Sample records for fracture reduction evaluation

  1. Corrective Septorhinoplasty in Acute Nasal Bone Fractures.

    PubMed

    Kim, Jisung; Jung, Hahn Jin; Shim, Woo Sub

    2018-03-01

    Closed reduction is generally recommended for acute nasal bone fractures, and rhinoplasty is considered in cases with an unsatisfactory outcome. However, concomitant rhinoplasty with fracture reduction might achieve better surgical outcomes. This study investigated the surgical techniques and outcomes in patients who underwent rhinoplasty and fracture reduction concomitantly, during the acute stage of nasal bone fracture. Forty-five patients who underwent concomitant rhinoplasty and fracture reduction were enrolled. Nasal bone fractures were classified into three major types (type I, simple fracture; type II, fracture line that mimics nasal osteotomy; and type III, comminuted fracture) based on computed tomography images and preoperative facial images. Two independent otolaryngology-head and neck surgeons evaluated the surgical outcomes and telephone based survey were made to evaluate patients satisfaction. Among 45 patients, there were 39 males and 6 females. Type I was the commonest type of fracture with 18 patients (40%), while the most frequently used surgical technique for corrective surgery was dorsal augmentation with 44 patients (97.8%). The mean visual analogue scale satisfaction score of the surgeons and patients were 7.62 and 8, respectively, with no significant differences between fracture types. Concomitant rhinoplasty with fracture reduction can be performed for acute nasal bone fracture patients, and it might lead to better aesthetic outcomes.

  2. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    PubMed

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  3. Haptic computer-assisted patient-specific preoperative planning for orthopedic fractures surgery.

    PubMed

    Kovler, I; Joskowicz, L; Weil, Y A; Khoury, A; Kronman, A; Mosheiff, R; Liebergall, M; Salavarrieta, J

    2015-10-01

    The aim of orthopedic trauma surgery is to restore the anatomy and function of displaced bone fragments to support osteosynthesis. For complex cases, including pelvic bone and multi-fragment femoral neck and distal radius fractures, preoperative planning with a CT scan is indicated. The planning consists of (1) fracture reduction-determining the locations and anatomical sites of origin of the fractured bone fragments and (2) fracture fixation-selecting and placing fixation screws and plates. The current bone fragment manipulation, hardware selection, and positioning processes based on 2D slices and a computer mouse are time-consuming and require a technician. We present a novel 3D haptic-based system for patient-specific preoperative planning of orthopedic fracture surgery based on CT scans. The system provides the surgeon with an interactive, intuitive, and comprehensive, planning tool that supports fracture reduction and fixation. Its unique features include: (1) two-hand haptic manipulation of 3D bone fragments and fixation hardware models; (2) 3D stereoscopic visualization and multiple viewing modes; (3) ligaments and pivot motion constraints to facilitate fracture reduction; (4) semiautomatic and automatic fracture reduction modes; and (5) interactive custom fixation plate creation to fit the bone morphology. We evaluate our system with two experimental studies: (1) accuracy and repeatability of manual fracture reduction and (2) accuracy of our automatic virtual bone fracture reduction method. The surgeons achieved a mean accuracy of less than 1 mm for the manual reduction and 1.8 mm (std [Formula: see text] 1.1 mm) for the automatic reduction. 3D haptic-based patient-specific preoperative planning of orthopedic fracture surgery from CT scans is useful and accurate and may have significant advantages for evaluating and planning complex fractures surgery.

  4. Reduction and internal fixation of displaced intra-articular calcaneal fractures with a locking nail: a prospective study of sixty nine cases.

    PubMed

    Simon, P; Goldzak, M; Eschler, A; Mittlmeier, T

    2015-10-01

    The best treatment for intra-articular fractures of the calcaneus is still debated. The aims of this study were to determine whether intrafocal reduction of thalamic fractures is effective, to evaluate whether a locking nail is able to maintain reduction of the articular surface and to analyse the functional results of this original method. This prospective study assessed 69 fractures treated with a locking fracture nail in 63 cases and with primary subtalar fusion in six (Calcanail (®), FH). Articular congruity and global reduction of the calcaneus was assessed in all patients by computed tomography (CT) scan three months postoperatively. Functional results were evaluated according to the American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Score (AOFAS-AHS) and all complications recorded. For the 63 fracture nails, the average AOFAS score was 85.9 at a mean final follow-up of 12 months. Only three secondary fusions were performed. For the six comminuted fractures requiring primary fusion, the average AOFAS score was 75.9 at the last follow-up. The posterior intrafocal approach for both reduction and locked nailing of intra-articular calcaneal fractures has been proven as an effective and reliable procedure.

  5. Comparative evaluation of fracture resistance of Ceramic Veneer with three different incisal design preparations - An In-vitro Study.

    PubMed

    Jankar, Ajit S; Kale, Yogesh; Kangane, Suresh; Ambekar, Anand; Sinha, Manish; Chaware, Sachin

    2014-02-01

    Ceramic veneer fracture has occurred mainly at the incisal edge of the veneer because of greater stress. This study compares and evaluates the fracture resistance ceramic veneers with three different incisal preparations. 15 human permanent maxillary central incisor extracted were selected which were divided into three groups of 5 each having a different Incial design Preparation. Group 1: No Incisal reduction with facio- incisal bevel, Group 2 : 1 mm incisal reduction with butt joint, Group 3 : 1 mm incisal reduction with 1 mm height of Palatal chamfer. It was found that Group III had greater fracture resistance as compared to Group I and Group II. Group I had least fracture resistance as compared to Group II and III. Group II had greater fracture resistance as compared to Group I but less than Group III. Ceramic veneer with 1mm incisal reduction with 1mm height of palatal chamfer showed highest fracture resistance as compared to 1mm incisal reduction with butt joint and no incisal reduction with facial-incisal bevel, in order to achieve better esthetic and functional results. The palatal chamfer margin results in preservation of some peripheral enamel layer, which eliminates the micro leakage at the palatal margin-restoration interface and also effectively counteracting shear stress. This design provides a definite seat for cementation. How to cite the article: Jankar AS, Kale Y, Kangane S, Ambekar A, Sinha M, Chaware S. Comparative evaluation of fracture resistance of Ceramic Veneer with three different incisal design preparations - An In-vitro Study. J Int Oral Health 2014;6(1):48-54.

  6. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    PubMed

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having <1.5 mm of malreduction. Follow-up was available for 9 patients from 9 to 21 months after surgery. All of the fractures had healed. One minor (wire migration) and one major (implant failure) complication occurred. Mean lameness scores were 0 (n = 6), 0.5 (n = 2), and 1 (n = 1) at the time of final follow-up. No significant differences were found in follow-up ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  7. Applications of Computer-Assisted Navigation for the Minimally Invasive Reduction of Isolated Zygomatic Arch Fractures.

    PubMed

    Li, Zhi; Yang, Rong-Tao; Li, Zu-Bing

    2015-09-01

    Computer-assisted navigation has been widely used in oral and maxillofacial surgery. The purpose of this study was to describe the applications of computer-assisted navigation for the minimally invasive reduction of isolated zygomatic arch fractures. All patients identified as having isolated zygomatic arch fractures presenting to the authors' department from April 2013 through November 2014 were included in this prospective study. Minimally invasive reductions of isolated zygomatic arch fractures were performed on these patients under the guidance of computer-assisted navigation. The reduction status was evaluated by postoperative computed tomography (CT) 1 week after the operation. Postoperative complications and facial contours were evaluated during follow-up. Functional recovery was evaluated by the difference between the preoperative maximum interincisal mouth opening and that at the final follow-up. Twenty-three patients were included in this case series. The operation proceeded well in all patients. Postoperatively, all patients displayed uneventful healing without postoperative complication. Postoperative CT showed exact reduction in all cases. Satisfactory facial contour and functional recovery were observed in all patients. The preoperative maximal mouth opening ranged from 8 to 25 mm, and the maximal mouth opening at the final follow-up ranged from 36 to 42 mm. Computer-assisted navigation can be used not only for guiding zygomatic arch fracture reduction, but also for assessing reduction. Computer-assisted navigation is an effective and minimally invasive technique that can be applied in the reduction of isolated zygomatic arch fractures. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  8. External skeletal fixator intramedullary pin tie-in for the repair of tibiotarsal fractures in raptors: 37 cases (1995-2011).

    PubMed

    Bueno, Irene; Redig, Patrick T; Rendahl, Aaron K

    2015-11-15

    To evaluate the outcome of the application of an external skeletal fixator intramedullary pin tie-in (TIF) to tibiotarsal fractures in raptors. Retrospective case series. Thirty-four raptors with 37 tibiotarsal fractures. Medical records and radiographs for raptors with tibiotarsal fractures that were treated at The Raptor Center at the University of Minnesota between 1995 and 2011 were reviewed. Descriptive statistics were generated and univariate logistic regression analyses were used to assess whether age, sex, body weight, location and nature of the fracture, and type of surgical reduction were significantly associated with whether the fracture healed following surgical reduction and TIF application. 31 of 37 (84%) tibiotarsal fractures successfully healed following surgical reduction and TIF application. The mean healing time was 38 days (range, 15 to 70 days). None of the variables assessed were significantly associated with whether the tibiotarsal fracture healed. Twenty of the 34 (59%) raptors were eventually rehabilitated and released. Results indicated that most tibiotarsal fractures were successfully managed by surgical reduction and stabilization with a TIF. However, other comorbidities (eg, systemic infections and visual deficits) negatively affected the rehabilitation of raptors and sometimes resulted in euthanasia despite the fact that the tibiotarsal fracture had healed, and those comorbidities, along with the variables evaluated (eg, age, sex, and nature of the fracture), should be used as triage criteria and prognostic indicators.

  9. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    PubMed Central

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    In the treatment of mandibular condyle fracture, conservative treatment using closed reduction or surgical treatment using open reduction can be used. Management of mandibular condylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma. For each type of condylar fracture,the treatment method must be chosen taking into consideration the presence of teeth, fracture height, patient'sadaptation, patient's masticatory system, disturbance of occlusal function, and deviation of the mandible. In the past, closed reduction with concomitant active physical therapy conducted after intermaxillary fixation during the recovery period had been mainly used, but in recent years, open treatment of condylar fractures with rigid internal fixation has become more common. The objective of this review was to evaluate the main variables that determine the choice of an open or closed method for treatment of condylar fractures, identifying their indications, advantages, and disadvantages, and to appraise the current evidence regarding the effectiveness of interventions that are used in the management of fractures of the mandibular condyle. PMID:22872831

  10. Real-world effectiveness of osteoporosis therapies for fracture reduction in post-menopausal women.

    PubMed

    Yusuf, Akeem A; Cummings, Steven R; Watts, Nelson B; Feudjo, Maurille Tepie; Sprafka, J Michael; Zhou, Jincheng; Guo, Haifeng; Balasubramanian, Akhila; Cooper, Cyrus

    2018-03-21

    Studies examining real-world effectiveness of osteoporosis therapies are beset by limitations due to confounding by indication. By evaluating longitudinal changes in fracture incidence, we demonstrated that osteoporosis therapies are effective in reducing fracture risk in real-world practice settings. Osteoporosis therapies have been shown to reduce incidence of vertebral and non-vertebral fractures in placebo-controlled randomized clinical trials. However, information on the real-world effectiveness of these therapies is limited. We examined fracture risk reduction in older, post-menopausal women treated with osteoporosis therapies. Using Medicare claims, we identified 1,278,296 women age ≥ 65 years treated with zoledronic acid, oral bisphosphonates, denosumab, teriparatide, or raloxifene. Fracture incidence rates before and after treatment initiation were described to understand patients' fracture risk profile, and fracture reduction effectiveness of each therapy was evaluated as a longitudinal change in incidence rates. Fracture incidence rates increased during the period leading up to treatment initiation and were highest in the 3-month period most proximal to treatment initiation. Fracture incidence rates following treatment initiation were significantly lower than before treatment initiation. Compared with the 12-month pre-index period, there were reductions in clinical vertebral fractures for denosumab (45%; 95% confidence interval [CI] 39-51%), zoledronic acid (50%; 95% CI 47-52%), oral bisphosphonates (24%; 95% CI 22-26%), and teriparatide (72%; 95% CI 69-75%) during the subsequent 12 months. Relative to the first 3 months after initiation, clinical vertebral fractures were reduced for denosumab (51%; 95% CI 42-59%), zoledronic acid (25%; 95% CI 17-32%), oral bisphosphonates (23%; 95% CI 20-26%), and teriparatide (64%; 95% CI 58-69%) during the subsequent 12 months. In summary, reductions in fracture incidence over time were observed in cohorts of patients treated with osteoporosis therapies.

  11. Medial joint space widening of the ankle in displaced Tillaux and Triplane fractures in children.

    PubMed

    Gourineni, Prasad; Gupta, Asheesh

    2011-10-01

    Tillaux and Triplane fractures occur in children predominantly from external rotation mechanism. We hypothesized that in displaced fractures, the talus would shift laterally along with the distal fibula and the distal tibial epiphyseal fragment increasing the medial joint space. Consecutive cases evaluated retrospectively. Level I and Level II centers. Twenty-two skeletally immature patients with 14 displaced Triplane fractures and eight displaced Tillaux fractures were evaluated for medial joint space widening. Measurement of fracture displacement and medial joint space widening before and after intervention. Thirteen Triplane and six Tillaux fractures (86%) showed medial space widening of 1 to 9 mm and equal to the amount of fracture displacement. Reduction of the fracture reduced the medial space to normal. There were no known complications. Medial space widening of the ankle may be a sign of ankle fracture displacement. Anatomic reduction of the fracture reduces the medial space and may improve the results in Tillaux and Triplane fractures.

  12. Screw-Wire Osteo-Traction: An Adjunctive or Alternative Method of Anatomical Reduction of Multisegment Midfacial Fractures? A Description of Technique and Prospective Study of 40 Patients

    PubMed Central

    O'Regan, Barry; Devine, Maria; Bhopal, Sats

    2013-01-01

    Stable anatomical fracture reduction and segment control before miniplate fixation can be difficult to achieve in comminuted midfacial fractures. Fracture mobilization and reduction methods include Gillies elevation, malar hook, and Dingman elevators. No single method is used universally. Disadvantages include imprecise segment alignment and poor segment stability/control. We have employed screw-wire osteo-traction (SWOT) to address this problem. A literature review revealed two published reports. The aims were to evaluate the SWOT technique effectiveness as a fracture reduction method and to examine rates of revision fixation and plate removal. We recruited 40 consecutive patients requiring open reduction and internal fixation of multisegment midfacial fractures (2009–2012) and employed miniplate osteosynthesis in all patients. SWOT was used as a default reduction method in all patients. The rates of successful fracture reduction achieved by SWOT alone or in combination and of revision fixation and plate removal, were used as outcome indices of the reduction method effectiveness. The SWOT technique achieved satisfactory anatomical reduction in 27/40 patients when used alone. Other reduction methods were also used in 13/40 patients. No patient required revision fixation and three patients required late plate removal. SWOT can be used across the midface fracture pattern in conjunction with other methods or as a sole reduction method before miniplate fixation. PMID:24436763

  13. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    PubMed

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Comparison of the direct and indirect reduction techniques during the surgical management of posterior malleolar fractures.

    PubMed

    Shi, Hong-Fei; Xiong, Jin; Chen, Yi-Xin; Wang, Jun-Fei; Qiu, Xu-Sheng; Huang, Jie; Gui, Xue-Yang; Wen, Si-Yuan; Wang, Yin-He

    2017-03-14

    The optimal method for the reduction and fixation of posterior malleolar fracture (PMF) remains inconclusive. Currently, both of the indirect and direct reduction techniques are widely used. We aimed to compare the reduction quality and clinical outcome of posterior malleolar fracture managed with the direct reduction technique through posterolateral approach or the indirect reduction technique using ligamentotaxis. Patients with a PMF involving over 25% of the articular surface were recruited and assigned to the direct reduction (DR) group or the indirect reduction (IR) group. Following reduction and fixation of the fracture, the quality of fracture reduction was evaluated in post-operative CT images. Clinical and radiological follow-ups were performed at 6 weeks, 3 months, 6 months, 12 months, and then at 6 month-intervals postoperatively. Functional outcome (AOFAS score), ankle range of motion, and Visual Analog Scale (VAS) were evaluated at the last follow-up. Statistical differences were compared between the DR and IR groups considering the patient demographics, quality of fracture reduction, AOFAS score, and VAS. Totally 116 patients were included, wherein 64 cases were assigned to the DR group and 52 cases were assigned to the IR group. The quality of fracture reduction was significant higher in the DR group (P = 0.038). In the patients who completed a minimum of 12 months' follow-up, a median AOFAS score of 87 was recorded in the DR group, which was significantly higher than that recorded in the IR group (a median score of 80). The ankle range of motion was slightly better in the DR group, with the mean dorsiflexion restriction recorded to be 5.2° and 6.1° in the DR and IR group respectively (P = 0.331). Similar VAS score was observed in the two groups (P = 0.419). The direct reduction technique through a posterolateral approach provide better quality of fracture reduction and functional outcome in the management of PMF over 25% of articular surface, as compared with the indirect reduction technique using ligamentotaxis. NCT02801474 (retrospectively registered, June 2016, ClinicalTrails.gov).

  15. Posterolaterally Displaced and Flexion Type Supracondylar Fractures are Associated with a Higher Risk of Open Reduction

    PubMed Central

    Novais, Eduardo N.; Carry, Patrick M.; Mark, Bryan J.; Sayan, DE; Miller, Nancy H.

    2016-01-01

    Objective To identify factors predictive of the risk of conversion from closed to open reduction. Methods ICD-9 codes were used to identify completely displaced pediatric supracondylar humerus fractures that underwent planned closed reduction and percutaneous pinning. Clinical and radiographic variables were retrospectively collected. Results Compared to posterior extension fractures, flexion [Risk Ratio (RR): 34.1, 95% CI: 8.1 to 143.6, p<0.0001] and posterolateral extension [RR: 6.0, 95% CI: 1.3 to 27.5, p=0.0221] fractures were significantly more likely to undergo conversion from closed to open reduction. Conclusions The direction of displacement should be considered during the pre-operative evaluation of supracondylar fractures. PMID:27035497

  16. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction.

    PubMed

    Zeng, Canjun; Xing, Weirong; Wu, Zhanglin; Huang, Huajun; Huang, Wenhua

    2016-10-01

    Treatment of acetabular fractures remains one of the most challenging tasks that orthopaedic surgeons face. An accurate assessment of the injuries and preoperative planning are essential for an excellent reduction. The purpose of this study was to evaluate the feasibility, accuracy and effectiveness of performing 3D printing technology and computer-assisted virtual surgical procedures for preoperative planning in acetabular fractures. We hypothesised that more accurate preoperative planning using 3D printing models will reduce the operation time and significantly improve the outcome of acetabular fracture repair. Ten patients with acetabular fractures were recruited prospectively and examined by CT scanning. A 3-D model of each acetabular fracture was reconstructed with MIMICS14.0 software from the DICOM file of the CT data. Bone fragments were moved and rotated to simulate fracture reduction and restore the pelvic integrity with virtual fixation. The computer-assisted 3D image of the reduced acetabula was printed for surgery simulation and plate pre-bending. The postoperative CT scan was performed to compare the consistency of the preoperative planning with the surgical implants by 3D-superimposition in MIMICS14.0, and evaluated by Matta's method. Computer-based pre-operations were precisely mimicked and consistent with the actual operations in all cases. The pre-bent fixation plates had an anatomical shape specifically fit to the individual pelvis without further bending or adjustment at the time of surgery and fracture reductions were significantly improved. Seven out of 10 patients had a displacement of fracture reduction of less than 1mm; 3 cases had a displacement of fracture reduction between 1 and 2mm. The 3D printing technology combined with virtual surgery for acetabular fractures is feasible, accurate, and effective leading to improved patient-specific preoperative planning and outcome of real surgery. The results provide useful technical tips in planning pelvic surgeries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Analysis of patterns and treatment strategies for mandibular condyle fractures: review of 175 condyle fractures with review of literature.

    PubMed

    Reddy, N Viveka V; Reddy, P Bhaskar; Rajan, Ritesh; Ganti, Srinivas; Jhawar, D K; Potturi, Abhinand; Pradeep

    2013-09-01

    This study aims to evaluate incidence, patterns and epidemiology of mandibular condylar fractures (MCF) to propose a treatment strategy for managing MCF and analyze the factors which influence the outcome. One hundred and seventy-five MCF's were evaluated over a four year period and their pattern was recorded in terms of displacement, level of fracture, age of incidence and dental occlusion. Of the 2,718 facial bone fractures, MCF incidence was the third most common at 18.39 %. Of 175 MCF 58.8 % were unilateral and 41.12 % were bilateral. 67 % of bilateral fractures and 43.8 % of unilateral fractures were associated with midline symphysis and contralateral parasymphysis fractures respectively. Most of the MCF was seen in the age group of above 16 years and 50 % of them were at subcondylar level (below the neck of the condyle). Majority of MCF sustained due to inter personal violence were undisplaced (72.7 %) and contrary to this majority of MCF sustained during road traffic accident were displaced. 62.9 % of total fractures required open reduction and rigid fixation and 37.1 % were managed with closed reduction. 80 % of MCF managed with closed reduction were in the age group of below 16 years. From this study it can be concluded that the treatment algorithm proposed for managing MCF is reliable and easy to adopt. We observed that absolute indication for open reduction of MCF is inability to achieve satisfactory occlusion by closed method and absolute contraindication for open reduction is condylar head fracture irrespective of the age of the patient.

  18. Complex proximal humerus fractures: Hertel's criteria reliability to predict head necrosis.

    PubMed

    Campochiaro, G; Rebuzzi, M; Baudi, P; Catani, F

    2015-09-01

    The risk of post-traumatic humeral head avascular necrosis (AVN), regardless of the treatment, has a high reported incidence. In 2004, Hertel et al. stated that the most relevant predictors of ischemia after intracapsular fracture treated with osteosynthesis are the calcar length, medial hinge integrity and some specific fracture types. Based on Hertel's model, the purpose of this study is to evaluate both its reliability and weaknesses in our series of 267 fractures, assessing how the anatomical configuration of fracture, the quality of reduction and its maintenance were predictive of osteonecrosis development, and so to suggest a treatment choice algorithm. A retrospective study, level of evidence IV, was conducted to duly assess the radiographic features of 267 fractures treated from 2004 to 2010 following Hertel's criteria treated with open reduction and internal fixation by angular stability plates and screws. The average age was 65.2 years. The average follow-up was 28.3 ± 17.0 months. The percentage of AVN, the quality and maintenance of reduction obtained during surgery were evaluated. The AVN incidence was 3.7 %. No significant correlation with gender, age and fracture type was found. At the last follow-up X-ray, only 30 % presented all Hertel's good predictors in the AVN group, 4.7 % in the non-AVN group (p < 0.05). About quality of reduction in the AVN group, it was poor in 50 %; while in the non-AVN group, it was poor in 3.4 % (p < 0.05). Four patients with AVN were symptomatic, and three needed a second surgery. Hertel's criteria are important in the surgical planning, but they are not sufficient: an accurate evaluation of the calcar area fracture in three planes is required. All fractures involving calcar area should be studied with CT.

  19. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    PubMed

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has advantages of small trauma, fixed fixation, quick recovery, early postoperative functional exercise. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  20. Surgical treatment for pilon fracture of the ankle-open reduction and internal fixation.

    PubMed

    Chen, Y W; Huang, P J; Hsu, C Y; Kuo, C H; Cheng, Y M; Lin, S Y; Chen, L H; Chiang, H C

    1998-01-01

    From 1991 to 1994, 39 ankles of 38 patients underwent surgical open reduction and internal fixation for pilon fractures. These patients included 29 males and 9 females with an average age of 38.6 y/o (range 28 y/o-58 y/o). The follow up and evaluation period averaged 31.7 months (range 22Ms-44Ms), during which time a standing x-ray for arthrosis grading and functional scale was used for clinical evaluation. Complications included 1 case of infection, 1 case of loss reduction, 2 cases of partial skin necrosis and 2 cases of delayed union. Post-traumatic arthritis occurred in 23 ankles (59%) but only 4 ankles of grade 4 arthrosis resulted in poor functional scale and the overall satisfactory rate was 82%. It was found that anatomic reduction, rigid fixation and early motion exercise are important to successful treatment of ankle fractures. Regarding pilon fracture, specifically the severity of fracture pattern and delay of reduction are important problems to overcome to ensure successful results. Therefore, adequate surgical approach for entire view of ankle joint, reduction and fixation of fibula, sufficient bone graft for articular support, intraoperative x-ray check and postoperative immobilization are essential for the achievement of better clinical results.

  1. Reproducibility of three dimensional digital preoperative planning for the osteosynthesis of distal radius fractures.

    PubMed

    Yoshii, Yuichi; Kusakabe, Takuya; Akita, Kenichi; Tung, Wen Lin; Ishii, Tomoo

    2017-12-01

    A three-dimensional (3D) digital preoperative planning system for the osteosynthesis of distal radius fractures was developed for clinical practice. To assess the usefulness of the 3D planning for osteosynthesis, we evaluated the reproducibility of the reduction shapes and selected implants in the patients with distal radius fractures. Twenty wrists of 20 distal radius fracture patients who underwent osteosynthesis using volar locking plates were evaluated. The 3D preoperative planning was performed prior to each surgery. Four surgeons conducted the surgeries. The surgeons performed the reduction and the placement of the plate while comparing images between the preoperative plan and fluoroscopy. Preoperative planning and postoperative reductions were compared by measuring volar tilt and radial inclination of the 3D images. Intra-class correlation coefficients (ICCs) of the volar tilt and radial inclination were evaluated. For the implant choices, the ICCs for the screw lengths between the preoperative plan and the actual choices were evaluated. The ICCs were 0.644 (p < 0.01) and 0.625 (p < 0.01) for the volar tilt and radial inclination in the 3D measurements, respectively. The planned size of plate was used in all of the patients. The ICC for the screw length between preoperative planning and actual choice was 0.860 (p < 0.01). Good reproducibility for the reduction shape and excellent reproducibility for the implant choices were achieved using 3D preoperative planning for distal radius fracture. Three-dimensional digital planning was useful to visualize the reduction process and choose a proper implant for distal radius fractures. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2646-2651, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

    PubMed Central

    Hassan, Youssef G.; Joukhadar, Nabih I.

    2018-01-01

    Medial epicondyle entrapment after an acute fracture dislocation of the elbow is a common finding in the pediatric population, but a rare finding in adults. We present a case of an adult patient diagnosed with a traumatic fracture dislocation of the elbow joint with intra-articular entrapment of the medial epicondyle. After initial evaluation, closed reduction was done. Stability testing after reduction showed an unstable joint; thus, open reduction and internal fixation was decided. PMID:29666736

  3. An investigation of new metal framework design for metal ceramic restorations.

    PubMed

    O'Boyle, K H; Norling, B K; Cagna, D R; Phoenix, R D

    1997-09-01

    Metal ceramic restorations have been implicated in the discoloration of associated gingival tissues. Attempts to remedy this by altering the design of the metal frameworks for such restorations may lead to unacceptable decreases in fracture resistance. This study evaluated a new metal framework design for metal-ceramic restorations. Twenty artificial crowns were fabricated with various degrees of facial metal reduction; 0, 1, 2, and 3 mm. The study was conducted in two parts. The first part evaluated changes in light transmission into adjacent root tissue. A light box was fabricated so sample crowns could be illuminated on a mounted natural tooth. The root of the tooth remained outside the light box, and the light transmitted through the crowns into root tissue was measured with a light meter. The second part of the study evaluated changes in fracture strength. The sample crowns were subjected to a vertical load until fracture with use of an Instron machine at a crosshead speed of 1 mm per minute. The load at fracture was recorded. Results indicated a statistically significant increase in light transmission with 1 mm framework reduction or greater, and fracture strengths did not decrease with up to 1 mm of framework reduction. A 1 mm facial axial reduction of the metal framework may be indicated for anterior metal-ceramic restorations.

  4. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    PubMed

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  5. Mandible Fractures

    PubMed Central

    Pickrell, Brent B.; Serebrakian, Arman T.; Maricevich, Renata S.

    2017-01-01

    Mandible fractures account for a significant portion of maxillofacial injuries and the evaluation, diagnosis, and management of these fractures remain challenging despite improved imaging technology and fixation techniques. Understanding appropriate surgical management can prevent complications such as malocclusion, pain, and revision procedures. Depending on the type and location of the fractures, various open and closed surgical reduction techniques can be utilized. In this article, the authors review the diagnostic evaluation, treatment options, and common complications of mandible fractures. Special considerations are described for pediatric and atrophic mandibles. PMID:28496390

  6. Mandible Fractures.

    PubMed

    Pickrell, Brent B; Serebrakian, Arman T; Maricevich, Renata S

    2017-05-01

    Mandible fractures account for a significant portion of maxillofacial injuries and the evaluation, diagnosis, and management of these fractures remain challenging despite improved imaging technology and fixation techniques. Understanding appropriate surgical management can prevent complications such as malocclusion, pain, and revision procedures. Depending on the type and location of the fractures, various open and closed surgical reduction techniques can be utilized. In this article, the authors review the diagnostic evaluation, treatment options, and common complications of mandible fractures. Special considerations are described for pediatric and atrophic mandibles.

  7. Treatment of type II odontoid fracture with a novel technique

    PubMed Central

    Zhu, Ce; Wang, Lei; Liu, Hao; Song, Yueming; Liu, Limin; Li, Tao; Gong, Quan

    2017-01-01

    Abstract Surgical methods for type II odontoid fracture can be classified into 2 main groups: anterior or posterior approach. A more effective way to achieve bone fusion with the lowest possible surgical risk is needed. Therefore, the aim of our study was to describe and evaluate a novel technique, cable-dragged reduction/cantilever beam internal fixation for the treatment of type II odontoid fracture. This was a retrospective study enrolled 34 patients underwent posterior cable-dragged reduction/cantilever-beam internal fixation surgery. Medical records, rates of reduction, the location of the instrumentation and fracture healing during follow-up were analyzed. Once fracture healing was obtained, instrumentation was removed. Neck pain (scored using a visual analog scale [VAS]), neck stiffness, patient satisfaction, and neck disability index (NDI) were recorded before and after removing the instrumentation during follow-up. The mean duration of follow up was 22.8 ± 5.3 months. There was no iatrogenic damage to nerves or blood vessels. Radiographic evaluation showed complete reduction in the 20 patients with fracture displacement and satisfactory fracture healing in all 34 cases. Titanium cable breakage was observed in 4 patients after fracture healing. After removal of instrumentation, significant improvements were seen in neck-pain VAS score, neck stiffness, patient satisfaction, and NDI (all P < .01). Posterior cable-dragged reduction/cantilever-beam internal fixation was an optimal salvage maneuver to conventional surgical methods such as anterior screw fixation and C1–C2 screw-rod system. The operative difficulty and incidence of nerve and vascular injury were reduced. Its major disadvantage is the exposure and screw-setting at C3, which is left intact in traditional surgery, and it is suitable only for patients with intact C1 posterior arches. PMID:29095313

  8. [Manipulative reduction and external fixation with cardboard splint for the treatment of calcaneal fractures: a 60-case report].

    PubMed

    Hao, Bo-Chuan; Xie, Ke-Bo

    2014-07-01

    To investigate the therapeutic effects of manipulative reduction for calcaneal fractures. From January 2009 to June 2012, 53 cases (60 affected feet) of Sanders type I-IV calcaneal fractures were treated by manipulative reduction and external fixation with cardboard splint,including 45 males and 8 females with an average age of (33.5 +/- 1.54) years old ranging from 18 to 65. The course of disease ranged 0.5 h to 7 d. Before treatment the feet were swelling, ache and activity limitation in evidence, some feet were wide flat deformity, the cortical bone was broken in the imaging examination. All selected cases were evaluated using Creighton-Nebraska health foundation assessment scale for fractures of calcaneus. All cases were followed up at 12 months after treatment, 13 feet got excellent curative effect, 34 good, 11 moderate and 2 poor. Manipulative reduction for Sanders type I-IV calcaneal fractures could get excellent curative effect. Manipulative reduction for calcaneal fractures could avoid surgical trauma while assure high curative effects. Manipulative reduction is not only economical and easy therapy, but also can restore maximum function of the calcaneus with few complications and facilitate early rehabilitation of ankle and joint function.

  9. Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2016-03-01

    Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model. The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09 mm (translations) and of [Formula: see text] (rotations), maximum observed errors in the order of 0.12 mm (translations) and of [Formula: see text] (rotations), and a reduction repeatability of 0.02 mm and [Formula: see text]. The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality.

  10. Part II: arthroscopic treatment of tibial plateau fractures: intercondylar eminence avulsion fractures.

    PubMed

    Lubowitz, James H; Elson, Wylie S; Guttmann, Dan

    2005-01-01

    Arthroscopic reduction and internal fixation (ARIF) of tibial intercondylar eminence fractures is the emerging state-of-the-art. ARIF is recommended for displaced type III fractures and should be considered for all cases of displaced type II fractures. Fractures without displacement after closed reduction require careful evaluation to rule out meniscal entrapment. Subjective results of ARIF are uniformly excellent, despite reports of objective anteroposterior laxity. Early range-of-motion exercises are essential to prevent loss of extension. Repair using nonabsorbable suture fixation, when of adequate strength to allow early range-of-motion, has the advantages of eliminating the risks of comminution of the fracture fragment, posterior neurovascular injury, and need for hardware removal, compared with ARIF using screws.

  11. Internal fixation of complex fractures of the tarsal navicular with locking plates. A report of 10 cases.

    PubMed

    Cronier, P; Frin, J-M; Steiger, V; Bigorre, N; Talha, A

    2013-06-01

    Tarsal navicular fractures are rare and treatment of comminuted fractures is especially difficult. Since 2007, the authors have had access to 3D reconstruction from CT scan images and specific locking plates, and they decided to evaluate whether these elements improved management of these severe cases. Between 2007 and 2011, 10 comminuted tarsal navicular fractures were treated in a prospective study. All of the fractures were evaluated by 3D reconstruction from CT scan images, with suppression of the posterior tarsal bones. The surgical approach was chosen according to the type of lesion. Reduction was achieved with a mini-distractor when necessary, and stabilized by AO locking plate fixation (Synthes™). Patient follow-up included a clinical and radiological evaluation (Maryland Foot score, AOFAS score). Eight patients underwent postoperative CT scan. All patients were followed up after a mean 20.5 months. Union was obtained in all patients and arthrodesis was not necessary in any of them. The mean Maryland Foot score was 92.8/100, and the AOFAS score 90.6/100. One patient with an associated comminuted calcaneal fracture had minimal sequella from a compartment syndrome of the foot. The authors did not find any series in the literature that reported evaluating tarsal navicular fractures by 3D reconstruction from CT scan images. The images obtained after suppression of the posterior tarsal bones systematically showed a lateral plantar fragment attached to the plantar calcaneonavicular ligament, which is essential for stability, and which helped determine the reduction technique. Locking plate fixation of these fractures has never been reported. Comminuted fractures of the tarsal navicular were successfully treated with specific imaging techniques in particular 3D reconstructions of CT scan images to choose the surgical approach and the reduction technique. Locking plate fixation of the navicular seems to be a satisfactory solution for the treatment of these particularly difficult fractures. Level IV. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  12. Treatment of Mandibular Condyle Fractures Using a Modified Transparotid Approach via the Parotid Mini-Incision: Experience with 31 Cases

    PubMed Central

    Shi, Jun; Yuan, Hao; Xu, Bing

    2013-01-01

    Surgery for mandibular condyle fractures must allow direct vision of the fracture, reduce surgical trauma and achieve reduction and fixation while avoiding facial nerve injury. This prospective study was conducted to introduce a new surgical approach for open reduction and internal fixation of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision, and surgical outcomes were evaluated. The modified transparotid approach via the parotid mini-incision was applied and rigid internal fixation using a small titanium plate was carried out for 36 mandibular condyle fractures in 31 cases. Postoperative follow-up of patients ranged from 3 to 26 months; in the first 3 months after surgery, outcomes for all patients were analyzed by evaluating the degree of mouth opening, occlusal relationship, facial nerve function and results of imaging studies. The occlusal relationships were excellent in all patients and none had symptoms of intraoperative ipsilateral facial nerve injury. The mean degree of mouth opening was 4.0 (maximum 4.8 cm, minimum 3.0 cm). No mandibular deviations were noted in any patient during mouth opening. CT showed complete anatomical reduction of the mandibular condyle fracture in all patients. The modified transparotid approach via the smaller, easily concealed parotid mini-incision is minimally invasive and achieves anatomical reduction and rigid internal fixation with a simplified procedure that directly exposes the fracture site. Study results showed that this procedure is safe and feasible for treating mandibular condyle fracture, and offers a short operative path, protection of the facial nerve and satisfactory aesthetic outcomes. PMID:24386221

  13. [Case-control study on bone setting manipulation for the treatment of over degree II supination-eversion fractures of ankle joint].

    PubMed

    Qi, Yue-Feng; Chen, Fa-Lin; Bao, Shu-Ren; Li, Cheng-Huan; Zhao, Xing-Wei; Liu, Shi-Ming; Chen, Wen-Xue; Li, Ye; Wang, Peng

    2012-08-01

    To explore therapeutic effects of bone setting manipulation for the treatment of over degree II supination-eversion fractures of ankle,and analyze manipulative reduction mechanism. From 2005 to 2008, 95 patients with over degree II supination-eversion fractures of ankle were treated respectively by manipulation and operation. There were 43 cases [11 males and 32 females with an average age of (44.95 +/- 12.65) years] in manipulation group, and 2 cases were degree II, 11 cases were degree III, and 30 cases were degree IV. There were 52 cases [21 males and 31 females with an average age of (39.96 +/- 13.28) years] in operative group,and 6 cases were degree II, 18 cases were degree III, and 28 cases were degree IV. Bone setting manipulation and hard splint external fixation were applied to manipulative group. Operative reduction internal fixation was performed in operative group. X-ray was used to evaluate reduction of fracture before and after treatment, 2 months after treatment. Ankle joint function was evaluated according to Olerud-Molander scoring system after 6 months treatment. All patients were followed up with good reduction. Three cases occurred wound complication in operative group, but not in manipulative group. In manipulation group, 19 cases got excellent results, 20 cases good and 4 cases fair; while in operative group, 30 cases got excellent results, 20 cases good and 2 cases poor. There were no significant differences in fracture reduction and ankle joint function recovery between two groups (P > 0.05). Efficacy of operative treatment was better than that of manipulative treatment at degree IV fracture (P < 0.05). Bone setting manipulation is a good method for treating supination-eversion ankle joint fractures, which has advantages of simple and safe operation, reliable efficacy. For ankle join fracture at degree IV, manipulative reduction should be adopted earlier, and operative treatment also necessary

  14. [Roof folding and rotary pushing for the treatment of back to back fractures of distal radius and ulna in children].

    PubMed

    Xu, Ping; Dong, Xiao-jun; Lu, Zhou-tong; Wang, Gongjun; Zhang, Han-qing; Chen, Xuan-ning; Li, Dong

    2015-09-01

    To evaluate the technique and the clinical effect of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back". From January 2012 to February 2014,38 children with distal radius and ulna fracture of "back to back" were treated by using the technique of folding roof and rotary pushing to reset and splint fixation including 23 males and 15 females with an average age of 9.5 years old ranging from 6 to 14 years old. Injury time was from 45 min to 3 days (averaged 1.3 days). All cases was unilateral closed fracture without symptoms of nerve injury occurred. The wrist joint anteroposterior and lateral radiographs showed double fracture of radius and ulna, and the broken end of radius was typical "back to back" displacement. The quality of reduction was assessed according to Dienst recommendation on the combination of Aro measurement, and the therapeutic effect was evaluated using standard of Anderson function. All patients were followed up from 3 to 13 months with an average of 6 months. There were no iatrogenic nerve injury. Thirty cases were treated successfully for the first time, 8 cases were again reset successfully; 28 cases were anatomical reduction, 7 cases were near anatomic reduction, 3 cases were functional reduction. At the second day 7 cases with hand and finger swelling appeared in multiple reset patients. Quality results of reduction were excellent in 33 cases, good in 5 cases. According to the standard of Anderson function evaluation, 35 cases were excellent, 3 cases were good. All fractures were healed with of deformity of wrist. Using the technique of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back" is very successful, the patient's limb function recovered well, the whole operation process is simple.

  15. [Utility of nickel-titanium shape memory alloys of vertebral body reduction fixator with assisted distraction bar].

    PubMed

    Man, Yi; Zheng, Yue-huan; Cao, Peng; Chen, Bo; Zheng, Tao; Sun, Chang-hui; Lu, Jiong

    2011-06-07

    To test the nickel-titanium (Ni-Ti) shape memory alloys of vertebral body reduction fixator with assisted distraction bar for the treatment of traumatic and osteoporotic vertebral body fracture. A Ni-Ti shape memory alloys of vertebral body reduction fixator with assisted distraction bar was implanted into the compressed fracture specimens through vertebral pedicle with the radiographic monitoring to reduce the collapsed endplate as well as distract the compressed vertebral fracture. Radiographic film and computed tomographic reconstruction technique were employed to evaluate the effects of reduction and distraction. A biomechanic test machine was used to measure the fatigue and the stability of deformation of fixation segments. Relying on the effect of temperature shape memory, such an assembly could basically reduce the collapsed endplate as well as distract the compressed vertebral fracture. And when unsatisfied results of reduction and distraction occurred, its super flexibility could provide additional distraction strength. A Ni-Ti shape memory alloys of vertebral body reduction fixator with assisted distraction bar may provide effective endplate reduction, restore the vertebral height and the immediate biomechanic spinal stability. So the above assembly is indicated for the treatment of traumatic and osteoporotic vertebral body fracture.

  16. Open reduction of nasal bone fractures through an intercartilaginous incision.

    PubMed

    Kim, Ji Heui; Lee, Jun Ho; Hong, Seok Min; Park, Chan Hum

    2013-01-01

    Open reduction through an intercartilaginous incision was useful for treating delayed-diagnosed nasal bone fractures because it resulted in a successful outcome with minimal complications. Nasal bone fractures are generally managed with closed reduction, which is usually inadequate and results in airway obstruction with a delayed diagnosis of nasal bone fracture when bone healing and fibrotic adhesions around the bone fragment have progressed. This study investigated the surgical outcome of open reduction through an intercartilaginous incision for delayed-diagnosis nasal bone fractures. The study enrolled 18 patients who underwent open reduction through an intercartilaginous incision to correct delayed-diagnosis nasal bone fractures. Three independent otorhinolaryngologists evaluated the outcomes 4-35 months (average 12.7 months) postoperatively as excellent, fair or poor. The time from injury to surgery was 11-39 days (20-39 days in adults and 11-30 days in children). The 18 cases included 16 primary repairs and two revisions. A Kirschner wire was inserted in six (33.3%) patients who had unstable reduced nasal bones. Postoperatively, l5 (83%) patients had excellent results, two (11%) had fair, and one (6%) had a poor outcome. No patient experienced any complication.

  17. Analysis of the Postoperative Displacement of Trochanteric Fractures on Lateral View Radiographs.

    PubMed

    Furui, Atsuo; Terada, Nobuki

    2017-08-01

    Achieving sufficient support of the anterior cortex of the femoral neck is a fundamental goal of the reduction of trochanteric fractures. However, anterior-cortex support is often lost after the fracture reduction. Our aim was to analyze factors contributing to the postoperative displacement of an acceptably reduced trochanteric fracture. The cases of 40 patients with a post-reduction Ikuta subtype N fracture alignment were reviewed. All fractures were fixed with 135° free-sliding plates. On postoperative day 14, patients were classified into two groups: those with retention of the Ikuta subtype N alignment, and those with progression to Ikuta subtype P alignment. The clinical and radiological factors were evaluated between the groups. In addition, to define one of the factors, i.e., the postoperative rotational displacement between the proximal and distal fragments, the relationship between radiographic findings and computed tomography image measurements was assessed in 15 of the 40 patients. Angulation at the fracture site on lateral view radiographs was defined as postoperative rotational displacement, and unstable trochanteric fractures and postoperative rotational displacement were identified as significant risk factors for the postoperative displacement. Therefore, cautious and careful follow-up is warranted for patients with unstable trochanteric fractures or fractures having rotational displacement.

  18. Comparative study of the prognosis of an extracorporeal reduction and a closed treatment in mandibular condyle head and/or neck fractures.

    PubMed

    Park, Jung-Min; Jang, Yong-Wook; Kim, Seong-Gon; Park, Young-Wook; Rotaru, Horatiu; Baciut, Grigore; Hurubeanu, Lucia

    2010-12-01

    The objective of this study was a comparison of the prognosis between an extracorporeal reduction technique and closed treatment of a mandibular condyle fracture. The relationship between condylar resorption and several clinical variables was also studied. Seventy-one patients who had a mandibular condyle fracture took part in this study. Thirty-five patients (female: 7, male: 28, age: 30.46 ± 14.27 years) were treated by extracorporeal reduction, and 36 patients (male: 24, female: 12, age: 24.28 ± 9.99 years) were treated using a closed treatment. The presence of complications such as condylar resorption, malocclusion, nerve disorder, and disc displacement was evaluated with panoramic radiographs and clinical examinations 12 months after treatment. The relationships between the complications and other clinical variables were evaluated statistically. The anatomic site and fracture type were closely related to condyle resorption in the bivariate analysis. Condylar head fractures showed significantly higher condyle resorption than condylar neck fractures (P = .023). A complex or compound fracture showed significantly higher condyle resorption compared with a simple fracture (P = .006). Patients who had a complex/compound fracture were 34.366 times more likely to have condyle resorption compared with those who had a simple fracture (P = .002). The patient's age and treatment method were also significant predictors for condyle resorption. Fracture type was the strongest predictor of condylar resorption. Because treatment method and patient age were also related to the prognosis, the optimal treatment for mandibular condylar head and/or neck fractures should be individualized according to the patient's condition. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Preoperative trajectory planning for closed reduction of long-bone diaphyseal fracture using a computer-assisted reduction system.

    PubMed

    Du, Hailong; Hu, Lei; Li, Changsheng; He, Chunqing; Zhang, Lihai; Tang, Peifu

    2015-03-01

    Balancing reduction accuracy with soft-tissue preservation is a challenge in orthopaedics. Computer-assisted orthopaedic surgery (CAOS) can improve accuracy and reduce radiation exposure. However, previous reports have not summarized the fracture patterns to which CAOS has been applied. We used a CAOS system and a stereolithography model to define a new fracture classification. Twenty reduction tests were performed to evaluate the effectiveness of preoperative trajectory planning. Twenty tests ran automatically and smoothly. Only three slight scratches occurred. Seventy-six path points represented displacement deviations of < 2 mm (average < 1 mm) and angulation deviation of < 1.5°. Because of the strength of muscles, mechanical sensors are used to prevent iatrogenic soft-tissue injury. Secondary fractures are prevented mainly through preoperative trajectory planning. Based on our data, a 1 mm gap between the edges of fractures spikes is sufficient to avoid emergency braking from spike interference. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    PubMed

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted tibial pilon fracture reliably healed and restored acceptable function in this highly selective patient group. Ring external fixation may be a useful adjunct to internal fixation, and this concept should be further studied. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  1. A comprehensive study on maxillofacial trauma conducted in Yamunanagar, India

    PubMed Central

    Bali, Rishi; Sharma, Parveen; Garg, Amandeep; Dhillon, Guneet

    2013-01-01

    Abstract: Background: The Department of Oral and Maxillofacial Surgery, D.A.V [C] Dental College and Hospital, Yamuna Nagar, Haryana, India conducted a study on patients with maxillofacial fractures in a time span of seven years (2003-2010). The purpose of this study was to evaluate their aetiology, incidence, patterns and different modalities employed for management. Methods: In this study, 740 patients with 1054 fractures were evaluated clinically and radiographically, based on which closed reduction and open reduction was undertaken. Review of patient records included: Age, sex, time, mechanism and etiology of injury, history of bleeding, unconsciousness and prior first aid, type of vehicle and use of preventive measures, type of fracture and treatment modalities. Results: Road traffic accidents accounted for highest number of fractures predominantly occurring in the age group of 21-30 years (38.3%)1,2. Males incurred more fractures with a male female ratio of 4.2: 1.Mandible was the most commonly fractured bone with parasymphysis being the commonest affected site.76.66% patients had associated head injury and 15.68 % had history of unconsciousness. Open reduction and internal fixation was the preferred modality for mandible whereas the mid face fractures were treated more often by closed methods. Conclusions: Injuries occurred more commonly in 20 – 40 age range with road traffic accident being the major etiological factor. Majority of the patients were driving two wheelers and most were under the effect of alcohol. Most of the injuries occurred during night and road traffic accidents (71.89%) were found to be the major etiological factor. Out of 532 road traffic accidents, 490 patients (66.2%) were on two wheelers, among whom 49(10%) were wearing helmet. In the mandible, fractures occurred most commonly in the parasymphyseal region (224, 30.2%), and out of the 314 fractures of the middle third showed, 155 (49.4%) ZMC. OPG was the most commonly advised X-ray. With regard to treatment modalities, 36.8% of all the mandibular fractures (740) were treated by closed reduction, 62.6% were treated using open reduction and 0.5% was under observation only. PMID:23594725

  2. High degree of patient satisfaction after percutaneous treatment of lateral tibia plateau fractures.

    PubMed

    Elsøe, Rasmus; Larsen, Peter; Rasmussen, Sten; Hansen, Hans Ager; Eriksen, Christian Berre

    2016-01-01

    The outcomes and complications following surgical treatment of tibial plateau fractures have been widely reported. The objective of this study was to evaluate the quality of life (QoL), functional and radiological outcomes after lateral tibial plateau fractures, Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 41-B2 and B3, treated with minimally invasive bone tamp reduction, allograft and percutaneous screw fixation. This study was a cross-sectional study and a retrospective review and clinical evaluation of patients treated with minimally invasive bone tamp reduction, allograft and percutaneous screw fixation after lateral tibial plateau fractures between 2005 and 2010. The patients completed a clinical examination, Knee Injury and Osteoarthritis Outcome Score (KOOS) and a questionnaire for evaluation of QoL (Eq5D-5L). A total of 28 patients agreed to participate (71%). The mean follow-up time was 2.5 years. Maintained anatomical joint reduction and alignment was achieved in 23 cases. The mean Eq5D-5L index was 0.850. The mean KOOS scores were: pain = 79.9, ADL = 80.8, symptoms = 73.0, QoL = 61.3 and sport = 54.4. Compared with Eq5D-5L reference norms, patients did not report significantly lower scores. Compared with a KOOS reference group, patients reported significantly lower KOOS scores in three subscales. Tibial plateau fractures AO type 41-B2 and 41-B3 treated with minimally invasive bone tamp reduction, allograft and percutaneous screw fixation showed a high rate of anatomical reduction (82%), a low rate of complications (3.5%) and a high level of satisfactory patient-reported QoL. none. not relevant.

  3. Intra-operative 3D imaging system for robot-assisted fracture manipulation.

    PubMed

    Dagnino, G; Georgilas, I; Tarassoli, P; Atkins, R; Dogramadzi, S

    2015-01-01

    Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and lower infection risk. However, deducing intra-operatively the desired reduction position is quite challenging due to the currently available technology. The 2D nature of this technology (i.e. the image intensifier) doesn't provide enough information to the surgeon regarding the fracture alignment and rotation, which is actually a three-dimensional problem. This paper describes the design and development of a 3D imaging system for the intra-operative virtual reduction of joint fractures. The proposed imaging system is able to receive and segment CT scan data of the fracture, to generate the 3D models of the bone fragments, and display them on a GUI. A commercial optical tracker was included into the system to track the actual pose of the bone fragments in the physical space, and generate the corresponding pose relations in the virtual environment of the imaging system. The surgeon virtually reduces the fracture in the 3D virtual environment, and a robotic manipulator connected to the fracture through an orthopedic pin executes the physical reductions accordingly. The system is here evaluated through fracture reduction experiments, demonstrating a reduction accuracy of 1.04 ± 0.69 mm (translational RMSE) and 0.89 ± 0.71 ° (rotational RMSE).

  4. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients].

    PubMed

    Liu, Yin-Wen; Kuang, Yong; Gu, Xin-Feng; Zheng, Yu-Xin; Li, Zhi-Qiang; Wei, Xiao-En; Zhang, Ming-Cai; Zhan, Hong-Sheng; Shi, Yin-yu

    2013-03-01

    To evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures. From March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated. The mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair. Treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue injury, less blood loss, reliable fixation, which is effective method in treating proximal and distal tibial fractures and corresponds with the standpoint of biological fixation.

  5. Minimally invasive clamp-assisted reduction and cephalomedullary nailing without cerclage cables for subtrochanteric femur fractures in the elderly: Surgical technique and results.

    PubMed

    Mingo-Robinet, Juan; Torres-Torres, Miguel; Moreno-Barrero, María; Alonso, Juan Antonio; García-González, Sara

    2015-01-01

    The treatment of subtrochanteric fractures in the elderly remains technically challenging, due to instability and osteoporosis, with high reoperation rates. Even if intramedullary nailing is the most reliable treatment, reduction is difficult and cerclage wiring remains controversial. The purpose of this study was to evaluate 26 consecutive subtrochanteric fractures in elderly patients treated with a minimally invasive clamp-assisted reduction and cephalomedullary nailing without cerclage wiring. A retrospective analysis was conducted between January 2010 and September 2013. Data obtained from the medical records included patient's age, sex, classification of the fracture, the quality of reduction after surgery, and the presence of postoperative complications, especially fracture displacement and delayed union or nonunion. Twenty-six patients had adequate radiographic and clinical follow-up. Mean age was 84.4 (range 75-96) years. The mean duration of follow-up was 7.6 months (6-14 months). Mean surgical time was 74.42 min (range 45-115 min). Twenty-four (92.3%) showed acceptable varus/valgus alignment, and no sagittal plane malunions were noted. The tip-apex distance was <25 mm in all cases. Distraction at the fracture was <10mm in 21 fractures. Three patients had limb length discrepancy of 1cm. All fractures healed uneventfully. Reducing the fracture before nailing is mandatory to achieve good results. Minimally invasive clamp reduction without cerclage wires, even if challenging, has proven to be a safe, reproducible, and effective surgical technique, with at least the same results as other series. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Evaluation with stabilometric platform of balance disorders in osteoporosis patients. A proposal for a diagnostic protocol.

    PubMed

    Cultrera, Pina; Pratelli, Elisa; Petrai, Veronica; Postiglione, Marco; Zambelan, Giulia; Pasquetti, Pietro

    2010-05-01

    Osteoporosis is a systemic disease with reduced bone mass and qualitative alterations of the bone, associated to increased risk of fracture. Pathogenesis of osteoporosis fractures is multifactorial. Main risk factor is falls (except for vertebral fragility fractures which occurs often in absence of trauma). Aging by itself produces physiological changes: muscular hypotrophy with asthenia, deficit of visus and hearing together with associated pathologies and multi-drug therapies. In osteoporosis patients with vertebral fractures posture change occurs which reduces balance. After clinical postural evaluation it is possible to carry out instrumental evaluation of posture with computerized methods such as stabilometry, baropodometry, dynanometry and gait analysis. Examination carried out with use of stabilometric computerized platform allows stabilometric (body sway assessment) as well as posturometric examination (center of pressure assessment during quiet standing). Fundamental parameters obtained are: position of the body center of gravity, area and shape of sway density curve and velocity variables. Protocol of evaluation includes assessment of examination in standard condition and in condition of temporary sensorial deprivation (to investigate the influence of various afferent systems on the maintenance of posture and balance). Accurate evaluation of postural control in osteoporosis patients constitutes a fundamental tool in fracture risk evaluation due to fall and in identification and correction of modifiable factors responsible for balance defect. This approach, together with adequate drug therapy, may lead to significant reduction of fractures in osteoporosis patients with subsequent reduction of hospitalization and residual consequent disabilities.

  7. Reconstruction of the pelvic brim and its role in the reduction accuracy of displaced T-shaped acetabular fracture.

    PubMed

    Harnroongroj, T; Asavamongkolkul, A; Chareancholvanich, K

    2000-05-01

    Open reduction of the displaced T-shaped acetabular fracture has a problem of accuracy of the fracture reduction. This study was carried out to demonstrate that the reconstruction of the pelvic brim by approaching the pubo-acetabular fragment plays a role in the accuracy of the reduction of displaced T-shaped acetabular fractures. From 1975 to 1990, a retrospective study was carried out of 22 patients who sustained a displaced T-shaped acetabular fracture. The patients were operated on by open reduction and internal fixation of the ischio-acetabular fragment to the posterior column without restoration of the pelvic brim. Radiographs of the pelvis were reviewed. The result showed that there was displacement of the pubo-acetabular fragment including the medial wall in all cases. As the result of this study, a prospective study between 1990 and 1997 was carried out of 15 patients who sustained displaced T-shaped acetabular fractures including 3 cases with medial displacement of the femoral head. The pubo-acetabular fragment was anatomically reduced and fixed to the anterior column of the acetabulumn as the first approach to restore a disrupted pelvic brim. There, patterns of the acetabular fracture were subsequently re-evaluated especially the ischio-acetabular fragment including the position of the femoral head by using an intraoperative portable X-ray technique. The stability of the hip joint was assessed by hip flexion. The intraoperative radiograph appearances of the ischio-acetabular fragment were visually confirmed by a second surgical exposure. The results showed that the intraoperative radiographs gave spontaneous reduction of the ischio-acetabular fragment in all patients except one. There was a reduction of the displaced femoral head into the hip socket in the three patients. The hip joints were stable in all patients. The second surgical exposure showed that there was good spontaneous reduction of the ischio-acetabular fragment to the posterior column by ligamentotaxis in 14 patients. Therefore, it is not necessary to address the ischio-acetabular fragment. In the exceptional case, the ischio-acetabular fragment was displaced as a free bone which could not be reduced by ligamentotaxis. However, reduction and internal fixation of the ischio-acetabular fragment to the posterior column for complete re-application of the hip joint onto the pelvic ring of this case was facilitated. Postoperative 2 year and 5 year follow-up showed that the fracture had healed without heterotrophic ossification or premature osteoarthrosis of the hip joint. The exceptional case had a broken plate at the anterior column of the acetabulum. Hip function was evaluated clinically using Merle D' Aubigne's hip score. All patients had a "very good score". The study showed that reconstruction of the pelvic brim by anatomical reduction and fixation of the pubo-acetabular fragment to the anterior column plays an important role in the accuracy of fracture reduction of a displaced T-shaped acetabular fracture.

  8. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    PubMed

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  9. The posterior two-portal approach for reconstruction of scapula fractures: results of 39 patients.

    PubMed

    Pizanis, A; Tosounidis, G; Braun, C; Pohlemann, T; Wirbel, R J

    2013-11-01

    The purpose of this study was to describe the so-called posterior two-portal approach to the scapula in detail and to investigate the clinical outcome of patients with displaced glenoid and scapular neck fractures who were surgically treated using this approach. From February 1992 to August 2008, 39 patients (30 men and nine women; mean age: 53 years) with scapular fractures underwent surgical fixation at our institution. Thirty-three patients had glenoid fractures and six had unstable scapular neck fractures. All patients were treated via the two-portal approach. The reduction was evaluated radiographically, and the clinical results were analysed using the Constant score. The mean follow-up period was 78 months (range: 6-168). In 24 of the 33 glenoid fractures, the reduction was anatomical. The mean Constant score was 82.3 (range: 35-100) points. In one case, an early postoperative wound infection was cured by local revision, and one patient developed posttraumatic osteoarthritis of the acromioclavicular joint after 2 years. Only one patient developed specific glenohumeral degeneration after non-anatomical reduction. The posterior two-portal approach allows for a good visualisation of the posterior scapular neck and the glenoid area, facilitating the reduction and safe internal fixation of dislocated scapular neck and glenoid fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Isolated displaced non-union of a triquetral body fracture: a case report.

    PubMed

    Rasoli, Sonia; Ricks, Matthew; Packer, Greg

    2012-02-10

    Fractures of the body of the triquetral bone are the second most common carpal fractures, and these fractures can be missed on plain X-ray. Although non-union of triquetral body fractures is very rare, such cases are associated with considerable morbidity and reduction in functional activity. We report the case of a 29-year-old Caucasian British man who sustained an isolated displaced triquetral body fracture that resulted in non-union, who was treated surgically. We describe an original operative management for this debilitating injury. An open reduction and internal fixation using double headed compression screws was performed, without bone grafting, and with early immobilization of the wrist. We propose this novel approach and advocate early clinical suspicion of triquetral body fractures in patients with a history of fall on an outstretched hand and ulnar sided wrist pain. We recommend evaluation using computed tomography or magnetic resonance imaging scanning.

  11. Internal fixators: a safe option for managing distal femur fractures?

    PubMed Central

    Batista, Bruno Bellaguarda; Salim, Rodrigo; Paccola, Cleber Antonio Jansen; Kfuri, Mauricio

    2014-01-01

    OBJECTIVE: Evaluate safety and reliability of internal fixator for the treatment of intra-articular and periarticular distal femur fractures. METHODS: Retrospective data evaluation of 28 patients with 29 fractures fixed with internal fixator was performed. There was a predominance of male patients (53.5%), with 52% of open wound fractures, 76% of AO33C type fractures, and a mean follow up of 21.3 months. Time of fracture healing, mechanical axis deviation, rate of infection and postoperative complications were registered. RESULTS: Healing rate was 93% in this sample, with an average time of 5.5 months. Twenty-seven percent of patients ended up with mechanical axis deviation, mostly resulting from poor primary intra-operative reduction. There were two cases of implant loosening; two implant breakage, and three patients presented stiff knee. No case of infection was observed. Healing rate in this study was comparable with current literature; there was a high degree of angular deviation, especially in the coronal plane. CONCLUSION: Internal fixators are a breakthrough in the treatment of knee fractures, but its use does not preclude application of principles of anatomical articular reduction and mechanical axis restoration. Level of Evidence II, Retrospective Study. PMID:25061424

  12. Volar plate fixation failure for volar shearing distal radius fractures with small lunate facet fragments.

    PubMed

    Beck, John D; Harness, Neil G; Spencer, Hillard T

    2014-04-01

    To determine the percentage of AO B3 distal radius fractures that lose reduction after operative fixation and to see whether fracture morphology, patient factors, or fixation methods predict failure. We hypothesized that initial fracture displacement, amount of lunate facet available for fixation, plate position, and screw fixation would be significant risk factors for loss of reduction. A prospective, observational review was conducted of 51 patients (52 fractures) with AO B3 (volar shearing) distal radius fractures treated operatively between January 2007 and June 2012. We reviewed a prospective distal radius registry to determine demographic data, medical comorbidities, and physical examination findings. Radiographs were evaluated for AO classification, loss of reduction, length of volar cortex available for fixation, and adequacy of stabilization of the lunate facet fragment with a volar plate. Preoperative data were compared between patients who maintained radiographic alignment and those with loss of reduction. A multivariate logistic regression analysis was completed to determine significant predictors of loss of reduction. Volar shearing fractures with separate scaphoid and lunate facet fragments (AO B3.3), preoperative lunate subsidence distance, and length of volar cortex available for fixation were significant predictors for loss of reduction; the latter was significant in multivariate analysis. Plate position and number of screws used to stabilize the lunate facet were not statistically different between groups. Patients with AO B3.3 fractures with less than 15 mm of lunate facet available for fixation, or greater than 5 mm of initial lunate subsidence, are at risk for failure even if a volar plate is properly placed. In these cases, we recommend additional fixation to maintain reduction of the small volar lunate facet fracture fragments in the form of plate extensions, pins, wires, suture, wire forms, or mini screws. Therapeutic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study

    PubMed Central

    Bali, Rishi K.; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-01-01

    Aims: The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. Materials and Methods: This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Results: Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Conclusions: Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required. PMID:24665170

  14. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

    PubMed

    Bali, Rishi K; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-07-01

    The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required.

  15. Ultralow-dose computed tomography imaging for surgery of midfacial and orbital fractures using ASIR and MBIR.

    PubMed

    Widmann, G; Dalla Torre, D; Hoermann, R; Schullian, P; Gassner, E M; Bale, R; Puelacher, W

    2015-04-01

    The influence of dose reductions on diagnostic quality using a series of high-resolution ultralow-dose computed tomography (CT) scans for computer-assisted planning and surgery including the most recent iterative reconstruction algorithms was evaluated and compared with the fracture detectability of a standard cranial emergency protocol. A human cadaver head including the mandible was artificially prepared with midfacial and orbital fractures and scanned using a 64-multislice CT scanner. The CT dose index volume (CTDIvol) and effective doses were calculated using application software. Noise was evaluated as the standard deviation in Hounsfield units within an identical region of interest in the posterior fossa. Diagnostic quality was assessed by consensus reading of a craniomaxillofacial surgeon and radiologist. Compared with the emergency protocol at CTDIvol 35.3 mGy and effective dose 3.6 mSv, low-dose protocols down to CTDIvol 1.0 mGy and 0.1 mSv (97% dose reduction) may be sufficient for the diagnosis of dislocated craniofacial fractures. Non-dislocated fractures may be detected at CTDIvol 2.6 mGy and 0.3 mSv (93% dose reduction). Adaptive statistical iterative reconstruction (ASIR) 50 and 100 reduced average noise by 30% and 56%, and model-based iterative reconstruction (MBIR) by 93%. However, the detection rate of fractures could not be improved due to smoothing effects. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  16. Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children.

    PubMed

    Rizk, Ahmed Shawkat

    2015-06-01

    Supracondylar humeral fractures are one of the most common skeletal injuries in children. In cases of displacement and instability, the standard procedure is early closed reduction and percutaneous Kirschner wire fixation. However, between 10 and 20 % of patients present late. According to the literature, patients with neglected fractures are those patients who presented for treatment after 14 days of injury. The delay is either due to lack of medical facilities or social and financial constraints. The neglected cases are often closed injuries with no vascular compromise. However, the elbow may still be tense and swollen with abrasions or crusts. In neglected cases, especially after early appearance of callus, there is no place for closed reduction and percutaneous pinning. Traditionally, distal humeral fractures have been managed with surgical approaches that disrupt the extensor mechanism with less satisfactory functional outcome due to triceps weakness and elbow stiffness. The aim of this study is to evaluate the outcome of delayed open reduction using the triceps-sparing approach and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in children. This prospective study included 15 children who had neglected displaced supracondylar and distal humeral fractures. All patients were completely evaluated clinically and radiologically before intervention, after surgery and during the follow-up. The follow-up period ranged from 8 to 49 months, with a mean period of 17 months. Functional outcome was evaluated according to the Mayo Elbow Performance Index (MEPI) and Mark functional criteria. All fractures united in a mean duration of 7.2 weeks (range 5-10 weeks) with no secondary displacement or mal-union. Excellent results were found at the last follow-up in 13 of the 15 patients studied (86.66 %), while good results were found in two patients (13.33 %) according to the MEPI scale. According to the Mark functional criteria, there was one patient with a fair result (6.66 %). The results were very satisfactory if compared with traditional operative techniques, with many advantages including anatomical reduction and fixation of the fractures, avoidance of ulnar nerve injury, preservation of the extensor mechanism, decrease in incidence of myositis ossificans around the elbow and decrease in post-operative stiffness. IV.

  17. Minimizing complications associated with coronal approach by application of various modifications in surgical technique for treating facial trauma: A prospective study.

    PubMed

    Kumar, V Santosh; Rao, N Koteswara; Mohan, Kodali Rama; Krishna, Leela; Prasad, B Srinivasa; Ranganadh, N; Lakshmi, Vijaya

    2016-01-01

    Coronal incision is a popular and versatile surgical approach to the anterior cranial vault and upper and middle third facial skeleton. The flap itself permits widespread exposure of the fractures in this region. The bicoronal flap was first described by Hartley and Kenyon (neurosurgeons) to gain access to the anterior cranium in 1907. It extension as an access flap to the upper and lateral aspect of the face was pioneered by Tessier (1971). Esthetically, it is pleasing as the surgical scar is hidden within the hair. To evaluate the versatility of coronal incision using various modifications advocated in incision, exposure to fractured site, and closure of flap in treating the upper and middle third facial fractures. A total of ten patients diagnosed with upper and middle third facial fractures requiring open reduction and internal fixation/correction of contour defect were selected after preoperative clinical and radiographic (computed tomography scan) evaluation. All the cases were operated by coronal approach to gain the access to the fracture/defect site for reduction/correction of the defect. Advantages and complication are evaluated. Excellent access and anatomical reduction by this approach with least number of complications; if it is performed with healthy knowledge of anatomy of the scalp and temporal region. Certain minimal complications have also been noted using various modifications used in the procedure. Despite of prolonged surgical time for the exposure, it is very advantages in treating upper and middle third facial fractures due to wide access and discreet scar (minimal).

  18. THE EFFECT OF STRAIN RATE ON FRACTURE TOUGHNESS OF HUMAN CORTICAL BONE: A FINITE ELEMENT STUDY

    PubMed Central

    Ural, Ani; Zioupos, Peter; Buchanan, Drew; Vashishth, Deepak

    2011-01-01

    Evaluating the mechanical response of bone under high loading rates is crucial to understanding fractures in traumatic accidents or falls. In the current study, a computational approach based on cohesive finite element modeling was employed to evaluate the effect of strain rate on fracture toughness of human cortical bone. Two-dimensional compact tension specimen models were simulated to evaluate the change in initiation and propagation fracture toughness with increasing strain rate (range: 0.08 to 18 s−1). In addition, the effect of porosity in combination with strain rate was assessed using three-dimensional models of microcomputed tomography-based compact tension specimens. The simulation results showed that bone’s resistance against the propagation of fracture decreased sharply with increase in strain rates up to 1 s−1 and attained an almost constant value for strain rates larger than 1 s−1. On the other hand, initiation fracture toughness exhibited a more gradual decrease throughout the strain rates. There was a significant positive correlation between the experimentally measured number of microcracks and the fracture toughness found in the simulations. Furthermore, the simulation results showed that the amount of porosity did not affect the way initiation fracture toughness decreased with increasing strain rates, whereas it exacerbated the same strain rate effect when propagation fracture toughness was considered. These results suggest that strain rates associated with falls lead to a dramatic reduction in bone’s resistance against crack propagation. The compromised fracture resistance of bone at loads exceeding normal activities indicates a sharp reduction and/or absence of toughening mechanisms in bone during high strain conditions associated with traumatic fracture. PMID:21783112

  19. [Effective analysis of percutaneous reduction and Kirschner pin fixation for the treatment of intraarticular fractures of the calcaneus in children].

    PubMed

    Huang, Zhong-sheng; Zhao, Zhen; Ji, Ying-yao; Li, Ke-lun; Zheng, Ju-han; Ni, Jian-guang; Xu, Can-zhen; Zheng, Li-cheng

    2011-10-01

    To introduce and evaluate the clinical effects of percutaneous reduction and Kirschner pin fixation for the treatment of intraarticular fractures of the calcaneus in children. From March 2001 to February 2009,12 patients with intraarticular calcaneal fractures were treated by percutaneous reduction and Kirschner pin fixation (13 feet). There were 8 males and 4 females,ranging in age from 3 to 14,with an average of 8.7 years. According to Essex-Lopresti classification, among 5 feet were tongue fractures and 8 feet were compressed fractures. According to Sanders classification, 9 feet were type II and 4 feet were type III. The Biihler angle and Gissane angle of the calcaneus were obtained before and after operation. All patients were evaluated according to Maryland Foot Score. All the patients were followed up for 16-71 months (means 35.9 months),and all the incisions were healed without complications and infection. The preoperative X-ray film showed that Böhler angle was (19.7+/-5.3) degrees, Gissane angle was (137.3+/-7.5) degrees. The postoperative X-ray film demonstrated that Böhler angle was (32.6+/-3.7) degrees, Gissane angle was (125.4+/-2.9) degrees. There was a significant difference between preoperative and postoperative (P<0.01). The average Maryland score was 96.3+/-2.4 (range, 92 to 100 points). Percutaneous reduction and Kirschner pin fixation is an effective minimally invasive way to treat intraarticular fractures of the calcaneus in children, it has many advantages such as minimal invasion, reliable fixation and satisfactory effects.

  20. Role of Ankle Arthroscopy in Management of Acute Ankle Fracture.

    PubMed

    Chan, Kwok Bill; Lui, Tun Hing

    2016-11-01

    To report the operative findings of ankle arthroscopy during open reduction and internal fixation of acute ankle fractures. This was a retrospective review of 254 consecutive patients with acute ankle fractures who were treated with open reduction and internal fixation of the fractures, and ankle arthroscopy was performed at the same time. The accuracy of fracture reduction, the presence of syndesmosis disruption and its reduction, and the presence of ligamentous injuries and osteochondral lesions were documented. Second-look ankle arthroscopy was performed during syndesmosis screw removal 6 weeks after the key operation. There were 6 patients with Weber A, 177 patients with Weber B, 51 patients with Weber C, and 20 patients with isolated medial malleolar fractures. Syndesmosis disruption was present in 0% of patients with Weber A fracture, 52% of patients with Weber B fracture, 92% of patients with Weber C fracture, and 20% of the patients with isolated medial malleolar fracture. Three patients with Weber B and one patient with Weber C fracture have occult syndesmosis instability after screw removal. Osteochondral lesion was present in no patient with Weber A fracture, 26% of the Weber B cases, 24% of the Weber C cases, and 20% of isolated medial malleolar fracture cases. The association between the presence of deep deltoid ligament tear and syndesmosis disruption (warranting syndesmosis screw fixation) in Weber B cases was statistically significant but not in Weber C cases. There was no statistically significant association between the presence of posterior malleolar fracture and syndesmosis instability that warrant screw fixation. Ankle arthroscopy is a useful adjuvant tool to understand the severity and complexity of acute ankle fracture. Direct arthroscopic visualization ensures detection and evaluation of intra-articular fractures, syndesmosis disruption, and associated osteochondral lesions and ligamentous injuries. Level IV, case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Computer-assisted virtual preoperative planning in orthopedic surgery for acetabular fractures based on actual computed tomography data.

    PubMed

    Wang, Guang-Ye; Huang, Wen-Jun; Song, Qi; Qin, Yun-Tian; Liang, Jin-Feng

    2016-12-01

    Acetabular fractures have always been very challenging for orthopedic surgeons; therefore, appropriate preoperative evaluation and planning are particularly important. This study aimed to explore the application methods and clinical value of preoperative computer simulation (PCS) in treating pelvic and acetabular fractures. Spiral computed tomography (CT) was performed on 13 patients with pelvic and acetabular fractures, and Digital Imaging and Communications in Medicine (DICOM) data were then input into Mimics software to reconstruct three-dimensional (3D) models of actual pelvic and acetabular fractures for preoperative simulative reduction and fixation, and to simulate each surgical procedure. The times needed for virtual surgical modeling and reduction and fixation were also recorded. The average fracture-modeling time was 45 min (30-70 min), and the average time for bone reduction and fixation was 28 min (16-45 min). Among the surgical approaches planned for these 13 patients, 12 were finally adopted; 12 cases used the simulated surgical fixation, and only 1 case used a partial planned fixation method. PCS can provide accurate surgical plans and data support for actual surgeries.

  2. OC30 - Fracture reduction with nitrous oxide at the children's emergency department shortens the length of stay and reduces the use of full anaesthesia in the operating department.

    PubMed

    Lang, Sigrid; Wentzel, Anna-Pia; Ekstrom, Malin

    2016-05-09

    Theme: Accreditation and quality improvement. Dislocated fractures are common in the children's emergency department (ER). All forms of fracture reduction are very painful requiring nitrous oxide. The purpose is to shorten the length of stay in the hospital as well as sustain a high quality of care. All nurses received theoretical and practical training in the use of nitrous oxide. Evaluations with the families were made by telephone. A total of 40 enclosed fracture reductions were made at the ER, leading to a reduction of 33 patients in the operating department and the length of stay was shortened - this compared to the same time in 2014. No adverse event was reported and no patient felt any increase in pain during the treatment. All patients would repeat the procedure if necessary. The treatment has reduced the length of stay in the hospital without affecting the other patients in the ER or the quality of care.

  3. Semi-closed reduction of tripod fractures of zygoma under intraoperative assessment using ultrasonography.

    PubMed

    Soejima, Kazutaka; Sakurai, Hiroyuki; Nozaki, Motohiro; Kitazawa, Yoshihiko; Takeuchi, Masaki; Yamaki, Takashi; Kono, Taro

    2009-04-01

    We conducted semi-closed reduction of isolated tripod fractures of the zygoma through only a brow incision under intraoperative assessment with ultrasonography. Twenty-three patients with unilateral, non-comminuted tripod fractures of zygoma were selected for application of this method at Tokyo Women's Medical University and Tokyo Metropolitan Hiroo General Hospital between April 2002 and April 2006. Patients with orbital floor blowout fractures were excluded. A skin incision was made only at the lateral brow region and the reduction was performed by inserting an elevator beneath the zygomatic arch. The bone alignment was intraoperatively assessed by ultrasonography. When the reduction was accurate, the frontozygomatic suture was immobilised with a mini-plate under direct visualisation and transmaler Kirshner wire fixation was performed. The accuracy of the reduction and postoperative movement were evaluated by computed tomography (CT) scans taken at 1 and 6 months. In five cases, the DICOM (Digital Imaging and Communication in Medicine) data from the CT were analysed with 3D imaging software (V-works, CyberMed Co., Korea). In all cases, accurate reduction was obtained. The analysis of the 3D imaging data revealed that postoperative movement of bone fragment was minimal. When the accurate reduction was obtained under intraoperative assessment, the semi-closed reduction and one-plate fixation with transmaler Kirshner wire is enough to treat the simple tripod fractures of zygoma. This method is minimally invasive and takes less operative time.

  4. Effects of the Ratio between Pigment and Bleaching Gel on the Fracture Resistance and Dentin Microhardness of endodontically treated Teeth.

    PubMed

    Galloza, Marina Og; Jordão-Basso, Keren Cf; Bandeca, Matheus C; Costa, Samuel O; Borges, Alvaro H; Tonetto, Mateus R; Tirintan, Fabio C; Keine, Kátia C; Kuga, Milton C

    2017-11-01

    The aim of this study was to evaluate the effects of bleaching gel using 35% hydrogen peroxide (HP), associated with red carmine pigment (RC), in the 3:1 or 1:1 ratio, on fracture resistance and dentin microhardness of endodontically treated teeth. A total of 40 lower incisors were endodontically treated and divided into four groups (n = 10), according to the bleaching protocol: G1 (HP3), 35% HP + RC (3:1); G2 (HP1), 35% HP + RC (1:1); G3 (positive), 38% HP; and G4 (negative), unbleached. Four dental bleaching sessions were performed. The dental crowns were restored after the last session and submitted to the fracture resistance test. Totally, 60 specimens from the endodontically treated lower incisor crowns were prepared to evaluate the effects on dentin microhardness. The analysis was measured (in Knoop) prior to and after the last dental bleaching session using similar bleaching protocols. G2 presented the lowest fracture resistance (p < 0.05). The other groups were similar to each other (p > 0.05). No difference was observed in the reduction of dentin microhardness among the groups (p > 0.05). A 1:1 ratio (bleaching gel:pigment) caused a significant fracture resistance reduction in relation to the other protocols. No effect on the dentin microhardness reduction was observed. The pigment addition to the bleaching agent accelerates the bleaching chemical reaction. However, no studies have evaluated the ideal proportion to optimize tooth bleaching.

  5. [Application of three-dimensional printing personalized acetabular wing-plate in treatment of complex acetabular fractures via lateral-rectus approach].

    PubMed

    Mai, J G; Gu, C; Lin, X Z; Li, T; Huang, W Q; Wang, H; Tan, X Y; Lin, H; Wang, Y M; Yang, Y Q; Jin, D D; Fan, S C

    2017-03-01

    Objective: To investigate reduction and fixation of complex acetabular fractures using three-dimensional (3D) printing technique and personalized acetabular wing-plate via lateral-rectus approach. Methods: From March to July 2016, 8 patients with complex acetabular fractures were surgically managed through 3D printing personalized acetabular wing-plate via lateral-rectus approach at Department of Orthopedics, the Third Affiliated Hospital of Southern Medical University. There were 4 male patients and 4 female patients, with an average age of 57 years (ranging from 31 to 76 years). According to Letournel-Judet classification, there were 2 anterior+ posterior hemitransverse fractures and 6 both-column fractures, without posterior wall fracture or contralateral pelvic fracture. The CT data files of acetabular fracture were imported into the computer and 3D printing technique was used to print the fractures models after reduction by digital orthopedic technique. The acetabular wing-plate was designed and printed with titanium. All fractures were treated via the lateral-rectus approach in a horizontal position after general anesthesia. The anterior column and the quadrilateral surface fractures were fixed by 3D printing personalized acetabular wing-plate, and the posterior column fractures were reduction and fixed by antegrade lag screws under direct vision. Results: All the 8 cases underwent the operation successfully. Postoperative X-ray and CT examination showed excellent or good reduction of anterior and posterior column, without any operation complications. Only 1 case with 75 years old was found screw loosening in the pubic bone with osteoporosis after 1 month's follow-up, who didn't accept any treatment because the patient didn't feel discomfort. According to the Matta radiological evaluation, the reduction of the acetabular fracture was rated as excellent in 3 cases, good in 4 cases and fair in 1 case. All patients were followed up for 3 to 6 months and all patients had achieved bone union. According to the modified Merle D'Aubigné and Postel scoring system, 5 cases were excellent, 2 cases were good, 1 case was fair. Conclusions: Surgical management of complex acetabular fracture via lateral-rectus approach combine with 3D printing personalized acetabular wing-plate can effectively improve reduction quality and fixation effect. It will be truly accurate, personalized and minimally invasive.

  6. Isolated displaced non-union of a triquetral body fracture: a case report

    PubMed Central

    2012-01-01

    Introduction Fractures of the body of the triquetral bone are the second most common carpal fractures, and these fractures can be missed on plain X-ray. Although non-union of triquetral body fractures is very rare, such cases are associated with considerable morbidity and reduction in functional activity. Case presentation We report the case of a 29-year-old Caucasian British man who sustained an isolated displaced triquetral body fracture that resulted in non-union, who was treated surgically. We describe an original operative management for this debilitating injury. An open reduction and internal fixation using double headed compression screws was performed, without bone grafting, and with early immobilization of the wrist. Conclusions We propose this novel approach and advocate early clinical suspicion of triquetral body fractures in patients with a history of fall on an outstretched hand and ulnar sided wrist pain. We recommend evaluation using computed tomography or magnetic resonance imaging scanning. PMID:22325450

  7. Rib fractures in trauma patients: does operative fixation improve outcome?

    PubMed

    Majak, Peter; Næss, Pål A

    2016-12-01

    Renewed interest in surgical fixation of rib fractures has emerged. However, conservative treatment is still preferred at most surgical departments. We wanted to evaluate whether operative treatment of rib fractures may benefit severely injured patients. Several studies report a reduction in mechanical ventilation time, ICU length of stay (LOS), hospital LOS, pneumonia, need for tracheostomy, pain and costs in operatively treated patients with multiple rib fractures compared with patients treated nonoperatively. Although patient selection and timing of the operation seem crucial for successful outcome, no consensus exists. Mortality reduction has only been shown in a few studies. Most studies are retrospective cohort and case-control studies. Only four randomized control trials exist. Conservative treatment, consisting of respiratory assistance and pain control, is still the treatment of choice in the vast majority of patients with multiple rib fractures. In selected patients, operative fixation of fractured ribs within 72 h postinjury may lead to better outcome. More randomized control trials are needed to further determine who benefits from surgical fixation of rib fractures.

  8. Internal Fixation of Complicated Acetabular Fractures Directed by Preoperative Surgery with 3D Printing Models.

    PubMed

    Liu, Zhao-Jie; Jia, Jian; Zhang, Yin-Guang; Tian, Wei; Jin, Xin; Hu, Yong-Cheng

    2017-05-01

    The purpose of this article is to evaluate the efficacy and feasibility of preoperative surgery with 3D printing-assisted internal fixation of complicated acetabular fractures. A retrospective case review was performed for the above surgical procedure. A 23-year-old man was confirmed by radiological examination to have fractures of multiple ribs, with hemopneumothorax and communicated fractures of the left acetabulum. According to the Letounel and Judet classification, T-shaped fracture involving posterior wall was diagnosed. A 3D printing pelvic model was established using CT digital imaging and communications in medicine (DICOM) data preoperatively, with which surgical procedures were simulated in preoperative surgery to confirm the sequence of the reduction and fixation as well as the position and length of the implants. Open reduction with internal fixation (ORIF) of the acetabular fracture using modified ilioinguinal and Kocher-Langenbeck approaches was performed 25 days after injury. Plates that had been pre-bent in the preoperative surgery were positioned and screws were tightened in the directions determined in the preoperative planning following satisfactory reduction. The duration of the operation was 170 min and blood loss was 900 mL. Postoperative X-rays showed that anatomical reduction of the acetabulum was achieved and the hip joint was congruous. The position and length of the implants were not different when compared with those in preoperative surgery on 3D printing models. We believe that preoperative surgery using 3D printing models is beneficial for confirming the reduction and fixation sequence, determining the reduction quality, shortening the operative time, minimizing preoperative difficulties, and predicting the prognosis for complicated fractures of acetabulam. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  9. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    PubMed

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p < 0.05): open fracture (OR 3.78; 95% CI 2.71-5.27), compartment syndrome (OR 3.53; 95% CI 2.13-5.86), operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  10. Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.

    PubMed

    Yi, Chengla; Burns, Sean; Hak, David J

    2014-01-01

    The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and are gaining popularity in the management of pelvic and acetabular fractures. These techniques require knowledge and interpretation of various fluoroscopic images to ensure appropriate and safe screw placement. Given the anatomic complexity of the intrapelvic structures and the 2-dimensional nature of standard fluoroscopy, multiple images oriented in different planes are needed to assess the accuracy of guide wire and screw placement. This article reviews the fluoroscopic imaging of common screw orientations during pelvic and acetabular surgery.

  11. Percutaneous Dorsal Instrumentation of Vertebral Burst Fractures: Value of Additional Percutaneous Intravertebral Reposition—Cadaver Study

    PubMed Central

    Krüger, Antonio; Schmuck, Maya; Noriega, David C.; Ruchholtz, Steffen; Baroud, Gamal; Oberkircher, Ludwig

    2015-01-01

    Purpose. The treatment of vertebral burst fractures is still controversial. The aim of the study is to evaluate the purpose of additional percutaneous intravertebral reduction when combined with dorsal instrumentation. Methods. In this biomechanical cadaver study twenty-eight spine segments (T11-L3) were used (male donors, mean age 64.9 ± 6.5 years). Burst fractures of L1 were generated using a standardised protocol. After fracture all spines were allocated to four similar groups and randomised according to surgical techniques (posterior instrumentation; posterior instrumentation + intravertebral reduction device + cement augmentation; posterior instrumentation + intravertebral reduction device without cement; and intravertebral reduction device + cement augmentation). After treatment, 100000 cycles (100–600 N, 3 Hz) were applied using a servohydraulic loading frame. Results. Overall anatomical restoration was better in all groups where the intravertebral reduction device was used (p < 0.05). In particular, it was possible to restore central endplates (p > 0.05). All techniques decreased narrowing of the spinal canal. After loading, clearance could be maintained in all groups fitted with the intravertebral reduction device. Narrowing increased in the group treated with dorsal instrumentation. Conclusions. For height and anatomical restoration, the combination of an intravertebral reduction device with dorsal instrumentation showed significantly better results than sole dorsal instrumentation. PMID:26137481

  12. Closed Versus Open Supracondylar Fractures of the Humerus in Children: A Comparison of Clinical and Radiographic Presentation and Results.

    PubMed

    Lewine, Eliza; Kim, Jaehon M; Miller, Patricia E; Waters, Peter M; Mahan, Susan T; Snyder, Brian; Hedequist, Daniel; Bae, Donald S

    2018-02-01

    The purpose of this investigation was to compare the presentation and postoperative results of children treated for open and closed, completely displaced type III supracondylar humerus fractures (SCFs). Thirty patients with open and 66 patients with closed, completely displaced type III SCFs were evaluated. Open fractures underwent irrigation and debridement, and all patients were treated by open or closed reduction and pin fixation. Medical records were reviewed to obtain demographic information as well as preoperative and postoperative clinical data regarding mechanism of injury, neurovascular status, associated injuries, postoperative range of motion, infections, and pain. Radiographs were evaluated to quantify displacement, Baumann's angle, humeral capitellar angle, position of the anterior humeral line, and adequacy of reduction. Outcomes were assessed using Flynn criteria. Mean clinical follow-up for the open and closed fracture groups was 8.9 and 5.7 months, respectively. Both groups were similar with respect to age, sex distribution, weight and body mass index, laterality of involvement, and mechanism of injury. At presentation, 35% of closed SCFs and 23% of open SCFs presented with abnormal neurovascular status. There was a higher prevalence of diminished/absent pulses or distal limb ischemia in patients with open injuries (27%) compared with closed fractures (18%). Conversely, severely displaced closed fractures were more commonly associated with nerve injury/palsy at presentation (35%) than those with open fractures (23%). Spontaneous nerve recovery was seen in 87% within 3 to 6 months. Postoperative loss of reduction and malunion were more common in the closed fracture group. However, 84% of patients achieved good-to-excellent results by Flynn criteria, with no appreciable difference based upon open versus closed fractures. With timely wound and fracture treatment, the clinical and radiographic results of children treated for open SCFs is similar to those with closed type III injuries, with little increased risk for infection, malunion, or neurovascular compromise. Level III.

  13. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    PubMed

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  14. Mixing implants of differing metallic composition in the treatment of upper-extremity fractures.

    PubMed

    Acevedo, Daniel; Loy, Bo Nasmyth; Loy, Bo Nasymuth; Lee, Brian; Omid, Reza; Itamura, John

    2013-09-01

    Mixing implants with differing metallic compositions has been avoided for fear of galvanic corrosion and subsequent failure of the implants and of bone healing. The purpose of this study was to evaluate upper-extremity fractures treated with open reduction and internal fixation with metallic implants that differed in metallic composition placed on the same bone. The authors studied the effects of using both stainless steel and titanium implants on fracture healing, implant failure, and other complications associated with this method of fixation. Their hypothesis was that combining these metals on the same bone would not cause clinically significant nonunions or undo clinical effects from galvanic corrosion. A retrospective review was performed of 17 patients with upper-extremity fractures fixed with metal implants of differing metallic compositions. The primary endpoint was fracture union. Eight clavicles, 2 proximal humeri, 3 distal humeri, 3 olecranons, and 1 glenoid fracture with an average follow-up 10 months were reviewed. All fractures healed. One patient experienced screw backout, which did not affect healing. This study implies that mixing implants with differing metallic compositions on the same bone for the treatment of fractures does not adversely affect bone healing. No evidence existed of corrosion or an increase in complications with this method of treatment. Contrary to prior belief, small modular hand stainless steel plates can be used to assist in reduction of smaller fracture fragments in combination with anatomic titanium plates to obtain anatomic reduction of the fracture without adversely affecting healing. Copyright 2013, SLACK Incorporated.

  15. Evaluation of Shear Strength of RC Beams with Multiple Interfaces Formed before Initial Setting Using 3D Printing Technology

    PubMed Central

    Kim, Kyeongjin; Park, Sangmin; Jeong, Yoseok; Lee, Jaeha

    2017-01-01

    With the recent development of 3D printing technology, concrete materials are sometimes used in 3D printing. Concrete structures based on 3D printing have been characterized to have the form of multiple layer build-up. Unlike general concrete structures, therefore, the 3D-printed concrete can be regarded as an orthotropic material. The material property of the 3D-printed concrete’s interface between layers is expected to be far different from that of general concrete bodies since there are no aggregate interlocks and weak chemical bonding. Such a difference finally affects the structural performance of concrete structures even though the interfaces are formed before initial setting of the concrete. The current study mainly reviewed the changes in fracture energy (toughness) with respect to various environmental conditions of such interface. Changes in fracture energies of interfaces between concrete layers were measured using low-speed Crack Mouth Opening Displacement (CMOD) closed loop concrete fracture test. The experimental results indicated reduction in fracture energy as well as tensile strengths. To improve the tensile strength of interfaces, the use of bridging materials is suggested. Since it was assumed that reduction in fracture energy could be a cause of shear strength, to evaluate the reduced structural performance of concrete structure constructed with multiple interfaces by 3D printing technology, the shear strength of RC beam by 3D printing technology was predicted and compared with that of plain RC beam. Based on the fracture energy measured in this study, Modified Compression Field Theory (MCFT) theory-applied Vector 2 program was employed to predict the degree of reduction in shear strength without considering stirrups. Reduction factors were presented based on the obtained results to predict the reduction in shear strength due to interfaces before initial setting of the concrete.

  16. Treatment of mandibular symphyseal fracture combined with dislocated intracapsular condylar fractures.

    PubMed

    Xu, Xiaofeng; Shi, Jun; Xu, Bing; Dai, Jiewen; Zhang, Shilei

    2015-03-01

    To evaluate the treatment methods of mandibular symphyseal fracture combined with dislocated intracapsular condylar fractures (MSF&DICF) and to compare the effect of different treatment methods of condylar fractures. Twenty-eight patients with MSF&DICF were included in this study. Twenty-two sites were treated by open reduction, and all the medial condylar fragments were fixed with titanium screws; whereas the other 22 sites underwent close treatment. The surgical effect between these 2 groups was compared based on clinical examination and radiographic examination results. Seventeen of 22 condyle fractures were repositioned in the surgery group, whereas 4 of 22 condyle fractures were repositioned in the close treatment group. Statistical difference was observed between these 2 groups (P < 0.01). Functional outcomes of the patients treated in the surgical treatment group also were better than those in the close treatment group. The dislocated intracapsular condyle fractures should be treated by surgical reduction with the maintenance of the attachment of lateral pterygoid muscle, which is beneficial to repositioning the dislocated condyle to its original physiological position, to closure of the mandibular lingual gap, to restore the mandibular width.

  17. Impact of Open Reduction on Surgical Strategies for Missed Monteggia Fracture in Children.

    PubMed

    Park, Hoon; Park, Kwang Won; Park, Kun Bo; Kim, Hyun Woo; Eom, Nam Kyu; Lee, Dong Hoon

    2017-07-01

    The aims of this study were to review our cases of missed Monteggia fracture treated by open reduction of the radial head with or without ulnar osteotomy and to investigate the indications for open reduction alone in surgical treatment of missed Monteggia fracture. We retrospectively reviewed 22 patients who presented with missed Monteggia fracture. The patients' mean age at the time of surgery was 7.6 years. The mean interval from injury to surgery was 16.1 months. The surgical procedure consisted of open reduction of the radiocapitellar joint followed by ulnar osteotomy without reconstruction of the annular ligament. The mean period of follow-up was 3.8 years. Radiographic assessment was performed for the maximum ulnar bow (MUB) and the location of the MUB. Clinical results were evaluated with the Mayo Elbow Performance Index and Kim's scores. Five patients underwent open reduction alone, and 17 patients underwent open reduction and ulnar osteotomy. When the MUB was less than 4 mm and the location of the MUB was in the distal 40% of the ulna, we could achieve reduction of the radial head without ulnar osteotomy. The radial head was maintained in a completely reduced position in 21 patients and was dislocated in one patient at final follow-up. Open reduction alone can be an attractive surgical option in select patients with missed Monteggia fracture with minimal bowing of the distal ulna. However, ulnar osteotomy should be considered in patients with a definite ulnar deformity. © Copyright: Yonsei University College of Medicine 2017

  18. Angular stable plates in proximal meta-epiphyseal tibial fractures: study of joint restoration and clinical and functional evaluation.

    PubMed

    Giannotti, S; Giovannelli, D; Dell'Osso, G; Bottai, V; Bugelli, G; Celli, F; Citarelli, C; Guido, G

    2016-04-01

    The tibial plateau fractures involve one of the main weight bearing joints of the human body. The goals of surgical treatment are anatomical reduction, articular surface reconstruction and high primary stability. The aim of this study was to evaluate the clinical and functional outcomes after internal plate fixation of this kind of fractures. From January 2009 to December 2012, we treated 75 cases of tibial plateau fracture with angular stable plates. We used Rasmussen Score and the Knee Society Score for the clinical and functional evaluation. Twenty-five cases that underwent hardware removal had arthroscopic and CT evaluation of the joint. No complications occurred. The clinical and functional evaluation, performed by the KSS and Rasmussen Score, highlighted the high percentage of good-to-excellent results (over 90 %). In every case, the range of motion was good with flexion >90°. Arthroscopy showed the presence of chondral damage in 100 % of patients. In all the cases, we found that X-ray images seem better than the CT images. Angular stable plates allow to obtain a good primary stability, permitting an early joint recovery with an excellent range of motion. Avoiding to perform a knee arthrotomy at the time of fracture reduction could prove to be an advantage in terms of functional recovery. The meniscus on the injured bone should be preserved in order to maintain good function of the joint. X-ray images remain the gold standard in checking the progression of post-traumatic osteoarthritis.

  19. Transoral open reduction and fixation of mandibular condylar base and neck fractures in children and young teenagers--a beneficial treatment option?

    PubMed

    Schiel, Sebastian; Mayer, Peter; Probst, Florian; Otto, Sven; Cornelius, Carl-Peter

    2013-07-01

    To evaluate the possible benefits of open surgery, endoscopically assisted reduction and fixation using a transoral route was used in a selected series of pediatric patients with displaced condylar base and neck fractures. A cohort of 6 patients (1 male and 5 female; age range, 7 to 15 yr; mean, 13.4 yr) with displaced condylar base and neck fractures (n = 9) were included. Inclusion criteria were age younger than 16 years, fracture of the condylar base or neck, and displacement of the fracture by at least 45°. Fractures were classified using conventional radiography, cone-beam computed tomography, or computed tomography. Patients underwent transoral endoscopically assisted open reduction and fixation using miniplate osteosynthesis. Postoperatively, patients were followed clinically and radiographically for 18 months. Complete follow-up varied from 18 to 35 months (median, 24.5 months). All patients showed normal occlusion and pain-free unrestricted function of the temporomandibular joint at 3, 6, 12, and 18 months postoperatively. There were no signs of incomplete remodeling or deformation of the condyles. Transoral endoscopically assisted surgical treatment of severely displaced condylar base and neck fractures in children and young teenagers offers a reliable solution to preclude the sequelae of closed treatment, such as altered morphology and functional disturbances, eliminates visible scars, and lowers the risk of facial nerve damage compared with open reduction using an extraoral approach. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  20. Oral-motor and electromyographic characterization of patients submitted to open a nd closed reductions of mandibular condyle fracture.

    PubMed

    Silva, Amanda Pagliotto da; Sassi, Fernanda Chiarion; Andrade, Claudia Regina Furquim de

    To characterize the oral-motor system of adults with mandibular condyle facture comparing the performance of individuals submitted to open reduction with internal fixation (ORIF) and closed reduction with mandibulomaxillary fixation (CRMMF). Study participants were 26 adults divided into three groups: G1 - eight individuals submitted to ORIF for correction of condyle fracture; G2 - nine individuals submitted to CRMMF for correction of condyle fracture; CG - nine healthy volunteers with no alterations of the orofacial myofunctional system. All participants underwent the same clinical protocol: assessment of the orofacial myofunctional system; evaluation of the mandibular range of motion; and surface electromyography (sEMG) of the masticatory muscles. Results indicated that patients with condyle fractures from both groups presented significant differences compared with those from the control group in terms of mobility of the oral-motor organs, mastication, and deglutition. Regarding the measures obtained for mandibular movements, participants with facial fractures from both groups showed significant differences compared with those from the control group, indicating greater restrictions in mandibular motion. As for the analysis of sEMG results, G1 patients presented more symmetrical masseter activation during the task of maximal voluntary teeth clenching. Patients with mandibular condyle fractures present significant deficits in posture, mobility, and function of the oral-motor system. The type of medical treatment does not influence the results of muscle function during the first six months after fracture reduction. Individuals submitted to ORIF of the condyle fracture present more symmetrical activation of the masseter muscle.

  1. Effects of exercise on fracture reduction in older adults: a systematic review and meta-analysis.

    PubMed

    Kemmler, W; Häberle, L; von Stengel, S

    2013-07-01

    In this meta-analysis, we evaluated the effect of exercise on fracture reduction in the elderly. Our results determined a significantly positive effect on overall fractures, whereas the possibility of a publication bias indicates the need for well-designed (multi-center) trials that generate enough power to focus on osteoporotic fractures. The preventive effect of exercise on fracture incidence has not been clearly determined yet. Thus, the purpose of this study is to evaluate the effectiveness of exercise in preventing overall and vertebral fractures in older adults by meta-analyses technique. This study followed the PRISMA recommendations for systematic reviews and meta-analyses. A systematic review of English articles between 1980 and March 2012 was performed. Terms used were: "exercise", "fractures", "bone", "falls", "osteoporosis", "BMD", "BMC", "bone turnover", while the search was limited to "clinical trial" and "humans". Controlled exercise trials that reported fracture number as endpoint or observation in subjects 45 years and older were included. Ten controlled exercise trials that reported overall fractures and three exercise trials that reported vertebral fractures met our inclusion criteria. Overall fracture number in the exercise group was 36 (n = 754) compared with 73 fractures in the CG (n = 670) (relative risk [RR] = 0.49; 95 % confidence interval [CI], 0.31-0.76). No significant heterogeneity of trial results (p = 0.28; I (2) = 17) was determined; however, there was some evidence to suggest a publication bias. The overall RR for vertebral fracture number (0.56; 95 % CI, 0.30-1.04) (EG: 19 fractures/103 subjects vs. CG: 31 fractures/102 subjects) was borderline non-significant while the heterogeneity of trial results also cannot be ruled out. Although there is evidence that exercise reduces overall and, to a lesser degree, vertebral fractures in the elderly, the possibility of publication bias weakens our result and demonstrates the imperative for large exercise studies with dedicated exercise protocols that focus on fractures as a primary endpoint.

  2. Modified preauricular approach and rigid internal fixation for intracapsular condyle fracture of the mandible.

    PubMed

    He, Dongmei; Yang, Chi; Chen, Minjie; Bin, Jiang; Zhang, Xiaohu; Qiu, Yating

    2010-07-01

    This article reports a modified preauricular approach for intracapsular condyle fracture (ICF) of the mandible and evaluates the stability of various internal fixation methods in the temporomandibular joint (TMJ) division of the Shanghai Ninth People's Hospital. One hundred fifty-one patients with 208 ICFs diagnosed by panoramic radiograph and computed tomographic (CT) scan received open treatment in the TMJ division from 1999 to 2008. Their charts were reviewed. Classification of the fracture was based on coronal CT scan. Forty-three patients also underwent magnetic resonance imaging before the operation to check displacement of the disc. A modified preauricular approach was used for all patients. Various internal fixation methods from wire, to screw, to plate were evaluated for stability. There were 110 ICFs of type A fracture, 60 of type B fracture, 9 of type C fracture, 25 of type M fracture, and 4 fractures without displacement. A modified preauricular approach was used for open treatment, which can better expose and protect the TMJ and superficial temporal vessels. Wire and plate is the commonly used stable fixation method for type A, B, and M fractures, which accounted for 56.7% (101/178). Small fracture fragments were removed with disc repositioning for all type C fractures (n = 9) and some type B (n = 9) and M fractures (n = 5). Three type M fracture and 3 nondisplaced ICFs were treated closed. Eighty-nine patients with 115 ICFs had postoperative CT scan, which showed anatomic and nearly anatomic fracture reduction rates of 95.6%. Thirty-five patients with 44 ICFs had long-term follow-ups from 3 months to 5 years. Among them, 63.2% (n = 12/19) pediatric ICFs had continuous condyle growth after open reduction and rigid fixation; 92% adults had ICFs that healed well (n = 23/25). Postoperative complications were facial nerve injury (n = 3), TMJ clicking (n = 1), and condyle resorption that required plate removal (n = 4). A modified preauricular approach provides better exposure and protection of the TMJ and superficial temporal vessels. Wire and plate provides stable fixation for type A and some type B and M fractures. Open reduction and rigid fixation produce good results for adult patients. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. LORENZ: a system for planning long-bone fracture reduction

    NASA Astrophysics Data System (ADS)

    Birkfellner, Wolfgang; Burgstaller, Wolfgang; Wirth, Joachim; Baumann, Bernard; Jacob, Augustinus L.; Bieri, Kurt; Traud, Stefan; Strub, Michael; Regazzoni, Pietro; Messmer, Peter

    2003-05-01

    Long bone fractures belong to the most common injuries encountered in clinical routine trauma surgery. Preoperative assessment and decision making is usually based on standard 2D radiographs of the injured limb. Taking into account that a 3D - imaging modality such as computed tomography (CT) is not used for diagnosis in clinical routine, we have designed LORENZ, a fracture reduction planning tool based on such standard radiographs. Taking into account the considerable success of so-called image free navigation systems for total knee replacement in orthopaedic surgery, we assume that a similar tool for long bone fracture reposition should have considerable impact on computer-aided trauma surgery in a standard clinical routine setup. The case for long bone fracture reduction is, however, somewhat more complicated since not only scale independent angles indicating biomechanical measures such as varus and valgus are involved. Reduction path planning requires that the individual anatomy and the classification of the fracture is taken into account. In this paper, we present the basic ideas of this planning tool, it's current state, and the methodology chosen. LORENZ takes one or more conventional radiographs of the broken limb as input data. In addition, one or more x-rays of the opposite healthy bone are taken and mirrored if necessary. A most adequate CT model is being selected from a database; currently, this is achieved by using a scale space approach on the digitized x-ray images and comparing standard perspective renderings to these x-rays. After finding a CT-volume with a similar bone, a triangulated surface model is generated, and the surgeon can break the bone and arrange the fragments in 3D according to the x-ray images of the broken bone. Common osteosynthesis plates and implants can be loaded from CAD-datasets and are visualized as well. In addition, LORENZ renders virtual x-ray views of the fracture reduction process. The hybrid surface/voxel rendering engine of LORENZ also features full collision detection of fragments and implants by using the RAPID collision detection library. The reduction path is saved, and a TCP/IP interface to a robot for executing the reduction was added. LORENZ is platform independent and was programmed using Qt, AVW and OpenGL. We present a prototype for computer-aided fracture reduction planning based on standard radiographs. First test on clinical CT-Xray image pairs showed good performance; a current effort focuses on improving the speed of model retrieval by using orthonormal image moment decomposition, and on clinical evaluation for both training and surgical planning purposes. Furthermore, user-interface aspects are currently under evaluation and will be discussed.

  4. Mandibular fractures in children: analysis of 61 cases and review of the literature.

    PubMed

    Glazer, Michael; Joshua, Ben Zion; Woldenberg, Yitzhak; Bodner, Lipa

    2011-01-01

    The purpose was to evaluate the incidence, etiology, site and patterns, management and treatment methods, and outcome of pediatric patients with mandibular fractures. Pediatric patients (1.5-16 years old) with mandibular fractures, treated at the Soroka University Medical Center were included in the study. Age, gender, etiology, site and type of fracture, associated injuries, mode of treatment, outcome, complications, and follow up were evaluated. The cases were divided into 3 age groups: Group A: 1.5-5 years, Group B: 6-11 years, and Group C: 12-16 years. Sixty one patients were included in the study. The male to female ratio was 2:1. Motor vehicle accident was the most common cause. Associated trauma was more common in young children. The condyle was involved in 54% of the fractures. Closed reduction and intermaxillary fixation was the most common treatment used. Complications were rare. Management of mandibular fracture in the pediatric age group is a challenge. The anatomical complexity of the developing mandible and teeth strongly suggest the use of surgical techniques that are different from those routinely used in adults. The conservative approach is recommended. Whenever possible closed reduction should be the treatment of choice. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. Use of point-of-care ultrasound in long bone fractures: a systematic review and meta-analysis.

    PubMed

    Chartier, Lucas B; Bosco, Laura; Lapointe-Shaw, Lauren; Chenkin, Jordan

    2017-03-01

    Long bone fractures (LBFs) are among the most frequent traumatic injuries seen in emergency departments. Reduction and immobilization is the most common form of treatment for displaced fractures. Point-of-care ultrasound (PoCUS) is a promising technique for diagnosing LBFs and assessing the success of reduction attempts. This article offers a comprehensive review of the use of PoCUS for the diagnosis and reduction of LBFs. Data source MEDLINE and EMBASE databases were searched through July 19, 2015. Study selection We included prospective studies that assessed test characteristics of PoCUS in 1) the diagnosis or 2) the reduction of LBFs. The methodological quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data extraction Thirty studies met inclusion criteria (n=3,506; overall fracture rate 48.0%). Test characteristics of PoCUS for the diagnosis of LBFs were as follows: sensitivity 64.7%-100%, specificity 79.2%-100%, positive likelihood ratio (LR) 3.11-infinity, and negative LR zero-0.45. Sensitivity and specificity for the adequate reduction of LBFs with PoCUS were 94%-100% and 56%-100%, respectively. PoCUS diagnosis of pediatric forearm fractures in 10 studies showed a pooled sensitivity of 93.1% (95% confidence interval [CI], 87.2%-96.4%) and specificity of 92.9% (95% CI, 86.6%-96.4%), and PoCUS diagnosis of adult ankle fractures in four studies showed a pooled sensitivity of 89.5% (95% CI, 77.0%-95.6%) and specificity of 94.2% (95% CI, 86.1%-97.7%). PoCUS demonstrates good diagnostic accuracy in all LBFs studied, especially in pooled results of diagnosis of pediatric forearm and adult ankle fractures. PoCUS is an appropriate adjunct to plain radiographs for LBFs.

  6. Fracture of mandibular condyle—to open or not to open: an attempt to settle the controversy.

    PubMed

    Rastogi, Sanjay; Sharma, Siddharth; Kumar, Sanjeev; Reddy, Mahendra P; Niranjanaprasad Indra, B

    2015-06-01

    To compare the outcome of the open method versus the closed method of treatment for mandibular condylar fracture. Fifty patients with fractures of the mandibular condylar processes were evaluated. All fractures were displaced, with a degree of deviation between the condylar fragment and the ascending ramus of 10 to 45 degrees (mediolaterally). The patients were randomly divided into two groups, with group 1 receiving open reduction internal fixation and group 2 receiving closed reduction. The follow-up was done over the period of 6 months. Statistically significant improvement was seen in group 1 compared with group 2 in terms of anatomic reduction of the condyle, shortening of the ascending ramus, occlusal status, and deviation on mouth opening. A statistically significant difference was seen in the patients treated with the open method, with improved temporomandibular joint functions and fewer short- and long-term complications compared with those treated with the closed method. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Transoral Open Reduction for Subcondylar Fractures of the Mandible Using an Angulated Screwdriver System.

    PubMed

    Nam, Seung Min; Kim, Yong Bae; Cha, Han Gyu; Wee, Syeo Young; Choi, Chang Yong

    2015-09-01

    The management of subcondylar mandibular fractures has been a matter of controversy. Although closed reduction is the most useful method, it can be difficult to achieve anatomical reduction with this technique compared with open reduction and internal fixation (ORIF). Most surgeons prefer to treat subcondylar fractures by extraoral approaches rather than intraoral approaches because extraoral approaches provide good visualization of the operative field. The retromandibular, submandibular, and perilobular approaches are commonly performed in the treatment of displaced condylar or subcondylar fractures and that the functional results of these treatments are good. However, extraoral approaches have a high rate of surgical complications such as salivary fistula formation, visible scarring, and facial nerve injury, compared with intraoral approaches. Therefore, this clinical study evaluated the clinical results of ORIF for mandibular subcondylar fractures through a transoral approach using an angulated screwdriver system without endoscopic assistance. A study was conducted between March 2011 and October 2012. Eleven patients with subcondylar fractures of the mandible were treated through a transoral approach using an angulated screwdriver. There were 10 male patients and 1 female patient aged 21 to 72 years (mean, 38 years). Nine patients had a symphyseal or parasymphyseal fracture, and 2 patients had isolated subcondylar fractures of the mandible. Eleven patients with subcondylar fractures of the mandible were treated with a transoral approach using an angulated screwdriver. The subcondylar fracture was on the left side in 6 patients and on the right in 5. All patients achieved satisfactory ranges of temporomandibular joint movement with an interincisal distance of more than 40 mm without deviation and stable individual centric occlusion. The maximum operation duration was 165 minutes, and the average duration of ORIF was 97 minutes. The association between the operation duration and the number of operations was statistically significant. Our clinical study shows that subcondylar fractures of the mandible can be treated using an angulated screwdriver system through a transoral approach and that this technique provides reliable, satisfactory, and safe clinical outcomes.

  8. Comparative evaluation of rotary ProTaper, Profile, and conventional stepback technique on reduction in Enterococcus faecalis colony-forming units and vertical root fracture resistance of root canals.

    PubMed

    Singla, Mamta; Aggarwal, Vivek; Logani, Ajay; Shah, Naseem

    2010-03-01

    The purpose of this in vitro study was to evaluate the effect of various root canal instrumentation techniques with different instrument tapers on cleaning efficacy and resultant vertical root fracture (VRF) strength of the roots. Fifty human mandibular first premolar roots were enlarged to ISO size 20, inoculated with Enterococcus faecalis [ATCC2912] for 72 hours and divided into 5 groups: group I: prepared with .02 taper hand instruments ISO size 40; group II: Profile .04 taper size 40; group III: Profile .06 taper size 40; group IV: ProTaper size F4; and group V (control group) further divided into: Va: with bacterial inoculation and no mechanical instrumentation; and Group Vb: neither bacterial inoculation nor mechanical instrumentation. Cleaning efficacy was evaluated in terms of reduction of colony forming units (CFUs). The VRF strength was evaluated using D11 spreader as wedge in an Instron testing machine. Root canals instrumented with ProTaper and 6% Profile instruments showed maximum reduction in CFUs, with statistically insignificant difference between them. The VRF resistance decreased in all instrumented groups. The difference of VRF between 2% and 4% taper Profile groups was statistically insignificant (P = .195). One-way analysis of variance showed that canals instrumented with ProTaper F4 showed maximum reduction in VRF resistance compared with control uninstrumented group. Profile 6% taper instruments offer the advantage of maximum debridement without significant reduction in root fracture resistance. Copyright 2010 Mosby, Inc. All rights reserved.

  9. A novel computer algorithm for modeling and treating mandibular fractures: A pilot study.

    PubMed

    Rizzi, Christopher J; Ortlip, Timothy; Greywoode, Jewel D; Vakharia, Kavita T; Vakharia, Kalpesh T

    2017-02-01

    To describe a novel computer algorithm that can model mandibular fracture repair. To evaluate the algorithm as a tool to model mandibular fracture reduction and hardware selection. Retrospective pilot study combined with cross-sectional survey. A computer algorithm utilizing Aquarius Net (TeraRecon, Inc, Foster City, CA) and Adobe Photoshop CS6 (Adobe Systems, Inc, San Jose, CA) was developed to model mandibular fracture repair. Ten different fracture patterns were selected from nine patients who had already undergone mandibular fracture repair. The preoperative computed tomography (CT) images were processed with the computer algorithm to create virtual images that matched the actual postoperative three-dimensional CT images. A survey comparing the true postoperative image with the virtual postoperative images was created and administered to otolaryngology resident and attending physicians. They were asked to rate on a scale from 0 to 10 (0 = completely different; 10 = identical) the similarity between the two images in terms of the fracture reduction and fixation hardware. Ten mandible fracture cases were analyzed and processed. There were 15 survey respondents. The mean score for overall similarity between the images was 8.41 ± 0.91; the mean score for similarity of fracture reduction was 8.61 ± 0.98; and the mean score for hardware appearance was 8.27 ± 0.97. There were no significant differences between attending and resident responses. There were no significant differences based on fracture location. This computer algorithm can accurately model mandibular fracture repair. Images created by the algorithm are highly similar to true postoperative images. The algorithm can potentially assist a surgeon planning mandibular fracture repair. 4. Laryngoscope, 2016 127:331-336, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  10. The outcome of surgically treated traumatic unstable pelvic fractures by open reduction and internal fixation.

    PubMed

    Mardanpour, Keykhosro; Rahbar, Mahtab

    2013-07-01

    This study was performed to evaluate functional and radiological results of pelvic ring fractures treatment by open reduction and internal fixation. Thirty eight patients with unstable pelvic fractures, treated from 2002 to 2008 were retrospectively reviewed. The mean patients' age was 37 years (range 20 to 67). Twenty six patients were men (4 patients with type B and 22 patients with type C fracture) and 12 women (7 patients with type B and 5 patients with type C fracture). The commonest cause was a road traffic accident (N=37, about 97%). Internal fixation was done by plaque with ilioinguinal and Kocher-Langenbeek approaches for anterior, posterior pelvic wall and acetabulum fracture respectively. Quality of reduction was graded according to Majeed score system. There were 11 type-C and 27 type-B pelvic fractures according to Tile's classification. Thirty six patients sustained additional injuries. The commonest additional injury was lower extremity fracture. The mean follow-up was 45.6 months (range 16 to 84 months).The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients with type B pelvic fractures and functional outcome was excellent in 46%, good in 27%, fair in 27% and poor in 0% of the patients with type C pelvic fractures. There were four postoperative infections. No sexual functional problem was reported. Neurologic problem like Lateral cutaneous nerve of thigh injury recovered completely in 2 patients and partially in 2 patients. There was no significant relation between functional outcome and the site of fracture (P greater than 0.005). Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization. It must be carried out as soon as the general condition of the patient permits, and even up to two weeks.

  11. [Calcaneal fractures treated by open reduction and internal fixation with a locking compression plate (LCP). A prospective study. part I: basic analysis of the group].

    PubMed

    Svatoš, F; Bartoška, R; Skála-Rosenbaum, J; Douša, P; Pacovský, V; Krbec, M

    2011-01-01

    In a prospective study of patients with calcaneal fractures treated by open reduction from an extensile lateral approach and LCP osteosynthesis, the authors evaluated the basic epidemiological data, mechanism of injury, type of fracture, essential data on surgery, days of hospital stay and the number of complications. In the period from September 1, 2006 to July 31, 2010, a total of 230 patients with 243 calcaneal fractures were treated. The fractures were classified as either open or closed and according to the Essex-Lopresti system. Of the total number of patients, 135 (55.6 % of all fractures) were indicated for conservative treatment and 108 (44.4% of all fractures) for surgical intervention. Indications for surgery based on the generally accepted criteria enabled us to select 77 patients with 82 fractures (33.7 % of all fractures) for treatment by the method of open reduction and LCP osteosynthesis. These patients constituted the group evaluated here. The other patients were treated using other techniques (21 fractures, i.e., 8.6 % of all fractures, by the Stehlík-Štulík transfixation method and further five [2.1 %] by screw osteosynthesis). Six surgeons were involved in the treatment of this group. For the diagnosis of fractures, plain radiographs in lateral and axial projection and axial and coronal CT images were used. All fractures were treated after subsidence of oedema by the method of open reduction and LCP fixation from an extensile lateral approach, with the use of a tourniquet. The follow-up period for the evaluation of functional outcome and bone union was 3 to 48 months. Fifty patients were followed up for over one year. The group evaluated comprised 58 men (75.3 %) with 63 fractures (76.8 %) and 19 women (24.7 %) with 19 fractures (23.2 %). The average age of the group was 42 years, with 41 years (range, 22-61 years) in men and 47 years (range, 30-70 years) in women. The most frequent cause of injury was a fall from a height below 1 metre and this was recorded in 38 patients (49.4 %); 18 patients (24.3 %) had a fall from a height below 3 metres. Eight fractures were caused by a fall from the window, seven calcaneal fractures, as part of .polytrauma, were sustained in road accidents (9.1 %) and six calcaneal bones were injured due to ankle sprain in walking on a flat surface (7.8 %). Bilateral fractures occurred in five (6.5 %) patients, the right and left heel bones were injured in 31 (40.3 %) and 41 (53.2 %) fracture cases, respectively. An open fracture was recorded on three occasions (3.7 %). Of the 82 evaluated fractures, 23 were type IIa fractures (28 %) and 59 were type IIb fractures (72 %) according to the Essex-Lopresti classification system. The average injury-surgery interval was 10 days (range, 1 - 23 days). The average operative time was 77 minutes (range, 45-175 min) and the average duration of tourniquet application was 61 minutes (range, 20-130 min). The average length of hospital stay was 18 days (range, 7-61 days). In 15 patients (18.3 % of osteosynthesis cases) wound healing was delayed. Deep wound infection developed in three cases (3.7 %); these required revision surgery which involved implant removal before bone union in two cases and healing of the wound after revision without implant removal in one case. A necrotic lesion in one case (1.2 %) was treated by muscle flap transfer. Complications which varied in type and severity were recorded in 22 % of the patients. The Rowe score was used to evaluate functional outcomes, which were excellent in 44 %, good in 46 %, satisfactory in 4 % and poor in 6 % of the surgically treated patients.. Only about one-third of the patients with calcaneal fractures were indicated for open LCP osteosynthesis. This is in agreement with the strict indication criteria established by the foreign authors with Professors Zwipp and Sanders at the head. It appears that this fracture chiefly occurs in the population of young active men (Kočiš reported only men and no woman with this fracture in his study). The authors focus on exact radiographic diagnosis including CT examination, as recommended by Stehlík and Štulík in their book. They recommend to use the Essex-Lopresti system for primary classification and, because of the frequency of LCP osteosynthesis procedures performed, also recommend to carry out this treatment in specialised institutions. The rate of serious complications in this study was relatively low and in accordance with the findings of Zwipp, Zeman and others. The analysis of basic data on the group of patients with calcaneal fractures treated by open reduction and LCP fixation showed the following: chiefly young active men sustained this fracture; calcaneal fracture was usually due to a fall or jump from a level not too high; X-ray examination (lateral and axial projection) was sufficient to make a diagnosis; for a decision to operate it was useful to complete the diagnosis by CT examination; the prerequisite for minimising post-operative complications was strict adherence to the established indication criteria, surgery only after oedema had subsided and use of the correct surgical technique. The number of complications and their nature did not differ from the data reported by other authors.

  12. [Surgical treatment strategy of the floating shoulder injury].

    PubMed

    Song, Zhe; Xue, Han-Zhong; Li, Zhong; Zhuang, Yan; Wang, Qian; Ma, Teng; Zhang, Kun

    2013-10-18

    To discuss the clinical characteristics and the surgical treatment strategy of the floating shoulder injury. 26 cases with the floating shoulder injury between January 2006 and January 2012 were retrospectively evaluated. There were 15 males and 11 females with an average age of 35.2 (22-60) years. According to Wong's classification of floating shoulder injury: type IA, 3 cases; type IB, 9 cases; type II, 4 cases; type IIIA, 6 cases; type IIIB, 4 cases. All the 26 cases had accepted the surgical treatment. We observed the postoperative fracture reduction, damage repair, fracture healing and internal fixation through the X-ray films. We also evaluated the shoulder function regularly according to the Constant scores and Herscovici evaluation criteria. The 26 cases were followed up for an average of 16.8 (12-24) months.All the fractures healed for a mean time of 2.4 months, the mean Constant score was 89.4 (60-100). The effect of Herscovici evaluation criteria: excellent, 15 cases; good, 8 cases;fair, 3 cases;the excellent rate 88.5%. Open reduction and internal fixation is an effective method for the treatment of floating shoulder injury, but we should select the reset sequence and fixation methods according to the type of fracture and degree of displacement.

  13. Clinical and radiological outcomes of transoral endoscope-assisted treatment of mandibular condylar fractures.

    PubMed

    You, H-J; Moon, K-C; Yoon, E-S; Lee, B-I; Park, S-H

    2016-03-01

    Fractures of the mandibular condyle are one of the most common craniofacial fractures. However, the diagnosis and treatment of these fractures is controversial because of the multiple surgical approaches available. The purposes of this study were to identify surgery-related technical tips for better outcomes and to evaluate the results as well as complications encountered during 7 years of endoscope use to supplement the limited intraoral approach in the treatment of mandibular condylar fractures. Between 2005 and 2012, 50 patients with condylar fractures underwent endoscope-assisted reduction surgery. Postoperative facial bone computed tomography and panoramic radiography demonstrated adequate reduction of the condylar fractures in all patients. No condylar resorption was detected, and most patients displayed a satisfactory functional and structural recovery. There was no facial nerve damage or transitory hypoesthesia, and there were no visible scars after the surgery. Transoral endoscope-assisted treatment is a challenging but reliable method with lower morbidity and a rapid recovery. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Rereduction for Redisplacement of Both-Bone Forearm Shaft Fractures in Children.

    PubMed

    Eismann, Emily A; Parikh, Shital N; Jain, Viral V

    2016-06-01

    There is a high rate of redisplacement after closed reduction and cast treatment of displaced both-bone forearm shaft fractures in children. Little evidence is available on the efficacy of rereduction of these redisplaced fractures. This study evaluates the impact of rereduction on radiographic outcomes and compares the cost to surgical stabilization. This retrospective study included 31 children (mean age, 6.3 y; 18 boys) treated with rereduction for redisplacement of a displaced both-bone forearm shaft fracture between 2008 and 2013. Angulation was measured on anteroposterior and lateral radiographs of the radius and ulna at injury, after reduction, at redisplacement, after rereduction, and at fracture union. Average procedure costs for rereduction and surgical stabilization were calculated. Initial reduction decreased apex volar angulation (initially >20 degrees) of both bones to a median of ≤2 degrees. After an average of 15 days (range, 4 to 35 d), apex volar angulation of the radius worsened to 9 degrees, and apex ulnar angulation worsened to >10 degrees for both bones. For every 5 days after initial reduction, apex ulnar angulation of the radius worsened by 4 degrees. Rereduction reduced apex ulnar and volar angulation of both bones to <5 degrees, which was maintained after cast removal. There were no complications. The average procedure cost for rereduction was $2056 compared with $4589 for surgical stabilization with or without implant removal. Rereduction of both-bone forearm shaft fractures after redisplacement following initial closed reduction had satisfactory radiographic outcomes and is a safe, effective, and less expensive option than surgical stabilization. Level IV-therapeutic.

  15. [Operative treatment for complex tibial plateau fractures].

    PubMed

    Song, Qi-Zhi; Li, Tao

    2012-03-01

    To explore the surgical methods and clinical evaluation of complex tibial plateau fractures resulted from high-energy injuries. From March 2006 to May 2009,48 cases with complex tibial plateau fractures were treated with open reduction and plate fixation, including 37 males and 11 females, with an average age of 37 years (ranged from 18 to 63 years). According to Schatzker classification, 16 cases were type IV, 20 cases type V and 12 cases type VI. All patients were examined by X-ray flim and CT scan. The function of knee joint were evaluated according to postoperative follow-up X-ray and Knee Merchant Rating. Forty-eight patients were followed up with a mean time of 14 months. According to Knee Merchant Rating, 24 cases got excellent results, 16 cases good, 6 cases fair and 2 cases poor. Appropriate operation time, anatomical reduction, suitable bone graft and reasonable rehabilitation exercises can maximally recovery the function of knee joint.

  16. [Intramedullary nailing in diaphyseal clavicle fractures using minimally invasive percutaneous reduction].

    PubMed

    Müller, M; Freude, T; Stöckle, U; Kraus, T M

    2017-02-01

    Closed reduction and intramedullary nailing is common in diaphyseal clavicle fractures. The aim of this report is to demonstrate a surgical method with minimally invasive percutaneous reduction in cases where closed reduction fails. The procedure is associated with good cosmetic results. Percutaneous reduction using two reduction forceps enables intramedullary nailing without an open procedure. Open, multifragmented or non-dislocated fractures, oblique fractures due to postoperative dislocation or shortening risk, fracture having potential to become compound fractures, neurovascular complications, pseudoarthroses. The patient is in beach-chair position. After an incision, the nail is entered from medial, two reduction forceps are mounted percutaneously at the lateral and medial fragment. After reduction the nail is pushed forward into the lateral fragment. Thereby, the fracture hematoma is not disturbed for the most part. Early functional rehabilitation with maximal abduction and anteversion of 90° for 6 weeks. Anatomic reduction can be achieved with mild cosmetic impairment.

  17. Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures.

    PubMed

    Wang, Chen; Xu, Gui-Jun; Han, Zhe; Jiang, Xuan; Zhang, Cheng-Bao; Dong, Qiang; Ma, Jian-Xiong; Ma, Xin-Long

    2015-11-01

    The aim of the study was to introduce a new method for measuring the residual displacement of the femoral head after internal fixation and explore the relationship between residual displacement and osteonecrosis with femoral head, and to evaluate the risk factors associated with osteonecrosis of the femoral head in patients with femoral neck fractures treated by closed reduction and percutaneous cannulated screw fixation.One hundred and fifty patients who sustained intracapsular femoral neck fractures between January 2011 and April 2013 were enrolled in the study. All were treated with closed reduction and percutaneous cannulated screw internal fixation. The residual displacement of the femoral head after surgery was measured by 3-dimensional reconstruction that evaluated the quality of the reduction. Other data that might affect prognosis were also obtained from outpatient follow-up, telephone calls, or case reviews. Multivariate logistic regression analysis was applied to assess the intrinsic relationship between the risk factors and the osteonecrosis of the femoral head.Osteonecrosis of the femoral head occurred in 27 patients (18%). Significant differences were observed regarding the residual displacement of the femoral head and the preoperative Garden classification. Moreover, we found more or less residual displacement of femoral head in all patients with high quality of reduction based on x-ray by the new technique. There was a close relationship between residual displacement and ONFH.There exists limitation to evaluate the quality of reduction by x-ray. Three-dimensional reconstruction and digital measurement, as a new method, is a more accurate method to assess the quality of reduction. Residual displacement of the femoral head and the preoperative Garden classification were risk factors for osteonecrosis of the femoral head. High-quality reduction was necessary to avoid complications.

  18. Elevated temperature crack growth

    NASA Technical Reports Server (NTRS)

    Malik, S. N.; Vanstone, R. H.; Kim, K. S.; Laflen, J. H.

    1987-01-01

    The objective of the Elevated Temperature Crack Growth Program is to evaluate proposed nonlinear fracture mechanics methods for application to hot section components of aircraft gas turbine engines. Progress during the past year included linear-elastic fracture mechanics data reduction on nonlinear crack growth rate data on Alloy 718. The bulk of the analytical work centered on thermal gradient problems and proposed fracture mechanics parameters. Good correlation of thermal gradient experimental displacement data and finite element prediction was obtained.

  19. Combined Microwave Ablation and Cementoplasty in Patients with Painful Bone Metastases at High Risk of Fracture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com; Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com; Fele, Rosa Maria, E-mail: rosellafele@tiscali.it

    2016-01-15

    PurposeTo retrospectively evaluate the effectiveness of computed tomography-guided percutaneous microwave ablation (MWA) and cementoplasty in patients with painful bone metastases at high risk of fracture.Materials and MethodsThirty-five patients with 37 metastatic bone lesions underwent computed tomography-guided MWA combined with cementoplasty (polymethylmethacrylate injection). Vertebrae, femur, and acetabulum were the intervention sites and the primary end point was pain relief. Pain severity was estimated by visual analog scale (VAS) before treatment; 1 week post-treatment; and 1, 6, and 12 months post-treatment. Functional outcome was assessed by improved patient walking ability. Radiological evaluation was performed at baseline and 3 and 12 months post-procedure.ResultsIn all patients, painmore » reduction occurred from the first week after treatment. The mean reduction in the VAS score was 84, 90, 90 % at week 1, month 1, and month 6, respectively. Improved walking ability occurred in 100 and 98 % of cases at the 1- and 6-month functional outcome evaluations, respectively. At the 1-year evaluation, 25 patients were alive, and 10 patients (28 %) had died because of widespread disease. The mean reduction in the VAS score and improvement in surviving patients’ walking ability were 90 and 100 %, respectively. No patients showed evidence of local tumor recurrence or progression and pathological fracture in the treated sites.ConclusionOur results suggest that MWA combined with osteoplasty is safe and effective when treating painful bone metastases at high risk of fracture. The number of surviving patients at the 1-year evaluation confirms the need for an effective and long-lasting treatment.« less

  20. Mid-Term Outcomes After Open Reduction Internal Fixation of Proximal Interphalangeal Joint Dorsal Fracture-Dislocations Through a Volar, Shotgun Approach and a Review of the Literature

    PubMed Central

    Giugale, Juan Marcelo; Wang, Juntian; Kaufmann, Robert A.; Fowler, John R.

    2017-01-01

    Background: Proximal interphalangeal (PIP) fracture dislocations remain a complex injury pattern to treat. There are several treatment methods available aimed to restore stability, preserve range of motion, and reconstitute the articular surface. This study looked at the mid-term clinical and radiographic results of open reduction internal fixation through a shotgun approach of comminuted PIP fracture dislocations. Methods: A retrospective review was conducted of all PIP fracture dislocations treated through a volar, shotgun approach at a single institution over a 15-year period. Patients identified were contacted and asked to return to the office for clinical and radiographic evaluation. Patient reported outcomes were assessed with the Michigan hand questionnaire (MHQ) and visual analog scale (VAS) for pain. Results: 5 patients returned to the office for further evaluation with average follow-up of 69 months (range, 33-133 months). 3 patients were found to have post traumatic arthritis on radiographs. 1 case had recurrent instability and one case had a deep infection, both necessitating further surgical intervention. Average PIP arc of motion was found to be 79°. Average VAS score of 0 and MHQ result of 95 (out of a possible score of 100) indicating no residual pain and excellent functionality of the affected hand. Conclusion: Open reduction internal fixation of comminuted PIP fracture dislocations utilizing the volar, shotgun approach provides excellent mid-term functional results despite the high incidence of post traumatic arthritis. PMID:29151999

  1. [Clinical observation on the different treatments targeted at different types of radial head fracture and radial neck fracture].

    PubMed

    Zhang, Ying-Ze; Guo, Ming-Ke; Zheng, Zhan-le; Zhang, Qi; Chen, Wei

    2009-06-15

    To assess the effect of the different treatments targeted at different types of radial head fracture and radial neck fracture. A retrospective study was performed in 87 patients from February 2006 to March 2007. Fifty-four patients with radial head fractures included 36 males and 18 females, aged from 18 to 65 years (the average age was 33); Forty of them resulted from crashing, 8 from traffic injury and 6 from falling injury. According to Mason classification system, there were 15 type I, 23 type II and 16 type III. Thirty-three patients with radial neck fractures included 21 males and 12 females, aged from 9 to 17 years (the average age was 13), 29 of them resulted from crashing, 1 from traffic injury and 3 from falling injury. According to O'Brien classification system, there were 8 type I, 14 type II and 11 type III. Type I of radial head fractures and radial neck fractures were immobilization with cast, the patients with type II of radial head fractures were treated with open reduction and micro-screw or T-trapezoid and bridge-shaped plate fixation and type III had operations to fix with bridge-shaped locked plate and repair the broken annular ligament, or replace heads with prosthesis. All patients with type II and type III of radial neck fractures were treated with closed reduction by leverage and percutaneous intra-medullary nailing. The patients were followed up for 4-12 months (mean 7.2 months). The functional recovery degrees were evaluated with Wheeler's evaluation system. In group of radial head fractures, the results were excellent in 26 patients, good in 20, fair in 6 and poor in 2, the excellent and good rate was 85.2%. In group of radial neck fractures, the results were excellent in 20 patients, good in 9, fair in 4 and poor in no patient, and the excellent and good rate was 87.9%. Different types of fractures should choose different surgical methods according to their characters. The excellent functional recovery depend on anatomical reduction, retaining the head of radius, early repairing and protecting the broken annular ligament of radius, and early functional training.

  2. Surgery versus conservative treatment in patients with type A distal radius fractures, a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Fractures of the distal radius are common and account for an estimated 17% of all fractures diagnosed. Two-thirds of these fractures are displaced and require reduction. Although distal radius fractures, especially extra-articular fractures, are considered to be relatively harmless, inadequate treatment may result in impaired function of the wrist. Initial treatment according to Dutch guidelines consists of closed reduction and plaster immobilisation. If fracture redisplacement occurs, surgical treatment is recommended. Recently, the use of volar locking plates has become more popular. The aim of this study is to compare the functional outcome following surgical reduction and fixation with a volar locking plate with the functional outcome following closed reduction and plaster immobilisation in patients with displaced extra-articular distal radius fractures. Design This single blinded randomised controlled trial will randomise between open reduction and internal fixation with a volar locking plate (intervention group) and closed reduction followed by plaster immobilisation (control group). The study population will consist of all consecutive adult patients who are diagnosed with a displaced extra-articular distal radius fracture, which has been adequately reduced at the Emergency Department. The primary outcome (functional outcome) will be assessed by means of the Disability Arm Shoulder Hand Score (DASH). Secondary outcomes comprise the Patient-Rated Wrist Evaluation score (PRWE), quality of life, pain, range of motion, radiological parameters, complications and cross-overs. Since the treatment allocated involves a surgical procedure, randomisation status will not be blinded. However, the researcher assessing the outcome at one year will be unaware of the treatment allocation. In total, 90 patients will be included and this trial will require an estimated time of two years to complete and will be conducted in the Academic Medical Centre Amsterdam and its partners of the regional trauma care network. Dicussion Ideally, patients would be randomised before any kind of treatment has been commenced. However, we deem it not patient-friendly to approach possible participants before adequate reduction has been obtained. Trial registration This study is registered at the Netherlands Trial Register (NTR3113) and was granted permission by the Medical Ethical Review Committee of the Academic Medical Centre on 01-10-2012. PMID:24642190

  3. Cerclage wire and lag screw fixation of the lateral malleolus in supination and external rotation fractures of the ankle.

    PubMed

    Bajwa, Amarjit S; Gantz, D E

    2005-01-01

    Wound dehiscence and exposed lateral hardware can occur after open reduction internal fixation of lateral malleolus. The bulk of a lateral plate and the minimum soft tissue over the lateral malleolus may contribute to this situation. The objective of this study was to evaluate a series of patients with lateral malleolar fractures treated with operative reduction using minimal hardware. We wanted to observe whether there was any loss of reduction and whether there were any incidences of soft tissue disruption. Fifty-two patients with long spiral fracture of the lateral malleolus in a supination-external rotation injury were treated with two or three 3.5-mm lag screws inserted 1 cm apart and 1 or 2 circlage wires. Less rigid fixation was supplemented with a below-the-knee plaster cast. All patients were followed up until clinical and radiological evidence of fracture healing at 6, 10, and 14 weeks postoperatively. By 10 weeks, all patients were full weight bearing, although most patients still limped. At 14 weeks' follow-up, there were no infections or wound dehiscences. All patients were able to return to their activities of daily living. All the fractures had united without loss of original position. Two fractures of the posterior bone spikes seen during surgery united uneventfully. Long spiral fractures of the lateral malleolus of the ankle can be treated successfully with 2 or 3 lag screws and circlage wires without compromising the outcome of the fracture healing.

  4. Planning acetabular fracture reduction using patient-specific multibody simulation of the hip

    NASA Astrophysics Data System (ADS)

    Oliveri, Hadrien; Boudissa, Mehdi; Tonetti, Jerome; Chabanas, Matthieu

    2017-03-01

    Acetabular fractures are a challenge in orthopedic surgery. Computer-aided solutions were proposed to segment bone fragments, simulate the fracture reduction or design the osteosynthesis fixation plates. This paper addresses the simulation part, which is usually carried out by freely moving bone fragments with six degrees of freedom to reproduce the pre-fracture state. Instead we propose a different paradigm, closer to actual surgeon's requirements: to simulate the surgical procedure itself rather than the desired result. A simple, patient-specific, biomechanical multibody model is proposed, integrating the main ligaments and muscles of the hip joint while accounting for contacts between bone fragments. Main surgical tools and actions can be simulated, such as clamps, Schanz screws or traction of the femur. Simulations are computed interactively, which enables clinicians to evaluate different strategies for an optimal surgical planning. Six retrospective cases were studied, with simple and complex fracture patterns. After interactively building the models from preoperative CT, gestures from the surgical reports were reproduced. Results of the simulations could then be compared with postoperative CT data. A qualitative study shows the model behavior is excellent and the simulated reductions fit the observed data. A more quantitative analysis is currently being completed. Two cases are particularly significant, for which the surgical reduction actually failed. Simulations show it was indeed not possible to reduce these fractures with the chosen approach. Had our simulator being used, a better planning may have avoided a second surgery to these patients.

  5. Effectiveness of a two-step population-based osteoporosis screening program using FRAX: the randomized Risk-stratified Osteoporosis Strategy Evaluation (ROSE) study.

    PubMed

    Rubin, K H; Rothmann, M J; Holmberg, T; Høiberg, M; Möller, S; Barkmann, R; Glüer, C C; Hermann, A P; Bech, M; Gram, J; Brixen, K

    2018-03-01

    The Risk-stratified Osteoporosis Strategy Evaluation (ROSE) study investigated the effectiveness of a two-step screening program for osteoporosis in women. We found no overall reduction in fractures from systematic screening compared to the current case-finding strategy. The group of moderate- to high-risk women, who accepted the invitation to DXA, seemed to benefit from the program. The purpose of the ROSE study was to investigate the effectiveness of a two-step population-based osteoporosis screening program using the Fracture Risk Assessment Tool (FRAX) derived from a self-administered questionnaire to select women for DXA scan. After the scanning, standard osteoporosis management according to Danish national guidelines was followed. Participants were randomized to either screening or control group, and randomization was stratified according to age and area of residence. Inclusion took place from February 2010 to November 2011. Participants received a self-administered questionnaire, and women in the screening group with a FRAX score ≥ 15% (major osteoporotic fractures) were invited to a DXA scan. Primary outcome was incident clinical fractures. Intention-to-treat analysis and two per-protocol analyses were performed. A total of 3416 fractures were observed during a median follow-up of 5 years. No significant differences were found in the intention-to-treat analyses with 34,229 women included aged 65-80 years. The per-protocol analyses showed a risk reduction in the group that underwent DXA scanning compared to women in the control group with a FRAX ≥ 15%, in regard to major osteoporotic fractures, hip fractures, and all fractures. The risk reduction was most pronounced for hip fractures (adjusted SHR 0.741, p = 0.007). Compared to an office-based case-finding strategy, the two-step systematic screening strategy had no overall effect on fracture incidence. The two-step strategy seemed, however, to be beneficial in the group of women who were identified by FRAX as moderate- or high-risk patients and complied with DXA.

  6. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    PubMed

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  7. [Minimally invasive percutaneous plate osteosynthesis versus open reduction and internal fixation for distal tibial fractures in adults: a meta-analysis].

    PubMed

    Zhang, Qing-xi; Gao, Fu-qiang; Sun, Wei; Wang, Yun-ting; Yang, Yu-run; Li, Zirong

    2015-08-01

    To perform a meta-analysis on clinical outcomes of minimally invasive percutaneous plate osteosynthesis (MIPPO) or open reduction and internal fixation (ORIF) for distal tibial fractures in adults. Pubmed database (from 1968 to March 2014), Cochrane library and CNKI database (from 1998 to March 2014) were searched. Case-control study on minimally invasive percutaneous plate osteosynthesis (MIPPO) or open reduction and internal fixation (ORIF) for distal tibial fractures in adults were chosen,and postoperative infection, operative time, blood loss, fracture nonunion rate, delayed union,fracture malunion rate were seen as evaluation index for meta analysis. The system review was performed using the method recommended by the Cochrane Collaboration. Totally 5 studies (366 patients) were enrolled. Meta-analysis showed that there were significant meaning in postoperative infection between MIPPO and ORIF [OR = 0.23,95% CI (0.06,0.92), P = 0.04]; fracture nonunion rate in MIPPO was lower than in ORIF group [OR = 0.16, 95% CI (0.03,0.76), P = 0.02]; operative time in MIPPO was shorter than in ORIF group, and had significant difference [MD = -14.42, 95% CI (-27.79, -1.05), P < 0.05]; blood loss in MIPPO was less than in ORIF group [MD= -87.17,95%CI (-99.20, -75.15), P < 0.05]; there was no obviously meaning in delayed union between two groups. For distal tibial fractures in adults, MIPPO has, advantages of short operative time, less blood loss, lower incidence of infection and fracture non-uniom, but with high fracture malunion rate. MIPPO for distal tibial fractures in adults is better than ORIF, and the best treatment should choose according to patient's condition.

  8. [Therapeutic observation of subcutaneous pedicle screw-rod system with modified placement for Tile B pelvic fractures].

    PubMed

    Wu, Xiao-Tian; Chen, Nong; Pan, Fu-Gen; Liu, Zuo-Qing; He, Xiao-Jian

    2017-03-25

    To investigate the feasibility and therapeutic effect of subcutaneous pedicle screw-rod system with modified placement in treatment of Tile B pelvic fractures. From June 2014 to August 2015, 14 patients with Tile B pelvic fractures were treated by subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle. There were 8 males and 6 females, aged from 23 to 65 years with an average of 42 years. Operative time, intraoperative blood loss, fracture healing and postoperative complication were observed and clinical effects were evaluated by Matta reduction standard and Majeed score. All patients were followed up from 8 to 15 months with an average of 10.5 months. Operative time was 25 to 45 min with an average of 32 min;intraoperative blood loss was 10 to 35 ml with an average of 18 ml. All fractures got primary healing and healed time was 9 to 14 weeks with an average of 12.5 weeks. No postoperative incision infection, internal fixation failure and ectopic ossification were found, 4 cases occurred unilateral lateral femoral cutaneous nerve injury and 1 case occurred unilateral femoral nerve paralysis, but all restored finally. According to Matta criteria, reduction was excellent in 7 cases, good in 5 cases, fair in 2 case. According to Majeed score system, the functional evaluation at last follow-up was excellent in 5 cases, good in 7 cases, fair in 2 cases with the average score of 81.50±8.05. Subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle have advantages of strong reduction, less trauma and complications, and is a promising surgical method in the treatment of Tile B pelvic fractures.

  9. Patient satisfaction after open reduction and internal fixation through lateral extensile approach in displaced intraarticular calcaneal fractures (Sander's type II and III).

    PubMed

    Kavin, Khatri; Vijay, Sharma; Devendra, Lakhotia; Kamran, Farooque

    2016-01-01

    To determine patient satisfaction in the patients of displaced intraarticular calcaneal fractures treated with standard lateral approach. The patients of displaced calcaneal fractures (Sander's type II and III) treated between March 2009 and March 2012 were included in the retrospective review and functional outcome was evaluated using American Orthopaedic Foot and Ankle Society (AOFAS) hind foot score, Creighton Nebraska Health Foundation Assessment (CNHFA) scale and foot function index (FFI). The cohort included 26 patients (19 males: seven were females) with a mean age of 38.16 ± 13.53 years (range 18-64 years). The mean period of follow-up was 24.42 ± 6.68 months. The patients achieved good functional scores after anatomical reduction of the fracture. The complication rate was low following strict inclusion criteria. Careful patient selection in displaced intraarticular calcaneal fractures treated through lateral extensile approach achieves good patient satisfaction.

  10. Role for Primary Repair of Deltoid Ligament Complex in Ankle Fractures.

    PubMed

    Rigby, Ryan B; Scott, Ryan T

    2018-04-01

    Acute deltoid injuries may occur with ankle fractures. They are often left to heal without repair, possibly leading to chronic medial ankle instability. Stress radiographs identify the need for surgical repair of fractures or soft tissue damage. Gravity stress views have benefits over manually stressing the ankle. MRI can explore the extent of medial soft tissue injuries. Arthroscopy can evaluate and potentially treat deltoid injuries. Interposition of the deltoid may preclude adequate fracture reduction. Except with deltoid tear, fractures should be reduced and fixated, then the deltoid assessed. With persistent instability, primary repair may prevent long-term sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Transmasseteric anterior parotid approach for condylar fractures: experience of 129 cases.

    PubMed

    Narayanan, Vinod; Ramadorai, Ashok; Ravi, Poornima; Nirvikalpa, Natarajan

    2012-07-01

    We have evaluated the transmasseteric anterior parotid (TMAP) approach in the treatment of 163 condylar fractures in 129 patients. Ninety-five patients presented with unilateral, and 34 with bilateral, fractures. The inclusion criteria were patient's choice for open reduction and internal fixation, displaced unilateral condylar fractures with occlusal derangement, and displaced bilateral condylar fractures with anterior open bite. Mean (SD) maximum interincisal opening after 3 months was 44(5)mm. There were no differences in lateral movements during the reviews 6 weeks and 3 months postoperatively. Protrusive movement at the end of 3 months was 7(2)mm. All patients achieved functional occlusion identical to the pretraumatic occlusion and good reduction of the condyles. No patient developed temporary or permanent facial palsy, sialocele, salivary fistula, or Frey syndrome. The mean (SD) operating time was 46(11)min. The TMAP approach avoids the complications of incision of the parotid gland, minimises the risk of facial nerve palsy, and offers excellent access to the fractured condyle. Copyright © 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Treatment of subtalar calcanean fractures using trans-osseous limited lateral approach.

    PubMed

    Ragab, Abdelaleem H; Mubark, Islam M; Nagi, Ahmed M; Abdelnaby, Mohamed Aly

    2014-01-01

    Calcaneal fractures are the most common fractures of the tarsal bones. The majority of these fractures are produced by axial force like a fall from a height. Controversy still exists on the best line of treatment. This study is to evaluate the results of trans-osseous limited lateral approach as a minimally invasive surgical treatment of the displaced intra-articular calcaneal fractures. The study included forty two patients (46 feet) with displaced intra-articular calcaneal fractures admitted to El-Hadra University Hospital. They were treated by trans-osseous open reduction of subtalar joint and internal fixation by k-wires consuming the trans-osseous limited lateral approach. Out of 42 patients, 36 pateints (85.7%) were males. Using calcaneal fracture scoring system, the mean score was 67.55+17.35. Satisfactory results were found in 26 patients (61.9%), while 16 patients (38.1%) had unsatisfactory results. There was significant relationship between classification of the fracture and the final results (the more the grade of the fracture, the worse the final score) (x 2 =5.914, p=0.05). The value of calcaneal angles were significantly improved after surgery including bohler angle (p=0.0001), gissane angle (p=0.0001), calcaneal pitch angle (p=0.001) and calcaneofibular space (p=0.0021). 1. Trans-osseous limited lateral approach is an effective method for management of intra articular calcaneal fractures. 2. Anatomical reduction for intra articular calcaneal fractures is essential. 3. Functional outcome of intra articular calcaneal fractures depends upon the initial damage of the articular cartilage. 4. There is a need for multi-center prospective randomized study for accurate assessment of the results of operative management of intra articular calcaneal fractures involving pre and post-operative CT for assessment of reduction and using a rational scoring system and a long period of follow up.

  13. The effect of the Tscherne injury pattern on the outcome of operatively treated Lisfranc fracture dislocations.

    PubMed

    Demirkale, Ismail; Tecimel, Osman; Celik, Ismail; Kilicarslan, Kasim; Ocguder, Ali; Dogan, Metin

    2013-09-01

    Lisfranc fracture dislocations cause severe tarso-metatarsal malalignment. The research question of this study was to evaluate the severity of the soft tissue injury on the final clinical outcome and compare that with the effect of various determinants on the disability in daily living activities after open reduction and internal fixation of a Lisfranc injury. This study consisted of a retrospective analysis of patients with Lisfranc fracture dislocations who were treated by open reduction and internal fixation beween 2004 and 2009. Evaluation focused mainly on the severity of the soft tissue injury, age, fracture classification, time to operation, posttraumatic osteoarthritis, and the results were compared with American Foot and Ankle Society (AOFAS) scores, and Foot and Ankle Disability Index (FADI). Eight patients had Tscherne Grade 1, 13 had Grade 2, and 11 had Grade 3 soft tissue injuries. Myerson classification revealed 11 type A, 8 type B and 13 type C fractures. Six patients' operations were delayed beyond 8h. Of the 38 patients treated in the study period, 32 patients (11 female, 21 male; <30 y-old: 14, >30 y-old: 18) were available for complete follow-up (average, 55.5 months). The comparison of treatment results revealed that those patients with high grade soft tissue injuries had lower AOFAS and FADI scores (43.8±15.9, 53.7±9.4, respectively) when compared to Tscherne Grade 1 injuries (82.8±6.1, 109±13.9, respectively) (p<0.001). The overall negative impact of the severity of soft tissue injury on functional outcomes had similar significance with regard to post-traumatic osteoarthritis, and fracture type. There was also a statistically significant difference between outcome measures and post-reduction quality (p=0.002). Patient age (p=0.9) and delayed surgery (p=0.5) had no statistically significant effect on the final outcome. Satisfactory results can be achieved with open reduction for Lisfranc injuries. However, despite this treatment, both the severity of the soft tissue injury and non-anatomic reduction are negative prognostic factors in the treatment of Lisfranc fracture dislocations. Copyright © 2013 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  14. Treatment for proximal humeral fractures with percutaneous plating: our first results.

    PubMed

    Imarisio, D; Trecci, A; Sabatini, L; Scagnelli, R

    2013-06-01

    Proximal humeral fractures are common lesions; there is no generally accepted strategy about the treatment for displaced and unstable two- to four-part fractures. We have nowadays many different surgical solutions, ranging from percutaneous pinning to shoulder arthroplasty. Percutaneous plating can be a good solution to treat some of these fractures using a minimally invasive technique and performing stable fixation that can allow early mobilization. Purpose of this paper is to evaluate the results of our first cases of percutaneous plating in proximal humeral fractures in order to assess the theoretical advantages and the incidence of possible complications. From June 2009 to February 2012, we treated 29 proximal humeral fractures with a percutaneous plating (NCB-PH plate) through an anterolateral deltoid split. For each patient, we evaluated the clinical outcome according to Constant score and the radiographic results, paying attention to fracture healing, loss of reduction, hardware complications, and head necrosis. The clinical evaluation gave a mean Constant score value of 79 points. Comparing each value to the unaffected shoulder, we could find these results: 7 excellent, 10 good, 8 fair, and 4 poor. No axillary nerve lesions were clinically detected. The radiographic evaluation showed a complete bone healing in all cases within the first 3 months. No head necrosis was detected, as well as screws loosening. In two cases, the X-ray at 2 months revealed a little loss of reduction in varus. Two patients had an anterior pain; in one of these two cases, the plate was removed. In our series, we had no cases of head necrosis, screws cutout, fracture collapse, hardware mobilization, and we think this could be the real advantage of the percutaneous technique compared to the open one, thanks to the reduced biological damage. We had some poor results, related more to patient's age than to other factors. The safety of the technique for the axillary nerve is demonstrated in the literature and confirmed by our experience. Percutaneous plating of proximal humeral fractures with NCB-PH plate has demonstrated to be a good strategy in managing these lesions without increasing complications.

  15. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    PubMed

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland-Altman plot, there were no statistical significant difference (P<0.05). Images from the sonography could provide visualization of the fracture during reduction and MIPO as accurately as the radiography. Thus, the sonography assisted MIPO in femoral shaft fracture can be done effectively comparing with radiographic assisted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Liquid metal embrittlement of T91 and 316L steels by heavy liquid metals: A fracture mechanics assessment

    NASA Astrophysics Data System (ADS)

    Auger, T.; Hamouche, Z.; Medina-Almazàn, L.; Gorse, D.

    2008-06-01

    LME of the martensitic T91 and the austenitic 316L steels have been investigated in the CCT geometry in the plane-stress condition. Using such a geometry, premature cracking induced by a liquid metal (PbBi and Hg) can be studied using a fracture mechanics approach based on CTOD, J-Δ a and fracture assessment diagram. One is able to measure a reduction of the crack tip blunting and a reduction of the energy required for crack propagation induced by the liquid metal. In spite of some limitations, this qualitative evaluation shows that liquid metals do not induce strong embrittlement on steels in plane-stress condition. Rather, the effect of the liquid metal seems to promote a fracture mode by plastic collapse linked with strain localization. It indicates that the materials, in spite of a potential embrittlement, should still be acceptable in terms of safety criteria.

  17. A simulation trainer for complex articular fracture surgery.

    PubMed

    Yehyawi, Tameem M; Thomas, Thaddeus P; Ohrt, Gary T; Marsh, J Lawrence; Karam, Matthew D; Brown, Thomas D; Anderson, Donald D

    2013-07-03

    The purposes of this study were (1) to develop a physical model to improve articular fracture reduction skills, (2) to develop objective assessment methods to evaluate these skills, and (3) to assess the construct validity of the simulation. A surgical simulation was staged utilizing surrogate tibial plafond fractures. Multiple three-segment radio-opacified polyurethane foam fracture models were produced from the same mold, ensuring uniform surgical complexity between trials. Using fluoroscopic guidance, five senior and seven junior orthopaedic residents reduced the fracture through a limited anterior window. The residents were assessed on the basis of time to completion, hand movements (tracked with use of a motion capture system), and quality of the obtained reduction. All but three of the residents successfully reduced and fixed the fracture fragments (one senior resident and two junior residents completed the reduction but were unsuccessful in fixating all fragments). Senior residents had an average time to completion of 13.43 minutes, an average gross articular step-off of 3.00 mm, discrete hand motions of 540 actions, and a cumulative hand motion distance of 79 m. Junior residents had an average time to completion of 14.75 minutes, an average gross articular step-off of 3.09 mm, discrete hand motions of 511 actions, and a cumulative hand motion distance of 390 m. The large difference in cumulative hand motion distance, despite comparable numbers of discrete hand motion events, indicates that senior residents were more precise in their hand motions. The present experiment establishes the basic construct validity of the simulation trainer. Further studies are required to demonstrate that this laboratory-based model for articular fracture reduction training, along with an objective assessment of performance, can be used to improve resident surgical skills.

  18. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    PubMed Central

    Al-Sadek, Tabet A.; Niklev, Desislav; Al-Sadek, Ahmed

    2016-01-01

    BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with “Talwarkar” square nails which is also again a simple method with better results than conservative methods. PMID:28028411

  19. Analysis of facial bone fractures: An 11-year study of 2,094 patients

    PubMed Central

    Hwang, Kun; You, Sun Hye

    2010-01-01

    Purpose: The medical records of these patients were reviewed and analysed to determine the clinical characteristics and treatment of facial bone fractures. Patients and Methods: This is a retrospective study of 2,094 patients with facial bone fractures from various accidents that were treated at the Inha University Hospital from 1996 to 2007. Results: The most common age group was the third decade of life (29%). Males were more common than females (3.98:1). The most common aetiology was violent assault or nonviolent traumatic injury (49.4%). The most common isolated fracture site was the nasal bone (37.7%), followed by the mandible (30%), orbital bones (7.6%), zygoma (5.7%), maxilla (1.3%) and the frontal bone (0.3%). The largest group with complex fractures included the inferior region of the orbital floor and zygomaticomaxilla (14%). Closed reduction was performed in 46.3% of the cases while 39.7% of the cases required open reduction. For open reductions, the most commonly used soft-tissue approach was the intraoral approach (32.3%). The complication rate was 6.4% and the most common complication was hypoesthesia (68.4%) followed by diplopia (25.6%). Conclusion: Long-term collection of epidemiological data regarding facial fractures and concomitant injuries is important for the evaluation of existing preventive measures and useful in the development of new methods of injury prevention and treatment. PMID:20924449

  20. Temporary short-segment pedicle screw fixation for thoracolumbar burst fractures: comparative study with or without vertebroplasty.

    PubMed

    Aono, Hiroyuki; Ishii, Keisuke; Tobimatsu, Hidekazu; Nagamoto, Yukitaka; Takenaka, Shota; Furuya, Masayuki; Chiaki, Horii; Iwasaki, Motoki

    2017-08-01

    Short-segment posterior spinal instrumentation for thoracolumbar burst fracture provides superior correction of kyphosis by an indirect reduction technique, but it has a high failure rate. The purpose of the study we report here was to compare outcomes for temporary short-segment pedicle screw fixation with vertebroplasty and for such fixation without vertebroplasty. This is a prospective multicenter comparative study. We studied 62 consecutive patients with thoracolumbar burst fracture who underwent short-segment posterior instrumentation using ligamentotaxis with Schanz screws with or without vertebroplasty. Radiological parameters (Cobb angle on standing lateral radiographs) were used. Implants were removed approximately 1 year after surgery. Neurologic function, kyphotic deformity, canal compromise, and fracture severity were evaluated prospectively. After surgery, all patients with neurologic deficit had improvement equivalent to at least one grade on the American Spinal Injury Association impairment scale and had fracture union. Kyphotic deformity was reduced significantly, and reduction of the vertebrae was maintained with and without vertebroplasty, regardless of load-sharing classification. Although no patient required additional anterior reconstruction, kyphotic change was observed at disc level mainly after implant removal with or without vertebroplasty. Temporary short-segment fixation yielded satisfactory results in the reduction and maintenance of fractured vertebrae with or without vertebroplasty. Kyphosis recurrence may be inevitable because adjacent discs can be injured during the original trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Application of 3D printed customized external fixator in fracture reduction.

    PubMed

    Qiao, Feng; Li, Dichen; Jin, Zhongmin; Gao, Yongchang; Zhou, Tao; He, Jinlong; Cheng, Li

    2015-01-01

    Long bone fracture is common in traumatic osteopathic patients. Good reduction is beneficial for bone healing, preventing the complications such as delayed union, nonunion, malunion, but is hard to achieve. Repeated attempts during the surgery would increase the operation time, cause new damage to the fracture site and excessive exposure to radiation. Robotic and navigation techniques can help improve the reduction accuracy, however, the high cost and complexity of operation have limited their clinical application. We combined 3D printing with computer-assisted reduction technique to develop a customised external fixator with the function of fracture reduction. The original CT data obtained by scanning the fracture was imported to computer for reconstructing and reducing the 3D image of the fracture, based on which the external fixator (named as Q-Fixator) was designed and then fabricated by 3D printing techniques. The fracture reduction and fixation was achieved by connecting the pins inserted in the bones with the customised Q-Fixator. Experiments were conducted on three fracture models to demonstrate the reduction results. Good reduction results were obtained on all three fractured bone models, with an average rotation of 1.21°(± 0.24), angulation of 1.84°(± 0.28), and lateral displacement of 2.22 mm(± 0.62). A novel customised external fixator for long bone fracture reduction was readily developed using 3D printing technique. The customised external fixator had the advantages of easy manipulation, accurate reduction, minimally invasion and experience-independence. Future application of the customised external fixator can be extended to include the fixation function with stress adjustment and potentially optimise the fracture healing process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. High Incidence of Vertebral Fractures in Children with Acute Lymphoblastic Leukemia 12 Months After the Initiation of Therapy

    PubMed Central

    Alos, Nathalie; Grant, Ronald; Ramsay, Timothy; Halton, Jacqueline; Cummings, Elizabeth A.; Miettunen, Paivi M.; Abish, Sharon; Atkinson, Stephanie; Barr, Ronald; Cabral, David A.; Cairney, Elizabeth; Couch, Robert; Dix, David B.; Fernandez, Conrad V.; Hay, John; Israels, Sara; Laverdière, Caroline; Lentle, Brian; Lewis, Victor; Matzinger, MaryAnn; Rodd, Celia; Shenouda, Nazih; Stein, Robert; Stephure, David; Taback, Shayne; Wilson, Beverly; Williams, Kathryn; Rauch, Frank; Siminoski, Kerry; Ward, Leanne M.

    2014-01-01

    Purpose Vertebral fractures due to osteoporosis are a potential complication of childhood acute lymphoblastic leukemia (ALL). To date, the incidence of vertebral fractures during ALL treatment has not been reported. Patient and Methods We prospectively evaluated 155 children with ALL during the first 12 months of leukemia therapy. Lateral thoracolumbar spine radiographs were obtained at baseline and 12 months. Vertebral bodies were assessed for incident vertebral fractures using the Genant semi-quantitative method, and relevant clinical indices such as spine bone mineral density (BMD), back pain and the presence of vertebral fractures at baseline were analyzed for association with incident vertebral fractures. Results Of the 155 children, 25 (16%, 95% Confidence Interval (CI) 11% to 23%) had a total of 61 incident vertebral fractures, of which 32 (52%) were moderate or severe. Thirteen of the 25 children with incident vertebral fractures (52%) also had fractures at baseline. Vertebral fractures at baseline increased the odds of an incident fracture at 12 months by an odds ratio of 7.3 (95% CI 2.3 to 23.1, p = 0.001). In addition, for every one standard deviation reduction in spine BMD Z-score at baseline, there was 1.8-fold increased odds of incident vertebral fracture at 12 months (95% CI 1.2 to 2.7, p = 0.006). Conclusion Children with ALL have a high incidence of vertebral fractures after 12 months of chemotherapy, and the presence of vertebral fractures and reductions in spine BMD Z-scores at baseline are highly associated clinical features. PMID:22734031

  3. Functional outcome of Schatzker type V and VI tibial plateau fractures treated with dual plates

    PubMed Central

    Prasad, G Thiruvengita; Kumar, T Suresh; Kumar, R Krishna; Murthy, Ganapathy K; Sundaram, Nandkumar

    2013-01-01

    Background: Dual plate fixation in comminuted bicondylar tibial plateau fractures remains controversial. Open reduction and internal fixation, specifically through compromised soft tissues, has historically been associated with major wound complications. Alternate methods of treatment have been described, each with its own merits and demerits. We performed a retrospective study to evaluate the functional outcome of lateral and medial plate fixation of Schatzker type V and VI fractures through an anterolateral approach, and a medial minimally invasive approach or a posteromedial approach. Materials and Methods: We treated 46 tibial plateau fractures Schatzker type V and VI with lateral and medial plates through an anterolateral approach and a medial minimal invasive approach over an 8 years period. Six patients were lost to followup. Radiographs in two planes were taken in all cases. Immediate postoperative radiographs were assessed for quality of reduction and fixation. The functional outcome was evaluated according to the Oxford Knee Score criteria on followup. Results: Forty patients (33 men and 7 women) who completed the followup were included in the study. There were 20 Schatzker type V fractures and 20 Schatzker type VI fractures. The mean duration of followup was 4 years (range 1-8 years). All patients had a satisfactory articular reduction defined as ≤2 mm step-off or gap as assessed on followup. All patients had a good coronal and sagittal plane alignment, and articular width as assessed on supine X-rays of the knee in the anteroposterior (AP) and lateral views. The functional outcome, as assessed by the Oxford Knee Score, was excellent in 30 patients and good in 10 patients. All patients returned to their pre-injury level of activity and employment. There were no instances of deep infection. Conclusions: Dual plate fixation of severe bicondylar tibial plateau fractures is an excellent treatment option as it provides rigid fixation and allows early knee mobilization. Careful soft tissue handling and employing minimal invasive techniques minimizes soft tissue complications. PMID:23682182

  4. Application of an innovative computerized virtual planning system in acetabular fracture surgery: A feasibility study.

    PubMed

    Wang, Huixiang; Wang, Fang; Newman, Simon; Lin, Yanping; Chen, Xiaojun; Xu, Lu; Wang, Qiugen

    2016-08-01

    Acetabular fracture surgery is amongst the most challenging tasks in the field of trauma surgery and careful preoperative planning is crucial for success. The aim of this paper is to describe the preliminary outcome of the utilization of an innovative computerized virtual planning system for acetabular fractures. 3D models of acetabular fractures and surrounding soft tissues from six patients were constructed from preoperative CT scans. A novel highly-automatic segmentation technique was performed on the 3D model to separate each fracture fragment, then 3D virtual reduction was performed. Additionally, the models were used to assess potential surgical approaches with reference to both the fracture and the surrounding soft tissues. The time required for virtual planning was recorded. After surgery, the virtual plan was compared to the real surgery with respect to surgical approach and reduction sequence. A Likert scale questionnaire was completed by the surgeons to evaluate their satisfaction with the system. Virtual planning was successfully completed in all cases. The planned surgical approach was followed in all cases with the planned reduction sequence followed completely in five cases and partially in one. The mean time required for virtual planning was 38.7min (range 21-57, SD=15.5). The mean time required for planning of B-type fractures was 25.0min (range 21-30, SD=4.6), of C-type fracture 52.3min (range 49-57, SD=4.2). The results of the questionnaire demonstrated a high level of satisfaction with the planning system. This study demonstrates that the virtual planning system is feasible in clinical settings with high satisfaction and acceptability from the surgeons. It provides a viable option for the planning of acetabular fracture surgery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    PubMed

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P < 0.05). The incision length in trial group was significantly shorter than that in control group (P < 0.05). Difference was not significant in operation time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without opening joint capsule can avoid joint stiffness and obtain better joint function.

  6. Open Reduction in Pediatric Condylar Fracture.

    PubMed

    Barbosa, Alexandre Agostini; Mariano, Ronaldo Célio

    2017-05-01

    Facial fractures in children are rare. Lack of pneumatization, fat pockets, mixed dentition, contribute to the elasticity and bone stability. When mandibular fractures occur in children, most often involve the condyle by indirect trauma. Such fractures are the center of discussion on the form of treatment if this should be performed conservatively, or held the reduction and fixation of the fracture with surgical exposure of the fragments. In condylar fractures in children, in most patients, the proposed treatment is closed reduction. Treatment with open reduction and fixation has its specific indications. In this case, the authors report a patient cycling accident victim, with cut-contusion injury in ment with limited mouth opening and left condylar fracture with medial rotation. The treatment was the reduction and fixation of fragments by open process.

  7. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Haematoma block in reduction of distal radial fractures.

    PubMed

    Ogunlade, S O; Omololu, A B; Alonge, T O; Salawu, S A; Bamgboye, E A

    2002-01-01

    A total of 35 patients who presented in the Accident and Emergency Department of University College Hospital with displaced distal radial fracture between January 2000 and March 2001 had reduction of the fracture under haematoma block using 10ml of 2% lignocaine. There was significant reduction of the pain following infiltration of the fracture site with lignocaine and significant pain reduction during manipulation compared to pain score at presentation. All the patients had satisfactory reduction of the fracture. The fracture was mobilised in Plaster of Paris 6 weeks in patients with Collens' fracture and 3 weeks in patients with distal radial epiphyseal injury. All patients had good range of movement at 8 weeks after removal of Plaster of Paris and patients expressed satisfaction with this method. We recommend the use of Haematoma block for patients of 15 years and above with displaced distal radial fracture in the Accident and Emergency Department.

  9. Evaluation of Bite Force After Open Reduction and Internal Fixation Using Microplates

    PubMed Central

    Kumar, S Tharani; Saraf, Saurabh; Devi, S Prasanna

    2013-01-01

    The primary aim of this study is to determine maximum bite force in molar and incisor regions of healthy individuals, to evaluate the bite force after open reduction and internal fixation of mandibular fractures using micro plates, for a period of up to 6 weeks and to determine the rate of recovery of maximum bite force in an Indian population. PMID:24910656

  10. Sanders II type calcaneal fractures: a retrospective trial of percutaneous versus operative treatment.

    PubMed

    Wang, Ye-ming; Wei, Wan-fu

    2015-02-01

    The purpose of this study was to compare the clinical results of percutaneous reduction and Steinman pin fixation for Sanders II calcaneal fractures with those of operative management through an extensile lateral approach. Fifty-three patients treated with standard open reduction and internal fixation (ORIF group) and 54 patients who had undergone percutaneous reduction and Steinman pin fixation (CRIF group) were retrospectively reviewed. There were no differences between the groups regarding sex, age or fracture classification. Pain and functional outcome were evaluated with a visual analogue scale (VAS) and American Orthopaedic Foot and Ankle Society (AOFAS) scores. Wound complications and radiological results were compared. At a mean follow-up of 40.4 months (24 to 56 months), there were no differences between the two groups in mean AOFAS score, VAS score or radiologically determined variables. Two cases of deep infection and six of poor wound healing occurred in the ORIF group and none in the CRIF group. Subtalar and ankle motion was found to be better in the CRIF group. Percutaneous reduction and Steinman pin fixation minimizes complications and achieves functional outcomes comparable to those of the open techniques in patients with Sanders II calcaneal fractures. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  11. Surgical treatment of comminuted mandibular fractures using a low-profile locking mandibular reconstruction plate system

    PubMed Central

    Kanno, Takahiro; Sukegawa, Shintaro; Nariai, Yoshiki; Tatsumi, Hiroto; Ishibashi, Hiroaki; Furuki, Yoshihiko; Sekine, Joji

    2014-01-01

    Objective: The treatment of comminuted mandibular fractures is challenging due to the severity of associated injuries and the need for a careful diagnosis with adequate treatment planning. Recently, open reduction and stable internal fixation (OR-IF) with a load-bearing reconstruction plate have been advocated for reliable clinical outcomes with minimal complications. This clinical prospective study evaluated OR-IF in the surgical management of comminuted mandibular fractures with a new low-profile, thin, mandibular locking reconstruction plate. Materials and Methods: We prospectively assessed OR-IF of comminuted mandibular fractures with a low-profile locking mandibular reconstruction plate in 12 patients (nine men, three women; mean age 32.2 [range 16-71] years) between April 2010 and December 2011. The clinical characteristics and associated clinical parameters of patients were evaluated over a minimum follow-up period of 12 months. Results: Traffic accidents caused 50% of the fractures, followed by falls (25%). Four patients (33.3%) had associated midfacial maxillofacial fractures, while five patients had other mandibular fractures. Seven patients (58.3%) needed emergency surgery, mostly for airway management. Anatomical reduction of the comminuted segments re-established the mandibular skeleton in stable occlusion with rigid IF via extraoral (33.3%), intraoral (50%), or combined (16.7%) approaches. Immediate functional recovery was achieved. Sound bone healing was confirmed in all patients, with no complications such as malocclusion, surgical site infection, or malunion with a mean follow-up of 16.3 (range 12-24) months. Conclusions: OR-IF using a low-profile reconstruction plate system is a reliable treatment for comminuted mandibular fractures, enabling immediate functional recovery with good clinical results. PMID:25593862

  12. Retrospective analysis of two hundred thirty-five pediatric mandibular fracture cases.

    PubMed

    Eskitascioglu, Teoman; Ozyazgan, Irfan; Coruh, Atilla; Gunay, Galip K; Yuksel, Esabil

    2009-11-01

    Maxillofacial fractures are encountered less commonly during childhood period due to anatomic, social, cultural, and environmental factors. Although the incidence of all maxillofacial fractures is 1% to 15% among pediatric and adolescent patients, this rate drops to less than 1% in children below 5 years age. Two hundred thirty-five cases (

  13. Omnidirectional Internal Fixation by Double Approaches for Treating Rüedi-Allgöwer Type III Pilon Fractures.

    PubMed

    Dai, Chong-Hua; Sun, Jun; Chen, Kun-Quan; Zhang, Hui-Bo

    In the present study, we explored the effectiveness and complications of omnidirectional internal fixation using a double approach for treating Rüedi-Allgöwer type III pilon fractures. A retrospective analysis was performed of 19 cases of Rüedi-Allgöwer type III unilateral closed pilon fracture. With preoperative preparation and correct surgical timing, the reduction was performed using anteromedial and posterolateral approaches, and the fracture fragments were fixed by omnidirectional internal fixation. Imaging evaluation was performed using the Burwell-Charnley scoring system. The Johner-Wruhs scoring system was used to assess the functional status of the patients. A comprehensive evaluation of efficacy was performed using a 5-point Likert score. The complications were also recorded and analyzed. All patients were followed up for an average of 16.2 months. The operative incisions of 15 cases healed by primary intent and with delayed healing in 4. All patients had achieved bony union at an average of 16 weeks postoperatively. No deep infection, broken nail or withdrawn nail, exposed plate, or skin flap necrosis occurred. The Burwell-Charnley imaging evaluation showed that 14 patients had anatomic reduction of the articular surface and 5 had acceptable reduction. Using the Johner-Wruhs scoring system, the results were excellent for 8, good for 7, fair for 2, and poor for 2 patients; the combined rate of excellent and good results was 78.9%. The Likert score of efficacy self-reported by the patients was 3 to 4 points for 12 patients, 2 points for 4 patients, and 0 to 1 point for 3 patients. The Likert score of therapeutic efficacy reported by the physicians was 3 to 4 points for 10 patients, 2 points for 5 patients, and 0 to 1 point for 4 patients. Omnidirectional internal fixation using double approaches was an effective method to treat Rüedi-Allgöwer type III pilon fractures with satisfactory reduction and rigid fixation, good joint function recovery, and few complications. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Improvement in spine bone density and reduction in risk of vertebral fractures during treatment with antiresorptive drugs.

    PubMed

    Cummings, Steven R; Karpf, David B; Harris, Fran; Genant, Harry K; Ensrud, Kristine; LaCroix, Andrea Z; Black, Dennis M

    2002-03-01

    To estimate how much the improvement in bone mass accounts for the reduction in risk of vertebral fracture that has been observed in randomized trials of antiresorptive treatments for osteoporosis. After a systematic search, we conducted a meta-analysis of 12 trials to describe the relation between improvement in spine bone mineral density and reduction in risk of vertebral fracture in postmenopausal women. We also used logistic models to estimate the proportion of the reduction in risk of vertebral fracture observed with alendronate in the Fracture Intervention Trial that was due to improvement in bone mineral density. Across the 12 trials, a 1% improvement in spine bone mineral density was associated with a 0.03 decrease (95% confidence interval [CI]: 0.02 to 0.05) in the relative risk (RR) of vertebral fracture. The reductions in risk were greater than predicted from improvement in bone mineral density; for example, the model estimated that treatments predicted to reduce fracture risk by 20% (RR = 0.80), based on improvement in bone mineral density, actually reduce the risk of fracture by about 45% (RR = 0.55). In the Fracture Intervention Trial, improvement in spine bone mineral density explained 16% (95% CI: 11% to 27%) of the reduction in the risk of vertebral fracture with alendronate. Improvement in spine bone mineral density during treatment with antiresorptive drugs accounts for a predictable but small part of the observed reduction in the risk of vertebral fracture.

  15. Surgical treatment of intra-articular calcaneal fractures.

    PubMed

    Stapleton, John J; Zgonis, Thomas

    2014-10-01

    Most intra-articular calcaneal fractures are a result of high-energy trauma. The operative management of calcaneal fractures has been based on achieving anatomic reduction and minimizing complications of the compromised soft tissue envelope. The traditional extensile lateral approach offers advantages of achieving adequate fracture reduction with the risk of wound-healing complications and infection. Limited open reduction and internal fixation techniques with or without using external fixation focuses on achieving fracture reduction with less risk of wound complications but higher risk of malunion. This article discusses key points of operative management for various intra-articular calcaneal fracture patterns and clinical presentations. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. The anterolateral acromial approach for fractures of the proximal humerus.

    PubMed

    Gardner, Michael J; Boraiah, Sreevathsa; Helfet, David L; Lorich, Dean G

    2008-02-01

    Displaced and unstable fractures of the proximal humerus are notoriously difficult to manage. Successful surgical treatment requires finding the appropriate balance between adequate exposure for reduction and rigid fixation and minimizing soft tissue dissection. The anterolateral acromial approach was developed to allow less invasive treatment of proximal humerus fractures. The plane of the avascular anterior deltoid raphe is utilized, and the axillary nerve is identified and protected. Anterior dissection near the critical blood supply is avoided, substantial muscle retraction is minimized, and the lateral plating zone is directly accessed. Over a 4-year period, 52 patients with acute displaced fractures of the proximal humerus were treated with the anterolateral acromial approach and either a locking plate or an intramedullary nail. Twenty-three patients were evaluated clinically at a minimum follow-up of 1 year (average, 28 months) by clinical examination for range of motion and nerve function and a QuickDASH score. There were no axillary nerve deficits postoperatively related to the approach, and the average QuickDASH score was 25.2 (0, best; 100, worst). This approach allowed direct access to the lateral fracture planes for fracture reduction and plate placement or safe nail and interlocking screw placement.

  17. Calcaneal apophyseal avulsion fracture.

    PubMed

    Imai, Yuuki; Kitano, Toshio; Nakagawa, Keisuke; Takaoka, Kunio

    2007-07-01

    Isolated fracture of the calcaneal apophysis is a rare injury in children and adolescents. In this study, we report on a case of a displaced calcaneal apophyseal avulsion fracture in a child treated with open reduction and internal fixation, as well as a review of the literature. A 9-year-old female child presented to the senior surgeon complaining of acute heel pain after a gymnastic injury. She was diagnosed with a displaced, isolated fracture of the proximal calcaneal apophysis for which she underwent open reduction and internal fixation. On the magnetic resonance imaging (MRI) examination, we could diagnose that her injury was not chronic but acute because there was no change of intensity in the metaphyseal area. A combination of bioabsorbable suture tacks and pins was used to anatomically fix the fragment using the tension band wiring technique. At 2 years and 6 months follow-up, she had full range of motion, complete return of strength. We report here on the successful surgical treatment and the first case evaluated by MRI of an avulsion fracture of the calcaneal apophysis in a child.

  18. The Measurement of the Sensory Recovery Period in Zygoma and Blow-Out Fractures with Neurometer Current Perception Threshold.

    PubMed

    Oh, Daemyung; Yun, Taebin; Kim, Junhyung; Choi, Jaehoon; Jeong, Woonhyeok; Chu, Hojun; Lee, Soyoung

    2016-09-01

    Facial hypoesthesia is one of the most troublesome complaints in the management of facial bone fractures. However, there is a lack of literature on facial sensory recovery after facial trauma. The purpose of this study was to evaluate the facial sensory recovery period for facial bone fractures using Neurometer. Sixty-three patients who underwent open reduction of zygomatic and blowout fractures between December 2013 and July 2015 were included in the study. The facial sensory status of the patients was repeatedly examined preoperatively and postoperatively by Neurometer current perception threshold (CPT) until the results were normalized. Among the 63 subjects, 30 patients had normal Neurometer results preoperatively and postoperatively. According to fracture types, 17 patients with blowout fracture had a median recovery period of 0.25 months. Twelve patients with zygomatic fracture had a median recovery period of 1.00 month. Four patients with both fracture types had a median recovery period of 0.625 months. The median recovery period of all 33 patients was 0.25 months. There was no statistically significant difference in the sensory recovery period between types and subgroups of zygomatic and blowout fractures. In addition, there was no statistically significant difference in the sensory recovery period according to Neurometer results and the patients' own subjective reports. Neurometer CPT is effective for evaluating and comparing preoperative and postoperative facial sensory status and evaluating the sensory recovery period in facial bone fracture patients.

  19. [Medial versus lateral plating in distal tibial fractures: a prospective study of 40 fractures].

    PubMed

    Encinas-Ullán, C A; Fernandez-Fernandez, R; Rubio-Suárez, J C; Gil-Garay, E

    2013-01-01

    Tibial plafond fractures are one of the most challenging injuries in orthopaedic surgery. Their results could be improved by following the new guidelines for the management, and modern plating techniques. The results and complication rate between anteromedial and anterolateral approach for open reduction and internal fixation of these fractures were compared. A study was conducted on 40 patients treated by open reduction an internal fixation between 2007 and 2008. The surgical approach was selected by the surgeon in charge, depending on fracture pattern and skin situation. Patients were evaluated clinically and radiographically by an independent orthopaedic surgeon, not involved in the surgical procedure, using clinical (American Orthopaedic Foot and Ankle Society score) and radiological criteria at a minimum of two years. The appearance of complications after both approaches was recorded. Forty patients were included. The mean age was 53 years, with 24 males and 16 females. Seventeen of the injuries were of high energy, and there were 8 open fractures (3 of type i, 4 type ii and one type iii), and 12 of the closed injuries were grade ii or iii in the Tscherne classification. Six patients (15%) had associated injuries. At final follow-up there were 33 (82%) excellent or good results. No statistical differences were found between either surgical approach regarding time to bone union, rate of delayed union and infection rate. Three plates of the anteromedial group and none of the anterolateral group needed to be removed. Open reduction and internal fixation of distal tibia fractures produced reliable results, with no statistical differences found between anteromedial and anterolateral surgical approaches. Clinical and radiological results and complication rate were mainly related to the fracture type. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Surgical treatment of open pilon fractures.

    PubMed

    Zeng, Xian-tie; Pang, Gui-gen; Ma, Bao-tong; Mei, Xiao-long; Sun, Xiang; Wang, Jia; Jia, Peng

    2011-02-01

    To discuss the methods, timing and clinical outcomes of surgical treatment for open pilon fractures. From April 2003 to July 2008, 28 patients with open pilon fractures were treated. All had type C fractures according to the Arbeitsgemeinschaft für osteosynthesefragen-Association for the Study of Internal Fixation (AO/ASIF) classification. Three operative methods were applied, the methods being determined by the types of fracture, soft tissue damage and time interval after injury. Seven cases were treated by debridement and internal fixation with plate; 19 by limited internal fixation combined with external fixation; and 2 by delayed surgery. The clinical outcomes were evaluated by the Burwell-Charnley score. All cases were followed up for from 6 to 48 months (average 24 months). The Burwell-Charnley score of clinical outcomes: anatomic reduction achieved in 12 cases, functional reduction in 15, and unsatisfactory reduction in 1. The healing time was from 2.5 to 11 months (average 4.7 months). Two cases had delayed union. According to the American Orthopaedic Foot and Ankle Society (AOFAS) scale for the ankle joint, there were excellent results in 8 cases, good in 14, fair in 5 and poor in 1. Complications included four cases of skin superficial sloughing, two of superficial infection, one of deep infection, two of delayed fracture union and ten of post-traumatic arthritis. It is important to perform appropriate surgeries for open pilon fracture according to fracture classification, different damage to skin and tissue and time interval after injury. Thorough debridement, proper use of anti-infective medication, appropriate bone grafting, and postoperative ankle function exercise can reduce the occurrence of complications. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  1. Comparative Evaluation of Enalapril and Losartan in Pharmacological Correction of Experimental Osteoporosis and Fractures of Its Background

    PubMed Central

    Rajkumar, D. S. R.; Faitelson, A. V.; Gudyrev, O. S.; Dubrovin, G. M.; Pokrovski, M. V.; Ivanov, A. V.

    2013-01-01

    In the experiment on the white Wistar female rats (222 animals), the osteoprotective effect of enalapril and losartan was studied on experimental models of osteoporosis and osteoporotic fractures. It was revealed that in rats after ovariectomy, the endothelial dysfunction of microcirculation vessels of osteal tissue develops, resulting in occurrence of osteoporosis and delay of consolidation of experimental fractures. Enalapril and losartan prevented the reduction of microcirculation in bone, which was reflected in slowing the thinning of bone trabeculae and in preventing the occurrence of these microfractures, as well as increasing quality of experimental fractures healing. PMID:23401845

  2. Radiographic Evaluation of Ankle Joint Stability After Calcaneofibular Ligament Elevation During Open Reduction and Internal Fixation of Calcaneus Fracture.

    PubMed

    Wang, Chien-Shun; Tzeng, Yun-Hsuan; Lin, Chun-Cheng; Huang, Ching-Kuei; Chang, Ming-Chau; Chiang, Chao-Ching

    2016-09-01

    The aim of this prospective study was to evaluate the influence of sectioning the calcaneofibular ligament (CFL) during an extensile lateral approach during open reduction and internal fixation (ORIF) of calcaneal fractures on ankle joint stability. Forty-two patients with calcaneal fractures that received ORIF were included. Talar tilt stress and anterior drawer radiographs were performed on the operative and contralateral ankles 6 months postoperatively. The average degree of talar tilt on stress radiographs was 3.4 degrees (range, 0-12 degrees) on the operative side and 3.2 degrees (range, 0-14 degrees) on the contralateral side. The mean anterior drawer on stress radiographs of the CFL incised ankle was 6.1 mm (range, 2.4-11.8 mm) and on the contralateral ankle was 5.7 mm (range, 2.6-8.6 mm). There was no statistically significant difference of talar tilt and anterior drawer between the CFL incised side and the contralateral side (P = .658 and .302, respectively). The results suggest that sectioning of the CFL without any repair during ORIF of a calcaneal fracture does not have a negative effect on stability of the ankle. Repair of the CFL is, thus, probably not necessary following extended lateral approach for ORIF of calcaneal fractures. Level II, comparative study. © The Author(s) 2016.

  3. Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja

    2016-10-01

    In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.

  4. Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures.

    PubMed

    Taylor, Benjamin C; Hansen, Dane C; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel

    2016-01-01

    Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted.

  5. Talocrural Dislocation With Associated Weber Type C Fibular Fracture in a Collegiate Football Player: A Case Report

    PubMed Central

    Ricci, R Daniel; Cerullo, James; Blanc, Robert O; McMahon, Patrick J; Buoncritiani, Anthony M; Stone, David A; Fu, Freddie H

    2008-01-01

    Objective: To present the case of a talocrural dislocation with a Weber type C fibular fracture in a National Collegiate Athletic Association Division I football athlete. Background: The athlete, while attempting to make a tackle during a game, collided with an opponent, who in turn stepped on the lateral aspect of the athlete's ankle, resulting in forced ankle eversion and external rotation. On-field evaluation showed a laterally displaced talocrural dislocation. Immediate reduction was performed in the athletic training room to maintain skin integrity. Post-reduction radiographs revealed a Weber type C fibular fracture and increased medial joint clear space. A below-knee, fiberglass splint was applied to stabilize the ankle joint complex. Differential Diagnosis: Subtalar dislocation, Maisonneuve fracture, malleolar fracture, deltoid ligament rupture, syndesmosis disruption. Treatment: The sports medicine staff immediately splinted and transported the athlete to the athletic training room to reduce the dislocation. The athlete then underwent an open reduction and internal fixation procedure to stabilize the injury: 2 syndesmosis screws and a fibular plate were placed to keep the ankle joint in an anatomically reduced position. With the guidance of the athletic training staff, the athlete underwent an accelerated physical rehabilitation protocol in an effort to return to sport as quickly and safely as possible. Uniqueness: Most talocrural dislocations and associated Weber type C fibular fractures are due to motor vehicle accidents or falls. We are the first to describe this injury in a Division I football player and to present a general rehabilitation protocol for a high-level athlete. Conclusions: Sports medicine practitioners must recognize that this injury can occur in the athletic environment. Prompt reduction, early surgical intervention, sufficient resources, and an accelerated rehabilitation protocol all contributed to a successful outcome in the patient. PMID:18523569

  6. Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography.

    PubMed

    Endo, Jun; Yamaguchi, Satoshi; Saito, Masahiko; Morikawa, Tsuguo; Akagi, Ryuichiro; Sasho, Takahisa

    2016-10-01

    To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. The mean anterior tibiofibular distance was 0.7mm after syndesmotic fixation. It increased to 1.9mm at one year after screw removal (p=0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1mm vs. 0.6mm for the posterior tibiofibular distance, 0.2mm vs. 0.3mm for the anteroposterior fibular translation, and 0.7° vs. 0° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation (p=0.01) and from 20% to 60% at one year after screw removal (p=0.02). The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. Copyright © 2016. Published by Elsevier Ltd.

  7. Study of the X-Ray Diagnosis of Unstable Pelvic Fracture Displacements in Three-Dimensional Space and its Application in Closed Reduction.

    PubMed

    Shi, Chengdi; Cai, Leyi; Hu, Wei; Sun, Junying

    2017-09-19

    ABSTRACTS Objective: To study the method of X-ray diagnosis of unstable pelvic fractures displaced in three-dimensional (3D) space and its clinical application in closed reduction. Five models of hemipelvic displacement were made in an adult pelvic specimen. Anteroposterior radiographs of the pelvis were analyzed in PACS. The method of X-ray diagnosis was applied in closed reductions. From February 2012 to June 2016, 23 patients (15 men, 8 women; mean age, 43.4 years) with unstable pelvic fractures were included. All patients were treated by closed reduction and percutaneous cannulate screw fixation of the pelvic ring. According to Tile's classification, the patients were classified into type B1 in 7 cases, B2 in 3, B3 in 3, C1 in 5, C2 in 3, and C3 in 2. The operation time and intraoperative blood loss were recorded. Postoperative images were evaluated by Matta radiographic standards. Five models of displacement were made successfully. The X-ray features of the models were analyzed. For clinical patients, the average operation time was 44.8 min (range, 20-90 min) and the average intraoperative blood loss was 35.7 (range, 20-100) mL. According to the Matta standards, 7 cases were excellent, 12 cases were good, and 4 were fair. The displacements in 3D space of unstable pelvic fractures can be diagnosed rapidly by X-ray analysis to guide closed reduction, with a satisfactory clinical outcome.

  8. Comparison of arthroscopic reduction and percutaneous fixation and open reduction and internal fixation for tibial plateau fractures.

    PubMed

    Sun, Yufu; Sun, Kai; Jiang, Wenxue

    2018-06-01

    To conduct a meta-analysis with randomized controlled trials (RCTs) published in full text to demonstrate database to show the associations of perioperative, postoperative outcomes of arthroscopic reduction and percutaneous fixation(ARPF) and open reduction and internal fixation(ORIF) for tibial plateau fractures to provide the predictive diagnosis for clinic. Literature search was performed in PubMed, Embase, Web of Science and Cochrane Library for information from the earliest date of data collection to June 2017. RCTs comparing the benefits and risks of ARPF with those of ORIF in tibial plateau fractures were included. Statistical heterogeneity was quantitatively evaluated by X 2 test with the significance set P < 0.10 or I 2  > 50%. Seven RCTs consisting of 571 patients were included.(288 ARPF patients; 283 ORIF patients;). Pooled results showed that ORIF was related to a greater increase in operative time, incision length, hospital stay, perioperative complications, and full weight bearing compared with ARPF. The results showed that ARPF was related to a greater increase in ROM Rasmussen Scores compared with ORIF (WMD = 10.38; 95% CI, 8.31, 12.45; P < 0.10). This meta-analysis showed that arthroscopic reduction and percutaneous fixation for tibial plateau fractures, compared with open reduction and internal fixation, could demonstrate an decreased risk of perioperative and postoperative complications and improve clinical outcome in operative time, incision length, hospital stay, perioperative complications, full weight bearing and Rasmussen Scores. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    PubMed

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  10. [Balloon osteoplasty as reduction technique in the treatment of tibial head fractures].

    PubMed

    Freude, T; Kraus, T M; Sandmann, G H

    2015-10-01

    Tibial plateau fractures requiring surgery are severe injuries of the lower extremities. Depending on the fracture pattern, the age of the patient, the range of activity and the bone quality there is a broad variation in adequate treatment.  This article reports on an innovative treatment concept to address split depression fractures (Schatzker type II) and depression fractures (Schatzker type III) of the tibial head using the balloon osteoplasty technique for fracture reduction. Using the balloon technique achieves a precise and safe fracture reduction. This internal osteoplasty combines a minimal invasive percutaneous approach with a gently rise of the depressed area and the associated protection of the stratum regenerativum below the articular cartilage surface. This article lights up the surgical procedure using the balloon technique in tibia depression fractures. Using the balloon technique a precise and safe fracture reduction can be achieved. This internal osteoplasty combines a minimally invasive percutaneous approach with a gentle raising of the depressed area and the associated protection of the regenerative layer below the articular cartilage surface. Fracture reduction by use of a tamper results in high peak forces over small areas, whereas by using the balloon the forces are distributed over a larger area causing less secondary stress to the cartilage tissue. This less invasive approach might help to achieve a better long-term outcome with decreased secondary osteoarthritis due to the precise and chondroprotective reduction technique.

  11. Bilateral femoral neck stress fractures in a fire academy student.

    PubMed

    Wright, Russell C; Salzman, Garrett A; Yacoubian, Stephan V; Yacoubian, Shahan V

    2010-10-11

    Unilateral femoral neck stress fractures are well documented in active patients; however, the risk of a subsequent contralateral stress fracture remains unknown in patients who continue to be active. This article describes a 24-year-old male fire academy student who sustained a left femoral neck stress fracture, followed approximately 11 months later by a right femoral neck stress fracture, both of which went on to completely displace. A review of the index radiographs of each hip from outside institutions revealed femoral neck stress fractures that went undiagnosed until they displaced. The patient was referred to our institution and underwent closed reduction and internal fixation using cannulated screws in both cases. A full endocrine evaluation was performed in the following weeks and proved unremarkable. Although it is difficult to extrapolate the results from 1 patient beyond the case studied, there is cause for concern in patients who remain active following femoral neck stress fractures. Our case highlights the significance of obtaining a complete and thorough medical history on physical examination and appropriately counseling patients regarding activity level. Until further research explores this possible relationship, physicians evaluating patients with a history of a stress fracture are encouraged to be vigilant of subsequent contralateral fractures and educate patients of this potentially avoidable injury. Copyright 2010, SLACK Incorporated.

  12. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    PubMed

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  13. Risk of Osteosarcoma in Dogs After Open Fracture Fixation.

    PubMed

    Arthur, Elizabeth G; Arthur, Gerald L; Keeler, Matthew R; Bryan, Jeffrey N

    2016-01-01

    To critically evaluate whether open fracture fixation is a significant risk factor for latent osteosarcoma development. Case-control study. Dogs undergoing open fracture repair and dogs diagnosed with osteosarcoma. Records were retrieved from the Veterinary Medical Database VMDB (1970-2000) for dogs undergoing surgical repair of a fracture and dogs diagnosed with osteosarcoma. Dogs with open reduction of joint luxation, dogs diagnosed with bacterial cystitis, and dogs diagnosed with urinary bladder transitional cell carcinoma (UBTCC) were queried as comparison populations. Relative risk for osteosarcoma development was determined. From a population of 19,041 fractures treated surgically, 15 of those dogs subsequently appeared in the VMDB with osteosarcoma affecting the same bone. The relative risk of a fracture repair and associated orthopedic implants and osteosarcoma occurrence was equivalent to the relative risk of open joint reduction and osteosarcoma occurrence (95% confidence interval; 0.998-1.00). The relative risk of having bacterial cystitis and appearing again in the VMDB with UBTCC was higher than the risk of open fracture repair and a subsequent diagnosis of osteosarcoma (P < .02). The incidence of fracture-related osteosarcoma may be significantly less than previously estimated based on cases queried from the VMDB. Although possible cases of implant-associated osteosarcoma were identified, their occurrence was rare. Elective implant removal for the purpose of reducing the risk of osteosarcoma after fracture repair may not be warranted and merits further investigation. © Copyright 2015 by The American College of Veterinary Surgeons.

  14. [Early operative treatment of pelvic fractures associated with urethral disruption].

    PubMed

    Jia, Jian; Guo, Lu-Zeng; Wu, Chang-Lin; Chen, Jia-Geng; Zhang, Tie-Liang; Pei, Fu-Xing

    2007-02-15

    To evaluate the early operative treatment and clinical results of pelvic fractures associated with urethra disruption. From January 1995 to January 2005, 25 patients suffered from pelvic fractures combined urethra disruption treated by operation were retrospectively analyzed. According to Tile's classification, 1 case was stable pelvic fracture, 17 rotational unstable fractures, and 7 rotational combined vertical unstable fractures. The complete urethra rupture were in 23 cases and incomplete in 2 cases. The operative methods included: (1) emergency open reduction and internal fixation of the pelvis combined primary urethra suturing in 2 cases, partial suturing after realignment in 4 cases, realignment in 2 cases, and urethrovaginal penetrating wound repairing in 1 case; (2) primary urethra realignment only and delayed (range, 7 to 21 days) pelvic internal fixation in 10 cases; (3) early cystostomy and delayed (range, 3 to 21 days) urethra realignment and pelvic internal fixation in 6 cases. The mean follow-up time of all patients was 34 months (range from 6 to 120 months). According to Majeed's evaluation, 17 cases of pelvic injury showed excellent results, 5 good, and 3 fare. After urinary catheter removed, the mean maximal urine flow rate of 19 (76%) patients was 18.6 ml/s and the mean scar length between both disrupted ends on the film of excretion urethrography was 0.51 cm. Five (20%) cases suffered in dysuria needed urethral dilatation or further surgery. One (4%) female could not control urination who need a second-look operation. The primary suprapubic soft tissue avulsion wound infection secondary to retropubic abscess was found in 1 case, posterior urethra-stenosis in 5 cases, sexual impotence in 3 cases, and incontinence in 1 case. The satisfactory reduction and effective fixation of the pelvic fractures is an anatomical basis for receiving "tension-free urethral anastomosis".

  15. Bilateral mandibular angle fractures: clinical considerations.

    PubMed

    Boffano, Paolo; Roccia, Fabio

    2010-03-01

    The mandibular angle is a frequent site of fracture. It is a weak zone that is more exposed to fractures than other areas of the mandibular bone. The presence of incompletely erupted third molars is associated with a further increased risk of angle fractures. Our objective was to evaluate and discuss the surgical outcomes of a group of patients with bilateral mandibular angle fractures.In our study, patients with bilateral mandibular angle fractures surgically treated from January 1, 2001, to June 30, 2009, at the Division of Maxillofacial Surgery of the University of Turin were retrospectively analyzed. A combined transbuccal and intraoral approach or an intraoral approach only was adopted.Eight patients (7 men and 1 woman) underwent surgery for bilateral mandibular angle fractures. Good to satisfactory reduction of the fractures was obtained with both surgical techniques. Good to fair restored occlusion was observed postoperatively in all patients.Successful treatment of bilateral mandibular angle fractures may be achieved via different techniques. Superficially impacted third molars seem to be associated with an increased risk of angle fractures. Bilateral angle fractures are an ideal model to study the biomechanical pathogenesis of angle fractures.

  16. Mandibular Fractures in Iraq: An Epidemiological Study

    PubMed Central

    Bede, Salwan

    2014-01-01

    The purpose of this study was to evaluate the epidemiological characteristics of the mandibular fractures relating to gender, age, the etiology of injury, and the rendered treatment modalities and complications. The data of the patients who sustained mandibular fractures were retrieved and were analyzed retrospectively, and based on these data a descriptive analysis was conducted. A total of 112 patients were included in this study; the most common cause was road traffic accidents (RTAs) followed by assaults and missile injuries. The most frequently involved age group was 11 to 20 years, treatment modalities included conservative, closed reduction and indirect fixation, and open reduction and internal fixation (ORIF) in 11.6, 79.5, and 8.9% of the cases, respectively. Most of the major complications were injury related. This study showed RTAs to be the most frequent cause followed by assaults, it also showed that a high percentage of assault victims were females mainly of low socioeconomic status. Another distinguishing feature in this study was the high incidence of missile injuries in the form of bullets and blasts. Closed reduction still has an important role in the treatment of fractures of mandible especially when the necessary equipments for ORIF are not readily available. A higher complication rate was observed in patients diagnosed with multiple and comminuted fractures as well as those caused by violence in the form of missile and assault injuries. PMID:25709754

  17. Flowpath independent monitoring of reductive dechlorination potential in a fractured rock aquifer

    USGS Publications Warehouse

    Bradley, P.M.; Lacombe, P.J.; Imbrigiotta, T.E.; Chapelle, F.H.; Goode, D.J.

    2009-01-01

    The flowpath dependent approaches that are typically employed to assess biodegradation of chloroethene contaminants in unconsolidated aquifers are problematic in fractured rock settings, due to difficulties defining discrete groundwater flowpaths in such systems. In this study, the variation in the potential for chloroethene biodegradation with depth was evaluated in a fractured rock aquifer using two flowpath independent lines of field evidence: (1) the presence of the three biochemical prerequisites [electron donor(s), chloroethene electron acceptor(s), and chlororespiring microorganism(s)] for efficient chloroethene chlororespiration and (2) the in situ accumulation of chloroethene reductive dechlorination daughter products. The validity of this approach was assessed by comparing field results with the results of [1, 2- 14C] cis-DCE microcosm experiments. Microcosms were prepared with depth-specific core material, which was crushed and emplaced in discrete packer intervals for 1 year to allow colonization by the indigenous microbial community. Packer intervals characterized by significant electron donor concentrations, elevated numbers of chlororespiring microorganisms, and high reductive dechlorination product to parent contaminant ratios correlated well with the production of 14C-labeled reductive dechlorination products in the microcosm experiments. These results indicate that, in the absence of information on discrete groundwater flowpaths, a modified approach emphasizing flowpath independent lines of evidence can provide insight into the temporal and spatial variability of contaminant biodegradation in fractured rock systems. ?? 2009 National Ground Water Association.

  18. Mandible Fracture Complications and Infection: The Influence of Demographics and Modifiable Factors.

    PubMed

    Odom, Elizabeth B; Snyder-Warwick, Alison K

    2016-08-01

    Mandible fractures account for 36 to 70 percent of all facial fractures. Despite their high prevalence, the literature lacks a comprehensive review of demographics, fracture patterns, timing of management, antibiotic selection, and outcomes, particularly when evaluating pediatric versus adult patients. The authors aim to determine the complication and infection rates after surgical treatment of mandibular fractures and the bacterial isolates and antibiotic sensitivities from mandible infections after open reduction and internal fixation at their institution. Data were collected retrospectively for all mandible fractures treated at the authors' institution between 2003 and 2013. Patients were divided into pediatric (younger than 16 years) and adult (16 years or older) subgroups. Demographics, fracture location, fracture cause, comorbidities, antibiotic choice, and subsequent complications and infections were analyzed. Data were evaluated using appropriate statistical tests for each variable. Three hundred ninety-five patients were evaluated. Demographics and fracture cause were similar to those reported in current literature. Of the 56 pediatric patients, complications occurred in 5.6 percent. Time from injury to operative intervention did not affect outcome. The complication rate was 17.5 percent and the infection rate was 9.4 percent in the adult subgroup. Time from injury to operative intervention, sex, and edentulism were not significant predictors of complication or infection. Tobacco use, number of fractures, number of fractures fixated, and surgical approach were predictors of complication and infection. Perioperative ampicillin-sulbactam had a significantly lower risk of infection. Certain demographic and operative factors lead to significantly higher risks of complications after surgical management of mandibular fractures. Ampicillin-sulbactam provides effective antibiotic prophylaxis. Risk factor modification may improve outcomes. Risk, IV.

  19. Callus features of regenerate fracture cases in femoral lengthening in achondroplasia.

    PubMed

    Devmurari, Kamlesh N; Song, Hae Ryong; Modi, Hitesh N; Venkatesh, K P; Ju, Kim Seung; Song, Sang Heon

    2010-09-01

    We studied the callus features seen in cases of regenerate fracture in femoral lengthening using a monolateral fixator in achondroplasia to determine whether callus types and shapes can predict the probability of callus fracture. The radiographs of 28 cases of femoral lengthening in 14 patients, 14 cases of callus fracture, and 14 cases without callus fracture were retrospectively analyzed by four observers and classified into different shapes and types in concordance with the Ru Li classification. The average lengthening of 9.4 cm (range 7.5-11.8 cm) was achieved, which was 41% (range 30-55%) of the original length and the average timing of callus fracture was 470 days (range 440-545 days) after surgery in the callus fracture group. While the average lengthening of 9.1 cm (range 8-9.7 cm) was achieved, this was 30% (range 28-32%) of the original length in the group of patients without callus fracture. The callus was atypically shaped, there was a 48% average (range 30-72%) reduction of the callus width compared with the natural width of the femur, and a lucent pathway was present in all cases of regenerate fracture. A lucent pathway was seen in all fracture cases with concave, lateral, and atypical shapes, and there was more than 30% lengthening and 30% reduction of the callus width compared with the natural width of the femur, which are the warning signs for regenerate fractures. These signs help the surgeon to predict the outcome and guide him in planning for any additional interventions. The Ru Li classification is an effective method for the evaluation of the chance of callus fracture.

  20. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.

    PubMed

    Hsu, Kai-Lan; Chang, Wei-Lun; Yang, Chyun-Yu; Yeh, Ming-Long; Chang, Chih-Wei

    2017-12-01

    Modified tension band wiring has been widely used to treat transverse patellar fractures. However, few studies have evaluated the clinical outcomes using different methods of Kirschner wire bending, location of the tension band, and depths of Kirschner wires. Thus, we tried to clarify these factors according to our clinical outcomes. This retrospective cohort study recruited consecutive patients underwent surgical fixation for patellar fractures using modified tension band technique between January 2010 and December 2015. Different factors in this procedure, including the bending manner of the Kirschner wires, their depth, and location of the tension band with respect to the superior and inferior border of the patella were recorded and analysed. The primary outcome was early loss of fixation. The secondary outcomes were minor loss of reduction, implant breakage, deep infection, and the need for implant removal. This study included 170 patients with patellar fractures. Regarding the bending method, similar results were obtained with bilaterally or proximally bent Kirschner wires. Regarding length, the tension band was placed closely (within 25% of the patella length) in 124 patients and distantly in 46 patients. The rates of loss of reduction and implant breakage were significantly higher in the distantly placed tension bands. Regarding depth, 37 patellar fractures were fixed with the Kirschner wires at the superficial one third of the patellae while the K- wires at the middle layer of patella were used in the remaining 133 patellar fractures. A significantly higher rate of minor loss of reduction was obtained using the superficial Kirschner wires. The modified tension band technique for transverse patella fractures provides favourable clinical outcomes, with low failure (5%) and infection (2%) rates. Implant irritation is the major complication, and almost half of cases require implant removal. The location of the tension band with respect to the superior and inferior border of the patella plays an important role in clinical outcomes. Placing the wire close to the patella may prevent major loss of reduction and implant breakage. Superficially placed Kirschner wires also affect clinical outcomes by increasing the rate of minor loss of reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A conservative approach to pediatric mandibular fracture management: outcome and advantages.

    PubMed

    Khatri, Amit; Kalra, Namita

    2011-01-01

    Pediatric mandibular fractures are rare and their treatment remains controversial. Management is extremely complicated in mixed dentition as it is inherently dynamic and unstable. Treatment options include soft diet, intermaxillary fixation with eyelet wires, arch bars, circummandibular wiring, or stents. Alternative options include open reduction and internal fixation through either an intraoral or extraoral approach. This case report describes and evaluates the conservative technique of acrylic splint in the treatment of pediatric mandible fracture in a 12-year-old female child. The patient with isolated mandibular fracture was treated with acrylic splint and interdental wiring followed by evaluation of clinical and radiographic healing as well as the somatosensory status. Patient demonstrated clinical union to her pre-injury occlusion by three to four weeks. Panoramic finding supported the finding of clinical examination throughout the study. High osteogenic potential of the pediatric mandible allowed conservative management to be successful in this case.

  2. Is Surgical Navigation Useful During Closed Reduction of Nasal Bone Fractures?

    PubMed

    Kim, Seon Tae; Jung, Joo Hyun; Kang, Il Gyu

    2017-05-01

    To report the case of a 42-year-old woman with a nasal bone fracture that was easily treated using a surgical navigation system. In this clinical report, the authors suggest that intraoperative surgical navigation systems are useful diagnostically and for localizing sites of nasal bone fractures exactly. The patient underwent successful closed reduction of the nasal bone fracture. Surgical navigation is a useful tool for identifying nasal bone fracture locations and for guiding closed reduction. Surgical navigation is recommended when nasal bone fractures are complicated or not well reduced using the ordinary method.

  3. [Arthroscopy-guided fracture management. Ankle joint and calcaneus].

    PubMed

    Schoepp, C; Rixen, D

    2013-04-01

    Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.

  4. Postoperative Evaluation of Reduction Loss in Proximal Humeral Fractures: A Comparison of Plain Radiographs and Computed Tomography.

    PubMed

    Jia, Xiao-Yang; Chen, Yan-Xi; Qiang, Min-Fei; Zhang, Kun; Li, Hao-Bo; Jiang, Yu-Chen; Zhang, Yi-Jie

    2017-05-01

    To compare postoperative CT images with plain radiographs for measuring prognostic factors of reduction loss of fractures of the proximal part of the humerus. A total of 65 patients who sustained fractures of the proximal humerus treated with locking plates from June 2012 to October 2015 were retrospectively analyzed. There were 24 men and 41 women, with a mean age of 60.0 years (range, 22-76 years). According to the Neer classification system of proximal humeral fracture, there were 26 two-part, 27 three-part and 12 four-part fractures of the proximal part of the humerus, and all fractures were treated with open reduction and internal fixation (ORIF) using locked plating. All postoperative CT images and plain radiographs of the patients were obtained. Prognostic factors of the reduction loss were the change of neck shaft angle (NSA) and the change of humeral head height (HHH). The change of NSA and HHH were evaluated by the difference between postoperative initial and final follow-up measurement. Reduction loss was defined as the change ≥10° for NSA or ≥5 mm for HHH. The NSA and HHH were measured using plain radiographs and 3-D CT images, both initially and at final follow-up. The paired t-test was used for comparison of NSA, change of NSA, HHH, and change of HHH between two image modalities. The differences between two image modalities in the assessment of reduction loss were examined using the χ 2 -test (McNemar test). Intraclass correlation coefficients (ICC) were used to assess the intra-observer and inter-observer reliability. 3-D CT images (ICC range, 0.834-0.967) were more reliable in all parameters when compared with plain radiographs (ICC range, 0.598-0.915). Significant differences were found between the two image modalities in all parameters (plain radiographs: initial NSA = 133.6° ± 3.8°, final NSA = 130.0° ± 1.9°, initial HHH = 17.9 ± 0.9 mm, final HHH = 15.8 ± 1.5 mm; 3-D CT: initial NSA = 131.4° ± 3.4°, final NSA = 128.8° ± 1.7°, initial HHH = 16.8 ± 1.2 mm, final HHH = 14.5 ± 1.1 mm; all P < 0.05). In the assessment of reduction loss, the percentage was 16.9% (11/65) for the plain radiographs and 7.7% (5/65) for the 3-D CT scans (P < 0.05). For the 5 patients with reduction loss, which were observed by two imaging modalities, the mean Constant-Murley score was 61.0 ± 1.6. The patients with reduction loss, observed only in plain radiographs but not CT images, had good shoulder function (Constant-Murley score: 82.7 ± 1.0). Our data reveal that 3-D CT images are more reliable than plain radiographs in the assessment of the prognostic factors of reduction loss of fractures of the proximal part of the humerus with treatment of locking plates; this reliable CT technique can serve as an effective guideline for the subsequent clinical management of patients. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  5. [The clinical effect of anti-rotation reduction internal fixator on the treatment of fresh thoracolumbar spine fracture].

    PubMed

    Pan, Xianming; Quan, Yi; Tan, Yingjun; Zhang, Bo; Wang, Yuanshan; Huang, Tong; Ma, Zehui; Liao, Dongfa; Li, Ting; Liu, Jinbiao

    2005-03-15

    To evaluate the effect of self-designed anti-rotation reduction internal fixator (ARRIF) on treating different spine segment fracture. From August 1999 to March 2003, 76 patients(48 males and 28 females, aged from 22 to 59 with an average of 34.1) with thoracolumbar fracture were operatively treated by ARRIF. The follow-up period ranged from 6 to 21 months (15 months in average). Classification according to injury segment: flexion compression fracture 27 cases, burst fracture 42 cases, flexion distraction injury 3 cases, flexion revolving type fracture dislocation 2 cases, shear force type dislocation 2 cases. Classification according Frankel's grade: A grade 16 cases, B grade 15 cases, C grade 27 cases, D grade 10 cases, E grade 8 cases. Operation duration, volume of bleeding, incidence post-operation complication and effect of reduction-fixation were observed. The operation duration of ARRIF was 1.2 h in average, and there was about 200 ml volume of bleeding during operation. The nerve function showed one Frankel's grade improvement after operation were as follows: A grade 8 cases (50%), B grade 11 cases (73.3%), C grade 20 cases (74.1%), D grade 3 cases (30%); 2 Frankel's E cases have no nerve function changes. The nerve function damage have no aggravation in all the patients, the postoperation Cobb's angle was averagely corrected 22 degrees. The horizontal displacement of dislocation vertebrae was averagely corrected 28% in sagittal plane, the statistical analysis had significant variance (P < 0.01). ARRIF had no complications of the breakage of screws and rods. ARRIF proves to be a valid internal fixator in reducing and fixing different thoracic lumbar segment spine fracture.

  6. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P <0.000 01) and total complications( I (2)=0%, RR =0.71, 95% CI 0.59-0.85, Z =3.65, P =0.000 3) ), DASH scores( I (2)=37%, MD =-5.67, 95% CI -8.31--3.04, Z =4.22, P <0.000 1) and volar tilt( I (2)=78%, MD =2.29, 95% CI 0.33-4.24, Z =2.30, P =0.02)( P <0.05) at the end of follow-up period were noted. There were no statistically significant differences observed between two approaches with respect to the clinical outcomes (grip strength, flexion, extension, pronation, supination, radial deviation and ulnar deviation) and radiographic outcome(radial length) at the end of follow-up period( P <0.05). Conclusion: Both open reduction and internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  7. Use of a real-size 3D-printed model as a preoperative and intraoperative tool for minimally invasive plating of comminuted midshaft clavicle fractures.

    PubMed

    Kim, Hyong Nyun; Liu, Xiao Ning; Noh, Kyu Cheol

    2015-06-10

    Open reduction and plate fixation is the standard operative treatment for displaced midshaft clavicle fracture. However, sometimes it is difficult to achieve anatomic reduction by open reduction technique in cases with comminution. We describe a novel technique using a real-size three dimensionally (3D)-printed clavicle model as a preoperative and intraoperative tool for minimally invasive plating of displaced comminuted midshaft clavicle fractures. A computed tomography (CT) scan is taken of both clavicles in patients with a unilateral displaced comminuted midshaft clavicle fracture. Both clavicles are 3D printed into a real-size clavicle model. Using the mirror imaging technique, the uninjured side clavicle is 3D printed into the opposite side model to produce a suitable replica of the fractured side clavicle pre-injury. The 3D-printed fractured clavicle model allows the surgeon to observe and manipulate accurate anatomical replicas of the fractured bone to assist in fracture reduction prior to surgery. The 3D-printed uninjured clavicle model can be utilized as a template to select the anatomically precontoured locking plate which best fits the model. The plate can be inserted through a small incision and fixed with locking screws without exposing the fracture site. Seven comminuted clavicle fractures treated with this technique achieved good bone union. This technique can be used for a unilateral displaced comminuted midshaft clavicle fracture when it is difficult to achieve anatomic reduction by open reduction technique. Level of evidence V.

  8. On the importance of aging to the crack growth resistance of human enamel.

    PubMed

    Yahyazadehfar, Mobin; Zhang, Dongsheng; Arola, Dwayne

    2016-03-01

    With improvements in oral health and an overall increase in quality of life, the percentage of fully or largely dentate seniors is increasing. Understanding the effects of aging on the mechanical properties of teeth is essential to the maintenance of lifelong oral health. In this investigation the effects of aging on the fracture toughness of human enamel were evaluated from incremental crack growth experiments performed on tissue of donor teeth representing "young" (17 ⩽ age ⩽ 25) and "old" (age ⩾ 55) age groups. Results showed that the old enamel exhibited significantly lower resistance to fracture than that of the young tissue in two orthogonal directions of crack growth. For crack growth transverse to the enamel rods, the fracture toughness of the old enamel (0.37 ± 0.15 MPa m(0.5)) was nearly 70% lower than that of tissue from the young teeth (1.23 ± 0.20 MPa m(0.5)). Based on results from a mechanistic analysis of crack growth, the reduction in fracture resistance is attributed to a decrease in the degree of extrinsic toughening. The practice of restorative dentistry should account for these changes in tooth tissues in the treatment of senior patients. The mechanical behavior of enamel has been studied for over 3 decades. Due to the limited volume of tissue available for evaluation, past work has been largely based on indentation methods. In this investigation we have evaluated the resistance to fracture of human enamel using a conventional fracture mechanics approach and incremental crack growth. We compared the fracture resistance of cuspal enamel obtained from the teeth of representative "young" and "old" donor groups. Our results show that there is a substantial reduction in the resistance to fracture with age, that it is anisotropic, and that the degradation is more severe than that which occurs to dentin. As such, we feel this work is a significant contribution to the field. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Titanium Mesh Shaping and Fixation for the Treatment of Comminuted Mandibular Fractures.

    PubMed

    Dai, Jiewen; Shen, Guofang; Yuan, Hao; Zhang, Wenbin; Shen, Shunyao; Shi, Jun

    2016-02-01

    Treating comminuted mandibular fractures remains a challenge. In this study, we used titanium mesh to treat comminuted mandibular fractures. Nine patients with traumatically comminuted mandibular fractures who received open reduction and internal stable fixation with titanium mesh were retrospectively reviewed. Open reduction-internal stable fixation was performed 7 to 10 days after primary debridement of the facial trauma. After the fractured mandible and the displaced fragments were reduced, the titanium mesh was reshaped according to the morphology of the mandible, and the reduced bone fragments were fixed with the reshaped titanium mesh and screws. Then, the surgical effects were evaluated during routine follow-up. Most of the displaced fragments were preserved and exhibited a favorable shaping ability in restoring the morphology of the mandible during surgery. No intraoperative complications were encountered. In addition, all patients were infection free, with no obvious resorption in the fixed fragments after surgery. The mandible also exhibited favorable morphology and offered sufficient bone mass for dental implantation or a denture prosthesis. We conclude that titanium mesh shaping and fixation can effectively treat comminuted mandibular fractures with little bone fragment loss, little soft tissue exposure, a low infection rate, and favorable mandibular morphology. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Timing of Surgical Reduction and Stabilization of Talus Fracture-Dislocations.

    PubMed

    Buckwalter V, Joseph A; Westermann, Robert; Mooers, Brian; Karam, Matthew; Wolf, Brian

    Talus fractures with associated dislocations are rare but have high rates of complications, including avascular necrosis (AVN). Management of these injuries involves urgent surgical reduction and fixation, although there are no definitive data defining an operative time frame for preserving the blood supply and preventing complications. To determine the effect of time to surgical reduction of talus fractures and talus fracture-dislocations on rates of AVN and posttraumatic osteoarthritis (PTOA), we retrospectively reviewed talus fractures surgically managed at a level I trauma center during the 10-year period 2003 to 2013. Operative reports were obtained and reviewed, and 3 independent reviewers, using the Hawkins and AO/OTA (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association) systems, classified the injuries on plain radiographs. Analysis of AO/OTA 81 fractures with associated tibiotalar, subtalar, or talonavicular dislocations was performed. Primary outcomes were presence of AVN/PTOA and subsequent arthrodesis of tibiotalar or subtalar joints. We identified 106 surgically managed talus fractures. Rates of AVN/PTOA were 41% for all talus fractures and 50% for talus fracture-dislocations. Mean time to surgical reduction was not significant for development of AVN/PTOA for all talus fractures (P = .45) or talus fracture-dislocations (P = .29). There was no difference in age (P = .20), body mass index (P = .45), or polytrauma (P = .79) between patients who developed AVN and those who did not. Open fractures were significantly correlated with the development of AVN/PTOA (P = .009). Talar fracture-dislocations are devastating injuries with high rates of complications. Our data suggest there is no effect of time from injury to surgical reduction of talus fractures or talus fracture-dislocations on rates of AVN and PTOA.

  11. Evidence-based medicine: Mandible fractures.

    PubMed

    Morrow, Brad T; Samson, Thomas D; Schubert, Warren; Mackay, Donald R

    2014-12-01

    After studying this article, the participant should be able to: 1. Describe the anatomy and subunits of the mandible. 2. Review the cause and epidemiology of mandible fractures. 3. Discuss the preoperative evaluation and diagnostic imaging. 4. Understand the principles and techniques of mandible fracture reduction and fixation. The management of mandibular fractures has undergone significant improvement because of advancements in plating technology, imaging, and instrumentation. As the techniques in management continue to evolve, it is imperative for the practicing physician to remain up-to-date with the growing body of scientific literature. The objective of this Maintenance of Certification article is to present a review of the literature so that the physician may make treatment recommendation based on the best evidence available. Pediatric fractures have been excluded from this article.

  12. Intravenous regional anaesthesia (Bier's block) for pediatric forearm fractures in a pediatric emergency department-Experience from 2003 to 2014.

    PubMed

    Chua, Ivan S Y; Chong, S L; Ong, Gene Y K

    2017-12-01

    To evaluate the efficacy (length of stay in the emergency department and failure rate of Bier's block) and safety profile (death and major complications) of Bier's block in its use for manipulation and reduction of paediatric forearm fractures. This is a retrospective cohort study of pediatric patients in KKWomen's and Children's Hospital Children's Emergency Department with forearm fractures between Jan 2003 and Dec 2014 who underwent manipulation and reduction using Bier's block. Demographic data, time from registration to discharge, major complications and success rate were collated in a standardized data collection form. A subanalysis of the Bier's block group from 2009 to 2014 was performed and compared to a corresponding data set of paediatric patients who underwent manipulation and reduction of forearm fractures using ketamine for procedural sedation from 2009 to 2014. 1781 cases of paediatric forearm fractures were analysed. The mean age of patients in the Bier's block group was 12.0 years (range 5.5-17.8 years old). Of all patients undergoing Bier's block, 1471 out of 1781 patients were male (82.7%). The mean length of stay (LOS) in the department was 168±72min, measured from time of registration till departure. From our subanalysis of data from 2009 to 2014, the mean LOS for the Bier's block group was shorter - 170min compared to 238min for the ketamine group (P <0.0001). 2 patients had failed Bier's block which required a repeat procedural sedation using ketamine. 96% of patients who underwent Bier's block were discharged with an outpatient orthopaedic appointment. There were no deaths or major complications identified in our study. Bier's block is a safe technique for reduction of fractures when used in the appropriate population and fracture types, with a low failure rate and no major complications including death. Compared to the ketamine group, it has a shorter length of stay in the emergency department. We recommend the adoption of this practice for manipulation and reduction of pediatric forearm fractures in the Emergency Department with a formalised protocol to reduce and prevent any human errors that can potentially result in complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. The prevention of postmenopausal osteoporotic fractures: results of the Health Technology Assessment of a new antiosteoporotic drug.

    PubMed

    de Waure, Chiara; Specchia, Maria Lucia; Cadeddu, Chiara; Capizzi, Silvio; Capri, Stefano; Di Pietro, Maria Luisa; Veneziano, Maria Assunta; Gualano, Maria Rosaria; Kheiraoui, Flavia; La Torre, Giuseppe; Nicolotti, Nicola; Sferrazza, Antonella; Ricciardi, Walter

    2014-01-01

    The Health Technology Assessment (HTA) approach was applied to denosumab in the prevention of osteoporotic fractures in postmenopausal women. Epidemiological, clinical, technical, economic, organizational, and ethical aspects were considered. Medical electronic databases were accessed to evaluate osteoporosis epidemiology and therapeutical approaches. A budget impact and a cost-effectiveness analyses were performed to assess economic implications. Clinical benefits and patient needs were considered with respect to organizational and ethical evaluation. In Italy around four millions women are affected by osteoporosis and have a higher risk for fractures with 70,000 women being hospitalized every year. Bisphosphonates and strontium ranelate are recommended as first line treatment for the prevention of osteoporotic fractures. Denosumab is effective in reducing vertebral, nonvertebral, and hip/femoral fractures with an advantage of being administered subcutaneously every six months. The budget impact analysis estimated a reduction in costs for the National Health Service with the introduction of denosumab. Furthermore, the economic analysis demonstrated that denosumab is cost-effective in comparison to oral bisphosphonates and strontium ranelate. Denosumab can be administered in outpatients by involving General Practitioners in the management. Ethical evaluation is positive because of its efficacy and compliance. Denosumab could add value in the prevention of osteoporotic fractures.

  14. Value of Early Postoperative Computed Tomography Assessment in Ankle Fractures Defining Joint Congruity and Criticizing the Need for Early Revision Surgery.

    PubMed

    Palmanovich, Ezequiel; Brin, Yaron S; Kish, Benny; Nyska, Meir; Hetsroni, Iftach

    2016-01-01

    Previous investigators have questioned the reliability of plain radiographs in assessing the accuracy of ankle fracture reduction when these were compared with the computed tomography (CT) evaluation in the preoperative setting, in particular, in fractures with syndesmosis injuries or trimalleolar fragments. The role of CT assessment, however, has not been investigated in the early postoperative setting. In the early postoperative setting, reduction still relies most commonly on fluoroscopy and plain radiographs alone. In the present study, we hypothesized that early postoperative CT assessment of ankle fractures with syndesmosic injuries and posterior malleolar fragments can add valuable information about the joint congruity compared with plain radiographs alone and that this information could affect the decisions regarding the need for early revision surgery. A total of 352 consecutive operated ankle fractures were reviewed. Of these, 68 (19%) underwent early postoperative CT assessment and were studied further to identify the causes that prompted revision surgery. Of the 68 cases, despite acceptable reduction found on the plain radiographs, 20 (29%) underwent early (within 1 week) revision surgery after studying the CT scans, which revealed malreduction of the syndesmosis, malreduction of the posterior lip fragment, and intra-articular fragments. We concluded that in ankle fractures involving disruptions of the syndesmosis or posterior malleolar fragments, early postoperative CT assessment could be justified, because it will reveal malreduction and prompt early revision intervention for a substantial proportion of these patients. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. [Curative effect analysis on closed reduction and external fixator under local anesthesia for the treatment of intertrochanteric fracture in elderly patients with high-risk].

    PubMed

    Wang, Zeng-ping; Liu, Lin; Xue, Wen; Zhou, Hui-ru; Song, Yu-xin; Cai, Li-yang; Cheng, Xian-tang; Qian, Yao-wen

    2016-06-01

    To explore clinical efficacy of closed reduction and external fixation under local anesthesia for the treatment of high-risk elderly patients with intertrochanteric fracture. From March 2013 to March 2015, 10 patients with intertrochanteric fractures treated with closing reduction and external fixator under local anesthesia were analyszed, including 4 males and 6 females, aged from 69 to 88 years old with an average of 75.2 years old. All fractures were caused by injury and classified to type I (5 cases), II (3 cases), and V (2 cases) according to Evans classification. According to American Society of Anesthesiologists (ASA), 6 cases were type III and 4 cases were type IV. Blood loss,operative time,hospital stays, postoperative complications, ambulation time and fracture healing time were observed, and Harris scoring were used to evaluate hip joint function. All patients were followed up from 3 to 23 months with an average of 13.1 months. One patient with chronic obstructive pulmonary disease died for non-operation reason at 4 months after operation, the other fractures were healed at stage I, the mean fracture healing time was 5.6 months. There were no coxa vara, lower limb venous thrombosis, loosen and remove of needle passage. The average operative time was 46 min, blood loss was (35.00 ± 8.46) ml without blood transfusion. One patient was occurred pulmonary infection and stent-tract infection on the 2 nd and 3 rd day after operation, and improved with active anti-infection and dressing change; the other patients gone to ground activity at 4.2 d after operation. The patients stayed hospital for 10.6 d on average. According to Harris scoring at final following-up, the total score was 83.42 ± 3.27, 3 cases obtained excellent results, 5 cases good and 1 case poor. Closed reduction and external fixation under local anesthesia in treating high-risk elderly patients with intertrochanteric fracture,which has advantages of shorter operative time, less blood loss, good recovery of postoperative function, is a safe, stable and economic method.

  16. Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures

    PubMed Central

    Taylor, Benjamin C.; Hansen, Dane C.; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel

    2016-01-01

    Background Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. Methods In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Results Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. Conclusions This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted. PMID:27528840

  17. The Role of Organic Proteins on the Crack Growth Resistance of Human Enamel

    PubMed Central

    Yahyazadehfar, Mobin; Arola, Dwayne

    2015-01-01

    With only 1% protein by weight, tooth enamel is the most highly mineralized tissue in mammals. The focus of this study was to evaluate contributions of the proteins on the fracture resistance of this unique structural material. Sections of enamel were obtained from the cusps of human molars and the crack growth resistance was quantified using a conventional fracture mechanics approach with complementary finite element analysis. In selected specimens the proteins were extracted using a potassium hydroxide treatment. Removal of the proteins resulted in approximately 40% decrease in the fracture toughness with respect to the fully proteinized control. The loss of organic content was most detrimental to the extrinsic toughening mechanisms, causing over 80% reduction in their contribution to the total energy to fracture. This degradation occurred by embrittlement of the unbroken bridging ligaments and consequent reduction in the crack closure stress. Although the organic content of tooth enamel is very small, it is essential to crack growth toughening by facilitating the formation of unbroken ligaments and in fortifying their potency. Replicating functions of the organic content will be critical to the successful development of bio-inspired materials that are designed for fracture resistance. PMID:25805107

  18. Results of operative treatment of avulsion fractures of the iliac crest apophysis in adolescents.

    PubMed

    Li, Xigong; Xu, Sanzhong; Lin, Xiangjin; Wang, Quan; Pan, Jun

    2014-04-01

    Avulsion fracture of the iliac crest apophysis is a rare condition that commonly occurs in adolescent athletes. Conservative treatment for this injury can produce excellent functional outcomes. However, the rehabilitation process requires a rather long immobilisation period. This study aimed to evaluate the use of cannulated screws for fixation of avulsion fractures of iliac crest apophysis. Ten patients with avulsion fractures of iliac crest apophysis were treated by open reduction and internal fixation using cannulated screws. The mean age of patients was 14.6 years (range, 13-15 years). The mean intraoperative blood loss was 14.9 ml (range, 10-25 ml). The mean operative time was 40.3 min (range, 33-52 min). The mean follow-up period was 11.2 months (range, 6-20 months). At the 4-week follow-up, all patients returned to previously normal activity without pain and had no evidence of lower extremity muscle weakness. At the final follow-up, all patients resumed their athletic activity without any complications. Open reduction and internal fixation for the treatment of avulsion fracture of iliac crest apophysis can be recommended for patients requiring rapid rehabilitation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. How to improve retromandibular transmasseteric anteroparotid approach for mandibular condylar fractures: our clinical experience.

    PubMed

    Salgarelli, A C; Anesi, A; Bellini, P; Pollastri, G; Tanza, D; Barberini, S; Chiarini, L

    2013-04-01

    Fractures of the mandibular condyle are common and account for 25-35% of all mandibular fractures reported in the literature. Even with the development of a consensus on the preference for open reduction and internal fixation of these fractures, the clinician is still faced with a dilemma concerning the optimal approach to the ramus-condyle unit. Limited access and injury to the facial nerve are the most common problems. The most commonly used extraoral approaches are the submandibular, retromandibular and preauricular methods. In this study, we propose a modified cosmetic preauricular incision with a short end in the neck, to improve the transmasseteric anteroparotid (TMAP) approach previously described by Wilson et al. in 2005. We retrospectively analysed 13 patients treated in our department for mandibular condylar fractures. Post-operative complications, occlusal status, interincisal opening and joint tenderness were evaluated at 3 months after surgery. The wider skin incision described here provides a convenient approach for open reduction and rigid internal fixation, and good results were obtained. The follow-up ranged from 6 to 40 months. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Integration of computer-assisted fracture reduction system and a hybrid 3-DOF-RPS mechanism for assisting the orthopedic surgery

    NASA Astrophysics Data System (ADS)

    Irwansyah; Sinh, N. P.; Lai, J. Y.; Essomba, T.; Asbar, R.; Lee, P. Y.

    2018-02-01

    In this paper, we present study to integrate virtual fracture bone reduction simulation tool with a novel hybrid 3-DOF-RPS external fixator to relocate back bone fragments into their anatomically original position. A 3D model of fractured bone was reconstructed and manipulated using 3D design and modeling software, PhysiGuide. The virtual reduction system was applied to reduce a bilateral femoral shaft fracture type 32-A3. Measurement data from fracture reduction and fixation stages were implemented to manipulate the manipulator pose in patient’s clinical case. The experimental result presents that by merging both of those techniques will give more possibilities to reduce virtual bone reduction time, improve facial and shortest healing treatment.

  1. [Outcome of endoscopically assisted surgical treatment of mandibular condyle fractures: a retrospective study of 22 patients].

    PubMed

    Prade, V; Seguin, P; Boutet, C; Alix, T

    2014-12-01

    The condylar region is a frequent localization of mandibular fractures; there are various types of management. Mini-invasive endoscopic surgery is an alternative to open reduction. We had as goal to evaluate the outcome of this technique. We performed a monocentric retrospective study of patients consecutively operated for a condylar fracture (type II to V in the Spiessl and Schroll classification) with intraoral route and endoscopic assistance, during 30 months. We assessed the functional and radiological outcomes, and the complications. Twenty-two patients (25 fractures) were included. Seventeen patients (19 fractures) could be followed (mean follow-up: 16.7 months). The mean values were: interincisal opening, 45mm (±8.4); protrusion, 8.3mm (±1.9); ipsilateral excursion of the jaw: 8.6mm (±2); contralateral excursion: 8.7mm (±4). Three routes were used combined with a preauricular approach. The fracture reduction was good for 10 of the 19 fractures and poor for 3. The complications were: 3 cases of infection, 1 case of fixation failure with good consolidation; for combined approaches: 2 cases of temporary facial palsy and 2 cases of Frey syndrome. Endoscopic assistance for the surgical management of the fracture of mandibular condyle is a reliable technique, with a good functional outcome, and a low rate of specific complications, especially for facial nerve lesion or esthetic outcome. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  2. The effects of extracorporeal shockwave on acute high-energy long bone fractures of the lower extremity.

    PubMed

    Wang, Ching-Jen; Liu, Hao-Chen; Fu, Te-Hu

    2007-02-01

    High-energy long bone fractures of the lower extremity are at risk of poor fracture healing and high rate of non-union. Extracorporeal shockwave was shown effective to heal non-union of long bone fracture. However, the effect of shockwave on acute fractures is unknown. The purpose of this study was to investigate the effects of shockwave on acute high-energy fractures of the lower extremity. Between January and October 2004, 56 patients with 59 acute high-energy fractures were enrolled in this study. Patients were randomly divided into two groups with 28 patients with 28 fractures in the study group and 28 patients with 31 fractures in the control group. Both groups showed similar age, gender, type of fracture and follow-up time. Patients in the study group received open reduction and internal fixation and shockwave treatment immediately after surgery on odd-numbered days of the week, whereas, patients in the control group received open reduction and internal fixation without shockwave treatment on even-numbered days of the week. Postoperative managements were similarly performed in both groups including crutch walking with non-weight bearing on the affected limb until fracture healing shown on radiographs. The evaluation parameters included clinical assessments of pain score and weight bearing status of the affected leg and serial radiographs at 3, 6 and 12 months. The primary end-point is the rate of non-union at 12 months, and the secondary end point is the rate of fracture healing at 3, 6 and 12 months. At 12 months, the rate of non-union was 11% for the study group versus 20% for the control group (P < 0.001). Significantly, better rate of fracture healing was noted in the study group than the control group at 3, 6 and 12 months (P < 0.001). Extracorporeal shockwave is effective on promoting fracture healing and decreasing the rate of non-union in acute high-energy fractures of the lower extremity.

  3. [Effect factors analysis of knee function recovery after distal femoral fracture operation].

    PubMed

    Bei, Chaoyong; Wang, Ruiying; Tang, Jicun; Li, Qiang

    2009-09-01

    To investigate the effect factors of knee function recovery after operation in distal femoral fractures. From January 2001 to May 2007, 92 cases of distal femoral fracture were treated. There were 50 males and 42 females, aged 20-77 years old (average 46.7 years old). Fracture was caused by traffic accident in 48 cases, by falling from height in 26 cases, by bruise in 12 cases and by tumble in 6 cases. According to Müller's Fracture classification, there were 29 cases of type A, 12 cases of type B and 51 cases of type C. According to American Society of Anesthesiologists (ASA) classification, there were 21 cases of grade I, 39 cases of grade II, 24 cases of grade III, and 8 cases of grade IV. The time from injury to operation was 4 hours to 24 days with an average of 7 days. Anatomical plate was used in 43 cases, retrograde interlocking intramedullary nail in 37 cases, and bone screws, bolts and internal fixation with Kirschner pins in 12 cases. After operation, the HSS knee function score was used to evaluate efficacy. Ten related factors were applied for statistical analysis, to knee function recovery after operation in distal femoral fractures, such as age, sex, preoperative ASA classification, injury to surgery time, fracture type, treatment, reduction quality, functional exercise after operation, whether or not CPM functional training and postoperative complications. Wound healed by first intention in 88 cases, infection occurred in 4 cases. All patients followed up 16-32 months with an average of 23.1 months. Clinical union of fracture was achieved within 3-7 months after operation. Extensor device adhesions and the scope of activities of <80 degrees occurred in 29 cases, traumatic arthritis in 25 cases, postoperative fracture displacement in 6 cases, mild knee varus or valgus in 7 cases and implant loosening in 6 cases. According to HSS knee function score, the results were excellent in 52 cases, good in 15 cases, fair in 10 cases and poor in 15 cases with an excellent and good rate of 72.83%. Single factor analysis showed that age, preoperative ASA classification, fracture type, reduction quality, whether or not CPM functional exercise, and postoperative complications were significantly in knee function recovery (P < 0.05). logistic regression analysis showed that the fracture type, quality of reduction, whether or not CPM functional exercise, and age were major factors in the knee joint function recovery. Age, preoperative ASA classification, fracture type, reduction quality, and whether or not CPM functional training, postoperative complications factors may affect the knee joint function recovery. Adjustment to the patient's preoperative physical status, fractures anatomic reduction and firm fixation, early postoperative active and passive functional exercises, less postoperative complications can maximize the restoration of knee joint function.

  4. 3D printing-based minimally invasive cannulated screw treatment of unstable pelvic fracture.

    PubMed

    Cai, Leyi; Zhang, Yingying; Chen, Chunhui; Lou, Yiting; Guo, Xiaoshan; Wang, Jianshun

    2018-04-04

    Open reduction and internal fixation of pelvic fractures could restore the stability of the pelvic ring, but there were several problems. Minimally invasive closed reduction cannulated screw treatment of pelvic fractures has lots advantages. However, how to insert the cannulated screw safely and effectively to achieve a reliable fixation were still hard for orthopedist. Our aim was to explore the significance of 3D printing technology as a new method for minimally invasive cannulated screw treatment of unstable pelvic fracture. One hundred thirty-seven patients with unstable pelvic fractures from 2014 to 2016 were retrospectively analyzed. Based on the usage of 3D printing technology for preoperative simulation surgery, they were assigned to 3D printing group (n = 65) and control group (n = 72), respectively. These two groups were assessed in terms of operative time, intraoperative fluoroscopy, postoperative reduction effect, fracture healing time, and follow-up function. The effect of 3D printing technology was evaluated through minimally invasive cannulated screw treatment. There was no significant difference in these two groups with respect to general conditions, such as age, gender, fracture type, time from injury to operation, injury cause, and combined injury. Length of surgery and average number of fluoroscopies were statistically different for 3D printing group and the control group (p < 0.01), i.e., 58.6 vs. 72.3 min and 29.3 vs. 37 min, respectively. Using the Matta radiological scoring systems, the reduction was scored excellent in 21/65 cases (32.3%) and good in 30/65 cases (46.2%) for the 3D printing group, versus 22/72 cases (30.6%) scored as excellent and 36/72 cases (50%) as good for the control group. On the other hand, using the Majeed functional scoring criteria, there were 27/65 (41.5%) excellent and 26/65 (40%) good cases for the 3D printing group in comparison to 30/72 (41.7%) and 28/72 (38.9%) cases for the control group, respectively. This suggests no significant difference between these two groups about the function outcomes. Full reduction and proper fixation of the pelvic ring and reconstruction of anatomical morphology are of great significance to patients' early functional exercise and for the reduction of long-term complications. This retrospective study has demonstrated the 3D printing technology as a potential approach for improving the diagnosis and treatment of pelvic fractures. The study was retrospectively registered at the Chinese Clinical Trial Registry, number: ChiCTR-TRC-17012798, trial registration date: 26 Sept. 2017.

  5. Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures.

    PubMed

    Kumar, Sanjay; Khan, A N; Sonanis, S V

    2016-12-01

    Fracture of the distal radius is a common clinical problem. Complex fracture requires open reduction and stabilization with plating to restore anatomy. Dorsal plating has advantages of buttressing the fracture better but often complicated with tendon problems as per literature. The rate of complications however, was not compared between the low-profile dorsal and the volar plates. This was a retrospective study on seventy one patients with dorsally angulated or displaced distal radius fractures, who underwent fixation of fractures with either dorsal or volar locking plate from Jan - Nov 2012. Preoperative radiographs were classified based on Universal and Fernandez classification. Postoperative radiographs were assessed for anatomical restoration of Radial length, radial inclination and volar tilt. Tendon and nerve related complications were assessed and functional evaluation was performed on the basis of PRWE (Patient related wrist evaluation) score. Both groups were matched for their demographic profile and fracture types (p 0.033). Dorsal plating group had 89% excellent/good restoration and fair in 11%. Volar group had 96% excellent/good restoration and fair in 4%. Statistical analysis was performed with unpaired t test for radiographic parameters. Three patients had tendon related complications in dorsal plating group; two patients in volar group had nerve related complications. Functional outcome with PRWE was comparable between two groups. Results with low profile dorsal plating were comparable to volar plating. Therefore dorsal plating can be used as an alternative method when dorsal buttressing of comminuted fracture is required, especially with concomitant osteoporosis.

  6. Simplified data reduction methods for the ECT test for mode 3 interlaminar fracture toughness

    NASA Technical Reports Server (NTRS)

    Li, Jian; Obrien, T. Kevin

    1995-01-01

    Simplified expressions for the parameter controlling the load point compliance and strain energy release rate were obtained for the Edge Crack Torsion (ECT) specimen for mode 3 interlaminar fracture toughness. Data reduction methods for mode 3 toughness based on the present analysis are proposed. The effect of the transverse shear modulus, G(sub 23), on mode 3 interlaminar fracture toughness characterization was evaluated. Parameters influenced by the transverse shear modulus were identified. Analytical results indicate that a higher value of G(sub 23) results in a low load point compliance and lower mode 3 toughness estimation. The effect of G(sub 23) on the mode 3 toughness using the ECT specimen is negligible when an appropriate initial delamination length is chosen. A conservative estimation of mode 3 toughness can be obtained by assuming G(sub 23) = G(sub 12) for any initial delamination length.

  7. The development of in situ fracture toughness evaluation techniques in hydrogen environment

    DOE PAGES

    Wang, John Jy-An; Ren, Fei; Tan, Tin; ...

    2014-12-19

    Reliability of hydrogen pipelines and storage tanks is significantly influenced by the mechanical performance of the structural materials exposed in the hydrogen environment. Fracture behavior and fracture toughness are of specific interest since they are relevant to many catastrophic failures. However, many conventional fracture testing techniques are difficult to be realized under the presence of hydrogen. Thus it is desired to develop novel in situ techniques to study the fracture behavior of structural materials in hydrogen environments. In this study, special testing apparatus were designed to facilitate in situ fracture testing in H 2. A torsional fixture was developed tomore » utilize an emerging fracture testing technique, Spiral Notch Torsion Test (SNTT). The design concepts will be discussed. Preliminary in situ testing results indicated that the exposure to H 2 significantly reduces the fracture toughness of 4340 high strength steels by up to 50 percent. Furthermore, SNTT tests conducted in air demonstrated a significant fracture toughness reduction in samples subject to simulated welding heat treatment using Gleeble, which illustrated the effect of welding on the fracture toughness of this material.« less

  8. [Application of temporomandibular joint dics reduction in the operation of condylar sagittal fracture].

    PubMed

    Wenli, Zeng; Wuchao, Zhou; Jingkun, Zhang; Yisen, Shao; Weihong, Xi

    2017-10-01

    To explore the selection of temporomandibular joint (TMJ) disc reduction and fixation methods in condylar sagittal fracture surgery. A total of 36 patients with condylar fractures were chosen. The follow-up period was more 6 months. All 36 cases of condylar sagittal fracture were fixed with long screw. In the operation, the displaced joint disc was repositioned and fixed. The fixed method included direct suture (22 cases) and anchorage (14 cases). Clinical followups were performed before surgery and 1 month, 3 months, 6 months and 1 year after surgery. Clinicians recorded data related to the Fricton craniomandibular index (CMI) and evaluated the postoperative joint function during followup before surgery and 6 months after surgery. In both groups, function of TMJ significantly improved after surgery. The CMI decreased from 0.213±0.162 and 0.273±0.154 to 0.059±0.072 and 0.064±0.068 (P<0.05), respectively. No statistical difference was observed between the two groups in palpation index (PI), dysfunction index (DI) and CMI (P>0.05) before or after surgery. Both methods could effectively improve the dysfunction of the TMJ caused by trauma. The selection of joint disc reduction and fixation methods is based on the displacement and damage degree of the joint disc.

  9. Fixation of zygomatic and mandibular fractures with biodegradable plates

    PubMed Central

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    Context: In this prospective study, 13 randomly selected patients underwent treatment for zygomatic–complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. Aims: To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. Materials and Methods: In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Statistical Analysis Used: Descriptives, Frequencies, and Chi-square test were used. Results: In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Conclusions: Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome. PMID:23662255

  10. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID): protocol for a randomized clinical multi-center trial.

    PubMed

    Bartl, Christoph; Stengel, Dirk; Bruckner, Thomas; Rossion, Inga; Luntz, Steffen; Seiler, Christoph; Gebhard, Florian

    2011-03-22

    Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF) with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation.Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius) is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool.The primary objective is to determine differences in the Short Form 36 (SF-36) Physical Component Score (PCS) between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH) instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery), as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture involves a central statistical unit, an independent monitoring institute, and a data safety monitoring board. Following approval by the institutional review boards of all participating centers, conduct and reporting will strictly adhere to national and international rules, regulations, and recommendations (e.g., Good Clinical Practice, data safety laws, and EQUATOR/CONSORT proposals). To our knowledge, ORCHID is the first multicenter RCT designed to assess quality of life and functional outcomes following operative treatment compared to conservative treatment of complex, intra-articular fractures of the distal radius in elderly patients. The results are expected to influence future treatment recommendations and policies on an international level. ISRCTN: ISRCTN76120052 Registration date: 31.07.2008; Randomization of first patient: 15.09.2008.

  11. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures.

    PubMed

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2015-09-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3-12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact.

  12. Consequences of quality of reduction on osteosynthesis complications and quality of life in elderly patients with subtrochanteric fracture.

    PubMed

    Codesido-Vilar, P; Mejía-Casado, A; Riego-Fernández, J; Rodriguez-Casas, N; García-Cabanas, S; Rivas-Felice, J; García-Quevedo, L

    2018-05-18

    To compare results in terms of orthopaedic complications and quality of life in elderly patients with subtrochanteric fracture treated with intramedullary nailing according to fracture reduction status. A prospective cohort study including 90 elderly patients with subtrochanteric fractures of the femur treated with a cephalomedullary nail, with a minimum 1-year follow up. The inclusion criteria were: aged 60 years or older, without severe cognitive dysfunction and independent ambulatory capability before the fracture. We defined 3different groups in relation to fracture reduction status: good, acceptable and poor, according to modified criteria from Baumgartner et al. We compared clinical and surgical characteristics and healthy quality of life, social function and mobility according to the EQ-5D, Jensen Index and Mobility Score of Parker and Palmer questionnaires. We found differences in time to union, better in the good reduction group (P=.002); need for open reduction, more frequent in the good reduction group (P<.001), and in postoperative complications, more frequent in the poor reduction group (P=.001). We found no significant differences between the 3groups regarding scores in quality of life, social function and mobility. Reduction in subtrochanteric fractures in older people is key to obtaining better clinic and surgical results, improving time to union and decreasing surgical complications. Exposure of the focus fracture seems to be a safe manoeuvre. Quality of life had substantially deteriorated n these patients, but a there was a tendency, although not statistically significant, for it to improve in patients after good surgical reduction. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Do instability markers predict satisfactory reduction and requirement for later surgery in emergency department patients with wrist fracture?

    PubMed

    Winayak, Amar; Gossat, Alyza; Cooper, Jenny; Ritchie, Peter; Lim, Wei; Klim, Sharon; Kelly, Anne-Maree

    2018-02-01

    Research suggests that the presence of instability markers in patients with displaced distal radial fractures is associated with poorer outcome. Our aims were to determine whether the presence of previously defined instability markers could predict the likelihood of successful ED reduction and requirement for a secondary procedure after ED reduction. Retrospective cohort study performed by medical record review. Adult ED patients coded as having an isolated wrist fracture and having fracture reduction in ED were eligible for inclusion. Data collected included demographics, history of osteoporosis, mechanism of injury, radiological features on X-rays and performance of a secondary procedure. Outcomes of interest were the rate of successful fracture reduction in ED (against defined radiological criteria), the rate of secondary procedures and the association between the number of defined instability risk factors and successful reduction and performance of a secondary surgical procedure. Analysis was by χ 2 test, receiver operating characteristic curve, logistic regression analyses. Three hundred and nineteen patients were studied; median age 62 years, 77% female. Sixty-five per cent of patients had satisfactory fracture reduction in ED (95% CI 59%-70%). Eighty-six patients underwent a secondary procedure to reduce/stabilise their fracture (28%, 95% CI 23%-33%). Younger age, lack of satisfactory ED reduction and increased number of instability factors were independently predictive of the performance of a secondary procedure. Instability risk factors are common in patients with wrist fractures requiring reduction in ED. The number of instability factors is not a strong predictor of the performance of secondary procedures. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  14. Effect of Cortical Screw Diameter on Reduction and Stabilization of Type III Distal Phalanx Fractures: An Equine Cadaveric Study.

    PubMed

    Kay, Alastair T; Durgam, Sushmitha; Stewart, Matthew; Joslyn, Stephen; Schaeffer, David J; Horn, Gavin; Kesler, Richard; Chew, Peter

    2016-11-01

    To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. Cadaveric experimental study. Hooves from 12 adult horses (n=24). Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at P<.05. Type III distal phalanx fractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load. © Copyright 2016 by The American College of Veterinary Surgeons.

  15. Open reduction-internal fixation of a navicular body fracture with dorsal displacement of the first and second cuneiforms: a case report.

    PubMed

    Andersen, Robert C; Neiderer, Katherine; Martin, Billy; Dancho, James

    2013-01-01

    Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. He underwent open reduction internal fixation of the navicular body fracture successfully but failed adequate reduction of the navicular cuneiform joint after ligamentous reconstruction. After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.

  16. Identification of fracture zones and its application in automatic bone fracture reduction.

    PubMed

    Paulano-Godino, Félix; Jiménez-Delgado, Juan J

    2017-04-01

    The preoperative planning of bone fractures using information from CT scans increases the probability of obtaining satisfactory results, since specialists are provided with additional information before surgery. The reduction of complex bone fractures requires solving a 3D puzzle in order to place each fragment into its correct position. Computer-assisted solutions may aid in this process by identifying the number of fragments and their location, by calculating the fracture zones or even by computing the correct position of each fragment. The main goal of this paper is the development of an automatic method to calculate contact zones between fragments and thus to ease the computation of bone fracture reduction. In this paper, an automatic method to calculate the contact zone between two bone fragments is presented. In a previous step, bone fragments are segmented and labelled from CT images and a point cloud is generated for each bone fragment. The calculated contact zones enable the automatic reduction of complex fractures. To that end, an automatic method to match bone fragments in complex fractures is also presented. The proposed method has been successfully applied in the calculation of the contact zone of 4 different bones from the ankle area. The calculated fracture zones enabled the reduction of all the tested cases using the presented matching algorithm. The performed tests show that the reduction of these fractures using the proposed methods leaded to a small overlapping between fragments. The presented method makes the application of puzzle-solving strategies easier, since it does not obtain the entire fracture zone but the contact area between each pair of fragments. Therefore, it is not necessary to find correspondences between fracture zones and fragments may be aligned two by two. The developed algorithms have been successfully applied in different fracture cases in the ankle area. The small overlapping error obtained in the performed tests demonstrates the absence of visual overlapping in the figures. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Comparison of fracture resistance of simulated immature teeth with an open apex using Biodentine and composite resin: An in vitro study.

    PubMed

    Zhabuawala, Murtuza Saifuddin; Nadig, Roopa R; Pai, Veena S; Gowda, Yashwanth

    2016-01-01

    To evaluate the fracture resistance in simulated immature teeth that had been backfilled using composite resin and Biodentine after using Biodentine as an apical plug material immediately and after 3 months of aging. Sixty extracted human maxillary central incisors were simulated in an immature open apex. The roots of all the specimens were then standardized to a length of 10 mm and canals were instrumented to obtain the radicular dentin thickness around 1.5 mm. All the specimens were then randomly divided into three groups of twenty teeth each. Group I (control) - 4 mm apical plug of Biodentine backfilled with thermoplasticized gutta-percha. Group II - 4 mm apical plug of Biodentine and then backfilled with ParaCore. Group III - completely filled with Biodentine. Ten samples from each group were randomly divided into two subgroups. In subgroup A: Specimens were stored for 1 week. In subgroup B: Specimens were stored in phosphate-buffered saline solution for 3 months and were subjected to universal testing machine. Statistical analysis was done using one-way analysis. No significant difference in fracture resistance between the groups was observed when tested immediately. After 3 months of aging, only Biodentine group showed a significant reduction in fracture resistance without significant reduction with other two groups. Biodentine group has shown a drastic reduction in fracture resistance after 3 months of aging, and hence cannot be recommended as a reinforcement material in immature teeth with thin dentin walls.

  18. Alendronate for fracture prevention in postmenopause.

    PubMed

    Holder, Kathryn K; Kerley, Sara Shelton

    2008-09-01

    Osteoporosis is an abnormal reduction in bone mass and bone deterioration leading to increased fracture risk. Alendronate (Fosamax) belongs to the bisphosphonate class of drugs, which act to inhibit bone resorption by interfering with the activity of osteoclasts. To assess the effectiveness of alendronate in the primary and secondary prevention of osteoporotic fractures in postmenopausal women. The authors searched Central, Medline, and EMBASE for relevant randomized controlled trials published from 1966 to 2007. The authors undertook study selection and data abstraction in duplicate. The authors performed meta-analysis of fracture outcomes using relative risks, and a relative change greater than 15 percent was considered clinically important. The authors assessed study quality through reporting of allocation concealment, blinding, and withdrawals. Eleven trials representing 12,068 women were included in the review. Relative and absolute risk reductions for the 10-mg dose were as follows. For vertebral fractures, a 45 percent relative risk reduction was found (relative risk [RR] = 0.55; 95% confidence interval [CI], 0.45 to 0.67). This was significant for primary prevention, with a 45 percent relative risk reduction (RR = 0.55; 95% CI, 0.38 to 0.80) and 2 percent absolute risk reduction; and for secondary prevention, with 45 percent relative risk reduction (RR = 0.55; 95% CI, 0.43 to 0.69) and 6 percent absolute risk reduction. For nonvertebral fractures, a 16 percent relative risk reduction was found (RR = 0.84; 95% CI, 0.74 to 0.94). This was significant for secondary prevention, with a 23 percent relative risk reduction (RR = 0.77; 95% CI, 0.64 to 0.92) and a 2 percent absolute risk reduction, but not for primary prevention (RR = 0.89; 95% CI, 0.76 to 1.04). There was a 40 percent relative risk reduction in hip fractures (RR = 0.60; 95% CI, 0.40 to 0.92), but only secondary prevention was significant, with a 53 percent relative risk reduction (RR = 0.47; 95% CI, 0.26 to 0.85) and a 1 percent absolute risk reduction. The only significance found for wrist fractures was in secondary prevention, with a 50 percent relative risk reduction (RR = 0.50; 95% CI, 0.34 to 0.73) and a 2 percent absolute risk reduction. For adverse events, the authors found no statistically significant difference in any included study. However, observational data raise concerns about potential risk for upper gastrointestinal injury and, less commonly, osteonecrosis of the jaw. At 10 mg of alendronate per day, clinically important and statistically significant reductions in vertebral, nonvertebral, hip, and wrist fractures were observed for secondary prevention. The authors found no statistically significant results for primary prevention, with the exception of vertebral fractures, for which the reduction was clinically important.

  19. Pediatric jaw fractures: indications for open reduction.

    PubMed

    Krausen, A S; Samuel, M

    1979-01-01

    Jaw fractures in children are generally managed without major surgical intervention. Closed reduction usually is sufficient to restore normal anatomy and function. The one inviolate principle is early treatment. During the past three years, four pediatric jaw fractures that required open reduction were treated. This mode of treatment was necessitated by the limitations imposed by pediatric dental anatomy and by the type of fractures encountered. In at least 24 months of follow-up, no dental problems have been seen.

  20. [Short-term effectiveness of minimally invasive percutaneous plate osteosynthesis in treatment of anterior pelvic ring fracture].

    PubMed

    Chen, Ming; Han, Zhimin; Li, Zhiyun; Cai, Qiangqiang; Tu, Junling

    2014-09-01

    To investigate the short-term effectiveness of minimally invasive percutaneous plate osteosynthesis (MIPPO) in treatment of anterior pelvic ring fractures. Between January 2012 and October 2013, 16 patients with anterior pelvic ring fractures were treated with MIPPO. There were 10 males and 6 females at the age of 20-63 years (mean, 41 years). The causes of injury were traffic accident in 9 cases and falling from height in 7 cases. The duration of injury to admission was 2 hours to 5 days (mean, 1 day). According to Tile classification, 8 cases were rated as type B2, 4 cases as type B3, 2 cases as type C1, and 2 cases as type C2. Of them, 2 cases had iliac wing fracture, and 4 cases had pelvic posterior ring fracture. The time from admission to operation was 3-12 days (mean, 6 days). The bleeding volume was 60-120 mL (mean, 70 mL). All wounds healed by first intention. No postoperative complication of deep venous thrombosis or long-term continuous pain occurred. All cases were followed up 5-27 months (mean, 11.5 months). No clinical manifestation of lateral femoral cutaneous nerve injury or spermatic cord injury was found, and cremasteric reflex existed in males. All cases obtained bony union, and the healing time was 12-16 weeks (mean, 13 weeks). During the follow-up period, no loss of fracture reduction and no internal fixation loosening or broken were observed. According to Matta radiological evaluation criterion, 16 cases had anatomical reduction, and 3 cases had satisfactory reduction; according to Majeed scoring system of pelvic fracture, the results were excellent in 12 cases and good in 4 cases. MIPPO for treatment of anterior pelvic ring fractures has the advantages of less intraoperative blood loss, few soft tissue complications, and low infection rate, and can get satisfactory short- term effectiveness.

  1. The impact of a national clinician-led audit initiative on care and mortality after hip fracture in England: an external evaluation using time trends in non-audit data.

    PubMed

    Neuburger, Jenny; Currie, Colin; Wakeman, Robert; Tsang, Carmen; Plant, Fay; De Stavola, Bianca; Cromwell, David A; van der Meulen, Jan

    2015-08-01

    Hip fracture is the most common serious injury of older people. The UK National Hip Fracture Database (NHFD) was launched in 2007 as a national collaborative, clinician-led audit initiative to improve the quality of hip fracture care, but has not yet been externally evaluated. We used routinely collected data on 471,590 older people (aged 60 years and older) admitted with a hip fracture to National Health Service (NHS) hospitals in England between 2003 and 2011. The main variables of interest were the use of early surgery (on day of admission, or day after) and mortality at 30 days from admission. We compared time trends in the periods 2003-2007 and 2007-2011 (before and after the launch of the NHFD), using Poisson regression models to adjust for demographic changes. The number of hospitals participating in the NHFD increased from 11 in 2007 to 175 in 2011. From 2007 to 2011, the rate of early surgery increased from 54.5% to 71.3%, whereas the rate had remained stable over the period 2003-2007. Thirty-day mortality fell from 10.9% to 8.5%, compared with a small reduction from 11.5% to 10.9% previously. The annual relative reduction in adjusted 30-day mortality was 1.8% per year in the period 2003-2007, compared with 7.6% per year over 2007-2011 (P<0.001 for the difference). The launch of a national clinician-led audit initiative was associated with substantial improvements in care and survival of older people with hip fracture in England.

  2. [Effect of 3D printing technology on pelvic fractures:a Meta-analysis].

    PubMed

    Zhang, Yu-Dong; Wu, Ren-Yuan; Xie, Ding-Ding; Zhang, Lei; He, Yi; Zhang, Hong

    2018-05-25

    To evaluate the effect of 3D printing technology applied in the surgical treatment of pelvic fractures through the published literatures by Meta-analysis. The PubMed database, EMCC database, CBM database, CNKI database, VIP database and Wanfang database were searched from the date of database foundation to August 2017 to collect the controlled clinical trials in wich 3D printing technology was applied in preoperative planning of pelvic fracture surgery. The retrieved literatures were screened according to predefined inclusion and exclusion criteria, and quality evaluation were performed. Then, the available data were extracted and analyzed with the RevMan5.3 software. Totally 9 controlled clinical trials including 638 cases were chosen. Among them, 279 cases were assigned to the 3D printing technology group and 359 cases to the conventional group. The Meta-analysis results showed that the operative time[SMD=-2.81, 95%CI(-3.76, -1.85)], intraoperative blood loss[SMD=-3.28, 95%CI(-4.72, -1.85)] and the rate of complication [OR=0.47, 95%CI(0.25, 0.87)] in the 3D printing technology were all lower than those in the conventional group;the excellent and good rate of pelvic fracture reduction[OR=2.09, 95%CI(1.32, 3.30)] and postoperative pelvic functional restoration [OR=1.94, 95%CI(1.15, 3.28) in the 3D printing technology were all superior to those in the conventional group. 3D printing technology applied in the surgical treatment of pelvic fractures has the advantage of shorter operative time, less intraoperative blood loss and lower rate of complication, and can improve the quality of pelvic fracture reduction and the recovery of postoperative pelvic function. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  3. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    PubMed

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  4. Baseline Serum Estradiol and Fracture Reduction During Treatment With Hormone Therapy: The Women’s Health Initiative Randomized Trial

    PubMed Central

    Cauley, Jane A.; LaCroix, Andrea Z.; Robbins, John A.; Larson, Joseph; Wallace, Robert; Wactawski-Wende, Jean; Chen, Zhao; Bauer, Douglas C.; Cummings, Steven R.; Jackson, Rebecca

    2009-01-01

    Purpose To test the hypothesis that the reduction in fractures with hormone therapy (HT) is greater in women with lower estradiol levels. Methods We conducted a nested case-control study within the Women’s Health Initiative HT Trials. The sample included 231 hip fracture case-control pairs and a random sample of 519 all fracture case-control pairs. Cases and controls were matched for age, ethnicity, randomization date, fracture history and hysterectomy status. Hormones were measured prior to randomization. Incident cases of fracture identified over an average follow-up of 6.53 years. Results There was no evidence that the effect of HT on fracture differed by baseline estradiol (E2) or sex hormone binding globulin (SHBG). Across all quartiles of E2 and SHBG, women randomized to HT had about a 50% lower risk of fracture including hip fracture, compared to placebo. Conclusion The effect of HT on fracture reduction is independent of estradiol and SHBG levels. PMID:19436934

  5. The value of arthroscopy in the treatment of complex ankle fractures - a protocol of a randomised controlled trial.

    PubMed

    Braunstein, Mareen; Baumbach, Sebastian F; Regauer, Markus; Böcker, Wolfgang; Polzer, Hans

    2016-05-12

    An anatomical reconstruction of the ankle congruity is the important prerequisite in the operative treatment of acute ankle fractures. Despite anatomic restoration patients regularly suffer from residual symptoms after these fractures. There is growing evidence, that a poor outcome is related to the concomitant traumatic intra-articular pathology. By supplementary ankle arthroscopy anatomic reduction can be confirmed and associated intra-articular injuries can be treated. Nevertheless, the vast majority of complex ankle fractures are managed by open reduction and internal fixation (ORIF) only. Up to now, the effectiveness of arthroscopically assisted fracture treatment (AORIF) has not been conclusively determined. Therefore, a prospective randomised study is needed to sufficiently evaluate the effect of AORIF compared to ORIF in complex ankle fractures. We perform a randomised controlled trial at Munich University Clinic enrolling patients (18-65 years) with an acute ankle fracture (AO 44 A2, A3, B2, B3, C1 - C3 according to AO classification system). Patients meeting the inclusion criteria are randomised to either intervention group (AORIF, n = 37) or comparison group (ORIF, n = 37). Exclusion criteria are fractures classified as AO type 44 A1 or B1, pilon or plafond-variant injury or open fractures. Primary outcome is the AOFAS Score (American Orthopaedic Foot and Ankle Society). Secondary outcome parameter are JSSF Score (Japanese Society of Surgery of the Foot), Olerud and Molander Score, Karlsson Score, Tegner Activity Scale, SF-12, radiographic analysis, arthroscopic findings of intra-articular lesions, functional assessments, time to return to work/sports and complications. This study protocol is accordant to the SPIRIT 2013 recommendation. Statistical analysis will be performed using SPSS 22.0 (IBM). The subjective and functional outcome of complex ankle fractures is regularly unsatisfying. As these injuries are very common it is essential to improve the postoperative results. Potentially, arthroscopically assisted fracture treatment can significantly improve the outcome by addressing the intra-articular pathologies. Given the absolute lack of studies comparing AORIF to ORIF in complex ankle fractures, this randomised controlled trail is urgently needed to evaluate the effectiveness of additional arthroscopy. ClinicalTrials.gov reference: NCT02449096 (Trial registration date: April 7th, 2015).

  6. Treatment of linear mandibular fractures using a single 2.0-mm AO locking reconstruction plate: is a second plate necessary?

    PubMed

    Scolozzi, Paolo; Martinez, Alvaro; Jaques, Bertrand

    2009-12-01

    To prospectively evaluate the use of a single Arbeitsgemeinschaft für Osteosynthesefragen (AO) 2.0-mm locking reconstruction plate for linear noncomminuted mandibular fractures without the use of a second plate. We analyzed the clinical and radiologic data of 45 patients with 74 fractures (21 single fractures, 22 double fractures, and 2 triple fractures). Fracture locations were the symphysis (n = 35, 47.3%), body (n = 15, 20.3%), and angle (n = 24, 32.4%). We recorded the mechanism of injury, time between admission to the hospital and surgery, gender and age, temporary maxillomandibular fixation and its duration, and the surgical approach. Postsurgical complications that were recorded as minor did not require surgical intervention, whereas major complications required further surgical intervention. All patients had satisfactory fracture reduction and a successful treatment outcome without major complications. Ten patients (22.2%) developed minor complications. The present study has demonstrated that treating linear noncomminuted mandibular fractures with a single AO 2.0-mm locking reconstruction plates is associated with no major complications and sound bone healing in all patients.

  7. 7-year follow-up after open reduction and internal screw fixation in Bennett fractures.

    PubMed

    Leclère, Franck Marie Patrick; Jenzer, Achat; Hüsler, Rolf; Kiermeir, David; Bignion, Dietmar; Unglaub, Frank; Vögelin, Esther

    2012-07-01

    Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation. Between June 1997 and December 2005, 24 patients with Bennett fractures were treated with open reduction and internal fixation with screws at our center. Radiological and functional assessments including range of motion of the thumb and pinch and grip strength were performed 4 months post-procedure and at the long-term follow-up, on average 83 months after surgery. Reduction of the Bennett fracture was maintained as it was at the time of the procedure in 96 % of the cases when fixation with two lag screws was performed. At the 4-month follow-up, mean pinch and grip strength reached 92 ± 3 and 89 ± 4 % of the contralateral side, respectively. Long-term follow-up demonstrated no correlation between the accuracy of the fracture reduction and the development of post-traumatic arthritis. Good clinical results could be observed, if successful reduction of the fracture was achieved and maintained. However, there was no correlation between the accuracy of the fracture reduction considering a gap and step <2 mm and the development of arthritis.

  8. Does fluoroscopy improve outcomes in paediatric forearm fracture reduction?

    PubMed

    Menachem, S; Sharfman, Z T; Perets, I; Arami, A; Eyal, G; Drexler, M; Chechik, O

    2016-06-01

    To compare the radiographic results of paediatric forearm fracture reduced with and without fluoroscopic enhancement to investigate whether fractures reduced under fluoroscopic guidance would have smaller residual deformities and lower rates of re-reduction and surgery. A retrospective cohort analysis was conducted comparing paediatric patients with acute forearm fracture in two trauma centres. Demographics and radiographic data from paediatric forearm fractures treated in Trauma Centre A with the aid of a C-arm fluoroscopy were compared to those treated without fluoroscopy in Trauma Centre B. Re-reduction, late displacement, post-reduction deformity, and need for surgical intervention were compared between the two groups. The cohort included 229 children (175 boys and 54 girls, mean age 9.41±3.2 years, range 1-16 years) with unilateral forearm fractures (83 manipulated with fluoroscopy and 146 without). Thirty-four (15%) children underwent re-reduction procedures in the emergency department. Fifty-three (23%) children had secondary displacement in the cast, of which 18 were operated on, 20 were re-manipulated, and the remaining 15 were kept in the cast with an acceptable deformity. Twenty-nine additional children underwent operation for reasons other than secondary displacement. There were no significant differences in re-reduction and surgery rates or in post-reduction deformities between the two groups. The use of fluoroscopy during reduction of forearm fractures in the paediatric population apparently does not have a significant effect on patient outcomes. Reductions performed without fluoroscopy were comparably accurate in correcting deformities in both coronal and sagittal planes. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Supination and Pronation Strength Deficits Persist at 2-4 Years after Treatment of Distal Radius Fractures.

    PubMed

    Ploegmakers, Joris; The, Bertram; Wang, Allan; Brutty, Mike; Ackland, Tim

    2015-10-01

    Forearm rotation is a key function in the upper extremity. Following distal radius fracture, residual disability may occur in tasks requiring forearm rotation. The objectives of this study are to define pronation and supination strength profiles tested through the range of forearm rotation in normal individuals, and to evaluate the rotational strength profiles and rotational strength deficits across the testing range in a cohort of patients treated for distal radius fracture associated with an ulnar styloid base fracture. In a normative cohort of 29 subjects the supination strength profile showed an increasing linear relationship from supination to pronation. Twelve subjects were evaluated 2-4 years after anatomical open reduction and volar plate fixation of a distal radius fracture. The injured wrist was consistently weaker (corrected for hand dominance) in both supination and pronation strength in all testing positions, with the greatest loss in 60 degrees supination. Mean supination strength loss across all testing positions was significantly correlated with worse PRWE scores, highlighting the importance of supination in wrist function.

  10. Identification of the Cause of the Stem Neck Fracture in the Hip Joint Endoprosthesis

    NASA Astrophysics Data System (ADS)

    Ryniewicz, A. M.; Bojko, Ł.; Ryniewicz, A.; Pałka, P.; Ryniewicz, W.

    2018-02-01

    Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides) that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.

  11. Hip arthroscopy using the lateral approach.

    PubMed

    Glick, J M

    1988-01-01

    The benefits of hip arthroscopy are apparent. It produces little postoperative morbidity and can be performed on an outpatient basis. The prompt recovery from the operation is also beneficial, particularly for elderly patients. Distraction of the hip by traction on a fracture table is necessary. Suggested indications for this procedure include synovectomy and synovial biopsy; removal of loose bodies; removal of debris after a closed reduction of a fracture-dislocation; evaluation and treatment of osteochondritis dissecans; evaluation for arthroplasty; and unresolved hip pain. Whether the lateral approach is useful in the following situations is yet to be explored: (1) Evaluation of pediatric conditions such as Legg-Perthes disease and congenital dislocated hip; (2) treatment of localized infection; (3) removal of entrapped methylmethacrylate in total hip replacement; and (4) reducing and fixating an acetabular fracture (M. Brennan, oral communication, April 6, 1987). Arthroscopy of the hip joint by the lateral approach is a valuable addition to the evaluation and treatment of hip disorders.

  12. Manipulation of nasal fractures with local anaesthetic: a 'how to do it' with online video tutorial.

    PubMed

    Repanos, Costa; Anderson, Daniel; Earnshaw, James; Mitchell, David; Coman, William

    2010-06-01

    Nasal fractures are the most common facial fractures and displaced fractures may cause considerable cosmetic concern. Traditionally, displaced nasal fractures have been manipulated under general anaesthesia (GA) performed within 2 weeks of the injury. Despite evidence for the benefit of local anaesthesia (LA), nasal fractures are still most commonly reduced under GA. We have presented a method of reduction of simple nasal fractures under LA in an outpatient setting. This has the advantage of being painless, simple to attempt and cost-effective. If reduction is inadequate then a general anaesthetic reduction is still possible. A recent comprehensive systematic review of all the available evidence did not show any significant difference (in terms of cosmesis, pain or nasal obstruction) between using LA and GA methods and highlighted the evidence base to support LA. We describe our method of assessment and treatment of displaced nasal fractures and provide an online tutorial (http://sciencestage.com/v/22194/local-anaesthetic-nasal-fracture-reduction.html). It is important to keep in mind that any concerns should be referred to an otolaryngology specialist for further management and that practitioners attempting this technique should first receive training from an otolaryngologist.

  13. Minimally invasive treatment for pubic ramus fractures combined with a sacroiliac joint complex injury.

    PubMed

    Yu, Xiaowei; Tang, Mingjie; Zhou, Zubin; Peng, Xiaochun; Wu, Tianyi; Sun, Yuqiang

    2013-08-01

    Fractures of the pubic rami due to low energy trauma are common in the elderly, with an incidence of 26 per 100,000 people per year in those aged more than 60 years. The purpose of this study was to evaluate the clinical application of this minimally invasive technique in patients with pubic ramus fractures combined with a sacroiliac joint complex injury, including its feasibility, merits, and limitations. Fifteen patients with pubic ramus fractures combined with sacroiliac joint injury were treated with the minimally invasive technique from June 2008 until April 2012. The quality of fracture reduction was evaluated according to the Matta standard. Fourteen cases were excellent (93.3 %), and one case was good (6.7 %). The fracture lines were healed 12 weeks after the surgery. The 15 patients had follow-up visits between four to 50 months (mean, 22.47 months). All patients returned to their pre-injury jobs and lifestyles. One patient suffered a deep vein thrombosis during the peri-operative period. A filter was placed in the patient before the surgery and was removed six weeks later. There was no thrombus found at the follow-up visits of this patient. The minimally invasive technique in patients with pubic ramus fractures combined with a sacroiliac joint complex injury provided satisfactory efficacy.

  14. Proximal Humerus Fractures: Evaluation and Management in the Elderly Patient

    PubMed Central

    Grawe, Brian

    2018-01-01

    Introduction: Proximal humerus fractures are common in the elderly. The evaluation and management of these injuries is often controversial. The purpose of this study is to review recent evidence and provide updated recommendations for treating proximal humerus fractures in the elderly. Methods: A literature review of peer-reviewed publications related to the evaluation and management of proximal humerus fractures in the elderly was performed. There was a focus on randomized controlled trials and systematic reviews published within the last 5 years. Results: The incidence of proximal humerus fractures is increasing. It is a common osteoporotic fracture. Bone density is a predictor of reduction quality and can be readily assessed with anteroposterior views of the shoulder. Social independence is a predictor of outcome, whereas age is not. Many fractures are minimally displaced and respond acceptably to nonoperative management. Displaced and severe fractures are most frequently treated operatively with intramedullary nails, locking plates, percutaneous techniques, or arthroplasty. Discussion: Evidence from randomized controlled trials and systematic reviews is insufficient to recommend a treatment; however, most techniques have acceptable or good outcomes. Evaluation should include an assessment of the patient’s bone quality, social independence, and surgical risk factors. With internal fixation, special attention should be paid to medial comminution, varus angulation, and restoration of the calcar. With arthroplasty, attention should be paid to anatomic restoration of the tuberosities and proper placement of the prosthesis. Conclusion: A majority of minimally displaced fractures can be treated conservatively with early physical therapy. Treatment for displaced fractures should consider the patient’s level of independence, bone quality, and surgical risk factors. Fixation with percutaneous techniques, intramedullary nails, locking plates, and arthroplasty are all acceptable treatment options. There is no clear evidence-based treatment of choice, and the surgeon should consider their comfort level with various procedures during the decision-making process. PMID:29399372

  15. [A study of proximal humerus fractures using close reduction and percutaneous minimally invasive fixation].

    PubMed

    Liu, Yin-wen; Kuang, Yong; Gu, Xin-feng; Zheng, Yu-xin; Li, Zhi-qiang; Wei, Xiao-en; Lu, Wei-da; Zhan, Hong-sheng; Shi, Yin-yu

    2011-11-01

    To investigate the clinical effects of close reduction and percutaneous minimally invasive fixation in the treatment of proximal humerus fractures. From April 2008 to March 2010, 28 patients with proximal humerus fracture were treated with close reduction and percutaneous minimally invasive fixation. There were 21 males and 7 females, ranging in age from 22 to 78 years,with an average of 42.6 years. The mean time from suffering injuries to the operation was 1.7 d. Nineteen cases caused by falling down, 9 cases by traffic accident. The main clinical manifestation was swelling, pain and limited mobility of shoulders. According to Neer classification, two part fractures were in 17 cases and three part fractures in 11 cases. The locking proximal humerus plate was used to minimally fixation through deltoid muscle under acromion. The operating time,volume of blood loss, the length of incision and Constant-Murley assessment were applied to evaluate the therapeutic effects. The mean operating time was 40 min, the mean blood loss was 110 ml, and the mean length of incision was about 5.6 cm. The postoperative X-ray showed excellent reduction and the plate and screws were successfully place. Twenty-eight patients were followed up for 6 to 24 months (averaged 14.2 months). The healing time ranged from 6 to 8 weeks and all incision was primarily healed. There were no cases with necrosis head humerus, 24 cases without omalgia, and 4 cases with o-malgia occasionally. All the patients can complete the daily life. The mean score of Constant-Murley assessment was 91.0 +/- 5.8, 24 cases got an excellent result, 3 good and 1 fair. Close reduction and percutaneous minimally invasive fixation, not only can reduce surgical invasive, but also guarantee the early function activities. It has the advantages of less invasive, fixed well and less damage of blood circulation.

  16. Paediatric forearm fractures: functional outcome of conservative treatment.

    PubMed

    Tarmuzi, Nazari Ahmad; Abdullah, Shalimar; Osman, Zulkiflee; Das, Srijit

    2009-01-01

    Forearm fractures are common in the paediatric age group. Closed reduction and casting are the primary means of treatment in over 90% of these fractures. Resultant deformities are usually a product of indirect trauma involving angular loading combined with rotational deformity and fragment displacement. Retrospectively, 48 patients aged between 4 to 12 years with forearm fractures, were treated conservatively with closed reduction and a cast during a 2-year period. Functional outcomes were measured in terms of pronation and supination. All fractures united before the final visit. Most forearm bone fractures were complete fractures at the mid shaft. Eighty-six percent of the patients had excellent functional outcomes and none had poor outcomes. There were significantly reduced angles of deformities before and after treatment (p < 0.05). Radiographically, in the frontal plane, 57.1% of radius and 73.9% of ulnar fractures achieved perfect reduction (i.e. a degree of deformity of less than 5 degrees). However, in the lateral plane, there were fewer perfect reductions for the radius and ulna, at 14.6% and 54.3%, respectively. All except for one patient were satisfied with the outcomes. The level of fracture did not influence the outcomes. Conservative treatment is still an acceptable form of treatment especially for stable forearm fractures in children achieving excellent outcomes (Tab. 1, Fig. 7, Ref. 20).

  17. A novel closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation for mallet fractures.

    PubMed

    Shimura, Haruhiko; Wakabayashi, Yoshiaki; Nimura, Akimoto

    2014-03-01

    Some patients with mallet fractures who undergo extension block pinning complain of exposed wires, which delay their return to sports and causes inconvenience while performing tasks that require the use of hands during the early postoperative period. The purpose of this retrospective study was to present and evaluate a novel surgical procedure for mallet fractures. We treated 20 patients (14 males and six females; mean age, 38.4 years; range 17-68 years) with displaced mallet fractures involving >30 % of the articular surface using the closed reduction and microscrew fixation between January 2009 and January 2012. The distal interphalangeal joint (DIP) joint was immobilized with a splint for 1-3 weeks on an individual case basis. According to Wehbe and Schneider's classification, there were 12 type IB, six type IIB, and two type IA fractures. The mean follow-up duration was 12.6 months (range 6-31 months). Bone union was achieved in all patients within a mean period of 6.8 weeks, with no incidence of infection, skin necrosis, permanent nail deformity, or secondary osteoarthritis. Only two complications-temporary nail ridging in one patient and a dorsal bump caused by the screw in one patient-were observed. Minimum postoperative displacement was observed in one patient, for whom immobilization with a splint was continued for 4 weeks. Articular incongruity was <1.0 mm in four patients and 1.0-2.0 mm in two patients. Mean DIP joint extension loss was 6.5° and mean flexion was 67.8°. The surgical outcomes were excellent in seven patients, good in nine, and fair in four according to Crawford's evaluation criteria. Our novel surgical procedure combining closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation produces good clinical results with relatively few complications.

  18. Surgical Treatment of the Atrophic Mandibular Fractures by Locked Plates Systems: Our Experience and a Literature Review

    PubMed Central

    Novelli, Giorgio; Sconza, Cristiano; Ardito, Emanuela; Bozzetti, Alberto

    2012-01-01

    The management of atrophic mandibular fractures in edentulous patients represents an insidious issue for the maxillofacial surgeon due to the biological and biomechanical conditions that are unfavorable for fracture fixation and bone healing. The purpose of this study was to evaluate the results of the treatment of atrophic mandibular fractures and to compare the outcomes of different plating systems used for stabilization. We selected a study group of 16 patients with fractures of completely edentulous atrophic mandibles who were treated in our department between 2004 and 2010. All patients were surgically treated by open reduction and internal rigid fixation using 2.0-mm large-profile locking and 2.4-mm locking bone plates. All patients achieved a complete fracture healing and fast functional recovery of mandibular movements without intraoperative or postoperative surgical complications. The results of our study demonstrated the efficacy of this type of treatment in association with a low postoperative complication rate, a reduction in the recovery time, and the possibility to have an immediately functional rehabilitation. There were very similar results using each of the two bone plating methods considered: no case had hardware failure or nonunion of the fracture. The 2.0-mm large locking plate is thinner, exposes through the soft tissues less frequently, and is much easier to shape and adapt to the mandibular anatomy. However, the 2.4-mm locking plate system still represents the reference hardware in the condition of severe bone atrophy. PMID:23730420

  19. Management of acetabular fractures with modified posterior approach to spare external hip rotators.

    PubMed

    Sarlak, Ahmet Y; Selek, Ozgur; Inanir, Murat; Musaoglu, Resul; Baran, Tuncay

    2014-04-01

    In the present study the quality of reduction and incidence of complications in hip external rotator sparing modified posterior approach was assessed in both simple and complex acetabular fractures. This retrospective study includes 37 patients (38 hips) with a mean age of 42.1 years (range 21-60), that had been treated for displaced acetabular fractures from June 2007 through May 2011. They were reviewed at a mean of 3 years (20-67 months). The fractures were classified according to the Letournel-Judet classification. Anatomic reduction and stable fixation of the fracture with less than 2mm residual displacement was achieved in 28 of 38 hips. At the final follow up the patients were evaluated clinically according to Merle d'Aubigne and Postel scoring system which had been modified by Matta and radiologically based on the criteria described by Matta. The clinical results were excellent in 20, good in 8, fair in 8, and poor 2 hips. Complications included two superficial local wound infection and 10 heterotopic ossification with 7 of the cases having grade I heterotopic ossification. Avascular necrosis of the femoral head was not seen in any of the 38 hips. One patient with preoperative sciatic nerve palsy had complete recovery of neurologic function. There were no cases of deep vein thrombosis or pulmonary embolism. The functional outcome was satisfactory in most of the cases and comparable with other larger series. Using the limited part of Henry's sciatic nerve exposure skin incision - working in the plane between gluteus maximus and the tensor fascia lata as in the classical Gibson approach and two portal external rotator hip sparing approach resulted in good fracture reduction without approach related complications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Advantages of external hybrid fixators for treating Schatzker V-VI tibial plateau fractures: A retrospective study of 40 cases.

    PubMed

    Gross, J-B; Gavanier, B; Belleville, R; Coudane, H; Mainard, D

    2017-10-01

    Proximal tibia fractures make up 1% of all fractures in adults. The fractures classified as Schatzker V and VI fractures can compromise knee structure and function. They are challenging to treat and often have complications. While plate fixation is the gold standard, the resulting infection rate has led us to favor external hybrid fixation. The aims of this study were to assess the radiographic and functional outcomes along with the complication rate when using this method and to compare them to historical plate fixation data. This was a retrospective study of 40 patients. The complications, quality of reduction, IKS, Lysholm and Rasmussen functional scores at the latest follow-up and factors affecting the functional outcome were evaluated. These parameters were compared to published results from plate fixation studies. The deep infection rate was 2.5%. The union rate was 80%. Satisfactory reduction was obtained in 70% of cases; however, 52% of patients had malunion. The mean IKS score was 73.74, the mean Rasmussen score was 22.85 and the mean Lysholm score was 75.53. Age, reduction at latest follow-up, mechanical axis and anteroposterior laxity had a significant effect on the functional outcome. Despite the malunion rate being higher than other studies, the functional outcomes were nearly identical based on the variables measured. There are several advantages associated with using a hybrid external fixator: shorter operative time, less bleeding, shorter hospital stays and lower infection rate. Hybrid external fixation is a reliable fracture fixation method that leads to satisfactory functional outcomes, while reducing the infection rate and allowing arthroplasty to be performed in the future if needed. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study.

    PubMed

    Sobhan, Mohammad R; Abrisham, Seyed Mohammad J; Vakili, Mahmood; Shirdel, Saeed

    2016-10-01

    Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient's quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations. Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT) scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed's score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described. The injury was unilateral in 11 (78.5%) patients and bilateral in 3 (21.5%). Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4%) and 1 (7.1%) cases, respectively. In this study most patients (85%) return to work postoperatively. According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.

  2. Oral motor and electromyographic characterization of adults with facial fractures: a comparison between different fracture severities.

    PubMed

    da Silva, Amanda Pagliotto; Sassi, Fernanda Chiarion; Bastos, Endrigo; Alonso, Nivaldo; de Andrade, Claudia Regina Furquim

    2017-05-01

    To characterize the oral motor system of adults with facial injuries and to compare the oral motor performance/function between two different groups. An observational, descriptive, cross-sectional study was conducted in 38 patients presenting with facial trauma who were assigned to the Division of Orofacial Myology of a Brazilian School Hospital. Patients were divided into two groups: Group 1 (G1) consisted of 19 patients who were submitted to open reduction of at least one facial fracture, and Group 2 (G2) consisted of 19 individuals who were submitted to closed fracture reduction with maxillomandibular fixation. For comparison purposes, a group of 19 healthy volunteers was recruited. All participants underwent a clinical assessment that included an oral motor evaluation, assessment of the mandibular range of motions, and electromyographic assessment of the masticatory muscles. Clinical assessment of the oral motor organs indicated that G1 and G2 presented deficits related to the posture, position, and mobility of the oral motor organs. Patients also presented limited mandibular ranges of movement. Deficits were greater for individuals in G1, especially for maximal incisor opening. Additionally, patients in G1 and G2 presented a similar electromyographic profile of the masticatory muscles (i.e., patients with facial fractures presented lower overall muscle activity and significant asymmetrical activity of the masseter muscle during maximum voluntary teeth clenching). Patients in G1 and G2 presented similar functional deficits after fracture treatment. The severity of facial fractures did not influence muscle function/performance 4 months after the correction of fractures.

  3. Oral motor and electromyographic characterization of adults with facial fractures: a comparison between different fracture severities

    PubMed Central

    da Silva, Amanda Pagliotto; Sassi, Fernanda Chiarion; Bastos, Endrigo; Alonso, Nivaldo; de Andrade, Claudia Regina Furquim

    2017-01-01

    OBJECTIVES: To characterize the oral motor system of adults with facial injuries and to compare the oral motor performance/function between two different groups. METHODS: An observational, descriptive, cross-sectional study was conducted in 38 patients presenting with facial trauma who were assigned to the Division of Orofacial Myology of a Brazilian School Hospital. Patients were divided into two groups: Group 1 (G1) consisted of 19 patients who were submitted to open reduction of at least one facial fracture, and Group 2 (G2) consisted of 19 individuals who were submitted to closed fracture reduction with maxillomandibular fixation. For comparison purposes, a group of 19 healthy volunteers was recruited. All participants underwent a clinical assessment that included an oral motor evaluation, assessment of the mandibular range of motions, and electromyographic assessment of the masticatory muscles. RESULTS: Clinical assessment of the oral motor organs indicated that G1 and G2 presented deficits related to the posture, position, and mobility of the oral motor organs. Patients also presented limited mandibular ranges of movement. Deficits were greater for individuals in G1, especially for maximal incisor opening. Additionally, patients in G1 and G2 presented a similar electromyographic profile of the masticatory muscles (i.e., patients with facial fractures presented lower overall muscle activity and significant asymmetrical activity of the masseter muscle during maximum voluntary teeth clenching). CONCLUSION: Patients in G1 and G2 presented similar functional deficits after fracture treatment. The severity of facial fractures did not influence muscle function/performance 4 months after the correction of fractures. PMID:28591339

  4. Clavicle fracture with intrathoracic displacement.

    PubMed

    Lohse, Grant R; Lee, Donald H

    2013-08-01

    Clavicle fractures are common, and most are isolated injuries. Injury to the nearby subclavian vessels and brachial plexus have classically been described as potential complications of clavicle fractures. However, in the setting of a substantially displaced clavicle fracture, concomitant thoracic trauma is relatively frequent. Injury to the thorax can be difficult to identify on physical examination, and advanced imaging modalities may be required for diagnosis. The evaluation, workup, and management of a patient with intrathoracic displacement of a clavicle fracture are described. Despite the significant fracture displacement and associated pneumothorax, the injury severity was not clinically obvious. Imaging, including a screening chest radiograph and subsequent axial computed tomography, played an important role in diagnosis and management. The patient underwent successful open reduction and plate fixation. A thoracostomy tube was not required at any point during the hospitalization. The patient recovered uneventfully and returned to full work duty by 3 months postoperatively. Including the current report, only 3 cases of intrathoracic displacement of the clavicle have been published in the English literature. All involved fractures of the middle third of the clavicle. The severity of displacement was not obvious in any patient, and diagnosis was dependent on additional imaging. Given the frequency of associated chest trauma and limitations of physical examination, chest radiography should be considered in the evaluation of patients with substantially displaced clavicle fractures. Copyright 2013, SLACK Incorporated.

  5. Kirschner wire fixation of Salter-Harris type IV fracture of the lateral aspect of the humeral condyle in growing dogs. A retrospective study of 35 fractures.

    PubMed

    Cinti, Filippo; Pisani, Guido; Vezzoni, Luca; Peirone, Bruno; Vezzoni, Aldo

    2017-01-16

    To evaluate the use of Kirschner wires for treatment of fractures of the lateral aspect of the humeral condyle in growing dogs. Retrospective analysis of 35 elbow fractures (33 dogs) of the lateral aspect of the humeral condyle treated by insertion of multiple transcondylar and one anti-rotational Kirschner wires. Radiographic and clinical re-evaluations were carried out immediately after surgery, at four weeks and, when required, at eight weeks postoperatively. Long-term follow-up was planned after a minimum of six months. The relationship between different implant configurations and clinical outcome was analysed statistically. Complete functional recovery was seen in 31 elbows (30 dogs), three elbows (2 dogs) had reduction in the range of motion, and one elbow (1 dog) had persistent grade 1 lameness two months postoperatively. Major complications occurred in eight elbows (8 dogs) and all were resolved by implant removal. Implant configuration did not affect outcome. Long-term evaluation in 12 cases with a mean follow-up of four years showed absence of lameness, normal function and no or mild radiographic evidence of osteoarthritis in 11 cases. Fracture of the lateral aspect of the humeral condyle in growing dogs can be successfully treated by multiple transcondylar convergent or parallel Kirschner wires, resulting in adequate fracture healing.

  6. Percutaneous or Open Reduction of Closed Tibial Shaft Fractures During Intramedullary Nailing Does Not Increase Wound Complications, Infection or Nonunion Rates.

    PubMed

    Auston, Darryl A; Meiss, Jordan; Serrano, Rafael; Sellers, Thomas; Carlson, Gregory; Hoggard, Timothy; Beebe, Michael; Quade, Jonathan; Watson, David; Simpson, Robert Bruce; Kistler, Brian; Shah, Anjan; Sanders, Roy; Mir, Hassan R

    2017-04-01

    To compare the incidence of complications (wound, infection, and nonunion) among those patients treated with closed, percutaneous, and open intramedullary nailing for closed tibial shaft fractures. Retrospective review. Multiple trauma centers. Skeletally mature patients with closed tibia fractures amenable to treatment with an intramedullary device. Intramedullary fixation with closed, percutaneous, or open reduction. Superficial wound complication, deep infection, nonunion. A total of 317 tibial shaft fractures in 315 patients were included in the study. Two-hundred fractures in 198 patients were treated with closed reduction, 61 fractures in 61 patients were treated with percutaneous reduction, and 56 fractures in 56 patients were treated with formal open reduction. The superficial wound complication rate was 1% (2/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 3.6% (2/56) for the open group with no statistical difference between the groups (P = 0.179). The deep infection rate was 2% (4/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 7.1% (4/56) for the open group with no significant difference between the groups (P = 0.133). Nonunion rate was 5.0% (10/200) for the closed group, 4.9% (3/61) for the percutaneous group, and 7.1% (4/56) for the open group, with no statistical difference between the groups (P = 0.492). This is the largest reported series of closed tibial shaft fractures nailed with percutaneous and open reduction. Percutaneous or open reduction did not result in increased wound complications, infection, or nonunion rates. Carefully performed percutaneous or open approaches can be safely used in obtaining reduction of difficult tibial shaft fractures treated with intramedullary devices. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  7. Clinical Comparison of Extensile Lateral Approach and Sinus Tarsi Approach Combined with Medial Distraction Technique for Intra-Articular Calcaneal Fractures.

    PubMed

    Zhou, Hai-Chao; Yu, Tao; Ren, Hao-Yang; Li, Bing; Chen, Kai; Zhao, You-Guang; Yang, Yun-Feng

    2017-02-01

    To study and compare the clinical outcomes of open reduction and internal fixation via extensile L-shape incision and limited open reduction via the sinus tarsi approach using the medial distraction technique for intra-articular calcaneal fractures. We performed a retrospective review of 65 intra-articular calcaneal fractures treated operatively between March 2012 and February 2015. Patients were divided into two groups: 28 were in the sinus tarsi approach group and 37 were in the extensile lateral approach group. All patients were asked to return for a research visit that included radiography and clinical evaluation. The postoperative function was evaluated using the ankle and hindfoot score of the American Orthopaedic Foot and Ankle Society (AOFAS) and the visual analogue scale (VAS). No significant difference was found in demographics between the two groups. The corrected value of the calcaneal varus angle between the two groups is statistically significant (P < 0.05). The overall wound complication rate was 3.6% in the minimally invasive group versus 13.5% in the extensile group. Four patients in the extensile lateral approach group had developed hindfoot varus deformity at last follow-up. At the last follow-up, the average AOFAS ankle and the hindfoot score of the minimal group was 88.4 ± 6.6, and the VAS score was 1.9 ± 0.7, while that of the extensile lateral approach group was 83.2 ± 5.6 and 2.3 ± 1.0, respectively. Limited open reduction via the sinus tarsi approach for intra-articular calcaneal fractures could reduce the incidence of wound complications effectively, and the medial distraction technique is helpful for correcting the calcaneus varus deformity. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  8. EVALUATION OF THE MORTALITY RATE ONE YEAR AFTER HIP FRACTURE AND FACTORS RELATING TO DIMINISHED SURVIVAL AMONG ELDERLY PEOPLE

    PubMed Central

    Ricci, Guilherme; Longaray, Maurício Portal; Gonçalves, Ramiro Zilles; Neto, Ary da Silva Ungaretti; Manente, Marislei; Barbosa, Luíza Barbosa Horta

    2015-01-01

    Objective: To evaluate the mortality rate after one year and correlated preoperative factors, among patients with hip fractures. Methods: We prospectively studied 202 out of a total of 376 patients with a diagnosis of hip fracture who were admitted to the Hospital Cristo Redentor, between October 2007 and March 2009. The database with the epidemiological analysis was set up during their hospitalization, and follow–up data were obtained preferentially by phone. Results: The overall mortality rate after one year of follow-up was 28.7% or 58 deaths, among which 11 (5.45%) occurred during hospitalization. Fractures were more prevalent among women (71.3%) and rare among blacks (5%). Among the comorbidities, dementia and depression showed a statistically significant reduction in survival (p = 0.018 and 0.007, respectively). Conclusion: The mortality rate after one year of follow-up was 28.7%. Dementia and depression increased this rate. PMID:27042638

  9. Zoledronic Acid for the Treatment and Prevention of Primary and Secondary Osteoporosis

    PubMed Central

    Rizzoli, René

    2010-01-01

    There is increasing interest in therapies that can be administered less frequently and/or avoid gastrointestinal irritation. The efficacy of once-yearly zoledronic acid (5 mg) in the treatment and prevention of osteoporosis has been evaluated in different patient populations. In the 3-year HORIZON-Pivotal Fracture Trial in postmenopausal women with osteoporosis, zoledronic acid reduced the risk of vertebral and hip fracture by 70% and 41%, respectively, versus placebo. The efficacy of zoledronic acid in preventing subsequent fracture in patients with a hip fracture was evaluated in the HORIZON-Recurrent Fracture Trial. New vertebral and nonvertebral fractures were significantly reduced by treatment initiated within 90 days of incident hip fracture, without evidence of delayed fracture healing. Data from a 1-year study show that a single zoledronic acid 5-mg infusion is superior to oral risedronate 5 mg/day for treatment and prevention of glucocorticoid-induced osteoporosis. Increases in bone mineral density and decreases in bone turnover markers were significantly greater with zoledronic acid than with risedronate. Two different treatment regimens of zoledronic acid were found to be more effective than placebo for prevention of bone loss in postmenopausal women and reducing markers of bone turnover after 2 years. In conclusion, zoledronic acid 5 mg once-yearly infusion has demonstrated marked efficacy in the treatment and prevention of primary and secondary osteoporosis, with a combination of fracture risk reduction and prevention of bone loss at key sites. It is the only agent shown to reduce the incidence of fracture and mortality in patients with a previous low-trauma hip fracture. PMID:22870433

  10. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    PubMed

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P <0.05). There were no statistically significant differences observed between two approaches with respect to nounion, re-operation, complex regional pain syndrome, carpal tunnel syndrome, neurapraxia, tendonitis, painful hardware, scar( P >0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  11. Probabilistic Risk Assessment for Astronaut Post Flight Bone Fracture

    NASA Technical Reports Server (NTRS)

    Lewandowski, Beth; Myers, Jerry; Licata, Angelo

    2015-01-01

    Introduction: Space flight potentially reduces the loading that bone can resist before fracture. This reduction in bone integrity may result from a combination of factors, the most common reported as reduction in astronaut BMD. Although evaluating the condition of bones continues to be a critical aspect of understanding space flight fracture risk, defining the loading regime, whether on earth, in microgravity, or in reduced gravity on a planetary surface, remains a significant component of estimating the fracture risks to astronauts. This presentation summarizes the concepts, development, and application of NASA's Bone Fracture Risk Module (BFxRM) to understanding pre-, post, and in mission astronaut bone fracture risk. The overview includes an assessment of contributing factors utilized in the BFxRM and illustrates how new information, such as biomechanics of space suit design or better understanding of post flight activities may influence astronaut fracture risk. Opportunities for the bone mineral research community to contribute to future model development are also discussed. Methods: To investigate the conditions in which spaceflight induced changes to bone plays a critical role in post-flight fracture probability, we implement a modified version of the NASA Bone Fracture Risk Model (BFxRM). Modifications included incorporation of variations in physiological characteristics, post-flight recovery rate, and variations in lateral fall conditions within the probabilistic simulation parameter space. The modeled fracture probability estimates for different loading scenarios at preflight and at 0 and 365 days post-flight time periods are compared. Results: For simple lateral side falls, mean post-flight fracture probability is elevated over mean preflight fracture probability due to spaceflight induced BMD loss and is not fully recovered at 365 days post-flight. In the case of more energetic falls, such as from elevated heights or with the addition of lateral movement, the contribution of space flight quality changes is much less clear, indicating more granular assessments, such as Finite Element modeling, may be needed to further assess the risks in these scenarios.

  12. The Effect of Three or Six Years of Denosumab Exposure in Women With Postmenopausal Osteoporosis: Results From the FREEDOM Extension

    PubMed Central

    Chapurlat, Roland; Brandi, Maria-Luisa; Brown, Jacques P.; Czerwiński, Edward; Krieg, Marc-Antoine; Mellström, Dan; Radominski, Sebastião C.; Reginster, Jean-Yves; Resch, Heinrich; Ivorra, Jose A. Román; Roux, Christian; Vittinghoff, Eric; Daizadeh, Nadia S.; Wang, Andrea; Bradley, Michelle N.; Franchimont, Nathalie; Geller, Michelle L.; Wagman, Rachel B.; Cummings, Steven R.; Papapoulos, Socrates

    2013-01-01

    Context: The Fracture Reduction Evaluation of Denosumab in Osteoporosis Every 6 Months (FREEDOM) extension is evaluating the long-term efficacy and safety of denosumab for up to 10 years. Objective: The objective of the study was to report results from the first 3 years of the extension, representing up to 6 years of denosumab exposure. Design, Setting, and Participants: This was a multicenter, international, open-label study of 4550 women. Intervention: Women from the FREEDOM denosumab group received 3 more years of denosumab for a total of 6 years (long-term) and women from the FREEDOM placebo group received 3 years of denosumab (crossover). Main Outcome Measures: Bone turnover markers (BTMs), bone mineral density (BMD), fracture, and safety data are reported. Results: Reductions in BTMs were maintained (long-term) or achieved rapidly (crossover) after denosumab administration. In the long-term group, BMD further increased for cumulative 6-year gains of 15.2% (lumbar spine) and 7.5% (total hip). During the first 3 years of denosumab treatment, the crossover group had significant gains in lumbar spine (9.4%) and total hip (4.8%) BMD, similar to the long-term group during the 3-year FREEDOM trial. In the long-term group, fracture incidences remained low and below the rates projected for a virtual placebo cohort. In the crossover group, 3-year incidences of new vertebral and nonvertebral fractures were similar to those of the FREEDOM denosumab group. Incidence rates of adverse events did not increase over time. Six participants had events of osteonecrosis of the jaw confirmed by adjudication. One participant had a fracture adjudicated as consistent with atypical femoral fracture. Conclusion: Denosumab treatment for 6 years remained well tolerated, maintained reduced bone turnover, and continued to increase BMD. Fracture incidence remained low. PMID:23979955

  13. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures.

    PubMed

    Gali, Rajasekhar; Devireddy, Sathya Kumar; Venkata, Kishore Kumar Rayadurgam; Kanubaddy, Sridhar Reddy; Nemaly, Chaithanyaa; Dasari, Mallikarjuna

    2016-01-01

    Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP) approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a) the ease of access for retrieval, reimplantation and fixation of the proximal segment; b) the postoperative approach related complications; c) the adequacy of anatomical reduction and stability of fixation; d) the occlusal changes; and the e) TMJ function and radiological changes. Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch) palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby permitting perpendicular placement of screws with minimal risk of damage to the facial nerve.

  14. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures

    PubMed Central

    Gali, Rajasekhar; Devireddy, Sathya Kumar; Venkata, Kishore Kumar Rayadurgam; Kanubaddy, Sridhar Reddy; Nemaly, Chaithanyaa; Dasari, Mallikarjuna

    2016-01-01

    Introduction: Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. Purpose: This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP) approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. Patients and Methods: This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a) the ease of access for retrieval, reimplantation and fixation of the proximal segment; b) the postoperative approach related complications; c) the adequacy of anatomical reduction and stability of fixation; d) the occlusal changes; and the e) TMJ function and radiological changes. Results: Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch) palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. Conclusion: The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby permitting perpendicular placement of screws with minimal risk of damage to the facial nerve. PMID:27274123

  15. The role of organic proteins on the crack growth resistance of human enamel.

    PubMed

    Yahyazadehfar, Mobin; Arola, Dwayne

    2015-06-01

    With only 1% protein by weight, tooth enamel is the most highly mineralized tissue in mammals. The focus of this study was to evaluate contributions of the proteins on the fracture resistance of this unique structural material. Sections of enamel were obtained from the cusps of human molars and the crack growth resistance was quantified using a conventional fracture mechanics approach with complementary finite element analysis. In selected specimens the proteins were extracted using a potassium hydroxide treatment. Removal of the proteins resulted in approximately 40% decrease in the fracture toughness with respect to the fully proteinized control. The loss of organic content was most detrimental to the extrinsic toughening mechanisms, causing over 80% reduction in their contribution to the total energy to fracture. This degradation occurred by embrittlement of the unbroken bridging ligaments and consequent reduction in the crack closure stress. Although the organic content of tooth enamel is very small, it is essential to crack growth toughening by facilitating the formation of unbroken ligaments and in fortifying their potency. Replicating functions of the organic content will be critical to the successful development of bio-inspired materials that are designed for fracture resistance. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Emergency department management of pain and anxiety related to orthopedic fracture care: a guide to analgesic techniques and procedural sedation in children.

    PubMed

    Kennedy, Robert M; Luhmann, Jan D; Luhmann, Scott J

    2004-01-01

    Orthopedic fractures and joint dislocations are among the most painful pediatric emergencies. Safe and effective management of fracture-related pain and anxiety in the emergency department reduces patient distress during initial evaluation and often allows definitive management of the fracture. No consensus exists on which pharmacologic regimens for procedural sedation/analgesia are safest and most effective. For some children, control of fracture pain is the primary goal, whereas for others, relief from anxiety is an additionally important objective. Furthermore, strategies for the management of fracture pain may vary by fracture location and patient characteristics; thus, no single regimen is likely to provide the best means of analgesia and anxiolysis for all patients. Effective analgesia can be provided by local or regional anesthesia, such as hematoma, Bier, or nerve blocks. Alternatively, induction of deep sedation with analgesic agents such as ketamine or fentanyl, often combined with sedative-anxiolytic agents such as midazolam, may be used to manage distress associated with fracture reduction. A combination of local anesthesia with moderate sedation, for example nitrous oxide, is another attractive option.

  17. Relationship between compliance and persistence with osteoporosis medications and fracture risk in primary health care in France: a retrospective case-control analysis.

    PubMed

    Cotté, François-Emery; Mercier, Florence; De Pouvourville, Gérard

    2008-12-01

    Nonadherence to treatment is an important determinant of long-term outcomes in women with osteoporosis. This study was conducted to investigate the association between adherence and osteoporotic fracture risk and to identify optimal thresholds for good compliance and persistence. A secondary objective was to perform a preliminary evaluation of the cost consequences of adherence. This was a retrospective case-control analysis. Data were derived from the Thales prescription database, which contains information on >1.6 million patients in the primary health care setting in France. Cases were women aged >or=50 years who had an osteoporosis-related fracture in 2006. For each case, 5 matched controls were randomly selected. Both compliance and persistence aspects of treatment adherence were examined. Compliance was estimated based on the medication possession ratio (MPR). Persistence was calculated as the time from the initial filling of a prescription for osteoporosis medication until its discontinuation. The mean (SD) MPR was lower in cases compared with controls (58.8% [34.7%] vs 72.1% [28.8%], respectively; P < 0.001). Cases were more likely than controls to discontinue osteoporosis treatment (50.0% vs 25.3%; P < 0.001), yielding a significantly lower proportion of patients who were still persistent at 1 year (34.1% vs 40.9%; P < 0.001). MPR was the best predictor of fracture risk, with an area under the receiver-operating-characteristic curve that was higher than that for persistence (0.59 vs 0.55). The optimal MPR threshold for predicting fracture risk was >or=68.0%. Compared with less-compliant women, women who achieved this threshold had a 51% reduction in fracture risk. The difference in annual drug expenditure between women achieving this threshold and those who did not was approximately euro300. The optimal threshold for persistence with therapy was at least 6 months. Attaining this threshold was associated with a 28% reduction in fracture risk compared with less-persistent women. In this study, better treatment adherence was associated with a greater reduction in fracture risk. Compliance appeared to predict fracture risk better than did persistence.

  18. Open reduction and internal fixation of Ideberg IV and V glenoid intra-articular fractures through a Judet approach: a retrospective analysis of 11 cases.

    PubMed

    Hu, Chuanzhen; Zhang, Weibin; Qin, Hui; Shen, Yuhui; Xue, Zichao; Ding, Haoliang; An, Zhiquan

    2015-02-01

    To evaluate the methods and the outcomes of complex intra-articular glenoid fractures, treated by open reduction and internal fixations. The outcomes of 11 cases of complex intra-articular glenoid scapular fractures were retrospectively analyzed. The fractures were classified as type IV in five cases, type Va in two and Vb in four cases, according to Ideberg classification system. The mean step or gap between the main articular fragments was 6.3 ± 6.2 (4-25) mm. The fractures were openly reduced through a Judet approach and fixed with reconstructive plates or bands placed on the lateral and medial side of affected scapula, respectively. The main articular fragments were strengthened with a 4.0-mm cannulated screw in five cases. The bone union, the anterior flexion, the external and internal rotation of the shoulders were checked and recorded. The functional outcomes were evaluated using DASH questionnaire, Constant and UCLA shoulder score systems, respectively. 11 patients were followed up with an average of 28.2 ± 12.6 (12-50) months. All the fractures were united smoothly without second intervention. At the latest visiting, the mean anterior flexion of affected shoulder was 157.3 ± 7.37° (range 150°-170°), the mean external rotation of the affected shoulder was 58.2 ± 7.5° (range 50°-70°). When the shoulder in the internal rotation, the extended thumb reached to L4 or L1 or T10 or T7 in one case, to T12 in two cases and to T8 in four cases, respectively, the mean Constant score was 91.7 ± 2.8 (86-96) points. The mean UCLA score was 32.7 ± 1.7 (30-35) points, leading to four cases of excellent and seven cases of good results. The mean DASH score was 7.4 ± 3.3 (3.4-13) points. Good outcomes could be obtained when Ideberg IV and V glenoid fractures were treated by open reduction and internal fixation through a Judet approach.

  19. Femoral fracture repair and postoperative management in new zealand white rabbits.

    PubMed

    Reuter, Jon D; Ovadia, Shira; Howell, Paula; Jaskwich, David H

    2002-07-01

    Low bone density and large muscle mass predispose rabbits to femoral fractures. However, there are few reports describing treatment and prognosis. Two New Zealand White rabbits presented with unilateral left rear limb abduction and lateral rotation of the distal left rear limb 2 and 17 days after experimental surgery to create a "stair step" in the patellar groove of the left medial femoral chondyle. This procedure was performed after approval by the Institutional Animal Care and Use Committee. Radiography revealed a spiral oblique mid-shaft fracture of the left femur in both rabbits. Open fracture reduction was undertaken. Because of the presence of screws and Kirschner-wires in the medial femoral condyle, a lateral approach to surgical correction was chosen. Intramedullary fixation was used to reduce and stabilize the fractures. A 0.062" Kirschner wire was selected for the intramedullary device, because it was sufficiently flexible to allow easy passage into the femoral canal while being sufficiently stiff to promote reduction of the fracture. In addition, the ends of the fracture were secured with a 0.032" Kirschner cerclage wire to provide additional control of rotation and angulation. Then we assessed the range of motion of the knee joint to determine fracture stability and ensure that the hardware did not impinge on soft-tissue elements. After closure and application of sterile dressing, the hind legs were hobbled proximal to the hock by using elastic veterinary wrap in a figure-eight pattern to maintain limb alignment and prevent formation of pressure ulcers. Intraoperative fluoroscopic evaluation and postoperative radiographs confirmed fracture reduction. Bruising and seroma formation occurred at the surgical site, and transient anorexia developed. Rabbits were treated with fluids, analgesics, antibiotics, and fitted with Elizabethan collars. They were housed in isolation to limit excessive environmental stimulation, which could alarm them and provoke "thumping" of the rear legs. Muscular weakness and atrophy developed in the affected legs, but the fractures remained immobilized. Radiographs obtained 21 days after surgery confirmed marked callus formation and integrity of the implanted hardware. Four weeks after surgical fixation, both rabbits showed increased muscle development in the repaired leg and were ambulating normally. The long-term prognosis was excellent. These cases demonstrate that repair of femoral fractures in rabbits can be achieved by using basic orthopedic techniques and diligent post-operative management.

  20. [Manipulative reduction and percutaneous Kirschner wire internal fixation for grade IV supination-external rotation ankle fractures].

    PubMed

    Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin

    2017-06-25

    To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.

  1. Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures.

    PubMed

    Burnei, C; Popescu, Gh; Barbu, D; Capraru, F

    2011-11-14

    Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach.

  2. Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures

    PubMed Central

    Burnei, C; Popescu, Gh; Barbu, D; Capraru, F

    2011-01-01

    Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach. PMID:22514563

  3. Double row anchor fixation: a novel technique for a diabetic calanceal insufficiency avulsion fracture.

    PubMed

    Greenhagen, Robert M; Highlander, Peter D; Burns, Patrick R

    2012-01-01

    Avulsion fractures of the calcaneal tuberosity represent only 1.3% to 2.7% of calcaneal fractures. These fractures are common pathologically in nature and attributed to decreased bone mineral density. Calcaneal insufficiency avulsion (CIA) fracture in patients with diabetes mellitus is most likely due to Charcot neuroarthropathy (CN) as described by the Brodsky classification (Brodsky 3B). Traditional open reduction and internal fixation is difficult in all calcaneal avulsion fractures because of poor bone quality. The authors report the first known description of the use of fracture fragment excision and double row anchor fixation.A 39-year-old woman with type I diabetes mellitus and a history of CN presented with an avulsion fracture of the calcaneal tuberosity. Excision of the fracture fragment and a gastrocnemius recession and reattachment of the Achilles tendon with double row anchor fixation to the calcaneus were performed. At 1 year, the patient's American Orthopaedic Foot & Ankle Society rearfoot score improved from 27/100 to 88/100. CIA fractures are an infrequently described injury. Because diabetes mellitus is frequently associated with this disease, it most likely represents a CN event. Traditionally, CIA fractures have been operatively treated with open reduction internal fixation. Previous authors have described difficulty with fixation because of poor quality. In the current report, the authors describe a novel operative approach to CIA fractures through the use of double row anchor fixation and excision of the fracture fragments. The authors feel that this previously undescribed treatment is superior to traditional methods and may serve as a new treatment option for all patients who have sustained this unusual pathology regardless of the underlying cause. The current authors provide a novel operative technique that provides inherent advantages to the traditional repair of CIA fractures. We believe CIA fractures represent a CN-type event and care should be taken when evaluating and treating these patients to prevent further sequelae. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. A Novel Technique for Closed Reduction and Fixation of Paediatric Calcaneal Fracture Dislocation Injuries

    PubMed Central

    Faroug, Radwane; Stirling, Paul; Ali, Farhan

    2013-01-01

    Paediatric calcaneal fractures are rare injuries usually managed conservatively or with open reduction and internal fixation (ORIF). Closed reduction was previously thought to be impossible, and very few cases are reported in the literature. We report a new technique for closed reduction using Ilizarov half-rings. We report successful closed reduction and screwless fixation of an extra-articular calcaneal fracture dislocation in a 7-year-old boy. Reduction was achieved using two Ilizarov half-ring frames arranged perpendicular to each other, enabling simultaneous application of longitudinal and rotational traction. Anatomical reduction was achieved with restored angles of Bohler and Gissane. Two K-wires were the definitive fixation. Bony union with good functional outcome and minimal pain was achieved at eight-weeks follow up. ORIF of calcaneal fractures provides good functional outcome but is associated with high rates of malunion and postoperative pain. Preservation of the unique soft tissue envelope surrounding the calcaneus reduces the risk of infection. Closed reduction prevents distortion of these tissues and may lead to faster healing and mobilisation. Closed reduction and screwless fixation of paediatric calcaneal fractures is an achievable management option. Our technique has preserved the soft tissue envelope surrounding the calcaneus, has avoided retained metalwork related complications, and has resulted in a good functional outcome. PMID:23819090

  5. Prevention of arthrofibrosis after arthroscopic screw fixation of tibial spine fracture in children and adolescents.

    PubMed

    Parikh, Shital N; Myer, David; Eismann, Emily A

    2014-01-01

    Arthrofibrosis is a major complication of tibial spine fracture treatment in children, potentially resulting in knee pain, quadriceps weakness, altered gait, decreased function, inability to return to sports, and long-term osteoarthritis. Thus, prevention rather than treatment of arthrofibrosis is desirable. The purpose of this study was to evaluate an aggressive postoperative rehabilitation and early intervention approach to prevent permanent arthrofibrosis after tibial spine fracture treatment and to compare epiphyseal and transphyseal screws for fixation. A consecutive series of 24 patients younger than age 18 with displaced type II and III tibial spine fractures who underwent arthroscopic reduction and screw fixation between 2006 and 2011 were retrospectively reviewed. Final range of motion was compared between patients with epiphyseal (n=12) and transphyseal (n=9) screws. One-third (4 of 12) of patients with epiphyseal screws underwent arthroscopic debridement and screw removal approximately 3 months postoperatively; 3 patients lacked 5° to 15° of extension, 1 experienced pain with extension, and 1 had radiographic evidence of screw pullout, loss of reduction, and resultant malunion. In the transphyseal screw group, 3 patients had 10° loss of extension, and all corrected after arthroscopic debridement and screw removal. The two groups did not significantly differ in time to hardware removal or return to sports or final range of motion. No growth disturbances were identified in patients after transphyseal screw removal. An aggressive approach of postoperative rehabilitation and early intervention after arthroscopic reduction and screw fixation of tibial spine fractures in children was successful in preventing permanent arthrofibrosis.

  6. Results of minimal invasive coracoclavicular fixation by double button lift-up system in Neer type II distal clavicle fractures.

    PubMed

    Dedeoğlu, Süleyman Semih; İmren, Yunus; Çabuk, Haluk; Çakar, Murat; Arslan, Samet Murat; Esenyel, Cem Zeki

    2017-01-01

    We aimed to evaluate clinical and functional outcomes of indirect fracture reduction performed by coracoclavicular fixation with minimal invasive double button lift-up system in Neer type IIa unstable fractures of distal clavicle. 22 patients with Neer type 2 distal clavicle fracture were enrolled in that prospective study. All patients underwent indirect reduction and osteosynthesis performed by coracoclavicular fixation with minimal invasive double button lift-up system. Postoperative follow-up was carried out clinically and radiologically with plain X-rays and utilization of Constant and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (ASES) shoulder scores. Mean follow-up time was 15 months. A standard sling was applied for 2 weeks, postoperatively. Rehabilitation program was started on postoperative day 1. Mean age was 39 (range: 21-60), 18 of the patients were male. Right dominant extremity was affected in 14 patients. Mean duration of the surgical intervention was 40 min (range: 30-55 min). Mean union time was found to be 14 weeks (range: 7-21 weeks). Mean postoperative ASES and Constant scores were 79.9 (66.9-88.3) and 82.2 (71-100), respectively. The duration of return to normal daily activities were found to be 4.5 months. Any loss of reduction, AC joint arthrosis, and clavicular shortening were not detected in X-rays. This study has demonstrated that indirect osteosynthesis performed by coracoclavicular fixation with double button lift-up system in the treatment of unstable Neer type IIa fractures of the distal clavicle had successful clinical, radiological, and functional outcomes.

  7. Health state utility values and patient-reported outcomes before and after vertebral and non-vertebral fractures in an osteoporosis clinical trial.

    PubMed

    Imai, T; Tanaka, S; Kawakami, K; Miyazaki, T; Hagino, H; Shiraki, M

    2017-06-01

    We assessed the health state utility value (HSUV) reductions associated with vertebral fractures using data collected in the Japanese Osteoporosis Intervention Trial-03 (JOINT-03). Our analysis revealed that assessment of HSUVs after morphometric vertebral fracture is important to capture the burden of vertebral fractures. Evaluation of the HSUV after fracture is important to calculate the quality-adjusted life years (QALYs) of osteoporosis patients, which is essential information in the context of health economic evaluation. JOINT-03 study patients were aged ≥65 years and treated with risedronate and vitamin K 2 or risedronate alone. Radiographic information and patient-reported outcomes measured by EQ-5D and a visual analogue scale (VAS) were assessed at registration and followed up after 6, 12, and 24 months. According to differences among the dates of these assessments and the radiographic information, we classified the follow-up HSUVs calculated based on EQ-5D results into before or after fracture categories regardless of clinical symptoms. Among 2922 follow-up HSUVs, 201 HSUVs were categorized as HSUVs that were observed after incident vertebral fractures on X-ray films. The median time from the detection of an incident vertebral fracture until the EQ-5D assessment was 53 days (25th percentile, 0 day; 75th percentile, 357 days). The impact of incident vertebral fractures on HSUVs was quantified as -0.03. Among the five health profile domains on the EQ-5D, an incident vertebral fracture had significant effects on anxiety/depression, self-care, and usual activities. The results suggest that incident morphometric vertebral fracture was associated with impairment of the HSUV for patients with osteoporosis not only immediately but also several months after the fracture.

  8. Evaluation of stability of osteosynthesis with K-wires on an artificial model of tibial malleolus fracture.

    PubMed

    Bumči, Igor; Vlahović, Tomislav; Jurić, Filip; Žganjer, Mirko; Miličić, Gordana; Wolf, Hinko; Antabak, Anko

    2015-11-01

    Paediatric ankle fractures comprise approximately 4% of all paediatric fractures and 30% of all epiphyseal fractures. Integrity of the ankle "mortise", which consists of tibial and fibular malleoli, is significant for stability and function of the ankle joint. Tibial malleolar fractures are classified as SH III or SH IV intra-articular fractures and, in cases where the fragments are displaced, anatomic reposition and fixation is mandatory. Type SH III-IV fractures of the tibial malleolus are usually treated with open reduction and fixation with cannulated screws that are parallel to the physis. Two K-wires are used for temporary stabilisation of fragments during reduction. A third "guide wire" for the screw is then placed parallel with the physis. Considering the rules of mechanics, it is assumed that the two temporary pins with the additional third pin placed parallel to the physis create a strong triangle and thus provide strong fracture fixation. To prove this hypothesis, an experiment was conducted on the artificial models of the lower end of the tibia from the company "Sawbones". Each model had been sawn in a way that imitates the fracture of medial malleoli and then reattached with 1.8mm pins in various combinations. Prepared models were then tested for tensile and pressure forces. The least stable model was that in which the fractured pieces were attached with only two parallel pins. The most stable model comprised three pins, where two crossed pins were inserted in the opposite compact bone and the third pin was inserted through the epiphysis parallel with and below the growth plate. A potential method of choice for fixation of tibial malleolar fractures comprises three K-wires, where two crossed pins are placed in the opposite compact bone and one is parallel with the growth plate. The benefits associated with this method include shorter operating times and avoidance of a second operation for screw removal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Complications of the retromandibular transparotid approach for low condylar neck and subcondylar fractures: a retrospective study

    PubMed Central

    2018-01-01

    Objectives The goal of this study was to evaluate the rates of complications, morbidity, and safety with the transparotid approach. Materials and Methods A retrospective study was conducted and consisted of 53 surgically treated patients in the past five years for low condylar neck and subcondylar fractures. Only patients with malocclusion and who underwent open reduction with internal fixation with the retromandibular transparotid approach were included. The examined parameters were postoperative suboptimal occlusion, deflection, saliva fistula, and facial nerve weakness. Results Fifty-three patients had an open reduction with internal fixation on 55 sides (41 males, 77.4%; mean age, 42 years [range, 18–72 years]). Four patients (7.5%) experienced transient facial nerve weakness of the marginal mandibular branch, but none was permanent. Four patients had a salivary fistula, and 5 patients showed postoperative malocclusion, where one needed repeat surgery after one year. One patient showed long-term deflection. No other complications were observed. Conclusion The retromandibular transparotid approach is a safe procedure for open reduction and internal fixation of low condylar neck and subcondylar fractures, and it has minimal complications. PMID:29732312

  10. A Fracture Decoupling Experiment

    NASA Astrophysics Data System (ADS)

    Stroujkova, A. F.; Bonner, J. L.; Leidig, M.; Ferris, A. N.; Kim, W.; Carnevale, M.; Rath, T.; Lewkowicz, J.

    2012-12-01

    Multiple observations made at the Semipalatinsk Test Site suggest that conducting nuclear tests in the fracture zones left by previous explosions results in decreased seismic amplitudes for the second nuclear tests (or "repeat shots"). Decreased seismic amplitudes reduce both the probability of detection and the seismically estimated yield of a "repeat shot". In order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fractured rocks, Weston Geophysical Corp., in collaboration with Columbia University's Lamont Doherty Earth Observatory, conducted a multi-phase Fracture Decoupling Experiment (FDE) in central New Hampshire. The FDE involved conducting explosions of various yields in the damage/fracture zones of previously detonated explosions. In order to quantify rock damage after the blasts we performed well logging and seismic cross-hole tomography studies of the source region. Significant seismic velocity reduction was observed around the source regions after the initial explosions. Seismic waves produced by the explosions were recorded at near-source and local seismic networks, as well as several regional stations throughout northern New England. Our analysis confirms frequency dependent seismic amplitude reduction for the repeat shots compared to the explosions in un-fractured rocks. The amplitude reduction is caused by pore closing and/or by frictional losses within the fractured media.

  11. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures

    PubMed Central

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2014-01-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3–12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact. PMID:26269728

  12. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    PubMed

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. Distal Radius Fractures Do Not Displace following Splint or Cast Removal in the Acute, Postreduction Period: A Prospective, Observational Study.

    PubMed

    Foster, Brock D; Sivasundaram, Lakshmanan; Heckmann, Nathanael; Pannell, William C; Alluri, Ram K; Ghiassi, Alidad

    2017-02-01

    Background  Displacement of distal radius fractures has been previously described in the literature; however, little is known about fracture displacement following splint or cast removal at the initial clinic visit following reduction and immobilization. Purpose  The purpose of this study was to evaluate risk factors for fracture displacement following splint or cast removal and physical examination in the acute postinjury period. Methods  All patients with a closed distal radius fracture who presented to our orthopedic hand clinic within 3 weeks of injury were prospectively enrolled in our study. Standard wrist radiographs were obtained prior to splint or cast removal. A second wrist series was obtained following physical exam and application of immobilization at the end of the clinic visit. Radiographic parameters for displacement were measured by two independent reviewers and included dorsal angulation, radial inclination, articular step-off, radial height, and ulnar variance. Displacement was assessed using predefined, radiographic criteria for displacement. Results  A total of 64 consecutive patients were enrolled over a period of 12 weeks. Of these, 37.5% were classified as operative according to American Academy of Orthopaedic Surgeons guidelines and 37.5% met LaFontaine instability criteria. For each fracture, none of the five measurements exceeded the predefined clinically or statistically significant criteria for displacement. Conclusion  Splint removal in the acute postinjury period did not result in distal radius fracture displacement. Clinicians should feel comfortable removing splints and examining underlying soft tissue in the acute setting for patients with distal radius fractures after closed reduction. Level of Evidence  Level II, prospective comparative study.

  14. Endoscopic transnasal approach for the treatment of isolated medial orbital blow-out fractures: a prospective study of preoperative and postoperative orbital volume change.

    PubMed

    Kim, KyoungHoon; Song, KyeongHo; Choi, SooJong; Bae, YongChan; Choi, ChiWon; Oh, HeungChan; Lee, JaeWoo; Nam, SuBong

    2012-02-01

    Endoscopic transnasal reduction is a safe and effective technique for the treatment of blow-out fractures of the medial orbital wall. However, because this approach does not use rigid permanent material for reconstruction of the fractured medial orbital wall, some degree of herniation of the orbital contents may occur after the intraethmoidal packing material is removed. The purpose of this study was to evaluate the change in orbital volume in patients with medial orbital wall fractures treated through an endoscopic transnasal approach. This study was a prospective analysis that includes 20 patients who underwent endoscopic transnasal reduction of medial orbital wall fractures between April 2007 and December 2008. Computer-assisted orbital volume measurements were made using axial computed tomography. The mean (standard deviation [SD]) volume increase was 2.00 (0.92) cm(3) and the mean (SD) dimension of the fractured orbital wall was 2.76 (0.83) cm(2). After endoscopic surgery, an average (SD) volume decrease of 2.15 (0.91) cm(3) was achieved with ethmoid sinus packing. After removal of the packing materials, 1.14 (0.78) cm(3) increase of the orbital volume was observed. The dimension of the orbital wall fracture significantly correlated with the increased preoperative orbital volume (P = 0.002, r = 0.609); the preoperative increase in the orbital volume also significantly correlated with volume relapse after removal of the packing (P = 0.023, r = 0.452). These findings suggest that in broad orbital wall fractures, reconstruction of the orbital wall by rigid materials or prolongation of the packing period should be considered, because orbital volume can increase again after packing removal, and may thus lead to postoperative complications.

  15. Maxillofacial fracture experiences: a review of 152 cases.

    PubMed

    Aydin, Osman Enver; Tan, Onder; Algan, Said; Kuduban, Selma Denktas; Barin, Ensar Zafer; Cinal, Hakan; Sarici, Murat; Avsar, Umit

    2012-12-01

    The fractures of facial structures lead to great morbidity. Cross-sectional studies are needed to evaluate the current state of maxillofacial traumas. Thus, this study aims to evaluate these experiences and to compare these results with the current literature. The medical records of the maxillofacial fracture cases hospitalized between January 2004 and November 2011 were examined. The age, sex, etiology, fracture localization and treatment method for each case were documented. The affected facial bones were grouped as mandible, maxilla, zygoma, naso-orbitoethmoid complex (NOEC) and blow-out. Nasal fractures were excluded. The cases were assigned to 3 groups with respect to age (below 16, above 65 and between 17 and 64). The chi Square test was used to assess the significance of the difference in mandibular fracture rates in the pediatric population compared to others. The total number of cases was 152. The total number of fractures was 185. Of the 152 cases, 117 were male and 35 were female. The average age was 31.4 (±18.3), ranging between 2 and 81. Thirty-one cases were 16 years old or less. Nine cases were 65 years old or more. Mandibular and zygomatic fractures were the most prevalent fractures in the adult group. Mandibular fractures were significantly more common in the pediatric age group compared to rest of the population (X(2), p<0.05). Traffic accidents were the most common etiological factor, with a 55.3% ratio. Open reduction and internal fixation was the most frequently conducted treatment modality in all age groups. Retrospective studies are important for the projection of future prospects. In summary, our results indicate that pediatric fractures are mostly in the lower face and usually affect the condylar region, which is consistent with the literature.

  16. EXTRA-ARTICULAR FRACTURE OF THE MEDIAL END OF THE CLAVICLE ASSOCIATED WITH TYPE IV ACROMIOCLAVICULAR DISLOCATION: CAAE REPORT

    PubMed Central

    Correa, Mário Chaves; Gonçalves, Lucas Braga Jacques; Vilela, Jose Carlos Souza; Leonel, Igor Lima; Costa, Lincoln Paiva; de Andrade, Ronaldo Percopi

    2015-01-01

    Fractures of the clavicle and acromioclavicular dislocations are very common injuries when they occur separately. The combination of an acromioclavicular dislocation and a fracture of the lateral third of the clavicle is not rare. However, there are very few reported cases of acromioclavicular dislocations associated with fractures of the middle third of the clavicle; those associated with fractures of the medial third are even rarer. We report the case of an adult male who suffered an acromioclavicular dislocation (type IV) associated with a displaced extra-articular fracture of the medial end of the clavicle (Almann group 3) in a cycling accident. The patient was treated during the acute phase with open reduction and internal fixation of the two lesions. At the clinical evaluation 12 months after the surgery, the patient was asymptomatic, with full active and passive mobility, and normal strength and endurance of the shoulder girdle. Radiographs and a three-dimensional CT scan showed persistent posterosuperior subluxation of the acromioclavicular joint and anatomical consolidation of the clavicular fracture. PMID:27027060

  17. EXTRA-ARTICULAR FRACTURE OF THE MEDIAL END OF THE CLAVICLE ASSOCIATED WITH TYPE IV ACROMIOCLAVICULAR DISLOCATION: CAAE REPORT.

    PubMed

    Correa, Mário Chaves; Gonçalves, Lucas Braga Jacques; Vilela, Jose Carlos Souza; Leonel, Igor Lima; Costa, Lincoln Paiva; de Andrade, Ronaldo Percopi

    2011-01-01

    Fractures of the clavicle and acromioclavicular dislocations are very common injuries when they occur separately. The combination of an acromioclavicular dislocation and a fracture of the lateral third of the clavicle is not rare. However, there are very few reported cases of acromioclavicular dislocations associated with fractures of the middle third of the clavicle; those associated with fractures of the medial third are even rarer. We report the case of an adult male who suffered an acromioclavicular dislocation (type IV) associated with a displaced extra-articular fracture of the medial end of the clavicle (Almann group 3) in a cycling accident. The patient was treated during the acute phase with open reduction and internal fixation of the two lesions. At the clinical evaluation 12 months after the surgery, the patient was asymptomatic, with full active and passive mobility, and normal strength and endurance of the shoulder girdle. Radiographs and a three-dimensional CT scan showed persistent posterosuperior subluxation of the acromioclavicular joint and anatomical consolidation of the clavicular fracture.

  18. Displaced intra-articular calcaneal fractures.

    PubMed

    Bajammal, Sohail; Tornetta, Paul; Sanders, David; Bhandari, Mohit

    2005-01-01

    Calcaneal fractures comprise 1 to 2 percent of all fractures. Approximately 75% of calcaneal fractures are intra-articular. The management of intra-articular calcaneal fractures remains controversial. Nonoperative treatment options include elevation, ice, early mobilization, and cyclic compression of the plantar arch. Operative treatment options include closed reduction and percutaneous pin fixation, open reduction and internal fixation, and arthrodesis. The effect of operative versus nonoperative treatment has been the focus of several comparative studies. This study was designed to determine the effect of operative treatment compared with nonoperative treatment on the rate of union, complications, and functional outcome after intra-articular calcaneal fracture in adults.

  19. Avascular necrosis of the femoral head after osteosynthesis of femoral neck fracture.

    PubMed

    Min, Byung-Woo; Kim, Sung-Jin

    2011-05-18

    The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. We evaluated the incidence of avascular necrosis of the femoral head with the use of contemporary techniques for femoral neck fracture fixation. We then sought to determine what potential risk factors influenced the development of avascular necrosis.Between 1990 and 2005, one hundred sixty-three intracapsular femoral neck fractures in 163 patients were treated with internal fixation at our level-I trauma center. All patients were monitored until conversion to total hip arthroplasty or for a minimum of 2 years postoperatively. Ten patients (10 hips) died and 7 patients (7 hips) were lost to follow-up. The remaining 146 patients (146 hips) had a mean 5.2 years of follow-up (range, 3 months to 17 years). The incidence of avascular necrosis was 25.3% (37 hips). The average time to diagnosis of avascular necrosis was 18.8 months (range, 3-47 months). Patient sex, age, interval from injury to surgery, and mechanism of injury were statistically not associated with the development of avascular necrosis. The quality of fracture reduction, adequacy of fixation, degree of displacement, and comminution of the posterior cortex were significantly associated. After we controlled for patient and radiographic characteristics, multivariate analyses indicated that the important predictors for avascular necrosis are poor reduction (odds ratio=13.889) and initial displacement of the fracture (odds ratio=4.693). Copyright 2011, SLACK Incorporated.

  20. Reduction of rib fractures with a bioresorbable plating system: preliminary observations.

    PubMed

    Vu, Kim-Chi; Skourtis, Mia E; Gong, Xi; Zhou, Minhao; Ozaki, Wayne; Winn, Shelley R

    2008-05-01

    Operative fixation of rib fractures can reduce morbidity and mortality. Currently, resorbable fixation devices are used in a variety of surgical procedures. A standard osteotomy was prepared in 30 New Zealand white rabbits at the 12th rib. Eighteen had surgical repair with bioresorbable plates and 12 underwent nonoperative management. Half the animals in each group were killed at 3-week postfracture and the remaining animals were killed at 6-week postfracture. Ribs were radiographed and processed histologically to assess fracture healing. Rib reduction was defined as the alignment of the rib ends in a structural condition similar to the prefractured state and quantitative radiomorphometry measured the radiopaque callus surrounding the rib injury sites. Statistical analysis was performed using Fisher's exact test and an unpaired Student's t test and significance was established at p < 0.05. At both the 3- and 6-week intervals, seven of the nine rib fractures remained reduced in the operative group, whereas zero of six and three of six of the rib fractures remained reduced, respectively, in the nonoperative group. A statistically significant increase in radiopaque callus surrounding the rib injury sites was observed at 3 and 6 weeks in the fixed groups. Fixation of rib fractures with a bioresorbable miniplate system was superior to nonoperative treatment at the 3-week interval, with a statistically significant increase in radiopaque callus formation at both 3 and 6 weeks. Additional studies will evaluate the biomechanical outcomes and degradation tissue response after extended in vivo intervals.

  1. The application of the Risdon approach for mandibular condyle fractures.

    PubMed

    Nam, Seung Min; Lee, Jang Hyun; Kim, Jun Hyuk

    2013-07-06

    Many novel approaches to mandibular condyle fracture have been reported, but there is a relative lack of reports on the Risdon approach. In this study, the feasibility of the Risdon approach for condylar neck and subcondylar fractures of the mandible is demonstrated. A review of patients with mandibular condylar neck and subcondylar fractures was performed from March 2008 to June 2012. A total of 25 patients, 19 males and 6 females, had 14 condylar neck fractures and 11 subcondylar fractures. All of the cases were reduced using the Risdon approach. For subcondylar fractures, reduction and fixation with plates was done under direct vision. For condylar neck fractures, reduction and fixation was done with the aid of a trochar in adults and a percutaneous threaded Kirschner wire in children. There were no malunions or nonunions revealed in follow-up care. Mild transient neuropraxia of the marginal mandibular nerve was seen in 4 patients, which was resolved within 1-2 months. The Risdon approach is a technique for reducing the condylar neck and subcondylar fractures that is easy to perform and easy to learn. Its value in the reduction of mandibular condyle fractures should be emphasized.

  2. The application of the Risdon approach for mandibular condyle fractures

    PubMed Central

    2013-01-01

    Background Many novel approaches to mandibular condyle fracture have been reported, but there is a relative lack of reports on the Risdon approach. In this study, the feasibility of the Risdon approach for condylar neck and subcondylar fractures of the mandible is demonstrated. Methods A review of patients with mandibular condylar neck and subcondylar fractures was performed from March 2008 to June 2012. A total of 25 patients, 19 males and 6 females, had 14 condylar neck fractures and 11 subcondylar fractures. Results All of the cases were reduced using the Risdon approach. For subcondylar fractures, reduction and fixation with plates was done under direct vision. For condylar neck fractures, reduction and fixation was done with the aid of a trochar in adults and a percutaneous threaded Kirschner wire in children. There were no malunions or nonunions revealed in follow-up care. Mild transient neuropraxia of the marginal mandibular nerve was seen in 4 patients, which was resolved within 1–2 months. Conclusions The Risdon approach is a technique for reducing the condylar neck and subcondylar fractures that is easy to perform and easy to learn. Its value in the reduction of mandibular condyle fractures should be emphasized. PMID:23829537

  3. [POKING REDUCTION TREATMENT OF DISPLACED SCAPULAR NECK FRACTURE WITH SHOULDER ARTHROSCOPY-ASSISTED SURGERY].

    PubMed

    Qu, Feng; Yuan, Bangtuo; Qi, Wei; Wang, Junliang; Shen, Xuezhen; Wang, Jiangtao; Zhao, Gang; Liu, Yujie

    2014-07-01

    To discuss the effectiveness of Poking reduction with shoulder arthroscopy-assisted surgery for displaced scapular neck fracture. Between January 2009 and January 2012, 9 cases of displaced scapular neck fracture underwent shoulder arthroscopy-assisted surgery for Poking reduction treatment. Of 9 cases, 6 were men, and 3 were women, aged 21-54 years (mean, 39 years). The causes were traffic accident injury in 7 cases, falling injury from height in 1 case, and hurt injury in 1 case. The shoulder abduction, flexion, and external rotation were obviously limited. X-ray films showed all cases had obvious displaced scapular neck fracture. Three-dimensional reconstruction of CT showed a grossly displaced of fracture. The time of injury to surgery was 4-27 days (mean, 11 days). Patients obtained healing of incision by first intension, without infection, neurovascular injury, or other surgery-related complications. All patients were followed up 19- 31 months (mean, 23 months). X-ray films showed scapular neck fractures healed from 7 to 11 weeks (mean, 8 weeks). At last follow-up, the shoulder abduction, flexion, and external rotation activity were improved significantly when compared with ones at preoperation (P < 0.05); the shoulder Constant score, American Shoulder and Elbow Surgenos (ASES) score, and Rowe score were significantly better than preoperative scores (P < 0.05). The reduction of displaced scapular neck fracture is necessary, and arthroscopic Poking reduction and fixation for displaced scapular neck fracture can reconstruct the shoulder stability and reduce complications.

  4. The Anterior Intrapelvic Approach for Acetabular Fractures Using Approach-Specific Instruments and an Anatomical-Preshaped 3-Dimensional Suprapectineal Plate.

    PubMed

    Gras, Florian; Marintschev, Ivan; Grossterlinden, Lars; Rossmann, Markus; Graul, Isabel; Hofmann, Gunther O; Rueger, Johannes M; Lehmann, Wolfgang

    2017-07-01

    Anatomical acetabular plates the anterior intrapelvic approach (AIP) were recently introduced to fix acetabular fractures through the intrapelvic approach. Therefore, we asked the following: (1) Does the preshaped 3-dimensional suprapectineal plate interfere with or even impair the fracture reduction quality? (2) How often does the AIP approach need to be extended by the first (lateral) window of the ilioinguinal approach? Observational case series. Two Level 1 trauma centers. Patients with unstable acetabular fractures in 2014. Fracture fixation with anatomical-preshaped, 3-dimensional suprapectineal plates through the AIP approach ± the first window of the ilioinguinal approach. Fracture reduction results were measured in computed tomography scans and graded according to the Matta quality of reduction. Intraoperative parameters and perioperative complications were recorded. Radiological results (according to Matta) and functional outcome (modified Merle d'Aubigné score) were evaluated at 1-year follow-up. Thirty patients (9 women + 21 men; mean age ± SE: 64 ± 8 years) were included. The intrapelvic approach was solely used in 19 cases, and in 11 cases, an additional extension with the first window of the ilioinguinal approach (preferential for 2-column fractures) was performed. The mean operating time was 202 ± 59 minutes; the fluoroscopic time was 66 ± 48 seconds. Fracture gaps and steps in preoperative versus postoperative computed tomography scans were 12.4 ± 9.8 versus 2.0 ± 1.5 and 6.0 ± 5.5 versus 1.3 ± 1.7 mm, respectively. At 13.4 ± 2.9 months follow-up, the Matta grading was excellent in 50%, good in 25%, fair in 11%, and poor in 14% of cases. The modified Merle d'Aubigné score was excellent in 17%, good in 37%, fair in 33%, and poor in 13% of cases. The AIP approach using approach-specific instruments and an anatomical-preshaped, 3-dimensional suprapectineal plate became the standard procedure in our departments. Radiological and functional early results justify joint preserving surgery in most cases. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  5. Minimally invasive treatment of pilon fractures with a low profile plate: preliminary results in 17 cases.

    PubMed

    Borens, Olivier; Kloen, Peter; Richmond, Jeffrey; Roederer, Goetz; Levine, David S; Helfet, David L

    2009-05-01

    To determine the results of "biologic fixation" with a minimally invasive plating technique using a newly designed low profile "Scallop" plate in the treatment of pilon fractures. Retrospective case series. A tertiary referral center. Seventeen patients were treated between 1999 and 2001 for a tibial plafond fracture at the Hospital for Special Surgery with a newly designed low-profile plate. Eleven of the fractures (65%) were high-energy injuries. Two fractures were open. Staged surgical treatment with open reduction and fixation of the fibular fracture and application of an external fixator was performed in 12 cases. As soon as the soft tissues and swelling allowed, i.e. skin wrinkling, the articular surface was reconstructed and simply reduced, if necessary through an small incision, and the articular block was fixed to the diaphysis using a medially placed, percutaneously introduced flat scallop plate. In the remaining five cases the operation was performed in one session. Time to healing and complications including delayed union, non-union, instrument failure, loss of fixation, infection, quality of reduction and number of reoperations were evaluated. Quality of results and outcome were graded using the ankle-hindfoot-scale and a modified rating system. All patients went on to bony union at an average time of 14 weeks. There were no plate failures or loss of fixation/reduction. Two superficial wound-healing problems resolved with local wound care. At an average follow up of 17 months (range 6-29 months) eight patients (47%) had an excellent result; seven (41%) had a fair result whereas two (12%) had a poor result. The average ankle-hindfoot-score was 86.1 (range 61-100). Four patients have had the hardware removed and one of them is awaiting an ankle arthrodesis. Based on these initial results, it appears that a minimally invasive surgical technique including new low profile plate can decrease soft tissue problems while leading to fracture healing and obtaining results comparable with other more recent series. We believe that this new "Scallop Plate" is effective for the treatment of pilon fractures and should be used in conjunction with a staged procedure in the acute trauma setting.

  6. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    PubMed Central

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  7. Modified Judet approach and minifragment fixation of scapular body and glenoid neck fractures.

    PubMed

    Jones, Clifford B; Cornelius, Jonathan P; Sietsema, Debra L; Ringler, James R; Endres, Terrence J

    2009-09-01

    To describe the technique and to determine the outcome of operatively treated displaced scapular body or glenoid neck fractures using minifragment fixation through a modified Judet approach. Retrospective review of scapular or glenoid fractures. Level 1 teaching trauma center. All treated scapular or glenoid fractures over 7 years (1999-2005) were determined. Of a total of 227 scapular or glenoid fractures, 37 were treated with open reduction internal fixation and formed the basis of study. All patients were followed for a minimum of 1 year until healing or discharge from care. All operatively treated scapular fractures were performed in the lateral position on a radiolucent table. A modified Judet approach was used in all patients. The posterior deltoid was incised off the scapular spine cephalad reaching the lateral scapular border. The interval between the teres minor and infraspinatus was paramount for fracture reduction and implant insertion. The 2.7-mm minifragment plates were applied along the lateral border of the scapula. Radiographic assessment of fracture healing and clinical assessment of shoulder function. The majority of patients were males (31 males, 6 females) who sustained blunt trauma. All scapular fractures maintained fixation and reduction. No wound or muscle dehiscence problems were noted. Average range of motion was 158 degrees (range 90-180 degrees). There were no fixation failures or instances of implant loosening. The modified Judet approach allows for excellent scapular and glenoid fracture visualization and reduction while preserving rotator cuff function. Minifragment fixation along the lateral scapular border provides excellent plate position, screw length, and fracture stability.

  8. Sustained efficacy and safety of bazedoxifene in preventing fractures in postmenopausal women with osteoporosis: results of a 5-year, randomized, placebo-controlled study.

    PubMed

    Silverman, S L; Chines, A A; Kendler, D L; Kung, A W C; Teglbjærg, C S; Felsenberg, D; Mairon, N; Constantine, G D; Adachi, J D

    2012-01-01

    In this 2-year extension of a 3-year study, bazedoxifene showed sustained efficacy in preventing new vertebral fractures in postmenopausal women with osteoporosis and in preventing non-vertebral fractures in higher-risk women. Bazedoxifene significantly increased bone mineral density and reduced bone turnover versus placebo and was generally safe and well tolerated. This study evaluated the efficacy and safety of bazedoxifene for the treatment of postmenopausal osteoporosis over 5 years. A total of 4,216 postmenopausal women with osteoporosis were enrolled in this 2-year extension of a 3-year, randomized, double-blind, placebo-controlled, phase 3 trial. In the core study (N = 7,492), subjects received bazedoxifene 20 or 40 mg/day, raloxifene 60 mg/day, or placebo. The raloxifene arm was discontinued after 3 years; subjects receiving bazedoxifene 40 mg were transitioned to bazedoxifene 20 mg after 4 years. Five-year findings are reported for bazedoxifene 20 and 40/20 mg and placebo. Endpoints included incidence of new vertebral fractures (primary) and non-vertebral fractures, and changes in bone mineral density (BMD) and bone turnover markers. At 5 years, the incidence of new vertebral fractures in the intent-to-treat population was significantly lower with bazedoxifene 20 mg (4.5%) and 40/20 mg (3.9%) versus placebo (6.8%; P < 0.05), with relative risk reductions of 35% and 40%, respectively. Non-vertebral fracture incidence was similar among groups. In a subgroup of higher-risk women (n = 1,324; femoral neck T-score ≤-3.0 and/or ≥ 1 moderate or severe or ≥ 2 mild vertebral fracture[s]), bazedoxifene 20 mg reduced non-vertebral fracture risk versus placebo (37%; P = 0.06); combined data for bazedoxifene 20 and 40/20 mg reached statistical significance (34% reduction; P < 0.05). Bazedoxifene significantly increased BMD and reduced bone turnover versus placebo (P < 0.05) and was generally safe and well tolerated. The findings support a sustained anti-fracture effect of bazedoxifene on new vertebral fractures in postmenopausal osteoporotic women and on non-vertebral fractures in the higher-risk subgroup of women.

  9. Managing Osteoporosis Patients after Long-Term Bisphosphonate Treatment

    PubMed Central

    Adler, Robert A.; Fuleihan, Ghada El-Hajj; Bauer, Douglas C.; Camacho, Pauline M.; Clarke, Bart L.; Clines, Gregory A.; Compston, Juliet E.; Drake, Matthew T.; Edwards, Beatrice J.; Favus, Murray J.; Greenspan, Susan L.; McKinney, Ross; Pignolo, Robert J.; Sellmeyer, Deborah E.

    2016-01-01

    Bisphosphonates (BPs) are the most commonly used medications for osteoporosis, but optimal duration of therapy is unknown. This ASBMR report provides guidance on BP therapy duration with a risk benefit perspective. Two trials provided evidence for long-term BP use. In the Fracture Intervention Trial Long-term Extension (FLEX), postmenopausal women receiving alendronate for 10 years had fewer clinical vertebral fractures than those switched to placebo after 5 years. In the HORIZON extension, women who received 6 annual infusions of zoledronic acid had fewer morphometric vertebral fractures compared with those switched to placebo after 3 years. Low hip T-score between −2 and −2.5 in FLEX and below −2.5 in HORIZON extension predicted a beneficial response to continued therapy. Hence, the Task Force suggests that after 5 years of oral BP or 3 years of intravenous BP, women should be reassessed. Women with previous major osteoporotic fracture, those who fracture on therapy, or others at high risk should generally continue therapy for up to 10 years (oral) or 6 years (intravenous), with periodic risk-benefit evaluation. Older women, those with a low hip T-score or high fracture risk score are considered high risk. The risk of osteonecrosis of the jaw and atypical femoral fracture increases with BP therapy duration, but such rare events are far outweighed by fracture risk reduction with BPs in high risk patients. For women not at high fracture risk after 3–5 years of BP treatment, a drug holiday of 2–3 years can be considered, with periodic reassessment. The algorithm provided for long term BP use is based on limited evidence in mostly Caucasian postmenopausal women and only for vertebral fracture reduction. It is probably applicable to men and patients with glucocorticoid-induced osteoporosis, with some adaptations. It is unlikely that future osteoporosis trials will provide data for formulating definitive recommendations. PMID:26350171

  10. Effects of dose reduction on bone strength prediction using finite element analysis

    NASA Astrophysics Data System (ADS)

    Anitha, D.; Subburaj, Karupppasamy; Mei, Kai; Kopp, Felix K.; Foehr, Peter; Noel, Peter B.; Kirschke, Jan S.; Baum, Thomas

    2016-12-01

    This study aimed to evaluate the effect of dose reduction, by means of tube exposure reduction, on bone strength prediction from finite-element (FE) analysis. Fresh thoracic mid-vertebrae specimens (n = 11) were imaged, using multi-detector computed tomography (MDCT), at different intensities of X-ray tube exposures (80, 150, 220 and 500 mAs). Bone mineral density (BMD) was estimated from the mid-slice of each specimen from MDCT images. Differences in image quality and geometry of each specimen were measured. FE analysis was performed on all specimens to predict fracture load. Paired t-tests were used to compare the results obtained, using the highest CT dose (500 mAs) as reference. Dose reduction had no significant impact on FE-predicted fracture loads, with significant correlations obtained with reference to 500 mAs, for 80 mAs (R2  = 0.997, p < 0.001), 150 mAs (R2 = 0.998, p < 0.001) and 220 mAs (R2 = 0.987, p < 0.001). There were no significant differences in volume quantification between the different doses examined. CT imaging radiation dose could be reduced substantially to 64% with no impact on strength estimates obtained from FE analysis. Reduced CT dose will enable early diagnosis and advanced monitoring of osteoporosis and associated fracture risk.

  11. [Conservative treatment of metacarpal fracture].

    PubMed

    Prokop, A; Helling, H J; Kulus, S; Rehm, K E

    2002-01-01

    Conservative treatment of meatacarpale fracture is recommended if there are no joint displacement, rotation failures, displacement over 30 degrees ad axim and shortening over 5 mm. Operative procedures should be done in open fractures and serial of fractures of metacarpale bones. Early functionally treatment should be done in stable, not displaced fractures. Cast can be used only for a short time in full extended position of fingers and flexion in metacarpo-phalangeal joint in 60-90 degrees. Twin-tapes after reduction of edema allowed free range of motion by fixed rotation. Closed reduction of displaced fractures of fifth metacarpal bone (boxer's fracture) isn't successful. Cases with displacement over 30 degrees may be operatively treated by intramedullary stabilization.

  12. Anterior cervical distraction and screw elevating–pulling reduction for traumatic cervical spine fractures and dislocations

    PubMed Central

    Li, Haoxi; Yong, Zhiyao; Chen, Zhaoxiong; Huang, Yufeng; Lin, Zhoudan; Wu, Desheng

    2017-01-01

    Abstract Treatment of cervical fracture and dislocation by improving the anterior cervical technique. Anterior cervical approach has been extensively used in treating cervical spine fractures and dislocations. However, when this approach is used in the treatment of locked facet joints, an unsatisfactory intraoperative reduction and prying reduction increases the risk of secondary spinal cord injury. Thus, herein, the cervical anterior approach was improved. With distractor and screw elevation therapy during surgery, the restoration rate is increased, and secondary injury to the spinal cord is avoided. To discuss the feasibility of the surgical method of treating traumatic cervical spine fractures and dislocations and the clinical application. This retrospective study included the duration of patients’ hospitalization from January 2005 to June 2015. The potential risks of surgery (including death and other surgical complications) were explained clearly, and written consents were obtained from all patients before surgery. The study was conducted on 86 patients (54 males and 32 females, average age of 40.1 ± 5.6 years) with traumatic cervical spine fractures and dislocations, who underwent one-stage anterior approach treatment. The effective methods were evaluated by postoperative follow-up. The healing of the surgical incision was monitored in 86 patients. The follow-up duration was 18 to 36 (average 26.4 ± 7.1) months. The patients achieved bones grafted fusion and restored spine stability in 3 to 9 (average 6) months after the surgery. Statistically, significant improvement was observed by Frankel score, visual analog scale score, Japanese Orthopedic Association score, and correction rate of the cervical spine dislocation pre- and postoperative (P < .01). The modified anterior cervical approach is simple with a low risk but a good effect in reduction. In addition, it can reduce the risk of iatrogenic secondary spinal cord injury and maintain optimal cervical spine stability as observed during follow-ups. Therefore, it is suitable for clinical promotion and application. PMID:28658125

  13. The influence of third molars in the line of mandibular angle fractures on wound and bone healing.

    PubMed

    Ulbrich, N; Ettl, T; Waiss, W; Gosau, M; Moralis, A; Reichert, T E; Mueller, S

    2016-07-01

    The objective of this study was to evaluate postoperative complications after removal or retention of the third molar in the line of mandibular angle fractures. This retrospective study included the data of 98 patients with a molar in the line of a mandibular angle fracture treated with internal reduction and mini-plate fixation at our department over 9 years. Patients were classified into two groups: tooth removal during osteosynthesis (n = 45) and tooth retention (n = 55). The primary target criterion was the incidence of minor (outpatient treatment, local measures) and major (surgical revision, rehospitalisation) complications. Time between trauma and surgery was 1.4 days (range 0 to 12), and the average follow-up 291 days (range 66 to 863). Regarding the eruption status, 26 of 52 (50.0 %) impacted third molars, 11 of 19 (57.9 %) incompletely erupted and 8 of 27 (29.6 %) completely erupted molars had been removed during open reduction. Overall, 17 (17.3 %) patients had postoperative minor (n = 7) or major (n = 10) complications, in detail 10/45 (22.0 %) patients after tooth removal and 7/55 (13 %) patients after tooth retention (p = 0.286). Complication rates between impacted and incompletely erupted third molars (impacted molars 15.0 %, incompletely erupted molars 10.0 %) did not differ significantly, but completely erupted molars had a complication rate of 26.0 %. Mandibular angle fractures with a completely erupted third molar show the highest complication rate after open reduction and osteosynthesis. Retention of a non-infectious third molar facilitates open reduction and does not increase the complication risk. The study helps with the decision of removing or retention of a third molar during surgical treatment of a mandibular angle fracture.

  14. [Application of lateral malleolus hook-plate in treatment of stage II supination-adduction type medial malleolus fracture].

    PubMed

    Chen, Yu; Zhang, Hui; Huang, Fuguo; Xiang, Zhuo; Fang, Yue; Liu, Lei; Cen, Shiqiang

    2014-09-01

    To investigate the application of lateral malleolus hook-plate for the treatment of stage II supination-adduction type medial malleolus fractures. Between January 2011 and June 2013, 21 patients with stage II supination-adduction type ankle fractures were treated with lateral malleolus hook-plate, including 12 males and 9 females with an average age of 55.5 years (range, 27-65 years). The injury causes were sprain in 17 cases and traffic accident in 4 cases. The mean time between injury and admission was 12.4 hours (range, 2-72 hours). The tibial distal medial articular surface collapse was found in 7 cases by CT examination and in 3 cases by X-ray film. Of 21 cases, there were 12 cases of low transverse fractures of lateral malleolus, 7 cases of short oblique fractures of lateral malleolus, and 2 cases of ankle joint lateral collateral ligament injury without fractures of lateral malleolus. After operation, the clinical outcome was evaluated according to the talus-leg angle, the recovery of Coin-sign continuity, inside-outside and top ankle gap, talus slope, American Orthopedic Foot and Ankle Society (AOFAS) score, Olerud-Molander score, Kofoed evaluation standards, and patient satisfaction. Seventeen cases were followed up 18.7 months on average (range, 12-25 months). Primary healing was obtained in 16 cases except 1 case of delayed healing. Fracture healed at an average of 14.6 weeks (range, 12-16 weeks). All cases achieved anatomical reduction, the continuity of Coin-sign, and consistency of inside and outside joint gap; no talus tilt occurred. There was no complication of reduction loss, loosening or breakage of internal fixation, or osteoarthritis during follow-up. The talus-leg angle of the affected side was significantly improved to (83.4 ± 1.8)° at 1 week after operation from preoperative (74.8 ± 7.1)° (t = 5.370, P = 0.000), but no significant difference was found when compared with normal side (83.8 ± 2.3)° (t = 0.676, P = 0.509). The AOFAS score, Olerud-Molander score, and range of motion at 1 week, 3 months, and 1 year after operation were significantly improved when compared with preoperative ones (P < 0.05). According to Kofoed evaluation standard, the outcome was excellent in 15 cases and good in 2 cases; the excellent and good rate was 100%. According to patient satisfaction, the outcome was excellent in 13 cases, good in 3 cases, and poor in 1 case; the excellent and good rate was 94.1%. The use of lateral malleolus hook-plate for fixation of stage II supination-adduction type medial malleolus fracture not only can effectively maintain anatomical reduction and supporting function, but also can prevent re-collapsing of the reset joint surface. The surgical method can not increase soft tissue complication, so it is a safe and effective method.

  15. Treatment of displaced talar neck fractures using delayed procedures of plate fixation through dual approaches.

    PubMed

    Xue, Youdi; Zhang, Hui; Pei, Fuxing; Tu, Chongqi; Song, Yueming; Fang, Yue; Liu, Lei

    2014-01-01

    Treatment of talar neck fractures is challenging. Various surgical approaches and fixation methods have been documented. Clinical outcomes are often dissatisfying due to inadequate reduction and fixation with high rates of complications. Obtaining satisfactory clinical outcomes with minimum complications remains a hard task for orthopaedic surgeons. In the period from May 2007 to September 2010, a total of 31 cases with closed displaced talar neck fractures were treated surgically in our department. Injuries were classified according to the Hawkins classification modified by Canale and Kelly. Under general anaesthesia with sufficient muscle relaxation, urgent closed reduction was initiated once the patients were admitted; if the procedure failed, open reduction and provisional stabilisation with Kirschner wires through an anteromedial approach with tibiometatarsal external fixation were performed. When the soft tissue had recovered, definitive fixation was performed with plate and screws through dual approaches. The final follow-up examination included radiological analysis, clinical evaluation and functional outcomes which were carried out according to the Ankle-Hindfoot Scale of the American Orthopaedic Foot and Ankle Society (AOFAS), patient satisfaction and SF-36. Twenty-eight patients were followed up for an average of 25 months (range 18-50 months) after the injury. Only two patients had soft tissue complications, and recovery was satisfactory with conservative treatment. All of the fractures healed anatomically without malunion and nonunion, and the average union time was 14 weeks (range 12-24 weeks). Post-traumatic arthritis developed in ten cases, while six patients suffered from avascular necrosis of the talus. Secondary procedures included three cases of subtalar arthrodesis, one case of ankle arthrodesis and one case of total ankle replacement. The mean AOFAS hindfoot score was 78 (range 65-91). According to the SF-36, the average score of the physical component summary was 68 (range 59-81), and the average score of the mental component summary was 74 (range 63-85). Talar neck fractures are associated with a high incidence of long-term disability and complications. Urgent reduction of the fracture-dislocation and delayed plate fixation through a dual approach when the soft tissue has recovered may minimise the complications and provide good clinical outcomes.

  16. Status of the internal orbit after reduction of zygomaticomaxillary complex fractures.

    PubMed

    Ellis, Edward; Reddy, Likith

    2004-03-01

    We sought to determine the status of the internal orbit before and after reduction of zygomaticomaxillary complex (ZMC) fractures when treated without internal orbital reconstruction. We conducted a retrospective study of preoperative and postoperative computed tomography (CT) scans in 65 patients with unilateral ZMC fractures who were treated by reduction of the ZMC complex without internal orbital reconstruction. The size and location of the internal orbital defects, orbital soft tissue displacement, and orbital volume were assessed in the preoperative and postoperative CT scans. Reduction in the ZMC fractures was considered ideal in 58 of the 65 patients. Only minor malpositions occurred in the remaining 7 patients. The size of the internal orbital defects increased slightly with ZMC reduction but the internal orbital fractures were realigned, and few had increases in orbital volume or soft tissue sagging into the sinuses. Examination of follow-up CT scans in several patients taken weeks to months later showed that the residual defects became smaller and that none of these patients had an increase in orbital volume or soft tissue sagging. The preoperative CT scan can be used to assess the amount of internal orbital disruption for purposes of developing a treatment plan in patients with ZMC fractures. When there is minimal or no soft tissue herniation and minimal disruption of the internal orbit, ZMC reduction is adequate treatment.

  17. Surgical treatment of distal tibia fractures: open versus MIPO.

    PubMed

    Gülabi, Deniz; Bekler, Halil İbrahim; Sağlam, Fevzi; Taşdemir, Zeki; Çeçen, Gültekin Sıtkı; Elmalı, Nurzat

    2016-01-01

    Treatment of the distal tibial fractures are challenging due to the limited soft tissue, subcutaneous location and poor vascularity. In this control-matched study, it was aimed to compare the traditional open reduction and internal fixation with minimal invasive plating (MIPO). We hypothesized that superior results may be achieved with MIPO technique. 22 patients treated with traditional open reduction and internal fixation were matched with 22 patients treated with closed reduction and MIPO on the basis of age (±3), gender, and fracture pattern (AO classification). Evaluation was assed according to the wound problems, the American Orthopaedic Foot and Ankle surgery (AOFAS) scoring, radiological union, malunion, delayed union, hospitalisation time, time from injury to surgery, and operation time. There was no significant difference in the distribution of AO/OTA classification, age, gender, AOFAS score, time from injury to operation, follow-up, bone union time, delayed union, malunion and infection (p>0.05). The operation time was significantly longer in the open group than in the MIPO group: 69.59±7.21 min. for the ORIF, and 61.14±5.61 for the MIPO group (p<0.01).The hospitalisation time was significantly longer in the open group than in the MIPO group: 7.64±4.71 days for the MIPO, and 10.18±4.32 days for the ORIF group (p<0.05). MIPO technique can be beneficial for the treatment of distal tibia AO/OTA A and B type fractures with reduced hospital stay, cost-effectiveness, and infection rate.

  18. The Cost-Effectiveness of Surgical Fixation of Distal Radial Fractures: A Computer Model-Based Evaluation of Three Operative Modalities.

    PubMed

    Rajan, Prashant V; Qudsi, Rameez A; Dyer, George S M; Losina, Elena

    2018-02-07

    There is no consensus on the optimal fixation method for patients who require a surgical procedure for distal radial fractures. We used cost-effectiveness analyses to determine which of 3 modalities offers the best value: closed reduction and percutaneous pinning, open reduction and internal fixation, or external fixation. We developed a Markov model that projected short-term and long-term health benefits and costs in patients undergoing a surgical procedure for a distal radial fracture. Simulations began at the patient age of 50 years and were run over the patient's lifetime. The analysis was conducted from health-care payer and societal perspectives. We estimated transition probabilities and quality-of-life values from the literature and determined costs from Medicare reimbursement schedules in 2016 U.S. dollars. Suboptimal postoperative outcomes were determined by rates of reduction loss (4% for closed reduction and percutaneous pinning, 1% for open reduction and internal fixation, and 11% for external fixation) and rates of orthopaedic complications. Procedural costs were $7,638 for closed reduction and percutaneous pinning, $10,170 for open reduction and internal fixation, and $9,886 for external fixation. Outputs were total costs and quality-adjusted life-years (QALYs), discounted at 3% per year. We considered willingness-to-pay thresholds of $50,000 and $100,000. We conducted deterministic and probabilistic sensitivity analyses to evaluate the impact of data uncertainty. From the health-care payer perspective, closed reduction and percutaneous pinning dominated (i.e., produced greater QALYs at lower costs than) open reduction and internal fixation and dominated external fixation. From the societal perspective, the incremental cost-effectiveness ratio for closed reduction and percutaneous pinning compared with open reduction and internal fixation was $21,058 per QALY and external fixation was dominated. In probabilistic sensitivity analysis, open reduction and internal fixation was cost-effective roughly 50% of the time compared with roughly 45% for closed reduction and percutaneous pinning. When considering data uncertainty, there is only a 5% to 10% difference in the frequency of probability combinations that find open reduction and internal fixation to be more cost-effective. The current degree of uncertainty in the data produces difficulty in distinguishing either strategy as being more cost-effective overall and thus it may be left to surgeon and patient shared decision-making. Economic Level III. See Instructions for Authors for a complete description of levels of evidence.

  19. Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation.

    PubMed

    Prasarn, Mark L; Meyers, Kathleen N; Wilkin, Geoffrey; Wellman, David S; Chan, Daniel B; Ahn, Jaimo; Lorich, Dean G; Helfet, David L

    2015-12-01

    We sought to evaluate clinical and biomechanical outcomes of dual mini-fragment plate fixation for clavicle fractures. We hypothesized that this technique would produce an anatomical reduction with good clinical outcomes, be well tolerated by patients, and demonstrate equivalent biomechanics to single plating. Dual mini-fragment plating was performed for 17 isolated, displaced midshaft clavicle fractures. Functional outcomes and complications were retrospectively reviewed. A sawbones model compared dual plating biomechanics to a (1) superior 3.5-mm locking reconstruction plate, or (2) antero-inferior 3.5-mm locking reconstruction plate. On biomechanical testing, with anterior loading, dual plating was significantly more rigid than single locked anterior-plating (p = 0.02) but less rigid than single locked superior-plating (p = 0.001). With superior loading, dual plating trended toward higher rigidity versus single locked superior-plating (p = 0.07) but was less rigid than single locked anterior-plating (p = 0.03). No statistically significant differences in axial loading (p = 0.27) or torsion (p = 0.23) were detected. Average patient follow-up was 16.1 months (12-38). Anatomic reduction was achieved and maintained through final healing (average 14.7 weeks). No patient underwent hardware removal. Average 1-year DASH score was 4.0 (completed in 88 %). Displaced midshaft clavicle fractures can be effectively managed with dual mini-fragment plating. This technique results in high union rates and excellent clinical outcomes. Compared to single plating, dual plating is biomechanically equivalent in axial loading and torsion, yet offers better multi-planar bending stiffness despite the use of smaller plates. This technique may decrease the need for secondary surgery due to implant prominence and may aid in fracture reduction by buttressing butterfly fragments in two planes.

  20. The limited anterior approach of the elbow for open reduction and internal fixation of capitellum fractures. Surgical technique and clinical experience in 2 cases with more than 2 years follow-up.

    PubMed

    Ballesteros-Betancourt, J R; Fernández-Valencia, J A; García-Tarriño, R; Domingo-Trepat, A; Sastre-Solsona, S; Combalia-Aleu, A; Llusá-Pérez, M

    Fractures involving the capitellum can be treated surgically by excision of the fragment, or by reduction and internal fixation with screws, with or without heads. The lateral Kocher approach is the most common approach for open reduction. We believe that the limited anterior approach of the elbow, could be a valid technique for treating these fractures, as it does not involve the detachment of any muscle group or ligament, facilitating the recovery process. A description is presented of the surgical technique, as well as of 2cases with a Bryan-Morrey type 1 fracture (Dubberley type 1A). Two different final quality of life evaluation questionnaires were completed by telephone: the EuroQol Five Dimensions Questionnaire (EQ-5D), and the patient part of the Liverpool Elbow Score (PAQ-LES) questionnaire. The 2patients showed favourable clinical progress at 36 and 24 months, respectively, with an extension/flexion movement arc of -5°/145° and -10°/145°, as well as a pronosupination of 85°/80° and 90°/90°. The 2patients showed radiological consolidation with no signs of osteonecrosis. The EQ-5D score was 0.857 and 0.910 (range: 0.36-1), and a PAQ-SLE of 35 and 35 (range: 17-36), respectively. We believe that the limited anterior approach of the elbow is a technical option to consider for the open surgical treatment of a capitellum fracture, although further studies are needed to demonstrate its superiority and clinical safety compared to the classical lateral Kocher approach. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Outcome of Surgical Fixation of Lateral Column Distal Humerus Fractures.

    PubMed

    Von Keudell, Arvind; Kachooei, Amir R; Moradi, Ali; Jupiter, Jesse B

    2016-05-01

    The purpose of this study was to report the long-term outcome and complications of surgically fixated lateral unicondylar distal humerus fractures. Retrospective Review. Two level 1 Trauma Centers, Massachusetts General Hospital and Brigham and Women's Hospital. Between 2002 and 2014, 24 patients treated with open reduction and internal fixation for lateral unicondylar distal humerus fractures (OTA/AO type B1 fractures) were retrospectively reviewed. Open reduction and internal fixation. Union rates, early complications, functional outcome, and the range of elbow motion were evaluated. Disabilities of the arm, shoulder, and hand, Mayo elbow Performance Index, satisfaction, pain scale, and American Shoulder and Elbow Surgeons. The mean age of patients was 46 ± 23 years at the time of surgery. The average final flexion/extension arc of motion was 108°. Reoperations were performed in 9 of 24 elbows after an average 21 ± 31 months. Twenty of the 24 patients were available for the clinical follow-up at an average of 70 months (range: 16-144 months). Disabilities of the arm, shoulder, and hand averaged at 10.8 ± 11.7 points, satisfaction at 9.5 ± 1.2, American Shoulder and Elbow Surgeons score at 88.5 ± 13.3 points at final follow-up. Based on the functional classification proposed by Jupiter, 16 demonstrated good to excellent results, 2 fair and 2 poor result. Outcome of open reduction and internal fixation of isolated lateral column distal humerus fractures can result in high union rates with acceptable outcome scores and high patient satisfaction despite a high reoperation rate. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  2. A visual servo-based teleoperation robot system for closed diaphyseal fracture reduction.

    PubMed

    Li, Changsheng; Wang, Tianmiao; Hu, Lei; Zhang, Lihai; Du, Hailong; Zhao, Lu; Wang, Lifeng; Tang, Peifu

    2015-09-01

    Common fracture treatments include open reduction and intramedullary nailing technology. However, these methods have disadvantages such as intraoperative X-ray radiation, delayed union or nonunion and postoperative rotation. Robots provide a novel solution to the aforementioned problems while posing new challenges. Against this scientific background, we develop a visual servo-based teleoperation robot system. In this article, we present a robot system, analyze the visual servo-based control system in detail and develop path planning for fracture reduction, inverse kinematics, and output forces of the reduction mechanism. A series of experimental tests is conducted on a bone model and an animal bone. The experimental results demonstrate the feasibility of the robot system. The robot system uses preoperative computed tomography data to realize high precision and perform minimally invasive teleoperation for fracture reduction via the visual servo-based control system while protecting surgeons from radiation. © IMechE 2015.

  3. Outcome of bone marrow instillation at fracture site in intracapsular fracture of femoral neck treated by head preserving surgery.

    PubMed

    Verma, Nikhil; Singh, M P; Ul-Haq, Rehan; Rajnish, Rajesh K; Anshuman, Rahul

    2017-08-01

    The aim of present study is to evaluate the outcome of bone marrow instillation at the fracture site in fracture of intracapsular neck femur treated by head preserving surgery. This study included 32 patients of age group 18-50 years with closed fracture of intracapsular neck femur. Patients were randomized into two groups as per the plan generated via www.randomization.com. The two groups were Group A (control), in which the fracture of intracapsular neck femur was treated by closed reduction and cannulated cancellous screw fixation, and Group B (intervention), in which additional percutaneous autologous bone marrow aspirate instillation at fracture site was done along with cannulated cancellous screw fixation. Postoperatively the union at fracture site and avascular necrosis of the femoral head were assessed on serial plain radiographs at final follow-up. Functional outcome was evaluated by Harris hip score. The average follow-up was 19.6 months. Twelve patients in each group had union and 4 patients had signs of nonunion. One patient from each group had avascular necrosis of the femoral head. The average Harris hip score at final follow-up in Group A was 80.50 and in Group B was 75.73, which was found to be not significant. There is no significant role of adding on bone marrow aspirate instillation at the fracture site in cases of fresh fracture of intracapsular neck femur treated by head preserving surgery in terms of accelerating the bone healing and reducing the incidence of femoral head necrosis. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  4. Arthroscopic evaluation of soft tissue injuries in tibial plateau fractures: retrospective analysis of 98 cases.

    PubMed

    Abdel-Hamid, Mohamed Zaki; Chang, Chung-Hsun; Chan, Yi-Sheng; Lo, Yang-Pin; Huang, Jau-Wen; Hsu, Kuo-Yao; Wang, Ching-Jen

    2006-06-01

    This investigation arthroscopically assesses the frequency of soft tissue injury in tibial plateau fracture according to the severity of fracture patterns. We hypothesized that use of arthroscopy to evaluate soft tissue injury in tibial plateau fractures would reveal a greater number of associated injuries than have previously been reported. From March 1996 to December 2003, 98 patients with closed tibial plateau fractures were treated with arthroscopically assisted reduction and osteosynthesis, with precise diagnosis and management of associated soft tissue injuries. Arthroscopic findings for associated soft tissue injuries were recorded, and the relationship between fracture type and soft tissue injury was then analyzed. The frequency of associated soft tissue injury in this series was 71% (70 of 98). The menisci were injured in 57% of subjects (56 in 98), the anterior cruciate ligament (ACL) in 25% (24 of 98), the posterior cruciate ligament (PCL) in 5% (5 of 98), the lateral collateral ligament (LCL) in 3% (3 of 98), the medial collateral ligament (MCL) in 3% (3 of 98), and the peroneal nerve in 1% (1 of 98); none of the 98 patients exhibited injury to the arteries. No significant association was noted between fracture type and incidence of meniscus, PCL, LCL, MCL, artery, and nerve injury. However, significantly higher injury rates for the ACL were observed in type IV and VI fractures. Soft tissue injury was associated with all types of tibial plateau fracture. Menisci (peripheral tear) and ACL (bony avulsion) were the most commonly injured sites. A variety of soft tissue injuries are common with tibial plateau fracture; these can be diagnosed with the use of an arthroscope. Level III, diagnostic study.

  5. Arthroscopic fixation of the clavicle shaft fracture.

    PubMed

    Kim, Yang-Soo; Lee, Hyo-Jin; Kim, Jong-Ick; Yang, Hyo; Jin, Hong-Ki; Patel, Hiren Kirtibhai; Kim, Jong-Ho; Park, In

    2017-01-01

    This article describes an arthroscopic technique for the fixation of clavicle shaft fractures. A viewing portal is made 2 cm anterior to the fracture site, and a working portal is made 2 cm lateral to the fracture site. The guide wire for a 4.0-mm cannulated screw is inserted through the fracture site to the medial fracture fragment under arthroscopic guidance. Through the medial fragment, the guide wire is delivered through the skin anteriorly. The fracture is reduced, and then, the guide wire is drilled back across the fracture site to the lateral fracture fragment. After confirming the reduction under arthroscopy, the appropriately sized cannulated screw is inserted after reaming. This arthroscopic technique would be useful for the precise reduction and minimal invasive fixation of clavicle shaft fractures. Preliminary results are encouraging, and further studies with long-term follow-up are needed to determine the precise indications and limitations of the procedure.

  6. A Technique for Reduction of Edentulous Fractures Using Dentures and SMARTLock Hybrid Fixation System

    PubMed Central

    Carlson, Anna Rose; Shammas, Ronnie Labib; Allori, Alexander Christopher

    2017-01-01

    Summary: Establishing anatomic reduction of an edentulous mandible fracture is a frequently acknowledged challenge in craniomaxillofacial trauma surgery. In this study, we report a novel method for the reduction of the edentulous mandible fracture, via fabrication of modified Gunning splints using existing dentures and SMARTLock hybrid arch bars. This technique dramatically simplifies the application of an arch bar to dentures, obviates the need for the fabrication of impressions and custom splints, and eliminates the lag time associated with the creation of splints. Furthermore, this method may be used with or without adjunctive rigid internal fixation. The technique described herein of creating Gunning splints with SMARTLock hybrid arch bars provides surgeons with a simple, rapid, single-stage solution for reduction of mandibular fractures in the edentulous patient. PMID:29062645

  7. High incidence of osteochondral lesions after open reduction and internal fixation of displaced ankle fractures: Medium-term follow-up of 100 cases.

    PubMed

    Regier, Marc; Petersen, Jan Philipp; Hamurcu, Ahmet; Vettorazzi, Eik; Behzadi, Cyrus; Hoffmann, Michael; Großterlinden, Lars G; Fensky, Florian; Klatte, Till Orla; Weiser, Lukas; Rueger, Johannes M; Spiro, Alexander S

    2016-03-01

    The incidence of osteochondral lesions (OCLs) in association with displaced ankle fractures has only been examined in two previous studies. In both studies magnetic resonance imaging (MRI) was performed prior to open reduction and internal fixation (ORIF). Because MRI may overdiagnose or overestimate the extent of OCLs in an acute trauma setting the aim of this study was to determine the incidence of OCLs after ORIF of displaced ankle fractures using MRI at medium-term follow-up, and to analyse if the severity of fracture or the clinical outcome correlates with the incidence of OCLs. Following institutional review board approval a total of 100 patients (mean age, 41.3 years; range, 17.9-64.3 years) with a displaced ankle fracture who had undergone ORIF according to the AO principles were included in this study. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score was used to quantify the clinical outcome and MR images were evaluated for OCLs of the talus and distal tibia after a mean of 34.5 months (range, 17.5-54.1 months). OCLs were found in 40.4% of the patients. Logistic regression revealed a significant correlation between the severity of fracture and the incidence of OCLs. Patients with a trimalleolar fracture (p=0.04) or an ankle fracture dislocation (p=0.003) had a significantly higher risk for developing an OCL compared to those with a type B fracture. Logistic regression also demonstrated a significant correlation between the clinical outcome (AOFAS score) and the incidence of OCLs (p=0.01). The risk for developing an OCL increases up to 5.6% when the AOFAS score decreases by one point. OCLs were frequently found in association with acute ankle fractures at medium-term follow-up, and the severity of fracture was associated with an increased number of OCLs. Considering the disadvantages of MRI including the high cost and limited availability, the results of this study may help to explain why anatomic surgical realignment of displaced ankle fractures may still be associated with poor clinical outcomes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. [The randomized controlled trial of the treatment for clavicular fracture by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation].

    PubMed

    Bi, Hong-zheng; Yang, Mao-qing; Tan, Yuan-chao; Fu, Song

    2008-07-01

    To study the curative effect and safety of rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation in treating clavicular fracture. All 201 cases of clavicular fractures were randomly divided into treatment group (101 cases) and control group (100 cases). The treatment group was treated by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation. The control group was treated by open reduction and internal fixation with Kirschner pin. All cases were followed up for 4 to 21 months (mean 10.6 months). SPSS was used to analyze clinic healing time of fracture and shoulder-joint function in both two groups. After operation, 101 cases of treatment group achieved union of fracture and the clinical healing time was 28 to 49 days (mean 34.5+/-2.7 days). In control group,there were 4 cases with nonunion of fracture,the other 96 cases were union,the clinical healing time was 36 to 92 days (mean 55.3+/-4.8 days). The excellent and good rate of shoulder-joint function was 100% in treatment group and 83% in control group. By t-test and chi2-test, there was significant difference between the two groups in curative effect (P<0.05). Rotatory manual reduction with forceps holder and retrograde pinning transfixation can be used in various kinds of clavicular shaft fracture, with many virtues such as easy operation, reliable fixation, short union time of fracture, good functional recovery of shoulder-joint and no incision scar affecting appearance.

  9. Persistence, adherence, and medication-taking behavior in women with postmenopausal osteoporosis receiving denosumab in routine practice in Germany, Austria, Greece, and Belgium: 12-month results from a European non-interventional study.

    PubMed

    Hadji, P; Papaioannou, N; Gielen, E; Feudjo Tepie, M; Zhang, E; Frieling, I; Geusens, P; Makras, P; Resch, H; Möller, G; Kalouche-Khalil, L; Fahrleitner-Pammer, A

    2015-10-01

    Persistence with and adherence to osteoporosis therapy are critical for fracture reduction. This non-interventional study is evaluating medication-taking behavior of women with postmenopausal osteoporosis (PMO) receiving denosumab in Germany, Austria, Greece, and Belgium. Patients were representative of the PMO population and highly persistent with and adherent to denosumab at 12 months. Persistence with and adherence to osteoporosis therapy are important for optimal treatment efficacy, namely fracture reduction. This ongoing, non-interventional study will evaluate medication-taking behavior of women with postmenopausal osteoporosis (PMO) receiving denosumab in routine practice in four European countries. The study enrolled women who had been prescribed subcutaneous denosumab (60 mg every 6 months) in accordance with prescribing information and local guidelines. Persistence was defined as receiving the subsequent injection within 6 months + 8 weeks of the previous injection. Adherence was defined as receiving two consecutive injections within 6 months ± 4 weeks of each other. Medication coverage ratio (MCR) was calculated using the time a patient was covered with denosumab, as assessed from prescription records. Treatment was assigned prior to and independently of enrollment; outcomes are recorded during routine practice. These planned 12-month interim analyses included data from 1500 patients from 141 sites. Mean age was 66.4-72.4 years, mean baseline total hip T-scores ranged from -2.0 to -2.1 and femoral neck T-scores from -2.2 to -2.6, and 30.7-62.1% of patients had prior osteoporotic fracture. Persistence was 87.0-95.3%, adherence 82.7-89.3%, and MCR 91.3-95.4%. In a univariate analysis, increased age, decreased mobility, and increased distance to the clinic were associated with significantly decreased persistence; parental history of hip fracture was associated with significantly increased persistence. These data extend the real-world evidence regarding persistence with and adherence to denosumab, both of which are critical for favorable clinical outcomes, including fracture risk reduction.

  10. Emergency ultrasound in the detection of pediatric long-bone fractures.

    PubMed

    Barata, Isabel; Spencer, Robert; Suppiah, Ara; Raio, Christopher; Ward, Mary Frances; Sama, Andrew

    2012-11-01

    Long-bone fractures represent one of the most commonly sustained injuries following trauma and account for nearly 4% of emergency department visits in the United States each year. These fractures are associated with a significant risk of bleeding and neurovascular compromise. Delays in their identification and treatment can lead to loss of limb and even death. Although emergency physicians currently rely predominantly on radiography for the examination of long-bone injuries, emergency ultrasound has several advantages over radiography and may be useful in the identification of long-bone fractures. Ultrasound is rapid, noninvasive, and cost-effective. Unlike radiography, ultrasound does not expose children to ionizing radiation, which has been linked to cancer. The goal of this study was to assess the agreement between emergency physicians' and radiologists' final assessments of suspected long-bone fractures using emergency ultrasound and radiography, respectively, in the pediatric population. This is a prospective study involving a convenience sample of pediatric patients (<18 years of age) who presented to the emergency department of a university-affiliated, level I trauma center between March 2008 and January 2009 with at least 1 suspected long-bone fracture. Suspected fractures were characterized by swelling, erythema, and localized pain. Patients who had a history of fracture, extremity deformity, orthopedic hardware in the traumatized area, or an open fracture were excluded from this study. Each investigator received limited, focused training in the use of ultrasonography for fracture identification and localization. This training consisted of a brief didactic session and video review of normal and fractured long-bones. A total of 53 subjects (mean age, 10.2 [SD, 3.8] years; 56.6% were male) were enrolled, which corresponded to 98 ultrasound examinations. Sixty-nine scans (70.4%) involved bones of the upper extremity, and 29 (29.6%) the lower extremity. Radiography identified a total of 43 fractures. The sensitivity and specificity of ultrasound in the detection of long-bone fractures were 95.3% (95% confidence interval [CI], 82.9%-99.2%) and 85.5% (95% CI, 72.8%-93.1%), respectively, and the positive and negative predictive values were 83.7% (95% CI, 68.8%-92.2%) and 96% (95% CI, 84.9%-99.3%), respectively. Overall, ultrasound detected 100.0% of diaphyseal fractures and 27 (93.1%) of 29 end-of-bone or near-joint fractures.Radiography revealed 6 displacements that met the published criteria for reduction, all of which were also revealed by ultrasound. The overall sensitivity and specificity for ultrasound identifying the need for reduction were 100.0% (95% CI, 51.7%-100.0%) and 97.3% (95% CI, 84.2%-99.9%), respectively, and positive and negative predictive values were 85.7% (95% CI, 42.0%-99.2%) and 100.0% (95% CI, 88.0%-100.0%), respectively. Emergency department physician-performed focused ultrasound was more accurate in detecting diaphyseal fractures than in detecting fractures in the metaphysis and/or epiphysis. The high sensitivity and specificity of ultrasound in the detection of long-bone fractures and the need for reduction support the use of ultrasound in the evaluation of suspected long-bone fractures in children.

  11. Changing pattern and etiology of maxillofacial fractures during the civil uprising in Western Libya

    PubMed Central

    Elarabi, Mohammed S.

    2018-01-01

    Background The purpose of the present study was to evaluate changing pattern in characteristics of maxillofacial fractures and concomitant injuries in Western Libya During revolution and to assess the association between mechanism of injury and fracture patterns. Material and Methods A retrospective review of medical records and radiographs of 187 patients treated for maxillofacial fractures from January 2010 to December 2012 was performed, there were 326 fractures in 187 patients. Results The male: female ratio was 6:1. Most fractures occurred in patients aged 11 to 40 years, and few injuries occurred in patients aged > 50 years. Most fractures occurred from motor vehicle accidents, and other most frequent causes included assault, gunshot, and fall injuries. Most maxillofacial fractures involved the mandible, zygomatic complex, or maxilla. Most mandibular fractures occurred at the parasymphysis, angle, or condyle. Associated injuries most frequently involved the head, chest, and extremities. Most patients were treated with open reduction (132 patients [71%]), and 26 patients (14%) were treated nonoperatively. There were 21 complications (11%). Conclusions In summary, motor vehicle accidents were the most frequent cause of maxillofacial fracture in western Libya, possibly because of the lack of seat belt legislation. Interpersonal violence was a less frequent cause of maxillofacial fracture, possibly because of the religious restriction on alcohol consumption. Key words:Tauma, mandible, zygomatic complex, maxilla, treatment, complications. PMID:29476683

  12. Percutaneous reduction and fixation of an intra-articular calcaneal fracture using an inflatable bone tamp: description of a novel and safe technique

    PubMed Central

    2012-01-01

    Calcaneal fractures are common injuries involving the hind foot and often a source of significant long-term morbidity. Treatment options have changed throughout the ages from periods of preferred nonoperative management to closed reduction with a mallet, and more recently, open reduction and anatomic internal fixation. The current treatment of choice; however, is often debated, as open management of these fractures carries many risks to include wound breakdown and infection. A less invasive form of surgical management through small incisions, while maintaining the ability to obtain joint congruency, anatomic alignment, and restore calcaneal height and width would be ideal. We propose a novel form of fracture reduction using an inflatable bone tamp and percutaneous fracture fixation. Preoperative planning and experienced fluoroscopy is crucial to successful management using this method. Although we achieved successful radiographic outcome in this case, long-term functional outcome of this technique are yet to be published. PMID:22420710

  13. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.

    PubMed

    Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven

    2010-05-01

    This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.

  14. How bone quality may influence intraoperative and early postoperative problems after angular stable open reduction-internal fixation of proximal humeral fractures.

    PubMed

    Spross, Christian; Zeledon, Rebeca; Zdravkovic, Vilijam; Jost, Bernhard

    2017-09-01

    With the introduction of the deltoid tuberosity index (DTI), a simple radiographic tool has become available to measure bone mineral density of the proximal humerus. The aim of this study was to assess the influence of local bone mineral density on the early failure rate after angular stable open reduction-internal fixation of proximal humeral fractures (PHFs). We retrospectively followed up all patients treated with angular stable implants for PHFs from 2007 to 2014. The fractures were classified according to Neer, and the DTI, metaphyseal head extension (MHE), medial hinge displacement, and quality of reduction were assessed. Failures were defined as head screw cutouts. The study included 146 patients (mean age, 66 years; range, 20-94 years). The mean follow-up period was 11 months (range, 3-94 months). Of the fractures, 91% were classified as 2- or 3-part fractures and 9% as 4-part fractures. The mean DTI was 1.44 (range, 1.19-2.11), and the mean MHE was 12 mm (range, 0-48 mm). The reduction result was at least acceptable in 80% of fractures. Screw cutouts were found in 23%. The DTI and MHE were the most significant preoperative predictors for the reduction result. The DTI (P = .036) and age (P = .02) were independent preoperative factors, and a good reduction (P = .001) was the only intraoperative factor influencing cutout. This study proves that good bone quality and a long MHE are helpful for the reduction. Furthermore, good bone quality, a younger age, and a good reduction prevent later cutout. We conclude that local bone quality is a relevant factor in the treatment plan for PHFs. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Facial trauma.

    PubMed

    Peeters, N; Lemkens, P; Leach, R; Gemels B; Schepers, S; Lemmens, W

    Facial trauma. Patients with facial trauma must be assessed in a systematic way so as to avoid missing any injury. Severe and disfiguring facial injuries can be distracting. However, clinicians must first focus on the basics of trauma care, following the Advanced Trauma Life Support (ATLS) system of care. Maxillofacial trauma occurs in a significant number of severely injured patients. Life- and sight-threatening injuries must be excluded during the primary and secondary surveys. Special attention must be paid to sight-threatening injuries in stabilized patients through early referral to an appropriate specialist or the early initiation of emergency care treatment. The gold standard for the radiographic evaluation of facial injuries is computed tomography (CT) imaging. Nasal fractures are the most frequent isolated facial fractures. Isolated nasal fractures are principally diagnosed through history and clinical examination. Closed reduction is the most frequently performed treatment for isolated nasal fractures, with a fractured nasal septum as a predictor of failure. Ear, nose and throat surgeons, maxillofacial surgeons and ophthalmologists must all develop an adequate treatment plan for patients with complex maxillofacial trauma.

  16. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    PubMed

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. [Management of displaced radial neck fractures in children: elastic stable intramedullary nailing vs K-wire fixation].

    PubMed

    Wu, Quan-Zhou; Huang, Shu-Ming; Cai, Qi-Xun; Chu, Xu-Feng

    2017-01-25

    To compare the complications and clinical outcome of titanium elastic nail(TEN) versus K-wire fixation(KW) for the treatment of displaced radial neck fractures in children. From January 2009 to December 2014, 56 children with displaced radial neck fractures were studied retrospectively according to the inclusion criteria. Based on the different methods of internal fixation, patients were divided into two groups: titanium elastic nail (TEN group) and K-wire fixation (KW group). Among 25 patients(15 males and 11 females, aged from 3 to 12 years old with an average of 8.6±2.1) treated with TEN, 16 patients had type III fractures, 19 patients had type IV fractures according to Metaizeau-Judet modified classification; 20 patients were treated with closed reduction and 5 patients were treated with open reduction; the time from injury to treatment ranged from 1 to 8 days with an average of (3.6±1.7) days. Among 31 patients (20 males and 11 females, aged from 3 to 11 years old with an average of 9.1±1.9 years old) treated with KW, 19 patients had type III fractures, 12 patients had type IV fractures; 22 patients were treated with closed reduction, and 9 patients were treated with open reduction; the time from injury to treatment ranged from 2 to 7 days with an average of (3.7±1.5) days. No significant differences between two groups were found in general data. Operative time, hospitalization time, healing time of fracture, internal fixation time, postoperative complications and function recovery of the two groups were compared and evaluated. The average follow-up period of the patients was 22.1 months in TEN group(ranged, 16 to 48 months), and 21.9 months in KW group(ranged, 13 to 48 months). There were no significant differences between these 2 groups in follow-up duration, average hospitalization time and fracture healing time. The operation time, hospital costs and internal fixation time in TEN group were (56.6±11.8) min, (18 000±3 000) Yuan(RMB), (9.1±2.5) weeks respectively; and in KW group were(45.5±10.3) min, (8 000±1 000) Yuan(RMB), (4.8±1.6) weeks respectively, there were significant differences between two groups( P <0.05). Outcome scores according to Metaizeau and Tibone-Stoltz had no significant differences between two groups( P >0.05). There is no significant difference of therapeutic effects between TEN and KW for children with displaced radial neck fractures. Because the removal of TEN fixation requires the secondary anesthesia, and the TEN costs significantly more than KW, TEN still can't replace the traditional KW for the treatment of radial neck fracture in children.

  18. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].

    PubMed

    Zeman, P; Zeman, J; Matejka, J; Koudela, K

    2008-12-01

    To report on the surgical treatment of intra-articular calcaneal fractures by open reduction and internal fixation with a calcaneal locking compression plate (LCP) from an extended lateral approach, and to retrospectively analyze the mid-term results in a group of patients treated by this technique. In the period from August 2005 till March 2007, a total of 49 patients with 61 calcaneal fractures were treated. Of these, 11 (18 %) were treated conservatively. Reduction combined with Kirschner-wire fixation was used in four fractures (6.6 %). Open reduction with internal calcaneal LCP fixation (ORIF- calcaneal LCP) from an extended lateral approach was carried out to treat 46 fractures (75.4 %) in 38 patients. The group evaluated here comprised 29 patients with 33 calcaneal fractures treated by ORIF-calcaneal LCP at a follow-up longer than 6 months. The fractures were classified on the basis of computer tomography (CT) findings as Sanders types I to IV. The group had two woman (6.9 %) and 27 men (93.1 %) with an average age of 34.2 years (range, 19-55 years). In 11 fractures (33.3 %), the primary treatment included filling a central cancellous bone defect area. Calcium phosphate bone substitute material (resorbable ChronOS) was used in nine cases (27.3 %), a self-solidifying hydroxyapatite implant was injected in two (6.1 %) cases (X3 Wright and Norian SRS, respectively), and a bone allograft was implanted in one case (3 %). Indicated for surgery were patients with an intra-articular calcaneal fracture, Sanders type II or type III, with articular surface displacement by more than 1 mm. Contraindications included age over sixty years, poor cooperation, smoking habits, peripheral vascular disease or skin infection. Surgery was performed only after oedema had resolved. The aim of our treatment was to achieve anatomical reconstruction of all articular surfaces, to restore the height, length, width and axis of the heel bone, to carry out primary stable osteosynthesis, and to enable the patient to begin rehabilitation with early mobilization. A passive rehabilitation usually started on the first post-operative day, and full weight-bearing of the extremity was allowed not earlier than 3 months post-operatively. Regular check-ups were at 6 weeks, 3, 6 and 12 months and then every year. The mid-term results were evaluated by the system of Rowe et al., scoring rest pain, possibility of return to preinjury jobs, use of walking aids, restriction of physical activity and limping. RESULTS The most frequent cause of injury was a fall or jump from height; this was recorded in 27 patients (93.1 %). An open fracture was diagnosed on two occasions (6.9 %). Bilateral calcaneal fractures were found in six patients (20.7 %); four (13.8 %) were treated by bilateral ORIF-calcaneal LPC and two (6.9 %) underwent closed reduction on one and Kirschnerwire transfixation on the other extremity. A combined injury to the musculoskeletal system was diagnosed in 11 patients (38 %), in whom four (13.8 %) had a tibial pylon fracture of the contralateral limb and four (13.8 %) had a thoracolumbar spine fracture. The surgical procedure was performed on average within 11.7 days of injury, and the average hospital stay was 18.2 days (range, 6 to 18 days). Early post-operative complications were recorded in six patients (20.7 %). Wound dehiscence was found in two (6.9 %), necrosis of wound edges in two (6.9 %), and early superficial infection responding to antibiotic therapy also in two patients (6.9 %). Deep infection, non-union or post-operative compartment syndrome were not recorded. Excellent Rowe scores were achieved in 10 patients (34.5 %), good in 15 (51.7 %) and satisfactory in two (6.9 %). Only two patients (6.9 %) reported poor outcome. The methods of classification and treatment of calcaneal fractures continue to be a frequently discussed topic. The technique of ORIF-calcaneal LCP from an extended lateral approach has recently been preferred for patients with displaced Sanders type II or III calcaneal fractures. In agreement with other literature references, this approach allowed us to observe the fracture, to reduce both the subtalar and calcaneocuboid articulations, to stabilize the fracture by internal fixation and to begin early rehabilitation. Because of the risk of early complications, the timing of surgery and a thorough consideration of indications and contraindications are of principal importance.We agree with other authors that filling calcaneal bone defects is not necessary. Pre- and post-operative CT scans are necessary. In accordance with literature data, fractures developing compartment syndrome are indicated for urgent fasciotomy and ORIF-calcaneal LCP should be postponed. In patients with multiple trauma and also in those with open calcaneal fractures, a temporary stabilization with an external fixator medially is performed first, and then converted to a second-stage, ORIF-LCP procedure. The surgical treatment of displaced intra-articular fractures that involves open reduction from an extended lateral approach and internal fixation with a calcaneal LCP shows very good preliminary results. A CT examination is required for the diagnosis and classification of fractures and a correct indication for surgery. Good timing is of principal importance. An urgent surgical intervention is necessary in open fractures or in those in which soft tissues are squashed by bone fragments. In the other fractures, surgery is carried out after oedema subsidence. Foot compartment syndrome is a serious complication of calcaneal fractures and urgent fasciotomy is the only adequate therapy. Full weight-bearing of the operated extremity depends on the rate of bone healing; it is usually allowed at 3 months after surgery.

  19. [Treatment of calcaneal fractures using the medial approach for open reduction].

    PubMed

    Vanĕcek, L; Malkus, T; Dungl, P

    2003-01-01

    A comprehensive evaluation of the treatment of calcaneal fractures by open reduction is presented. The long-term results are compared with the relevant literature data. In the period from 1987 to 2000, 60 displaced fractures of the calcaneus were treated in 51 patients. Of these, 49 patients suffered the fracture by falling from a height, which is generally the most common cause. Only two patients were injured during sports activities. Thirty eight injuries were classified as fractures of the joint depression type and 22 as fractures of the tongue type. The patients had surgery on the day they sustained the injury or after edema had subsided, if this was present on admission. The interval between injury and surgery was 4.6 days on the average. The fracture was fixed with Kirschner's wires (Kw) in 53 cases, a Kirshcner's wire and a hook-nail in five cases and a Kirchner's wire and a spongious screw in two patients. In May 2001, 23 patients were available for evaluation after a follow-up period of 6 to 120 months. The patients underwent clinical and radiographic examination and filled a questionnaire. The fracture type was defined on the basis of the Essex-Lopresti classification system. Outcomes were scored according to the Creighton-Nebraska Health Foundation rating system that assessed pain, range of motion, edema, a change in shoe size, patient's activity after therapy termination and return to a job. In May 2001, 23 patients, with a follow-up ranging from 6 to 120 months were checked up. Of them, 20 (86.9%) had neither clinical manifestations nor subjective complaints. Three patients retired because of persisting complaints, two with disability pensions and one with an old-age pension. A total of 19 patients were evaluated by the Creighton-Nebraska Health Foundation rating system. The average score was 90.8 points. The results were excellent in 15 patients, good in three and poor in one patient. The complications reported by the patients included superficial infection in two, thromboembolic disease in one, and hypesthesia on the medial side of the leg in two patients. The optimal mode of treatment in dislocated intra-articular fractures of the calcaneus still remains open to discussion. Should conservative or surgical therapy be used? In agreement with others, the authors preferred early surgical intervention. This facilitated a better congruence of the dorsal articular surface. The average remaining dislocation of the articular surface was 1.1 mm in surgically treated as against the average of 4.7 mm in conservatively treated patients. It was possible to restore the length, height and width, and the correct axial position of the calcaneus by this surgery from the medial approach. However, in indicated cases, the procedure required an additional intervention from the lateral approach through a mini-incision. As reported in the literature, other authors have achieved comparable, or even better results but on the basis of either the lateral or the plantar approach. The application of primary spongioplasty or primary arthrodesis of the subtalar joint is discussed. The advantages of preoperative examination by computer-assisted tomography are emphasized. Good outcomes of the treatment of intra-articular, dislocated calcaneal fractures depend on a correct shape and position of the dorsal articular surface of the calcaneus. The open reduction procedure from the medial approach based on the principles of McReynold's technique allowed us to accomplish both these criteria.

  20. Evaluation of an improved prototype mini-baghouse to control the release of respirable crystalline silica from sand movers.

    PubMed

    Alexander, Barbara M; Esswein, Eric J; Gressel, Michael G; Kratzer, Jerry L; Feng, H Amy; Miller, Arthur L; Cauda, Emanuele; Heil, Graeham

    2018-01-01

    The OSHA final rule on respirable crystalline silica (RCS) will require hydraulic fracturing companies to implement engineering controls to limit workers' exposure to RCS. RCS is generated by pneumatic transfer of quartz-containing sand during hydraulic fracturing operations. Chronic inhalation of RCS can lead to serious disease, including silicosis and lung cancer. NIOSH research identified at least seven sources where RCS aerosols were generated at hydraulic fracturing sites. NIOSH researchers developed an engineering control to address one of the largest sources of RCS aerosol generation, RCS escaping from thief hatches on the top of sand movers. The control, the NIOSH Mini-Baghouse Retrofit Assembly (NMBRA), mounts on the thief hatches. Unlike most commercially available engineering controls, the NMBRA has no moving parts and requires no power source. This article details the results of an evaluation of generation 3 of the NMBRA at a sand mine in Arkansas from May 19-21, 2015. During the evaluation, 168 area air samples were collected at 12 locations on and around a sand mover with and without the NMBRA installed. Analytical results for respirable dust and RCS indicated the use of the NMBRA effectively reduced concentrations of both respirable dust and RCS downwind of the thief hatches. Reductions of airborne respirable dust were estimated at 99+%; reductions in airborne RCS ranged from 98-99%. Analysis of bulk samples of the dust showed the likely presence of freshly fractured quartz, a particularly hazardous form of RCS. Use of an improved filter fabric and a larger area of filter cloth led to substantial improvements in filtration and pressures during these trials, as compared to the generation 2 NMBRA. Planned future design enhancements, including a weather cover, will increase the performance and durability of the NMBRA. Future trials are planned to evaluate the long-term operability of the technology.

  1. Maxillofacial fracture epidemiology and treatment plans in the Northeast of Iran: A retrospective study

    PubMed Central

    Samieirad, Sahand; Aboutorabzade, Mohammad-Reza; Tohidi, Elahe; Shaban, Baratollah; Khalife, Hussein; Salami, Hamid-Reza

    2017-01-01

    Background The epidemiology of facial injuries varies based on lifestyle, cultural background and socioeconomic status in different countries and geographic zones. This study evaluated the epidemiology of maxillofacial fractures and treatment plans in hospitalized patients in Northeast of Iran (2015-2016). Material and Methods In this retrospective study, the medical records of 502 hospitalized patients were evaluated in the Department of Maxillofacial Surgery in Kamyab Hospital in Mashhad, Iran. The type and cause of fractures and treatment plans were recorded in a checklist. Data were analyzed with Mann–Whitney test, chi-squared test and Fisher’s exact test, using SPSS 21. Results The majority of patients were male (80.3%). Most subjects were in 20-30-year age range (43.2%). The fractures were mostly caused by accidents, particularly motorcycle accidents (MCAs), and the most common site of involvement was the body of the mandible. There was a significant association between the type of treatment and age. In fact, the age range of 16-59 years underwent open reduction internal fixation (ORIF) more than other age ranges (P=0.001). Also, there was a significant association between gender and fractures (P=0.002). Conclusions It was concluded that patient age and gender and trauma significantly affected the prevalence of maxillofacial traumas, fracture types and treatment plans. This information would be useful for making better health policy strategies. Key words:Epidemiology, treatment, facial injuries, maxillofacial fractures, trauma. PMID:28809369

  2. Surgical management of coracoid fractures: technical tricks and clinical experience.

    PubMed

    Hill, Brian W; Jacobson, Aaron R; Anavian, Jack; Cole, Peter A

    2014-05-01

    The coracoid process plays a pivotal role in the foundation of the coracoacromial arch and in cases of displaced fractures; surgical management may be warranted to avoid functional compromise or impingement. A direct approach through Langer's lines allows for easy exposure and direct visualization for an anatomic reduction of simple fractures through the shaft or base of the coracoid. An anterior approach for fractures that extend into the superior glenoid fossa allows for direct exposure to obtain an anatomic articular reduction and indirect reduction of the coracoid fracture. In cases where a complex glenoid or scapula neck/body fracture is being addressed simultaneously either a posterior Judet approach can be used with an indirect reduction method or a separate anterior approach must be combined to address it if not in continuity with the superior scapular segment. Implant selection, primarily interfragmentary screws or a buttress plate, should be based on the size of the fragment, the degree of comminution, and the degree of articular involvement to ensure adequate stabilization. The purpose of this manuscript was to describe a stepwise approach to the surgical management of displaced coracoid fractures, describe surgical tips and techniques, and to present the clinical outcomes in 22 patients after surgical treatment with this approach.

  3. Extraoral approach to mandibular condylar fractures: our experience with 100 cases.

    PubMed

    Colletti, Giacomo; Battista, Valeria Marinella Augusta; Allevi, Fabiana; Giovanditto, Federica; Rabbiosi, Dimitri; Biglioli, Federico

    2014-07-01

    Mandibular condylar fractures are very common. The current literature contains many indications and methods of treatment. Extraoral approaches are complicated by the need to avoid injury to the facial nerve. On the other hand intraoral approaches can make fracture reduction and/or fixation difficult. The mini-retromandibular approach provides an excellent view of the surgical field, minimises the risk of injury to the facial nerve, and allows rapid and easy management of condylar fractures. We have collected and reviewed our first 100 condylar fractures treated by means of a mini-retromandibular approach. Between June 2006 and June 2012, Eighty-seven patients with extracapsular condylar fractures underwent open reduction and rigid fixation for 100 extracapsular condylar fractures via a mini-retromandibular approach. Dental occlusion and anatomic reduction were restored in all 100 condylar fractures. Postoperative infection developed in three patients. There was one sialocele and one case of plate fracture. Four patients experienced transient palsy of the buccal branch of the facial nerve. No permanent deficit of any facial nerve branch was observed. No patient showed condylar head resorption. Our experience with the treatment of the first 100 condylar fractures using the mini-retromandibular approach has demonstrated that this technique has allowed the Authors to safely manage extracapsular condylar fractures at all levels. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Pediatric facial fractures: evolving patterns of treatment.

    PubMed

    Posnick, J C; Wells, M; Pron, G E

    1993-08-01

    This study reviews the treatment of facial trauma between October 1986 and December 1990 at a major pediatric referral center. The mechanism of injury, location and pattern of facial fractures, pattern of facial injury, soft tissue injuries, and any associated injuries to other organ systems were recorded, and fracture management and perioperative complications reviewed. The study population consisted of 137 patients who sustained 318 facial fractures. Eighty-one patients (171 fractures) were seen in the acute stage, and 56 patients (147 fractures) were seen for reconstruction of a secondary deformity. Injuries in boys were more prevalent than in girls (63% versus 37%), and the 6- to 12-year cohort made up the largest group (42%). Most fractures resulted from traffic-related accidents (50%), falls (23%), or sports-related injuries (15%). Mandibular (34%) and orbital fractures (23%) predominated; fewer midfacial fractures (7%) were sustained than would be expected in a similar adult population. Three quarters of the patients with acute fractures required operative intervention. Closed reduction techniques with maxillomandibular fixation were frequently chosen for mandibular condyle fractures and open reduction techniques (35%) for other regions of the facial skeleton. When open reduction was indicated, plate-and-screw fixation was the preferred method of stabilization (65%). The long-term effects of the injuries and the treatment given on facial growth remain undetermined. Perioperative complication rates directly related to the surgery were low.

  5. [Influence of spinal orthosis on gait and physical functioning in women with postmenopausal osteoporosis].

    PubMed

    Schmidt, K; Hübscher, M; Vogt, L; Klinkmüller, U; Hildebrandt, H D; Fink, M; Banzer, W

    2012-03-01

    Osteoporosis is a widespread chronic bone disease leading to an increased risk of bone fractures. The most common clinical consequences are back pain, hyperkyphosis, limitations of physical functioning and activities of daily living as well as reduced quality of life. Furthermore, osteoporosis is associated with decreased strength and deficits of gait and balance, all together resulting in an increased risk of falls and a subsequent aggravation of fracture risk. Besides pharmaceutical and exercise therapy, back orthoses are increasingly being used in the therapy of osteoporosis and rehabilitation after vertebral fractures. Previous studies have shown that wearing a spinal orthosis results in a reduction of pain as well as improvements of posture and back extensor strength. To date there is no study that has evaluated the effects of a spinal orthosis on gait stability and physical functioning in patients with osteoporosis. Therefore the purpose of the present study was to assess the effects of a spinal orthosis on gait and pain-induced limitations of activities of daily living (ADL) in women with osteoporosis. A total of 69 postmenopausal osteoporotic women with and without vertebral fractures were randomly assigned to receive either a spinal orthosis (Thämert Osteo-med intervention group n=35; average age 74 ± 8.3 years, height 158.3 ± 6.3 cm, weight 62.8 ± 9.6 kg, t-score -2.6  ± 1.0, number of vertebral fractures 1.4 ± 2.0) or to a waiting list control group (n= 34, age 74.1 ± 7.7 years, height 159.6 ± 5.9 cm, weight 65.4 ± 11.3 kg, t-score -2.9± 0.8, number of vertebral fractures: 0.9 ± 1.2). The following outcome measures were collected at baseline and at 3 and 6 months follow-up: gait parameters including gait analysis: velocity, stride length and width, double support time (% of gait cycle) and perceived limitations in activities of daily living (numeric rating scale 1-10; 1=best, 10= worst situation). The ANCOVA indicated a significant reduction of the double support time at 6 months in the intervention group (p < 0.05) without a significant influence of the covariate vertebral fractures status. The other parameters remained unchanged (p > 0 .05). Regarding the pain-related ADL limitations there were significant differences in the amount of change over the study period depending on the baseline value. Stratified into terciles (≤ 2.5; 2.6-5.0; >5) patients with initially high values showed a significantly greater reduction in perceived ADL restrictions compared to patients in the lowest tercile (-2.7 ± 2.7 versus 1.5 ± 2.1). The study demonstrated that wearing a spinal orthosis introduced a reduction in double support time associated with a beneficial impact on gait stability. Furthermore, there was a positive effect on pain-related restrictions of ADL evident in women with a high level of limitations at baseline. Besides previously shown reductions in pain, improvements in back extensor strength and correction of posture, the application of a spinal orthosis may induce advantages for gait stability and physical functioning in women with postmenopausal osteoporosis. Future studies should consider a longer follow-up to evaluate possible effects on the risk of falling and fractures.

  6. Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring.

    PubMed

    Khan, I; Dar, M Y; Rashid, S; Butt, M F

    2016-07-01

    Aims : To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1) or transverse with mildly comminuted (AO34-C2) patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the patients were treated with open reduction and internal fixation using two parallel cannulated screws and 18G stainless steel wire as per the tension band principle. Results : There were eighteen males (72%) and seven females (28%). The age group ranged from 24 to 58 years, with mean age of 38 years. The most common mode of injury was fall (72%) followed by road traffic accident (20%) and violent quadriceps contraction (8%). Transverse fracture was present in 60% and transverse fracture with mild comminution in 40% of patients. Mean time to achieve union was 10.7 weeks (range 8-12 weeks). Mean ROM at three months was 113.8 degree (90-130) and at final follow up this improved to 125.4 degrees (range 100-140). There was one case of knee stiffness and no case of implant failure was observed. Patients were evaluated using Bostman scoring, the mean score at three months being 26.04 which improved to 27.36 at the end of final follow up at one year. Conclusion : Cannulated cancellous screws with anterior tension band wiring is a safe, reliable and reproducible method in management of transverse patellar fractures, with less chances of implant failure and soft tissue irritation.

  7. Surgical treatment of displaced intra-articular calcaneal fracture using a single small lateral approach

    PubMed Central

    El-Adl, Gamal; Hassanin, Ehab Y.; Abdellatif, M-Serry

    2010-01-01

    The objective of this study was to evaluate the outcome of semi-open reduction and minimal internal fixation through a single small lateral approach as a minimally invasive technique for treatment of displaced intra-articular calcaneal fractures. This prospective study was conducted on eighteen patients (16 men and 2 women). The average age was 37.7 (22–55). The most common cause of injury was a fall from height in fourteen patients. Patients were operated on within a mean time of 4.8 days of admission (1–11 days) and were followed up for an average period of 24.1 months (6–39 months). Patients were evaluated clinically using the Creighton-Nebraska Heath Foundation Assessment score of Crosby and Fitzgibbons (J Bone Joint Surg (Am) 72-A:852–859, 1990). The scoring system proposed by Knirk and Jupiter was used for radiological assessment of the posterior subtalar joint (Knirk and Jupiter in J Bone Joint Surg (Am) 68-A: 647–659, 1986). The skin incision healed in all cases without necrosis, infection, or sural nerve injury. All fractures healed after an average of 8 weeks (7–10 weeks), and patients returned to the routine daily activities after an average time of 4.3 months (3–7 months). In conclusion, semi-open reduction and minimal internal fixation through a small lateral approach is an effective treatment for carefully selected cases of displaced intra-articular calcaneal fractures. PMID:21811904

  8. [Pharmacogenic osteoporosis beyond cortisone. Proton pump inhibitors, glitazones and diuretics].

    PubMed

    Kann, P H; Hadji, P; Bergmann, R S

    2014-05-01

    [corrected] There are many drugs which can cause osteoporosis or at least favor its initiation. The effect of hormones and drugs with antihormonal activity, such as glucocorticoids and aromatase inhibitors, on initiation of osteoporosis is well known. In addition, proton pump inhibitors, glitazones and diuretics also influence the formation of osteoporosis. The results of currently available studies on the correlation between proton pump inhibitors, glitazones and diuretics on formation of osteoporosis were evaluated and summarized. Proton pump inhibitors and glitazones increase the risk for osteoporotic fractures. Loop diuretics may slightly increase fracture risk, whereas thiazides were shown to be osteoprotective by reducing fracture probability on a relevant scale. Proton pump inhibitors should not be prescribed without serious consideration and then only as long as necessary. Alternatively, the administration of the less effective H2 antagonists should be considered when possible due to the reduction of acid secretion. Because the long-term intake of thiazides is associated with a clinically relevant reduction in the risk of fractures and they are economic and well-tolerated, prescription can be thoroughly recommended within the framework of differential diagnostic considerations in an appropriate clinical context. The briefly increased risk of falling immediately after starting diuretic therapy is the only point which needs to be considered.

  9. Haptic feedback improves surgeons' user experience and fracture reduction in facial trauma simulation.

    PubMed

    Girod, Sabine; Schvartzman, Sara C; Gaudilliere, Dyani; Salisbury, Kenneth; Silva, Rebeka

    2016-01-01

    Computer-assisted surgical (CAS) planning tools are available for craniofacial surgery, but are usually based on computer-aided design (CAD) tools that lack the ability to detect the collision of virtual objects (i.e., fractured bone segments). We developed a CAS system featuring a sense of touch (haptic) that enables surgeons to physically interact with individual, patient-specific anatomy and immerse in a three-dimensional virtual environment. In this study, we evaluated initial user experience with our novel system compared to an existing CAD system. Ten surgery resident trainees received a brief verbal introduction to both the haptic and CAD systems. Users simulated mandibular fracture reduction in three clinical cases within a 15 min time limit for each system and completed a questionnaire to assess their subjective experience. We compared standard landmarks and linear and angular measurements between the simulated results and the actual surgical outcome and found that haptic simulation results were not significantly different from actual postoperative outcomes. In contrast, CAD results significantly differed from both the haptic simulation and actual postoperative results. In addition to enabling a more accurate fracture repair, the haptic system provided a better user experience than the CAD system in terms of intuitiveness and self-reported quality of repair.

  10. Causes and treatment of mandibular and condylar fractures in children and adolescents: a review of 104 cases.

    PubMed

    Shi, Jun; Chen, Zhibiao; Xu, Bing

    2014-03-01

    There are no uniform treatments, standards, and specifications for conservative and surgical management of mandibular fractures in children and adolescents. To review the management of mandibular fractures in children and adolescents at our institution. The medical records of 104 children and adolescents (60 male and 44 female) treated for mandibular fractures from 2005 to 2012 at the Ninth People's Hospital, Shanghai, China, were retrospectively reviewed. The participants were classified as having deciduous dentition (age ≤6 years), mixed dentition (age >6 but <12 years), and permanent dentition (age ≥12 but ≤16 years). Conservative treatment and surgical management. Helkimo clinical dysfunction and anamnestic indices. Condylar process fractures accounted for 55.7% of the fractures (112 fractures of 201 total fracture sites), and symphysis fractures, parasymphysis fractures, fractures of the body, and fractures of the angle accounted for 20.9%, 11.9%, 7.0%, and 3.5% of the fractures, respectively. A total of 83 cases with 159 fracture sites with complete follow-up data were included in the treatment analysis. In these 83 patients, 77 fractures were dentigerous bone fractures, 46 were intracapsular fractures, and 36 were extracapsular fractures. Dentigerous bone fractures of the mandible were managed by closed or open reduction in children younger than 12 years and were managed more often by open reduction and fixation in those between ages 12 and 16 years. Closed treatment was performed for 22 condylar process fractures (28.6%), and open reduction was carried out for 55 condylar process fractures (71.4%). In patients with intracapsular fractures, there was no significant relationship between dentation age and treatment method (P = .06). Most patients with extracapsular fractures with permanent dentition underwent surgical fixation (73.3%), whereas most with deciduous dentition received conservative treatment (87.5%). In patients with condylar process fractures, there was no significant difference in Ai and Di based on treatment method (P = .49 and P = .76, respectively). The treatment of mandibular fractures in children and adolescents should be determined by clinical factors including age, location, and type of fracture.

  11. Biodegradable fixation of mandibular fractures in children: stability and early results.

    PubMed

    Yerit, Kaan C; Hainich, Sibylle; Enislidis, Georg; Turhani, Dritan; Klug, Clemens; Wittwer, Gert; Ockher, Michael; Undt, Gerhard; Kermer, Christian; Watzinger, Franz; Ewers, Rolf

    2005-07-01

    The aim of this study was to assess the safety and efficiency of biodegradable self-reinforced (SR-PLDLA) bone plates and screws in open reduction and internal fixation of mandible fractures in children. Thirteen patients (5 female, 8 male; mean age 12 years, range 5-16 years) were operated on various fractures of the mandible (2 symphyseal, 6 parasymphyseal, 4 body, 3 angle, 1 ramus, 2 condylar fractures). The mean follow-up time was 26.4 months (range 10.9-43.4 months). Intermaxillary fixation was applied in cases with concomitant condylar fractures up to 3 weeks. Primary healing of the fractured mandible was observed in all patients. Postoperative complications were minor and transient. The outcome of the operations was not endangered. Adverse tissue reactions to the implants, malocclusion, and growth restrictions did not occur during the observation period. Pediatric patients benefit from the advantages of resorbable materials, especially from faster mobilization and the avoidance of secondary removal operations. Based on these preliminary results, self-reinforced fixation devices are safe and efficient in the treatment of pediatric mandible fractures. However, further clinical investigations are necessary to evaluate the long-term reliability.

  12. Lateral compression open cap splint with circummandibular wiring for management of pediatric mandibular fractures: a retrospective audit of 10 cases.

    PubMed

    Bhola, Nitin; Jadhav, Anendd; Borle, Rajiv; Khemka, Gaurav; Adwani, Nitin; Bhattad, Mayur

    2014-03-01

    Mandibular fractures are relatively less frequent in children when compared to adults. Pediatric patients present a unique challenge to maxillofacial surgeons in terms of their treatment planning and in their functional needs. We currently describe our experience with lateral compression open cap splint with circummandibular wiring as a treatment modality which involves fewer risks in treating pediatric symphysis/parasymphysis/body mandibular fractures. A retrospective analysis of pediatric patients with mandibular symphysis/parasymphysis/body fractures operated from January 2007 to January 2012 was performed. Clinical photographs and orthopantomogram assessment at the time of presentation, after treatment, and at 6 months postoperatively were evaluated. All the 10 patients were followed up until the period of 6 months, and none of them had any major complications. Postoperatively, there was satisfactory healing and union of fracture fragments in all the patients. Only one patient developed infection at submental region. The 6-month follow-up showed good occlusion, without interference in teeth eruption and no signs of temporomandibular joint problems. Lateral compression open cap splints for treatment of pediatric mandibular symphysis/parasymphysis/body fractures are reliable treatment modalities with regard to occlusion-guided fracture reduction.

  13. [Clinical practice guideline on closed tibial plateau fractures in adulthood].

    PubMed

    Ocegueda-Sosa, Miguel Ángel; Valenzuela-Flores, Adriana Abigail; Aldaco-García, Víctor Daniel; Flores-Aguilar, Sergio; Manilla-Lezama, Nicolás; Pérez-Hernández, Jorge

    2013-01-01

    Closed tibiae plateau fractures are common injuries in the emergency room. The optimal treatment is not well defined or established. For this reason, there are several surgical management options: open reduction and internal fixation, closed reduction and percutaneous synthesis, external fixation, and even conservative treatment for this kind of fracture. The mechanism of production of this fracture is through large varus or valgus deformation to which is added a factor of axial load. The trauma may be direct or indirect. The degree of displacement, fragmentation and involvement of soft tissues like ligaments, menisci, vascular and nerve structures are determined by the magnitude of the force exerted. Any intra-articular fracture treatment can lead to an erroneous instability, deformity and limitation of motion with subsequent arthritic changes, leading to joint incongruity, limiting activity and significantly altering the quality of life. Open reduction and internal fixation with anatomic restitution is the method used in this type of fracture. However, the results of numerous publications can be questioned due to the inclusion in the same study of fractures treated with very different methods.

  14. Analysis of foot structure in athletes sustaining proximal fifth metatarsal stress fracture.

    PubMed

    Hetsroni, Iftach; Nyska, Meir; Ben-Sira, David; Mann, Gideon; Segal, Ofer; Maoz, Guy; Ayalon, Moshe

    2010-03-01

    In the past, several studies provided anecdotal descriptions of high-arched feet in individuals sustaining proximal fifth metatarsal stress fractures. This relationship has never been supported by scientific evidence. Our objective was to examine whether athletes who sustained this injury had an exceptional static foot structure or dynamic loading pattern. Ten injured professional soccer players who regained full professional activity following a unilateral proximal fifth metatarsal stress fracture and ten control soccer players were examined. Independent variables included static evaluation of foot and arch structure, followed by dynamic plantar foot pressure evaluation. Each variable was compared between injured, contra-lateral uninjured, and control feet. Static measurements of foot and arch structure did not reveal differences among the groups. However, plantar pressure evaluation revealed relative unloading of the fourth metatarsal in injured and uninjured limbs of injured athletes compared with control, while the fifth metatarsal revealed pressure reduction only in the injured limbs of injured athletes. Athletes who sustained proximal fifth metatarsal stress fracture were not characterized by an exceptional static foot structure. Dynamically, lateral metatarsal unloading during stance may either play a role in the pathogenesis of the injury, or alternately represent an adaptive process. Footwear fabrication for previously injured athletes should not categorically address cushioning properties designed for high-arch feet, but rather focus on individual dynamic evaluation of forefoot loading, with less attention applied to static foot and arch characteristics.

  15. Management of Hip Fractures in Lateral Position without a Fracture Table.

    PubMed

    Pahlavanhosseini, Hamid; Valizadeh, Sima; Banadaky, Seyyed Hossein Saeed; Karbasi, Mohammad H Akhavan; Abrisham, Seyed Mohammad J; Fallahzadeh, Hossein

    2014-09-01

    Hip fracture Management in supine position on a fracture table with biplane fluoroscopic views has some difficulties which leads to prolongation of surgery and increasing x- rays' dosage. The purpose of this study was to report the results and complications of hip fracture management in lateral position on a conventional operating table with just anteroposterior fluoroscopic view. 40 hip fractures (31 trochanteric and 9 femoral neck fractures) were operated in lateral position between Feb 2006 and Oct 2012. Age, gender, fracture classification, operation time, intra-operation blood loss, reduction quality, and complications were extracted from patients' medical records. The mean follow-up time was 30.78±22.73 months (range 4-83). The mean operation time was 76.50 ± 16.88 min (range 50 - 120 min).The mean intra-operative blood loss was 628.75 ± 275.00 ml (range 250-1300ml). Anatomic and acceptable reduction was observed in 95%of cases. The most important complications were malunion (one case in trochanteric group), avascular necrosis of femoral head and nonunion (each one case in femoral neck group). It sounds that reduction and fixation of hip fractures in lateral position with fluoroscopy in just anteroposterior view for small rural hospitals may be executable and probably safe.

  16. Management of Hip Fractures in Lateral Position without a Fracture Table

    PubMed Central

    Pahlavanhosseini, Hamid; Valizadeh, Sima; Banadaky, Seyyed Hossein Saeed; Karbasi, Mohammad H Akhavan; Abrisham, Seyed Mohammad J; Fallahzadeh, Hossein

    2014-01-01

    Background: Hip fracture Management in supine position on a fracture table with biplane fluoroscopic views has some difficulties which leads to prolongation of surgery and increasing x- rays' dosage. The purpose of this study was to report the results and complications of hip fracture management in lateral position on a conventional operating table with just anteroposterior fluoroscopic view. Methods: 40 hip fractures (31 trochanteric and 9 femoral neck fractures) were operated in lateral position between Feb 2006 and Oct 2012. Age, gender, fracture classification, operation time, intra-operation blood loss, reduction quality, and complications were extracted from patients' medical records. The mean follow-up time was 30.78±22.73 months (range 4-83). Results: The mean operation time was 76.50 ± 16.88 min (range 50 - 120 min).The mean intra-operative blood loss was 628.75 ± 275.00 ml (range 250-1300ml). Anatomic and acceptable reduction was observed in 95%of cases. The most important complications were malunion (one case in trochanteric group), avascular necrosis of femoral head and nonunion (each one case in femoral neck group). Conclusions: It sounds that reduction and fixation of hip fractures in lateral position with fluoroscopy in just anteroposterior view for small rural hospitals may be executable and probably safe. PMID:25386577

  17. Complications of Nasal Bone Fractures.

    PubMed

    Hwang, Kun; Yeom, Seung Han; Hwang, Suk Hyun

    2017-05-01

    The aim of this study was to perform a systematic review of the treatment of nasal bone fractures. The search terms ("nasal bone fracture" AND complication) and ("nasal bone fracture" AND [anosmia OR olfaction OR olfactory nerve OR smell]) and (anosmia AND ["nasal preparation" OR "nasal antiseptics"]) were used to search PubMed and SCOPUS. Of the 500 titles, 40 full papers were reviewed. One paper was excluded, and 3 mined papers were added. Ultimately, 12 papers were analyzed. The overall deformity rate was 10.4% ± 4.8%. No significant differences were found between patients who underwent closed reduction (14.7% ± 7.3%) and those who underwent open reduction (9.4% ± 4.4%), between those who underwent local anesthesia (5.8% ± 4.5%), and those who underwent general anesthesia (8.8% ± 3.8%), or between those who received timely treatment (5.7%) and those whose treatment was delayed (9.0%). Septal deviation occurred in 10.0% of patients as a sequela of nasal bone fracture. The nasal obstruction rate was 10.5% ± 5.3%. Fewer patients of nasal obstruction occurred in the open reduction patients (6.9% ± 4.4%) than in the closed reduction patients (15.2%). One patient of epiphora and 1 patient of diplopia were reportedAmong the 77 patients with nasal bone fractures, 29 (37.7% ± 11.3%) complained of olfactory disturbances. No significant associations were found between the type of fracture and the presence of olfactory disturbances. It is recommended for providers to explain to patients that approximately one-tenth of nasal bone fractures exhibit deformity, septal deviation, or nasal obstruction after surgery. Surgeons should take considerable care to avoid the olfactory mucosa during reduction surgery.

  18. [New techniques in the operative treatment of calcaneal fractures].

    PubMed

    Rammelt, S; Amlang, M; Sands, A K; Swords, M

    2016-03-01

    The ideal treatment of displaced intra-articular calcaneal fractures is still controversially discussed. Because of the variable fracture patterns and the vulnerable soft tissue coverage an individual treatment concept is advisable. In order to minimize wound edge necrosis associated with extended lateral approaches, selected fractures may be treated percutaneously or in a less invasive manner while controlling joint reduction via a sinus tarsi approach. Fixation in these cases is achieved with screws, intramedullary locking nails or modified plates that are slid in subcutaneously. A thorough knowledge of the three dimensional calcaneal anatomy and open reduction maneuvers is a prerequisite for good results with less invasive techniques. Early functional follow-up treatment aims at early rehabilitation independent of the kind of fixation. Peripheral fractures of the talus and calcaneus frequently result from subluxation and dislocation at the subtalar and Chopart joints. They are still regularly overlooked and result in painful arthritis if left untreated. If an exact anatomical reduction of these intra-articular fractures is impossible, resection of small fragments is indicated.

  19. Factors Associated With Narcotic Use After Clavicle Fractures.

    PubMed

    Weinberg, Douglas S; Napora, Joshua K; West, William H; Grimberg, Dominic C; Vallier, Heather A

    2016-09-01

    Clavicle fractures are common in adults. Recent studies have shown that operative treatment of clavicle fractures has benefits in many situations. However, there is controversy about the indications. Data on social outcomes are limited. A total of 434 patients with 436 clavicle fractures treated both operatively and nonoperatively at a level 1 trauma center were identified. Narcotic use was recorded 2, 4, 6, 8, 10, 12, 14, and 16 weeks after injury for both treatment groups. Other descriptive data included age, sex, laterality, hand dominance, rib fractures, smoking, alcohol use, employment, long bone or spine fracture, open clavicle fracture, and mechanism of injury. Logistic regression analysis was performed to determine the independent predictors of narcotic use after clavicle fracture. Open reduction and internal fixation was performed in 105 fractures (24%), and 329 fractures were managed nonoperatively. A total of 154 patients (35%) reported some narcotic use 2 weeks after injury, and 15% were still using narcotics 16 weeks after injury. Narcotic use decreased over time in patients treated with open reduction and internal fixation (10% vs 15% after nonoperative management). Patients treated with open reduction and internal fixation reported reduced narcotic use at 16 weeks (odds ratio [OR], 0.454; P=.070). Concurrent rib fracture (OR, 5.668; P<.001), smoking (OR, 3.095; P=.013), unemployment (OR, 5.429; P<.0005), and long bone or spine fracture (OR, 6.761; P<.001) were predictors of narcotic use. Further studies of the social, economic, and financial outcomes of clavicle fracture and osteosynthesis are warranted. [Orthopedics. 2016; 39(5):e917-e923.]. Copyright 2016, SLACK Incorporated.

  20. Complications after pinning of supracondylar distal humerus fractures.

    PubMed

    Bashyal, Ravi K; Chu, Jennifer Y; Schoenecker, Perry L; Dobbs, Matthew B; Luhmann, Scott J; Gordon, J Eric

    2009-01-01

    Supracondylar distal humerus fractures are one of the most common skeletal injuries in children. The current treatment of choice in North America is closed reduction and percutaneous pin fixation. Often surgeons leave the pins exposed beneath a cast but outside the skin. Great variation exists with respect to preoperative skin preparation, and perioperative antibiotic administration. Few data exist regarding the rate of infection and other complications. The purpose of this study is to review a large series of children to evaluate the rate of infection and other complications. A retrospective review was carried out of all patients treated at our institution over an 11-year period. A total of 622 patients were identified that were followed for a minimum of 2 weeks after pin removal. Seventeen patients had flexion-type fractures, 294 had type II fractures, and 311 had type III fractures. Seventy-four fractures (11.9%) had preoperative nerve deficits with anterior interosseous palsies being the most common (33 fractures, 5.3%). Preoperative antibiotics were given to 163 patients (26.2%). Spray and towel draping were used in 362 patients, paint and towel draping were used in 65 patients, alcohol paint and towel draping were used in 146 patients, and a full preparation and draping were used in 13 patients. The pins were left exposed under the cast in 591 fractures (95%), and buried beneath the skin in 31 fractures (5.0%). A medial pin was placed in 311 fractures with a small incision made to aid placement in 18 of these cases. The most common complication was pin migration necessitating unexpected return to the operating room for pin removal in 11 patients (1.8%). One patient developed a deep infection with septic arthritis and osteomyelitis (0.2%). Five additional patients had superficial skin infections and were treated with oral antibiotics for a total infection rate of 6 of 622 patients (1.0%). One patient ultimately had a malunion and 4 others returned to the operating room for repeat reduction and pinning. Three patients developed compartment syndromes. Ulnar nerve injury was rare with only 1 postoperative ulnar nerve injury occurring in 311 patients treated with a medial pin (0.3%). Closed reduction with percutaneous pinning is effective and has a low complication rate with a very low rate of infection even when simple betadine preparation and towel draping are used. Preoperative antibiotics seem to have little effect on infection rate. Level III retrospective comparative study.

  1. Evaluation of the Mechanical Properties of Electroslag Refined Fe-12Ni Alloys

    NASA Technical Reports Server (NTRS)

    Bhat, G. K.

    1978-01-01

    Three Fe-12Ni alloys, individually alloyed with small amounts of V, Ti, and Al, were manufactured through different melting techniques, with special emphasis on electroslag remelting, in order to achieve different levels of metal purity and associated costs. The relative effectiveness of these melting techniques was evaluated from tensile and slow bend fracture toughness behavior at 25 C and -196 C after tempering the test specimens at various temperatures. The best melting procedure was vacuum induction melting (VIM) with or without electroslag remelting (ESR). VIM+ESR is the recommended procedure since ESR provides increased yield of plate product, a reduction of overall manufacturing costs and, depending on the alloy composition, improved tensile and fracture toughness properties.

  2. A Comparison of Three Different Methods of Fixation in the Management of Thoracolumbar Fractures.

    PubMed

    Panteliadis, Pavlos; Musbahi, Omar; Muthian, Senthil; Goyal, Shivam; Montgomery, Alexander Sheriff; Ranganathan, Arun

    2017-01-01

    Management of thoracolumbar fractures remains controversial in the literature. The primary aims of this study were to assess different levels of fixation with respect to radiological outcomes in terms of fracture reduction and future loss of correction. This is a single center, retrospective study. Fifty-five patients presenting with thoracolumbar fractures between January 2012 and December 2015 were analyzed in the study. The levels of fixation were divided in 3 groups, 1 vertebra above and 1 below the fracture (1/1), 2 above and 2 below (2/2), and 2 above and 1 below (2/1). The most common mechanism was high fall injury and the most common vertebra L1. Burst fractures were the ones with the highest incidence. The 2/2 fixation achieved the best reduction of the fracture but with no statistical significance. The correction is maintained better by the 2/2 fixation but there is no statistical difference compared to the other fixations. Insertion of screws at the fracture level did not improve outcomes. The data of this study identified a trend towards better radiological outcomes for fracture reduction and maintenance of the correction in the 2/2 fixations. However these results are not statistically significant. Future multicenter prospective clinical trials are needed in order to agree on the ideal management and method of fixation for thoracolumbar fractures.

  3. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    PubMed

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Management of complications of open reduction and internal fixation of ankle fractures.

    PubMed

    Ng, Alan; Barnes, Esther S

    2009-01-01

    The management of complications resulting from the open reduction and internal fixation of ankle fractures is discussed in detail. The initial radiographic findings of the most common postsurgical complications of ankle fracture reduction are briefly discussed, namely lateral, medial, and posterior malleolar malunion or nonunion, syndesmotic widening, degenerative changes, and septic arthritis with or without concomitant osteomyelitis. Emphasis is placed on the management of these complications, with a review of the treatment options proposed in the literature, a detailed discussion of the authors' recommendations, and an inclusion of different case presentations.

  5. Early Weightbearing After Operatively Treated Ankle Fractures: A Biomechanical Analysis.

    PubMed

    Tan, Eric W; Sirisreetreerux, Norachart; Paez, Adrian G; Parks, Brent G; Schon, Lew C; Hasenboehler, Erik A

    2016-06-01

    No consensus exists regarding the timing of weightbearing after surgical fixation of unstable traumatic ankle fractures. We evaluated fracture displacement and timing of displacement with simulated early weightbearing in a cadaveric model. Twenty-four fresh-frozen lower extremities were assigned to Group 1, bimalleolar ankle fracture (n=6); Group 2, trimalleolar ankle fracture with unfixed small posterior malleolar fracture (n=9); or Group 3, trimalleolar ankle fracture with fixed large posterior malleolar fracture (n=9) and tested with axial compressive load at 3 Hz from 0 to 1000 N for 250 000 cycles to simulate 5 weeks of full weightbearing. Displacement was measured by differential variable reluctance transducer. The average motion at all fracture sites in all groups was significantly less than 1 mm (P < .05). Group 1 displacement of the lateral and medial malleolus fracture was 0.1±0.1 mm and 0.4±0.4 mm, respectively. Group 2 displacement of the lateral, medial, and posterior malleolar fracture was 0.6±0.4 mm, 0.5±0.4 mm, and 0.5±0.6 mm, respectively. Group 3 displacement of the lateral, medial, and posterior malleolar fracture was 0.1±0.1 mm, 0.5±0.7 mm, and 0.5±0.4 mm, respectively. The majority of displacement (64.0% to 92.3%) occurred in the first 50 000 cycles. There was no correlation between fracture displacement and bone mineral density. No significant fracture displacement, no hardware failure, and no new fractures occurred in a cadaveric model of early weightbearing in unstable ankle fracture after open reduction and internal fixation. This study supports further investigation of early weightbearing postoperative protocols after fixation of unstable ankle fractures. © The Author(s) 2016.

  6. Rate of avascular necrosis and time to surgery in proximal humerus fractures.

    PubMed

    Archer, L A; Furey, A

    2016-12-01

    Avascular necrosis (AVN) of the humeral head is a devastating complication of proximal humeral fracture (PHF) that often results in long-term morbidity for the patient. Rates of AVN depend on the number of fracture fragments and are highly variable. The literature suggests that timely stable and anatomic reduction may decrease the rate at which AVN develops after PHF. To our knowledge, there is no literature published investigating a temporal relationship between the timing of PHF fixation and rates of AVN. Operative records of one orthopedic trauma surgeon were used to identify patients that underwent open reduction internal fixation for PHF at our institution between 2007 and 2012. Radiographs at presentation were reviewed and used to classify the fractures into two, three or four parts. Date and time of the initial radiograph were recorded as were the date and time of available intra-operative fluoroscopic images. The time from presentation radiograph to operative fixation was calculated (hours). Available follow-up plain films were then reviewed and evaluated for the presence or absence of humeral head AVN. Time to surgery (less than or greater than 72 h) and patient age did not correlate with development of AVN after PHF (p > 0.26). Notably, the number of fracture fragments did influence the rate of AVN identified in patients with PHF (p = 0.002). Early operative intervention does not appear to decrease the rate of development of avascular necrosis after PHF.

  7. Comparison of the technique of anterior cervical distraction and screw elevating-pulling reduction and conventional anterior cervical reduction technique for traumatic cervical spine fractures and dislocations.

    PubMed

    Li, Haoxi; Huang, Yufeng; Cheng, Changzhi; Lin, Zhoudan; Wu, Desheng

    2017-04-01

    To analyze and confirm the advantages of anterior cervical distraction and screw elevating-pulling reduction which are absent in conventional anterior cervical reduction for traumatic cervical spine fractures and dislocations. A retrospective study was conducted on 86 patients with traumatic cervical spine fractures and dislocations who received one-stage anterior approach treatment for a distraction-flexion injury with bilateral locked facet joints between January 2010 and June 2015. They were 54 males and 32 females with an age ranging from 20 to 73 years (average age, 40.1 ± 5.6 years). These patients were distributed into group A and group B in the sequence of visits, with 44 cases of conventional anterior cervical reduction (group A) and 42 cases of anterior cervical distraction and screw elevating-pulling reduction (group B). Comparison of intraoperative blood loss, operation duration and vertebral reduction rate was made between the two groups. The follow-up time was 12-18 months, and the clinical outcomes of surgery were evaluated according to ASIA score, VAS score and JOA score. Statistically significant difference was revealed between group A and group B in the surgical time and the correction rate of cervical spine dislocation (p < 0.05), with the results of group B better than those of group A. For the two groups, statistically significant difference was shown between the ASIA score, VAS score and JOA score before and after operation (p < 0.05), with the results better after operation, while no statistically significant difference was revealed in such scores between the two groups (p > 0.05), with the therapeutic effect of group A the same with that of group B. Anterior cervical distraction and screw elevating-pulling reduction is simple with low risk, short operation duration, good effect of intraoperative vertebral reduction and well-recovered function after the operation. Meanwhile, as a safe and effective operation method for cervical spine fractures and dislocations, it can reduce postoperative complications and the risk of the iatrogenic cervical spinal cord injury caused by prying or facet joint springing during conventional reduction, having more obvious advantages compared to the conventional surgical reduction adopted by group A, with good cervical spine stability as shown in long-term follow-up. Therefore, it is suitable for clinical promotion and application. Copyright © 2017. Published by Elsevier Ltd.

  8. Accuracy of specimen-specific nonlinear finite element analysis for evaluation of radial diaphysis strength in cadaver material.

    PubMed

    Matsuura, Yusuke; Kuniyoshi, Kazuki; Suzuki, Takane; Ogawa, Yasufumi; Sukegawa, Koji; Rokkaku, Tomoyuki; Thoreson, Andrew Ryan; An, Kai-Nan; Takahashi, Kazuhisa

    2015-01-01

    The feasibility of a user-specific finite element model for predicting the in situ strength of the radius after implantation of bone plates for open fracture reduction was established. The effect of metal artifact in CT imaging was characterized. The results were verified against biomechanical test data. Fourteen cadaveric radii were divided into two groups: (1) intact radii for evaluating the accuracy of radial diaphysis strength predictions with finite element analysis and (2) radii with a locking plate affixed for evaluating metal artifact. All bones were imaged with CT. In the plated group, radii were first imaged with the plates affixed (for simulating digital plate removal). They were then subsequently imaged with the locking plates and screws removed (actual plate removal). Fracture strength of the radius diaphysis under axial compression was predicted with a three-dimensional, specimen-specific, nonlinear finite element analysis for both the intact and plated bones (bones with and without the plate captured in the scan). Specimens were then loaded to failure using a universal testing machine to verify the actual fracture load. In the intact group, the physical and predicted fracture loads were strongly correlated. For radii with plates affixed, the physical and predicted (simulated plate removal and actual plate removal) fracture loads were strongly correlated. This study demonstrates that our specimen-specific finite element analysis can accurately predict the strength of the radial diaphysis. The metal artifact from CT imaging was shown to produce an overestimate of strength.

  9. Fractures of the capitellum--a comparison of two fixation methods.

    PubMed

    Poynton, A R; Kelly, I P; O'Rourke, S K

    1998-06-01

    Isolated capitellar fractures are rare, accounting for only 1 per cent of all elbow fractures (Bryan and Morrey, The Elbow and its Disorders, 1985). Many different fixation methods have been described but no series has compared these treatment modalities because of the rarity of these fractures. This paper compares the outcome of two types of fixation of type I capitellar fractures. Group one (n = 6) had open reduction and Kirschner wire fixation while group two (n = 6) had open reduction and Herbert screw fixation. Both groups were compared clinically, functionally and radiographically. We found that Herbert screw fixation enabled earlier mobilization and a better functional outcome.

  10. Fractures of the Talus: State of the Art.

    PubMed

    Vallier, Heather A

    2015-09-01

    Talus fractures occur rarely but are often associated with complications and functional limitations. Urgent reduction of associated dislocations is recommended with open reduction and internal fixation of displaced fractures when adjacent soft tissue injury permits. Delayed definitive fixation may reduce the risks of wound complications and infections. Restoration of articular and axial alignment is necessary to optimize ankle and hindfoot function. Despite this, posttraumatic arthrosis occurs frequently after talar neck and body fractures, especially with comminution of the talar body. Osteonecrosis is reported in up to half of talar neck fractures, although many of these injuries will revascularize without collapse of the talar dome. Initial fracture displacement and presence of open fractures increase the risk of osteonecrosis. Talar process fractures may be subtle and easily missed on plain radiographs. Advanced imaging will provide detail to facilitate treatment planning. Therapeutic Level V. See Instructions for Authors for a complete description of levels of evidence.

  11. The cost effectiveness of teriparatide as a first-line treatment for glucocorticoid-induced and postmenopausal osteoporosis patients in Sweden.

    PubMed

    Murphy, Daniel R; Smolen, Lee J; Klein, Timothy M; Klein, Robert W

    2012-10-30

    This paper presents the model and results to evaluate the use of teriparatide as a first-line treatment of severe postmenopausal osteoporosis (PMO) and glucocorticoid-induced osteoporosis (GIOP). The study's objective was to determine if teriparatide is cost effective against oral bisphosphonates for two large and high risk cohorts. A computer simulation model was created to model treatment, osteoporosis related fractures, and the remaining life of PMO and GIOP patients. Natural mortality and additional mortality from osteoporosis related fractures were included in the model. Costs for treatment with both teriparatide and oral bisphosphonates were included. Drug efficacy was modeled as a reduction to the relative fracture risk for subsequent osteoporosis related fractures. Patient health utilities associated with age, gender, and osteoporosis related fractures were included in the model. Patient costs and utilities were summarized and incremental cost-effectiveness ratios (ICERs) for teriparatide versus oral bisphosphonates and teriparatide versus no treatment were estimated.For each of the PMO and GIOP populations, two cohorts differentiated by fracture history were simulated. The first contained patients with both a historical vertebral fracture and an incident vertebral fracture. The second contained patients with only an incident vertebral fracture. The PMO cohorts simulated had an initial Bone Mineral Density (BMD) T-Score of -3.0. The GIOP cohorts simulated had an initial BMD T-Score of -2.5. The ICERs for teriparatide versus bisphosphonate use for the one and two fracture PMO cohorts were €36,995 per QALY and €19,371 per QALY. The ICERs for teriparatide versus bisphosphonate use for the one and two fracture GIOP cohorts were €20,826 per QALY and €15,155 per QALY, respectively. The selection of teriparatide versus oral bisphosphonates as a first-line treatment for the high risk PMO and GIOP cohorts evaluated is justified at a cost per QALY threshold of €50,000.

  12. Closed reduction of displaced or dislocated mandibular condyle fractures in children using threaded Kirschner wire and external rubber traction.

    PubMed

    Kim, J H; Nam, D H

    2015-10-01

    Most surgeons agree that closed treatment provides the best results for condylar fractures in children. Nevertheless, treatment of the paediatric mandibular condyle fracture that is severely displaced or dislocated is controversial. The purpose of this study was to investigate the long-term clinical and radiological outcomes following the treatment of displaced or dislocated condylar fractures in children using threaded Kirschner wire and external rubber traction. This procedure can strengthen the advantage of closed reduction and make up for the shortcomings of open reduction. From March 1, 2005 to December 25, 2011, 11 children aged between 4 and 12 years with displaced or dislocated mandibular condyle fractures were treated using threaded Kirschner wire and external rubber traction under portable C-arm fluoroscopy. All patients had unilateral displaced or dislocated condylar fractures. The follow-up period ranged from 24 to 42 months (mean 29.3 months). Normal occlusion and pain-free function of the temporomandibular joint, without deviation or limitation of jaw opening, was achieved in all patients. This closed reduction technique in displaced or dislocated condylar fractures in children offers a reliable solution in preventing the unfavourable sequelae of closed treatment and the open technique, such as altered morphology, functional disturbances, and facial nerve damage. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Fracture toughness testing of polymer matrix composites

    NASA Technical Reports Server (NTRS)

    Grady, Joseph E.

    1992-01-01

    A review of the interlaminar fracture indicates that a standard specimen geometry is needed to obtain consistent fracture toughness measurements in polymer matrix composites. In general, the variability of measured toughness values increases as the toughness of the material increases. This variability could be caused by incorrect sizing of test specimens and/or inconsistent data reduction procedures. A standard data reduction procedure is therefore needed as well, particularly for the tougher materials. Little work has been reported on the effects of fiber orientation, fiber architecture, fiber surface treatment or interlaminar fracture toughness, and the mechanisms by which the fibers increase fracture toughness are not well understood. The little data that is available indicates that woven fiber reinforcement and fiber sizings can significantly increase interlaminar fracture toughness.

  14. A prospective study on the effectiveness of cotton versus waterproof cast padding in maintaining the reduction of pediatric distal forearm fractures.

    PubMed

    Robert, Christopher E; Jiang, Jimmy J; Khoury, Joseph G

    2011-03-01

    Distal forearm fractures, one of the most common fractures seen in the pediatric population, are regularly treated by closed reduction and casting. Our study investigates the effectiveness of Gore-Tex-lined casting in maintaining the reduction of 100% displaced distal forearm fractures compared with traditional cotton-lined casts. We screened all patients from February 2007 to July 2009 who presented to Children's Hospital in Birmingham, AL with a distal radius fracture. Only patients with 100% displaced distal radius fractures were eligible to be assigned to either the cotton-lined or Gore-Tex-lined cast groups. Power analysis was performed to identify an adequate patient sample size. The mean maximum change between initial post-reduction x-rays and follow-up x-rays for anterior-posterior (AP) angulation, AP displacement, lateral angulation, and lateral displacement of the radius were calculated for both cotton and Gore-Tex groups. The rate of subsequent intervention and/or unacceptable results for each group was also analyzed. Seven hundred and twenty-two patients were treated with distal radius fractures at our hospital with 59 patients eligible for inclusion in our study. Thirty-six of our patients were treated with cotton-lined casts, and 23 patients were treated with Gore-Tex-lined cast. The mean maximum change in AP angulation, AP displacement, lateral angulation, and lateral displacement of the radius after initial reduction was 9.2 degrees, 6.9%, 13.9 degrees, and 13.6%, respectively, for the cotton-lined cast group and 7.7 degrees, 6.1%, 14.6 degrees, and 9.6%, respectively, for the Gore-Tex-lined cast group. There were no statistical differences between the means of the 4 measurements (P=0.33, 0.69, 0.73, and 0.10, respectively). There were also no significant differences between groups for final AP and lateral angulation and displacement. Subgroup analysis showed no significant differences in all measurements between cotton and Gore-Tex groups. Gore-Tex and cotton-lined casts are equally effective in their ability to maintain the reduction of 100% displaced distal forearm fractures. Thus, Gore-Tex-lined casts can be offered to pediatric patients immediately after closed reduction of distal radius fractures of any severity. Therapeutic level II.

  15. Fracture resistance of metal-free composite crowns-effects of fiber reinforcement, thermal cycling, and cementation technique.

    PubMed

    Lehmann, Franziska; Eickemeyer, Grit; Rammelsberg, Peter

    2004-09-01

    The improved mechanical properties of contemporary composites have resulted in their extensive use for the restoration of posterior teeth. However, the influence of fiber reinforcement, cementation technique, and physical stress on the fracture resistance of metal-free crowns is unknown. This in vitro study evaluated the effect of fiber reinforcement, physical stress, and cementation methods on the fracture resistance of posterior metal-free Sinfony crowns. Ninety-six extracted human third molars received a standardized tooth preparation: 0.5-mm chamfer preparation and occlusal reduction of 1.3 to 1.5 mm. Sinfony (nonreinforced crowns, n=48) and Sinfony-Vectris (reinforced crowns, n=48) crowns restoring original tooth contour were prepared. Twenty-four specimens of each crown type were cemented, using either glass ionomer cement (GIC) or resin cement. Thirty-two crowns (one third) were stored in humidity for 48 hours. Another third was exposed to 10,000 thermal cycles (TC) between 5 degrees C and 55 degrees C. The remaining third was treated with thermal cycling and mechanical loading (TCML), consisting of 1.2 million axial loads of 50 N. The artificial crowns were then vertically loaded with a steel sphere until failure occurred. Significant differences in fracture resistance (N) between experimental groups were assessed by nonparametric Mann-Whitney U-test (alpha=.05). Fifty percent of the Sinfony and Sinfony-Vectris crowns cemented with glass ionomer cement loosened after thermal cycling. Thermal cycling resulted in a significant reduction in the mean fracture resistance for Sinfony crowns cemented with GIC, from 2037 N to 1282 N (P=.004). Additional fatigue produced no further effects. Fiber reinforcement significantly increased fracture resistance, from 1555 N to 2326 N (P=.001). The minimal fracture resistance was above 600 N for all combinations of material, cement and loading. Fracture resistance of metal-free Sinfony crowns was significantly increased by fiber reinforcement. Adhesive cementation may be recommended to avoid cementation failure.

  16. Shaft-Condylar Angle for surgical correction in neglected and displaced lateral humeral condyle fracture in children.

    PubMed

    Mulpruek, Pornchai; Angsanuntsukh, Chanika; Woratanarat, Patarawan; Sa-Ngasoongsong, Paphon; Tawonsawatruk, Tulyapruek; Chanplakorn, Pongsthorn

    2015-09-01

    To assess the outcome after using the Shaft-Condylar angle (SCA) as intraoperative reference for sagittal plane correction in displaced lateral humeral condyle fractures in children presented 3-weeks after injury. Ten children, with delayed presentation of a displaced lateral humeral condyle fracture and undergoing surgery during 1999-2011, were reviewed. The goal was to obtain a smooth articular surface with an intraoperative SCA of nearly 40° and nearest-anatomical carrying angle. They were allocated into two groups according to the postoperative SCA [Good-reduction group (SCA=30-50°), and Bad-reduction group (SCA<30°, >50°)] and the final outcomes were then compared. All fractures united without avascular necrosis. The Good-reduction group (n=7) showed a significant improvement in final range of motion and functional outcome compared to the Bad-reduction group (n=3) (p=0.02). However, there was no significant difference in pain, carrying angle and overall outcome between both groups. SCA is a possible intraoperative reference for sagittal alignment correction in late presented displaced lateral humeral condyle fractures.

  17. Investigation of high temperature fracture of T-111 and ASTAR-811C

    NASA Technical Reports Server (NTRS)

    Gold, R. E.

    1971-01-01

    The high temperature deformation and fracture behavior of T-111 and ASTAR-811C were studied over the temperature range 982 to 2205 C (1800 to 4000 F). As-cast and wrought-recrystallized material as well as GTA welds in sheet and plate were evaluated using conventional tensile and creep tests. Post test examinations were performed using optical metallography, scanning electron microscopy and transmission electron microscopy. A high temperature region of reduced ductility, in terms of tensile elongation, was identified for both alloys. The reduction in tensile elongation became more severe with increase in grain size, being near catastrophic for the as-cast specimens. Optical and electron metallography indicated that even for failures at very low total strain, considerable deformation of a very localized nature had occurred prior to fracture.

  18. Base of coracoid process fracture with acromioclavicular dislocation in a child

    PubMed Central

    2010-01-01

    Fracture of the coracoid process is a rare injury. It can be easily missed when associated with other injuries to the shoulder girdle, for instance, acromioclavicular joint (ACJ) dislocation. Clinical attention is easily drawn to the more obvious ACJ dislocation, hence, the need for further radiological evaluation. We report an unusual case of fracture of the base of coracoid process associated with a true acromioclavicular joint dislocation in a 12 year old boy, with no separation of the epiphyseal plate, as one might expect. Treatment also remains controversial. Our patient underwent open reduction internal fixation of the acromioclavicular joint and coracoid process. He subsequently made an uneventful progress with pain free full range of shoulder movement at 5 months, and was discharged at 9 months. PMID:20955595

  19. Incorporating Scale-Dependent Fracture Stiffness for Improved Reservoir Performance Prediction

    NASA Astrophysics Data System (ADS)

    Crawford, B. R.; Tsenn, M. C.; Homburg, J. M.; Stehle, R. C.; Freysteinson, J. A.; Reese, W. C.

    2017-12-01

    We present a novel technique for predicting dynamic fracture network response to production-driven changes in effective stress, with the potential for optimizing depletion planning and improving recovery prediction in stress-sensitive naturally fractured reservoirs. A key component of the method involves laboratory geomechanics testing of single fractures in order to develop a unique scaling relationship between fracture normal stiffness and initial mechanical aperture. Details of the workflow are as follows: tensile, opening mode fractures are created in a variety of low matrix permeability rocks with initial, unstressed apertures in the micrometer to millimeter range, as determined from image analyses of X-ray CT scans; subsequent hydrostatic compression of these fractured samples with synchronous radial strain and flow measurement indicates that both mechanical and hydraulic aperture reduction varies linearly with the natural logarithm of effective normal stress; these stress-sensitive single-fracture laboratory observations are then upscaled to networks with fracture populations displaying frequency-length and length-aperture scaling laws commonly exhibited by natural fracture arrays; functional relationships between reservoir pressure reduction and fracture network porosity, compressibility and directional permeabilities as generated by such discrete fracture network modeling are then exported to the reservoir simulator for improved naturally fractured reservoir performance prediction.

  20. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  1. Management of comminuted but continuous mandible defects after gunshot injuries.

    PubMed

    Rana, Majeed; Warraich, Riaz; Rashad, Ashkan; von See, Constantin; Channar, Kashif A; Rana, Madiha; Stoetzer, Marcus; Gellrich, Nils-Claudius

    2014-01-01

    Firearm injuries continue as a major public health problem, contributing significant morbidity, mortality, and expense to our society. There are four main steps in the management of patients with gunshot wounds to the face: securing an airway, controlling haemorrhage, identifying other injuries and definitive repair of the traumatic facial deformities. The objective of this study was to determine late outcome of two treatment options by open reduction and internal fixation versus closed reduction and maxillomandibular fixation (MMF) in the treatment of gunshot injuries of the mandible. Sixty patients of gunshot injury were randomly allocated in two groups. In group A, 30 patients were treated by open reduction and internal fixation and in group B, 30 patients were treated by closed reduction and maxillomandibular fixation. Patients were discharged as the treatment completed and recalled for follow up. Up to 3 months after injury, fortnightly complications like infection, malocclusion, malunion of fractured fragments, facial asymmetry, sequestration of bone and exposed plates were evaluated and the differences between two groups were assessed. The follow-up period ranged from 3 months to 10 months. Patients treated by open reduction tended to have less complications as compared to closed reduction. Based on this study open reduction and internal fixation is the best available method for the treatment of gunshot mandible fractures without continuity defect. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. [Role of radiotherapy in the treatment of multiple myeloma].

    PubMed

    Mose, S; Pfitzner, D; Rahn, A; Nierhoff, C; Schiemann, M; Böttcher, H D

    2000-11-01

    Chemotherapy is the treatment of choice in multiple myeloma; but there are no curative options. Therefore, the treatment rationale is characterized by reduction of symptoms and inhibition of complications. Regarding reduction of pain, treatment of (impending) fractures, and spinal cord compression radiation is an important part of palliative treatment. In our retrospective study we report the effect of radiotherapy on reduction of pain, recalcification and the reduction of neurological symptoms and evaluate factors which have an impact on therapeutic outcome. From 1, Jan 1988 to 31, Dec 1998, 42 patients (19 women, 23 men; range of ages 46 to 85 years, median age 64.9 years) with 71 target volumes were irradiated (median dose 36 Gy, 2 to 3 Gy 5 times/week) because of symptomatic disease (67/71: osseous pain, 45/71: fractures/impending fractures, 13/71: spinal cord compression) (Tables 1 and 2). The median time from diagnosis to the first course of radiotherapy was 11.9 months (0.3 to 90 months). At the time of first irradiation, 5 and 37 patients were in tumor Stage II and III (Salmon/Durie), respectively. The median value of the Karnofsky performance was 70% (40 to 90%). During follow-up (at least 6 months) in 85% of target volumes complete and partial pain relief (measured by patients' perception and the use of analgetic medication) was achieved; recurrences were seen in 8.8%. In 26/56 (46.4%) lesions evaluable a recalcification was seen whereas 17.9% showed progressive disease (comparison of radiographs before and after radiation). In 22.3% of all lesions initially with impending fracture (4/18) radiotherapy failed because of fracture after treatment (Tables 3 and 4). Simultaneous chemotherapy and a Karnofsky performance > or = 70 had a significant impact on a positive response to treatment, respectively. Spinal cord compression symptoms were reduced in 7/13 (53.8%) of patients (scaled due to the classification by Findlay 1987). The median survival from diagnosis for the entire group was 34.9 months (7.5 to 119.3 months), after irradiation 13.1 months (0.2 to 105.3 months) (Figure 1). When adequately indicated radiotherapy has shown to be an effective palliative treatment. Taking under consideration that the results are retrospective we suppose that in multiple myeloma the local response to radiation is supported by a favorable performance status and simultaneous chemotherapy. Irradiation treatment does not change prognosis regarding overall survival.

  3. Classification of intertrochanteric fractures with computed tomography: a study of intraobserver and interobserver variability and prognostic value.

    PubMed

    Chapman, Cary B; Herrera, Mauricio F; Binenbaum, Gil; Schweppe, Michael; Staron, Ronald B; Feldman, Frieda; Rosenwasser, Melvin P

    2003-09-01

    The purpose of this prospective study was to determine the level of interobserver and intraobserver agreement among orthopedic surgeons and radiologists when computed tomography (CT) scans are used with plain radiographs to evaluate intertrochanteric fractures. In addition, the prognostic value of current classifications systems concerning quality of life was evaluated. Sixty-one patients who presented with intertrochanteric fractures received open reduction and internal fixation with compression hip screw. Three orthopedic surgeons and 2 radiologists independently classified the fractures according to 2 systems: Evans-Jensen and AO (Arbeitsgemeinschaft für Osteo-synthesefragen). Fractures were initially graded with plain radiographs and then again in conjunction with CT. Results were analyzed using the (kappa) kappa coefficient. The 36-item Short-Form Health Survey was administered at baseline, 3 months, and 1 year, and results were correlated with fracture grade. Mean kappa coefficients when comparing radiography alone with radiography and CT scan were 0.63 for the AO system and 0.59 for the Evans-Jensen system. Both represent "fair" agreements. Mean overall interobserver kappa coefficients were 0.67 for radiologists and 0.57 for orthopedic surgeons. Radiologists also had higher intraobserver kappa coefficients. No significant relationships were found between follow-up Short Form Health Survey results and intraoperative grading of fractures. When these classification schemes are compared, interobserver agreement does not appear to change dramatically when information from CT scans is added. This may suggest that (1) more data have been provided by CT with greater possibilities for misinterpretation and (2) these classification schemes may not be comprehensive in describing fracture pattern and displacement. Finally, both systems failed to provide any prognostic value.

  4. A 3-dimensional-printed patient-specific guide system for minimally invasive plate osteosynthesis of a comminuted mid-diaphyseal humeral fracture in a cat.

    PubMed

    Oxley, Bill

    2018-04-01

    To report the use of a 3-dimensional (3D)-printed patient-specific reduction guide system to facilitate minimally invasive plate osteosynthesis (MIPO) of a humeral fracture in a cat. Case report. A 9-year-old male neutered domestic short hair cat weighing 4.4 kg. A 9-year-old male domestic short hair cat was presented with a comminuted, mid-diaphyseal left humeral fracture. Computed tomographic data were processed to yield 3D mesh representations of both humeri and subsequently manipulated in computer-aided design software. The mirrored, intact humerus was used as a template for appropriate spatial orientation of the major proximal and distal fracture fragments. Patient-specific Ellis pin orientation guides and a reduction guide were designed and 3D printed. The guide system was used intraoperatively to align the major fracture fragments before application of locking internal fixation via standard MIPO surgical portals. Internal fixation of the fracture resulted in appropriate bone alignment. Recovery was uncomplicated, with early return to normal limb function and radiographic evidence of advanced fracture healing after 4 months. A 3D-printed patient-specific reduction guide system facilitated accurate alignment of a comminuted humeral fracture during MIPO without intraoperative imaging. © 2018 The American College of Veterinary Surgeons.

  5. [Intramedullary nailing of the tibia with the expert tibia nail].

    PubMed

    Hansen, Matthias; El Attal, René; Blum, Jochen; Blauth, Michael; Rommens, Pol Maria

    2009-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare. Early functional aftercare to maintain joint mobility. Good bony healing in closed and open fractures. All closed and open fractures of the tibia and complete lower leg fractures (AO 42). Certain extraarticular fractures of the proximal and distal tibia (AO 41 A2/A3; AO 43 A1/A2/A3). Segmental fractures of the tibia. Certain intraarticular fractures of the tibia with use of additional implants (AO 41 C1/C2; AO 43 C1/C2). Stabilization during and after segmental bone transport or callus distraction of the tibia. Patients in poor general condition (e.g., bedridden). Flexion of the knee of less than 90 degrees . Infection in the nail's insertion area. Infection of the tibial cavity. Complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture. If necessary, use of reduction clamps through additional stab incisions or open surgical procedures. In some cases, additional osteosynthesis procedures are necessary (e.g., screws). Positioning of the patient may be performed on a radiolucent table or a traction table. Opening of the proximal tibia in line with the medullary canal. Cannulated or noncannulated insertion of the Expert Tibia Nail((R)) with or without reaming of the medullary canal depending on the fracture type and soft-tissue condition. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle joint and knee joint. Depending on the type of fracture, mobilization with 20 kg partial weight bearing or pain-dependent full weight bearing with crutches. X-ray control 6 weeks postoperatively and increased weight bearing depending on the fracture status. In a prospective, international multicentric study, 181 patients with 186 fractures were included between July 2004 and May 2005. 57 of these fractures (30.7%) initially were graded open, 15 of them grade I, 32 grade II, and ten grade III. Most of the fractures (36%) were shaft fractures. After 1 year, 146 patients (81%) could be evaluated clinically and radiologically. The overall pseudarthrosis rate was 12.2% (18.2% for open and 9.7% for closed fractures). The risk for secondary operations or revisions (including dynamization of the nail) was 18.8%. Without consideration of dynamization procedures, revisions were necessary in only 5.4% of all patients. The risk for varus, valgus or antecurvation malalignment of more than 5 degrees in any plane on radiologic long leg views was 4.3% for shaft fractures, 1.5% for distal fractures, and 13.6% for proximal fractures. The implant-specific risk for bolt breakage was 3.2%.

  6. Reduction of Zygomatic Fractures Using the Carroll-Girard T-bar Screw.

    PubMed

    Baek, Ji Eun; Chung, Chan Min; Hong, In Pyo

    2012-09-01

    Zygomatic fractures are the second most common facial bone fractures encountered and treated by plastic surgeons. Stable fixation of fractured fragments after adequate exposure is critical for ensuring three-dimensional anatomic reduction. Between January 2008 and December 2010, 17 patients with zygomatic fractures were admitted to our hospital; there were 15 male and 2 female patients. The average age of the patients was 41 years (range, 19 to 75 years). We exposed the inferior orbital rim and zygomatic complex through a lateral brow, intraoral, and subciliary incisions, which allowed for visualization of the bone, and then the fractured parts were corrected using the Carroll-Girard T-bar screw. Postoperative complications such as malar asymmetry, diplopia, enophthalmos, and postoperative infection were not observed. Lower eyelid retraction and temporary ectropion occurred in 1 of the 17 patients. Functional and cosmetic results were excellent in nearly all of the cases. In this report, we describe using the Carroll-Girard T-bar screw for the reduction of zygomatic fractures. Because this instrument is easy to use and can rotate to any direction and vector, it can be used to correct displaced zygomatic bone more accurately and safely than other devices, without leaving facial scars.

  7. Management of maxillofacial injuries in Iraq.

    PubMed

    Kummoona, Raja

    2011-09-01

    These clinical studies reflect the experience of the author in managing 673 patients treated during the last 8 years. All patients were treated in the Maxillofacial Unit, Surgical Specialties Hospital, Medical City, Baghdad, and in the author's private clinic. Included patients were 530 males and 143 females; patients' age ranged between 1 year and 75 years (mean, 38 y). Distribution of injuries was as follows: fracture of the mandible, 287 (42.64%); middle third injuries, 39 (5.79%); orbital injuries, 236 (35.07%; including 12 cases with cranioorbital injuries); injuries in children, 27 (4.0%); fracture of the zygoma, 52 (7.73%); and fracture of the nose, 40 (5.94%).Maxillofacial injuries in this study were classified as follows: (1) craniomaxillofacial with head injuries and cerebrospinal fluid leak; (2) fracture of the middle third including Le Fort I, II, and III and midline split in the face; (3) fracture of the mandible as an isolated injury or as part of a facial skeleton injury; and (4) isolated complex injuries of the zygoma, the orbital skeleton, and the nasoethmoidal region.The technique used for treating middle third injuries was external fixation either by halo frame (with vertical rods and cheek wires) or by box frame (using 4 external pins connected by rods) or internal fixation by suspending the middle third with internal wires (0.5 mm stainless steel) from the zygomatic process of the frontal bone beneath the zygomatic arch down the lower arch bar. Fractures of the mandible were treated by gunning splint with intermaxillary fixation (IMF) or with open reduction and fixation by stainless steel wire with IMF or by IMF screw or by an arch bar and IMF. Other fractures such as fracture of the orbit were treated by bone graft, sialastic, or lyophilized dura with open reduction. Fractures of the zygoma were treated by open reduction and fixation with stainless steel wire and bone graft or by reduction without fixation. Fractures of the nose were treated by reduction with straightening of the septum with a splint (lead splint or polythene) or by external splint with plaster of Paris. With the techniques used, results from managing these cases were satisfactory.

  8. DEMONSTRATION BULLETIN: HYDRAULIC FRACTURING OF CONTAMINATED SOIL

    EPA Science Inventory

    Hydraulic fracturing is a physical process that creates fractures in silty clay soil to enhance its permeability. The technology, developed by the Risk Reduction Engineering Laboratory (RREL) and the University of Cincinnati, creates sand-filled horizontal fractures up to 1 in. i...

  9. [Treatment of linguiform calcaneus fracture by close nail-pry reduction and internal fixation with hollow screws].

    PubMed

    Tu, Shu-Qiang; Huang, Ke-Di; Shuai, Yong-Ming; Xu, Nan-Yun; Yuan, Qiu-Wen; Guo, Jian

    2012-06-01

    To study the curative effects of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture. From May 2006 to October 2009,32 patients (35 feet) with linguiform calcaneus fracture were treated by close nail-pry reduction and internal fixation with hollow screws, including 23 males and 9 females ranging in age from 25 to 46 years, with a mean of 37.6 years. According to Paley classification, 3 cases were Paley II a, and 29 cases were Paley II b. All cases were close fractures. The time from injury to operation was 3 to 10 days after most swelling subsided. Böhler angle and Gissane angle were measured by X-ray before and after operation. The therapeutic effect was assessed according to ZHANG Tie-liang's foot score. All the patients were followed-up for 6 to 18 months, with a mean of 12 months. All fractures gained bone healing. The time of fracture healing averaged 12 months. The fractures healed completely and no infection occurred. According to ZHANG Tie-liang's foot scale, the postoperative function was excellent in 18 feet, good in 10 feet, moderate in 5 feet and poor in 2 feet. The Böhler angle and Gissane angle were significant improved after treatment (P < 0.01). The surgical method of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture can regain the foot function, with minimal injury, fewer complications, earlier recovery and lower costs.

  10. Allgöwer-Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography.

    PubMed

    Shannon, Steven F; Houdek, Matthew T; Wyles, Cody C; Yuan, Brandon J; Cross, William W; Cass, Joseph R; Sems, Stephen A

    2017-02-01

    The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allgöwer-Donati or vertical mattress. Prospective, randomized. Level 1 Academic Trauma Center. Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allgöwer-Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA/AO fracture classification. Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months. Allgöwer-Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allgöwer-Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, P < 0.0001). Mean perfusion impairment was less in the Allgöwer-Donati cohort (12.8, SD = 9) compared with that in the vertical mattress cohort (23.4, SD = 14; P = 0.03). One patient in each cohort experienced a wound complication. The Allgöwer-Donati suture technique offers improved incision perfusion compared with vertical mattress closure after open reduction internal fixation of ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  11. Fixed-angle plates in patella fractures - a pilot cadaver study

    PubMed Central

    2011-01-01

    Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years) a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge), quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65). Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays advantages over the established operative procedures. PMID:21345769

  12. The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures

    PubMed Central

    Ma, Junli; Ma, Limin; Wang, Zhifa; Zhu, Xiongjie; Wang, Weijian

    2017-01-01

    Abstract Rationale: Precise bony reduction and reconstruction of optimal contour in treating comminuted mandibular fractures is very difficult using traditional techniques and devices. The aim of this report is to introduce our experiences in using virtual surgery and three-dimensional (3D) printing technique in treating this clinical challenge. Patient concerns: A 26-year-old man presented with severe trauma in the maxillofacial area due to fall from height. Diagnosis: Computed tomography images revealed middle face fractures and comminuted mandibular fracture including bilateral condyles. Interventions and outcomes: The computed tomography data was used to construct the 3D cranio-maxillofacial models; then the displaced bone fragments were virtually reduced. On the basis of the finalized model, a customized titanium mesh tray was designed and fabricated using selective laser melting technology. During the surgery, a submandibular approach was adopted to repair the mandibular fracture. The reduction and fixation were performed according to preoperative plan, the bone defects in the mental area were reconstructed with iliac bone graft. The 3D-printed mesh tray served as an intraoperative template and carrier of bone graft. The healing process was uneventful, and the patient was satisfied with the mandible contour. Lessons: Virtual surgical planning combined with 3D printing technology enables surgeon to visualize the reduction process preoperatively and guide intraoperative reduction, making the reduction less time consuming and more precise. 3D-printed titanium mesh tray can provide more satisfactory esthetic outcomes in treating complex comminuted mandibular fractures. PMID:28682875

  13. The effect of repeated torque in small diameter implants with machined and premachined abutments.

    PubMed

    Saboury, Abolfazl; Neshandar Asli, Hamid; Vaziri, Shahram

    2012-05-01

    Detorquing value is an important factor in the amount of preload stresses during abutment screw fastening. This study evaluated the percentage of detorque values in two-piece machined titanium and premachined cast abutments in small diameter implants. Three groups of five samples were evaluated. Group 1 (G1), machined titanium abutments, group 2 (G2), premachined cast straight abutments that cast with gold-palladium, and group 3 (G3), premachined angled cast abutments that cast with the same alloy, were angled before casting. Each abutment was torque to 24 Ncm according to the manufacturer's instructions and detorqued five times. The means of detorquing and torquing values in all groups were recorded. The mean of detorque in each group as a percentage of the toque value was calculated. The data for all groups were compared and calculated using analysis of variance (ANOVA) and t-test. Mean detorque values in G1, G2, and G3 were 88.1 ± 1.69, 93.1 ± 2.68, and 80.9 ± 4.95%, respectively. The ANOVA showed significant differences in mean of applied detorque (p < .001) and torque (p = .06) tightening among different groups. G2 had significantly greater detorque values (p < .05). No significant differences were found between G1 and G2. Surprisingly, abutment screw fracture occurred in three samples of G3. G3 showed significant percentage torque reduction (p < .05) and exhibited abutment screw fracture during evaluation. G2 presented the lowest torque reduction. Screw fracture occurred only in G3. © 2012 Wiley Periodicals, Inc.

  14. Elastic nailing of tibia shaft fractures in young children up to 10 years of age.

    PubMed

    Heo, Jeong; Oh, Chang-Wug; Park, Kyeong-Hyeon; Kim, Joon-Woo; Kim, Hee-June; Lee, Jong-Chul; Park, Il-Hyung

    2016-04-01

    Although tibia shaft fractures in children usually have satisfactory results after closed reduction and casting, there are several surgical indications, including associated fractures and soft tissue injuries such as open fractures. Titanium elastic nails (TENs) are often used for pediatric tibia fractures, and have the advantage of preserving the open physis. However, complications such as delayed union or nonunion are not uncommon in older children or open fractures. In the present study, we evaluated children up to 10 years of age with closed or open tibial shaft fractures treated with elastic nailing technique. A total of 16 tibia shaft fractures treated by elastic nailing from 2001 to 2013 were reviewed. The mean patient age at operation was 7 years (range: 5-10 years). Thirteen of 16 cases were open fractures (grade I: 4, grade II: 6, grade IIIA: 3 cases); the other cases had associated fractures that necessitated operative treatments. Closed, antegrade intramedullary nailing was used to insert two nails through the proximal tibial metaphysis. All patients were followed up for at least one year after the injury. Outcomes were evaluated using modified Flynn's criteria, including union, alignment, leg length discrepancies, and complications. All fractures achieved union a mean of 16.1 weeks after surgery (range: 11-26 weeks). No patient reported knee pain or experienced any loss of knee or ankle motion. There was a case of superficial infection in a patient with grade III open fracture. Three patients reported soft tissue discomfort due to prominent TEN tips at the proximal insertion site, which required cutting the tip before union or removing the nail after union. At the last follow-up, there were no angular or rotational deformities over 10° in either the sagittal or coronal planes. With the exception of one case with an overgrowth of 15 mm, no patient showed shortening or overgrowth exceeding 10mm. Among final outcomes, 15 were excellent and 1 was satisfactory. Even with open fractures or soft tissue injuries, elastic nailing can achieve satisfactory results in young children, with minimal complications of delayed bone healing, or infection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Effect of hydrogen on void initiation in tensile test of carbon steel JIS-S25C

    NASA Astrophysics Data System (ADS)

    Sugawa, S.; Tsutsumi, N.; Oda, K.

    2018-06-01

    In order to investigate the effect of hydrogen on tensile fracture mechanism of a carbon steel, tensile tests were conducted. Pre-strain specimens (0%, 5% and 10%) were used to study the effect of hydrogen content, since saturated hydrogen content in specimens increases in increasing dislocation density. The tensile strength and the yield stress of hydrogen specimens were almost the same as uncharged. In contrast, the reduction of area of hydrogen charged specimens was smaller than that of uncharged. To reveal the reasons of decrease of the reduction of area, the fracture surface and longitudinal cross section near the fracture surface were observed. On the fracture surface of uncharged specimens, only dimples were observed. On the other hand, dimples and flat fracture surface were observed on the fracture surface of hydrogen charged. On the longitudinal cross section of hydrogen charged specimens, many voids were observed compared to uncharged. From these observations, it is showed that hydrogen gives a rise to the increase of voids and the hydrogen charged specimens break without sufficient necking, thus hydrogen makes the reduction of area smaller.

  16. Male osteoporosis: clinical approach and management in family practice

    PubMed Central

    Goh, Lay Hoon; How, Choon How; Lau, Tang Ching

    2014-01-01

    In Singapore, male osteoporosis is gaining greater importance due to our ageing population. Family physicians should screen for osteoporosis in elderly men and men with risk factors or secondary causes for the condition. A bone mineral density (BMD) test is used for diagnosis. FRAX® can be used to predict the absolute ten-year fracture risk. Management includes reduction of risk factors or secondary causes, fall prevention, appropriate physical activity and a diet adequate in calcium and vitamin D. Referrals to specialists for evaluation and therapy can be considered, particularly for younger men with more severe disease. Current first-line drug treatment includes bisphosphonates and teriparatide. Testosterone increases BMD of the spine, but data on fracture risk reduction is unavailable. Public and physician education with the involvement of health authorities can create greater awareness of this silent condition, which can lead to complications, morbidity and death, if left untreated. PMID:25091882

  17. [Comparison of mid-term surgical results between plate and intramedullary nail for humeral shaft fracture].

    PubMed

    Zhao, G; Liu, H N; Li, N; He, L; Wu, X B

    2016-10-11

    Objective: To evaluate the mid-term clinical efficacy of plate and intramedullary nail for humeral shaft fracture. Methods: In this retrospective study a total of 122 patients with humeral shaft fracture were divided into 2 groups according to surgery type from May 2010 to July 2012. There were 63 patients in plate group and 59 patients in intramedullary nail group. The factors related to the operation for each group were compared respectively. The clinical outcome was evaluated by the Neer scores, Myao scores and EuroQol 5 dimensions scores (EQ-5D). All the patients were followed up periodically in the next 3 years. Results: There were no significant differences between the two groups on hospital stay and time of returning to work ( P >0.05). While the operation time, amount of intraoperative blood loss and complication rate were less in intramedullary nail group. The mean follow-up duration was (41.2±4.2) months in plate group and (42.1±4.7) months in intramedullary nail group respectively. At the last follow-up the postoperative Neer scores, Myao scores and EQ-5D scores showed no significant differences between the 2 groups[Neer: (93.8±6.1) vs(92.1±4.2); Myao: (94.9±2.9) vs(96.2±1.5), P >0.05]. There were no cases complicated with nonunion, delayed union, infection and deformity during the follow-up period. Conclusions: The mid-term outcome of open reduction and internal fixation with plate and close reduction with intramedullary nail for humeral shaft fracture is satisfactory. Although both surgeries are safe and effective, they also have some defaults. The doctors should choose the right surgery carefully according to the actual situation of the patients.

  18. Electromyography assessment in zygomaticomaxillary complex fractures.

    PubMed

    Waheed El-Anwar, Mohammad; Elsheikh, Ezzeddin; Sweed, Ahmed Hassan; Ezzeldin, Nillie

    2015-12-01

    The aim of this study was to assess the activity of the masseter and temporalis muscles using surface electromyography (EMG) in patients with zygomaticomaxillary complex (ZMC) fractures. This prospective study was carried out on 25 patients who had ZMC fractures. Fifteen patients were managed by open reduction and rigid fixation (ORIF) using titanium miniplates. This study, using surface electromyography, analyzed the activity of the masseter and temporalis muscles of 25 patients with ZMC fractures; 15 of them were surgically treated under general anesthesia (GA). Evaluations were made before surgery and 6 weeks after surgery by recording the mean of muscle contraction of 20 motor unit action potential (MUAP) against resistance, and statistical analyses were performed. A significant EMG difference between the normal and ZMC fracture sides was found (P < 0.0001) for both masseter and temporalis muscles and was significantly improved after ORIF. However, postoperative EMV values of the repaired side was significantly less than measured postoperatively in the normal side (P < 0.0001) for both muscles. ZMC fractures significantly diminish muscular activity of the masseter and temporalis and even though significant recovery of muscle activity was revealed after 6 weeks, it is still less than normal activity, highlighting the importance of postoperative rehabilitation.

  19. [Treatment of conmminuted patellar fractures with internal Ni-Ti patellar concentrator and tension bind wire fixation].

    PubMed

    Tan, Hong-lie; Qian, Chen; Zhao, Jin-kun; Shi, Yan; Zhou, Qi

    2009-02-01

    To study the clinical efficacy of the treatment of comminuted patellar fractures with internal NiTi-Patellar concentrator and tension bind wire fixation. From March 2004 to June 2007, 38 cases of fresh comminuted patellar fractures were treated with internal NiTi-Patellar concentrator and tension bind wire fixation. There were 25 males and 13 females,ranging from 21 to 64 years (mean 42.5 years). All were comminuted fractures with displacement, 16 cases were 3 fragments, 14 cases were 4 fragments, 8 cases were 5 fragments. There were other fractures in 8 cases. During followed-up, knee function and complications were evaluated. All patients were followed up for 8 to 24 months (mean 15 months) and obtained complete bone union. No case of implant was loosening and fragment displacement, traumatic arthritis occured in 2 cases. Under Lysholm & Gillquist score, the results were excellent in 17 cases, good in 19, fair in 2. Internal Ni-Ti-Patellar concentrator and tension bind wire fixation is one of the ideal methods for the treatment of comminuted patellar fracture, which could provide satisfied reduction, reliable fixation and good functional recovery.

  20. Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience

    PubMed Central

    Akbar, Saleem; Dhar, Shabir A.

    2008-01-01

    To assess the efficacy and feasibility of vertebroplasty and posterior short-segment pedicle screw fixation for the treatment of traumatic lumbar burst fractures. Short-segment pedicle screw instrumentation is a well described technique to reduce and stabilize thoracic and lumbar spine fractures. It is relatively a easy procedure but can only indirectly reduce a fractured vertebral body, and the means of augmenting the anterior column are limited. Hardware failure and a loss of reduction are recognized complications caused by insufficient anterior column support. Patients with traumatic lumbar burst fractures without neurologic deficits were included. After a short segment posterior reduction and fixation, bilateral transpedicular reduction of the endplate was performed using a balloon, and polymethyl methacrylate cement was injected. Pre-operative and post-operative central and anterior heights were assessed with radiographs and MRI. Sixteen patients underwent this procedure, and a substantial reduction of the endplates could be achieved with the technique. All patients recovered uneventfully, and the neurologic examination revealed no deficits. The post-operative radiographs and magnetic resonance images demonstrated a good fracture reduction and filling of the bone defect without unwarranted bone displacement. The central and anterior height of the vertebral body could be restored to 72 and 82% of the estimated intact height, respectively. Complications were cement leakage in three cases without clinical implications and one superficial wound infection. Posterior short-segment pedicle fixation in conjunction with balloon vertebroplasty seems to be a feasible option in the management of lumbar burst fractures, thereby addressing all the three columns through a single approach. Although cement leakage occurred but had no clinical consequences or neurological deficit. PMID:18193300

  1. Computational characterization of fracture healing under reduced gravity loading conditions.

    PubMed

    Gadomski, Benjamin C; Lerner, Zachary F; Browning, Raymond C; Easley, Jeremiah T; Palmer, Ross H; Puttlitz, Christian M

    2016-07-01

    The literature is deficient with regard to how the localized mechanical environment of skeletal tissue is altered during reduced gravitational loading and how these alterations affect fracture healing. Thus, a finite element model of the ovine hindlimb was created to characterize the local mechanical environment responsible for the inhibited fracture healing observed under experimental simulated hypogravity conditions. Following convergence and verification studies, hydrostatic pressure and strain within a diaphyseal fracture of the metatarsus were evaluated for models under both 1 and 0.25 g loading environments and compared to results of a related in vivo study. Results of the study suggest that reductions in hydrostatic pressure and strain of the healing fracture for animals exposed to reduced gravitational loading conditions contributed to an inhibited healing process, with animals exposed to the simulated hypogravity environment subsequently initiating an intramembranous bone formation process rather than the typical endochondral ossification healing process experienced by animals healing in a 1 g gravitational environment. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1206-1215, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures.

    PubMed

    Siebenrock, K A; Müller, U; Ganz, R

    1998-01-01

    Subtrochanteric fractures frequently occur as high energy trauma usually in younger patients and may lead to severe comminution of the medial cortex. The medial cortex of the proximal femur is exposed to high compressive forces which make fracture stabilization a difficult problem. Bone healing may be seriously compromised due to extensive comminution and fragment devitalization. This requires reduction techniques which do not cause additional damage to the vitality of the bone. With indirect reduction techniques and the use of a condylar blade plate the results have been significantly improved in these fracture types in our department (1). In this report the essential aspects of indirect reduction for subtrochanteric fractures using a condylar blade plate and the treatment results from our department from earlier years (1) and from the last 2 1/2 years will be presented. In the latter period, fifteen patients with a mean age of 49 years (19-87 years) were treated with this method. Fractures resulted from traffic incidents or falls from a great height in 11 cases (73%). Union was achieved in 14 cases (93%) with full weight-bearing after a mean of 3 months (1-4 1/2 months). Malunion was seen in two cases (13%) without the need for further surgery. Non union occurred in one patient (7%) with a III B open injury due to early infection. After repeated debridements, bone grafting and decortication, the fracture was stabilized with a replacement condylar blade plate and healed uneventfully.

  3. Does formal education and training of staff reduce the operation rate for fractures of the distal radius?

    PubMed

    McDonald, Kyle; Murphy, Lynn; Gallagher, Brendan; Eames, Niall

    2013-12-01

    Fractures of the distal radius are one of the most common extremity fractures, and operation rates are increasing. Staff within our unit felt that formal teaching, particularly of new medical staff, with regards to fracture reduction and appropriate cast application could result in a reduction in operation rates. Retrospective data was extracted from FORD (Fracture Outcome and Research Database), including: number of fractures, number of fractures undergoing ORIF, fracture configuration, patient demographics, and mechanism of injury. All patients undergoing ORIF had their radiographs assessed by two separate reviewers. Information regarding adequate fracture reduction, adequate cast application (using Gap Index), and appropriate plaster cast moulding was recorded. Formal teaching was then given to the next group of medical staff rotating through the unit, and the same data was collected prospectively for that six-month period. Exclusion criteria included bilateral injuries, and polytrauma patients. A total of 1623 distal radial fractures were treated in our unit over the 12-month period, with 71 undergoing ORIF in the first 6 months and 39 in the second 6 months, this was statistically significant (p = 0.0009). Our study found that formal teaching and education significantly reduced the operation rate for distal radial fractures. This effect was most significant for extra-articular, dorsally angulated fractures of the distal radius. Our study proves that just 1 h of basic training at the beginning of an attachment can have significant benefits to both the unit and, more importantly, the patients. Copyright © 2013 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  4. [Official position of the Chilean Society of Climacteric on the management of climacteric women].

    PubMed

    Blümel, Juan Enrique; Aravena, Hernán; Brantes, Sergio; Cruzat, Luis; Lavín, Pablo; Montaño, René; Navarrete, Isidoro; Osorio, Eduardo

    2010-05-01

    The health of many women is affected in the climacteric period, either by symptoms that deteriorate their life quality (QL) or by chronic diseases that affect their life expectancy. Therefore, it is mandatory to evaluate these two aspects, having as core objectives for any eventual therapeutic intervention, the improvement of QL and the reduction of cardiovascular risk and fractures. To evaluate QL it is mandatory to follow structured interviews that weigh systematically climacteric symptoms such as the Menopause Rating Scale (MRS). The paradigm of the metabolic syndrome constitutes a suitable frame to evaluate cardiovascular risk. Age, a low body weight, a history of fractures and steroid use are risk factors for fractures. A proper evaluation will allow the detection of patients with a low QL or a high risk for chronic disease, therefore identifying those women who require therapy. The clinical management should include recommendations to improve lifestyles, increase physical activity, avoidance of smoking and to follow a low calorie diet rich in vegetables and fruits. Hormonal therapy is the most efficient treatment to improve the QL and its risk is minimized when it is used in low doses or by the transdermal route. Tibolone is an alternative, especially useful in patients with mood disorders and sexual dysfunction. Vaginal estrogens are also a good option, when urogenital symptoms are the main complaint. Some antidepressants can be an effective therapy in patients with vasomotor symptoms who are not willing or cannot use estrogens. The effectiveness of any alternative therapy for menopausal symptoms has not been demonstrated. Dyslipidemia, hypertension, obesity and insulin resistance should be managed according to guidelines. Calcium and vitamin D have positive effects on bone density and certain tendency to reduce vertebral fractures. Bisphosphonates decrease the risk of vertebral fractures.

  5. Osteoporosis in men: a review.

    PubMed

    Adler, Robert A

    2014-01-01

    Osteoporosis and consequent fracture are not limited to postmenopausal women. There is increasing attention being paid to osteoporosis in older men. Men suffer osteoporotic fractures about 10 years later in life than women, but life expectancy is increasing faster in men than women. Thus, men are living long enough to fracture, and when they do the consequences are greater than in women, with men having about twice the 1-year fatality rate after hip fracture, compared to women. Men at high risk for fracture include those men who have already had a fragility fracture, men on oral glucocorticoids or those men being treated for prostate cancer with androgen deprivation therapy. Beyond these high risk men, there are many other risk factors and secondary causes of osteoporosis in men. Evaluation includes careful history and physical examination to reveal potential secondary causes, including many medications, a short list of laboratory tests, and bone mineral density testing by dual energy X-ray absorptiometry (DXA) of spine and hip. Recently, international organizations have advocated a single normative database for interpreting DXA testing in men and women. The consequences of this change need to be determined. There are several choices of therapy for osteoporosis in men, with most fracture reduction estimation based on studies in women.

  6. Osteoporosis in men: a review

    PubMed Central

    Adler, Robert A

    2014-01-01

    Osteoporosis and consequent fracture are not limited to postmenopausal women. There is increasing attention being paid to osteoporosis in older men. Men suffer osteoporotic fractures about 10 years later in life than women, but life expectancy is increasing faster in men than women. Thus, men are living long enough to fracture, and when they do the consequences are greater than in women, with men having about twice the 1-year fatality rate after hip fracture, compared to women. Men at high risk for fracture include those men who have already had a fragility fracture, men on oral glucocorticoids or those men being treated for prostate cancer with androgen deprivation therapy. Beyond these high risk men, there are many other risk factors and secondary causes of osteoporosis in men. Evaluation includes careful history and physical examination to reveal potential secondary causes, including many medications, a short list of laboratory tests, and bone mineral density testing by dual energy X-ray absorptiometry (DXA) of spine and hip. Recently, international organizations have advocated a single normative database for interpreting DXA testing in men and women. The consequences of this change need to be determined. There are several choices of therapy for osteoporosis in men, with most fracture reduction estimation based on studies in women. PMID:26273515

  7. The yerba mate intake has a neutral effect on bone: A case-control study in postmenopausal women.

    PubMed

    da Veiga, Denise T A; Bringhenti, Raísa; Bolignon, Aline A; Tatsh, Etiane; Moresco, Rafael N; Comim, Fabio V; Premaor, Melissa O

    2018-01-01

    Nutritional factors have been associated with osteoporosis and fractures. The intake of coffee may increase the risk of fracture whereas the intake of black and green tea is associated with its reduction. Recently, consumption of yerba mate was associated with increased bone mineral density in postmenopausal women. Nonetheless, its influence on fracture is not known. The aim of this study was to evaluate the effect of yerba mate tea intake on fractures, bone markers, calcium homeostasis, and oxidative stress in postmenopausal women. A case-control study was carried out in South Brazil, 46 women with fractures and 49 controls completed the study. There was no significant difference between the frequency of fractures in women who drank mate tea and women who did not (48.3% vs. 48.5%, p = .99). Moreover, there was no significant difference concerning the serum levels of total calcium, phosphorus, PTH, vitamin D, P1NP, and CTX in the subjects with the history of yerba mate use when compared to controls. Higher serum levels of NOx were found in women who drank the yerba mate infusion. In conclusion, the yerba mate intake is not associated with fracture, and it appears to have a neutral effect on the bone metabolism. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Superolateral dislocation of the intact mandibular condyle associated with panfacial fracture: a case report and literature review.

    PubMed

    Amaral, Márcio Bruno; Bueno, Sebastião Cristian; Silva, Alice Araújo Ferreira; Mesquita, Ricardo Alves

    2011-06-01

    Superolateral dislocation of the intact mandibular condyle (SDIMC) is rare. This case report focuses on a 15-year-old teenager who was involved in a motor vehicle accident as well a literature review regarding the SDIMC. Clinical examination demonstrated a diffuse edema in the midfacial area and a left lateral deflection of the mandible, including an open bite and a crepitation in the symphyseal region. Three-dimensional computed tomography scans were taken, which presented a superolateral dislocation of the left mandibular condyle as well as panfacial fracture. The patient was set in intermaxillary fixation for 2 weeks and underwent subsequent active jaw physiotherapy, the evaluation of which presented satisfactory results. This case study also presents a literature review, which demonstrated 21 well-documented cases of SDIMC. The patients' mean age was of 29 years. The male gender proved to be more prevalent, with road traffic collisions representing the most common form of accident. Type II, with unilateral dislocation, proved to be the most common. The mean reduction time was 7 days. The open methods were the most commonly used reduction methods. Mandible fracture was associated with dislocation in 82% of the cases, with other facial fractures appearing in only 23% of the cases. Patient follow up presented satisfactory results in 59% of the cases. © 2011 John Wiley & Sons A/S.

  9. Management of fractures of the mandibular body and symphysis.

    PubMed

    Goodday, Reginald H B

    2013-11-01

    Mandibular fracture, specifically in the symphysis and body regions combined, is the most common facial fracture requiring hospitalization in North America. The primary treatment objective is to restore form and function by achieving anatomic reduction and placing fixation that eliminates mobility of the bone fragments. Several treatment options and surgical techniques are available for performing closed or open reduction. Special considerations are necessary when treating pediatric patients and fractures of the edentulous mandible. Complications relating to the tooth and denture-bearing regions of the mandible include infection, nonunion, and neurosensory changes. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. The Effect of Sagittal Plane Deformities after Tibial Plateau Fractures to Functions and Instability of Knee Joint.

    PubMed

    Erdil, M; Yildiz, F; Kuyucu, E; Sayar, Ş; Polat, G; Ceylan, H H; Koçyiğit, F

    2016-01-01

    The objective of this study is to evaluate the effect of posterior tibial slope after fracture healing on antero-posterior knee laxity, functional outcome and patient satisfaction. 126 patients who were treated for tibial plateau fractures between 2008-2013 in the orthopedics and traumatology department of our institution were evaluated for the study. Patients were treated with open reduction and internal fixation, arthroscopy assisted minimally invasive osteosynthesis or conservative treatment. Mean posterior tibial slope after the treatment was 6.91 ± 5.11 and there was no significant difference when compared to the uninvolved side 6.42 ± 4,21 (p = 0.794). Knee laxity in anterior-posterior plane was 6.14 ± 2.11 and 5.95 ± 2.25 respectively on healthy and injured side. The difference of mean laxity in anterior-posterior plane between two sides was statistically significant. In this study we found no difference in laxity between the injured and healthy knees. However Tegner score decreased significantly in patients who had greater laxity difference between the knees. We did not find significant difference between fracture type and laxity, IKDC functional scores independent of the ligamentous injury. In conclusion despite coronal alignment is taken into consideration in treatment of tibial plateau fractures, sagittal alignment is reasonably important for stability and should not be ignored.

  11. Clinical characteristics and surgical experience of Type III Wagstaffe fractures: Pay attention to concomitant chondral injury of the talus.

    PubMed

    Zhang, Ming; Chen, Yun-Feng; Wang, Lei; Li, Fan; Wei, Hai-Feng; Shi, Zhong-Min

    2017-04-27

    The purpose of this study was to investigate clinical characteristics and surgical management of Type III Wagstaffe fracture. From August 2012 to July 2015, 13 patients with Type III Wagstaffe fractures were surgically treated. During operation, the cartilage of joint surface was explored. Wagstaffe fragment was fixed with cannulated screw or suture, Chaput fragment was fixed with cannulated screw or plate, and Cotton test was performed to evaluate the stability of syndesmosis during the operation. All the patients were followed up for 14.3 months in average. Clinical outcome was assessed with Olerud-Molander score and American Orthopedic Foot and Ankle Society (AOFAS) score. The traumatic arthritis was evaluated with osteoarthritis-score (OA-score). During the operation, chondral injury was found on the lateral top of the talus in 8 cases, as "kissing lesion" of Chaput fragment. The fractures healed uneventfully and all the patients recovered satisfactorily except two had moderate restriction in ankle movement. The average Olerud-Molander score and AOFAS score were 82.3 and 86.1, respectively. Type III Wagstaffe is a rare and often missed fracture. 61% are associated with a chondral lesion on the lateral top of the talus. Anatomical reduction and rigid fixation of both fragments are mandatory to obtain ankle stability and good results. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  12. [ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE IN ADOLESCENTS WITH EPIPHYSEAL UNCLOSURE].

    PubMed

    Liu, Yang; Sun, Xuebin; Zhang, Keyuan; Li, Gang; Ni, Jiati

    2015-06-01

    To evaluate the clinical results of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fractures in adolescents with epiphyseal unclosure. Between January 2011 and October 2013, 35 knees with ACL tibial eminence avulsion fractures (35 patients with epiphyseal unclosure) were arthroscopically treated with suture fixation. There were 25 males and 10 females, aged 8-16 years (mean, 14.7 years). The causes included sports injury in 24 cases, traffic accident injury in 9 cases, and daily life injury in 2 cases. According to Meyers-McKeever classification criteria, there were 27 cases of type II and 8 cases of type III. Five cases had meniscus injury. The preoperative the International Knee Documentation Committee (IKDC) score was 48.7 ± 3.2, and Lysholm score was 51.2 ± 4.5. The time from injury to operation was 2-16 days (mean, 5 days). Primary healing of incision was obtained in all patients. The mean follow-up time was 22.4 months (range, 12-32 months). Anatomical reduction was achieved in 28 cases and satisfactory reduction in 7 cases. X-ray films showed all fractures healing at last follow-up. There was no limb shortening deformity, varus knee, or valgus knee. Lachman test results were all negative. The other knees had normal range of motion except 1 knee with limited flexion, whose range of motion returned to 0-120° after treatment. At last follow-up, the IKDC score was significantly improved to 93.2 ± 4.1 (t = -53.442, P = 0.000), and the Lysholm score was significantly increased to 96.2 ± 2.5 (t = -56.242, P = 0.000). The arthroscopic fixation technique has satisfactory results for the reduction and fixation of ACL tibial eminence avulsion fracture in the adolescents with epiphyseal unclosure because of little trauma and quick recovery.

  13. [APPLICATION OF COMPUTER-ASSISTED SURGICAL PLANNING IN SURGICAL TREATMENT OF ANKLE FRACTURES].

    PubMed

    Xia, Shengli; Wang, Xiuhui; Fu, Beigang; Lu, Yaogang; Wang, Minghui

    2015-12-01

    To explore the clinical value of computer-assisted surgical planning in the treatment of ankle fractures. Between January 2012 and January 2014, open reduction and internal fixation were performed on 42 patients with ankle fractures. There were 22 males and 20 females with an average age of 52 years (range, 19-72 years). The causes were spraining injury (20 cases), traffic accident injury (14 cases), and falling from height injury (8 cases). The time from injury to operation was 5 hours to 12 days (mean, 2.5 days). All fractures were closed trimalleolar fractures. According to Lauge-Hansen classification, 25 cases were rated as supination extorsion type IV, 13 as pronation extorsion type IV, and 4 as pronation abduction type III. The preoperative planning was made by virtual reduction and internal fixation using Superimage software. The mean operation time was 93.7 minutes (range, 76-120 minutes). Delayed wound healing occurred in 1 case, and secondary healing was obtained after treatment; primary healing of incision was achieved in the other patients. Postoperative X-ray films and CT images showed anatomic reduction of fracture and good position of internal fixation. All patients were followed up 14.6 months on average (range, 9-27 months). The range of motion of the affected ankle was close to the normal side at 6-8 weeks. The mean fracture healing time was 13.1 weeks (range, 11-17 weeks). Degenerative change of the ankle joint was observed in 3 cases (7.1%) with manifestation of mild narrowing of joint space on the X-ray films at last follow-up. According to Baird-Jackson score system, the results were excellent in 24 cases, good in 13 cases, and fair in 5 cases, with an excellent and good rate of 88%. Computer-assisted surgical planning for ankle fractures can help surgeons identify type of ankle fractures and improve surgical scheme for guiding fracture reduction and selecting and placing implants, so good effectiveness can be obtained.

  14. Adjustable patella grapple versus cannulated screw and cable technique for treatment of transverse patellar fractures.

    PubMed

    Yan, Ning; Yang, Anli; Liu, Xiaodong; Cai, Feng; Liu, Liang; Chang, Shimin

    2014-03-01

    Although the cannulated screw and cable (CSC) tension band technique is an effective method for fixation of transverse patellar fractures, it has shortcomings, such as extensive soft tissue damage, osseous substance damage, and complex manipulation. We conducted a retrospective comparison of the adjustable patella grapple (APG) technique and the CSC tension band technique. We retrospectively reviewed 78 patients with transverse patellar fractures (45 in the APG group and 33 in the CSC group). Follow-up was 18 months. Comparison criteria were operation time, fracture reduction, fracture healing time, the knee injury and osteoarthritis outcome score for knee function, and complications. The APG group showed shorter operation time and equal fracture reduction, fracture healing time, and knee function compared with the CSC group. Eleven patients in the APG group experienced skin irritation generated by implants. There was no complication in the CSC group. The APG technique should be considered as an alternative method for treatment of transverse patellar fractures.

  15. Scaphocapitate Syndrome With Associated Trans-Scaphoid, Trans-Hamate Perilunate Dislocation

    PubMed Central

    Nunez, Fiesky A.; Luo, T. David; Jupiter, Jesse B.; Nunez, Fiesky A.

    2016-01-01

    Background: Perilunate fracture dislocations are often associated with fractures of the distal pole of the scaphoid or the proximal pole of the capitate. However, the combination of perilunate dislocation with multiple carpal fractures and associated scaphocapitate syndrome is very rare. Methods: We report a unique case of scaphocapitate fracture syndrome with perilunate dislocation and fracture of the hamate resulting from a high-energy injury to the wrist during a dirt-bike competition. Results: Open reduction and internal fixation of the scaphoid fracture with a 3.0-mm headless screw, the head of the capitate with a 1.5-mm lag screw, and the hamate fracture with a 1.3-mm lag screw was performed. The lunotriquetral dissociation was reduced, with the ligament repaired and the joint stabilized using a Kirschner wire. All screw heads are carefully buried under the articulate cartilage. Conclusions: Prompt anatomic reduction and stable osteosynthesis of all fractures in this patient resulted in successful healing and return to activity. PMID:28344539

  16. "A" shape plate for open rigid internal fixation of mandible condyle neck fracture.

    PubMed

    Kozakiewicz, Marcin; Swiniarski, Jacek

    2014-09-01

    Reduction of the fracture is crucial for proper outcome of the treatment. The stability of reduction is closed connected to the method of its fixation. The topic of condylar fracture osteosynthesis still remains highly controversial and challenging. That is why authors decided to propose novel design of the fixating plate and the example of its application. The aim of this study was to present A-shape plate dedicated to rigid fixation of mandible condyle neck fracture. A-shape condylar plate (ACP) design is prepared of 1.0 mm thick titanium alloy (grade 5) sheet: posterior and anterior bars are reinforced by widening to 2.5 mm and anatomically curved along the compression and traction lines in ramus and condylar neck. Superior three-hole-group has triangular organization and located on the level of condylar head. The inferior extensions of the bars are equipped in three holes located at each of lower tails. Connecting bar (2.0 mm wide) connects the first hole of each lower tails closing upper part of ACP in triangular shape. The connecting bar runs along compression line of condylar neck. Holes in ACP has 2.0 mm diameter for locking or normal screws. Height of ACP is 31 mm. The proposed new type of plate was compared by finite element analysis (FEA) to nowadays manufactured 9-hole trapezoid plate as the most similar device. ACP design was evaluated by finite element analysis (FEA) and later applied in patient affected with high condylar neck fracture complicated by fracture of coronoid process. FEA revealed high strength of ACP and more stabile fixation than trapezoid plate. The result was caused by multipoint fixation at three regions of the plate and reinforced bars supported by semi-horizontal connecting bar. Clinical application of ACP was as versatile as makes possible to simultaneous fixation of high condylar neck and coronoid process fracture. Application of proposed A-shape condylar plate would be possible in all levels of neck fractures and can be use for stabilization additionally existed coronoid process fracture. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome.

    PubMed

    Pan, M; Chai, L; Xue, F; Ding, L; Tang, G; Lv, B

    2017-07-01

    The aim of this study was to compare the biomechanical stability and clinical outcome of external fixator combined with limited internal fixation (EFLIF) and open reduction and internal fixation (ORIF) in treating Sanders type 2 calcaneal fractures. Two types of fixation systems were selected for finite element analysis and a dual cohort study. Two fixation systems were simulated to fix the fracture in a finite element model. The relative displacement and stress distribution were analysed and compared. A total of 71 consecutive patients with closed Sanders type 2 calcaneal fractures were enrolled and divided into two groups according to the treatment to which they chose: the EFLIF group and the ORIF group. The radiological and clinical outcomes were evaluated and compared. The relative displacement of the EFLIF was less than that of the plate (0.1363 mm to 0.1808 mm). The highest von Mises stress value on the plate was 33% higher than that on the EFLIF. A normal restoration of the Böhler angle was achieved in both groups. No significant difference was found in the clinical outcome on the American Orthopedic Foot and Ankle Society Ankle Hindfoot Scale, or on the Visual Analogue Scale between the two groups (p > 0.05). Wound complications were more common in those who were treated with ORIF (p = 0.028). Both EFLIF and ORIF systems were tested to 160 N without failure, showing the new construct to be mechanically safe to use. Both EFLIF and ORIF could be effective in treating Sanders type 2 calcaneal fractures. The EFLIF may be superior to ORIF in achieving biomechanical stability and less blood loss, shorter surgical time and hospital stay, and fewer wound complications. Cite this article : M. Pan, L. Chai, F. Xue, L. Ding, G. Tang, B. Lv. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome. Bone Joint Res 2017;6:433-438. DOI: 10.1302/2046-3758.67.2000640. © 2017 Xue et al.

  18. Treatment of displaced mandibular condylar fracture with botulinum toxin A.

    PubMed

    Akbay, Ercan; Cevik, Cengiz; Damlar, Ibrahim; Altan, Ahmet

    2014-04-01

    The aim of this case report is to discuss the effect on condylar reduction of botulinum toxin A treatment used in a child with displaced fracture at condylar neck of mandible. A 3-years old boy was admitted to our clinic for incomplete fracture of mandibular symphysis and displaced condylar fracture at the left side. An asymmetrical occlusal splint with intermaxillary fixation was used instead of open reduction and internal fixation because of incomplete fracture of symphysis and possible complications of condyle surgery. However, it was observed that condylar angulation persisted despite this procedure. Thus, botulinum toxin A was administered to masseter, temporalis and pterygoideus medialis muscles. At the end of first month, it was seen that mandibular condyle was almost completely recovered and that fusion was achieved. In conclusion, Botulinum A toxin injection aiming the suppression of masticatory muscle strength facilitates the reduction in the conservative management of displaced condyle in pediatric patients. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Balloon osteoplasty--a new technique for reduction and stabilisation of impression fractures in the tibial plateau: a cadaver study and first clinical application.

    PubMed

    Ahrens, Philipp; Sandmann, Gunther; Bauer, Jan; König, Benjamin; Martetschläger, Frank; Müller, Dirk; Siebenlist, Sebastian; Kirchhoff, Chlodwig; Neumaier, Markus; Biberthaler, Peter; Stöckle, Ulrich; Freude, Thomas

    2012-09-01

    Fractures of the tibial plateau are among the most severe injuries of the knee joint and lead to advanced gonarthrosis if the reduction does not restore perfect joint congruency. Many different reduction techniques focusing on open surgical procedures have been described in the past. In this context we would like to introduce a novel technique which was first tested in a cadaver setup and has undergone its successful first clinical application. Since kyphoplasty demonstrated effective ways of anatomical correction in spine fractures, we adapted the inflatable instruments and used the balloon technique to reduce depressed fragments of the tibial plateau. The technique enabled us to restore a congruent cartilage surface and bone reduction. In this technique we see a useful new method to reduce depressed fractures of the tibial plateau with the advantages of low collateral damage as it is known from minimally invasive procedures.

  20. Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hampton, Jesse; Gutierrez, Marte; Matzar, Luis

    Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less

  1. Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests

    DOE PAGES

    Hampton, Jesse; Gutierrez, Marte; Matzar, Luis; ...

    2018-06-11

    Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less

  2. Bone mineral density at different sites and vertebral fractures in Serbian postmenopausal women.

    PubMed

    Ilic Stojanovic, O; Vuceljic, M; Lazovic, M; Gajic, M; Radosavljevic, N; Nikolic, D; Andjic, M; Spiroski, D; Vujovic, S

    2017-02-01

    This randomized study aimed to evaluate the correlation between bone mineral densities (BMD) measured at different sites and the frequency of vertebral fractures in a group of Serbian postmenopausal women. BMD was measured in 130 naïve postmenopausal women by dual X-ray absorptiometry (DXA) at the ultra-distal part of the forearms, at the hip and at the lumbar spine. At each of the measurement sites, the patients were categorized as osteoporotic, or osteopenic, or in the reference range. Vertebral fractures were examined using thoracic and lumbar spine radiography. A T-score at different skeletal sites showed discordance in the site-specific region. Vertebral fractures were found in 58.82% of patients with hip osteopenia, in 45% with forearm osteopenia and in 54.54% with lumbar spine osteoporosis. The study confirmed that the reduction of BMD depends on age and choice of measurement site. The best correlation was obtained in the women with osteopenia at all measurement sites. The discovery of vertebral fractures by lateral thoracic and lumbar spine radiography improves prompt treatment. Reference values of BMD do not exclude vertebral fractures. Of vertebral fractures, 72.5% were asymptomatic and thus spine radiographies are obligatory. Currently discussed is the position of DXA for measuring BMD as a method of detection for patients at risk of fracture.

  3. Clavicle Shaft Fractures in Adolescents.

    PubMed

    Yang, Scott; Andras, Lindsay

    2017-01-01

    Midshaft clavicle fractures in adolescents are common. Recent literature in adults fractures favors open reduction and plate fixation for significantly displaced and/or shortened midshaft clavicle fractures, although whether this applies to adolescents remains debatable. This article reviews the current literature and controversy in the management of displaced adolescent clavicle fractures. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. [Treatment of complex tibial plateau fractures with bilateral locking plate and bone graft].

    PubMed

    Yan, Ying-Jie; Cheng, Zhan-Wei; Feng, Kai; Yan, Shao-Hua

    2012-07-01

    To explore the effective methods for the treatment of complex tibial plateau fractures. From May 2008 to April 2011, 28 patients with complex tibial plateau fractures were treated indirect reduction techniques, bilateral locking plate fixation combined with autologous bone grafts. There were 21 males and 7 females, with an average age of 43 years ranging from 21 to 65. There were 11 cases in Schatzker type V, 17 in VI. The effect was evaluated by Rasmussen standard on clinical and radiological. All patients were followed-up for 7 to 36 months (averaged of 21.5 months). Healing time of fracture was from 3 to 8 months (averaged 5.5 months). The results of Rasmussen scores in clinical was 4.50 +/- 1.32 in pain, 4.32 +/- 1.63 in walking ability, 4.07 +/- 1.34 in knee activity, 4.78 +/- 1.27 in stability of the knee, 4.85 +/- 1.12 in stretch knee; the results in radiation was 5.07 +/- 0.92 in articular surface collapse, 5.00 +/- 0.98 in platform widened, 5.14 +/- 0.85 in knee external varus. The effect result was excellent in 8 cases, good in 15, fair in 3 and poor in 2. The key for the treatment of complex tibial plateau fractures was to fully assess the damage as much as possible to protect the soft tissue, select the appropriate timing of surgery and surgical incision, application of indirect reduction techniques, limited incision and effective internal fixation to restore joint surface smooth and good limb alignment, early exercise, in order to achieve maximum recovery of joint function.

  5. Combined Volar and Dorsal Approach for Fixation of Comminuted Intra-Articular Distal Radial Fractures.

    PubMed

    Medlock, G; Smith, M; Johnstone, A J

    2018-07-01

    Purpose  Multifragmentary intra-articular fractures displaced in multiple planes are a challenge. We use a reproducible technique of fracture and articular reduction using an initial volar approach targeting reduction in the volar lunate facet first with plate and unicortical locking screws. This creates a template for reduction in dorsal fragments through a dorsal approach. Our study investigated the radiological, clinical, and functional outcomes of patients treated with this technique. Materials and Methods  We reviewed the postoperative radiographs and notes of 18 patients that had this method of fixation between the years 2008 and 2015, the mean age being 43. These patients were reviewed functionally on average 2 years and 3 months following their definitive operation. Results  Normal alignment and length to the distal radius were restored with on average a 0.6 mm articular step. The average range of motion was 64% and preservation of grip strength was 71% compared with the uninjured wrist. Functional assessment averages were 29 for both the quick Disabilities of the Arm, Shoulder and Hand (DASH) and for Patient Rated Wrist Evaluation. The modified system of Green and O'Brien had results of good in 10, fair in 7, and poor in 1. With respect to the Gartland and Werley system, three patients had an excellent result, four had a good result, six had a fair result, and five had a poor result. The mean arthritic grading was 1 (grading 0-3) according to Knirk and Jupiter. Conclusion  This reproducible technique provides an option for these devastating fractures providing a functioning wrist with all of the patients returning to their original form of employment.

  6. External fixation techniques for distal radius fractures.

    PubMed

    Capo, John T; Swan, Kenneth G; Tan, Virak

    2006-04-01

    Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. Level V (expert opinion).

  7. Locked compression plating for peri- and intra-articular fractures around the knee.

    PubMed

    Jain, Jitesh Kumar; Asif, Naiyer; Ahmad, Suhail; Qureshi, Owais; Siddiqui, Yasir Salam; Rana, Ashish

    2013-11-01

    To evaluate the role of locked compression plates (LCPs) in management of peri- and intra-articular fractures around the knee. Twenty distal femoral and 20 proximal tibial fractures were fixed with LCPs. The types of femoral fractures were A1 (four), A2 (three), A3 (two), C1 (one), C2 (seven) and C3 (three). The types of tibial fractures were A2 (one), A3 (two), B2 (two), C1 (four), C2 (five) and C3 (six). All patients were followed up for up to 18 months (mean, 12 months). Fourteen patients with distal femoral fractures and 19 with proximal tibial fractures underwent surgery using a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. The others were treated by open reduction. The average time of fixation was 8 days after injury (0-31 days). Knee Society scores were used for clinical and functional assessment. All fractures, except one of the distal femur and one of the proximal tibia, united. The mean union times for distal femoral and proximal tibial fractures were 15.2 and 14.9 weeks, respectively. One patient with a distal femoral fracture had implant failure. One patient was quadriplegic and did not recover the ability to walk. The average Knee Society scores of the remaining 18 patients were 82.66 (excellent) and 77.77 (functional score, good). There was one case of implant failure and one of screw breakage in distal femoral fractures. One case of nonunion occurred in a proximal tibial fracture. Provided it is applied with proper understanding of biomechanics, LCP is one of the best available options for management of challenging peri- and intra-articular fractures. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  8. A Novel Approach for Treatment of Acetabular Fractures

    PubMed Central

    Xue, Zichao; Qin, Hui; Ding, Haoliang; An, Zhiquan

    2016-01-01

    Background There is no single approach that provides adequate exposure for treatment of all types of acetabular fractures. We describe our experience with an easier, relatively less invasive pubic symphysis approach (PSA) for the treatment of acetabular fractures. Material/Methods Between March 2011 and March 2012, fifteen patients with acetabular fracture underwent surgery using the PSA technique. Fracture reduction and treatment outcomes were assessed by clinical and radiological examination. Operation time, intraoperative blood loss and postoperative complications were documented. Results Mean operative time was 222±78 minutes. Average blood loss was 993±361 mL. Anatomical reduction was achieved in all patients. Minimum follow-up period was 31 months. Postoperative hypoesthesia in the area of innervation of the lateral femoral cutaneous nerve was reported in one patient, with spontaneous recovery at one month after surgery. No complications were reported during the follow-up period. At the most recent follow up, clinical outcomes were graded as “excellent” in six patients, “good” in eight patients and “fair” in one patient based on the modified Merle d’Aubigné-Postel score. Conclusions PSA appears to be a timesaving and safe approach for treatment of acetabular fractures that affords good visual access and allows for excellent fracture reduction. Our preliminary results revealed a much lower incidence of complications than traditional approaches, suggesting PSA is an alternative for treatment of acetabular fractures. PMID:27734825

  9. Impact of microbial activity on the hydraulic properties of fractured chalk.

    PubMed

    Arnon, Shai; Adar, Eilon; Ronen, Zeev; Yakirevich, Alexander; Nativ, Ronit

    2005-02-01

    The impact of microbial activity on fractured chalk transmissivity was investigated on a laboratory scale. Long-term experiments were conducted on six fractured chalk cores (20 cm diameter, 23-44 cm long) containing a single natural fracture embedded in a porous matrix. Biodegradation experiments were conducted under various conditions, including several substrate and oxygen concentrations and flow rates. 2,4,6-Tribromophenol (TBP) was used as a model contaminant (substrate). TBP biodegradation efficiency depended mainly on the amount of oxygen. However, under constant oxygen concentration at the core inlet, elevating the flow rates increased the removal rate of TBP. Transmissivity reduction was clearly related to TBP removal rate, following an initial slow decline and a further sharp decrease with time. The fracture's transmissivity was reduced by as much as 97% relative to the initial value, with no leveling off of the clogging process. For the most extreme cases, reductions of 262 and 157 microm in the equivalent hydraulic apertures were recorded for fractures with initial apertures of 495 and 207 microm, respectively. The reductions in fracture transmissivity occurred primarily because of clogging by bacterial cells and extracellular polymeric substances (EPS) produced by the bacteria. Most of the biodegradation activity was concentrated near the fracture inlet, where the most suitable biodegradation conditions (nutrients and oxygen) prevailed, suggesting that the clogging had occurred in that vicinity. The clogging must have changed the structure of the fracture void, thereby reducing the active volume participating in flow and transport processes. This phenomenon caused accelerated transport of non-reactive tracers and doubled the fracture's dispersivity under constant flow rates.

  10. [Treatment of calcaneal fractures with a locking nail (C-Nail)].

    PubMed

    Pompach, M; Carda, M; Amlang, M; Zwipp, H

    2016-06-01

    Anatomic reconstruction of the posterior facet by primary stabilization of the calcaneal fracture with a locking nail. All intraarticular calcaneal fractures and unstable two-part fractures independent of the degree of closed/open soft tissue trauma. High perioperative risk, soft tissue infection, beak fracture (type II fracture) and still open apophysis. Anatomic reduction of the posterior facet using a sinus tarsi approach. Reduction and temporary fixation of the sustentacular, tuberosity, and anterior process fragments with 1.8-2.0 mm Kirschner wires. Thereafter, the C-Nail (calcaneus nail) is introduced with its guiding device stabilizing the sustentacular, tuberostity, and anterior process fragments through its three guiding arms with 6 or 7 locking screws. Passive and active motion starts on postoperative day 2. Lymph drains help reduce swelling. Partial weightbearing with 20 kg for 6-8 weeks in the patient's own shoes is recommended. X‑ray controls are done at 4 and 8 weeks as well as after 6 and 12 months. A total of 107 calcaneal fractures treated with the C-Nail between 2011 and 2014 were evaluated according to the AOFAS score 6 months and 1 year after surgery. The measured values were on average 93.0 (range 65-100) points at 6 months and 94.1 (range 75-100) points 12 months after the surgery. Böhler's angle with initial traumatic values of 6.2° (-30 to +13°) improved postoperatively to 31.8°, after 3 months slightly decreased to 29.6°, and after 12 months to 28.3°. There were 2 cases of superficial wound necrosis (1.9 %) and 1 case a deep infection (0.93 %) with need of early C-Nail removal.

  11. Three lateral divergent or parallel pin fixations for the treatment of displaced supracondylar humerus fractures in children.

    PubMed

    Lee, Young Ho; Lee, Sang Ki; Kim, Byung Sung; Chung, Moon Sang; Baek, Goo Hyun; Gong, Hyun Sik; Lee, Joon Kyu

    2008-06-01

    To evaluate the efficacy of lateral or parallel pin fixation using 3 smooth Kirschner wires (K-wires) or smooth Steinmann pins for the operative management of displaced supracondylar humeral fracture in a consecutive series of children. Sixty-one consecutive displaced or angled supracondylar humeral fractures (Gartland type II or III) in children (mean age, 5 years 6 months) treated by 2 orthopaedic surgeons between 2001 and 2004 according to the following protocol: close reduction under general anesthesia with fluoroscopic guidance and only lateral percutaneous pinning using 3 divergent or parallel Kirschner wires or Steinmann pins. Minimum 2 years' follow-up was done in all 61 patients (range, 2.0-3.3 years). Clinical assessment was obtained at final follow-up using Flynn criteria, and radiologic assessment was obtained using the Baumann and lateral humerocapitellar angles of both arms. Statistical analysis was performed by means of the Student t test (P < 0.05). The study group consisted of 61 patients, of whom 24 (39%) presented with Gartland type II fractures, and the remaining 37 (61%) presented with a type III fracture. A comparison of perioperative and final radiographs shows no loss of reduction of any fracture. There was also no clinically evident cubitus varus, hyperextension, or loss of motion. Eight patients had preoperative nerve palsy. Five of these nerve injuries resolved immediately after surgery, and the other 3 resolved completely within 12 weeks of surgery. After an average of 28 months postoperation, 56 (91.8%) patients had achieved an excellent clinical result, and 5 (8.2%) achieved a good result. There were no iatrogenic nerve palsies, and no patient required additional surgery. One patient had a minor pin-track infection. Our series demonstrates that only 3 lateral divergent or parallel pin fixations are effective and safe for avoiding iatrogenic ulnar nerve injury and are appropriate treatment options for displaced or angled supracondylar humeral fractures in children. Therapeutic study, level III.

  12. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    PubMed

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  13. Quantifying voids effecting delamination in carbon/epoxy composites: static and fatigue fracture behavior

    NASA Astrophysics Data System (ADS)

    Hakim, I.; May, D.; Abo Ras, M.; Meyendorf, N.; Donaldson, S.

    2016-04-01

    On the present work, samples of carbon fiber/epoxy composites with different void levels were fabricated using hand layup vacuum bagging process by varying the pressure. Thermal nondestructive methods: thermal conductivity measurement, pulse thermography, pulse phase thermography and lock-in-thermography, and mechanical testing: modes I and II interlaminar fracture toughness were conducted. Comparing the parameters resulted from the thermal nondestructive testing revealed that voids lead to reductions in thermal properties in all directions of composites. The results of mode I and mode II interlaminar fracture toughness showed that voids lead to reductions in interlaminar fracture toughness. The parameters resulted from thermal nondestructive testing were correlated to the results of mode I and mode II interlaminar fracture toughness and voids were quantified.

  14. Pediatric mandibular fractures treated by rigid internal fixation.

    PubMed

    Wong, G B

    1993-09-01

    Mandibular fractures in the pediatric patient population are relatively uncommon. These patients present with their own unique treatment requirements. Most fractures have been treated conservatively by dental splints. Closed reduction techniques with maxillomandibular fixation (MMF) in very young children can pose several concerns, including cooperation, compliance and adequate nutritional intake. Rigid internal fixation of unstable mandibular fractures using miniplates and screws circumvents the need for MMF and allows immediate jaw mobilization. At major pediatric trauma institutions, there has been an increasing trend toward the use of this treatment when open reduction is necessary. This article presents a report of a five-year-old child who presented with bilateral mandibular fractures and was treated by rigid internal fixation and immediate mandibular mobilization.

  15. Gradual Reduction of Chronic Fracture Dislocation of the Ankle Using Ilizarov/Taylor Spatial Frame

    PubMed Central

    Deland, Jonathan T.; Rozbruch, S. Robert

    2010-01-01

    With the advances in trauma care, chronic fracture dislocation of the ankle is not a condition commonly seen in modern clinical practice. When encountered, it can be difficult to preserve the ankle joint. We present a case of a 65-year-old female, with a chronic fracture dislocation of the ankle. The ankle joint was subluxated with posterior translation of the talus, displacement of the posterior malleolus fragment, and a distal fibula fracture. A minimally traumatic approach was devised to treat this complex fracture dislocation which included gradual reduction of the ankle with a Taylor spatial frame, followed by stabilization with internal fixation and removal of the frame. Bony union and restoration of the ankle joint congruency was achieved. PMID:22294963

  16. Acute knee injuries: use of decision rules for selective radiograph ordering.

    PubMed

    Tandeter, H B; Shvartzman, P; Stevens, Max A

    1999-12-01

    Family physicians often encounter patients with acute knee trauma. Radiographs of injured knees are commonly ordered, even though fractures are found in only 6 percent of such patients and emergency department physicians can usually discriminate clinically between fracture and nonfracture. Decision rules have been developed to reduce the unnecessary use of radiologic studies in patients with acute knee injury. The Ottawa knee rules and the Pittsburgh decision rules are the latest guidelines for the selective use of radiographs in knee trauma. Application of these rules may lead to a more efficient evaluation of knee injuries and a reduction in health costs without an increase in adverse outcomes.

  17. Strontium ranelate reduces the risk of vertebral fractures in patients with osteopenia.

    PubMed

    Seeman, Ego; Devogelaer, Jean-Pierre; Lorenc, Roman; Spector, Timothy; Brixen, Kim; Balogh, Adam; Stucki, Gerold; Reginster, Jean-Yves

    2008-03-01

    Many fractures occur in women with moderate fracture risk caused by osteopenia. Strontium ranelate was studied in 1431 postmenopausal women with osteopenia. Vertebral fracture risk reduction of 41-59% was shown depending on the site and fracture status at baseline. This is the first report of antivertebral fracture efficacy in women with vertebral osteopenia. Women with osteoporosis are at high risk for fracture. However, more than one half of all fractures in the community originate from the larger population at more moderate risk of fracture caused by osteopenia. Despite this, evidence for antifracture efficacy in these persons is limited. The aim of this study was to determine whether strontium ranelate, a new drug that reduces fracture risk in women with osteoporosis, is also effective in women with osteopenia. Data from the Spinal Osteoporosis Therapeutic Intervention study (SOTI; n = 1649) and the TReatment Of Peripheral OSteoporosis (TROPOS; n = 5091) were pooled to evaluate the antivertebral fracture efficacy of strontium ranelate in women with lumbar spine (LS) osteopenia with any BMD value at the femoral neck (FN; N = 1166) and in 265 women with osteopenia at both sites (intention-to-treat analysis). The women were randomized to strontium ranelate 2 g/d orally or placebo for 3 yr. No group differences were present in baseline characteristics that may influence fracture outcome independent of therapy. In women with LS osteopenia, treatment reduced the risk of vertebral fracture by 41% (RR = 0.59; 95% CI, 0.43-0.82), by 59% (RR = 0.41; 95% CI, 0.17-0.99) in the 447 patients with no prevalent fractures, and by 38% (RR = 0.62; 95% CI, 0.44-0.88) in the 719 patients with prevalent fractures. In women with osteopenia at both sites, treatment reduced the risk of fracture by 52% (RR = 0.48; 95% CI, 0.24-0.96). Strontium ranelate safely reduces the risk of vertebral fractures in women with osteopenia with or without a prevalent fracture.

  18. Survival of resin infiltrated ceramics under influence of fatigue.

    PubMed

    Aboushelib, Moustafa N; Elsafi, Mohamed H

    2016-04-01

    to evaluate influence of cyclic fatigue on two resin infiltrated ceramics and three all-ceramic crowns manufactured using CAD/CAM technology. CAD/CAM anatomically shaped crowns were manufactured using two resin infiltrated ceramics (Lava Ultimate and Vita Enamic), two reinforced glass ceramic milling blocks ((IPS)Empress CAD and (IPS)e.max CAD) and a veneered zirconia core ((IPS)Zir CAD). (IPS)e.max CAD and (IPS)Zir CAD were milled into 0.5mm thick anatomically shaped core structure which received standardized press-on veneer ceramic. The manufactured crowns were cemented on standardized resin dies using a resin adhesive (Panavia F2.0). Initial fracture strength of half of the specimens was calculated using one cycle load to failure in a universal testing machine. The remaining crowns were subjected to 3.7 million chewing cycles (load range 50-200N at 3s interval) in a custom made pneumatic fatigue tester. Survival statistics were calculated and Weibull modulus was measured from fitted load-cycle-failure diagrams. Scanning electron microscopy was performed to fractographically analyze fractured surfaces. Data were analyzed using two way analysis of variance and Bonferroni post hoc tests (α=0.05). Dynamic fatigue resulted in significant reduction (F=7.54, P<0.005) of the initial fracture strength of the tested specimens. Zirconia showed the highest deterioration percent (34% reduction in strength) followed by (IPS)Empress (32.2%), (IPS)e.max (27.1%) while Lava Ultimate and Vita Enamic showed the lowest percent of reduction in strength. The two types of resin infiltrated ceramics and (IPS)Empress demonstrated the highest percent of fracture incidences under the influence of fatigue (35-45% splitting). None of the tested veneered zirconia restorations were fractured during testing, however, chipping of the veneer ceramics was observed in 6 crowns. The lowest percent of failure was observed for (IPS)e.max crowns manifested as 3 cases of minor chipping in addition to two complete fracture incidences. SEM images demonstrated the internal structure of the tested materials and detected location and size of the critical crack. The internal structure of the tested materials significantly influenced their fatigue behavior. Resin infiltrated ceramics were least influenced by fatigue while the characteristic strength of zirconia prevented core fracture but failure still occurred from the weaker veneer ceramic. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Open reduction and internal fixation of intra-articular fractures of the mandibular condyle: our first experiences.

    PubMed

    Vesnaver, Ales

    2008-10-01

    Treatment of intra-articular fractures of the mandibular condyle head is conservative at most institutions dealing with facial fractures. Recently, reports had been published about benefits of surgical treatment in these fractures. From July 2004 until the end of June 2006, 13 patients with 16 displaced intra-articular fractures of the mandibular condyle were treated with open reduction and internal fixation at the Department of Oral and Maxillofacial Surgery in Ljubljana, Slovenia, using the preauricular approach and the lag screw technique. Twelve of the 13 patients could open their mouths for 40 mm or more, and 10 had a deflection of the chin of less than 2 mm upon maximal opening. None of the patients experienced pain upon rest, palpation, or chewing. Occlusion was not noted as altered in any of the cases, neither subjectively, nor on examination. There were no cases of postoperative weakness of the temporal branch of the facial nerve. Surgical treatment of intra-articular condyle fractures using the preauricular approach achieves a good exposure and enables proper reduction. Stable fixation of fractured bony fragments can be achieved using the lag screw technique. Another benefit of open exposure is revision and repair of TMJ soft tissues. With the appropriate surgical technique, the surgical procedure is safe and leads to good results.

  20. Management of proximal humeral fractures in the nineteenth century: an historical review of preradiographic sources.

    PubMed

    Brorson, Stig

    2011-04-01

    The diagnosis and treatment of fractures of the proximal humerus have troubled patients and medical practitioners since antiquity. Preradiographic diagnosis relied on surface anatomy, pain localization, crepitus, and impaired function. During the nineteenth century, a more thorough understanding of the pathoanatomy and pathophysiology of proximal humeral fractures was obtained, and new methods of reduction and bandaging were developed. I reviewed nineteenth-century principles of (1) diagnosis, (2) classification, (3) reduction, (4) bandaging, and (5) concepts of displacement in fractures of the proximal humerus. A narrative review of nineteenth-century surgical texts is presented. Sources were identified by searching bibliographic databases, orthopaedic sourcebooks, textbooks in medical history, and a subsequent hand search. Substantial progress in understanding fractures of the proximal humerus is found in nineteenth-century textbooks. A rational approach to understanding fractures of the proximal humerus was made possible by an appreciation of the underlying functional anatomy and subsequent pathoanatomy. Thus, new principles of diagnosis, pathoanatomic classifications, modified methods of reduction, functional bandaging, and advanced concepts of displacement were proposed, challenging the classic management adhered to for more than 2000 years. The principles for modern pathoanatomic and pathophysiologic understanding of proximal humeral fractures and the principles for classification, nonsurgical treatment, and bandaging were established in the preradiographic era.

  1. Zoledronic Acid in Reducing Clinical Fracture and Mortality after Hip Fracture

    PubMed Central

    Lyles, Kenneth W.; Colón-Emeric, Cathleen S.; Magaziner, Jay S.; Adachi, Jonathan D.; Pieper, Carl F.; Mautalen, Carlos; Hyldstrup, Lars; Recknor, Chris; Nordsletten, Lars; Moore, Kathy A.; Lavecchia, Catherine; Zhang, Jie; Mesenbrink, Peter; Hodgson, Patricia K.; Abrams, Ken; Orloff, John J.; Horowitz, Zebulun; Eriksen, Erik Fink; Boonen, Steven

    2008-01-01

    BACKGROUND Mortality is increased after a hip fracture, and strategies that improve outcomes are needed. METHODS In this randomized, double-blind, placebo-controlled trial, 1065 patients were assigned to receive yearly intravenous zoledronic acid (at a dose of 5 mg), and 1062 patients were assigned to receive placebo. The infusions were first administered within 90 days after surgical repair of a hip fracture. All patients received supplemental vitamin D and calcium. The median follow-up was 1.9 years. The primary end point was a new clinical fracture. RESULTS The rates of any new clinical fracture were 8.6% in the zoledronic acid group and 13.9% in the placebo group, a 35% risk reduction (P = 0.001); the respective rates of a new clinical vertebral fracture were 1.7% and 3.8% (P = 0.02), and the respective rates of new nonvertebral fractures were 7.6% and 10.7% (P = 0.03). In the safety analysis, 101 of 1054 patients in the zoledronic acid group (9.6%) and 141 of 1057 patients in the placebo group (13.3%) died, a reduction of 28% in deaths from any cause in the zoledronic-acid group (P = 0.01). The most frequent adverse events in patients receiving zoledronic acid were pyrexia, myalgia, and bone and musculoskeletal pain. No cases of osteonecrosis of the jaw were reported, and no adverse effects on the healing of fractures were noted. The rates of renal and cardiovascular adverse events, including atrial fibrillation and stroke, were similar in the two groups. CONCLUSIONS An annual infusion of zoledronic acid within 90 days after repair of a low-trauma hip fracture was associated with a reduction in the rate of new clinical fractures and improved survival. (ClinicalTrials.gov number, NCT00046254.) PMID:17878149

  2. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation

    PubMed Central

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-01-01

    Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890

  3. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    PubMed

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  4. Influence of rotational speed on the cyclic fatigue of rotary nickel-titanium endodontic instruments.

    PubMed

    Lopes, Hélio P; Ferreira, Alessandra A P; Elias, Carlos N; Moreira, Edson J L; de Oliveira, Júlio C Machado; Siqueira, José F

    2009-07-01

    During the preparation of curved canals, rotary nickel-titanium (NiTi) instruments are subjected to cyclic fatigue, which can lead to instrument fracture. Although several factors may influence the cyclic fatigue resistance of instruments, the role of the rotational speed remains uncertain. This study was intended to evaluate the effects of rotational speed on the number of cycles to fracture of rotary NiTi instruments. ProTaper Universal instruments F3 and F4 (Maillefer SA, Ballaigues, Switzerland) were used in an artificial curved canal under rotational speeds of 300 rpm or 600 rpm. The artificial canal was made of stainless steel, with an inner diameter of 1.5 mm, total length of 20 mm, and arc at the end with a curvature radius of 6 mm. The arc length was 9.4 mm and 10.6 mm on the straight part. The number of cycles required to fracture was recorded. Fractured surfaces and the helical shafts of the fractured instruments were analyzed by scanning electron microscopy. The results showed approximately a 30% reduction in the observed number of cycles to fracture as rotational speed was increased from 300 to 600 RPM (p < 0.05). The morphology of the fractured surface was always of ductile type, and no plastic deformation was observed on the helical shaft of fractured instruments. The present findings for both F3 and F4 ProTaper instruments revealed that the increase in rotational speed significantly reduced the number of cycles to fracture.

  5. Activities of Daily Living and Determinant Factors among Older Adult Subjects with Lower Body Fracture after Discharge from Hospital: A Prospective Study

    PubMed Central

    Ibrahim, Nurul Izzah; Ahmad, Mohd Sharkawi; Zulfarina, Mohamed S; Zaris, Sharifah Nurul Aqilah Sayed Mohd; Mohamed, Isa Naina; Mohamed, Norazlina; Mokhtar, Sabarul Afian; Shuid, Ahmad Nazrun

    2018-01-01

    Fracture is a type of musculoskeletal injury that contributes to an inability to perform daily activities. The objective of this study was to evaluate activities of daily living (ADL) of older adult patients with lower body fracture and to determine factors influencing ADL. Patient’s ADL was assessed at pre-fracture, ward admission and post-discharge phases using the Katz ADL questionnaire. There were 129 subjects at pre-fracture and ward phases and 89 subjects at discharge phase. There were four independent variables; age, gender, type of fracture and ability to walk before fracture. Logistic regression models showed that ‘age’ and ‘ability to walk before fracture’ were the determinant factors of dependent for ‘bathing’, ‘dressing’ and ‘toileting’. The ‘ability to walk before fracture’ was the determinant factor of dependent for ‘transferring’. ‘Age’ and ‘gender’ were the determinant factors of dependent for ‘continence’, while ‘age’ was the determinant factor of dependent for ‘feeding’. The ADL score changes were significant across the phases with a reduction in ADL score in the ward admission phase and partial increment during the post-discharge phase. There were improvements in the health outcomes of subjects aged more than 50 years old after 3 months of being discharged from the hospital. In conclusion, age, being female, having a hip fracture and using a walking aid before fracture were the determinants identified in this study. PMID:29772744

  6. Periprosthetic Fractures Following Total Knee Arthroplasty

    PubMed Central

    Kim, Nam Ki

    2015-01-01

    Periprosthetic fractures after total knee arthroplasty may occur in any part of the femur, tibia and patella, and the most common pattern involves the supracondylar area of the distal femur. Supracondylar periprosthetic fractures frequently occur above a well-fixed prosthesis, and risk factors include anterior femoral cortical notching and use of the rotational constrained implant. Periprosthetic tibial fractures are frequently associated with loose components and malalignment or malposition of implants. Fractures of the patella are much less common and associated with rheumatoid arthritis, use of steroid, osteonecrosis and malalignment of implants. Most patients with periprosthetic fractures around the knee are the elderly with poor bone quality. There are many difficulties and increased risk of nonunion after treatment because reduction and internal fixation is interfered with by preexisting prosthesis and bone cement. Additionally, previous soft tissue injury is another disadvantageous condition for bone healing. Many authors reported good clinical outcomes after non-operative treatment of undisplaced or minimally displaced periprosthetic fractures; however, open reduction or revision arthroplasty was required in displaced fractures or fractures with unstable prosthesis. Periprosthetic fractures around the knee should be prevented by appropriate technique during total knee arthroplasty. Nevertheless, if a periprosthetic fracture occurs, an appropriate treatment method should be selected considering the stability of the prosthesis, displacement of fracture and bone quality. PMID:25750888

  7. The management of tibial pilon fractures with the Ilizarov fixator: The role of ankle arthroscopy.

    PubMed

    El-Mowafi, Hani; El-Hawary, Ahmed; Kandil, Yasser

    2015-12-01

    Pilon fractures usually result from high energy trauma, and are commonly associated with extensive soft tissue damage which prevents the use of open reduction and internal fixation. This study was designed to evaluate the use of the Ilizarov external fixator in the treatment of pilon fractures of the ankle, and to determine whether arthroscopy of the ankle could improve the outcome. From February 2011 to May 2013 a total of 23 patients with unilateral closed pilon fractures were divided into two groups treated with and without arthroscopy during fixation with the Ilizarov external fixator. The fractures were classified according to the AO Rüdi and Allgőwer classification. Follow up ranged from 10 to 37 months with a mean of 18 months. All cases were evaluated at follow up by the AOFAS and the Bone et al. grading system. According to Bone et al. there were 3 cases excellent, 4 cases good, 2 cases fair, and 2 cases poor in Group A (without arthroscopy), whereas there were 4 cases excellent, 6 cases good, 2 cases fair in Group B (with arthroscopy). The AOFAS score for Group A was 77.8±5.8, and for Group B was 78.4±6.9. We concluded that the Ilizarov external fixator is an excellent method in treating pilon fractures as it minimizes the need for extensive surgery. We also conclude that the use of arthroscopy during pilon fracture fixation did not add statistically significant improvement to our results and it needs longer term investigation to assess its advantage - if any - to the final outcome. level 2. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Ipsilateral fracture dislocation of the shoulder and elbow: A case report and literature review

    PubMed Central

    Behr, Ian; Blint, Andy; Trenhaile, Scott

    2013-01-01

    Ipsilateral dislocation of the shoulder and elbow is an uncommon injury. A literature review identified nine previously described cases. We are reporting a unique case of ipsilateral posterior shoulder dislocation and anterior elbow dislocation along with concomitant intra-articular fractures of both joints. This is the first report describing this combination of injuries. Successful treatment generally occurs with closed reduction of ipsilateral shoulder and elbow dislocations, usually reducing the elbow first. When combined with a fracture at one or both locations, closed reduction of the dislocations in conjunction with appropriate fracture management can result in a positive functional outcome. PMID:26403884

  9. Modified tension band wiring fixation for avulsion fractures of the calcaneus in osteoporotic bone: a review of three patients.

    PubMed

    Nagura, Issei; Fujioka, Hiroyuki; Kurosaka, Masahiro; Mori, Hiroyuki; Mitani, Makoto; Ozaki, Akihiro; Fujii, Hideo; Nabeshima, Yuji

    2012-01-01

    Calcaneal avulsion fractures are not uncommon, and they are probably more likely in patients with osteoporosis. Closed manipulation for this type of fracture often fails to achieve acceptable reduction, and open reduction and internal fixation are usually required. However, open reduction and internal fixation with either a lag screw or Steinmann pins do not provide satisfactory fixation in patients with diabetes and elderly patients because of the presence of porotic bone. Levi described a tension band fixation system used to treat a calcaneal avulsion fracture using a simple technique performed with a transverse Kirschner wire through the os calcaneus, securing a figure-of-8 metal tension band wiring to the fragment. We report the successful treatment of 3 patients with calcaneal avulsion fractures using a modified tension band wiring technique, resulting in satisfactory recovery. Re-displacement of the fragment during the initial follow-up period was not reported, and bony union was achieved in all patients. We believe this technique is a useful surgical option for the treatment of calcaneal avulsion fractures. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Does age of fracture affect the outcome of vertebroplasty? Results from data from a prospective multicenter FDA IDE study.

    PubMed

    Syed, Mubin I; Shaikh, Azim

    2012-11-01

    To evaluate whether the age of a fracture is a variable that can identify patients for whom vertebroplasty would be most beneficial. Data from 256 patients with painful osteoporotic vertebral compression fractures (VCFs) who underwent vertebroplasty were examined to assess the effect of fracture age on outcomes. Patients ranged in age from 34-76 years, and the age of fractures ranged from 6 weeks or less (n = 117) to more than 52 weeks (n = 3). Most patients had a fracture age of 12 weeks or less (n = 207), with only 17% having a fracture age greater than 12 weeks. The duration of back pain was used as a surrogate for fracture age and was confirmed by edema on magnetic resonance (MR) imaging, abnormal bone scans, and the presence of central pain over the spinous process The primary outcome was pain reduction as determined by the change in the visual analog scale (VAS) pain score from baseline and at 1, 3, 6, and 24 months after vertebroplasty. A fracture age of 12 weeks or less versus greater than 12 weeks did not affect outcomes, with patients in both groups achieving equivalent benefit after vertebroplasty. Patients with a fracture age of 6 weeks or less had a slightly improved benefit at 3 months after vertebroplasty compared with those having a fracture age of greater than 6 weeks, but the benefit beyond 3 months was the same. Results of the study showed that the age of a fracture does not independently affect the outcomes of vertebroplasty. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  11. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  12. Early experience with a novel nonmetallic cable in reconstructive hip surgery.

    PubMed

    Ting, Nicholas T; Wera, Glenn D; Levine, Brett R; Della Valle, Craig J

    2010-09-01

    Metallic wires and cables are commonly used in primary and revision THA for fixation of periprosthetic fractures and osteotomies of the greater trochanter. These systems provide secure fixation and high healing rates but fraying, third-body generation, accelerated wear of the bearing surface, and injury to the surgical team remain concerning. We determined the rate of cable failure, union, and complications associated with a novel, nonmetallic cerclage cable in periprosthetic fracture and osteotomy fixation during THA. We retrospectively reviewed 29 patients who had primary and revision THAs using nonmetallic cables. Indications for use included fixation of an extended trochanteric osteotomy, intraoperative fracture of the proximal femur, strut allograft fixation, and a Vancouver B1 periprosthetic fracture of the femur. All patients were evaluated clinically and radiographically immediately postoperatively, at 3 weeks, 6 weeks, 3 months, and then annually thereafter. The minimum followup was 13 months (mean, 21 months; range, 13-30 months). Two of the 29 patients (7%) developed a nonunion; all remaining osteotomies, fractures and allografts had healed at the time of most recent evaluation. Four patients (14%) dislocated postoperatively; two were treated successfully with closed reduction, while the other two required reoperation. We identified no evidence of breakage or other complications directly attributable to the cables. The nonmetallic periprosthetic cables used in this series provided adequate fixation to allow for both osteotomy and fracture healing. We did not observe any complications directly related to the cables. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  13. Using Free Navigation Reference Points and Prefabricated Bone Plates for Zygoma Fracture Model Surgeries.

    PubMed

    Wang, Tien-Hsiang; Ma, Hsu; Tseng, Ching-Shiow; Chou, Yi-Hong; Cai, Kun-Lin

    Surgical navigation systems have been an important tool in maxillofacial surgery, helping surgeons create a presurgical plan, locate lesions, and provide guidance. For secondary facial bone reductions, a good presurgical plan and proper execution are the key to success. Previous studies used predetermined markers and screw holes as navigation references; however, unexpected situations may occur, making the predetermined surgical plan unreliable. Instead of determining positions preoperatively, this study proposes a method that surgeons can use intraoperatively to choose surface markers in a more flexible manner. Eight zygomatic fractures were created in four skull models, and preoperative computed tomography (CT) image data were imported into a self-developed navigation program for presurgical planning. This program also calculates the ideal positions of navigation references points for screw holes. During reduction surgery, markers on fractured bone are selected, registered, and calculated as free navigation reference points (FNRPs). The surface markers and FNRPs are used to monitor the position of the dislocated bone. Titanium bone plates were prefabricated on stereolithography models for osteosynthesis. Two reductions with only FNRPs, as well as six reductions with FNRPs and prefabricated bone plates, were successfully performed. Postoperative CT data were obtained, and surgical errors in the six-reduction group were evaluated. The average deviation from the screw hole drilling positions was 0.92 ± 0.38 mm. The average deviation included displacement and rotation of the zygomas. The mean displacement was 0.83 ± 0.38 mm, and the average rotations around the x, y, and z axes were 0.66 ± 0.59°, 0.77 ± 0.54°, and 0.79 ± 0.42°, respectively. The results show that combining presurgical planning and the developed navigation program to generate FNRPs for assisting in secondary zygoma reduction is an accurate and practical method. Further study is necessary to prove its clinical value.

  14. Proppant flowback control additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, P.D.; Weaver, J.D.; Parker, M.A.

    1996-12-31

    This paper describes the laboratory and field development of thermoplastic film materials used to reduce proppant flowback that can occur after fracturing treatments. The paper provides a summary of flowback mechanism theories and laboratory tests comparing flowback tendency for various types of treating procedures and materials. Some of these materials include angular proppant, proppant/fiber mixtures, and proppant with film strips tested over a wide range of temperature, closure stress, and flow-rate conditions. Field treatment procedures are discussed, and several case histories are presented. All of the methods evaluated were effective in reducing proppant flowback under certain conditions. Heat-shrink film cutmore » into thin slivers proved to provide flowback reduction over broad temperature and closure stress ranges and was found to cause little impairment to fracture conductivity with some dependency on use concentration, temperature, and closure stress. The film materials were more resistant to damage caused by blending and pumping than all other materials evaluated. In addition, proppant packs, including consolidated packs, were significantly more tolerant of large, repeated stress changes. Field results indicate that the use of the heat-shrink film material as a flowback control agent permits more aggressive bean-up procedures following conventional fracturing treatments. Conventional dry-additive metering systems were used to add the film material to the fracturing fluid proppant slurry.« less

  15. Strain rate effects on fracture behavior of Austempered Ductile Irons

    NASA Astrophysics Data System (ADS)

    Ruggiero, Andrew; Bonora, Nicola; Gentile, Domenico; Iannitti, Gianluca; Testa, Gabriel; Hörnqvist Colliander, Magnus; Masaggia, Stefano; Vettore, Federico

    2017-06-01

    Austempered Ductile Irons (ADIs), combining high strength, good ductility and low density, are candidates to be a suitable alternative to high-strength steels. Nevertheless, the concern about a low ductility under dynamic loads often leads designers to exclude cast irons for structural applications. However, results from dynamic tensile tests contradict this perception showing larger failure strain with respect to quasistatic data. The fracture behaviour of ADIs depends on damage mechanisms occurring in the spheroids of graphite, in the matrix and at their interface, with the matrix (ausferrite) consisting of acicular ferrite in carbon-enriched austenite. Here, a detailed microstructural analysis was performed on the ADI 1050-6 deformed under different conditions of strain rates, temperatures, and states of stress. Beside the smooth specimens used for uniaxial tensile tests, round notched bars to evaluate the ductility reduction with increasing stress triaxiality and tophat geometries to evaluate the propensity to shear localization and the associated microstructural alterations were tested. The aim of the work is to link the mechanical and fracture behavior of ADIs to the load condition through the microstructural modifications that occur for the corresponding deformation path.

  16. Orthopaedic traumatology: fundamental principles and current controversies for the acute care surgeon

    PubMed Central

    Pharaon, Shad K; Schoch, Shawn; Marchand, Lucas; Mirza, Amer

    2018-01-01

    Multiply injured patients with fractures are co-managed by acute care surgeons and orthopaedic surgeons. In most centers, orthopaedic surgeons definitively manage fractures, but preliminary management, including washouts, splinting, reductions, and external fixations, may be performed by selected acute care surgeons. The acute care surgeon should have a working knowledge of orthopaedic terminology to communicate with colleagues effectively. They should have an understanding of the composition of bone, periosteum, and cartilage, and their reaction when there is an injury. Fractures are usually fixed urgently, but some multiply injured patients are better served with a damage control strategy. Extremity compartment syndrome should be suspected in all critically injured patients with or without fractures and a low threshold for compartment pressure measurements or empiric fasciotomy maintained. Acute care surgeons performing rib fracture fixation and other chest wall injury reconstructions should follow the principles of open fracture reduction and stabilization. PMID:29766123

  17. Orthopaedic traumatology: fundamental principles and current controversies for the acute care surgeon.

    PubMed

    Pharaon, Shad K; Schoch, Shawn; Marchand, Lucas; Mirza, Amer; Mayberry, John

    2018-01-01

    Multiply injured patients with fractures are co-managed by acute care surgeons and orthopaedic surgeons. In most centers, orthopaedic surgeons definitively manage fractures, but preliminary management, including washouts, splinting, reductions, and external fixations, may be performed by selected acute care surgeons. The acute care surgeon should have a working knowledge of orthopaedic terminology to communicate with colleagues effectively. They should have an understanding of the composition of bone, periosteum, and cartilage, and their reaction when there is an injury. Fractures are usually fixed urgently, but some multiply injured patients are better served with a damage control strategy. Extremity compartment syndrome should be suspected in all critically injured patients with or without fractures and a low threshold for compartment pressure measurements or empiric fasciotomy maintained. Acute care surgeons performing rib fracture fixation and other chest wall injury reconstructions should follow the principles of open fracture reduction and stabilization.

  18. [Isolated Displaced Fracture of the Acromion - Case Report].

    PubMed

    Krtička, M; Ira, D

    2016-01-01

    Displaced fractures of the acromion are rare injuries. A 45-year-old lady presented with an isolated acromion fracture (type III, Kuhn classification) resulting from a direct blow to the top of her right shoulder in a fall while skiing. After standard clinical and radiological examination of the shoulder, an open reduction and internal plate fixation using a postero-superior approach to the scapula was performed. Early rehabilitation of the arm and shoulder was initiated. At 50 days after surgery the patient achieved a full range of motion in her right shoulder and muscle strength equal to that of the contralateral extremity. By 12 weeks radiographic union of the fracture was recorded. The final functional outcome after open reduction and internal plate fixation of the fracture was comparable with results reported in the literature and, in comparison with conservative treatment, the risk of non-union was significantly reduced. acromion fracture, scapula, osteosynthesis.

  19. [Progress on treatment and research of quadrilateral plate fractures of acetabular].

    PubMed

    Peng, Ye; Zhang, Li-hai; Tang, Pei-fu

    2015-05-01

    Acetabular is an important human joint for weight bearing. Quadrilateral plate is a crucial structure of medial acetabulum with special morphology and important function. Quadrilateral plate fractures are common fracture in acetabulum. Quadrilateral plate fracture is hard to expose and reduction because it is in the medial of acetabulum. At the same time,the bone in the quadrilateral plate is not easy to fixed for thinning bones and adjacent to the articular cavity. The operator should know well about the anatomy and choose the suitable internal fixation. After quadrilateral plate fractures, the femur head maybe displace medially even break into pelvis. That make reduction and treatment always be a challenge. With different kinds of fractures,the efficacy of treatment is not the same. This paper intend to review the relation of anatomic features,approaches, internal fixations, key point of treatment and efficacy.

  20. A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

    NASA Technical Reports Server (NTRS)

    Czabaj, Michael W.; Davidson, Barry D.; Ratcliffe, James G.

    2016-01-01

    Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

  1. Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate).

    PubMed

    Biazzo, Alessio; Cardile, Carlo; Brunelli, Luca; Ragni, Paolo; Clementi, Daniele

    2017-04-28

    The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (OrthofixR, Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature.

  2. Analysis of functional outcome of Hoffa fractures: A retrospective review of 32 patients.

    PubMed

    Trikha, Vivek; Das, Saubhik; Gaba, Sahil; Agrawal, Prabhat

    2017-01-01

    Hoffa fractures are uncommon intra-articular fractures of femoral condyle in coronal plane. The purpose of our study is to assess radiologic and functional outcome in operatively treated Hoffa fractures. We retrospectively reviewed 32 patients of isolated Hoffa fracture from January 2010 to March 2015. All were treated with open reduction and internal fixation using lateral approach for lateral Hoffa and medial approach for medial Hoffa fracture. Cancellous screws in lag mode and/or antiglide plate were employed for fixation in accordance with fracture anatomy. All patients were subjected to aggressive physical therapy postoperatively. Knee Society Score (KSS), International Knee Documentation Committee Score (IKDC), and Knee range of motion (ROM) were documented at final follow-up for functional evaluation. All fractures united by mean time of 11.56 ± 1.5 weeks. No evidence of subsequent displacement or fixation failure, arthritis, Avascular necrosis (AVN) of femoral condyle was elicited in any of the patients. Documented mean KSS and mean IKDC Score at final follow-up were 83.19 ± 8.43 and 81.62± 6.95, respectively. ROM at final follow-up was ranging from 0° to mean 116.41° ± 13.98°. Complications included stiffness of the involved knee in four patients, including one patient who developed infection and had to undergo implant removal after fracture union. Operative treatment of Hoffa fractures yields fairly good functional outcome. One must endeavor to achieve adequate intraoperative exposure and stable congruous articular reconstruction. Early aggressive physical therapy is a harbinger of optimal outcome.

  3. Optimisation of composite bone plates for ulnar transverse fractures.

    PubMed

    Chakladar, N D; Harper, L T; Parsons, A J

    2016-04-01

    Metallic bone plates are commonly used for arm bone fractures where conservative treatment (casts) cannot provide adequate support and compression at the fracture site. These plates, made of stainless steel or titanium alloys, tend to shield stress transfer at the fracture site and delay the bone healing rate. This study investigates the feasibility of adopting advanced composite materials to overcome stress shielding effects by optimising the geometry and mechanical properties of the plate to match more closely to the bone. An ulnar transverse fracture is characterised and finite element techniques are employed to investigate the feasibility of a composite-plated fractured bone construct over a stainless steel equivalent. Numerical models of intact and fractured bones are analysed and the mechanical behaviour is found to agree with experimental data. The mechanical properties are tailored to produce an optimised composite plate, offering a 25% reduction in length and a 70% reduction in mass. The optimised design may help to reduce stress shielding and increase bone healing rates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Evaluation on the cost-effective threshold of osteoporosis treatment on elderly women in China using discrete event simulation model.

    PubMed

    Ni, W; Jiang, Y

    2017-02-01

    This study used a simulation model to determine the cost-effective threshold of fracture risk to treat osteoporosis among elderly Chinese women. Osteoporosis treatment is cost-effective among average-risk women who are at least 75 years old and above-average-risk women who are younger than 75 years old. Aging of the Chinese population is imposing increasing economic burden of osteoporosis. This study evaluated the cost-effectiveness of osteoporosis treatment among the senior Chinese women population. A discrete event simulation model using age-specific probabilities of hip fracture, clinical vertebral fracture, wrist fracture, humerus fracture, and other fracture; costs (2015 US dollars); and quality-adjusted life years (QALYs) was used to assess the cost-effectiveness of osteoporosis treatment. Incremental cost-effectiveness ratio (ICER) was calculated. The willingness to pay (WTP) for a QALY in China was compared with the calculated ICER to decide the cost-effectiveness. To determine the absolute 10-year hip fracture probability at which the osteoporosis treatment became cost-effective, average age-specific probabilities for all fractures were multiplied by a relative risk (RR) that was systematically varied from 0 to 10 until the WTP threshold was observed for treatment relative to no intervention. Sensitivity analyses were also performed to evaluate the impacts from WTP and annual treatment costs. In baseline analysis, simulated ICERs were higher than the WTP threshold among Chinese women younger than 75, but much lower than the WTP among the older population. Sensitivity analyses indicated that cost-effectiveness could vary due to a higher WTP threshold or a lower annual treatment cost. A 30 % increase in WTP or a 30 % reduction in annual treatment costs will make osteoporosis treatment cost-effective for Chinese women population from 55 to 85. The current study provides evidence that osteoporosis treatment is cost-effective among a subpopulation of Chinese senior women. The results also indicate that the cost-effectiveness of using osteoporosis treatment is sensitive to the WTP threshold and annual treatment costs.

  5. Inverted distal clavicle anatomic locking plate for displaced medial clavicle fracture.

    PubMed

    Wang, Yong; Jiang, Jiannong; Dou, Bin; Zhang, Panjun

    2015-09-01

    Fractures of the medial clavicle are rare injuries. Recently, open reduction and internal fixation has been recommended for displaced medial clavicle fractures in order to prevent non-union and dysfunction. Because of the rarity of this injury, the optimal fixation device has not yet been established. In this report, we describe a case of a 40-year-old male patient who sustained a significantly displaced medial clavicle fracture treated by open reduction and internal fixation using an inverted distal clavicle anatomic locking plate. At the 12 months follow-up, the patient recovered well, had returned to pre-injury job, and was quite satisfied with the outcome. Internal fixation of medial clavicle fracture using an inverted distal clavicle anatomic locking plate of the ipsilateral side appears to be a good treatment option.

  6. Simultaneous Middle Third Clavicle Fracture and Type 3 Acromioclavicular Joint Dislocation; A Case Report

    PubMed Central

    Solooki, Saeed; Azad, Ali

    2014-01-01

    Simultaneous middle third clavicle fracture and acromioclavicular joint dislocation is a rare combination injury, as a result of high-energy trauma. We report a patient with a middle third clavicle fracture and ipsilateral grade three-acromioclavicular joint dislocation, which is a rare combination. The patient wanted to get back to work as soon as possible, so the fracture was fixed with reconstruction plate after open reduction and plate contouring; and acromioclavicular joint dislocation was reduced and fixed with two full threaded cancellous screws. One screw was inserted through the plate to the coracoid process. Clinical and radiographic finding revealed complete union of clavicle fracture and anatomical reduction of acromioclavicular joint with pain free full joint range of motion one year after operation. PMID:25207318

  7. Is fibular fracture displacement consistent with tibiotalar displacement?

    PubMed

    van den Bekerom, Michel P J; van Dijk, C Niek

    2010-04-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle fractures is based on the notion of elevated intraarticular contact pressures with lateral displacement. To diagnose these injuries, we presumed that in patients with a fibular fracture with at least 2 mm fracture displacement, the lateral malleolus and talus have moved at least 2 mm in a lateral direction without medial displacement of the proximal fibula. We reviewed 55 adult patients treated operatively for a supination-external rotation II ankle fracture (2 mm or more fibular fracture displacement) between 1990 and 1998. On standard radiographs, distance from the tibia to the proximal fibula, distance from the tibia to the distal fibula, and displacement at the level of the fibular fracture were measured. These distances were compared preoperatively and postoperatively. We concluded tibiotalar displacement cannot be reliably assessed at the level of the fracture. Based on this and other studies, we believe there is little evidence to perform open reduction and internal fixation of supination-external rotation II ankle fractures. Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.

  8. Radiographic diagnosis of sagittal plane rotational displacement in pelvic fractures: a cadaveric model and clinical case study.

    PubMed

    Shui, Xiaolong; Ying, Xiaozhou; Kong, Jianzhong; Feng, Yongzeng; Hu, Wei; Guo, Xiaoshan; Wang, Gang

    2015-08-01

    Our objective was to measure the sagittal plane rotational (flexion and extension) displacement of hemipelvis radiologically and analyze the ratio of flexion and extension displacement of unstable pelvic fractures. We used 8 cadaveric models to study the radiographic evidence of pelvic fractures in the sagittal plane. We performed pelvic osteotomy on 8 cadavers to simulate anterior and posterior pelvic ring injury. Radiological data were measured in the flexion and extension group under different angles (5°, 10°, 15°, 20°, and 25°). We retrospectively reviewed 164 patients who were diagnosed with a unilateral fracture of the pelvis. Pelvic ring displacement was identified and recorded radiographically in cadaveric models. The flexion and extension displacement of pelvic fractures was measured in terms of the vertical distance of fracture from the top of iliac crest to the pubic tubercle (CD) or from the top of iliac crest to the lowest point of ischial tuberosity (AB). Fifty-seven pelves showed flexion displacement and 15 showed extension displacement. Closed reduction including internal fixation and external fixation was successfully used in 141 cases (86.0 %). The success rates of closed reduction in flexion and extension displacement groups were 77 and 73 %, respectively, which were lower than in unstable pelvic ring fractures. The sagittal plane rotation (flexion and extension) displacement of pelvic fractures could be measured by special points and lines on the radiographs. Minimally invasive reduction should be based on clearly identified differences between the sagittal plane rotation and the vertical displacement of pelvic fractures.

  9. Miniplate for osteosynthesis in a 9-year-old with symphysis fracture: clinical report.

    PubMed

    Srinivasan, Ila; Kumar, Naveen; Jaganathan, Udhya; Bhandari, Arihant

    2013-09-01

    Osteosynthesis using minimum material in pediatric mandibular fractures is the key, due to the limited space available in the mandible, especially in the mental foramen and apical region. There is an important role of open reduction and rigid internal fixation in re-establishing facial height, width and projection. During the early years of growth and development, there is a high osteogenic potential of the bones. The thick periosteum allows for rapid consolidation and remodeling at the site of fracture. Primary teeth have short, bulbous crowns which compromise stable maxillomandibular fixation during fracture reduction and stabilization using traditional methods. Further, stability of the fractured segments may be hampered because of the displaced or mobile permanent anterior teeth in the mixed dentition along the line of fracture. This clinical report outlines the use of miniplate with monocortical screws in a 9-year-old boy with symphysis fracture. How to cite this article: Srinivasan I, Kumar N, Jaganathan U, Bhandari A. Miniplate for Osteosynthesis in a 9-Year-Old with Symphysis Fracture: Clinical Report. Int J Clin Pediatr Dent 2013;6(3):213-216.

  10. Management of distal humeral coronal shear fractures

    PubMed Central

    Yari, Shahram S; Bowers, Nathan L; Craig, Miguel A; Reichel, Lee M

    2015-01-01

    Coronal shear fractures of the distal humerus are rare, complex fractures that can be technically challenging to manage. They usually result from a low-energy fall and direct compression of the distal humerus by the radial head in a hyper-extended or semi-flexed elbow or from spontaneous reduction of a posterolateral subluxation or dislocation. Due to the small number of soft tissue attachments at this site, almost all of these fractures are displaced. The incidence of distal humeral coronal shear fractures is higher among women because of the higher rate of osteoporosis in women and the difference in carrying angle between men and women. Distal humeral coronal shear fractures may occur in isolation, may be part of a complex elbow injury, or may be associated with injuries proximal or distal to the elbow. An associated lateral collateral ligament injury is seen in up to 40% and an associated radial head fracture is seen in up to 30% of these fractures. Given the complex nature of distal humeral coronal shear fractures, there is preference for operative management. Operative fixation leads to stable anatomic reduction, restores articular congruity, and allows initiation of early range-of-motion movements in the majority of cases. Several surgical exposure and fixation techniques are available to reconstruct the articular surface following distal humeral coronal shear fractures. The lateral extensile approach and fixation with countersunk headless compression screws placed in an anterior-to-posterior fashion are commonly used. We have found a two-incision approach (direct anterior and lateral) that results in less soft tissue dissection and better outcomes than the lateral extensile approach in our experience. Stiffness, pain, articular incongruity, arthritis, and ulnohumeral instability may result if reduction is non-anatomic or if fixation fails. PMID:25984515

  11. Fracture Risk and Areal Bone Mineral Density in Adolescent Females with Anorexia Nervosa

    PubMed Central

    Faje, Alexander T.; Fazeli, Pouneh K.; Miller, Karen K.; Katzman, Debra K.; Ebrahimi, Seda; Lee, Hang; Mendes, Nara; Snelgrove, Deirdre; Meenaghan, Erinne; Misra, Madhusmita; Klibanski, Anne

    2014-01-01

    Objective To (i) compare fracture prevalence in adolescent females with anorexia nervosa (AN) vs. normal-weight controls and (ii) examine whether reductions in areal bone mineral density (aBMD) predict fracture risk in females with AN. Methods 418 females (310 with active AN and 108 normal-weight controls) 12–22 years old were studied cross-sectionally. Lifetime fracture history was recorded by a physician during participant interviews. Body composition and aBMD measurements of the whole body, whole body less head, lumbar spine, and hip were assessed by dual-energy x-ray absorptiometry (DXA), and bone mineral apparent density (BMAD) was calculated for the lumbar spine. Results Participants with AN and normal-weight controls did not differ for chronological age, sexual maturity, or height. The lifetime prevalence of prior fracture was 59.8% higher in those with AN compared to controls (31.0 % versus 19.4 %, p = 0.02), and the fracture incidence rate peaked in our cohort after the diagnosis of AN. Lower aBMD and lumbar BMAD were not associated with a higher prevalence of fracture in the AN or control group on univariate or multivariate analyses. Compared to controls, fracture prevalence was significantly higher in the subgroup of girls with AN who had normal aBMD or only modest reductions of aBMD (Z-scores > −1 or −1.5). Discussion This is the first study to show that the risk of fracture during childhood and adolescence is significantly higher in patients with AN than in normal-weight controls. Fracture prevalence is increased in this cohort of subjects with AN even without significant reductions in aBMD. PMID:24430890

  12. Fracture risk and areal bone mineral density in adolescent females with anorexia nervosa.

    PubMed

    Faje, Alexander T; Fazeli, Pouneh K; Miller, Karen K; Katzman, Debra K; Ebrahimi, Seda; Lee, Hang; Mendes, Nara; Snelgrove, Deirdre; Meenaghan, Erinne; Misra, Madhusmita; Klibanski, Anne

    2014-07-01

    To (i) compare fracture prevalence in adolescent females with anorexia nervosa (AN) versus normal-weight controls and (ii) examine whether reductions in areal bone mineral density (aBMD) predict fracture risk in females with AN. Four-hundred eighteen females (310 with active AN and 108 normal-weight controls) 12- to 22-years-old were studied cross-sectionally. Lifetime fracture history was recorded by a physician during participant interviews. Body composition and aBMD measurements of the whole body, whole body less head, lumbar spine, and hip were assessed by dual-energy X-ray absorptiometry, and bone mineral apparent density (BMAD) was calculated for the lumbar spine. Participants with AN and normal-weight controls did not differ for chronological age, sexual maturity, or height. The lifetime prevalence of prior fracture was 59.8% higher in those with AN as compared to controls (31.0% vs. 19.4%, p = 0.02), and the fracture incidence rate peaked in our cohort after the diagnosis of AN. Lower aBMD and lumbar BMAD were not associated with a higher prevalence of fracture in the AN or control group on univariate or multivariate analyses. Compared to controls, fracture prevalence was significantly higher in the subgroup of girls with AN who had normal aBMD or only modest reductions of aBMD (Z-scores > -1 or -1.5). This is the first study to show that the risk of fracture during childhood and adolescence is significantly higher in patients with AN than in normal-weight controls. Fracture prevalence is increased in this cohort of participants with AN even without significant reductions in aBMD. © 2014 Wiley Periodicals, Inc.

  13. Biomechanics of halo-vest and dens screw fixation for type II odontoid fracture.

    PubMed

    Ivancic, Paul C; Beauchman, Naseem N; Mo, Fred; Lawrence, Brandon D

    2009-03-01

    An in vitro biomechanical study of halo-vest and odontoid screw fixation of Type II dens fracture. The objective were to determine upper cervical spine instability due to simulated dens fracture and investigate stability provided by the halo-vest and odontoid screw, applied individually and combined. Previous studies have evaluated posterior fixation techniques for stabilizing dens fracture. No previous biomechanical study has investigated the halo-vest and odontoid screw for stabilizing dens fracture. A biofidelic skull-neck-thorax model was used with 5 osteoligamentous whole cervical spine specimens. Three-dimensional flexibility tests were performed on the specimens while intact, following simulated dens fracture, and following application of the halo-vest alone, odontoid screw alone, and halo-vest and screw combined. Average total neutral zone and total ranges of motion at C0/1 and C1/2 were computed for each experimental condition and statistically compared with physiologic motion limits, obtained from the intact flexibility test. Significance was set at P < 0.05 with a trend toward significance at P < 0.1. Type II dens fracture caused trends toward increased sagittal neutral zone and lateral bending range of motion at C1/2. Spinal motions with the dens screw alone could not be differentiated from physiologic limits. Significant reductions in motion were observed at C0/1 and C1/2 in flexion-extension and axial rotation due to the halo-vest, applied individually or combined with the dens screw. At C1/2, the halo-vest combined with the dens screw generally allowed the smallest average percentages of intact motion: 3% in axial rotation, 17% in flexion-extension, and 18% in lateral bending. The present reduction in C1/2 motion observed, due to the halo-vest and dens screw combined is similar to previously reported immobilization provided by the polyaxial screw/rod system and transarticular screw fixation combined with wiring. The present biomechanical data may be useful to clinicians when choosing an appropriate treatment for those with Type II dens fracture.

  14. Radiographic Measurement of Displacement in Acetabular Fractures: A Systematic Review of the Literature.

    PubMed

    Dodd, Andrew; Osterhoff, Georg; Guy, Pierre; Lefaivre, Kelly A

    2016-06-01

    To report methods of measurement of radiographic displacement and radiographic outcomes in acetabular fractures described in the literature. A systematic review of the English literature was performed using EMBASE and Medline in August 2014. Inclusion criteria were studies of operatively treated acetabular fractures in adults with acute (<6 weeks) open reduction and internal fixation that reported radiographic outcomes. Exclusion criteria included case series with <10 patients, fractures managed >6 weeks from injury, acute total hip arthroplasty, periprosthetic fractures, time frame of radiographic outcomes not stated, missing radiographic outcome data, and non-English language articles. Basic information collected included journal, author, year published, number of fractures, and fracture types. Specific data collected included radiographic outcome data, method of measuring radiographic displacement, and methods of interpreting or categorizing radiographic outcomes. The number of reproducible radiographic measurement techniques (2/64) and previously described radiographic interpretation methods (4) were recorded. One radiographic reduction grading criterion (Matta) was used nearly universally in articles that used previously described criteria. Overall, 70% of articles using this criteria documented anatomic reductions. The current standard of measuring radiographic displacement in publications dealing with acetabulum fractures almost universally lacks basic description, making further scientific rigor, such as testing reproducibility, impossible. Further work is necessary to standardize radiographic measurement techniques, test their reproducibility, and qualify their validity or determine which measurements are important to clinical outcomes. Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  15. Low-energy fracture of posterolateral tibial plateau: treatment by a posterolateral prone approach.

    PubMed

    Yu, Guang-Rong; Xia, Jiang; Zhou, Jia-Qian; Yang, Yun-Feng

    2012-05-01

    Most of the posterolateral tibial plateau fractures are caused by low-energy injury. The posterior fracture fragment could not be exposed and reduced well through traditional approaches. The aim of this study was to review the results of surgical treatment of this kind of fracture using posterolateral approach with patient in prone position. The low-energy posterolateral fracture is defined as the main part of articular depression or split fragment limited within the posterior half of the lateral column. Direct reduction and buttress plate fixation through the posterolateral prone approach was applied in all the patients. In our series, 15 of 132 (11.4%) patients with tibial plateau fractures were identified as low-energy posterolateral fractures. The clinical outcomes were available in 14 of the 15 patients through phone interviews and chart reviews. Mean follow-up was 35.1 months (range: 24-48 months). All the patients had anatomic or good reductions (≤ 2 mm step/gap). Average range of motion was 0.7 degrees to 123.2 degrees (5-110 degrees to 0-140 degrees). The complications were limited to one superficial wound infection, two slight flexion contractures, and five implants removal. The average modified hospital for special surgery knee score was 93.4 (range: 86-100). The posterolateral prone approach provides excellent visualization, which can facilitate the reduction and posterior buttress plate fixation for low-energy posterolateral tibial plateau fractures and shows encouraging results. V, therapeutic study.

  16. Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures.

    PubMed

    Tian, Yun; Zhou, Fang; Ji, Hongquan; Zhang, Zhishan; Guo, Yan

    2011-12-01

    Although the modified tension band technique (eg, tension band supplemented by longitudinal Kirschner wires) has long been the mainstay for fixation of transverse fractures of the patella, it has shortcomings, such as bad reduction, loosening of implants, and skin irritation. We conducted a retrospective comparison of the modified tension band technique and the titanium cable-cannulated screw tension band technique. We retrospectively reviewed 101 patients aged 22 to 85 years (mean, 56.6 years) with AO/OTA 34-C1 fractures (n = 68) and 34-C2 fractures (n = 33). Fifty-two patients were in the modified tension band group and 49 were in the titanium cable-cannulated screw tension band group. Followup was at least 1 year (range, 1-3 years). Comparison criteria were fracture reduction, fracture healing time, and the Iowa score for knee function. The titanium cable-cannulated screw tension band group showed improved fracture reduction, reduced healing time, and better Iowa score, compared with the modified tension band group. In the modified tension band group, eight patients experienced wire migration, three of these requiring a second operation. There were no complications in the titanium cable-cannulated screw tension band group. The titanium cable-cannulated screw tension band technique showed superior results and should be considered as an alternative method for treatment of transverse patellar fractures. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  17. Application of 3D Printing in the Surgical Planning of Trimalleolar Fracture and Doctor-Patient Communication.

    PubMed

    Yang, Long; Shang, Xian-Wen; Fan, Jian-Nan; He, Zhi-Xu; Wang, Jian-Ji; Liu, Miao; Zhuang, Yong; Ye, Chuan

    2016-01-01

    To evaluate the effect of 3D printing in treating trimalleolar fractures and its roles in physician-patient communication, thirty patients with trimalleolar fractures were randomly divided into the 3D printing assisted-design operation group (Group A) and the no-3D printing assisted-design group (Group B). In Group A, 3D printing was used by the surgeons to produce a prototype of the actual fracture to guide the surgical treatment. All patients underwent open reduction and internal fixation. A questionnaire was designed for doctors and patients to verify the verisimilitude and effectiveness of the 3D-printed prototype. Meanwhile, the operation time and the intraoperative blood loss were compared between the two groups. The fracture prototypes were accurately printed, and the average overall score of the verisimilitude and effectiveness of the 3D-printed prototypes was relatively high. Both the operation time and the intraoperative blood loss in Group A were less than those in Group B (P < 0.05). Patient satisfaction using the 3D-printed prototype and the communication score were 9.3 ± 0.6 points. A 3D-printed prototype can faithfully reflect the anatomy of the fracture site; it can effectively help the doctors plan the operation and represent an effective tool for physician-patient communication.

  18. Effect of Porosity on Deformation, Damage, and Fracture of Cast Steel

    NASA Astrophysics Data System (ADS)

    Hardin, R. A.; Beckermann, C.

    2013-12-01

    A combined experimental and computational study is performed to investigate the effect of centerline shrinkage porosity on deformation, damage, and fracture of cast steel under tensile testing. Steel plates containing shrinkage porosity are cast in sand molds, machined into test coupons, and tensile tested to fracture. The average volumetric porosity in the gage section of the specimens with porosity ranges from 0.10 to 0.27 pct. Ductility in the test castings with porosity is markedly reduced with the percent elongation data ranging from 12.8 to 19.6 pct; vs 22 pct elongation for the sound material. Radiographic imaging is used to measure and reconstruct the porosity field in the test specimens. The reconstructed porosity field is then used in a finite-element stress analysis simulating the tensile testing. Local elastic properties are reduced according to the porosity fraction present. Porous metal plasticity theory is used to model the damage due to porosity and the fracture. Good agreement is obtained between the measured and predicted stress-strain curves and fracture behaviors. The reduction in ductility is predicted well by comparing the measured and the simulated elongations. The computational modeling approach used in this study allows for a detailed evaluation of the effect of porosity, including its size, shape, and location, on the fracture behavior of steel castings.

  19. Avoidance of malreduction of proximal femoral shaft fractures with the use of a minimally invasive nail insertion technique (MINIT).

    PubMed

    Russell, Thomas A; Mir, Hassan R; Stoneback, Jason; Cohen, Jose; Downs, Brandon

    2008-07-01

    To determine our rate of malalignment in proximal femoral shaft fractures treated with intramedullary (IM) nails, with and without the use of a minimally invasive nail insertion technique (MINIT). Retrospective study. Level 1 trauma center. Between July 1, 2003, and June 31, 2005, 100 consecutive proximal femoral shaft fractures (97 patients) were treated with IM nails. The average age of the 56 men and 41 women was 43.5 years (range, 17 to 96 years). There were 92 closed fractures and 8 open fractures. Fractures were classified according to the Russell-Taylor classification (69 type 1A, 11 type 1B, 3 type 2A, 17 type 2B). All patients underwent antegrade IM nailing using a fracture table in the supine (83) or lateral (17) position. A total of 72 entry portals were trochanteric, and 28 were piriformis. Seventy-seven percent of the femurs were opened with MINIT, a technique that uses a percutaneous cannulated channel reamer over a guide pin as opposed to the standard method of Kuntscher, which employs a femoral awl. Nails were locked proximally using standard locking in 37 fractures, and recon mode in 63. Fracture reduction was examined on immediate postoperative films to determine angulation in the coronal and sagittal planes. Criteria for acceptable reduction were less than 5 degrees angulation in any plane. In addition, surgical position, entry portal, mechanism of injury, Russell-Taylor classification, OTA classification, open or closed fracture, open or closed reduction, and type of implant used were analyzed for significance. The frequency of malalignment was 10% for the entire group of patients. Malalignment occurred in 26% of fractures treated without the use of the MINIT and in 5.2% when the MINIT was used (P < 0.01). There was no statistically significant difference between the different Russell-Taylor fracture types, although there was a trend towards more malalignment in type 2A and 2B fractures (P = 0.06). None of the other factors studied had a statistically significant effect on malalignment. A whole-model test of the factors that were surgeon-controlled (use of the MINIT, surgical position, open or closed reduction, type of implant used, and entry portal) found that only use of the MINIT had a statistically significant effect on malalignment (P < 0.01). The results indicate that use of the minimally invasive nail insertion technique (MINIT) significantly decreases the occurrence of malalignment in proximal femoral shaft fractures.

  20. The use of resorbable plates in association with dental arch stabilization in the treatment of mandibular fractures in children.

    PubMed

    Li, Zhi; David, Ongodia; Li, Zu-Bing

    2014-07-01

    The purpose of this study was to investigate the effect of resorbable plate fixation in association with dental arch stabilization in the treatment of displaced mandibular fractures in children. Thirteen children (5 girls and 8 boys, age range 2 years 5 months to 12 years 2 months) with displaced mandibular fractures were included in this case series. Open reduction by intraoral approach was performed on these patients, and the fractures were fixed using resorbable plates and monocortical screws placed at the lower border of the mandible. At the same time, an arch bar or orthodontic wire splint was anchored using stainless steel wires or resin on the teeth to stabilize the whole mandibular dental arch. Postoperatively, follow-up was undertaken to evaluate the fracture healing, mandible movement, and mandible growth. Postoperatively, all patients achieved uneventful healing; premorbid occlusion restoration and wound healing were achieved, along with unimpaired function and normal growth and development of the mandible. Complications such as damage to tooth buds, infection, malunion, and nonunion were not encountered in these patients. Resorbable plates use in association with dental arch stabilization can provide good stabilization for mandibular fractures and is a promising approach for the treatment of displaced mandibular fractures in children. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Effect of the As-Forged and Heat-Treated Microstructure on the Room Temperature Anisotropic Ductile Fracture of Inconel 718

    NASA Astrophysics Data System (ADS)

    Teimouri, Javad; Hosseini, Seyed Rahman; Farmanesh, Khosro

    2018-05-01

    The purpose of the present work was to investigate the effect of primary carbides and the δ-phase on the anisotropic ductile fracture of Inconel 718 in the forging process. Inconel 718 alloys were prepared by VIM + VAR processes with various carbon contents (0.009 and 0.027 wt.%). Then, the alloys were forged and annealed at temperatures of 980 and 1030 °C. The room temperature mechanical anisotropy of the alloys was evaluated at the longitudinal direction (LD) and transverse direction (TD). Tensile and impact tests were used to characterize the mechanical properties of the specimens. The microstructural characterization and the fractography of the alloys were carried out by FE-SEM. The obtained results showed that the fracture strain and the impact energy in the TD were 30-50% lower than the LD. The fracture was accelerated by the δ-phase, leading to the reduction of impact energy in the longitudinal and the lateral directions up to 50%. The low-carbon alloy indicated similar characteristics in both the LD and the TD. Aligned carbides changed the fracture path from a zigzag path in the LD to a fibrous path in the TD, while the δ-phase created a flat fracture path. The shear lip area ratio in the tensile fracture cross section was decreased by reducing ductility.

  2. Effect of the As-Forged and Heat-Treated Microstructure on the Room Temperature Anisotropic Ductile Fracture of Inconel 718

    NASA Astrophysics Data System (ADS)

    Teimouri, Javad; Hosseini, Seyed Rahman; Farmanesh, Khosro

    2018-04-01

    The purpose of the present work was to investigate the effect of primary carbides and the δ-phase on the anisotropic ductile fracture of Inconel 718 in the forging process. Inconel 718 alloys were prepared by VIM + VAR processes with various carbon contents (0.009 and 0.027 wt.%). Then, the alloys were forged and annealed at temperatures of 980 and 1030 °C. The room temperature mechanical anisotropy of the alloys was evaluated at the longitudinal direction (LD) and transverse direction (TD). Tensile and impact tests were used to characterize the mechanical properties of the specimens. The microstructural characterization and the fractography of the alloys were carried out by FE-SEM. The obtained results showed that the fracture strain and the impact energy in the TD were 30-50% lower than the LD. The fracture was accelerated by the δ-phase, leading to the reduction of impact energy in the longitudinal and the lateral directions up to 50%. The low-carbon alloy indicated similar characteristics in both the LD and the TD. Aligned carbides changed the fracture path from a zigzag path in the LD to a fibrous path in the TD, while the δ-phase created a flat fracture path. The shear lip area ratio in the tensile fracture cross section was decreased by reducing ductility.

  3. Bovine xenograft application for treatment of a metatarsal nonunion fracture in an alpaca (Vicugna pacos).

    PubMed

    Longo, F; Finotti, L; Bellini, L; Zavan, B; Busetto, R; Isola, M

    2016-05-01

    A 15-year-old female huacaya alpaca (Vicugna pacos) was referred because of a non-weight-bearing lameness (4/4) in the left pelvic limb caused by a grade three open metatarsal fracture. The referring veterinarian treated the fracture with conservative management using bandages, but it progressively evolved to a non-union. Clinical examination revealed external wounds on the medial and lateral surfaces of the metatarsus. Radiographs confirmed an open, nonarticular, displaced, diaphyseal fracture of the left metatarsus. Cancellous bone was sourced from bovine proximal and distal femur epiphyses, followed by a thermal shock procedure to achieve decellularisation, to produce a xenograft. Open reduction and internal fixation of the fracture using locking plates was performed. Alignment of the fracture fragments was corrected and the xenograft was placed at the debrided fracture site to stimulate and harness osteogenesis in situ. Clinical and radiographic follow-up was performed up to 40 weeks postoperatively. Clinical evaluations revealed that the alpaca gradually increased weight bearing following bandage removal 10 days after surgery. Serial radiographs showed correct alignment of the left metatarsus, progressive bone modelling and, complete bone union at 12 weeks. Ten months postoperatively the alpaca showed no signs of lameness and resumed normal activity. For management of a metatarsal non-union, a combination of bovine xenograft application and angular stable internal fixation progressed toward an excellent long-term recovery.

  4. [Treatment of open tile type C pelvic fractures by open reduction and internal fixation through anterior and posterior approaches at early stage].

    PubMed

    Li, Baichuan

    2014-05-01

    To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.

  5. [The Postero-Lateral Approach--An Alternative to Closed Anterior-Posterior Screw Fixation of a Dislocated Postero-Lateral Fragment of the Distal Tibia in Complex Ankle Fractures].

    PubMed

    von Rüden, C; Hackl, S; Woltmann, A; Friederichs, J; Bühren, V; Hierholzer, C

    2015-06-01

    The dislocated posterolateral fragment of the distal tibia is considered as a key fragment for the successful reduction of comminuted ankle fractures. The reduction of this fragment can either be achieved indirectly by joint reduction using the technique of closed anterior-posterior screw fixation, or directly using the open posterolateral approach followed by plate fixation. The aim of this study was to compare the outcome after stabilization of the dislocated posterolateral tibia fragment using either closed reduction and screw fixation, or open reduction and plate fixation via the posterolateral approach in complex ankle fractures. In a prospective study between 01/2010 and 12/2012, all mono-injured patients with closed ankle fractures and dislocated posterolateral tibia fragments were assessed 12 months after osteosynthesis. Parameters included: size of the posterolateral tibia fragment relative to the tibial joint surface (CT scan, in %) as an indicator of injury severity, unreduced area of tibial joint surface postoperatively, treatment outcome assessed by using the "Ankle Fracture Scoring System" (AFSS), as well as epidemiological data and duration of the initial hospital treatment. In 11 patients (10 female, 1 male; age 51.6 ± 2.6 years [mean ± SEM], size of tibia fragment 42.1 ± 2.5 %) the fragment fixation was performed using a posterolateral approach. Impaired postoperative wound healing occurred in 2 patients of this group. In the comparison group, 12 patients were treated using the technique of closed anterior-posterior screw fixation (10 female, 2 male; age 59.5 ± 6.7 years, size of tibia fragment 45.9 ± 1.5 %). One patient of this group suffered an incomplete lesion of the superficial peroneal nerve. Radiological evaluation of the joint surface using CT scan imaging demonstrated significantly less dislocation of the tibial joint surface following the open posterolateral approach (0.60 ± 0.20 mm) compared to the closed anterior-posterior screw fixation (1.03 ± 0.08 mm; p < 0.05). Assessment of the treatment outcome using the AFSS demonstrated a significantly higher score of 97.4 ± 6.4 in the group with a posterolateral approach compared to a score of 74.4 ± 12.1 (p < 0.05) in the group with an anterior-posterior screw fixation. In comparison to the anterior-posterior screw fixation, open reduction and fixation of the dislocated, posterolateral key fragment of the distal tibia using a posterolateral approach resulted in a more accurate fracture reduction and significantly better functional outcome 12 months after surgery. In addition, no increased rate of postoperative complications, or extended hospital stay was observed but there was less severe post-traumatic joint arthritis. The results of this study suggest that in complex ankle factures the open fixation of the dislocated posterolateral fragment is recommended as an alternative surgical procedure and may be beneficial for both clinical and radiological long-term outcomes. Georg Thieme Verlag KG Stuttgart · New York.

  6. [An improved reduction technique for depression fractures of lateral tibial plateau].

    PubMed

    Wang, Hongchuan; Lou, Hua; Liu, Kai; Jiang, Junwei

    2013-01-01

    To investigate the improved reduction technique for depression fractures of the lateral tibial plateau and its effectiveness. Between January 2008 and December 2010; 48 patients (48 knees) with depression fractures of the lateral tibial plateau (Schatzker II or III fractures) were treated. There were 32 males and 16 females with an average age of 45.8 years (range, 16-79 years). All fractures were fresh closed fractures, which were caused by traffic accident in 27 cases, by falling from height in 5 cases, by crushing in 8 cases, and by sustained falls in 8 cases. According to Schatzker classification, 29 cases were classified as type II and 19 cases as type III. The lateral cortex was cut off to expose the depression and compacted cancellous bone was elevated to reset the articular surface. After reduction, autologous iliac bone graft and locking plate internal fixation were used. Healing of incision by first intention was achieved in all patients, and no complication occurred. All patients were followed up 1.7 years on average (range, 1-3 years). At last follow-up, the knee extension was (-0.5 +/- 0.3) degrees, and the knee flexion was (136.9 +/- 8.8) degrees. X-ray films showed that the fracture healing time was 52 weeks and no breakage of internal fixation occurred. According to Rasmussen clinical score, the results were excellent in 35 cases, good in 10 cases, and fair in 3 cases. According to Rasmussen radiographical score, the results were excellent in 41 cases, good in 7 cases; there were 41 excellent scores and 7 good scores of articular reduction; all gained good recovery of coronal and sagittal alignment and condylar width. The articular surface collapse was (1.0 +/- 0.7) mm at immediate postoperatively and (1.2 +/- 0.7) mm at last follow-up, showing no significant difference (t = -1.42, P = 0.20), but significant differences were found when compared with that at preoperation [(12.2 +/- 8.0) mm, P < 0.05]. This improved technique can provide a satisfactory effectiveness of fracture reduction and can avoid loss of reduction. The short-term effectiveness is good, but futher follow-up is necessary to determine the long-term results.

  7. Intramedullary nailing of humeral shaft fractures.

    PubMed

    Pickering, Robert M; Crenshaw, Andrew H; Zinar, Daniel M

    2002-01-01

    The development of interlocking humeral nail systems has greatly broadened the indications for nailing of humeral shaft fracture. Rotational control is better than with earlier nail systems, and most nails have an oblong distal hole that allows axial loading of the fracture site with muscle contraction. When nailing is done with closed technique, loss of the fracture hematoma and periosteal stripping are avoided. Even when open reduction is required, periosteal stripping can be kept to a minimum. Surgical wounds are smaller, even when open reduction is necessary, and when closed nailing is done, bone grafting is unnecessary. Intramedullary nails are ideal for segmental fractures, pathologic fractures, and fractures in osteopenic bone. Because the arm usually is not a weight-bearing extremity, hardware failure is rare and union rates are equivalent to those of compression plate and screw fixation. Compression plates and external fixation certainly have their place for some fracture patterns and for severe wounds that are unsuitable for intramedullary nailing. The surgeon should be well versed in all three techniques and should be able to rapidly choose among these, depending upon the fracture pattern, skin wound, associated injuries, and overall condition of the patient.

  8. Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial.

    PubMed

    Hannemann, Pascal; Göttgens, Kevin W A; van Wely, Bob J; Kolkman, Karel A; Werre, Andries J; Poeze, Martijn; Brink, Peter R G

    2011-05-06

    The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functional outcome. The scaphoid fracture is a troublesome fracture and failure of treatment can result in avascular necrosis (up to 40%), non-union (5-21%) and early osteo-arthritis (up to 32%) which may seriously impair wrist function. Impaired consolidation of scaphoid fractures results in longer immobilization and more days lost at work with significant psychosocial and financial consequences.Initially Pulsed Electromagnetic Fields was used in the treatment of tibial pseudoarthrosis and non-union. More recently there is evidence that physical forces can also be used in the treatment of fresh fractures, showing accelerated healing by 30% and 71% reduction in nonunion within 12 weeks after initiation of therapy. Until now no double blind randomized, placebo controlled trial has been conducted to investigate the effect of this treatment on the healing of fresh fractures of the scaphoid. This is a multi center, prospective, double blind, placebo controlled, randomized trial. Study population consists of all patients with unilateral acute scaphoid fracture. Pregnant women, patients having a life supporting implanted electronic device, patients with additional fractures of wrist, carpal or metacarpal bones and pre-existing impairment in wrist function are excluded. The scaphoid fracture is diagnosed by a combination of physical and radiographic examination (CT-scanning).Proven scaphoid fractures are treated with cast immobilization and a small Pulsed Electromagnetic Fields bone growth stimulating device placed on the cast. Half of the devices will be disabled at random in the factory.Study parameters are clinical consolidation, radiological consolidation evaluated by CT-scanning, functional status of the wrist, including assessment by means of the patient rated wrist evaluation (PRWE) questionnaire and quality of life using SF-36 health survey questionnaire.Primary endpoint is number of scaphoid unions at six weeks, secondary endpoints are time interval to clinical and radiological consolidation, number of non-unions, functional status at 52 weeks and non-adherence to the treatment protocol. Netherlands Trial Register (NTR): NTR2064. © 2011 Hannemann et al; licensee BioMed Central Ltd.

  9. Pulsed Electromagnetic Fields in the treatment of fresh scaphoid fractures. A multicenter, prospective, double blind, placebo controlled, randomized trial

    PubMed Central

    2011-01-01

    Background The scaphoid bone is the most commonly fractured of the carpal bones. In the Netherlands 90% of all carpal fractures is a fracture of the scaphoid bone. The scaphoid has an essential role in functionality of the wrist, acting as a pivot. Complications in healing can result in poor functional outcome. The scaphoid fracture is a troublesome fracture and failure of treatment can result in avascular necrosis (up to 40%), non-union (5-21%) and early osteo-arthritis (up to 32%) which may seriously impair wrist function. Impaired consolidation of scaphoid fractures results in longer immobilization and more days lost at work with significant psychosocial and financial consequences. Initially Pulsed Electromagnetic Fields was used in the treatment of tibial pseudoarthrosis and non-union. More recently there is evidence that physical forces can also be used in the treatment of fresh fractures, showing accelerated healing by 30% and 71% reduction in nonunion within 12 weeks after initiation of therapy. Until now no double blind randomized, placebo controlled trial has been conducted to investigate the effect of this treatment on the healing of fresh fractures of the scaphoid. Methods/Design This is a multi center, prospective, double blind, placebo controlled, randomized trial. Study population consists of all patients with unilateral acute scaphoid fracture. Pregnant women, patients having a life supporting implanted electronic device, patients with additional fractures of wrist, carpal or metacarpal bones and pre-existing impairment in wrist function are excluded. The scaphoid fracture is diagnosed by a combination of physical and radiographic examination (CT-scanning). Proven scaphoid fractures are treated with cast immobilization and a small Pulsed Electromagnetic Fields bone growth stimulating device placed on the cast. Half of the devices will be disabled at random in the factory. Study parameters are clinical consolidation, radiological consolidation evaluated by CT-scanning, functional status of the wrist, including assessment by means of the patient rated wrist evaluation (PRWE) questionnaire and quality of life using SF-36 health survey questionnaire. Primary endpoint is number of scaphoid unions at six weeks, secondary endpoints are time interval to clinical and radiological consolidation, number of non-unions, functional status at 52 weeks and non-adherence to the treatment protocol. Trial registration Netherlands Trial Register (NTR): NTR2064 PMID:21548951

  10. Definition of Mutually Optimum NDI and Proof Test Criteria for 2219 Aluminum Pressure Vessels. Volume 2: Optimization and Fracture Studies

    NASA Technical Reports Server (NTRS)

    Schwartzberg, F. R.; Toth, C., Jr.; King, R. G.; Todd, P. H., Jr.

    1979-01-01

    Certain behavioral aspects associated with fracture and crack extension that cannot be studied using other techniques were evaluated with the ultrasonic method. Characterization of collimated beam techniques showed that significant beam width reduction could be accomplished. Techniques for collimation are given. The crack-opening displacement-gage correction-factor study showed that displacement resulting from crack opening and that from plasticity could be readily differentiated. Crack closure studies using both ultrasonic and crack-opening displacement measurements showed an opening and closing behavior associated with load-unload curves. The results of this work were in general agreement with the closure concepts of Elber. Ultrasonic measurements used to study the nature of flaw extension characteristics associated with failure of the ligament between the flaw front and back surface showed that penetration could occur by an abrupt fracturing after subcritical growth or by continuous growth.

  11. Enhanced CAH dechlorination in a low permeability, variably-saturated medium

    USGS Publications Warehouse

    Martin, J.P.; Sorenson, K.S.; Peterson, L.N.; Brennan, R.A.; Werth, C.J.; Sanford, R.A.; Bures, G.H.; Taylor, C.J.; ,

    2002-01-01

    An innovative pilot-scale field test was performed to enhance the anaerobic reductive dechlorination (ARD) of chlorinated aliphatic hydrocarbons (CAHs) in a low permeability, variably-saturated formation. The selected technology combines the use of a hydraulic fracturing (fracking) technique with enhanced bioremediation through the creation of highly-permeable sand- and electron donor-filled fractures in the low permeability matrix. Chitin was selected as the electron donor because of its unique properties as a polymeric organic material and based on the results of lab studies that indicated its ability to support ARD. The distribution and impact of chitin- and sand-filled fractures to the system was evaluated using hydrologic, geophysical, and geochemical parameters. The results indicate that, where distributed, chitin favorably impacted redox conditions and supported enhanced ARD of CAHs. These results indicate that this technology may be a viable and cost-effective approach for remediation of low-permeability, variably saturated systems.

  12. Changing the surgical dogma in frontal sinus trauma: transnasal endoscopic repair.

    PubMed

    Grayson, Jessica W; Jeyarajan, Hari; Illing, Elisa A; Cho, Do-Yeon; Riley, Kristen O; Woodworth, Bradford A

    2017-05-01

    Management of frontal sinus trauma includes coronal or direct open approaches through skin incisions to either ablate or obliterate the frontal sinus for posterior table fractures and openly reduce/internally fixate fractured anterior tables. The objective of this prospective case-series study was to evaluate outcomes of frontal sinus anterior and posterior table trauma using endoscopic techniques. Prospective evaluation of patients undergoing surgery for frontal sinus fractures was performed. Data were collected regarding demographics, etiology, technique, operative site, length involving the posterior table, size of skull base defects, complications, and clinical follow-up. Forty-six patients (average age, 42 years) with frontal sinus fractures were treated using endoscopic techniques from 2008 to 2016. Mean follow-up was 26 (range, 0.5 to 79) months. Patients were treated primarily with a Draf IIb frontal sinusotomies. Draf III was used in 8 patients. Average fracture defect (length vs width) was 17.1 × 9.1 mm, and the average length involving the posterior table was 13.1 mm. Skull base defects were covered with either nasoseptal flaps or free tissue grafts. One individual required Draf IIb revision, but all sinuses were patent on final examination and all closed reductions of anterior table defects resulted in cosmetically acceptable outcomes. Frontal sinus trauma has traditionally been treated using open approaches. Our findings show that endoscopic management should become part of the management algorithm for frontal sinus trauma, which challenges current surgical dogma regarding mandatory open approaches. © 2017 ARS-AAOA, LLC.

  13. Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students

    PubMed Central

    Duran-Sindreu, Fernando; Morello-Castro, Sergio; Mercade-Bellido, Montserrat; Bueno-Martínez, Rufino; Roig-Cayón, Miguel

    2012-01-01

    Objective: To evaluate the effect of number of uses, angle and radius of curvature and type of instrument on the fracture of ProTaper rotary instruments when used by undergraduate students. Study Design: Three hundred and seventy-six molars, with a total of 1114 root canals, extracted were instrumented by undergraduate students using ProTaper instruments according to the manufacturer´s recommendations. When fracture occurred, data were collected concerning the number of uses, type of instrument, level of fracture, angle and radius of curvature. ANOVA test were used to determine the influence of type of instrument in the incidence of instrument fracture. Logistic regression model was used to determine the influence of number of uses, angle and radius of curvature in the incidence of instrument fracture. Significance was set at p< 0.05. Results: A total of 37 Ni-Ti rotary instruments fractured during the treatment. Fracture occurred in 9.84% (37/376) of the teeth treated and 3.32% of the canals prepared with Ni-Ti rotary instruments (37/1114). A decrease in the radius of curvature of the canal significantly increased the likelihood of fracture (p=0.0001). Instrument fracture significantly increased as the number of uses increased (p=0.0037). No significant differences were found between the 6 types of ProTaper instruments (p=0.8). A reduction in the angle of curvature did not produce a significant decrease in the incidence of instrument separation (p=0.08). Conclusions: The results of this study imply that instrument fracture is linked to radius of curvature and number of uses. Key words:Fracture, ProTaper ®, root canal preparation, undergraduate students. PMID:24558555

  14. Relationship between distal radius fracture malunion and arm-related disability: A prospective population-based cohort study with 1-year follow-up

    PubMed Central

    2011-01-01

    Background Distal radius fracture is a common injury and may result in substantial dysfunction and pain. The purpose was to investigate the relationship between distal radius fracture malunion and arm-related disability. Methods The prospective population-based cohort study included 143 consecutive patients above 18 years with an acute distal radius fracture treated with closed reduction and either cast (55 patients) or external and/or percutaneous pin fixation (88 patients). The patients were evaluated with the disabilities of the arm, shoulder and hand (DASH) questionnaire at baseline (concerning disabilities before fracture) and one year after fracture. The 1-year follow-up included the SF-12 health status questionnaire and clinical and radiographic examinations. Patients were classified into three hypothesized severity categories based on fracture malunion; no malunion, malunion involving either dorsal tilt (>10 degrees) or ulnar variance (≥1 mm), and combined malunion involving both dorsal tilt and ulnar variance. Multivariate regression analyses were performed to determine the relationship between the 1-year DASH score and malunion and the relative risk (RR) of obtaining DASH score ≥15 and the number needed to harm (NNH) were calculated. Results The mean DASH score at one year after fracture was significantly higher by a minimum of 10 points with each malunion severity category. The RR for persistent disability was 2.5 if the fracture healed with malunion involving either dorsal tilt or ulnar variance and 3.7 if the fracture healed with combined malunion. The NNH was 2.5 (95% CI 1.8-5.4). Malunion had a statistically significant relationship with worse SF-12 score (physical health) and grip strength. Conclusion Malunion after distal radius fracture was associated with higher arm-related disability regardless of age. PMID:21232088

  15. The evolution of selective estrogen receptor modulators in osteoporosis therapy

    PubMed Central

    2012-01-01

    Selective estrogen receptor modulators (SERMs), which exhibit estrogen receptor agonist or antagonist activity based on the target tissue, have evolved through multiple generations for the prevention and/or treatment of postmenopausal osteoporosis. An ideal SERM would protect bone without stimulating the breast or endometrium. Raloxifene, lasofoxifene, and bazedoxifene have demonstrated unique preclinical profiles. Raloxifene, lasofoxifene, and bazedoxifene have shown significant reduction in the risk of vertebral fracture and improvement in bone mineral density versus placebo in postmenopausal women with osteoporosis. Raloxifene has been shown to reduce the risk of non-vertebral fractures in women with severe prevalent fractures at baseline. Lasofoxifene 0.5 mg, but not lasofoxifene 0.25 mg, has shown reduction in the incidence of non-vertebral fractures. Bazedoxifene 20 mg has been associated with a significant reduction in the risk of non-vertebral fracture versus placebo and raloxifene 60 mg in women at higher baseline fracture risk. Neither raloxifene, lasofoxifene, nor bazedoxifene has shown an increase in the incidence of endometrial hyperplasia or carcinoma. All SERMs have been associated with increased venous thromboembolic events and hot flushes. SERMs are effective alternatives for women who cannot tolerate or are unwilling to take bisphosphonates and may be appropriate for women at higher risk of fracture, particularly younger women who expect to remain on therapy for many years and are concerned about the long-term safety of bisphosphonates. PMID:22853318

  16. [Principles of management of periprosthetic fractures].

    PubMed

    Röderer, G; Gebhard, F; Scola, A

    2016-03-01

    The increasing numbers of primary total hip and knee replacements have subsequently led to growing rates of periprosthetic fractures. In many cases geriatric patients with osteopenia or osteoporotic bone quality are affected. The goal of treatment is the retention or reconstruction of joint function using open reduction and internal fixation or a revision prosthesis. The aim of this article is a description of the basic principles of treatment of periprosthetic fractures of the lower extremities. An exact description of the fracture using current classification systems with imaging diagnostics is mandatory. This also includes an assessment of the stability of the prosthesis. In the case of a stable prosthesis and a good bone stock open reduction and internal fixation should be performed. In these cases locking plates are standard procedure. If fracture reduction is possible minimally invasive procedures can be performed which help to reduce the surgical trauma and accelerate rehabilitation. If the prosthesis is loose it has to be exchanged for a revision implant. If vast bony defects result they can be augmented using wedges. Conservative treatment plays only a subordinate role in selected cases. Periprosthetic fractures show an increasing incidence and occur more frequently in the geriatric patient population. Due to comorbidities and poor bone quality surgical treatment is a challenge. The fracture must be exactly classified using the appropriate classification system in order to clarify if the prosthesis can be retained or if it has to be exchanged.

  17. SURGICAL MANAGEMENT OF APPENDICULAR LONG-BONE FRACTURES IN FREE-RANGING FLORIDA PANTHERS ( PUMA CONCOLOR CORYI): SIX CASES (2000-2014).

    PubMed

    Au Yong, Jo Anne; Lewis, Daniel D; Citino, Scott B; Cunningham, Mark W; Cross, Alan R; Farese, James P; Pablo, Luisito S

    2018-03-01

    The clinical outcomes of six free-ranging Florida panthers ( Puma concolor coryi) that underwent surgical stabilization of appendicular long-bone fractures (three femoral fractures, one tibial and one tibial and fibular fracture and two radial and ulnar fractures) were evaluated. These panthers presented to the University of Florida from 2000-2014. Estimated age of the panthers ranged from 0.5 to 4.5 yr, and weights ranged from 22 to 65 kg. Causes of injuries were vehicular collision ( n = 4) and capture related ( n = 2). All panthers underwent open reduction and fracture stabilization. Fixation failure necessitated three subsequent surgeries in one panther. Five panthers survived the immediate postoperative period, and all of these panthers' fractures obtained radiographic union (range, 8-36 [mean, 22] wk). The five surviving panthers underwent convalescence for 7-14 mo at White Oak Conservation Center before being released back into the wild; however, one panther was killed when hit by a car 3 days after release. The remaining four panthers were tracked for up to 106 mo in the wild and successfully integrated back into the native population. Surgical stabilization of appendicular long-bone fractures in free-ranging Florida panthers can be successful, but must take into account the stress that a large, undomesticated felid will place on the stabilized limb during convalescence as well as the difficulties involved in rehabilitating a wild panther in captivity.

  18. Evaluation of an Image-Based Tool to Examine the Effect of Fracture Alignment and Joint Congruency on Outcomes after Wrist Fracture.

    PubMed

    Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C

    2015-01-01

    Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.

  19. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  20. Treatment of displaced intra-articular calcaneal fractures with triangular tube-to-bar external fixation: long-term clinical follow-up and radiographic analysis.

    PubMed

    Roukis, Thomas S; Wünschel, Markus; Lutz, Hans-Peter; Kirschner, Peter; Zgonis, Thomas

    2008-04-01

    Sixty-six feet (62 patients) with displaced intra-articular calcaneal fractures underwent manual reduction and distraction with the use of a triangular tube-to-bar external fixation device and were retrospectively reviewed at a minimum of 1-year post-operative. Final radiographic follow-up revealed complete consolidation in all fractures, maintenance of reduction, and limited degenerative osteoarthrosis about the subtalar joint. Our results indicate that with proper application and attention to detail, restoration of calcaneal morphology using triangular tube-to-bar external fixation should be considered a viable alternative in the treatment of displaced intra-articular fractures of the calcaneus.

  1. Hydraulic Fracturing and Production Optimization in Eagle Ford Shale Using Coupled Geomechanics and Fluid Flow Model

    NASA Astrophysics Data System (ADS)

    Suppachoknirun, Theerapat; Tutuncu, Azra N.

    2017-12-01

    With increasing production from shale gas and tight oil reservoirs, horizontal drilling and multistage hydraulic fracturing processes have become a routine procedure in unconventional field development efforts. Natural fractures play a critical role in hydraulic fracture growth, subsequently affecting stimulated reservoir volume and the production efficiency. Moreover, the existing fractures can also contribute to the pressure-dependent fluid leak-off during the operations. Hence, a reliable identification of the discrete fracture network covering the zone of interest prior to the hydraulic fracturing design needs to be incorporated into the hydraulic fracturing and reservoir simulations for realistic representation of the in situ reservoir conditions. In this research study, an integrated 3-D fracture and fluid flow model have been developed using a new approach to simulate the fluid flow and deliver reliable production forecasting in naturally fractured and hydraulically stimulated tight reservoirs. The model was created with three key modules. A complex 3-D discrete fracture network model introduces realistic natural fracture geometry with the associated fractured reservoir characteristics. A hydraulic fracturing model is created utilizing the discrete fracture network for simulation of the hydraulic fracture and flow in the complex discrete fracture network. Finally, a reservoir model with the production grid system is used allowing the user to efficiently perform the fluid flow simulation in tight formations with complex fracture networks. The complex discrete natural fracture model, the integrated discrete fracture model for the hydraulic fracturing, the fluid flow model, and the input dataset have been validated against microseismic fracture mapping and commingled production data obtained from a well pad with three horizontal production wells located in the Eagle Ford oil window in south Texas. Two other fracturing geometries were also evaluated to optimize the cumulative production and for the three wells individually. Significant reduction in the production rate in early production times is anticipated in tight reservoirs regardless of the fracturing techniques implemented. The simulations conducted using the alternating fracturing technique led to more oil production than when zipper fracturing was used for a 20-year production period. Yet, due to the decline experienced, the differences in cumulative production get smaller, and the alternating fracturing is not practically implementable while field application of zipper fracturing technique is more practical and widely used.

  2. [Locked volar plating for complex distal radius fractures: maintaining radial length].

    PubMed

    Jeudy, J; Pernin, J; Cronier, P; Talha, A; Massin, P

    2007-09-01

    Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the ulnar variance and radial angulation in the first six months postoperatively. The correction of the ulnar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.

  3. The Adult Monteggia Fracture: Patterns and Incidence of Annular Ligament Incarceration Among 121 Cases at a Single Institution Over 19 Years.

    PubMed

    Hamaker, Max; Zheng, Amy; Eglseder, W Andrew; Pensy, Raymond A

    2018-01-01

    The purposes of this study were to identify the relative frequency of Monteggia fracture patterns and to investigate the required frequency of open reduction of the proximal radiocapitellar joint. We identified 121 Monteggia fractures at a Level I trauma center from 1996 to 2015 and included 119 in this study. These fractures were identified using a database search for the appropriate International Classification of Diseases, Ninth Revision and Current Procedural Terminology codes as well as individual surgeons' logs. Two fellowship-trained hand surgeons reviewed the identified patients' x-rays and operative notes. Each fracture was classified using Bado's original description, excluding transolecranon and Monteggia variants. Bado I lesion represented 68% (81 of 119) of Monteggia fractures. Annular ligament incarceration preventing radial head reduction occurred in approximately 17% (14 of 81) of this Bado type. Revision fixation of the ulna was not necessary (none of 119 cases) and functional range of motion (average arc, 117°) was recovered in most patients. The reoperation rate of 20% (23 of 119) was related to the severity of the presenting injury and hardware prominence. Most radial head dislocations associated with Monteggia fractures occur anteriorly and will reduce with anatomic plating of the ulna. In cases where the radial head fails to reduce, entrapment of the annular ligament can be expected and open reduction is required. Revision fixation of the ulna to achieve reduction of the radial head is uncommon in our experience. Prognostic IV. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Burden of non-hip, non-vertebral fractures on quality of life in postmenopausal women: the Global Longitudinal study of Osteoporosis in Women (GLOW)

    PubMed Central

    Roux, C.; Wyman, A.; Hooven, F. H.; Gehlbach, S. H.; Adachi, J. D.; Chapurlat, R. D.; Compston, J. E.; Cooper, C.; Díez-Pérez, A.; Greenspan, S. L.; LaCroix, A. Z.; Netelenbos, J. C.; Pfeilschifter, J.; Rossini, M.; Saag, K. G.; Sambrook, P. N.; Silverman, S.; Siris, E. S.; Watts, N. B.; Boonen, S.

    2016-01-01

    Purpose Most fracture studies have focused on hip and vertebral fractures, but there is growing evidence that non-hip, non-vertebral (NHNV) fractures also result in substantial morbidity and healthcare costs. We sought to assess the effect of NHNV fractures on quality of life. Methods We analyzed 1-year incidences of hip, spine, major NHNV (pelvis/leg, shoulder/arm) and minor NHNV (wrist/hand, ankle/foot, rib/clavicle) fractures among women from the GLOW registry, a prospective, multinational, observational cohort study. Health-related quality of life (HRQL) was analyzed using EuroQol EQ-5D and the SF-36 health survey. Results Among 50,461 women analyzed, there were 1,822 fractures (57% minor NHNV, 26% major NHNV, 10% spine, 7% hip) over 1 year. Spine fractures had the greatest detrimental effect on EQ-5D summary scores, followed by major NHNV and hip fractures. The amount of women with mobility problems increased most for those with major NHNV and spine fractures (both +8%); spine fractures were associated with the largest increases in problems with self care (+11%), activities (+14%), and pain/discomfort (+12%). Decreases in physical function and health status were greatest for women with spine or hip fractures. Multivariable modeling found that EQ-5D reduction was greatest for spine fractures, followed by hip and major/minor NHNV. Significant reductions in SF-36 physical function were found only for spine and major NHNV fractures. Conclusion This prospective study shows that NHNV fractures have a detrimental effect on HRQL. As NHNV fractures account for >80% of incident fractures, efforts to optimize osteoporosis care should include prevention of NHNV fractures. PMID:22398855

  5. Remodeling of a nontreated displaced parasymphyseal fracture of a child.

    PubMed

    Kerem, Hakan; Usluer, Ayşen; Yoleri, Levent

    2011-07-01

    There have been considerable advances in the management of craniomaxillofacial injuries in children. Conservative approaches such as close observation, a liquid-to-soft diet, and analgesics can be used for the management of mandibular fractures without displacement and malocclusion. However, displaced fractures need to be an anatomic reduction and immobilization. The basic principle of displaced mandibular fractures in both children and adults is the stabilization of fracture fragments forming the pretraumatic contour and occlusion state until osteosynthesis occurs. The major differences of pediatric fractures from adults are the flexibility of bones and very rapid healing pattern. Therefore, reduction in pediatric age group must be accomplished earlier. This case was an 11-year-old boy presented with a severely displaced parasymphyseal mandibular fracture resulting from a fall. He was given a soft diet and analgesic, given anti-inflammatory treatment of edema, and scheduled for operation. Subsequently, it was surprisingly observed that there was a significant improvement in the fracture line on the 12th posttraumatic day. The comparison of maxillofacial computed tomographic scans of the first and 12th posttraumatic days revealed a noteworthy remodeling and a remarkable approximation of the fracture lines. It can be concluded that bone remodelization in the pediatric age groups is perfect and very rapid, even in severely displaced fractures.

  6. Motor function and activities of daily living capacity of patients with fractures sustained during the Wenchuan earthquake.

    PubMed

    Zhang, Jin-Long; He, Hong-Chen; Lin, Hai-Dan; Luo, Qing-Lu; Xia, Lu; Li, Sha-Sha; He, Cheng-Qi

    2011-05-01

    On the afternoon of May 12, 2008, a 8.0-magnitude earthquake hit Sichuan Province, a mountainous region in Western China, killing about 70 000 people and leaving over 18 000 missing. What about the survivors motor functions and activities of daily living (ADL) capacity, especially for fractures? We need the data to guide the rehabilitation for the seismic wounded and it's important to collect the data for the future. We study the survivors to understand the motor functions and ADL capacity of patients with fractures sustained in the Wenchuan earthquake, to provide a basis for rehabilitation and treatment. We used the Manual Muscle Testing method to evaluate muscle strength, the joint angle scale to measure joint range of motion (ROM), and the Barthel index to evaluate the activities of daily living status. SPSS 13.0 software was used to analyze the data and the results were tested using one-way analysis of variance (ANOVA). The number of seismic wounded amounted to 487; 81.1% of patients had fractures. Most of the injured had fractures in multiple regions (53.9% of all fracture patients), followed by fractures of the upper limb (34.0% of patients); cranial fractures were rare (2.3%). Totally 82.0% had restricted range of motion, 23.5% had decreased muscle force, and 72.2% of the patients had restricted activities of daily living capacities. With time the activities of daily living capacity of female increased (P < 0.05), compared with the male fracture patients who did not show any relative improvement (P > 0.05). The difference between the patients' ages and ADL capacities did not reach statistical significance (P > 0.05), nor was there a significant difference between their ages and the numbers of days in hospital (P > 0.05). Fractures were the main issue in the seismic wounded, many of them had reductions in the ROM, muscle force and ADL capacities. The physicians involved in rehabilitation should pay greater attention to muscle force exercises, joint mobilization, and occupational therapy during the early phases post disaster.

  7. Open reduction and internal fixation of mandibular fracture in an 11-month-old infant: a case report

    PubMed Central

    Kim, Tae-Wan; Seo, Eun-Woo

    2013-01-01

    Mandibular fractures in infants are rare. This case report describes management of a mandibular fracture in an 11-month-old infant using a microplate and screws with open reduction. The surgical treatment was successful. Because the bone fragments were displaced and only the primary incisors had erupted, conservative treatment, such as an acrylic splint and circummandibular wiring, was not recommended. Nine weeks after surgery, the microplate was removed. The results showed complete clinical and radiological bone healing with normal eruption of deciduous teeth. PMID:24471024

  8. A partitioned model order reduction approach to rationalise computational expenses in nonlinear fracture mechanics

    PubMed Central

    Kerfriden, P.; Goury, O.; Rabczuk, T.; Bordas, S.P.A.

    2013-01-01

    We propose in this paper a reduced order modelling technique based on domain partitioning for parametric problems of fracture. We show that coupling domain decomposition and projection-based model order reduction permits to focus the numerical effort where it is most needed: around the zones where damage propagates. No a priori knowledge of the damage pattern is required, the extraction of the corresponding spatial regions being based solely on algebra. The efficiency of the proposed approach is demonstrated numerically with an example relevant to engineering fracture. PMID:23750055

  9. Analysis of two different surgical approaches for fractures of the mandibular condyle.

    PubMed

    Kumaran, S; Thambiah, L J

    2012-01-01

    Fractures of the condyle account for one third of all the mandibular fractures. Different surgical approaches to the condyle described hitherto testify to the advantages and disadvantages of the different surgical techniques used for approaching the condyle in such cases of fractures. We have described and compared two of such surgical techniques in this study. The aim of this study is to compare the outcome of dealing with condylar fractures by two different surgical techniques: the mini retromandibular approach, and the preauricular approach. A prospective study of 31 patients who had suffered with mandibular condylar fractures was carried out. Of these, 26 patients had unilateral condylar fractures, and 5 patients had a bilateral fracture. Further, 19 of these patients were treated by the mini retromandibular approach and 12 by the preauricular approach. The treated patients were followed up and evaluated for a minimum period of 1 year and assessed for parameters such as the maximum mouth opening, lateral movement on the fractured side, mandibular movements such as protrusion, dental occlusion, scar formation, facial nerve weakness, salivary fistula formation and time taken for the completion of the surgical procedure. t- test was used for statistical analysis of the data obtained in the study. Dental occlusion was restored in all the cases, and good anatomical reduction was achieved. The mean operating time was higher 63.53 (mean) ± 18.12 minutes standard deviation (SD) in the preauricular approach compared to 45.22 (mean) ± 18.86 minutes SD in the mini retromandibular approach. Scar formation was satisfactory in almost all the cases.

  10. [Case-control study on transverse carpal ligament resection for the prevention of delayed carpal tunnel syndrome after distal radius fracture].

    PubMed

    Wang, Yan-jie; Wang, Shi-gang; Miao, Shu-juan; Su, Xia

    2011-06-01

    To investigate the effects of open reduction by palm side for the distal radius fracture and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection for the prevention of delayed carpal tunnel syndrome after operation. From March 2000 to March 2007, 32 patients (8 males and 24 females, ranging in age from 46 to 66 years) with distal radius fracture were treated with open reduction by palm side and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection; while 30 patients (7 males and 23 females,ranging in age from 45 to 65 years) only with open reduction by palm side and T shape plate internal fixation. The incidences of delayed carpal tunnel syndrome between the two groups were compared. Among 32 patients treated with open reduction by palm side and T shape plate internal fixation with anterior transverse carpal ligament resection, 3 patients had delayed carpal tunnel syndrome; while in 30 patients treated with open reduction by palm side and T shape plate internal fixation, 10 patients had delayed carpal tunnel syndrome. There was significant statistically difference (P < 0.05%). Simultaneous anterior transverse carpal ligament resection can effectively prevent the delayed carpal tunnel syndrome occurrence for the distal radius fracture with open reduction by palm side.

  11. Operative treatment of distal femoral fractures above total knee arthroplasty with the indirect reduction technique: a long-term follow-up study.

    PubMed

    Kolb, Klaus; Koller, Heiko; Lorenz, Ingo; Holz, Ulrich; Marx, Frank; Grützner, Paul; Kolb, Werner

    2009-04-01

    The complication rate of conventional plate osteosynthesis (CPO) of periprosthetic femoral fractures above total knee arthroplasties (TKA) is high. Indirect reduction techniques were introduced to reduce surgical dissection at the fracture site. Twenty-one patients (4 men and 17 women) with femoral fractures above well-fixed total knee arthroplasties were consecutively treated with the indirect reduction technique. AO/ASIF (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of the Problems of Internal Fixation) Type 33A fractures were included. The mean age was 78 years (range, 67-94 years). Four fractures were stabilised with bone grafts, three in combination with bone cement. Nineteen of the patients were seen at a 1-year follow-up, 15 were seen after a long-term follow-up of 9 years (range, 7-12 years). There was only one implant failure in a comminuted fracture with severe osteoporosis, no infection, and no non-union. At the 1-year follow-up malalignment of 5 degrees varus occurred in one patient. The mean range of motion of the eighteen patients was 98 degrees (range, 65-110 degrees). The mean knee society score was 74 (range, 62-84), the mean function score was 52 (range, 39-72). At the long-term follow-up, the mean range of motion of the patients was 101 degrees (range, 65-115 degrees). The mean knee society score was 77 (range, 65-88), the mean function score was 55 (range, 40-75). Our results suggest the 95 degrees condylar blade plate in the indirect reduction technique is still a good implant with good long-term results. It works best in proximal fractures when there is minimal comminution of the distal fragment in the hands of an experienced trauma surgeon. Knee function and range of motion increased less over time.

  12. Use of a Hybrid Operating Room to Improve Reduction of Syndesmotic Injuries in Ankle Fractures: A Case Report.

    PubMed

    Cancienne, Jourdan M; Crosen, Matelin P; Yarboro, Seth R

    2016-01-01

    Ankle fractures are one of the most common orthopedic injuries requiring operative treatment, and approximately 1 in 4 ankle fractures will have an associated distal tibiofibular syndesmosis disruption. Syndesmotic reduction is crucial to restoring ankle function and preventing the development of arthritis. The hybrid operating room provides 3-dimensional intraoperative imaging capabilities that can enable the surgeon to ensure the syndesmosis is appropriately reduced, particularly by comparing it with the contralateral ankle. By confirming the syndesmosis reduction intraoperatively, the risk of a return to the operating room for revision surgery is decreased. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    PubMed Central

    Vasiliadis, Elias S; Grivas, Theodoros B; Psarakis, Spyridon A; Papavasileiou, Evangelos; Kaspiris, Angelos; Triantafyllopoulos, Georgios

    2009-01-01

    Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate. PMID:19754962

  14. Early Rehabilitation of Distal Radius Fractures Stabilized by Volar Locking Plate: A Prospective Randomized Pilot Study

    PubMed Central

    Quadlbauer, Stefan; Pezzei, Christoph; Jurkowitsch, Josef; Kolmayr, Brigitta; Keuchel, Tina; Simon, Daniel; Hausner, Thomas; Leixnering, Martin

    2016-01-01

    Background Distal radius fractures are very common and an increased incidence of 50% is estimated by 2030. Therefore, both operative and postsurgical treatment remains pertinent. Main aim in treating intra-articular fractures is to restore the articular surface by internal fixation and early mobilization (EM). Questions/Purposes The purpose of this study was to compare functional results between EM immediately after surgery and 5 weeks of immobilization (IM). Patients and Methods In a randomized prospective study, 30 patients with an isolated distal radius fracture were treated by open reduction and internal fixation using a single volar locking plate excluding bone graft. Fifteen patients were randomized in the EM group and 15 in the IM group. At 6 weeks, 9 weeks, 3 months, 6 months, and 1 year postsurgery, range of motion, grip strength and X-rays were evaluated. Additionally, Quick Disability of the Arm, Shoulder and Hand (QuickDASH) questionnaire, Patient-Rated Wrist Evaluation (PRWE), modified Green O'Brien (Mayo) score, and pain according to the Visual Analog Scale score were analyzed. Results Patients in the EM group had a significantly better range of motion in the sagittal plane, in grip strength up to 6 months, in the frontal plane up to 9 weeks, and in forearm rotation up to 6 weeks. Also QuickDASH and PRWE scores were better up to 6 weeks postsurgery. The Green O'Brien score differed significantly up to 1 year. At 1 year, 93% “excellent” and “good” results in the Green O'Brien score with a mean QuickDASH of 5.98 ± 10.94 and PRWE score of 4.27 ± 9.23 were observed in the EM group. No differences regarding loss of reduction, pain, duration of physiotherapy, and sick leave were noted. Conclusion EM of surgically treated distal radius fractures (without bone graft) is a safe method for postoperative aftercare and leads to an improved range of motion and grip strength at 6 months postsurgery compared with an IM of 5 weeks. Level of Evidence This is a level Ib clinical study. PMID:28428911

  15. Comparison of various approaches for the treatment of fractures of the mandibular condylar process.

    PubMed

    Handschel, Jörg; Rüggeberg, Tim; Depprich, Rita; Schwarz, Frank; Meyer, Ulrich; Kübler, Norbert R; Naujoks, Christian

    2012-12-01

    Fractures of the mandibular condyle process are the most common fractures of the lower jaw. Unfortunately, the type of treatment is still a matter of debate. The aim of this investigation was to compare the outcome of different treatment approaches regarding function and surgical side-effects. 111 fractures of the mandibular condyle representing all types according to the classification of Spiessl and Schroll were included. Both closed reduction (CR) and open reduction with internal fixation (ORIF) including the retromandibular/transparotid, submandibular, preauricular and intraoral approach were performed. The clinical examination included functional and aesthetic aspects at least 1 year after the fracture. The majority of fractures (45%) were classified into Type II and IV according to Spiessl and Schroll followed by fractures without any displacement or dislocation (29.7%). The submandibular approach showed the worst outcome regarding permanent palsy of the facial nerve and hypertrophic scarring. No significant differences between the various approaches were detected in the functional status in any diagnosis group. Inferior condylar neck fractures benefit from ORIF by an intraoral approach whereas in high condylar neck fractures the retromandibular/transparotid approach shows the best results. Fractures of the condylar head were almost all treated by CR and our results cannot contribute to the debate of CR vs. ORIF in this type of fracture. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Arthroscopy-assisted reduction of posteromedial tibial plateau fractures with buttress plate and cannulated screw construct.

    PubMed

    Chiu, Chih-Hao; Cheng, Chun-Ying; Tsai, Min-Chain; Chang, Shih-Sheng; Chen, Alvin Chao-Yu; Chen, Yeung-Jen; Chan, Yi-Sheng

    2013-08-01

    To present the radiologic and clinical results of posteromedial fractures treated with arthroscopy-assisted reduction and buttress plate and cannulated screw fixation. Twenty-five patients with posteromedial tibial plateau fractures treated by the described technique were included in this study. According to the Schatzker classification, there were 5 type IV fractures (20%), 2 type V fractures (8%), and 18 type VI fractures (72%). The mean age at operation was 46 years (range, 21 to 79 years). The mean follow-up period was 86 months (range, 60 to 108 months). Clinical and radiologic outcomes were scored by the Rasmussen system. Subjective data were collected to assess swelling, difficulty climbing stairs, joint stability, ability to work and participate in sports, and overall patient satisfaction with recovery. Secondary osteoarthritis was diagnosed when radiographs showed a narrowed joint space in the injured knee at follow-up in comparison with the films taken at the time of injury. The mean postoperative Rasmussen clinical score was 25.9 (range, 18 to 29), and the mean radiologic score was 15.8 (range, 10 to 18). All 25 fractures achieved successful union, and 92% had good or excellent clinical and radiologic results. The 3 fracture types did not significantly differ in Rasmussen scores or rates of satisfactory results (P > .05). Secondary osteoarthritis was noted in 6 injured knees (24%). Arthroscopy-assisted reduction with buttress plate and cannulated screw fixation can restore posteromedial tibial plateau fractures of the knee with well-documented radiographic healing, good clinical outcomes, and low complication rates. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation.

    PubMed

    Kim, Ji Wan; Kim, Hyun Uk; Oh, Chang-Wug; Kim, Joon-Woo; Park, Ki Chul

    2018-01-01

    To compare the radiologic and clinical results of minimally invasive plate osteosynthesis (MIPO) and minimal open reduction and internal fixation (ORIF) for simple distal tibial fractures. Randomized prospective study. Three level 1 trauma centers. Fifty-eight patients with simple and distal tibial fractures were randomized into a MIPO group (treatment with MIPO; n = 29) or a minimal group (treatment with minimal ORIF; n = 29). These numbers were designed to define the rate of soft tissue complication; therefore, validation of superiority in union time or determination of differences in rates of delayed union was limited in this study. Simple distal tibial fractures treated with MIPO or minimal ORIF. The clinical outcome measurements included operative time, radiation exposure time, and soft tissue complications. To evaluate a patient's function, the American Orthopedic Foot and Ankle Society ankle score (AOFAS) was used. Radiologic measurements included fracture alignment, delayed union, and union time. All patients acquired bone union without any secondary intervention. The mean union time was 17.4 weeks and 16.3 weeks in the MIPO and minimal groups, respectively. There was 1 case of delayed union and 1 case of superficial infection in each group. The radiation exposure time was shorter in the minimal group than in the MIPO group. Coronal angulation showed a difference between both groups. The American Orthopedic Foot and Ankle Society ankle scores were 86.0 and 86.7 in the MIPO and minimal groups, respectively. Minimal ORIF resulted in similar outcomes, with no increased rate of soft tissue problems compared to MIPO. Both MIPO and minimal ORIF have high union rates and good functional outcomes for simple distal tibial fractures. Minimal ORIF did not result in increased rates of infection and wound dehiscence. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  18. Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model.

    PubMed

    Seeley, Mark A; Fabricant, Peter D; Lawrence, J Todd R

    2017-09-01

    Approximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement. A distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the realism of simulation. Eighteen participants consented to participate in the study (eight attending pediatric orthopaedic surgeons, six junior residents, four senior residents). The performances of junior residents (Postgraduate Year [PGY] 1-2), senior residents (PGY 3-5), and attending surgeons were compared using one-way ANOVA with Tukey's-adjusted pairwise comparisons. The majority of participants (15 of 18) felt that the model looked, felt, and moved like a human forearm. All participants strongly agreed that the model taught the basic steps of fracture reduction and should be implemented in orthopaedic training. Attending surgeons reduced fractures in less time than junior residents (60 ± 27 seconds versus 460 ± 62 seconds; mean difference, 400 seconds; 95% CI, 335-465 seconds; p < 0.001). Residual angulation was greater for junior residents when compared with attending surgeons on AP (7° ± 5° versus 0.7° ± 0.9°; mean difference, 6.3°; 95% CI, 3°-11°; p = 0.003) and lateral (27° ± 7° versus 7° ± 5°; mean difference, 20°; 95% CI, 13°-27°; p = 0.001) radiographs. Similarly, residual displacement was greater for junior residents than either senior residents (mean difference, 16 mm; 95% CI, 2-34 mm; p = 0.05) or attending surgeons (mean difference, 15 mm; 95% CI, 3-27 mm; p = 0.02) on lateral images. There were no differences identified in secondary performance variables (number of fluoroscopic images, casting time, and cast index) between groups. This is the first distal radius fracture reduction model to incorporate an elbow and shoulder and allow quantitative assessment of the fracture reduction. This simulator may be useful in an orthopaedic resident training program to help them reach a defined minimum level of competency. This simulator also could easily be integrated in other accreditation and training programs, including emergency medicine. Level II, therapeutic study.

  19. Evaluation of the effectiveness of toe board energy-absorbing material for foot, ankle, and lower leg injury reduction.

    PubMed

    Patalak, John P; Stitzel, Joel D

    2018-02-17

    Since 2000, numerous improvements have been made to the National Association for Stock Car Auto Racing, Incorporated (NASCAR®) driver restraint system, resulting in improved crash protection for motorsports drivers. Advancements have included seats, head and neck restraints (HNRs), seat belt restraint systems, driver helmets, and others. These enhancements have increased protection for drivers from severe crash loading. Extending protection to the driver's extremities remains challenging. Though the drivers' legs are well contained for lateral and vertical crashes, they remain largely unrestrained in frontal and frontal oblique crashes. Sled testing was conducted for the evaluation of an energy-absorbing (EA) toe board material to be used as a countermeasure for leg and foot injuries. Testing included baseline rigid toe boards, tests with EA material-covered toe boards, and pretest positioning of the 50th percentile male frontal Hybrid III anthropomorphic test device (ATD) lower extremities. ATD leg and foot instrumentation included foot acceleration and tibia forces and moments. The sled test data were evaluated using established injury criteria for tibial plateau fractures, leg shaft fractures, and calcaneus, talus, ankle, and midfoot fractures. A polyurethane EA foam was found to be effective in limiting axial tibia force and foot accelerations when subjected to frontal impacts using the NASCAR motorsport restraint system.

  20. Role of Chloride in the Corrosion and Fracture Behavior of Micro-Alloyed Steel in E80 Simulated Fuel Grade Ethanol Environment

    PubMed Central

    Joseph, Olufunmilayo O.; Loto, Cleophas A.; Sivaprasad, Seetharaman; Ajayi, John A.; Tarafder, Soumitra

    2016-01-01

    In this study, micro-alloyed steel (MAS) material normally used in the production of auto parts has been immersed in an E80 simulated fuel grade ethanol (SFGE) environment and its degradation mechanism in the presence of sodium chloride (NaCl) was evaluated. Corrosion behavior was determined through mass loss tests and electrochemical measurements with respect to a reference test in the absence of NaCl. Fracture behavior was determined via J-integral tests with three-point bend specimens at an ambient temperature of 27 °C. The mass loss of MAS increased in E80 with NaCl up to a concentration of 32 mg/L; beyond that threshold, the effect of increasing chloride was insignificant. MAS did not demonstrate distinct passivation behavior, as well as pitting potential with anodic polarization, in the range of the ethanol-chloride ratio. Chloride caused pitting in MAS. The fracture resistance of MAS reduced in E80 with increasing chloride. Crack tip blunting decreased with increasing chloride, thus accounting for the reduction in fracture toughness. PMID:28773601

  1. Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs.

    PubMed

    Watrous, Gwyneth K; Moens, Noel M M

    2017-04-01

    This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight < 9 kg, fracture of the radius and ulna with open reduction, and internal fixation utilizing a cuttable bone plate. Thirty-four fractures in 31 dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg.

  2. Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs

    PubMed Central

    Watrous, Gwyneth K.; Moens, Noel M.M.

    2017-01-01

    This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight < 9 kg, fracture of the radius and ulna with open reduction, and internal fixation utilizing a cuttable bone plate. Thirty-four fractures in 31 dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg. PMID:28373730

  3. Teaching facial fracture repair: A novel method of surgical skills training using three-dimensional biomodels.

    PubMed

    D'Souza, Neil; Mainprize, James; Edwards, Glenn; Binhammer, Paul; Antonyshyn, Oleh

    2015-01-01

    The facial fracture biomodel is a three-dimensional physical prototype of an actual facial fracture. The biomodel can be used as a novel teaching tool to facilitate technical skills training in fracture reduction and fixation, but more importantly, can help develop diagnostic and management competence. To introduce the 'facial fracture biomodel' as a teaching aid, and to provide preliminary evidence of its effectiveness in teaching residents the principles of panfacial fracture repair. Computer three-dimensional image processing and rapid prototyping were used to generate an accurate physical model of a panfacial fracture, mounted in a silicon 'soft tissue' base. Senior plastic surgery residents in their third, fourth and fifth years of training across Canada were invited to participate in a workshop using this biomodel to simulate panfacial fracture repair. A short didactic presentation outlining the 'patient's' clinical and radiological findings, and key principles of fracture repair, was given by a consultant plastic surgeon before the exercise. The residents completed a pre- and postbiomodel questionnaire soliciting information regarding background, diagnosis and management, and feedback. A total of 29 residents completed both pre- and postbiomodel questionnaires. Statistically significant results were found in the following areas: diagnosis of all fracture patterns (P=8.2×10(-7) [t test]), choice of incisions for adequate exposure (P=0.04 [t test]) and identifying sequence of repair (P=0.019 [χ(2) test]). Subjective evaluation of workshop effectiveness revealed a statistically significant increase in 'comfort level' only among third year trainees. Overall, positive feedback was reported among all participants. Biomodelling is a promising ancillary teaching aid that can assist in teaching residents technical skills, as well as how to assess and plan surgical repair.

  4. Clinical and radiographic outcomes of femoral head fractures: excision vs. fixation of fragment in Pipkin type I: what is the optimal choice for femoral head fracture?

    PubMed

    Park, Kyung-Soon; Lee, Keun-Bae; Na, Bo-Ram; Yoon, Taek-Rim

    2015-07-01

    In this work, we present relatively long-term results of femoral head fractures with a specific focus on Pipkin type I fractures. Fifty-nine femoral head fractures were treated according to modified Pipkin's classification as follows: type I, small fragment distal to the fovea centralis (FC); type II, large fragment distal to the FC; type III, large fragment proximal to the FC; type IV, comminuted fracture. There were 15 cases of type I, 28 of type II, 9 of type III, and 7 of type IV fractures. Conservative treatment with skeletal traction was performed in 4 type II cases, excision of the fragment in 15 type I and 10 type II cases, fixation of the fragment in 14 type II and all 9 type III cases, and total hip replacement in all 7 type IV cases. The overall clinical and radiographic outcomes were evaluated using previously published criteria, focusing on the results in Pipkin type I fractures with relatively large fragments. Based on Epstein criteria, in type II fractures, excellent or good clinical results were seen in 6 of 10 patients (60.0 %) treated by excision of the fragment and 12 of 14 patients (85.7 %) treated by internal fixation (p = 0.05). Also, excellent or good radiologic results were seen in 4 of 10 (40.0 %) patients treated by excision of the fragment and 12 of 14 (85.7 %) patients treated by internal fixation (p = 0.03). Even in Pipkin type I fractures, if the fragment is large (modified Pipkin type II), early reduction and internal fixation can produce good results.

  5. Measurement of Malrotation on Direct Radiography in Pediatric Distal Radius Fractures

    PubMed Central

    Duymus, Tahir Mutlu; Mutlu, Serhat; Komur, Baran; Mutlu, Harun; Yucel, Bulent; Parmaksizoglu, Atilla Sancar

    2016-01-01

    Abstract The aim of this prospective study was to test a mathematical method of measuring the malrotation of pediatric distal radius fractures (PDRFs) from direct radiographs. A total of 70 pediatric patients who presented at the Emergency Department with a distal radius fracture were evaluated. For 38 selected patients conservative treatment for PDRF was planned. Anteroposterior and lateral radiographs were taken of all of the patients for comparison before and after reduction. Radius bone diameters were measured in the coronal and sagittal planes on the healthy and fractured sides. Using the diameter values on the healthy side and the new diameter values on the fractured side in the rotation formula, the degree of malrotation between the fracture ends was calculated. The mean follow-up period was 13.5 months. Patients’ mean age was 10.00 ± 3.19 years (range, 4–12 years). The rotation degree in the sagittal plane significantly differed between the proximal (26.52°±2.84°) and distal fracture ends (20.96°±2.73°) (P = 0.001). The rotation degree in the coronal plane significantly differed between the proximal (26.70°±2.38°) and distal fracture ends (20.26°±2.86°) (P = 0.001). The net rotation deformity of the fracture line was determined to be 5.55°± 3.54° on lateral radiographs and 5.44°± 3.35° on anteroposterior radiographs, no significant difference was observed between measurements (P >0.05). The malrotation deformity in PDRF occurs with greater rotation in the proximal fragment than in the distal fragment. The net rotation deformity created between the fracture ends can be calculated on direct radiographs. Level of Evidence: Diagnostic, Level II PMID:27149480

  6. Assessing symmetry using the mirror stand device with manual and software-assisted methods in postoperative zygomatic fracture patients

    NASA Astrophysics Data System (ADS)

    Syarif, A. N.; Bangun, K.

    2017-08-01

    Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.

  7. Factors affecting length of stay after isolated femoral shaft fractures.

    PubMed

    Pendleton, Albert M; Cannada, Lisa K; Guerrero-Bejarano, Maria

    2007-03-01

    Controlling escalating health care costs is important for hospitals and has far reaching implications for society. Hospital length of stay (LOS) is one of the most reliable predictors of cost after trauma. Our purpose was to establish LOS after isolated femur fractures treated by intramedullary (IM) nail. The trauma registry was queried to identify patients. Patients were excluded if they required assistive ambulatory devices before injury, had chronic/terminal illness or compromised brain function. There were 102 patients with an average age of 27 years. Statistical analysis was completed. The average LOS was 3.9 days. In all, 27 patients stayed longer than 4 days. Reasons included social (7), medical (10), and hospital delays (10). The average time from arrival to surgery was 17 hours. The average time from surgery to physical therapy was 1.3 days. Patients who had surgery more than 24 hours after arrival stayed longer. Patients requiring placement stayed 2.4 days longer until placement was found. Factors the hospital can control to reduce LOS include time to surgery, time for physical therapy evaluation, and radiology delays (for spine clearance radiographs). Physical therapy availability within 24 hours of surgery is important and should include weekends and holidays. Early evaluation of social factors including homelessness or obstacles to independent living may reduce time to find placement. LOS reduction after femur fractures will decrease the cost of trauma to the hospital. In addition, LOS reduction will possibly increase bed availability and minimize the time spent on diversion yielding greater revenues and increasing patient satisfaction.

  8. Evaluating Stiffness of Fibreglass and Thermoplastic Splint Materials and Inter-fragmentary Motion in a Canine Tibial Fracture Model.

    PubMed

    Wagoner, Amanda L; Allen, Matthew J; Zindl, Claudia; Litsky, Alan; Orsher, Robert; Ben-Amotz, Ron

    2018-04-16

     Various materials are used to construct splints for mid-diaphyseal tibial fracture stabilization. The objective of this study was to compare construct stiffness and inter-fragmentary bone motion when fibreglass (FG) or thermoplastic (TP) splints are applied to either the lateral or cranial aspect of the tibia in a mid-diaphyseal fracture model.  A coaptation bandage was applied to eight cadaveric canine pelvic limbs, with a custom-formed splint made of either FG or TP material applied to either the lateral or cranial aspect of the osteotomized tibia. Four-point bending tests were performed to evaluate construct stiffness and inter-fragmentary motion in both frontal and sagittal planes.  For a given material, FG or TP, construct stiffness was not affected by splint location. Construct stiffness was significantly greater with cranial FG splints than with cranial TP splints ( p  < 0.05), but this difference was not significant when comparing splints applied laterally ( p  = 0.15). Inter-fragmentary motions in the sagittal and frontal planes were similar across splint types for cranial splints, but for lateral splints there was a 64% reduction in frontal plane motion when FG was used as the splint material ( p  = 0.03).  FG produces a stiffer construct, but the difference is not reflected in a reduction in inter-fragmentary motion. For lateral splints, FG splints are associated with reduced inter-fragmentary motion as compared with TP and may therefore have slight superiority for this application. Schattauer GmbH Stuttgart.

  9. Effect of tritium and decay helium on the fracture toughness properties of stainless steel weldments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, M. J.; West, S.; Tosten, M. H.

    2008-07-15

    J-Integral fracture toughness tests were conducted on tritium-exposed-and- aged Types 304L and 21-6-9 stainless steel weldments in order to measure the combined effects of tritium and its decay product, helium-3 on the fracture toughness properties. Initially, weldments have fracture toughness values about three times higher than base-metal values. Delta-ferrite phase in the weld microstructure improved toughness provided no tritium was present in the microstructure. After a tritium-exposure-and-aging treatment that resulted in {approx}1400 atomic parts per million (appm) dissolved tritium, both weldments and base metals had their fracture toughness values reduced to about the same level. The tritium effect was greatermore » in weldments (67 % reduction vs. 37% reduction) largely because the ductile discontinuous delta-ferrite phase was embrittled by tritium and decay helium. For both base metals and weldments, fracture toughness values decreased with increasing decay helium content in the range tested (50-800 appm). (authors)« less

  10. TRITIUM AND DECAY HELIUM EFFECTS ON THE FRACTURE TOUGHNESS PROPERTIES OF STAINLESS STEEL WELDMENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, M; Scott West, S; Michael Tosten, M

    2007-08-31

    J-Integral fracture toughness tests were conducted on tritium-exposed-and-aged Types 304L and 21-6-9 stainless steel weldments in order to measure the combined effects of tritium and its decay product, helium-3 on the fracture toughness properties. Initially, weldments have fracture toughness values about three times higher than base-metal values. Delta-ferrite phase in the weld microstructure improved toughness provided no tritium was present in the microstructure. After a tritium-exposure-and-aging treatment that resulted in {approx}1400 atomic parts per million (appm) dissolved tritium, both weldments and base metals had their fracture toughness values reduced to about the same level. The tritium effect was greater inmore » weldments (67 % reduction vs. 37% reduction) largely because the ductile discontinuous delta-ferrite interfaces were embrittled by tritium and decay helium. Fracture toughness values decreased for both base metals and weldments with increasing decay helium content in the range tested (50-200 appm).« less

  11. Osteoporosis: the emperor has no clothes

    PubMed Central

    Järvinen, T L N; Michaëlsson, K; Aspenberg, P; Sievänen, H

    2015-01-01

    Current prevention strategies for low-trauma fractures amongst older persons depend on the notions that fractures are mainly caused by osteoporosis (pathophysiology), that patients at high risk can be identified (screening) and that the risk is amenable to bone-targeted pharmacotherapy (treatment). However, all these three notions can be disputed. Pathophysiology Most fracture patients have fallen, but actually do not have osteoporosis. A high likelihood of falling, in turn, is attributable to an ageing-related decline in physical functioning and general frailty. Screening Currently available fracture risk prediction strategies including bone densitometry and multifactorial prediction tools are unable to identify a large proportion of patients who will sustain a fracture, whereas many of those with a high fracture risk score will not sustain a fracture. Treatment The evidence for the viability of bone-targeted pharmacotherapy in preventing hip fracture and other clinical fragility fractures is mainly limited to women aged 65–80 years with osteoporosis, whereas the proof of hip fracture-preventing efficacy in women over 80 years of age and in men at all ages is meagre or absent. Further, the antihip fracture efficacy shown in clinical trials is absent in real-life studies. Many drugs for the treatment of osteoporosis have also been associated with increased risks of serious adverse events. There are also considerable uncertainties related to the efficacy of drug therapy in preventing clinical vertebral fractures, whereas the efficacy for preventing other fractures (relative risk reductions of 20–25%) remains moderate, particularly in terms of the low absolute risk reduction in fractures with this treatment. PMID:25809279

  12. [Dynamic magnetotherapy use in comprehensive treatment phlegmons of maxillofacial region and mandible fractures].

    PubMed

    Lepilin, A V; Raĭgorodckiĭ, Iu M; Nozdrachev, V G; Erokina, N L

    2007-01-01

    145 patients (60 with phlegmons of submandibular and submental regions, 85--with fractures of mandible) were observed and treated with the use of moving pulse magnetic field (MPMF) produced by special apparatus (AMO-ATOS-E, , Saratov-city), 60 patients with the same pathology were treated by traditional physical methods and served as control. Use of MPMF led to quicker patient recovery: quicker reduction (if compared with traditional physical methods of treatment) of oedema and soft tissue inflammatory infiltration, quicker relief from inflammatory reaction (according to data of cytokinin profile), improvement of tissue blood supply in the region of fractures in patients with mandible fractures. As the result--we had shortening treatment terms of such patients and complication number reduction.

  13. Studying damage accumulation in martensitic corrosion-resistant steel under cold radial reduction

    NASA Astrophysics Data System (ADS)

    Karamyshev, A. P.; Nekrasov, I. I.; Nesterenko, A. V.; Parshin, V. S.; Smirnov, S. V.; Shveikin, V. P.; Fedulov, A. A.

    2017-12-01

    Cold radial reduction of specimens made of the Kh17N2 corrosion-resistant martensitic steel is studied on a lever-type radial-forging machine (RFM). The mechanical properties of the deformed specimens, the "damage accumulation - strain" relation in the specimens are obtained with the application of hydrostatic and fractographic methods for fractured specimens. The damage of the Kh17N2 corrosion-resistant steel is evaluated as a result of an experimental study considering the data of simulation by a complex finite element model of cold deformation on a lever-type RFM.

  14. Heterotopic ossification of the elbow after closed reduction and retrograde intramedullary nailing for radial neck fracture treated by anconeus interposition.

    PubMed

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2013-12-01

    Heterotopic ossification around the elbow can lead to considerable functional disability. We describe a case of a 42-year-old man who developed heterotopic ossification of his elbow after closed reduction of the elbow dislocation and radial neck fracture and retrograde intramedullary nailing for radial neck fracture. During the follow-up after initial surgery, movements of the elbow were gradually deteriorated and diagnosed as heterotopic ossification of the elbow. Implant removal, radial head excision along with heterotopic mass, and also interposition of the anconeus muscle resulted in improvement of his elbow mobility. At 18 months of follow-up, patient had elbow flexion arc of 15°-110°, 70° of supination, and 50° of pronation without recurrence of heterotopic ossification. The uniqueness of this case lies in the treatment of heterotopic ossification of the elbow to prevent its recurrence, which was developed after retrograde intramedullary nailing for radial neck fracture following closed reduction.

  15. Survivorship of the native hip joint after percutaneous repair of acetabular fractures in the elderly.

    PubMed

    Gary, Joshua L; Lefaivre, Kelly A; Gerold, Frank; Hay, Michael T; Reinert, Charles M; Starr, Adam J

    2011-10-01

    Our purpose was to examine survivorship of the native hip joint in patients ages 60 and over who underwent percutaneous reduction and fixation of acetabular fractures. A retrospective review at a University Level I Trauma Center was performed. Our institutional trauma database was reviewed. Patients aged 60 or older treated with percutaneous reduction and fixation of acetabular fractures between 1994 and 2007 were selected. 79 consecutive patients with 80 fractures were identified. Rate of conversion to total hip arthroplasty were used to construct a Kaplan-Meier curve showing survivorship of the native hip joint after treatment. 75 fractures had adequate clinical follow-up with a mean of 3.9 years (range 0.5-11.9 years). Average blood loss was 69 cc and there were no postoperative infections. 19/75 (25%) were converted to total hip arthroplasty at a mean time of 1.4 years after the index procedure. Survivorship analysis demonstrated a cumulative survival of 65% at 11.9 years of follow-up. There were no conversions to arthroplasty beyond 4.7 years postoperatively. There were no statistically significant associations between conversion to arthroplasty and age, sex, closed vs. limited open reduction, and simple vs. complex fracture pattern. Percutaneous fixation is a viable treatment option for patients age 60 or greater with acetabular fractures. Rates of conversion to total hip arthroplasty are comparable to open treatment methods and if conversion is required, soft tissues are preserved for future surgery. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Low-dose CT of postoperative pelvic fractures: a comparison with radiography.

    PubMed

    Eriksson, Thomas; Berg, Per; Olerud, Claes; Shalabi, Adel; Hänni, Mari

    2018-01-01

    Background Computed tomography (CT) is superior to conventional radiography (CR) for assessing internal fixation of pelvic fractures, but with a higher radiation exposure. Low-dose CT (LDCT) could possibly have a sufficient diagnostic accuracy but with a lower radiation dose. Purpose To compare postoperative diagnostic accuracy of LDCT and CR after open reduction and internal fixation of pelvic fracture. Material and Methods Twenty-one patients were examined with LDCT and CR 0-9 days after surgery. The examinations were reviewed by two musculoskeletal radiologists. Hardware, degree of fracture reduction, image quality, and reviewing time were assessed, and effective radiation dose was calculated. Inter-reader agreement was calculated. Results LDCT was significantly better than CR in determining whether hardware positioning was assessable ( P < 0.001). Acetabular congruence was assessable in all fractured patients with LDCT. In 12 of the 32 assessments with CR of patients with an acetabular fracture, joint congruence was not assessable due to overlapping hardware ( P = 0.001). Image quality was significantly higher for LDCT. Median time to review was 240 s for LDCT compared to 180 s for CR. Effective dose was 0.79 mSv for LDCT compared to 0.32 mSv for CR ( P < 0.001). Conclusion LDCT is more reliable than CR in assessing hardware position and fracture reduction. Joint congruency is sometimes not possible to assess with CR, due to overlapping hardware. The image quality is higher, but also the effective dose, with LDCT than with CR.

  17. Use of resorbable plates and screws in pediatric facial fractures.

    PubMed

    Eppley, Barry L

    2005-03-01

    The use of resorbable plates and screws for fixation of pediatric facial fractures is both well tolerated and effective. It enables realignment and stable positioning of rapidly healing fracture segments while obviating any future issues secondary to long-term metal retention. Forty-four pediatric facial fractures were treated over a 10-year period at our institution using differing techniques of polymeric bone fixation. Twenty-nine mandible fractures in patients under the age of 10 (age range, 6 months to 8 years) were treated. Displaced fractures of the symphysis, parasymphysis, body, and ramus underwent open reduction and either 1.5-mm or 2.0-mm plate and screw fixation in 14 patients. Subcondylar fractures were treated by a short period of maxillomandibular fixation (3 weeks) achieved with suture ligation between resorbable screws placed at the zygoma and symphysis or a circummandibular suture attached to a zygomatic screw. Fifteen patients (age range, 4 to 11 years) with isolated frontal, supraorbital, intraorbital, or orbitozygomatic fractures were treated by open reduction and internal fixation with 1.5-mm resorbable plates, mesh, and screws. No long-term implant-related complications were seen in any of the treated patients. Resorbable polylactic and polyglycolic acid plates and screws can be an effective fixation method for facial fractures in children in the primary and secondary dentition periods.

  18. Maxillofacial fractures among Sudanese children at Khartoum Dental Teaching Hospital.

    PubMed

    Almahdi, Hatim M; Higzi, Mohammed A

    2016-02-23

    Maxillofacial fractures in children are less frequent compared to adults but result in special complications affecting the growth, function and esthetics. The study aimed at assessing the characteristics and the pattern of facial fractures among children seen at Khartoum Teaching Dental Hospital (KTDH). The study included 390 patients presenting with maxillofacial trauma at KTDH during a year period (2010-2011). A total of 390 patients, diagnosed with facial fractures, were seen at KTDH; 14.1% (55) were children below 16 years of age with the mean age of 10 years (SD ± 3.9). The ratio of males to females was 2.2:1. Most fractures were due to road traffic accidents (RTA) 56.4%, followed by daily living activities 21.8% and assault 16.4%. The most prevalent anatomic sites of fractures were mandible 77%; combination fractures i.e. more than one site 32.7% and zygomatic-complex (13.5%). Concomitant injuries were found in 9.1%. Almost half of the patients were managed conservatively 49.1%, closed reduction 34.5% and surgical open reduction 16.4%. The findings of this study indicated that pediatric facial fractures constitute 14.1% of the total number of facial fractures. RTA was the main cause, which should be considered in legislative and preventive strategies.

  19. Which factor is most important for occurrence of cutout complications in patients treated with proximal femoral nail antirotation? Retrospective analysis of 298 patients.

    PubMed

    Turgut, Ali; Kalenderer, Önder; Karapınar, Levent; Kumbaracı, Mert; Akkan, Hasan Ali; Ağuş, Haluk

    2016-05-01

    Mechanical complications, such as cut-out of the head-neck fixation device, are the most common causes of morbidity after trochanteric femur fracture treatment. The causes of cut-out complications are well defined in patients who are treated with sliding hip screws and biaxial cephalomedullary nails but there are few reports about the patients who are treated with proximal femoral nail antirotation. The purpose of this study was to evaluate the most important factor about occurance of cutout complication and also to evaluate the risks of the combination of each possible factors. Overally 298 patients were enrolled in the study. Medical records were reviewed for patients' age, fracture type, gender, anesthesia type and occurance of cut-out complication. Postoperatively taken radiographs were reviewed for tip-apex distance, obtained collo-diaphyseal angle, the quadrant of the helical blade and Ikuta reduction subgroup. The most important factor (s) and also predicted probability of cut-out complication was calculated for each combination of factors. Cut-out complication was observed in 14 patients (4.7 %). The most important factor about occurrence of the cut-out complication was found as varus reduction (p: 0.01), the second important factor was found as implantation of the helical blade in the improper quadrant (p: 0.02). Tip-apex distance was found as third important factor (p: 0.10). The predicted probability of cut-out complication was calculated as 45.6 % when whole of the four surgeon dependent factors were improperly obtained. Althought obtaining proper tip-apex distance is important to prevent cutout complication in these fractures, if the fracture is not reduced in varus position and helical blade is inserted in the proper quadrant, possibility of cut-out complication is very low even in the patients with high tip-apex distance.

  20. Pediatric mandibular fractures: a free hand technique.

    PubMed

    Davison, S P; Clifton, M S; Davison, M N; Hedrick, M; Sotereanos, G

    2001-01-01

    The treatment of pediatric mandibular fractures is rare, controversial, and complicated by mixed dentition. To determine if open mandibular fracture repair with intraoral and extraoral rigid plate placement, after free hand occlusal and bone reduction, without intermaxillary fixation (IMF), is appropriate and to discuss postoperative advantages, namely, maximal early return of function and minimal oral hygiene issues. A group of 29 pediatric patients with a mandibular fracture were examined. Twenty pediatric patients (13 males and 7 females) with a mean age of 9 years (age range, 1-17 years) were treated using IMF. All patients were treated by the same surgeon (G.S.). Surgical time for plating was reduced by 1 hour, the average time to place patients in IMF. The patients who underwent open reduction internal fixation without IMF ate a soft mechanical diet by postoperative day 3 compared with postoperative day 16 for those who underwent IMF. Complication rates related to fixation technique were comparable at 20% for those who did not undergo IMF and 33% for those who did. We believe that free hand reduction is a valuable technique to reduce operative time for pediatric mandibular fractures. It maximizes return to function while minimizing the oral hygiene issues and hardware removal of intermaxillary function.

Top