shielding at the fracture site. Therefore, the significant effects of using an FG bone-plate with a gap and the presence of torsional load on the resultant stress on the fracture fixation bone-plate system should be taken into consideration. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Titanium Mesh Shaping and Fixation for the Treatment of Comminuted Mandibular Fractures.

    PubMed

    Dai, Jiewen; Shen, Guofang; Yuan, Hao; Zhang, Wenbin; Shen, Shunyao; Shi, Jun

    2016-02-01

    Treating comminuted mandibular fractures remains a challenge. In this study, we used titanium mesh to treat comminuted mandibular fractures. Nine patients with traumatically comminuted mandibular fractures who received open reduction and internal stable fixation with titanium mesh were retrospectively reviewed. Open reduction-internal stable fixation was performed 7 to 10 days after primary debridement of the facial trauma. After the fractured mandible and the displaced fragments were reduced, the titanium mesh was reshaped according to the morphology of the mandible, and the reduced bone fragments were fixed with the reshaped titanium mesh and screws. Then, the surgical effects were evaluated during routine follow-up. Most of the displaced fragments were preserved and exhibited a favorable shaping ability in restoring the morphology of the mandible during surgery. No intraoperative complications were encountered. In addition, all patients were infection free, with no obvious resorption in the fixed fragments after surgery. The mandible also exhibited favorable morphology and offered sufficient bone mass for dental implantation or a denture prosthesis. We conclude that titanium mesh shaping and fixation can effectively treat comminuted mandibular fractures with little bone fragment loss, little soft tissue exposure, a low infection rate, and favorable mandibular morphology. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Self-reinforced bioresorbable poly-L/DL-lactide [SR-P(L/DL)LA] 70/30 miniplates and miniscrews are reliable for fixation of anterior mandibular fractures: a pilot study.

    PubMed

    Ylikontiola, Leena; Sundqvuist, Kai; Sàndor, George K B; Törmälä, Pertti; Ashammakhi, Nureddin

    2004-03-01

    Bioresorbable osteofixation devices are being increasingly used in orthognathic surgery and in cases of trauma to avoid problems associated with conventional metal osteofixation devices. The aim of this clinical study was to assess the reliability and efficacy of bioresorbable self-reinforced poly-L/DL-lactide (SR-P(L/DL)LA 70/30) plates and screws in the fixation of mandibular fractures in adults. Ten patients (20 to 49 years old) with isolated anterior mandibular parasymphyseal fractures were treated by means of open reduction and internal fixation using SR-P(L/DL)LA 70/30 bioresorbable plates and screws. During the minimum of 6 months of follow-up, no problems were encountered except for 1 case where a plate became exposed intraorally and infected. This required debridement and later excision of the exposed part of the plate. Despite this setback the fractured bone healed well. SR-P(L/DL)LA 70/30 plates and screws are reliable for internal fixation of anterior mandibular fractures in adults. Proper soft tissue coverage should be ensured to avoid plate exposure. Should implant exposure occur, it might be necessary to excise the exposed part after fracture healing (6-8 weeks postoperatively).

  16. Finite element analysis of a bone healing model: 1-year follow-up after internal fixation surgery for femoral fracture.

    PubMed

    Jiang-Jun, Zhou; Min, Zhao; Ya-Bo, Yan; Wei, Lei; Ren-Fa, Lv; Zhi-Yu, Zhu; Rong-Jian, Chen; Wei-Tao, Yu; Cheng-Fei, Du

    2014-03-01

    Finite element analysis was used to compare preoperative and postoperative stress distribution of a bone healing model of femur fracture, to identify whether broken ends of fractured bone would break or not after fixation dislodgement one year after intramedullary nailing. Method s: Using fast, personalized imaging, bone healing models of femur fracture were constructed based on data from multi-slice spiral computed tomography using Mimics, Geomagic Studio, and Abaqus software packages. The intramedullary pin was removed by Boolean operations before fixation was dislodged. Loads were applied on each model to simulate a person standing on one leg. The von Mises stress distribution, maximum stress, and its location was observed. Results : According to 10 kinds of display groups based on material assignment, the nodes of maximum and minimum von Mises stress were the same before and after dislodgement, and all nodes of maximum von Mises stress were outside the fracture line. The maximum von Mises stress node was situated at the bottom quarter of the femur. The von Mises stress distribution was identical before and after surgery. Conclusion : Fast, personalized model establishment can simulate fixation dislodgement before operation, and personalized finite element analysis was performed to successfully predict whether nail dislodgement would disrupt femur fracture or not.

  17. Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins.

    PubMed

    Christie, J; Howie, C R; Armour, P C

    1988-03-01

    One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.

  18. [Clinical practice guideline on closed tibial plateau fractures in adulthood].

    PubMed

    Ocegueda-Sosa, Miguel Ángel; Valenzuela-Flores, Adriana Abigail; Aldaco-García, Víctor Daniel; Flores-Aguilar, Sergio; Manilla-Lezama, Nicolás; Pérez-Hernández, Jorge

    2013-01-01

    Closed tibiae plateau fractures are common injuries in the emergency room. The optimal treatment is not well defined or established. For this reason, there are several surgical management options: open reduction and internal fixation, closed reduction and percutaneous synthesis, external fixation, and even conservative treatment for this kind of fracture. The mechanism of production of this fracture is through large varus or valgus deformation to which is added a factor of axial load. The trauma may be direct or indirect. The degree of displacement, fragmentation and involvement of soft tissues like ligaments, menisci, vascular and nerve structures are determined by the magnitude of the force exerted. Any intra-articular fracture treatment can lead to an erroneous instability, deformity and limitation of motion with subsequent arthritic changes, leading to joint incongruity, limiting activity and significantly altering the quality of life. Open reduction and internal fixation with anatomic restitution is the method used in this type of fracture. However, the results of numerous publications can be questioned due to the inclusion in the same study of fractures treated with very different methods.

  19. Fixation of osteoporotic fractures in the upper limb with a locking compression plate.

    PubMed

    Neuhaus, V; King, J D; Jupiter, J B

    2012-01-01

    Locking Compression Plate (LCP) has the advantageous feature that screws can be locked in the plate leaving an angular stable construct. There is no need to have contact between the plate and the bone to achieve stability resulting from friction of the plate-bone-construct. Therefore the plate does not need to be contoured exactly to the bone and the healing bone's periosteal blood supply is not affected. The LCP is used as a bridging plate to gain relative stability in multi-fragmentary, diaphyseal or metaphyseal fractures. Depending on the fracture, the combination hole can also allow the LCP to achieve absolute stability similar to conventional fixation techniques. Osteoporotic fractures have significant impact on morbidity and mortality. Proximal humeral and distal radius fractures are typical examples. These osteoporotic and often comminuted fractures are ideal settings/indications for LCP utilization in the upper extremity. However, the data quality is due to mostly small study populations not so powerful. Unquestionably there has been a clear and fashionable trend to choose operative treatment for these fractures, because the angular stability allows stable fixation and early functional mobilization.

  20. Stabilization of Volar Ulnar Rim Fractures of the Distal Radius: Current Techniques and Review of the Literature

    PubMed Central

    O'Shaughnessy, Maureen A.; Shin, Alexander Y.; Kakar, Sanjeev

    2016-01-01

    Background Distal radius fractures involving the lunate facet can be challenging to manage. Reports have shown the volar carpal subluxation/dislocation that can occur if the facet is not appropriately stabilized. Literature Review Recent emphasis in the literature has underscored the difficulty in managing this fracture fragment, suggesting standard volar plates may not be able to adequately stabilize the fragment. This article reviews the current literature with a special emphasis on fixation with a specifically designed fragment-specific hook plate to secure the lunate facet. Case Description An extended flexor carpi radialis volar approach was made which allows access to the distal volar ulnar fracture fragment. Once provisionally stabilized with Kirschner wire fixation, a volar hook plate was applied to capture this fragment. Additional fracture stabilization was used as deemed necessary to stabilize the remaining distal radius fracture. Clinical Relevance The volar marginal rim fragment remains a challenge in distal radius fracture management. Use of a hook plate to address the volar ulnar corner allows for stable fixation without loss of reduction at intermediate-term follow-up. PMID:27104076

  1. The Metacarpal Locked Intramedullary Nail: Comparative Biomechanical Evaluation of New Implant Design for Metacarpal Fractures.

    PubMed

    Boonyasirikool, Chinnakart; Tanakeatsakul, Sakkarin; Niempoog, Sunyarn

    2015-04-01

    The optimal fixation of metacarpal fracture should provide sufficient stability to permit early functionfor all types of fracture. However; it must preserve surrounding soft tissue during application and not require secondary removal due to its prominence. The prototype of metacarpal locked intramedullary nail (MCLN) was designed by our institute aiming to achieve those allfeatures. To biomechanically test our newly designed, locked metacarpal nail and compare with common current available fixation methods. Thirty chicken humeri were devided into 3 groups (n = 1 per group) according tofixation techniques: MCLN, 1.5 mm miniplate (Synthes), and Kirschner wire. After complete fixation, all specimens were osteotomized at mid-shaft creating transverse fractures. Five specimens from each group were tested by load of failure under axial compression, and another five under bending force. In axial compression model, the loads tofailure in MCLN group was greatest (460 ± 17 N), which was significant higher than the Kirschner wire group. The MCLN group also showed the highest load to failure in bending test (341 ± 10 N). This value reaches statistical significance when compared with plate and Kirschner wire groups. The MCLN construct provided higher stability than miniplate and Kirschner wire fixation both in axial and bending mode. Together with the minimally invasive and soft tissue-friendly design concept, this study suggests that MCLN is promising fixation option for metacarpal fracture.

  2. Temporary Stabilization with External Fixator in ‘Tripolar’ Configuration in Two Steps Treatment of Tibial Pilon Fractures

    PubMed Central

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    Background: The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. Methods: We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. Results: We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation Conclusion: Temporary stabilization with external fixator in ‘tripolar’ configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases. PMID:27123151

  3. Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures.

    PubMed

    Wang, Cheng; Li, Ying; Huang, Lei; Wang, Manyi

    2010-10-01

    To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I and II. Two-staged ORIF was performed in group I and LIFEF in group II. The outcome measures included bone union, nonunion, malunion, pin-tract infection, wound infection, osteomyelitis, ankle joint function, etc. These postoperative data were analyzed with Statistical Package for Social Sciences (SPSS) 13.0. Incidence of superficial soft tissue infection (involved in wound infection or pin-tract infection) in group I was lower than that in group II (P < 0.05), with significant difference. Group I has significantly less radiation exposure (P < 0.001). Group II had higher rates of malunion, delayed union, and arthritis symptoms, with no statistical significance. Both groups resulted similar ankle joint function. Logistic regression analysis indicated that smoking and fracture pattern were the two factors significantly influencing the final outcomes. In the treatment of closed tibial plafond fractures, both two-staged ORIF and LIFEF offer similar results. Patients undergo LIFEF carry significantly greater radiation exposure and higher superficial soft tissue infection rate (usually occurs on pin tract and does not affect the final outcomes).

  4. Prevalence of Jones Fracture Repair and Impact on Short-Term NFL Participation.

    PubMed

    Tu, Leigh-Anne; Knapik, Derrick M; Sheehan, Joseph; Salata, Michael J; Voos, James E

    2018-01-01

    Elite American football athletes are at high risk for Jones fractures. Fixation is recommended to minimize nonunion and allow early return to play. The purpose of this investigation was to evaluate the prevalence of Jones fracture repair in athletes invited to the National Football League (NFL) Combine and the impact of fracture repair on short-term NFL participation compared to athletes with no history of repair. A total of 1311 athletes participating in the Combine from 2012 to 2015 were evaluated. Athletes with history of Jones fracture repair were identified. Athlete demographic information was collected while physical examination findings were recorded. Radiographs were evaluated to determine fixation type and the presence of nonunion. Future participation in the NFL was evaluated based on draft status, games played, and games started in the athlete's first season following the Combine. Fixation was performed for 41 Jones fractures in 40 athletes (3.1%). The highest prevalence was in defensive linemen (n = 10 athletes), with the greatest rate in tight ends (5.1%, n = 4 of 79 athletes). Intramedullary screw fixation was used for all fractures. Incomplete bony union was present in 3 (8%) fractures. Athletes with a history of repair were not at significant risk for going undrafted ( P = .61), playing ( P = .23), or starting ( P = .76) fewer NFL games compared to athletes with no history of repair during athletes' first NFL season. Athletes with a history of Jones fracture repair were not at significant risk of going undrafted or for diminished participation during their first season in the NFL. Level IV, case series.

  5. Open unstable metaphyseo-diaphyseal fractures of the tibia in adolescents: treatment by flexible intramedullary nails augmented by external fixator.

    PubMed

    Atef, Ashraf; El Tantawy, Ahmad

    2015-05-01

    The treatment of open and unstable metaphyseo-diaphyseal fractures of the tibia in adolescents is challenging. It is important to choose a fixation method that can maintain alignment, allow wound care and not violate the growth plate. The aim of this work was to evaluate the efficacy of using flexible intramedullary nails (FIN) augmented by external fixator (EF) in the management of such fractures. A total of 26 males, with a mean age of 14.08 years and average body weight of 49.8 kg, presented with open metaphyseo-diaphyseal tibial fractures. All cases were treated using FIN augmented by mono-lateral EF. The fractures were located at the upper third in 17 cases and at the lower third in nine cases. The fracture pattern was spiral in eight cases, oblique in seven and multi-fragmentary in 11. The results were evaluated according to the scoring system for femoral TENs. All fractures united primarily after an average eight to 12 weeks with no evident angular deformity or limb-length discrepancy. None of the cases required cast immobilization or revision procedure. Twenty patients had excellent results, six patients showed good results and none had poor results. Fracture characteristics as well as patients' characteristics had no statistically significant effect (p > 0.005) on the final end results. The use of FIN augmented by EF is a good alternative in the management of open metaphyseo-diaphyseal tibial fractures in adolescents. This fixation provides more stability, allows easy access to the wound and early patients' ambulation.

  6. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135º single-angled barrel plate for un-united and neglected femoral neck fractures.

    PubMed

    Gupta, Sameer; Kukreja, Sunil; Singh, Vivek

    2014-04-01

    To review the outcome of 60 patients who underwent valgus subtrochanteric osteotomy and its repositioning for un-united and neglected femoral neck fractures. 60 patients (mean age, 35 years) underwent valgus subtrochanteric osteotomy and repositioning of the osteotomy and fixation with a dynamic hip screw and a 135° single-angled barrel plate for closed un-united femoral neck fractures after failed internal fixation (n=27) or neglected (>3 weeks) fractures (n=33). The most common fracture type was transcervical (n=48), followed by subcapital (n=6) and basal (n=6). All patients had displaced femoral neck fractures (Garden types 3 and 4). According to the Pauwel angle, 45 fractures were type 2 (30º-70º) and 15 were type 3 (>70º). Patients were followed up for a mean of 3.5 (range, 2-7.5) years. The mean Pauwel angle of the fracture was corrected from 65° (range, 50°-89°) to 26° (range, 25°-28°). Bone union was achieved in 56 patients after a mean of 3.9 (range, 3-5.5) months. The mean Harris hip score improved from 65 to 87.5. Outcome was excellent in 30 patients, good in 24, and poor in 6. Four of the patients developed avascular necrosis; 2 of whom nonetheless achieved a good outcome. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135° single-angled barrel plate was effective treatment for un-united and neglected femoral neck fractures.

  7. Implant Removal after Percutaneous Short Segment Fixation for Thoracolumbar Burst Fracture : Does It Preserve Motion?

    PubMed Central

    Kim, Hyeun Sung; Ju, Chang Il; Wang, Hui Sun; Lee, Sung Myung; Kim, Dong Min

    2014-01-01

    Objective The purpose of this study was to evaluate the efficacy of implant removal of percutaneous short segment fixation after vertebral fracture consolidation in terms of motion preservation. Methods Between May 2007 and January 2011, 44 patients underwent percutaneous short segment screw fixation due to a thoracolumbar burst fracture. Sixteen of these patients, who underwent implant removal 12 months after screw fixation, were enrolled in this study. Motor power was intact in all patients, despite significant vertebral height loss and canal compromise. The patients were divided into two groups by degree of osteoporosis : Group A (n=8), the non-osteoporotic group, and Group B (n=8), the osteoporotic group. Imaging and clinical findings including vertebral height loss, kyphotic angle, range of motion (ROM), and complications were analyzed. Results Significant pain relief was achieved in both groups at final follow-up versus preoperative values. In terms of vertebral height loss, both groups showed significant improvement at 12 months after screw fixation and restored vertebral height was maintained to final follow-up in spite of some correction loss. ROM (measured using Cobb's method) in flexion and extension in Group A was 10.5° (19.5/9.0°) at last follow-up, and in Group B was 10.2° (18.8/8.6°) at last follow-up. Both groups showed marked improvement in ROM as compared with the screw fixation state, which was considered motionless. Conclusion Removal of percutaneous implants after vertebral fracture consolidation can be an effective treatment to preserve motion regardless of osteoporosis for thoracolumbar burst fractures. PMID:24653799

  8. Internal Fixation of Complicated Acetabular Fractures Directed by Preoperative Surgery with 3D Printing Models.

    PubMed

    Liu, Zhao-Jie; Jia, Jian; Zhang, Yin-Guang; Tian, Wei; Jin, Xin; Hu, Yong-Cheng

    2017-05-01

    The purpose of this article is to evaluate the efficacy and feasibility of preoperative surgery with 3D printing-assisted internal fixation of complicated acetabular fractures. A retrospective case review was performed for the above surgical procedure. A 23-year-old man was confirmed by radiological examination to have fractures of multiple ribs, with hemopneumothorax and communicated fractures of the left acetabulum. According to the Letounel and Judet classification, T-shaped fracture involving posterior wall was diagnosed. A 3D printing pelvic model was established using CT digital imaging and communications in medicine (DICOM) data preoperatively, with which surgical procedures were simulated in preoperative surgery to confirm the sequence of the reduction and fixation as well as the position and length of the implants. Open reduction with internal fixation (ORIF) of the acetabular fracture using modified ilioinguinal and Kocher-Langenbeck approaches was performed 25 days after injury. Plates that had been pre-bent in the preoperative surgery were positioned and screws were tightened in the directions determined in the preoperative planning following satisfactory reduction. The duration of the operation was 170 min and blood loss was 900 mL. Postoperative X-rays showed that anatomical reduction of the acetabulum was achieved and the hip joint was congruous. The position and length of the implants were not different when compared with those in preoperative surgery on 3D printing models. We believe that preoperative surgery using 3D printing models is beneficial for confirming the reduction and fixation sequence, determining the reduction quality, shortening the operative time, minimizing preoperative difficulties, and predicting the prognosis for complicated fractures of acetabulam. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  9. Comparing fracture healing disorders and long-term functional outcome of polytrauma patients and patients with an isolated displaced midshaft clavicle fracture.

    PubMed

    Ferree, Steven; Hietbrink, Falco; van der Meijden, Olivier A J; Verleisdonk, Egbert Jan M M; Leenen, Luke P H; Houwert, Roderick M

    2017-01-01

    Although clavicle fractures are a common injury in polytrauma patients, the functional outcome of displaced midshaft clavicle fractures (DMCFs) in this population is unknown. Our hypothesis was that there would be no differences in fracture healing disorders or functional outcome in polytrauma patients with a DMCF compared with patients with an isolated DMCF, regardless of the treatment modality. A retrospective cohort study of patients (treated at our level I trauma center) with a DMCF was performed and a follow-up questionnaire was administered. Polytrauma patients, defined as an Injury Severity Score ≥16, and those with an isolated clavicle fracture were compared. Fracture healing disorders (nonunion and delayed union) and delayed fixation rates were determined. Functional outcome was assessed by the Quick Disability of the Arm, Shoulder, and Hand questionnaire. A total of 152 patients were analyzed, 71 polytrauma patients and 81 patients with an isolated DMCF. Questionnaire response of 121 patients (80%) was available (mean, 53 months; standard deviation, 22 months). No differences were found between polytrauma patients and those with an isolated DMCF with regard to nonunion (7% vs. 5%, respectively), delayed union (4% vs. 4%), and delayed fixation rate (13% vs. 13%). Polytrauma patients had an overall worse functional outcome, regardless of initial nonoperative treatment or delayed operative fixation. Polytrauma patients had a similar nonunion and delayed fixation rate but had an overall worse functional outcome compared with patients with an isolated DMCF. For polytrauma patients, a wait and see approach can be advocated without the risk of decreased upper extremity function after delayed fixation. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Mid-term functional outcome after the internal fixation of distal radius fractures

    PubMed Central

    2012-01-01

    Background Distal radius fracture is a common injury with a variety of operative and non-operative management options. There remains debate as to the optimal treatment for a given patient and fracture. Despite the popularity of volar locking plate fixation, there are few large cohort or long term follow up studies to justify this modality. Our aim was to report the functional outcome of a large number of patients at a significant follow up time after fixation of their distal radius with a volar locking plate. Methods 180 patients with 183 fractures and a mean age of 62.4 years were followed up retrospectively at a mean of 30 months (Standard deviation = 10.4). Functional assessment was performed using the Disabilities of the Arm, Shoulder and Hand (DASH) and modified MAYO wrist scores. Statistical analysis was performed to identify possible variables affecting outcome and radiographs were assessed to determine time to fracture union. Results The median DASH score was 2.3 and median MAYO score was 90 for the whole group. Overall, 133 patients (74%) had a good or excellent DASH and MAYO score. Statistical analysis showed that no specific variable including gender, age, fracture type, post-operative immobilisation or surgeon grade significantly affected outcome. Complications occurred in 27 patients (15%) and in 11 patients were major (6%). Conclusion This single centre large population series demonstrates good to excellent results in the majority of patients after volar locking plate fixation of the distal radius, with complication rates comparable to other non-operative and operative treatment modalities. On this basis we recommend this mode of fixation for distal radius fractures requiting operative intervention. PMID:22280557

  11. Mid-term functional outcome after the internal fixation of distal radius fractures.

    PubMed

    Phadnis, Joideep; Trompeter, Alex; Gallagher, Kieran; Bradshaw, Lucy; Elliott, David S; Newman, Kevin J

    2012-01-26

    Distal radius fracture is a common injury with a variety of operative and non-operative management options. There remains debate as to the optimal treatment for a given patient and fracture. Despite the popularity of volar locking plate fixation, there are few large cohort or long term follow up studies to justify this modality. Our aim was to report the functional outcome of a large number of patients at a significant follow up time after fixation of their distal radius with a volar locking plate. 180 patients with 183 fractures and a mean age of 62.4 years were followed up retrospectively at a mean of 30 months (Standard deviation=10.4). Functional assessment was performed using the Disabilities of the Arm, Shoulder and Hand (DASH) and modified MAYO wrist scores. Statistical analysis was performed to identify possible variables affecting outcome and radiographs were assessed to determine time to fracture union. The median DASH score was 2.3 and median MAYO score was 90 for the whole group. Overall, 133 patients (74%) had a good or excellent DASH and MAYO score. Statistical analysis showed that no specific variable including gender, age, fracture type, post-operative immobilisation or surgeon grade significantly affected outcome. Complications occurred in 27 patients (15%) and in 11 patients were major (6%). This single centre large population series demonstrates good to excellent results in the majority of patients after volar locking plate fixation of the distal radius, with complication rates comparable to other non-operative and operative treatment modalities. On this basis we recommend this mode of fixation for distal radius fractures requiting operative intervention.

  12. [Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures].

    PubMed

    Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun

    2017-07-01

    To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P <0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B ( P <0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference ( χ 2 =0.055, P =0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups ( χ 2 =0.056, P =0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups ( t =-0.028, P =0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P <0.05). The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

  13. Arthroplasty for Unreconstructable Acute Fractures and Failed Fracture Fixation About the Hip and Knee in the Active Elderly: A New Paradigm.

    PubMed

    Kyle, Richard F; Duwelius, Paul J; Haidukewych, George J; Schmidt, Andrew H

    2017-02-15

    The techniques, materials, and designs for total joint arthroplasty underwent major improvements in the past 30 years. During this time, trauma surgeons classified the severity of fractures as well as identified certain articular fractures that do not have good outcomes and have a high rate of failure after internal fixation. Advanced improvements in arthroplasty have increased its reliability and longevity. Total joint arthroplasty is becoming a standard of care for some acute articular fractures, particularly displaced femoral neck fractures in the active elderly. Total joint arthroplasty also has become the standard of care after failed internal fixation in patients who have very complicated fractures about the knee, hip, and shoulder. As the population ages, fractures worldwide continue to rapidly increase. Elderly patients have a high risk for fractures that result from falls because of their poor bone quality. The current active elderly population participates in higher risk activities than previous elderly populations, which places them at risk for more injuries. This has become both a worldwide healthcare problem and an economic problem. Surgeons need to manage fractures in the active elderly with the latest advancements in technology and patient selection to ensure rapid recovery and the reduction of complications.

  14. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  15. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  16. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  17. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  18. 21 CFR 878.3250 - External facial fracture fixation appliance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External facial fracture fixation appliance. 878.3250 Section 878.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3250...

  19. Management of distal humeral coronal shear fractures

    PubMed Central

    Yari, Shahram S; Bowers, Nathan L; Craig, Miguel A; Reichel, Lee M

    2015-01-01

    Coronal shear fractures of the distal humerus are rare, complex fractures that can be technically challenging to manage. They usually result from a low-energy fall and direct compression of the distal humerus by the radial head in a hyper-extended or semi-flexed elbow or from spontaneous reduction of a posterolateral subluxation or dislocation. Due to the small number of soft tissue attachments at this site, almost all of these fractures are displaced. The incidence of distal humeral coronal shear fractures is higher among women because of the higher rate of osteoporosis in women and the difference in carrying angle between men and women. Distal humeral coronal shear fractures may occur in isolation, may be part of a complex elbow injury, or may be associated with injuries proximal or distal to the elbow. An associated lateral collateral ligament injury is seen in up to 40% and an associated radial head fracture is seen in up to 30% of these fractures. Given the complex nature of distal humeral coronal shear fractures, there is preference for operative management. Operative fixation leads to stable anatomic reduction, restores articular congruity, and allows initiation of early range-of-motion movements in the majority of cases. Several surgical exposure and fixation techniques are available to reconstruct the articular surface following distal humeral coronal shear fractures. The lateral extensile approach and fixation with countersunk headless compression screws placed in an anterior-to-posterior fashion are commonly used. We have found a two-incision approach (direct anterior and lateral) that results in less soft tissue dissection and better outcomes than the lateral extensile approach in our experience. Stiffness, pain, articular incongruity, arthritis, and ulnohumeral instability may result if reduction is non-anatomic or if fixation fails. PMID:25984515

  20. Comparative study of comminuted posterior acetabular wall fracture treated with the Acetabular Tridimensional Memory Fixation System.

    PubMed

    Zhang, Yuntong; Zhao, Xue; Tang, Yang; Zhang, Chuncai; Xu, Shuogui; Xie, Yang

    2014-04-01

    Posterior wall fractures are one of the most common acetabular fractures. However, only 30% of these fractures involve a single large fragment, and comminuted acetabular posterior wall fractures pose a particular surgical challenge. The purpose of this study was to compare outcomes between patients who received fixation for comminuted posterior wall fracture using the Acetabular Tridimensional Memory Fixation System (ATMFS) and patients who underwent fixation with conventional screws and buttress plates (Plates group). Between April 2003 and May 2007, 196 consecutive patients who sustained a comminuted posterior wall fracture of acetabulum were treated with ATMFS or conventional screws and buttress plates. Operative time, fluoroscopy time, blood loss, and any intra-operative complications were recorded. Plain AP and lateral radiographs were obtained at all visits (Matta's criteria). Modified Merle d' Aubigne-Postel score, and Mos SF-36 score were compared between groups. Fifty patients were included in the analysis with 26 in the ATMFS group and 24 in the Plates group. The mean follow-up time was 57.5 months, ranging from 31 to 69 months. All patients had fully healed fractures at the final follow-up. There was no difference in clinical outcomes or radiological evaluations between groups. Patients with comminuted posterior wall fractures of the acetabulum treated with the ATMFS or conventional screws and buttress plate techniques achieve a good surgical result. Both techniques are safe, reliable, and practical. Use of the ATMFS technique may reduce blood loss and improve rigid support to marginal bone impaction. The use ATMFS may need additional support when fractures involve the superior roof. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Use of the TRPV1 Agonist Capsaicin to Provide Long-Term Analgesia in a Rat Limb Fracture/Open Repair, Internal Fixation Model

    DTIC Science & Technology

    2012-10-01

    W81XWH-10-2-0093 TITLE: Use of the TRPV1 Agonist Capsaicin to Provide Long-Term Analgesia in a Rat Limb Fracture/Open Repair, Internal Fixation Model...2. REPORT TYPE Final 3. DATES COVERED (From - To) 30September2010-29September2012 4. TITLE AND SUBTITLE Use of the TRPV1 Agonist Capsaicin to...capsaicin around the fracture site. 15. SUBJECT TERMS Femur fracture, Rat Model, Pain, Capsaicin, Trauma, TRPV1 16. SECURITY CLASSIFICATION OF

  2. [Analysis of reason and strategy for the failure of posterior pedicle screw short-segment internal fixation on thoracolumbar fractures].

    PubMed

    Xing, Jin-Ming; Peng, Wen-Ming; Shi, Chu-Yun; Xu, Lei; Pan, Qi-Huao

    2013-03-01

    To analyze the reason and strategy for failure of posterior pedicle screw short-segment internal fixation on thoracolumbar fractures. From March 2008 to December 2010,the clinical data of 18 patients with thoracolumbar fracture failed in posterior pedicle screw short-segment internal fixation were retrospectively analyzed. There were 11 males and 7 females with an average age of 37.2 years (ranged, 19 to 63). The time from the first operation to complication occurrence was from 6 to 44 months with an average of 14.3 months. Of them,fusion failure was in 7 cases (combined with screw breakage in 4 cases), the progressive neuro-dysfunction was in 5 cases,the progressive lumbodorsal pain was in 6 cases. All 18 patients with kyphosis were treated with anterior internal fixation remaining posterior fixation (9 cases) and anterior internal fixation after posterior fixation removal (9 cases). All the patients were followed up from 18 to 50 months with an average of 30.5 months. No intetnal fixation loosening and breakage were found, moreover, X-ray and lamellar CT showed bone healing well. Preoperative, postoperative at 3 months and at final follow-up, ODI score was respectively 31.6+/-5.1, 8.6+/-5.7, 8.3+/-3.2; VAS score was respectively 7.2+/-2.3, 2.3+/-0.7, 2.1+/-1.1; kyphosis angle was respectively (-21.2/-+7.8 degreeso, (-5.3+/-6.8 degrees ), (-5.8+/-7.8 )degrees. Compared with preoperative data ,above-listed items had obviously ameliorated(P<0.05). Treatment of thoracolumbar fracture with posterior pedicle screw short-segment internal fixation may result in the complications such as bone nonunion ,internal fixation breakage and progressive kyphosis. Anterior reconstruction may be a good strategy for the failure of posterior operation.

  3. Comparative analysis of fracture characteristics of the developing mandible: the Mayo Clinic experience.

    PubMed

    Siwani, Rizwan; Tombers, Nicole M; Rieck, Kevin L; Cofer, Shelagh A

    2014-07-01

    To review and compare the epidemiology and treatment of mandibular fractures in subgroups of a pediatric population. We conducted a retrospective review of pediatric patients (age, ≤18 years) with mandibular fractures treated at our institution from January 1996 through November 2011. We identified 122 patients (93 [76%] male) with 216 mandibular fractures. The prevalent mechanisms of injury were motor vehicle accidents (n=52 [43%]), sports injuries (n=24 [20%]), and assault (n=13 [11%]). The most common fracture sites were subcondylar, parasymphyseal, angle, and body. Two patients (2%) were treated conservatively by observation only, 67 (55%) underwent maxillomandibular fixation alone, 41 (34%) underwent maxillomandibular fixation with plate fixation, and 7 (5.7%) underwent plate fixation only. The average duration of maxillomandibular fixation was 26 days (range, 7-49 days). Complications occurred in 11 patients (9.0%) over a mean follow-up of 92 days (range, 21-702 days). Fifty patients (41.0%) had comorbid conditions or a history of mental illness at the time of injury, including attention deficit hyperactivity disorder (n=11 [9%]), mental disorders other than attention deficit hyperactivity disorder (n=23 [19%]), and asthma (n=17 [14%]). Twenty-six patients (21%) had a history of substance use, the most common being tobacco (n=18 [15%]), alcohol (n=13 [11%]), and marijuana (n=11 [9%]). Treatment approach and outcomes were affected by age and fracture characteristics. In addition, a marked proportion of this cohort had preexisting mental disorders and history of substance use, which may have implications on treatment approach. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. [Effective analysis of percutaneous reduction and Kirschner pin fixation for the treatment of intraarticular fractures of the calcaneus in children].

    PubMed

    Huang, Zhong-sheng; Zhao, Zhen; Ji, Ying-yao; Li, Ke-lun; Zheng, Ju-han; Ni, Jian-guang; Xu, Can-zhen; Zheng, Li-cheng

    2011-10-01

    To introduce and evaluate the clinical effects of percutaneous reduction and Kirschner pin fixation for the treatment of intraarticular fractures of the calcaneus in children. From March 2001 to February 2009,12 patients with intraarticular calcaneal fractures were treated by percutaneous reduction and Kirschner pin fixation (13 feet). There were 8 males and 4 females,ranging in age from 3 to 14,with an average of 8.7 years. According to Essex-Lopresti classification, among 5 feet were tongue fractures and 8 feet were compressed fractures. According to Sanders classification, 9 feet were type II and 4 feet were type III. The Biihler angle and Gissane angle of the calcaneus were obtained before and after operation. All patients were evaluated according to Maryland Foot Score. All the patients were followed up for 16-71 months (means 35.9 months),and all the incisions were healed without complications and infection. The preoperative X-ray film showed that Böhler angle was (19.7+/-5.3) degrees, Gissane angle was (137.3+/-7.5) degrees. The postoperative X-ray film demonstrated that Böhler angle was (32.6+/-3.7) degrees, Gissane angle was (125.4+/-2.9) degrees. There was a significant difference between preoperative and postoperative (P<0.01). The average Maryland score was 96.3+/-2.4 (range, 92 to 100 points). Percutaneous reduction and Kirschner pin fixation is an effective minimally invasive way to treat intraarticular fractures of the calcaneus in children, it has many advantages such as minimal invasion, reliable fixation and satisfactory effects.

  5. Management of simple (types A and B) closed tibial shaft fractures using percutaneous lag-screw fixation and Ilizarov external fixation in adults.

    PubMed

    El-Sayed, Mohamed; Atef, Ashraf

    2012-10-01

    Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.

  6. Part II: arthroscopic treatment of tibial plateau fractures: intercondylar eminence avulsion fractures.

    PubMed

    Lubowitz, James H; Elson, Wylie S; Guttmann, Dan

    2005-01-01

    Arthroscopic reduction and internal fixation (ARIF) of tibial intercondylar eminence fractures is the emerging state-of-the-art. ARIF is recommended for displaced type III fractures and should be considered for all cases of displaced type II fractures. Fractures without displacement after closed reduction require careful evaluation to rule out meniscal entrapment. Subjective results of ARIF are uniformly excellent, despite reports of objective anteroposterior laxity. Early range-of-motion exercises are essential to prevent loss of extension. Repair using nonabsorbable suture fixation, when of adequate strength to allow early range-of-motion, has the advantages of eliminating the risks of comminution of the fracture fragment, posterior neurovascular injury, and need for hardware removal, compared with ARIF using screws.

  7. Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The 'fix and shift' technique.

    PubMed

    Ramasamy, P R

    2017-01-01

    Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

  8. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.

    PubMed

    Costa, Matthew L; Achten, Juul; Parsons, Nick R; Rangan, Amar; Griffin, Damian; Tubeuf, Sandy; Lamb, Sarah E

    2014-08-05

    To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. 18 trauma centres in the United Kingdom. 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient's experience of pain and disability to give a score out of 100. disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was -1.3, 95% confidence interval -4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. Current Controlled Trials ISCRTN 31379280. UKCRN 8956. © Costa et al 2014.

  9. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures.

    PubMed

    Gali, Rajasekhar; Devireddy, Sathya Kumar; Venkata, Kishore Kumar Rayadurgam; Kanubaddy, Sridhar Reddy; Nemaly, Chaithanyaa; Dasari, Mallikarjuna

    2016-01-01

    Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP) approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a) the ease of access for retrieval, reimplantation and fixation of the proximal segment; b) the postoperative approach related complications; c) the adequacy of anatomical reduction and stability of fixation; d) the occlusal changes; and the e) TMJ function and radiological changes. Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch) palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby permitting perpendicular placement of screws with minimal risk of damage to the facial nerve.

  10. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures

    PubMed Central

    Gali, Rajasekhar; Devireddy, Sathya Kumar; Venkata, Kishore Kumar Rayadurgam; Kanubaddy, Sridhar Reddy; Nemaly, Chaithanyaa; Dasari, Mallikarjuna

    2016-01-01

    Introduction: Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. Purpose: This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP) approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. Patients and Methods: This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a) the ease of access for retrieval, reimplantation and fixation of the proximal segment; b) the postoperative approach related complications; c) the adequacy of anatomical reduction and stability of fixation; d) the occlusal changes; and the e) TMJ function and radiological changes. Results: Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch) palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. Conclusion: The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby permitting perpendicular placement of screws with minimal risk of damage to the facial nerve. PMID:27274123

  11. 21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...

  12. 21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...

  13. 21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...

  14. 21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...

  15. 21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...

  16. Rib Fracture Fixation: Indications and Outcomes.

    PubMed

    Senekjian, Lara; Nirula, Raminder

    2017-01-01

    Rib fractures are a frequently identified injury in the trauma population. Not only are multiple rib fractures painful, but they are associated with an increased risk of adverse outcomes. Pneumonia in particular can be devastating, especially to an elderly patient, but other complications such as prolonged ventilation and increased intensive care and hospital durations of stay have a negative impact on the patient. Computed tomography scan is the best modality to diagnosis rib fractures but the treatment of fractures is still evolving. Currently patient care involves a multidisciplinary approach that includes pain control, aggressive pulmonary therapy, and possibly surgical fixation. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Biomechanical concepts applicable to minimally invasive fracture repair in small animals.

    PubMed

    Chao, Peini; Lewis, Daniel D; Kowaleski, Michael P; Pozzi, Antonio

    2012-09-01

    Understanding the basic biomechanical principles of surgical stabilization of fractures is essential for developing an appropriate preoperative plan as well as making prudent intraoperative decisions. This article aims to provide basic biomechanical knowledge essential to the understanding of the complex interaction between the mechanics and biology of fracture healing. The type of healing and the outcome can be influenced by several mechanical factors, which depend on the interaction between bone and implant. The surgeon should understand the mechanical principles of fracture fixation and be able to choose the best type of fixation for each specific fracture. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. A protocol for treatment of unstable ankle fractures using transarticular fixation in patients with diabetes mellitus and loss of protective sensibility.

    PubMed

    Jani, Mihir M; Ricci, William M; Borrelli, Joseph; Barrett, Susan E; Johnson, Jeffrey E

    2003-11-01

    Surgical treatment of ankle fractures in patients with diabetes mellitus is associated with a high complication rate. Diabetic patients with peripheral neuropathy are a particularly difficult group to treat because of their inability to sense deep infection, repeat trauma, and wound complications. The purpose of this study was to evaluate a protocol that included transarticular fixation and prolonged, protected weightbearing in the treatment of unstable ankle fractures in diabetic patients with peripheral neuropathy and loss of protective sensibility. The authors retrospectively reviewed the records of 15 patients with diabetes mellitus, unstable ankle fractures (AO classification 44B), and loss of protective sensibility confirmed via testing with a 5.07 Semmes-Weinstein monofilament. Retrograde transcalcaneal-talar-tibial fixation using large Steinmann pins or screws in conjunction with standard techniques of open reduction and internal fixation was used. The postoperative treatment protocol included: 1) short leg, total contact casting and nonweightbearing status for 12 weeks; 2) removal of the intramedullary implants between 12 and 16 weeks; 3) application of a walker boot or short leg cast with partial weightbearing for an additional 12 weeks; and 4) transition to a custom-molded ankle-foot orthosis (AFO) or custom total-contact inserts in appropriate diabetic footwear. The major complication rate for all fractures was 25% (4/16) and for closed fractures was 23% (3/13). These are lower than previously reported rates between 30% (3/10) and 43% (9/21) for diabetic patients with and without neuropathy. The amputation rate for all fractures was 13% (2/16) and for closed fractures alone was 8% (1/13). These are similar to previously reported rates of 10% (2/10) to 20% (2/21). There were no deaths or Charcot malunions in this series. The combination of transarticular fixation and prolonged, protected weightbearing provided 13 of 15 patients with a stable ankle for weightbearing. Although these fractures remain a treatment challenge, this study presents a successful, multidisciplinary protocol for treatment of unstable ankle fractures in the most challenging group of diabetic patients - those with loss of protective sensibility.

  19. Clinical comparative analysis on unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation.

    PubMed

    Li, C-L

    2014-01-01

    To investigate clinical efficacy of unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation. 64 patients with unstable pelvic fractures were selected in the hospital from January 2008 to June 2011, and were randomly divided into two groups.(32 patients with sacroiliac anterior plate fixation as the control group, and another 32 patients with percutaneous sacroiliac screw internal fixation as the observation group). The perioperative period clinical indicators, postoperative Matta score, postoperative Majeed function score of all patients were compared and analyzed. The operation time, intraoperative blood loss, wound total length, postoperative fever time, duration of hospitalization in the observation group were significantly less than those in the control group. The complication rate (3.1%) in the observation group was lower than that in the control group (21.9%). The rate of Matta score excellent (96.9%) in the observation group was higher than that in the control group (81.2%) after the treatment. The rate of Majeed function score excellent (93.8%) in the observation group was significantly higher than that in the control group (75%) after the treatment. Percutaneous sacroiliac screw internal fixation in the treatment of unstable pelvic fractures has less injury, less bleeding, less pain and rapid recovery which is a safe and effective minimally invasive operation method. The clinical curative effect of percutaneous sacroiliac screw internal fixation is better than anterior plate fixation for the treatment of sacroiliac joint. The full preparation before the surgery and patients with positive can substantially reduce the occurrence of complications rate.

  20. Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures.

    PubMed

    Griffiths, Jamie T; Taheri, Arash; Day, Robert E; Yates, Piers J

    2015-12-01

    The aim of this study was to biomechanically evaluate the Locking attachment plate (LAP) construct in comparison to a Cable plate construct, for the fixation of periprosthetic femoral fractures after cemented total hip arthroplasty. Each construct incorporated a locking compression plate with bi-cortical locking screws for distal fixation. In the Cable construct, 2 cables and 2 uni-cortical locking screws were used for proximal fixation. In the LAP construct, the cables were replaced by a LAP with 4 bi-cortical locking screws. The LAP construct was significantly stiffer than the cable construct under axial load with a bone gap (P=0.01). The LAP construct offers better axial stiffness compared to the cable construct in the fixation of comminuted Vancouver B1 proximal femoral fractures. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  1. Treatment of Mandibular Condyle Fractures Using a Modified Transparotid Approach via the Parotid Mini-Incision: Experience with 31 Cases

    PubMed Central

    Shi, Jun; Yuan, Hao; Xu, Bing

    2013-01-01

    Surgery for mandibular condyle fractures must allow direct vision of the fracture, reduce surgical trauma and achieve reduction and fixation while avoiding facial nerve injury. This prospective study was conducted to introduce a new surgical approach for open reduction and internal fixation of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision, and surgical outcomes were evaluated. The modified transparotid approach via the parotid mini-incision was applied and rigid internal fixation using a small titanium plate was carried out for 36 mandibular condyle fractures in 31 cases. Postoperative follow-up of patients ranged from 3 to 26 months; in the first 3 months after surgery, outcomes for all patients were analyzed by evaluating the degree of mouth opening, occlusal relationship, facial nerve function and results of imaging studies. The occlusal relationships were excellent in all patients and none had symptoms of intraoperative ipsilateral facial nerve injury. The mean degree of mouth opening was 4.0 (maximum 4.8 cm, minimum 3.0 cm). No mandibular deviations were noted in any patient during mouth opening. CT showed complete anatomical reduction of the mandibular condyle fracture in all patients. The modified transparotid approach via the smaller, easily concealed parotid mini-incision is minimally invasive and achieves anatomical reduction and rigid internal fixation with a simplified procedure that directly exposes the fracture site. Study results showed that this procedure is safe and feasible for treating mandibular condyle fracture, and offers a short operative path, protection of the facial nerve and satisfactory aesthetic outcomes. PMID:24386221

  2. [Treatment of linguiform calcaneus fracture by close nail-pry reduction and internal fixation with hollow screws].

    PubMed

    Tu, Shu-Qiang; Huang, Ke-Di; Shuai, Yong-Ming; Xu, Nan-Yun; Yuan, Qiu-Wen; Guo, Jian

    2012-06-01

    To study the curative effects of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture. From May 2006 to October 2009,32 patients (35 feet) with linguiform calcaneus fracture were treated by close nail-pry reduction and internal fixation with hollow screws, including 23 males and 9 females ranging in age from 25 to 46 years, with a mean of 37.6 years. According to Paley classification, 3 cases were Paley II a, and 29 cases were Paley II b. All cases were close fractures. The time from injury to operation was 3 to 10 days after most swelling subsided. Böhler angle and Gissane angle were measured by X-ray before and after operation. The therapeutic effect was assessed according to ZHANG Tie-liang's foot score. All the patients were followed-up for 6 to 18 months, with a mean of 12 months. All fractures gained bone healing. The time of fracture healing averaged 12 months. The fractures healed completely and no infection occurred. According to ZHANG Tie-liang's foot scale, the postoperative function was excellent in 18 feet, good in 10 feet, moderate in 5 feet and poor in 2 feet. The Böhler angle and Gissane angle were significant improved after treatment (P < 0.01). The surgical method of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture can regain the foot function, with minimal injury, fewer complications, earlier recovery and lower costs.

  3. The role of internal fixation for long bone metastasis prior to impending fracture: an experimental model.

    PubMed

    Ibrahim, Mohammad; Terai, Hidetomi; Yamada, Kentaro; Suzuki, Akinobu; Toyoda, Hiromitsu; Nakamura, Hiroaki

    2013-07-01

    Patients with long bone metastasis have many therapeutic options, including surgery. However, the appropriate time for surgical intervention and the use of internal fixation prior to impending fracture remains controversial. The purpose of this study was to establish a long bone metastatic model with internal fixation, and to determine whether prophylactic internal fixation for long bone metastasis prior to impending fracture would affect bone destruction, tumor progression, and mortality. We implanted VX2 tumor cells into the tibiae of 45 rabbits divided equally into three groups: internal fixation, control, and sham groups. Rabbits were monitored by X-ray and computed tomography, and blood serum levels were examined every 2 weeks. Computed tomography data revealed significantly higher bone destruction in rabbit tibiae in the sham and control groups compared with those in the fixation group; there were volumetric bone losses of 0.2, 0.4, and 2.3% in the fixation, sham, and control groups, respectively, at 3 weeks, which increased to 1.2, 2.5, and 6.1% at 5 weeks. Rabbits in the fixation group showed significantly prolonged survival (64.5 ± 13.5 days) in comparison with rabbits in the sham group (50.3 ± 11.6 days) and control group (38.2 ± 4.9 days). Our results suggest that prophylactic internal fixation may hinder bone destruction and tumor progression, thus extending the survival period for patients with long bone metastasis.

  4. Femoral osteochondral fracture--a non-contact injury in martial arts? A case report.

    PubMed Central

    Mbubaegbu, C E; Percy, A J

    1994-01-01

    A report of a case of osteochondral fracture of the lateral femoral condyle in a patient doing a karate kick. The problems related to fixation of osteochondral fragments with protruding screws are highlighted and the suitability of Herbert screw fixation noted. Images Figure 1 Figure 2 Figure 3 PMID:8000822

  5. Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis.

    PubMed

    Darwich, Mhd Ayham; Albogha, Mhd Hassan; Abdelmajeed, Adnan; Darwich, Khaldoun

    2016-04-01

    The aim of this study was to compare the performances of 5 plating techniques for fixation of unilateral mandibular subcondylar fracture. Five titanium plating techniques for fixation of condylar fracture were analyzed using the finite element method. The modeled techniques were 1) 1 straight plate, 2) 2 parallel straight plates, 3) 2 angulated straight plates, 4) 1 trapezoidal plate, and 5) 1 square plate. Three-dimensional models were generated using patient-specific geometry for the mandible obtained from a computerized tomographic image of a healthy living man. Plates were designed and combined with the mandible and analyzed under a 500-N load. The single straight plate presented the most inferior performance; it presented maximum displacement and strain on cortical bone. The trapezoidal plate induced the least amount of strain on cortical bone and was best at resisting displacement. The trapezoidal plate is recommended for fixation of subcondylar fracture. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Joint Distraction Treatments of Intra-Articular Fracture-Induced Posttraumatic Osteoarthritis in a Large Animal Model

    DTIC Science & Technology

    2017-10-01

    that was developed this Year for use in the upcoming Aim 2 studies. 15. SUBJECT TERMS External Fixator, Fracture Fixation Delay, Yucatan Minipig 16... Yucatan minipig model of PTOA after IAF that was developed during our previous work (W81XWH-10-1-0864) to investigate the use of joint distraction to...proactive treatment for PTOA. 2. KEYWORDS Post-traumatic Osteoarthritis Intra-articular Fracture Yucatan Miniature Pig Impact Ankle Cartilage

  7. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  8. A Biomechanical Comparison of Three 1.5-mm Plate and Screw Configurations and a Single 2.0-mm Plate for Internal Fixation of a Mandibular Condylar Fracture

    PubMed Central

    Aquilina, Peter; Parr, William C.H.; Chamoli, Uphar; Wroe, Stephen; Clausen, Philip

    2014-01-01

    The most stable pattern of internal fixation for mandibular condyle fractures is an area of ongoing discussion. This study investigates the stability of three patterns of plate fixation using readily available, commercially pure titanium implants. Finite element models of a simulated mandibular condyle fracture were constructed. The completed models were heterogeneous in bone material properties, contained approximately 1.2 million elements and incorporated simulated jaw adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. No human subjects were involved in this investigation. The stability of the simulated condylar fracture reduced with the different implant configurations, and the von Mises stresses of a 1.5-mm X-shaped plate, a 1.5-mm rectangular plate, and a 1.5-mm square plate (all Synthes (Synthes GmbH, Zuchwil, Switzerland) were compared. The 1.5-mm X plate was the most stable of the three 1.5-mm profile plate configurations examined and had comparable mechanical performance to a single 2.0-mm straight four-hole plate. This study does not support the use of rectangular or square plate patterns in the open reduction and internal fixation of mandibular condyle fractures. It does provide some support for the use of a 1.5-mm X plate to reduce condylar fractures in selected clinical cases. PMID:25136411

  9. Complications and early results after operative fixation of 68 pilon fractures of the distal tibia.

    PubMed

    Lomax, Adam; Singh, Anjani; N Jane, Madeley; C Senthil, Kumar

    2015-05-01

    In this cohort study, we present comprehensive injury specific and surgical outcome data from one of the largest reported series of pilon fractures of the distal tibia treated in a UK tertiary referral centre. A series of 68 closed pilon fractures were retrospectively reviewed from case notes, plain radiographs and computed tomography imaging. Patient demographics, injury and fracture patterns, methods and timing of fixation and clinical and radiological outcomes were assessed over a mean follow-up period of 7.7 months (1.5-30). Overall, deep infection occurred in 1.6% with superficial infection and wound breakdown occurring in 6.3% of cases. Rates of nonunion and malunion were 7.8%. Radiological posttraumatic arthritis was present in 26.6%, which was symptomatic and requiring orthopaedic management in 9.4%. Further surgery for all causes occurred in 26.6% of cases. Fixation of these complex fractures in subspecialist units can achieve overall low rates of wound complications, with definitive fixation of selected fractures within 48 h of initial presentation achieving comparable results to those fixed in a delayed fashion. However, this injury continues to have a significant overall complication rate with a high chance of developing early posttraumatic arthritis and of requiring further surgery. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Temporary short-segment pedicle screw fixation for thoracolumbar burst fractures: comparative study with or without vertebroplasty.

    PubMed

    Aono, Hiroyuki; Ishii, Keisuke; Tobimatsu, Hidekazu; Nagamoto, Yukitaka; Takenaka, Shota; Furuya, Masayuki; Chiaki, Horii; Iwasaki, Motoki

    2017-08-01

    Short-segment posterior spinal instrumentation for thoracolumbar burst fracture provides superior correction of kyphosis by an indirect reduction technique, but it has a high failure rate. The purpose of the study we report here was to compare outcomes for temporary short-segment pedicle screw fixation with vertebroplasty and for such fixation without vertebroplasty. This is a prospective multicenter comparative study. We studied 62 consecutive patients with thoracolumbar burst fracture who underwent short-segment posterior instrumentation using ligamentotaxis with Schanz screws with or without vertebroplasty. Radiological parameters (Cobb angle on standing lateral radiographs) were used. Implants were removed approximately 1 year after surgery. Neurologic function, kyphotic deformity, canal compromise, and fracture severity were evaluated prospectively. After surgery, all patients with neurologic deficit had improvement equivalent to at least one grade on the American Spinal Injury Association impairment scale and had fracture union. Kyphotic deformity was reduced significantly, and reduction of the vertebrae was maintained with and without vertebroplasty, regardless of load-sharing classification. Although no patient required additional anterior reconstruction, kyphotic change was observed at disc level mainly after implant removal with or without vertebroplasty. Temporary short-segment fixation yielded satisfactory results in the reduction and maintenance of fractured vertebrae with or without vertebroplasty. Kyphosis recurrence may be inevitable because adjacent discs can be injured during the original trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Treatment of close-range, low-velocity gunshot fractures of tibia and femur diaphysis with consecutive compression-distraction technique: a report of 11 cases.

    PubMed

    Ateşalp, A Sabri; Kömürcü, Mahmut; Demiralp, Bahtiyar; Bek, Dogan; Oğuz, Erbil; Yanmiş, Ibrahim

    2004-01-01

    Lower extremity injuries secondary to close-range, low-velocity gunshot wounds are frequently seen in both civilian and military populations. A close-range, low-velocity injury produces high energy and often results in comminuted and complicated fractures with significant morbidity. In this study, four femoral, four tibial, and three combined tibia and fibular comminuted diaphyseal fractures secondary to close-range, low-velocity gunshot wounds in 11 military personnel were treated with debridement followed by compression-distraction lengthening using a circular external fixator frame. Fracture union was obtained in all without significant major complications. Fracture consolidation occurred at a mean of 3.5 months. At follow-up of 46.8 months, there were no delayed unions, nonunions, or malunions. Minor complications included four pin-tract infections and knee flexion limitation in two femur fractures. Osteomyelitis and deep soft tissue infection were not observed. This technique provided an alternative to casting, open reduction internal fixation, or intermedullary fixation with an acceptable complication rate.

  12. Treatment of open tibial fracture with bone defect caused by high velocity missiles: a case report.

    PubMed

    Golubović, Zoran; Vukajinović, Zoran; Stojiljković, Predrag; Golubović, Ivan; Visnjić, Aleksandar; Radovanović, Zoran; Najman, Stevo

    2013-01-01

    Tibia fracture caused by high velocity missiles is mostly comminuted and followed by bone defect which makes their healing process extremely difficult and prone to numerous complications. A 34-year-old male was wounded at close range by a semi-automatic gun missile. He was wounded in the distal area of the left tibia and suffered a massive defect of the bone and soft tissue. After the primary treatment of the wound, the fracture was stabilized with an external fixator type Mitkovic, with convergent orientation of the pins. The wound in the medial region of the tibia was closed with the secondary stitch, whereas the wound in the lateral area was closed with the skin transplant after Thiersch. Due to massive bone defect in the area of the rifle-missile wound six months after injury, a medical team placed a reconstructive external skeletal fixator type Mitkovic and performed corticotomy in the proximal metaphyseal area of the tibia. By the method of bone transport (distractive osteogenesis), the bone defect of the tibia was replaced. After the fracture healing seven months from the secondary surgery, the fixator was removed and the patient was referred to physical therapy. Surgical treatment of wounds, external fixation, performing necessary debridement, adequate antibiotic treatment and soft and bone tissue reconstruction are essential in achieving good results in patients with the open tibial fracture with bone defect caused by high velocity missiles. Reconstruction of bone defect can be successfully treated by reconstructive external fixator Mitkovic.

  13. Plate fixation versus intramedullary fixation for midshaft clavicle fractures: Meta-analysis of complications and functional outcomes.

    PubMed

    Xiao, Hao; Gao, Hengbo; Zheng, Tuokang; Zhao, Jianhui; Tian, Yingping

    2016-04-01

    This analysis critically compares publications discussing complications and functional outcomes of plate fixation (PF) versus intramedullary fixation (IF) for midshaft clavicle fractures. Relevant studies published between January 1990 and October 2014, without language restrictions, were identified in database searches of PubMed®, Medline®, Embase and the Chinese National Knowledge Infrastructure (CNKI). Studies that compared postoperative complications and functional outcomes between PF and IF for midshaft clavicle fractures, and provided sufficient data for analysis, were included in this meta-analysis. After strict evaluation, 12 studies were included in this meta-analysis. Studies encompassed 462 participants in the PF group and 440 in the IF group. Study participants were followed up for ≥1 year. Outcomes were superior with IF compared with PF in terms of shoulder constant score at 6-month follow-up, fewer symptomatic hardware complications, lower rate of refracture after hardware removal and less hypertrophic scarring. In other aspects, such as functional recovery at 12-months and 24-months, Disability of Arm, Shoulder and Hand (DASH) questionnaire results at 12-month follow-up, shoulder motion range, rates of superficial infection, temporary brachial plexus lesion, nonunion, malunion, delayed union, implant failure and need for major revision, both techniques were similar. Findings of this meta-analysis suggest that, in many respects, IF was superior to PF for the management of midshaft clavicle fractures. This finding could aid surgeons in making decisions on the optimum internal fixation pattern for midshaft clavicular fractures. © The Author(s) 2016.

  14. Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography.

    PubMed

    Endo, Jun; Yamaguchi, Satoshi; Saito, Masahiko; Morikawa, Tsuguo; Akagi, Ryuichiro; Sasho, Takahisa

    2016-10-01

    To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. The mean anterior tibiofibular distance was 0.7mm after syndesmotic fixation. It increased to 1.9mm at one year after screw removal (p=0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1mm vs. 0.6mm for the posterior tibiofibular distance, 0.2mm vs. 0.3mm for the anteroposterior fibular translation, and 0.7° vs. 0° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation (p=0.01) and from 20% to 60% at one year after screw removal (p=0.02). The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. Copyright © 2016. Published by Elsevier Ltd.

  15. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation.

    PubMed

    Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas

    2008-02-01

    Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.

  16. Immediate mobilization following fixation of mandible fractures: a prospective, randomized study.

    PubMed

    Kaplan, B A; Hoard, M A; Park, S S

    2001-09-01

    To compare outcomes of open reduction and internal fixation of displaced mandible fractures followed by either immediate mobilization or 2 weeks of mandibular-maxillary fixation. A prospective, randomized, single-blinded study was performed. The study was performed between January 1, 1997, and March 30, 2000. Inclusion criteria were displaced fractures between the mandibular angles, age greater than 16 years, and no involvement of the alveolus, ramus, condyles, or maxilla. All fractures were repaired by means of open reduction and internal fixation using 2.0-mm titanium plates secured either in transoral fashion or percutaneously. Data were collected at 6-week and 3- and 6-month postoperative examinations. Variables were assessed by a surgeon blinded to the history of immobilization and included pain, malunion or nonunion, occlusion, trismus, wound status, infection rates, dental hygiene, and weight loss. Twenty-nine consecutive patients were enrolled, 16 patients to immediate function and 13 patients to 2 weeks of mandibular-maxillary fixation. No statistically significant differences were found between groups for any of the variables. Immediate release and temporary immobilization showed mean weight loss of 10 and 8 pounds and trismus of 4.2 and 4.6 cm, respectively. One wound separation and one infection were seen in the immobilization population, and no wound separation or infection was seen in the immediate-release group. Dental hygiene was similar between the groups. No malunion or nonunion was noted in either group. In this prospective and randomized study, no significant differences were noted between the groups receiving either immediate release or 2 weeks of mandibular-maxillary fixation. The findings support the treatment of selective mandible fractures with 2.0-mm miniplates and immediate mobilization.

  17. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  18. Percutaneous reduction and fixation of an intra-articular calcaneal fracture using an inflatable bone tamp: description of a novel and safe technique

    PubMed Central

    2012-01-01

    Calcaneal fractures are common injuries involving the hind foot and often a source of significant long-term morbidity. Treatment options have changed throughout the ages from periods of preferred nonoperative management to closed reduction with a mallet, and more recently, open reduction and anatomic internal fixation. The current treatment of choice; however, is often debated, as open management of these fractures carries many risks to include wound breakdown and infection. A less invasive form of surgical management through small incisions, while maintaining the ability to obtain joint congruency, anatomic alignment, and restore calcaneal height and width would be ideal. We propose a novel form of fracture reduction using an inflatable bone tamp and percutaneous fracture fixation. Preoperative planning and experienced fluoroscopy is crucial to successful management using this method. Although we achieved successful radiographic outcome in this case, long-term functional outcome of this technique are yet to be published. PMID:22420710

  19. Radiologic Changes by Early Motion in Neck Fractures of the Fifth Metacarpal Treated with Antegrade Intramedullary Fixation.

    PubMed

    Heo, Youn Moo; Kim, Sang Bum; Yi, Jin Woong; Kim, Tae Gyun; Lim, Byoung Gu

    2016-02-01

    As intramedullary (IM) fixation is one of the fixation methods used in neck fractures of the fifth metacarpal, an early motion of injured finger can be allowed. The purpose of this study is to evaluate whether immediate active motion affects the stability of antegrade IM fixation in surgical treatment of neck fractures of the fifth metacarpal bone and to assess related factors. Thirty one patients treated by closed reduction and antegrade IM fixation were consecutively enrolled. All patients started active motion of the little finger since 7 postoperative days and only daily activities including writing, typing or washing were allowed until the union of fracture. All fractures were healed within four to eight weeks. The changes of angulation, fifth metacarpal length and tip to head distance of K-wire were compared between immediate postoperative radiographs and radiographs at eight weeks. In addition, the effects by age, gender, initial angulation and comminution of the metacarpal neck were assessed. The average change of angulation was 0.12°, 5th metacarpal length was 1.49mm and tip to head distance of K-wire was 1.31mm. There was no significant difference in the change of angulation (p = 0.137). But, there were significant differences in the change of 5th metacarpal length and tip to head distance of K-wire ([Formula: see text]). The change of angulation was related to a comminution of the metacarpal neck and that of 5th metacarpal length was related to age and sex. The change of 5th metacarpal length and tip to head distance of K-wire can occur by an early mobilization in the antegrade IM fixation for neck fractures of the fifth metacarpal. However, we thought that an early active motion after surgery is important to increase the patients' satisfaction, even though careful selection of candidates is necessary.

  20. The initial safe range of motion of the ankle joint after three methods of internal fixation of simulated fractures of the medial malleolus.

    PubMed

    Shimamura, Yoshio; Kaneko, Kazuo; Kume, Kazuhiko; Maeda, Mutsuhiro; Iwase, Hideaki

    2006-07-01

    Previous studies have demonstrated the safe passive range of ankle motion for inter-bone stiffness after internal fixation under load but there is a lack of information about the safe range of ankle motion for early rehabilitation in the absence of loading. The present study was designed to assess the effect of ankle movement on inter-bone displacement characteristics of medial malleolus fractures following three types of internal fixation to determine the safe range of motion. Five lower legs obtained during autopsy were used to assess three types of internal fixation (two with Kirschner-wires alone; two with Kirschner-wires plus tension band wiring; and, one with an AO/ASIF malleolar screw alone). Following a simulated fracture by sawing through the medial malleolus the displacement between the fractured bone ends was measured during a passive range of movement with continuous monitoring using omega (Omega) shaped transducers and a biaxial flexible goniometer. Statistical analysis was performed with repeated measures analysis of variance. Inter-bone displacement was not proportional to the magnitude of movement throughout the range of ankle motion as, when separation exceeded 25 microm, there was increasingly wide separation as plantar-flexion or dorsal-flexion was increased. There was no statistical significant difference between the small amount of inter-bone displacement observed with three types of fixation within the safe range of dorsal-flexion and plantar-flexion for early rehabilitation. However the inter-bone separation when fixation utilized two Kirschner-wires alone tended to be greater than when using the other two types of fixation during dorsal-flexion and eversion. The present study revealed a reproducible range of ankle motion for early rehabilitation which was estimated to be within the range of 20 degrees of dorsal-flexion and 10 degrees of plantar-flexion without eversion. Also, internal fixation with two Kirschner-wires alone does not seem to provide stability achieved by the other two forms of fixation.

  1. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study

    PubMed Central

    Bali, Rishi K.; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-01-01

    Aims: The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. Materials and Methods: This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Results: Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Conclusions: Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required. PMID:24665170

  2. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

    PubMed

    Bali, Rishi K; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-07-01

    The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required.

  3. Maxillomandibular Fixation by Plastic Surgeons: Cost Analysis and Utilization of Resources.

    PubMed

    Farber, Scott J; Snyder-Warwick, Alison K; Skolnick, Gary B; Woo, Albert S; Patel, Kamlesh B

    2016-09-01

    Maxillomandibular fixation (MMF) can be performed using various techniques. Two common approaches used are arch bars and bone screws. Arch bars are the gold standard and inexpensive, but often require increased procedure time. Bone screws with wire fixation is a popular alternative, but more expensive than arch bars. The differences in costs of care, complications, and operative times between these 2 techniques are analyzed. A chart review was conducted on patients treated over the last 12 years at our institution. Forty-four patients with CPT code 21453 (closed reduction of mandible fracture with interdental fixation) with an isolated mandible fracture were used in our data collection. The operating room (OR) costs, procedure duration, and complications for these patients were analyzed. Operative times were significantly shorter for patients treated with bone screws (P < 0.002). The costs for one trip to the OR for either method of fixation did not show any significant differences (P < 0.840). More patients with arch bar fixation (62%) required a second trip to the OR for removal in comparison to those with screw fixation (31%) (P < 0.068). This additional trip to the OR added significant cost. There were no differences in patient complications between these 2 fixation techniques. The MMF with bone screws represents an attractive alternative to fixation with arch bars in appropriate scenarios. Screw fixation offers reduced costs, fewer trips to the OR, and decreased operative duration without a difference in complications. Cost savings were noted most significantly in a decreased need for secondary procedures in patients who were treated with MMF screws. Screw fixation offers potential for reducing the costs of care in treating patients with minimally displaced or favorable mandible fractures.

  4. Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study.

    PubMed

    Landgren, Marcus; Abramo, Antonio; Geijer, Mats; Kopylov, Philippe; Tägil, Magnus

    2017-03-01

    To compare the patient-reported, clinical, and radiographic outcome of 2 methods of internal fixation in distal radius fractures. Fifty patients, mean age 56 years (range, 21-69 years) with primarily nonreducible or secondarily redisplaced distal radius fractures were randomized to open reduction internal fixation using volar locking plates (n = 25) or fragment-specific fixation (n = 25). The patients were assessed on grip strength, range of motion, patient-reported outcome (Quick Disabilities of the Arm, Shoulder, and Hand), pain (visual analog scale), health-related quality of life (Short Form-12 [SF-12]), and radiographic evaluation. Grip strength at 12 months was the primary outcome measure. At 12 months, no difference was found in grip strength, which was 90% of the uninjured side in the volar plate group and 87% in the fragment-specific fixation group. No differences were found in range of motion and the median Quick Disabilities of the Arm, Shoulder, and Hand score was 5 in both groups. The overall complication rate was significant, 21% in the volar locking plate group, compared with 52% in the fragment-specific group. In treatment of primarily nonreducible or secondarily redisplaced distal radius fractures, volar locking plates and fragment-specific fixation both achieve good and similar patient-reported outcomes, although more complications were recorded in the fragment-specific group. Therapeutic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. [Staple fixation for the treatment of hamate metacarpal joint injury].

    PubMed

    Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da

    2014-03-01

    To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.

  6. Management of distal femoral periprosthetic fractures by distal femoral locking plate: A retrospective study.

    PubMed Central

    Thukral, Rajiv; Marya, SKS; Singh, Chandeep

    2015-01-01

    Background: Management of periprosthetic supracondylar femoral fractures is difficult. Osteoporosis, comminution and bone loss, compromise stability with delayed mobility and poor functional outcomes. Open reduction and internal fixation (ORIF) with anatomic distal femoral (DF) locking plate permits early mobilization. However, this usually necessitates bone grafting (BG). Biological fixation using minimally invasive techniques minimizes periosteal stripping and morbidity. Materials and Methods: 31 patients with comminuted periprosthetic DF fractures were reviewed retrospectively from October 2006 to September 2012. All patients underwent fixation using a DF locking compression plate (Synthes). 17 patients underwent ORIF with primary BG, whereas 14 were treated by closed reduction (CR) and internal fixation using biological minimally invasive techniques. Clinical and radiological followup were recorded for an average 36 months. Results: Mean time to union for the entire group was 5.6 months (range 3-9 months). Patients of ORIF group took longer (Mean 6.4 months, range 4.5-9 months) than the CR group (mean 4.6 months, range 3-7 months). Three patients of ORIF and one in CR group had poor results. Mean knee society scores were higher for CR group at 6 months, but nearly identical at 12 months, with similar eventual range of motion. Discussion: Locked plating of comminuted periprosthetic DF fractures permits stable rigid fixation and early mobilization. Fixation using minimally invasive biological techniques minimizes morbidity and may obviate the need for primary BG. PMID:26015610

  7. [Management of displaced radial neck fractures in children: elastic stable intramedullary nailing vs K-wire fixation].

    PubMed

    Wu, Quan-Zhou; Huang, Shu-Ming; Cai, Qi-Xun; Chu, Xu-Feng

    2017-01-25

    To compare the complications and clinical outcome of titanium elastic nail(TEN) versus K-wire fixation(KW) for the treatment of displaced radial neck fractures in children. From January 2009 to December 2014, 56 children with displaced radial neck fractures were studied retrospectively according to the inclusion criteria. Based on the different methods of internal fixation, patients were divided into two groups: titanium elastic nail (TEN group) and K-wire fixation (KW group). Among 25 patients(15 males and 11 females, aged from 3 to 12 years old with an average of 8.6±2.1) treated with TEN, 16 patients had type III fractures, 19 patients had type IV fractures according to Metaizeau-Judet modified classification; 20 patients were treated with closed reduction and 5 patients were treated with open reduction; the time from injury to treatment ranged from 1 to 8 days with an average of (3.6±1.7) days. Among 31 patients (20 males and 11 females, aged from 3 to 11 years old with an average of 9.1±1.9 years old) treated with KW, 19 patients had type III fractures, 12 patients had type IV fractures; 22 patients were treated with closed reduction, and 9 patients were treated with open reduction; the time from injury to treatment ranged from 2 to 7 days with an average of (3.7±1.5) days. No significant differences between two groups were found in general data. Operative time, hospitalization time, healing time of fracture, internal fixation time, postoperative complications and function recovery of the two groups were compared and evaluated. The average follow-up period of the patients was 22.1 months in TEN group(ranged, 16 to 48 months), and 21.9 months in KW group(ranged, 13 to 48 months). There were no significant differences between these 2 groups in follow-up duration, average hospitalization time and fracture healing time. The operation time, hospital costs and internal fixation time in TEN group were (56.6±11.8) min, (18 000±3 000) Yuan(RMB), (9.1±2.5) weeks respectively; and in KW group were(45.5±10.3) min, (8 000±1 000) Yuan(RMB), (4.8±1.6) weeks respectively, there were significant differences between two groups( P <0.05). Outcome scores according to Metaizeau and Tibone-Stoltz had no significant differences between two groups( P >0.05). There is no significant difference of therapeutic effects between TEN and KW for children with displaced radial neck fractures. Because the removal of TEN fixation requires the secondary anesthesia, and the TEN costs significantly more than KW, TEN still can't replace the traditional KW for the treatment of radial neck fracture in children.

  8. [Fat embolism syndrome following lower limb fracture despite rapid external fixation. Two case reports and review of the literature].

    PubMed

    Kleinert, K; Marug, D; Soklic, P; Simmen, H-P

    2009-09-01

    Fat embolism syndrome (FES) is a rare complication occurring in 0.9-2.2% of patients following long bone fractures. Patients present with a classical triad of respiratory manifestations, cerebral effects and petechiae. The incidence of FES is reduced by early immobilization of fractures and by minimally invasive operative management. Nevertheless, two healthy young men suffered from FES after immediate (within 3 h after trauma) external fixation of lower leg fractures. This postoperative complication should always be considered even after conservative or minimally invasive therapy.

  9. The floating knee: a review on ipsilateral femoral and tibial fractures

    PubMed Central

    Muñoz Vives, Josep; Bel, Jean-Christophe; Capel Agundez, Arantxa; Chana Rodríguez, Francisco; Palomo Traver, José; Schultz-Larsen, Morten; Tosounidis, Theodoros

    2016-01-01

    In 1975, Blake and McBryde established the concept of ‘floating knee’ to describe ipsilateral fractures of the femur and tibia.1 This combination is much more than a bone lesion; the mechanism is usually a high-energy trauma in a patient with multiple injuries and a myriad of other lesions. After initial evaluation patients should be categorised, and only stable patients should undergo immediate reduction and internal fixation with the rest receiving external fixation. Definitive internal fixation of both bones yields the best results in almost all series. Nailing of both bones is the optimal fixation when both fractures (femoral and tibial) are extra-articular. Plates are the ‘standard of care’ in cases with articular fractures. A combination of implants are required by 40% of floating knees. Associated ligamentous and meniscal lesions are common, but may be irrelevant in the case of an intra-articular fracture which gives the worst prognosis for this type of lesion. Cite this article: Muñoz Vives K, Bel J-C, Capel Agundez A, Chana Rodríguez F, Palomo Traver J, Schultz-Larsen M, Tosounidis, T. The floating knee. EFORT Open Rev 2016;1:375-382. DOI: 10.1302/2058-5241.1.000042. PMID:28461916

  10. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    PubMed Central

    Facaros, Zacharia; Ramanujam, Crystal L.; Stapleton, John J.

    2010-01-01

    The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws) to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF) of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This techniqu may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss. PMID:22396812

  11. Surgical treatment for pilon fracture of the ankle-open reduction and internal fixation.

    PubMed

    Chen, Y W; Huang, P J; Hsu, C Y; Kuo, C H; Cheng, Y M; Lin, S Y; Chen, L H; Chiang, H C

    1998-01-01

    From 1991 to 1994, 39 ankles of 38 patients underwent surgical open reduction and internal fixation for pilon fractures. These patients included 29 males and 9 females with an average age of 38.6 y/o (range 28 y/o-58 y/o). The follow up and evaluation period averaged 31.7 months (range 22Ms-44Ms), during which time a standing x-ray for arthrosis grading and functional scale was used for clinical evaluation. Complications included 1 case of infection, 1 case of loss reduction, 2 cases of partial skin necrosis and 2 cases of delayed union. Post-traumatic arthritis occurred in 23 ankles (59%) but only 4 ankles of grade 4 arthrosis resulted in poor functional scale and the overall satisfactory rate was 82%. It was found that anatomic reduction, rigid fixation and early motion exercise are important to successful treatment of ankle fractures. Regarding pilon fracture, specifically the severity of fracture pattern and delay of reduction are important problems to overcome to ensure successful results. Therefore, adequate surgical approach for entire view of ankle joint, reduction and fixation of fibula, sufficient bone graft for articular support, intraoperative x-ray check and postoperative immobilization are essential for the achievement of better clinical results.

  12. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis.

    PubMed

    Zhang, Shao-Bo; Zhang, Yi-Bao; Wang, Sheng-Hong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-04-01

    To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the rate of nonunion, malunion/delayed union and the excellent/good rate assessed by Mazur ankle score. The complications including infections and arthritis symptoms after surgery were also investigated. Nine trials including 498 pilon fractures of 494 patients were identified. The meta-analysis found no significant differences in nonunion rate (RR = 1.60, 95% CI: 0.66 to 3.86, p = 0.30), and the excellent/good rate (RR = 0.95, 95% CI: 0.86 to 1.04, p = 0.28) between LIFEF group and ORIF group. For assessment of infections, there were significant differences in the rate of deep infection (RR = 2.18, 95% CI: 1.34 to 3.55, p = 0.002), and the rate of arthritis (RR = 1.26, 95% CI: 1.03 to 1.53, p = 0.02) between LIFEF group and ORIF group. LIFEF has similar effect as ORIF in the treatment of pilon fractures, however, LIFEF group has significantly higher risk of complications than ORIF group does. So LIFEF is not recommended in the treatment of pilon fracture. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  13. Fixed-angle plates in patella fractures - a pilot cadaver study

    PubMed Central

    2011-01-01

    Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years) a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge), quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65). Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays advantages over the established operative procedures. PMID:21345769

  14. [Treatment of thoracolumbar burst fracture with lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh].

    PubMed

    Zhang, Shi-min; Zhang, Zhao-jie; Liu, Yu-zhang; Zhang, Lu-tang; Li, Xing

    2011-11-01

    To discuss the efficacy of lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh in the treatment of severe thoracolumbar burst fracture. From January 2008 to January 2010, 21 patients with severe thoracolumbar burst fracture were treated with lateral anterior decompression, internal fixation with Ventrofix, bone graft with titanic mesh. There were 15 males and 6 females, ranging in age from 21 to 46 years with an average of 32.2 years. Segment of fracture: 3 cases were in T11, 6 cases in T12, 7 cases in L1, 5 cases in L2. The mean kyphosis angle was 20.1 degrees and loading of fracture was 7.8 scores. Twenty-one cases accompany with incomplete paralysis. Nerves functions were observed according to Frankel grade; correction and maintain of kyphosis angle were observed by X-rays and CT. All the patients were followed up from 12 to 34 months with an average of 18.5 years. Postoperative complication including injury of pleura in 1 case, dynamic ileus in 2 cases, ilioinguinal nerve injury in 1 case, faulty union of wound in 1 case. All the above complications got recovery after symptomatic treatment. The mean kyphosis angle in fusional segment were 4.2 degrees and the rate of correction was 79%. Nerves functions of all patients got improvement and no internal fixation fail, kyphosis angle obviously lost, titanium mesh shifting, loosening and breakage of screw were found at final follow-up. Lateral anterior decompression, bone graft with titanic mesh, internal fixation with Ventrofix is an idea technique for severe thoracolumber burst fracture, but the method can not be used for patient with severity osteoporosis.

  15. Percutaneous external fixator pins with bactericidal micron-thin sol-gel films for the prevention of pin tract infection.

    PubMed

    Qu, Haibo; Knabe, Christine; Radin, Shula; Garino, Jonathan; Ducheyne, Paul

    2015-09-01

    Risk of infection is considerable in open fractures, especially when fracture fixation devices are used to stabilize the fractured bones. Overall deep infection rates of 16.2% have been reported. The infection rate is even greater, up to 32.2%, with external fixation of femoral fractures. The use of percutaneous implants for certain clinical applications, such as percutaneous implants for external fracture fixation, still represents a challenge today. Currently, bone infections are very difficult to treat. Very potent antibiotics are needed, which creates the risk of irreversible damage to other organs, when the antibiotics are administered systemically. As such, controlled, local release is being pursued, but no such treatments are in clinical use. Herein, the use of bactericidal micron-thin sol-gel films on metallic fracture fixation pins is reported. The data demonstrates that triclosan (2,4,4'-trichloro-2'-hydroxydiphenylether), an antimicrobial agent, can be successfully incorporated into micron-thin sol-gel films deposited on percutaneous pins. The sol-gel films continuously release triclosan in vitro for durations exceeding 8 weeks (longest measured time point). The bactericidal effect of the micron-thin sol-gel films follows from both in vitro and in vivo studies. Inserting percutaneous pins in distal rabbit tibiae, there were no signs of infection around implants coated with a micron-thin sol-gel/triclosan film. Healing had progressed normally, bone tissue growth was normal and there was no epithelial downgrowth. This result was in contrast with the results in rabbits that received control, uncoated percutaneous pins, in which abundant signs of infection and epithelial downgrowth were observed. Thus, well-adherent, micron-thin sol-gel films laden with a bactericidal molecule successfully prevented pin tract infection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture.

    PubMed

    He, Baorong; Yan, Liang; Zhao, Qinpeng; Chang, Zhen; Hao, Dingjun

    2014-12-01

    Most atlas fractures can be effectively treated nonoperatively with external immobilization unless there is an injury to the transverse atlantal ligament. Surgical stabilization is most commonly achieved using a posterior approach with fixation of C1-C2 or C0-C2, but these treatments usually result in loss of the normal motion of the C1-C2 and C0-C1 joints. To clinically validate feasibility, safety, and value of open reduction and fixation using an atlas polyaxial lateral mass screw-plate construct in unstable atlas fractures. Retrospective review of patients who sustained unstable atlas fractures treated with polyaxial lateral mass screw-plate construct. Twenty-two patients with unstable atlas fractures who underwent posterior atlas polyaxial lateral mass screw-plate fixation were analyzed. Visual analog scale, neurologic status, and radiographs for fusion. From January 2011 to September 2012, 22 patients with unstable atlas fractures were treated with this technique. Patients' charts and radiographs were reviewed. Bone fusion, internal fixation placement, and integrity of spinal cord and vertebral arteries were assessed via intraoperative and follow-up imaging. Neurologic function, range of motion, and pain levels were assessed clinically on follow-up. All patients were followed up from 12 to 32 months, with an average of 22.5±18.0 months. A total of 22 plates were placed, and all 44 screws were inserted into the atlas lateral masses. The mean duration of the procedure was 86 minutes, and the average estimated blood loss was 120 mL. Computed tomography scans 9 months after surgery confirmed that fusion was achieved in all cases. There was no screw or plate loosening or breakage in any patient. All patients had well-preserved range of motion. No vascular or neurologic complication was noted, and all patients had a good clinical outcome. An open reduction and posterior internal fixation with atlas polyaxial lateral mass screw-plate is a safe and effective surgical option in the treatment of unstable atlas fractures. This technique can provide immediate reduction and preserve C1-C2 motion. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Temporal variation of applied inter fragmentary displacement at a bone fracture in harmony with maturation of the fracture callus.

    PubMed

    Gardner, T N; Evans, M; Simpson, H

    1998-09-01

    The amplitude of inter fragmentary displacement in long bone fractures greatly influences the pattern and speed of healing. Unfortunately, the amplitude of natural cyclical displacement arising from patient activity is random because of the inherent flexibility of fixation devices under natural loading. Although fixators may be designed to control the amplitude of this displacement, the amplitudes most beneficial to healing have not been determined. Furthermore, the appropriate amplitude must vary during healing as the reparative tissue (callus) progresses histologically and stiffens during maturation. In this study on an experimental fracture, the amplitude of applied cyclical displacement is varied during healing to correspond with the inverse of the callus stiffness versus time curve. In vivo mechanical stiffness tests on the callus indicate that the end point of the fixation period is achieved more rapidly than with a constant level of applied displacement.

  18. Toxic shock syndrome post open reduction and Kirschner wire fixation of a humeral lateral condyle fracture

    PubMed Central

    Chan, Yuen; Selvaratnam, Veenesh; Garg, Neeraj

    2015-01-01

    Use of Kirschner wires (K-wires) is the most common method of fracture stabilisation in lateral condyle fracture fixation in children. We report a case of toxic shock syndrome (TSS) following an open reduction and internal fixation using K-wires for a humeral lateral condyle fracture in a 5-year-old girl. TSS is a toxin-mediated multisystem illness. It typically presents with shock and it is most often attributed to toxin-producing strains of Staphylococcus aureus and Streptococcus pyogenes. It can lead to multiorgan failure and, ultimately, death. It is important to be aware of TSS, as it can present within any setting. Patients often have non-specific symptoms and their condition can worsen rapidly. TSS postorthopaedic surgery is rare; however, due to the serious nature of this disease, it is important to promptly recognise and diagnose TSS, and to ensure appropriate treatment is started without delay. PMID:26264942

  19. [3-D finite element modeling of internal fixation of mandibular mental fracture and the design of boundary constraints].

    PubMed

    Luo, Xiaohui; Wang, Hang; Fan, Yubo

    2007-04-01

    This study was aimed to develop a 3-D finite element (3-D FE) model of the mental fractured mandible and design the boundary constrains. The CT images from a health volunteer were used as the original information and put into ANSYS program to build a 3-D FE model. The model of the miniplate and screw which were used for the internal fixation was established by Pro/E. The boundary constrains of different muscle loadings were used to simulate the 3 functional conditions of the mandible. A 3-D FE model of mental fractured mandible under the miniplate-screw internal fixation system was constructed. And by the boundary constraints, the 3 biting conditions were simulated and the model could serve as a foundation on which to analyze the biomechanical behavior of the fractured mandible.

  20. Biological approach to treatment of intra-articular proximal tibial fractures with double osteosynthesis.

    PubMed

    Singh, Saurabh; Patel, Pankaj R; Joshi, Anil Kumar; Naik, Rajnikant N; Nagaraj, Chethan; Kumar, Sudeep

    2009-02-01

    The treatment of intra-articular proximal tibial fractures is associated with complications, and much conflicting literature exists concerning the treatment of choice. In our study, an attempt has been made to develop an ideal and adequate treatment protocol for these intra-articular fractures. The principle of double osteosynthesis, i.e., lateral minimally invasive plate osteosynthesis (MIPO), was combined with a medial external fixator to treat 22 intra-articular proximal tibial fractures with soft tissue injury with a mean follow-up of 25 months. Superficial pin track infection was observed in one case, and no soft tissue breakdown was noted. Loss of articular reconstruction was reported in one case. Bridging callus was seen at 12 weeks (8 weeks-7 months). The principle of substitution or double osteosynthesis, i.e., lateral MIPO, was combined with a medial external fixator and proved to be a fairly good method of fixation in terms of results and complications.

  1. Outcome of distal end clavicle fractures treated with locking plates.

    PubMed

    Vaishya, Raju; Vijay, Vipul; Khanna, Vikram

    2017-02-01

    Fractures of the lateral end of the clavicle are relatively uncommon. These fractures are unstable due to the various deforming forces which act on the fragments as well as the small distal fracture fragment. At most times the deforming forces are not taken into consideration, and the fracture is not fixed securely. In this study, we assessed a fixation technique using the precontoured locking plates to find out whether it provided a stable fixation with good functional outcome. Totally, 32 patients with lateral end clavicle fracture (Neer's Type II) were included in the study. After the informed consent and preoperative investigations were obtained, open reduction and internal fixation was done using a 3.5 mm precontoured superior locking plate with lateral extension under general anesthesia. Postoperative X-rays were done on day 1 and every 6 weeks after operation, until radiological union was achieved. The postoperative pain was assessed using Visual Analogue Scale (VAS) on postoperative days 1, 2 and 10. Postoperatively arm pouch sling was given for 2 weeks followed by active mobilization. Patients were asked to do their daily routine work and avoid lifting heavy weights. The functional outcome was assessed at the end of 2nd and 6th months with the help of Disabilities of the Arm, Shoulder and Hand (DASH) scoring. There were no intraoperative complications in the procedure. The mean VAS score on postoperative day 1 was found to be 5 which decreased to 3 on day 2 and 0 on day 10. The mean DASH score was calculated as 11.63 at the end of postoperative month 2 and then 4.6 at the end of month 6. There was one case of malunion in whom the overhead abduction was restricted but was not painful and was managed conservatively. The precontoured locking plates with lateral extension may be a good method to fix the fractures of the lateral end clavicle, which provide a stable fixation with good functional outcome with very few instances of stiffness and decreased range of motion of the shoulder with the hook plates and failure of fixation in screw and K-wire fixations. It may well be the answer to the fixation questions of the lateral clavicle fractures, although larger comparative studies between the surgical treatment methods are required to confirm the same. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  2. Evaluation of stability of osteosynthesis with K-wires on an artificial model of tibial malleolus fracture.

    PubMed

    Bumči, Igor; Vlahović, Tomislav; Jurić, Filip; Žganjer, Mirko; Miličić, Gordana; Wolf, Hinko; Antabak, Anko

    2015-11-01

    Paediatric ankle fractures comprise approximately 4% of all paediatric fractures and 30% of all epiphyseal fractures. Integrity of the ankle "mortise", which consists of tibial and fibular malleoli, is significant for stability and function of the ankle joint. Tibial malleolar fractures are classified as SH III or SH IV intra-articular fractures and, in cases where the fragments are displaced, anatomic reposition and fixation is mandatory. Type SH III-IV fractures of the tibial malleolus are usually treated with open reduction and fixation with cannulated screws that are parallel to the physis. Two K-wires are used for temporary stabilisation of fragments during reduction. A third "guide wire" for the screw is then placed parallel with the physis. Considering the rules of mechanics, it is assumed that the two temporary pins with the additional third pin placed parallel to the physis create a strong triangle and thus provide strong fracture fixation. To prove this hypothesis, an experiment was conducted on the artificial models of the lower end of the tibia from the company "Sawbones". Each model had been sawn in a way that imitates the fracture of medial malleoli and then reattached with 1.8mm pins in various combinations. Prepared models were then tested for tensile and pressure forces. The least stable model was that in which the fractured pieces were attached with only two parallel pins. The most stable model comprised three pins, where two crossed pins were inserted in the opposite compact bone and the third pin was inserted through the epiphysis parallel with and below the growth plate. A potential method of choice for fixation of tibial malleolar fractures comprises three K-wires, where two crossed pins are placed in the opposite compact bone and one is parallel with the growth plate. The benefits associated with this method include shorter operating times and avoidance of a second operation for screw removal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Early Weightbearing After Operatively Treated Ankle Fractures: A Biomechanical Analysis.

    PubMed

    Tan, Eric W; Sirisreetreerux, Norachart; Paez, Adrian G; Parks, Brent G; Schon, Lew C; Hasenboehler, Erik A

    2016-06-01

    No consensus exists regarding the timing of weightbearing after surgical fixation of unstable traumatic ankle fractures. We evaluated fracture displacement and timing of displacement with simulated early weightbearing in a cadaveric model. Twenty-four fresh-frozen lower extremities were assigned to Group 1, bimalleolar ankle fracture (n=6); Group 2, trimalleolar ankle fracture with unfixed small posterior malleolar fracture (n=9); or Group 3, trimalleolar ankle fracture with fixed large posterior malleolar fracture (n=9) and tested with axial compressive load at 3 Hz from 0 to 1000 N for 250 000 cycles to simulate 5 weeks of full weightbearing. Displacement was measured by differential variable reluctance transducer. The average motion at all fracture sites in all groups was significantly less than 1 mm (P < .05). Group 1 displacement of the lateral and medial malleolus fracture was 0.1±0.1 mm and 0.4±0.4 mm, respectively. Group 2 displacement of the lateral, medial, and posterior malleolar fracture was 0.6±0.4 mm, 0.5±0.4 mm, and 0.5±0.6 mm, respectively. Group 3 displacement of the lateral, medial, and posterior malleolar fracture was 0.1±0.1 mm, 0.5±0.7 mm, and 0.5±0.4 mm, respectively. The majority of displacement (64.0% to 92.3%) occurred in the first 50 000 cycles. There was no correlation between fracture displacement and bone mineral density. No significant fracture displacement, no hardware failure, and no new fractures occurred in a cadaveric model of early weightbearing in unstable ankle fracture after open reduction and internal fixation. This study supports further investigation of early weightbearing postoperative protocols after fixation of unstable ankle fractures. © The Author(s) 2016.

  4. The conservative treatment of pediatric mandibular fracture with prefabricated surgical splint: a case report.

    PubMed

    Kocabay, Ceyda; Ataç, Mustafa Sancar; Oner, Burak; Güngör, Nadir

    2007-08-01

    The use of rigid fixation in children is controversial and may cause growth retardation along cranial suture lines. Intermaxillary fixation for mandibular fractures should be used cautiously as bony ankylosis in the temporomandibular joint (TMJ) and trismus may develop. The high osteogenic potential of the pediatric mandible allows non-surgical management to be successful in younger patients with conservative approaches. In this case, successful conservative treatment of mandibular fracture of a 3-year-old patient is presented.

  5. [Multiple fractures of the lower extremities (a propos of 50 patients)].

    PubMed

    Touzard, R C; Kudela, I

    1975-04-01

    According to a study of 50 multiple fractures of the lower limbs, the frequency of associated lesions justifies the creation of new multiple injury units, well equipped in which may be found specialists of all branches of surgery. Although internal fixation in one stage as an emergency, is ideal in all fractures, one should in fact be circumspect for the danger of infection should lead one to avoid carrying out internal fixation if this is not absolutely necessary.

  6. Comparing hospital outcomes between open and closed tibia fractures treated with intramedullary fixation.

    PubMed

    Smith, Evan J; Kuang, Xiangyu; Pandarinath, Rajeev

    2017-07-01

    Tibial shaft fractures comprise a large portion of operatively treated long bone fractures, and present with the highest rate of open injuries. Intramedullary fixation has become the standard of care for both open and closed injuries. The rates of short term complications and hospital length of stay for open and closed fractures treated with intramedullary fixation is not fully known. Previous series on tibia fractures were performed at high volume centers, and data were not generalizable, further they did not report on length of stay and the impact of preoperative variables on infections, complications and reoperation. We used a large surgical database to compare these outcomes while adjusting for preoperative risk factors. Data were extracted from the ACS-NSQIP database from 2005 to 2014. Cases were identified based on CPT codes for intramedullary fixation and categorized as closed vs open based on ICD9 code. In addition to demographic and case data, primary analysis examined correlation between open and closed fracture status with infection, complications, reoperation and hospital length of stay. Secondary analysis examined preoperative variables including gender, race, age, BMI, and diabetes effect on outcomes. There were 272 cases identified. There were no significant demographic differences between open and closed tibia fracture cases. Open fracture status did not increase the rate of infection, 30day complications, reoperation, or length of stay. The only preoperative factor that correlated with length of stay was age. There was no correlation between BMI, presence of insulin dependent and nondependent diabetes, and any outcome measure. When considering the complication rates for open and closed tibial shaft fractures treated with intramedullary fixation, there is no difference between 30-day complication rate, length of stay, or return to the operating room. Our reported postoperative infection rates were comparable to previous series, adding validity to our results. The heterogeneity of the hospitals included in ACS-NSQIP database allow our data to be generalizable. These methods may underrepresent the true occurrence of infection as operatively treated tibia infections may present late, requiring late revision. Despite limitations, the data reflect on the current burden of managing these once devastating injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Treatment of high-energy pilon fractures using the ILIZAROV treatment.

    PubMed

    Osman, Walid; Alaya, Zeineb; Kaziz, Hamdi; Hassini, Lassad; Braiki, Meriem; Naouar, Nader; Ben Ayeche, Mohamed Laaziz

    2017-01-01

    The management of high-energy pilon fractures is still controversial. Open reduction and internal fixation are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. The aim of this retrospective study was to analyze the clinical and radiographic outcome of the ILIZAROV technique in patients with high-energy pilon fractures. Thirty cases of distal tibia epiphysis fractures (pilon fractures) were managed from 1999 to 2012. The study group included 5 cases of open fractures. The mean age was 47 years. According to Rüedi and Algower classification; 11 fractures were type II, and 19 type III. All fractures were a consequence of high-energy trauma. Fractures of the lower fibula were present in 28 of the patients. An external Fixator was applied for open fractures. Closed injuries were operated on 3 to 13 days after injury, with an average of 8 days. The mean follow-up was 48 months. All fractures united. The external fixator was removed after a mean of 22 weeks (10 - 28 weeks). Two patients with a type III fracture had a delayed union and were treated with corticotomy and dynamisation of the ILIZAROV fixator. Only one secondary displacement of a type III fracture was noted after two months and was treated by adjuction of 2 olive wires. There were no cases of osteomyelitis or deep infections. Pin-tract infections occurred in ten patients. We had not any case of nervous injury due to introduction of the pins. Using radiological criteria for assessement of reduction of the articular fragments, there was excellent and good restoration of articular structure in 24 cases. The average American Orthopeadic Foot and Ankle Society ankle-hind foot score was excellent in 16, good in 6, fair in 6 and poor in 2. Soft tissue healing occurred without need for plastic surgery in all cases. The movements of the ankle ranged from 0 to 20° of dorsiflexion and 5° to 40° of plantar flexion. Twenty patients had gone back to their preinjury profession. The ILIZAROV technique is a safe and a very effective treatment for severe pilon fractures with minimum complications and good healing results.

  8. Treatment of high-energy pilon fractures using the ILIZAROV treatment

    PubMed Central

    Osman, Walid; Alaya, Zeineb; Kaziz, Hamdi; Hassini, Lassad; Braiki, Meriem; Naouar, Nader; Ben Ayeche, Mohamed Laaziz

    2017-01-01

    The management of high-energy pilon fractures is still controversial. Open reduction and internal fixation are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. The aim of this retrospective study was to analyze the clinical and radiographic outcome of the ILIZAROV technique in patients with high-energy pilon fractures. Thirty cases of distal tibia epiphysis fractures (pilon fractures) were managed from 1999 to 2012. The study group included 5 cases of open fractures. The mean age was 47 years. According to Rüedi and Algower classification; 11 fractures were type II, and 19 type III. All fractures were a consequence of high-energy trauma. Fractures of the lower fibula were present in 28 of the patients. An external Fixator was applied for open fractures. Closed injuries were operated on 3 to 13 days after injury, with an average of 8 days. The mean follow-up was 48 months. All fractures united. The external fixator was removed after a mean of 22 weeks (10 - 28 weeks). Two patients with a type III fracture had a delayed union and were treated with corticotomy and dynamisation of the ILIZAROV fixator. Only one secondary displacement of a type III fracture was noted after two months and was treated by adjuction of 2 olive wires. There were no cases of osteomyelitis or deep infections. Pin-tract infections occurred in ten patients. We had not any case of nervous injury due to introduction of the pins. Using radiological criteria for assessement of reduction of the articular fragments, there was excellent and good restoration of articular structure in 24 cases. The average American Orthopeadic Foot and Ankle Society ankle-hind foot score was excellent in 16, good in 6, fair in 6 and poor in 2. Soft tissue healing occurred without need for plastic surgery in all cases. The movements of the ankle ranged from 0 to 20° of dorsiflexion and 5° to 40° of plantar flexion. Twenty patients had gone back to their preinjury profession. The ILIZAROV technique is a safe and a very effective treatment for severe pilon fractures with minimum complications and good healing results. PMID:28904724

  9. [Management of disk displacement with condylar fracture].

    PubMed

    Yu, Shi-bin; Li, Zu-bing; Yang, Xue-wen; Zhao, Ji-hong; Dong, Yao-jun

    2003-07-01

    To investigate clinical features of disk displacement during the course of condylar fracture and to explore the techniques of disk reposition and suturation. 32 patients (10 females and 22 males) who had disk displacements with condylar fractures were followed up. Reduction and reposition of the dislocated disks simultaneously with fixation of fractures were performed. 7 patients underwent intermaxillary fixation with elastic bands for 1 to 2 weeks. The occlusions were satisfactory in all cases but one for the reason of ramus height loss. No TMJ symptom was found when examined 3 months post operation. Anterior disk displacements were most occurred with high condylar process fractures. Surgical reposition and suturation of disk play an important role for the later TMJ-function.

  10. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate constructs and the unlocked IM nail were significantly less with a 50% saw cut depth. Plate fixation was superior to IM nail fixation in limiting the opening of a simulated midtibial stress fracture, and anterior-posterior placement of the plate was an important variable for this construct. Results from these tests can help guide the selection of fixation hardware for patients requiring surgical treatment for a midtibial stress fracture. © 2016 The Author(s).

  11. Treatment of type II odontoid fracture with a novel technique

    PubMed Central

    Zhu, Ce; Wang, Lei; Liu, Hao; Song, Yueming; Liu, Limin; Li, Tao; Gong, Quan

    2017-01-01

    Abstract Surgical methods for type II odontoid fracture can be classified into 2 main groups: anterior or posterior approach. A more effective way to achieve bone fusion with the lowest possible surgical risk is needed. Therefore, the aim of our study was to describe and evaluate a novel technique, cable-dragged reduction/cantilever beam internal fixation for the treatment of type II odontoid fracture. This was a retrospective study enrolled 34 patients underwent posterior cable-dragged reduction/cantilever-beam internal fixation surgery. Medical records, rates of reduction, the location of the instrumentation and fracture healing during follow-up were analyzed. Once fracture healing was obtained, instrumentation was removed. Neck pain (scored using a visual analog scale [VAS]), neck stiffness, patient satisfaction, and neck disability index (NDI) were recorded before and after removing the instrumentation during follow-up. The mean duration of follow up was 22.8 ± 5.3 months. There was no iatrogenic damage to nerves or blood vessels. Radiographic evaluation showed complete reduction in the 20 patients with fracture displacement and satisfactory fracture healing in all 34 cases. Titanium cable breakage was observed in 4 patients after fracture healing. After removal of instrumentation, significant improvements were seen in neck-pain VAS score, neck stiffness, patient satisfaction, and NDI (all P < .01). Posterior cable-dragged reduction/cantilever-beam internal fixation was an optimal salvage maneuver to conventional surgical methods such as anterior screw fixation and C1–C2 screw-rod system. The operative difficulty and incidence of nerve and vascular injury were reduced. Its major disadvantage is the exposure and screw-setting at C3, which is left intact in traditional surgery, and it is suitable only for patients with intact C1 posterior arches. PMID:29095313

  12. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    PubMed

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  13. Surgical treatment of open pilon fractures.

    PubMed

    Zeng, Xian-tie; Pang, Gui-gen; Ma, Bao-tong; Mei, Xiao-long; Sun, Xiang; Wang, Jia; Jia, Peng

    2011-02-01

    To discuss the methods, timing and clinical outcomes of surgical treatment for open pilon fractures. From April 2003 to July 2008, 28 patients with open pilon fractures were treated. All had type C fractures according to the Arbeitsgemeinschaft für osteosynthesefragen-Association for the Study of Internal Fixation (AO/ASIF) classification. Three operative methods were applied, the methods being determined by the types of fracture, soft tissue damage and time interval after injury. Seven cases were treated by debridement and internal fixation with plate; 19 by limited internal fixation combined with external fixation; and 2 by delayed surgery. The clinical outcomes were evaluated by the Burwell-Charnley score. All cases were followed up for from 6 to 48 months (average 24 months). The Burwell-Charnley score of clinical outcomes: anatomic reduction achieved in 12 cases, functional reduction in 15, and unsatisfactory reduction in 1. The healing time was from 2.5 to 11 months (average 4.7 months). Two cases had delayed union. According to the American Orthopaedic Foot and Ankle Society (AOFAS) scale for the ankle joint, there were excellent results in 8 cases, good in 14, fair in 5 and poor in 1. Complications included four cases of skin superficial sloughing, two of superficial infection, one of deep infection, two of delayed fracture union and ten of post-traumatic arthritis. It is important to perform appropriate surgeries for open pilon fracture according to fracture classification, different damage to skin and tissue and time interval after injury. Thorough debridement, proper use of anti-infective medication, appropriate bone grafting, and postoperative ankle function exercise can reduce the occurrence of complications. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  14. Factors Associated With Narcotic Use After Clavicle Fractures.

    PubMed

    Weinberg, Douglas S; Napora, Joshua K; West, William H; Grimberg, Dominic C; Vallier, Heather A

    2016-09-01

    Clavicle fractures are common in adults. Recent studies have shown that operative treatment of clavicle fractures has benefits in many situations. However, there is controversy about the indications. Data on social outcomes are limited. A total of 434 patients with 436 clavicle fractures treated both operatively and nonoperatively at a level 1 trauma center were identified. Narcotic use was recorded 2, 4, 6, 8, 10, 12, 14, and 16 weeks after injury for both treatment groups. Other descriptive data included age, sex, laterality, hand dominance, rib fractures, smoking, alcohol use, employment, long bone or spine fracture, open clavicle fracture, and mechanism of injury. Logistic regression analysis was performed to determine the independent predictors of narcotic use after clavicle fracture. Open reduction and internal fixation was performed in 105 fractures (24%), and 329 fractures were managed nonoperatively. A total of 154 patients (35%) reported some narcotic use 2 weeks after injury, and 15% were still using narcotics 16 weeks after injury. Narcotic use decreased over time in patients treated with open reduction and internal fixation (10% vs 15% after nonoperative management). Patients treated with open reduction and internal fixation reported reduced narcotic use at 16 weeks (odds ratio [OR], 0.454; P=.070). Concurrent rib fracture (OR, 5.668; P<.001), smoking (OR, 3.095; P=.013), unemployment (OR, 5.429; P<.0005), and long bone or spine fracture (OR, 6.761; P<.001) were predictors of narcotic use. Further studies of the social, economic, and financial outcomes of clavicle fracture and osteosynthesis are warranted. [Orthopedics. 2016; 39(5):e917-e923.]. Copyright 2016, SLACK Incorporated.

  15. Biomechanics of far cortical locking.

    PubMed

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  16. Biomechanics of Far Cortical Locking

    PubMed Central

    Bottlang, Michael; Feist, Florian

    2011-01-01

    The development of FCL was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biological fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have shown to enhance fixation and fracture healing: Flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80–88% to actively promote callus proliferation similar to an external fixator. Load distribution is evenly shared between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by s-shaped flexion of FCL screws has shown to induce symmetric callus formation. In combination, these features of FCL constructs have shown to induce more callus and to yield significantly stronger and more consistent healing compared to standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biological healing response of external fixators. PMID:21248556

  17. Lunate fractures and associated radiocarpal and midcarpal instabilities: a systematic review.

    PubMed

    Shunmugam, Meenalochani; Phadnis, Joideep; Watts, Amy; Bain, Gregory I

    2018-01-01

    The aim of this study was to analyse lunate fractures and any associated osseo-ligamentous injuries. A systematic review identified 34 cases. We identified carpal instabilities at the radiocarpal and midcarpal joints in volar and dorsal directions. Radiocarpal instabilities (10/34) were usually dorsoradial (8/10), with a transverse lunate fracture, best seen on a coronal image. Midcarpal instabilities (24/34) were usually volar (14/18), with a volar lunate shear fracture, best seen on a sagittal image. Instabilities were sub-classified into non-displaced, subluxated and dislocated. Associated fractures of the scaphoid and the radial and ulnar styloid processes were common. Lunate fractures without subluxation or dislocation had good outcomes with cast immobilization or fixation of associated fractures. Lunate fracture-subluxations are unstable injuries that are best managed with fixation of the carpal fractures. Lunate fracture-dislocations are complex injuries, requiring stabilization of the lunate, associated fractures and ligament injuries; complications are common and acute or delayed salvage procedures may be required.

  18. Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation.

    PubMed

    Berkes, M B; Little, M T M; Lazaro, L E; Sculco, P K; Cymerman, R M; Daigl, M; Helfet, D L; Lorich, D G

    2012-11-01

    It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.

  19. A Systematic Review and Meta-Analysis Examining the Differences Between Nonsurgical Management and Percutaneous Fixation of Minimally and Nondisplaced Scaphoid Fractures.

    PubMed

    Alnaeem, Hassan; Aldekhayel, Salah; Kanevsky, Johnathan; Neel, Omar Fouda

    2016-12-01

    The optimal management of undisplaced scaphoid fractures remains controversial. A systematic review was conducted to assess the outcomes of acute, undisplaced scaphoid fractures managed with cast immobilization versus percutaneous or miniopen screw fixation in terms of time to return to work (RTW), time to union, and morbidity. PubMed MEDLINE, Ovid MEDLINE, EMBASE, SCOPUS, and Cochrane electronic databases were searched over the period 1974 to 2015. Key words included "scaphoid fracture," "navicular fracture," "hand," "immobilization," "cast," "conservative," "percutaneous," "screw fixation," "mini open," and "minimally invasive." A 2-step review process was done by 2 independent reviewers (H.A. and J.K.) using the following criteria: (1) acute undisplaced scaphoid fracture, (2) English language, (3) RTW duration objectively reported, (5) age older than 15 years, and (5) studies with more than 10 patients. Patient demographics, duration of immobilization, time to RTW, time to union, and complications were extracted. The methodological quality of each study included was assessed independently. Meta-analysis was performed for comparative trials. Ten studies met the inclusion criteria: 6 comparative studies and 4 case series. Patients were divided into 2 groups: cast immobilization (group 1) and percutaneous fixation (group 2). Average time to RTW was 77 days for group 1 versus 46 days for group 2. Average time to radiographic union was 79 days for group 1 versus 44 days for group 2. There was no significant difference in complication rate between the groups (7% in group 1 vs 14% in group 2). Percutaneous fixation of acute undisplaced scaphoid fractures has union rates comparable with those of nonsurgical cast immobilization but with faster RTW and time to union without a significant difference in complication rate. Therapeutic II. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Use of plate fixation without coracoclavicular ligament augmentation for unstable distal clavicle fractures.

    PubMed

    Shin, Sang-Jin; Ko, Young-Won; Lee, Juyeob; Park, Min-Gyue

    2016-06-01

    The purpose of this study was to evaluate the clinical and radiologic outcomes of unstable distal clavicle fractures treated with anatomic plate fixation without coracoclavicular ligament augmentation and to compare the outcome of Neer type IIA with that of type IIB. Twenty-five patients with unstable distal clavicle fractures who underwent anatomic plate fixation without coracoclavicular ligament augmentation were enrolled prospectively, including 9 patients of Neer type IIA and 16 patients of Neer type IIB. Clinical outcomes were evaluated using Constant and University of California-Los Angeles (UCLA) scores. Coracoclavicular distance was measured on plain radiographs. Bone union was achieved in all patients. Satisfactory clinical and radiologic outcomes were obtained regardless of fracture type. After operation, the mean coracoclavicular distance on the injured side was increased by 10% compared with the uninjured side. However, between the patients who showed an increased coracoclavicular distance >10% (Constant score, 89.4 ± 3.7; UCLA score, 32.6 ± 3) and the patients with increased coracoclavicular distance <10% of the uninjured side (Constant score, 88.7 ± 3.6; UCLA score, 31.9 ± 3), there was no statistically significant difference in clinical outcomes of Constant score (P = .934) and UCLA score (P = .598). In unstable distal clavicle fractures, precontoured anatomic plate fixation without coracoclavicular ligament augmentation showed satisfactory clinical outcomes and high union rates even with a small lateral fragment. Patients who had increased coracoclavicular distance also demonstrated satisfactory shoulder functional outcomes regardless of the fracture type. Therefore, anatomic plate fixation without additional coracoclavicular ligament augmentation can be considered one of the treatment options for unstable distal clavicle fracture. Level IV; Case Series; Treatment Study. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Effects of low-dose microwave on healing of fractures with titanium alloy internal fixation: an experimental study in a rabbit model.

    PubMed

    Ye, Dongmei; Xu, Yiming; Zhang, Han; Fu, Tengfei; Jiang, Lan; Bai, Yuehong

    2013-01-01

    Microwave is a method for improving fracture repair. However, one of the contraindications for microwave treatment listed in the literature is surgically implanted metal plates in the treatment field. The reason is that the reflection of electromagnetic waves and the eddy current stimulated by microwave would increase the temperature of magnetic implants and cause heat damage in tissues. Comparing with traditional medical stainless steel, titanium alloy is a kind of medical implants with low magnetic permeability and electric conductivity. But the effects of microwave treatment on fracture with titanium alloy internal fixation in vivo were not reported. The aim of this article was to evaluate the security and effects of microwave on healing of a fracture with titanium alloy internal fixation. Titanium alloy internal fixation systems were implanted in New Zealand rabbits with a 3.0 mm bone defect in the middle of femur. We applied a 30-day microwave treatment (2,450MHz, 25W, 10 min per day) to the fracture 3 days after operation. Temperature changes of muscle tissues around implants were measured during the irradiation. Normalized radiographic density of the fracture gap was measured on the 10th day and 30th day of the microwave treatment. All of the animals were killed after 10 and 30 days microwave treatment with histologic and histomorphometric examinations performed on the harvested tissues. The temperatures did not increase significantly in animals with titanium alloy implants. The security of microwave treatment was also supported by histology of muscles, nerve and bone around the implants. Radiographic assessment, histologic and histomorphometric examinations revealed significant improvement in the healing bone. Our results suggest that, in the healing of fracture with titanium alloy internal fixation, a low dose of microwave treatment may be a promising method.

  2. Effects of Low-Dose Microwave on Healing of Fractures with Titanium Alloy Internal Fixation: An Experimental Study in a Rabbit Model

    PubMed Central

    Zhang, Han; Fu, Tengfei; Jiang, Lan; Bai, Yuehong

    2013-01-01

    Background Microwave is a method for improving fracture repair. However, one of the contraindications for microwave treatment listed in the literature is surgically implanted metal plates in the treatment field. The reason is that the reflection of electromagnetic waves and the eddy current stimulated by microwave would increase the temperature of magnetic implants and cause heat damage in tissues. Comparing with traditional medical stainless steel, titanium alloy is a kind of medical implants with low magnetic permeability and electric conductivity. But the effects of microwave treatment on fracture with titanium alloy internal fixation in vivo were not reported. The aim of this article was to evaluate the security and effects of microwave on healing of a fracture with titanium alloy internal fixation. Methods Titanium alloy internal fixation systems were implanted in New Zealand rabbits with a 3.0 mm bone defect in the middle of femur. We applied a 30-day microwave treatment (2,450MHz, 25W, 10 min per day) to the fracture 3 days after operation. Temperature changes of muscle tissues around implants were measured during the irradiation. Normalized radiographic density of the fracture gap was measured on the 10th day and 30th day of the microwave treatment. All of the animals were killed after 10 and 30 days microwave treatment with histologic and histomorphometric examinations performed on the harvested tissues. Findings The temperatures did not increase significantly in animals with titanium alloy implants. The security of microwave treatment was also supported by histology of muscles, nerve and bone around the implants. Radiographic assessment, histologic and histomorphometric examinations revealed significant improvement in the healing bone. Conclusion Our results suggest that, in the healing of fracture with titanium alloy internal fixation, a low dose of microwave treatment may be a promising method. PMID:24086626

  3. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial

    PubMed Central

    Achten, Juul; Parsons, Nick R; Rangan, Amar; Griffin, Damian; Tubeuf, Sandy; Lamb, Sarah E

    2014-01-01

    Objectives To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. Design A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. Setting 18 trauma centres in the United Kingdom. Participants 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. Interventions Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. Main outcome measures Primary outcome measure: validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient’s experience of pain and disability to give a score out of 100. Secondary outcomes: disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. Results The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was −1.3, 95% confidence interval −4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. Conclusions Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. Trial registration Current Controlled Trials ISCRTN 31379280. UKCRN 8956. PMID:25096595

  4. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation

    PubMed Central

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-01-01

    Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890

  5. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    PubMed

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  6. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    PubMed

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  7. Fractures of the Talus: State of the Art.

    PubMed

    Vallier, Heather A

    2015-09-01

    Talus fractures occur rarely but are often associated with complications and functional limitations. Urgent reduction of associated dislocations is recommended with open reduction and internal fixation of displaced fractures when adjacent soft tissue injury permits. Delayed definitive fixation may reduce the risks of wound complications and infections. Restoration of articular and axial alignment is necessary to optimize ankle and hindfoot function. Despite this, posttraumatic arthrosis occurs frequently after talar neck and body fractures, especially with comminution of the talar body. Osteonecrosis is reported in up to half of talar neck fractures, although many of these injuries will revascularize without collapse of the talar dome. Initial fracture displacement and presence of open fractures increase the risk of osteonecrosis. Talar process fractures may be subtle and easily missed on plain radiographs. Advanced imaging will provide detail to facilitate treatment planning. Therapeutic Level V. See Instructions for Authors for a complete description of levels of evidence.

  8. Fixation of comminuted midshaft clavicle fractures with bone fragments separated by soft tissue using a novel double ligature technique: A case report.

    PubMed

    Ju, Wei-Na; Wang, Cheng-Xue; Wang, Tie-Jun; Qi, Bao-Chang

    2017-11-01

    Clavicle fractures are common, and mostly occur in the midshaft. Methods for operative treatment of midshaft clavicle fractures are evolving, as they improve clinical outcomes compared with traditional conservative management. However, fixation of comminuted midshaft clavicle fractures with bone fragments separated by soft tissue remains a challenge. Here, we present a case of comminuted midshaft clavicle fracture with a bone fragment separated from the main fracture by soft tissue. Left comminuted midshaft clavicle fracture. We treated this patient with a novel double ligature technique using absorbable suturing. In the past 7 years, we have treated >50 patients with this technique. We have achieved good clinical outcomes with no complications. We recommend widespread use of our novel double ligature technique for treating comminuted midshaft clavicle fractures with bone fragments separated by soft tissue.

  9. Fixation of comminuted midshaft clavicle fractures with bone fragments separated by soft tissue using a novel double ligature technique

    PubMed Central

    Ju, Wei-Na; Wang, Cheng-Xue; Wang, Tie-Jun; Qi, Bao-Chang

    2017-01-01

    Abstract Rationale: Clavicle fractures are common, and mostly occur in the midshaft. Methods for operative treatment of midshaft clavicle fractures are evolving, as they improve clinical outcomes compared with traditional conservative management. However, fixation of comminuted midshaft clavicle fractures with bone fragments separated by soft tissue remains a challenge. Patient concerns: Here, we present a case of comminuted midshaft clavicle fracture with a bone fragment separated from the main fracture by soft tissue. Diagnosis: Left comminuted midshaft clavicle fracture. Interventions: We treated this patient with a novel double ligature technique using absorbable suturing. Outcomes: In the past 7 years, we have treated >50 patients with this technique. We have achieved good clinical outcomes with no complications. Lessons: We recommend widespread use of our novel double ligature technique for treating comminuted midshaft clavicle fractures with bone fragments separated by soft tissue. PMID:29137088

  10. Internal fixation of complex fractures of the tarsal navicular with locking plates. A report of 10 cases.

    PubMed

    Cronier, P; Frin, J-M; Steiger, V; Bigorre, N; Talha, A

    2013-06-01

    Tarsal navicular fractures are rare and treatment of comminuted fractures is especially difficult. Since 2007, the authors have had access to 3D reconstruction from CT scan images and specific locking plates, and they decided to evaluate whether these elements improved management of these severe cases. Between 2007 and 2011, 10 comminuted tarsal navicular fractures were treated in a prospective study. All of the fractures were evaluated by 3D reconstruction from CT scan images, with suppression of the posterior tarsal bones. The surgical approach was chosen according to the type of lesion. Reduction was achieved with a mini-distractor when necessary, and stabilized by AO locking plate fixation (Synthes™). Patient follow-up included a clinical and radiological evaluation (Maryland Foot score, AOFAS score). Eight patients underwent postoperative CT scan. All patients were followed up after a mean 20.5 months. Union was obtained in all patients and arthrodesis was not necessary in any of them. The mean Maryland Foot score was 92.8/100, and the AOFAS score 90.6/100. One patient with an associated comminuted calcaneal fracture had minimal sequella from a compartment syndrome of the foot. The authors did not find any series in the literature that reported evaluating tarsal navicular fractures by 3D reconstruction from CT scan images. The images obtained after suppression of the posterior tarsal bones systematically showed a lateral plantar fragment attached to the plantar calcaneonavicular ligament, which is essential for stability, and which helped determine the reduction technique. Locking plate fixation of these fractures has never been reported. Comminuted fractures of the tarsal navicular were successfully treated with specific imaging techniques in particular 3D reconstructions of CT scan images to choose the surgical approach and the reduction technique. Locking plate fixation of the navicular seems to be a satisfactory solution for the treatment of these particularly difficult fractures. Level IV. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  11. Avascular necrosis of the femoral head after osteosynthesis of femoral neck fracture.

    PubMed

    Min, Byung-Woo; Kim, Sung-Jin

    2011-05-18

    The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. We evaluated the incidence of avascular necrosis of the femoral head with the use of contemporary techniques for femoral neck fracture fixation. We then sought to determine what potential risk factors influenced the development of avascular necrosis.Between 1990 and 2005, one hundred sixty-three intracapsular femoral neck fractures in 163 patients were treated with internal fixation at our level-I trauma center. All patients were monitored until conversion to total hip arthroplasty or for a minimum of 2 years postoperatively. Ten patients (10 hips) died and 7 patients (7 hips) were lost to follow-up. The remaining 146 patients (146 hips) had a mean 5.2 years of follow-up (range, 3 months to 17 years). The incidence of avascular necrosis was 25.3% (37 hips). The average time to diagnosis of avascular necrosis was 18.8 months (range, 3-47 months). Patient sex, age, interval from injury to surgery, and mechanism of injury were statistically not associated with the development of avascular necrosis. The quality of fracture reduction, adequacy of fixation, degree of displacement, and comminution of the posterior cortex were significantly associated. After we controlled for patient and radiographic characteristics, multivariate analyses indicated that the important predictors for avascular necrosis are poor reduction (odds ratio=13.889) and initial displacement of the fracture (odds ratio=4.693). Copyright 2011, SLACK Incorporated.

  12. Treatment outcomes of open pelvic fractures associated with extensive perineal injuries.

    PubMed

    Hasankhani, Ebrahim Ghayem; Omidi-Kashani, Farzad

    2013-12-01

    The main causes of death in patients with open pelviperineal injuries are uncontrollable bleeding and pelvic sepsis. The aim of this study was to evaluate the management outcomes of open pelvic fractures associated with extensive perineal injuries. We retrospectively studied 15 cases with open pelvic fractures associated with extensive perineal injuries (urethral and anal canal laceration) admitted between August 2006 and September 2010. Mechanism of injury, Injury Severity Score, associated injuries, hemodynamic status on arrival, resuscitation and transfusion requirements, operative techniques, intra- and postoperative complications, length of intensive care unit and hospital stay, and mortality were recorded in a computerised database for further evaluation and analysis. The male to female ratio was 12:3 with an average age of 38.6 years (ranged, 11 to 65 years). The average packed red blood cell units used were 8 units (ranged, 4 to 21 units). All patients were initially transferred to the operating room for colostomy, radical debridement and fixation of the pelvic fracture by an external fixator. One patient had acute renal failure, which improved with medical treatment and 2 patients (13.3%) died, one with type III anteroposterior compression fracture due to hemorrhagic shock and the other due to septicemia. Open pelvic fractures with extensive perineal injuries are associated with high mortality rates. Early diagnosis and appropriate treatment, including reanimation, colostomy, cystostomy, vigorous and repeated irrigation and debridement, and fixation by an external fixator can improve the outcomes and reduce the mortality rate.

  13. Plate fixation versus intramedullary fixation for midshaft clavicle fractures: Meta-analysis of complications and functional outcomes

    PubMed Central

    Xiao, Hao; Gao, Hengbo; Zheng, Tuokang; Zhao, Jianhui

    2016-01-01

    Objective This analysis critically compares publications discussing complications and functional outcomes of plate fixation (PF) versus intramedullary fixation (IF) for midshaft clavicle fractures. Methods Relevant studies published between January 1990 and October 2014, without language restrictions, were identified in database searches of PubMed®, Medline®, Embase and the Chinese National Knowledge Infrastructure (CNKI). Studies that compared postoperative complications and functional outcomes between PF and IF for midshaft clavicle fractures, and provided sufficient data for analysis, were included in this meta-analysis. Results After strict evaluation, 12 studies were included in this meta-analysis. Studies encompassed 462 participants in the PF group and 440 in the IF group. Study participants were followed up for ≥1 year. Outcomes were superior with IF compared with PF in terms of shoulder constant score at 6-month follow-up, fewer symptomatic hardware complications, lower rate of refracture after hardware removal and less hypertrophic scarring. In other aspects, such as functional recovery at 12-months and 24-months, Disability of Arm, Shoulder and Hand (DASH) questionnaire results at 12-month follow-up, shoulder motion range, rates of superficial infection, temporary brachial plexus lesion, nonunion, malunion, delayed union, implant failure and need for major revision, both techniques were similar. Conclusions Findings of this meta-analysis suggest that, in many respects, IF was superior to PF for the management of midshaft clavicle fractures. This finding could aid surgeons in making decisions on the optimum internal fixation pattern for midshaft clavicular fractures. PMID:26880791

  14. The influence of nail blocking conditions in cattle femoral fractures.

    PubMed

    Paolucci, Leopoldo A; Las Casas, Estevam B; Faleiros, Rafael R; Paz, Cahuê F R; Rocha Junior, Sergio S

    2018-05-07

    To investigate the effect of different fixation strategies of the intramedullary interlocking nail (IIN) on the mechanical behavior of a polymeric implant applied for femoral fracture fixation in calves, and to evaluate the performance of a glass fiber-reinforced polymer applied in a bovine femoral fracture reduction system, five Holstein male animals with a mean weight (±SD) of 62.8 ± 20.4 kg and aged 74 ± 15 were used to generate biomechanical parameters for this study. Twelve models of the fractured bovine femur, simulating a simple oblique fracture, were developed for use during the simulations. The models were divided into three groups, with each group of four models being associated with a different fixation strategy. Models were used to simulate the loading conditions corresponding to a calf in the transition (decubitus position to static position) condition. The maximum stresses found in each set (bone/implant) were compared with the reference stresses of each nail material. Maximum implant stresses were found in the screws and at the interface between the screw and the nail. The performance of implants was influenced by the material and fixation strategy, which can be confirmed by the stress values found in the set. The analysis indicated that the composite nail is able to withstand the loading demands in all fixation strategies. The finite element analysis (FEA) demonstrated that all polymeric materials analyzed provided sufficient resistance to withstand the loading forces imposed to the femur when an adequate blocking strategy was applied. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty.

    PubMed

    Baumgartner, Daniel; Nolan, Betsy M; Mathys, Robert; Lorenzetti, Silvio Rene; Stüssi, Edgar

    2011-07-18

    The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome.

  16. Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty

    PubMed Central

    2011-01-01

    Introduction The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. Method A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Results Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. Conclusions A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome. PMID:21762540

  17. PreFix™ external fixator used to treat a floating shoulder injury caused by gunshot wound.

    PubMed

    Vogels, J; Pommier, N; Cursolle, J-C; Belin, C; Tournier, C; Durandeau, A

    2014-10-01

    Open fractures of the shoulder are extremely rare, and their treatment is a major challenge for surgeons. Only cases encountered in military settings have been reported thus far. Such fractures are often the result of ballistic trauma, which causes extensive damage to both bony and soft tissues. Since these injuries are associated with a high risk of infection and the presence of comminuted fractures, external fixation is necessary for repair. Use of external fixators and revascularization techniques has reduced the number of cases requiring shoulder amputation or disarticulation. Injury to the proximal extremity of the humerus, acromion, and clavicle further complicates the treatment. No published studies have described the assembly of external fixators for fractures in the scapular region with significant bone loss. In addition, no cases have been described in civilian settings. However, with an increase in urban violence and the traffic of illegal arms, civilian surgeons are now encountering an increasing number of patients with these injuries. In this report, we not only present a rare case of floating shoulder injury in a civilian setting but also provide an overview of the existing treatment strategies for this type of trauma, with special focus on the use of external fixators in elective shoulder arthrodesis and on military cases. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. [Case-control study on transverse carpal ligament resection for the prevention of delayed carpal tunnel syndrome after distal radius fracture].

    PubMed

    Wang, Yan-jie; Wang, Shi-gang; Miao, Shu-juan; Su, Xia

    2011-06-01

    To investigate the effects of open reduction by palm side for the distal radius fracture and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection for the prevention of delayed carpal tunnel syndrome after operation. From March 2000 to March 2007, 32 patients (8 males and 24 females, ranging in age from 46 to 66 years) with distal radius fracture were treated with open reduction by palm side and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection; while 30 patients (7 males and 23 females,ranging in age from 45 to 65 years) only with open reduction by palm side and T shape plate internal fixation. The incidences of delayed carpal tunnel syndrome between the two groups were compared. Among 32 patients treated with open reduction by palm side and T shape plate internal fixation with anterior transverse carpal ligament resection, 3 patients had delayed carpal tunnel syndrome; while in 30 patients treated with open reduction by palm side and T shape plate internal fixation, 10 patients had delayed carpal tunnel syndrome. There was significant statistically difference (P < 0.05%). Simultaneous anterior transverse carpal ligament resection can effectively prevent the delayed carpal tunnel syndrome occurrence for the distal radius fracture with open reduction by palm side.

  19. [The use of titanium nickelide devices in treating fractures of the zygomatico-orbital complex].

    PubMed

    Medvedev, Iu A; Sivolapov, K A

    1993-01-01

    The authors analyze the results of surgical treatment of 78 patients with zygomatico-orbital injuries. Mini-cramps and mini-plates of titanium nickelide with thermomechanical memory were employed for fracture fixation. Surgical strategy based on osteosynthesis with the use of such devices provides a reliable fixation of bone fragments and makes the operation less traumatic.

  20. Strength of titanium intramedullary implant versus miniplate fixation of mandibular condyle fractures.

    PubMed

    Frake, Paul C; Howell, Rebecca J; Joshi, Arjun S

    2012-07-01

    To test the strength of internal fixation of mandibular condyle fractures repaired with titanium miniplates versus titanium intramedullary implants. Prospective laboratory experimentation in urethane mandible models and human cadaveric mandibles. Materials testing laboratory at an academic medical center. Osteotomies of the mandibular condyle were created in 40 urethane hemimandible models and 24 human cadaveric specimens. Half of the samples in each group were repaired with traditional miniplates, and the other half were repaired with intramedullary titanium implants. Anteroposterior and mediolateral loads were applied to the samples, and the displacement was measured with reference to the applied force. Titanium intramedullary implants demonstrated statistically significant improved strength and stiffness versus miniplates in the urethane model experimental groups. Despite frequent plastic deformation and mechanical failures of the miniplates, a 1.6-mm-diameter titanium intramedullary pin did not mechanically fail in any of the cases. Intramedullary implantation failures were due to secondary fracture of the adjacent cortical bone or experimental design limitations including rotation of the smooth pin implant. Mechanical implant failures that were encountered with miniplate fixation were not seen with titanium intramedullary implants. These intramedullary implants provide stronger and more rigid fixation of mandibular condyle fractures than miniplates in this in vitro model.

  1. Coupled external fixator and skin flap transposition for treatment of exposed and nonunion bone.

    PubMed

    Zhao, Yong-gang; Ding, Jing; Wang, Neng

    2011-02-01

    To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones. The data of 12 cases of infected nonunion and exposed bone following open fracture treated in our hospital during the period of March 1998 to June 2008 were analysed. There were 10 male patients, 2 female patients, whose age were between 19-52 years and averaged 28 years. There were 10 tibial fractures and 2 femoral fractures. The course of diseases lasted for 12-39 months with the mean period of 19 months. All the cases were treated by the coupled external fixator and skin flap transposition. Primary healing were achieved in 10 cases and delayed healing in 2 cases in whom the tibia was exposed due to soft tissue defect and hence local flap transposition was performed. All the 12 cases had bony union within 6-12 months after operation with the average time of 8 months. They were followed up for 1-3 years and all fractures healed up with good function and no infection recurrence. The coupled external fixator and skin flap transposition therapy have shown optimal effects on treating infected, exposed and nonunion bones.

  2. A preliminary study of bending stiffness alteration in shape changing nitinol plates for fracture fixation.

    PubMed

    Olender, Gavin; Pfeifer, Ronny; Müller, Christian W; Gösling, Thomas; Barcikowski, Stephan; Hurschler, Christof

    2011-05-01

    Nitinol is a promising biomaterial based on its remarkable shape changing capacity, biocompatibility, and resilient mechanical properties. Until now, very limited applications have been tested for the use of Nitinol plates for fracture fixation in orthopaedics. Newly designed fracture-fixation plates are tested by four-point bending to examine a change in equivalent bending stiffness before and after shape transformation. The goal of stiffness alterable bone plates is to optimize the healing process during osteosynthesis in situ that is customized in time of onset, percent change as well as being performed non-invasively for the patient. The equivalent bending stiffness in plates of varying thicknesses changed before and after shape transformation in the range of 24-73% (p values <0.05 for all tests). Tests on a Nitinol plate of 3.0 mm increased in stiffness from 0.81 to 0.98 Nm² (corresponding standard deviation 0.08 and 0.05) and shared a good correlation to results from numerical calculation. The stiffness of the tested fracture-fixation plates can be altered in a consistent matter that would be predicted by determining the change of the cross-sectional area moment of inertia.

  3. An integer programming model for distal humerus fracture fixation planning.

    PubMed

    Maratt, Joseph D; Peaks, Ya-Sin A; Doro, Lisa Case; Karunakar, Madhav A; Hughes, Richard E

    2008-05-01

    To demonstrate the feasibility of an integer programming model to assist in pre-operative planning for open reduction and internal fixation of a distal humerus fracture. We describe an integer programming model based on the objective of maximizing the reward for screws placed while satisfying the requirements for sound internal fixation. The model maximizes the number of bicortical screws placed while avoiding screw collision and favoring screws of greater length that cross multiple fracture planes. The model was tested on three types of total articular fractures of the distal humerus. Solutions were generated using 5, 9, 21 and 33 possible screw orientations per hole. Solutions generated using 33 possible screw orientations per hole and five screw lengths resulted in the most clinically relevant fixation plan and required the calculation of 1,191,975 pairs of screws that resulted in collision. At this level of complexity, the pre-processor took 104 seconds to generate the constraints for the solver, and a solution was generated in under one minute in all three cases. Despite the large size of this problem, it can be solved in a reasonable amount of time, making use of the model practical in pre-surgical planning.

  4. Acute Pelvic Fractures: II. Principles of Management.

    PubMed

    Tile

    1996-05-01

    The past two decades have seen many advances in pelvic-trauma surgery. Provisional fixation of unstable pelvic-ring disruptions and open-book fractures with a pelvic clamp or an external frame with a supracondylar pin has proved markedly beneficial in the resuscitative phase of management. In the completely unstable pelvis, external clamps and frames can act only as provisional fixation and should be combined with skeletal traction. The traction pin is usually used only until a definitive form of stabilization can be applied to keep the pelvic ring in a reduced position. If the patient is too ill to allow operative intervention, the traction pin can remain in place with the external frame as definitive treatment. Symphyseal disruptions and medial ramus fractures should be plated at the time of laparotomy. Lateral ramus fractures can usually be controlled with external frames. A role has been suggested for percutaneous retrograde fixation of the superior pubic ramus; however, the benefits to be gained may not be enough to outweigh the serious risks of penetrating the hip, and this technique should therefore be used only by surgeons trained in its performance. The techniques for posterior fixation are becoming more standardized, but all still carry significant risks, especially to neurologic structures.

  5. [Distal clavicle fractures. Classifications and management].

    PubMed

    Ockert, Ben; Wiedemann, E; Haasters, F

    2015-05-01

    Fractures of the distal third of the clavicle represent 10-30% of all clavicle fractures . Frequently, these fractures result in instability due to a combination of bony and ligamentous injury. Thus, assessment of the stability is essential for adequate treatment of these fractures. This article presents a review of the different classification systems for distal clavicle fractures with respect to anatomical and functional factors to allow for comprehensive assessment of stability. Furthermore, the different treatment options for each fracture type are analyzed. Fractures to the distal third of the clavicle without instability can be treated conservatively with satisfactory outcome. In contrast, instability may result in symptomatic non-union under conservative treatment; therefore, distal clavicle fractures with instability should be treated operatively with respect to the functional demands of the patient. Operative treatment with locked plating in combination with coracoclavicular fixation results in excellent functional results. Arthroscopically assisted fracture fixation may be beneficial in terms of a minimally invasive approach as well as assessment and treatment of associated glenohumeral lesions.

  6. Comparison of titanium and biodegradable miniplates for fixation of mandibular fractures.

    PubMed

    Lee, Hyo-Bin; Oh, Ji-Su; Kim, Su-Gwan; Kim, Hak-Kyun; Moon, Seong-Yong; Kim, Young-Kyun; Yun, Pil-Young; Son, Jun-Sik

    2010-09-01

    The purpose of the present study was to compare the use of biodegradable miniplates and titanium miniplates for the fixation of mandibular fractures. BioSorb FX biodegradable plates and screws and titanium miniplates were used in 91 patients (65 males and 26 females; age range 11 to 69 years) for the treatment of mandibular fractures. The clinical and radiographic findings were recorded at 1, 3, 6, and 12 months after surgery. The overall complication rate was 4.41%. In the biodegradable plate group, infection occurred in 2 cases (4.26%) and was resolved by incision and drainage and antibiotics. In the titanium plate group, infection occurred in 1 case and plate fracture in 1 case (4.56%). The fractured plate was removed, and a new titanium miniplate was applied using a trocar. The infection was resolved with antibiotics. No adverse tissue reactions, malocclusions, or malunions occurred during the observation period. Our results have shown that the rate of morbidity is very low with the use of biodegradable plates and titanium plates, suggesting that biodegradable and titanium plates have the potential for successful use in the fixation of mandibular fractures. Crown Copyright 2010. Published by Elsevier Inc. All rights reserved.

  7. Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study.

    PubMed

    Mansuri, Samir; Abdulkhayum, Abdul Mujeeb; Gazal, Giath; Hussain, Mohammed Abid Zahir

    2013-12-01

    Surgical treatment of fracture mandible using an internal fixation has changed in the last decades to achieve the required rigidity, stability and immediate restoration of function. The aim of the study was to do a Prospective study of 10 patients to determine the efficacy of rectangular grid compression miniplates in mandibular fractures. This study was carried out using 2.0 rectangular grid compression miniplates and 8 mm multidirectional screws as a rigid internal fixation in 10 patients without post operative intermaxillary fixation (IMF). Follow up was done for period of 6 months. All fractures were healed with an absolute stability in post operative period. None of the patient complained of post operative difficulty in occlusion. Within the limits of this study, it can be concluded that rectangular grid compression miniplates was rigid, reliable and thus can be recommended for the treatment of mandibular angle fractures. How to cite this article: Mansuri S, Abdulkhayum AM, Gazal G, Hussain MA. Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study. J Int Oral Health 2013;5(6):93-100 .

  8. Management of displaced comminuted patellar fracture with titanium cable cerclage.

    PubMed

    Yang, Li; Yueping, Ouyang; Wen, Yuan

    2010-08-01

    Management of a displaced comminuted patellar fracture is challenging. Tension band wiring and lag screw fixation are not suitable for such a fracture pattern. Stainless steel wiring with various configurations has been the mainstay of treatment. However, issues of loss of fixation and breakage of wire have not been resolved yet. Partial or total patellectomy is the last resort with a detrimental effect on quadriceps power. Braided titanium cable is stronger in tensile strength and better in fatigue resistance than the stainless steel monofilament wire, and the tension of fixation could be controlled by a graded instrument in its application. We used titanium cable to treat 21 consecutive patients with displaced comminuted patellar fracture. Patients were followed up for a mean period of 24 months (12 to 32 months). The mean score at the final follow-up was 27 points (25 to 30) using the Böstman method. There was no complication except breakage of one cable at the sixth week after the operation and the fracture had united despite the breakage. This technique is simple and effective for these difficult fractures and avoided prolonged immobilisation of the knee. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Rib fixation for severe chest deformity due to multiple rib fractures.

    PubMed

    Igai, Hitoshi; Kamiyoshihara, Mitsuhiro; Nagashima, Toshiteru; Ohtaki, Yoichi

    2012-01-01

    The operative indications for rib fracture repair have been a matter of debate. However, several reports have suggested that flail chest, pain on respiration, and chest deformity/defect are potential conditions for rib fracture repair. We describe our experience of rib fixation in a patient with severe chest deformity due to multiple rib fractures. A 70-year-old woman was admitted with right-sided multiple rib fractures (2nd to 7th) and marked chest wall deformity without flailing caused by an automobile accident. Collapse of the chest wall was observed along the middle anterior axillary line. At 11 days after the injury, surgery was performed to repair the chest deformity, as it was considered to pose a risk of restrictive impairment of pulmonary function or chronic intercostal pain in the future. Operative findings revealed marked displacement of the superior 4 ribs, from the 2nd to the 5th, and collapse of the osseous chest wall towards the thoracic cavity. After exposure of the fracture regions, ribs fixations were performed using rib staplers. The total operation time was 90 minutes, and the collapsed portion of the chest wall along the middle anterior axillary line was reconstructed successfully.

  10. Safe intramedullary fixation of displaced midshaft clavicle fractures with 2.5mm Kirschner wires - technique description and a two-part versus multifragmentary fracture fixation outcome comparison.

    PubMed

    Bakota, Bore; Chan, Gareth; Staresinic, Mario; Rajput, Vishal; Phadnis, Joideep; Korac, Zelimir

    2017-11-01

    The aim of this study was to present a modified Murray and Schwarz 2.5-mm Kirschner wire (K-wire) intramedullary (IM) technique for fixation of displaced midshaft clavicle fractures (DMCF), and to compare the differences in treatment outcome of two-part (Robinson 2B.1) and multifragmentary (Robinson 2B.2) DMCF. A retrospective analysis of 91 patients who underwent IM fixation with a 2.5-mm K-wire for DMCF and had a 1-year post-operative follow-up between 2000 and 2012 was performed. The patients were allocated into two groups: Robinson 2B.1 (n = 64) and Robinson 2B.2 (n = 27). Assessed outcomes were non-union, reoperation rate, wire migration and infection. There was no statistically significant difference in the rate of non-union (2B.1,2B.2; 3.13%, 7.41%; p = 0.365), reoperation (2B.1, 2B.2; 3.13%, 7.41%; p = 0.365), K-wire migration (2B.1, 2B.2; 0.00%, 0.00%; p = 1.00) and clavicle shortening at 12-months (2B.1, 2B.2; 3.13%, 7.41%; p = 0.365). Intramedullary clavicle fixation with a 2.5-mm K-wire is a safe surgical technique. 2B.1 injuries treated with 2.5-mm IM K-wire fixation have relatively improved outcome compared with displaced 2B.2 fractures for both non-union and reoperation rates. There were no occurrences of implant migration with either 2B.1 or 2B.2 injuries, and a non-significant difference in implant irritation was documented with IM K-fixation. The non-union rate with K-wire IM fixation of 2B.1 injuries concords with the published results of other IM devices and thus this technique should be added to the surgeon's armamentarium when considering surgical treatment of such injuries. © 2017 Elsevier Ltd. All rights reserved.

  11. Modified Labial Button Technique for Maintaining Occlusion After Caudal Mandibular Fracture/Temporomandibular Joint Luxation in the Cat.

    PubMed

    Goodman, Alice E; Carmichael, Daniel T

    2016-03-01

    Maxillofacial trauma in cats often results in mandibular symphyseal separation in addition to injuries of the caudal mandible and/or temporomandibular joint (TMJ). Caudal mandibular and TMJ injuries are difficult to access and stabilize using direct fixation techniques, thus indirect fixation is commonly employed. The immediate goals of fixation include stabilization for return to normal occlusion and function with the long-term objective of bony union. Indirect fixation techniques commonly used for stabilization of caudal mandibular and temporomandibular joint fracture/luxation include maxillomandibular fixation (MMF) with acrylic composite, interarcade wiring, tape muzzles, and the bignathic encircling and retaining device (BEARD) technique. This article introduces a modification of the previously described "labial reverse suture through buttons" technique used by Koestlin et al and the "labial locking with buttons" technique by Rocha et al. In cases with minimally displaced subcondylar and pericondylar fractures without joint involvement, the labial button technique can provide sufficient stabilization for healing. Advantages of the modified labial button technique include ease of application, noninvasive nature, and use of readily available materials. The construct can remain in place for a variable of amount of time, depending on its intended purpose. It serves as an alternative to the tape muzzle, which is rarely tolerated by cats. This technique can be easily used in conjunction with other maxillomandibular repairs, such as cerclage wire fixation of mandibular symphyseal separation. The purpose of this article is to demonstrate a modified labial button technique for maintaining occlusion of feline caudal mandibular fractures/TMJ luxations in a step-by-step fashion.

  12. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    PubMed

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  13. Nature and results of treatment of war wounds caused by cluster bombs.

    PubMed

    Mitković, Milorad; Bumbasirević, Marko; Grubor, Predrag; Milenković, Sasa; Micić, Ivan; Stojiljković, Predrag; Kostić, Igor; Karaleić, Sasa; Stamenić, Sonja; Pavlović, Predrag; Stanojlović, Milos; Jovanović, Vladimir; Radovanović, Zoran; Cirić, Tamara; Kutlesić-Stojanović, Katarina; Mitković, Milan

    2013-01-01

    The aim of this study is to describe the nature of war wounds with fracture caused by cluster bombs and to suggest treatment options for such injuries. The nature of wounds caused by cluster bombs differs from those caused by conventional arms (they are more severe). The sides of the wounds are represented by conquasated soft tissues (such as fat and muscle) with thick dead tissues, ordinarily with a thickness of 0.5-4.5 cm. Another main characteristic of such injuries is the high percentage of amputations needed due to the high rate of neurovascular damage. This paper investigates the cases of 81 patients who sustained a total of 99 war wounds with fractures. The average age of the patients was 32.7 years while the youngest was 20 and the oldest, 77. According to The International Committee of the Red Cross (ICRC) classification of war wounds, 14 patients had grade I injuries, 48 patients grade II, and 29 patients, grade III. Mitkovic external fixation system, known also as the "War Fixator" was used for all fractures fixation. One protocol, which was a modification of the ICRC's protocol adapted to our specific conditions, was used throughout the study. For solving soft tissue defects, a rotator fasciocutan flap was the most frequently used. For solving of bones defect Mitkovic reconstructive external fixation device was used. All fractures we treated healed. We concluded that shortening the procedural time and being a very simple, immediate using of Mitkovic versatile external fixator ("War Fixator") is, leads to desirable results.

  14. Comparison of arthroscopic reduction and percutaneous fixation and open reduction and internal fixation for tibial plateau fractures.

    PubMed

    Sun, Yufu; Sun, Kai; Jiang, Wenxue

    2018-06-01

    To conduct a meta-analysis with randomized controlled trials (RCTs) published in full text to demonstrate database to show the associations of perioperative, postoperative outcomes of arthroscopic reduction and percutaneous fixation(ARPF) and open reduction and internal fixation(ORIF) for tibial plateau fractures to provide the predictive diagnosis for clinic. Literature search was performed in PubMed, Embase, Web of Science and Cochrane Library for information from the earliest date of data collection to June 2017. RCTs comparing the benefits and risks of ARPF with those of ORIF in tibial plateau fractures were included. Statistical heterogeneity was quantitatively evaluated by X 2 test with the significance set P < 0.10 or I 2  > 50%. Seven RCTs consisting of 571 patients were included.(288 ARPF patients; 283 ORIF patients;). Pooled results showed that ORIF was related to a greater increase in operative time, incision length, hospital stay, perioperative complications, and full weight bearing compared with ARPF. The results showed that ARPF was related to a greater increase in ROM Rasmussen Scores compared with ORIF (WMD = 10.38; 95% CI, 8.31, 12.45; P < 0.10). This meta-analysis showed that arthroscopic reduction and percutaneous fixation for tibial plateau fractures, compared with open reduction and internal fixation, could demonstrate an decreased risk of perioperative and postoperative complications and improve clinical outcome in operative time, incision length, hospital stay, perioperative complications, full weight bearing and Rasmussen Scores. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Treatment of transverse patellar fractures: a comparison between metallic and non-metallic implants.

    PubMed

    Heusinkveld, Maarten H G; den Hamer, Anniek; Traa, Willeke A; Oomen, Pim J A; Maffulli, Nicola

    2013-01-01

    Several methods of transverse patellar fixation have been described. This study compares the clinical outcome and the occurrence of complications of various fixation methods. The databases PubMed, Web of Science, Science Direct, Google Scholar and Google were searched. A direct comparison between fixation techniques using mixed or non-metallic implants and metallic K-wire and tension band fixation shows no significant difference in clinical outcome between both groups. Additionally, studies reporting novel operation techniques show good clinical results. Studies describing the treatment of patients using non-metallic or mixed implants are fewer compared with those using metallic fixation. A large variety of clinical scoring systems were used for assessing the results of treatment, which makes direct comparison difficult. More data of fracture treatment using non-metallic or mixed implants is needed to achieve a more balanced comparison.

  16. Open reduction and internal fixation of intra-articular fractures of the mandibular condyle: our first experiences.

    PubMed

    Vesnaver, Ales

    2008-10-01

    Treatment of intra-articular fractures of the mandibular condyle head is conservative at most institutions dealing with facial fractures. Recently, reports had been published about benefits of surgical treatment in these fractures. From July 2004 until the end of June 2006, 13 patients with 16 displaced intra-articular fractures of the mandibular condyle were treated with open reduction and internal fixation at the Department of Oral and Maxillofacial Surgery in Ljubljana, Slovenia, using the preauricular approach and the lag screw technique. Twelve of the 13 patients could open their mouths for 40 mm or more, and 10 had a deflection of the chin of less than 2 mm upon maximal opening. None of the patients experienced pain upon rest, palpation, or chewing. Occlusion was not noted as altered in any of the cases, neither subjectively, nor on examination. There were no cases of postoperative weakness of the temporal branch of the facial nerve. Surgical treatment of intra-articular condyle fractures using the preauricular approach achieves a good exposure and enables proper reduction. Stable fixation of fractured bony fragments can be achieved using the lag screw technique. Another benefit of open exposure is revision and repair of TMJ soft tissues. With the appropriate surgical technique, the surgical procedure is safe and leads to good results.

  17. Modified rush pin technique for two- or three-part proximal humeral fractures.

    PubMed

    Mallick, A; Hearth, M; Singh, S; Pandey, R

    2008-12-01

    To report the outcomes of modified Rush pin fixation for proximal humeral fractures. 42 men and 20 women aged 19 to 94 (mean, 64) years with 2- or 3-part proximal humeral fractures underwent reduction and fixation using the modified Rush pin technique. 11 patients died from reasons unrelated to the surgery. Of 40 (out of 51) patients completing a subjective functional assessment using an Oxford Shoulder Questionnaire, 28 (70%) had 2-part and 10 (25%) had 3-part displaced fractures, and the remaining 2 (5%) had fracture-dislocations (one being 2-part and one 3-part). 25 (63%) patients were very satisfied (including one with a 3-part fracture after 6 months of rehabilitation), 7 (17%) were moderately satisfied, and 8 (20%) were not satisfied. There were 8 complications, including pin cut-out from the proximal fragment (n=2), proximal pin migration (n=2), distal pin migration (n=1), cortical perforation during surgery (n=1), mild ulnar nerve symptoms (n=1). No patients had non-union, myositis ossificans, avascular necrosis of the humeral head, or axillary nerve injury. The modified Rush pin fixation minimises tissue dissection; the implants are cheap and readily available; and the technical expertise is easily learnt. This technique is a suitable alternative of fixing proximal humeral fractures, especially in the elderly.

  18. Bone Marrow Stem Cells Added to a Hydroxyapatite Scaffold Result in Better Outcomes after Surgical Treatment of Intertrochanteric Hip Fractures

    PubMed Central

    Gutierres, Manuel; Lopes, M. Ascenção; Santos, J. Domingos; Cabral, A. T.; Pinto, R.

    2014-01-01

    Introduction. Intertrochanteric hip fractures occur in the proximal femur. They are very common in the elderly and are responsible for high rates of morbidity and mortality. The authors hypothesized that adding an autologous bone marrow stem cells concentrate (ABMC) to a hydroxyapatite scaffold and placing it in the fracture site would improve the outcome after surgical fixation of intertrochanteric hip fractures. Material and Methods. 30 patients were randomly selected and divided into 2 groups of 15 patients, to receive either the scaffold enriched with the ABMC (Group A) during the surgical procedure, or fracture fixation alone (Group B). Results. There was a statistically significant difference in favor of group A at days 30, 60, and 90 for Harris Hip Scores (HHS), at days 30 and 60 for VAS pain scales, for bedridden period and time taken to start partial and total weight bearing (P < 0.05). Discussion. These results show a significant benefit of adding a bone marrow enriched scaffold to surgical fixation in intertrochanteric hip fractures, which can significantly reduce the associated morbidity and mortality rates. Conclusion. Bone marrow stem cells added to a hydroxyapatite scaffold result in better outcomes after surgical treatment of intertrochanteric hip fractures. PMID:24955356

  19. The chopstick-noodle twist: an easy technique of percutaneous patellar fixation in minimally displaced patellar fractures.

    PubMed

    Muzaffar, Nasir; Ahmad, Nawaz; Ahmad, Aejaz; Ahmad, Nissar

    2012-01-01

    We report six cases of minimally displaced two-part patellar fractures with skin injury over the patella that were treated with percutaneous K wire fixation and compression applied using stainless steel (SS) wire. This technique makes it possible to perform early operative treatment in cases where unhealthy skin is not amenable to conventional tension band wiring. The technique employs two K wires inserted through the two fracture fragments under local or regional anaesthesia. They are then compressed using simple SS wire knots at the two ends - making it look like noodles at the end of two chopsticks. The fixation is subsequently augmented with a cylindrical plaster-of-Paris cast. The technique is simple, cheap and does not cause soft tissue injury.

  20. Technique for repair of fractures and separations involving the cartilaginous portions of the anterior chest wall.

    PubMed

    Bonne, Stephanie L; Turnbull, Isaiah R; Southard, Robert E

    2015-06-01

    Internal fixation of the ribs has been shown in numerous studies to decrease complications following traumatic rib fractures. Anterior injuries to the chest wall causing cartilaginous fractures, although rare, can cause significant disability and can lead to a variety of complications and, therefore, pose a unique clinical problem. Here, we report the surgical technique used for four patients with internal fixation of injuries to the cartilaginous portions of the chest wall treated at our center. All patients had excellent clinical outcomes and reported improvement in symptoms, with no associated complications. Patients who have injuries to the anterior portions of the chest wall should be considered for internal fixation of the chest wall when the injuries are severe and can lead to clinical disability.

  1. Local strategies to prevent and treat osteoporosis.

    PubMed

    Torstrick, F Brennan; Guldberg, Robert E

    2014-03-01

    Despite advances in systemic osteoporosis therapeutic outcomes, management of fragility fractures and implant fixation in osteoporotic bone remain difficult clinical challenges. Low initial bone density and a prolonged healing response can lead to fracture nonunion and aseptic implant loosening. Local treatment strategies could be used to prevent fracture, accelerate healing, and increase implant fixation by locally stimulating anabolic pathways or inhibiting catabolic pathways. Local strategies under investigation include direct drug release from injectable materials or implant surface coatings. Common locally delivered drugs include bisphosphonates, parathyroid hormone, and bone morphogenetic proteins, yet additional compounds targeting novel pathways in bone biology are also being actively explored. Mechanical stimulation via low intensity pulsed ultrasound, alone or in combination with drug therapy, may also prove effective to promote local bone healing and implant fixation within osteoporotic bone.

  2. Use of Orthodontic Mini-Implants for Maxillomandibular Fixation in Mandibular Fracture

    PubMed Central

    Pires, Mario Sergio Medeiros; Reinhardt, Leandro Calcagno; Antonello, Guilherme de Marco; Torres do Couto, Ricardo

    2011-01-01

    Orthodontic appliances for skeletal anchorage are becoming increasingly more common in clinical practice. Similarly, different terms such as mini-implants, microimplants, and miniscrews have been used. There is a wide array of appliances currently on the market, in different designs and sizes, diameters, degree of titanium purity, and surface treatment. These appliances have been used for a variety of indications, including tooth retraction, intrusion, and traction. This study aimed to report the clinical case of a 19-year-old patient with a fractured mandible and to propose a novel use of mini-implants: the perioperative placement of mini-implants as anchors for maxillomandibular fixation steel wire ligatures. We concluded that this appliance provides an effective maxillomandibular fixation in patients with mandibular fracture, with little increase in the cost of surgery. PMID:23205173

  3. Patellar Shape-Memory Fixator for the Treatment of Comminuted Fractures of the Inferior Pole of the Patella

    NASA Astrophysics Data System (ADS)

    Liu, Xin-Wei; Shang, Hui-Juan; Xu, Shuo-Gui; Wang, Zhi-Wei; Zhang, Chun-Cai; Fu, Qing-Ge

    2011-07-01

    Comminuted and displaced fractures of the inferior pole of the patella are not easy to reduce and it is difficult to fix the fragments soundly enough to allow early movement of the knee. The purpose of this study is to evaluate the clinical effectiveness of the internal fixation technique with Patellar Shape-Memory Fixator (PSMF) in acute comminuted fractures of the inferior pole of the patella. We retrospectively studied 25 patients with comminuted fractures of the inferior pole of the patella who were treated with PSMF and followed up for a mean period of 26 months (14 to 60). All the fractures healed at a mean of 6 weeks (5 to 7). The mean grading at the final follow-up was 29.5 points (27 to 30) using the Bostman score, with no observable restriction of movement. No breakage of the PSMF or infection occurred. No delayed union, nonunion, and infection were seen. This technique preserved the length of the patella, reduced the comminuted fragments of the inferior pole and avoided long-term immobilization of the knee.

  4. [Treatment of acromion base fractures with double plates internal fixation].

    PubMed

    Lü, Guo-Qiang; Zhu, Jun-Kun; Lan, Shu-Hua; Wu, Quan-Zhou; Zheng, Rong-Zong; Zheng, Chong-Wu

    2013-09-01

    To study clinical effects of double plates fixation for the treatment of acromion base fracutres. From January 2010 to May 2012, 7 patients with acromion base fractures were treated with double plates ORIF surgical treatment. There were 5 males and 2 females, with an average age of 36.3 years old (ranged, 24 to 62 years old). All fractures were acuted and closed injuries. The duration from injury to surgery was 4.6 days (ranged, 2 to 10 days). Hardegger functional criterion, Visual Analogue Scale (VAS) and complications of the patients were documented analysis. All the patients were followed up,and the duration ranged from 4 to 13 months (averaged 8.9 months). The healing duration of fractures ranged from 8 to 14 weeks without any infection, shoulder instability, subacromial impingement syndrome, nonunion and failure of internal fixation. At the latest follow-up, the VAS ranged from 0 to 5. According to Hardegger criterion, 2 patients got an excellent result, 4 good and 1 poor. Double plates ORIF plays a positive role in the treatment of acromion base fractures, which reduces complications and maximally restore the function of shoulder.

  5. [The Postero-Lateral Approach--An Alternative to Closed Anterior-Posterior Screw Fixation of a Dislocated Postero-Lateral Fragment of the Distal Tibia in Complex Ankle Fractures].

    PubMed

    von Rüden, C; Hackl, S; Woltmann, A; Friederichs, J; Bühren, V; Hierholzer, C

    2015-06-01

    The dislocated posterolateral fragment of the distal tibia is considered as a key fragment for the successful reduction of comminuted ankle fractures. The reduction of this fragment can either be achieved indirectly by joint reduction using the technique of closed anterior-posterior screw fixation, or directly using the open posterolateral approach followed by plate fixation. The aim of this study was to compare the outcome after stabilization of the dislocated posterolateral tibia fragment using either closed reduction and screw fixation, or open reduction and plate fixation via the posterolateral approach in complex ankle fractures. In a prospective study between 01/2010 and 12/2012, all mono-injured patients with closed ankle fractures and dislocated posterolateral tibia fragments were assessed 12 months after osteosynthesis. Parameters included: size of the posterolateral tibia fragment relative to the tibial joint surface (CT scan, in %) as an indicator of injury severity, unreduced area of tibial joint surface postoperatively, treatment outcome assessed by using the "Ankle Fracture Scoring System" (AFSS), as well as epidemiological data and duration of the initial hospital treatment. In 11 patients (10 female, 1 male; age 51.6 ± 2.6 years [mean ± SEM], size of tibia fragment 42.1 ± 2.5 %) the fragment fixation was performed using a posterolateral approach. Impaired postoperative wound healing occurred in 2 patients of this group. In the comparison group, 12 patients were treated using the technique of closed anterior-posterior screw fixation (10 female, 2 male; age 59.5 ± 6.7 years, size of tibia fragment 45.9 ± 1.5 %). One patient of this group suffered an incomplete lesion of the superficial peroneal nerve. Radiological evaluation of the joint surface using CT scan imaging demonstrated significantly less dislocation of the tibial joint surface following the open posterolateral approach (0.60 ± 0.20 mm) compared to the closed anterior-posterior screw fixation (1.03 ± 0.08 mm; p < 0.05). Assessment of the treatment outcome using the AFSS demonstrated a significantly higher score of 97.4 ± 6.4 in the group with a posterolateral approach compared to a score of 74.4 ± 12.1 (p < 0.05) in the group with an anterior-posterior screw fixation. In comparison to the anterior-posterior screw fixation, open reduction and fixation of the dislocated, posterolateral key fragment of the distal tibia using a posterolateral approach resulted in a more accurate fracture reduction and significantly better functional outcome 12 months after surgery. In addition, no increased rate of postoperative complications, or extended hospital stay was observed but there was less severe post-traumatic joint arthritis. The results of this study suggest that in complex ankle factures the open fixation of the dislocated posterolateral fragment is recommended as an alternative surgical procedure and may be beneficial for both clinical and radiological long-term outcomes. Georg Thieme Verlag KG Stuttgart · New York.

  6. Minimally invasive treatment of pilon fractures with a low profile plate: preliminary results in 17 cases.

    PubMed

    Borens, Olivier; Kloen, Peter; Richmond, Jeffrey; Roederer, Goetz; Levine, David S; Helfet, David L

    2009-05-01

    To determine the results of "biologic fixation" with a minimally invasive plating technique using a newly designed low profile "Scallop" plate in the treatment of pilon fractures. Retrospective case series. A tertiary referral center. Seventeen patients were treated between 1999 and 2001 for a tibial plafond fracture at the Hospital for Special Surgery with a newly designed low-profile plate. Eleven of the fractures (65%) were high-energy injuries. Two fractures were open. Staged surgical treatment with open reduction and fixation of the fibular fracture and application of an external fixator was performed in 12 cases. As soon as the soft tissues and swelling allowed, i.e. skin wrinkling, the articular surface was reconstructed and simply reduced, if necessary through an small incision, and the articular block was fixed to the diaphysis using a medially placed, percutaneously introduced flat scallop plate. In the remaining five cases the operation was performed in one session. Time to healing and complications including delayed union, non-union, instrument failure, loss of fixation, infection, quality of reduction and number of reoperations were evaluated. Quality of results and outcome were graded using the ankle-hindfoot-scale and a modified rating system. All patients went on to bony union at an average time of 14 weeks. There were no plate failures or loss of fixation/reduction. Two superficial wound-healing problems resolved with local wound care. At an average follow up of 17 months (range 6-29 months) eight patients (47%) had an excellent result; seven (41%) had a fair result whereas two (12%) had a poor result. The average ankle-hindfoot-score was 86.1 (range 61-100). Four patients have had the hardware removed and one of them is awaiting an ankle arthrodesis. Based on these initial results, it appears that a minimally invasive surgical technique including new low profile plate can decrease soft tissue problems while leading to fracture healing and obtaining results comparable with other more recent series. We believe that this new "Scallop Plate" is effective for the treatment of pilon fractures and should be used in conjunction with a staged procedure in the acute trauma setting.

  7. Internal fixation of pilon fractures of the distal radius.

    PubMed Central

    Trumble, T. E.; Schmitt, S. R.; Vedder, N. B.

    1993-01-01

    When closed manipulation fails to restore articular congruity in comminuted, displaced fractures of the distal radius, open reduction and internal fixation is required. Results of surgical stabilization and articular reconstruction of these injuries are reviewed in this retrospective study of 49 patients with 52 displaced, intra-articular distal radius fractures. Forty-three patients (87%) with a mean age of 37 years (range of 17 to 79 years) were available for evaluation. The mean follow-up time was 38 months (range 22-69 months). When rated according to the Association for the Study of Internal Fixation (ASIF), 19 were type C2 and 21 were type C3. We devised an Injury Score System based on the initial injury radiographs to classify severely comminuted intra-articular fractures and to identify those associated with carpal injury (3 patients). Post-operative fracture alignment, articular congruity, and radial length were significantly improved following surgery (p < .01). Grip strength averaged 69% +/- 22% of the contralateral side, and the range of motion averaged 75% +/- 18% of the contralateral side post-operatively. A combined outcome rating system that included grip strength, range of motion, and pain relief averaged 76% +/- 19% of the contralateral side. There was a statistically significant decrease in the combined rating with more severe fracture patterns as defined by the ASIF system (p < .01), Malone classification (p < .03), and the Injury Score System (p < .001). The Injury Score System presented here, and in particular the number of fracture fragments, correlated most closely with outcome of all the classification systems studied. Operative treatment of these distal radius fractures with reconstruction of the articular congruity and correction of the articular surface alignment with internal fixation and/or external fixation, can significantly improve the radiographic alignment and functional outcome. Furthermore, the degree to which articular stepoff, gap between fragments, and radial shortening are improved by surgery is strongly correlated with improved outcome, even when the results are corrected for severity of initial injury, whereas correction of radial tilt or dorsal tilt did not correlate with improved outcome. Images Figure 2 PMID:8209554

  8. Should fractures in massive intercalary bone allografts of the lower limb be treated with ORIF or with a new allograft?

    PubMed

    Aponte-Tinao, Luis A; Ayerza, Miguel A; Muscolo, D Luis; Farfalli, Germán L

    2015-03-01

    Massive bone allografts have been used for limb salvage of bone tumor resections as an alternative to endoprostheses, although they have different outcomes and risks. There is no general consensus about when to use these alternatives, but when it is possible to save the native joints after the resection of a long bone tumor, intercalary allografts offer some advantages despite complications, such as fracture. The management and outcomes of this complication deserve more study. The purposes of this study were to (1) analyze the fracture frequency in a group of patients treated with massive intercalary bone allografts of the femur and tibia; (2) compare the results of allografts treated with open reduction and internal fixation (ORIF) with those treated with resection and repeat allograft reconstruction; and (3) determine the likelihood that treatment of a fracture resulted in a healed intercalary reconstruction. We reviewed patients treated with intercalary bone allografts between 1991 and 2011. During this period, patients were generally treated with intercalary allografts when after tumor resection at least 1 cm of residual epiphysis remained to allow fixation of the osteotomy junction. To obtain a homogeneous group of patients, we excluded allograft-prosthesis composites and osteoarticular and hemicylindrical intercalary allografts from this study. We analyzed the fracture rate of 135 patients reconstructed with segmental intercalary bone allografts of the lower extremities (98 femurs and 37 tibias). In patients whose grafts fractured were treated either by internal fixation or a second allograft, ORIF generally was attempted but after early failures in femur fractures, these fractures were treated with a second allograft. Using a chart review, we ascertained the frequency of osseous union, complications, and reoperations after the treatment of fractured intercalary allografts. Followup was at a mean of 101 months (range, 24-260 months); of the original 135 patients, no patient was lost to followup. At latest followup, 19 patients (14%) had an allograft fracture (16 femurs [16%] and three tibias [8%]). Six patients were treated with internal fixation and addition of autologous graft (three femurs and three tibias) and 13 patients were treated with a second intercalary allograft (13 femurs). The three patients with femoral allograft fractures treated with internal fixation and autologous grafts failed and were treated with a second allograft, whereas those patients with tibia allograft fractures treated by the same procedure healed without secondary complications. When we analyzed the 16 patients with a second intercalary allograft (13 as primary treatment of the fracture and three as secondary treatment of the fracture), five failed (31%) and were treated with resection of the allograft and reconstructed with an endoprosthesis (four patients) or an osteoarticular allograft (one patient). Fractures of intercalary allografts of the tibia could successfully be treated with internal fixation and autologous iliac crest bone graft; however, this treatment failed when used for femur allograft fractures. Femoral fractures could be treated with resection and repeat allograft reconstruction, however, with a higher refracture frequency. The addition of a vascularized fibular graft in the second attempt should be considered. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  9. [Safety evaluation of secondary conversion from external fixation to internal fixation for open tibia fractures].

    PubMed

    Liu, Xi; Cen, Shiqiang; Xiang, Zhou; Zhong, Gang; Yi, Min; Fang, Yue; Liu, Lei; Huang, Fuguo

    2017-06-01

    To evaluate the safety of conversion from external fixation to internal fixation for open tibia fractures. Between January 2010 and December 2014, 94 patients (98 limbs) with open tibia fractures were initially treated with external fixators at the first stage, and the clinical data were retrospectively analyzed. In 29 cases (31 limbs), the external fixators were changed to internal fixation for discomfort, pin tract response, Schantz pin loosening, delayed union or non-union after complete wound healing and normal or close to normal levels of erythrocyte sedimentation rate (ESR), C reactive protein (CRP), and the leucocyte count as well as the neutrophil ratio (trial group); in 65 cases (67 limbs), the external fixators were used as the ultimate treatment in the control group. There was no significant difference in gender, age, side of the limbs, interval from injury to the first debridement, initial pathogenic bacteria, the limbs that skin grafting or flap transferring for skin and soft tissue defect between the two groups ( P >0.05). The incidence of Gustilo type III fractures in the control group was significantly higher than that in the trial group ( P =0.000). The overall incidence of infection was calculated respectively in the two groups. The incidence of infection according to different fracture types and whether skin grafting or flap transferring was compared between the two groups. The information of the pathogenic bacteria was recorded in the infected patients, and it was compared with the results of the initial culture. The incidence of infection in the patients of the trial group using different internal fixation instruments was recorded. The overall incidences of infection for the trial and control groups were 9.7% (3/31) and 9.0% (6/67) respectively, showing no significant difference ( χ 2 =0.013, P =0.909). No infection occurred in Gustilo type I and type II patients. The incidence of infection for Gustilo type IIIA patients in the trial group and the control group were 14.3% (1/7) and 6.3% (2/32) respectively, showing no significant difference ( χ 2 =0.509, P =0.476); the incidence of infection for type IIIB patients in the two groups were 50.0% (2/4) and 14.3% (2/14) respectively, showing no significant difference ( χ 2 =2.168, P =0.141); and the incidence of infection for type IIIC patients in the two groups were 0 and 16.7% (2/12) respectively, showing no significant difference ( χ 2 =0.361, P =0.548). Of all the infected limbs, only 1 limb in the trial group had the same Staphylococcus Aureus as the result of the initial culture. In the patients who underwent skin grafting or flap transferring, the incidence of infection in the trial and control groups were 33.3% (2/6) and 13.3% (2/15) respectively, showing no significant difference ( χ 2 =1.059, P =0.303). After conversion to internal fixation, no infection occurred in the cases that fixed with nails (11 limbs), and infection occurred in 4 of 20 limbs that fixed with plates, with an incidence of infection of 20%. Conversion from external fixation to internal fixation for open tibia fractures is safe in most cases. However, for open tibia fractures with extensive and severe soft tissue injury, especially Gustilo type III patients who achieved wound heal after flap transfer or skin grafting, the choice of secondary conversion to internal fixation should carried out cautiously. Careful pre-operative evaluation of soft tissue status, cautious choice of fixation instrument and meticulous intra-operative soft tissue protection are essential for its safety.

  10. Conventional bone plate fixation of distal radius and ulna fractures in toy breed dogs.

    PubMed

    Ramírez, J M; Macías, C

    2016-03-01

    To describe the outcome of bone plate fixation of distal radius and ulna fractures in toy breed dogs treated with conventional bone plates. Records of 15 toy breed dogs with distal radius and ulna fractures were retrospectively reviewed for signalment, method of fixation, complications and clinical and radiographic assessments. A telephone-based owner questionnaire was conducted to determine long-term function and client satisfaction. Age ranged from 4 months to 6 years. Body weight ranged from 1 to 4 kg. Dynamic compression plates were used in 13 dogs and veterinary cuttable plates were used in 2 dogs as the means of fixation. Full radiographic and clinical follow-up data were available for 10 dogs and follow-up was performed between 6 and 8 weeks postoperatively. At that time, all fractures had healed and return to function was considered excellent in all 10 dogs. Five dogs did not return for hospital evaluation because they were judged by their owners to be free of lameness. In two cases, owners could not be contacted by telephone, but the referring veterinarians reported the dogs to be asymptomatic. No major complications occurred. Conventional bone plates are suitable choices for stabilisation of distal radius and ulna fractures in toy breed dogs and are not necessarily correlated with high rates of complication. © 2016 Australian Veterinary Association.

  11. Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases.

    PubMed

    Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin

    2016-09-01

    To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57-75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1-4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2-3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

  12. Internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones using bioabsorbable screws.

    PubMed

    Mageed, M; Steinberg, T; Drumm, N; Stubbs, N; Wegert, J; Koene, M

    2018-03-01

    Fractures involving the proximal one-third of the splint bone are relatively rare and are challenging to treat. A variety of management techniques have been reported in the literature. The aim of this retrospective case series was to describe the clinical presentation and evaluate the efficacy of bioabsorbable polylactic acid screws in internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones in horses. The medical records, diagnostic images and outcome of all horses diagnosed with a proximal fracture of the splint bones and treated with partial resection and internal fixation of the proximal stump using bioabsorbable polylactic acid screws between 2014 and 2015 were reviewed. Eight horses met the inclusion criteria. The results showed that there were no complications encountered during screw placement or postoperatively. Six horses returned to full work 3 months after the operation and two horses remained mildly lame. On follow-up radiographs 12 months postoperatively (n = 2) the screws were not completely absorbed. The screws resulted in a cone-shaped radiolucency, which was progressively replaced from the outer margins by bone sclerosis. The use of bioabsorbable screws for fixation of proximal fractures of the splint bone appears to be a safe and feasible technique and may offer several advantages over the use of traditional metallic implants. © 2018 Australian Veterinary Association.

  13. Management of complications of open reduction and internal fixation of ankle fractures.

    PubMed

    Ng, Alan; Barnes, Esther S

    2009-01-01

    The management of complications resulting from the open reduction and internal fixation of ankle fractures is discussed in detail. The initial radiographic findings of the most common postsurgical complications of ankle fracture reduction are briefly discussed, namely lateral, medial, and posterior malleolar malunion or nonunion, syndesmotic widening, degenerative changes, and septic arthritis with or without concomitant osteomyelitis. Emphasis is placed on the management of these complications, with a review of the treatment options proposed in the literature, a detailed discussion of the authors' recommendations, and an inclusion of different case presentations.

  14. [Treatment of postoperative nonunion of fracture of lower limb with bone grafting by intervertebral disc endoscope].

    PubMed

    Zhang, Jianlin; Tan, Yu'e; Ye, Jun; Han, Fangmin

    2012-02-01

    To explore the effectiveness of bone grafting by intervertebral disc endoscope for postoperative nonunion of fracture of lower limb. Between August 2004 and August 2008, 40 patients (23 males and 17 females) with postoperative nonunion of femoral and tibial fracture, aged 20-63 years (mean, 41.5 years) were treated. Nonunion of fracture occurred at 10-16 months after internal fixation. During the first operation, the internal fixation included interlocking intramedullary nailing of femoral fracture in 12 cases and plate in 16 cases, and interlocking intramedullary nailing of tibial fractures in 9 cases and plate in 3 cases. The X-ray films showed hypertrophic nonunion in 24 cases, common nonunion in 3 cases, and atrophic nonunion in 13 cases. The average operation time was 61 minutes (range, 40-80 minutes), and the blood loss was 80-130 mL (mean, 100 mL). The hospitalization time were 6-11 days (mean, 8.1 days). Incisions healed by first intention in all patients with no complication of infection or neurovascular injury. Forty patients were followed up 10-16 months (mean, 12.3 months). The X-ray films showed that all patients achieved healing of fracture after 4-10 months (mean, 6.8 months). No pain, disfunction, or internal fixation failure occurred. Bone grafting by intervertebral disc endoscope is an effective method for treating postoperative nonunion of femoral and tibial fracture.

  15. Increased risk for complications following removal of hardware in patients with liver disease, pilon or pelvic fractures: A regression analysis.

    PubMed

    Brown, Bryan D; Steinert, Justin N; Stelzer, John W; Yoon, Richard S; Langford, Joshua R; Koval, Kenneth J

    2017-12-01

    Indications for removing orthopedic hardware on an elective basis varies widely. Although viewed as a relatively benign procedure, there is a lack of data regarding overall complication rates after fracture fixation. The purpose of this study is to determine the overall short-term complication rate for elective removal of orthopedic hardware after fracture fixation and to identify associated risk factors. Adult patients indicated for elective hardware removal after fracture fixation between July 2012 and July 2016 were screened for inclusion. Inclusion criteria included patients with hardware related pain and/or impaired cosmesis with complete medical and radiographic records and at least 3-month follow-up. Exclusion criteria were those patients indicated for hardware removal for a diagnosis of malunion, non-union, and/or infection. Data collected included patient age, gender, anatomic location of hardware removed, body mass index, ASA score, and comorbidities. Overall complications, as well as complications requiring revision surgery were recorded. Statistical analysis was performed with SPSS 20.0, and included univariate and multivariate regression analysis. 391 patients (418 procedures) were included for analysis. Overall complication rates were 8.4%, with a 3.6% revision surgery rate. Univariate regression analysis revealed that patients who had liver disease were at significant risk for complication (p=0.001) and revision surgery (p=0.036). Multivariate regression analysis showed that: 1) patients who had liver disease were at significant risk of overall complication (p=0.001) and revision surgery (p=0.039); 2) Removal of hardware following fixation for a pilon had significantly increased risk for complication (p=0.012), but not revision surgery (p=0.43); and 3) Removal of hardware for pelvic fixation had a significantly increased risk for revision surgery (p=0.017). Removal of hardware following fracture fixation is not a risk-free procedure. Patients with liver disease are at increased risk for complications, including increased risk for needing revision surgery following hardware removal. Patients having hardware removed following fixation for pilon fractures also are at increased risk for complication, although they may not require a return trip to the operating room. Finally, removal of pelvic hardware is associated with a higher return to the operating room. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. How well can step-off and gap distances be reduced when treating intra-articular distal radius fractures with fragment specific fixation when using fluoroscopy.

    PubMed

    Thiart, M; Ikram, A; Lamberts, R P

    2016-12-01

    Although fragment specific fixation has proved to be an effective treatment regime, it has not been established how successfully this treatment could be performed using fluoroscopy and what the added value of arthroscopy could be. Establish gap and step-off distances after in intra-articular distal radius fractures that have been treated with fragment specific fixation while using fluoroscopy. Forty-four patients with an intra-articular distal radius fracture were treated with fragment specific fixation while using fluoroscopy. After the treatment of the intra-articular distal radius fracture with fragment specific fixation and the use of fluoroscopy, but before the completion of the surgical intervention, all gap, and step-off distances were determined by using arthroscopy. In addition, the joint was checked for any other wrist pathologies. Arthroscopy after the surgical intervention showed that in 37 patients no gap distances could be detected, while in six patients a gap distance of≤2mm was found and in one patient, a gap distance of 3mm. Similarly, arthroscopy revealed no step-off distances in 33 patients, while in 11 patients a step-off distance of≤2mm was found. Although additional wrist pathologies were found in 48% of our population, only one patient needed surgical intervention. Three months after the surgical intervention wrist flexion was 41±10°, wrist extension 51±17°, ulnar deviation 19±10°, radial deviation 32±12° while patients could pronate and supinate their wrist to 85±5° and 74±20°, respectively. Intra-articular distal radius fractures can be treated successfully with fragment specific fixation and the use of fluoroscopy. As almost all gap and step-off distances could be reduced to an acceptable level, the scope for arthroscopy to further improve this treatment regime is limited. The functional outcome scores that were found 3 months after the surgical intervention were similar to what has been reported in other studies using different treatment option. These findings suggest that fragment specific fixation is a good alternative for treating intra-articular distal radius fractures. As in most cases, only fluoroscopy is needed for fragment specific fixation, this treatment technique is a good treatment option for resource-limited hospitals, setting who do not have access to arthroscopy. III, case-control study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Return to sport following clavicle fractures: a systematic review.

    PubMed

    Robertson, G A J; Wood, A M

    2016-09-01

    This review aims to provide information on the return rates and return times to sport following clavicle fractures. A systematic search of Medline, EMBASE, CINAHAL, Cochrane, Web of Science, PEDro, SPORTDiscus, Scopus and Google Scholar was performed using the keywords 'clavicle', 'clavicular', 'fractures', 'athletes', 'sports', 'non-operative', 'conservative', 'operative', 'return to sport'. Twenty-three studies were included: 10 reported on mid-shaft fractures, 14 on lateral fractures. The management principles for athletic patients were to attempt non-operative management for undisplaced fractures to undertake operative intervention for displaced lateral fractures and to recommend operative intervention for displaced mid-shaft fractures. The optimal surgical modality for mid-shaft and lateral clavicle fractures. Operative management of displaced mid-shaft fractures offers improved return rates and times to sport compared to non-operative management. Suture fixation and non-acromio-clavicular joint (ACJ)-spanning plate fixation of displaced lateral fractures show promising results. Future prospective studies should aim to establish the optimal treatment modalities for clavicle fractures. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Inferior angle of scapula fractures: a review of literature and evidence-based treatment guidelines.

    PubMed

    Chang, Angela C; Phadnis, Joideep; Eardley-Harris, Nathan; Ranawat, Vijai S; Bain, Gregory I

    2016-07-01

    Inferior angle of scapula (IAS) fractures are rare, with very few cases reported. They typically present with pain, loss of shoulder motion, and scapula winging. Operative and nonoperative treatments have been trialed with varying success. The aim of this study was to gather data relating to IAS fractures to develop evidence-based treatment guidelines as none are currently available. A search was conducted of the PubMed and Google Scholar databases to identify cases of IAS fractures. Data collected about each case included age and gender of the patient, mechanism of injury, fracture displacement, treatment, and outcome. The authors report 2 additional IAS fracture cases. Ten cases were identified for inclusion in this study, 8 from the literature and 2 described by the authors. Of the 10 cases, 7 described displaced IAS fractures and 3 described undisplaced fractures. All displaced fractures treated nonoperatively resulted in a painful nonunion. All that underwent operative fixation, whether acutely or after failed nonoperative treatment, had resolution of pain and a good functional outcome. All undisplaced fractures were treated nonoperatively; 1 had persisting pain. Surgical exploration identified the fracture fragment attached to serratus anterior in 2 cases and attached to both serratus anterior and latissimus dorsi in 2 cases. There are limited data available about IAS factures. From the cases reviewed, treatment recommendations include the following: (1) displaced IAS fractures should undergo operative fixation to prevent the development of a painful nonunion; (2) suture repair provides adequate fixation; and (3) undisplaced fractures have a variable outcome when treated nonoperatively. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. External fixation versus open reduction with locked volar plating for geriatric distal radius fractures.

    PubMed

    Lee, Daniel J; Elfar, John C

    2014-09-01

    The optimal management of displaced dorsal radius fractures (DRFs) in older patients remains an issue of debate. Bridging external fixation is a well-accepted treatment modality for severely comminuted DRFs, while open reduction and internal fixation with locked volar plating has emerged as a promising alternative in recent years. The current body of randomized trials supports the trend toward locked volar plating, as it allows for quicker improvement in subjective and functional outcomes. There is no clear evidence to suggest that one technique carries significantly less complications than the other. Locked volar plating should be considered in patients for whom an accelerated functional recovery would be advantageous. Otherwise, both external fixation and locked volar plating provide good long-term clinical outcomes.

  20. Pediatric maxillofacial fractures.

    PubMed

    Spring, P M; Cote, D N

    1996-05-01

    Maxillofacial trauma in the pediatric population is a relatively infrequent occurrence. Studies have demonstrated consistently that 5% of all facial fractures occur in children. The low percentage of facial fractures in this age group has been attributed, in part, to the lack of full pneumatization of the sinuses until later in childhood. Review of the literature indicates that boys are more commonly affected than girls and that the majority of pediatric facial fractures occur in children between 6 and 12 years of age. Motor vehicle accidents, falls, and blunt trauma are responsible for the largest number of pediatric facial fractures. The most common site of facial fracture is the nose and dentoalveolan complex, followed by the mandible, orbit, and midface in most pediatric cohorts. Management of the mandible is often conservative owing to the high percentage of isolated condylar fractures in children. Open reduction and internal fixation of pediatric facial fractures is indicated in complex mandible, midface, and orbital fractures. The effect of rigid fixation on facial skeleton growth is not completely understood.

  1. Exposure of the surgeon's hands to radiation during hand surgery procedures.

    PubMed

    Żyluk, Andrzej; Puchalski, Piotr; Szlosser, Zbigniew; Dec, Paweł; Chrąchol, Joanna

    2014-01-01

    The objective of the study was to assess the time of exposure of the surgeon's hands to radiation and calculate of the equivalent dose absorbed during surgery of hand and wrist fractures with C-arm fluoroscope guidance. The necessary data specified by the objective of the study were acquired from operations of 287 patients with fractures of fingers, metacarpals, wrist bones and distal radius. 218 operations (78%) were percutaneous procedures and 60 (22%) were performed by open method. Data on the time of exposure and dose of radiation were acquired from the display of the fluoroscope, where they were automatically generated. These data were assigned to the individual patient, type of fracture, method of surgery and the operating surgeon. Fixations of distal radial fractures required longer times of radiation exposure (mean 61 sec.) than fractures of the wrist/metacarpals and fingers (38 and 32 sec., respectively), which was associated with absorption of significantly higher equivalent doses. Fixations of distal radial fractures by open method were associated with statistically significantly higher equivalent doses (0.41 mSv) than percutaneous procedures (0.3 mSv). Fixations of wrist and metacarpal bone fractures by open method were associated with lower equivalent doses (0.34 mSv) than percutaneous procedures (0.37 mSv),but the difference was not significant. Fixations of finger fractures by open method were associated with lower equivalent doses (0.13 mSv) than percutaneous procedures (0.24 mSv), the difference being statistically non-significant. Statistically significant differences in exposure time and equivalent doses were noted between 4 surgeons participating in the study, but no definitive relationship was found between these parameters and surgeons' employment time. 1. Hand surgery procedures under fluoroscopic guidance are associated with mild exposure of the surgeons' hands to radiation. 2. The equivalent dose was related to the type of fracture, operative technique and - to some degree - to the time of employment of the surgeon.

  2. [Comparing clinical effects of titanic elastic nail and locking compression pine fixation in treating subtrochanteric fractures in older children].

    PubMed

    Zhu, Kang-xiang; Yin, Shan-qing

    2013-12-01

    To explore optimal choice of surgical treatment for subtrochanteric fractures in older children. A retrospective study of 36 older children with subtrochanteric fractures was performed between January 2010 and January 2012. Among them, 18 patients (11 males and 7 females) aged from 7 to 13 years old with an average of 9.4 were treated with titanic elastic nail (TEN) fixation, 4 cases were Type II A, 3 cases were II B, 2 cases were II C, 4 cases were III A, 3 cases were III B according to Seinsheimer classification. Eighteen patients (10 males and 8 females) aged was from 8 to 13 years with an average of 9.6 were treated with locking compression pine (LCP) fixation, and 3 cases were Type II A, 4 cases were II B, 3 cases were II C, 4 cases were IIIA, 2 cases were III B. Fracture healing time, postoperative complications (including wound infection, failure and breakage of internal fixtion, deformities of angular on the sagittal view, deformities of coxa vara) and recovery of hip joint function were observed and recorded. All children were followed up from 15 to 36 months with an average of 21. Fracture were all healed, the time ranged from 7 to 16 weeks (mean 9.5). Three cases in TEN group occurred mild deformities of angular on the sagittal view, 3 cases occurred deformities of coxa vara and 2 cases occurred limb shortening; while 1 case occurred mild deformities of angular on the sagittal view, and no deformities of coxa vara and limb shortening occurred in LCP group. No early close of epiphyseal injury, avascular necrosis of femoral head occurred. Clinical efficacy were evaluated by Sanders standard, 14 cases got excellent results, 3 cases were moderate in LCP group, while 9 cases in excellent, 4 in moderate in TEN group. There were no significant differences between two group in recovery of hip joint function and complications. For the treatment of subtrochanteric fractures in older children,the efficacy of LCP fixation is better than that of TFN fixation, which has advantages of reliable fixation, and less complications.

  3. Bi-Pedicle Fixation of Affected Vertebra in Thoracolumbar Burst Fracture.

    PubMed

    Padalkar, Pravin; Mehta, Varshil

    2017-04-01

    Burst fractures of the spine account for 14% of all spinal injuries and more than 50% of all thoracolumbar trauma. However, there is ambiguity while choosing the right treatment plan. Short Segment Pedicle screw Fixation (SSPF) has become an increasingly popular method of treatment of thoracolumbar burst fractures, providing the advantage of incorporating fewer motion segments in the fixation. Various biomechanical studies showed that the use of pedicle screws could achieve stable construct within short-segment fixation. To evaluate the efficacy of SSPF using longest possible screws in both pedicles of fractured vertebra. A retrospective chart review of 25 single burst thoracolumbar fracture patients, operated between May 2009 to 2015 in a tertiary care trauma center, was conducted. Preoperative and post-operative plain radiographs were evaluated for kyphotic angulations using the traditional Cobb method. Anterior Vertebral Height (AVH), Posteriors Vertebral Height (PVH) were measured preoperatively and immediate postoperatively. Average percentage loss of AVH and mid-sagittal height were calculated on preoperative and postoperative X-rays on follow up. Fourteen men and 11 women with an average age of 42.92 years comprised the study population. Mean age at the time of operation was 34.5±14.2 years. Mean operation time was 168±72 (minutes). Average hospitalization time was 9±7 (days). Mean blood loss was 515±485 (ml). There were two cases of postoperative infection and implant failure each. A mean of 15.2° of kyphosis correction was attained from pre-operation to post-operation (p<0.0001). Although, there was a 15° average improvement of kyphosis post-fixation, loss of correction over time was nearly 8°, resulting in a 7° mean correction of kyphosis. A mean loss of AVH on postoperative radiograph was 6.12% and maintained 12.4% at the time of review (p<0.001). Similarly, there was 32.8% mid-sagittal height loss at time of injury, which was improved to only 12.6% as compare to initial height loss (p<0.0001). In this study, we propose SSPF using longest possible screws in both pedicle of fractured vertebra. Bi-pedicular fixation gives significant radiological corrections.

  4. Surgical management for avulsion fracture of the calcaneal tuberosity.

    PubMed

    Yu, Guang-rong; Pang, Qing-jiang; Yu, Xiao; Chen, Da-wei; Yang, Yun-feng; Li, Bing; Zhou, Jia-qian

    2013-08-01

    To discuss the operative methods and curative effect of calcaneal tuberosity fracture. A retrospective study was done to analyze 15 patients with calcaneal tuberosity fracture who received surgical management between January 2008 and June 2011. There were nine males and six females, with the age ranging from 31 to 68 years (average, 51.4 years). All the patients had unilateral acute injury, with the left foot in 7 cases and the right foot in 8 cases. According to the Beavis classification, there were three cases in type I and 12 cases in type II. All the cases in type I and 10 cases in type II were treated with open reduction and screw fixation. The other two cases in type II with larger fragment involving a portion of the subtalar joint were treated with plate and screw fixation. The effect of the treatment was assessed according to the ankle and hindfoot score system of American Orthopaedic Foot and Ankle Society (AOFAS) after the operation. Ten patients were followed up for 12 to 36 months (average, 20 months). The healing time in these patients ranged from 8 to 25 weeks (average, 12 weeks). The postoperative score ranged from 47 to 100 points (average, 91.1 points). Seven cases were rated as excellent, two as good, and one as poor. The rate of excellent and good was 90%. Necrosis of skin and soft tissue and exposure of the plate happened in one patient, who eventually healed after 3 weeks by debridement with plate preserved and peroneal artery perforator flap transplantation. Loss of reduction happened to another patient, who was treated with revision surgery by open reduction and screw fixation again. To patients with obvious fracture displacement, whose soft tissues are irritated severely, emergency open reduction and internal fixation operation should be offered to prevent the necrosis of the flaps as far as possible. To patients with small fractures, it is advisable to choose open reduction and large diameter screw fixation, while plate and screw fixation may be better for the patients with large fragments, especially for those with the fracture line extending to the subtalar joint. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  5. Is lateral stabilization enough in thoracolumbar burst fracture reconstruction? A biomechanical investigation.

    PubMed

    Panchal, Ripul R; Matheis, Erika A; Gudipally, Manasa; Hussain, Mir M; Kim, Kee D; Bucklen, Brandon S

    2015-10-01

    Traditional reconstruction for burst fractures involves columnar support with posterior fixation at one or two levels cephalad/caudad; however, some surgeons choose to only stabilize the vertebral column. The aim was to distinguish biomechanical differences in stability between a burst fracture stabilized through a lateral approach using corpectomy spacers of different end plate sizes with and without integrated screws and with and without posterior fixation. This was an in vitro biomechanical study assessing thoracolumbar burst fracture stabilization. Six human spines (T11-L3) were tested on a six-degrees-of-freedom simulator enabling unconstrained range of motion (ROM) at ±6 N·m in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) after a simulated burst fracture at L1. Expandable corpectomy spacers with/without integrated screws (Fi/F; FORTIFY Integrated/FORTIFY; Globus Medical, Inc., Audubon, PA, USA) were tested with different end plate sizes (21×23 mm, 22×40-50 mm). Posterior instrumentation (PI) via bilateral pedicle screws and rods was used one level above and one level below the burst fracture. Lateral plate (LP) fixation was tested. Devices were tested in the following order: intact; Fi21×23; Fi21×23+PI; F21×23+PI+LP; F21×23+LP; F22×40-50+LP; F22×40-50+PI+LP; Fi22×40-50+PI; Fi22×40-50. In FE and AR, constructs without PI showed no significant difference (p<.05) in stability compared with intact. In LB, F22×40-50+LP showed a significant increase in stability relative to intact, but no other construct without PI reached significance. In FE and LB, circumferential constructs were significantly more stable than intact. In AR, no construct showed significant differences in motion when compared with the intact condition. Constructs without posterior fixation were the least stable of all tested constructs. Circumferential fixation provided greater stability in FE and LB than lateral fixation and intact. Axial rotation showed no significant differences in any construct compared with the intact state. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. [Influencing factors for trauma-induced tibial infection in underground coal mine].

    PubMed

    Meng, W Z; Guo, Y J; Liu, Z K; Li, Y F; Wang, G Z

    2016-07-20

    Objective: To investigate the influencing factors for trauma-induced tibial infection in underground coal mine. Methods: A retrospective analysis was performed for the clinical data of 1 090 patients with tibial fracture complicated by bone infection who were injured in underground coal mine and admitted to our hospital from January 1995 to August 2015, including the type of trauma, injured parts, severity, and treatment outcome. The association between risk factors and infection was analyzed. Results: Among the 1 090 patients, 357 had the clinical manifestations of acute and chronic bone infection, 219 had red and swollen legs with heat pain, and 138 experienced skin necrosis, rupture, and discharge of pus. The incidence rates of tibial infection from 1995 to 2001, from 2002 to 2008, and from 2009 to 2015 were 31%, 26.9%, and 20.2%, respectively. The incidence rate of bone infection in the proximal segment of the tibia was significantly higher than that in the middle and distal segments (42.1% vs 18.9%/27.1%, P <0.01) . As for patients with different types of trauma (Gustilo typing) , the patients with type III fracture had a significantly higher incidence rate of bone infection than those with type I/II infection (52.8% vs 21.8%/24.6%, P <0.01) . The incidence rates of bone infection after bone traction, internal fixation with steel plates, fixation with external fixator, and fixation with intramedullary nail were 20.7%, 43.5%, 21.4%, and 26.1%, respectively, suggesting that internal fixation with steel plates had a significantly higher incidence rate of bone infection than other fixation methods ( P <0.01) . The multivariate logistic regression analysis showed that the position of tibial fracture and type of fracture were independent risk factors for bone infection. Conclusion: There is a high incidence rate of trauma-induced tibial infection in workers in underground coal mine. The position of tibial fracture and type of fracture are independent risk factors for bone infection. Vacuum sealing drainage and Ilizarov technique can achieve a satisfactory therapeutic effect.

  7. Treatment of displaced talar neck fractures using delayed procedures of plate fixation through dual approaches.

    PubMed

    Xue, Youdi; Zhang, Hui; Pei, Fuxing; Tu, Chongqi; Song, Yueming; Fang, Yue; Liu, Lei

    2014-01-01

    Treatment of talar neck fractures is challenging. Various surgical approaches and fixation methods have been documented. Clinical outcomes are often dissatisfying due to inadequate reduction and fixation with high rates of complications. Obtaining satisfactory clinical outcomes with minimum complications remains a hard task for orthopaedic surgeons. In the period from May 2007 to September 2010, a total of 31 cases with closed displaced talar neck fractures were treated surgically in our department. Injuries were classified according to the Hawkins classification modified by Canale and Kelly. Under general anaesthesia with sufficient muscle relaxation, urgent closed reduction was initiated once the patients were admitted; if the procedure failed, open reduction and provisional stabilisation with Kirschner wires through an anteromedial approach with tibiometatarsal external fixation were performed. When the soft tissue had recovered, definitive fixation was performed with plate and screws through dual approaches. The final follow-up examination included radiological analysis, clinical evaluation and functional outcomes which were carried out according to the Ankle-Hindfoot Scale of the American Orthopaedic Foot and Ankle Society (AOFAS), patient satisfaction and SF-36. Twenty-eight patients were followed up for an average of 25 months (range 18-50 months) after the injury. Only two patients had soft tissue complications, and recovery was satisfactory with conservative treatment. All of the fractures healed anatomically without malunion and nonunion, and the average union time was 14 weeks (range 12-24 weeks). Post-traumatic arthritis developed in ten cases, while six patients suffered from avascular necrosis of the talus. Secondary procedures included three cases of subtalar arthrodesis, one case of ankle arthrodesis and one case of total ankle replacement. The mean AOFAS hindfoot score was 78 (range 65-91). According to the SF-36, the average score of the physical component summary was 68 (range 59-81), and the average score of the mental component summary was 74 (range 63-85). Talar neck fractures are associated with a high incidence of long-term disability and complications. Urgent reduction of the fracture-dislocation and delayed plate fixation through a dual approach when the soft tissue has recovered may minimise the complications and provide good clinical outcomes.

  8. Reoperation following open reduction and plate fixation of displaced mid-shaft clavicle fractures.

    PubMed

    Ashman, Bradley D; Slobogean, Gerard P; Stone, Trevor B; Viskontas, Darius G; Moola, Farhad O; Perey, Bertrand H; Boyer, Dory S; McCormack, Robert G

    2014-10-01

    Operative fixation of displaced, mid-shaft clavicle fractures has become an increasingly common practice. With this emerging trend, data describing patient outcomes with longer follow-up are necessary. We retrospectively reviewed the medical records of subjects treated with plate fixation for displaced mid-shaft clavicle fractures from 2003 to 2009 at a Level I trauma hospital. All subjects were greater than 12 months post-index surgery. Treatment involved ORIF with either a low-contact dynamic compression plate (LCDC) or a contoured plate (pre-contoured or pelvic reconstruction plate). Our primary outcome was reoperation for any indication. 143 subjects were included. The mean age was 36 ± 14 years and the mean time to reoperation or chart review was 33 months. Contoured plates were used in 64% of cases and LCDC plates were used in the remaining subjects. Twenty-nine subjects (20%) underwent reoperation: 23.5% of subjects treated with LCDC plates and 18.5% of subjects treated with contoured plates (p=0.52). Indications for reoperation included implant irritation (n=25), implant failure (n=2), and non-union (n=2). There was near statistically significant association with reoperation and female gender (p=0.05) but no association between reoperation and age (p=0.14), fracture class (p=0.53), plate type (p=0.49), or plate location (p=0.93). The mean QuickDASH score for the population surveyed was 8.8 (5.5-12.1; 95% CI) with near statistically significant and clinically relevant difference between those considering reoperation and those not 22.3 (8.6-36.0; 95% CI) versus 6.7 (3.6-9.8; 95% CI). This study represents a large series of displaced clavicle fractures treated with open reduction and plate fixation. Reoperation following plate fixation is relatively common, but primarily due to implant irritation. No difference in reoperation rates between plate types or location could be detected in our current sample size. Also, excellent functional outcomes continue to be observed several years after clavicle fracture fixation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. [Use of the Omega plate for stabilisation of acetabular fractures: first experience].

    PubMed

    Šrám, J; Taller, S; Lukáš, R; Endrych, L

    2013-01-01

    The aim of our study is to solve the problem of insufficient fixation of comminuted fractures of the quadrilateral plane and the iliopectineal line. These fixation problems occur while using the standard narrow 3.5 mm fixation plate applied from a modified Stoppa approach. A new plate developed by the authors--the Omega plate--fulfils the requirements. In the period 2010-2012, we performed 156 stabilisations of pelvic ring fractures and acetabular fractures. We used the modified Stoppa approach applying the standard fixation plate in 24 patients and the Omega plate in 15 patients. The patient group with the Omega plate included 10 male and five female patients with the average age of 61 years (range, 30-72). Only 11 patients were followed up, with an average period of 13.3 months, because one patient was lost to followup and three patients were shortly after surgery. The surgical technique of Omega plate application is described in detail. The clinical evaluation of post-operative results was based on the Harris Hip Score; the graphical results were rated using the Matta and Pohlemann criteria. The Stoppa approach alone was used in four patients, combination of two approaches (Stoppa and Kocher-Langenbeck approach) was used in six cases and three approaches were employed in five patients. No adverse intra- or post-operative events were recorded. Excellent or satisfactory graphical results were obtained in 12 patients and an unsatisfactory graphical outcome was recorded in three cases. In the follow-up period ranging from 8 to 22 months, 11 patients healed. Late complications included avascular femoral head necrosis in two and severe post-traumatic coxarthrosis in three patients. Due to these complications, all five patients underwent total hip arthroplasty without previous Omega plate removal at an average interval of 15 months from the primary pelvic surgery. They were not included in the follow-up evaluation. The remaining six patients had an average Harris Hip Score of 88 points (range, 81-98). The novel plate, shaped as a reverse omega letter, enables fixation of the quadrilateral area of the acetabulum through pressure of the arc of the plate against this area. Hitches, with holes for screw insertion, attached to the Omega plate in its middle part allow for fixation of fragments above the linea arcuata simply by pressure. Hitches in the ventral part provide for plate fixation to the ventral acetabular column and the superior pubic ramus. Hitches in the posterior segment of the plate facilitate insertion of a long screw in the posterior acetabular column from an additional iliac approach for stabilisation of simple acetabular fractures. The Omega plates are manufactured in several modifications. The Omega plate enables us to fix fractures of the superior pubic ramus, fractures of the anterior acetabular column, fractures of the quadrilateral acetabular plate, fractures in the iliopectineal line and simple fractures of the posterior column. A CT-defined projection of the pelvic inlet based on pre-operative CT scans allows us to choose the appropriate plate size and to shape the plate pre-operatively. After a technically well performed Stoppa approach and good fragment reduction, the application of an Omega plate is easy if our recommendations are followed. Fixation of all fragments of the anterior column and the quadrilateral plate is very stable and the Omega plate is highly resistant to secondary loss of reduction. A potential total hip arthroplasty does not require Omega plate removal.

  10. [The clinical effect of anti-rotation reduction internal fixator on the treatment of fresh thoracolumbar spine fracture].

    PubMed

    Pan, Xianming; Quan, Yi; Tan, Yingjun; Zhang, Bo; Wang, Yuanshan; Huang, Tong; Ma, Zehui; Liao, Dongfa; Li, Ting; Liu, Jinbiao

    2005-03-15

    To evaluate the effect of self-designed anti-rotation reduction internal fixator (ARRIF) on treating different spine segment fracture. From August 1999 to March 2003, 76 patients(48 males and 28 females, aged from 22 to 59 with an average of 34.1) with thoracolumbar fracture were operatively treated by ARRIF. The follow-up period ranged from 6 to 21 months (15 months in average). Classification according to injury segment: flexion compression fracture 27 cases, burst fracture 42 cases, flexion distraction injury 3 cases, flexion revolving type fracture dislocation 2 cases, shear force type dislocation 2 cases. Classification according Frankel's grade: A grade 16 cases, B grade 15 cases, C grade 27 cases, D grade 10 cases, E grade 8 cases. Operation duration, volume of bleeding, incidence post-operation complication and effect of reduction-fixation were observed. The operation duration of ARRIF was 1.2 h in average, and there was about 200 ml volume of bleeding during operation. The nerve function showed one Frankel's grade improvement after operation were as follows: A grade 8 cases (50%), B grade 11 cases (73.3%), C grade 20 cases (74.1%), D grade 3 cases (30%); 2 Frankel's E cases have no nerve function changes. The nerve function damage have no aggravation in all the patients, the postoperation Cobb's angle was averagely corrected 22 degrees. The horizontal displacement of dislocation vertebrae was averagely corrected 28% in sagittal plane, the statistical analysis had significant variance (P < 0.01). ARRIF had no complications of the breakage of screws and rods. ARRIF proves to be a valid internal fixator in reducing and fixing different thoracic lumbar segment spine fracture.

  11. Comminuted distal femur closed fractures: a new application of the Ilizarov concept of compression-distraction.

    PubMed

    El-Tantawy, Ahmad; Atef, Ashraf

    2015-04-01

    The treatment of intra-articular distal femur fractures with severe metaphyseal comminution is challenging. It is important to choose a technique that provides secure fixation, minimum tissue handling, and early ambulation. The aim of this work was to evaluate the outcomes of application of Ilizarov concept as an early definitive treatment of comminuted distal femur closed fractures. A total of 17 male patients (mean age 28.53±6.33 years) presented with comminuted distal femur fractures (with 10 type C2 and 7 type C3-2 fractures according to AO/ASIF system) were included in this prospective study. Initial fixation of the articular fragments was done by inter-fragmentary screws, percutaneously through a limited open approach, and stabilization was completed by Ilizarov fixator. The procedure included acute shortening, through the comminution, followed by gradual re-distraction to compensate the created shortening. Radiological and functional results were assessed according to ASAMI evaluation system. The mean amount of intra-operative shortening was 3.68±0.53 cm. The mean external fixation index was 37.24±2.53 days/cm. The mean follow-up period was 18.18±1.91 months. All fractures united primarily in an average 137.65±4.12 days, with no evident angular deformity or limb-length discrepancy. None of the cases required a second major procedure or bone graft. The functional results were excellent in three cases, good in 12, and fair in two patients. The Ilizarov concept of acute compression-distraction is a valuable alternative for the treatment of distal femur fractures with severe metaphyseal comminution.

  12. Operative Fixation for Clavicle Fractures-Socioeconomic Differences Persist Despite Overall Population Increases in Utilization.

    PubMed

    Schairer, William W; Nwachukwu, Benedict U; Warren, Russell F; Dines, David M; Gulotta, Lawrence V

    2017-06-01

    Clavicle fractures were traditionally treated conservatively, but recent evidence has shown improved outcomes with surgical management. The purpose of this study was to evaluate the recent trends in operative treatment of clavicle fractures, and to analyze for patient related factors that may affect treatment strategy. The Healthcare Cost and Utilization Project (HCUP) California and Florida inpatient, outpatient, and the Emergency Department databases were used to identify all patients with clavicle fractures between 2005 and 2010. We evaluated the overall number of procedures over the study period and calculated the rates of operative and nonoperative treatment by tracking a large cohort of emergency department patients with clavicle fractures. Poisson and multivariable regression were used to identify trends and patient factors associated with treatment. There was a 290% increase in the annual number clavicle fracture procedures over the study period. The rate of fixation increased from 3.7% to 11.1% (P < 0.001). Significant increases were seen in all patient age groups less than 65 years. Comparatively, higher rates of fixation were found in patients who were white, privately insured, and of high-income status. Lower income status was also associated with delayed surgery. The rates of clavicle fracture fixation have increased. However, there are differences associated with socioeconomic factors including race, insurance type, and income level. In part, this likely representing both underutilization and overutilization but may also show differential access to care. This differential utilization suggests both that further work is needed to more clearly define indications for operative versus nonoperative management and to further evaluate referral systems and access to care to ensure equal and quality treatment is available for all patients. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. [Early operative treatment of pelvic fractures associated with urethral disruption].

    PubMed

    Jia, Jian; Guo, Lu-Zeng; Wu, Chang-Lin; Chen, Jia-Geng; Zhang, Tie-Liang; Pei, Fu-Xing

    2007-02-15

    To evaluate the early operative treatment and clinical results of pelvic fractures associated with urethra disruption. From January 1995 to January 2005, 25 patients suffered from pelvic fractures combined urethra disruption treated by operation were retrospectively analyzed. According to Tile's classification, 1 case was stable pelvic fracture, 17 rotational unstable fractures, and 7 rotational combined vertical unstable fractures. The complete urethra rupture were in 23 cases and incomplete in 2 cases. The operative methods included: (1) emergency open reduction and internal fixation of the pelvis combined primary urethra suturing in 2 cases, partial suturing after realignment in 4 cases, realignment in 2 cases, and urethrovaginal penetrating wound repairing in 1 case; (2) primary urethra realignment only and delayed (range, 7 to 21 days) pelvic internal fixation in 10 cases; (3) early cystostomy and delayed (range, 3 to 21 days) urethra realignment and pelvic internal fixation in 6 cases. The mean follow-up time of all patients was 34 months (range from 6 to 120 months). According to Majeed's evaluation, 17 cases of pelvic injury showed excellent results, 5 good, and 3 fare. After urinary catheter removed, the mean maximal urine flow rate of 19 (76%) patients was 18.6 ml/s and the mean scar length between both disrupted ends on the film of excretion urethrography was 0.51 cm. Five (20%) cases suffered in dysuria needed urethral dilatation or further surgery. One (4%) female could not control urination who need a second-look operation. The primary suprapubic soft tissue avulsion wound infection secondary to retropubic abscess was found in 1 case, posterior urethra-stenosis in 5 cases, sexual impotence in 3 cases, and incontinence in 1 case. The satisfactory reduction and effective fixation of the pelvic fractures is an anatomical basis for receiving "tension-free urethral anastomosis".

  14. Implant Removal After Internal Fixation of a Femoral Neck Fracture: Effects on Physical Functioning.

    PubMed

    Zielinski, Stephanie M; Heetveld, Martin J; Bhandari, Mohit; Patka, Peter; Van Lieshout, Esther M M

    2015-09-01

    The effect of implant removal after internal fixation of a femoral neck fracture on physical functioning was analyzed. Characteristics of patients who had their implant removed were studied, as it is currently unknown from which type of patients implants are removed and what effect removal has on function. Secondary cohort study alongside a randomized controlled trial. Multicenter study in 14 hospitals. Patients who had their implant removed after internal fixation of a femoral neck fracture are compared with patients who did not. Patient characteristics and quality of life (Short Form 12, Western Ontario McMaster Osteoarthritis Index) were compared. Matched pairs were selected based on patient/fracture characteristics and prefracture physical functioning. Of 162 patients, 37 (23%) had their implant removed. These patients were younger (median age: 67 vs. 72 years, P = 0.024) and more often independently ambulatory prefracture (100% vs. 84%, P = 0.008) than patients who did not. They more often had evident implant back-out on x-rays (54% vs. 34%, P = 0.035), possibly related to a higher rate of Pauwels 3 fractures (41% vs. 22%, P = 0.032). In time, quality of life improved more in implant removal patients [+2 vs. -4 points, Short Form 12 (physical component), P = 0.024; +9 vs. 0 points, Western Ontario McMaster Osteoarthritis Index, P = 0.019]. Implant removal after internal fixation of a femoral neck fracture positively influenced quality of life. Implant removal patients were younger and more often independently ambulatory prefracture, more often had a Pauwels 3 fracture, and an evident implant back-out. Implant removal should be considered liberally for these patients if pain persists or functional recovery is unsatisfactory. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  15. [Clinical application of atlas translaminar screws fixation in treatment of atlatoaxial instability].

    PubMed

    Wang, Guoyou; Fu, Shijie; Shen, Huarui; Guan, Taiyuan; Xu, Ping

    2013-10-01

    To explore the effectiveness of fixation of atlas translaminar screws in the treatment of atlatoaxial instability. A retrospective analysis was made on the clinical data of 32 patients with atlatoaxial instability treated with atlantoaxial trans-pedicle screws between March 2007 and August 2009. Of them, 7 patients underwent atlas translaminar screws combined with axis transpedicle screws fixation because of fracture types, anatomic variation, and intraoperative reason, including 5 males and 2 females with an average age of 48.2 years (range, 35-69 years). A total of 9 translaminar screws were inserted. Injury was caused by traffic accident in 4 cases, falling from height in 2 cases, and crushing in 1 case. Two cases had simple odontoid fracture (Anderson type II), and 5 cases had odontoid fracture combined with other injuries (massa lateralis atlantis fracture in 2, atlantoaxial dislocation in 1, and Hangman fracture in 2). The interval between injury and operation was 4-9 days (mean, 6 days). The preoperative Japanese Orthopaedic Association (JOA) score was 8.29 +/- 1.60. The X-ray films showed good position of the screws. Healing of incision by first intention was obtained, and no patient had injuries of the spinal cord injury, nerve root, and vertebral artery. Seven cases were followed up 9-26 months (mean, 14 months). Good bone fusion was observed at 8 months on average (range, 6-11 months). No loosening, displacement, and breakage of internal fixation, re-dislocation and instability of atlantoaxial joint, or penetrating of pedicle screw into the spinal canal and the spinal cord occurred. The JOA score was significantly improved to 15.29 +/- 1.38 at 6 months after operation (t = 32.078, P = 0.000). Atlas translaminar screws fixation has the advantages of firm fixation, simple operating techniques, and relative safety, so it may be a remedial measure of atlatoaxial instability.

  16. Evaluation and treatment recommendations for acute injuries to the ankle syndesmosis without associated fracture.

    PubMed

    Miller, Timothy L; Skalak, Timothy

    2014-02-01

    Ankle ligamentous injuries are commonly seen in athletes in a variety of sports. Surveys of physicians and trainers of professional sports teams have identified syndesmotic injuries as among the most difficult to treat. In particular, injuries of the ankle syndesmosis have been strongly linked with a prolonged recovery and increased time to return to play. Due to sudden external rotation with the tibiotalar joint in dorsiflexion, these structures are commonly injured in association with fractures of the distal fibula. Surgery is indicated in cases with associated fractures and ligamentous instability, but optimal treatment for syndesmosis injuries without an associated fracture is less clear. A thorough history and physical examination, as well as appropriate imaging, are necessary to effectively diagnose and classify the injury. For stable injuries, short-term immobilization and functional rehabilitation is recommended. Unstable Grade 2 and 3 injuries require surgical fixation. Debate currently exists over rigid screw fixation versus suture button techniques as the ideal fixation method.

  17. Toxic shock syndrome post open reduction and Kirschner wire fixation of a humeral lateral condyle fracture.

    PubMed

    Chan, Yuen; Selvaratnam, Veenesh; Garg, Neeraj

    2015-08-11

    Use of Kirschner wires (K-wires) is the most common method of fracture stabilisation in lateral condyle fracture fixation in children. We report a case of toxic shock syndrome (TSS) following an open reduction and internal fixation using K-wires for a humeral lateral condyle fracture in a 5-year-old girl. TSS is a toxin-mediated multisystem illness. It typically presents with shock and it is most often attributed to toxin-producing strains of Staphylococcus aureus and Streptococcus pyogenes. It can lead to multiorgan failure and, ultimately, death. It is important to be aware of TSS, as it can present within any setting. Patients often have non-specific symptoms and their condition can worsen rapidly. TSS postorthopaedic surgery is rare; however, due to the serious nature of this disease, it is important to promptly recognise and diagnose TSS, and to ensure appropriate treatment is started without delay. 2015 BMJ Publishing Group Ltd.

  18. Arthroscopic Pullout Fixation for a Small and Comminuted Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia

    PubMed Central

    Nakagawa, Shuji; Arai, Yuji; Hara, Kunio; Inoue, Hiroaki; Hino, Manabu; Kubo, Toshikazu

    2017-01-01

    We describe a patient who underwent arthroscopic pullout fixation for a posterior cruciate ligament (PCL) avulsion fracture. A 46-year-old female, injured in a fall while riding a motorcycle, was diagnosed with a right knee PCL tibial attachment avulsion fracture and underwent arthroscopic osteosynthesis. A Kirschner wire was drilled to a point just medial to the medial border of the anterior tibial bony bed. A suture wire was folded into a loop and introduced into the posteromedial compartment via the bone tunnel. A fixation thread was inserted from the posteromedial portal, through the medial and lateral loop wires, and into the posteromedial compartment. The lateral and medial loop wires attached to the thread were pulled to the outside, and the thread was fixed onto the tibia. Three months post-surgery, she returned to her job. This procedure represents a minimally invasive method of treating avulsion fractures of the tibial attachment of the PCL. PMID:29172392

  19. Endoscopic subcondylar fracture repair: functional, aesthetic, and radiographic outcomes.

    PubMed

    Lee, C; Mueller, R V; Lee, K; Mathes, S J

    1998-10-01

    An endoscopic method of mandibular subcondylar fracture repair has been described recently. To determine the effectiveness of this new technique, we longitudinally studied functional, aesthetic, and radiographic parameters following endoscopic repair of 22 subcondylar fractures in 20 patients. Restoration of mandibular function was achieved without postoperative maxillomandibular fixation. Premorbid occlusion was restored. Clinical jaw motion was found to progressively increase with a mean interincisal jaw opening of 43 mm achieved after the eighth postoperative week. Patients were pleased with the aesthetic restoration of their chin projection,jaw line, and the symmetric midline movement of the chin point onjaw opening. Anatomic fracture reduction with rigid plate fixation was confirmed on early postsurgical radiographs. Late radiographs showed fracture union without remodeling of the condylar head. Endoscopic subcondylar fracture repair was efficacious at functional, aesthetic, and radiographic restoration of the mandible.

  20. Damage control and intramedullary nailing for long bone fractures in polytrauma patients.

    PubMed

    Patka, Peter

    2017-06-01

    The early fracture treatment in patients with multiple injuries should be focused on damage control. The fracture type and its location, local soft tissue condition as well as the patient's physiological condition shall determine the time and type of fracture treatment. Prevention of local and systemic complications must be immediately considered and included in the treatment planning. The use of external fixator (ExFix), which will be replaced by IM-implants in most cases at a later stage, provides adequate temporary fracture stabilization with less collateral damage. Good clinical results can be expected in patients with long bone fractures if the principles of damage control surgery are applied and local complications are prevented through proper reduction, firm fixation, early soft tissue reconstruction, and early rehabilitation. Copyright © 2017 Elsevier Ltd. All rights reserved.

Top