Sample records for frequency carm driver

  1. MM-wave cyclotron auto-resonance maser for plasma heating

    NASA Astrophysics Data System (ADS)

    Ceccuzzi, S.; Dattoli, G.; Di Palma, E.; Doria, A.; Gallerano, G. P.; Giovenale, E.; Mirizzi, F.; Spassovsky, I.; Ravera, G. L.; Surrenti, V.; Tuccillo, A. A.

    2014-02-01

    Heating and Current Drive systems are of outstanding relevance in fusion plasmas, magnetically confined in tokamak devices, as they provide the tools to reach, sustain and control burning conditions. Heating systems based on the electron cyclotron resonance (ECRH) have been extensively exploited on past and present machines DEMO, and the future reactor will require high frequencies. Therefore, high power (≥1MW) RF sources with output frequency in the 200 - 300 GHz range would be necessary. A promising source is the so called Cyclotron Auto-Resonance Maser (CARM). Preliminary results of the conceptual design of a CARM device for plasma heating, carried out at ENEA-Frascati will be presented together with the planned R&D development.

  2. Insulin-induced CARM1 upregulation facilitates hepatocyte proliferation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeom, Chul-gon; Kim, Dong-il; Park, Min-jung

    Previously, we reported that CARM1 undergoes ubiquitination-dependent degradation in renal podocytes. It was also reported that CARM1 is necessary for fasting-induced hepatic gluconeogenesis. Based on these reports, we hypothesized that treatment with insulin, a hormone typically present under the ‘fed’ condition, would inhibit gluconeogenesis via CARM1 degradation. HepG2 cells, AML-12 cells, and rat primary hepatocytes were treated with insulin to confirm CARM1 downregulation. Surprisingly, insulin treatment increased CARM1 expression in all cell types examined. Furthermore, treatment with insulin increased histone 3 methylation at arginine 17 and 26 in HepG2 cells. To elucidate the role of insulin-induced CARM1 upregulation, the HA-CARM1more » plasmid was transfected into HepG2 cells. CARM1 overexpression did not increase the expression of lipogenic proteins generally increased by insulin signaling. Moreover, CARM1 knockdown did not influence insulin sensitivity. Insulin is known to facilitate hepatic proliferation. Like insulin, CARM1 overexpression increased CDK2 and CDK4 expression. In addition, CARM1 knockdown reduced the number of insulin-induced G2/M phase cells. Moreover, GFP-CARM1 overexpression increased the number of G2/M phase cells. Based on these results, we concluded that insulin-induced CARM1 upregulation facilitates hepatocyte proliferation. These observations indicate that CARM1 plays an important role in liver pathophysiology. - Highlights: • Insulin treatment increases CARM1 expression in hepatocytes. • CARM1 overexpression does not increase the expression of lipogenic proteins. • CARM1 knockdown does not influence insulin sensitivity. • Insulin-induced CARM1 upregulation facilitates hepatocyte proliferation.« less

  3. C-arm rotation encoding with accelerometers.

    PubMed

    Grzeda, Victor; Fichtinger, Gabor

    2010-07-01

    Fluoroscopic C-arms are being incorporated in computer-assisted interventions in increasing number. For these applications to work, the relative poses of imaging must be known. To find the pose, tracking methods such as optical cameras, electromagnetic trackers, and radiographic fiducials have been used-all hampered by significant shortcomings. We propose to recover the rotational pose of the C-arm using the angle-sensing ability of accelerometers, by exploiting the capability of the accelerometer to measure tilt angles. By affixing the accelerometer to a C-arm, the accelerometer tracks the C-arm pose during rotations of the C-arm. To demonstrate this concept, a C-arm analogue was constructed with a webcam device affixed to the C-arm model to mimic X-ray imaging. Then, measuring the offset between the accelerometer angle readings to the webcam pose angle, an angle correction equation (ACE) was created to properly tracking the C-arm rotational pose. Several tests were performed on the webcam C-arm model using the ACEs to tracking the primary and secondary angle rotations of the model. We evaluated the capability of linear and polynomial ACEs to tracking the webcam C-arm pose angle for different rotational scenarios. The test results showed that the accelerometer could track the pose of the webcam C-arm model with an accuracy of less than 1.0 degree. The accelerometer was successful in sensing the C-arm's rotation with clinically adequate accuracy in the C-arm webcam model.

  4. In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging

    PubMed Central

    Ganguly, A.; Fieselmann, A.; Boese, J.; Rohkohl, C.; Hornegger, J.; Fahrig, R.

    2012-01-01

    Purpose: The authors have developed a method to enable cerebral perfusion CT imaging using C-arm based conebeam CT (CBCT). This allows intraprocedural monitoring of brain perfusion during treatment of stroke. Briefly, the technique consists of acquiring multiple scans (each scan comprised of six sweeps) acquired at different time delays with respect to the start of the x-ray contrast agent injection. The projections are then reconstructed into angular blocks and interpolated at desired time points. The authors have previously demonstrated its feasibility in vivo using an animal model. In this paper, the authors describe an in vitro technique to evaluate the accuracy of their method for measuring the relevant temporal signals. Methods: The authors’ evaluation method is based on the concept that any temporal signal can be represented by a Fourier series of weighted sinusoids. A sinusoidal phantom was developed by varying the concentration of iodine as successive steps of a sine wave. Each step corresponding to a different dilution of iodine contrast solution contained in partitions along a cylinder. By translating the phantom along the axis at different velocities, sinusoidal signals at different frequencies were generated. Using their image acquisition and reconstruction algorithm, these sinusoidal signals were imaged with a C-arm system and the 3D volumes were reconstructed. The average value in a slice was plotted as a function of time. The phantom was also imaged using a clinical CT system with 0.5 s rotation. C-arm CBCT results using 6, 3, 2, and 1 scan sequences were compared to those obtained using CT. Data were compared for linear velocities of the phantom ranging from 0.6 to 1 cm/s. This covers the temporal frequencies up to 0.16 Hz corresponding to a frequency range within which 99% of the spectral energy for all temporal signals in cerebral perfusion imaging is contained. Results: The errors in measurement of temporal frequencies are mostly below 2% for all multiscan sequences. For single scan sequences, the errors increase sharply beyond 0.10 Hz. The amplitude errors increase with frequency and with decrease in the number of scans used. Conclusions: Our multiscan perfusion CT approach allows low errors in signal frequency measurement. Increasing the number of scans reduces the amplitude errors. A two-scan sequence appears to offer the best compromise between accuracy and the associated total x-ray and iodine dose. PMID:23127059

  5. Task-Driven Orbit Design and Implementation on a Robotic C-Arm System for Cone-Beam CT.

    PubMed

    Ouadah, S; Jacobson, M; Stayman, J W; Ehtiati, T; Weiss, C; Siewerdsen, J H

    2017-03-01

    This work applies task-driven optimization to the design of non-circular orbits that maximize imaging performance for a particular imaging task. First implementation of task-driven imaging on a clinical robotic C-arm system is demonstrated, and a framework for orbit calculation is described and evaluated. We implemented a task-driven imaging framework to optimize orbit parameters that maximize detectability index d '. This framework utilizes a specified Fourier domain task function and an analytical model for system spatial resolution and noise. Two experiments were conducted to test the framework. First, a simple task was considered consisting of frequencies lying entirely on the f z -axis (e.g., discrimination of structures oriented parallel to the central axial plane), and a "circle + arc" orbit was incorporated into the framework as a means to improve sampling of these frequencies, and thereby increase task-based detectability. The orbit was implemented on a robotic C-arm (Artis Zeego, Siemens Healthcare). A second task considered visualization of a cochlear implant simulated within a head phantom, with spatial frequency response emphasizing high-frequency content in the ( f y , f z ) plane of the cochlea. An optimal orbit was computed using the task-driven framework, and the resulting image was compared to that for a circular orbit. For the f z -axis task, the circle + arc orbit was shown to increase d ' by a factor of 1.20, with an improvement of 0.71 mm in a 3D edge-spread measurement for edges located far from the central plane and a decrease in streak artifacts compared to a circular orbit. For the cochlear implant task, the resulting orbit favored complementary views of high tilt angles in a 360° orbit, and d ' was increased by a factor of 1.83. This work shows that a prospective definition of imaging task can be used to optimize source-detector orbit and improve imaging performance. The method was implemented for execution of non-circular, task-driven orbits on a clinical robotic C-arm system. The framework is sufficiently general to include both acquisition parameters (e.g., orbit, kV, and mA selection) and reconstruction parameters (e.g., a spatially varying regularizer).

  6. Task-driven orbit design and implementation on a robotic C-arm system for cone-beam CT

    NASA Astrophysics Data System (ADS)

    Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.

    2017-03-01

    Purpose: This work applies task-driven optimization to the design of non-circular orbits that maximize imaging performance for a particular imaging task. First implementation of task-driven imaging on a clinical robotic C-arm system is demonstrated, and a framework for orbit calculation is described and evaluated. Methods: We implemented a task-driven imaging framework to optimize orbit parameters that maximize detectability index d'. This framework utilizes a specified Fourier domain task function and an analytical model for system spatial resolution and noise. Two experiments were conducted to test the framework. First, a simple task was considered consisting of frequencies lying entirely on the fz-axis (e.g., discrimination of structures oriented parallel to the central axial plane), and a "circle + arc" orbit was incorporated into the framework as a means to improve sampling of these frequencies, and thereby increase task-based detectability. The orbit was implemented on a robotic C-arm (Artis Zeego, Siemens Healthcare). A second task considered visualization of a cochlear implant simulated within a head phantom, with spatial frequency response emphasizing high-frequency content in the (fy, fz) plane of the cochlea. An optimal orbit was computed using the task-driven framework, and the resulting image was compared to that for a circular orbit. Results: For the fz-axis task, the circle + arc orbit was shown to increase d' by a factor of 1.20, with an improvement of 0.71 mm in a 3D edge-spread measurement for edges located far from the central plane and a decrease in streak artifacts compared to a circular orbit. For the cochlear implant task, the resulting orbit favored complementary views of high tilt angles in a 360° orbit, and d' was increased by a factor of 1.83. Conclusions: This work shows that a prospective definition of imaging task can be used to optimize source-detector orbit and improve imaging performance. The method was implemented for execution of non-circular, task-driven orbits on a clinical robotic C-arm system. The framework is sufficiently general to include both acquisition parameters (e.g., orbit, kV, and mA selection) and reconstruction parameters (e.g., a spatially varying regularizer).

  7. Congenital Anorectal Malformation Severity Does Not Predict Severity of Congenital Heart Defects.

    PubMed

    Jonker, Jara E; Liem, Eryn T; Elzenga, Nynke J; Molenbuur, Bouwe; Trzpis, Monika; Broens, Paul M A

    2016-12-01

    To determine the prevalence of congenital heart defects (CHDs) in patients with mild or severe congenital anorectal malformations (CARMs), and whether all patients with CARM need pediatric cardiology screening. We included 129 patients with CARM born between 2004 and 2013, and referred to University Medical Center Groningen. Recto-perineal and recto-vestibular fistulas were classified as mild CARMs, all others as severe. Significant patent foramen ovale, secundum atrial septal defect, and small ventricular septum defect were classified as minor CHDs, all others as major. Of 129 patients with CARM, 67% had mild CARM, 33% severe CARM, and 17% were additionally diagnosed with CHD. CHDs were distributed equally in patients with mild or severe CARMs. Patients with multiple congenital abnormalities were more frequently diagnosed with CHD (n = 16, 36%) than patients without multiple congenital malformations (n = 5, 9%, P = .001). Patients with CARM diagnosed with CHD using pediatric cardiac echo screening were younger than 3 months of age at diagnosis. Earlier general pediatric examinations missed 7 (50%) children with mild and 4 (50%) with severe CHDs. The severity of CARM could predict neither prevalence nor severity of CHD. More than one-half of CHDs were missed during the first physical examination. No new CHDs were found in patients older than 3 months of age at the time CARMs were diagnosed. We recommend screening all patients with CARM younger than 3 months of age for CHD at the time CARM is diagnosed. Preoperative echocardiography should be the rule in children younger than 3 months of age and with multiple congenital anomalies. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Expression and sub-cellular localization of an epigenetic regulator, co-activator arginine methyltransferase 1 (CARM1), is associated with specific breast cancer subtypes and ethnicity

    PubMed Central

    2013-01-01

    Background Co-Activator Arginine Methyltransferase 1(CARM1) is an Estrogen Receptor (ER) cofactor that remodels chromatin for gene regulation via methylation of Histone3. We investigated CARM1 levels and localization across breast cancer tumors in a cohort of patients of either European or African ancestry. Methods We analyzed CARM1 levels using tissue microarrays with over 800 histological samples from 549 female cancer patients from the US and Nigeria, Africa. We assessed associations between CARM1 expression localized to the nucleus and cytoplasm for 11 distinct variables, including; ER status, Progesterone Receptor status, molecular subtypes, ethnicity, HER2+ status, other clinical variables and survival. Results We found that levels of cytoplasmic CARM1 are distinct among tumor sub-types and increased levels are associated with ER-negative (ER-) status. Higher nuclear CARM1 levels are associated with HER2 receptor status. EGFR expression also correlates with localization of CARM1 into the cytoplasm. This suggests there are distinct functions of CARM1 among molecular tumor types. Our data reveals a basal-like subtype association with CARM1, possibly due to expression of Epidermal Growth Factor Receptor (EGFR). Lastly, increased cytoplasmic CARM1, relative to nuclear levels, appear to be associated with self-identified African ethnicity and this result is being further investigated using quantified genetic ancestry measures. Conclusions Although it is known to be an ER cofactor in breast cancer, CARM1 expression levels are independent of ER. CARM1 has distinct functions among molecular subtypes, as is indicative of its sub-cellular localization and it may function in subtype etiology. These sub-cellular localization patterns, indicate a novel role beyond its ER cofactor function in breast cancer. Differential localization among ethnic groups may be due to ancestry-specific polymorphisms which alter the gene product. PMID:23663560

  9. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    PubMed

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  10. Comparison of C-arm computed tomography and on-site quick cortisol assay for adrenal venous sampling: A retrospective study of 178 patients.

    PubMed

    Chang, Chin-Chen; Lee, Bo-Ching; Chang, Yeun-Chung; Wu, Vin-Cent; Huang, Kuo-How; Liu, Kao-Lang

    2017-12-01

    To compare the performance of on-site quick cortisol assay (QCA) and C-arm computed tomography (CT) assistance on adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. The institutional review board at our hospital approved this retrospective study, which included 178 consecutive patients with primary aldosteronism. During AVS, we used C-arm CT to confirm right adrenal cannulation between May 2012 and June 2015 (n = 100) and QCA for bilateral adrenal cannulation between July 2015 and September 2016 (n = 78). Successful AVS required a selectivity index (cortisol adrenal vein /cortisol peripheral ) of ≥ 2.0 bilaterally. The overall success rate of C-arm CT-assisted AVS was 87%, which increased to 97.4% under QCA (P = .013). The procedure time (C-arm CT, 49.5 ± 21.3 min; QCA, 37.5 ± 15.6 min; P < .001) and radiation dose (C-arm CT, 673.9 ± 613.8 mGy; QCA, 346.4 ± 387.8 mGy; P < .001) were also improved. The resampling rate was 16% and 21.8% for C-arm CT and QCA, respectively. The initial success rate of the performing radiologist remained stable during the study period (C-arm CT 75%; QCA, 82.1%, P = .259). QCA might be superior to C-arm CT for improving the performance of AVS. • Adrenal venous sampling (AVS) is a technically challenging procedure. • C-arm CT and quick cortisol assay (QCA) are efficient for assisting AVS. • QCA might outperform C-arm CT in enhancing AVS performance.

  11. The MEPUC concept adapts the C-arm fluoroscope to image-guided surgery.

    PubMed

    Suhm, Norbert; Müller, Paul; Bopp, Urs; Messmer, Peter; Regazzoni, Pietro

    2004-06-01

    Image-guided surgery requires surgeons to be able to manipulate the imaging modality themselves and without delay. Intraoperative fluoroscopic imaging does not meet this requirement as the C-arm fluoroscope cannot be operated or positioned by the surgeons themselves. The Motorized Exact Positioning Unit for C-arm (MEPUC) concept aims to optimize the workflow of positioning the C-arm fluoroscope. The hardware component of the MEPUC equips the fluoroscope with electric stepping motors. The software component allows the surgeon to control the fluoroscope's movements. The study presented here showed that translational movements within the x-y plane are most frequently performed when positioning the C-arm fluoroscope. Furthermore, reproducing a former projection was found to be a frequent task during image-guided procedures. In our opinion, the MEPUC concept adapts the fluoroscope to image-guided surgery. The most important improvement being definition of a bidirectional data exchange between the surgeon and the C-arm fluoroscope: positioning data from the surgeon to the C-arm fluoroscope and-subsequently-image information from C-arm fluoroscope to the surgeon.

  12. Coactivator-associated arginine methyltransferase 1 enhances transcriptional activity of the human T-cell lymphotropic virus type 1 long terminal repeat through direct interaction with Tax.

    PubMed

    Jeong, Soo-Jin; Lu, Hanxin; Cho, Won-Kyung; Park, Hyeon Ung; Pise-Masison, Cynthia; Brady, John N

    2006-10-01

    In this study, we demonstrate that the coactivator-associated arginine methyltransferase 1 (CARM1), which methylates histone H3 and other proteins such as p300/CBP, is positively involved in the regulation of Tax transactivation. First, transfection studies demonstrated that overexpression of CARM1 wild-type protein resulted in increased Tax transactivation of the human T-cell lymphotropic virus type 1 (HTLV-1) long terminal repeat (LTR). In contrast, transfection of a catalytically inactive CARM1 methyltransferase mutant did not enhance Tax transactivation. CARM1 facilitated Tax transactivation of the CREB-dependent cellular GEM promoter. A direct physical interaction between HTLV-1 Tax and CARM1 was demonstrated using in vitro glutathione S-transferase-Tax binding assays, in vivo coimmunoprecipitation, and confocal microscopy experiments. Finally, chromatin immunoprecipitation analysis of the activated HTLV-1 LTR promoter showed the association of CARM1 and methylated histone H3 with the template DNA. In vitro, Tax facilitates the binding of CARM1 to the transcription complex. Together, our data provide evidence that CARM1 enhances Tax transactivation of the HTLV-1 LTR through a direct interaction between CARM1 and Tax and this binding promotes methylation of histone H3 (R2, R17, and R26).

  13. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    PubMed Central

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor

    2011-01-01

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use. PMID:21992346

  14. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients.

    PubMed

    Kamran, Mudassar; Byrne, James V

    2015-09-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31%) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91% sensitive and 100% specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (≈ 60% blood flow and ≈ 40% blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (≈ 60%) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia.

  15. Intra-operative 3D guidance in prostate brachytherapy using a non-isocentric C-arm.

    PubMed

    Jain, A; Deguet, A; Iordachita, I; Chintalapani, G; Blevins, J; Le, Y; Armour, E; Burdette, C; Song, D; Fichtinger, G

    2007-01-01

    Intra-operative guidance in Transrectal Ultrasound (TRUS) guided prostate brachytherapy requires localization of inserted radioactive seeds relative to the prostate. Seeds were reconstructed using a typical C-arm, and exported to a commercial brachytherapy system for dosimetry analysis. Technical obstacles for 3D reconstruction on a non-isocentric C-arm included pose-dependent C-arm calibration; distortion correction; pose estimation of C-arm images; seed reconstruction; and C-arm to TRUS registration. In precision-machined hard phantoms with 40-100 seeds, we correctly reconstructed 99.8% seeds with a mean 3D accuracy of 0.68 mm. In soft tissue phantoms with 45-87 seeds and clinically realistic 15 degrees C-arm motion, we correctly reconstructed 100% seeds with an accuracy of 1.3 mm. The reconstructed 3D seed positions were then registered to the prostate segmented from TRUS. In a Phase-1 clinical trial, so far on 4 patients with 66-84 seeds, we achieved intra-operative monitoring of seed distribution and dosimetry. We optimized the 100% prescribed iso-dose contour by inserting an average of 3.75 additional seeds, making intra-operative dosimetry possible on a typical C-arm, at negligible additional cost to the existing clinical installation.

  16. Characterization of Vitis vinifera L. Cv. Carménère grape and wine proanthocyanidins.

    PubMed

    Fernández, Katherina; Kennedy, James A; Agosin, Eduardo

    2007-05-02

    A formal compositional study of the proanthocyanidins of Vitis vinifera L. cv. Carménère was conducted in this work. We first characterized the polymeric proanthocyanidins of Carménère skins, seeds, and wines. In addition, the wine astringency was analyzed and compared with Cabernet Sauvignon. Although Carménère wines had a higher proanthocyanidin concentration and mean degree of polymerization than Cabernet Sauvignon wines, the former wines were perceived as less astringent. The low seed/skin proportion in Carménère wines as compared to other varieties, as evidenced by the reduced number of seeds per berry and the higher amount of epigallocatechin subunits of Carménère wine proanthocyanidins, could explain this apparent paradox.

  17. Automatic C-arm pose estimation via 2D/3D hybrid registration of a radiographic fiducial

    NASA Astrophysics Data System (ADS)

    Moult, E.; Burdette, E. C.; Song, D. Y.; Abolmaesumi, P.; Fichtinger, G.; Fallavollita, P.

    2011-03-01

    Motivation: In prostate brachytherapy, real-time dosimetry would be ideal to allow for rapid evaluation of the implant quality intra-operatively. However, such a mechanism requires an imaging system that is both real-time and which provides, via multiple C-arm fluoroscopy images, clear information describing the three-dimensional position of the seeds deposited within the prostate. Thus, accurate tracking of the C-arm poses proves to be of critical importance to the process. Methodology: We compute the pose of the C-arm relative to a stationary radiographic fiducial of known geometry by employing a hybrid registration framework. Firstly, by means of an ellipse segmentation algorithm and a 2D/3D feature based registration, we exploit known FTRAC geometry to recover an initial estimate of the C-arm pose. Using this estimate, we then initialize the intensity-based registration which serves to recover a refined and accurate estimation of the C-arm pose. Results: Ground-truth pose was established for each C-arm image through a published and clinically tested segmentation-based method. Using 169 clinical C-arm images and a +/-10° and +/-10 mm random perturbation of the ground-truth pose, the average rotation and translation errors were 0.68° (std = 0.06°) and 0.64 mm (std = 0.24 mm). Conclusion: Fully automated C-arm pose estimation using a 2D/3D hybrid registration scheme was found to be clinically robust based on human patient data.

  18. Optimising use of the mini C-arm in foot and ankle surgery.

    PubMed

    Gangopadhyay, Soham; Scammell, Brigitte E

    2009-01-01

    The mini C-arm reduces exposure to ionising radiation compared to the conventional C-arm. Optimising radiation exposure is not only desirable, but also a legal requirement and protocols should be in place to achieve this. Since 2004, all elective foot surgery requiring intraoperative imaging was performed using the mini C-arm. Screening times and radiation doses were recorded for each procedure. Following a learning curve, the screening times stabilised around the median value for the individual procedures. For subtalar or triple arthrodesis this was less than 60 s, for ankle arthrodesis, less than 90 s, for hindfoot arthrodesis using a nail, less than 100 s and for joint injections less than 12 s. Screening time can be used as an audit tool to measure optimum use of the mini C-arm. A protocol is presented including an audit form for every operation where the mini C-arm is used. Radiation protection issues are addressed.

  19. Using methylene blue as a marker to find and remove tiny metallic foreign bodies embedded in the soft tissues of children: A randomised controlled trial.

    PubMed

    Su, Yuxi; Nan, Guoxin

    2016-05-01

    Embedment of metallic foreign bodies in the soft tissues is commonly encountered in the emergency room. Most foreign bodies are easily removed, but removal is difficult if the foreign body is very small or deeply embedded. To determine the usefulness of methylene blue staining in the surgical removal of tiny metallic foreign bodies embedded in the soft tissue. This prospective study involved 41 children treated between May 2007 and May 2012. The patients were randomly divided into a methylene blue group and a control group. In the control group, foreign bodies were located using a C-arm and removed via direct incision. In the methylene blue group, foreign bodies were located using a C-arm, marked with an injection of methylene blue and then removed surgically. The clinical outcomes, complications, operation time, surgical success rate, incision length, frequency of C-arm use, and length and depth of the foreign body were compared between the two groups. The surgical success rate was significantly higher in the methylene blue group. The average operation time was significantly shorter in the methylene blue group. The C-arm was used significantly less frequently in the methylene blue group than in the control group. The incision length was significantly shorter in the methylene blue group than in the control group. Methylene blue staining facilitated the location and removal of tiny metallic foreign bodies from the soft tissue, and significantly reduced operation time, incision length and radiation exposure compared to the conventional method. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  20. The Dystrophin Glycoprotein Complex Regulates the Epigenetic Activation of Muscle Stem Cell Commitment.

    PubMed

    Chang, Natasha C; Sincennes, Marie-Claude; Chevalier, Fabien P; Brun, Caroline E; Lacaria, Melanie; Segalés, Jessica; Muñoz-Cánoves, Pura; Ming, Hong; Rudnicki, Michael A

    2018-05-03

    Asymmetrically dividing muscle stem cells in skeletal muscle give rise to committed cells, where the myogenic determination factor Myf5 is transcriptionally activated by Pax7. This activation is dependent on Carm1, which methylates Pax7 on multiple arginine residues, to recruit the ASH2L:MLL1/2:WDR5:RBBP5 histone methyltransferase complex to the proximal promoter of Myf5. Here, we found that Carm1 is a specific substrate of p38γ/MAPK12 and that phosphorylation of Carm1 prevents its nuclear translocation. Basal localization of the p38γ/p-Carm1 complex in muscle stem cells occurs via binding to the dystrophin-glycoprotein complex (DGC) through β1-syntrophin. In dystrophin-deficient muscle stem cells undergoing asymmetric division, p38γ/β1-syntrophin interactions are abrogated, resulting in enhanced Carm1 phosphorylation. The resulting progenitors exhibit reduced Carm1 binding to Pax7, reduced H3K4-methylation of chromatin, and reduced transcription of Myf5 and other Pax7 target genes. Therefore, our experiments suggest that dysregulation of p38γ/Carm1 results in altered epigenetic gene regulation in Duchenne muscular dystrophy. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Contrast-enhanced cardiac C-arm CT evaluation of radiofrequency ablation lesions in the left ventricle

    PubMed Central

    Girard, Erin E; Al-Ahmad, Amin A; Rosenberg, Jarrett; Luong, Richard; Moore, Teri; Lauritsch, Günter; Boese, Jan; Fahrig, Rebecca

    2011-01-01

    Objectives The purpose of this study was to evaluate use of cardiac C-arm computed tomography (CT) in the assessment of the dimensions and temporal characteristics of radiofrequency ablation (RFA) lesions. This imaging modality uses a standard C-arm fluoroscopy system rotating around the patient, providing CT-like images during the RFA procedure. Background Both magnetic resonance imaging (MRI) and CT can be used to assess myocardial necrotic tissue. Several studies have reported visualizing cardiac RF ablation lesions with MRI, however obtaining MR images during interventional procedures is not common practice. Direct visualization of RFA lesions using C-arm CT during the procedure may improve outcomes and circumvent complications associated with cardiac ablation procedures. Methods RFA lesions were created on the endocardial surface of the left ventricle of 9 swine using a 7-F RF ablation catheter. An ECG-gated C-arm CT imaging protocol was used to acquire projection images during iodine contrast injection and following the injection every 5 min for up to 30 min, with no additional contrast. Reconstructed images were analyzed offline. The mean and standard deviation of the signal intensity of the lesion and normal myocardium were measured in all images in each time series. Lesion dimensions and area were measured and compared in pathologic specimens and C-arm CT images. Results All ablation lesions (n=29) were visualized and lesion dimensions, as measured on C-arm CT, correlated well with postmortem tissue measurements (1D dimensions : concordance correlation = 0.87; area : concordance correlation = 0.90). Lesions were visualized as a perfusion defect on first-pass C-arm CT images with a signal intensity 95 HU lower than normal myocardium (95% confidence interval: -111 to -79 HU). Images acquired at 1 and 5 minutes exhibited an enhancing ring surrounding the perfusion defect in 24 (83%) lesions. Conclusions RFA lesion size, including transmurality, can be assessed using ECG-gated cardiac C-arm CT in the interventional suite. Visualization of RFA lesions using cardiac C-arm CT may facilitate the assessment of adequate lesion delivery and provide valuable feedback during cardiac ablation procedures. PMID:21414574

  2. Expression, purification, crystallization and preliminary crystallographic study of isolated modules of the mouse coactivator-associated arginine methyltransferase 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Troffer-Charlier, Nathalie; Cura, Vincent; Hassenboehler, Pierre

    2007-04-01

    Isolated modules of mouse coactivator-associated arginine methyltransferase 1 encompassing the protein arginine N-methyltransferase catalytic domain have been overexpressed, purified and crystallized. X-ray diffraction data have been collected and have enabled determination of the structures by multiple isomorphous replacement using anomalous scattering. Coactivator-associated arginine methyltransferase 1 (CARM1) plays a crucial role in gene expression as a coactivator of several nuclear hormone receptors and also of non-nuclear receptor systems. Its recruitment by the transcriptional machinery induces protein methylation, leading to chromatin remodelling and gene activation. CARM1{sub 28–507} and two structural states of CARM1{sub 140–480} were expressed, purified and crystallized. Crystals of CARM1{submore » 28–507} belong to space group P6{sub 2}22, with unit-cell parameters a = b = 136.0, c = 125.3 Å; they diffract to beyond 2.5 Å resolution using synchrotron radiation and contain one monomer in the asymmetric unit. The structure of CARM1{sub 28–507} was solved by multiple isomorphous replacement and anomalous scattering methods. Crystals of apo CARM1{sub 140–480} belong to space group I222, with unit-cell parameters a = 74.6, b = 99.0, c = 207.4 Å; they diffract to beyond 2.7 Å resolution and contain two monomers in the asymmetric unit. Crystals of CARM1{sub 140–480} in complex with S-adenosyl-l-homocysteine belong to space P2{sub 1}2{sub 1}2, with unit-cell parameters a = 74.6, b = 98.65, c = 206.08 Å; they diffract to beyond 2.6 Å resolution and contain four monomers in the asymmetric unit. The structures of apo and holo CARM1{sub 140–480} were solved by molecular-replacement techniques from the structure of CARM1{sub 28–507}.« less

  3. Reliability and Usefulness of Intraoperative 3-Dimensional Imaging by Mobile C-Arm With Flat-Panel Detector.

    PubMed

    Fujimori, Takahito; Iwasaki, Motoki; Nagamoto, Yukitaka; Kashii, Masafumi; Takao, Masaki; Sugiura, Tsuyoshi; Yoshikawa, Hideki

    2017-02-01

    Reliability and agreement study. To assess the reliability of intraoperative 3-dimensional imaging with a mobile C-arm (3D C-arm) equipped with a flat-panel detector. Pedicle screws are widely used in spinal surgery. Postoperative computed tomography (CT) is the most reliable method to detect screw misplacement. Recent advances in imaging devices have enabled surgeons to acquire 3D images of the spine during surgery. However, the reliability of these imaging devices is not known. A total of 203 screws were used in 22 consecutive patients who underwent surgery for scoliosis. Screw position was read twice with a 3D C-arm and twice with CT in a blinded manner by 2 independent observers. Screw positions were classified into 4 categories at every 2 mm and then into 2 simpler categories of acceptable or unacceptable. The degree of agreement with respect to screw positions between the double readings was evaluated by κ value. With unanimous agreement between 2 observers regarding postoperative CT readings considered the gold standard, the sensitivity of the 3D C-arm for determining screw misplacement was calculated. A total 804 readings were performed. For the 4-category classification, the mean κ value for the 2 interobserver readings was 0.52 for the 3D C-arm and 0.46 for CT. For the 2-category classification, the mean κ value for the 2 interobserver readings was 0.80 for the 3D C-arm and 0.66 for CT. The sensitivity, specificity, positive predictive value, and negative predictive value of intraoperative imaging with the 3D C-arm were 70%, 95%, 44%, and 98%, respectively. With respect to screws with perforation ≥4 mm, the sensitivity was 83%. No revision surgery was performed. Intraoperative imaging with a 3D C-arm was reliable for detecting screw misplacement and helpful in decreasing the rate of revision surgery for screw misplacement.

  4. C-arm positioning using virtual fluoroscopy for image-guided surgery

    NASA Astrophysics Data System (ADS)

    de Silva, T.; Punnoose, J.; Uneri, A.; Goerres, J.; Jacobson, M.; Ketcha, M. D.; Manbachi, A.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.

    2017-03-01

    Introduction: Fluoroscopically guided procedures often involve repeated acquisitions for C-arm positioning at the cost of radiation exposure and time in the operating room. A virtual fluoroscopy system is reported with the potential of reducing dose and time spent in C-arm positioning, utilizing three key advances: robust 3D-2D registration to a preoperative CT; real-time forward projection on GPU; and a motorized mobile C-arm with encoder feedback on C-arm orientation. Method: Geometric calibration of the C-arm was performed offline in two rotational directions (orbit α, orbit β). Patient registration was performed using image-based 3D-2D registration with an initially acquired radiograph of the patient. This approach for patient registration eliminated the requirement for external tracking devices inside the operating room, allowing virtual fluoroscopy using commonly available systems in fluoroscopically guided procedures within standard surgical workflow. Geometric accuracy was evaluated in terms of projection distance error (PDE) in anatomical fiducials. A pilot study was conducted to evaluate the utility of virtual fluoroscopy to aid C-arm positioning in image guided surgery, assessing potential improvements in time, dose, and agreement between the virtual and desired view. Results: The overall geometric accuracy of DRRs in comparison to the actual radiographs at various C-arm positions was PDE (mean ± std) = 1.6 ± 1.1 mm. The conventional approach required on average 8.0 ± 4.5 radiographs spent "fluoro hunting" to obtain the desired view. Positioning accuracy improved from 2.6o ± 2.3o (in α) and 4.1o ± 5.1o (in β) in the conventional approach to 1.5o ± 1.3o and 1.8o ± 1.7o, respectively, with the virtual fluoroscopy approach. Conclusion: Virtual fluoroscopy could improve accuracy of C-arm positioning and save time and radiation dose in the operating room. Such a system could be valuable to training of fluoroscopy technicians as well as intraoperative use in fluoroscopically guided procedures.

  5. Limited angle C-arm tomosynthesis reconstruction algorithms

    NASA Astrophysics Data System (ADS)

    Malalla, Nuhad A. Y.; Xu, Shiyu; Chen, Ying

    2015-03-01

    In this paper, C-arm tomosynthesis with digital detector was investigated as a novel three dimensional (3D) imaging technique. Digital tomosythses is an imaging technique to provide 3D information of the object by reconstructing slices passing through the object, based on a series of angular projection views with respect to the object. C-arm tomosynthesis provides two dimensional (2D) X-ray projection images with rotation (-/+20 angular range) of both X-ray source and detector. In this paper, four representative reconstruction algorithms including point by point back projection (BP), filtered back projection (FBP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were investigated. Dataset of 25 projection views of 3D spherical object that located at center of C-arm imaging space was simulated from 25 angular locations over a total view angle of 40 degrees. With reconstructed images, 3D mesh plot and 2D line profile of normalized pixel intensities on focus reconstruction plane crossing the center of the object were studied with each reconstruction algorithm. Results demonstrated the capability to generate 3D information from limited angle C-arm tomosynthesis. Since C-arm tomosynthesis is relatively compact, portable and can avoid moving patients, it has been investigated for different clinical applications ranging from tumor surgery to interventional radiology. It is very important to evaluate C-arm tomosynthesis for valuable applications.

  6. virtX - evaluation of a computer-based training system for mobile C-arm systems in trauma and orthopedic surgery.

    PubMed

    Bott, O J; Teistler, M; Duwenkamp, C; Wagner, M; Marschollek, M; Plischke, M; Raab, B W; Stürmer, K M; Pretschner, D P; Dresing, K

    2008-01-01

    Operating room personnel (ORP) operating mobile image intensifier systems (C-arms) need training to produce high quality radiographs with a minimum of time and X-ray exposure. Our study aims at evaluating acceptance, usability and learning effect of the CBT system virtX that simulates C-arm based X-ray imaging in the context of surgical case scenarios. Prospective, interventional study conducted during an ORP course with three groups: intervention group 1 (training on a PC using virtX), and 2 (virtX with a C-arm as input device), and a control group (training without virtX) - IV1, IV2 and CG. All participants finished training with the same exercise. Time needed to produce an image of sufficient quality was recorded and analyzed using One-Way-ANOVA and Dunnett post hoc test (alpha = .05). Acceptance and usability of virtX have been evaluated using a questionnaire. CG members (n = 21) needed more time for the exercise than those of IV2 (n = 20): 133 +/- 55 vs. 101 +/- 37 sec. (p = .03). IV1 (n = 12) also performed better than CG (128 +/- 48 sec.), but this was not statistically significant. Seventy-nine participants returned a questionnaire (81% female, age 34 +/- 9 years, professional experience 8.3 +/- 7.6 years; 77% regularly used a C-arm). 83% considered virtX a useful addition to conventional C-arm training. 91% assessed virtual radiography as helpful for understanding C-arm operation. Trainees experienced virtX as substantial enhancement of C-arm training. Training with virtX can reduce the time needed to perform an imaging task.

  7. 2D–3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery

    PubMed Central

    Liu, Wen Pei; Otake, Yoshito; Azizian, Mahdi; Wagner, Oliver J.; Sorger, Jonathan M.; Armand, Mehran; Taylor, Russell H.

    2015-01-01

    Purpose C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D–3D registration is needed for intra-procedural guidance. C-arm radiographs were registered to CBCT scans and used for 3D localization of peritumor fiducials during a minimally invasive thoracic intervention with a da Vinci Si robot. Methods Intensity-based 2D–3D registration of intraoperative radiographs to CBCT was performed. The feasible range of X-ray projections achievable by a C-arm positioned around a da Vinci Si surgical robot, configured for robotic wedge resection, was determined using phantom models. Experiments were conducted on synthetic phantoms and animals imaged with an OEC 9600 and a Siemens Artis zeego, representing the spectrum of different C-arm systems currently available for clinical use. Results The image guidance workflow was feasible using either an optically tracked OEC 9600 or a Siemens Artis zeego C-arm, resulting in an angular difference of Δθ : ~ 30°. The two C-arm systems provided TREmean ≤ 2.5 mm and TREmean ≤ 2.0 mm, respectively (i.e., comparable to standard clinical intraoperative navigation systems). Conclusions C-arm 3D localization from dual 2D–3D registered radiographs was feasible and applicable for intraoperative image guidance during da Vinci robotic thoracic interventions using the proposed workflow. Tissue deformation and in vivo experiments are required before clinical evaluation of this system. PMID:25503592

  8. A method of percutaneous vertebroplasty under the guidance of two C-arm fluoroscopes

    PubMed Central

    Xu, Ren-Jie; Yan, Yong-Qing; Chen, Guang-Xiang; Zou, Tian-Ming; Cai, Xiao-Qiang; Wang, Dong-Lai

    2014-01-01

    Objective: To compare the clinical application in the percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. Methods: One hundred forty three elderly patients with Osteoporotic vertebral compression fractures (OVCFs) underwent percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. The number of pulsed imagings, the time of operation and the incidence of cement leakage were recorded. Results: The average number of pulsed imagings was 16.00±1.58 vs 13.07±2.00 per patient under the guidance of one vs two C-arm fluoroscopes. The average time of operation was 48.42±5.00 minutes vs 39.70±7.42 minutes per patient under the guidance of one vs two C-arm fluoroscopes. The incidence of cement leakage was 20% vs 15.7% of the patients under the guidance of one vs two C-arm fluoroscopes. The differences in the number of pulsed imagings and the time of operation were statistically significant. The difference in incidence of cement leakage was not statistically significant. Conclusion: The two-fluoroscopic technique reduce the labor cost, the radiation, the time of operation and the operation risk. PMID:24772138

  9. Marker detection evaluation by phantom and cadaver experiments for C-arm pose estimation pattern

    NASA Astrophysics Data System (ADS)

    Steger, Teena; Hoßbach, Martin; Wesarg, Stefan

    2013-03-01

    C-arm fluoroscopy is used for guidance during several clinical exams, e.g. in bronchoscopy to locate the bronchoscope inside the airways. Unfortunately, these images provide only 2D information. However, if the C-arm pose is known, it can be used to overlay the intrainterventional fluoroscopy images with 3D visualizations of airways, acquired from preinterventional CT images. Thus, the physician's view is enhanced and localization of the instrument at the correct position inside the bronchial tree is facilitated. We present a novel method for C-arm pose estimation introducing a marker-based pattern, which is placed on the patient table. The steel markers form a pattern, allowing to deduce the C-arm pose by use of the projective invariant cross-ratio. Simulations show that the C-arm pose estimation is reliable and accurate for translations inside an imaging area of 30 cm x 50 cm and rotations up to 30°. Mean error values are 0.33 mm in 3D space and 0.48 px in the 2D imaging plane. First tests on C-arm images resulted in similarly compelling accuracy values and high reliability in an imaging area of 30 cm x 42.5 cm. Even in the presence of interfering structures, tested both with anatomy phantoms and a turkey cadaver, high success rates over 90% and fully satisfying execution times below 4 sec for 1024 px × 1024 px images could be achieved.

  10. Reduced-dose C-arm computed tomography applications at a pediatric institution.

    PubMed

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie

    2017-12-01

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.

  11. Planning Evaluation of C-Arm Cone Beam CT Angiography for Target Delineation in Stereotactic Radiation Surgery of Brain Arteriovenous Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Jun; Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland; Huang, Judy

    Purpose: Stereotactic radiation surgery (SRS) is one of the therapeutic modalities currently available to treat cerebral arteriovenous malformations (AVM). Conventionally, magnetic resonance imaging (MRI) and MR angiography (MRA) and digital subtraction angiography (DSA) are used in combination to identify the target volume for SRS treatment. The purpose of this study was to evaluate the use of C-arm cone beam computed tomography (CBCT) in the treatment planning of SRS for cerebral AVMs. Methods and Materials: Sixteen consecutive patients treated for brain AVMs at our institution were included in this retrospective study. Prior to treatment, all patients underwent MRA, DSA, and C-arm CBCT.more » All images were coregistered using the GammaPlan planning system. AVM regions were delineated independently by 2 physicians using either C-arm CBCT or MRA, resulting in 2 volumes: a CBCT volume (VCBCT) and an MRA volume (V{sub MRA}). SRS plans were generated based on the delineated regions. Results: The average volume of treatment targets delineated using C-arm CBCT and MRA were similar, 6.40 cm{sup 3} and 6.98 cm{sup 3}, respectively (P=.82). However, significant regions of nonoverlap existed. On average, the overlap of the MRA with the C-arm CBCT was only 52.8% of the total volume. In most cases, radiation plans based on V{sub MRA} did not provide adequate dose to the region identified on C-arm CBCT; the mean minimum dose to V{sub CBCT} was 29.5%, whereas the intended goal was 45% (P<.001). The mean volume of normal brain receiving 12 Gy or more in C-arm CBCT-based plans was not greater than in the MRA-based plans. Conclusions: Use of C-arm CBCT images significantly alters the delineated regions of AVMs for SRS planning, compared to that of MRA/MRI images. CT-based planning can be accomplished without increasing the dose to normal brain and may represent a more accurate definition of the nidus, increasing the chances for successful obliteration.« less

  12. How Does Patient Radiation Exposure Compare With Low-dose O-arm Versus Fluoroscopy for Pedicle Screw Placement in Idiopathic Scoliosis?

    PubMed

    Su, Alvin W; McIntosh, Amy L; Schueler, Beth A; Milbrandt, Todd A; Winkler, Jennifer A; Stans, Anthony A; Larson, A Noelle

    Intraoperative C-arm fluoroscopy and low-dose O-arm are both reasonable means to assist in screw placement for idiopathic scoliosis surgery. Both using pediatric low-dose O-arm settings and minimizing the number of radiographs during C-arm fluoroscopy guidance decrease patient radiation exposure and its deleterious biological effect that may be associated with cancer risk. We hypothesized that the radiation dose for C-arm-guided fluoroscopy is no less than low-dose O-arm scanning for placement of pedicle screws. A multicenter matched-control cohort study of 28 patients in total was conducted. Fourteen patients who underwent O-arm-guided pedicle screw insertion for spinal fusion surgery in 1 institution were matched to another 14 patients who underwent C-arm fluoroscopy guidance in the other institution in terms of the age of surgery, body weight, and number of imaged spine levels. The total effective dose was compared. A low-dose pediatric protocol was used for all O-arm scans with an effective dose of 0.65 mSv per scan. The effective dose of C-arm fluoroscopy was determined using anthropomorphic phantoms that represented the thoracic and lumbar spine in anteroposterior and lateral views, respectively. The clinical outcome and complications of all patients were documented. The mean total effective dose for the O-arm group was approximately 4 times higher than that of the C-arm group (P<0.0001). The effective dose for the C-arm patients had high variability based on fluoroscopy time and did not correlate with the number of imaged spine levels or body weight. The effective dose of 1 low-dose pediatric O-arm scan approximated 85 seconds of the C-arm fluoroscopy time. All patients had satisfactory clinical outcomes without major complications that required returning to the operating room. Radiation exposure required for O-arm scans can be higher than that required for C-arm fluoroscopy, but it depends on fluoroscopy time. Inclusion of more medical centers and surgeons will better account for the variability of C-arm dose due to distinct patient characteristics, surgeon's preference, and individual institution's protocol. Level III-case-control study.

  13. Polyphenols of Carménère Grapes

    PubMed Central

    Huamán-Castilla, Nils Leander; Mariotti-Celis, María Salomé; Pérez-Correa, José Ricardo

    2017-01-01

    Carménère is the emblematic grape of Chile. Recent studies indicate that it has a different polyphenolic profile than other commercial varieties of grape among other factors, due to its long maturation period. The grape and wine of Carménère stand out for having high concentrations of anthocyanins (malvidin), flavonols (quercetin and myricetin) and flavanols (catechin, epicatechin and epigallocatechin). These compounds are related to the distinctive characteristic of Carménère wine regarding astringency and color. In vivo and in vitro models suggest some positive effects of these polyphenols in the treatment and prevention of chronic diseases, such as atherosclerosis and cancer. Therefore, there is a high level of interest to develop scalable industrial methods in order to obtain and purify Carménère grape polyphenol extracts that could be used to improve the characteristics of wines from other varieties or produce nutraceuticals or functional foods for preventing and treating various chronic diseases. PMID:28845147

  14. C-arm technique using distance driven method for nephrolithiasis and kidney stones detection

    NASA Astrophysics Data System (ADS)

    Malalla, Nuhad; Sun, Pengfei; Chen, Ying; Lipkin, Michael E.; Preminger, Glenn M.; Qin, Jun

    2016-04-01

    Distance driven represents a state of art method that used for reconstruction for x-ray techniques. C-arm tomography is an x-ray imaging technique that provides three dimensional information of the object by moving the C-shaped gantry around the patient. With limited view angle, C-arm system was investigated to generate volumetric data of the object with low radiation dosage and examination time. This paper is a new simulation study with two reconstruction methods based on distance driven including: simultaneous algebraic reconstruction technique (SART) and Maximum Likelihood expectation maximization (MLEM). Distance driven is an efficient method that has low computation cost and free artifacts compared with other methods such as ray driven and pixel driven methods. Projection images of spherical objects were simulated with a virtual C-arm system with a total view angle of 40 degrees. Results show the ability of limited angle C-arm technique to generate three dimensional images with distance driven reconstruction.

  15. Intraoperative positioning of mobile C-arms using artificial fluoroscopy

    NASA Astrophysics Data System (ADS)

    Dressel, Philipp; Wang, Lejing; Kutter, Oliver; Traub, Joerg; Heining, Sandro-Michael; Navab, Nassir

    2010-02-01

    In trauma and orthopedic surgery, imaging through X-ray fluoroscopy with C-arms is ubiquitous. This leads to an increase in ionizing radiation applied to patient and clinical staff. Placing these devices in the desired position to visualize a region of interest is a challenging task, requiring both skill of the operator and numerous X-rays for guidance. We propose an extension to C-arms for which position data is available that provides the surgeon with so called artificial fluoroscopy. This is achieved by computing digitally reconstructed radiographs (DRRs) from pre- or intraoperative CT data. The approach is based on C-arm motion estimation, for which we employ a Camera Augmented Mobile C-arm (CAMC) system, and a rigid registration of the patient to the CT data. Using this information we are able to generate DRRs and simulate fluoroscopic images. For positioning tasks, this system appears almost exactly like conventional fluoroscopy, however simulating the images from the CT data in realtime as the C-arm is moved without the application of ionizing radiation. Furthermore, preoperative planning can be done on the CT data and then visualized during positioning, e.g. defining drilling axes for pedicle approach techniques. Since our method does not require external tracking it is suitable for deployment in clinical environments and day-to-day routine. An experiment with six drillings into a lumbar spine phantom showed reproducible accuracy in positioning the C-arm, ranging from 1.1 mm to 4.1 mm deviation of marker points on the phantom compared in real and virtual images.

  16. The activity and stability of the transcriptional coactivator p/CIP/SRC-3 are regulated by CARM1-dependent methylation.

    PubMed

    Naeem, Hina; Cheng, Donghang; Zhao, Qingshi; Underhill, Caroline; Tini, Marc; Bedford, Marc T; Torchia, Joseph

    2007-01-01

    The transcriptional coactivator p/CIP(SRC-3/AIB1/ACTR/RAC3) binds liganded nuclear hormone receptors and facilitates transcription by directly recruiting accessory factors such as acetyltransferase CBP/p300 and the coactivator arginine methyltransferase CARM1. In the present study, we have established that recombinant p/CIP (p300/CBP interacting protein) is robustly methylated by CARM1 in vitro but not by other protein arginine methyltransferase family members. Metabolic labeling of MCF-7 breast cancer cells with S-adenosyl-L-[methyl-(3)H]methionine and immunoblotting using dimethyl arginine-specific antibodies demonstrated that p/CIP is specifically methylated in intact cells. In addition, methylation of full-length p/CIP is not supported by extracts derived from CARM1(-/-) mouse embryo fibroblasts, indicating that CARM1 is required for p/CIP methylation. Using mass spectrometry, we have identified three CARM1-dependent methylation sites located in a glutamine-rich region within the carboxy terminus of p/CIP which are conserved among all steroid receptor coactivator proteins. These results were confirmed by in vitro methylation of p/CIP using carboxy-terminal truncation mutants and synthetic peptides as substrates for CARM1. Analysis of methylation site mutants revealed that arginine methylation causes an increase in full-length p/CIP turnover as a result of enhanced degradation. Additionally, methylation negatively impacts transcription via a second mechanism by impairing the ability of p/CIP to associate with CBP. Collectively, our data highlight coactivator methylation as an important regulatory mechanism in hormonal signaling.

  17. Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite.

    PubMed

    Yang, Pengfei; Niu, Kai; Wu, Yijing; Struffert, Tobias; Dorfler, Arnd; Schafer, Sebastian; Royalty, Kevin; Strother, Charles; Chen, Guang-Hong

    2015-12-01

    Multimodal imaging using cone beam C-arm computed tomography (CT) may shorten the delay from ictus to revascularization for acute ischemic stroke patients with a large vessel occlusion. Largely because of limited temporal resolution, reconstruction of time-resolved CT angiography (CTA) from these systems has not yielded satisfactory results. We evaluated the image quality and diagnostic value of time-resolved C-arm CTA reconstructed using novel image processing algorithms. Studies were done under an Institutional Review Board approved protocol. Postprocessing of data from 21 C-arm CT dynamic perfusion acquisitions from 17 patients with acute ischemic stroke were done to derive time-resolved C-arm CTA images. Two observers independently evaluated image quality and diagnostic content for each case. ICC and receiver-operating characteristic analysis were performed to evaluate interobserver agreement and diagnostic value of this novel imaging modality. Time-resolved C-arm CTA images were successfully generated from 20 data sets (95.2%, 20/21). Two observers agreed well that the image quality for large cerebral arteries was good but was more limited for small cerebral arteries (distal to M1, A1, and P1). receiver-operating characteristic curves demonstrated excellent diagnostic value for detecting large vessel occlusions (area under the curve=0.987-1). Time-resolved CTAs derived from C-arm CT perfusion acquisitions provide high quality images that allowed accurate diagnosis of large vessel occlusions. Although image quality of smaller arteries in this study was not optimal ongoing modifications of the postprocessing algorithm will likely remove this limitation. Adding time-resolved C-arm CTAs to the capabilities of the angiography suite further enhances its suitability as a one-stop shop for care for patients with acute ischemic stroke. © 2015 American Heart Association, Inc.

  18. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation.

    PubMed

    Ritschl, Ludwig; Kuntz, Jan; Fleischmann, Christof; Kachelrieß, Marc

    2016-05-01

    In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled data set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. The method proposed here employs 3D imaging using C-arms with less than 180° rotation range adding full 3D functionality to a C-arm device retaining both handling comfort and the usability of 2D imaging. This method has a clear potential for clinical use especially to meet the increasing demand for an intraoperative 3D imaging.

  19. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritschl, Ludwig; Fleischmann, Christof; Kuntz, Jan, E-mail: j.kuntz@dkfz.de

    Purpose: In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled datamore » set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. Methods: The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. Results: The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. Conclusions: The method proposed here employs 3D imaging using C-arms with less than 180° rotation range adding full 3D functionality to a C-arm device retaining both handling comfort and the usability of 2D imaging. This method has a clear potential for clinical use especially to meet the increasing demand for an intraoperative 3D imaging.« less

  20. Contrast-Enhanced C-arm Computed Tomography Imaging of Myocardial Infarction in the Interventional Suite

    PubMed Central

    Girard, Erin E; Al-Ahmad, Amin; Rosenberg, Jarrett; Luong, Richard; Moore, Teri; Lauritsch, Günter; Chan, Frandics; Lee, David P.; Fahrig, Rebecca

    2014-01-01

    Objectives Cardiac C-arm CT uses a standard C-arm fluoroscopy system rotating around the patient to provide CT-like images during interventional procedures without moving the patient to a conventional CT scanner. We hypothesize that C-arm computed tomography (CT) can be used to visualize and quantify the size of perfusion defects and late enhancement resulting from a myocardial infarction (MI) using contrast enhanced techniques similar to previous CT and magnetic resonance imaging studies. Materials and Methods A balloon occlusion followed by reperfusion in a coronary artery was used to study acute and subacute MI in 12 swine. ECG-gated C-arm CT images were acquired the day of infarct creation (n=6) or 4 weeks after infarct creation (n = 6). Images were acquired immediately following contrast injection, then at 1 minute, and every 5 minutes up to 30 minutes with no additional contrast. The volume of the infarct as measured on C-arm CT was compared against pathology. Results The volume of acute MI, visualized as a combined region of hyperenhancement with a hypoenhanced core, correlated well with pathologic staining (concordance correlation = 0.89, p<0.0001, mean difference = 0.67±2.98 cm3). The volume of subacute MI, visualized as a region of hyperenhancement, correlated well with pathologic staining at imaging times 5–15 minutes following contrast injection (concordance correlation = 0.82, p<.001, mean difference = −0.64±1.94 cm3). Conclusions C-arm CT visualization of acute and subacute myocardial infarction is possible in a porcine model but improvement in the imaging technique is important before clinical use. Visualization of MI in the catheterization lab may be possible and could provide 3D images for guidance during interventional procedures. PMID:25635589

  1. Informatics in radiology: use of a C-arm fluoroscopy simulator to support training in intraoperative radiography.

    PubMed

    Bott, Oliver Johannes; Dresing, Klaus; Wagner, Markus; Raab, Björn-Werner; Teistler, Michael

    2011-01-01

    Mobile image intensifier systems (C-arms) are used frequently in orthopedic and reconstructive surgery, especially in trauma and emergency settings, but image quality and radiation exposure levels may vary widely, depending on the extent of the C-arm operator's knowledge and experience. Current training programs consist mainly of theoretical instruction in C-arm operation, the physical foundations of radiography, and radiation avoidance, and are largely lacking in hands-on application. A computer-based simulation program such as that tested by the authors may be one way to improve the effectiveness of C-arm training. In computer simulations of various scenarios commonly encountered in the operating room, trainees using the virtX program interact with three-dimensional models to test their knowledge base and improve their skill levels. Radiographs showing the simulated patient anatomy and surgical implants are "reconstructed" from data computed on the basis of the trainee's positioning of models of a C-arm, patient, and table, and are displayed in real time on the desktop monitor. Trainee performance is signaled in real time by color graphics in several control panels and, on completion of the exercise, is compared in detail with the performance of an expert operator. Testing of this computer-based training program in continuing medical education courses for operating room personnel showed an improvement in the overall understanding of underlying principles of intraoperative radiography performed with a C-arm, with resultant higher image quality, lower overall radiation exposure, and greater time efficiency. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.313105125/-/DC1. Copyright © RSNA, 2011.

  2. Tracker-on-C for cone-beam CT-guided surgery: evaluation of geometric accuracy and clinical applications

    NASA Astrophysics Data System (ADS)

    Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.

    2012-02-01

    Conventional surgical tracking configurations carry a variety of limitations in line-of-sight, geometric accuracy, and mismatch with the surgeon's perspective (for video augmentation). With increasing utilization of mobile C-arms, particularly those allowing cone-beam CT (CBCT), there is opportunity to better integrate surgical trackers at bedside to address such limitations. This paper describes a tracker configuration in which the tracker is mounted directly on the Carm. To maintain registration within a dynamic coordinate system, a reference marker visible across the full C-arm rotation is implemented, and the "Tracker-on-C" configuration is shown to provide improved target registration error (TRE) over a conventional in-room setup - (0.9+/-0.4) mm vs (1.9+/-0.7) mm, respectively. The system also can generate digitally reconstructed radiographs (DRRs) from the perspective of a tracked tool ("x-ray flashlight"), the tracker, or the C-arm ("virtual fluoroscopy"), with geometric accuracy in virtual fluoroscopy of (0.4+/-0.2) mm. Using a video-based tracker, planning data and DRRs can be superimposed on the video scene from a natural perspective over the surgical field, with geometric accuracy (0.8+/-0.3) pixels for planning data overlay and (0.6+/-0.4) pixels for DRR overlay across all C-arm angles. The field-of-view of fluoroscopy or CBCT can also be overlaid on real-time video ("Virtual Field Light") to assist C-arm positioning. The fixed transformation between the x-ray image and tracker facilitated quick, accurate intraoperative registration. The workflow and precision associated with a variety of realistic surgical tasks were significantly improved using the Tracker-on-C - for example, nearly a factor of 2 reduction in time required for C-arm positioning, reduction or elimination of dose in "hunting" for a specific fluoroscopic view, and confident placement of the x-ray FOV on the surgical target. The proposed configuration streamlines the integration of C-arm CBCT with realtime tracking and demonstrated utility in a spectrum of image-guided interventions (e.g., spine surgery) benefiting from improved accuracy, enhanced visualization, and reduced radiation exposure.

  3. β-Estradiol-dependent activation of the JAK/STAT pathway requires p/CIP and CARM1.

    PubMed

    Coughlan, N; Thillainadesan, G; Andrews, J; Isovic, M; Torchia, J

    2013-06-01

    The steroid receptor coactivator p/CIP, also known as SRC-3, is an oncogene commonly amplified in breast and ovarian cancers. p/CIP is known to associate with coactivator arginine methyltransferase 1 (CARM1) on select estrogen responsive genes. We have shown, using a ChIP-on-chip approach, that in response to stimulation with 17β-estradiol (E2), the p/CIP/CARM1 complex is recruited to 204 proximal promoters in MCF-7 cells. Many of the complex target genes have been previously implicated in signaling pathways related to oncogenesis. Jak2, a member of the Jak/Stat signaling cascade, is one of the direct E2-dependent targets of the p/CIP/CARM1 complex. Following E2-treatment, histone modifications at the Jak2 promoter are reflective of a transcriptionally permissive gene, and modest changes in RNA and protein expression lead us to suggest that an additional factor(s) may be required for a more notable transcriptional and functional response. Bioinformatic examination of the 204 proximal promoter sequences of p/CIP/CARM1 targets supports the idea that transcription factor crosstalk is likely the favored mechanism of E2-dependent p/CIP/CARM1 complex recruitment. This data may have implications towards understanding the oncogenic role of p/CIP in breast cancer and ultimately allow for the identification of new prognostic indicators and/or viable therapeutic targets. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  4. CT imaging with a mobile C-arm prototype

    NASA Astrophysics Data System (ADS)

    Cheryauka, Arvi; Tubbs, David; Langille, Vinton; Kalya, Prabhanjana; Smith, Brady; Cherone, Rocco

    2008-03-01

    Mobile X-ray imagery is an omnipresent tool in conventional musculoskeletal and soft tissue applications. The next generation of mobile C-arm systems can provide clinicians of minimally-invasive surgery and pain management procedures with both real-time high-resolution fluoroscopy and intra-operative CT imaging modalities. In this study, we research two C-arm CT experimental system configurations and evaluate their imaging capabilities. In a non-destructive evaluation configuration, the X-ray Tube - Detector assembly is stationary while an imaging object is placed on a rotating table. In a medical imaging configuration, the C-arm gantry moves around the patient and the table. In our research setting, we connect the participating devices through a Mobile X-Ray Imaging Environment known as MOXIE. MOXIE is a set of software applications for internal research at GE Healthcare - Surgery and used to examine imaging performance of experimental systems. Anthropomorphic phantom volume renderings and orthogonal slices of reconstructed images are obtained and displayed. The experimental C-arm CT results show CT-like image quality that may be suitable for interventional procedures, real-time data management, and, therefore, have great potential for effective use on the clinical floor.

  5. [Transcription of protein arginine N-methyltransferase genes in mouse dorsal root ganglia following peripheral nerve injury].

    PubMed

    Xu, Hua-Li; Xu, Shi-Yuan; Mo, Kai

    2017-12-20

    To investigate the changes in the transcription of protein arginine methylation enzyme family genes in the dorsal root ganglia (DRG) following peripheral nerve injury in mice. C57BL6 mouse models of neuropathic pain induced by peripheral nerve injury were established by bilateral L4 spinal nerve ligation (SNL). At 7 days after SNL or sham operation, the DRG tissue was collected for transcriptional analysis of 9 protein arginine methylation enzyme genes (Prmt1?3, Carm1, and Prmt5?9) using RNA?Seq to identify the differentially expressed genes in the injured DRGs. We also established mouse models of lateral L4 SNL and models of chronic constriction injury (CCI) of the sciatic nerve and tested the paw withdrawal frequency (PWF) in response to mechanical stimulation and paw withdrawal latency (PWL) in response to thermal stimulation on 0, 3, 7 and 14 days after SNL or CCI; the expressions of the differentially expressed genes in the injured DRGs were verified in the two models using RT?qPCR. Among the 9 protein arginine methylation enzyme family genes that were tissue?specifically expressed in the DRG, Prmt2 and Prmt3 showed the highest and Prmt6 showed the lowest basal expression. Compared with the sham?operated mice group, the mice receiving SNL exhibited upregulated Carm1 gene transcription (by 1.7 folds) but downregulated Prmt5, Prmt8 and Prmt9 transcription in the injured DRG (Prmt8 gene showed the most significant down?regulation by 16.3 folds). In mouse models of SNL and CCI, Carm1 gene expression increased progressively with time while Prmt8 transcription was obviously lowered on days 3, 7 and 14 after the injury; the transcription levels of Prmt1, Prmt5 and Prmt9 presented with no significant changes following the injuries. Both SNL and CCI induced mechanical allodynia and thermal hypersensitivities in the mice shown by increased PWF and decreased PWL on days 3, 7 and 14 after the injuries. Periphery nerve injury induces Carm1 upregulation and Prmt8 downregulation in the injured DRG in mice, which sheds light on new targets for treatment of neuropathic pain.

  6. O-arm with navigation versus C-arm: a review of screw placement over 3 years at a major trauma center.

    PubMed

    Verma, S K; Singh, P K; Agrawal, D; Sinha, S; Gupta, D; Satyarthee, G D; Sharma, B S

    2016-12-01

    There is a relatively high incidence of screw misplacement during spinal instrumentation due to distortion of normal anatomy following spinal trauma. The O-arm is the next-generation spinal navigation tool that provides intraoperative 3-D imaging and navigation for spine surgeries. To evaluate and compare the use of O-arm as compared to C-arm for spinal trauma in a Level I trauma center in India. In this retrospective study over 3 years (July 2010-April 2013), All patients of spinal injury who underwent spinal instrumentation were divided into O-arm group and C-arm group. Accuracy of screw placement was assessed during each surgery in both groups. A total of 587 patients were evaluated during the study period. There were 278 patients in O-arm group and 309 patients in C-arm group. Both groups were well matched in mean age (27.7 vs. 28.9 years), ASIA grades, and level of injury. The number of screws placed was significantly higher in the C-arm group as compared to the O-arm group (2173 vs. 1720). However, the O-arm group had significantly less screw malplacement rate of 0.93% (n = 16) as compared to malplacement rate in C-arm group of 8.79% (n = 191, p < 0.05). Use of O-arm imaging system ensures accurate screw placement and dramatically decreases screw malplacement rate, thus providing better patient safety. Its use is especially beneficial in academic and teaching centers where novice surgeons can attain results equivalent to that of experts in spinal instrumentation.

  7. Intra-operative adjustment of standard planes in C-arm CT image data.

    PubMed

    Brehler, Michael; Görres, Joseph; Franke, Jochen; Barth, Karl; Vetter, Sven Y; Grützner, Paul A; Meinzer, Hans-Peter; Wolf, Ivo; Nabers, Diana

    2016-03-01

    With the help of an intra-operative mobile C-arm CT, medical interventions can be verified and corrected, avoiding the need for a post-operative CT and a second intervention. An exact adjustment of standard plane positions is necessary for the best possible assessment of the anatomical regions of interest but the mobility of the C-arm causes the need for a time-consuming manual adjustment. In this article, we present an automatic plane adjustment at the example of calcaneal fractures. We developed two feature detection methods (2D and pseudo-3D) based on SURF key points and also transferred the SURF approach to 3D. Combined with an atlas-based registration, our algorithm adjusts the standard planes of the calcaneal C-arm images automatically. The robustness of the algorithms is evaluated using a clinical data set. Additionally, we tested the algorithm's performance for two registration approaches, two resolutions of C-arm images and two methods for metal artifact reduction. For the feature extraction, the novel 3D-SURF approach performs best. As expected, a higher resolution ([Formula: see text] voxel) leads also to more robust feature points and is therefore slightly better than the [Formula: see text] voxel images (standard setting of device). Our comparison of two different artifact reduction methods and the complete removal of metal in the images shows that our approach is highly robust against artifacts and the number and position of metal implants. By introducing our fast algorithmic processing pipeline, we developed the first steps for a fully automatic assistance system for the assessment of C-arm CT images.

  8. The rotate-plus-shift C-arm trajectory: complete CT data with limited angular rotation

    NASA Astrophysics Data System (ADS)

    Ritschl, Ludwig; Kuntz, Jan; Kachelrieß, Marc

    2015-03-01

    In the last decade C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm scan is performed using a circle-like trajectory around a region of interest. Therefor an angular range of at least 180° plus fan-angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C-arm system, for example a larger C radius or a smaller C opening respectively. These technical modifications are usually not beneficial in terms of handling and usability of the C-arm during classical 2D applications like fluoroscopy. The method proposed in this paper relaxes the constraint of 180° plus fan-angle rotation to acquire a complete data set. The proposed C-arm trajectory requires a motorization of the orbital axis of the C and of ideally two orthogonal axis in the C plane. The trajectory consists of three parts: A rotation of the C around a defined iso-center and two translational movements parallel to the detector plane at the begin and at the end of the rotation. Combining these three parts to one trajectory enables for the acquisition of a completely sampled dataset using only 180° minus fan-angle of rotation. To evaluate the method we show animal and cadaver scans acquired with a mobile C-arm prototype. We expect that the transition of this method into clinical routine will lead to a much broader use of intraoperative 3D imaging in a wide field of clinical applications.

  9. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    PubMed

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1/3 border of the vertebral body was measured, and 75% when distance from target to needle tip was measured. There were no major complications. Minor complications consisted of 3 cases (25%) of cement extravasation. C-arm CBCT with needle path overlay for fluoroscopic guided vertebroplasty is feasible and allows for reliable unilateral therapy of both lumbar and thoracic vertebral bodies. Extrapedicular approaches were performed safely and with good accuracy of reaching the targets.

  10. Automatic cable artifact removal for cardiac C-arm CT imaging

    NASA Astrophysics Data System (ADS)

    Haase, C.; Schäfer, D.; Kim, M.; Chen, S. J.; Carroll, J.; Eshuis, P.; Dössel, O.; Grass, M.

    2014-03-01

    Cardiac C-arm computed tomography (CT) imaging using interventional C-arm systems can be applied in various areas of interventional cardiology ranging from structural heart disease and electrophysiology interventions to valve procedures in hybrid operating rooms. In contrast to conventional CT systems, the reconstruction field of view (FOV) of C-arm systems is limited to a region of interest in cone-beam (along the patient axis) and fan-beam (in the transaxial plane) direction. Hence, highly X-ray opaque objects (e.g. cables from the interventional setup) outside the reconstruction field of view, yield streak artifacts in the reconstruction volume. To decrease the impact of these streaks a cable tracking approach on the 2D projection sequences with subsequent interpolation is applied. The proposed approach uses the fact that the projected position of objects outside the reconstruction volume depends strongly on the projection perspective. By tracking candidate points over multiple projections only objects outside the reconstruction volume are segmented in the projections. The method is quantitatively evaluated based on 30 simulated CT data sets. The 3D root mean square deviation to a reference image could be reduced for all cases by an average of 50 % (min 16 %, max 76 %). Image quality improvement is shown for clinical whole heart data sets acquired on an interventional C-arm system.

  11. Precise X-ray and video overlay for augmented reality fluoroscopy.

    PubMed

    Chen, Xin; Wang, Lejing; Fallavollita, Pascal; Navab, Nassir

    2013-01-01

    The camera-augmented mobile C-arm (CamC) augments any mobile C-arm by a video camera and mirror construction and provides a co-registration of X-ray with video images. The accurate overlay between these images is crucial to high-quality surgical outcomes. In this work, we propose a practical solution that improves the overlay accuracy for any C-arm orientation by: (i) improving the existing CamC calibration, (ii) removing distortion effects, and (iii) accounting for the mechanical sagging of the C-arm gantry due to gravity. A planar phantom is constructed and placed at different distances to the image intensifier in order to obtain the optimal homography that co-registers X-ray and video with a minimum error. To alleviate distortion, both X-ray calibration based on equidistant grid model and Zhang's camera calibration method are implemented for distortion correction. Lastly, the virtual detector plane (VDP) method is adapted and integrated to reduce errors due to the mechanical sagging of the C-arm gantry. The overlay errors are 0.38±0.06 mm when not correcting for distortion, 0.27±0.06 mm when applying Zhang's camera calibration, and 0.27±0.05 mm when applying X-ray calibration. Lastly, when taking into account all angular and orbital rotations of the C-arm, as well as correcting for distortion, the overlay errors are 0.53±0.24 mm using VDP and 1.67±1.25 mm excluding VDP. The augmented reality fluoroscope achieves an accurate video and X-ray overlay when applying the optimal homography calculated from distortion correction using X-ray calibration together with the VDP.

  12. Non-invasive assessment of vasospasm following aneurysmal SAH using C-arm FDCT parenchymal blood volume measurement in the neuro-interventional suite: Technical feasibility

    PubMed Central

    Downer, Jonathan; Corkill, Rufus; Byrne, James V

    2015-01-01

    Introduction Cerebral vasospasm is the leading cause of morbidity and mortality in patients with aneurysmal subarachnoid haemorrhage (SAH) surviving the initial ictus. Commonly used techniques for vasospasm assessment are digital subtraction angiography and transcranial Doppler sonography. These techniques can reliably identify only the major vessel spasm and fail to estimate its haemodynamic significance. To overcome these issues and to enable comprehensive non-invasive assessment of vasospasm inside the interventional suite, a novel protocol involving measurement of parenchymal blood volume (PBV) using C-arm flat detector computed tomography (FDCT) was implemented. Materials and methods Patients from the neuro-intensive treatment unit (ITU) with suspected vasospasm following aneurysmal SAH were scanned with a biplane C-arm angiography system using an intravenous contrast injection protocol. The PBV maps were generated using prototype software. Contemporaneous clinically indicated MR scan including the diffusion- and perfusion-weighted sequences was performed. C-arm PBV maps were compared against the MR perfusion maps. Results Distribution of haemodynamic impairment on C-arm PBV maps closely matched the pattern of abnormality on MR perfusion maps. On visual comparison between the two techniques, the extent of abnormality indicated PBV to be both cerebral blood flow and cerebral blood volume weighted. Conclusion C-arm FDCT PBV measurements allow an objective assessment of the severity and localisation of cerebral hypoperfusion resulting from vasospasm. The technique has proved feasible and useful in very sick patients after aneurysmal SAH. The promise shown in this early study indicates that it deserves further evaluation both for post-SAH vasospasm and in other relevant clinical settings. PMID:26017197

  13. Time density curve analysis for C-arm FDCT PBV imaging.

    PubMed

    Kamran, Mudassar; Byrne, James V

    2016-04-01

    Parenchymal blood volume (PBV) estimation using C-arm flat detector computed tomography (FDCT) assumes a steady-state contrast concentration in cerebral vasculature for the scan duration. Using time density curve (TDC) analysis, we explored if the steady-state assumption is met for C-arm CT PBV scans, and how consistent the contrast-material dynamics in cerebral vasculature are across patients. Thirty C-arm FDCT datasets of 26 patients with aneurysmal-SAH, acquired as part of a prospective study comparing C-arm CT PBV with MR-PWI, were analysed. TDCs were extracted from the 2D rotational projections. Goodness-of-fit of TDCs to a steady-state horizontal-line-model and the statistical similarity among the individual TDCs were tested. Influence of the differences in TDC characteristics on the agreement of resulting PBV measurements with MR-CBV was calculated. Despite identical scan parameters and contrast-injection-protocol, the individual TDCs were statistically non-identical (p < 0.01). Using Dunn's multiple comparisons test, of the total 435 individual comparisons among the 30 TDCs, 330 comparisons (62%) reached statistical significance for difference. All TDCs deviated significantly (p < 0.01) from the steady-state horizontal-line-model. PBV values of those datasets for which the TDCs showed largest deviations from the steady-state model demonstrated poor agreement and correlation with MR-CBV, compared with the PBV values of those datasets for which the TDCs were closer to steady-state. For clinical C-arm CT PBV examinations, the administered contrast material does not reach the assumed 'ideal steady-state' for the duration of scan. Using a prolonged injection protocol, the degree to which the TDCs approximate the ideal steady-state influences the agreement of resulting PBV measurements with MR-CBV. © The Author(s) 2016.

  14. Time density curve analysis for C-arm FDCT PBV imaging

    PubMed Central

    Byrne, James V

    2016-01-01

    Introduction Parenchymal blood volume (PBV) estimation using C-arm flat detector computed tomography (FDCT) assumes a steady-state contrast concentration in cerebral vasculature for the scan duration. Using time density curve (TDC) analysis, we explored if the steady-state assumption is met for C-arm CT PBV scans, and how consistent the contrast-material dynamics in cerebral vasculature are across patients. Methods Thirty C-arm FDCT datasets of 26 patients with aneurysmal-SAH, acquired as part of a prospective study comparing C-arm CT PBV with MR-PWI, were analysed. TDCs were extracted from the 2D rotational projections. Goodness-of-fit of TDCs to a steady-state horizontal-line-model and the statistical similarity among the individual TDCs were tested. Influence of the differences in TDC characteristics on the agreement of resulting PBV measurements with MR-CBV was calculated. Results Despite identical scan parameters and contrast-injection-protocol, the individual TDCs were statistically non-identical (p < 0.01). Using Dunn's multiple comparisons test, of the total 435 individual comparisons among the 30 TDCs, 330 comparisons (62%) reached statistical significance for difference. All TDCs deviated significantly (p < 0.01) from the steady-state horizontal-line-model. PBV values of those datasets for which the TDCs showed largest deviations from the steady-state model demonstrated poor agreement and correlation with MR-CBV, compared with the PBV values of those datasets for which the TDCs were closer to steady-state. Conclusion For clinical C-arm CT PBV examinations, the administered contrast material does not reach the assumed ‘ideal steady-state’ for the duration of scan. Using a prolonged injection protocol, the degree to which the TDCs approximate the ideal steady-state influences the agreement of resulting PBV measurements with MR-CBV. PMID:26769736

  15. Non-invasive assessment of vasospasm following aneurysmal SAH using C-arm FDCT parenchymal blood volume measurement in the neuro-interventional suite: Technical feasibility.

    PubMed

    Kamran, Mudassar; Downer, Jonathan; Corkill, Rufus; Byrne, James V

    2015-08-01

    Cerebral vasospasm is the leading cause of morbidity and mortality in patients with aneurysmal subarachnoid haemorrhage (SAH) surviving the initial ictus. Commonly used techniques for vasospasm assessment are digital subtraction angiography and transcranial Doppler sonography. These techniques can reliably identify only the major vessel spasm and fail to estimate its haemodynamic significance. To overcome these issues and to enable comprehensive non-invasive assessment of vasospasm inside the interventional suite, a novel protocol involving measurement of parenchymal blood volume (PBV) using C-arm flat detector computed tomography (FDCT) was implemented. Patients from the neuro-intensive treatment unit (ITU) with suspected vasospasm following aneurysmal SAH were scanned with a biplane C-arm angiography system using an intravenous contrast injection protocol. The PBV maps were generated using prototype software. Contemporaneous clinically indicated MR scan including the diffusion- and perfusion-weighted sequences was performed. C-arm PBV maps were compared against the MR perfusion maps. Distribution of haemodynamic impairment on C-arm PBV maps closely matched the pattern of abnormality on MR perfusion maps. On visual comparison between the two techniques, the extent of abnormality indicated PBV to be both cerebral blood flow and cerebral blood volume weighted. C-arm FDCT PBV measurements allow an objective assessment of the severity and localisation of cerebral hypoperfusion resulting from vasospasm. The technique has proved feasible and useful in very sick patients after aneurysmal SAH. The promise shown in this early study indicates that it deserves further evaluation both for post-SAH vasospasm and in other relevant clinical settings. © The Author(s) 2015.

  16. Single-camera visual odometry to track a surgical X-ray C-arm base.

    PubMed

    Esfandiari, Hooman; Lichti, Derek; Anglin, Carolyn

    2017-12-01

    This study provides a framework for a single-camera odometry system for localizing a surgical C-arm base. An application-specific monocular visual odometry system (a downward-looking consumer-grade camera rigidly attached to the C-arm base) is proposed in this research. The cumulative dead-reckoning estimation of the base is extracted based on frame-to-frame homography estimation. Optical-flow results are utilized to feed the odometry. Online positional and orientation parameters are then reported. Positional accuracy of better than 2% (of the total traveled distance) for most of the cases and 4% for all the cases studied and angular accuracy of better than 2% (of absolute cumulative changes in orientation) were achieved with this method. This study provides a robust and accurate tracking framework that not only can be integrated with the current C-arm joint-tracking system (i.e. TC-arm) but also is capable of being employed for similar applications in other fields (e.g. robotics).

  17. Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm

    PubMed Central

    Jain, A.; Deguet, A.; Iordachita, I.; Chintalapani, G.; Vikal, S.; Blevins, J.; Le, Y.; Armour, E.; Burdette, C.; Song, D.; Fichtinger, G.

    2015-01-01

    Purpose Brachytherapy (radioactive seed insertion) has emerged as one of the most effective treatment options for patients with prostate cancer, with the added benefit of a convenient outpatient procedure. The main limitation in contemporary brachytherapy is faulty seed placement, predominantly due to the presence of intra-operative edema (tissue expansion). Though currently not available, the capability to intra-operatively monitor the seed distribution, can make a significant improvement in cancer control. We present such a system here. Methods Intra-operative measurement of edema in prostate brachytherapy requires localization of inserted radioactive seeds relative to the prostate. Seeds were reconstructed using a typical non-isocentric C-arm, and exported to a commercial brachytherapy treatment planning system. Technical obstacles for 3D reconstruction on a non-isocentric C-arm include pose-dependent C-arm calibration; distortion correction; pose estimation of C-arm images; seed reconstruction; and C-arm to TRUS registration. Results In precision-machined hard phantoms with 40–100 seeds and soft tissue phantoms with 45–87 seeds, we correctly reconstructed the seed implant shape with an average 3D precision of 0.35 mm and 0.24 mm, respectively. In a DoD Phase-1 clinical trial on six patients with 48–82 planned seeds, we achieved intra-operative monitoring of seed distribution and dosimetry, correcting for dose inhomogeneities by inserting an average of over four additional seeds in the six enrolled patients (minimum 1; maximum 9). Additionally, in each patient, the system automatically detected intra-operative seed migration induced due to edema (mean 3.84 mm, STD 2.13 mm, Max 16.19 mm). Conclusions The proposed system is the first of a kind that makes intra-operative detection of edema (and subsequent re-optimization) possible on any typical non-isocentric C-arm, at negligible additional cost to the existing clinical installation. It achieves a significantly more homogeneous seed distribution, and has the potential to affect a paradigm shift in clinical practice. Large scale studies and commercialization are currently underway. PMID:21168357

  18. Online geometrical calibration of a mobile C-arm using external sensors

    NASA Astrophysics Data System (ADS)

    Mitschke, Matthias M.; Navab, Nassir; Schuetz, Oliver

    2000-04-01

    3D tomographic reconstruction of high contrast objects such as contrast agent enhanced blood vessels or bones from x-ray images acquired by isocentric C-arm systems recently gained interest. For tomographic reconstruction, a sequence of images is captured during the C-arm rotation around the patient and the precise projection geometry has to be determined for each image. This is a difficult task, as C- arms usually do not provide accurate information about their projection geometry. Standard methods propose the use of an x-ray calibration phantom and an offline calibration, when the motion of the C-arm is supposed to be reproducible between calibration and patient run. However, mobile C-arms usually do not have this desirable property. Therefore, an online recovery of projection geometry is necessary. Here, we study the use of external tracking systems such as Polaris or Optotrak from Northern Digital, Inc., for online calibration. In order to use the external tracking system for recovery of x-ray projection geometry two unknown transformations have to be estimated. We describe our attempt to solve this calibration problem. These are the relations between x-ray imaging system and marker plate of the tracking system as well as worked and sensor coordinate system. Experimental result son anatomical data are presented and visually compared with the results of estimating the projection geometry with an x-ray calibration phantom.

  19. Towards clinical translation of augmented orthopedic surgery: from pre-op CT to intra-op x-ray via RGBD sensing

    NASA Astrophysics Data System (ADS)

    Tucker, Emerson; Fotouhi, Javad; Unberath, Mathias; Lee, Sing Chun; Fuerst, Bernhard; Johnson, Alex; Armand, Mehran; Osgood, Greg M.; Navab, Nassir

    2018-03-01

    Pre-operative CT data is available for several orthopedic and trauma interventions, and is mainly used to identify injuries and plan the surgical procedure. In this work we propose an intuitive augmented reality environment allowing visualization of pre-operative data during the intervention, with an overlay of the optical information from the surgical site. The pre-operative CT volume is first registered to the patient by acquiring a single C-arm X-ray image and using 3D/2D intensity-based registration. Next, we use an RGBD sensor on the C-arm to fuse the optical information of the surgical site with patient pre-operative medical data and provide an augmented reality environment. The 3D/2D registration of the pre- and intra-operative data allows us to maintain a correct visualization each time the C-arm is repositioned or the patient moves. An overall mean target registration error (mTRE) and standard deviation of 5.24 +/- 3.09 mm was measured averaged over 19 C-arm poses. The proposed solution enables the surgeon to visualize pre-operative data overlaid with information from the surgical site (e.g. surgeon's hands, surgical tools, etc.) for any C-arm pose, and negates issues of line-of-sight and long setup times, which are present in commercially available systems.

  20. Structural and Functional Impacts of ER Coactivator Sequential Recruitment.

    PubMed

    Yi, Ping; Wang, Zhao; Feng, Qin; Chou, Chao-Kai; Pintilie, Grigore D; Shen, Hong; Foulds, Charles E; Fan, Guizhen; Serysheva, Irina; Ludtke, Steven J; Schmid, Michael F; Hung, Mien-Chie; Chiu, Wah; O'Malley, Bert W

    2017-09-07

    Nuclear receptors recruit multiple coactivators sequentially to activate transcription. This "ordered" recruitment allows different coactivator activities to engage the nuclear receptor complex at different steps of transcription. Estrogen receptor (ER) recruits steroid receptor coactivator-3 (SRC-3) primary coactivator and secondary coactivators, p300/CBP and CARM1. CARM1 recruitment lags behind the binding of SRC-3 and p300 to ER. Combining cryo-electron microscopy (cryo-EM) structure analysis and biochemical approaches, we demonstrate that there is a close crosstalk between early- and late-recruited coactivators. The sequential recruitment of CARM1 not only adds a protein arginine methyltransferase activity to the ER-coactivator complex, it also alters the structural organization of the pre-existing ERE/ERα/SRC-3/p300 complex. It induces a p300 conformational change and significantly increases p300 HAT activity on histone H3K18 residues, which, in turn, promotes CARM1 methylation activity on H3R17 residues to enhance transcriptional activity. This study reveals a structural role for a coactivator sequential recruitment and biochemical process in ER-mediated transcription. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nose, Takayuki, E-mail: nose-takayuki@nms.ac.jp; Chatani, Masashi; Otani, Yuki

    Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images aremore » degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.« less

  2. Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope.

    PubMed

    Nose, Takayuki; Chatani, Masashi; Otani, Yuki; Teshima, Teruki; Kumita, Shinichirou

    2017-03-15

    High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

    PubMed

    Amiri, Shahram; Wilson, David R; Masri, Bassam A; Anglin, Carolyn

    2014-07-01

    C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequate calibration and registration techniques. The solution suggested in this work is a tracked C-arm (TC-arm) which employs a low-cost sensor tracking module that can be retrofitted to any conventional C-arm for tracking the individual joints of the device. Registration and offline calibration methods were developed that allow accurate tracking of the gantry and determination of the exact intrinsic and extrinsic parameters of the imaging system for any acquired fluoroscopic image. The performance of the system was evaluated in comparison to an Optotrak[Formula: see text] motion tracking system and by a series of experiments on accurately built ball-bearing phantoms. Accuracies of the system were determined for 2D-3D registration, three-dimensional landmark localization, and for generating panoramic stitched views in simulated intraoperative applications. The system was able to track the center point of the gantry with an accuracy of [Formula: see text] mm or better. Accuracies of 2D-3D registrations were [Formula: see text] mm and [Formula: see text]. Three-dimensional landmark localization had an accuracy of [Formula: see text] of the length (or [Formula: see text] mm) on average, depending on whether the landmarks were located along, above, or across the table. The overall accuracies of the two-dimensional measurements conducted on stitched panoramic images of the femur and lumbar spine were 2.5 [Formula: see text] 2.0 % [Formula: see text] and [Formula: see text], respectively. The TC-arm system has the potential to achieve sophisticated quantitative fluoroscopy assessment capabilities using an existing C-arm imaging system. This technology may be useful to improve the quality of orthopedic surgery and interventional radiology.

  4. Disruption of histone modification and CARM1 recruitment by arsenic represses transcription at glucocorticoid receptor-regulated promoters.

    PubMed

    Barr, Fiona D; Krohmer, Lori J; Hamilton, Joshua W; Sheldon, Lynn A

    2009-08-26

    Chronic exposure to inorganic arsenic (iAs) found in the environment is one of the most significant and widespread environmental health risks in the U.S. and throughout the world. It is associated with a broad range of health effects from cancer to diabetes as well as reproductive and developmental anomalies. This diversity of diseases can also result from disruption of metabolic and other cellular processes regulated by steroid hormone receptors via aberrant transcriptional regulation. Significantly, exposure to iAs inhibits steroid hormone-mediated gene activation. iAs exposure is associated with disease, but is also used therapeutically to treat specific cancers complicating an understanding of iAs action. Transcriptional activation by steroid hormone receptors is accompanied by changes in histone and non-histone protein post-translational modification (PTM) that result from the enzymatic activity of coactivator and corepressor proteins such as GRIP1 and CARM1. This study addresses how iAs represses steroid receptor-regulated gene transcription. PTMs on histones H3 and H4 at the glucocorticoid receptor (GR)-activated mouse mammary tumor virus (MMTV) promoter were identified by chromatin immunoprecipitation analysis following exposure to steroid hormone+/-iAs. Histone H3K18 and H3R17 amino acid residues had significantly different patterns of PTMs after treatment with iAs. Promoter interaction of the coactivator CARM1 was disrupted, but the interaction of GRIP1, a p160 coactivator through which CARM1 interacts with a promoter, was intact. Over-expression of CARM1 was able to fully restore and GRIP1 partially restored iAs-repressed transcription indicating that these coactivators are functionally associated with iAs-mediated transcriptional repression. Both are essential for robust transcription at steroid hormone regulated genes and both are associated with disease when inappropriately expressed. We postulate that iAs effects on CARM1 and GRIP1 may underlie some of its therapeutic effects and as well be associated with its toxic effects.

  5. The effect of facial makeup on the frequency of drivers stopping for hitchhikers.

    PubMed

    Guéguen, Nicolas; Lamy, Lubomir

    2013-08-01

    Judgments of photographs have shown that makeup enhances ratings of women's facial attractiveness. The present study assessed whether makeup affects the stopping behavior of drivers in response to a hitchhiker's signal. Four 20- to 22-year-old female confederates wore facial makeup, or not, while pretending to be hitchhiking. Frequency of stopping was compared in 1,600 male and female drivers. Facial makeup was associated with an increase in the number of male drivers who stopped to offer a ride. Makeup did not affect frequency of stopping by female drivers.

  6. Motion and positional error correction for cone beam 3D-reconstruction with mobile C-arms.

    PubMed

    Bodensteiner, C; Darolti, C; Schumacher, H; Matthäus, L; Schweikard, A

    2007-01-01

    CT-images acquired by mobile C-arm devices can contain artefacts caused by positioning errors. We propose a data driven method based on iterative 3D-reconstruction and 2D/3D-registration to correct projection data inconsistencies. With a 2D/3D-registration algorithm, transformations are computed to align the acquired projection images to a previously reconstructed volume. In an iterative procedure, the reconstruction algorithm uses the results of the registration step. This algorithm also reduces small motion artefacts within 3D-reconstructions. Experiments with simulated projections from real patient data show the feasibility of the proposed method. In addition, experiments with real projection data acquired with an experimental robotised C-arm device have been performed with promising results.

  7. Percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma under C-arm cone beam CT guidance.

    PubMed

    Amouyal, G; Pernot, S; Déan, C; Cholley, B; Scotté, F; Sapoval, M; Pellerin, O

    2017-11-01

    The aim of this study was to assess the feasibility, safety and efficacy of percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma using C-arm cone beam computed tomography (CBCT) guidance. This single-center prospective observational study was performed from August 2013 to August 2016, and included consecutive patients referred for radiofrequency ablation of lung metastases from colorectal cancer. Radiofrequency ablation procedures were performed under C-arm CBCT guidance. Feasibility was assessed by probe accuracy placement, time to accurate placement and number of C-arm CBCT acquisitions to reach the target lesion. Safety was assessed by the report of adverse event graded using the common terminology criteria for adverse events (CTCAE-V4.0). Efficacy was assessed by metastases response rate using RECIST 1.1 and 18 FDG-PET-CT tumor uptake at 6months. Fifty-four consecutive patients (32 men, 22 women) with a mean age of 63±8 (SD) years (range: 51-81years) with a total of 56 lung metastasis from colorectal metastases were treated in a single session. The mean tumor diameter was 25.6±4.5 (SD)mm (range: 17-31mm). Median time to insert the needle into the target lesion was 10min (range: 5-25min). Median number of needles repositioning and C-arm CBCT acquisition per patient was 1 (range: 0-3) and 4 (range: 3-6) respectively. The accuracy for radiofrequency ablation probe placement was 2±0.2 (SD)mm (range: 0-9mm). Pneumothorax requiring chest tube placement occurred in one patient (CTCAE-V4.0 grade 3). At 6months, all patients were alive with tumor response rate of -27% and had no significant activity on the 18 FDG-PET CT follow-up. Percutaneous radiofrequency ablation of lung metastases from colorectal cancer under C-arm CBCT guidance is feasible and safe, with immediate and short-term results similar to those obtained using conventional CT guidance. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  8. Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langet, Hélène; Laboratoire des Signaux et Systèmes, CentraleSupélec, Gif-sur-Yvette F-91192; Center for Visual Computing, CentraleSupélec, Châtenay-Malabry F-92295

    2015-09-15

    Purpose: This paper addresses the reconstruction of x-ray cone-beam computed tomography (CBCT) for interventional C-arm systems. Subsampling of CBCT is a significant issue with C-arms due to their slow rotation and to the low frame rate of their flat panel x-ray detectors. The aim of this work is to propose a novel method able to handle the subsampling artifacts generally observed with analytical reconstruction, through a content-driven hierarchical reconstruction based on compressed sensing. Methods: The central idea is to proceed with a hierarchical method where the most salient features (high intensities or gradients) are reconstructed first to reduce the artifactsmore » these features induce. These artifacts are addressed first because their presence contaminates less salient features. Several hierarchical schemes aiming at streak artifacts reduction are introduced for C-arm CBCT: the empirical orthogonal matching pursuit approach with the ℓ{sub 0} pseudonorm for reconstructing sparse vessels; a convex variant using homotopy with the ℓ{sub 1}-norm constraint of compressed sensing, for reconstructing sparse vessels over a nonsparse background; homotopy with total variation (TV); and a novel empirical extension to nonlinear diffusion (NLD). Such principles are implemented with penalized iterative filtered backprojection algorithms. For soft-tissue imaging, the authors compare the use of TV and NLD filters as sparsity constraints, both optimized with the alternating direction method of multipliers, using a threshold for TV and a nonlinear weighting for NLD. Results: The authors show on simulated data that their approach provides fast convergence to good approximations of the solution of the TV-constrained minimization problem introduced by the compressed sensing theory. Using C-arm CBCT clinical data, the authors show that both TV and NLD can deliver improved image quality by reducing streaks. Conclusions: A flexible compressed-sensing-based algorithmic approach is proposed that is able to accommodate for a wide range of constraints. It is successfully applied to C-arm CBCT images that may not be so well approximated by piecewise constant functions.« less

  9. Optimization-Based Image Reconstruction with Artifact Reduction in C-Arm CBCT

    PubMed Central

    Xia, Dan; Langan, David A.; Solomon, Stephen B.; Zhang, Zheng; Chen, Buxin; Lai, Hao; Sidky, Emil Y.; Pan, Xiaochuan

    2016-01-01

    We investigate an optimization-based reconstruction, with an emphasis on image-artifact reduction, from data collected in C-arm cone-beam computed tomography (CBCT) employed in image-guided interventional procedures. In the study, an image to be reconstructed is formulated as a solution to a convex optimization program in which a weighted data divergence is minimized subject to a constraint on the image total variation (TV); a data-derivative fidelity is introduced in the program specifically for effectively suppressing dominant, low-frequency data artifact caused by, e.g., data truncation; and the Chambolle-Pock (CP) algorithm is tailored to reconstruct an image through solving the program. Like any other reconstructions, the optimization-based reconstruction considered depends upon numerous parameters. We elucidate the parameters, illustrate their determination, and demonstrate their impact on the reconstruction. The optimization-based reconstruction, when applied to data collected from swine and patient subjects, yields images with visibly reduced artifacts in contrast to the reference reconstruction, and it also appears to exhibit a high degree of robustness against distinctively different anatomies of imaged subjects and scanning conditions of clinical significance. Knowledge and insights gained in the study may be exploited for aiding in the design of practical reconstructions of truly clinical-application utility. PMID:27694700

  10. Optimization-based image reconstruction with artifact reduction in C-arm CBCT

    NASA Astrophysics Data System (ADS)

    Xia, Dan; Langan, David A.; Solomon, Stephen B.; Zhang, Zheng; Chen, Buxin; Lai, Hao; Sidky, Emil Y.; Pan, Xiaochuan

    2016-10-01

    We investigate an optimization-based reconstruction, with an emphasis on image-artifact reduction, from data collected in C-arm cone-beam computed tomography (CBCT) employed in image-guided interventional procedures. In the study, an image to be reconstructed is formulated as a solution to a convex optimization program in which a weighted data divergence is minimized subject to a constraint on the image total variation (TV); a data-derivative fidelity is introduced in the program specifically for effectively suppressing dominant, low-frequency data artifact caused by, e.g. data truncation; and the Chambolle-Pock (CP) algorithm is tailored to reconstruct an image through solving the program. Like any other reconstructions, the optimization-based reconstruction considered depends upon numerous parameters. We elucidate the parameters, illustrate their determination, and demonstrate their impact on the reconstruction. The optimization-based reconstruction, when applied to data collected from swine and patient subjects, yields images with visibly reduced artifacts in contrast to the reference reconstruction, and it also appears to exhibit a high degree of robustness against distinctively different anatomies of imaged subjects and scanning conditions of clinical significance. Knowledge and insights gained in the study may be exploited for aiding in the design of practical reconstructions of truly clinical-application utility.

  11. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?

    PubMed

    Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit

    2017-07-01

    Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Intraoperative imaging for patient safety and QA: detection of intracranial hemorrhage using C-arm cone-beam CT

    NASA Astrophysics Data System (ADS)

    Schafer, Sebastian; Wang, Adam; Otake, Yoshito; Stayman, J. W.; Zbijewski, Wojciech; Kleinszig, Gerhard; Xia, Xuewei; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2013-03-01

    Intraoperative imaging could improve patient safety and quality assurance (QA) via the detection of subtle complications that might otherwise only be found hours after surgery. Such capability could therefore reduce morbidity and the need for additional intervention. Among the severe adverse events that could be more quickly detected by high-quality intraoperative imaging is acute intracranial hemorrhage (ICH), conventionally assessed using post-operative CT. A mobile C-arm capable of high-quality cone-beam CT (CBCT) in combination with advanced image reconstruction techniques is reported as a means of detecting ICH in the operating room. The system employs an isocentric C-arm with a flat-panel detector in dual gain mode, correction of x-ray scatter and beam-hardening, and a penalized likelihood (PL) iterative reconstruction method. Performance in ICH detection was investigated using a quantitative phantom focusing on (non-contrast-enhanced) blood-brain contrast, an anthropomorphic head phantom, and a porcine model with injection of fresh blood bolus. The visibility of ICH was characterized in terms of contrast-to-noise ratio (CNR) and qualitative evaluation of images by a neurosurgeon. Across a range of size and contrast of the ICH as well as radiation dose from the CBCT scan, the CNR was found to increase from ~2.2-3.7 for conventional filtered backprojection (FBP) to ~3.9-5.4 for PL at equivalent spatial resolution. The porcine model demonstrated superior ICH detectability for PL. The results support the role of high-quality mobile C-arm CBCT employing advanced reconstruction algorithms for detecting subtle complications in the operating room at lower radiation dose and lower cost than intraoperative CT scanners and/or fixedroom C-arms. Such capability could present a potentially valuable aid to patient safety and QA.

  13. Scatter correction using a primary modulator on a clinical angiography C-arm CT system.

    PubMed

    Bier, Bastian; Berger, Martin; Maier, Andreas; Kachelrieß, Marc; Ritschl, Ludwig; Müller, Kerstin; Choi, Jang-Hwan; Fahrig, Rebecca

    2017-09-01

    Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is inserted between the X-ray source and the object. This modulation enables estimation of the scatter in the projection domain by optimizing an objective function with respect to the scatter estimate. Up to now the approach has not been implemented on a clinical angiography C-arm CT system. In our work, the iPMSE method is transferred to a clinical C-arm CBCT. Additional processing steps are added in order to compensate for the C-arm scanner motion and the automatic X-ray tube current modulation. These challenges were overcome by establishing a reference modulator database and a block-matching algorithm. Experiments with phantom and experimental in vivo data were performed to evaluate the method. We show that scatter correction using primary modulation is possible on a clinical C-arm CBCT. Scatter artifacts in the reconstructions are reduced with the newly extended method. Compared to a scan with a narrow collimation, our approach showed superior results with an improvement of the contrast and the contrast-to-noise ratio for the phantom experiments. In vivo data are evaluated by comparing the results with a scan with a narrow collimation and with a constant scatter correction approach. Scatter correction using primary modulation is possible on a clinical CBCT by compensating for the scanner motion and the tube current modulation. Scatter artifacts could be reduced in the reconstructions of phantom scans and in experimental in vivo data. © 2017 American Association of Physicists in Medicine.

  14. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    PubMed

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P < .0001) and quantitative (P < .001) analyses showed significant reduction of the metal artifacts after application of the Metal Artifact Reduction prototype software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  15. Does the choice of mobile C-arms lead to a reduction of the intraoperative radiation dose?

    PubMed

    Richter, P H; Steinbrener, J; Schicho, A; Gebhard, F

    2016-08-01

    Mobile C-arm imaging is commonly used in operating rooms worldwide. Especially in orthopaedic surgery, intraoperative C-arms are used on a daily basis. Because of new minimally-invasive surgical procedures a development in intraoperative imaging is required. The purpose of this article is investigate if the choice of mobile C-arms with flat panel detector technology (Siemens Cios Alpha and Ziehm Vision RFD) influences image quality and dose using standard, commercially available test devices. For a total of four clinical application settings, two zoom formats, and all dose levels provided, the transmission dose was measured and representative images were recorded for each test device. The data was scored by four observers to assess low contrast and spatial resolution performance. The results were converted to a relative image quality figure allowing for a direct image quality and dose comparison of the two systems. For one test device, the Cios Alpha system achieved equivalent (within the inter-observer standard error) or better low contrast resolution scores at significantly lower dose levels, while the results of the other test device suggested that both systems achieved similar image quality at the same dose. The Cios Alpha system achieved equivalent or better spatial resolution at significantly lower dose for all application settings except for Cardiac, where a comparable spatial resolution was achieved at the same dose. The correct choice of a mobile C-arm is very important, because it can lead to a reduction of the intraoperative radiation dose without negative effects on image quality. This can be a big advantage to reduce intraoperative radiation not only for the patient but also for the entire OR-team. Copyright © 2016. Published by Elsevier Ltd.

  16. Evaluation of Collaterals and Clot Burden Using Time-Resolved C-Arm Conebeam CT Angiography in the Angiography Suite: A Feasibility Study.

    PubMed

    Yang, P; Niu, K; Wu, Y; Struffert, T; Doerfler, A; Holter, P; Aagaard-Kienitz, B; Strother, C; Chen, G-H

    2017-04-01

    The assessment of collaterals and clot burden in patients with acute ischemic stroke provides important information about treatment options and clinical outcome. Time-resolved C-arm conebeam CT angiography has the potential to provide accurate and reliable evaluations of collaterals and clot burden in the angiographic suite. Experience with this technique is extremely limited, and feasibility studies are needed to validate this technique. Our purpose was to present such a feasibility study. Ten C-arm conebeam CT perfusion datasets from 10 subjects with acute ischemic stroke acquired before endovascular treatment were retrospectively processed to generate time-resolved conebeam CTA. From time-resolved conebeam CTA, 2 experienced readers evaluated the clot burden and collateral flow in consensus by using previously reported scoring systems and assessed the clinical value of this novel imaging technique independently. Interobserver agreement was analyzed by using the intraclass correlation analysis method. Clot burden and collateral flow can be assessed by using the commonly accepted scoring systems for all eligible cases. Additional clinical information (eg, the quantitative dynamic information of collateral flow) can be obtained from this new imaging technique. Two readers agreed that time-revolved C-arm conebeam CTA is the preferred method for evaluating the clot burden and collateral flow compared with other conventional imaging methods. Comprehensive evaluations of clot burden and collateral flow are feasible by using time-resolved C-arm conebeam CTA data acquired in the angiography suite. This technique further enriches the imaging tools in the angiography suite to enable a "one-stop- shop" imaging workflow for patients with acute ischemic stroke. © 2017 by American Journal of Neuroradiology.

  17. Motor vehicle accident or driver suicide? Identifying cases of failed driver suicide in the trauma setting.

    PubMed

    Henderson, Antony F; Joseph, Anthony P

    2012-01-01

    Many authors have suggested that some road traffic crashes are disguised suicide attempts. A case report and literature review is used to explore this claim and to examine the frequency and risk factors associated with driver suicide. The author concludes the methodological difficulty of establishing the driver's intent of suicide accounts for an under-estimation of the frequency of this event and that many cases of driver suicide go unrecognised. Familiarity with the risk factors associated with driver suicide may assist in the identification of cases of failed driver suicide and referral to psychiatric services. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Active noise control using noise source having adaptive resonant frequency tuning through variable ring loading

    NASA Technical Reports Server (NTRS)

    Rajiyah, Harindra (Inventor); Pla, Frederic G. (Inventor); Hedeen, Robert A. (Inventor); Renshaw, Anthony A. (Inventor)

    1995-01-01

    A noise source for an aircraft engine active noise cancellation system in which the resonant frequency of noise radiating structure is tuned to permit noise cancellation over a wide range of frequencies. The resonant frequency of the noise radiating structure is tuned by a plurality of drivers arranged to contact the noise radiating structure. Excitation of the drivers causes expansion or contraction of the drivers, thereby varying the edge loading applied to the noise radiating structure. The drivers are actuated by a controller which receives input of a feedback signal proportional to displacement of the noise radiating element and a signal corresponding to the blade passage frequency of the engine's fan. In response, the controller determines a control signal which is sent to the drivers, causing them to expand or contract. The noise radiating structure may be either the outer shroud of the engine or a ring mounted flush with an inner wall of the shroud or disposed in the interior of the shroud.

  19. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, C; Yao, W; Farr, J

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flatmore » panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre-treatment position verification.« less

  20. Hand and body radiation exposure with the use of mini C-arm fluoroscopy.

    PubMed

    Tuohy, Christopher J; Weikert, Douglas R; Watson, Jeffry T; Lee, Donald H

    2011-04-01

    To determine whole body and hand radiation exposure to the hand surgeon wearing a lead apron during routine intraoperative use of the mini C-arm fluoroscope. Four surgeons (3 hand attending surgeons and 1 hand fellow) monitored their radiation exposure for a total of 200 consecutive cases (50 cases per surgeon) requiring mini C-arm fluoroscopy. Each surgeon measured radiation exposure with a badge dosimeter placed on the outside breast pocket of the lead apron (external whole body exposure), a second badge dosimeter under the lead apron (shielded whole body exposure), and a ring dosimeter (hand exposure). Completed records were noted in 198 cases, with an average fluoroscopy time of 133.52 seconds and average cumulative dose of 19,260 rem-cm(2) per case. The total measured radiation exposures for the (1) external whole body exposure dosimeters were 16 mrem (for shallow depth), 7 mrem (for eye depth), and less than 1 mrem (for deep depth); (2) shielded whole body badge dosimeters recorded less than 1 mrem; and (3) ring dosimeters totaled 170 mrem. The total radial exposure for 4 ring dosimeters that had registered a threshold of 30 mrem or more of radiation exposure was 170 mrem at the skin level, for an average of 42.5 mrem per dosimeter ring or 6.3 mrem per case. This study of whole body and hand radiation exposure from the mini C-arm includes the largest number of surgical cases in the published literature. The measured whole body and hand radiation exposure received by the hand surgeon from the mini C-arm represents a minimal risk of radiation, based on the current National Council on Radiation Protection and Management standards of annual dose limits (5,000 mrem per year for whole body and 50,000 mrem per year to the extremities). Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Comparison Perioperative Factors During Minimally Invasive Pre-Psoas Lateral Interbody Fusion of the Lumbar Spine Using Either Navigation or Conventional Fluoroscopy

    PubMed Central

    Zhang, Yue-Hui; White, Ian; Potts, Eric; Mobasser, Jean-Pierre

    2017-01-01

    Study Design: Retrospective clinical study. Objectives: The aim of this study was to compare intraoperative conditions and clinical results of patients undergoing pre-psoas oblique lateral interbody fusion (OLIF) using navigation or conventional fluoroscopy (C-ARM) techniques. Methods: Forty-two patients (22 patients by navigation and 20 by fluoroscopy) underwent the OLIF procedure at 2 medical centers, and records were reviewed. Clinical data was collected and compared between the 2 groups. Patients were followed-up with a range of 6 to 24 months. Results: There were no significant differences on demographic data between groups. The navigation group had zero radiation exposure (RE) to the surgeon and radiation time compared to the C-ARM group, with total RE of 44.59 ± 26.65 mGy and radiation time of 88.30 ± 58.28 seconds (P < .05). The RE to the patient was significantly lower in the O-ARM group (9.38 mGy) compared to the C-ARM group (44.59 ± 26.65 mGy). Operating room time was slightly longer in the navigation group (2.49 ± 1.35 hours) compared to the C-ARM group (2.30 ± 1.17 hours; P > .05), although not statistically significant. No differences were found in estimated blood loss, length of hospitalization, surgery-related complications, and outcome scores with an average of 8-month follow-up. Conclusions: Compared with C-ARM techniques, using navigation can eliminate RE to surgeon and decrease RE to the patient, and it had no significant effect on operating time, estimated blood loss, length of hospitalization, or perioperative complications in the patients with OLIF procedure. This study shows that navigation is a safe alternative to fluoroscopy during the OLIF procedure in the treatment of degenerative lumbar conditions. PMID:28989845

  2. Self-Calibration of Cone-Beam CT Geometry Using 3D-2D Image Registration: Development and Application to Task-Based Imaging with a Robotic C-Arm

    PubMed Central

    Ouadah, S.; Stayman, J. W.; Gang, G.; Uneri, A.; Ehtiati, T.; Siewerdsen, J. H.

    2015-01-01

    Purpose Robotic C-arm systems are capable of general noncircular orbits whose trajectories can be driven by the particular imaging task. However obtaining accurate calibrations for reconstruction in such geometries can be a challenging problem. This work proposes a method to perform a unique geometric calibration of an arbitrary C-arm orbit by registering 2D projections to a previously acquired 3D image to determine the transformation parameters representing the system geometry. Methods Experiments involved a cone-beam CT (CBCT) bench system, a robotic C-arm, and three phantoms. A robust 3D-2D registration process was used to compute the 9 degree of freedom (DOF) transformation between each projection and an existing 3D image by maximizing normalized gradient information with a digitally reconstructed radiograph (DRR) of the 3D volume. The quality of the resulting “self-calibration” was evaluated in terms of the agreement with an established calibration method using a BB phantom as well as image quality in the resulting CBCT reconstruction. Results The self-calibration yielded CBCT images without significant difference in spatial resolution from the standard (“true”) calibration methods (p-value >0.05 for all three phantoms), and the differences between CBCT images reconstructed using the “self” and “true” calibration methods were on the order of 10−3 mm−1. Maximum error in magnification was 3.2%, and back-projection ray placement was within 0.5 mm. Conclusion The proposed geometric “self” calibration provides a means for 3D imaging on general non-circular orbits in CBCT systems for which a geometric calibration is either not available or not reproducible. The method forms the basis of advanced “task-based” 3D imaging methods now in development for robotic C-arms. PMID:26388661

  3. Role of race in oncogenic driver prevalence and outcomes in lung adenocarcinoma: Results from the Lung Cancer Mutation Consortium.

    PubMed

    Steuer, Conor E; Behera, Madhusmita; Berry, Lynne; Kim, Sungjin; Rossi, Michael; Sica, Gabriel; Owonikoko, Taofeek K; Johnson, Bruce E; Kris, Mark G; Bunn, Paul A; Khuri, Fadlo R; Garon, Edward B; Ramalingam, Suresh S

    2016-03-01

    The discovery of oncogenic drivers has ushered in a new era for lung cancer, but the role of these mutations in different racial/ethnic minorities has been understudied. The Lung Cancer Mutation Consortium 1 (LCMC1) database was investigated to evaluate the frequency and impact of oncogenic drivers in lung adenocarcinomas in the racial/ethnic minority patient population. Patients with metastatic lung adenocarcinomas from 14 US sites were enrolled in the LCMC1. Tumor samples were collected from 2009 through 2012 with multiplex genotyping performed on 10 oncogenic drivers (KRAS, epidermal growth factor receptor [EGFR], anaplastic lymphoma kinase (ALK) rearrangements, ERBB2 [formerly human epidermal growth factor receptor 2], BRAF, PIK3CA, MET amplification, NRAS, MEK1, and AKT1). Patients were classified as white, Asian, African American (AA), or Latino. The driver mutation frequency, the treatments, and the survival from diagnosis were determined. One thousand seven patients were included. Whites represented the majority (n = 838); there were 60 AAs, 48 Asians, and 28 Latinos. Asian patients had the highest rate of oncogenic drivers with 81% (n = 39), and they were followed by Latinos with 68% (n = 19), whites with 61% (n = 511), and AAs with 53% (n = 32). For AAs, the EGFR mutation frequency was 22%, the KRAS frequency was 17%, and the ALK frequency was 4%. Asian patients were most likely to receive targeted therapies (51% vs 27% for AAs). There were no significant differences in overall survival. Differences were observed in the prevalence of oncogenic drivers in lung adenocarcinomas and in subsequent treatments among racial groups. The lowest frequency of drivers was seen for AA patients; however, more than half of AA patients had a driver, and those treated with targeted therapy had outcomes similar to those of other races. Cancer 2016;122:766-772. © 2015 American Cancer Society. © 2015 American Cancer Society.

  4. Identification of constrained cancer driver genes based on mutation timing.

    PubMed

    Sakoparnig, Thomas; Fried, Patrick; Beerenwinkel, Niko

    2015-01-01

    Cancer drivers are genomic alterations that provide cells containing them with a selective advantage over their local competitors, whereas neutral passengers do not change the somatic fitness of cells. Cancer-driving mutations are usually discriminated from passenger mutations by their higher degree of recurrence in tumor samples. However, there is increasing evidence that many additional driver mutations may exist that occur at very low frequencies among tumors. This observation has prompted alternative methods for driver detection, including finding groups of mutually exclusive mutations and incorporating prior biological knowledge about gene function or network structure. Dependencies among drivers due to epistatic interactions can also result in low mutation frequencies, but this effect has been ignored in driver detection so far. Here, we present a new computational approach for identifying genomic alterations that occur at low frequencies because they depend on other events. Unlike passengers, these constrained mutations display punctuated patterns of occurrence in time. We test this driver-passenger discrimination approach based on mutation timing in extensive simulation studies, and we apply it to cross-sectional copy number alteration (CNA) data from ovarian cancer, CNA and single-nucleotide variant (SNV) data from breast tumors and SNV data from colorectal cancer. Among the top ranked predicted drivers, we find low-frequency genes that have already been shown to be involved in carcinogenesis, as well as many new candidate drivers. The mutation timing approach is orthogonal and complementary to existing driver prediction methods. It will help identifying from cancer genome data the alterations that drive tumor progression.

  5. PKM2 methylation by CARM1 activates aerobic glycolysis to promote tumorigenesis

    PubMed Central

    Liu, Fabao; Ma, Fengfei; Wang, Yuyuan; Hao, Ling; Zeng, Hao; Jia, Chenxi; Wang, Yidan; Liu, Peng; Ong, Irene M; Li, Baobin; Chen, Guojun; Jiang, Jiaoyang; Gong, Shaoqin; Li, Lingjun; Xu, Wei

    2017-01-01

    Metabolic reprogramming is a hallmark of cancer. Herein we discovered that the key glycolytic enzyme pyruvate kinase M2 isoform (PKM2), but not the related isoform PKM1, is methylated by co-activator associated arginine methyltransferase 1 (CARM1). PKM2 methylation reversibly shifts the balance of metabolism from oxidative phosphorylation to aerobic glycolysis in breast cancer cells. Oxidative phosphorylation depends on mitochondria calcium concentration, which becomes critical for cancer cell survival when PKM2 methylation is blocked. By interacting with and suppressing the expression of inositol 1, 4, 5-trisphosphate receptors (IP3Rs), methylated PKM2 inhibits the influx of calcium from endoplasmic reticulum (ER) to mitochondria. Inhibiting PKM2 methylation with a competitive peptide delivered by nanoparticle perturbs metabolic energy balance in cancer cells, leading to decrease of cell proliferation, migration, and metastasis. Collectively, the CARM1-PKM2 axis serves as a metabolic reprogramming mechanism in tumorigenesis, and inhibiting PKM2 methylation generates metabolic vulnerability to IP3R-dependent mitochondrial functions. PMID:29058718

  6. Camera-augmented mobile C-arm (CamC): A feasibility study of augmented reality imaging in the operating room.

    PubMed

    von der Heide, Anna Maria; Fallavollita, Pascal; Wang, Lejing; Sandner, Philipp; Navab, Nassir; Weidert, Simon; Euler, Ekkehard

    2018-04-01

    In orthopaedic trauma surgery, image-guided procedures are mostly based on fluoroscopy. The reduction of radiation exposure is an important goal. The purpose of this work was to investigate the impact of a camera-augmented mobile C-arm (CamC) on radiation exposure and the surgical workflow during a first clinical trial. Applying a workflow-oriented approach, 10 general workflow steps were defined to compare the CamC to traditional C-arms. The surgeries included were arbitrarily identified and assigned to the study. The evaluation criteria were radiation exposure and operation time for each workflow step and the entire surgery. The evaluation protocol was designed and conducted in a single-centre study. The radiation exposure was remarkably reduced by 18 X-ray shots 46% using the CamC while keeping similar surgery times. The intuitiveness of the system, its easy integration into the surgical workflow, and its great potential to reduce radiation have been demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.

  7. PKM2 methylation by CARM1 activates aerobic glycolysis to promote tumorigenesis.

    PubMed

    Liu, Fabao; Ma, Fengfei; Wang, Yuyuan; Hao, Ling; Zeng, Hao; Jia, Chenxi; Wang, Yidan; Liu, Peng; Ong, Irene M; Li, Baobin; Chen, Guojun; Jiang, Jiaoyang; Gong, Shaoqin; Li, Lingjun; Xu, Wei

    2017-11-01

    Metabolic reprogramming is a hallmark of cancer. Herein we discover that the key glycolytic enzyme pyruvate kinase M2 isoform (PKM2), but not the related isoform PKM1, is methylated by co-activator-associated arginine methyltransferase 1 (CARM1). PKM2 methylation reversibly shifts the balance of metabolism from oxidative phosphorylation to aerobic glycolysis in breast cancer cells. Oxidative phosphorylation depends on mitochondrial calcium concentration, which becomes critical for cancer cell survival when PKM2 methylation is blocked. By interacting with and suppressing the expression of inositol-1,4,5-trisphosphate receptors (InsP 3 Rs), methylated PKM2 inhibits the influx of calcium from the endoplasmic reticulum to mitochondria. Inhibiting PKM2 methylation with a competitive peptide delivered by nanoparticles perturbs the metabolic energy balance in cancer cells, leading to a decrease in cell proliferation, migration and metastasis. Collectively, the CARM1-PKM2 axis serves as a metabolic reprogramming mechanism in tumorigenesis, and inhibiting PKM2 methylation generates metabolic vulnerability to InsP 3 R-dependent mitochondrial functions.

  8. Self-calibration of cone-beam CT geometry using 3D–2D image registration

    PubMed Central

    Ouadah, S; Stayman, J W; Gang, G J; Ehtiati, T; Siewerdsen, J H

    2016-01-01

    Robotic C-arms are capable of complex orbits that can increase field of view, reduce artifacts, improve image quality, and/or reduce dose; however, it can be challenging to obtain accurate, reproducible geometric calibration required for image reconstruction for such complex orbits. This work presents a method for geometric calibration for an arbitrary source-detector orbit by registering 2D projection data to a previously acquired 3D image. It also yields a method by which calibration of simple circular orbits can be improved. The registration uses a normalized gradient information similarity metric and the covariance matrix adaptation-evolution strategy optimizer for robustness against local minima and changes in image content. The resulting transformation provides a ‘self-calibration’ of system geometry. The algorithm was tested in phantom studies using both a cone-beam CT (CBCT) test-bench and a robotic C-arm (Artis Zeego, Siemens Healthcare) for circular and non-circular orbits. Self-calibration performance was evaluated in terms of the full-width at half-maximum (FWHM) of the point spread function in CBCT reconstructions, the reprojection error (RPE) of steel ball bearings placed on each phantom, and the overall quality and presence of artifacts in CBCT images. In all cases, self-calibration improved the FWHM—e.g. on the CBCT bench, FWHM = 0.86 mm for conventional calibration compared to 0.65 mm for self-calibration (p < 0.001). Similar improvements were measured in RPE—e.g. on the robotic C-arm, RPE = 0.73 mm for conventional calibration compared to 0.55 mm for self-calibration (p < 0.001). Visible improvement was evident in CBCT reconstructions using self-calibration, particularly about high-contrast, high-frequency objects (e.g. temporal bone air cells and a surgical needle). The results indicate that self-calibration can improve even upon systems with presumably accurate geometric calibration and is applicable to situations where conventional calibration is not feasible, such as complex non-circular CBCT orbits and systems with irreproducible source-detector trajectory. PMID:26961687

  9. Self-calibration of cone-beam CT geometry using 3D-2D image registration

    NASA Astrophysics Data System (ADS)

    Ouadah, S.; Stayman, J. W.; Gang, G. J.; Ehtiati, T.; Siewerdsen, J. H.

    2016-04-01

    Robotic C-arms are capable of complex orbits that can increase field of view, reduce artifacts, improve image quality, and/or reduce dose; however, it can be challenging to obtain accurate, reproducible geometric calibration required for image reconstruction for such complex orbits. This work presents a method for geometric calibration for an arbitrary source-detector orbit by registering 2D projection data to a previously acquired 3D image. It also yields a method by which calibration of simple circular orbits can be improved. The registration uses a normalized gradient information similarity metric and the covariance matrix adaptation-evolution strategy optimizer for robustness against local minima and changes in image content. The resulting transformation provides a ‘self-calibration’ of system geometry. The algorithm was tested in phantom studies using both a cone-beam CT (CBCT) test-bench and a robotic C-arm (Artis Zeego, Siemens Healthcare) for circular and non-circular orbits. Self-calibration performance was evaluated in terms of the full-width at half-maximum (FWHM) of the point spread function in CBCT reconstructions, the reprojection error (RPE) of steel ball bearings placed on each phantom, and the overall quality and presence of artifacts in CBCT images. In all cases, self-calibration improved the FWHM—e.g. on the CBCT bench, FWHM  =  0.86 mm for conventional calibration compared to 0.65 mm for self-calibration (p  <  0.001). Similar improvements were measured in RPE—e.g. on the robotic C-arm, RPE  =  0.73 mm for conventional calibration compared to 0.55 mm for self-calibration (p  <  0.001). Visible improvement was evident in CBCT reconstructions using self-calibration, particularly about high-contrast, high-frequency objects (e.g. temporal bone air cells and a surgical needle). The results indicate that self-calibration can improve even upon systems with presumably accurate geometric calibration and is applicable to situations where conventional calibration is not feasible, such as complex non-circular CBCT orbits and systems with irreproducible source-detector trajectory.

  10. 3D/2D image registration method for joint motion analysis using low-quality images from mini C-arm machines

    NASA Astrophysics Data System (ADS)

    Ghafurian, Soheil; Hacihaliloglu, Ilker; Metaxas, Dimitris N.; Tan, Virak; Li, Kang

    2017-03-01

    A 3D kinematic measurement of joint movement is crucial for orthopedic surgery assessment and diagnosis. This is usually obtained through a frame-by-frame registration of the 3D bone volume to a fluoroscopy video of the joint movement. The high cost of a high-quality fluoroscopy imaging system has hindered the access of many labs to this application. This is while the more affordable and low-dosage version, the mini C-arm, is not commonly used for this application due to low image quality. In this paper, we introduce a novel method for kinematic analysis of joint movement using the mini C-arm. In this method the bone of interest is recovered and isolated from the rest of the image using a non-rigid registration of an atlas to each frame. The 3D/2D registration is then performed using the weighted histogram of image gradients as an image feature. In our experiments, the registration error was 0.89 mm and 2.36° for human C2 vertebra. While the precision is still lacking behind a high quality fluoroscopy machine, it is a good starting point facilitating the use of mini C-arms for motion analysis making this application available to lower-budget environments. Moreover, the registration was highly resistant to the initial distance from the true registration, converging to the answer from anywhere within +/-90° of it.

  11. Control of energy sweep and transverse beam motion in induction linacs

    NASA Astrophysics Data System (ADS)

    Turner, W. C.

    1991-05-01

    Recent interest in the electron induction accelerator has focussed on its application as a driver for high power radiation sources; free electron laser (FEL), relativistic klystron (RK) and cyclotron autoresonance maser (CARM). In the microwave regime where many successful experiments have been carried out, typical beam parameters are: beam energy 1 to 10 MeV, current 1 to 3 kA and pulse width 50 nsec. Radiation source applications impose conditions on electron beam quality, as characterized by three parameters; energy sweep, transverse beam motion and brightness. These conditions must be maintained for the full pulse duration to assure high efficiency conversion of beam power to radiation. The microwave FEL that has been analyzed in the greatest detail requires energy sweep less than (+ or -) 1 pct., transverse beam motion less than (+ or -) 1 mm and brightness approx. 1 x 10(exp 8)A/sq m sq rad. In the visible region the requirements on these parameters become roughly an order of magnitude more strigent. With the ETAII accelerator at LLNL the requirements were achieved for energy sweep, transverse beam motion and brightness. The recent data and the advances that have made the improved beam quality possible are discussed. The most important advances are: understanding of focussing magnetic field errors and improvements in alignment of the magnetic axis, a redesign of the high voltage pulse distribution system between the magnetic compression modulators and the accelerator cells, and exploitation of a beam tuning algorithm for minimizing transverse beam motion. The prospects are briefly described for increasing the pulse repetition frequency to the range of 5 kHz and a delayed feedback method of regulating beam energy over very long pulse bursts, thus making average power megawatt level microwave sources at 140 GHz and above a possibility.

  12. Identification of Constrained Cancer Driver Genes Based on Mutation Timing

    PubMed Central

    Sakoparnig, Thomas; Fried, Patrick; Beerenwinkel, Niko

    2015-01-01

    Cancer drivers are genomic alterations that provide cells containing them with a selective advantage over their local competitors, whereas neutral passengers do not change the somatic fitness of cells. Cancer-driving mutations are usually discriminated from passenger mutations by their higher degree of recurrence in tumor samples. However, there is increasing evidence that many additional driver mutations may exist that occur at very low frequencies among tumors. This observation has prompted alternative methods for driver detection, including finding groups of mutually exclusive mutations and incorporating prior biological knowledge about gene function or network structure. Dependencies among drivers due to epistatic interactions can also result in low mutation frequencies, but this effect has been ignored in driver detection so far. Here, we present a new computational approach for identifying genomic alterations that occur at low frequencies because they depend on other events. Unlike passengers, these constrained mutations display punctuated patterns of occurrence in time. We test this driver–passenger discrimination approach based on mutation timing in extensive simulation studies, and we apply it to cross-sectional copy number alteration (CNA) data from ovarian cancer, CNA and single-nucleotide variant (SNV) data from breast tumors and SNV data from colorectal cancer. Among the top ranked predicted drivers, we find low-frequency genes that have already been shown to be involved in carcinogenesis, as well as many new candidate drivers. The mutation timing approach is orthogonal and complementary to existing driver prediction methods. It will help identifying from cancer genome data the alterations that drive tumor progression. PMID:25569148

  13. Simple, low-noise piezo driver with feed-forward for broad tuning of external cavity diode lasers.

    PubMed

    Doret, S Charles

    2018-02-01

    We present an inexpensive, low-noise (<260 μV rms , 0.1 Hz-100 kHz) design for a piezo driver suitable for frequency tuning of external-cavity diode lasers. This simple driver improves upon many commercially available drivers by incorporating circuitry to produce a "feed-forward" signal appropriate for making simultaneous adjustments to the piezo voltage and laser current, enabling dramatic improvements in a mode-hop-free laser frequency tuning range. We present the theory behind our driver's operation, characterize its output noise, and demonstrate its use in absorption spectroscopy on the rubidium D 1 line.

  14. Pattern of seat belt use by drivers in Trinidad and Tobago, West Indies

    PubMed Central

    2011-01-01

    Background In Trinidad and Tobago, the law on the mandatory use of seat belts was passed in 1995, but this law is hardly enforced. The objective of this study was to determine the frequency and predictors of seat belt use by motor vehicle drivers in the country. Findings A cross-sectional study of 959 motor vehicle drivers using a self-administered questionnaire. Data analysis included Pearson Chi square test and multinomial logistic regression analysis in order to determine the possible predictors of seat belt use by the drivers in Trinidad and Tobago. A majority of the drivers sometimes (51.8%) or always (31.6%) use a seat belt. About 16.7%, 29% and 54.2% of the drivers perceived that the other drivers use their seat belts more frequently, with the same frequency and less frequently respectively compared to themselves. The main reason for not using seat belt by the drivers was given as frequent stops (40.7%) and the main motivation to use seat belt by the drivers was given as stiffer penalties for non-compliance with the seat belt law (44.5%). The predictors of seat belt use were male driver, no formal or lower level of education, driving for less than 10 years, and the perception that the other drivers use seat belts with the same or higher frequency compared to the respondents. Conclusion Only a small proportion of the drivers in Trinidad and Tobago always use a seat belt when driving. There is the need to enforce the seat belt legislation in the country. PMID:21679410

  15. Noise induced hearing loss risk assessment in truck drivers.

    PubMed

    Karimi, Ali; Nasiri, Saleh; Kazerooni, Farshid Khodaparast; Oliaei, Mohammad

    2010-01-01

    Hearing sense is one of the key elements which may have impact on the driver's task quality. This cross-sectional study investigates the hearing status of 500 truck drivers by pure tone audiometry (AC) in one of the cities in Fars province, Iran. Hearing threshold levels of the subjects were measured in frequencies of 500Hz-8000Hz. Screening and determination of permanent threshold shift (PTS) was the first aim of this study. Hence tests were done at least 16 hours after any exposure to noticeable sound. The effect of age as a confounding factor was considered using ISO equation and subtracted from whole hearing threshold. The threshold of 25 dB HL and above was considered abnormal but the calculation of hearing was also carried out using 0 dB HL as reference. Subjects were categorized into two groups on the basis of working experience and the hearing threshold of 25 dB was considered a boundary of normal hearing sense. The results of Pearson Chi-Square test showed that working experience as an independent variable has significant contributing effect on hearing thresholds of truck drivers in frequencies of 500, 1000, 2000 and 4000 Hz (p greater than 0.05). Also, it was shown that currently nine and 12.6 % of truck drivers suffer from impaired hearing sense in left and right respectively (hearing threshold level greater than 25 dB) in mid frequencies (500, 1000, 2000 Hz) and 45% in high frequencies of both ears (4000 and 8000 Hz). The results indicated that hearing damage of professional drivers was expected to occur sooner at 4000 and 8000 Hz than lower frequencies. Finally it was deduced that the occupational conditions of truck drivers may have bilateral, symmetrical harmful effect on hearing threshold sense in all frequencies mainly in frequency of 4000 Hz, so health surveillance programs such as education and periodic medical examinations are emphasized for pre-diagnosing and prevention of any possible impairment and an urgent need to take up some interventions such as better maintenance of roads, automobile industry efforts to reduce the noise level emission of vehicles and reducing number of working hours per day of drivers are highlighted to improve the harmful working conditions of truck drivers.

  16. Reduction of low frequency vibration of truck driver and seating system through system parameter identification, sensitivity analysis and active control

    NASA Astrophysics Data System (ADS)

    Wang, Xu; Bi, Fengrong; Du, Haiping

    2018-05-01

    This paper aims to develop an 5-degree-of-freedom driver and seating system model for optimal vibration control. A new method for identification of the driver seating system parameters from experimental vibration measurement has been developed. The parameter sensitivity analysis has been conducted considering the random excitation frequency and system parameter uncertainty. The most and least sensitive system parameters for the transmissibility ratio have been identified. The optimised PID controllers have been developed to reduce the driver's body vibration.

  17. Estimation of automobile-driver describing function from highway tests using the double steering wheel

    NASA Technical Reports Server (NTRS)

    Delp, P.; Crossman, E. R. F. W.; Szostak, H.

    1972-01-01

    The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.

  18. Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

    NASA Astrophysics Data System (ADS)

    Wang, Adam S.; Webster Stayman, J.; Otake, Yoshito; Kleinszig, Gerhard; Vogt, Sebastian; Gallia, Gary L.; Khanna, A. Jay; Siewerdsen, Jeffrey H.

    2014-02-01

    The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (˜40-80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4-2.2× over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ˜1.7 mGy and benefits from 50% sparsity at dose below ˜1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose.

  19. Spine segmentation from C-arm CT data sets: application to region-of-interest volumes for spinal interventions

    NASA Astrophysics Data System (ADS)

    Buerger, C.; Lorenz, C.; Babic, D.; Hoppenbrouwers, J.; Homan, R.; Nachabe, R.; Racadio, J. M.; Grass, M.

    2017-03-01

    Spinal fusion is a common procedure to stabilize the spinal column by fixating parts of the spine. In such procedures, metal screws are inserted through the patients back into a vertebra, and the screws of adjacent vertebrae are connected by metal rods to generate a fixed bridge. In these procedures, 3D image guidance for intervention planning and outcome control is required. Here, for anatomical guidance, an automated approach for vertebra segmentation from C-arm CT images of the spine is introduced and evaluated. As a prerequisite, 3D C-arm CT images are acquired covering the vertebrae of interest. An automatic model-based segmentation approach is applied to delineate the outline of the vertebrae of interest. The segmentation approach is based on 24 partial models of the cervical, thoracic and lumbar vertebrae which aggregate information about (i) the basic shape itself, (ii) trained features for image based adaptation, and (iii) potential shape variations. Since the volume data sets generated by the C-arm system are limited to a certain region of the spine the target vertebra and hence initial model position is assigned interactively. The approach was trained and tested on 21 human cadaver scans. A 3-fold cross validation to ground truth annotations yields overall mean segmentation errors of 0.5 mm for T1 to 1.1 mm for C6. The results are promising and show potential to support the clinician in pedicle screw path and rod planning to allow accurate and reproducible insertions.

  20. A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance.

    PubMed

    Hua, Chiaho; Yao, Weiguang; Kidani, Takao; Tomida, Kazuo; Ozawa, Saori; Nishimura, Takenori; Fujisawa, Tatsuya; Shinagawa, Ryousuke; Merchant, Thomas E

    2017-11-01

    A ceiling-mounted robotic C-arm cone beam CT (CBCT) system was developed for use with a 190° proton gantry system and a 6-degree-of-freedom robotic patient positioner. We report on the mechanical design, system accuracy, image quality, image guidance accuracy, imaging dose, workflow, safety and collision-avoidance. The robotic CBCT system couples a rotating C-ring to the C-arm concentrically with a kV X-ray tube and a flat-panel imager mounted to the C-ring. CBCT images are acquired with flex correction and maximally 360° rotation for a 53 cm field of view. The system was designed for clinical use with three imaging locations. Anthropomorphic phantoms were imaged to evaluate the image guidance accuracy. The position accuracy and repeatability of the robotic C-arm was high (<0.5 mm), as measured with a high-accuracy laser tracker. The isocentric accuracy of the C-ring rotation was within 0.7 mm. The coincidence of CBCT imaging and radiation isocentre was better than 1 mm. The average image guidance accuracy was within 1 mm and 1° for the anthropomorphic phantoms tested. Daily volumetric imaging for proton patient positioning was specified for routine clinical practice. Our novel gantry-independent robotic CBCT system provides high-accuracy volumetric image guidance for proton therapy. Advances in knowledge: Ceiling-mounted robotic CBCT provides a viable option than CT on-rails for partial gantry and fixed-beam proton systems with the added advantage of acquiring images at the treatment isocentre.

  1. Extended ellipse-line-ellipse trajectory for long-object cone-beam imaging with a mounted C-arm system

    NASA Astrophysics Data System (ADS)

    Yu, Zhicong; Lauritsch, Günter; Dennerlein, Frank; Mao, Yanfei; Hornegger, Joachim; Noo, Frédéric

    2016-02-01

    Recent reports show that three-dimensional cone-beam (CB) imaging with a floor-mounted (or ceiling-mounted) C-arm system has become a valuable tool in interventional radiology. Currently, a circular short scan is used for data acquisition, which inevitably yields CB artifacts and a short coverage in the direction of the patient table. To overcome these two limitations, a more sophisticated data acquisition geometry is needed. This geometry should be complete in terms of Tuy’s condition and should allow continuous scanning, while being compatible with the mechanical constraints of mounted C-arm systems. Additionally, the geometry should allow accurate image reconstruction from truncated data. One way to ensure such a feature is to adopt a trajectory that provides full R-line coverage within the field-of-view (FOV). An R-line is any segment of line that connects two points on a source trajectory, and the R-line coverage is the set of points that belong to an R-line. In this work, we propose a novel geometry called the extended ellipse-line-ellipse (ELE) for long-object imaging with a mounted C-arm system. This trajectory is built from modules consisting of two elliptical arcs connected by a line. We demonstrate that the extended ELE can be configured in many ways so that full R-line coverage is guaranteed. Both tight and relaxed parametric settings are presented. All results are supported by extensive mathematical proofs provided in appendices. Our findings make the extended ELE trajectory attractive for axially-extended FOV imaging in interventional radiology.

  2. Online C-arm calibration using a marked guide wire for 3D reconstruction of pulmonary arteries

    NASA Astrophysics Data System (ADS)

    Vachon, Étienne; Miró, Joaquim; Duong, Luc

    2017-03-01

    3D reconstruction of vessels from 2D X-ray angiography is highly relevant to improve the visualization and the assessment of vascular structures such as pulmonary arteries by interventional cardiologists. However, to ensure a robust and accurate reconstruction, C-arm gantry parameters must be properly calibrated to provide clinically acceptable results. Calibration procedures often rely on calibration objects and complex protocol which is not adapted to an intervention context. In this study, a novel calibration algorithm for C-arm gantry is presented using the instrumentation such as catheters and guide wire. This ensures the availability of a minimum set of correspondences and implies minimal changes to the clinical workflow. The method was evaluated on simulated data and on retrospective patient datasets. Experimental results on simulated datasets demonstrate a calibration that allows a 3D reconstruction of the guide wire up to a geometric transformation. Experiments with patients datasets show a significant decrease of the retro projection error to 0.17 mm 2D RMS. Consequently, such procedure might contribute to identify any calibration drift during the intervention.

  3. C-arm based cone-beam CT using a two-concentric-arc source trajectory: system evaluation

    NASA Astrophysics Data System (ADS)

    Zambelli, Joseph; Zhuang, Tingliang; Nett, Brian E.; Riddell, Cyril; Belanger, Barry; Chen, Guang-Hong

    2008-03-01

    The current x-ray source trajectory for C-arm based cone-beam CT is a single arc. Reconstruction from data acquired with this trajectory yields cone-beam artifacts for regions other than the central slice. In this work we present the preliminary evaluation of reconstruction from a source trajectory of two concentric arcs using a flat-panel detector equipped C-arm gantry (GE Healthcare Innova 4100 system, Waukesha, Wisconsin). The reconstruction method employed is a summation of FDK-type reconstructions from the two individual arcs. For the angle between arcs studied here, 30°, this method offers a significant reduction in the visibility of cone-beam artifacts, with the additional advantages of simplicity and ease of implementation due to the fact that it is a direct extension of the reconstruction method currently implemented on commercial systems. Reconstructed images from data acquired from the two arc trajectory are compared to those reconstructed from a single arc trajectory and evaluated in terms of spatial resolution, low contrast resolution, noise, and artifact level.

  4. C-arm based cone-beam CT using a two-concentric-arc source trajectory: system evaluation.

    PubMed

    Zambelli, Joseph; Zhuang, Tingliang; Nett, Brian E; Riddell, Cyril; Belanger, Barry; Chen, Guang-Hong

    2008-01-01

    The current x-ray source trajectory for C-arm based cone-beam CT is a single arc. Reconstruction from data acquired with this trajectory yields cone-beam artifacts for regions other than the central slice. In this work we present the preliminary evaluation of reconstruction from a source trajectory of two concentric arcs using a flat-panel detector equipped C-arm gantry (GE Healthcare Innova 4100 system, Waukesha, Wisconsin). The reconstruction method employed is a summation of FDK-type reconstructions from the two individual arcs. For the angle between arcs studied here, 30°, this method offers a significant reduction in the visibility of cone-beam artifacts, with the additional advantages of simplicity and ease of implementation due to the fact that it is a direct extension of the reconstruction method currently implemented on commercial systems. Reconstructed images from data acquired from the two arc trajectory are compared to those reconstructed from a single arc trajectory and evaluated in terms of spatial resolution, low contrast resolution, noise, and artifact level.

  5. Robust model-based 3d/3D fusion using sparse matching for minimally invasive surgery.

    PubMed

    Neumann, Dominik; Grbic, Sasa; John, Matthias; Navab, Nassir; Hornegger, Joachim; Ionasec, Razvan

    2013-01-01

    Classical surgery is being disrupted by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm CT and C-arm fluoroscopy are routinely used for intra-operative guidance. However, intra-operative modalities have limited image quality of the soft tissue and a reliable assessment of the cardiac anatomy can only be made by injecting contrast agent, which is harmful to the patient and requires complex acquisition protocols. We propose a novel sparse matching approach for fusing high quality pre-operative CT and non-contrasted, non-gated intra-operative C-arm CT by utilizing robust machine learning and numerical optimization techniques. Thus, high-quality patient-specific models can be extracted from the pre-operative CT and mapped to the intra-operative imaging environment to guide minimally invasive procedures. Extensive quantitative experiments demonstrate that our model-based fusion approach has an average execution time of 2.9 s, while the accuracy lies within expert user confidence intervals.

  6. The Safety of Physically Disabled Drivers

    PubMed Central

    Ysander, Lars

    1966-01-01

    Four hundred and ninety-four disabled drivers, the majority with loss of function in the legs usually as the result of poliomyelitis or amputations, have been studied with respect to the frequency of traffic accidents and serious traffic offences during a 10-year period. Traffic accidents which may have been caused by their disability occurred in only three (0·6%) of the total number of drivers investigated. In all three cases the driver had loss of function in the right leg. A comparison was made between the investigation series and a control series identical as regards sex, age, and licence-holding period but with a shorter exposure to traffic than the investigation series. The frequency of traffic accidents amounted to 7·1% in both series, and the frequency of serious traffic offences was 12·2% in the investigation series and 14·8% in the control series. Disabled drivers are not an increased hazard in traffic. The compensatory technical modifications to the vehicle which are generally adopted appeared to be adequate. However, there was a relatively increased frequency of accidents among drivers with loss of function in the right leg or right arm. An improvement of the technical modifications applied in these cases might result in a further reduction of the road-safety risks. PMID:4223486

  7. Development of high precision digital driver of acoustic-optical frequency shifter for ROG

    NASA Astrophysics Data System (ADS)

    Zhang, Rong; Kong, Mei; Xu, Yameng

    2016-10-01

    We develop a high precision digital driver of the acoustic-optical frequency shifter (AOFS) based on the parallel direct digital synthesizer (DDS) technology. We use an atomic clock as the phase-locked loop (PLL) reference clock, and the PLL is realized by a dual digital phase-locked loop. A DDS sampling clock up to 320 MHz with a frequency stability as low as 10-12 Hz is obtained. By constructing the RF signal measurement system, it is measured that the frequency output range of the AOFS-driver is 52-58 MHz, the center frequency of the band-pass filter is 55 MHz, the ripple in the band is less than 1 dB@3MHz, the single channel output power is up to 0.3 W, the frequency stability is 1 ppb (1 hour duration), and the frequency-shift precision is 0.1 Hz. The obtained frequency stability has two orders of improvement compared to that of the analog AOFS-drivers. For the designed binary frequency shift keying (2-FSK) and binary phase shift keying (2-PSK) modulation system, the demodulating frequency of the input TTL synchronous level signal is up to 10 kHz. The designed digital-bus coding/decoding system is compatible with many conventional digital bus protocols. It can interface with the ROG signal detecting software through the integrated drive electronics (IDE) and exchange data with the two DDS frequency-shift channels through the signal detecting software.

  8. Epigenetic Basis for the Regulation of Estrogen Receptor Alpha Activity in Breast Cancer Cells

    DTIC Science & Technology

    2009-04-01

    B) GPER and TESK2 expression after CARM1 silencing in MCF7 was determined by reverse transcription-qPCR and revealed the requirement for CARM1 in...the E2-induced repression of GPER and TESK2. siLUC was used as a control. *, P 0.05; **, P 0.01; ***, P 0.001. (C) Enrichment of Ec3 cluster...sites (blue blocks) near GPER and TESK2 E2-downregulated target genes (red blocks). 3416 LUPIEN ET AL. MOL. CELL. BIOL. at A C Q S E R V IC E /S E R IA

  9. CARM1 modulators affect epigenome of stem cells and change morphology of nucleoli.

    PubMed

    Franek, M; Legartová, S; Suchánková, J; Milite, C; Castellano, S; Sbardella, G; Kozubek, S; Bártová, E

    2015-01-01

    CARM1 interacts with numerous transcription factors to mediate cellular processes, especially gene expression. This is important for the maintenance of ESC pluripotency or intervention to tumorigenesis. Here, we studied epigenomic effects of two potential CARM1 modulators: an activator (EML159) and an inhibitor (ellagic acid dihydrate, EA). We examined nuclear morphology in human and mouse embryonic stem cells (hESCs, mESCs), as well as in iPS cells. The CARM1 modulators did not function similarly in all cell types. EA decreased the levels of the pluripotency markers, OCT4 and NANOG, particularly in iPSCs, whereas the levels of these proteins increased after EML159 treatment. EML159 treatment of mouse ESCs led to decreased levels of OCT4 and NANOG, which was accompanied by an increased level of Endo-A. The same trend was observed for NANOG and Endo-A in hESCs affected by EML159. Interestingly, EA mainly changed epigenetic features of nucleoli because a high level of arginine asymmetric di-methylation in the nucleoli of hESCs was reduced after EA treatment. ChIP-PCR of ribosomal genes confirmed significantly reduced levels of H3R17me2a, in both the promoter region of ribosomal genes and rDNA encoding 28S rRNA, after EA addition. Moreover, EA treatment changed the nuclear pattern of AgNORs (silver-stained nucleolus organizer regions) in all cell types studied. In EA-treated ESCs, AgNOR pattern was similar to the pattern of AgNORs after inhibition of RNA pol I by actinomycin D. Together, inhibitory effect of EA on arginine methylation and effect on related morphological parameters was especially observed in compartment of nucleoli.

  10. Use of C-Arm Cone Beam CT During Hepatic Radioembolization: Protocol Optimization for Extrahepatic Shunting and Parenchymal Enhancement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoven, Andor F. van den, E-mail: a.f.vandenhoven@umcutrecht.nl; Prince, Jip F.; Keizer, Bart de

    PurposeTo optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.Materials and MethodsA prospective development study was performed per IDEAL recommendations. A literature-based protocol was applied in patients with unresectable and chemorefractory liver malignancies undergoing an angiography before radioembolization. Contrast and scan settings were adjusted stepwise and repeatedly reviewed in a consensus meeting. Afterwards, two independent raters analyzed all scans. A third rater evaluated the SPECT/CT scans as a reference standard for extrahepatic shunting and lack of target segment perfusion.ResultsFifty scans were obtained in 29 procedures. The first protocol, using a 6 s delaymore » and 10 s scan, showed insufficient parenchymal enhancement. In the second protocol, the delay was determined by timing parenchymal enhancement on DSA power injection (median 8 s, range 4–10 s): enhancement improved, but breathing artifacts increased (from 0 to 27 %). Since the third protocol with a 5 s scan decremented subjective image quality, the second protocol was deemed optimal. Median CNR (range) was 1.7 (0.6–3.2), 2.2 (−1.4–4.0), and 2.1 (−0.3–3.0) for protocol 1, 2, and 3 (p = 0.80). Delineation of perfused segments was possible in 57, 73, and 44 % of scans (p = 0.13). In all C-arm CTs combined, the negative predictive value was 95 % for extrahepatic shunting and 83 % for lack of target segment perfusion.ConclusionAn optimized C-arm CT protocol was developed that can be used to detect extrahepatic shunts and non-perfusion of target segments during RE.« less

  11. Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Sungchae

    The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging qualitymore » was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)« less

  12. A Fast, Accurate and Easy to Implement Method for Pose Recognition of an Intramedullary Nail using a Tracked C-arm

    NASA Astrophysics Data System (ADS)

    Esfandiari, H.; Amiri, S.; Lichti, D. D.; Anglin, C.

    2014-06-01

    A C-arm is a mobile X-ray device that is frequently used during orthopaedic surgeries. It consists of a semi-circular, arc-shaped arm that holds an X-ray transmitter at one end and an X-ray detector at the other. Intramedullary nail (IM nail) fixation is a popular orthopaedic surgery in which a metallic rod is placed into the patient's fractured bone (femur or tibia) and fixed using metal screws. The main challenge of IM-nail fixation surgery is to achieve the X-ray shot in which the distal holes of the IM nail appear as circles (desired view) so that the surgeon can easily insert the screws. Although C-arm X-ray devices are routinely used in IM-nail fixation surgeries, the surgeons or radiation technologists (rad-techs) usually use it in a trial-and-error manner. This method raises both radiation exposure and surgery time. In this study, we have designed and developed an IM-nail distal locking navigation technique that leads to more accurate and faster screw placement with a lower radiation dose and a minimum number of added steps to the operation to make it more accepted within the orthopaedic community. The specific purpose of this study was to develop and validate an automated technique for identifying the current pose of the IM nail relative to the C-arm. An accuracy assessment was performed to test the reliability of the navigation results. Translational accuracy was demonstrated to be better than 1 mm, roll and pitch rotations better than 2° and yaw rotational accuracy better than 2-5° depending on the separate angle. Computation time was less than 3.5 seconds.

  13. Can vehicle longitudinal jerk be used to identify aggressive drivers? An examination using naturalistic driving data.

    PubMed

    Feng, Fred; Bao, Shan; Sayer, James R; Flannagan, Carol; Manser, Michael; Wunderlich, Robert

    2017-07-01

    This paper investigated the characteristics of vehicle longitudinal jerk (change rate of acceleration with respect to time) by using vehicle sensor data from an existing naturalistic driving study. The main objective was to examine whether vehicle jerk contains useful information that could be potentially used to identify aggressive drivers. Initial investigation showed that there are unique characteristics of vehicle jerk in drivers' gas and brake pedal operations. Thus two jerk-based metrics were examined: (1) driver's frequency of using large positive jerk when pressing the gas pedal, and (2) driver's frequency of using large negative jerk when pressing the brake pedal. To validate the performance of the two metrics, drivers were firstly divided into an aggressive group and a normal group using three classification methods (1) traveling at excessive speed (speeding), (2) following too closely to a front vehicle (tailgating), and (3) their association with crashes or near-crashes in the dataset. The results show that those aggressive drivers defined using any of the three methods above were associated with significantly higher values of the two jerk-based metrics. Between the two metrics the frequency of using large negative jerk seems to have better performance in identifying aggressive drivers. A sensitivity analysis shows the findings were largely consistent with varying parameters in the analysis. The potential applications of this work include developing quantitative surrogate safety measures to identify aggressive drivers and aggressive driving, which could be potentially used to, for example, provide real-time or post-ride performance feedback to the drivers, or warn the surrounding drivers or vehicles using the connected vehicle technologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Using trip diaries to mitigate route risk and risky driving behavior among older drivers.

    PubMed

    Payyanadan, Rashmi P; Maus, Adam; Sanchez, Fabrizzio A; Lee, John D; Miossi, Lillian; Abera, Amsale; Melvin, Jacob; Wang, Xufan

    2017-09-01

    To reduce exposure to risky and challenging driving situations and prolong mobility and independence, older drivers self-regulate their driving behavior. But self-regulation can be challenging because it depends on drivers' ability to assess their limitations. Studies using self-reports, survey data, and hazard and risk perception tests have shown that driving behavior feedback can help older drivers assess their limitations and adjust their driving behavior. But only limited work has been conducted in developing feedback technology interventions tailored to meet the information needs of older drivers, and the impact these interventions have in helping older drivers self-monitor their driving behavior and risk outcomes. The vehicles of 33 drivers 65 years and older were instrumented with OBD2 devices. Older drivers were provided access to customized web-based Trip Diaries that delivered post-trip feedback of the routes driven, low-risk route alternatives, and frequency of their risky driving behaviors. Data were recorded over four months, with baseline driving behavior collected for one month. Generalized linear mixed effects regression models assessed the effects of post-trip feedback on the route risk and driving behaviors of older drivers. Results showed that post-trip feedback reduced the estimated route risk of older drivers by 2.9% per week, and reduced their speeding frequency on average by 0.9% per week. Overall, the Trip Diary feedback reduced the expected crash rate from 1 in 6172 trips to 1 in 7173 trips, and the expected speeding frequency from 46% to 39%. Thus providing older drivers with tailored feedback of their driving behavior and crash risk could help them appropriately self-regulate their driving behavior, and improve their crash risk outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Keep Your Scanners Peeled: Gaze Behavior as a Measure of Automation Trust During Highly Automated Driving.

    PubMed

    Hergeth, Sebastian; Lorenz, Lutz; Vilimek, Roman; Krems, Josef F

    2016-05-01

    The feasibility of measuring drivers' automation trust via gaze behavior during highly automated driving was assessed with eye tracking and validated with self-reported automation trust in a driving simulator study. Earlier research from other domains indicates that drivers' automation trust might be inferred from gaze behavior, such as monitoring frequency. The gaze behavior and self-reported automation trust of 35 participants attending to a visually demanding non-driving-related task (NDRT) during highly automated driving was evaluated. The relationship between dispositional, situational, and learned automation trust with gaze behavior was compared. Overall, there was a consistent relationship between drivers' automation trust and gaze behavior. Participants reporting higher automation trust tended to monitor the automation less frequently. Further analyses revealed that higher automation trust was associated with lower monitoring frequency of the automation during NDRTs, and an increase in trust over the experimental session was connected with a decrease in monitoring frequency. We suggest that (a) the current results indicate a negative relationship between drivers' self-reported automation trust and monitoring frequency, (b) gaze behavior provides a more direct measure of automation trust than other behavioral measures, and (c) with further refinement, drivers' automation trust during highly automated driving might be inferred from gaze behavior. Potential applications of this research include the estimation of drivers' automation trust and reliance during highly automated driving. © 2016, Human Factors and Ergonomics Society.

  16. MO-DE-207A-06: ECG-Gated CT Reconstruction for a C-Arm Inverse Geometry X-Ray System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slagowski, JM; Dunkerley, DAP

    2016-06-15

    Purpose: To obtain ECG-gated CT images from truncated projection data acquired with a C-arm based inverse geometry fluoroscopy system, for the purpose of cardiac chamber mapping in interventional procedures. Methods: Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system with a scanned multisource x-ray tube and a photon-counting detector mounted to a C-arm. In the proposed method, SBDX short-scan rotational acquisition is performed followed by inverse geometry CT (IGCT) reconstruction and segmentation of contrast-enhanced objects. The prior image constrained compressed sensing (PICCS) framework was adapted for IGCT reconstruction to mitigate artifacts arising from data truncation and angular undersampling duemore » to cardiac gating. The performance of the reconstruction algorithm was evaluated in numerical simulations of truncated and non-truncated thorax phantoms containing a dynamic ellipsoid to represent a moving cardiac chamber. The eccentricity of the ellipsoid was varied at frequencies from 1–1.5 Hz. Projection data were retrospectively sorted into 13 cardiac phases. Each phase was reconstructed using IGCT-PICCS, with a nongated gridded FBP (gFBP) prior image. Surface accuracy was determined using Dice similarity coefficient and a histogram of the point distances between the segmented surface and ground truth surface. Results: The gated IGCT-PICCS algorithm improved surface accuracy and reduced streaking and truncation artifacts when compared to nongated gFBP. For the non-truncated thorax with 1.25 Hz motion, 99% of segmented surface points were within 0.3 mm of the 15 mm diameter ground truth ellipse, versus 1.0 mm for gFBP. For the truncated thorax phantom with a 40 mm diameter ellipse, IGCT-PICCS surface accuracy measured 0.3 mm versus 7.8 mm for gFBP. Dice similarity coefficient was 0.99–1.00 (IGCT-PICCS) versus 0.63–0.75 (gFBP) for intensity-based segmentation thresholds ranging from 25–75% maximum contrast. Conclusions: The PICCS algorithm was successfully applied to reconstruct truncated IGCT projection data with angular undersampling resulting from simulated cardiac gating. Research supported by the National Heart, Lung, and Blood Institute of the NIH under award number R01HL084022. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.« less

  17. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

    PubMed

    Hsieh, Chen-Ping; Hsieh, Ming-Ju; Fang, Hsin-Yueh; Chao, Yin-Kai

    2017-05-01

    The intraoperative identification of small pulmonary nodules through video-assisted thoracoscopic surgery remains challenging. Although preoperative CT-guided nodule localization is commonly used to detect tumors during video-assisted thoracoscopic surgery (VATS), this approach carries inherent risks. We report the case of a patient with stage I lung cancer presenting as an area of ground-glass opacity (GGO) in the right upper pulmonary lobe. He successfully underwent a single-stage, CT-guided localization and removal of the pulmonary nodule within a hybrid operating room (OR) equipped with a robotic C-arm.

  18. A model for filtered backprojection reconstruction artifacts due to time-varying attenuation values in perfusion C-arm CT.

    PubMed

    Fieselmann, Andreas; Dennerlein, Frank; Deuerling-Zheng, Yu; Boese, Jan; Fahrig, Rebecca; Hornegger, Joachim

    2011-06-21

    Filtered backprojection is the basis for many CT reconstruction tasks. It assumes constant attenuation values of the object during the acquisition of the projection data. Reconstruction artifacts can arise if this assumption is violated. For example, contrast flow in perfusion imaging with C-arm CT systems, which have acquisition times of several seconds per C-arm rotation, can cause this violation. In this paper, we derived and validated a novel spatio-temporal model to describe these kinds of artifacts. The model separates the temporal dynamics due to contrast flow from the scan and reconstruction parameters. We introduced derivative-weighted point spread functions to describe the spatial spread of the artifacts. The model allows prediction of reconstruction artifacts for given temporal dynamics of the attenuation values. Furthermore, it can be used to systematically investigate the influence of different reconstruction parameters on the artifacts. We have shown that with optimized redundancy weighting function parameters the spatial spread of the artifacts around a typical arterial vessel can be reduced by about 70%. Finally, an inversion of our model could be used as the basis for novel dynamic reconstruction algorithms that further minimize these artifacts.

  19. Contrast-Enhanced Abdominal Angiographic CT for Intra-abdominal Tumor Embolization: A New Tool for Vessel and Soft Tissue Visualization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Bernhard Christian, E-mail: bernhard.meyer@charite.de; Frericks, Bernd Benedikt; Albrecht, Thomas

    2007-07-15

    C-Arm cone-beam computed tomography (CACT), is a relatively new technique that uses data acquired with a flat-panel detector C-arm angiography system during an interventional procedure to reconstruct CT-like images. The purpose of this Technical Note is to present the technique, feasibility, and added value of CACT in five patients who underwent abdominal transarterial chemoembolization procedures. Target organs for the chemoembolizations were kidney, liver, and pancreas and a liposarcoma infiltrating the duodenum. The time for patient positioning, C-arm and system preparation, CACT raw data acquisition, and data reconstruction for a single CACT study ranged from 6 to 12 min. The volumemore » data set produced by the workstation was interactively reformatted using maximum intensity projections and multiplanar reconstructions. As part of an angiography system CACT provided essential information on vascular anatomy, therapy endpoints, and immediate follow-up during and immediately after the abdominal interventions without patient transfer. The quality of CACT images was sufficient to influence the course of treatment. This technology has the potential to expedite any interventional procedure that requires three-dimensional information and navigation.« less

  20. Breathing motion compensated reconstruction for C-arm cone beam CT imaging: initial experience based on animal data

    NASA Astrophysics Data System (ADS)

    Schäfer, D.; Lin, M.; Rao, P. P.; Loffroy, R.; Liapi, E.; Noordhoek, N.; Eshuis, P.; Radaelli, A.; Grass, M.; Geschwind, J.-F. H.

    2012-03-01

    C-arm based tomographic 3D imaging is applied in an increasing number of minimal invasive procedures. Due to the limited acquisition speed for a complete projection data set required for tomographic reconstruction, breathing motion is a potential source of artifacts. This is the case for patients who cannot comply breathing commands (e.g. due to anesthesia). Intra-scan motion estimation and compensation is required. Here, a scheme for projection based local breathing motion estimation is combined with an anatomy adapted interpolation strategy and subsequent motion compensated filtered back projection. The breathing motion vector is measured as a displacement vector on the projections of a tomographic short scan acquisition using the diaphragm as a landmark. Scaling of the displacement to the acquisition iso-center and anatomy adapted volumetric motion vector field interpolation delivers a 3D motion vector per voxel. Motion compensated filtered back projection incorporates this motion vector field in the image reconstruction process. This approach is applied in animal experiments on a flat panel C-arm system delivering improved image quality (lower artifact levels, improved tumor delineation) in 3D liver tumor imaging.

  1. Prostate Brachytherapy Seed Reconstruction with Gaussian Blurring and Optimal Coverage Cost

    PubMed Central

    Lee, Junghoon; Liu, Xiaofeng; Jain, Ameet K.; Song, Danny Y.; Burdette, E. Clif; Prince, Jerry L.; Fichtinger, Gabor

    2009-01-01

    Intraoperative dosimetry in prostate brachytherapy requires localization of the implanted radioactive seeds. A tomosynthesis-based seed reconstruction method is proposed. A three-dimensional volume is reconstructed from Gaussian-blurred projection images and candidate seed locations are computed from the reconstructed volume. A false positive seed removal process, formulated as an optimal coverage problem, iteratively removes “ghost” seeds that are created by tomosynthesis reconstruction. In an effort to minimize pose errors that are common in conventional C-arms, initial pose parameter estimates are iteratively corrected by using the detected candidate seeds as fiducials, which automatically “focuses” the collected images and improves successive reconstructed volumes. Simulation results imply that the implanted seed locations can be estimated with a detection rate of ≥ 97.9% and ≥ 99.3% from three and four images, respectively, when the C-arm is calibrated and the pose of the C-arm is known. The algorithm was also validated on phantom data sets successfully localizing the implanted seeds from four or five images. In a Phase-1 clinical trial, we were able to localize the implanted seeds from five intraoperative fluoroscopy images with 98.8% (STD=1.6) overall detection rate. PMID:19605321

  2. Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitrović, Uroš; Pernuš, Franjo; Likar, Boštjan

    Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3Dmore » image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and template matching and final registration involving C-arm calibration were 36%, 73%, and 93%, respectively, while registration accuracy of 0.59 mm was the best after final registration. By compensating in-plane translation errors by initial template matching, the success rates achieved after the final stage improved consistently for all methods, especially if C-arm calibration was performed simultaneously with the 3D–2D image registration. Conclusions: Because the tested methods perform simultaneous C-arm calibration and 3D–2D registration based solely on anatomical information, they have a high potential for automation and thus for an immediate integration into current interventional workflow. One of the authors’ main contributions is also comprehensive and representative validation performed under realistic conditions as encountered during cerebral EIGI.« less

  3. Theoretical and experimental analysis of the electromechanical behavior of a compact spherical loudspeaker array for directivity control.

    PubMed

    Pasqual, Alexander Mattioli; Herzog, Philippe; Arruda, José Roberto de França

    2010-12-01

    Sound directivity control is made possible by a compact array of independent loudspeakers operating at the same frequency range. The drivers are usually distributed over a sphere-like frame according to a Platonic solid geometry to obtain a highly symmetrical configuration. The radiation pattern of spherical loudspeaker arrays has been predicted from the surface velocity pattern by approximating the drivers membranes as rigid vibrating spherical caps, although a rigorous assessment of this model has not been provided so far. Many aspects concerning compact array electromechanics remain unclear, such as the effects on the acoustical performance of the drivers interaction inside the array cavity, or the fact that voltages rather than velocities are controlled in practice. This work presents a detailed investigation of the electromechanical behavior of spherical loudspeaker arrays. Simulation results are shown to agree with laser vibrometer measurements and experimental sound power data obtained for a 12-driver spherical array prototype at low frequencies, whereas the non-rigid body motion and the first cavity eigenfrequency yield a discrepancy between theoretical and experimental results at high frequencies. Finally, although the internal acoustic coupling affects the drivers vibration in the low-frequency range, it does not play an important role on the radiated sound power.

  4. The Effect of Low-Frequency Road Noise on Driver Sleepiness and Performance

    PubMed Central

    Anund, Anna; Lahti, Eva; Fors, Carina; Genell, Anders

    2015-01-01

    It is a well-known fact today that driver sleepiness is a contributory factor in crashes. Factors considered as sleepiness contributor are mostly related to time of the day, hours being awake and hours slept. Factors contributing to active and passive fatigue are mostly focusing on the level of cognitive load. Less is known what role external factors, e.g. type of road, sound/noise, vibrations etc., have on the ability to stay awake both under conditions of sleepiness and under active or passive fatigue. The aim of this moving base driving simulator study with 19 drivers participating in a random order day and night time, was to evaluate the effect of low-frequency road noise on driver sleepiness and performance, including both long-term and short-term effects. The results support to some extent the hypothesis that road-induced interior vehicle sound affects driving performance and driver sleepiness. Increased low-frequency noise helps to reduce speed during both day- and night time driving, but also contributes to increase the number of lane crossings during night time. PMID:25874883

  5. The effect of low-frequency road noise on driver sleepiness and performance.

    PubMed

    Anund, Anna; Lahti, Eva; Fors, Carina; Genell, Anders

    2015-01-01

    It is a well-known fact today that driver sleepiness is a contributory factor in crashes. Factors considered as sleepiness contributor are mostly related to time of the day, hours being awake and hours slept. Factors contributing to active and passive fatigue are mostly focusing on the level of cognitive load. Less is known what role external factors, e.g. type of road, sound/noise, vibrations etc., have on the ability to stay awake both under conditions of sleepiness and under active or passive fatigue. The aim of this moving base driving simulator study with 19 drivers participating in a random order day and night time, was to evaluate the effect of low-frequency road noise on driver sleepiness and performance, including both long-term and short-term effects. The results support to some extent the hypothesis that road-induced interior vehicle sound affects driving performance and driver sleepiness. Increased low-frequency noise helps to reduce speed during both day- and night time driving, but also contributes to increase the number of lane crossings during night time.

  6. Descriptive analysis of combine cabin vibrations and their effect on the human body

    NASA Astrophysics Data System (ADS)

    Hostens, I.; Ramon, H.

    2003-09-01

    All on- and off-road vehicles are exposed to vibrations caused by unevenness of road or soil profile, moving elements within the machine or implements. A higher prevalence of low back pain is found in drivers of off-road machinery than in other drivers. In this study, significantly higher levels of low-frequency vibrations are found in the cabin of a combine, driving at high speed (20 km/h) on a concrete surface, compared to driving slower on field road. Comfort values indicate that injury can result from long-term driving on the field as well as on a concrete road. As seats with suspension systems are the main transmission paths of vibration towards the spine of the driver, their vibration attenuating characteristics play an important role in comfort assessment. The resonant frequency of seats with passive suspension system, used in agricultural machinery, lies in the low-frequency range most excited in agricultural machinery. A seat with air suspension is found to attenuate better frequencies above 4 Hz and provide more comfort to the driver than a seat with a mechanical suspension.

  7. Incidence and pattern of traumatic spinal fractures and associated spinal cord injury resulting from motor vehicle collisions in China over 11 years: An observational study.

    PubMed

    Wang, Hongwei; Liu, Xinwei; Zhao, Yiwen; Ou, Lan; Zhou, Yue; Li, Changqing; Liu, Jun; Chen, Yu; Yu, Hailong; Wang, Qi; Han, Jianda; Xiang, Liangbi

    2016-10-01

    To investigate the incidence and pattern of traumatic spinal fractures (TSFs) and associated spinal cord injury (SCI) resulting from motor vehicle collisions (MVCs).This was a cross-sectional study. We retrospectively reviewed 698 patients with TSFs resulting from MVCs admitted to our university-affiliated hospitals from 2001 to 2011. The incidence and pattern were summarized with respect to different age groups, fracture levels, and the role of patients.There were 464 males (66.5%) and 234 females (33.5%) aged 40.5 ± 13.8 years old. The most common roles of patients in MVCs were car drivers (189, 27.1%), pedestrians hurt by a car (155, 22.2%), and car passengers (145, 20.8%). The most common fracture levels were L1 (n = 198, 19.2%) and T12 (n = 116, 11.3%), followed by C2 (n = 86, 8.3%). A total of 298 (42.7%) patients suffered a spinal cord injury. The frequencies of SCIs decreased from 53.1% to 24.6% with increasing age. The patients in the 20 to 39 age group (45.3% of all patients) had the largest sex ratio (2.4) and highest frequency of complete SCIs (19.3%) and complications (3.2%). Motorcycle drivers had the youngest mean age (35.7 ± 10.2), largest sex ratio (10.4), and highest frequency of SCIs (56.0%) and complications (4.4%). Motorcycle passengers had the highest frequency of complete SCI (22.7%) and ASOIs (45.5%) and the largest mean injury severity scoring (ISS) (18.9 ± 9.6). The most common fracture levels of motorcycle drivers were C3-C7, while that of others were T11-L2.The most common role of patients who sustained TSFs were car drivers who were 20 to 39 years old. Motorcycle drivers had the highest frequency of SCIs and complications. Motorcycle passengers had the highest frequency of complete SCIs and ASOIs and the largest ISS. Therefore, we should pay more attention to MVC patients, especially car drivers and motorcycle drivers and passengers.

  8. The relative frequency of unsafe driving acts in serious traffic crashes

    DOT National Transportation Integrated Search

    2001-01-01

    This study was conducted to determine the specific driver behaviors and unsafe driving acts that lead to crashes, and the situational, driver and vehicle characteristics associated with these behaviors. A sample of 723 crashes involving 1284 drivers ...

  9. Toward understanding on-road interactions between male and female drivers.

    DOT National Transportation Integrated Search

    2011-01-01

    This study examined gender effects in six geometric scenarios of two-vehicle crashes in : which an involved driver could potentially ascertain the gender of the other driver prior to the : crash. The actual frequencies of different combinations of th...

  10. Quality engineering tools focused on high power LED driver design using boost power stages in switch mode

    NASA Astrophysics Data System (ADS)

    Ileana, Ioan; Risteiu, Mircea; Marc, Gheorghe

    2016-12-01

    This paper is a part of our research dedicated to high power LED lamps designing. The boost-up selected technology wants to meet driver producers' tendency in the frame of efficiency and disturbances constrains. In our work we used modeling and simulation tools for implementing scenarios of the driver work when some controlling functions are executed (output voltage/ current versus input voltage and fixed switching frequency, input and output electric power transfer versus switching frequency, transient inductor voltage analysis, and transient out capacitor analysis). Some electrical and thermal stress conditions are also analyzed. Based on these aspects, a high reliable power LED driver has been designed.

  11. Chromosomal aberrations in peripheral lymphocytes of train engine drivers.

    PubMed

    Nordenson, I; Mild, K H; Järventaus, H; Hirvonen, A; Sandström, M; Wilén, J; Blix, N; Norppa, H

    2001-07-01

    Studies of Swedish railway employees have indicated that railroad engine drivers have an increased cancer morbidity and incidence of chronic lymphatic leukemia. The drivers are exposed to relatively high magnetic fields (MF), ranging from a few to over a hundred microT. Although the possible genotoxic potential of MF is unclear, some earlier studies have indicated that occupational exposure to MF may increase chromosome aberrations in blood lymphocytes. Since an increased level of chromosomal aberrations has been suggested to predict elevated cancer risk, we performed a cytogenetic analysis on cultured (48 h) peripheral lymphocytes of Swedish train engine drivers. A pilot study of 18 engine drivers indicated a significant difference in the frequency of cells with chromosomal aberrations (gaps included or excluded) in comparison with seven concurrent referents (train dispatchers) and a control group of 16 office workers. The engine drivers had about four times higher frequency of cells with chromosome-type aberrations (excluding gaps) than the office workers (P < 0.01) and the dispatchers (P < 0.05). Seventy-eight percent of the engine drivers showed at least one cell per 100 with chromosome-type aberrations compared with 29% among the dispatchers and 31% among the office workers. In a follow-up study, another 30 engine drivers showed an increase (P < 0.05) in the frequency of cells with chromosome-type aberrations (gaps excluded) as compared with 30 referent policemen. Sixty percent of the engine drivers had one or more cells (per 100 cells) with chromosome-type aberrations compared with 30% among the policemen. In conclusion, the results of the two studies support the hypothesis that exposure to MF at mean intensities of 2-15 microT can induce chromosomal damage. Copyright 2001 Wiley-Liss, Inc.

  12. National reported patterns of driver cell phone use in the United States.

    PubMed

    Braitman, Keli A; McCartt, Anne T

    2010-12-01

    To obtain detailed information on patterns of driver cell phone use, including how often drivers talk and text, the extent to which they use hands-free devices, and knowledge of and reaction to state cell phone laws. Telephone surveys were conducted with 1219 drivers in the 48 contiguous U.S. states and the District of Columbia, using random samples of landline and cell phone numbers. Forty percent of drivers reported talking on phones at least a few times per week. The percentages were highest for males (49%) and drivers ages 25-29 (66%). The percentage of drivers who reported never talking on phones was higher in states with all-driver bans on handheld phone use (44%) than in states without a ban applying to all drivers (30%). The percentage of drivers who talk on phones and always talk hands-free was higher in states with all-driver handheld phone bans (22%) than where such bans are not in effect (13%). Thirteen percent of drivers reported some texting while driving, and this percentage was highest among drivers ages 18-24 (43%). Twelve percent of drivers in states with all-driver texting bans reported texting while driving, compared with 14 percent in states with no texting ban. Among drivers ages 18-24, the percentages were 45 and 48 percent, respectively. Most drivers reported talking on phones while driving, even though earlier surveys have found that most people think this behavior should be banned. Fewer drivers overall reported texting, but the frequency of texting was higher among young drivers. Laws banning handheld phone use seem to discourage some drivers from talking on any type of phone and motivate some drivers to talk hands-free. Laws banning texting while driving have little effect on the reported frequency of texting while driving in any age group.

  13. Assessment of driver inexperience with an automobile as a factor which contributes to highway accidents

    DOT National Transportation Integrated Search

    1984-12-01

    This study addresses the statistical relationship between driver familiarity with : vehicles and accident frequency. In 1981, 8.9 percent of all drivers in NASS-reported : automobile accidents had less than 150 miles driving experience with the accid...

  14. A simple wave driver

    NASA Astrophysics Data System (ADS)

    Kağan Temiz, Burak; Yavuz, Ahmet

    2015-08-01

    This study was done to develop a simple and inexpensive wave driver that can be used in experiments on string waves. The wave driver was made using a battery-operated toy car, and the apparatus can be used to produce string waves at a fixed frequency. The working principle of the apparatus is as follows: shortly after the car is turned on, the wheel starts to turn at a constant angular speed. A rod that is fixed on the wheel turns at the same constant angular speed, too. A tight string that the wave will be created on is placed at a distance where the rod can touch the string. During each rotation of the wheel, the rod vibrates the string up and down. The vibration frequency of this rod equals the wheel’s rotation frequency, and this frequency value can be measured easily with a small magnet and a bicycle speedometer. In this way, the frequency of the waves formed in the rope can also be measured.

  15. C-arm Cone Beam Computed Tomography: A New Tool in the Interventional Suite.

    PubMed

    Raj, Santhosh; Irani, Farah Gillan; Tay, Kiang Hiong; Tan, Bien Soo

    2013-11-01

    C-arm Cone Beam CT (CBCT) is a technology that is being integrated into many of the newer angiography systems in the interventional suite. Due to its ability to provide cross sectional imaging, it has opened a myriad of opportunities for creating new clinical applications. We review the technical aspects, current reported clinical applications and potential benefits of this technology. Searches were made via PubMed using the string "CBCT", "Cone Beam CT", "Cone Beam Computed Tomography" and "C-arm Cone Beam Computed Tomography". All relevant articles in the results were reviewed. CBCT clinical applications have been reported in both vascular and non-vascular interventions. They encompass many aspects of a procedure including preprocedural planning, intraprocedural guidance and postprocedural assessment. As a result, they have allowed the interventionalist to be safer and more accurate in performing image guided procedures. There are however several technical limitations. The quality of images produced is not comparable to conventional computed tomography (CT). Radiation doses are also difficult to quantify when compared to CT and fluoroscopy. CBCT technology in the interventional suite has contributed significant benefits to the patient despite its current limitations. It is a tool that will evolve and potentially become an integral part of imaging guidance for intervention.

  16. C-Arm Cone-Beam CT-Guided Transthoracic Lung Core Needle Biopsy as a Standard Diagnostic Tool

    PubMed Central

    Jaconi, Marta; Pagni, Fabio; Vacirca, Francesco; Leni, Davide; Corso, Rocco; Cortinovis, Diego; Bidoli, Paolo; Bono, Francesca; Cuttin, Maria S.; Valente, Maria G.; Pesci, Alberto; Bedini, Vittorio A.; Leone, Biagio E.

    2015-01-01

    Abstract C-arm cone-beam computed tomography (CT)-guided transthoracic lung core needle biopsy (CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. This article will focus on the clinical features related to CNB in terms of diagnostic performance and complication rate. Moreover, the concept of categorizing pathological diagnosis into 4 categories, which could be used for clinical management, follow-up, and quality assurance is also introduced. We retrospectively collected data regarding 375 C-arm cone-beam CT-guided CNBs from January 2010 and June 2014. Clinical and radiological variables were evaluated in terms of success or failure rate. Pathological reports were inserted in 4 homogenous groups (nondiagnostic-L1, benign-L2, malignant not otherwise specified-L3, and malignant with specific histotype-L4), defining for each category a hierarchy of suggested actions. The sensitivity, specificity, and positive and negative predictive value and accuracy for patients subjected to CNBs were of 96.8%, 100%, 100%, 100%, and 97.2%, respectively. Roughly 75% of our samples were diagnosed as malignant, with 60% lung adenocarcinoma diagnoses. Molecular analyses were performed on 85 malignant samples to verify applicability of targeted therapy. The rate of “nondiagnostic” samples was 12%. C-arm cone-beam CT-guided transthoracic lung CNB can represent the gold standard for the diagnostic evaluation of pulmonary nodules. A clinical and pathological multidisciplinary evaluation of CNBs was needed in terms of integration of radiological, histological, and oncological data. This approach provided exceptional performances in terms of specificity, positive and negative predictive values; sensitivity in our series was lower compared with other large studies, probably due to the application of strong criteria of adequacy for CNBs (L1 class rate). The satisfactory rate of collected material was evaluated not only in terms of merely diagnostic performances but also for predictive results by molecular analysis. PMID:25816042

  17. SU-C-207-02: A Method to Estimate the Average Planar Dose From a C-Arm CBCT Acquisition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Supanich, MP

    2015-06-15

    Purpose: The planar average dose in a C-arm Cone Beam CT (CBCT) acquisition had been estimated in the past by averaging the four peripheral dose measurements in a CTDI phantom and then using the standard 2/3rds peripheral and 1/3 central CTDIw method (hereafter referred to as Dw). The accuracy of this assumption has not been investigated and the purpose of this work is to test the presumed relationship. Methods: Dose measurements were made in the central plane of two consecutively placed 16cm CTDI phantoms using a 0.6cc ionization chamber at each of the 4 peripheral dose bores and in themore » central dose bore for a C-arm CBCT protocol. The same setup was scanned with a circular cut-out of radiosensitive gafchromic film positioned between the two phantoms to capture the planar dose distribution. Calibration curves for color pixel value after scanning were generated from film strips irradiated at different known dose levels. The planar average dose for red and green pixel values was calculated by summing the dose values in the irradiated circular film cut out. Dw was calculated using the ionization chamber measurements and film dose values at the location of each of the dose bores. Results: The planar average dose using both the red and green pixel color calibration curves were within 10% agreement of the planar average dose estimated using the Dw method of film dose values at the bore locations. Additionally, an average of the planar average doses calculated using the red and green calibration curves differed from the ionization chamber Dw estimate by only 5%. Conclusion: The method of calculating the planar average dose at the central plane of a C-arm CBCT non-360 rotation by calculating Dw from peripheral and central dose bore measurements is a reasonable approach to estimating the planar average dose. Research Grant, Siemens AG.« less

  18. Comparison of image quality and radiation exposure from C-arm fluoroscopes when used for imaging the spine.

    PubMed

    Prasarn, Mark L; Coyne, Ellen; Schreck, Michael; Rodgers, Jamie D; Rechtine, Glenn R

    2013-07-15

    Cadaveric imaging study. We sought to compare the fluoroscopic images produced by 4 different fluoroscopes for image quality and radiation exposure when used for imaging the spine. There are no previous published studies comparing mobile C-arm machines commonly used in clinical practice for imaging the spine. Anterior-posterior and lateral images of the cervical, thoracic, and lumbar spine were obtained from a cadaver placed supine on a radiolucent table. The fluoroscopy units used for the study included (1) GE OEC 9900 Elite (2010 model; General Electric Healthcare, Waukesha, WI), (2) Philips BV Pulsera (2009 model; Philips Healthcare, Andover, MA), (3) Philips BV Pulsera (2010 model; Philips Healthcare, Andover, MA), and (4) Siemens Arcadis Avantic (2010 model; Siemens Medical Solutions, Malvern, PA). The images were then downloaded, placed into a randomizer program, and evaluated by a group of spine surgeons and neuroradiologists independently. The reviewers, who were blinded to the fluoroscope the images were from, ranked them from best to worst using a numeric system. In addition, the images were rated according to a quality scale from 1 to 5, with 1 representing the best image quality. The radiation exposure level for the fluoroscopy units was also compared and was based on energy emission. According to the mean values for rank, the following order of best to worst was observed: (1) GE OEC > (2) Philips 2010 > (3) Philips 2009 > (4) Siemans. The exact same order was found when examining the image quality ratings. When comparing the radiation exposure level difference, it was observed that the OEC was the lowest, and there was a minimum 30% decrease in energy emission from the OEC versus the other C-arms studied. This is the first time that the spine image quality and radiation exposure of commonly used C-arm machines have been compared. The OEC was ranked the best, produced the best quality images, and had the least amount of radiation.

  19. Decreased Radiation Exposure Among Orthopedic Residents Is Maintained When Using the Mini C-Arm After Undergoing Radiation Safety Training.

    PubMed

    Gendelberg, David; Hennrikus, William L; Sawyer, Carissa; Armstrong, Douglas; King, Steven

    2017-09-01

    The resident curriculum of the American Board of Orthopaedic Surgery emphasizes radiation safety. Gendelberg showed that, immediately after a program on fluoroscopic safety, residents used less radiation when using the mini C-arm to reduce pediatric fractures. The current study evaluated whether this effect lasted. Residents underwent a new annual 3-hour session on mini C-arm use and radiation. Group A included 53 reductions performed before training. Group B included 45 reductions performed immediately after training. Group C included 46 reductions performed 11 months later. For distal radius fractures, exposure time and amount were 38.1 seconds and 83.1 mR, respectively, for group A; 26.7 seconds and 32.6 mR, respectively, for group B; and 24.1 seconds and 40.0 mR, respectively, for group C. When radiation time and amount were compared between group B and group C, P values were .525 and .293, respectively. When group C and group A were compared, P values were <.05 and <.01, respectively. For both bone forearm fractures, exposure time and amount were 41.2 seconds and 90.9 mR, respectively, for group A; 28.9 seconds and 30.4 mR, respectively, for group B; and 31.2 seconds and 43.6 mR, respectively, for group C. When radiation time and amount were compared between group B and group C, P values were .704 and .117, respectively. When group C and group A were compared, P values were .183 and .004, respectively. No significant difference in radiation exposure was noted immediately after training vs 11 months later. A sustained decrease in radiation exposure occurred after an educational program on safe mini C-arm use. [Orthopedics. 2017; 40(5):e788-e792.]. Copyright 2017, SLACK Incorporated.

  20. C-arm cone-beam CT-guided transthoracic lung core needle biopsy as a standard diagnostic tool: an observational study.

    PubMed

    Jaconi, Marta; Pagni, Fabio; Vacirca, Francesco; Leni, Davide; Corso, Rocco; Cortinovis, Diego; Bidoli, Paolo; Bono, Francesca; Cuttin, Maria S; Valente, Maria G; Pesci, Alberto; Bedini, Vittorio A; Leone, Biagio E

    2015-03-01

    C-arm cone-beam computed tomography (CT)-guided transthoracic lung core needle biopsy (CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. This article will focus on the clinical features related to CNB in terms of diagnostic performance and complication rate. Moreover, the concept of categorizing pathological diagnosis into 4 categories, which could be used for clinical management, follow-up, and quality assurance is also introduced. We retrospectively collected data regarding 375 C-arm cone-beam CT-guided CNBs from January 2010 and June 2014. Clinical and radiological variables were evaluated in terms of success or failure rate. Pathological reports were inserted in 4 homogenous groups (nondiagnostic--L1, benign--L2, malignant not otherwise specified--L3, and malignant with specific histotype--L4), defining for each category a hierarchy of suggested actions. The sensitivity, specificity, and positive and negative predictive value and accuracy for patients subjected to CNBs were of 96.8%, 100%, 100%, 100%, and 97.2%, respectively. Roughly 75% of our samples were diagnosed as malignant, with 60% lung adenocarcinoma diagnoses. Molecular analyses were performed on 85 malignant samples to verify applicability of targeted therapy. The rate of "nondiagnostic" samples was 12%. C-arm cone-beam CT-guided transthoracic lung CNB can represent the gold standard for the diagnostic evaluation of pulmonary nodules. A clinical and pathological multidisciplinary evaluation of CNBs was needed in terms of integration of radiological, histological, and oncological data. This approach provided exceptional performances in terms of specificity, positive and negative predictive values; sensitivity in our series was lower compared with other large studies, probably due to the application of strong criteria of adequacy for CNBs (L1 class rate). The satisfactory rate of collected material was evaluated not only in terms of merely diagnostic performances but also for predictive results by molecular analysis.

  1. Pre-operative Simulation of the Appropriate C-arm Position Using Computed Tomography Post-processing Software Reduces Radiation and Contrast Medium Exposure During EVAR Procedures.

    PubMed

    Stahlberg, E; Planert, M; Panagiotopoulos, N; Horn, M; Wiedner, M; Kleemann, M; Barkhausen, J; Goltz, J P

    2017-02-01

    The aim was to evaluate the feasibility and efficacy of a new method for pre-operative calculation of an appropriate C-arm position for iliac bifurcation visualisation during endovascular aortic repair (EVAR) procedures by using three dimensional computed tomography angiography (CTA) post-processing software. Post-processing software was used to simulate C-arm angulations in two dimensions (oblique, cranial/caudal) for appropriate visualisation of distal landing zones at the iliac bifurcation during EVAR. Retrospectively, 27 consecutive EVAR patients (25 men, mean ± SD age 73 ± 7 years) were identified; one group of patients (NEW; n = 12 [23 iliac bifurcations]) was compared after implementation of the new method with a group of patients who received a historic method (OLD; n = 15 [23 iliac bifurcations]), treated with EVAR before the method was applied. In the OLD group, a median of 2.0 (interquartile range [IQR] 1-3) digital subtraction angiography runs were needed per iliac bifurcation versus 1.0 (IQR 1-1) runs in the NEW group (p = .007). The median dose area products per iliac bifurcation were 11951 mGy*cm 2 (IQR 7308-16663 mGy*cm 2 ) for the NEW, and 39394 mGy*cm 2 (IQR 19066-53702 mGy*cm 2 ) for the OLD group, respectively (p = .001). The median volume of contrast per iliac bifurcation was 13.0 mL (IQR: 13-13 mL) in the NEW and 26 mL (IQR 13-39 mL) in the OLD group (p = .007). Pre-operative simulation of the appropriate C-arm angulation in two dimensions using dedicated computed tomography angiography post-processing software is feasible and significantly reduces radiation and contrast medium exposure. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. WE-EF-207-02: The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritschl, L; Kachelriess, M; Kuntz, J

    Purpose: The proposed method enables the acquisition of a complete dataset for 3D reconstruction of C-Arm data using less than 180° rotation. Methods: Typically a C–arm cone–beam CT scan is performed using a circle–like trajectory around a region of interest. Therefore an angular range of at least 180° plus fan–angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C–arm system, for example a larger C radius or a smaller C opening respectively. This is even more important for mobile C-arm devices which are typically usedmore » in surgical applications.To overcome these limitations we propose a new trajectory which requires only 180° minusfan–angle of rotation for a complete data set. The trajectory consists of three parts: A rotation of the C around a defined iso–center and two translational movements parallel to the detector plane at the begin and at the end of the rotation (rotate plus shift trajectory). This enables the acquisition of a completely sampled dataset using only 180° minus fan–angle of rotation. Results: For the evaluation of the method we show simulated and measured data. The results show, that the rotate plus shift scan yields equivalent image quality compared to the short scan which is assumed to be the gold standard for C-arm CT today. Compared to the pure rotational scan over only 165°, the rotate plus shift scan shows strong improvements in image quality. Conclusion: The proposed method makes 3D imaging using C–arms with less than 180° rotation range possible. This enables integrating full 3D functionality into a C- arm device without any loss of handling and usability for 2D imaging.« less

  3. Using event-triggered naturalistic data to examine the prevalence of teen driver distractions in rear-end crashes.

    PubMed

    Carney, Cher; Harland, Karisa K; McGehee, Daniel V

    2016-06-01

    While teen driver distraction is cited as a leading cause of crashes, especially rear-end crashes, little information is available regarding its true prevalence. The majority of distraction studies rely on data derived from police reports, which provide limited information regarding driver distraction. This study examined over 400 teen driver rear-end crashes captured by in-vehicle event recorders. A secondary data analysis was conducted, paying specific attention to driver behaviors, eyes-off-road time, and response times to lead-vehicle braking. Among teens in moderate to severe rear-end crashes, over 75% of drivers were observed engaging in a potentially distracting behavior. The most frequently seen driver behaviors were cell phone use, attending to a location outside the vehicle, and attending to passengers. Drivers using a cell phone had a significantly longer response time than drivers not engaged in any behaviors, while those attending to passengers did not. Additionally, in about 50% of the rear-end crashes where the driver was operating/looking at a phone (e.g., texting), the driver showed no driver response (i.e., braking or steering input) before impact, compared to 10% of crashes where the driver was attending to a passenger. The high frequency of attending to passengers and use of a cell phone leading up to a crash, compounded with the associated risks, underlines the importance of continued investigation in these areas. Parents and teens must be educated regarding the frequency of and the potential effects of distractions. Additional enforcement may be necessary if Graduated Driver Licensing (GDL) programs are to be effective. Systems that alert distracted teens could also be especially helpful in reducing rear-end collisions. Copyright © 2016 Elsevier Ltd and National Safety Council. All rights reserved.

  4. Mobile phone use while driving in a sample of Spanish university workers.

    PubMed

    Gras, M Eugenia; Cunill, Monica; Sullman, Mark J M; Planes, Montserrat; Aymerich, Maria; Font-Mayolas, Silvia

    2007-03-01

    A number of epidemiological studies have reported drivers who use a mobile phone while driving have an elevated risk of being involved in a crash. This is particularly concerning as a survey of drivers in the Spanish region of Catalunya found that approximately 87% own mobile phones. The present study investigated the reported frequency of mobile phone use on Spanish roads (for talking and using SMS), the characteristics of the drivers who use mobile phones while driving and whether they altered their driving behaviour when using a mobile phone. The research found that more than 60% use a mobile phone while driving and that the phone is mostly used for making calls, rather than using SMS. In general, males and females use mobile phones about the same reported frequency, although males were more likely to use a mobile phone to talk on the highway. The pattern for age was the same for both male and female participants, with the younger drivers using SMS more frequently than older drivers. On urban roads almost half of the drivers reported changing their driving behaviour when using a mobile phone, while on the highway this figure was slightly over 41%. The reported frequency of using a mobile phone to talk on urban roads was significantly correlated with crash involvement. However, this affect disappeared once the contributions of the demographic and descriptive variables had been partialled out.

  5. Diabetic Driving Studies-Part 2: A Comparison of Brake Response Time Between Drivers With Diabetes With and Without Lower Extremity Sensorimotor Neuropathy.

    PubMed

    Spiess, Kerianne E; Sansosti, Laura E; Meyr, Andrew J

    We have previously demonstrated an abnormally delayed mean brake response time and an increased frequency of abnormally delayed brake responses in a group of neuropathic drivers with diabetes compared with a control group of drivers with neither diabetes nor lower extremity neuropathy. The objective of the present case-control study was to compare the mean brake response time between 2 groups of drivers with diabetes with and without lower extremity sensorimotor neuropathy. The braking performances of the participants were evaluated using a computerized driving simulator with specific measurement of the mean brake response time and the frequency of the abnormally delayed brake responses. We compared a control group of 25 active drivers with type 2 diabetes without lower extremity neuropathy and an experimental group of 25 active drivers with type 2 diabetes and lower extremity neuropathy from an urban U.S. podiatric medical clinic. The experimental group demonstrated an 11.49% slower mean brake response time (0.757 ± 0.180 versus 0.679 ± 0.120 second; p < .001), with abnormally delayed reactions occurring at a greater frequency (57.5% versus 35.0%; p < .001). Independent of a comparative statistical analysis, diabetic drivers with neuropathy demonstrated a mean brake response time slower than a suggested safety threshold of 0.70 second, and diabetic drivers without neuropathy demonstrated a mean brake response time faster than this threshold. The results of the present investigation provide evidence that the specific onset of lower extremity sensorimotor neuropathy associated with diabetes appears to impart a negative effect on automobile brake responses. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Present developments and status of electron sources for high power gyrotron tubes and free electron masers

    NASA Astrophysics Data System (ADS)

    Thumm, M.

    1997-02-01

    Gyrotron oscillators are mainly used as high power mm-wave sources for start-up, electron cyclotron heating (ECH) and diagnostics of magnetically confined plasmas for controlled thermonuclear fusion research. 140 GHz (110 GHz) gyrotrons with output power Pout = 0.55 MW (0.93 MW), pulse length τ = 3.0 s (2.0 s) and efficiency η = 40% (38%) are commercially available. Total efficiencies around 50% have been achieved using single-stage depressed collectors. Diagnostic gyrotrons deliver Pout = 40 kW with τ = 40 μs at frequencies up to 650 GHz ( η≥4%). Recently, gyrotron oscillators have also been successfully used in materials processing, for example sintering of high performance, structural and functional ceramics. Such technological applications require gyrotrons with f≥24 GHz, Pout = 10-100 kW, CW, η≥30%. This paper reports on recent achievements in the development of very high power mm-wave gyrotron oscillators for long pulse or CW operation. In addition a short overview of the present development status of gyrotrons for technological applications, gyroklystron amplifiers, gyro-TWT amplifiers, cyclotron autoresonance masers (CARMs) and free electron masers (FEMs) is given. The most impressive FEM output parameters are: Pout = 2GW, τ = 20 ns, η = 13% at 140 GHz (LLNL) and Pout = 15 kW, τ = 20 μs, η = 5% in the range from 120 to 900 GHz (UCSB). In gyro-devices, magnetron injection guns (MIGs) operating in the temperature limited current regime have thus far been used most successfully. Diode guns as well as triode guns with a modulating anode are employed. Tests of a MIG operated under space-charge limited conditions have been not very successful. Electrostatic CW FEMs are driven by thermionic Pierce guns whereas pulsed high power devices employ many types of accelerators as drivers for example pulse-line accelerators, microtrons and induction or rf linacs, using field and photo emission cathodes.

  7. Closed bore XMR (CBXMR) systems for aortic valve replacement: Investigation of rotating-anode x-ray tube heat loadability

    PubMed Central

    Bracken, John A.; Lillaney, Prasheel V.; Fahrig, Rebecca; Rowlands, J. A.

    2008-01-01

    In order to improve the safety and efficacy of percutaneous aortic valve replacement procedures, a closed bore hybrid x-ray∕MRI (CBXMR) system is proposed in which an x-ray C-arm will be positioned with its isocenter ≈1 m from the entrance of a clinical MRI scanner. This system will harness the complementary strengths of both modalities to improve clinical outcome. A key component of the CBXMR system will be a rotating anode x-ray tube to produce high-quality x-ray images. There are challenges in positioning an x-ray tube in the magnetic fringe field of the MRI magnet. Here, the effects of an external magnetic field on x-ray tube induction motors of radiography x-ray tubes and the corresponding reduction of x-ray tube heat loadability are investigated. Anode rotation frequency fanode was unaffected when the external magnetic field Bb was parallel to the axis of rotation of the anode but decreased when Bb was perpendicular to the axis of rotation. The experimental fanode values agreed with predicted values to within ±3% over a Bb range of 0–30 mT. The MRI fringe field at the proposed location of the x-ray tube mounted on the C-arm (≈4 mT) reduced fanode by only 1%, so x-ray tube heat loadability will not be compromised when using CBXMR systems for percutaneous aortic valve replacement procedures. Eddy current heating power in the rotor due to an MRI fringe field was found to be two orders of magnitude weaker than the heating power produced on the anode due to a fluoroscopic exposure, so eddy current heating had no effect on x-ray tube heat loadability. PMID:18841857

  8. A Pooled Sequencing Approach Identifies a Candidate Meiotic Driver in Drosophila

    PubMed Central

    Wei, Kevin H.-C.; Reddy, Hemakumar M.; Rathnam, Chandramouli; Lee, Jimin; Lin, Deanna; Ji, Shuqing; Mason, James M.; Clark, Andrew G.; Barbash, Daniel A.

    2017-01-01

    Meiotic drive occurs when a selfish element increases its transmission frequency above the Mendelian ratio by hijacking the asymmetric divisions of female meiosis. Meiotic drive causes genomic conflict and potentially has a major impact on genome evolution, but only a few drive loci of large effect have been described. New methods to reliably detect meiotic drive are therefore needed, particularly for discovering moderate-strength drivers that are likely to be more prevalent in natural populations than strong drivers. Here, we report an efficient method that uses sequencing of large pools of backcross (BC1) progeny to test for deviations from Mendelian segregation genome-wide with single-nucleotide polymorphisms (SNPs) that distinguish the parental strains. We show that meiotic drive can be detected by a characteristic pattern of decay in distortion of SNP frequencies, caused by recombination unlinking the driver from distal loci. We further show that control crosses allow allele-frequency distortion caused by meiotic drive to be distinguished from distortion resulting from developmental effects. We used this approach to test whether chromosomes with extreme telomere-length differences segregate at Mendelian ratios, as telomeric regions are a potential hotspot for meiotic drive due to their roles in meiotic segregation and multiple observations of high rates of telomere sequence evolution. Using four different pairings of long and short telomere strains, we find no evidence that extreme telomere-length variation causes meiotic drive in Drosophila. However, we identify one candidate meiotic driver in a centromere-linked region that shows an ∼8% increase in transmission frequency, corresponding to a ∼54:46 segregation ratio. Our results show that candidate meiotic drivers of moderate strength can be readily detected and localized in pools of BC1 progeny. PMID:28258181

  9. Design and characterization of a high-power ultrasound driver with ultralow-output impedance

    NASA Astrophysics Data System (ADS)

    Lewis, George K.; Olbricht, William L.

    2009-11-01

    We describe a pocket-sized ultrasound driver with an ultralow-output impedance amplifier circuit (less than 0.05 Ω) that can transfer more than 99% of the voltage from a power supply to the ultrasound transducer with minimal reflections. The device produces high-power acoustical energy waves while operating at lower voltages than conventional ultrasound driving systems because energy losses owing to mismatched impedance are minimized. The peak performance of the driver is measured experimentally with a PZT-4, 1.54 MHz, piezoelectric ceramic, and modeled using an adjusted Mason model over a range of transducer resonant frequencies. The ultrasound driver can deliver a 100 Vpp (peak to peak) square-wave signal across 0-8 MHz ultrasound transducers in 5 ms bursts through continuous wave operation, producing acoustic powers exceeding 130 W. Effects of frequency, output impedance of the driver, and input impedance of the transducer on the maximum acoustic output power of piezoelectric transducers are examined. The small size, high power, and efficiency of the ultrasound driver make this technology useful for research, medical, and industrial ultrasonic applications.

  10. Design and characterization of a high-power ultrasound driver with ultralow-output impedance.

    PubMed

    Lewis, George K; Olbricht, William L

    2009-11-01

    We describe a pocket-sized ultrasound driver with an ultralow-output impedance amplifier circuit (less than 0.05 ohms) that can transfer more than 99% of the voltage from a power supply to the ultrasound transducer with minimal reflections. The device produces high-power acoustical energy waves while operating at lower voltages than conventional ultrasound driving systems because energy losses owing to mismatched impedance are minimized. The peak performance of the driver is measured experimentally with a PZT-4, 1.54 MHz, piezoelectric ceramic, and modeled using an adjusted Mason model over a range of transducer resonant frequencies. The ultrasound driver can deliver a 100 V(pp) (peak to peak) square-wave signal across 0-8 MHz ultrasound transducers in 5 ms bursts through continuous wave operation, producing acoustic powers exceeding 130 W. Effects of frequency, output impedance of the driver, and input impedance of the transducer on the maximum acoustic output power of piezoelectric transducers are examined. The small size, high power, and efficiency of the ultrasound driver make this technology useful for research, medical, and industrial ultrasonic applications.

  11. Detecting medication errors in the New Zealand pharmacovigilance database: a retrospective analysis.

    PubMed

    Kunac, Desireé L; Tatley, Michael V

    2011-01-01

    Despite the traditional focus being adverse drug reactions (ADRs), pharmacovigilance centres have recently been identified as a potentially rich and important source of medication error data. To identify medication errors in the New Zealand Pharmacovigilance database (Centre for Adverse Reactions Monitoring [CARM]), and to describe the frequency and characteristics of these events. A retrospective analysis of the CARM pharmacovigilance database operated by the New Zealand Pharmacovigilance Centre was undertaken for the year 1 January-31 December 2007. All reports, excluding those relating to vaccines, clinical trials and pharmaceutical company reports, underwent a preventability assessment using predetermined criteria. Those events deemed preventable were subsequently classified to identify the degree of patient harm, type of error, stage of medication use process where the error occurred and origin of the error. A total of 1412 reports met the inclusion criteria and were reviewed, of which 4.3% (61/1412) were deemed preventable. Not all errors resulted in patient harm: 29.5% (18/61) were 'no harm' errors but 65.5% (40/61) of errors were deemed to have been associated with some degree of patient harm (preventable adverse drug events [ADEs]). For 5.0% (3/61) of events, the degree of patient harm was unable to be determined as the patient outcome was unknown. The majority of preventable ADEs (62.5% [25/40]) occurred in adults aged 65 years and older. The medication classes most involved in preventable ADEs were antibacterials for systemic use and anti-inflammatory agents, with gastrointestinal and respiratory system disorders the most common adverse events reported. For both preventable ADEs and 'no harm' events, most errors were incorrect dose and drug therapy monitoring problems consisting of failures in detection of significant drug interactions, past allergies or lack of necessary clinical monitoring. Preventable events were mostly related to the prescribing and administration stages of the medication use process, with the majority of errors 82.0% (50/61) deemed to have originated in the community setting. The CARM pharmacovigilance database includes medication errors, many of which were found to originate in the community setting and reported as ADRs. Error-prone situations were able to be identified, providing greater opportunity to improve patient safety. However, to enhance detection of medication errors by pharmacovigilance centres, reports should be prospectively reviewed for preventability and the reporting form revised to facilitate capture of important information that will provide meaningful insight into the nature of the underlying systems defects that caused the error.

  12. Circular tomosynthesis for neuro perfusion imaging on an interventional C-arm

    NASA Astrophysics Data System (ADS)

    Claus, Bernhard E.; Langan, David A.; Al Assad, Omar; Wang, Xin

    2015-03-01

    There is a clinical need to improve cerebral perfusion assessment during the treatment of ischemic stroke in the interventional suite. The clinician is able to determine whether the arterial blockage was successfully opened but is unable to sufficiently assess blood flow through the parenchyma. C-arm spin acquisitions can image the cerebral blood volume (CBV) but are challenged to capture the temporal dynamics of the iodinated contrast bolus, which is required to derive, e.g., cerebral blood flow (CBF) and mean transit time (MTT). Here we propose to utilize a circular tomosynthesis acquisition on the C-arm to achieve the necessary temporal sampling of the volume at the cost of incomplete data. We address the incomplete data problem by using tools from compressed sensing and incorporate temporal interpolation to improve our temporal resolution. A CT neuro perfusion data set is utilized for generating a dynamic (4D) volumetric model from which simulated tomo projections are generated. The 4D model is also used as a ground truth reference for performance evaluation. The performance that may be achieved with the tomo acquisition and 4D reconstruction (under simulation conditions, i.e., without considering data fidelity limitations due to imaging physics and imaging chain) is evaluated. In the considered scenario, good agreement between the ground truth and the tomo reconstruction in the parenchyma was achieved.

  13. Assessing cardiac function from total-variation-regularized 4D C-arm CT in the presence of angular undersampling

    NASA Astrophysics Data System (ADS)

    Taubmann, O.; Haase, V.; Lauritsch, G.; Zheng, Y.; Krings, G.; Hornegger, J.; Maier, A.

    2017-04-01

    Time-resolved tomographic cardiac imaging using an angiographic C-arm device may support clinicians during minimally invasive therapy by enabling a thorough analysis of the heart function directly in the catheter laboratory. However, clinically feasible acquisition protocols entail a highly challenging reconstruction problem which suffers from sparse angular sampling of the trajectory. Compressed sensing theory promises that useful images can be recovered despite massive undersampling by means of sparsity-based regularization. For a multitude of reasons—most notably the desired reduction of scan time, dose and contrast agent required—it is of great interest to know just how little data is actually sufficient for a certain task. In this work, we apply a convex optimization approach based on primal-dual splitting to 4D cardiac C-arm computed tomography. We examine how the quality of spatially and temporally total-variation-regularized reconstruction degrades when using as few as 6.9+/- 1.2 projection views per heart phase. First, feasible regularization weights are determined in a numerical phantom study, demonstrating the individual benefits of both regularizers. Secondly, a task-based evaluation is performed in eight clinical patients. Semi-automatic segmentation-based volume measurements of the left ventricular blood pool performed on strongly undersampled images show a correlation of close to 99% with measurements obtained from less sparsely sampled data.

  14. An augmented reality C-arm for intraoperative assessment of the mechanical axis: a preclinical study.

    PubMed

    Fallavollita, Pascal; Brand, Alexander; Wang, Lejing; Euler, Ekkehard; Thaller, Peter; Navab, Nassir; Weidert, Simon

    2016-11-01

    Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.

  15. The effect of X-ray beam distortion on the Edwards Sapien XT(™) trans-catheter aortic valve replacement prosthesis.

    PubMed

    Crowhurst, James A; Poon, Karl K; Murdoch, Dale; Incani, Alexander; Raffel, Owen C; Liddicoat, Annelise; Walters, Darren

    2015-12-01

    Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C-arm rotation that were required to bring the valve back to a coaxial appearance was recorded. When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C-arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth.

  16. Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szczykutowicz, Timothy P., E-mail: tszczykutowicz@uwhealth.org; Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705; Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706

    2016-02-15

    Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribedmore » gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.« less

  17. A wide bandgap silicon carbide (SiC) gate driver for high-temperature and high-voltage applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamichhane, Ranjan; Ericson, Milton Nance; Frank, Steven Shane

    2014-01-01

    Limitations of silicon (Si) based power electronic devices can be overcome with Silicon Carbide (SiC) because of its remarkable material properties. SiC is a wide bandgap semiconductor material with larger bandgap, lower leakage currents, higher breakdown electric field, and higher thermal conductivity, which promotes higher switching frequencies for high power applications, higher temperature operation, and results in higher power density devices relative to Si [1]. The proposed work is focused on design of a SiC gate driver to drive a SiC power MOSFET, on a Cree SiC process, with rise/fall times (less than 100 ns) suitable for 500 kHz tomore » 1 MHz switching frequency applications. A process optimized gate driver topology design which is significantly different from generic Si circuit design is proposed. The ultimate goal of the project is to integrate this gate driver into a Toyota Prius plug-in hybrid electric vehicle (PHEV) charger module. The application of this high frequency charger will result in lighter, smaller, cheaper, and a more efficient power electronics system.« less

  18. A Simple Wave Driver

    ERIC Educational Resources Information Center

    Temiz, Burak Kagan; Yavuz, Ahmet

    2015-01-01

    This study was done to develop a simple and inexpensive wave driver that can be used in experiments on string waves. The wave driver was made using a battery-operated toy car, and the apparatus can be used to produce string waves at a fixed frequency. The working principle of the apparatus is as follows: shortly after the car is turned on, the…

  19. Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions

    PubMed Central

    Sisniega, A.; Zbijewski, W.; Badal, A.; Kyprianou, I. S.; Stayman, J. W.; Vaquero, J. J.; Siewerdsen, J. H.

    2013-01-01

    Purpose: The proliferation of cone-beam CT (CBCT) has created interest in performance optimization, with x-ray scatter identified among the main limitations to image quality. CBCT often contends with elevated scatter, but the wide variety of imaging geometry in different CBCT configurations suggests that not all configurations are affected to the same extent. Graphics processing unit (GPU) accelerated Monte Carlo (MC) simulations are employed over a range of imaging geometries to elucidate the factors governing scatter characteristics, efficacy of antiscatter grids, guide system design, and augment development of scatter correction. Methods: A MC x-ray simulator implemented on GPU was accelerated by inclusion of variance reduction techniques (interaction splitting, forced scattering, and forced detection) and extended to include x-ray spectra and analytical models of antiscatter grids and flat-panel detectors. The simulator was applied to small animal (SA), musculoskeletal (MSK) extremity, otolaryngology (Head), breast, interventional C-arm, and on-board (kilovoltage) linear accelerator (Linac) imaging, with an axis-to-detector distance (ADD) of 5, 12, 22, 32, 60, and 50 cm, respectively. Each configuration was modeled with and without an antiscatter grid and with (i) an elliptical cylinder varying 70–280 mm in major axis; and (ii) digital murine and anthropomorphic models. The effects of scatter were evaluated in terms of the angular distribution of scatter incident upon the detector, scatter-to-primary ratio (SPR), artifact magnitude, contrast, contrast-to-noise ratio (CNR), and visual assessment. Results: Variance reduction yielded improvements in MC simulation efficiency ranging from ∼17-fold (for SA CBCT) to ∼35-fold (for Head and C-arm), with the most significant acceleration due to interaction splitting (∼6 to ∼10-fold increase in efficiency). The benefit of a more extended geometry was evident by virtue of a larger air gap—e.g., for a 16 cm diameter object, the SPR reduced from 1.5 for ADD = 12 cm (MSK geometry) to 1.1 for ADD = 22 cm (Head) and to 0.5 for ADD = 60 cm (C-arm). Grid efficiency was higher for configurations with shorter air gap due to a broader angular distribution of scattered photons—e.g., scatter rejection factor ∼0.8 for MSK geometry versus ∼0.65 for C-arm. Grids reduced cupping for all configurations but had limited improvement on scatter-induced streaks and resulted in a loss of CNR for the SA, Breast, and C-arm. Relative contribution of forward-directed scatter increased with a grid (e.g., Rayleigh scatter fraction increasing from ∼0.15 without a grid to ∼0.25 with a grid for the MSK configuration), resulting in scatter distributions with greater spatial variation (the form of which depended on grid orientation). Conclusions: A fast MC simulator combining GPU acceleration with variance reduction provided a systematic examination of a range of CBCT configurations in relation to scatter, highlighting the magnitude and spatial uniformity of individual scatter components, illustrating tradeoffs in CNR and artifacts and identifying the system geometries for which grids are more beneficial (e.g., MSK) from those in which an extended geometry is the better defense (e.g., C-arm head imaging). Compact geometries with an antiscatter grid challenge assumptions of slowly varying scatter distributions due to increased contribution of Rayleigh scatter. PMID:23635285

  20. Frequency and irregularity of heart rate in drivers suspected of driving under the influence of cannabis.

    PubMed

    Khiabani, Hassan Z; Mørland, Jørg; Bramness, Jørgen G

    2008-12-01

    Delta 9-tetrahydrocannabinol (THC) is the major active component of cannabis. Cardiovascular effects of THC have previously been reported: tachycardia after intake, but also bradycardia at higher doses. The purpose of this study was, firstly, to investigate the frequency and irregularity of heart rate in a group of cannabis users in their natural surroundings. We also compared THC-positive drivers with a regular pulse with THC-positive drivers with an irregular pulse. The division of Forensic Toxicology and Drug Abuse (DFTDA) at the Norwegian Institute of Public Heath analyzes blood samples from all drivers suspected of driving under the influence of drugs. We studied pulse rate and regularity in 502 THC-positive drivers who tested negative for other substances. As a control group, we randomly selected 125 drug-negative cases from the database of the DFTDA; no alcohol, narcotics, or medicinal drugs of abuse were detected. The Delta9-THC-positive drivers had a higher mean pulse rate than the control group [82.8 beats/min (SD 16.3) versus 75.6 beats/min (SD 9.2)] and more cases with tachycardia were detected in the Delta9-THC-positive group (19.4% versus 1.6%). There was only one driver with an irregular heart beat in the control group, while there were nine among the Delta9-THC-positive drivers. The drivers with an irregular pulse were over-represented amongst those with the lowest blood Delta9-THC concentrations. This report represents a large study of subjects in a real-life situation and includes observations on pulse frequency, regularity, and blood Delta9-THC concentration. A substantial fraction of Delta9-THC-positive drivers had tachycardia, but there was no correlation between blood Delta9-THC concentration and pulse rate in the present study. We had no further diagnostic information on the cause of the pulse irregularities, but our results indicate that occasional users of cannabis tend to have irregular heart rates at low THC concentrations and at low pulse rates.

  1. Mobile phone use during driving: Effects on speed and effectiveness of driver compensatory behaviour.

    PubMed

    Choudhary, Pushpa; Velaga, Nagendra R

    2017-09-01

    This study analysed and modelled the effects of conversation and texting (each with two difficulty levels) on driving performance of Indian drivers in terms of their mean speed and accident avoiding abilities; and further explored the relationship between speed reduction strategy of the drivers and their corresponding accident frequency. 100 drivers of three different age groups (young, mid-age and old-age) participated in the simulator study. Two sudden events of Indian context: unexpected crossing of pedestrians and joining of parked vehicles from road side, were simulated for estimating the accident probabilities. Generalized linear mixed models approach was used for developing linear regression models for mean speed and binary logistic regression models for accident probability. The results of the models showed that the drivers significantly compensated the increased workload by reducing their mean speed by 2.62m/s and 5.29m/s in the presence of conversation and texting tasks respectively. The logistic models for accident probabilities showed that the accident probabilities increased by 3 and 4 times respectively when the drivers were conversing or texting on a phone during driving. Further, the relationship between the speed reduction patterns and their corresponding accident frequencies showed that all the drivers compensated differently; but, among all the drivers, only few drivers, who compensated by reducing the speed by 30% or more, were able to fully offset the increased accident risk associated with the phone use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Detection of driver metabolites in the human liver metabolic network using structural controllability analysis

    PubMed Central

    2014-01-01

    Background Abnormal states in human liver metabolism are major causes of human liver diseases ranging from hepatitis to hepatic tumor. The accumulation in relevant data makes it feasible to derive a large-scale human liver metabolic network (HLMN) and to discover important biological principles or drug-targets based on network analysis. Some studies have shown that interesting biological phenomenon and drug-targets could be discovered by applying structural controllability analysis (which is a newly prevailed concept in networks) to biological networks. The exploration on the connections between structural controllability theory and the HLMN could be used to uncover valuable information on the human liver metabolism from a fresh perspective. Results We applied structural controllability analysis to the HLMN and detected driver metabolites. The driver metabolites tend to have strong ability to influence the states of other metabolites and weak susceptibility to be influenced by the states of others. In addition, the metabolites were classified into three classes: critical, high-frequency and low-frequency driver metabolites. Among the identified 36 critical driver metabolites, 27 metabolites were found to be essential; the high-frequency driver metabolites tend to participate in different metabolic pathways, which are important in regulating the whole metabolic systems. Moreover, we explored some other possible connections between the structural controllability theory and the HLMN, and find that transport reactions and the environment play important roles in the human liver metabolism. Conclusion There are interesting connections between the structural controllability theory and the human liver metabolism: driver metabolites have essential biological functions; the crucial role of extracellular metabolites and transport reactions in controlling the HLMN highlights the importance of the environment in the health of human liver metabolism. PMID:24885538

  3. An investigation of driver distraction near the tipping point of traffic flow stability.

    PubMed

    Cooper, Joel M; Vladisavljevic, Ivana; Medeiros-Ward, Nathan; Martin, Peter T; Strayer, David L

    2009-04-01

    The purpose of this study was to explore the interrelationship between driver distraction and characteristics of driver behavior associated with reduced highway traffic efficiency. Research on the three-phase traffic theory and on behavioral driving suggests that a number of characteristics associated with efficient traffic flow may be affected by driver distraction. Previous studies have been limited, however, by the fact that researchers typically do not allow participants to change lanes, nor do they account for the impact of varying traffic states on driving performance. Participants drove in three simulated environments with differing traffic congestion while both using and not using a cell phone. Instructed only to obey the speed limit, participants were allowed to vary driving behaviors, such as those involving forward following distance, speed, and lane-changing frequency. Both driver distraction and traffic congestion were found to significantly affect lane change frequency, mean speed, and the likelihood of remaining behind a slower-moving lead vehicle. This research suggests that the behavioral profile of "cell phone drivers," which is often described as compensatory, may have far-reaching and unexpected consequences for traffic efficiency. By considering the dynamic interplay between characteristics of traffic flow and driver behavior, this research may inform both public policy regarding in-vehicle cell phone use and future investigations of driving behavior.

  4. Classifying visuomotor workload in a driving simulator using subject specific spatial brain patterns

    PubMed Central

    Dijksterhuis, Chris; de Waard, Dick; Brookhuis, Karel A.; Mulder, Ben L. J. M.; de Jong, Ritske

    2013-01-01

    A passive Brain Computer Interface (BCI) is a system that responds to the spontaneously produced brain activity of its user and could be used to develop interactive task support. A human-machine system that could benefit from brain-based task support is the driver-car interaction system. To investigate the feasibility of such a system to detect changes in visuomotor workload, 34 drivers were exposed to several levels of driving demand in a driving simulator. Driving demand was manipulated by varying driving speed and by asking the drivers to comply to individually set lane keeping performance targets. Differences in the individual driver's workload levels were classified by applying the Common Spatial Pattern (CSP) and Fisher's linear discriminant analysis to frequency filtered electroencephalogram (EEG) data during an off line classification study. Several frequency ranges, EEG cap configurations, and condition pairs were explored. It was found that classifications were most accurate when based on high frequencies, larger electrode sets, and the frontal electrodes. Depending on these factors, classification accuracies across participants reached about 95% on average. The association between high accuracies and high frequencies suggests that part of the underlying information did not originate directly from neuronal activity. Nonetheless, average classification accuracies up to 75–80% were obtained from the lower EEG ranges that are likely to reflect neuronal activity. For a system designer, this implies that a passive BCI system may use several frequency ranges for workload classifications. PMID:23970851

  5. The Global Drivers of Photosynthesis and Light Use Efficiency Seasonality: A Granger Frequency Causality Analysis

    NASA Technical Reports Server (NTRS)

    Nemani, Ramakrishna R.

    2016-01-01

    Photosynthesis and light use efficiency (LUE) are major factors in the evolution of the continental carbon cycle due to their contribution to gross primary production (GPP). However, while the drivers of photosynthesis and LUE on a plant or canopy scale can often be identified, significant uncertainties exist when modeling these on a global scale. This is due to sparse observations in regions such as the tropics and the lack of a direct global observation dataset. Although others have attempted to address this issue using correlations (Beer, 2010) or calculating GPP from vegetation indices (Running, 2004), in this study we take a new approach. We combine the statistical method of Granger frequency causality and partial Granger frequency causality with remote sensing data products (including sun-induced fluorescence used as a proxy for GPP) to determine the main environmental drivers of GPP across the globe.

  6. Determinants and Drivers of Infectious Disease Threat Events in Europe.

    PubMed

    Semenza, Jan C; Lindgren, Elisabet; Balkanyi, Laszlo; Espinosa, Laura; Almqvist, My S; Penttinen, Pasi; Rocklöv, Joacim

    2016-04-01

    Infectious disease threat events (IDTEs) are increasing in frequency worldwide. We analyzed underlying drivers of 116 IDTEs detected in Europe during 2008-2013 by epidemic intelligence at the European Centre of Disease Prevention and Control. Seventeen drivers were identified and categorized into 3 groups: globalization and environment, sociodemographic, and public health systems. A combination of >2 drivers was responsible for most IDTEs. The driver category globalization and environment contributed to 61% of individual IDTEs, and the top 5 individual drivers of all IDTEs were travel and tourism, food and water quality, natural environment, global trade, and climate. Hierarchical cluster analysis of all drivers identified travel and tourism as a distinctly separate driver. Monitoring and modeling such disease drivers can help anticipate future IDTEs and strengthen control measures. More important, intervening directly on these underlying drivers can diminish the likelihood of the occurrence of an IDTE and reduce the associated human and economic costs.

  7. Determinants and Drivers of Infectious Disease Threat Events in Europe

    PubMed Central

    Lindgren, Elisabet; Balkanyi, Laszlo; Espinosa, Laura; Almqvist, My S.; Penttinen, Pasi; Rocklöv, Joacim

    2016-01-01

    Infectious disease threat events (IDTEs) are increasing in frequency worldwide. We analyzed underlying drivers of 116 IDTEs detected in Europe during 2008–2013 by epidemic intelligence at the European Centre of Disease Prevention and Control. Seventeen drivers were identified and categorized into 3 groups: globalization and environment, sociodemographic, and public health systems. A combination of >2 drivers was responsible for most IDTEs. The driver category globalization and environment contributed to 61% of individual IDTEs, and the top 5 individual drivers of all IDTEs were travel and tourism, food and water quality, natural environment, global trade, and climate. Hierarchical cluster analysis of all drivers identified travel and tourism as a distinctly separate driver. Monitoring and modeling such disease drivers can help anticipate future IDTEs and strengthen control measures. More important, intervening directly on these underlying drivers can diminish the likelihood of the occurrence of an IDTE and reduce the associated human and economic costs. PMID:26982104

  8. Investigating Driver Fatigue versus Alertness Using the Granger Causality Network.

    PubMed

    Kong, Wanzeng; Lin, Weicheng; Babiloni, Fabio; Hu, Sanqing; Borghini, Gianluca

    2015-08-05

    Driving fatigue has been identified as one of the main factors affecting drivers' safety. The aim of this study was to analyze drivers' different mental states, such as alertness and drowsiness, and find out a neurometric indicator able to detect drivers' fatigue level in terms of brain networks. Twelve young, healthy subjects were recruited to take part in a driver fatigue experiment under different simulated driving conditions. The Electroencephalogram (EEG) signals of the subjects were recorded during the whole experiment and analyzed by using Granger-Causality-based brain effective networks. It was that the topology of the brain networks and the brain's ability to integrate information changed when subjects shifted from the alert to the drowsy stage. In particular, there was a significant difference in terms of strength of Granger causality (GC) in the frequency domain and the properties of the brain effective network i.e., causal flow, global efficiency and characteristic path length between such conditions. Also, some changes were more significant over the frontal brain lobes for the alpha frequency band. These findings might be used to detect drivers' fatigue levels, and as reference work for future studies.

  9. Dose and detectability for a cone-beam C-arm CT system revisited

    PubMed Central

    Ganguly, Arundhuti; Yoon, Sungwon; Fahrig, Rebecca

    2010-01-01

    Purpose: The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose’s criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to (dose)1∕2. A more detailed analysis based on recent theoretical modeling of C-arm CT images is presented in this work. Methods: The signal and noise propagations in a C-arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x-ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose-criteria-based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results. Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to (dose)1∕3 and (dose)1∕2.8, respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose-criterion-based normalization. Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization. PMID:20527560

  10. Securing an OTL-HNS residency: how competitive is it? Comparing medical student perceptions to actual Canadian statistics.

    PubMed

    Kay-Rivest, E; Varma, N; Scott, G M; Manoukian, J J; Desrosiers, M; Vaccani, J P; Nguyen, L H P

    2017-02-27

    The residency match is an important event in an aspiring physician's career. Otolaryngology - Head and Neck Surgery (OTL-HNS) is a surgical specialty that has enjoyed high numbers of applicants to its residency programs. However, recent trends in Canada show a decline in first-choice applicants to several surgical fields. Factors thought to influence a medical student's choice include role models, career opportunities and work-life balance. The notion of perceived competitiveness is a factor that has not yet been explored. This study sought to compare competitiveness of OTL-HNS, as perceived by Canadian medical students to residency match statistics published yearly by CaRMS (Canadian Residency Matching Service), with the hope of informing future decisions of surgical residency programs. An electronic survey was created and distributed to all medical students enrolled in the 17 Canadian medical schools. After gathering demographic information, students were asked to rank what they perceived to be the five most competitive disciplines offered by CaRMS. They were also asked to rank surgical specialties from most to least competitive. Publically available data from CaRMS was then collected and analyzed to determine actual competitiveness of admissions to Canadian OTL-HNS residency programs. 1194 students, from first to fourth year of medical school, completed the survey. CaRMS statistics over the period from 2008 to 2014 demonstrated that the five most competitive specialties were Plastic Surgery, Dermatology, Ophthalmology, Emergency Medicine and OTL-HNS. Among surgical disciplines, OTL-HNS was third most competitive, where on average 72% of students match to their first-choice discipline. When students were questioned, 35% ranked OTL-HNS amongst the top five most competitive. On the other hand 72%, 74% and 80% recognized Opthalmology, Dermatology and Plastic Surgery as being among the five most competitive, respectively. We found that fourth-year medical students were significantly more knowledgeable about the competitiveness of both OTL-HNS and Plastic Surgery compared to first-year students (p < 0.01). Overall, Canadian medical students may underestimate the competitiveness of OTL-HNS. Furthermore, competitiveness would appear to be a concept that resonates with medical students during the match process.

  11. Radiation dose reduction and new image modalities development for interventional C-arm imaging system

    NASA Astrophysics Data System (ADS)

    Niu, Kai

    Cardiovascular disease and stroke are the leading health problems and causes of death in the US. Due to the minimally invasive nature of the evolution of image guided techniques, interventional radiological procedures are becoming more common and are preferred in treating many cardiovascular diseases and strokes. In addition, with the recent advances in hardware and device technology, the speed and efficacy of interventional treatment has significantly improved. This implies that more image modalities can be developed based on the current C-arm system and patients treated in interventional suites can potentially experience better health outcomes. However, during the treatment patients are irradiated with substantial amounts of ionizing radiation with a high dose rate (digital subtraction angiography (DSA) with 3muGy/frame and 3D cone beam CT image with 0.36muGy/frame for a Siemens Artis Zee biplane system) and/or a long irradiation time (a roadmapping image sequence can be as long as one hour during aneurysm embolization). As a result, the patient entrance dose is extremely high. Despite the fact that the radiation dose is already substantial, image quality is not always satisfactory. By default a temporal average is used in roadmapping images to overcome poor image quality, but this technique can result in motion blurred images. Therefore, reducing radiation dose while maintaining or even improving the image quality is an important area for continued research. This thesis is focused on improving the clinical applications of C-arm cone beam CT systems in two ways: (1) Improve the performance of current image modalities on the C-arm system. (2) Develop new image modalities based on the current system. To be more specific, the objectives are to reduce radiation dose for current modalities (e.g., DSA, fluoroscopy, roadmapping, and cone beam CT) and enable cone beam CT perfusion and time resolved cone beam CT angiography that can be used to diagnose and triage acute ischemic stroke patients more efficiently compared with the current clinical work-flow. The animal and patient cases presented in this thesis are focused towards but not limited to neurointerventional applications.

  12. Linear transformer driver for pulse generation

    DOEpatents

    Kim, Alexander A; Mazarakis, Michael G; Sinebryukhov, Vadim A; Volkov, Sergey N; Kondratiev, Sergey S; Alexeenko, Vitaly M; Bayol, Frederic; Demol, Gauthier; Stygar, William A

    2015-04-07

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first power delivery module that includes a first charge storage devices and a first switch. The first power delivery module sends a first energy in the form of a first pulse to the load. The linear transformer driver also includes a second power delivery module including a second charge storage device and a second switch. The second power delivery module sends a second energy in the form of a second pulse to the load. The second pulse has a frequency that is approximately three times the frequency of the first pulse. The at least one ferrite ring is positioned to force the first pulse and the second pulse to the load by temporarily isolating the first pulse and the second pulse from an electrical ground.

  13. High current nonlinear transmission line based electron beam driver

    NASA Astrophysics Data System (ADS)

    Hoff, B. W.; French, D. M.; Simon, D. S.; Lepell, P. D.; Montoya, T.; Heidger, S. L.

    2017-10-01

    A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV), were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage). Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage).

  14. Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection

    NASA Astrophysics Data System (ADS)

    Li, Yinsheng; Garrett, John W.; Li, Ke; Wu, Yijing; Johnson, Kevin; Schafer, Sebastian; Strother, Charles; Chen, Guang-Hong

    2018-04-01

    Time-resolved C-arm cone-beam CT (CBCT) angiography (TR-CBCTA) images can be generated from a series of CBCT acquisitions that satisfy data sufficiency condition in analytical image reconstruction theory. In this work, a new technique was developed to generate TR-CBCTA images from a single short-scan CBCT data acquisition with contrast media injection. The reconstruction technique enabling this application is a previously developed image reconstruction technique, synchronized multi-artifact reduction with tomographic reconstruction (SMART-RECON). In this new application, the acquired short-scan CBCT projection data were sorted into a union of several sub-sectors of view angles and each sub-sector of view angles corresponds to an individual image volume to be reconstructed. The SMART-RECON method was then used to jointly reconstruct all of these individual image volumes under two constraints: (1) each individual image volume is maximally consistent with the measured cone-beam projection data within the corresponding view angle sector and (2) the nuclear norm of the image matrix is minimized. The difference between these reconstructed individual image volumes is used to generated the desired subtracted angiograms. To validate the technique, numerical simulation data generated from a fractal tree angiogram phantom were used to quantitatively study the accuracy of the proposed method and retrospective in vivo human subject studies were used to demonstrate the feasibility of generating TR-CBCTA in clinical practice.

  15. Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization.

    PubMed

    Lee, Sing Chun; Fuerst, Bernhard; Fotouhi, Javad; Fischer, Marius; Osgood, Greg; Navab, Nassir

    2016-06-01

    This work proposes a novel algorithm to register cone-beam computed tomography (CBCT) volumes and 3D optical (RGBD) camera views. The co-registered real-time RGBD camera and CBCT imaging enable a novel augmented reality solution for orthopedic surgeries, which allows arbitrary views using digitally reconstructed radiographs overlaid on the reconstructed patient's surface without the need to move the C-arm. An RGBD camera is rigidly mounted on the C-arm near the detector. We introduce a calibration method based on the simultaneous reconstruction of the surface and the CBCT scan of an object. The transformation between the two coordinate spaces is recovered using Fast Point Feature Histogram descriptors and the Iterative Closest Point algorithm. Several experiments are performed to assess the repeatability and the accuracy of this method. Target registration error is measured on multiple visual and radio-opaque landmarks to evaluate the accuracy of the registration. Mixed reality visualizations from arbitrary angles are also presented for simulated orthopedic surgeries. To the best of our knowledge, this is the first calibration method which uses only tomographic and RGBD reconstructions. This means that the method does not impose a particular shape of the phantom. We demonstrate a marker-less calibration of CBCT volumes and 3D depth cameras, achieving reasonable registration accuracy. This design requires a one-time factory calibration, is self-contained, and could be integrated into existing mobile C-arms to provide real-time augmented reality views from arbitrary angles.

  16. Intraoperative Image-based Multiview 2D/3D Registration for Image-Guided Orthopaedic Surgery: Incorporation of Fiducial-Based C-Arm Tracking and GPU-Acceleration

    PubMed Central

    Armand, Mehran; Armiger, Robert S.; Kutzer, Michael D.; Basafa, Ehsan; Kazanzides, Peter; Taylor, Russell H.

    2012-01-01

    Intraoperative patient registration may significantly affect the outcome of image-guided surgery (IGS). Image-based registration approaches have several advantages over the currently dominant point-based direct contact methods and are used in some industry solutions in image-guided radiation therapy with fixed X-ray gantries. However, technical challenges including geometric calibration and computational cost have precluded their use with mobile C-arms for IGS. We propose a 2D/3D registration framework for intraoperative patient registration using a conventional mobile X-ray imager combining fiducial-based C-arm tracking and graphics processing unit (GPU)-acceleration. The two-stage framework 1) acquires X-ray images and estimates relative pose between the images using a custom-made in-image fiducial, and 2) estimates the patient pose using intensity-based 2D/3D registration. Experimental validations using a publicly available gold standard dataset, a plastic bone phantom and cadaveric specimens have been conducted. The mean target registration error (mTRE) was 0.34 ± 0.04 mm (success rate: 100%, registration time: 14.2 s) for the phantom with two images 90° apart, and 0.99 ± 0.41 mm (81%, 16.3 s) for the cadaveric specimen with images 58.5° apart. The experimental results showed the feasibility of the proposed registration framework as a practical alternative for IGS routines. PMID:22113773

  17. Interventional C-arm tomosynthesis for vascular imaging: initial results

    NASA Astrophysics Data System (ADS)

    Langan, David A.; Claus, Bernhard E. H.; Al Assad, Omar; Trousset, Yves; Riddell, Cyril; Avignon, Gregoire; Solomon, Stephen B.; Lai, Hao; Wang, Xin

    2015-03-01

    As percutaneous endovascular procedures address more complex and broader disease states, there is an increasing need for intra-procedure 3D vascular imaging. In this paper, we investigate C-Arm 2-axis tomosynthesis ("Tomo") as an alternative to C-Arm Cone Beam Computed Tomography (CBCT) for workflow situations in which the CBCT acquisition may be inconvenient or prohibited. We report on our experience in performing tomosynthesis acquisitions with a digital angiographic imaging system (GE Healthcare Innova 4100 Angiographic Imaging System, Milwaukee, WI). During a tomo acquisition the detector and tube each orbit on a plane above and below the table respectively. The tomo orbit may be circular or elliptical, and the tomographic half-angle in our studies varied from approximately 16 to 28 degrees as a function of orbit period. The trajectory, geometric calibration, and gantry performance are presented. We overview a multi-resolution iterative reconstruction employing compressed sensing techniques to mitigate artifacts associated with incomplete data reconstructions. In this work, we focus on the reconstruction of small high contrast objects such as iodinated vasculature and interventional devices. We evaluate the overall performance of the acquisition and reconstruction through phantom acquisitions and a swine study. Both tomo and comparable CBCT acquisitions were performed during the swine study thereby enabling the use of CBCT as a reference in the evaluation of tomo vascular imaging. We close with a discussion of potential clinical applications for tomo, reflecting on the imaging and workflow results achieved.

  18. [Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].

    PubMed

    Kotsianos, D; Rock, C; Wirth, S; Linsenmaier, U; Brandl, R; Fischer, T; Euler, E; Mutschler, W; Pfeifer, K J; Reiser, M

    2002-01-01

    To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR). Human knee specimens (n = 22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 degrees orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Müller AO classification. To confirm the results, the specimens were finally surgically dissected. 97 % of the tibial condylar fractures were easily seen and correctly classified according to the Müller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR. The evaluation of fractures with the ISO-C is better than with plain films alone and comparable to CT scans. The three-dimensional reconstruction of the ISO-C can provide important information which cannot be obtained from plain films. The ISO-C-3D may be useful in planning operative reconstructions and evaluating surgical results in orthopaedic surgery of the limbs.

  19. Probabilistic sparse matching for robust 3D/3D fusion in minimally invasive surgery.

    PubMed

    Neumann, Dominik; Grbic, Sasa; John, Matthias; Navab, Nassir; Hornegger, Joachim; Ionasec, Razvan

    2015-01-01

    Classical surgery is being overtaken by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm computed tomography (CT) and C-arm fluoroscopy are routinely used in clinical practice for intraoperative guidance. However, due to constraints regarding acquisition time and device configuration, intraoperative modalities have limited soft tissue image quality and reliable assessment of the cardiac anatomy typically requires contrast agent, which is harmful to the patient and requires complex acquisition protocols. We propose a probabilistic sparse matching approach to fuse high-quality preoperative CT images and nongated, noncontrast intraoperative C-arm CT images by utilizing robust machine learning and numerical optimization techniques. Thus, high-quality patient-specific models can be extracted from the preoperative CT and mapped to the intraoperative imaging environment to guide minimally invasive procedures. Extensive quantitative experiments on 95 clinical datasets demonstrate that our model-based fusion approach has an average execution time of 1.56 s, while the accuracy of 5.48 mm between the anchor anatomy in both images lies within expert user confidence intervals. In direct comparison with image-to-image registration based on an open-source state-of-the-art medical imaging library and a recently proposed quasi-global, knowledge-driven multi-modal fusion approach for thoracic-abdominal images, our model-based method exhibits superior performance in terms of registration accuracy and robustness with respect to both target anatomy and anchor anatomy alignment errors.

  20. Risk-Exposure Density and Mileage Bias in Crash Risk for Older Drivers

    PubMed Central

    Rolison, Jonathan J; Moutari, Salissou

    2018-01-01

    Abstract Crash rates per mile indicate a high risk of vehicle crash in older drivers. A reliance on mileage alone may underestimate the risk exposure of older drivers because they tend to avoid highways and travel more on nonfreeways (e.g., urban roads), which present greater hazards. We introduce risk-exposure density as an index of exposure that incorporates mileage, frequency of travel, and travel duration. Population-wide driver fatalities in the United States during 2002–2012 were assessed according to driver age range (in years: 16–20, 21–29, 30–39, 40–49, 50–59, 60–69, ≥70) and sex. Mileage, frequency, and duration of travel per person were used to assess risk exposure. Mileage-based fatal crash risk increased greatly among male (relative risk (RR) = 1.73; 95% CI: 1.62, 1.83) and female (RR = 2.08; 95% CI: 1.97, 2.19) drivers from ages 60–69 years to ages ≥70 years. Adjusting for their density of risk exposure, fatal crash risk increased only slightly from ages 60–69 years to ages ≥70 years among male (RR = 1.09; 95% CI: 1.03, 1.15) and female (RR = 1.22; 95% CI: 1.16, 1.29) drivers. While ubiquitous in epidemiologic research, mileage-based assessments can produce misleading accounts of driver risk. Risk-exposure density incorporates multiple components of travel and reduces bias caused by any single indicator of risk exposure. PMID:28605422

  1. Comparison of risk factors for tooth loss between professional drivers and white-collar workers: an internet survey.

    PubMed

    Suzuki, Seitaro; Yoshino, Koichi; Takayanagi, Atsushi; Ishizuka, Yoichi; Satou, Ryouichi; Kamijo, Hideyuki; Sugihara, Naoki

    2016-06-10

    This cross-sectional study was conducted to examine tooth loss and associated factors among professional drivers and white-collar workers. The participants were recruited by applying screening procedures to a pool of Japanese registrants in an online database. The participants were asked to complete a self-reported questionnaire. A total of 592 professional drivers and 328 white-collar workers (male, aged 30 to 69 years) were analyzed. A multiple logistic regression analysis was performed to identify differences between professional drivers and white-collar workers. The results showed that professional drivers had fewer teeth than white-collar workers (odds ratio [OR], 1.74; 95% confidence interval [95% CI], 1.150-2.625). Moreover, a second multiple logistic regression analysis revealed that several factors were associated with the number of teeth among professional drivers: diabetes mellitus (OR, 2.68; 95% CI, 1.388-5.173), duration of brushing teeth (OR, 1.66; 95% CI, 1.066-2.572), frequency of eating breakfast (OR, 2.23; 95% CI, 1.416-3.513), frequency of eating out (OR, 1.70; 95% CI, 1.086-2.671) and smoking status (OR, 2.88; 95% CI, 1.388-5.964). These findings suggest that the lifestyles of professional drivers could be related to not only their general health status, but also tooth loss.

  2. Driver performance and attention allocation in use of logo signs on freeway exit ramps.

    PubMed

    Zahabi, Maryam; Machado, Patricia; Lau, Mei Ying; Deng, Yulin; Pankok, Carl; Hummer, Joseph; Rasdorf, William; Kaber, David B

    2017-11-01

    The objective of this research was to quantify the effects of driver age, ramp signage configuration, including number of panels, logo format and sign familiarity, on driver performance and attention allocation when exiting freeways. Sixty drivers participated in a simulator study and analysis of variance models were used to assess response effects of the controlled manipulations. Results revealed elderly drivers to demonstrate worse performance and conservative control strategies as compared to middle-aged and young drivers. Elderly drivers also exhibited lower off-road fixation frequency and shorter off-road glance durations compared to middle-aged and young drivers. In general, drivers adopted a more conservative strategy when exposed to nine-panel signs as compared to six-panel signs and were more accurate in target detection when searching six-panels vs. nine and with familiar vs. unfamiliar logos. These findings provide an applicable guide for agency design of freeway ramp signage accounting for driver demographics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Driver behavior and accident frequency in school zones: Assessing the impact of sign saturation.

    PubMed

    Strawderman, Lesley; Rahman, Md Mahmudur; Huang, Yunchen; Nandi, Apurba

    2015-09-01

    Based on the models of human information processing, if a driver observes too many of the same signs, he or she may no longer pay attention to those signs. In the case of school zones, this expected effect may lead to non-compliance to posted speeds, negatively impacting safety around nearby schools. This study aims to investigate the effect of the number of nearby school zones on driver behavior (vehicle speed and compliance) and accident frequency. As a measure of the density of school zones, this study introduced and defined a new term sign saturation and presented a methodology to calculate sign saturation for school zones. Results found a significant effect of sign saturation on vehicle speed, compliance, and accident frequency. This study also examined the speeding behavior in school zones for different time of the day and day of the week. Results found that speeding was more prevalent in the early mornings and during the weekends. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Frequency, causes and human impact of motor vehicle-related road traffic accident (RTA) in Lubumbashi, Democratic Republic of Congo.

    PubMed

    Nangana, Luzitu Severin; Monga, Ben; Ngatu, Nlandu Roger; Mbelambela, Etongola Papy; Mbutshu, Lukuke Hendrick; Malonga, Kaj Francoise

    2016-09-01

    Road traffic accident (RTA)-related trauma remains a public health issue. The aim of this study was to determine the frequency, causes and human impact of motor vehicle-related RTA in Lubumbashi, Democratic Republic of Congo. A prospective cross-sectional study was conducted in the first semester of the year 2015 in which 288 drivers (144 RTA-causing drivers and 144 control drivers who have been declared not guilty by road safety agents) involved in 144 motor vehicle-related RTA were interviewed, and only data on all RTA involving two motor vehicles with at least four wheels were recorded and analyzed. Results showed a total of 144 RTA that involved two motor vehicles with four wheels occurring during the study period which affected 104 people, including 93 injury and 11 fatality cases. The mean age of RTA-causing drivers was 33.8 ± 7.4, whereas it was 35 ± 8.8 for control drivers. The majority of RTA-causing drivers (53.4 %) did not attend a driving school. Over speeding (32 %), distracted driving (22 %), overtaking (16 %) and careless driving/risky maneuver (15 %) and driving under the influence of alcohol (9 %) were the main causes of RTA occurrence. In addition, the absence of a valid driving license [aOR = 12.74 (±2.71); 95 % CI 3.877-41.916; p = 0.015], unfastened seat belt for the RTA-causing driver [aOR = 1.85 (±0.62); 95 % CI 1.306-6.661; p = 0.048] and presence of damages on RTA-causing vehicle [aOR = 33.56 (24.01); 95 % CI 1.429-78.352; p = 0.029] were associated with the occurrence of RTA-related fatality. This study showed a relatively high frequency of RTA occurring in Lubumbashi and suggests the necessity to reinforce road traffic regulation.

  5. Surveying the Impact of Work Hours and Schedules on Commercial Motor Vehicle Driver Sleep.

    PubMed

    Hege, Adam; Perko, Michael; Johnson, Amber; Yu, Chong Ho; Sönmez, Sevil; Apostolopoulos, Yorghos

    2015-06-01

    Given the long hours on the road involving multiple and interacting work stressors (i.e., delivery pressures, irregular shifts, ergonomic hazards), commercial drivers face a plethora of health and safety risks. Researchers goal was to determine whether and to what extent long-haul trucker work schedules influence sleep duration and quality. Survey and biometric data collected from male long-haul truck drivers at a major truckstop in central North Carolina over a six month period. Daily hours worked (mean = 11 hours, 55 minutes) and frequency of working over government-mandated daily HOS regulations (23.8% "frequently or always") were statistically significant predictors of sleep duration. Miles driven per week (mean = 2,812.61), irregular daily hours worked (63.8%), and frequency of working over the daily hour limit (23.8% "frequently or always") were statistically significant predictors of sleep quality. Implications of findings suggest a comprehensive review of the regulations and operational conditions for commercial motor vehicle drivers be undertaken.

  6. Automatic lumbar vertebrae detection based on feature fusion deep learning for partial occluded C-arm X-ray images.

    PubMed

    Yang Li; Wei Liang; Yinlong Zhang; Haibo An; Jindong Tan

    2016-08-01

    Automatic and accurate lumbar vertebrae detection is an essential step of image-guided minimally invasive spine surgery (IG-MISS). However, traditional methods still require human intervention due to the similarity of vertebrae, abnormal pathological conditions and uncertain imaging angle. In this paper, we present a novel convolutional neural network (CNN) model to automatically detect lumbar vertebrae for C-arm X-ray images. Training data is augmented by DRR and automatic segmentation of ROI is able to reduce the computational complexity. Furthermore, a feature fusion deep learning (FFDL) model is introduced to combine two types of features of lumbar vertebrae X-ray images, which uses sobel kernel and Gabor kernel to obtain the contour and texture of lumbar vertebrae, respectively. Comprehensive qualitative and quantitative experiments demonstrate that our proposed model performs more accurate in abnormal cases with pathologies and surgical implants in multi-angle views.

  7. Percutaneous foot joint needle placement using a C-arm flat-panel detector CT.

    PubMed

    Wiewiorski, Martin; Takes, Martin Thanh Long; Valderrabano, Victor; Jacob, Augustinus Ludwig

    2012-03-01

    Image guidance is valuable for diagnostic injections in foot orthopaedics. Flat-detector computed tomography (FD-CT) was implemented using a C-arm, and the system was tested for needle guidance in foot joint injections. FD-CT-guided joint infiltration was performed in 6 patients referred from the orthopaedic department for diagnostic foot injections. All interventions were performed utilising a flat-panel fluoroscopy system utilising specialised image guidance and planning software. Successful infiltration was defined by localisation of contrast media depot in the targeted joint. The pre- and post-interventional numeric analogue scale (NAS) pain score was assessed. All injections were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of symptoms was noted by all 6 participants. FD-CT-guided joint infiltration is a feasible method for diagnostic infiltration of midfoot and hindfoot joints. The FD-CT approach may become an alternative to commonly used 2D-fluoroscopically guidance.

  8. Needle and catheter navigation using electromagnetic tracking for computer-assisted C-arm CT interventions

    NASA Astrophysics Data System (ADS)

    Nagel, Markus; Hoheisel, Martin; Petzold, Ralf; Kalender, Willi A.; Krause, Ulrich H. W.

    2007-03-01

    Integrated solutions for navigation systems with CT, MR or US systems become more and more popular for medical products. Such solutions improve the medical workflow, reduce hardware, space and costs requirements. The purpose of our project was to develop a new electromagnetic navigation system for interventional radiology which is integrated into C-arm CT systems. The application is focused on minimally invasive percutaneous interventions performed under local anaesthesia. Together with a vacuum-based patient immobilization device and newly developed navigation tools (needles, panels) we developed a safe and fully automatic navigation system. The radiologist can directly start with navigated interventions after loading images without any prior user interaction. The complete system is adapted to the requirements of the radiologist and to the clinical workflow. For evaluation of the navigation system we performed different phantom studies and achieved an average accuracy of better than 2.0 mm.

  9. CIHR Candrive Cohort Comparison with Canadian Household Population Holding Valid Driver's Licenses.

    PubMed

    Gagnon, Sylvain; Marshall, Shawn; Kadulina, Yara; Stinchcombe, Arne; Bédard, Michel; Gélinas, Isabelle; Man-Son-Hing, Malcolm; Mazer, Barbara; Naglie, Gary; Porter, Michelle M; Rapoport, Mark; Tuokko, Holly; Vrkljan, Brenda

    2016-06-01

    We investigated whether convenience sampling is a suitable method to generate a sample of older drivers representative of the older-Canadian driver population. Using equivalence testing, we compared a large convenience sample of older drivers (Candrive II prospective cohort study) to a similarly aged population of older Canadian drivers. The Candrive sample consists of 928 community-dwelling older drivers from seven metropolitan areas of Canada. The population data was obtained from the Canadian Community Health Survey - Healthy Aging (CCHS-HA), which is a representative sample of older Canadians. The data for drivers aged 70 and older were extracted from the CCHS-HA database, for a total of 3,899 older Canadian drivers. Two samples were demonstrated as equivalent on socio-demographic, health, and driving variables that we compared, but not on driving frequency. We conclude that convenience sampling used in the Candrive study created a fairly representative sample of Canadian older drivers, with a few exceptions.

  10. Determining skill transferability of action games as a method to reduce in-vehicle phone distractions.

    PubMed

    Rupp, M; McConnell, D S; Smither, J A

    2012-01-01

    Distracted driving has been shown to be a safety issue in numerous studies. To combat this problem, in-vehicle technology, legislation, media interventions, and other methods have been proposed and attempted. However research indicates that the drivers themselves may circumvent, ignore, or not be able to react in time for these interventions to be effective. Therefore research into training programs for drivers may improve reaction time under distraction. Research indicates that action game players have faster reaction times and more attentional resources than non-players on paper-based tests. However, transferability to driving has not been studied yet. This paper outlines a study to determine if action game players perform better at a driving task based on frequency of game-play. Participants will be placed into two groups of play (high vs. low) and tested against two levels of distraction (none vs. phone conversation). It is expected that participants who play higher frequency of action games will perform better under distraction than lower frequency players. Driver performance, conversation recall, frequency and durations of eye fixations will be analyzed based on previous research which has validated those variables as a measure of distraction and higher workload.

  11. Upper ankle joint space detection on low contrast intraoperative fluoroscopic C-arm projections

    NASA Astrophysics Data System (ADS)

    Thomas, Sarina; Schnetzke, Marc; Brehler, Michael; Swartman, Benedict; Vetter, Sven; Franke, Jochen; Grützner, Paul A.; Meinzer, Hans-Peter; Nolden, Marco

    2017-03-01

    Intraoperative mobile C-arm fluoroscopy is widely used for interventional verification in trauma surgery, high flexibility combined with low cost being the main advantages of the method. However, the lack of global device-to- patient orientation is challenging, when comparing the acquired data to other intrapatient datasets. In upper ankle joint fracture reduction accompanied with an unstable syndesmosis, a comparison to the unfractured contralateral site is helpful for verification of the reduction result. To reduce dose and operation time, our approach aims at the comparison of single projections of the unfractured ankle with volumetric images of the reduced fracture. For precise assessment, a pre-alignment of both datasets is a crucial step. We propose a contour extraction pipeline to estimate the joint space location for a prealignment of fluoroscopic C-arm projections containing the upper ankle joint. A quadtree-based hierarchical variance comparison extracts potential feature points and a Hough transform is applied to identify bone shaft lines together with the tibiotalar joint space. By using this information we can define the coarse orientation of the projections independent from the ankle pose during acquisition in order to align those images to the volume of the fractured ankle. The proposed method was evaluated on thirteen cadaveric datasets consisting of 100 projections each with manually adjusted image planes by three trauma surgeons. The results show that the method can be used to detect the joint space orientation. The correlation between angle deviation and anatomical projection direction gives valuable input on the acquisition direction for future clinical experiments.

  12. Clinical implementation of intraoperative cone-beam CT in head and neck surgery

    NASA Astrophysics Data System (ADS)

    Daly, M. J.; Chan, H.; Nithiananthan, S.; Qiu, J.; Barker, E.; Bachar, G.; Dixon, B. J.; Irish, J. C.; Siewerdsen, J. H.

    2011-03-01

    A prototype mobile C-arm for cone-beam CT (CBCT) has been translated to a prospective clinical trial in head and neck surgery. The flat-panel CBCT C-arm was developed in collaboration with Siemens Healthcare, and demonstrates both sub-mm spatial resolution and soft-tissue visibility at low radiation dose (e.g., <1/5th of a typical diagnostic head CT). CBCT images are available ~15 seconds after scan completion (~1 min acquisition) and reviewed at bedside using custom 3D visualization software based on the open-source Image-Guided Surgery Toolkit (IGSTK). The CBCT C-arm has been successfully deployed in 15 head and neck cases and streamlined into the surgical environment using human factors engineering methods and expert feedback from surgeons, nurses, and anesthetists. Intraoperative imaging is implemented in a manner that maintains operating field sterility, reduces image artifacts (e.g., carbon fiber OR table) and minimizes radiation exposure. Image reviews conducted with surgical staff indicate bony detail and soft-tissue visualization sufficient for intraoperative guidance, with additional artifact management (e.g., metal, scatter) promising further improvements. Clinical trial deployment suggests a role for intraoperative CBCT in guiding complex head and neck surgical tasks, including planning mandible and maxilla resection margins, guiding subcranial and endonasal approaches to skull base tumours, and verifying maxillofacial reconstruction alignment. Ongoing translational research into complimentary image-guidance subsystems include novel methods for real-time tool tracking, fusion of endoscopic video and CBCT, and deformable registration of preoperative volumes and planning contours with intraoperative CBCT.

  13. Elevated Radiation Exposure Associated With Above Surface Flat Detector Mini C-Arm Use.

    PubMed

    Martin, Dennis P; Chapman, Talia; Williamson, Christopher; Tinsley, Brian; Ilyas, Asif M; Wang, Mark L

    2017-11-01

    This study aims to test the hypothesis that: (1) radiation exposure is increased with the intended use of Flat Surface Image Intensifier (FSII) units above the operative surface compared with the traditional below-table configuration; (2) this differential increases in a dose-dependent manner; and (3) radiation exposure varies with body part and proximity to the radiation source. A surgeon mannequin was seated at a radiolucent hand table, positioned for volar distal radius plating. Thermoluminescent dosimeters measured exposure to the eyes, thyroid, chest, hand, and groin, for 1- and 15-minute trials from a mini C-arm FSII unit positioned above and below the operating surface. Background radiation was measured by control dosimeters placed within the operating theater. At 1-minute of exposure, hand and eye dosages were significantly greater with the flat detector positioned above the table. At 15-minutes of exposure, hand radiation dosage exceeded that of all other anatomic sites with the FSII in both positions. Hand exposure was increased in a dose-dependent manner with the flat detector in either position, whereas groin exposure saw a dose-dependent only with the flat detector beneath the operating table. These findings suggest that the surgeon's hands and eyes may incur greater radiation exposure compared with other body parts, during routine mini C-arm FSII utilization in its intended position above the operating table. The clinical impact of these findings remains unclear, and future long-term radiation safety investigation is warranted. Surgeons should take precautions to protect critical body parts, particularly when using FSII technology above the operating with prolonged exposure time.

  14. Automatic 3D motion estimation of left ventricle from C-arm rotational angiocardiography using a prior motion model and learning based boundary detector.

    PubMed

    Chen, Mingqing; Zheng, Yefeng; Wang, Yang; Mueller, Kerstin; Lauritsch, Guenter

    2013-01-01

    Compared to pre-operative imaging modalities, it is more convenient to estimate the current cardiac physiological status from C-arm angiocardiography since C-arm is a widely used intra-operative imaging modality to guide many cardiac interventions. The 3D shape and motion of the left ventricle (LV) estimated from rotational angiocardiography provide important cardiac function measurements, e.g., ejection fraction and myocardium motion dyssynchrony. However, automatic estimation of the 3D LV motion is difficult since all anatomical structures overlap on the 2D X-ray projections and the nearby confounding strong image boundaries (e.g., pericardium) often cause ambiguities to LV endocardium boundary detection. In this paper, a new framework is proposed to overcome the aforementioned difficulties: (1) A new learning-based boundary detector is developed by training a boosting boundary classifier combined with the principal component analysis of a local image patch; (2) The prior LV motion model is learned from a set of dynamic cardiac computed tomography (CT) sequences to provide a good initial estimate of the 3D LV shape of different cardiac phases; (3) The 3D motion trajectory is learned for each mesh point; (4) All these components are integrated into a multi-surface graph optimization method to extract the globally coherent motion. The method is tested on seven patient scans, showing significant improvement on the ambiguous boundary cases with a detection accuracy of 2.87 +/- 1.00 mm on LV endocardium boundary delineation in the 2D projections.

  15. Registration-free laparoscope augmentation for intra-operative liver resection planning

    NASA Astrophysics Data System (ADS)

    Feuerstein, Marco; Mussack, Thomas; Heining, Sandro M.; Navab, Nassir

    2007-03-01

    In recent years, an increasing number of liver tumor indications were treated by minimally invasive laparoscopic resection. Besides the restricted view, a major issue in laparoscopic liver resection is the enhanced visualization of (hidden) vessels, which supply the tumorous liver segment and thus need to be divided prior to the resection. To navigate the surgeon to these vessels, pre-operative abdominal imaging data can hardly be used due to intraoperative organ deformations mainly caused by appliance of carbon dioxide pneumoperitoneum and respiratory motion. While regular respiratory motion can be gated and synchronized intra-operatively, motion caused by pneumoperitoneum is individual for every patient and difficult to estimate. Therefore, we propose to use an optically tracked mobile C-arm providing cone-beam CT imaging capability intraoperatively. The C-arm is able to visualize soft tissue by means of its new flat panel detector and is calibrated offline to relate its current position and orientation to the coordinate system of a reconstructed volume. Also the laparoscope is optically tracked and calibrated offline, so both laparoscope and C-arm are registered in the same tracking coordinate system. Intra-operatively, after patient positioning, port placement, and carbon dioxide insufflation, the liver vessels are contrasted and scanned during patient exhalation. Immediately, a three-dimensional volume is reconstructed. Without any further need for patient registration, the volume can be directly augmented on the live laparoscope video, visualizing the contrasted vessels. This augmentation provides the surgeon with advanced visual aid for the localization of veins, arteries, and bile ducts to be divided or sealed.

  16. Wines in contact with oak wood: the impact of the variety (Carménère and Cabernet Sauvignon), format (barrels, chips and staves) and aging time on the phenolic composition.

    PubMed

    Laqui-Estaña, Jaime; López-Solís, Remigio; Peña-Neira, Álvaro; Medel-Marabolí, Marcela; Obreque-Slier, Elías

    2018-06-13

    This study characterized the flavonoid and non-flavonoid phenolic composition of Carménère and Cabernet Sauvignon wines that were in contact with barrels, chips and staves during a 12-month aging period. The wines were evaluated by spectrophotometric (for total phenols, anthocyanins and tannins, colorant intensity, hue, CIElab parameters and fractionation into mono-, oligo- and polymer of proanthocyanidins) and HPLC-DAD analyses (for ellagitannins, gallotannins, anthocyanins and low molecular weight phenols). Wines in contact with oak wood presented a strong enrichment with non-flavonoid compounds, such as caffeic, gallic, ellagic acids and ellagitannins. Wines in contact with staves stood out for the increased presence of total phenols, vanillic acid and higher color intensity, while wines aged in contact with chips showed large contents of proanthocyanidin gallates. Wines aged in barrels exhibited high contents of ellagitannins and ethyl gallates. The effect of wood on the phenolic composition was mostly associated to the original and intrinsic characteristics of each grape variety. Extraction of phenolic compounds from oak wood during wine aging is closely related to the wood format, grape variety (Carménère or Cabernet Sauvignon) and aging time. The final effect of wood on wine would be related not just to the transference of polyphenols from wood but also to structural modifications of grape polyphenols. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. Truck drivers' opinion on road safety in Tanzania--a questionnaire study.

    PubMed

    Kircher, Katja; Andersson, Jan

    2013-01-01

    Even though the traffic fatality risk (fatalities per 100,000 inhabitants) in Tanzania is quite low, the fatality rate (fatalities per 10,000 vehicles) is one of the highest in the world. With increasing vehicle density this means that the number of people dying in traffic will increase dramatically in the near future. Therefore, it is important to implement measures to increase traffic safety as soon as possible, and in order to be able to do this in an efficient way, it is important to investigate where the main problems lie. Within the European Union (EU) project ASSET-Road a questionnaire study on road safety was conducted with 250 truck drivers in Tanzania. The study was done to increase the knowledge about the situation of the Tanzanian truckers, who are the most frequent road users in the country. The drivers were interviewed in 3 different towns in southern Tanzania, and participation was voluntary. The questionnaire treated demographics, the state of the drivers' vehicles, the frequency of breakdowns, and the maintenance of the vehicles. Further questions concerned driver behavior, crash involvement, crash risk, and crash mitigation. The drivers who participated in the study were predominantly male and their average age was 36 years. Truck drivers reported driving 10.6 h without a break on average, with several drivers reporting that they had to drive 24 h without rest. Around 40 percent of the trucks did not have any seat belts installed, with a larger share of older trucks lacking belts. Most of the drivers who had seat belts reported using them, however. Almost 40 percent of the drivers reported being involved in at least one crash, and 45 percent of those drivers had experienced fatal crashes. This underlines that the crash frequency per vehicle is very high, and the results are often severe, especially when heavy vehicles are involved. When asked what the 3 most common crash causations were, driver-related causes were named frequently. Drivers were said to be reckless, and further crash causations named were drunkenness, inattention, and sleepiness. One of the most frequently mentioned crash mitigation strategies was driver education, followed by improvement of the roads and the vehicles. The results indicate that countermeasures should be implemented in an integrated fashion, taking into account aspects such as driver, vehicle, infrastructure, legislature, and other road users.

  18. Collaborative adaptive rangeland management fosters management-science partnerships

    USDA-ARS?s Scientific Manuscript database

    Rangelands of the western Great Plains of North America are complex social-ecological systems where management objectives for livestock production, grassland bird conservation and vegetation structure and composition converge. The Collaborative Adaptive Rangeland Management (CARM) experiment is a 10...

  19. The Injury Risk to Wheelchair Occupants Using Motor Vehicle Transportation

    PubMed Central

    Songer, Thomas J.; Fitzgerald, Shirley G.; Rotko, Katherine A.

    2004-01-01

    The transportation safety experience for persons using wheelchairs is largely unknown. Motor vehicle crash involvement and injury frequency was examined in a telephone interview completed by 596 wheelchair users. Overall, 42% were drivers. Most subjects also rode as passengers in private vehicles (87%) and public vehicles (61%). Wheelchair use as a seat in the vehicle was higher among passengers than drivers. Crash involvement was highest among drivers and lower in passengers. Reported injuries from non-crash scenarios, though, were higher in passengers compared to drivers. Persons seated in wheelchairs in vehicles appear to be at a greater safety risk. PMID:15319121

  20. Radiation Awareness for Endovascular Abdominal Aortic Aneurysm Repair in the Hybrid Operating Room. An Instant Patient Risk Chart for Daily Practice.

    PubMed

    de Ruiter, Quirina M; Gijsberts, Crystel M; Hazenberg, Constantijn E; Moll, Frans L; van Herwaarden, Joost A

    2017-06-01

    To determine which patient and C-arm characteristics are the strongest predictors of intraoperative patient radiation dose rates (DRs) during endovascular aneurysm repair (EVAR) procedures and create a patient risk chart. A retrospective analysis was performed of 74 EVAR procedures, including 16,889 X-ray runs using fixed C-arm imaging equipment. Four multivariate log-linear mixed models (with patient as a random effect) were constructed. Mean air kerma DR (DR AK , mGy/s) and the mean dose area product DR (DR DAP , mGycm 2 /s) were the outcome variables utilized for fluoroscopy as differentiated from digital subtraction angiography (DSA). These models were used to predict the maximum radiation duration allowed before a 2-Gy skin threshold (for DR AK ) or a 500-Gycm 2 threshold (for DR DAP ) was reached. The strongest predictor of DR AK and DR DAP for fluoroscopy imaging was the radiation protocol, with an increase of 200% when changing from "low" to "medium" and 410% from "low" to "normal." The strongest predictors of DR AK and DR DAP for DSA were C-arm angulation, with an increase of 47% per 30° of angulation, and body mass index (BMI), with an increase of 58% for every 5-point increase in BMI. Based on these models, a patient with a BMI of 30 kg/m 2 , combined with 45° of rotation and a field size of 800 cm 2 in the medium fluoroscopy protocol has a predicted DR AK of 0.39 mGy/s (or 85.5 minutes until the 2-Gy skin threshold is reached). While using comparable settings but switching the acquisition to a DSA with a "2 frames per second" protocol, the predicted DR AK will be 6.6 mGy/s (or 5.0 minutes until the 2-Gy threshold is reached). X-ray radiation DRs are constantly fluctuating during and between patients based on BMI, the protocols, C-arm position, and the image acquisitions that are used. An instant patient risk chart visualizes these radiation dose fluctuations and provides an overview of the expected duration of X-ray radiation, which can be used to predict when follow-up dose thresholds are reached during abdominal endovascular procedures.

  1. Volumetric modulated arc therapy of head-and-neck cancer on a fast-rotating O-ring linac: Plan quality and delivery time comparison with a C-arm linac.

    PubMed

    Michiels, Steven; Poels, Kenneth; Crijns, Wouter; Delombaerde, Laurence; De Roover, Robin; Vanstraelen, Bianca; Haustermans, Karin; Nuyts, Sandra; Depuydt, Tom

    2018-05-05

    Linac improvements in gantry speed, leaf speed and dose rate may increase the time-efficiency of volumetric modulated arc therapy (VMAT) delivery. The plan quality achievable with faster VMAT however remains to be investigated. In this study, a fast-rotating O-ring linac with fast-moving leaves is compared with a C-arm linac in terms of plan quality and delivery time for VMAT of head-and-neck cancer (HNC). For 30 patients with HNC, treatment planning was performed using dual-arc (HA2) and triple-arc (HA3) VMAT on a Halcyon fast-rotating O-ring linac and using dual-arc VMAT on a TrueBeam C-arm linac (TB2). Target coverage metrics and complication probabilities were compared. Plan delivery was verified using 3%/3 mm gamma-index analysis of helical diode array measurements. Volumetric image acquisition and plan delivery times were compared. All studied VMAT-techniques fulfilled the target coverage objectives. D 2% to the boost volume was higher for HA2 (median 103.7%, 1st-3rd quartile [103.5%;104.0%]) and HA3 (103.2% [103.0%;103.7%)] than for TB2 (102.6% [102.3%;103.0%)], resulting in an increased boost target dose heterogeneity for HA2 and HA3. Complication probabilities were comparable between HA2 and TB2, while HA3 showed a xerostomia probability reduction (0.8% [0.2%;1.8%]) and dysphagia probability reduction (1.0% [0.2%;1.8%]) compared with TB2. Gamma-index agreement scores were never below 93.0% for HA2, HA3 and TB2. Volumetric imaging and plan delivery time was shorter for HA2 (1 m 24 s ± 1 s) and HA3 (1 m 54 s ± 1 s) than for TB2 (2 m 47 s ± 1 s). For VMAT of HNC, the fast-rotating O-ring linac at least maintains the plan quality of two arcs on a C-arm linac while reducing the image acquisition and plan delivery time. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Effect of traffic density on drivers' lane change and overtaking maneuvers in freeway situation - A driving simulator based study.

    PubMed

    Yang, Liu; Li, Xiaomeng; Guan, Wei; Zhang, H Michael; Fan, Lingling

    2018-05-14

    The aim of this study is to examine the effect of traffic density on drivers' lane change and overtaking maneuvers. The differences between drivers' left and right lane-changing/overtaking maneuvers were also investigated. A driving simulator experiment was conducted and 24 participants took part in this experiment. Based on the driving simulation data, lane change frequency, time duration, average speed and acceleration were extracted as key variables of lane change maneuvers; overtaking frequency, overtaking duration, initial overtaking distance and headway, instantaneous speed and acceleration before overtaking were analyzed as the key overtaking variables. One-way repeated measures ANOVA, Friedman test and Wilcoxon signed-rank test were adopted for hypothesis tests with significance level of 0.05. Further pairwise comparisons were performed with a Bonferroni correction for multiple comparisons. Some significant differences in lane change and overtake behaviors were observed among different traffic densities: 1) both lane change and overtaking frequencies significantly increase with traffic density; 2) the average lane change acceleration and instantaneous overtaking acceleration significantly increase with traffic density; 3) as the traffic density increases, the initial overtaking distance and headway decrease. As for the effect of the directions of maneuvers: 1) the time duration of lane change and overtaking from right side was significantly shorter than that from left side; 2) the right initial overtaking distance/headway was smaller than that of left side; 3) the right instantaneous overtaking acceleration was significantly higher than the left instantaneous acceleration. The results showed that as traffic density increases, drivers' intention for lane change and overtaking is enhanced. Both initial overtaking distance and headway decrease with traffic density, which might influence road safety. In addition, drivers do not show a preference on the directions of lane change or overtaking according to the frequency. However, drivers tend to be more decisive and reckless when conducting the right overtaking because of a smaller distance/headway before overtaking, higher instantaneous acceleration and also a more restricted field of view compared with left overtaking.

  3. Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schafer, S.; Nithiananthan, S.; Mirota, D. J.

    Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic andmore » lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.« less

  4. Traveler oriented traffic performance metrics using real time traffic data from the Midtown-in-Motion (MIM) project in Manhattan, NY.

    DOT National Transportation Integrated Search

    2013-10-01

    In a congested urban street network the average traffic speed is an inadequate metric for measuring : speed changes that drivers can perceive from changes in traffic control strategies. : A driver oriented metric is needed. Stop frequency distrib...

  5. High-frequency monopole sound source for anechoic chamber qualification

    NASA Astrophysics Data System (ADS)

    Saussus, Patrick; Cunefare, Kenneth A.

    2003-04-01

    Anechoic chamber qualification procedures require the use of an omnidirectional monopole sound source. Required characteristics for these monopole sources are explicitly listed in ISO 3745. Building a high-frequency monopole source that meets these characteristics has proved difficult due to the size limitations imposed by small wavelengths at high frequency. A prototype design developed for use in hemianechoic chambers employs telescoping tubes, which act as an inverse horn. This same design can be used in anechoic chambers, with minor adaptations. A series of gradually decreasing brass telescoping tubes is attached to the throat of a well-insulated high-frequency compression driver. Therefore, all of the sound emitted from the driver travels through the horn and exits through an opening of approximately 2.5 mm. Directivity test data show that this design meets all of the requirements set forth by ISO 3745.

  6. The influence of Driving Status on Transportation Challenges Experienced by Older Adults.

    PubMed

    Weeks, Lori E; Stadnyk, Robin; Begley, Lorraine; MacDonald, Dany J

    2015-06-01

    We explored the severity, number, and reasons for transportation challenges experienced by older adult drivers, nondrivers who live with a driver, and nondrivers who do not live with a driver. A random sample of 1,670 Atlantic Canadian community-dwelling older adults completed a mailed survey. Drivers comprised 80% of the participants. Just more than one fifth of participants experienced at least occasional transportation challenges. Two thirds of nondrivers who lived with a driver reported having no transportation challenges. Almost half of the nondrivers who did not live with a driver indicated never experiencing transportation challenges, and 84% of drivers had no transportation challenges. Nondrivers who did not live with a driver experienced greater frequency and severity of transportation challenges. This research contributes to our understanding of the characteristics of older adults with different driving statuses and their transportation challenges, which can contribute to providing appropriate transportation supports for older adults in the future. © The Author(s) 2013.

  7. Characterization of potential driver mutations involved in human breast cancer by computational approaches

    PubMed Central

    Rajendran, Barani Kumar; Deng, Chu-Xia

    2017-01-01

    Breast cancer is the second most frequently occurring form of cancer and is also the second most lethal cancer in women worldwide. A genetic mutation is one of the key factors that alter multiple cellular regulatory pathways and drive breast cancer initiation and progression yet nature of these cancer drivers remains elusive. In this article, we have reviewed various computational perspectives and algorithms for exploring breast cancer driver mutation genes. Using both frequency based and mutational exclusivity based approaches, we identified 195 driver genes and shortlisted 63 of them as candidate drivers for breast cancer using various computational approaches. Finally, we conducted network and pathway analysis to explore their functions in breast tumorigenesis including tumor initiation, progression, and metastasis. PMID:28477017

  8. UWB multi-burst transmit driver for averaging receivers

    DOEpatents

    Dallum, Gregory E

    2012-11-20

    A multi-burst transmitter for ultra-wideband (UWB) communication systems generates a sequence of precisely spaced RF bursts from a single trigger event. There are two oscillators in the transmitter circuit, a gated burst rate oscillator and a gated RF burst or RF power output oscillator. The burst rate oscillator produces a relatively low frequency, i.e., MHz, square wave output for a selected transmit cycle, and drives the RF burst oscillator, which produces RF bursts of much higher frequency, i.e., GHz, during the transmit cycle. The frequency of the burst rate oscillator sets the spacing of the RF burst packets. The first oscillator output passes through a bias driver to the second oscillator. The bias driver conditions, e.g., level shifts, the signal from the first oscillator for input into the second oscillator, and also controls the length of each RF burst. A trigger pulse actuates a timing circuit, formed of a flip-flop and associated reset time delay circuit, that controls the operation of the first oscillator, i.e., how long it oscillates (which defines the transmit cycle).

  9. Surveying the Impact of Work Hours and Schedules on Commercial Motor Vehicle Driver Sleep

    PubMed Central

    Hege, Adam; Perko, Michael; Johnson, Amber; Yu, Chong Ho; Sönmez, Sevil; Apostolopoulos, Yorghos

    2015-01-01

    Background Given the long hours on the road involving multiple and interacting work stressors (i.e., delivery pressures, irregular shifts, ergonomic hazards), commercial drivers face a plethora of health and safety risks. Researchers goal was to determine whether and to what extent long-haul trucker work schedules influence sleep duration and quality. Methods Survey and biometric data collected from male long-haul truck drivers at a major truckstop in central North Carolina over a six month period. Results Daily hours worked (mean = 11 hours, 55 minutes) and frequency of working over government-mandated daily HOS regulations (23.8% “frequently or always”) were statistically significant predictors of sleep duration. Miles driven per week (mean = 2,812.61), irregular daily hours worked (63.8%), and frequency of working over the daily hour limit (23.8% “frequently or always”) were statistically significant predictors of sleep quality. Conclusion Implications of findings suggest a comprehensive review of the regulations and operational conditions for commercial motor vehicle drivers be undertaken. PMID:26106509

  10. An epidemiological study of low back pain in professional drivers

    NASA Astrophysics Data System (ADS)

    Bovenzi, Massimo; Rui, Francesca; Negro, Corrado; D'Agostin, Flavia; Angotzi, Giuliano; Bianchi, Sandra; Bramanti, Lucia; Festa, GianLuca; Gatti, Silvana; Pinto, Iole; Rondina, Livia; Stacchini, Nicola

    2006-12-01

    The prevalence of low back pain (LBP) was investigated in 598 Italian professional drivers exposed to whole-body vibration (WBV) and ergonomic risk factors (drivers of earth moving machines, fork-lift truck drivers, truck drivers, bus drivers). The control group consisted of a small sample of 30 fire inspectors not exposed to WBV. Personal, occupational and health histories were collected by means of a structured questionnaire. Vibration measurements were performed on representative samples of the machines and vehicles used by the driver groups. From the vibration magnitudes and exposure durations, alternative measures of vibration dose were estimated for each subject. Daily vibration exposure, expressed in terms of 8-h energy-equivalent frequency-weighted acceleration, A(8), averaged 0.28-0.61 (range 0.10-1.18) m s -2 rms in the driver groups. Duration of exposure to WBV ranged between 1 and 41 years. The 7-day and 12-month prevalence of LBP was greater in the driver groups than in the controls. In the professional drivers, the occurrence of 12-month LBP, high intensity of LBP (Von Korff pain scale score ⩾5), and LBP disability (Roland & Morris disability scale score ⩾12) significantly increased with increasing cumulative vibration exposure. Even though several alternative measures of vibration exposure were associated with LBP outcomes, nevertheless a more regular trend of association with LBP was found for vibration dose expressed as ∑ a vit i (m s -2 h), in which the frequency-weighted acceleration, a v, and lifetime exposure duration, t, were given equal weight. In multivariate data analysis, individual characteristics (e.g. age, body mass index) and a physical load index (derived from combining manual materials handling and awkward postures) were significantly associated with LBP outcomes, while psychosocial work factors (e.g. job decision, job support) showed a marginal relation to LBP. This study tends to confirm that professional driving in industry is associated with an increased risk of work-related LBP. Exposure to WBV and physical loading factors at work are important components of the multifactorial origin of LBP in professional drivers.

  11. Video-guided calibration of an augmented reality mobile C-arm.

    PubMed

    Chen, Xin; Naik, Hemal; Wang, Lejing; Navab, Nassir; Fallavollita, Pascal

    2014-11-01

    The augmented reality (AR) fluoroscope augments an X-ray image by video and provides the surgeon with a real-time in situ overlay of the anatomy. The overlay alignment is crucial for diagnostic and intra-operative guidance, so precise calibration of the AR fluoroscope is required. The first and most complex step of the calibration procedure is the determination of the X-ray source position. Currently, this is achieved using a biplane phantom with movable metallic rings on its top layer and fixed X-ray opaque markers on its bottom layer. The metallic rings must be moved to positions where at least two pairs of rings and markers are isocentric in the X-ray image. The current "trial and error" calibration process currently requires acquisition of many X-ray images, a task that is both time consuming and radiation intensive. An improved process was developed and tested for C-arm calibration. Video guidance was used to drive the calibration procedure to minimize both X-ray exposure and the time involved. For this, a homography between X-ray and video images is estimated. This homography is valid for the plane at which the metallic rings are positioned and is employed to guide the calibration procedure. Eight users having varying calibration experience (i.e., 2 experts, 2 semi-experts, 4 novices) were asked to participate in the evaluation. The video-guided technique reduced the number of intra-operative X-ray calibration images by 89% and decreased the total time required by 59%. A video-based C-arm calibration method has been developed that improves the usability of the AR fluoroscope with a friendlier interface, reduced calibration time and clinically acceptable radiation doses.

  12. Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mory, Cyril, E-mail: cyril.mory@philips.com; Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes; Auvray, Vincent

    2014-02-15

    Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method,more » which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection.« less

  13. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications.

    PubMed

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-12-01

    To evaluate the radiation exposure for operating personnel associated with rotational flat-panel angiography and C-arm cone beam CT. Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8s/rotation, 20s/rotation and 5s/2 rotations), and 47 cm×18 cm (16s/2 rotations) and standard 2D angiography (10s, FOV 24 cm×18 cm). Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8s/rotation: 28.0 μSv, 20s/rotation: 79.3 μSv, 5s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20s/rotation). Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Automatic Intra-Operative Stitching of Non-Overlapping Cone-Beam CT Acquisitions

    PubMed Central

    Fotouhi, Javad; Fuerst, Bernhard; Unberath, Mathias; Reichenstein, Stefan; Lee, Sing Chun; Johnson, Alex A.; Osgood, Greg M.; Armand, Mehran; Navab, Nassir

    2018-01-01

    Purpose Cone-Beam Computed Tomography (CBCT) is one of the primary imaging modalities in radiation therapy, dentistry, and orthopedic interventions. While CBCT provides crucial intraoperative information, it is bounded by a limited imaging volume, resulting in reduced effectiveness. This paper introduces an approach allowing real-time intraoperative stitching of overlapping and non-overlapping CBCT volumes to enable 3D measurements on large anatomical structures. Methods A CBCT-capable mobile C-arm is augmented with a Red-Green-Blue-Depth (RGBD) camera. An off-line co-calibration of the two imaging modalities results in co-registered video, infrared, and X-ray views of the surgical scene. Then, automatic stitching of multiple small, non-overlapping CBCT volumes is possible by recovering the relative motion of the C-arm with respect to the patient based on the camera observations. We propose three methods to recover the relative pose: RGB-based tracking of visual markers that are placed near the surgical site, RGBD-based simultaneous localization and mapping (SLAM) of the surgical scene which incorporates both color and depth information for pose estimation, and surface tracking of the patient using only depth data provided by the RGBD sensor. Results On an animal cadaver, we show stitching errors as low as 0.33 mm, 0.91 mm, and 1.72mm when the visual marker, RGBD SLAM, and surface data are used for tracking, respectively. Conclusions The proposed method overcomes one of the major limitations of CBCT C-arm systems by integrating vision-based tracking and expanding the imaging volume without any intraoperative use of calibration grids or external tracking systems. We believe this solution to be most appropriate for 3D intraoperative verification of several orthopedic procedures. PMID:29569728

  15. Influence of the quality of intraoperative fluoroscopic images on the spatial positioning accuracy of a CAOS system.

    PubMed

    Wang, Junqiang; Wang, Yu; Zhu, Gang; Chen, Xiangqian; Zhao, Xiangrui; Qiao, Huiting; Fan, Yubo

    2018-06-01

    Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Two typical spatial positioning methods - a C-arm calibration-based method and a bi-planar positioning method - are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems. Copyright © 2018 John Wiley & Sons, Ltd.

  16. Multimode C-arm fluoroscopy, tomosynthesis, and cone-beam CT for image-guided interventions: from proof of principle to patient protocols

    NASA Astrophysics Data System (ADS)

    Siewerdsen, J. H.; Daly, M. J.; Bachar, G.; Moseley, D. J.; Bootsma, G.; Brock, K. K.; Ansell, S.; Wilson, G. A.; Chhabra, S.; Jaffray, D. A.; Irish, J. C.

    2007-03-01

    High-performance intraoperative imaging is essential to an ever-expanding scope of therapeutic procedures ranging from tumor surgery to interventional radiology. The need for precise visualization of bony and soft-tissue structures with minimal obstruction to the therapy setup presents challenges and opportunities in the development of novel imaging technologies specifically for image-guided procedures. Over the past ~5 years, a mobile C-arm has been modified in collaboration with Siemens Medical Solutions for 3D imaging. Based upon a Siemens PowerMobil, the device includes: a flat-panel detector (Varian PaxScan 4030CB); a motorized orbit; a system for geometric calibration; integration with real-time tracking and navigation (NDI Polaris); and a computer control system for multi-mode fluoroscopy, tomosynthesis, and cone-beam CT. Investigation of 3D imaging performance (noise-equivalent quanta), image quality (human observer studies), and image artifacts (scatter, truncation, and cone-beam artifacts) has driven the development of imaging techniques appropriate to a host of image-guided interventions. Multi-mode functionality presents a valuable spectrum of acquisition techniques: i.) fluoroscopy for real-time 2D guidance; ii.) limited-angle tomosynthesis for fast 3D imaging (e.g., ~10 sec acquisition of coronal slices containing the surgical target); and iii.) fully 3D cone-beam CT (e.g., ~30-60 sec acquisition providing bony and soft-tissue visualization across the field of view). Phantom and cadaver studies clearly indicate the potential for improved surgical performance - up to a factor of 2 increase in challenging surgical target excisions. The C-arm system is currently being deployed in patient protocols ranging from brachytherapy to chest, breast, spine, and head and neck surgery.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fetterly, K; Mathew, V

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of themore » aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.« less

  18. Prevalence of refraction errors and color blindness in heavy vehicle drivers.

    PubMed

    Erdoğan, Haydar; Ozdemir, Levent; Arslan, Seher; Cetin, Ilhan; Ozeç, Ayşe Vural; Cetinkaya, Selma; Sümer, Haldun

    2011-01-01

    To investigate the frequency of eye disorders in heavy vehicle drivers. A cross-sectional type study was conducted between November 2004 and September 2006 in 200 driver and 200 non-driver persons. A complete ophthalmologic examination was performed, including visual acuity, and dilated examination of the posterior segment. We used the auto refractometer for determining refractive errors. According to eye examination results, the prevalence of the refractive error was 21.5% and 31.3% in study and control groups respectively (P<0.05). The most common type of refraction error in the study group was myopic astigmatism (8.3%) while in the control group simple myopia (12.8%). Prevalence of dyschromatopsia in the rivers, control group and total group was 2.2%, 2.8% and 2.6% respectively. A considerably high number of drivers are in lack of optimal visual acuity. Refraction errors in drivers may impair the traffic security.

  19. Prevalence of refraction errors and color blindness in heavy vehicle drivers

    PubMed Central

    Erdoğan, Haydar; Özdemir, Levent; Arslan, Seher; Çetin, Ilhan; Özeç, Ayşe Vural; Çetinkaya, Selma; Sümer, Haldun

    2011-01-01

    AIM To investigate the frequency of eye disorders in heavy vehicle drivers. METHODS A cross-sectional type study was conducted between November 2004 and September 2006 in 200 driver and 200 non-driver persons. A complete ophthalmologic examination was performed, including visual acuity, and dilated examination of the posterior segment. We used the auto refractometer for determining refractive errors. RESULTS According to eye examination results, the prevalence of the refractive error was 21.5% and 31.3% in study and control groups respectively (P<0.05). The most common type of refraction error in the study group was myopic astigmatism (8.3%) while in the control group simple myopia (12.8%). Prevalence of dyschromatopsia in the rivers, control group and total group was 2.2%, 2.8% and 2.6% respectively. CONCLUSION A considerably high number of drivers are in lack of optimal visual acuity. Refraction errors in drivers may impair the traffic security. PMID:22553671

  20. Real-ear acoustical characteristics of impulse sound generated by golf drivers and the estimated risk to hearing: a cross-sectional study.

    PubMed

    Zhao, Fei; Bardsley, Barry

    2014-01-21

    This study investigated real-ear acoustical characteristics in terms of the sound pressure levels (SPLs) and frequency responses in situ generated from golf club drivers at impact with a golf ball. The risk of hearing loss caused by hitting a basket of golf balls using various drivers was then estimated. Cross-sectional study. The three driver clubs were chosen on the basis of reflection of the commonality and modern technology of the clubs. The participants were asked to choose the clubs in a random order and hit six two-piece range golf balls with each club. The experiment was carried out at a golf driving range in South Wales, UK. 19 male amateur golfers volunteered to take part in the study, with an age range of 19-54 years. The frequency responses and peak SPLs in situ of the transient sound generated from the club at impact were recorded bilaterally and simultaneously using the GN Otometric Freefit wireless real-ear measurement system. A swing speed radar system was also used to investigate the relationship between noise level and swing speed. Different clubs generated significantly different real-ear acoustical characteristics in terms of SPL and frequency responses. However, they did not differ significantly between the ears. No significant correlation was found between the swing speed and noise intensity. On the basis of the SPLs measured in the present study, the percentage of daily noise exposure for hitting a basket of golf balls using the drivers described above was less than 2%. The immediate danger of noise-induced hearing loss for amateur golfers is quite unlikely. However, it may be dangerous to hearing if the noise level generated by the golf clubs exceeded 116 dBA.

  1. [Correlation of clinicopathologic features and driver gene mutation in non-small cell lung cancer].

    PubMed

    Chen, L F; Chen, X Y; Yu, X B

    2016-04-08

    To study the relationship between mutations of well-known driver genes and clinicopathologic characteristics of non-small cell lung cancers (NSCLC). Scorpions amplification refractory mutation system (scorpions ARMS) fluorescence quantitative PCR was performed to investigate 205 driver gene mutation status in NSCLC in correlation with clinicopathological characteristics of the patients. Driver gene mutations were detected in 146 of 205 (71.2%) patients with NSCLC, including 81.7%(138/169) adenocarcinomas, in which mutations of nine genes were found: EGFR (63.3%, 107/169), KRAS (5.9%, 10/169), PIK3CA (4.1%, 7/169), ALK (4.1%, 7/169), ROS1 (3.0%, 5/169), RET (3.6%, 6/169), HER2 (1.8%, 3/169), NRAS (0.6%, 1/169) and BRAF (0.6%, 1/169). The frequencies of driver gene mutations were higher in adenocarcinomas, female patients and non-smokers (P<0.01, P=0.003, P<0.01, respectively). Driver gene mutation status showed no correlation with either the age or the clinical stage (P=0.281, P=0.490, respectively). However, EGFR mutations tended to occur in adenocarcinoma, female, non-smokers, and patients of ≥62 years of age (P<0.01, P<0.01, P=0.002, P=0.012, respectively). The frequency of EGFR mutation was positively correlated with the tumor histology of lepidic, acinar, papillary and micropapillary predominant growth patterns. There was no relationship between EGFR mutation and the clinical stage (P=0.237). The frequency of KRAS mutation was higher in solid predominant and invasive mucinous adenocarcinomas (P=0.015); that of PIK3CA mutation was higher in patients of ≥62 years of age, invasive mucinous adenocarcinoma and fetal adenocarcinoma (P=0.015, P=0.006, respectively). ALK, ROS1 or RET mutation positive NSCLC tended to occur in nonsmokers and have solid predominant tumors and invasive mucinous adenocarcinoma (P=0.012, P=0.017 respectively). The frequency of EML4-ALK mutation was higher in the early stage patients with solid predominant tumors and invasive mucinous adenocarcinomas (P=0.025, P=0.014, respectively); that of ROS1 rearrangement was higher in invasive mucinous adenocarcinomas (P=0.049). NRAS, BRAF and HER2 gene mutations were infrequent and their clinical significance remained to be elucidated. The relationship between mutations of well-known driver genes and clinicopathological characteristics in patients with NSCLC has diversity, the rate of mutations is higher in non-smoking female patients with adenocarcinoma.

  2. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    NASA Astrophysics Data System (ADS)

    Salleh, H.; Samat, S. B.; Matori, M. K.; Isa, M. J. M.

    2015-09-01

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.

  3. A novel technique for ventriculoperitoneal shunting by flat panel detector CT-guided real-time fluoroscopy

    PubMed Central

    Kobayashi, Shinya; Ishikawa, Tatsuya; Mutoh, Tatsushi; Hikichi, Kentaro; Suzuki, Akifumi

    2012-01-01

    Background: Surgical placement of a ventriculoperitoneal shunt (VPS) is the main strategy to manage hydrocephalus. However, the failure rate associated with placement of ventricular catheters remains high. Methods: A hybrid operating room, equipped with a flat-panel detector digital subtraction angiography system containing C-arm cone-beam computed tomography (CB-CT) imaging, has recently been developed and utilized to assist neurosurgical procedures. We have developed a novel technique using intraoperative fluoroscopy and a C-arm CB-CT system to facilitate accurate placement of a VPS. Results: Using this novel technique, 39 consecutive ventricular catheters were placed accurately, and no ventricular catheter failures were experienced during the follow-up period. Only two patients experienced obstruction of the VPS, both of which occurred in the extracranial portion of the shunt system. Conclusion: Surgical placement of a VPS assisted by flat panel detector CT-guided real-time fluoroscopy enabled accurate placement of ventricular catheters and was associated with a decreased need for shunt revision. PMID:23226605

  4. [Intraoperative augmented reality visualization. Current state of development and initial experiences with the CamC].

    PubMed

    Weidert, S; Wang, L; von der Heide, A; Navab, N; Euler, E

    2012-03-01

    The intraoperative application of augmented reality (AR) has so far mainly taken place in the field of endoscopy. Here, the camera image of the endoscope was augmented by computer graphics derived mostly from preoperative imaging. Due to the complex setup and operation of the devices, they have not yet become part of routine clinical practice. The Camera Augmented Mobile C-arm (CamC) that extends a classic C-arm by a video camera and mirror construction is characterized by its uncomplicated handling. It combines its video live stream geometrically correct with the acquired X-ray. The clinical application of the device in 43 cases showed the strengths of the device in positioning for X-ray acquisition, incision placement, K-wire placement, and instrument guidance. With its new function and the easy integration into the OR workflow of any procedure that requires X-ray imaging, the CamC has the potential to become the first widely used AR technology for orthopedic and trauma surgery.

  5. Design and development of C-arm based cone-beam CT for image-guided interventions: initial results

    NASA Astrophysics Data System (ADS)

    Chen, Guang-Hong; Zambelli, Joseph; Nett, Brian E.; Supanich, Mark; Riddell, Cyril; Belanger, Barry; Mistretta, Charles A.

    2006-03-01

    X-ray cone-beam computed tomography (CBCT) is of importance in image-guided intervention (IGI) and image-guided radiation therapy (IGRT). In this paper, we present a cone-beam CT data acquisition system using a GE INNOVA 4100 (GE Healthcare Technologies, Waukesha, Wisconsin) clinical system. This new cone-beam data acquisition mode was developed for research purposes without interfering with any clinical function of the system. It provides us a basic imaging pipeline for more advanced cone-beam data acquisition methods. It also provides us a platform to study and overcome the limiting factors such as cone-beam artifacts and limiting low contrast resolution in current C-arm based cone-beam CT systems. A geometrical calibration method was developed to experimentally determine parameters of the scanning geometry to correct the image reconstruction for geometric non-idealities. Extensive phantom studies and some small animal studies have been conducted to evaluate the performance of our cone-beam CT data acquisition system.

  6. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salleh, H.; Matori, M. K.; Isa, M. J. M.

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area ismore » clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.« less

  7. Simple trigonometry on computed tomography helps in planning renal access.

    PubMed

    Bilen, Cenk Yücel; Koçak, Burak; Kitirci, Gürcan; Danaci, Murat; Sarikaya, Saban

    2007-08-01

    To retrospectively assess the usefulness of the measurements on preoperative computed tomography (CT) of patients with urinary stone disease for planning the access site using vertical angulation of the C-arm. Of the patients who underwent percutaneous nephrolithotomy from November 2001 to October 2006, 41 patients with superior calix access had undergone preoperative CT. The depth of the target stone (y) and the vertical distance from that point to the first rib free slice (x) were measured on CT. The limit of the ratio of x over y was accepted as 0.58, with ratios below that indicating that infracostal access could be achieved by vertical angulation of the C-arm. We achieved an approach to the superior calix through an infracostal access in 28 patients. The preoperative trigonometric study on CT predicted 24 of them. The stone-free rate was 92.6%, and no chest-related complications developed. Simple trigonometry on CT of the patients with complex stones could help endourologists in planning renal access.

  8. Effects of Implementation Intentions on the Self-Reported Frequency of Drivers' Compliance with Speed Limits

    ERIC Educational Resources Information Center

    Elliott, Mark A.; Armitage, Christopher J.

    2006-01-01

    This study tested the efficacy of implementation intentions in the context of drivers' speeding behavior. Participants (N = 300) completed self-report measures of goal intention and behavior, and they were randomly assigned to an experimental condition, which required them to specify an implementation intention, or a control condition. One month…

  9. Linear transformer driver for pulse generation with fifth harmonic

    DOEpatents

    Mazarakis, Michael G.; Kim, Alexander A.; Sinebryukhov, Vadim A.; Volkov, Sergey N.; Kondratiev, Sergey S.; Alexeenko, Vitaly M.; Bayol, Frederic; Demol, Gauthier; Stygar, William A.; Leckbee, Joshua; Oliver, Bryan V.; Kiefer, Mark L.

    2017-03-21

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first, second, and third power delivery module. The first power delivery module sends a first energy in the form of a first pulse to the load. The second power delivery module sends a second energy in the form of a second pulse to the load. The third power delivery module sends a third energy in the form of a third pulse to the load. The linear transformer driver is configured to form a flat-top pulse by the superposition of the first, second, and third pulses. The first, second, and third pulses have different frequencies.

  10. A spectral power analysis of driving behavior changes during the transition from nondistraction to distraction.

    PubMed

    Wang, Yuan; Bao, Shan; Du, Wenjun; Ye, Zhirui; Sayer, James R

    2017-11-17

    This article investigated and compared frequency domain and time domain characteristics of drivers' behaviors before and after the start of distracted driving. Data from an existing naturalistic driving study were used. Fast Fourier transform (FFT) was applied for the frequency domain analysis to explore drivers' behavior pattern changes between nondistracted (prestarting of visual-manual task) and distracted (poststarting of visual-manual task) driving periods. Average relative spectral power in a low frequency range (0-0.5 Hz) and the standard deviation in a 10-s time window of vehicle control variables (i.e., lane offset, yaw rate, and acceleration) were calculated and further compared. Sensitivity analyses were also applied to examine the reliability of the time and frequency domain analyses. Results of the mixed model analyses from the time and frequency domain analyses all showed significant degradation in lateral control performance after engaging in visual-manual tasks while driving. Results of the sensitivity analyses suggested that the frequency domain analysis was less sensitive to the frequency bandwidth, whereas the time domain analysis was more sensitive to the time intervals selected for variation calculations. Different time interval selections can result in significantly different standard deviation values, whereas average spectral power analysis on yaw rate in both low and high frequency bandwidths showed consistent results, that higher variation values were observed during distracted driving when compared to nondistracted driving. This study suggests that driver state detection needs to consider the behavior changes during the prestarting periods, instead of only focusing on periods with physical presence of distraction, such as cell phone use. Lateral control measures can be a better indicator of distraction detection than longitudinal controls. In addition, frequency domain analyses proved to be a more robust and consistent method in assessing driving performance compared to time domain analyses.

  11. Value of C-Arm Cone Beam Computed Tomography Image Fusion in Maximizing the Versatility of Endovascular Robotics.

    PubMed

    Chinnadurai, Ponraj; Duran, Cassidy; Al-Jabbari, Odeaa; Abu Saleh, Walid K; Lumsden, Alan; Bismuth, Jean

    2016-01-01

    To report our initial experience and highlight the value of using intraoperative C-arm cone beam computed tomography (CT; DynaCT(®)) image fusion guidance along with steerable robotic endovascular catheter navigation to optimize vessel cannulation. Between May 2013 and January 2015, all patients who underwent endovascular procedures using DynaCT image fusion technique along with Hansen Magellan vascular robotic catheter were included in this study. As a part of preoperative planning, relevant vessel landmarks were electronically marked in contrast-enhanced multi-slice computed tomography images and stored. At the beginning of procedure, an intraoperative noncontrast C-arm cone beam CT (syngo DynaCT(®), Siemens Medical Solutions USA Inc.) was acquired in the hybrid suite. Preoperative images were then coregistered to intraoperative DynaCT images using aortic wall calcifications and bone landmarks. Stored landmarks were then overlaid on 2-dimensional (2D) live fluoroscopic images as virtual markers that are updated in real-time with C-arm, table movements and image zoom. Vascular access and robotic catheter (Magellan(®), Hansen Medical) was setup per standard. Vessel cannulation was performed based on electronic virtual markers on live fluoroscopy using robotic catheter. The impact of 3-dimensional (3D) image fusion guidance on robotic vessel cannulation was evaluated retrospectively, by assessing quantitative parameters like number of angiograms acquired before vessel cannulation and qualitative parameters like accuracy of vessel ostium and centerline markers. All 17 vessels were cannulated successfully in 14 patients' attempted using robotic catheter and image fusion guidance. Median vessel diameter at origin was 5.4 mm (range, 2.3-13 mm), whereas 12 of 17 (70.6%) vessels had either calcified and/or stenosed origin from parent vessel. Nine of 17 vessels (52.9 %) were cannulated without any contrast injection. Median number of angiograms required before cannulation was 0 (range, 0-2). On qualitative assessment, 14 of 15 vessels (93.3%) had grade = 1 accuracy (guidewire inside virtual ostial marker). Fourteen of 14 vessels had grade = 1 accuracy (virtual centerlines that matched with the actual vessel trajectory during cannulation). In this small series, the experience of using DynaCT image fusion guidance together with a steerable endovascular robotic catheter indicates that such image fusion strategies can enhance intraoperative 2D fluoroscopy by bringing preoperative 3D information about vascular stenosis and/or calcification, angulation, and take off from main vessel thereby facilitating ultimate vessel cannulation. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children.

    PubMed

    Shellikeri, Sphoorti; Setser, Randolph M; Hwang, Tiffany J; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Girard, Erin; Zhu, Xiaowei; Keller, Marc S; Cahill, Anne Marie

    2017-07-01

    Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0.005). In our experience, navigational software technology in the IR suite is a promising alternative to CT guidance for pediatric bone biopsies providing comparable technical success and diagnostic accuracy with lower radiation dose and procedure time, in addition to providing real-time fluoroscopic needle guidance.

  13. Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Y.; Maier, A.; Berger, M.

    2015-04-15

    Purpose: Three-dimensional (3D) volume-of-interest (VOI) imaging with C-arm systems provides anatomical information in a predefined 3D target region at a considerably low x-ray dose. However, VOI imaging involves laterally truncated projections from which conventional reconstruction algorithms generally yield images with severe truncation artifacts. Heuristic based extrapolation methods, e.g., water cylinder extrapolation, typically rely on techniques that complete the truncated data by means of a continuity assumption and thus appear to be ad-hoc. It is our goal to improve the image quality of VOI imaging by exploiting existing patient-specific prior information in the workflow. Methods: A necessary initial step prior tomore » a 3D acquisition is to isocenter the patient with respect to the target to be scanned. To this end, low-dose fluoroscopic x-ray acquisitions are usually applied from anterior–posterior (AP) and medio-lateral (ML) views. Based on this, the patient is isocentered by repositioning the table. In this work, we present a patient-bounded extrapolation method that makes use of these noncollimated fluoroscopic images to improve image quality in 3D VOI reconstruction. The algorithm first extracts the 2D patient contours from the noncollimated AP and ML fluoroscopic images. These 2D contours are then combined to estimate a volumetric model of the patient. Forward-projecting the shape of the model at the eventually acquired C-arm rotation views gives the patient boundary information in the projection domain. In this manner, we are in the position to substantially improve image quality by enforcing the extrapolated line profiles to end at the known patient boundaries, derived from the 3D shape model estimate. Results: The proposed method was evaluated on eight clinical datasets with different degrees of truncation. The proposed algorithm achieved a relative root mean square error (rRMSE) of about 1.0% with respect to the reference reconstruction on nontruncated data, even in the presence of severe truncation, compared to a rRMSE of 8.0% when applying a state-of-the-art heuristic extrapolation technique. Conclusions: The method we proposed in this paper leads to a major improvement in image quality for 3D C-arm based VOI imaging. It involves no additional radiation when using fluoroscopic images that are acquired during the patient isocentering process. The model estimation can be readily integrated into the existing interventional workflow without additional hardware.« less

  14. The impact of variation in low-frequency interaural cross correlation on auditory spatial imagery in stereophonic loudspeaker reproduction

    NASA Astrophysics Data System (ADS)

    Martens, William

    2005-04-01

    Several attributes of auditory spatial imagery associated with stereophonic sound reproduction are strongly modulated by variation in interaural cross correlation (IACC) within low frequency bands. Nonetheless, a standard practice in bass management for two-channel and multichannel loudspeaker reproduction is to mix low-frequency musical content to a single channel for reproduction via a single driver (e.g., a subwoofer). This paper reviews the results of psychoacoustic studies which support the conclusion that reproduction via multiple drivers of decorrelated low-frequency signals significantly affects such important spatial attributes as auditory source width (ASW), auditory source distance (ASD), and listener envelopment (LEV). A variety of methods have been employed in these tests, including forced choice discrimination and identification, and direct ratings of both global dissimilarity and distinct attributes. Contrary to assumptions that underlie industrial standards established in 1994 by ITU-R. Recommendation BS.775-1, these findings imply that substantial stereophonic spatial information exists within audio signals at frequencies below the 80 to 120 Hz range of prescribed subwoofer cutoff frequencies, and that loudspeaker reproduction of decorrelated signals at frequencies as low as 50 Hz can have an impact upon auditory spatial imagery. [Work supported by VRQ.

  15. The High-efficiency LED Driver for Visible Light Communication Applications.

    PubMed

    Gong, Cihun-Siyong Alex; Lee, Yu-Chen; Lai, Jyun-Liang; Yu, Chueh-Hao; Huang, Li Ren; Yang, Chia-Yen

    2016-08-08

    This paper presents a LED driver for VLC. The main purpose is to solve the low data rate problem used to be in switching type LED driver. The GaN power device is proposed to replace the traditional silicon power device of switching LED driver for the purpose of increasing switching frequency of converter, thereby increasing the bandwidth of data transmission. To achieve high efficiency, the diode-connected GaN power transistor is utilized to replace the traditional ultrafast recovery diode used to be in switching type LED driver. This work has been experimentally evaluated on 350-mA output current. The results demonstrate that it supports the data of PWM dimming level encoded in the PPM scheme for VLC application. The experimental results also show that system's efficiency of 80.8% can be achieved at 1-Mb/s data rate.

  16. Driver-Array Based Flat-Panel Loudspeakers: Theoretical Background and Design Guidelines

    NASA Astrophysics Data System (ADS)

    Anderson, David Allan

    This thesis relates to the simulation and design of flat-panel loudspeakers using moving-coil driver elements. A brief history of the industry is given, including a collection of products and patents from 1925 until the present, an overview of research papers, and a discussion of current products available. The mechanics of bending flat panels are developed with respect to localized driving forces, both in the frequency domain and the time domain as an impulse response. These simulations are compared to measurements on prototype panels. Additional resonant elements influence the behavior of the system: an optional ported rear enclosure and the resonant characteristics of the drivers. The governing equations for these systems are derived and solutions are implemented using equivalent mechanical circuits and numerical methods. The idea of using driver arrays to independently actuate modes of the panel is discussed at length with respect to modal addressability, modal spillover, and experimental validation. The numerical approach to determining the optimal driver placement for a given set of modes is derived and experimentally validated. An investigation of the acoustic behavior of flat panel loudspeakers is presented, using mechanical simulation results to predict the acoustic radiation. The simulations are compared to measurements and found to accurately predict important mechanical and acoustical behaviors. It is demonstrated that a driver array, with the proper biasing, is capable of creating a flat panel loudspeaker which acts more like a piston than a "diffuse radiator" flat panel loudspeaker. The techniques of "Modal Crossover Networks" are introduced, which use multi-band filters to bias the driver array differently for different frequency bands, optimized for audio reproduction. The question of how many drivers are necessary for a modal crossover network is addressed and found to be dependent on the estimated quality factor (Q) of the panel material and edge conditions.

  17. Experimental Research in Boost Driver with EDLCs

    NASA Astrophysics Data System (ADS)

    Matsumoto, Hirokazu

    The supply used in servo systems tends to have a high voltage in order to reduce loss and improve the response of motor drives. We propose a new boost motor driver that comprises EDLCs. The proposed driver has a simple structure, wherein the EDLCs are connected in series to the supply, and comprises a charge circuit to charge the EDLCs. The proposed driver has three advantages over conventional boost drivers. The first advantage is that the driver can easily attain the stable boost voltage. The second advantage is that the driver can reduce input power peaks. In a servo system, the input power peaks become greater than the rated power in order to accelerate the motor rapidly. This implies that the equipments that supply power to servo systems must have sufficient power capacity to satisfy the power peaks. The proposed driver can suppress the increase of the power capacity of supply facilities. The third advantage is that the driver can store almost all of the regenerative energy. Conventional drivers have a braking resistor to suppress the increase in the DC link voltage. This causes a considerable reduction in the efficiency. The proposed driver is more efficient than conventional drivers. In this study, the experimental results confirmed the effectiveness of the proposed driver and showed that the drive performance of the proposed driver is the same as that of a conventional driver. Furthermore, it was confirmed that the results of the simulation of a model of the EDLC module, whose capacitance is dependent on the frequency, correspond well with the experimental results.

  18. Predicting performance and safety based on driver fatigue.

    PubMed

    Mollicone, Daniel; Kan, Kevin; Mott, Chris; Bartels, Rachel; Bruneau, Steve; van Wollen, Matthew; Sparrow, Amy R; Van Dongen, Hans P A

    2018-04-02

    Fatigue causes decrements in vigilant attention and reaction time and is a major safety hazard in the trucking industry. There is a need to quantify the relationship between driver fatigue and safety in terms of operationally relevant measures. Hard-braking events are a suitable measure for this purpose as they are relatively easily observed and are correlated with collisions and near-crashes. We developed an analytic approach that predicts driver fatigue based on a biomathematical model and then estimates hard-braking events as a function of predicted fatigue, controlling for time of day to account for systematic variations in exposure (traffic density). The analysis used de-identified data from a previously published, naturalistic field study of 106 U.S. commercial motor vehicle (CMV) drivers. Data analyzed included drivers' official duty logs, sleep patterns measured around the clock using wrist actigraphy, and continuous recording of vehicle data to capture hard-braking events. The curve relating predicted fatigue to hard-braking events showed that the frequency of hard-braking events increased as predicted fatigue levels worsened. For each increment on the fatigue scale, the frequency of hard-braking events increased by 7.8%. The results provide proof of concept for a novel approach that predicts fatigue based on drivers' sleep patterns and estimates driving performance in terms of an operational metric related to safety. The approach can be translated to practice by CMV operators to achieve a fatigue risk profile specific to their own settings, in order to support data-driven decisions about fatigue countermeasures that cost-effectively deliver quantifiable operational benefits. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. [An analysis of the outlook for using C-arm-type mobile x-ray diagnostic apparatus].

    PubMed

    Blinov, N N; Mazurov, A I

    2000-01-01

    The fields and prospects of use of a C-arm surgical X-ray apparatus with an image amplifier on a tube made in Russia or in foreign countries and a CCD matrix are analyzed. Poor use of the capacities of the apparatus is noted.

  20. The impact of in-vehicle cell-phone use on accidents or near-accidents among college students.

    PubMed

    Seo, Dong-Chul; Torabi, Mohammad R

    2004-01-01

    With in-vehicle use of cell phones rapidly increasing, the safety of young drivers, who represent 14% of licensed drivers but 26% of drivers involved in fatal crashes, may be disproportionately threatened. The authors used a questionnaire to examine the association between in-vehicle cell-phone use and accidents or near-accidents among 1,291 conveniently recruited college students in 4 states. Of the 1,185 respondents who were drivers, 87% had a cell phone, and 86% of the cell-phone owners reported talking while driving at least occasionally. Of the 762 reported accidents or near-accidents, 21% (n = 159) involved at least 1 of the drivers talking while driving. Chi-square tests and logistic regression analyses showed that the frequency, not the duration, of drivers talking while driving was related to experiencing accidents or near-accidents. Differences between drivers who used cell phones and nonusers in unsafe driving behaviors and attitudes were also examined, and target groups for intervention efforts against talking on a cell phone while driving are suggested.

  1. Method for reworkable packaging of high speed, low electrical parasitic power electronics modules through gate drive integration

    DOEpatents

    Passmore, Brandon; Cole, Zach; Whitaker, Bret; Barkley, Adam; McNutt, Ty; Lostetter, Alexander

    2016-08-02

    A multichip power module directly connecting the busboard to a printed-circuit board that is attached to the power substrate enabling extremely low loop inductance for extreme environments such as high temperature operation. Wire bond interconnections are taught from the power die directly to the busboard further enabling enable low parasitic interconnections. Integration of on-board high frequency bus capacitors provide extremely low loop inductance. An extreme environment gate driver board allows close physical proximity of gate driver and power stage to reduce overall volume and reduce impedance in the control circuit. Parallel spring-loaded pin gate driver PCB connections allows a reliable and reworkable power module to gate driver interconnections.

  2. Development of Data Acquisition Card Driver for ICRH System on EAST

    NASA Astrophysics Data System (ADS)

    Liu, Daming; Luo, Jiarong; Zhao, Yanping; Qin, Chengming

    2008-04-01

    Presented in this paper is the development of the driver for the data acquisition card with a peripheral component interconnection (PCI) local bus on the ion cyclotron range of frequency heating (ICRH) system. The driver is mainly aimed at the embedded VxWorks system (real-time operating system) which is widely used in various fields of real-time systems. An efficient way is employed to develop this driver, which will advance the real-time control of the ICRH system on the experimental advanced superconductor tokamak (EAST). The driver is designed using the TORNADO integrated development environment (IDE), and implemented in C plus language. The details include the hardware configuration, analogue/digital (A/D) and digital/analogue (D/A) conversion, input and output (I/O) operation of the driver to support over five cards. The data acquisition card can be manipulated in a low-level program and meet the requirements of A/D conversion and D/A outputs.

  3. Novel concept for driving the linear compressor of a micro-miniature split Stirling cryogenic cooler

    NASA Astrophysics Data System (ADS)

    Maron, V.; Veprik, A.; Finkelstein, L.; Vilenchik, H.; Ziv, I.; Pundak, N.

    2009-05-01

    New methods of carrying out homeland security and antiterrorist operations call for the development of a new generation of mechanically cooled, portable, battery powered infrared imagers, relying on micro-miniature Stirling cryogenic coolers of rotary or linear types. Since split Stirling linearly driven micro-miniature cryogenic coolers have inherently longer life spans, low vibration export and better aural stealth as compared to their rotary driven rivals, they are more suitable for the above applications. The performance of such cryogenic coolers depends strongly on the efficacy of their electronic drivers. In a traditional approach, the PWM power electronics produce the fixed frequency tonal driving voltage/current, the magnitude of which is modulated via a PID control law so as to maintain the desired focal plane array temperature. The disadvantage of such drivers is that they draw high ripple current from the system's power bus. This results in the need for an oversized DC power supply (battery packs) and power electronic components, low efficiency due to excessive conductive losses and high residual electromagnetic interference which in turn degrades the performance of other systems connected to the same power bus. Without either an active line filter or large and heavy passive filtering, other electronics can not be powered from the same power bus, unless they incorporate heavy filtering at their inputs. The authors present the results of a feasibility study towards developing a novel "pumping" driver consuming essentially constant instant battery power/current without making use of an active or passive filter. In the tested setup, the driver relies on a bidirectional controllable bridge, invertible with the driving frequency, and a fast regulated DC/DC converter which maintains a constant level of current consumed from the DC power supply and thus operates in input current control mode. From the experimental results, the steady-state power consumed by the linear compressor remains the same as compared with the traditional sine wave driver, the voltage and current drawn from the battery pack is essentially free of low frequency ripple (this without use of any kind of filtering) and the overall coefficient of performance of the driver is in excess of 94% over the entire working range of supply voltages. Such a driver free of sine forming PWM stage and have reduced power peaks in all power conversion components.

  4. Generation of chaotic radiation in a driven traveling wave tube amplifier with time-delayed feedback

    NASA Astrophysics Data System (ADS)

    Marchewka, Chad; Larsen, Paul; Bhattacharjee, Sudeep; Booske, John; Sengele, Sean; Ryskin, Nikita; Titov, Vladimir

    2006-01-01

    The application of chaos in communications and radar offers new and interesting possibilities. This article describes investigations on the generation of chaos in a traveling wave tube (TWT) amplifier and the experimental parameters responsible for sustaining stable chaos. Chaos is generated in a TWT amplifier when it is made to operate in a highly nonlinear regime by recirculating a fraction of the TWT output power back to the input in a delayed feedback configuration. A driver wave provides a constant external force to the system making it behave like a forced nonlinear oscillator. The effects of the feedback bandwidth, intensity, and phase are described. The study illuminates the different transitions to chaos and the effect of parameters such as the frequency and intensity of the driver wave. The detuning frequency, i.e., difference frequency between the driver wave and the natural oscillation of the system, has been identified as being an important physical parameter for controlling evolution to chaos. Among the observed routes to chaos, besides the more common period doubling, a new route called loss of frequency locking occurs when the driving frequency is adjacent to a natural oscillation mode. The feedback bandwidth controls the nonlinear dynamics of the system, particularly the number of natural oscillation modes. A computational model has been developed to simulate the experiments and reasonably good agreement is obtained between them. Experiments are described that demonstrate the feasibility of chaotic communications using two TWTs, where one is operated as a driven chaotic oscillator and the other as a time-delayed, open-loop amplifier.

  5. TU-AB-204-02: Advances in C-Arm CBCT for Cardiac Interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fahrig, R.

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both themore » likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)« less

  6. TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, G.

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both themore » likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)« less

  7. The High-efficiency LED Driver for Visible Light Communication Applications

    PubMed Central

    Gong, Cihun-Siyong Alex; Lee, Yu-Chen; Lai, Jyun-Liang; Yu, Chueh-Hao; Huang, Li Ren; Yang, Chia-Yen

    2016-01-01

    This paper presents a LED driver for VLC. The main purpose is to solve the low data rate problem used to be in switching type LED driver. The GaN power device is proposed to replace the traditional silicon power device of switching LED driver for the purpose of increasing switching frequency of converter, thereby increasing the bandwidth of data transmission. To achieve high efficiency, the diode-connected GaN power transistor is utilized to replace the traditional ultrafast recovery diode used to be in switching type LED driver. This work has been experimentally evaluated on 350-mA output current. The results demonstrate that it supports the data of PWM dimming level encoded in the PPM scheme for VLC application. The experimental results also show that system’s efficiency of 80.8% can be achieved at 1-Mb/s data rate. PMID:27498921

  8. Subcutaneous morphine infusion by syringe driver for terminally ill patients.

    PubMed

    Cools, H J; Berkhout, A M; De Bock, G H

    1996-05-01

    The study aimed to find whether subcutaneous morphine administration by syringe driver for terminally ill patients in a Dutch nursing home led to higher morphine doses and earlier death than routine morphine administration. The data comprised the files of all patients dying over a 2 year period in a 355-bed nursing home in Delft in the Netherlands. Thirty-eight per cent of the patients had been given morphine, 29% by continuous subcutaneous syringe driver. In comparing the patients given morphine with and without a syringe driver no differences emerged in mean age, sex, length of admission, type of ward, diagnosis, duration of morphine administration and mean dose. The data indicate that subcutaneous morphine administration by syringe driver decreases dose frequency problems and improves the control of pain and other symptoms in the last week before death. There was no evidence that administration of morphine in this way shortens survival.

  9. Single-Stage Step up/down Driver for Permanent-Magnet Synchronous Machines

    NASA Astrophysics Data System (ADS)

    Chen, T. R.; Juan, Y. L.; Huang, C. Y.; Kuo, C. T.

    2017-11-01

    The two-stage circuit composed of a step up/down dc converter and a three-phase voltage source inverter is usually adopted as the electric vehicle’s motor driver. The conventional topology is more complicated. Additional power loss resulted from twice power conversion would also cause lower efficiency. A single-stage step up/down Permanent-Magnet Synchronous Motor driver for Brushless DC (BLDC) Motor is proposed in this study. The number components and circuit complexity are reduced. The low frequency six-step square-wave control is used to reduce the switching losses. In the proposed topology, only one active switch is gated with a high frequency PWM signal for adjusting the rotation speed. The rotor position signals are fed back to calculate the motor speed for digital close-loop control in a MCU. A 600W prototype circuit is constructed to drive a BLDC motor with rated speed 3000 rpm, and can control the speed of six sections.

  10. Human Sensibility Ergonomics Approach to Vehicle Simulator Based on Dynamics

    NASA Astrophysics Data System (ADS)

    Son, Kwon; Choi, Kyung-Hyun; Yoon, Ji-Sup

    Simulators have been used to evaluate drivers' reactions to various transportation products. Most research, however, has concentrated on their technical performance. This paper considers driver's motion perception on a vehicle simulator through the analysis of human sensibility ergonomics. A sensibility ergonomic method is proposed in order to improve the reliability of vehicle simulators. A simulator in a passenger vehicle consists of three main modules such as vehicle dynamics, virtual environment, and motion representation modules. To evaluate drivers' feedback, human perceptions are categorized into a set verbal expressions collected and investigated to find the most appropriate ones for translation and angular accelerations of the simulator. The cut-off frequency of the washout filter in the representation module is selected as one sensibility factor. Sensibility experiments were carried out to find a correlation between the expressions and the cut-off frequency of the filter. This study suggests a methodology to obtain an ergonomic database that can be applied to the sensibility evaluation of dynamic simulators.

  11. Comparison of visual status of Iranian military and commercial drivers.

    PubMed

    Ghasemi, Mohammad; Hoseini Yazdi, Seyed Hosein; Heravian, Javad; Jafarzadehpur, Ebrahim; Rezaee, Maryam

    2015-04-01

    There is no legal requirement for Iranian military truck drivers to undergo regular visual checkups as compared to commercial truck drivers. This study aimed to evaluate the impact of drivers' visual checkups by comparing the visual function of Iranian military and commercial truck drivers. In this comparative cross-sectional study, two hundred military and 200 commercial truck drivers were recruited and their Visual Acuity (VA), Visual Field (VF), color vision and Contrast Sensitivity (CS) were assessed and compared using the Snellen chart, confrontation screening method, D15 test and Pelli-Robson letter chart, respectively. A questionnaire regarding driving exposure and history of motor-vehicle crashes (MVCs) was also filled by drivers. Results were analyzed using an independent samples t-test, one-way ANOVA (assessing difference in number of MVCs across different age groups), chi-square test and Pearson correlation at statistical significance level of P < 0.05. Mean age was 41.6 ± 9.2 for the military truck drivers and 43.4 ± 10.9 for commercial truck drivers (P > 0.05). No significant difference between military and commercial drivers was found in terms of driving experience, number of MVCs, binocular VA, frequency of color vision defects and CS scores. In contrast, the last ocular examination was significantly earlier in military drivers than commercial drivers (P < 0.001). In addition, 4% of military drivers did not meet the national standards to drive as opposed to 2% of commercial drivers. There was a significant but weak correlation between binocular VA and age (r = 0.175, P < 0.001). However, CS showed a significantly moderate correlation with age (r = -0.488, P < 0.001). The absence of legal requirement for regular eye examination in military drivers caused the incompetent drivers to be missed in contrast to commercial drivers. The need for scientific revision of VA standard for Iranian drivers is also discussed. The CS measurement in visual checkups of older drivers deserves to be investigated more thoroughly.

  12. Driver behavior analysis for right-turn drivers at signalized intersections using SHRP 2 naturalistic driving study data.

    PubMed

    Wu, Jianqing; Xu, Hao

    2017-12-01

    Understanding driver behavior is important for traffic safety and operation, especially at intersections where different traffic movements conflict. While most driver-behavior studies are based on simulation, this paper documents the analysis of driver-behavior at signalized intersections with the SHRP 2 Naturalistic Driving Study (NDS) data. This study analyzes the different influencing factors on the operation (speed control) and observation of right-turn drivers. A total of 300 NDS trips at six signalized intersections were used, including the NDS time-series sensor data, the forward videos and driver face videos. Different factors of drivers, vehicles, roads and environments were studied for their influence on driver behavior. An influencing index function was developed and the index was calculated for each influencing factor to quantitatively describe its influencing level. The influencing index was applied to prioritize the factors, which facilitates development and selection of safety countermeasures to improve intersection safety. Drivers' speed control was analyzed under different conditions with consideration of the prioritized influencing factors. Vehicle type, traffic signal status, conflicting traffic, conflicting pedestrian and driver age group were identified as the five major influencing factors on driver observation. This research revealed that drivers have high acceleration and low observation frequency under Right-Turn-On-Red (RTOR), which constituted potential danger for other roadway users, especially for pedestrians. As speed has a direct influence on crash rates and severities, the revealed speed patterns of the different situations also benefit selection of safety countermeasures at signalized intersections. Published by Elsevier Ltd.

  13. A retrospective mortality study among Canadian petroleum marketing and distribution workers.

    PubMed Central

    Schnatter, A R; Katz, A M; Nicolich, M J; Thériault, G

    1993-01-01

    We conducted a retrospective mortality study among 6672 petroleum marketing and distribution workers from 226 locations throughout Canada. These employees worked for at least 1 year in the marketing distribution segment from 1964 through 1983 or were annuitants as of 1964. Industrial hygienists assigned hydrocarbon (HC) exposure frequency scores for several jobs, departments, and job functions. We computed standardized mortality ratios for the total cohort, HC exposure frequency groups, and tank truck drivers, and we also used Poisson regression techniques to model mortality for selected causes of death according to HC exposure frequency. Results indicate overall mortality below that of the general Canadian population for all marketing distribution workers [Standardized mortality ratio (SMR) = 0.88]. Mortality from aortic aneurysms was significantly elevated in all marketing/distribution workers (SMR = 1.79) but was due to raised mortality in nonexposed workers (SMR = 2.80). Tank truck drivers showed significantly elevated mortality due to leukemia (SMR = 3.35) based on five deaths. The leukemia findings were not evident in the larger group of marketing distribution workers classified as exposed to hydrocarbons (SMR = 1.01). No other cause of death was elevated in truck drivers. The leukemia findings are suggestive of a possible influence due to exposure to HCs in tank truck drivers, although other explanations cannot be ruled out. Other findings of elevated mortality in the marketing distribution group are generally not statistically significant. These included moderately increased mortality due to multiple myeloma, malignant melanoma, and kidney cancer. Small numbers of observed and expected deaths limit concise interpretations for these diseases. PMID:8020452

  14. HEARING IMPAIRMENT AND HYPERTENSION AMONG LONG DISTANCE BUS DRIVERS

    PubMed Central

    Abdelmoneim, Ismail

    2003-01-01

    Objectives: To investigate the prevalence of possible hearing impairment and hypertension in long distance bus drivers compared to the city bus drivers in Abha city. Methods: This was a cross-sectional study involving 62 long distance bus drivers and 46 city bus drivers from October 2001 to March 2002. A specially-designed questionnaire was administered to the drivers to explore some of their socioeconomic backgrounds. A pure tone air conduction audiometry and blood pressure measurements were performed. Results: Long distance bus drivers’ workload is significantly higher than that of city drivers (total weekly hours 64.0±14.3 compared to 46.7±5.5). Hearing impairment was significantly more among long distance drivers in the frequencies of 250, 500, 1000 and 2000 Hz especially in the left ear even after age corrections. The prevalence of mild hearing loss and hypertension were also higher among the long distance drivers (19.4% vs 4.5% and 38.7% vs 13% respectively). Conclusion and recommendations: This study showed more hearing affection and a higher prevalence of hypertension among long distance bus drivers than their counterparts operating in the city. Their hearing acuity should be tested before they start work and regularly afterwards. The stresses and strains of the job should be further studied and relieved; and regular health checks including blood pressure monitoring are to be instituted. PMID:23012034

  15. Correlation between driving errors and vigilance level: influence of the driver's age.

    PubMed

    Campagne, Aurelie; Pebayle, Thierry; Muzet, Alain

    2004-01-01

    During long and monotonous driving at night, most drivers progressively show signs of visual fatigue and loss of vigilance. Their capacity to maintain adequate driving performance usually is affected and varies with the age of the driver. The main question is to know, on one hand, if occurrence of fatigue and drowsiness is accompanied by a modification in the driving performance of the driver and, on the other hand, if this relationship partially depends on the driver's age. Forty-six male drivers, divided into three age categories: 20-30, 40-50, and 60-70 years, performed a 350-km motorway driving session at night on a driving simulator. Driving errors were measured in terms of number of running-off-the-road incidents (RORI) and large speed deviations. The evolution of physiological vigilance level was evaluated using electroencephalography (EEG) recording. In older drivers, in comparison with young and middle-aged drivers, the degradation of driving performance was correlated to the evolution of lower frequency waking EEG (i.e., theta). Contrary to young and middle-aged drivers, the deterioration of the vigilance level attested by EEG correlated with the increase in gravity of all studied driving errors in older drivers. Thus, depending on the age category considered, only part of the driving errors would constitute a relevant indication as for the occurrence of a state of low arousal.

  16. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maier, Andreas; Wigstroem, Lars; Hofmann, Hannes G.

    2011-11-15

    Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-raymore » views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold speed-up of the processing (from 1336 to 150 s). Conclusions: Adaptive anisotropic filtering has the potential to substantially improve image quality and/or reduce the radiation dose required for obtaining 3D image data using cone beam CT.« less

  17. A practical laboratory study simulating the percutaneous lumbar transforaminal epidural injection: training model in fresh cadaveric sheep spine.

    PubMed

    Suslu, Husnu

    2012-01-01

    Laboratory training models are essential for developing and refining treatment skills before the clinical application of surgical and invasive procedures. A simple simulation model is needed for young trainees to learn how to handle instruments, and to perform safe lumbar transforaminal epidural injections. Our aim is to present a model of a fresh cadaveric sheep lumbar spine that simulates the lumbar transforaminal epidural injection. The material consists of a 2-year-old fresh cadaveric sheep spine. A 4-step approach was designed for lumbar transforaminal epidural injection under C-arm scopy. For the lumbar transforaminal epidural injection, the fluoroscope was adjusted to get a proper oblique view while the material was stabilized in a prone position. The procedure then begin, using the C-arm guidance scopy. The model simulates well the steps of standard lumbar transforaminal epidural injections in the human spine. The cadaveric sheep spine represents a good method for training and it simulates fluoroscopic lumbar transforaminal epidural steroid injection procedures performed in the human spine.

  18. 3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy

    NASA Astrophysics Data System (ADS)

    Uneri, A.; Otake, Y.; Wang, A. S.; Kleinszig, G.; Vogt, S.; Khanna, A. J.; Siewerdsen, J. H.

    2014-01-01

    An algorithm for intensity-based 3D-2D registration of CT and x-ray projections is evaluated, specifically using single- or dual-projection views to provide 3D localization. The registration framework employs the gradient information similarity metric and covariance matrix adaptation evolution strategy to solve for the patient pose in six degrees of freedom. Registration performance was evaluated in an anthropomorphic phantom and cadaver, using C-arm projection views acquired at angular separation, Δθ, ranging from ˜0°-180° at variable C-arm magnification. Registration accuracy was assessed in terms of 2D projection distance error and 3D target registration error (TRE) and compared to that of an electromagnetic (EM) tracker. The results indicate that angular separation as small as Δθ ˜10°-20° achieved TRE <2 mm with 95% confidence, comparable or superior to that of the EM tracker. The method allows direct registration of preoperative CT and planning data to intraoperative fluoroscopy, providing 3D localization free from conventional limitations associated with external fiducial markers, stereotactic frames, trackers and manual registration.

  19. Real-ear acoustical characteristics of impulse sound generated by golf drivers and the estimated risk to hearing: a cross-sectional study

    PubMed Central

    Zhao, Fei; Bardsley, Barry

    2014-01-01

    Objectives This study investigated real-ear acoustical characteristics in terms of the sound pressure levels (SPLs) and frequency responses in situ generated from golf club drivers at impact with a golf ball. The risk of hearing loss caused by hitting a basket of golf balls using various drivers was then estimated. Design Cross-sectional study. Setting The three driver clubs were chosen on the basis of reflection of the commonality and modern technology of the clubs. The participants were asked to choose the clubs in a random order and hit six two-piece range golf balls with each club. The experiment was carried out at a golf driving range in South Wales, UK. Participants 19 male amateur golfers volunteered to take part in the study, with an age range of 19–54 years. Outcome measures The frequency responses and peak SPLs in situ of the transient sound generated from the club at impact were recorded bilaterally and simultaneously using the GN Otometric Freefit wireless real-ear measurement system. A swing speed radar system was also used to investigate the relationship between noise level and swing speed. Results Different clubs generated significantly different real-ear acoustical characteristics in terms of SPL and frequency responses. However, they did not differ significantly between the ears. No significant correlation was found between the swing speed and noise intensity. On the basis of the SPLs measured in the present study, the percentage of daily noise exposure for hitting a basket of golf balls using the drivers described above was less than 2%. Conclusions The immediate danger of noise-induced hearing loss for amateur golfers is quite unlikely. However, it may be dangerous to hearing if the noise level generated by the golf clubs exceeded 116 dBA. PMID:24448845

  20. Changes in functional connectivity dynamics associated with vigilance network in taxi drivers.

    PubMed

    Shen, Hui; Li, Zhenfeng; Qin, Jian; Liu, Qiang; Wang, Lubin; Zeng, Ling-Li; Li, Hong; Hu, Dewen

    2016-01-01

    An increasing number of neuroimaging studies have suggested that the fluctuations of low-frequency resting-state functional connectivity (FC) are not noise but are instead linked to the shift between distinct cognitive states. However, there is very limited knowledge about whether and how the fluctuations of FC at rest are influenced by long-term training and experience. Here, we investigated how the dynamics of resting-state FC are linked to driving behavior by comparing 20 licensed taxi drivers with 20 healthy non-drivers using a sliding window approach. We found that the driving experience could be effectively decoded with 90% (p<0.001) accuracy by the amplitude of low-frequency fluctuations in some specific connections, based on a multivariate pattern analysis technique. Interestingly, the majority of these connections fell within a set of distributed regions named "the vigilance network". Moreover, the decreased amplitude of the FC fluctuations within the vigilance network in the drivers was negatively correlated with the number of years that they had driven a taxi. Furthermore, temporally quasi-stable functional connectivity segmentation revealed significant differences between the drivers and non-drivers in the dwell time of specific vigilance-related transient brain states, although the brain's repertoire of functional states was preserved. Overall, these results suggested a significant link between the changes in the time-dependent aspects of resting-state FC within the vigilance network and long-term driving experiences. The results not only improve our understanding of how the brain supports driving behavior but also shed new light on the relationship between the dynamics of functional brain networks and individual behaviors. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. On the road again after traumatic brain injury: driver safety and behaviour following on-road assessment and rehabilitation.

    PubMed

    Ross, Pamela; Ponsford, Jennie L; Di Stefano, Marilyn; Charlton, Judith; Spitz, Gershon

    2016-01-01

    To examine pre- and post-injury self-reported driver behaviour and safety in individuals with traumatic brain injury (TBI) who returned to driving after occupational therapy driver assessment and on-road rehabilitation. A self-report questionnaire, administered at an average of 4.5 years after completing an on-road driver assessment, documenting pre- and post-injury crash rates, near-crashes, frequency of driving, distances driven, driving conditions avoided and navigation skills, was completed by 106 participants, who had either passed the initial driver assessment (pass group n = 74), or required driver rehabilitation, prior to subsequent assessments (rehabilitation group n = 32). No significant difference was found between pre- and post-injury crash rates. Compared to pre-injury, 36.8% of drivers reported limiting driving time, 40.6% drove more slowly, 41.5% reported greater difficulty with navigating and 20.0% reported more near-crashes. The rehabilitation group (with greater injury severity) was significantly more likely to drive less frequently, shorter distances, avoid: driving with passengers, busy traffic, night and freeway driving than the pass group. Many drivers with moderate/severe TBI who completed a driver assessment and rehabilitation program at least 3 months post-injury, reported modifying their driving behaviour, and did not report more crashes compared to pre-injury. On-road driver training and training in navigation may be important interventions in driver rehabilitation programs. Driver assessment and on-road retraining are important aspects of rehabilitation following traumatic brain injury. Many drivers with moderate/severe TBI, reported modifying their driving behaviour to compensate for ongoing impairment and continued to drive safely in the longer term. Navigational difficulties were commonly experienced following TBI, suggesting that training in navigation may be an important aspect of driver rehabilitation.

  2. Stable And Oscillating Acoustic Levitation

    NASA Technical Reports Server (NTRS)

    Barmatz, Martin B.; Garrett, Steven L.

    1988-01-01

    Sample stability or instability determined by levitating frequency. Degree of oscillation of acoustically levitated object along axis of levitation chamber controlled by varying frequency of acoustic driver for axis above or below frequency of corresponding chamber resonance. Stabilization/oscillation technique applied in normal Earth gravity, or in absence of gravity to bring object quickly to rest at nominal levitation position or make object oscillate in desired range about that position.

  3. Controlling Sample Rotation in Acoustic Levitation

    NASA Technical Reports Server (NTRS)

    Barmatz, M. B.; Stoneburner, J. D.

    1985-01-01

    Rotation of acoustically levitated object stopped or controlled according to phase-shift monitoring and control concept. Principle applies to square-cross-section levitation chamber with two perpendicular acoustic drivers operating at same frequency. Phase difference between X and Y acoustic excitation measured at one corner by measuring variation of acoustic amplitude sensed by microphone. Phase of driver adjusted to value that produces no rotation or controlled rotation of levitated object.

  4. Intermittent operation of QC-lasers for mid-IR spectroscopy with low heat dissipation: tuning characteristics and driving electronics.

    PubMed

    Fischer, M; Tuzson, B; Hugi, A; Brönnimann, R; Kunz, A; Blaser, S; Rochat, M; Landry, O; Müller, A; Emmenegger, L

    2014-03-24

    Intermittent scanning for continuous-wave quantum cascade lasers is proposed along with a custom-built laser driver optimized for such operation. This approach lowers the overall heat dissipation of the laser by dropping its drive current to zero between individual scans and holding a longer pause between scans. This allows packaging cw-QCLs in TO–3 housings with built-in collimating optics, thus reducing cost and footprint of the device. The fully integrated, largely analog, yet flexible laser driver eliminates the need for any external electronics for current modulation, lowers the demands on power supply performance, and allows shaping of the tuning current in a wide range. Optimized ramp shape selection leads to large and nearly linear frequency tuning (>1.5 cm−1). Experimental characterization of the proposed scheme with a QCL emitting at 7.7 μm gave a frequency stability of 3.2×10−5 cm−1 for the laser emission, while a temperature dependence of 2.3×10−4 cm−1/K was observed when the driver electronics was exposed to sudden temperature changes. We show that these characteristics make the driver suitable for high precision trace gas measurements by analyzing methane absorption lines in the respective spectral region.

  5. Driver Behavior During Overtaking Maneuvers from the 100-Car Naturalistic Driving Study.

    PubMed

    Chen, Rong; Kusano, Kristofer D; Gabler, Hampton C

    2015-01-01

    Lane changes with the intention to overtake the vehicle in front are especially challenging scenarios for forward collision warning (FCW) designs. These overtaking maneuvers can occur at high relative vehicle speeds and often involve no brake and/or turn signal application. Therefore, overtaking presents the potential of erroneously triggering the FCW. A better understanding of driver behavior during lane change events can improve designs of this human-machine interface and increase driver acceptance of FCW. The objective of this study was to aid FCW design by characterizing driver behavior during lane change events using naturalistic driving study data. The analysis was based on data from the 100-Car Naturalistic Driving Study, collected by the Virginia Tech Transportation Institute. The 100-Car study contains approximately 1.2 million vehicle miles of driving and 43,000 h of data collected from 108 primary drivers. In order to identify overtaking maneuvers from a large sample of driving data, an algorithm to automatically identify overtaking events was developed. The lead vehicle and minimum time to collision (TTC) at the start of lane change events was identified using radar processing techniques developed in a previous study. The lane change identification algorithm was validated against video analysis, which manually identified 1,425 lane change events from approximately 126 full trips. Forty-five drivers with valid time series data were selected from the 100-Car study. From the sample of drivers, our algorithm identified 326,238 lane change events. A total of 90,639 lane change events were found to involve a closing lead vehicle. Lane change events were evenly distributed between left side and right side lane changes. The characterization of lane change frequency and minimum TTC was divided into 10 mph speed bins for vehicle travel speeds between 10 and 90 mph. For all lane change events with a closing lead vehicle, the results showed that drivers change lanes most frequently in the 40-50 mph speed range. Minimum TTC was found to increase with travel speed. The variability in minimum TTC between drivers also increased with travel speed. This study developed and validated an algorithm to detect lane change events in the 100-Car Naturalistic Driving Study and characterized lane change events in the database. The characterization of driver behavior in lane change events showed that driver lane change frequency and minimum TTC vary with travel speed. The characterization of overtaking maneuvers from this study will aid in improving the overall effectiveness of FCW systems by providing active safety system designers with further understanding of driver action in overtaking maneuvers, thereby increasing system warning accuracy, reducing erroneous warnings, and improving driver acceptance.

  6. [Precision of navigation-assisted surgery of the thoracic and lumbar spine].

    PubMed

    Arand, M; Schempf, M; Hebold, D; Teller, S; Kinzl, L; Gebhard, F

    2003-11-01

    The goal of these studies was to evaluate the accuracy of in vivo and in vitro application of CT- and C-arm-based navigation at the thoracic and lumbar spine. With CT based navigation, 82 pedicle screws were consecutively inserted, 53 into the thoracic and 29 into the lumbar spine. Seven (13%) perforations were detected at the thoracic spine and two (7%) at the lumbar spine. Additionally, minor perforations below the thread depth were seen in six (11%) thoracic and in two (7%) lumbar instrumentation. With C-arm-based navigation, 74 screws were consecutively placed into 38 thoracic and 36 lumbar pedicles. Perforations were noted in ten (26%) thoracic and four (11%) lumbar implants. Minor perforations were observed in another nine (24%) thoracic and ten (28%) lumbar pedicles. The observer-independent and standardized in vitro study based on a transpedicular 3.2-mm drill hole aiming a 4-mm steel ball in a plastic bone model showed pedicle perforations of the drill canal only in thoracic vertebrae, 1 of 15 in CT-based and 3 of 15 in C-arm navigation. The quantitative calculation of the smallest distance between the central line through the drill canal and the center of the steel ball resulted in 1.4 mm (0.5-4.8 mm) for the CT-based navigation at the thoracic spine and in 1.8 mm (0.5-3 mm) at the lumbar spine. For the C-arm based navigation the distance was 2.6 mm (0.9-4.8 mm) for the thoracic spine and 2 mm (1.2-3 mm) for the lumbar spine. In our opinion, the clinical results of the comparative accuracy of CT- and C-arm-based navigation in the present study showed moderate advantages of the CT-based technique in the thoracic spine, whereas CT- and C-arm based navigation had comparable perforation rates at the lumbar pedicle. The results of the experimental study correlated with the clinical data.

  7. Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy.

    PubMed

    Theologis, A A; Burch, S; Pekmezci, M

    2016-05-01

    We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (sd) 1922) than during fluoroscopy (11.9 mRem sd 14.8) (p < 0.01). O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696-702. ©2016 The British Editorial Society of Bone & Joint Surgery.

  8. Treatment of recurrent patellar dislocation via knee arthroscopy combined with C-arm fluoroscopy and reconstruction of the medial patellofemoral ligament.

    PubMed

    Li, Li; Wang, Hongbo; He, Yun; Si, Yu; Zhou, Hongyu; Wang, Xin

    2018-06-01

    Recurrent patellar dislocations were treated via knee arthroscopy combined with C-arm fluoroscopy, and reconstruction of the medial patellofemoral ligaments. Between October 2013 and March 2017, 52 cases of recurrent patellar dislocation [27 males and 25 females; age, 16-47 years (mean, 21.90 years)] were treated. Arthroscopic exploration was performed and patellofemoral joint cartilage injuries were repaired. It was subsequently determined whether it was necessary to release the lateral patellofemoral support belt. Pre-operative measurements were used to decide whether tibial tubercle osteotomy was required. Medial patellofemoral ligaments were reconstructed using autologous semitendinosus tendons. Smith and Nephew model 3.5 line anchors were used to double-anchor the medial patellofemoral margin. On the femoral side, the medial patellofemoral ligament was fixed using 7-cm, absorbable, interfacial compression screws. All cases were followed for 1-40 months (average, 21 months). The Q angle, tibial tuberosity trochlear groove distance, Insall-Salvati index, patellofemoral angle, lateral patellofemoral angle and lateral shift were evaluated on X-Ray images using the picture archiving and communication system. Subjective International Knee Documentation Committee (IKDC) knee joint functional scores and Lysholm scores were recorded. Post-operative fear was absent, and no patellar re-dislocation or re-fracture was noted during follow-up. At the end of follow-up, the patellofemoral angle (0.22±4.23°), lateral patellofemoral angle (3.44±1.30°), and lateral shift (0.36+0.14°) differed significantly from the pre-operative values (all, P<0.05). Furthermore, IKDC and Lysholm scores (87.84+3.74 and 87.48+3.35, respectively) differed significantly from the pre-operative values (both, P<0.05). These findings suggest that, in the short term, recurrent patellar dislocation treatment via knee arthroscopy combined with C-arm fluoroscopy and reconstruction of the medial patellofemoral ligament was effective.

  9. Factors affecting residency rank-listing: a Maxdiff survey of graduating Canadian medical students.

    PubMed

    Wang, Tao; Wong, Benson; Huang, Alexander; Khatri, Prateek; Ng, Carly; Forgie, Melissa; Lanphear, Joel H; O'Neill, Peter J

    2011-08-25

    In Canada, graduating medical students consider many factors, including geographic, social, and academic, when ranking residency programs through the Canadian Residency Matching Service (CaRMS). The relative significance of these factors is poorly studied in Canada. It is also unknown how students differentiate between their top program choices. This survey study addresses the influence of various factors on applicant decision making. Graduating medical students from all six Ontario medical schools were invited to participate in an online survey available for three weeks prior to the CaRMS match day in 2010. Max-Diff discrete choice scaling, multiple choice, and drop-list style questions were employed. The Max-Diff data was analyzed using a scaled simple count method. Data for how students distinguish between top programs was analyzed as percentages. Comparisons were made between male and female applicants as well as between family medicine and specialist applicants; statistical significance was determined by the Mann-Whitney test. In total, 339 of 819 (41.4%) eligible students responded. The variety of clinical experiences and resident morale were weighed heavily in choosing a residency program; whereas financial incentives and parental leave attitudes had low influence. Major reasons that applicants selected their first choice program over their second choice included the distance to relatives and desirability of the city. Both genders had similar priorities when selecting programs. Family medicine applicants rated the variety of clinical experiences more importantly; whereas specialty applicants emphasized academic factors more. Graduating medical students consider program characteristics such as the variety of clinical experiences and resident morale heavily in terms of overall priority. However, differentiation between their top two choice programs is often dependent on social/geographic factors. The results of this survey will contribute to a better understanding of the CaRMS decision making process for both junior medical students and residency program directors.

  10. Super-global distortion correction for a rotational C-arm x-ray image intensifier.

    PubMed

    Liu, R R; Rudin, S; Bednarek, D R

    1999-09-01

    Image intensifier (II) distortion changes as a function of C-arm rotation angle because of changes in the orientation of the II with the earth's or other stray magnetic fields. For cone-beam computed tomography (CT), distortion correction for all angles is essential. The new super-global distortion correction consists of a model to continuously correct II distortion not only at each location in the image but for every rotational angle of the C arm. Calibration bead images were acquired with a standard C arm in 9 in. II mode. The super-global (SG) model is obtained from the single-plane global correction of the selected calibration images with given sampling angle interval. The fifth-order single-plane global corrections yielded a residual rms error of 0.20 pixels, while the SG model yielded a rms error of 0.21 pixels, a negligibly small difference. We evaluated the accuracy dependence of the SG model on various factors, such as the single-plane global fitting order, SG order, and angular sampling interval. We found that a good SG model can be obtained using a sixth-order SG polynomial fit based on the fifth-order single-plane global correction, and that a 10 degrees sampling interval was sufficient. Thus, the SG model saves processing resources and storage space. The residual errors from the mechanical errors of the x-ray system were also investigated, and found comparable with the SG residual error. Additionally, a single-plane global correction was done in the cylindrical coordinate system, and physical information about pincushion distortion and S distortion were observed and analyzed; however, this method is not recommended due to a lack of calculational efficiency. In conclusion, the SG model provides an accurate, fast, and simple correction for rotational C-arm images, which may be used for cone-beam CT.

  11. Influence of grid control and object detection on radiation exposure and image quality using mobile C-arms - first results.

    PubMed

    Gosch, D; Ratzmer, A; Berauer, P; Kahn, T

    2007-09-01

    The objective of this study was to examine the extent to which the image quality on mobile C-arms can be improved by an innovative exposure rate control system (grid control). In addition, the possible dose reduction in the pulsed fluoroscopy mode using 25 pulses/sec produced by automatic adjustment of the pulse rate through motion detection was to be determined. As opposed to conventional exposure rate control systems, which use a measuring circle in the center of the field of view, grid control is based on a fine mesh of square cells which are overlaid on the entire fluoroscopic image. The system uses only those cells for exposure control that are covered by the object to be visualized. This is intended to ensure optimally exposed images, regardless of the size, shape and position of the object to be visualized. The system also automatically detects any motion of the object. If a pulse rate of 25 pulses/sec is selected and no changes in the image are observed, the pulse rate used for pulsed fluoroscopy is gradually reduced. This may decrease the radiation exposure. The influence of grid control on image quality was examined using an anthropomorphic phantom. The dose reduction achieved with the help of object detection was determined by evaluating the examination data of 146 patients from 5 different countries. The image of the static phantom made with grid control was always optimally exposed, regardless of the position of the object to be visualized. The average dose reduction when using 25 pulses/sec resulting from object detection and automatic down-pulsing was 21 %, and the maximum dose reduction was 60 %. Grid control facilitates C-arm operation, since optimum image exposure can be obtained independently of object positioning. Object detection may lead to a reduction in radiation exposure for the patient and operating staff.

  12. A line fiducial method for geometric calibration of cone-beam CT systems with diverse scan trajectories

    NASA Astrophysics Data System (ADS)

    Jacobson, M. W.; Ketcha, M. D.; Capostagno, S.; Martin, A.; Uneri, A.; Goerres, J.; De Silva, T.; Reaungamornrat, S.; Han, R.; Manbachi, A.; Stayman, J. W.; Vogt, S.; Kleinszig, G.; Siewerdsen, J. H.

    2018-01-01

    Modern cone-beam CT systems, especially C-arms, are capable of diverse source-detector orbits. However, geometric calibration of these systems using conventional configurations of spherical fiducials (BBs) may be challenged for novel source-detector orbits and system geometries. In part, this is because the BB configurations are designed with careful forethought regarding the intended orbit so that BB marker projections do not overlap in projection views. Examples include helical arrangements of BBs (Rougee et al 1993 Proc. SPIE 1897 161-9) such that markers do not overlap in projections acquired from a circular orbit and circular arrangements of BBs (Cho et al 2005 Med. Phys. 32 968-83). As a more general alternative, this work proposes a calibration method based on an array of line-shaped, radio-opaque wire segments. With this method, geometric parameter estimation is accomplished by relating the 3D line equations representing the wires to the 2D line equations of their projections. The use of line fiducials simplifies many challenges with fiducial recognition and extraction in an orbit-independent manner. For example, their projections can overlap only mildly, for any gantry pose, as long as the wires are mutually non-coplanar in 3D. The method was tested in application to circular and non-circular trajectories in simulation and in real orbits executed using a mobile C-arm prototype for cone-beam CT. Results indicated high calibration accuracy, as measured by forward and backprojection/triangulation error metrics. Triangulation errors on the order of microns and backprojected ray deviations uniformly less than 0.2 mm were observed in both real and simulated orbits. Mean forward projection errors less than 0.1 mm were observed in a comprehensive sweep of different C-arm gantry angulations. Finally, successful integration of the method into a CT imaging chain was demonstrated in head phantom scans.

  13. The Canadian Urology Fair: a model for minimizing the financial and academic costs of the residency selection process.

    PubMed

    Grober, Ethan D; Matsumoto, Edward D; Jewett, Michael A S; Chin, Joseph L

    2003-12-01

    In 1994, the Canadian urology residency training programs designed the "Canadian Urology Fair"--a single-site (Toronto, Ont.), 1-day fair to conduct the personal interview portion of the residency selection process. The objective of the current study was to evaluate the success of the Urology Fair in achieving its original goals of decreasing the financial burden and minimizing time away from medical training for applicants and faculty. Both candidates and Canadian urology training programs were surveyed regarding the financial and academic costs (days absent) of attending the 2001 Urology Fair. Data from the 2001 Canadian Resident Matching Service (CaRMS) was used to compare the financial and academic costs of attending personal interviews incurred by candidates declaring urology as their first-choice discipline to candidates interviewing with other surgical specialties throughout Canada. Financial costs incurred by candidates to attend the Urology Fair (mean Can dollar 367) were significantly lower than candidates' estimated costs of attending on-site interviews at the individual programs (mean Can dollar 2065). The financial costs of attending personal interviews by CaRMS applicants declaring urology as their first-choice discipline (mean Can dollar 2002) were significantly lower than the costs incurred by applicants interviewing with other surgical disciplines (mean Can dollar 2744). Financial costs to urology programs attending the fair (mean Can dollar 1931) were not significantly greater than the programs' estimated costs of conducting on-site interviews at their respective program locations (mean Can dollar 1825). Days absent from medical school to attend interviews were significantly lower among CaRMS applicants declaring urology as their first-choice discipline (3 d) compared with applicants who interviewed with other surgical specialties (9.1 d). The Canadian Urology Fair represents an innovative and efficient method for residency programs to conduct the personal interview portion of the residency selection process and should serve as a model for making the interview process less expensive and time-consuming for both candidates and faculty.

  14. Trends in matching to urology residency in Canada: are we becoming noncompetitive?

    PubMed

    Melnyk, Megan; Nelson, Hilary; Mickelson, Jennifer; Macneily, Andrew E

    2013-01-01

    Urology is perceived as a competitive specialty choice. Declining undergraduate exposure and the preference for "lifestyle specialties" may jeopardize urology's popularity. Our objective was to assess trends in application and matching rates to urology compared with other surgical specialties. We reviewed data collected by Canadian Residency Matching Service (CaRMS) and the Canadian Post-MD Education Registry since expansion in Canadian medical school enrollment began (2002-2011). The following were examined: applicant preference, number of positions, gender patterns, and match results. "Surgery" included general surgery, orthopedics, plastics, ENT, and urology. From 2002 to 2011 CaRMS applicants increased from 1117 to 2528 (126%). The number of applicants selecting surgery first increased from 178 to 338(90%). The number of surgery positions increased from 138 to 275 (100%). Urology positions increased from 15 to 31 (113%). Applicants to urology increased only 40% (30-42). The proportion of all CARMs applicants selecting urology as their first choice decreased from 2.7% (30) to 1.7% (42). The ratio of first choice urology applicants to positions decreased from 2 to 1.35. The probability of matching urology as first choice increased from 50% to 76%. Female medical graduates increased from 51% to 58%. The female applicants selecting surgery first increased from 21% (49) to 41% (173). In contrast, females selecting urology first rose from 13% (4) to 17% (7). Urology in Canada is becoming less competitive. Residency positions have doubled since 2002 whereas the number of applicants remains static. This trend was not reflected in other surgical specialities. Factors accounting for this may include poor undergraduate exposure, demand for specialties with controllable lifestyles, gender shifts in undergraduate medicine, and lack of role models. The need for undergraduate exposure to urology and vetting numbers of residency positions remains a matter of paramount importance. Copyright © 2013 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  15. Comparison of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease with Flat-Panel Detectors on Mobile C-arm versus Fixed Systems.

    PubMed

    Guillou, Marie; Maurel, Blandine; Necib, Hatem; Vent, Pierre-Alexandre; Costargent, Alain; Chaillou, Philippe; Gouëffic, Yann; Kaladji, Adrien

    2018-02-01

    Flat-panel detectors on mobile C-arm (MC-arm) systems are currently challenging fixed C-arm (FC-arm) systems used in hybrid operating rooms. MC-arm systems offer an alternative to FC-arm systems in the endovascular treatment of peripheral arterial disease (PAD) but their efficiency has not been evaluated comparatively. Two series of patients undergoing arteriography with intention to treat were included. Each series consisted of 2 nonrandomized groups: an MC-arm group and an FC-arm group. Series 1 evaluated exposure to the patient (MC-arm, n = 113; FC-arm, n = 206) while series 2 evaluated exposure to patients and also health care personnel (MC-arm, n = 24; FC-arm, n = 76). The primary end points for evaluating exposure were air kerma (AK, in mGy) for patients and effective dose for health care personnel (in μSv). After adjustment for the effect of body mass index (analysis of covariance test), AK was found to be lower in the MC-arm group than in the FC-arm group (124.1 ± 142 vs. 173.3 ± 248.7, P = 0.025). There was no difference between the groups with regard to effective dose recorded for senior surgeons or for operating room nurses. However, a higher effective dose was recorded by the MC-arm group external dosimeter for the trainee resident and for nurse anesthetists. In endovascular treatment of lower limb PAD, use of an FC-arm system is associated with more radiation exposure to the patient than an MC-arm system. However, this type of imaging system does not appear to affect exposure to health care personnel. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. A new transform for the analysis of complex fractionated atrial electrograms

    PubMed Central

    2011-01-01

    Background Representation of independent biophysical sources using Fourier analysis can be inefficient because the basis is sinusoidal and general. When complex fractionated atrial electrograms (CFAE) are acquired during atrial fibrillation (AF), the electrogram morphology depends on the mix of distinct nonsinusoidal generators. Identification of these generators using efficient methods of representation and comparison would be useful for targeting catheter ablation sites to prevent arrhythmia reinduction. Method A data-driven basis and transform is described which utilizes the ensemble average of signal segments to identify and distinguish CFAE morphologic components and frequencies. Calculation of the dominant frequency (DF) of actual CFAE, and identification of simulated independent generator frequencies and morphologies embedded in CFAE, is done using a total of 216 recordings from 10 paroxysmal and 10 persistent AF patients. The transform is tested versus Fourier analysis to detect spectral components in the presence of phase noise and interference. Correspondence is shown between ensemble basis vectors of highest power and corresponding synthetic drivers embedded in CFAE. Results The ensemble basis is orthogonal, and efficient for representation of CFAE components as compared with Fourier analysis (p ≤ 0.002). When three synthetic drivers with additive phase noise and interference were decomposed, the top three peaks in the ensemble power spectrum corresponded to the driver frequencies more closely as compared with top Fourier power spectrum peaks (p ≤ 0.005). The synthesized drivers with phase noise and interference were extractable from their corresponding ensemble basis with a mean error of less than 10%. Conclusions The new transform is able to efficiently identify CFAE features using DF calculation and by discerning morphologic differences. Unlike the Fourier transform method, it does not distort CFAE signals prior to analysis, and is relatively robust to jitter in periodic events. Thus the ensemble method can provide a useful alternative for quantitative characterization of CFAE during clinical study. PMID:21569421

  17. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment.

    PubMed

    Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas; Pal, Saikat; McWalter, Emily J; Beaupré, Gary S; Gold, Garry E; Fahrig, Rebecca

    2014-06-01

    A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjects in vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. A 2D Euclidean distance-based metric of subjects' motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.

  18. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas

    2014-06-15

    Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo undermore » weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. Conclusions: The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.« less

  19. Large-amplitude ULF waves at high latitudes

    NASA Astrophysics Data System (ADS)

    Guido, T.; Tulegenov, B.; Streltsov, A. V.

    2014-11-01

    We present results from the statistical study of ULF waves detected by the fluxgate magnetometer in Gakona, Alaska during several experimental campaigns conducted at the High Frequency Active Auroral Research Program (HAARP) facility in years 2011-2013. We analyzed frequencies of ULF waves recorded during 26 strongly disturbed geomagnetic events (substorms) and compared them with frequencies of ULF waves detected during magnetically quiet times. Our analysis demonstrates that the frequency of the waves carrying most of the power in almost all these events is less than 1 mHz. We also analyzed data from the ACE satellite, measuring parameters of the solar wind in the L1 Lagrangian point between Earth and Sun, and found that in several occasions there is a strong correlation between oscillations of the magnetic field in the solar wind and oscillations detected on the ground. We also found several cases when there is no correlation between signals detected on ACE and on the ground. This finding suggests that these frequencies correspond to the fundamental eigenfrequency of the coupled magnetosphere-ionosphere system, and the amplitude of these waves can reach significant magnitude when the system is driven by the external driver (for example, the solar wind) with this particular frequency. When the frequency of the driver does not match the frequency of the system, the waves still are observed, but their amplitudes are much smaller.

  20. BEHAVIORAL CHARACTERISTICS OF DANGEROUS DRIVERS—Importance of Correction

    PubMed Central

    Friesen, Arnold R.; Schube, Purcell G.

    1960-01-01

    Studies of accident-prone drivers emphasize the frequency of unstable, aggressive or antisocial personalities expressing themselves through the automobile as a real and a symbolic weapon. Such expressions may be voluntary or unconscious and may also lead a driver to injure himself or seek injury from others. Because of the great public danger from such drivers, it is urgent that judges and enforcers of the law recognize the psychic motivation in habitual violation and withhold driving privileges from violators until a psychic adjustment has been made. Physicians can contribute in gaining acceptance for this attitude of enforcement, and in setting up adequate psychiatric procedures for correction of violators. PMID:13825207

  1. Driver responses to differing urban work zone configurations.

    PubMed

    Morgan, J F; Duley, A R; Hancock, P A

    2010-05-01

    This study reports the results of a simulator-based assessment of driver response to two different urban highway work zone configurations. One configuration represented an existing design which was contrasted with a second configuration that presented a reduced taper length prototype work zone design. Twenty-one drivers navigated the two different work zones in two different conditions, one with and one without a lead vehicle; in this case a bus. Measures of driver speed, braking, travel path, and collision frequency were recorded. Drivers navigated significantly closer to the boundary of the work area in the reduced taper length design. This proximity effect was moderated by the significant interaction between lead vehicle and taper length and such interactive effects were also observed for driver speed at the end of the work zone and the number of collisions observed within the work zone itself. These results suggest that reduced taper length poses an increase in risk to both drivers and work zone personnel, primarily when driver anticipation is reduced by foreshortened viewing distances. Increase in such risk is to a degree offset by the reduction of overall exposure to the work zone that a foreshortened taper creates. The benefits and limitations to a simulation-based approach to the assessment and prediction of driver behavior in different work zone configurations are also discussed. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  2. Age-Related Differences in Vehicle Control and Eye Movement Patterns at Intersections: Older and Middle-Aged Drivers

    PubMed Central

    Yamani, Yusuke; Horrey, William J.; Liang, Yulan; Fisher, Donald L.

    2016-01-01

    Older drivers are at increased risk of intersection crashes. Previous work found that older drivers execute less frequent glances for detecting potential threats at intersections than middle-aged drivers. Yet, earlier work has also shown that an active training program doubled the frequency of these glances among older drivers, suggesting that these effects are not necessarily due to age-related functional declines. In light of findings, the current study sought to explore the ability of older drivers to coordinate their head and eye movements while simultaneously steering the vehicle as well as their glance behavior at intersections. In a driving simulator, older (M = 76 yrs) and middle-aged (M = 58 yrs) drivers completed different driving tasks: (1) travelling straight on a highway while scanning for peripheral information (a visual search task) and (2) navigating intersections with areas potential hazard. The results replicate that the older drivers did not execute glances for potential threats to the sides when turning at intersections as frequently as the middle-aged drivers. Furthermore, the results demonstrate costs of performing two concurrent tasks, highway driving and visual search task on the side displays: the older drivers performed more poorly on the visual search task and needed to correct their steering positions more compared to the middle-aged counterparts. The findings are consistent with the predictions and discussed in terms of a decoupling hypothesis, providing an account for the effects of the active training program. PMID:27736887

  3. Analysis of high-frequency water quality data collected during a cyanoHAB event on an inland, multi-use reservoir

    EPA Science Inventory

    We describe here an effort to use high frequency data collected from online, continuous monitors coupled with field collected data to describe the temporal relationship between suspected HAB drivers and observed cyanoHABs and cyanotoxin production to provide insight on the necess...

  4. Survey of health and licensing policies for taxi drivers in Singapore, Hong Kong and Australia: a perspective from evidence on older drivers.

    PubMed

    Chan, M L; Gustafsson, L; Liddle, J

    2010-12-01

    With an ageing population, policy makers need to balance active ageing needs with older driver safety. In 2009, a survey of licensing policies for taxi drivers in Singapore, Hong Kong and Australia was undertaken for an evidence-based review of policies. Licensing requirements collected using semi-structured questionnaires were compared descriptively and with evidence from licensing policies on older drivers. All the regions used medical certifications with vision screening. The frequency of medical certification varied according to the renewal cycle and age. Medical guidelines on fitness to drive were available in Australia and Singapore. Legislation for self-reporting of medical conditions by drivers existed in Australia and Hong Kong. Legislation for reporting at-risk drivers by doctors was limited to two Australian states. There were differences in the minimum age and driving experience criteria, the use of practical training, written and English tests, age-based screening, mandatory retirement age, refresher courses, off- and on-road tests. Medical screening for at-risk drivers remains crucial. Age-based mandatory retirement policy at 73 years in Singapore is contrary to evidence-based practice. The lack of legislation for self-reporting of illness by drivers, the high minimum age criteria and therapy driving assessments for healthy taxi drivers are also unique to Singapore. There was stricter age-based relicensing from the age of 65 years in some Australian states and in Singapore. Continuing education for doctors, multi-tier screening for at-risk drivers and licensing policy changes are indicated.

  5. Analysis of Driver Evasive Maneuvering Prior to Intersection Crashes Using Event Data Recorders.

    PubMed

    Scanlon, John M; Kusano, Kristofer D; Gabler, Hampton C

    2015-01-01

    Intersection crashes account for over 4,500 fatalities in the United States each year. Intersection Advanced Driver Assistance Systems (I-ADAS) are emerging vehicle-based active safety systems that have the potential to help drivers safely navigate across intersections and prevent intersection crashes and injuries. The performance of an I-ADAS is expected to be highly dependent upon driver evasive maneuvering prior to an intersection crash. Little has been published, however, on the detailed evasive kinematics followed by drivers prior to real-world intersection crashes. The objective of this study was to characterize the frequency, timing, and kinematics of driver evasive maneuvers prior to intersection crashes. Event data recorders (EDRs) downloaded from vehicles involved in intersection crashes were investigated as part of NASS-CDS years 2001 to 2013. A total of 135 EDRs with precrash vehicle speed and braking application were downloaded to investigate evasive braking. A smaller subset of 59 EDRs that collected vehicle yaw rate was additionally analyzed to investigate evasive steering. Each vehicle was assigned to one of 3 precrash movement classifiers (traveling through the intersection, completely stopped, or rolling stop) based on the vehicle's calculated acceleration and observed velocity profile. To ensure that any significant steering input observed was an attempted evasive maneuver, the analysis excluded vehicles at intersections that were turning, driving on a curved road, or performing a lane change. Braking application at the last EDR-recorded time point was assumed to indicate evasive braking. A vehicle yaw rate greater than 4° per second was assumed to indicate an evasive steering maneuver. Drivers executed crash avoidance maneuvers in four-fifths of intersection crashes. A more detailed analysis of evasive braking frequency by precrash maneuver revealed that drivers performing complete or rolling stops (61.3%) braked less often than drivers traveling through the intersection without yielding (79.0%). After accounting for uncertainty in the timing of braking and steering data, the median evasive braking time was found to be between 0.5 to 1.5 s prior to impact, and the median initial evasive steering time was found to occur between 0.5 and 0.9 s prior to impact. The median average evasive braking deceleration for all cases was found to be 0.58 g. The median of the maximum evasive vehicle yaw rates was found to be 8.2° per second. Evasive steering direction was found to be most frequently in the direction of travel of the approaching vehicle. The majority of drivers involved in intersection crashes were alert enough to perform an evasive action. Most drivers used a combination of steering and braking to avoid a crash. The average driver attempted to steer and brake at approximately the same time prior to the crash.

  6. Comparison of human driver dynamics in simulators with complex and simple visual displays and in an automobile on the road

    NASA Technical Reports Server (NTRS)

    Mcruer, D. T.; Klein, R. H.

    1975-01-01

    As part of a comprehensive program exploring driver/vehicle system response in lateral steering tasks, driver/vehicle system describing functions and other dynamic data have been gathered in several milieu. These include a simple fixed base simulator with an elementary roadway delineation only display; a fixed base statically operating automobile with a terrain model based, wide angle projection system display; and a full scale moving base automobile operating on the road. Dynamic data with the two fixed base simulators compared favorably, implying that the impoverished visual scene, lack of engine noise, and simplified steering wheel feel characteristics in the simple simulator did not induce significant driver dynamic behavior variations. The fixed base vs. moving base comparisons showed substantially greater crossover frequencies and phase margins on the road course.

  7. Performance of a 100V Half-Bridge MOSFET Driver, Type MIC4103, Over a Wide Temperature Range

    NASA Technical Reports Server (NTRS)

    Patterson, Richard L.; Hammoud, Ahmad

    2011-01-01

    The operation of a high frequency, high voltage MOSFET (metal-oxide semiconductor field-effect transistors) driver was investigated over a wide temperature regime that extended beyond its specified range. The Micrel MIC4103 is a 100V, non-inverting, dual driver that is designed to independently drive both high-side and low-side N-channel MOSFETs. It features fast propagation delay times and can drive 1000 pF load with 10ns rise times and 6 ns fall times [1]. The device consumes very little power, has supply under-voltage protection, and is rated for a -40 C to +125 C junction temperature range. The floating high-side driver of the chip can sustain boost voltages up to 100 V. Table I shows some of the device manufacturer s specification.

  8. Self-assessed driving behaviors associated with age among middle-aged and older adults in Japan.

    PubMed

    Arai, Asuna; Arai, Yumiko

    2015-01-01

    With the increasing number of older drivers, road traffic safety is an urgent public health issue. It is not easy for older drivers or their relatives to detect early signs of dangerous driving behaviors. We examine the types of driving behavior that increase in frequency with age. We surveyed people aged 40 and over among the general public in Japan using a self-administered questionnaire on sociodemographic factors, driving status, frequency of driving, 12-items on physical symptoms possibly related to driving performance, and 28-items on driving behaviors. Multiple logistic regression models were used to estimate the odds ratios (OR) of occurrence of each of the 28 driving behaviors for a 5-year increase in age. Significant associations with a 5-year increase in age after adjusting for confounding factors were found for the following directly unsafe driving behaviors: (1) little or no sign of attempts to avoid dangerous situations (OR for a 5-year increase in age=1.38, 95% CI: 1.18-1.63); (2) lack of attention to other people and cars (1.33, 1.12-1.60); (3) improper maneuvering around curves (1.33, 1.09-1.65); and (4) improper or no turn signals (1.33, 1.06-1.69). Information about these driving behaviors should be given to drivers and their stakeholders and used to caution participants when implementing educational programs for older drivers. Self-assessment of driving ability in older drivers provides useful information to raise awareness of their driving performance. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. A multispacecraft event study of Pc5 ultralow-frequency waves in the magnetosphere and their external drivers

    DOE PAGES

    Wang, Chih-Ping; Thorne, Richard; Liu, Terry Z.; ...

    2017-05-09

    We investigate a quiet time event of magnetospheric Pc5 ultralow-frequency (ULF) waves and their likely external drivers using multiple spacecraft observations. Enhancements of electric and magnetic field perturbations in two narrow frequency bands, 1.5–2 mHz and 3.5–4 mHz, were observed over a large radial distance range from r ~ 5 to 11 RE. During the first half of this event, perturbations were mainly observed in the transverse components and only in the 3.5–4 mHz band. In comparison, enhancements were stronger during the second half in both transverse and compressional components and in both frequency bands. No indication of field linemore » resonances was found for these magnetic field perturbations. Perturbations in these two bands were also observed in the magnetosheath, but not in the solar wind dynamic pressure perturbations. For the first interval, good correlations between the flow perturbations in the magnetosphere and magnetosheath and an indirect signature for Kelvin-Helmholtz (K-H) vortices suggest K-H surface waves as the driver. For the second interval, good correlations are found between the magnetosheath dynamic pressure perturbations, magnetopause deformation, and magnetospheric waves, all in good correspondence to interplanetary magnetic field (IMF) discontinuities. The characteristics of these perturbations can be explained by being driven by foreshock perturbations resulting from these IMF discontinuities. This event shows that even during quiet periods, K-H-unstable magnetopause and ion foreshock perturbations can combine to create a highly dynamic magnetospheric ULF wave environment« less

  10. A multispacecraft event study of Pc5 ultralow-frequency waves in the magnetosphere and their external drivers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chih-Ping; Thorne, Richard; Liu, Terry Z.

    We investigate a quiet time event of magnetospheric Pc5 ultralow-frequency (ULF) waves and their likely external drivers using multiple spacecraft observations. Enhancements of electric and magnetic field perturbations in two narrow frequency bands, 1.5–2 mHz and 3.5–4 mHz, were observed over a large radial distance range from r ~ 5 to 11 RE. During the first half of this event, perturbations were mainly observed in the transverse components and only in the 3.5–4 mHz band. In comparison, enhancements were stronger during the second half in both transverse and compressional components and in both frequency bands. No indication of field linemore » resonances was found for these magnetic field perturbations. Perturbations in these two bands were also observed in the magnetosheath, but not in the solar wind dynamic pressure perturbations. For the first interval, good correlations between the flow perturbations in the magnetosphere and magnetosheath and an indirect signature for Kelvin-Helmholtz (K-H) vortices suggest K-H surface waves as the driver. For the second interval, good correlations are found between the magnetosheath dynamic pressure perturbations, magnetopause deformation, and magnetospheric waves, all in good correspondence to interplanetary magnetic field (IMF) discontinuities. The characteristics of these perturbations can be explained by being driven by foreshock perturbations resulting from these IMF discontinuities. This event shows that even during quiet periods, K-H-unstable magnetopause and ion foreshock perturbations can combine to create a highly dynamic magnetospheric ULF wave environment« less

  11. Comparison of Visual Status of Iranian Military and Commercial Drivers

    PubMed Central

    Ghasemi, Mohammad; Hoseini Yazdi, Seyed Hosein; Heravian, Javad; Jafarzadehpur, Ebrahim; Rezaee, Maryam

    2015-01-01

    Background: There is no legal requirement for Iranian military truck drivers to undergo regular visual checkups as compared to commercial truck drivers. Objectives: This study aimed to evaluate the impact of drivers’ visual checkups by comparing the visual function of Iranian military and commercial truck drivers. Patients and Methods: In this comparative cross-sectional study, two hundred military and 200 commercial truck drivers were recruited and their Visual Acuity (VA), Visual Field (VF), color vision and Contrast Sensitivity (CS) were assessed and compared using the Snellen chart, confrontation screening method, D15 test and Pelli-Robson letter chart, respectively. A questionnaire regarding driving exposure and history of motor-vehicle crashes (MVCs) was also filled by drivers. Results were analyzed using an independent samples t-test, one-way ANOVA (assessing difference in number of MVCs across different age groups), chi-square test and Pearson correlation at statistical significance level of P < 0.05. Results: Mean age was 41.6 ± 9.2 for the military truck drivers and 43.4 ± 10.9 for commercial truck drivers (P > 0.05). No significant difference between military and commercial drivers was found in terms of driving experience, number of MVCs, binocular VA, frequency of color vision defects and CS scores. In contrast, the last ocular examination was significantly earlier in military drivers than commercial drivers (P < 0.001). In addition, 4% of military drivers did not meet the national standards to drive as opposed to 2% of commercial drivers. There was a significant but weak correlation between binocular VA and age (r = 0.175, P < 0.001). However, CS showed a significantly moderate correlation with age (r = -0.488, P < 0.001). Conclusions: The absence of legal requirement for regular eye examination in military drivers caused the incompetent drivers to be missed in contrast to commercial drivers. The need for scientific revision of VA standard for Iranian drivers is also discussed. The CS measurement in visual checkups of older drivers deserves to be investigated more thoroughly. PMID:26023333

  12. Frequency tripling of convergent beam employing crystals tiling in large-aperture high-energy laser facilities

    NASA Astrophysics Data System (ADS)

    Wang, Junhua; Li, Dazhen; Wang, Bo; Yang, Jing; Yang, Houwen; Wang, Xiaoqian; Cheng, Wenyong

    2017-11-01

    In inertial confinement fusion, ultraviolet laser damage of the fused silica lens is an important limiting factor for load capability of the laser driver. To solve this problem, a new configuration of frequency tripling is proposed in this paper. The frequency tripling crystal is placed on downstream of the focusing lens, thus sum frequency generation of fundamental frequency light and doubling frequency light occurs in the beam convergence path. The focusing lens is only irradiated by fundamental light and doubling frequency lights. Thus, its damage threshold will increase. LiB3O5 (LBO) crystals are employed as frequency tripling crystals for its larger acceptance angle and higher damage threshold than KDP/DKDP crystals'. With the limitation of acceptance angle and crystal growth size are taken into account, the tiling scheme of LBO crystals is proposed and designed optimally to adopt to the total convergence angle of 36.0 mrad. Theoretical results indicate that 3 LBO crystals titling with different cutting angles in θ direction can meet the phase matching condition. Compared with frequency tripling of parallel beam using one LBO crystal, 83.8% (93.1% with 5 LBO crystals tiling) of the frequency tripling conversion efficiency can be obtained employing this new configuration. The results of a principle experiment also support this scheme. By employing this new design, not only the load capacity of a laser driver will be significantly improved, but also the fused silica lens can be changed to K9 glass lens which has the mature technology and low cost.

  13. Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources

    NASA Technical Reports Server (NTRS)

    McAndrew, Brendan; Cooper, John; Arecchi, Angelo; McKee, Greg; Durell, Christopher

    2012-01-01

    Stable high radiance in visible and near-ultraviolet wavelengths is desirable for radiometric calibration sources. In this work, newly available electrodeless radio-frequency (RF) driven plasma light sources were combined with research grade, low-noise power supplies and coupled to an integrating sphere to produce a uniform radiance source. The stock light sources consist of a 28 VDC power supply, RF driver, and a resonant RF cavity. The RF cavity includes a small bulb with a fill gas that is ionized by the electric field and emits light. This assembly is known as the emitter. The RF driver supplies a source of RF energy to the emitter. In commercial form, embedded electronics within the RF driver perform a continual optimization routine to maximize energy transfer to the emitter. This optimization routine continually varies the light output sinusoidally by approximately 2% over a several-second period. Modifying to eliminate this optimization eliminates the sinusoidal variation but allows the output to slowly drift over time. This drift can be minimized by allowing sufficient warm-up time to achieve thermal equilibrium. It was also found that supplying the RF driver with a low-noise source of DC electrical power improves the stability of the lamp output. Finally, coupling the light into an integrating sphere reduces the effect of spatial fluctuations, and decreases noise at the output port of the sphere.

  14. Preliminary design approach for large high precision segmented reflectors

    NASA Technical Reports Server (NTRS)

    Mikulas, Martin M., Jr.; Collins, Timothy J.; Hedgepeth, John M.

    1990-01-01

    A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.

  15. Could Intelligent Speed Adaptation make overtaking unsafe?

    PubMed

    Jamson, Samantha; Chorlton, Kathryn; Carsten, Oliver

    2012-09-01

    This driving simulator study investigated how mandatory and voluntary ISA might affect a driver's overtaking decisions on rural roads, by presenting drivers with a variety of overtaking scenarios designed to evaluate both the frequency and safety of the manoeuvres. In half the overtaking scenarios, ISA was active and in the remainder ISA was switched off. A rural road was modelled with a number of 2+1 road sections, thus allowing drivers a protected overtaking opportunity. The results indicate that drivers became less inclined to initiate an overtaking manoeuvre when the mandatory ISA was active and this was particularly so when the overtaking opportunity was short. In addition to this, when ISA was activated drivers were more likely to have to abandon an overtaking, presumably due to running out of road. They also spent more time in the critical hatched area-a potentially unsafe behaviour. The quality of the overtaking manoeuvre was also affected when mandatory ISA was active, with drivers pulling out and cutting back in more sharply. In contrast, when driving with a voluntary ISA, overtaking behaviour remained mostly unchanged: drivers disengaged the function in approximately 70% of overtaking scenarios. The results of this study suggest that mandatory ISA could affect the safety of overtaking manoeuvres unless coupled with an adaptation period or other driver support functions that support safe overtaking. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Linking mind wandering tendency to risky driving in young male drivers.

    PubMed

    Albert, Derek A; Ouimet, Marie Claude; Jarret, Julien; Cloutier, Marie-Soleil; Paquette, Martin; Badeau, Nancy; Brown, Thomas G

    2018-02-01

    Risky driving is a significant contributor to road traffic crashes, especially in young drivers. Transient mind wandering states, an internal form of distraction, are associated with faster driving, reduced headway distance, slower response times, reduced driver vigilance, and increased crash risk. It is unclear whether a trait tendency to mind wander predicts risky driving, however. Mind wandering is also associated with poor executive control, but whether this capacity moderates the putative link between mind wandering tendency and risky driving is uncertain. The present study tested whether mind wandering tendency predicts risky driving behaviour in young male drivers aged 18-21 (N=30) and whether this relationship is mediated by driver vigilance and moderated by executive control capacity. Mind wandering was measured with the Sustained Attention to Response Task (SART) and the Daydreaming Frequency Scale (DDFS). Risky driving was assessed by mean speed in a driving simulator and driver vigilance was quantified by horizontal eye movements measured with eye tracking. Results showed that greater mind wandering tendency based on SART performance significantly predicts faster mean speed, confirming the main hypothesis. Neither driver vigilance mediated nor executive control capacity moderated this relationship as hypothesized. These findings speak to the complexity of individual differences in mind wandering. Overall, mind wandering tendency is a significant marker of risky driving in young drivers, which could guide the development of targeted interventions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Highly automated driving, secondary task performance, and driver state.

    PubMed

    Merat, Natasha; Jamson, A Hamish; Lai, Frank C H; Carsten, Oliver

    2012-10-01

    A driving simulator study compared the effect of changes in workload on performance in manual and highly automated driving. Changes in driver state were also observed by examining variations in blink patterns. With the addition of a greater number of advanced driver assistance systems in vehicles, the driver's role is likely to alter in the future from an operator in manual driving to a supervisor of highly automated cars. Understanding the implications of such advancements on drivers and road safety is important. A total of 50 participants were recruited for this study and drove the simulator in both manual and highly automated mode. As well as comparing the effect of adjustments in driving-related workload on performance, the effect of a secondary Twenty Questions Task was also investigated. In the absence of the secondary task, drivers' response to critical incidents was similar in manual and highly automated driving conditions. The worst performance was observed when drivers were required to regain control of driving in the automated mode while distracted by the secondary task. Blink frequency patterns were more consistent for manual than automated driving but were generally suppressed during conditions of high workload. Highly automated driving did not have a deleterious effect on driver performance, when attention was not diverted to the distracting secondary task. As the number of systems implemented in cars increases, an understanding of the implications of such automation on drivers' situation awareness, workload, and ability to remain engaged with the driving task is important.

  18. Reliable inverter systems

    NASA Technical Reports Server (NTRS)

    Nagano, S.

    1979-01-01

    Base driver with common-load-current feedback protects paralleled inverter systems from open or short circuits. Circuit eliminates total system oscillation that can occur in conventional inverters because of open circuit in primary transformer winding. Common feedback signal produced by functioning modules forces operating frequency of failed module to coincide with clock drive so module resumes normal operating frequency in spite of open circuit.

  19. Dosimetry in Diagnostic Radiology: A Guide for Meeting JCAHO and ACR requirements and ICRP Recommendations

    DTIC Science & Technology

    1998-01-01

    C-Arms and Digital Fluorscopy ....... ............................. 6 Image Intensifier III) Input Exposure Rates and Exposures...Setup for ESE Measurements in Conventional Radiography .................. 3 Figure 2: Setup tor IP ;R M easurem ents...exposure from dental procedures. An area of dental radiography which has not been well addressed is the dose received during panoramic or panalipse

  20. Nucleolar Reorganization Upon Site-Specific Double-Strand Break Induction.

    PubMed

    Franek, Michal; Kovaříková, Alena; Bártová, Eva; Kozubek, Stanislav

    2016-11-01

    DNA damage response (DDR) in ribosomal genes and mechanisms of DNA repair in embryonic stem cells (ESCs) are less explored nuclear events. DDR in ESCs should be unique due to their high proliferation rate, expression of pluripotency factors, and specific chromatin signature. Given short population doubling time and fast progress through G1 phase, ESCs require a sustained production of rRNA, which leads to the formation of large and prominent nucleoli. Although transcription of rRNA in the nucleolus is relatively well understood, little is known about DDR in this nuclear compartment. Here, we directed formation of double-strand breaks in rRNA genes with I- PpoI endonuclease, and we studied nucleolar morphology, DDR, and chromatin modifications. We observed a pronounced formation of I- PpoI-induced nucleolar caps, positive on BRCA1, NBS1, MDC1, γH2AX, and UBF1 proteins. We showed interaction of nucleolar protein TCOF1 with HDAC1 and TCOF1 with CARM1 after DNA injury. Moreover, H3R17me2a modification mediated by CARM1 was found in I- PpoI-induced nucleolar caps. Finally, we report that heterochromatin protein 1 is not involved in DNA repair of nucleolar caps.

  1. Heterogeneity in Oct4 and Sox2 Targets Biases Cell Fate in 4-Cell Mouse Embryos.

    PubMed

    Goolam, Mubeen; Scialdone, Antonio; Graham, Sarah J L; Macaulay, Iain C; Jedrusik, Agnieszka; Hupalowska, Anna; Voet, Thierry; Marioni, John C; Zernicka-Goetz, Magdalena

    2016-03-24

    The major and essential objective of pre-implantation development is to establish embryonic and extra-embryonic cell fates. To address when and how this fundamental process is initiated in mammals, we characterize transcriptomes of all individual cells throughout mouse pre-implantation development. This identifies targets of master pluripotency regulators Oct4 and Sox2 as being highly heterogeneously expressed between blastomeres of the 4-cell embryo, with Sox21 showing one of the most heterogeneous expression profiles. Live-cell tracking demonstrates that cells with decreased Sox21 yield more extra-embryonic than pluripotent progeny. Consistently, decreasing Sox21 results in premature upregulation of the differentiation regulator Cdx2, suggesting that Sox21 helps safeguard pluripotency. Furthermore, Sox21 is elevated following increased expression of the histone H3R26-methylase CARM1 and is lowered following CARM1 inhibition, indicating the importance of epigenetic regulation. Therefore, our results indicate that heterogeneous gene expression, as early as the 4-cell stage, initiates cell-fate decisions by modulating the balance of pluripotency and differentiation. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Dose and image quality for a cone-beam C-arm CT system.

    PubMed

    Fahrig, Rebecca; Dixon, Robert; Payne, Thomas; Morin, Richard L; Ganguly, Arundhuti; Strobel, Norbert

    2006-12-01

    We assess dose and image quality of a state-of-the-art angiographic C-arm system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) for three-dimensional neuro-imaging at various dose levels and tube voltages and an associated measurement method. Unlike conventional CT, the beam length covers the entire phantom, hence, the concept of computed tomography dose index (CTDI) is not the metric of choice, and one can revert to conventional dosimetry methods by directly measuring the dose at various points using a small ion chamber. This method allows us to define and compute a new dose metric that is appropriate for a direct comparison with the familiar CTDIw of conventional CT. A perception study involving the CATPHAN 600 indicates that one can expect to see at least the 9 mm inset with 0.5% nominal contrast at the recommended head-scan dose (60 mGy) when using tube voltages ranging from 70 kVp to 125 kVp. When analyzing the impact of tube voltage on image quality at a fixed dose, we found that lower tube voltages gave improved low contrast detectability for small-diameter objects. The relationships between kVp, image noise, dose, and contrast perception are discussed.

  3. Visual impairment and road traffic accidents among drivers in Jimma Town, Southwest Ethiopia.

    PubMed

    Biza, Mohamed; Mossie, Andualem; Woldemichael, Kifle; Gelaw, Yeshigeta

    2013-04-01

    Vision play a vital role in driving where good and efficient visual functioning of the driver is essential. Any significant loss of visual function will diminish a driver's ability to operate a motor vehicle safely and will thus contribute to road traffic injury. However, there is little evidence indicating that defects of vision alone cause road traffic accidents. To determine the impact of visual impairment and other factors on road traffic accident among vehicle drivers. A cross-sectional descriptive study was conducted on 249 sampled drivers in Southwest Ethiopia. A pretested interviewer led questionnaire was used for interview and vision tests were done using Snellen's acuity chart and Ishihara pseudo-isochromatic plates. Statistical analyses were performed using SPSS version 16.0. The mean age of drivers was 33.6 years (SD +/- 10.3). The relative frequency of self reported road traffic accident was 15.3%. The prevalence of uncorrected binocular visual impairment was 1.6% and there was a significant association between visual impairment and road traffic accident (P < 0.05). Uncorrected refractive error was seen in 7.6% and 8.8% of drivers in the right and left eyes respectively, and 3.2% of them had vision less than what is required to obtain driving license (visual acuity of 6/12). None of the drivers with refractive errors were wearing appropriate corrections. Color vision impairment was seen in 1.6% of the drivers. A significant proportion (9.6%) of the drivers did not have eye exam for their driving license. Uncorrected binocular visual impairment was strongly associated with road traffic accident. There is need for consistent inspection and screening, strict rules and regulations of licensing and health education for drivers to minimize road traffic accident.

  4. Chinese carless young drivers' self-reported driving behavior and simulated driving performance.

    PubMed

    Zhang, Qian; Jiang, Zuhua; Zheng, Dongpeng; Man, Dong; Xu, Xunnan

    2013-01-01

    Carless young drivers refers to those drivers aged between 18 and 25 years who have a driver's license but seldom have opportunities to practice their driving skills because they do not have their own cars. Due to China's lower private car ownership, many young drivers become carless young drivers after licensure, and the safety issue associated with them has raised great concern in China. This study aims to provide initial insight into the self-reported driving behaviors and simulated driving performance of Chinese carless young drivers. Thirty-three carless young drivers and 32 young drivers with their own cars (as a comparison group) participated in this study. A modified Driver Behavior Questionnaire (DBQ) with a 4-factor structure (errors, violations, attention lapses, and memory lapses) was used to study carless young drivers' self-reported driving behaviors. A simulated driving experiment using a low-cost, fixed-base driving simulator was conducted to measure their simulated driving performance (errors, violations, attention lapses, driving maintenance, reaction time, and accidents). Self-reported DBQ outcomes showed that carless young drivers reported similar errors, more attention lapses, fewer memory lapses, and significantly fewer violation behaviors relative to young drivers with their own cars, whereas simulated driving results revealed that they committed significantly more errors, attention lapses, and violation behaviors than the comparison group. Carless young drivers had a lower ability to maintain the stability of speed and lane position, drove more cautiously approaching and passing through red traffic lights, and committed more accidents during simulated driving. A tendency to speed was not found among carless young drivers; their average speed and speeding frequency were all much lower than that of the comparison group. Lifetime mileage was the only significant predictor of carless young drivers' self-reported violations, simulated violations, speed, and reaction time, whereas no significant predictor was found for young drivers with their own cars. Carless young drivers had poorer driving performance and were more overconfident of their self-reported driving skills compared to those young drivers with greater access to vehicles. Given that the lifetime mileage positively predicted the simulated violations measure of carless young drivers, immediate interventions are needed to help them increase driving exposure and gain driving experience gradually before moving to more challenging on-road driving tasks. Supplemental materials are available for this article.

  5. Study on mobile phone use while driving in a sample of Iranian drivers.

    PubMed

    Arvin, Ramin; Khademi, Mostafa; Razi-Ardakani, Hesamoddin

    2017-06-01

    The use of cell phone is a significant source of driver distraction. Phone use while driving can impair a number of factors critical for safe driving which can cause serious traffic safety problems. The objective of this paper was to investigate the frequency of using cell phones while driving in Iran's roads through an observational survey with a random sample of drivers, to recognize contributing factors to cell phone usage and to understand the magnitude of the problem. A total of 1794 observations were collected from 12 sites at controlled intersections, entrance and exit points of highways. The cell phone use rate among drivers (talking or texting) was estimated at 10% which is significantly higher than that in other countries such as Australia, USA and Canada. Rate of cell phone use among younger drivers (14.15%) was higher in comparison with other groups. In order to identify factors affecting cell phone use while driving, a binary logit model is estimated. Variables which significantly contribute to the rate of using cell phone were found to be the age of driver, number of passengers, presence of kids under the age of 8, time of observation, vehicle price and type of car.

  6. Medication and Driving-Appropriate Interventions.

    PubMed

    Hitosugi, Masahito

    2017-01-01

    Sudden illness while driving has been identified as a major cause of vehicle collisions, accounting for approximately 1 in 10 collisions. Because most drivers who experience sudden illnesses while driving do not perform avoidance maneuvers, the improvement of drivers' health is being promoted as a traffic safety strategy. Although stroke, heart disease, and epilepsy are common causes of sudden illness, common symptoms, such as abdominal cramps, vertigo, and syncope can also cause problems during driving. We found that regular referral to physicians was significantly less common among drivers who experienced health-related vehicle collisions or incidents. Inadequate control of chronic disease might lead to unusual symptoms and the onset of major attacks. Medications are prescribed to patients to relieve their symptoms and/or bring their diseases under control. However, pharmacists and doctors should ensure that patients are treated with appropriate medications to avoid drivers being distracted due to adverse reactions to medications. The author suggests that it is important to keep drivers in good health and administer appropriate medications if necessary. Both pharmacists and doctors should warn drivers that sudden illness or medication-associated distractions can cause vehicle collisions. Such interventions might contribute to reducing the frequency of sudden illness-related vehicle collisions.

  7. Role of the Ionosphere in the Generation of Large-Amplitude Ulf Waves at High Latitudes

    NASA Astrophysics Data System (ADS)

    Tulegenov, B.; Guido, T.; Streltsov, A. V.

    2014-12-01

    We present results from the statistical study of ULF waves detected by the fluxgate magnetometer in Gakona, Alaska during several experimental campaigns conducted at the High Frequency Active Auroral Research Program (HAARP) facility in years 2011-2013. We analyzed frequencies of ULF waves recorded during 26 strongly disturbed geomagnetic events (substorms) and compared them with frequencies of ULF waves detected during magnetically quite times. Our analysis demonstrates that the frequency of the waves carrying most of the power almost in all these events is less than 1 mHz. We also analyzed data from the ACE satellite, measuring parameters of the solar wind in the L1 Lagrangian point between Earth and Sun, and found that in several occasions there is a strong correlation between oscillations of the magnetic field in the solar wind and oscillations detected on the ground. We also found several cases when there is no correlation between signals detected on ACE and on the ground. This finding suggests that these frequencies correspond to the fundamental eigenfrequency of the coupled magnetosphere-ionosphere system. The low frequency of the oscillations is explained by the effect of the ionosphere, where the current is carried by ions through highly collisional media. The amplitude of these waves can reach significant magnitude when the system is driven by the external driver (for example, the solar wind) with this particular frequency. When the frequency of the driver does not match the frequency of the system, the waves still are observed, but their amplitudes are much smaller.

  8. Carrier envelope offset frequency detection and stabilization of a diode-pumped mode-locked Ti:sapphire laser.

    PubMed

    Gürel, Kutan; Wittwer, Valentin J; Hakobyan, Sargis; Schilt, Stéphane; Südmeyer, Thomas

    2017-03-15

    We demonstrate the first diode-pumped Ti:sapphire laser frequency comb. It is pumped by two green laser diodes with a total pump power of 3 W. The Ti:sapphire laser generates 250 mW of average output power in 61-fs pulses at a repetition rate of 216 MHz. We generated an octave-spanning supercontinuum spectrum in a photonic-crystal fiber and detected the carrier envelope offset (CEO) frequency in a standard f-to-2f interferometer setup. We stabilized the CEO-frequency through direct current modulation of one of the green pump diodes with a feedback bandwidth of 55 kHz limited by the pump diode driver used in this experiment. We achieved a reduction of the CEO phase noise power spectral density by 140 dB at 1 Hz offset frequency. An advantage of diode pumping is the ability for high-bandwidth modulation of the pump power via direct current modulation. After this experiment, we studied the modulation capabilities and noise properties of green pump laser diodes with improved driver electronics. The current-to-output-power modulation transfer function shows a bandwidth larger than 1 MHz, which should be sufficient to fully exploit the modulation bandwidth of the Ti:sapphire gain for CEO stabilization in future experiments.

  9. Psychoactive substance use by truck drivers: a systematic review

    PubMed Central

    Girotto, Edmarlon; Mesas, Arthur Eumann; de Andrade, Selma Maffei; Birolim, Marcela Maria

    2014-01-01

    The aim of this study was to summarise the scientific evidence on the prevalence of psychoactive substance use and on the factors associated with their intake among truck drivers. A systematic review was performed in the databases PubMed, Scientific Electronic Library Online, Latin American and Caribbean Health Sciences, and Cochrane and 36 cross-sectional studies were identified with quantitative results about the use of psychoactive substances by truck drivers. Out of these, 28 were carried out in countries with large land areas and 23 obtained their information through self-reporting. The most frequently studied substances were alcohol (n=25), amphetamines (n=17), marijuana (n=16) and cocaine (n=13). The prevalence of the use of these substances greatly varied: alcohol (0.1–91.0%); amphetamines (0.2–82.5%), marijuana (0.2–29.9%), cocaine (0.1–8.3%). The frequency of substance use was lower in studies that investigated the presence of these substances in biological samples than in those based on self-reported use. In 12 studies that evaluated factors associated with the intake of psychoactive substances, the following stood out: younger age, higher income, longer trips, alcohol consumption, driving in the night shift, travelling interstate routes, long or short sleep, fewer hours of rest, little experience of the driver, connection with small and medium sized companies, income below levels determined by labour agreements, productivity-based earnings and prior involvement in accidents. The frequency of psychoactive substance use by truck drivers seems to be high, although that greatly varies according to the type of substance and the method of collecting the information. The use of these substances was mainly associated with indicators of poor working conditions. PMID:24145953

  10. Psychoactive substance use by truck drivers: a systematic review.

    PubMed

    Girotto, Edmarlon; Mesas, Arthur Eumann; de Andrade, Selma Maffei; Birolim, Marcela Maria

    2014-01-01

    The aim of this study was to summarise the scientific evidence on the prevalence of psychoactive substance use and on the factors associated with their intake among truck drivers. A systematic review was performed in the databases PubMed, Scientific Electronic Library Online, Latin American and Caribbean Health Sciences, and Cochrane and 36 cross-sectional studies were identified with quantitative results about the use of psychoactive substances by truck drivers. Out of these, 28 were carried out in countries with large land areas and 23 obtained their information through self-reporting. The most frequently studied substances were alcohol (n=25), amphetamines (n=17), marijuana (n=16) and cocaine (n=13). The prevalence of the use of these substances greatly varied: alcohol (0.1-91.0%); amphetamines (0.2-82.5%), marijuana (0.2-29.9%), cocaine (0.1-8.3%). The frequency of substance use was lower in studies that investigated the presence of these substances in biological samples than in those based on self-reported use. In 12 studies that evaluated factors associated with the intake of psychoactive substances, the following stood out: younger age, higher income, longer trips, alcohol consumption, driving in the night shift, travelling interstate routes, long or short sleep, fewer hours of rest, little experience of the driver, connection with small and medium sized companies, income below levels determined by labour agreements, productivity-based earnings and prior involvement in accidents. The frequency of psychoactive substance use by truck drivers seems to be high, although that greatly varies according to the type of substance and the method of collecting the information. The use of these substances was mainly associated with indicators of poor working conditions.

  11. High- and Low-Order Overtaking-Ability Affordances: Drivers Rely on the Maximum Velocity and Acceleration of Their Cars to Perform Overtaking Maneuvers.

    PubMed

    Basilio, Numa; Morice, Antoine H P; Marti, Geoffrey; Montagne, Gilles

    2015-08-01

    The aim of this study was to answer the question, Do drivers take into account the action boundaries of their car when overtaking? The Morice et al. affordance-based approach to visually guided overtaking suggests that the "overtake-ability" affordance can be formalized as the ratio of the "minimum satisfying velocity" (MSV) of the maneuver to the maximum velocity (V(max)) of the driven car. In this definition, however, the maximum acceleration (A(max)) of the vehicle is ignored. We hypothesize that drivers may be sensitive to an affordance redefined with the ratio of the "minimum satisfying acceleration" (MSA) to the A(max) of the car. Two groups of nine drivers drove cars differing in their A(max). They were instructed to attempt overtaking maneuvers in 25 situations resulting from the combination of five MSA and five MSV values. When overtaking frequency was expressed as a function of MSV and MSA, maneuvers were found to be initiated differently for the two groups. However, when expressed as a function of MSV/V(max) and MSA/A(max), overtaking frequency was quite similar for both groups. Finally, a multiple regression coefficient analysis demonstrated that overtaking decisions are fully explained by a composite variable comprising MSA/A(max) and the time required to reach MSV. Drivers reliably decide whether overtaking is safe (or not) by using low- and high-order variables taking into account their car's maximum velocity and acceleration, respectively, as predicted by "affordance-based control" theory. Potential applications include the design of overtaking assistance, which should exploit the MSA/A(max) variables in order to suggest perceptually relevant overtaking solutions. © 2015, Human Factors and Ergonomics Society.

  12. The assessment and evaluation of low-frequency noise near the region of infrasound.

    PubMed

    Ziaran, Stanislav

    2014-01-01

    The main aim of this paper is to present recent knowledge about the assessment and evaluation of low-frequency sounds (noise) and infrasound, close to the threshold of hearing, and identify their potential effect on human health and annoyance. Low-frequency noise generated by air flowing over a moving car with an open window was chosen as a typical scenario which can be subjectively assessed by people traveling by automobile. The principle of noise generated within the interior of the car and its effects on the comfort of the driver and passengers are analyzed at different velocities. An open window of a car at high velocity behaves as a source of specifically strong tonal low-frequency noise which is generally perceived as annoying. The interior noise generated by an open window of a passenger car was measured under different conditions: Driving on a highway and driving on a typical roadway. First, an octave-band analysis was used to assess the noise level and its impact on the driver's comfort. Second, a fast Fourier transform (FFT) analysis and one-third octave-band analysis were used for the detection of tonal low-frequency noise. Comparison between two different car makers was also done. Finally, the paper suggests some possibilities for scientifically assessing and evaluating low-frequency sounds in general, and some recommendations are introduced for scientific discussion, since sounds with strong low-frequency content (but not only strong) engender greater annoyance than is predicted by an A-weighted sound pressure level.

  13. Pixel parallel localized driver design for a 128 x 256 pixel array 3D 1Gfps image sensor

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Dao, V. T. S.; Etoh, T. G.; Charbon, E.

    2017-02-01

    In this paper, a 3D 1Gfps BSI image sensor is proposed, where 128 × 256 pixels are located in the top-tier chip and a 32 × 32 localized driver array in the bottom-tier chip. Pixels are designed with Multiple Collection Gates (MCG), which collects photons selectively with different collection gates being active at intervals of 1ns to achieve 1Gfps. For the drivers, a global PLL is designed, which consists of a ring oscillator with 6-stage current starved differential inverters, achieving a wide frequency tuning range from 40MHz to 360MHz (20ps rms jitter). The drivers are the replicas of the ring oscillator that operates within a PLL. Together with level shifters and XNOR gates, continuous 3.3V pulses are generated with desired pulse width, which is 1/12 of the PLL clock period. The driver array is activated by a START signal, which propagates through a highly balanced clock tree, to activate all the pixels at the same time with virtually negligible skew.

  14. A high-efficiency acoustic chamber and the anomalous sample rotation

    NASA Technical Reports Server (NTRS)

    Wang, Taylor G.; Allen, J. L.

    1992-01-01

    A high efficiency acoustic chamber for the levitation and manipulation of liquid or molten samples in a microgravity environment has been developed. The chamber uses two acoustic drivers that are mounted at opposite corners of the chamber; by driving these at the same frequency, with 18-deg phase shifts, an increase in force of a factor of 3-4 is obtainable relative to the force of a single-driver system that is operated at the same power level. This enhancement is due to the increased coupling between the sound driver and the chamber. An anomalous rotation is noted to be associated with the chamber; this is found to be eliminated by a physically as-yet inexplicable empirical solution.

  15. Preliminary design considerations for 10 to 40 meter-diameter precision truss reflectors

    NASA Technical Reports Server (NTRS)

    Mikulas, Martin M., Jr.; Collins, Timothy J.; Hedgepeth, John M.

    1990-01-01

    A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.

  16. Clonal status of actionable driver events and the timing of mutational processes in cancer evolution

    PubMed Central

    McGranahan, Nicholas; Favero, Francesco; de Bruin, Elza C.; Birkbak, Nicolai Juul; Szallasi, Zoltan; Swanton, Charles

    2015-01-01

    Deciphering whether actionable driver mutations are found in all or a subset of tumor cells will likely be required to improve drug development and precision medicine strategies. We analyzed nine cancer types to determine the subclonal frequencies of driver events, to time mutational processes during cancer evolution, and to identify drivers of subclonal expansions. Although mutations in known driver genes typically occurred early in cancer evolution, we also identified later subclonal “actionable” mutations, including BRAF(V600E), IDH1(R132H), PIK3CA(E545K), EGFR(L858R), and KRAS(G12D), which may compromise the efficacy of targeted therapy approaches. More than 20% of IDH1 mutations in glioblastomas, and 15% of mutations in genes in the PI3K(phosphatidylinositol 3-kinase)–AKT–mTOR (mammalian target of rapamycin) signaling axis across all tumor types were subclonal. Mutations in the RAS–MEK (mitogen-activated protein kinase kinase) signaling axis were less likely to be subclonal than mutations in genes associated with PI3K-AKT-mTORsignaling. Analysis of late mutations revealed a link between APOBEC-mediated mutagenesis and the acquisition of subclonal driver mutations and uncovered putative cancer genes involved in subclonal expansions, including CTNNA2 and ATXN1. Our results provide a pan-cancer census of driver events within the context of intratumor heterogeneity and reveal patterns of tumor evolution across cancers. The frequent presence of subclonal driver mutations suggests the need to stratify targeted therapy response according to the proportion of tumor cells in which the driver is identified. PMID:25877892

  17. Drinking characteristics of drivers arrested for driving while intoxicated in two police jurisdictions.

    PubMed

    Fell, James C; Tippetts, Scott; Voas, Robert

    2010-10-01

    Are drivers arrested for driving while intoxicated (DWI) most likely to be the drinking drivers who are involved in fatal and serious injury crashes? This study determined the drinking characteristics of drivers arrested for DWI or driving under the influence (DUI) and the proportion classified as problem drinkers and hardcore drinking drivers in two police jurisdictions. In addition to determining the drinking characteristics of DWI arrestees, the results were compared to the drinking characteristics of intoxicated drivers killed in traffic crashes. Police officers gathered data at the time of arrest from 1027 drivers apprehended for DWI or DUI in the two communities on their alcohol consumption, their drinking-and-driving frequency, their self-reported alcohol problems, their place of drinking and types of drinks before the arrest, and their perceptions of impaired-driving enforcement intensity. Data analyses indicated that 52 percent of the arrested DWI offenders were considered problem drinkers, 46 percent were repeat offenders, 57 percent were classified as hardcore drinking drivers, 51 percent were drinking at a bar or restaurant before their arrest, and 72 percent were drinking beer before their arrest. Compared to highly intoxicated (blood alcohol concentration [BAC] ≥.15) drivers killed in traffic crashes, the high-BAC arrestees were substantially more likely to be problem drinkers and to report drinking and driving more often. The limited resources available for combating impaired driving should not be solely allocated to problem drinkers, hardcore drinkers, or repeat offenders because, at most, they constitute only about half of the impaired-driving problem in the United States. General deterrent strategies have the best chance of impacting the total population of at-risk drinking drivers.

  18. Can variations in visual behavior measures be good predictors of driver sleepiness? A real driving test study.

    PubMed

    Wang, Yonggang; Xin, Mengyang; Bai, Han; Zhao, Yangdong

    2017-02-17

    The primary purpose of this study was to examine the association between variations in visual behavior measures and subjective sleepiness levels across age groups over time to determine a quantitative method of measuring drivers' sleepiness levels. A total of 128 volunteer drivers in 4 age groups were asked to finish 2-, 3-, and 4-h continuous driving tasks on expressways, during which the driver's fixation, saccade, and blink measures were recorded by an eye-tracking system and the subjective sleepiness level was measured through the Stanford Sleepiness Scale. Two-way repeated measures analysis of variance was then used to examine the change in visual behavior measures across age groups over time and compare the interactive effects of these 2 factors on the dependent visual measures. Drivers' visual behavior measures and subjective sleepiness levels vary significantly over time but not across age groups. A statistically significant interaction between age group and driving duration was found in drivers' pupil diameter, deviation of search angle, saccade amplitude, blink frequency, blink duration, and closure duration. Additionally, change in a driver's subjective sleepiness level is positively or negatively associated with variation in visual behavior measures, and such relationships can be expressed in regression models for different period of driving duration. Driving duration affects drivers' sleepiness significantly, so the amount of continuous driving time should be strictly controlled. Moreover, driving sleepiness can be quantified through the change rate of drivers' visual behavior measures to alert drivers of sleepiness risk and to encourage rest periods. These results provide insight into potential strategies for reducing and preventing traffic accidents and injuries.

  19. Potential distractions and unsafe driving behaviors among drivers of 1- to 12-year-old children.

    PubMed

    Macy, Michelle L; Carter, Patrick M; Bingham, C Raymond; Cunningham, Rebecca M; Freed, Gary L

    2014-01-01

    Driver distraction has been identified as a threat to individual drivers and public health. Motor vehicle collisions remain a leading cause of death for children, yet little is known about distractions among drivers of children. This study sought to characterize potential distractions among drivers of children. A 2-site, cross-sectional, computerized survey of child passenger safety practices was conducted among adult drivers of 1- to 12-year-old children who presented for emergency care between October 2011 to May 2012. Drivers indicated the frequency with which they engaged in 10 potential distractions in the past month while driving with their child. Distractions were grouped in 4 categories: (1) nondriving, (2) cellular phone, (3) child, and (4) directions. Information about other unsafe driving behaviors and sociodemographic characteristics was collected. Nearly 90% of eligible parents participated. Analysis included 570 drivers (92.2%). Non-driving-related and cellular phone-related distractions were disclosed by >75% of participants. Fewer participants disclosed child (71.2%) and directions-related distractions (51.9%). Child age was associated with each distraction category. Cellular phone-related distractions were associated with the child riding daily in the family car, non-Hispanic white, and higher education. Parents admitting to drowsy driving and being pulled over for speeding had over 2 times higher odds of disclosing distractions from each category. Distracted driving activities are common among drivers of child passengers and are associated with other unsafe driving behaviors. Child passenger safety may be improved by preventing crash events through the reduction or elimination of distractions among drivers of child passengers. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  20. Potential Distractions and Unsafe Driving Behaviors Among Drivers of 1- to 12-year-old Children

    PubMed Central

    Macy, Michelle L.; Carter, Patrick M.; Bingham, C. Raymond; Cunningham, Rebecca M.; Freed, Gary L.

    2014-01-01

    Objective Driver distraction has been identified as a threat to individual drivers and public health. Motor vehicle collisions remain a leading cause of death for children yet little is known about distractions among drivers of children. This study sought to characterize potential distractions among drivers of children. Methods A two-site, cross-sectional, computerized survey of child passenger safety practices was conducted among adult drivers of 1- to 12-year-old children who presented for emergency care between October 2011-May 2012. Drivers indicated the frequency with which they engaged in ten potential distractions in the past month while driving with their child. Distractions were grouped in four categories: 1) non-driving, 2) cellular phone, 3) child, 4) directions. Information about other unsafe driving behaviors and sociodemographic characteristics was collected. Results Nearly 90% of eligible parents participated. Analysis included 570 (92.2%) drivers. Non-driving and cellular phone-related distractions were disclosed by >75% of participants. Fewer participants disclosed child (71.2%) and directions-related distractions (51.9%). Child age was associated with each distraction category. Cellular phone-related distractions were associated with the child riding daily in the family car, non-Hispanic white and other race/ethnicity, and higher education. Parents admitting to drowsy driving and being pulled over for speeding had over two-times higher odds of disclosing distractions from each category. Conclusions Distracted driving activities are common among drivers of child passengers and associated with other unsafe driving behaviors. Child passenger safety may be improved by preventing crash events through the reduction or elimination of distractions among drivers of child passengers. PMID:24767781

  1. New Image-Based Techniques for Prostate Biopsy and Treatment

    DTIC Science & Technology

    2012-04-01

    C-arm fluoroscopy, MICCAI 2011, Toronto, Canada, 2011. 4) Poster Presentation: Prostate Cancer Probability Estimation Based on DCE- DTI Features...and P. Kozlowski, “Prostate Cancer Probability Estimation Based on DCE- DTI Features and Support Vector Machine Classification,” Annual Meeting of... DTI ), which characterize the de-phasing of the MR signal caused by molecular diffusion. Prostate cancer causes a pathological change in the tissue

  2. Architecture of a high-performance surgical guidance system based on C-arm cone-beam CT: software platform for technical integration and clinical translation

    NASA Astrophysics Data System (ADS)

    Uneri, Ali; Schafer, Sebastian; Mirota, Daniel; Nithiananthan, Sajendra; Otake, Yoshito; Reaungamornrat, Sureerat; Yoo, Jongheun; Stayman, J. Webster; Reh, Douglas; Gallia, Gary L.; Khanna, A. Jay; Hager, Gregory; Taylor, Russell H.; Kleinszig, Gerhard; Siewerdsen, Jeffrey H.

    2011-03-01

    Intraoperative imaging modalities are becoming more prevalent in recent years, and the need for integration of these modalities with surgical guidance is rising, creating new possibilities as well as challenges. In the context of such emerging technologies and new clinical applications, a software architecture for cone-beam CT (CBCT) guided surgery has been developed with emphasis on binding open-source surgical navigation libraries and integrating intraoperative CBCT with novel, application-specific registration and guidance technologies. The architecture design is focused on accelerating translation of task-specific technical development in a wide range of applications, including orthopaedic, head-and-neck, and thoracic surgeries. The surgical guidance system is interfaced with a prototype mobile C-arm for high-quality CBCT and through a modular software architecture, integration of different tools and devices consistent with surgical workflow in each of these applications is realized. Specific modules are developed according to the surgical task, such as: 3D-3D rigid or deformable registration of preoperative images, surgical planning data, and up-to-date CBCT images; 3D-2D registration of planning and image data in real-time fluoroscopy and/or digitally reconstructed radiographs (DRRs); compatibility with infrared, electromagnetic, and video-based trackers used individually or in hybrid arrangements; augmented overlay of image and planning data in endoscopic or in-room video; real-time "virtual fluoroscopy" computed from GPU-accelerated DRRs; and multi-modality image display. The platform aims to minimize offline data processing by exposing quantitative tools that analyze and communicate factors of geometric precision. The system was translated to preclinical phantom and cadaver studies for assessment of fiducial (FRE) and target registration error (TRE) showing sub-mm accuracy in targeting and video overlay within intraoperative CBCT. The work culminates in the development of a CBCT guidance system (reported here for the first time) that leverages the technical developments in Carm CBCT and associated technologies for realizing a high-performance system for translation to clinical studies.

  3. WE-AB-BRA-08: Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouadah, S; Jacobson, M; Stayman, JW

    2016-06-15

    Purpose: Intraoperative C-arm cone-beam CT (CBCT) is subject to artifacts arising from patient motion during the fairly long (∼5–20 s) scan times. We present a fiducial free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in geometric calibration. Methods: A 3D-2D registration process was used to register each projection to DRRs computed from the 3D image by maximizing gradient orientation (GO) using the CMA-ES optimizer. The resulting rigid 6 DOF transforms were applied to the system projection matrices, and a 3D image was reconstructed via model-based image reconstruction (MBIR, which accommodates the resulting noncircularmore » orbit). Experiments were conducted using a Zeego robotic C-arm (20 s, 200°, 496 projections) to image a head phantom undergoing various types of motion: 1) 5° lateral motion; 2) 15° lateral motion; and 3) 5° lateral motion with 10 mm periodic inferior-superior motion. Images were reconstructed using a penalized likelihood (PL) objective function, and structural similarity (SSIM) was measured for axial slices of the reconstructed images. A motion-free image was acquired using the same protocol for comparison. Results: There was significant improvement (p < 0.001) in the SSIM of the motion-corrected (MC) images compared to uncorrected images. The SSIM in MC-PL images was >0.99, indicating near identity to the motion-free reference. The point spread function (PSF) measured from a wire in the phantom was restored to that of the reference in each case. Conclusion: The 3D-2D registration method provides a robust framework for mitigation of motion artifacts and is expected to hold for applications in the head, pelvis, and extremities with reasonably constrained operative setup. Further improvement can be achieved by incorporating multiple rigid components and non-rigid deformation within the framework. The method is highly parallelizable and could in principle be run with every acquisition. Research supported by National Institutes of Health Grant No. R01-EB-017226 and academic-industry partnership with Siemens Healthcare (AX Division, Forcheim, Germany).« less

  4. Whole brain C-arm computed tomography parenchymal blood volume measurements

    PubMed Central

    Byrne, James V

    2016-01-01

    Introduction C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) imaging in the neuro-interventional suite is a new technique for which detailed whole brain measurements have not been previously reported. This study aims to create a catalogue of PBV measurements for various anatomical regions encompassing the whole brain, using a three-dimensional volume-of-interest (3D-VOI) analysis. Methods We acquired and analysed 30 C-arm FDCT datasets from 26 patients with aneurysmal subarachnoid haemorrhage (SAH), as part of a prospective study comparing C-arm computed tomography (CT) PBV with magnetic resonance perfusion-weighted imaging (MR-PWI). We calculated the PBV values for various brain regions with an automated analysis, using 58 pre-defined atlas-based 3D-VOIs encompassing the whole brain. VOIs partially or completely overlapping regions of magnetic resonance diffusion weighted imaging (MR-DWI) abnormality or magnetic resonance cerebral blood flow (MR-CBF) asymmetry were excluded from the analysis. Results Of the 30 C-arm CT PBV datasets, 14 (54%; 12 patients) had areas of restricted diffusion, the majority of which were focal. The PBV values for the cerebral cortex and cerebral white matter were 4.01 ± 0.47 (mean ± SD) and 3.01 ± 0.39 ml per 100 ml. Lobar PBV values were: frontal lobe 4.2 ± 0.8, temporal lobe 4.2 ± 0.9, parietal lobe 3.9 ± 0.7 and occipital lobe 4.3 ± 0.8 ml/100 ml. The basal ganglia and brainstem PBV values were 3.4 ± 0.7 and 4.6 ± 0.6 ml/100 ml, respectively. Conclusions Compared with the typical reference cerebral blood volume (CBV) values reported in the literature for Positron Emission Tomography (PET), the PBV values were relatively high for the white matter and relatively low for the cortical grey matter. The reported catalogue of PBV values for various brain regions would be useful to inform future studies and could be used in clinical practice, when interpreting PBV maps. PMID:26769737

  5. Whole brain C-arm computed tomography parenchymal blood volume measurements.

    PubMed

    Kamran, Mudassar; Byrne, James V

    2016-04-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) imaging in the neuro-interventional suite is a new technique for which detailed whole brain measurements have not been previously reported. This study aims to create a catalogue of PBV measurements for various anatomical regions encompassing the whole brain, using a three-dimensional volume-of-interest (3D-VOI) analysis. We acquired and analysed 30 C-arm FDCT datasets from 26 patients with aneurysmal subarachnoid haemorrhage (SAH), as part of a prospective study comparing C-arm computed tomography (CT) PBV with magnetic resonance perfusion-weighted imaging (MR-PWI). We calculated the PBV values for various brain regions with an automated analysis, using 58 pre-defined atlas-based 3D-VOIs encompassing the whole brain. VOIs partially or completely overlapping regions of magnetic resonance diffusion weighted imaging (MR-DWI) abnormality or magnetic resonance cerebral blood flow (MR-CBF) asymmetry were excluded from the analysis. Of the 30 C-arm CT PBV datasets, 14 (54%; 12 patients) had areas of restricted diffusion, the majority of which were focal. The PBV values for the cerebral cortex and cerebral white matter were 4.01 ± 0.47 (mean ± SD) and 3.01 ± 0.39 ml per 100 ml. Lobar PBV values were: frontal lobe 4.2 ± 0.8, temporal lobe 4.2 ± 0.9, parietal lobe 3.9 ± 0.7 and occipital lobe 4.3 ± 0.8 ml/100 ml. The basal ganglia and brainstem PBV values were 3.4 ± 0.7 and 4.6 ± 0.6 ml/100 ml, respectively. Compared with the typical reference cerebral blood volume (CBV) values reported in the literature for Positron Emission Tomography (PET), the PBV values were relatively high for the white matter and relatively low for the cortical grey matter. The reported catalogue of PBV values for various brain regions would be useful to inform future studies and could be used in clinical practice, when interpreting PBV maps. © The Author(s) 2016.

  6. WE-G-18A-01: JUNIOR INVESTIGATOR WINNER - Low-Dose C-Arm Cone-Beam CT with Model-Based Image Reconstruction for High-Quality Guidance of Neurosurgical Intervention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, A; Stayman, J; Otake, Y

    Purpose: To address the challenges of image quality, radiation dose, and reconstruction speed in intraoperative cone-beam CT (CBCT) for neurosurgery by combining model-based image reconstruction (MBIR) with accelerated algorithmic and computational methods. Methods: Preclinical studies involved a mobile C-arm for CBCT imaging of two anthropomorphic head phantoms that included simulated imaging targets (ventricles, soft-tissue structures/bleeds) and neurosurgical procedures (deep brain stimulation (DBS) electrode insertion) for assessment of image quality. The penalized likelihood (PL) framework was used for MBIR, incorporating a statistical model with image regularization via an edgepreserving penalty. To accelerate PL reconstruction, the ordered-subset, separable quadratic surrogates (OS-SQS) algorithmmore » was modified to incorporate Nesterov's method and implemented on a multi-GPU system. A fair comparison of image quality between PL and conventional filtered backprojection (FBP) was performed by selecting reconstruction parameters that provided matched low-contrast spatial resolution. Results: CBCT images of the head phantoms demonstrated that PL reconstruction improved image quality (∼28% higher CNR) even at half the radiation dose (3.3 mGy) compared to FBP. A combination of Nesterov's method and fast projectors yielded a PL reconstruction run-time of 251 sec (cf., 5729 sec for OS-SQS, 13 sec for FBP). Insertion of a DBS electrode resulted in severe metal artifact streaks in FBP reconstructions, whereas PL was intrinsically robust against metal artifact. The combination of noise and artifact was reduced from 32.2 HU in FBP to 9.5 HU in PL, thereby providing better assessment of device placement and potential complications. Conclusion: The methods can be applied to intraoperative CBCT for guidance and verification of neurosurgical procedures (DBS electrode insertion, biopsy, tumor resection) and detection of complications (intracranial hemorrhage). Significant improvement in image quality, dose reduction, and reconstruction time of ∼4 min will enable practical deployment of low-dose C-arm CBCT within the operating room. AAPM Research Seed Funding (2013-2014); NIH Fellowship F32EB017571; Siemens Healthcare (XP Division)« less

  7. Critical older driver errors in a national sample of serious U.S. crashes.

    PubMed

    Cicchino, Jessica B; McCartt, Anne T

    2015-07-01

    Older drivers are at increased risk of crash involvement per mile traveled. The purpose of this study was to examine older driver errors in serious crashes to determine which errors are most prevalent. The National Highway Traffic Safety Administration's National Motor Vehicle Crash Causation Survey collected in-depth, on-scene data for a nationally representative sample of 5470 U.S. police-reported passenger vehicle crashes during 2005-2007 for which emergency medical services were dispatched. There were 620 crashes involving 647 drivers aged 70 and older, representing 250,504 crash-involved older drivers. The proportion of various critical errors made by drivers aged 70 and older were compared with those made by drivers aged 35-54. Driver error was the critical reason for 97% of crashes involving older drivers. Among older drivers who made critical errors, the most common were inadequate surveillance (33%) and misjudgment of the length of a gap between vehicles or of another vehicle's speed, illegal maneuvers, medical events, and daydreaming (6% each). Inadequate surveillance (33% vs. 22%) and gap or speed misjudgment errors (6% vs. 3%) were more prevalent among older drivers than middle-aged drivers. Seventy-one percent of older drivers' inadequate surveillance errors were due to looking and not seeing another vehicle or failing to see a traffic control rather than failing to look, compared with 40% of inadequate surveillance errors among middle-aged drivers. About two-thirds (66%) of older drivers' inadequate surveillance errors and 77% of their gap or speed misjudgment errors were made when turning left at intersections. When older drivers traveled off the edge of the road or traveled over the lane line, this was most commonly due to non-performance errors such as medical events (51% and 44%, respectively), whereas middle-aged drivers were involved in these crash types for other reasons. Gap or speed misjudgment errors and inadequate surveillance errors were significantly more prevalent among female older drivers than among female middle-aged drivers, but the prevalence of these errors did not differ significantly between older and middle-aged male drivers. These errors comprised 51% of errors among older female drivers but only 31% among older male drivers. Efforts to reduce older driver crash involvements should focus on diminishing the likelihood of the most common driver errors. Countermeasures that simplify or remove the need to make left turns across traffic such as roundabouts, protected left turn signals, and diverging diamond intersection designs could decrease the frequency of inadequate surveillance and gap or speed misjudgment errors. In the future, vehicle-to-vehicle and vehicle-to-infrastructure communications may also help protect older drivers from these errors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. The Global Drivers of Photosynthesis and Light Use Efficiency Seasonality: A Granger Frequency Causality Analysis

    NASA Astrophysics Data System (ADS)

    Green, J.; Lee, J. E.; Gentine, P.; Berry, J. A.; Konings, A. G.

    2015-12-01

    hotosynthesis and light use efficiency (LUE) are major factors in the evolution of the continental carbon cycle due to their contribution to gross primary production (GPP). However, while the drivers of photosynthesis and LUE on a plant or canopy scale can often be identified, significant uncertainties exist when modeling these on a global scale. This is due to sparse observations in regions such as the tropics and the lack of a direct global observation dataset. Although others have attempted to address this issue using correlations (Beer, 2010) or calculating GPP from vegetation indices (Running, 2004), in this study we take a new approach. We combine the statistical method of Granger frequency causality and partial Granger frequency causality with remote sensing data products (including sun-induced fluorescence used as a proxy for GPP) to determine the main environmental drivers of GPP across the globe. References:Beer, C., M. Reichstein, E. Tomelleri, P. Ciais, M. Jung, N. Carvalhais, C. Ro¨denbeck, M. Altaf Arain, D. Baldocchi, G. B. Bonan, A. Bondeau, A. Cescatti, G. Lasslop, A. Lindroth, M. Lomas, S. Luyssaert, H. Margolis, K. W. Oleson, O. Roupsard, E. Veenendaal, N. Viovy, C. Williams, I. Woodward, and D. Papale, 2010: Terrestrial Gross Carbon Dioxide Uptake: Global Distribution and Covariation with Climate. doi: 10.1126/science.1184984. Running, S.W., Nemani, R. R., Heinsch, F. A., Zhao, M., Reeves, M., Hashimoto, H., 2004. A Continuous Satellite Derived Measure of Global Terrestrial Primary Production. BioScience 54(6), 547-560.

  9. MADGiC: a model-based approach for identifying driver genes in cancer

    PubMed Central

    Korthauer, Keegan D.; Kendziorski, Christina

    2015-01-01

    Motivation: Identifying and prioritizing somatic mutations is an important and challenging area of cancer research that can provide new insights into gene function as well as new targets for drug development. Most methods for prioritizing mutations rely primarily on frequency-based criteria, where a gene is identified as having a driver mutation if it is altered in significantly more samples than expected according to a background model. Although useful, frequency-based methods are limited in that all mutations are treated equally. It is well known, however, that some mutations have no functional consequence, while others may have a major deleterious impact. The spatial pattern of mutations within a gene provides further insight into their functional consequence. Properly accounting for these factors improves both the power and accuracy of inference. Also important is an accurate background model. Results: Here, we develop a Model-based Approach for identifying Driver Genes in Cancer (termed MADGiC) that incorporates both frequency and functional impact criteria and accommodates a number of factors to improve the background model. Simulation studies demonstrate advantages of the approach, including a substantial increase in power over competing methods. Further advantages are illustrated in an analysis of ovarian and lung cancer data from The Cancer Genome Atlas (TCGA) project. Availability and implementation: R code to implement this method is available at http://www.biostat.wisc.edu/ kendzior/MADGiC/. Contact: kendzior@biostat.wisc.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25573922

  10. Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with Magnetic Resonance Elastography (MRE)

    PubMed Central

    Leclerc, Gwladys E.; Debernard, Laetitia; Foucart, Félix; Robert, Ludovic; Pelletier, Kay M.; Charleux, Fabrice; Ehman, Richard; Tho, Marie-Christine Ho Ba; Bensamoun, Sabine F.

    2012-01-01

    The purpose of this study was to create a polymer phantom mimicking the mechanical properties of soft tissues using experimental tests and rheological models. Multifrequency Magnetic Resonance Elastography (MMRE) tests were performed on the present phantom with a pneumatic driver to characterize the viscoelastic (μ, η) properties using Voigt, Maxwell, Zener and Springpot models. To optimize the MMRE protocol, the driver behavior was analyzed with a vibrometer. Moreover, the hyperelastic properties of the phantom were determined using compressive tests and Mooney-Rivlin model. The range of frequency to be used with the round driver was found between 60 Hz and 100 Hz as it exhibits one type of vibration mode for the membrane. MRE analysis revealed an increase in the shear modulus with frequency reflecting the viscoelastic properties of the phantom showing similar characteristic of soft tissues. Rheological results demonstrated that Springpot model better revealed the viscoelastic properties (μ = 3.45 kPa, η = 6.17 Pa.s) of the phantom and the Mooney-Rivlin coefficients were C10 = 1.09.10-2 MPa and C01 = −8.96.10-3 MPa corresponding to μ = 3.95 kPa. These studies suggest that the phantom, mimicking soft tissue, could be used for preliminary MRE tests to identify the optimal parameters necessary for in vivo investigations. Further developments of the phantom may allow clinicians to more accurately mimic healthy and pathological soft tissues using MRE. PMID:22284992

  11. Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with magnetic resonance elastography (MRE).

    PubMed

    Leclerc, Gwladys E; Debernard, Laëtitia; Foucart, Félix; Robert, Ludovic; Pelletier, Kay M; Charleux, Fabrice; Ehman, Richard; Ho Ba Tho, Marie-Christine; Bensamoun, Sabine F

    2012-04-05

    The purpose of this study was to create a polymer phantom mimicking the mechanical properties of soft tissues using experimental tests and rheological models. Multifrequency Magnetic Resonance Elastography (MMRE) tests were performed on the present phantom with a pneumatic driver to characterize the viscoelastic (μ, η) properties using Voigt, Maxwell, Zener and Springpot models. To optimize the MMRE protocol, the driver behavior was analyzed with a vibrometer. Moreover, the hyperelastic properties of the phantom were determined using compressive tests and Mooney-Rivlin model. The range of frequency to be used with the round driver was found between 60 Hz and 100 Hz as it exhibits one type of vibration mode for the membrane. MRE analysis revealed an increase in the shear modulus with frequency reflecting the viscoelastic properties of the phantom showing similar characteristic of soft tissues. Rheological results demonstrated that Springpot model better revealed the viscoelastic properties (μ=3.45 kPa, η=6.17 Pas) of the phantom and the Mooney-Rivlin coefficients were C(10)=1.09.10(-2) MPa and C(01)=-8.96.10(-3) MPa corresponding to μ=3.95 kPa. These studies suggest that the phantom, mimicking soft tissue, could be used for preliminary MRE tests to identify the optimal parameters necessary for in vivo investigations. Further developments of the phantom may allow clinicians to more accurately mimic healthy and pathological soft tissues using MRE. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. VarWalker: Personalized Mutation Network Analysis of Putative Cancer Genes from Next-Generation Sequencing Data

    PubMed Central

    Jia, Peilin; Zhao, Zhongming

    2014-01-01

    A major challenge in interpreting the large volume of mutation data identified by next-generation sequencing (NGS) is to distinguish driver mutations from neutral passenger mutations to facilitate the identification of targetable genes and new drugs. Current approaches are primarily based on mutation frequencies of single-genes, which lack the power to detect infrequently mutated driver genes and ignore functional interconnection and regulation among cancer genes. We propose a novel mutation network method, VarWalker, to prioritize driver genes in large scale cancer mutation data. VarWalker fits generalized additive models for each sample based on sample-specific mutation profiles and builds on the joint frequency of both mutation genes and their close interactors. These interactors are selected and optimized using the Random Walk with Restart algorithm in a protein-protein interaction network. We applied the method in >300 tumor genomes in two large-scale NGS benchmark datasets: 183 lung adenocarcinoma samples and 121 melanoma samples. In each cancer, we derived a consensus mutation subnetwork containing significantly enriched consensus cancer genes and cancer-related functional pathways. These cancer-specific mutation networks were then validated using independent datasets for each cancer. Importantly, VarWalker prioritizes well-known, infrequently mutated genes, which are shown to interact with highly recurrently mutated genes yet have been ignored by conventional single-gene-based approaches. Utilizing VarWalker, we demonstrated that network-assisted approaches can be effectively adapted to facilitate the detection of cancer driver genes in NGS data. PMID:24516372

  13. VarWalker: personalized mutation network analysis of putative cancer genes from next-generation sequencing data.

    PubMed

    Jia, Peilin; Zhao, Zhongming

    2014-02-01

    A major challenge in interpreting the large volume of mutation data identified by next-generation sequencing (NGS) is to distinguish driver mutations from neutral passenger mutations to facilitate the identification of targetable genes and new drugs. Current approaches are primarily based on mutation frequencies of single-genes, which lack the power to detect infrequently mutated driver genes and ignore functional interconnection and regulation among cancer genes. We propose a novel mutation network method, VarWalker, to prioritize driver genes in large scale cancer mutation data. VarWalker fits generalized additive models for each sample based on sample-specific mutation profiles and builds on the joint frequency of both mutation genes and their close interactors. These interactors are selected and optimized using the Random Walk with Restart algorithm in a protein-protein interaction network. We applied the method in >300 tumor genomes in two large-scale NGS benchmark datasets: 183 lung adenocarcinoma samples and 121 melanoma samples. In each cancer, we derived a consensus mutation subnetwork containing significantly enriched consensus cancer genes and cancer-related functional pathways. These cancer-specific mutation networks were then validated using independent datasets for each cancer. Importantly, VarWalker prioritizes well-known, infrequently mutated genes, which are shown to interact with highly recurrently mutated genes yet have been ignored by conventional single-gene-based approaches. Utilizing VarWalker, we demonstrated that network-assisted approaches can be effectively adapted to facilitate the detection of cancer driver genes in NGS data.

  14. A Hybrid Approach to Detect Driver Drowsiness Utilizing Physiological Signals to Improve System Performance and Wearability.

    PubMed

    Awais, Muhammad; Badruddin, Nasreen; Drieberg, Micheal

    2017-08-31

    Driver drowsiness is a major cause of fatal accidents, injury, and property damage, and has become an area of substantial research attention in recent years. The present study proposes a method to detect drowsiness in drivers which integrates features of electrocardiography (ECG) and electroencephalography (EEG) to improve detection performance. The study measures differences between the alert and drowsy states from physiological data collected from 22 healthy subjects in a driving simulator-based study. A monotonous driving environment is used to induce drowsiness in the participants. Various time and frequency domain feature were extracted from EEG including time domain statistical descriptors, complexity measures and power spectral measures. Features extracted from the ECG signal included heart rate (HR) and heart rate variability (HRV), including low frequency (LF), high frequency (HF) and LF/HF ratio. Furthermore, subjective sleepiness scale is also assessed to study its relationship with drowsiness. We used paired t -tests to select only statistically significant features ( p < 0.05), that can differentiate between the alert and drowsy states effectively. Significant features of both modalities (EEG and ECG) are then combined to investigate the improvement in performance using support vector machine (SVM) classifier. The other main contribution of this paper is the study on channel reduction and its impact to the performance of detection. The proposed method demonstrated that combining EEG and ECG has improved the system's performance in discriminating between alert and drowsy states, instead of using them alone. Our channel reduction analysis revealed that an acceptable level of accuracy (80%) could be achieved by combining just two electrodes (one EEG and one ECG), indicating the feasibility of a system with improved wearability compared with existing systems involving many electrodes. Overall, our results demonstrate that the proposed method can be a viable solution for a practical driver drowsiness system that is both accurate and comfortable to wear.

  15. A Hybrid Approach to Detect Driver Drowsiness Utilizing Physiological Signals to Improve System Performance and Wearability

    PubMed Central

    Badruddin, Nasreen

    2017-01-01

    Driver drowsiness is a major cause of fatal accidents, injury, and property damage, and has become an area of substantial research attention in recent years. The present study proposes a method to detect drowsiness in drivers which integrates features of electrocardiography (ECG) and electroencephalography (EEG) to improve detection performance. The study measures differences between the alert and drowsy states from physiological data collected from 22 healthy subjects in a driving simulator-based study. A monotonous driving environment is used to induce drowsiness in the participants. Various time and frequency domain feature were extracted from EEG including time domain statistical descriptors, complexity measures and power spectral measures. Features extracted from the ECG signal included heart rate (HR) and heart rate variability (HRV), including low frequency (LF), high frequency (HF) and LF/HF ratio. Furthermore, subjective sleepiness scale is also assessed to study its relationship with drowsiness. We used paired t-tests to select only statistically significant features (p < 0.05), that can differentiate between the alert and drowsy states effectively. Significant features of both modalities (EEG and ECG) are then combined to investigate the improvement in performance using support vector machine (SVM) classifier. The other main contribution of this paper is the study on channel reduction and its impact to the performance of detection. The proposed method demonstrated that combining EEG and ECG has improved the system’s performance in discriminating between alert and drowsy states, instead of using them alone. Our channel reduction analysis revealed that an acceptable level of accuracy (80%) could be achieved by combining just two electrodes (one EEG and one ECG), indicating the feasibility of a system with improved wearability compared with existing systems involving many electrodes. Overall, our results demonstrate that the proposed method can be a viable solution for a practical driver drowsiness system that is both accurate and comfortable to wear. PMID:28858220

  16. Whole body vibration and posture as risk factors for low back pain among forklift truck drivers

    NASA Astrophysics Data System (ADS)

    Hoy, J.; Mubarak, N.; Nelson, S.; Sweerts de Landas, M.; Magnusson, M.; Okunribido, O.; Pope, M.

    2005-06-01

    A cross-sectional study was conducted to investigate the risks from whole-body vibration and posture demands for low back pain (LBP) among forklift truck (forklift) drivers. Using a validated questionnaire, information about health history was obtained over a period of two weeks in face-to-face interviews. The forklift drivers were observed in respect of their sitting posture, including frequency with which different positions were adopted (bending, leaning and twisting) and postural analyses were conducted using the OWAS and RULA techniques. Forklift vibrations at the seat (exposure) were measured in the three orthogonal axes ( x-fore and aft, y-lateral and z-vertical) under actual working conditions according to the recommendations of ISO 2631-1. The results showed that LBP was more prevalent amongst forklift drivers than among non-drivers and driving postures in which the trunk is considerably twisted or bent forward associated with greatest risk. Furthermore, forklift drivers showed to be exposed to acceptable levels of vibration in the x- and y-directions (i.e., below the EU Physical Agents Directive on Vibration Exposure recommended action level—0.5 m/s 2), but not in the z-direction. There were indications that whole-body vibration acts associatively with other factors (not independently) to precipitate LBP.

  17. Assessing combined exposures of whole-body vibration and awkward posture--further results from application of a simultaneous field measurement methodology.

    PubMed

    Raffler, Nastaran; Hermanns, Ingo; Sayn, Detlef; Göres, Benno; Ellegast, Rolf; Rissler, Jörg

    2010-01-01

    The drivers of ten vehicles (tram, helicopter, saloon car, van, forklift, two mobile excavators, wheel loader, tractor, elevating platform truck) were studied with regard to the combined exposures of whole-body vibration and awkward posture during occupational tasks. Seven degrees of freedom (DOFs), or body angles, were recorded as a function of time by means of the CUELA measuring system (Computer-assisted registration and long-term analysis of musculoskeletal workloads) for the purpose of posture assessment. The vibrational exposure is expressed as the vector sum of the frequency-weighted accelerations in the three Cartesian coordinates; these were recorded simultaneously with the posture measurement. Based upon the percentage of working time spent under different workloads, a scheme is proposed for classification of the two exposures into three categories. In addition, a risk of adverse health effects classified as low, possible or high can be assigned to the combination of the two exposures. With regard to posture, the most severe exposure was measured for the drivers of the wheel loader and for the tractor driver, whereas the lowest exposure was measured for the helicopter pilots and van drivers. With regard to the combination of whole-body and posture exposures, the tractor driver and the elevating platform truck driver exhibited the highest workloads.

  18. Pulse frequency and soil-litter mixing alter the control of cumulative precipitation over litter decomposition.

    PubMed

    Joly, François-Xavier; Kurupas, Kelsey L; Throop, Heather L

    2017-09-01

    Macroclimate has traditionally been considered the predominant driver of litter decomposition. However, in drylands, cumulative monthly or annual precipitation typically fails to predict decomposition. In these systems, the windows of opportunity for decomposer activity may rather depend on the precipitation frequency and local factors affecting litter desiccation, such as soil-litter mixing. We used a full-factorial microcosm experiment to disentangle the relative importance of cumulative precipitation, pulse frequency, and soil-litter mixing on litter decomposition. Decomposition, measured as litter carbon loss, saturated with increasing cumulative precipitation when pulses were large and infrequent, suggesting that litter moisture no longer increased and/or microbial activity was no longer limited by water availability above a certain pulse size. More frequent precipitation pulses led to increased decomposition at high levels of cumulative precipitation. Soil-litter mixing consistently increased decomposition, with greatest relative increase (+194%) under the driest conditions. Collectively, our results highlight the need to consider precipitation at finer temporal scale and incorporate soil-litter mixing as key driver of decomposition in drylands. © 2017 by the Ecological Society of America.

  19. Beam Instrument Development System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DOOLITTLE, LAWRENCE; HUANG, GANG; DU, QIANG

    Beam Instrumentation Development System (BIDS) is a collection of common support libraries and modules developed during a series of Low-Level Radio Frequency (LLRF) control and timing/synchronization projects. BIDS includes a collection of Hardware Description Language (HDL) libraries and software libraries. The BIDS can be used for the development of any FPGA-based system, such as LLRF controllers. HDL code in this library is generic and supports common Digital Signal Processing (DSP) functions, FPGA-specific drivers (high-speed serial link wrappers, clock generation, etc.), ADC/DAC drivers, Ethernet MAC implementation, etc.

  20. Driving Task: How Older Drivers' On-Road Driving Performance Relates to Abilities, Perceptions, and Restrictions.

    PubMed

    Koppel, Sjaan; Charlton, Judith L; Langford, Jim; Di Stefano, Marilyn; MacDonald, Wendy; Vlahodimitrakou, Zafiroula; Mazer, Barbara L; Gelinas, Isabelle; Vrkljan, Brenda; Eliasz, Kinga; Myers, Anita; Tuokko, Holly A; Marshall, Shawn C

    2016-06-01

    This study examined a cohort of 227 older drivers and investigated the relationship between performance on the electronic Driver Observation Schedule (eDOS) driving task and: (1) driver characteristics; (2) functional abilities; (3) perceptions of driving comfort and abilities; and (4) self-reported driving restrictions. Participants (male: 70%; age: M = 81.53 years, SD = 3.37 years) completed a series of functional ability measures and scales on perceived driving comfort, abilities, and driving restrictions from the Year 2 Candrive/Ozcandrive assessment protocol, along with an eDOS driving task. Observations of participants' driving behaviours during the driving task were recorded for intersection negotiation, lane-changing, merging, low-speed maneuvers, and maneuver-free driving. eDOS driving task scores were high (M = 94.74; SD = 5.70) and significantly related to participants' perceived driving abilities, reported frequency of driving in challenging situations, and number of driving restrictions. Future analyses will explore potential changes in driving task scores over time.

  1. Clonal status of actionable driver events and the timing of mutational processes in cancer evolution.

    PubMed

    McGranahan, Nicholas; Favero, Francesco; de Bruin, Elza C; Birkbak, Nicolai Juul; Szallasi, Zoltan; Swanton, Charles

    2015-04-15

    Deciphering whether actionable driver mutations are found in all or a subset of tumor cells will likely be required to improve drug development and precision medicine strategies. We analyzed nine cancer types to determine the subclonal frequencies of driver events, to time mutational processes during cancer evolution, and to identify drivers of subclonal expansions. Although mutations in known driver genes typically occurred early in cancer evolution, we also identified later subclonal "actionable" mutations, including BRAF (V600E), IDH1 (R132H), PIK3CA (E545K), EGFR (L858R), and KRAS (G12D), which may compromise the efficacy of targeted therapy approaches. More than 20% of IDH1 mutations in glioblastomas, and 15% of mutations in genes in the PI3K (phosphatidylinositol 3-kinase)-AKT-mTOR (mammalian target of rapamycin) signaling axis across all tumor types were subclonal. Mutations in the RAS-MEK (mitogen-activated protein kinase kinase) signaling axis were less likely to be subclonal than mutations in genes associated with PI3K-AKT-mTOR signaling. Analysis of late mutations revealed a link between APOBEC-mediated mutagenesis and the acquisition of subclonal driver mutations and uncovered putative cancer genes involved in subclonal expansions, including CTNNA2 and ATXN1. Our results provide a pan-cancer census of driver events within the context of intratumor heterogeneity and reveal patterns of tumor evolution across cancers. The frequent presence of subclonal driver mutations suggests the need to stratify targeted therapy response according to the proportion of tumor cells in which the driver is identified. Copyright © 2015, American Association for the Advancement of Science.

  2. Prevalence of teen driver errors leading to serious motor vehicle crashes.

    PubMed

    Curry, Allison E; Hafetz, Jessica; Kallan, Michael J; Winston, Flaura K; Durbin, Dennis R

    2011-07-01

    Motor vehicle crashes are the leading cause of adolescent deaths. Programs and policies should target the most common and modifiable reasons for crashes. We estimated the frequency of critical reasons for crashes involving teen drivers, and examined in more depth specific teen driver errors. The National Highway Traffic Safety Administration's (NHTSA) National Motor Vehicle Crash Causation Survey collected data at the scene of a nationally representative sample of 5470 serious crashes between 7/05 and 12/07. NHTSA researchers assigned a single driver, vehicle, or environmental factor as the critical reason for the event immediately leading to each crash. We analyzed crashes involving 15-18 year old drivers. 822 teen drivers were involved in 795 serious crashes, representing 335,667 teens in 325,291 crashes. Driver error was by far the most common reason for crashes (95.6%), as opposed to vehicle or environmental factors. Among crashes with a driver error, a teen made the error 79.3% of the time (75.8% of all teen-involved crashes). Recognition errors (e.g., inadequate surveillance, distraction) accounted for 46.3% of all teen errors, followed by decision errors (e.g., following too closely, too fast for conditions) (40.1%) and performance errors (e.g., loss of control) (8.0%). Inadequate surveillance, driving too fast for conditions, and distracted driving together accounted for almost half of all crashes. Aggressive driving behavior, drowsy driving, and physical impairments were less commonly cited as critical reasons. Males and females had similar proportions of broadly classified errors, although females were specifically more likely to make inadequate surveillance errors. Our findings support prioritization of interventions targeting driver distraction and surveillance and hazard awareness training. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Driver injury severity related to inclement weather at highway-rail grade crossings in the United States.

    PubMed

    Hao, Wei; Daniel, Janice

    2016-01-01

    Previous studies on crash modeling at highway-rail grade crossings were aimed at exploring the factors that are likely to increase the crash frequencies at highway-rail grade crossings. In recent years, modeling driver's injury severity at highway-rail grade crossings has received interest. Because there were substantial differences among different weather conditions for driver's injury severity, this study attempts to explore the impact of weather influence on driver injury at highway-rail grade crossing. Utilizing the most recent 10 years (2002-2011) of highway-rail grade crossing accident data, this study applied a mixed logit model to explore the determinants of driver injury severity under different weather conditions at highway-rail grade crossing. Analysis results indicate that drivers' injury severity at highway-rail grade crossings is strongly different for different weather conditions. It was found that the factors significantly impacting driver injury severity at highway-rail grade crossings include motor vehicle speed, train speed, driver's age, gender, area type, lighting condition, highway pavement, traffic volume, and time of day. The findings of this study indicate that crashes are more prevalent if vehicle drivers are driving at high speed or the oncoming trains are high speed. Hence, a reduction in speed limit during inclement weather conditions could be particularly effective in moderating injury severity, allowing more reaction time for last-minute maneuvering and braking in moments before impacts. In addition, inclement weather-related crashes were more likely to occur in open areas and highway-rail grade crossings without pavement and lighting. Paved highway-rail grade crossings with installation of lights could be particularly effective in moderating injury severity.

  4. Nucleolar Reorganization Upon Site-Specific Double-Strand Break Induction

    PubMed Central

    Franek, Michal; Kovaříková, Alena; Bártová, Eva; Kozubek, Stanislav

    2016-01-01

    DNA damage response (DDR) in ribosomal genes and mechanisms of DNA repair in embryonic stem cells (ESCs) are less explored nuclear events. DDR in ESCs should be unique due to their high proliferation rate, expression of pluripotency factors, and specific chromatin signature. Given short population doubling time and fast progress through G1 phase, ESCs require a sustained production of rRNA, which leads to the formation of large and prominent nucleoli. Although transcription of rRNA in the nucleolus is relatively well understood, little is known about DDR in this nuclear compartment. Here, we directed formation of double-strand breaks in rRNA genes with I-PpoI endonuclease, and we studied nucleolar morphology, DDR, and chromatin modifications. We observed a pronounced formation of I-PpoI-induced nucleolar caps, positive on BRCA1, NBS1, MDC1, γH2AX, and UBF1 proteins. We showed interaction of nucleolar protein TCOF1 with HDAC1 and TCOF1 with CARM1 after DNA injury. Moreover, H3R17me2a modification mediated by CARM1 was found in I-PpoI-induced nucleolar caps. Finally, we report that heterochromatin protein 1 is not involved in DNA repair of nucleolar caps. PMID:27680669

  5. A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interaction.

    PubMed

    Hing, James T; Brooks, Ari D; Desai, Jaydev P

    2007-02-01

    A methodology for modeling the needle and soft-tissue interaction during needle insertion is presented. The approach consists of the measurement of needle and tissue motion using a dual C-arm fluoroscopy system. Our dual C-arm fluoroscopy setup allows real time 3-D extraction of the displacement of implanted fiducials in the soft tissue during needle insertion to obtain the necessary parameters for accurate modeling of needle and soft-tissue interactions. The needle and implanted markers in the tissue are tracked during the insertion and withdrawal of the needle at speeds of 1.016 mm/s, 12.7 mm/s and 25.4 mm/s. Both image and force data are utilized to determine important parameters such as the approximate cutting force, puncture force, the local effective modulus (LEM) during puncture, and the relaxation of tissue. We have also validated the LEM computed from our finite element model with arbitrary needle puncture tasks. Based on these measurements, we developed a model for needle insertion and withdrawal that can be used to generate a 1-DOF force versus position profile that can be experienced by a user operating a haptic device. This profile was implemented on a 7-DOf haptic device designed in our laboratory.

  6. In vivo imaging of superficial femoral artery (SFA) stents for deformation analysis

    NASA Astrophysics Data System (ADS)

    Ganguly, A.; Schneider, A.; Keck, B.; Bennett, N. R.; Fahrig, R.

    2008-03-01

    A high-resolution (198 μm) C-arm CT imaging system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) was optimized for imaging superficial femoral artery (SFA) stents in humans. The SFA is susceptible to the development of atherosclerotic lesions. These are typically treated with angioplasty and stent deployment. However, these stents can have a fracture rate as high as 35%. Fracture is usually accompanied by restenosis and reocclusion. The exact cause of breakage is unknown and is hypothesized to result from deforming forces due to hip and knee flexion. Imaging was performed with the leg placed in both straight and bent positions. Projection images obtained during 20 s scans with ~200° of rotation of the C-arm were back-projected to obtain 3D volumes. Using a semi-automatic software algorithm developed in-house, the stent centerlines were found and ellipses were fitted to the slice normals. Image quality was adequate for calculations in 11/13 subjects. Bending the leg was found to shorten the stents in 10/11 cases with the maximum change being 9% (12 mm in a 133 mm stent), and extend the stent in one case by 1.6%. The maximum eccentricity change was 36% with a bend angle of 72° in a case where the stent extended behind the knee.

  7. Acceleration of fluoro-CT reconstruction for a mobile C-Arm on GPU and FPGA hardware: a simulation study

    NASA Astrophysics Data System (ADS)

    Xue, Xinwei; Cheryauka, Arvi; Tubbs, David

    2006-03-01

    CT imaging in interventional and minimally-invasive surgery requires high-performance computing solutions that meet operational room demands, healthcare business requirements, and the constraints of a mobile C-arm system. The computational requirements of clinical procedures using CT-like data are increasing rapidly, mainly due to the need for rapid access to medical imagery during critical surgical procedures. The highly parallel nature of Radon transform and CT algorithms enables embedded computing solutions utilizing a parallel processing architecture to realize a significant gain of computational intensity with comparable hardware and program coding/testing expenses. In this paper, using a sample 2D and 3D CT problem, we explore the programming challenges and the potential benefits of embedded computing using commodity hardware components. The accuracy and performance results obtained on three computational platforms: a single CPU, a single GPU, and a solution based on FPGA technology have been analyzed. We have shown that hardware-accelerated CT image reconstruction can be achieved with similar levels of noise and clarity of feature when compared to program execution on a CPU, but gaining a performance increase at one or more orders of magnitude faster. 3D cone-beam or helical CT reconstruction and a variety of volumetric image processing applications will benefit from similar accelerations.

  8. Aberrant Behaviors and Road Accidents among Iranian Truck Drivers, 2010.

    PubMed

    Ketabi, Damon; Barkhordari, Abalfazl; Mirmohammadi, Seyyed Jalil; Mehrparvar, Amir Houshang

    2011-01-01

    Road accidents are a social phenomenon in different communities that its infra-structural dimensions of which as well as technologic failures such as road quality, and tech-nical faults of automobiles, need to be assessed in detail. Iran has the first order in the world for deadly road accidents. This study was designed to assess the association between aberrant behaviors of truck drivers and the incidence of road accidents in Yazd, center of Iran, in 2010. This cross-sectional descriptive-analytic study was conducted on 300 truck drivers in Yazd. We used 3 questionnaires, including one for demographic data, Driver Behavior Questionnaire (DBQ), and one for drivers' self-evaluation of the of their driving. Five types of the behavior had the highest frequency: Misjudge speed of oncoming vehicle when overtaking.; Deliberately disregard the speed limits late at night or very early in the morning.; Ignore 'give way' signs, and narrowly avoid colliding with traffic having right of way.; Stuck behind a slow-moving vehicle on a two-lane highway, you are driven by frustration to try to overtake in risky circumstances.; Drive with only 'half-an-eye' on the road while looking at a map, changing a cassette or radio channel, etc. The more the driver's driv-ing was influenced by emotional and mental states the more deliberate violations and slips. Among truck drivers, safety has not developed sufficiently, and because of the dangers of road accidents both for the drivers and other people and its economic losses, the importance of the presenting some solutions is completely obvious.

  9. Exploring the Origin of Kinematically Irregular Galaxies with MaNGA

    NASA Astrophysics Data System (ADS)

    Stark, David Vincent; Bundy, Kevin; Westfall, Kyle; Bershady, Matthew; Cheung, Edmond; Soler, Juan; Brinchmann, Jarle; Abraham, Roberto; Bizyaev, Dmitry; Masters, Karen; Weijmans, Anne-Marie; Chen, Yanmei; Jin, Yifei; Drory, Niv; Lopes, Alexandre Roman; Law, David

    2018-01-01

    Deviations from normal rotation in galaxies may have a number of potential drivers, including tidal interactions, gas inflows/outflows, spiral structure, bar/oval distortions, or other internally generated instabilities. Thanks to new massive IFU surveys like MaNGA, we can now characterize the gas and stellar kinematics of thousands of galaxies in the local universe, enabling statistical analyses on the frequency of disturbed kinematics, their origin, and their impact on their host galaxies. We present a census of kinematics in MaNGA using a modified version of the Radon transform to map radial variations in kinematic position angles (PA). We discuss the frequency of kinematically irregular disks, and describe commonly observed patterns in radial PA profiles. In order to constrain the drivers of these kinematic signatures, we analyze how they correlate with galaxy mass, environment, star formation history, and gas-phase metallicity.

  10. Climatic Signals from Intra-annual Density Fluctuation Frequency in Mediterranean Pines at a Regional Scale

    PubMed Central

    Zalloni, Enrica; de Luis, Martin; Campelo, Filipe; Novak, Klemen; De Micco, Veronica; Di Filippo, Alfredo; Vieira, Joana; Nabais, Cristina; Rozas, Vicente; Battipaglia, Giovanna

    2016-01-01

    Tree rings provide information about the climatic conditions during the growing season by recording them in different anatomical features, such as intra-annual density fluctuations (IADFs). IADFs are intra-annual changes of wood density appearing as latewood-like cells within earlywood, or earlywood-like cells within latewood. The occurrence of IADFs is dependent on the age and size of the tree, and it is triggered by climatic drivers. The variations of IADF frequency of different species and their dependence on climate across a wide geographical range have still to be explored. The objective of this study is to investigate the effect of age, tree-ring width and climate on IADF formation and frequency at a regional scale across the Mediterranean Basin in Pinus halepensis Mill., Pinus pinaster Ait., and Pinus pinea L. The analyzed tree-ring network was composed of P. pinea trees growing at 10 sites (2 in Italy, 4 in Spain, and 4 in Portugal), P. pinaster from 19 sites (2 in Italy, 13 in Spain, and 4 in Portugal), and P. halepensis from 38 sites in Spain. The correlations between IADF frequency and monthly minimum, mean and maximum temperatures, as well as between IADF frequency and total precipitation, were analyzed. A significant negative relationship between IADF frequency and tree-ring age was found for the three Mediterranean pines. Moreover, IADFs were more frequent in wider rings than in narrower ones, although the widest rings showed a reduced IADF frequency. Wet conditions during late summer/early autumn triggered the formation of IADFs in the three species. Our results suggest the existence of a common climatic driver for the formation of IADFs in Mediterranean pines, highlighting the potential use of IADF frequency as a proxy for climate reconstructions with geographical resolution. PMID:27200052

  11. High frequency generation in the corona: Resonant cavities

    NASA Astrophysics Data System (ADS)

    Santamaria, I. C.; Van Doorsselaere, T.

    2018-03-01

    Aims: Null points are prominent magnetic field singularities in which the magnetic field strength strongly decreases in very small spatial scales. Around null points, predicted to be ubiquitous in the solar chromosphere and corona, the wave behavior changes considerably. Null points are also responsible for driving very energetic phenomena, and for contributing to chromospheric and coronal heating. In previous works we demonstrated that slow magneto-acoustic shock waves were generated in the chromosphere propagate through the null point, thereby producing a train of secondary shocks escaping along the field lines. A particular combination of the shock wave speeds generates waves at a frequency of 80 MHz. The present work aims to investigate this high frequency region around a coronal null point to give a plausible explanation to its generation at that particular frequency. Methods: We carried out a set of two-dimensional numerical simulations of wave propagation in the neighborhood of a null point located in the corona. We varied both the amplitude of the driver and the atmospheric properties to investigate the sensitivity of the high frequency waves to these parameters. Results: We demonstrate that the wave frequency is sensitive to the atmospheric parameters in the corona, but it is independent of the strength of the driver. Thus, the null point behaves as a resonant cavity generating waves at specific frequencies that depend on the background equilibrium model. Moreover, we conclude that the high frequency wave train generated at the null point is not necessarily a result of the interaction between the null point and a shock wave. This wave train can be also developed by the interaction between the null point and fast acoustic-like magneto-acoustic waves, that is, this interaction within the linear regime.

  12. Car driver attitudes, perceptions of social norms and aggressive driving behaviour towards cyclists.

    PubMed

    Fruhen, Laura S; Flin, Rhona

    2015-10-01

    The interaction of car drivers and cyclists is one of the main causes of cycle incidents. The role of attitudes and social norms in shaping car drivers' aggressive behaviour towards cyclists, is not well understood and merits investigation. A sample of 276 drivers completed an online questionnaire concerning their attitudes towards cyclists, attitudes towards risky driving, perception of social norms concerning aggressive driving towards cyclists, and the frequency with which they engage in such aggressive driving behaviours. The results showed that attitudes towards cyclists, as well as social norm perceptions concerning aggressive driving towards cyclists, were associated with aggressive driving towards cyclists. Negative attitudes towards cyclists were more pronounced in non-cyclists than cyclists and their association with aggressive driving behaviour was stronger in cyclists than non-cyclists. The perception of social norms concerning aggressive driving towards cyclists had a stronger association with aggressive driving in non-cyclists than cyclists. Attitudes towards risk taking did not affect aggressive driving towards cyclists. These findings can inform campaigns that aim to improve cyclist and car driver interaction on the roads, making them safer to use for cyclists. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Traffic-law enforcement and risk of death from motor-vehicle crashes: case-crossover study.

    PubMed

    Redelmeier, Donald A; Tibshirani, Robert J; Evans, Leonard

    2003-06-28

    Driving offences and traffic deaths are common in countries with high rates of motor-vehicle use. We tested whether traffic convictions, because of their direct effect on the recipient, might be associated with a reduced risk of fatal motor-vehicle crashes. We identified licensed drivers in Ontario, Canada, who had been involved in fatal crashes in the past 11 years. We used the case-crossover design to analyse the protective effect of recent convictions on individual drivers. 8975 licensed drivers had fatal crashes during the study period. 21501 driving convictions were recorded for all drivers from the date of obtaining a full licence to the date of fatal crash, equivalent to about one conviction per driver every 5 years. The risk of a fatal crash in the month after a conviction was about 35% lower than in a comparable month with no conviction for the same driver (95% CI 20-45, p=0.0002). The benefit lessened substantially by 2 months and was not significant by 3-4 months. The benefit was not altered by age, previous convictions, and other personal characteristics; was greater for speeding violations with penalty points than speeding violations without points; was no different for crashes of differing severity; and was not seen in drivers whose licences were suspended. Traffic-law enforcement effectively reduces the frequency of fatal motor-vehicle crashes in countries with high rates of motor-vehicle use. Inconsistent enforcement, therefore, may contribute to thousands of deaths each year worldwide.

  14. Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, Kerstin; Schwemmer, Chris; Hornegger, Joachim

    2013-03-15

    Purpose: For interventional cardiac procedures, anatomical and functional information about the cardiac chambers is of major interest. With the technology of angiographic C-arm systems it is possible to reconstruct intraprocedural three-dimensional (3D) images from 2D rotational angiographic projection data (C-arm CT). However, 3D reconstruction of a dynamic object is a fundamental problem in C-arm CT reconstruction. The 2D projections are acquired over a scan time of several seconds, thus the projection data show different states of the heart. A standard FDK reconstruction algorithm would use all acquired data for a filtered backprojection and result in a motion-blurred image. In thismore » approach, a motion compensated reconstruction algorithm requiring knowledge of the 3D heart motion is used. The motion is estimated from a previously presented 3D dynamic surface model. This dynamic surface model results in a sparse motion vector field (MVF) defined at control points. In order to perform a motion compensated reconstruction, a dense motion vector field is required. The dense MVF is generated by interpolation of the sparse MVF. Therefore, the influence of different motion interpolation methods on the reconstructed image quality is evaluated. Methods: Four different interpolation methods, thin-plate splines (TPS), Shepard's method, a smoothed weighting function, and a simple averaging, were evaluated. The reconstruction quality was measured on phantom data, a porcine model as well as on in vivo clinical data sets. As a quality index, the 2D overlap of the forward projected motion compensated reconstructed ventricle and the segmented 2D ventricle blood pool was quantitatively measured with the Dice similarity coefficient and the mean deviation between extracted ventricle contours. For the phantom data set, the normalized root mean square error (nRMSE) and the universal quality index (UQI) were also evaluated in 3D image space. Results: The quantitative evaluation of all experiments showed that TPS interpolation provided the best results. The quantitative results in the phantom experiments showed comparable nRMSE of Almost-Equal-To 0.047 {+-} 0.004 for the TPS and Shepard's method. Only slightly inferior results for the smoothed weighting function and the linear approach were achieved. The UQI resulted in a value of Almost-Equal-To 99% for all four interpolation methods. On clinical human data sets, the best results were clearly obtained with the TPS interpolation. The mean contour deviation between the TPS reconstruction and the standard FDK reconstruction improved in the three human cases by 1.52, 1.34, and 1.55 mm. The Dice coefficient showed less sensitivity with respect to variations in the ventricle boundary. Conclusions: In this work, the influence of different motion interpolation methods on left ventricle motion compensated tomographic reconstructions was investigated. The best quantitative reconstruction results of a phantom, a porcine, and human clinical data sets were achieved with the TPS approach. In general, the framework of motion estimation using a surface model and motion interpolation to a dense MVF provides the ability for tomographic reconstruction using a motion compensation technique.« less

  15. Vehicle manoeuvers as surrogate safety measures: Extracting data from the gps-enabled smartphones of regular drivers.

    PubMed

    Stipancic, Joshua; Miranda-Moreno, Luis; Saunier, Nicolas

    2018-06-01

    Network screening is a key element in identifying and prioritizing hazardous sites for engineering treatment. Traditional screening methods have used observed crash frequency or severity ranking criteria and statistical modelling approaches, despite the fact that crash-based methods are reactive. Alternatively, surrogate safety measures (SSMs) have become popular, making use of new data sources including video and, more rarely, GPS data. The purpose of this study is to examine vehicle manoeuvres of braking and accelerating extracted from a large quantity of GPS data collected using the smartphones of regular drivers, and to explore their potential as SSMs through correlation with historical collision frequency and severity across different facility types. GPS travel data was collected in Quebec City, Canada in 2014. The sample for this study contained over 4000 drivers and 21,000 trips. Hard braking (HBEs) and accelerating events (HAEs) were extracted and compared to historical crash data using Spearman's correlation coefficient and pairwise Kolmogorov-Smirnov tests. Both manoeuvres were shown to be positively correlated with crash frequency at the link and intersection levels, though correlations were much stronger when considering intersections. Locations with more braking and accelerating also tend to have more collisions. Concerning severity, higher numbers of vehicle manoeuvres were also related to increased collision severity, though this relationship was not always statistically significant. The inclusion of severity testing, which is an independent dimension of safety, represents a substantial contribution to the existing literature. Future work will focus on developing a network screening model that incorporates these SSMs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Monolithic device for modelocking and stabilization of frequency combs.

    PubMed

    Lee, C-C; Hayashi, Y; Silverman, K L; Feldman, A; Harvey, T; Mirin, R P; Schibli, T R

    2015-12-28

    We demonstrate a device that integrates a III-V semiconductor saturable absorber mirror with a graphene electro-optic modulator, which provides a monolithic solution to modelocking and noise suppression in a frequency comb. The device offers a pure loss modulation bandwidth exceeding 5 MHz and only requires a low voltage driver. This hybrid device provides not only compactness and simplicity in laser cavity design, but also small insertion loss, compared to the previous metallic-mirror-based modulators. We believe this work paves the way to portable and fieldable phase-coherent frequency combs.

  17. Analysis of impact noise induced by hitting of titanium head golf driver.

    PubMed

    Kim, Young Ho; Kim, Young Chul; Lee, Jun Hee; An, Yong-Hwi; Park, Kyung Tae; Kang, Kyung Min; Kang, Yeon June

    2014-11-01

    The hitting of titanium head golf driver against golf ball creates a short duration, high frequency impact noise. We analyzed the spectra of these impact noises and evaluated the auditory hazards from exposure to the noises. Noises made by 10 titanium head golf drivers with five maximum hits were collected, and the spectra of the pure impact sounds were studied using a noise analysis program. The noise was measured at 1.7 m (position A) and 3.4 m (position B) from the hitting point in front of the hitter and at 3.4 m (position C) behind the hitting point. Average time duration was measured and auditory risk units (ARUs) at position A were calculated using the Auditory Hazard Assessment Algorithm for Humans. The average peak levels at position A were 119.9 dBA at the sound pressure level (SPL) peak and 100.0 dBA at the overall octave level. The average peak levels (SPL and overall octave level) at position B were 111.6 and 96.5 dBA, respectively, and at position C were 111.5 and 96.7 dBA, respectively. The average time duration and ARUs measured at position A were 120.6 ms and 194.9 units, respectively. Although impact noises made by titanium head golf drivers showed relatively low ARUs, individuals enjoying golf frequently may be susceptible to hearing loss due to the repeated exposure of this intense impact noise with short duration and high frequency. Unprotected exposure to impact noises should be limited to prevent cochleovestibular disorders.

  18. Comprehensive investigation of oncogenic driver mutations in Chinese non-small cell lung cancer patients.

    PubMed

    Wang, Rui; Zhang, Yang; Pan, Yunjian; Li, Yuan; Hu, Haichuan; Cai, Deng; Li, Hang; Ye, Ting; Luo, Xiaoyang; Zhang, Yiliang; Li, Bin; Shen, Lei; Sun, Yihua; Chen, Haiquan

    2015-10-27

    To determine the frequency of driver mutations in Chinese non-small cell lung cancer (NSCLC) patients. Comprehensive mutational analysis was performed in 1356 lung adenocarcinoma, 503 squamous cell carcinoma, 57 adenosquamous lung carcinoma, 19 large cell carcinoma and 8 sarcomatoid carcinoma. The effect of EGFR tyrosine kinase inhibitors (TKIs) on EGFR-mutated lung adenocarcinoma patients after disease recurrence was investigated. Mutations in EGFR kinase domain, HER2 kinase domain, KRAS, BRAF, ALK, ROS1 and RET were mutually exclusive. In lung adenocarcinoma cases "pan-negative" for the seven above-mentioned driver mutations, we also detected two oncogenic EGFR extracellular domain mutations (A289D and R324L), two HER2 extracellular and transmembrane domain mutations (S310Y and V659E), one ARAF S214C mutation and two CD74-NRG1 fusions. Six (1.2%) FGFR3 activating mutations were identified in lung squamous cell carcinoma (five S249C and one R248C). There were three (15.8%) EGFR mutations and four (21.1%) KRAS mutations in large cell carcinoma. Three (37.5%) KRAS mutations were detected in sarcomatoid carcinoma. In EGFR-mutated lung adenocarcinoma patients who experienced disease recurrence, treatment with EGFR TKIs was an independent predictor of better overall survival (HR = 0.299, 95% CI: 0.172-0.519, P < 0.001). We determined the frequency of driver mutations in a large series of Chinese NSCLC patients. EGFR TKIs might improve the survival outcomes of EGFR-mutated lung adenocarcinoma patients who experienced disease recurrence.

  19. TU-AB-204-03: Advances in CBCT for Orhtopaedics and Bone Health Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zbijewski, W.

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both themore » likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)« less

  20. TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both themore » likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)« less

  1. TU-AB-204-04: Advances in CBCT for Breast Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boone, J.

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both themore » likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)« less

  2. Evaluating the need for surface treatments to reduce crash frequency on horizontal curves.

    DOT National Transportation Integrated Search

    2013-10-01

    The application of high-friction surface treatments at appropriate horizontal curve locations throughout the : state has the potential to improve driver performance and reduce the number of crashes experienced at : horizontal curves. These treatments...

  3. High Frequency Monitoring for Harmful Algal Blooms

    EPA Science Inventory

    Harmful algal blooms (HABs) are increasingly becoming a significant ecologic, economic, and social driver in the use of water resources. Cyanobacteria and their toxins play an important role in management decisions for drinking water utilities and public health officials. Online ...

  4. Deep-Space Optical Communications: Visions, Trends, and Prospects

    NASA Technical Reports Server (NTRS)

    Cesarone, R. J.; Abraham, D. S.; Shambayati, S.; Rush, J.

    2011-01-01

    Current key initiatives in deep-space optical communications are treated in terms of historical context, contemporary trends, and prospects for the future. An architectural perspective focusing on high-level drivers, systems, and related operations concepts is provided. Detailed subsystem and component topics are not addressed. A brief overview of past ideas and architectural concepts sets the stage for current developments. Current requirements that might drive a transition from radio frequencies to optical communications are examined. These drivers include mission demand for data rates and/or data volumes; spectrum to accommodate such data rates; and desired power, mass, and cost benefits. As is typical, benefits come with associated challenges. For optical communications, these include atmospheric effects, link availability, pointing, and background light. The paper describes how NASA's Space Communication and Navigation Office will respond to the drivers, achieve the benefits, and mitigate the challenges, as documented in its Optical Communications Roadmap. Some nontraditional architectures and operations concepts are advanced in an effort to realize benefits and mitigate challenges as quickly as possible. Radio frequency communications is considered as both a competitor to and a partner with optical communications. The paper concludes with some suggestions for two affordable first steps that can yet evolve into capable architectures that will fulfill the vision inherent in optical communications.

  5. Deconstructing Demand: The Anthropogenic and Climatic Drivers of Urban Water Consumption.

    PubMed

    Hemati, Azadeh; Rippy, Megan A; Grant, Stanley B; Davis, Kristen; Feldman, David

    2016-12-06

    Cities in drought prone regions of the world such as South East Australia are faced with escalating water scarcity and security challenges. Here we use 72 years of urban water consumption data from Melbourne, Australia, a city that recently overcame a 12 year "Millennium Drought", to evaluate (1) the relative importance of climatic and anthropogenic drivers of urban water demand (using wavelet-based approaches) and (2) the relative contribution of various water saving strategies to demand reduction during the Millennium Drought. Our analysis points to conservation as a dominant driver of urban water savings (69%), followed by nonrevenue water reduction (e.g., reduced meter error and leaks in the potable distribution system; 29%), and potable substitution with alternative sources like rain or recycled water (3%). Per-capita consumption exhibited both climatic and anthropogenic signatures, with rainfall and temperature explaining approximately 55% of the variance. Anthropogenic controls were also strong (up to 45% variance explained). These controls were nonstationary and frequency-specific, with conservation measures like outdoor water restrictions impacting seasonal water use and technological innovation/changing social norms impacting lower frequency (baseline) use. The above-noted nonstationarity implies that wavelets, which do not assume stationarity, show promise for use in future predictive models of demand.

  6. Does polyandry control population sex ratio via regulation of a selfish gene?

    PubMed

    Price, Tom A R; Bretman, Amanda; Gradilla, Ana C; Reger, Julia; Taylor, Michelle L; Giraldo-Perez, Paulina; Campbell, Amy; Hurst, Gregory D D; Wedell, Nina

    2014-05-22

    The extent of female multiple mating (polyandry) can strongly impact on the intensity of sexual selection, sexual conflict, and the evolution of cooperation and sociality. More subtly, polyandry may protect populations against intragenomic conflicts that result from the invasion of deleterious selfish genetic elements (SGEs). SGEs commonly impair sperm production, and so are likely to be unsuccessful in sperm competition, potentially reducing their transmission in polyandrous populations. Here, we test this prediction in nature. We demonstrate a heritable latitudinal cline in the degree of polyandry in the fruitfly Drosophila pseudoobscura across the USA, with northern population females remating more frequently in both the field and the laboratory. High remating was associated with low frequency of a sex-ratio-distorting meiotic driver in natural populations. In the laboratory, polyandry directly controls the frequency of the driver by undermining its transmission. Hence we suggest that the cline in polyandry represents an important contributor to the cline in sex ratio in nature. Furthermore, as the meiotic driver causes sex ratio bias, variation in polyandry may ultimately determine population sex ratio across the USA, a dramatic impact of female mating decisions. As SGEs are ubiquitous it is likely that the reduction of intragenomic conflict by polyandry is widespread.

  7. Dynamic Confinement of ITER Plasma by O-Mode Driver at Electron Cyclotron Frequency Range

    NASA Astrophysics Data System (ADS)

    Stefan, V. Alexander

    2009-05-01

    A low B-field side launched electron cyclotron O-Mode driver leads to the dynamic rf confinement, in addition to rf turbulent heating, of ITER plasma. The scaling law for the local energy confinement time τE is evaluated (τE ˜ 3neTe/2Q, where (3/2) neTe is the local plasma thermal energy density and Q is the local rf turbulent heating rate). The dynamics of unstable dissipative trapped particle modes (DTPM) strongly coupled to Trivelpiece-Gould (T-G) modes is studied for gyrotron frequency 170GHz; power˜24 MW CW; and on-axis B-field ˜ 10T. In the case of dynamic stabilization of DTPM turbulence and for the heavily damped T-G modes, the energy confinement time scales as τE˜(I0)-2, whereby I0(W/m^2) is the O-Mode driver irradiance. R. Prater et. al., Nucl. Fusion 48, No 3 (March 2008). E. P. Velikhov, History of the Russian Tokamak and the Tokamak Thermonuclear Fusion Research Worldwide That Led to ITER (Documentary movie; Stefan Studios Int'l, La Jolla, CA, 2008; E. P. Velikhov, V. Stefan.) M N Rosenbluth, Phys. Scr. T2A 104-109 1982 B. B. Kadomtsev and O. P. Pogutse, Nucl. Fusion 11, 67 (1971).

  8. Understanding the role of sleep quality and sleep duration in commercial driving safety.

    PubMed

    Lemke, Michael K; Apostolopoulos, Yorghos; Hege, Adam; Sönmez, Sevil; Wideman, Laurie

    2016-12-01

    Long-haul truck drivers in the United States suffer disproportionately high injury rates. Sleep is a critical factor in these outcomes, contributing to fatigue and degrading multiple aspects of safety-relevant performance. Both sleep duration and sleep quality are often compromised among truck drivers; however, much of the efforts to combat fatigue focus on sleep duration rather than sleep quality. Thus, the current study has two objectives: (1) to determine the degree to which sleep impacts safety-relevant performance among long-haul truck drivers; and (2) to evaluate workday and non-workday sleep quality and duration as predictors of drivers' safety-relevant performance. A non-experimental, descriptive, cross-sectional design was employed to collect survey and biometric data from 260 long-haul truck drivers. The Trucker Sleep Disorders Survey was developed to assess sleep duration and quality, the impact of sleep on job performance and accident risk, and other relevant work organization characteristics. Descriptive statistics assessed work organization variables, sleep duration and quality, and frequency of engaging in safety-relevant performance while sleepy. Linear regression analyses were conducted to evaluate relationships between sleep duration, sleep quality, and work organization variables with safety composite variables. Drivers reported long work hours, with over 70% of drivers working more than 11h daily. Drivers also reported a large number of miles driven per week, with an average of 2,812.61 miles per week, and frequent violations of hours-of-service rules, with 43.8% of drivers "sometimes to always" violating the "14-h rule." Sleep duration was longer, and sleep quality was better, on non-workdays compared on workdays. Drivers frequently operated motor vehicles while sleepy, and sleepiness impacted several aspects of safety-relevant performance. Sleep quality was better associated with driving while sleepy and with job performance and concentration than sleep duration. Sleep duration was better associated with accidents and accident risk than sleep quality. Sleep quality appears to be better associated with safety-relevant performance among long-haul truck drivers than sleep duration. Comprehensive and multilevel efforts are needed to meaningfully address sleep quality among drivers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. A parametric duration model of the reaction times of drivers distracted by mobile phone conversations.

    PubMed

    Haque, Md Mazharul; Washington, Simon

    2014-01-01

    The use of mobile phones while driving is more prevalent among young drivers-a less experienced cohort with elevated crash risk. The objective of this study was to examine and better understand the reaction times of young drivers to a traffic event originating in their peripheral vision whilst engaged in a mobile phone conversation. The CARRS-Q advanced driving simulator was used to test a sample of young drivers on various simulated driving tasks, including an event that originated within the driver's peripheral vision, whereby a pedestrian enters a zebra crossing from a sidewalk. Thirty-two licensed drivers drove the simulator in three phone conditions: baseline (no phone conversation), hands-free and handheld. In addition to driving the simulator each participant completed questionnaires related to driver demographics, driving history, usage of mobile phones while driving, and general mobile phone usage history. The participants were 21-26 years old and split evenly by gender. Drivers' reaction times to a pedestrian in the zebra crossing were modelled using a parametric accelerated failure time (AFT) duration model with a Weibull distribution. Also tested where two different model specifications to account for the structured heterogeneity arising from the repeated measures experimental design. The Weibull AFT model with gamma heterogeneity was found to be the best fitting model and identified four significant variables influencing the reaction times, including phone condition, driver's age, license type (provisional license holder or not), and self-reported frequency of usage of handheld phones while driving. The reaction times of drivers were more than 40% longer in the distracted condition compared to baseline (not distracted). Moreover, the impairment of reaction times due to mobile phone conversations was almost double for provisional compared to open license holders. A reduction in the ability to detect traffic events in the periphery whilst distracted presents a significant and measurable safety concern that will undoubtedly persist unless mitigated. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Comparison of teen and adult driver crash scenarios in a nationally representative sample of serious crashes.

    PubMed

    McDonald, Catherine C; Curry, Allison E; Kandadai, Venk; Sommers, Marilyn S; Winston, Flaura K

    2014-11-01

    Motor vehicle crashes are the leading cause of death and acquired disability during the first four decades of life. While teen drivers have the highest crash risk, few studies examine the similarities and differences in teen and adult driver crashes. We aimed to: (1) identify and compare the most frequent crash scenarios-integrated information on a vehicle's movement prior to crash, immediate pre-crash event, and crash configuration-for teen and adult drivers involved in serious crashes, and (2) for the most frequent scenarios, explore whether the distribution of driver critical errors differed for teens and adult drivers. We analyzed data from the National Motor Vehicle Crash Causation Survey, a nationally representative study of serious crashes conducted by the U.S. National Highway Traffic Safety Administration from 2005 to 2007. Our sample included 642 16- to 19-year-old and 1167 35- to 54-year-old crash-involved drivers (weighted n=296,482 and 439,356, respectively) who made a critical error that led to their crash's critical pre-crash event (i.e., event that made the crash inevitable). We estimated prevalence ratios (PR) and 95% confidence intervals (CI) to compare the relative frequency of crash scenarios and driver critical errors. The top five crash scenarios among teen drivers, accounting for 37.3% of their crashes, included: (1) going straight, other vehicle stopped, rear end; (2) stopped in traffic lane, turning left at intersection, turn into path of other vehicle; (3) negotiating curve, off right edge of road, right roadside departure; (4) going straight, off right edge of road, right roadside departure; and (5) stopped in lane, turning left at intersection, turn across path of other vehicle. The top five crash scenarios among adult drivers, accounting for 33.9% of their crashes, included the same scenarios as the teen drivers with the exception of scenario (3) and the addition of going straight, crossing over an intersection, and continuing on a straight path. For two scenarios ((1) and (3) above), teens were more likely than adults to make a critical decision error (e.g., traveling too fast for conditions). Our findings indicate that among those who make a driver critical error in a serious crash, there are few differences in the scenarios or critical driver errors for teen and adult drivers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Sitting biomechanics, part II: optimal car driver's seat and optimal driver's spinal model.

    PubMed

    Harrison, D D; Harrison, S O; Croft, A C; Harrison, D E; Troyanovich, S J

    2000-01-01

    Driving has been associated with signs and symptoms caused by vibrations. Sitting causes the pelvis to rotate backwards and the lumbar lordosis to reduce. Lumbar support and armrests reduce disc pressure and electromyographically recorded values. However, the ideal driver's seat and an optimal seated spinal model have not been described. To determine an optimal automobile seat and an ideal spinal model of a driver. Information was obtained from peer-reviewed scientific journals and texts, automotive engineering reports, and the National Library of Medicine. Driving predisposes vehicle operators to low-back pain and degeneration. The optimal seat would have an adjustable seat back incline of 100 degrees from horizontal, a changeable depth of seat back to front edge of seat bottom, adjustable height, an adjustable seat bottom incline, firm (dense) foam in the seat bottom cushion, horizontally and vertically adjustable lumbar support, adjustable bilateral arm rests, adjustable head restraint with lordosis pad, seat shock absorbers to dampen frequencies in the 1 to 20 Hz range, and linear front-back travel of the seat enabling drivers of all sizes to reach the pedals. The lumbar support should be pulsating in depth to reduce static load. The seat back should be damped to reduce rebounding of the torso in rear-end impacts. The optimal driver's spinal model would be the average Harrison model in a 10 degrees posterior inclining seat back angle.

  12. The wrist of the formula 1 driver

    PubMed Central

    Masmejean, E. H.; Chavane, H.; Chantegret, A.; Issermann, J. J.; Alnot, J. Y.

    1999-01-01

    OBJECTIVES: During formula 1 driving, repetitive cumulative trauma may provoke nerve disorders such as nerve compression syndrome as well as osteoligament injuries. A study based on interrogatory and clinical examination of 22 drivers was carried out during the 1998 formula 1 World Championship in order to better define the type and frequency of these lesions. METHODS: The questions investigated nervous symptoms, such as paraesthesia and diminishment of sensitivity, and osteoligamentous symptoms, such as pain, specifying the localisation (ulnar side, dorsal aspect of the wrist, snuff box) and the effect of the wrist position on the intensity of the pain. Clinical examination was carried out bilaterally and symmetrically. RESULTS: Fourteen of the 22 drivers reported symptoms. One suffered cramp in his hands at the end of each race and one described a typical forearm effort compartment syndrome. Six drivers had effort "osteoligamentous" symptoms: three scapholunate pain; one medial hypercompression of the wrist; two sequellae of a distal radius fracture. Seven reported nerve disorders: two effort carpal tunnel syndromes; one typical carpal tunnel syndrome; one effort cubital tunnel syndrome; three paraesthesia in all fingers at the end of a race, without any objective signs. CONCLUSIONS: This appears to be the first report of upper extremity disorders in competition drivers. The use of a wrist pad to reduce the effects of vibration may help to prevent trauma to the wrist in formula 1 drivers. 


 PMID:10450483

  13. Seat belt and child seat use in Lipetskaya Oblast, Russia: frequencies, attitudes, and perceptions.

    PubMed

    Ma, Sai; Tran, Nhan; Klyavin, Vladimir E; Zambon, Francesco; Hatcher, Kristin W; Hyder, Adnan A

    2012-01-01

    Despite the importance of understanding seat belt use patterns among drivers and passengers for the purpose of direct interventions or monitoring improvements, no study has described wearing rates for all seat positions in Russia. This study describes observed seat belt use and knowledge, attitudes, and perceptions of seat belt use in Lipetskaya Oblast, Russia. An observational study on the use of seat belts and child restraints in the Lipetskaya region conducted during October 2010 collected data in 6 districts and on 3 different road types. A roadside survey gathered information on knowledge, attitudes, and perceptions toward the use of seat belts from randomly selected drivers. Frequencies of seat belt use by seat position, gender, and road type were calculated. A multivariable logit model disclosed the associations between seat belt use and sociodemographic factors. The study design permitted comparison of observed seat belt use to self-reported seat belt use. A total of 25,795 vehicles and 39,833 drivers and passengers contributed observations. Overall, 55 percent of drivers were observed to be using seat belts. More than half (58%) of front seat passengers wore seat belts and only 9 percent of back seat passengers were observed to be wearing seat belts; 11 percent of cars with children had any type of child safety measure. Drivers on urban roads were less likely to wear seat belts compared to those on main highways and rural roads. Nearly 60 percent of survey respondents mentioned "seat belts save lives," and more than half mentioned law requirements and fines. Although the observed seat belt use in Lipetskaya Oblast is much higher than previous estimates in Russia, overall wearing rates remain far from universal. Rear seat passengers and children are particularly at risk. Because combined education and enforcement has proven to be effective elsewhere, such interventions are needed to improve seat belt use.

  14. The Influence of Road Bumps Characteristics on the Chaotic Vibration of a Nonlinear Full-Vehicle Model with Driver

    NASA Astrophysics Data System (ADS)

    Fakhraei, J.; Khanlo, H. M.; Ghayour, M.; Faramarzi, Kh.

    In this paper, the chaotic behavior of a ground vehicle system with driver subjected to road disturbances is studied and the relationship between the nonlinear vibration of the vehicle and ride comfort is evaluated. The vehicle system is modeled as fully nonlinear with seven degrees of freedom and an additional degree of freedom for driver (8-DOF). The excitation force is the road irregularities that are assumed as road speed control bumps. The sinusoidal, consecutive half-sine and dented-rectangular waveforms are considered to simulate the road speed control bumps. The nonlinearities of the system are due to the nonlinear springs and dampers that are used in the suspension system and tires. The governing differential equations are extracted under Newton-Euler laws and solved via numerical methods. The chaotic behaviors were studied in more detail with special techniques such as bifurcation diagrams, phase plane portrait, Poincaré map and Lyapunov exponents. The ride comfort was evaluated as the RMS value of the vertical displacement of the vehicle body and driver. Firstly, the effect of amplitude (height) and frequency (vehicle’s speed) of these speed control bumps on chaotic vibrations of vehicle are studied. The obtained results show that various forms of vibrations, such as periodic, subharmonic and chaotic vibrations, can be detected in the system behavior with the change of the height and frequency of speed control bumps and present different types of strange attractors in the vehicle with and without driver. Then, the influence of nonlinear vibration on ride comfort and the relationship between chaotic vibrations of the vehicle and driving comfort are investigated. The results of analyzing the RMS diagrams reveal that the chaotic behaviors can directly affect the driving comfort and lead to the driver’s comfort being reduced. The obtained results can be used in the design of vehicle and road bumps pavement.

  15. Raising the legal drinking age in Maine: impact on traffic accidents among young drivers.

    PubMed

    Wagenaar, A C

    1983-04-01

    The minimum legal age for purchase and consumption of alcoholic beverages continues to be a controversial issue in North America as numerous jurisdictions that lowered the legal age in the early 1970s are returning to higher drinking ages. Monthly frequencies of motor vehicle crashes among drivers aged 18-45 in the states of Maine and Pennsylvania from 1972 through 1979 were examined using a multiple time series design. Controlling for the effects of long-term trends, seasonal cycles, and other factors with Box-Jenkins time series models, a significant 17-21% reduction in alcohol-related property damage crash involvement among drivers aged 18-19 is attributable to Maine's increase in drinking age. No demonstrable effect of the raised drinking age on the incidence of injury and fatal crashes was found.

  16. Parental perceptions of teen driving: Restrictions, worry and influence.

    PubMed

    Jewett, Amy; Shults, Ruth A; Bhat, Geeta

    2016-12-01

    Parents play a critical role in preventing crashes among teens. Research of parental perceptions and concerns regarding teen driving safety is limited. We examined results from the 2013 Summer ConsumerStyles survey that queried parents about restrictions placed on their teen drivers, their perceived level of "worry" about their teen driver's safety, and influence of parental restrictions regarding their teen's driving. We produced frequency distributions for the number of restrictions imposed, parental "worry," and influence of rules regarding their teen's driving, reported by teen's driving license status (learning to drive or obtained a driver's license). Response categories were dichotomized because of small cell sizes, and we ran separate log-linear regression models to explore whether imposing all four restrictions on teen drivers was associated with either worry intensity ("a lot" versus "somewhat, not very much or not at all") or perceived influence of parental rules ("a lot" versus "somewhat, not very much or not at all"). Among the 456 parent respondents, 80% reported having restrictions for their teen driver regarding use of safety belts, drinking and driving, cell phones, and text messaging while driving. However, among the 188 parents of licensed teens, only 9% reported having a written parent-teen driving agreement, either currently or in the past. Worrying "a lot" was reported less frequently by parents of newly licensed teens (36%) compared with parents of learning teens (61%). Parents report having rules and restrictions for their teen drivers, but only a small percentage formalize the rules and restrictions in a written parent-teen driving agreement. Parents worry less about their teen driver's safety during the newly licensed phase, when crash risk is high as compared to the learning phase. Further research is needed into how to effectively support parents in supervising and monitoring their teen driver. Published by Elsevier Ltd.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickett, Lyle; Manin, Julien; Eagle, Ethan

    A Sandia National Laboratories' light emitting diode (LED) driver is generating light pulses with shorter duration higher repetition frequency and higher brightness than anything on the market. The Sandia LED Pulser uses custom electronic circuitry to drive high-power LEDs to generate short, bright, high frequency light pulses. A single device can emit up to four different colors - each with independent pulse timing - crucial for light-beam forming in many optical applications and is more economical than current light sources such as lasers.

  18. Counterfeit Electronic Parts Controls in the Department of Defense Supply Chain

    DTIC Science & Technology

    2015-06-01

    Equipment Manufacturer RFID Radio Frequency Identification SASC Senate Armed Services Committee SECDEF Secretary of Defense SWPaC Space, Weight...radio frequency identification ( RFID ). Upon the use of that printer, the RFID is checked to ensure it is a valid platform, and will not work if the... RFID is not confirmed to be valid (Richetto, 2011). Greater collaboration with industry would also help with one of the primary drivers of

  19. Mid-infrared-to-mid-ultraviolet supercontinuum enhanced by third-to-fifteenth odd harmonics.

    PubMed

    Mitrofanov, A V; Voronin, A A; Mitryukovskiy, S I; Sidorov-Biryukov, D A; Pugžlys, A; Andriukaitis, G; Flöry, T; Stepanov, E A; Fedotov, A B; Baltuška, A; Zheltikov, A M

    2015-05-01

    A high-energy supercontinuum spanning 4.7 octaves, from 250 to 6500 nm, is generated using a 0.3-TW, 3.9-μm output of a mid-infrared optical parametric chirped-pulse amplifier as a driver inducing a laser filament in the air. The high-frequency wing of the supercontinuum spectrum is enhanced by odd-order optical harmonics of the mid-infrared driver. Optical harmonics up to the 15th order are observed in supercontinuum spectra as overlapping, yet well-resolved peaks broadened, as verified by numerical modeling, due to spatially nonuniform ionization-induced blue shift.

  20. Cognitive-behavioral treatment of high anger drivers.

    PubMed

    Deffenbacher, Jerry L; Filetti, Linda B; Lynch, Rebekah S; Dahlen, Eric R; Oetting, Eugene R

    2002-08-01

    Relaxation and cognitive-relaxation interventions were compared to a no treatment control in the treatment of high anger drivers. The cognitive portion of the cognitive-relaxation condition adapted the style of Beck's cognitive therapy, particularly use of Socratic questions and behavioral experiments and tryouts, to driving anger reduction. Both interventions lowered indices of driving anger and hostile and aggressive forms of expressing driving anger and increased adaptive/constructive ways of expressing driving anger. The cognitive-relaxation intervention also lowered the frequency of risky behavior. Both interventions lowered trait anger as well. Limitations and implications for treatment and research were discussed.

  1. MR Elastography and Diffusion-Weighted Imaging of ex-vivo Prostate Cancer: quantitative comparison to histopathology

    PubMed Central

    Nir, Guy; Gagnon, Louis O.; Ischia, Joseph; Jones, Edward C.; Chang, Silvia; Yung, Andrew; Honarvar, Mohammad; Fazli, Ladan; Goldenberg, Larry; Rohling, Robert; Sinkus, Ralph; Kozlowski, Piotr

    2017-01-01

    Purpose 1) to develop a Magnetic Resonance Elastography (MRE) system for imaging of the ex-vivo human prostate, 2) to assess the diagnostic power of mono-frequency and multi-frequency MRE and diffusion weighted imaging (DWI) alone and combined as correlated with histopathology in a patient study. Materials and Methods An electromagnetic driver was designed specifically for MRE studies in small-bore MR scanners. Ex-vivo prostate specimens (post-fixation) of fourteen patients who underwent radical prostatectomy were imaged with MRE at 7 T (nine cases had DWI). In six patients, the MRE examination was performed at three frequencies (600, 800, 1000 Hz) to extract the power-law exponent Gamma. The images were registered to wholemount pathology slides marked with the Gleason score. The areas under the Receiver-Operator-Characteristic curves (AUC) were calculated. Results The methods were validated in a phantom study and demonstrated that (i) the driver does not interfere with the acquisition process, (ii) the driver can generate amplitudes greater than 100 μm for frequencies <1kHz. In the quantitative study, cancerous tissue with Gleason score at least 3+3 was distinguished from normal tissue in the peripheral zone with an average AUC of 0.75 (Gd), 0.75 (Gl), 0.70 (Gamma-Gd), 0.68 (ADC), and 0.82 (Gd+Gl+ADC). The differentiation between PZ and CG was modest for Gd (p<0.07), Gl (p<0.06) but not significant for Gamma (p<0.2). A correlation of 0.4 kPa/h was found between fixation time of the prostate specimen to the stiffness of the tissue which could affect the diagnostic power results. Conclusion DWI and MRE may provide complementary information; in fact MRE performed better than ADC in distinguishing normal from cancerous tissue in some cases. Multi-frequency (Gamma) analysis did not appear to improve the results. However, in light of effect of tissue fixation, the clinical implication of our results may be inconclusive and more experiments are needed. PMID:25382459

  2. Occupational Radiation Exposure During Endovascular Aortic Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sailer, Anna M., E-mail: anni.sailer@mumc.nl; Schurink, Geert Willem H., E-mail: gwh.schurink@mumc.nl; Bol, Martine E., E-mail: m.bol@maastrichtuniversity.nl

    PurposeThe aim of the study was to evaluate the radiation exposure to operating room personnel and to assess determinants for high personal doses during endovascular aortic repair.Materials and MethodsOccupational radiation exposure was prospectively evaluated during 22 infra-renal aortic repair procedures (EVAR), 11 thoracic aortic repair procedures (TEVAR), and 11 fenestrated or branched aortic repair procedures (FEVAR). Real-time over-lead dosimeters attached to the left breast pocket measured personal doses for the first operators (FO) and second operators (SO), radiology technicians (RT), scrub nurses (SN), anesthesiologists (AN), and non-sterile nurses (NSN). Besides protective apron and thyroid collar, no additional radiation shielding wasmore » used. Procedural dose area product (DAP), iodinated contrast volume, fluoroscopy time, patient’s body weight, and C-arm angulation were documented.ResultsAverage procedural FO dose was significantly higher during FEVAR (0.34 ± 0.28 mSv) compared to EVAR (0.11 ± 0.21 mSv) and TEVAR (0.06 ± 0.05 mSv; p = 0.003). Average personnel doses were 0.17 ± 0.21 mSv (FO), 0.042 ± 0.045 mSv (SO), 0.019 ± 0.042 mSv (RT), 0.017 ± 0.031 mSv (SN), 0.006 ± 0.007 mSv (AN), and 0.004 ± 0.009 mSv (NSN). SO and AN doses were strongly correlated with FO dose (p = 0.003 and p < 0.001). There was a significant correlation between FO dose and procedural DAP (R = 0.69, p < 0.001), iodinated contrast volume (R = 0.67, p < 0.001) and left-anterior C-arm projections >60° (p = 0.02), and a weak correlation with fluoroscopy time (R = 0.40, p = 0.049).ConclusionAverage FO dose was a factor four higher than SO dose. Predictors for high personal doses are procedural DAP, iodinated contrast volume, and left-anterior C-arm projections greater than 60°.« less

  3. A Context-Aware S-Health Service System for Drivers.

    PubMed

    Chang, Jingkun; Yao, Wenbin; Li, Xiaoyong

    2017-03-17

    As a stressful and sensitive task, driving can be disturbed by various factors from the health condition of the driver to the environmental variables of the vehicle. Continuous monitoring of driving hazards and providing the most appropriate business services to meet actual needs can guarantee safe driving and make great use of the existing information resources and business services. However, there is no in-depth research on the perception of a driver's health status or the provision of customized business services in case of various hazardous situations. In order to constantly monitor the health status of the drivers and react to abnormal situations, this paper proposes a context-aware service system providing a configurable architecture for the design and implementation of the smart health service system for safe driving, which can perceive a driver's health status and provide helpful services to the driver. With the context-aware technology to construct a smart health services system for safe driving, this is the first time that such a service system has been implemented in practice. Additionally, an assessment model is proposed to mitigate the impact of the acceptable abnormal status and, thus, reduce the unnecessary invocation of the services. With regard to different assessed situations, the business services can be invoked for the driver to adapt to hazardous situations according to the services configuration model, which can take full advantage of the existing information resources and business services. The evaluation results indicate that the alteration of the observed status in a valid time range T can be tolerated and the frequency of the service invocation can be reduced.

  4. Phone use and crashes while driving: A representative survey of drivers in two Australian states.

    PubMed

    McEvoy, Suzanne P; Stevenson, Mark R; Woodward, Mark

    To explore the use and effects of using mobile phones while driving. Cross-sectional survey. New South Wales and Western Australia, 20 October to 7 November 2003. 1347 licensed drivers aged 18 to 65 years. Data were weighted to reflect the corresponding driving population in each state. Mobile phone use while driving (hand-held, hands-free and text messaging); adverse effects of use. While driving, an estimated 57.3% +/- 1.5% of drivers have ever used a mobile phone and 12.4% +/- 1.0% have written text messages. Men, younger drivers and metropolitan residents were more likely to use a phone while driving and to report a higher frequency of use. Enforcement of hand-held phone restrictions was perceived to be low (69.0% +/- 1.5%) and an estimated 39.4% +/- 2.1% of people who phone while driving use a hand-held phone. Half of all drivers (50.1% +/- 1.6%) did not agree with extending the ban to include hands-free phones. Among drivers aged 18-65 years in NSW and WA, an estimated 45 800 +/- 16 466 (0.9% +/- 0.3%) have ever had a crash while using a mobile phone and, in the past year, 146 762 +/- 26 856 (3.0% +/- 0.6%) have had to take evasive action to avoid a crash because of their phone use. Phone use while driving is prevalent and can result in adverse consequences, including crashes. Despite legislation, a significant proportion of drivers continue to use hand-held mobile phones while driving. Enhanced enforcement is needed.

  5. Classification of a Driver's cognitive workload levels using artificial neural network on ECG signals.

    PubMed

    Tjolleng, Amir; Jung, Kihyo; Hong, Wongi; Lee, Wonsup; Lee, Baekhee; You, Heecheon; Son, Joonwoo; Park, Seikwon

    2017-03-01

    An artificial neural network (ANN) model was developed in the present study to classify the level of a driver's cognitive workload based on electrocardiography (ECG). ECG signals were measured on 15 male participants while they performed a simulated driving task as a primary task with/without an N-back task as a secondary task. Three time-domain ECG measures (mean inter-beat interval (IBI), standard deviation of IBIs, and root mean squared difference of adjacent IBIs) and three frequencydomain ECG measures (power in low frequency, power in high frequency, and ratio of power in low and high frequencies) were calculated. To compensate for individual differences in heart response during the driving tasks, a three-step data processing procedure was performed to ECG signals of each participant: (1) selection of two most sensitive ECG measures, (2) definition of three (low, medium, and high) cognitive workload levels, and (3) normalization of the selected ECG measures. An ANN model was constructed using a feed-forward network and scaled conjugate gradient as a back-propagation learning rule. The accuracy of the ANN classification model was found satisfactory for learning data (95%) and testing data (82%). Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Work schedules of long-distance truck drivers before and after 2004 hours-of-service rule change.

    PubMed

    McCartt, Anne T; Hellinga, Laurie A; Solomon, Mark G

    2008-01-01

    Federal rules regulate work hours of interstate commercial truck drivers. On January 4, 2004, a new work rule was implemented, increasing daily and weekly maximum driving limits and daily off-duty requirements. The present study assessed changes in long-distance truck drivers' reported work schedules and reported fatigued driving after the rule change. Associations between reported rule violations, fatigued driving, and schedule as well as other characteristics were examined. Samples of long-distance truck drivers were interviewed face-to-face in two states immediately before the rule change (November-December 2003) and about 1 year (November-December 2004) and 2 years (November-December 2005) after the change. Drivers reported substantially more hours of driving after the rule change. Most drivers reported regularly using a new restart provision, which permits a substantial increase in weekly driving. Reported daily off-duty and sleep time increased. Reported incidents of falling asleep at the wheel of the truck increased between 2003 (before the rule change) and 2004 and 2005 (after the change); in 2005 about one fifth of drivers reported falling asleep at the wheel in the past month. The frequency of reported rule violations under the old and new rules was similar. The percentage of trucks with electronic on-board recorders increased significantly to almost half the fleet; only a few drivers were using automated recorders to report rule compliance. More than half of drivers said that requiring automated recorders on all large trucks to enforce driving-hour limits would improve compliance with work rules. Based on the 2004-2005 survey data, drivers who reported more frequent rule violations were significantly more likely to report fatigued driving. Predictors of reported violations included having unrealistic delivery schedules, longer wait times to drop off or pick up loads, difficulty finding a legal place to stop or rest, and driving a refrigerated trailer. Reported truck driver fatigue increased after the new rule was implemented, suggesting that the rule change may not have achieved the goal of reducing fatigued driving. Reported violations of the work rules remain common. Because many trucks already have electronic recorders, requiring them as a means of monitoring driving hours appears feasible.

  7. Phase modulation in RF tag

    DOEpatents

    Carrender, Curtis Lee; Gilbert, Ronald W.

    2007-02-20

    A radio frequency (RF) communication system employs phase-modulated backscatter signals for RF communication from an RF tag to an interrogator. The interrogator transmits a continuous wave interrogation signal to the RF tag, which based on an information code stored in a memory, phase-modulates the interrogation signal to produce a backscatter response signal that is transmitted back to the interrogator. A phase modulator structure in the RF tag may include a switch coupled between an antenna and a quarter-wavelength stub; and a driver coupled between the memory and a control terminal of the switch. The driver is structured to produce a modulating signal corresponding to the information code, the modulating signal alternately opening and closing the switch to respectively decrease and increase the transmission path taken by the interrogation signal and thereby modulate the phase of the response signal. Alternatively, the phase modulator may include a diode coupled between the antenna and driver. The modulating signal from the driver modulates the capacitance of the diode, which modulates the phase of the response signal reflected by the diode and antenna.

  8. Modeling the Evolution of Female Meiotic Drive in Maize

    PubMed Central

    Hall, David W.; Dawe, R. Kelly

    2017-01-01

    Autosomal drivers violate Mendel’s law of segregation in that they are overrepresented in gametes of heterozygous parents. For drivers to be polymorphic within populations rather than fixing, their transmission advantage must be offset by deleterious effects on other fitness components. In this paper, we develop an analytical model for the evolution of autosomal drivers that is motivated by the neocentromere drive system found in maize. In particular, we model both the transmission advantage and deleterious fitness effects on seed viability, pollen viability, seed to adult survival mediated by maternal genotype, and seed to adult survival mediated by offspring genotype. We derive general, biologically intuitive conditions for the four most likely evolutionary outcomes and discuss the expected evolution of autosomal drivers given these conditions. Finally, we determine the expected equilibrium allele frequencies predicted by the model given recent estimates of fitness components for all relevant genotypes and show that the predicted equilibrium is within the range observed in maize land races for levels of drive at the low end of what has been observed. PMID:29122849

  9. A mediation model linking dispatcher leadership and work ownership with safety climate as predictors of truck driver safety performance.

    PubMed

    Zohar, Dov; Huang, Yueng-hsiang; Lee, Jin; Robertson, Michelle

    2014-01-01

    The study was designed to test the effect of safety climate on safety behavior among lone employees whose work environment promotes individual rather than consensual or shared climate perceptions. The paper presents a mediation path model linking psychological (individual-level) safety climate antecedents and consequences as predictors of driving safety of long-haul truck drivers. Climate antecedents included dispatcher (distant) leadership and driver work ownership, two contextual attributes of lone work, whereas its proximal consequence included driving safety. Using a prospective design, safety outcomes, consisting of hard-braking frequency (i.e. traffic near-miss events) were collected six months after survey completion, using GPS-based truck deceleration data. Results supported the hypothesized model, indicating that distant leadership style and work ownership promote psychological safety climate perceptions, with subsequent prediction of hard-braking events mediated by driving safety. Theoretical and practical implications for studying safety climate among lone workers in general and professional drivers in particular are discussed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Fatality rate of pedestrians and fatal crash involvement rate of drivers in pedestrian crashes: a case study of Iran.

    PubMed

    Kashani, Ali Tavakoli; Besharati, Mohammad Mehdi

    2017-06-01

    The aim of this study was to uncover patterns of pedestrian crashes. In the first stage, 34,178 pedestrian-involved crashes occurred in Iran during a four-year period were grouped into homogeneous clusters using a clustering analysis. Next, some in-cluster and inter-cluster crash patterns were analysed. The clustering analysis yielded six pedestrian crash groups. Car/van/pickup crashes on rural roads as well as heavy vehicle crashes were found to be less frequent but more likely to be fatal compared to other crash clusters. In addition, after controlling for crash frequency in each cluster, it was found that the fatality rate of each pedestrian age group as well as the fatal crash involvement rate of each driver age group varies across the six clusters. Results of present study has some policy implications including, promoting pedestrian safety training sessions for heavy vehicle drivers, imposing limitations over elderly heavy vehicle drivers, reinforcing penalties toward under 19 drivers and motorcyclists. In addition, road safety campaigns in rural areas may be promoted to inform people about the higher fatality rate of pedestrians on rural roads. The crash patterns uncovered in this study might also be useful for prioritizing future pedestrian safety research areas.

  11. Design of a 16 gray scales 320 × 240 pixels OLED-on-silicon driving circuit

    NASA Astrophysics Data System (ADS)

    Ran, Huang; Xiaohui, Wang; Wenbo, Wang; Huan, Du; Zhengsheng, Han

    2009-01-01

    A 320×240 pixel organic-light-emitting-diode-on-silicon (OLEDoS) driving circuit is implemented using the standard 0.5 μm CMOS process of CSMC. It gives 16 gray scales with integrated 4 bit D/A converters. A three-transistor voltage-programmed OLED pixel driver is proposed, which can realize the very small current driving required for the OLEDoS microdisplay. Both the D/A converter and the pixel driver are implemented with pMOS devices. The pass-transistor and capacitance in the OLED pixel driver can be used to sample the output of the D/A converter. An additional pMOS is added to OLED pixel driver, which is used to control the D/A converter operating only when one row is on. This can reduce the circuit's power consumption. This driving circuit can work properly in a frame frequency of 50 Hz, and the final layout of this circuit is given. The pixel area is 28.4 × 28.4 μm2 and the display area is 10.7 × 8.0 mm2 (the diagonal is about 13 mm). The measured pixel gray scale voltage shows that the function of the driver circuit is correct, and the power consumption of the chip is about 350 mW.

  12. Research on Crowdsourcing Emergency Information Extraction of Based on Events' Frame

    NASA Astrophysics Data System (ADS)

    Yang, Bo; Wang, Jizhou; Ma, Weijun; Mao, Xi

    2018-01-01

    At present, the common information extraction method cannot extract the structured emergency event information accurately; the general information retrieval tool cannot completely identify the emergency geographic information; these ways also do not have an accurate assessment of these results of distilling. So, this paper proposes an emergency information collection technology based on event framework. This technique is to solve the problem of emergency information picking. It mainly includes emergency information extraction model (EIEM), complete address recognition method (CARM) and the accuracy evaluation model of emergency information (AEMEI). EIEM can be structured to extract emergency information and complements the lack of network data acquisition in emergency mapping. CARM uses a hierarchical model and the shortest path algorithm and allows the toponomy pieces to be joined as a full address. AEMEI analyzes the results of the emergency event and summarizes the advantages and disadvantages of the event framework. Experiments show that event frame technology can solve the problem of emergency information drawing and provides reference cases for other applications. When the emergency disaster is about to occur, the relevant departments query emergency's data that has occurred in the past. They can make arrangements ahead of schedule which defense and reducing disaster. The technology decreases the number of casualties and property damage in the country and world. This is of great significance to the state and society.

  13. In vitro and in vivo evaluation of the antioxidant and prooxidant activity of phenolic compounds obtained from grape (Vitis vinifera) pomace.

    PubMed

    Cotoras, Milena; Vivanco, Herman; Melo, Ricardo; Aguirre, María; Silva, Evelyn; Mendoza, Leonora

    2014-12-16

    The antioxidant and/or prooxidant ability of extracts obtained from wine waste were analyzed using in vitro and in vivo assays. Cyclic voltammetry was used as the in vitro assay to determine the antioxidant and/or prooxidant properties and, the in vivo effect on mycelial growth of the fungus Botrytis cinerea was evaluated. In addition, the prooxidant activity was evaluated by intracellular oxidation of compound 2,7-dichlorodihydrofluorescein diacetate (DCFH-DA) in B. cinerea. The extracts used in this study were obtained from grape pomace of Cabernet Sauvignon, Carménère and Syrah varieties from the Misiones de Rengo Vineyard by simple extraction, using methanol/HCl 1% (v/v), ethanol 70% (v/v), or Soxhlet extraction. According to the results obtained, gallic acid was the most represented phenolic compound independent of grape variety and extraction method. In addition, vanillic acid; protocatechuic acid, syringic acid, quercetin and kaempferol were found in the extracts. From this study it was possible concluded that, depending of the method of extraction of the grape residues and the grape variety (Cabernet Sauvignon, Carménère and Syrah), the extracts showed antioxidant and/or prooxidant activity. However, no correlation can be established between the anodic oxidation potentials of the extracts and their effect on the fungus B. cinerea.

  14. Arginine (Di)methylated Human Leukocyte Antigen Class I Peptides Are Favorably Presented by HLA-B*07.

    PubMed

    Marino, Fabio; Mommen, Geert P M; Jeko, Anita; Meiring, Hugo D; van Gaans-van den Brink, Jacqueline A M; Scheltema, Richard A; van Els, Cécile A C M; Heck, Albert J R

    2017-01-06

    Alterations in protein post-translational modification (PTM) are recognized hallmarks of diseases. These modifications potentially provide a unique source of disease-related human leukocyte antigen (HLA) class I-presented peptides that can elicit specific immune responses. While phosphorylated HLA peptides have already received attention, arginine methylated HLA class I peptide presentation has not been characterized in detail. In a human B-cell line we detected 149 HLA class I peptides harboring mono- and/or dimethylated arginine residues by mass spectrometry. A striking preference was observed in the presentation of arginine (di)methylated peptides for HLA-B*07 molecules, likely because the binding motifs of this allele resemble consensus sequences recognized by arginine methyl-transferases. Moreover, HLA-B*07-bound peptides preferentially harbored dimethylated groups at the P3 position, thus consecutively to the proline anchor residue. Such a proline-arginine sequence has been associated with the arginine methyl-transferases CARM1 and PRMT5. Making use of the specific neutral losses in fragmentation spectra, we found most of the peptides to be asymmetrically dimethylated, most likely by CARM1. These data expand our knowledge of the processing and presentation of arginine (di)methylated HLA class I peptides and demonstrate that these types of modified peptides can be presented for recognition by T-cells. HLA class I peptides with mono- and dimethylated arginine residues may therefore offer a novel target for immunotherapy.

  15. Radiation exposure and safety practices during pediatric central line placement

    PubMed Central

    Saeman, Melody R.; Burkhalter, Lorrie S.; Blackburn, Timothy J.; Murphy, Joseph T.

    2015-01-01

    Purpose Pediatric surgeons routinely use fluoroscopy for central venous line (CVL) placement. We examined radiation safety practices and patient/surgeon exposure during fluoroscopic CVL. Methods Fluoroscopic CVL procedures performed by 11 pediatric surgeons in 2012 were reviewed. Fluoroscopic time (FT), patient exposure (mGy), and procedural data were collected. Anthropomorphic phantom simulations were used to calculate scatter and dose (mSv). Surgeons were surveyed regarding safety practices. Results 386 procedures were reviewed. Median FT was 12.8 seconds. Median patient estimated effective dose was 0.13 mSv. Median annual FT per surgeon was 15.4 minutes. Simulations showed no significant difference (p = 0.14) between reported exposures (median 3.5 mGy/min) and the modeled regression exposures from the C-arm default mode (median 3.4 mGy/min). Median calculated surgeon exposure was 1.5 mGy/year. Eight of 11 surgeons responded to the survey. Only three reported 100% lead protection and frequent dosimeter use. Conclusion We found non-standard radiation training, safety practices, and dose monitoring for the 11 surgeons. Based on simulations, the C-arm default setting was typically used instead of low dose. While most CVL procedures have low patient/surgeon doses, every effort should be used to minimize patient and occupational exposure, suggesting the need for formal hands-on training for non-radiologist providers using fluoroscopy. PMID:25837269

  16. Automatic 3D reconstruction of electrophysiology catheters from two-view monoplane C-arm image sequences.

    PubMed

    Baur, Christoph; Milletari, Fausto; Belagiannis, Vasileios; Navab, Nassir; Fallavollita, Pascal

    2016-07-01

    Catheter guidance is a vital task for the success of electrophysiology interventions. It is usually provided through fluoroscopic images that are taken intra-operatively. The cardiologists, who are typically equipped with C-arm systems, scan the patient from multiple views rotating the fluoroscope around one of its axes. The resulting sequences allow the cardiologists to build a mental model of the 3D position of the catheters and interest points from the multiple views. We describe and compare different 3D catheter reconstruction strategies and ultimately propose a novel and robust method for the automatic reconstruction of 3D catheters in non-synchronized fluoroscopic sequences. This approach does not purely rely on triangulation but incorporates prior knowledge about the catheters. In conjunction with an automatic detection method, we demonstrate the performance of our method compared to ground truth annotations. In our experiments that include 20 biplane datasets, we achieve an average reprojection error of 0.43 mm and an average reconstruction error of 0.67 mm compared to gold standard annotation. In clinical practice, catheters suffer from complex motion due to the combined effect of heartbeat and respiratory motion. As a result, any 3D reconstruction algorithm via triangulation is imprecise. We have proposed a new method that is fully automatic and highly accurate to reconstruct catheters in three dimensions.

  17. An iterative algorithm for soft tissue reconstruction from truncated flat panel projections

    NASA Astrophysics Data System (ADS)

    Langan, D.; Claus, B.; Edic, P.; Vaillant, R.; De Man, B.; Basu, S.; Iatrou, M.

    2006-03-01

    The capabilities of flat panel interventional x-ray systems continue to expand, enabling a broader array of medical applications to be performed in a minimally invasive manner. Although CT is providing pre-operative 3D information, there is a need for 3D imaging of low contrast soft tissue during interventions in a number of areas including neurology, cardiac electro-physiology, and oncology. Unlike CT systems, interventional angiographic x-ray systems provide real-time large field of view 2D imaging, patient access, and flexible gantry positioning enabling interventional procedures. However, relative to CT, these C-arm flat panel systems have additional technical challenges in 3D soft tissue imaging including slower rotation speed, gantry vibration, reduced lateral patient field of view (FOV), and increased scatter. The reduced patient FOV often results in significant data truncation. Reconstruction of truncated (incomplete) data is known an "interior problem", and it is mathematically impossible to obtain an exact reconstruction. Nevertheless, it is an important problem in 3D imaging on a C-arm to address the need to generate a 3D reconstruction representative of the object being imaged with minimal artifacts. In this work we investigate the application of an iterative Maximum Likelihood Transmission (MLTR) algorithm to truncated data. We also consider truncated data with limited views for cardiac imaging where the views are gated by the electrocardiogram(ECG) to combat motion artifacts.

  18. Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment.

    PubMed

    Enomoto, Yukiko; Yamauchi, Keita; Asano, Takahiko; Otani, Katharina; Iwama, Toru

    2018-01-01

    Background and purpose C-arm cone-beam computed tomography (CBCT) has the drawback that image quality is degraded by artifacts caused by implanted metal objects. We evaluated whether metal artifact reduction (MAR) prototype software can improve the subjective image quality of CBCT images of patients with intracranial aneurysms treated with coils or clips. Materials and methods Forty-four patients with intracranial aneurysms implanted with coils (40 patients) or clips (four patients) underwent one CBCT scan from which uncorrected and MAR-corrected CBCT image datasets were reconstructed. Three blinded readers evaluated the image quality of the image sets using a four-point scale (1: Excellent, 2: Good, 3: Poor, 4: Bad). The median scores of the three readers of uncorrected and MAR-corrected images were compared with the paired Wilcoxon signed-rank and inter-reader agreement of change scores was assessed by weighted kappa statistics. The readers also recorded new clinical findings, such as intracranial hemorrhage, air, or surrounding anatomical structures on MAR-corrected images. Results The image quality of MAR-corrected CBCT images was significantly improved compared with the uncorrected CBCT image ( p < 0.001). Additional clinical findings were seen on CBCT images of 70.4% of patients after MAR correction. Conclusion MAR software improved image quality of CBCT images degraded by metal artifacts.

  19. Dual-projection 3D-2D registration for surgical guidance: preclinical evaluation of performance and minimum angular separation

    NASA Astrophysics Data System (ADS)

    Uneri, A.; Otake, Y.; Wang, A. S.; Kleinszig, G.; Vogt, S.; Gallia, G. L.; Rigamonti, D.; Wolinsky, J.-P.; Gokaslan, Ziya L.; Khanna, A. J.; Siewerdsen, J. H.

    2014-03-01

    An algorithm for 3D-2D registration of CT and x-ray projections has been developed using dual projection views to provide 3D localization with accuracy exceeding that of conventional tracking systems. The registration framework employs a normalized gradient information (NGI) similarity metric and covariance matrix adaptation evolution strategy (CMAES) to solve for the patient pose in 6 degrees of freedom. Registration performance was evaluated in anthropomorphic head and chest phantoms, as well as a human torso cadaver, using C-arm projection views acquired at angular separations (Δ𝜃) ranging 0-178°. Registration accuracy was assessed in terms target registration error (TRE) and compared to that of an electromagnetic tracker. Studies evaluated the influence of C-arm magnification, x-ray dose, and preoperative CT slice thickness on registration accuracy and the minimum angular separation required to achieve TRE ~2 mm. The results indicate that Δ𝜃 as small as 10-20° is adequate to achieve TRE <2 mm with 95% confidence, comparable or superior to that of commercial trackers. The method allows direct registration of preoperative CT and planning data to intraoperative fluoroscopy, providing 3D localization free from conventional limitations associated with external fiducial markers, stereotactic frames, trackers, and manual registration. The studies support potential application to percutaneous spine procedures and intracranial neurosurgery.

  20. The frequency--severity indeterminacy.

    PubMed

    Hauer, Ezra

    2006-01-01

    Nothing is known about unreported crashes; the information we have is of reported crashes only. Whether a crash gets reported depends on its severity. It follows by logic that, using only data about reported crashes, it is impossible to say whether a change or difference in crash counts reflects a change or difference in crash frequency or in crash severity. This indeterminacy has practical implications. Examples discussed are of the misattribution of over-representation in reported crashes of older drivers and of trucks to causal factors related to the frequency of crash involvement, and of misinterpretation by researchers of findings about the rollover propensity of SUVs.

  1. Association between travel length and drug use among Brazilian truck drivers.

    PubMed

    Sinagawa, Daniele Mayumi; De Carvalho, Heráclito Barbosa; Andreuccetti, Gabriel; Do Prado, Natanael Vitoriano; De Oliveira, Keziah Cristina Barbosa Gruber; Yonamine, Mauricio; Muñoz, Daniel Romero; Gjerde, Hallvard; Leyton, Vilma

    2015-01-01

    To investigate whether the use of the stimulants amphetamines and cocaine by truck drivers in Brazil was related to travel length. Truck drivers were randomly stopped by the Federal Highway Police on interstate roads in Sao Paulo State during morning hours from 2008 to 2011 and invited to participate in the project "Comandos de Saúde nas Rodovias" (Health Commands on the Roads). Participants were asked about the use of drugs, travel distance, and age, and gender was recorded. Samples of urine were collected and analyzed for amphetamine, benzoylecgonine (a metabolite of cocaine), and carboxytetrahydrocannabinol (THC-COOH; a metabolite of cannabis) by immunological screening and quantification by gas chromatography-mass spectroscopy. Current use of amphetamine, cocaine, and cannabis was reported by 5.7%, 0.7%, and 0.3% of the truck drivers, respectively. Amphetamine, benzoylecgonine, and THC-COOH were found in urine samples from 5.4%, 2.6,% and in 1.0% of the drivers, respectively. There was a significant association between the positive cases for amphetamine and reported travel length; 9.9% of urine samples from drivers who reported travel length of more than 270 km were positive for amphetamine, and 10.9% of those drivers reported current use of amphetamines. In most cases, appetite suppressants containing amphetamines had been used, but the purpose was most often to stay awake and alert while driving. Truck drivers with travel length of more than 270 km had significantly higher odds ratio (OR) for having a urine sample that was positive for amphetamine when adjusted for age as confounding factor (OR = 9.41, 95% confidence interval [CI], 3.97-22.26). No significant association was found between the use of cocaine or cannabis and travel length. Truck drivers who reported driving more than 270 km had significantly higher frequencies of urine samples positive for amphetamine and reported significantly more frequent current use of amphetamines than those who reported shorter driving distances.

  2. Taxi driver speeding: Who, when, where and how? A comparative study between Shanghai and New York City.

    PubMed

    Huang, Yizhe; Sun, Daniel Jian; Tang, Juanyu

    2018-04-03

    The 3 objectives of this study are to (1) identify the driving style characteristics of taxi drivers in Shanghai and New York City (NYC) using taxi Global Positioning System (GPS) data and make a comparative analysis; (2) explore the influence of different driving style characteristics on the frequency of speeding (who and how?) and (3) explore the influence of driving style characteristics, road attributes, and environmental factors on the speeding rate (when, where, and how?) Methods: This study proposes a driver-road-environment identification (DREI) method to investigate the determinant factors of taxi speeding violations. Driving style characteristics, together with road and environment variables, were obtained based on the GPS data and auxiliary spatiotemporal data in Shanghai and NYC. The daily working hours of taxi drivers in Shanghai (18.6 h) was far more than in NYC (8.5 h). The average occupancy speed of taxi drivers in Shanghai (21.3 km/h) was similar to that of NYC (20.3 km/h). Speeders in both cities had shorter working hours and longer daily driving distance than other taxi drivers, though their daily income was similar. Speeding drivers routinely took long-distance trips (>10 km) and preferred relatively faster routes. Length of segments (1.0-1.5 km) and good traffic condition were associated with high speeding rates, whereas central business district area and secondary road were associated with low speeding rates. Moreover, many speeding violations were identified between 4:00 a.m. and 7:00 a.m. in both Shanghai and NYC and the worst period was between 5:00 a.m. and 6:00 a.m. in both cities. Characteristics of drivers, road attributes, and environment variables should be considered together when studying driver speeding behavior. Findings of this study may assist in stipulating relevant laws and regulations such as stricter offense monitoring in the early morning, long segment supervision, shift rule regulation, and working hour restriction to mitigate the risk of potential crashes.

  3. Association of heart rate variability in taxi drivers with marked changes in particulate air pollution in Beijing in 2008.

    PubMed

    Wu, Shaowei; Deng, Furong; Niu, Jie; Huang, Qinsheng; Liu, Youcheng; Guo, Xinbiao

    2010-01-01

    Heart rate variability (HRV), a marker of cardiac autonomic function, has been -associated with particulate matter (PM) air pollution, especially in older patients and those with cardio-vascular diseases. However, the effect of PM exposure on cardiac autonomic function in young, healthy adults has received less attention. We evaluated the relationship between exposure to traffic-related PM with an aerodynamic diameter

  4. Diabetic Driving Studies-Part 1: Brake Response Time in Diabetic Drivers With Lower Extremity Neuropathy.

    PubMed

    Meyr, Andrew J; Spiess, Kerianne E

    Although the effect of lower extremity pathology and surgical intervention on automobile driving function has been a topic of contemporary interest, we are unaware of any analysis of the effect of lower extremity diabetic sensorimotor neuropathy on driving performance. The objective of the present case-control investigation was to assess the mean brake response time in diabetic drivers with lower extremity neuropathy compared with that of a control group and a brake response safety threshold. The driving performances of participants were evaluated using a computerized driving simulator with specific measurement of the mean brake response time and frequency of abnormally delayed brake responses. We analyzed a control group of 25 active drivers with neither diabetes nor lower extremity neuropathy and an experimental group of 25 active drivers with type 2 diabetes and lower extremity neuropathy. The experimental group demonstrated a 37.89% slower mean brake response time (0.757 ± 0.180 versus 0.549 ± 0.076 second; p < .001), with abnormally delayed responses occurring at a greater frequency (57.5% versus 3.5%; p < .001). Independent of a comparative statistical analysis, the observed mean brake response time in the experimental group was slower than the reported safety brake response threshold of 0.70 second. The results of the present investigation provide original data with respect to abnormally delayed brake responses in diabetic patients with lower extremity neuropathy and might raise the potential for impaired driving function in this population. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Development of compact rapid charging power supply for capacitive energy storage in pulsed power drivers.

    PubMed

    Sharma, Surender Kumar; Shyam, Anurag

    2015-02-01

    High energy capacitor bank is used for primary electrical energy storage in pulsed power drivers. The capacitors used in these pulsed power drivers have low inductance, low internal resistance, and less dc life, so it has to be charged rapidly and immediately discharged into the load. A series resonant converter based 45 kV compact power supply is designed and developed for rapid charging of the capacitor bank with constant charging current up to 150 mA. It is short circuit proof, and zero current switching technique is used to commute the semiconductor switch. A high frequency resonant inverter switching at 10 kHz makes the overall size small and reduces the switching losses. The output current of the power supply is limited by constant on-time and variable frequency switching control technique. The power supply is tested by charging the 45 kV/1.67 μF and 15 kV/356 μF capacitor banks. It has charged the capacitor bank up to rated voltage with maximum charging current of 150 mA and the average charging rate of 3.4 kJ/s. The output current of the power supply is limited by reducing the switching frequency at 5 kHz, 3.3 kHz, and 1.7 kHz and tested with 45 kV/1.67 μF capacitor bank. The protection circuit is included in the power supply for over current, under voltage, and over temperature. The design details and the experimental testing results of the power supply for resonant current, output current, and voltage traces of the power supply with capacitive, resistive, and short circuited load are presented and discussed.

  6. High-frequency ac power distribution in Space Station

    NASA Technical Reports Server (NTRS)

    Tsai, Fu-Sheng; Lee, Fred C. Y.

    1990-01-01

    A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

  7. "Driverless" Shocks in the Interplanetary Medium

    NASA Technical Reports Server (NTRS)

    Gopalswamy, N.; Kaiser, M. L.; Lara, A.

    1999-01-01

    Many interplanetary shocks have been detected without an obvious driver behind them. These shocks have been thought to be either blast waves from solar flares or shocks due to sudden increase in solar wind speed caused by interactions between large scale open and closed field lines of the Sun. We investigated this problem using a set of interplanetary shock detected {\\it in situ} by the Wind space craft and tracing their solar origins using low frequency radio data obtained by the Wind/WAVES experiment. For each of these "driverless shocks" we could find a unique coronal mass ejections (CME) event observed by the SOHO (Solar and Heliospheric Observatory) coronagraphs. We also found that these CMEs were ejected at large angles from the Sun-Earth line. It appears that the "driverless shocks" are actually driver shocks, but the drivers were not intercepted by the spacecraft. We conclude that the interplanetary shocks are much more extended than the driving CMEs.

  8. Activated RET and ROS: two new driver mutations in lung adenocarcinoma

    PubMed Central

    Bos, Marc; Gardizi, Masyar; Schildhaus, Hans-Ulrich; Buettner, Reinhard

    2013-01-01

    Rearrangements of ROS1 and RET have been recently described as new driver mutations in lung adenocarcinoma with a frequency of about 1% each. RET and ROS1 rearrangements both represent unique molecular subsets of lung adenocarcinoma with virtually no overlap with other known driver mutations described so far in lung adenocarcinoma. Specific clinicopathologic characteristics have been described and several multitargeted receptor kinase inhibitors have shown in vitro activity against NSCLC cells harbouring these genetic alterations. In addition, the MET/ALK/ROS inhibitor crizotinib has already shown impressive clinical activity in patients with advanced ROS1-positive lung cancer. Currently, several early proof of concept clinical trials are testing various kinase inhibitors in both molecular subsets of lung adenocarcinoma patients. Most probably, personalized treatment of these genetically defined new subsets of lung adenocarcinoma will be implemented in routine clinical care of lung cancer patients in the near future. PMID:25806222

  9. Evaluating the effectiveness of Behavior-Based Safety education methods for commercial vehicle drivers.

    PubMed

    Wang, Xuesong; Xing, Yilun; Luo, Lian; Yu, Rongjie

    2018-08-01

    Risky driving behavior is one of the main causes of commercial vehicle related crashes. In order to achieve safer vehicle operation, safety education for drivers is often provided. However, the education programs vary in quality and may not always be successful in reducing crash rates. Behavior-Based Safety (BBS) education is a popular approach found effective by numerous studies, but even this approach varies as to the combination of frequency, mode and content used by different education providers. This study therefore evaluates and compares the effectiveness of BBS education methods. Thirty-five drivers in Shanghai, China, were coached with one of three different BBS education methods for 13 weeks following a 13-week baseline phase with no education. A random-effects negative binomial (NB) model was built and calibrated to investigate the relationship between BBS education and the driver at-fault safety-related event rate. Based on the results of the random-effects NB model, event modification factors (EMF) were calculated to evaluate and compare the effectiveness of the methods. Results show that (1) BBS education was confirmed to be effective in safety-related event reduction; (2) the most effective method among the three applied monthly face-to-face coaching, including feedback with video and statistical data, and training on strategies to avoid driver-specific unsafe behaviors; (3) weekly telephone coaching using statistics and strategies was rated by drivers as the most convenient delivery mode, and was also significantly effective. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Motorist Comprehension of Florida's School Bus Stop Law and School Bus Signalization Devices

    DOT National Transportation Integrated Search

    1997-06-01

    In May 1995, the Center for Urban Transportation Research (CUTR) conducted a study on behalf of the Florida Department of Education (DOE) that investigated the frequency and extent with which drivers in Florida were illegally passing stopped school b...

  11. Vehicle infrastructure integration (VII) : exploring the application of disruptive technology to assist older drivers.

    DOT National Transportation Integrated Search

    2012-01-01

    This report discusses the approach and findings of a research project aimed at the evaluation of : an inter-vehicle communications scheme for Vehicular Ad hoc Networks (VANETs). : Because of the size, frequency, and expected number of receivers of pe...

  12. Sensors in the Stream: The High-Frequency Wave of the Present.

    PubMed

    Rode, Michael; Wade, Andrew J; Cohen, Matthew J; Hensley, Robert T; Bowes, Michael J; Kirchner, James W; Arhonditsis, George B; Jordan, Phil; Kronvang, Brian; Halliday, Sarah J; Skeffington, Richard A; Rozemeijer, Joachim C; Aubert, Alice H; Rinke, Karsten; Jomaa, Seifeddine

    2016-10-04

    New scientific understanding is catalyzed by novel technologies that enhance measurement precision, resolution or type, and that provide new tools to test and develop theory. Over the last 50 years, technology has transformed the hydrologic sciences by enabling direct measurements of watershed fluxes (evapotranspiration, streamflow) at time scales and spatial extents aligned with variation in physical drivers. High frequency water quality measurements, increasingly obtained by in situ water quality sensors, are extending that transformation. Widely available sensors for some physical (temperature) and chemical (conductivity, dissolved oxygen) attributes have become integral to aquatic science, and emerging sensors for nutrients, dissolved CO 2 , turbidity, algal pigments, and dissolved organic matter are now enabling observations of watersheds and streams at time scales commensurate with their fundamental hydrological, energetic, elemental, and biological drivers. Here we synthesize insights from emerging technologies across a suite of applications, and envision future advances, enabled by sensors, in our ability to understand, predict, and restore watershed and stream systems.

  13. Psychoactive substances in seriously injured drivers in Denmark.

    PubMed

    Wiese Simonsen, K; Steentoft, A; Bernhoft, I M; Hels, T; Rasmussen, B S; Linnet, K

    2013-01-10

    This study assesses the presence of a number of psychoactive substances, including alcohol, based on blood samples from 840 seriously injured drivers admitted to five selected hospitals located in five different regions of Denmark. The study was a part of the EU 6th framework program DRUID (Driving Under the Influence of Drugs, Alcohol and Medicines). Blood samples were screened for 30 illegal and legal psychoactive substances and metabolites as well as ethanol. Danish legal limits were used to evaluate the frequency of drivers violating the Danish legislation while limit of quantification (LOQ) was used for monitoring positive drivers. Tramadol is not included in the Danish legislation therefore the general cut off, as decided in the DRUID project was used. Overall, ethanol (18%) was the most frequently identified compound (alone or in combination with other drugs) exceeding the legal limit, which is 0.53g/l in Denmark. The percentage of seriously injured drivers testing positive for medicinal drugs at levels above the Danish legal limit was 6.8%. Benzodiazepines and Z-drugs (6.4%) comprised the majority of this group. One or more illegal drugs (primarily amphetamines and cannabis) were found to be above the Danish legal limit in 4.9% of injured drivers. Young men (median age 31 years) were over-represented among injured drivers who violated Danish law for alcohol and drugs. Diazepam (4.4%), tramadol (3.2%), and clonazepam (3.0%) were the medicinal drugs most frequently detected at levels above LOQ, whereas amphetamines (5.4%) (amphetamine [5.2%] and methamphetamine [1.5%]), tetrahydrocannabinol (3.7%), and cocaine (3.3%), including the metabolite benzoylecgonine, were the most frequently detected illegal drugs. A driver could be positive for more than one substance; therefore, percentages are not mutually exclusive. Poly-drug use was observed in 112 (13%) seriously injured drivers. Tramadol was detected above DRUID cutoffs in 2.1% of seriously injured drivers. This is 3.5 times that observed in a Danish survey of randomly selected drivers. Moreover, illegal and medicinal drug levels above the Danish legal limit were present more than 10 times as frequently as in injured drivers, whereas ethanol was present more than 30 times as frequently than in randomly selected drivers. The results indicate that there is an increased risk in traffic when driving under the influence of psychoactive drugs, especially alcohol in young male drivers. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Leukaemia, brain tumours and exposure to extremely low frequency magnetic fields: cohort study of Swiss railway employees

    PubMed Central

    Röösli, Martin; Lörtscher, Manfred; Egger, Matthias; Pfluger, Dominik; Schreier, Nadja; Lörtscher, Emanuel; Locher, Peter; Spoerri, Adrian; Minder, Christoph

    2007-01-01

    Aims To investigate the relationship between extremely low frequency magnetic field (ELF‐MF) exposure and mortality from leukaemia and brain tumour in a cohort of Swiss railway workers. Methods 20 141 Swiss railway employees with 464 129 person‐years of follow‐up between 1972 and 2002 were studied. Mortality rates for leukaemia and brain tumour of highly exposed train drivers (21 μT average annual exposure) were compared with medium and low exposed occupational groups (i.e. station masters with an average exposure of 1 μT). In addition, individual cumulative exposure was calculated from on‐site measurements and modelling of past exposures. Results The hazard ratio (HR) for leukaemia mortality of train drivers was 1.43 (95% CI 0.74 to 2.77) compared with station masters. For myeloid leukaemia the HR of train drivers was 4.74 (95% CI 1.04 to 21.60) and for Hodgkin's disease 3.29 (95% CI 0.69 to 15.63). Lymphoid leukaemia, non‐Hodgkin's disease and brain tumour mortality were not associated with magnetic field exposure. Concordant results were obtained from analyses based on individual cumulative exposure. Conclusions Some evidence of an exposure–response association was found for myeloid leukaemia and Hodgkin's disease, but not for other haematopoietic and lymphatic malignancies and brain tumours. PMID:17525094

  15. High Power Microwave Tubes: Basics and Trends, Volume 2

    NASA Astrophysics Data System (ADS)

    Kesari, Vishal; Basu, B. N.

    2018-01-01

    Volume 2 of the book begins with chapter 6, in which we have taken up conventional MWTs (such as TWTs, klystrons, including multi-cavity and multi-beam klystrons, klystron variants including reflex klystron, IOT, EIK, EIO and twystron, and crossed-field tubes, namely, magnetron, CFA and carcinotron). In chapter 7, we have taken up fast-wave tubes (such as gyrotron, gyro-BWO, gyro-klystron, gyro-TWT, CARM, SWCA, hybrid gyro-tubes and peniotron). In chapter 8, we discuss vacuum microelectronic tubes (such as klystrino module, THz gyrotron and clinotron BWO); plasma-assisted tubes (such as PWT, plasma-filled TWT, BWO, including PASOTRON, and gyrotron); and HPM (high power microwave) tubes (such as relativistic TWT, relativistic BWO, RELTRON (variant of relativistic klystron), relativistic magnetron, high power Cerenkov tubes including SWO, RDG or orotron, MWCG and MWDG, bremsstrahlung radiation type tube, namely, vircator, and M-type tube MILO). In Chapter 9, we provide handy information about the frequency and power ranges of common MWTs, although more such information is provided at relevant places in the rest of the book as and where necessary. Chapter 10 is an epilogue that sums up the authors' attempt to bring out the various aspects of the basics of and trends in high power MWTs.

  16. A novel 3D-printed mechanical actuator using centrifugal force for magnetic resonance elastography.

    PubMed

    Neumann, Wiebke; Schad, Lothar R; Zollner, Frank G

    2017-07-01

    Magnetic resonance elastography (MRE) is a technique for the quantification of tissue stiffness during MR examinations. It requires consistent methods for mechanical shear wave induction to the region of interest in the human body to reliably quantify elastic properties of soft tissues. This work proposes a novel 3D-printed mechanical actuator using the principle of centrifugal force for wave induction. The driver consists of a 3D-printed turbine vibrator powered by compressed air (located inside the scanner room) and an active driver controlling the pressure of inflowing air (placed outside the scanner room). The generated force of the proposed actuator increases for higher actuation frequencies as opposed to conventionally used air cushions. There, the displacement amplitude decreases with increasing actuation frequency resulting in a smaller signal-to-noise ratio. An initial phantom study is presented which demonstrates the feasibility of the actuator for MRE. The wave-actuation frequency was regulated in a range between 15 Hz and 60 Hz for force measurements and proved sufficiently stable (± 0.3 Hz) for any given nominal frequency. The generated forces depend on the weight of the eccentric unbalance within the turbine and ranged between 0.67 N to 2.70 N (for 15 Hz) and 3.09 N to 7.77 N (for 60 Hz). Therefore, the generated force of the presented actuator increases with rotational speed of the turbine and offers an elegant solution for sufficiently large wave actuation at higher frequencies. In future work, we will investigate an optimal ratio of the weight of unbalance to the size of turbine for appropriately large but tolerable wave actuation for a given nominal frequency.

  17. Linear beam raster magnet driver based on H-bridge technique

    DOEpatents

    Sinkine, Nikolai I.; Yan, Chen; Apeldoorn, Cornelis; Dail, Jeffrey Glenn; Wojcik, Randolph Frank; Gunning, William

    2006-06-06

    An improved raster magnet driver for a linear particle beam is based on an H-bridge technique. Four branches of power HEXFETs form a two-by-two switch. Switching the HEXFETs in a predetermined order and at the right frequency produces a triangular current waveform. An H-bridge controller controls switching sequence and timing. The magnetic field of the coil follows the shape of the waveform and thus steers the beam using a triangular rather than a sinusoidal waveform. The system produces a raster pattern having a highly uniform raster density distribution, eliminates target heating from non-uniform raster density distributions, and produces higher levels of beam current.

  18. Canadian drivers' attitudes regarding preventative responses to driving while impaired by alcohol.

    PubMed

    Vanlaar, Ward; Nadeau, Louise; McKiernan, Anna; Hing, Marisela M; Ouimet, Marie Claude; Brown, Thomas G

    2017-09-01

    In many jurisdictions, a risk assessment following a first driving while impaired (DWI) offence is used to guide administrative decision making regarding driver relicensing. Decision error in this process has important consequences for public security on one hand, and the social and economic well being of drivers on the other. Decision theory posits that consideration of the costs and benefits of decision error is needed, and in the public health context, this should include community attitudes. The objective of the present study was to clarify whether Canadians prefer decision error that: i) better protects the public (i.e., false positives); or ii) better protects the offender (i.e., false negatives). A random sample of male and female adult drivers (N=1213) from the five most populated regions of Canada was surveyed on drivers' preference for a protection of the public approach versus a protection of DWI drivers approach in resolving assessment decision error, and the relative value (i.e., value ratio) they imparted to both approaches. The role of region, sex and age on drivers' value ratio were also appraised. Seventy percent of Canadian drivers preferred a protection of the public from DWI approach, with the overall relative ratio given to this preference, compared to the alternative protection of the driver approach, being 3:1. Females expressed a significantly higher value ratio (M=3.4, SD=3.5) than males (M=3.0, SD=3.4), p<0.05. Regression analysis showed that both days of alcohol use in the past 30days (CI for B: -0.07, -0.02) and frequency of driving over legal BAC limits in the past year (CI for B=-0.19, -0.01) were significantly but modestly related to lower value ratios, R 2 (adj.)=0.014, p<0.001. Regional differences were also detected. Canadian drivers strongly favour a protection of the public approach to dealing with uncertainty in assessment, even at the risk of false positives. Accounting for community attitudes concerning DWI prevention and the individual differences that influence them could contribute to more informed, coherent and effective regional policies and prevention program development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. The effect of three low-cost engineering treatments on driver fatigue: A driving simulator study.

    PubMed

    Merat, Natasha; Jamson, A Hamish

    2013-01-01

    Three engineering treatments were implemented in a driving simulator study to assess the effect of road-based measures on alleviating the symptoms of fatigue. Using results from previous research on the effect of circadian rhythms on fatigue-related crashes, two groups of male drivers were recruited for this study: young shift workers under the age of 35, who attended immediately after their night shift, and older drivers over the age of 45, who completed the study during the 'post lunch dip' period, after consuming lunch. Eye tracking (PERCLOS) and lateral driver performance measures were used to assess whether baseline measures of fatigue changed after drivers experienced each of the three treatments, which included variable message signs, chevrons and rumble strips. Results showed a marked difference in these measures between drivers' baseline (not fatigued) and experimental (fatigued) visits. There were also some reductions in lateral deviation and eye closure (as measured by PERCLOS) when the treatments were encountered, but no marked difference between the three treatments. These results suggest that in addition to driver- and vehicle-based methods currently employed to mitigate the effects of fatigue, the inclusion of such engineering measures may help alleviate fatigue-related impairments in driving, particularly if such treatments are implemented during long stretches of straight monotonous roads which are known to be associated with fatigue-related crashes. However, positive effects of the treatments were short lived, prompting the need for further investigations on their optimal frequency of presentation and combination to achieve maximum impact from these low-cost, road-based treatments. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  20. Resonant acoustic transducer and driver system for a well drilling string communication system

    DOEpatents

    Chanson, Gary J.; Nicolson, Alexander M.

    1981-01-01

    The acoustic data communication system includes an acoustic transmitter and receiver wherein low frequency acoustic waves, propagating in relatively loss free manner in well drilling string piping, are efficiently coupled to the drill string and propagate at levels competitive with the levels of noise generated by drilling machinery also present in the drill string. The transmitting transducer incorporates a mass-spring piezoelectric transmitter and amplifier combination that permits self-oscillating resonant operation in the desired low frequency range.

  1. Note: An inexpensive square waveform ion funnel driver

    NASA Astrophysics Data System (ADS)

    Hoffman, Nathan M.; Opačić, Bojana; Reilly, Peter T. A.

    2017-01-01

    An inexpensive frequency variable square waveform generator (WFG) was developed to use with existing sinusoidal waveform driven ion funnels. The developed WFG was constructed using readily available low voltage DC power supplies and discrete components placed in printed circuit boards. As applied to ion funnels, this WFG represents considerable cost savings over commercially available products without sacrificing performance. Operation of the constructed pulse generator has been demonstrated for a 1 nF ion funnel at an operating frequency of 1 MHz while switching 48 Vp-p.

  2. Note: An inexpensive square waveform ion funnel driver.

    PubMed

    Hoffman, Nathan M; Opačić, Bojana; Reilly, Peter T A

    2017-01-01

    An inexpensive frequency variable square waveform generator (WFG) was developed to use with existing sinusoidal waveform driven ion funnels. The developed WFG was constructed using readily available low voltage DC power supplies and discrete components placed in printed circuit boards. As applied to ion funnels, this WFG represents considerable cost savings over commercially available products without sacrificing performance. Operation of the constructed pulse generator has been demonstrated for a 1 nF ion funnel at an operating frequency of 1 MHz while switching 48 V p-p .

  3. R&D100: LED Pulser

    ScienceCinema

    Pickett, Lyle; Manin, Julien; Eagle, Ethan

    2018-06-12

    A Sandia National Laboratories' light emitting diode (LED) driver is generating light pulses with shorter duration higher repetition frequency and higher brightness than anything on the market. The Sandia LED Pulser uses custom electronic circuitry to drive high-power LEDs to generate short, bright, high frequency light pulses. A single device can emit up to four different colors - each with independent pulse timing - crucial for light-beam forming in many optical applications and is more economical than current light sources such as lasers.

  4. Off-Resonance Acoustic Levitation Without Rotation

    NASA Technical Reports Server (NTRS)

    Barmatz, M. B.; Allen, J. L.

    1984-01-01

    Orthogonal acoustic-levitation modes excited at slightly different frequencies to control rotation. Rotation of object in square cross-section acoustic-levitation chamber stopped by detuning two orthogonal (x and y) excitation drivers in plane of square cross section. Detuning done using fundamental degenerate modes or odd harmonic modes.

  5. The Design of a 100 GHz CARM (Cyclotron Auto-Resonance Maser) Oscillator Experiment

    DTIC Science & Technology

    1988-09-14

    pulsed-power system must be considered. A model of the voltage pulse that consists of a linear voltage rise from zero to the operating voltage...to vary as the voltage to the 3/2 power in order to model space-charge limited flow from a relativistic diode.. As the current rises in the pulse, the...distribution due to a space-charge-limited, laminar flow of electrons based on a one-dimensional, planar, relativistic model . From the charge distribution

  6. Use-related risk analysis for medical devices based on improved FMEA.

    PubMed

    Liu, Long; Shuai, Ma; Wang, Zhu; Li, Ping

    2012-01-01

    In order to effectively analyze and control use-related risk of medical devices, quantitative methodologies must be applied. Failure Mode and Effects Analysis (FMEA) is a proactive technique for error detection and risk reduction. In this article, an improved FMEA based on Fuzzy Mathematics and Grey Relational Theory is developed to better carry out user-related risk analysis for medical devices. As an example, the analysis process using this improved FMEA method for a certain medical device (C-arm X-ray machine) is described.

  7. Rare discrepancies in a driver gene alteration within histologically heterogeneous primary lung cancers.

    PubMed

    Zhong, Wen-zhao; Su, Jian; Xu, Fang-ping; Zhai, Hao-ran; Zhang, Xu-chao; Yang, Xue-ning; Chen, Zhi-yong; Chen, Zhi-hong; Li, Wei; Dong, Song; Zhou, Qing; Yang, Jin-ji; Liu, Yan-hui; Wu, Yi-long

    2015-11-01

    Most lung adenocarcinomas consist of mixtures of histological subtypes harboring different frequencies of driver gene mutations. However, little is known about intratumoral heterogeneity(ITH) within histologically heterogeneous primary lung cancers. Investigating key driver genes in respective morphological pattern is crucial to personalized treatment. Morphologically different areas within the same surgically resected adenocarcinomas were extracted from tissues to analyze gene status in each growth pattern. Driver genes, epidermal growth factor receptor (EGFR), KRAS and EML4-ALK, were assessed by assays with different sensitivities. Seventy-nine consecutive eligible patients harboring a driver gene (EGFR=65; KRAS=10; EML4-ALK=4) were enrolled. For EGFR mutations, ITH occurred in 13.3% (8/60) by direct sequencing (DS) and 1.7% (1/60) by amplification refractory mutation system (ARMS) (P=0.016) among adenocarcinomas, but consistent within five adeno-squamous cell carcinomas by both methods. ITH among KRAS mutations were detected in 20% (2/10) by DS, whereas consistent (10/10) by high resolution melting. No discrepancies in EML4-ALK rearrangements existed according to fluorescence in situ hybridization. Rare ITHs of EGFR/KRAS/EML4-ALK alterations within histologically heterogeneous primary lung adenocarcinomas existed by methods with higher sensitivity. Discrepancies might be due to abundance of mutant tumor cells and detection assays. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Driving under the influence of alcohol: frequency, reasons, perceived risk and punishment.

    PubMed

    Alonso, Francisco; Pastor, Juan C; Montoro, Luis; Esteban, Cristina

    2015-03-12

    The aim of this study was to gain information useful to improve traffic safety, concerning the following aspects for DUI (Driving Under the Influence): frequency, reasons, perceived risk, drivers' knowledge of the related penalties, perceived likelihood of being punished, drivers' perception of the harshness of punitive measures and drivers' perception of the probability of behavioral change after punishment for DUI. A sample of 1100 Spanish drivers, 678 men and 422 women aged from 14 to 65 years old, took part in a telephone survey using a questionnaire to gather sociodemographic and psychosocial information about drivers, as well as information on enforcement, clustered in five related categories: "Knowledge and perception of traffic norms"; "Opinions on sanctions"; "Opinions on policing"; "Opinions on laws" (in general and on traffic); and "Assessment of the effectiveness of various punitive measures". Results showed around 60% of respondents believe that driving under the influence of alcohol is maximum risk behavior. Nevertheless, 90.2% of the sample said they never or almost never drove under the influence of alcohol. In this case, the main reasons were to avoid accidents (28.3%) as opposed to avoiding sanctions (10.4%). On the contrary, the remaining 9.7% acknowledged they had driven after consuming alcohol. It is noted that the main reasons for doing so were "not having another way to return home" (24.5%) and alcohol consumption being associated with meals (17.3%). Another important finding is that the risk perception of traffic accident as a result of DUI is influenced by variables such as sex and age. With regard to the type of sanctions, 90% think that DUI is punishable by a fine, 96.4% that it may result in temporary or permanent suspension of driving license, and 70% that it can be punished with imprisonment. Knowing how alcohol consumption impairs safe driving and skills, being aware of the associated risks, knowing the traffic regulations concerning DUI, and penalizing it strongly are not enough. Additional efforts are needed to better manage a problem with such important social and practical consequences.

  9. Self-rated Driving and Driving Safety in Older Adults

    PubMed Central

    Ross, Lesley A.; Dodson, Joan; Edwards, Jerri D.; Ackerman, Michelle L.; Ball, Karlene

    2012-01-01

    Many U.S. states rely on older adults to self-regulate their driving and determine when driving is no longer a safe option. However, the relationship of older adults’ self-rated driving in terms of actual driving competency outcomes is unclear. The current study investigates self-rated driving in terms of (1) systematic differences between older adults with high (good/excellent) versus low (poor/fair/average) self-ratings, and (2) the predictive nature of self-rated driving to adverse driving outcomes in older drivers (n=350; mean age 73.9, SD=5.25, range 65–91). Adverse driving outcomes included self-reported incidences of (1) being pulled over by the police, (2) receiving a citation, (3) receiving a recommendation to cease or limit driving, (4) crashes, and (5) state-reported crashes. Results found that older drivers with low self-ratings reported more medical conditions, less driving frequency, and had been given more suggestions to stop/limit their driving; there were no other significant differences between low and high self-raters. Logistic regression revealed older drivers were more likely to have a state-reported crash and receive a suggestion to stop or limit driving. Men were more likely to report all adverse driving outcomes except for receiving a suggestion to stop or limit driving. Regarding self-rated driving, older adults with high ratings were 66% less likely (OR=0.34, 95% CI=0.14–0.85) to have received suggestions to limit or stop driving after accounting for demographics, health and driving frequency. Self-ratings were not predictive of other driving outcomes (being pulled over by the police, receiving a citation, self-reported crashes, or state-reported crashes, ps>.05). Most older drivers (85.14%) rated themselves as either good or excellent drivers regardless of their actual previous citation or crash rates. Self-rated driving is likely not related to actual driving proficiency as indicated by previous crash involvement in older adults. Suggestions from other individuals to limit or cease driving may be more influential on self-ratings. PMID:22664719

  10. Belowground Response to Drought in a Tropical Forest Soil. II. Change in Microbial Function Impacts Carbon Composition

    Treesearch

    Nicholas J. Bouskill; Tana E. Wood; Richard Baran; Zhao Hao; Zaw Ye; Ben P. Bowen; Hsiao Chien Lim; Peter S. Nico; Hoi-Ying Holman; Benjamin Gilbert; Whendee L. Silver; Trent R. Northen; Eoin L. Brodie

    2016-01-01

    Climate model projections for tropical regions show clear perturbation of precipitation patterns leading to increased frequency and severity of drought in some regions. Previous work has shown declining soil moisture to be a strong driver of changes in microbial trait distribution, however...

  11. Long‑term ungulate exclusion reduces fungal symbiont prevalence in native grasslands

    Treesearch

    Jennifer A. Rudgers; Rebecca A. Fletcher; Eric Olivas; Carolyn A. Young; Nikki D. Charlton; Dean E. Pearson; John L. Maron

    2016-01-01

    When symbionts are inherited by offspring, they can have substantial ecological and evolutionary consequences because they occur in all host life stages. Although natural frequencies of inherited symbionts are commonly <100 %, few studies investigate the ecological drivers of variation in symbiont prevalence. In plants, inherited fungal endophytes can...

  12. Global migration of influenza A viruses in swine

    USDA-ARS?s Scientific Manuscript database

    The emergence of the 2009 A/H1N1 pandemic virus underscores the importance of understanding how influenza A viruses evolve in swine on a global scale. To reveal the frequency, patterns and drivers of the spread of swine influenza virus globally, we conducted the largest phylogenetic analysis of swin...

  13. Resolving drivers of variability in estuarine metabolism from in situ and experimental measurements at paired sites in a warm temperate Pensacola Bay, Florida

    EPA Science Inventory

    We investigated the integrated ecosystem properties (gross production, respiration, and net ecosystem metabolism) in the Pensacola Bay estuary, using a combination of instrument deployments and plankton metabolism experiments. High-frequency water quality data were collected from...

  14. 76 FR 64423 - Agency Information Collection Activities; Emergency Approval of a New Information Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-18

    ... Information--To collect motorcoach passengers' responses during five one-shot in-person survey events. Form...--To collect motorcoach drivers' responses during five one-shot in-person survey events. Expiration Date: N/A. This is a new information collection. Frequency of Response: One-time. Estimated Total...

  15. Comprehensive Investigation of Visibility Problems on Highways: Developing Real Time Monitoring and Prediction System for Reduced Visibility and Understanding Traffic and Human Factors Implications

    DOT National Transportation Integrated Search

    2017-07-01

    Instances of fog or fog enhanced with smoke (non-photochemical smog) routinely reduce driver visibility on roadways throughout Georgia. Georgia has the fifth highest reduced-visibilityassociated crash frequency of any state. This report provides a...

  16. Demographic diversity, communication and learning behaviour in healthcare groups.

    PubMed

    Curşeu, Petru Lucian

    2013-01-01

    An integrative model of group learning was tested in a sample of 40 healthcare groups (434 respondents), and the results show that age diversity reduces the frequency of face-to-face communication whereas educational diversity reduces the frequency of virtual communication in healthcare groups. Frequency of communication (both face-to-face and virtual), in turn, positively impacts on the emergence of trust and psychological safety, which are essential drivers of learning behaviours in healthcare groups. Additional results show that average educational achievement within groups is conducive for communication frequency (both face-to-face and virtual), whereas mean age within groups has a negative association with the use of virtual communication in healthcare groups. Copyright © 2012 John Wiley & Sons, Ltd.

  17. Dynamic regime of coherent population trapping and optimization of frequency modulation parameters in atomic clocks.

    PubMed

    Yudin, V I; Taichenachev, A V; Basalaev, M Yu; Kovalenko, D V

    2017-02-06

    We theoretically investigate the dynamic regime of coherent population trapping (CPT) in the presence of frequency modulation (FM). We have formulated the criteria for quasi-stationary (adiabatic) and dynamic (non-adiabatic) responses of atomic system driven by this FM. Using the density matrix formalism for Λ system, the error signal is exactly calculated and optimized. It is shown that the optimal FM parameters correspond to the dynamic regime of atomic-field interaction, which significantly differs from conventional description of CPT resonances in the frame of quasi-stationary approach (under small modulation frequency). Obtained theoretical results are in good qualitative agreement with different experiments. Also we have found CPT-analogue of Pound-Driver-Hall regime of frequency stabilization.

  18. Family communication patterns and teen drivers' attitudes toward driving safety.

    PubMed

    Yang, Jingzhen; Campo, Shelly; Ramirez, Marizen; Krapfl, Julia Richards; Cheng, Gang; Peek-Asa, Corinne

    2013-01-01

    Family communication patterns (FCPs) play an important role in reducing the risk-taking behaviors of teens, such as substance use and safer sex. However, little is known about the relationship between family communication and teen driving safety. We analyzed the baseline data from a randomized trial that included 163 parent-teen dyads, with teens who would be receiving their intermediate driver's license within 3 months. FCPs were divided into four types-pluralistic, protective, consensual, and laissez-faire-and were correlated with the frequency of parent-teen discussions and teens' driving safety attitudes. The ratings on four types of FCPs were distributed quite evenly among teens and parents. Parents and teens agreed on their FCP ratings (p = .64). In families with communication patterns that were laissez-faire, protective, and pluralistic, parents talked to their teens less about safe driving than did parents in families with a consensual communication pattern (p < .01). Moreover, the frequency of parent-teen communication about safe driving was positively associated with teen attitudes toward safe driving (adjusted β = 0.35, p = .03). Health care providers need to encourage parents, particularly those with non-consensual FCPs, to increase frequency of parent-teen interactions. Copyright © 2013 National Association of Pediatric Nurse Practitioners. Published by Mosby, Inc. All rights reserved.

  19. Three-dimensional modeling of a negative ion source with a magnetic filter: impact of biasing the plasma electrode on the plasma asymmetry

    NASA Astrophysics Data System (ADS)

    Fubiani, G.; Boeuf, J. P.

    2015-10-01

    The effect on the plasma characteristics of biasing positively the plasma electrode (PE) in negative ion sources with a magnetic filter is analysed using a 3D particle-in-cell model with Monte-Carlo collisions (PIC-MCC). We specialize to the one driver (i.e. one inductively coupled radio-frequency discharge) BATMAN negative ion source and the 4-drivers (large volume) ELISE device. Both are ITER prototype high power tandem-type negative ion sources developed for the neutral beam injector (NBI) system. The plasma is generated in the driver and diffuses inside the second chamber which is magnetized. Asymmetric plasma profiles originate from the formation of an electric field transverse to the electron current flowing through the magnetic filter (Hall effect). The model shows that the importance of the asymmetry increases with the PE bias potential, i.e. with the electron flow from the driver to the extraction region and depends on the shape of the magnetic filter field. We find that although the plasma density and potential profiles may be more or less asymmetric depending on the filter field configuration, the electron current to the plasma grid is always strongly asymmetric.

  20. Microfabricated Ion Beam Drivers for Magnetized Target Fusion

    NASA Astrophysics Data System (ADS)

    Persaud, Arun; Seidl, Peter; Ji, Qing; Ardanuc, Serhan; Miller, Joseph; Lal, Amit; Schenkel, Thomas

    2015-11-01

    Efficient, low-cost drivers are important for Magnetized Target Fusion (MTF). Ion beams offer a high degree of control to deliver the required mega joules of driver energy for MTF and they can be matched to several types of magnetized fuel targets, including compact toroids and solid targets. We describe an ion beam driver approach based on the MEQALAC concept (Multiple Electrostatic Quadrupole Array Linear Accelerator) with many beamlets in an array of micro-fabricated channels. The channels consist of a lattice of electrostatic quadrupoles (ESQ) for focusing and of radio-frequency (RF) electrodes for ion acceleration. Simulations with particle-in-cell and beam envelope codes predict >10x higher current densities compared to state-of-the-art ion accelerators. This increase results from dividing the total ion beam current up into many beamlets to control space charge forces. Focusing elements can be biased taking advantage of high breakdown electric fields in sub-mm structures formed using MEMS techniques (Micro-Electro-Mechanical Systems). We will present results on ion beam transport and acceleration in MEMS based beamlets. Acknowledgments: This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231.

  1. An Experimental Investigation of Unsteady Thrust Augmentation Using a Speaker-Driven Jet

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.; Wernet, Mark P.; John, Wentworth T.

    2004-01-01

    An experimental investigation is described in which a simple speaker-driven jet was used as a pulsed thrust source (driver) for an ejector configuration. The objectives of the investigation were twofold: first, to add to the experimental body of evidence showing that an unsteady thrust source, combined with a properly sized ejector generally yields higher thrust augmentation values than a similarly sized, steady driver of equivalent thrust. Second, to identify characteristics of the unsteady driver that may be useful for sizing ejectors, and predicting what thrust augmentation values may be achieved. The speaker-driven jet provided a convenient source for the investigation because it is entirely unsteady (having no mean component) and because relevant parameters such as frequency, time-averaged thrust, and diameter are easily variable. The experimental setup will be described, as will the various measurements made. These include both thrust and Digital Particle Imaging Velocimetry of the driver. It will be shown that thrust augmentation values as high as 1.8 were obtained, that the diameter of the best ejector scaled with the dimensions of the emitted vortex, and that the so-called Formation Number serves as a useful dimensionless number by which to characterize the jet and predict performance.

  2. Identification of differences between rural and urban safety cultures.

    PubMed

    Rakauskas, Michael E; Ward, Nicholas J; Gerberich, Susan G

    2009-09-01

    The prevailing risk of traffic fatalities is much larger in rural areas compared to urban areas. A number of explanations have been offered to explain this including road design, emergency medical service proximity, and human factors. This research explored the potential contribution of rural driver attitudes that may underlie the increased fatal crash risk in rural environments. This analysis examined differences between rural and urban drivers in terms of self-reported risk taking for driving behaviors associated with fatal crashes and attitudes toward safety interventions using a large-scale survey. The results suggested that rural drivers engage in riskier behavior, such as not wearing seatbelts, because they have lower perceptions of the risks associated with such behaviors. Results also suggested that vehicle type (e.g., pickup trucks versus passenger vehicles) may be related to seatbelt compliance and frequency of driving under the influence of alcohol. Rural drivers perceived the utility of government-sponsored traffic safety interventions to be lower than their urban counterparts. This study provides insights into the role of the human factor in rural fatal crashes and provides policy suggestions for developing safety interventions that are designed with respect to the psychosocial factors that define the rural culture.

  3. Analysis of the effect of older drivers’ driving behaviors on traffic flow based on a modified CA model

    NASA Astrophysics Data System (ADS)

    Jian, Mei-Ying; Shi, Jing; Liu, Yang

    2016-09-01

    As the global population ages, there are more and more older drivers on the road. The decline in driving performance of older drivers may influence the properties of traffic flow and safety. The purpose of this paper is to investigate the effect of older drivers’ driving behaviors on traffic flow. A modified cellular automaton (CA) model which takes driving behaviors of older drivers into account is proposed. The simulation results indicate that older drivers’ driving behaviors induce a reduction in traffic flow especially when the density is higher than 15 vehicles per km per lane and an increase in Lane-changing frequency. The analysis of stability shows that a number of disturbances could frequently emerge, be propagated and eventually dissipate in this modified model. The results also reflect that with the increase of older drivers on the road, the probability of the occurrence of rear-end collisions increases greatly and obviously. Furthermore, the value of acceleration influences the traffic flow and safety significantly. These results provide the theoretical basis and reference for the traffic management departments to develop traffic management measure in the aging society.

  4. Bus drivers' mental conditions and their relation to bus passengers' accidents with a focus on the psychological stress concept.

    PubMed

    Yamada, Yasuyuki; Mizuno, Motoki; Sugiura, Miyuki; Tanaka, Sumio; Mizuno, Yuki; Yanagiya, Toshio; Hirosawa, Masataka

    2008-06-01

    The purpose of this study was to clarify the psychological factors of bus drivers' instability that were related to bus passengers' accidents according to the hypothesis model based on the stress concept of Lazarus and Folkman (1984). This research was carried out in 2006. Participants of the study were 39 Japanese male bus drivers. Their average age was 40.2 (SD: 11.1). The average duration of employment was 4.5 (SD:6.1) years. A questionnaire was used that was composed of items concerning the frequency of bus passengers' accidents, performance of safe driving, job stressors, stress reaction and recognition from others. Based on the results, a model assuming that stress reaction caused by job stressors disturbed the bus driver's safe driving and was associated with passengers' accidents in the bus was verified to some degree. Especially, melancholy and tired feeling toward passengers showed a strong relation to the passengers' accidents in the bus. This suggested much room for intervention. Moreover, the recognition from others of their job was confirmed to act as a control factor of the stress reaction.

  5. Trends and drivers of fire activity vary across California aridland ecosystems

    USGS Publications Warehouse

    Syphard, Alexandra D.; Keeley, Jon E.; Abatzoglou, John T.

    2017-01-01

    Fire activity has increased in western US aridland ecosystems due to increased human-caused ignitions and the expansion of flammable exotic grasses. Because many desert plants are not adapted to fire, increased fire activity may have long-lasting ecological impacts on native vegetation and the wildlife that depend on it. Given the heterogeneity across aridland ecosystems, it is important to understand how trends and drivers of fire vary, so management can be customized accordingly. We examined historical trends and quantified the relative importance of and interactions among multiple drivers of fire patterns across five aridland ecoregions in southeastern California from 1970 to 2010. Fire frequency increased across all ecoregions for the first couple decades, and declined or plateaued since the 1990s; but area burned continued to increase in some regions. The relative importance of anthropogenic and biophysical drivers varied across ecoregions, with both direct and indirect influences on fire. Anthropogenic variables were equally important as biophysical variables, but some contributed indirectly, presumably via their influence on annual grass distribution and abundance. Grass burned disproportionately more than other cover types, suggesting that addressing exotics may be the key to fire management and conservation in much of the area.

  6. Characteristics of on-road driving performance of persons with central vision loss who use bioptic telescopes.

    PubMed

    Wood, Joanne M; McGwin, Gerald; Elgin, Jennifer; Searcey, Karen; Owsley, Cynthia

    2013-05-01

    To compare the on-road driving performance of visually impaired drivers using bioptic telescopes with age-matched controls. Participants included 23 persons (mean age = 33 ± 12 years) with visual acuity of 20/63 to 20/200 who were legally licensed to drive through a state bioptic driving program, and 23 visually normal age-matched controls (mean age = 33 ± 12 years). On-road driving was assessed in an instrumented dual-brake vehicle along 14.6 miles of city, suburban, and controlled-access highways. Two backseat evaluators independently rated driving performance using a standardized scoring system. Vehicle control was assessed through vehicle instrumentation and video recordings used to evaluate head movements, lane-keeping, pedestrian detection, and frequency of bioptic telescope use. Ninety-six percent (22/23) of bioptic drivers and 100% (23/23) of controls were rated as safe to drive by the evaluators. There were no group differences for pedestrian detection, or ratings for scanning, speed, gap judgments, braking, indicator use, or obeying signs/signals. Bioptic drivers received worse ratings than controls for lane position and steering steadiness and had lower rates of correct sign and traffic signal recognition. Bioptic drivers made significantly more right head movements, drove more often over the right-hand lane marking, and exhibited more sudden braking than controls. Drivers with central vision loss who are licensed to drive through a bioptic driving program can display proficient on-road driving skills. This raises questions regarding the validity of denying such drivers a license without the opportunity to train with a bioptic telescope and undergo on-road evaluation.

  7. Why Do Drivers Use Mobile Phones While Driving? The Contribution of Compensatory Beliefs.

    PubMed

    Zhou, Ronggang; Yu, Mengli; Wang, Xinyi

    2016-01-01

    The current study is the first to investigate the contribution of compensatory beliefs (i.e., the belief that the negative effects of an unsafe behavior can be "neutralized" by engaging in another safe behavior; e.g., "I can use a mobile phone now because I will slow down ") on drivers' mobile phone use while driving. The effects of drivers' personal characteristics on compensatory beliefs, mobile phone use and self-regulatory behaviors were also examined. A series of questions were administered to drivers, which included (1) personal measures, (2) scales that measured compensatory beliefs generally in substance use and with regard to driving safety, and (3) questions to measure drivers' previous primary mobile phone usage and corresponding self-regulatory actions. Overall, drivers reported a low likelihood of compensatory beliefs, prior mobile phone use, and a strong frequency of self-regulatory behaviors. Respondents who had a higher tendency toward compensatory beliefs reported more incidents or crash involvement caused by making or answering calls and sending or reading messages. The findings provide strong support for the contribution of compensatory beliefs in predicting mobile phone usage in the context of driving. Compensatory beliefs can explain 41% and 43% of the variance in the active activities of making calls and texting/sending messages compared with 18% and 31% of the variance in the passive activities of answering calls and reading messages. Among the regression models for predicting self-regulatory behaviors at the tactical or operational level, compensatory beliefs emerge as significant predictors only in predicting shorter conversations while on a call. The findings and limitations of the current study are discussed.

  8. Nitrogen supply modulates the effect of changes in drying-rewetting frequency on soil C and N cycling and greenhouse gas exchange.

    PubMed

    Morillas, Lourdes; Durán, Jorge; Rodríguez, Alexandra; Roales, Javier; Gallardo, Antonio; Lovett, Gary M; Groffman, Peter M

    2015-10-01

    Climate change and atmospheric nitrogen (N) deposition are two of the most important global change drivers. However, the interactions of these drivers have not been well studied. We aimed to assess how the combined effect of soil N additions and more frequent soil drying-rewetting events affects carbon (C) and N cycling, soil:atmosphere greenhouse gas (GHG) exchange, and functional microbial diversity. We manipulated the frequency of soil drying-rewetting events in soils from ambient and N-treated plots in a temperate forest and calculated the Orwin & Wardle Resistance index to compare the response of the different treatments. Increases in drying-rewetting cycles led to reductions in soil NO3- levels, potential net nitrification rate, and soil : atmosphere GHG exchange, and increases in NH4+ and total soil inorganic N levels. N-treated soils were more resistant to changes in the frequency of drying-rewetting cycles, and this resistance was stronger for C- than for N-related variables. Both the long-term N addition and the drying-rewetting treatment altered the functionality of the soil microbial population and its functional diversity. Our results suggest that increasing the frequency of drying-rewetting cycles can affect the ability of soil to cycle C and N and soil : atmosphere GHG exchange and that the response to this increase is modulated by soil N enrichment. © 2015 John Wiley & Sons Ltd.

  9. MR elastography and diffusion-weighted imaging of ex vivo prostate cancer: quantitative comparison to histopathology.

    PubMed

    Sahebjavaher, Ramin S; Nir, Guy; Gagnon, Louis O; Ischia, Joseph; Jones, Edward C; Chang, Silvia D; Yung, Andrew; Honarvar, Mohammad; Fazli, Ladan; Goldenberg, S Larry; Rohling, Robert; Sinkus, Ralph; Kozlowski, Piotr; Salcudean, Septimiu E

    2015-01-01

    The purpose of this work was (1) to develop a magnetic resonance elastography (MRE) system for imaging of the ex vivo human prostate and (2) to assess the diagnostic power of mono-frequency and multi-frequency MRE and diffusion weighted imaging (DWI) alone and combined as correlated with histopathology in a patient study. An electromagnetic driver was designed specifically for MRE studies in small-bore MR scanners. Ex vivo prostate specimens (post-fixation) of 14 patients who underwent radical prostatectomy were imaged with MRE at 7 T (nine cases had DWI). In six patients, the MRE examination was performed at three frequencies (600, 800, 1000 Hz) to extract the power-law exponent Gamma. The images were registered to wholemount pathology slides marked with the Gleason score. The areas under the receiver-operator-characteristic curves (AUC) were calculated. The methods were validated in a phantom study and it was demonstrated that (i) the driver does not interfere with the acquisition process and (ii) the driver can generate amplitudes greater than 100 µm for frequencies less than 1 kHz. In the quantitative study, cancerous tissue with Gleason score at least 3 + 3 was distinguished from normal tissue in the peripheral zone (PZ) with an average AUC of 0.75 (Gd ), 0.75 (Gl ), 0.70 (Gamma-Gd ), 0.68 (apparent diffusion coefficient, ADC), and 0.82 (Gd  + Gl  + ADC). The differentiation between PZ and central gland was modest for Gd (p < 0.07), Gl (p < 0.06) but not significant for Gamma (p < 0.2). A correlation of 0.4 kPa/h was found between the fixation time of the prostate specimen and the stiffness of the tissue, which could affect the diagnostic power results. DWI and MRE may provide complementary information; in fact MRE performed better than ADC in distinguishing normal from cancerous tissue in some cases. Multi-frequency (Gamma) analysis did not appear to improve the results. However, in light of the effect of tissue fixation, the clinical implication of our results may be inconclusive and more experiments are needed. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Nationwide study of publication misrepresentation in applicants to residency.

    PubMed

    Sater, Lara; Schwartz, Joseph S; Coupland, Sarah; Young, Meredith; Nguyen, Lily H P

    2015-06-01

    This study was conducted to assess the prevalence of research publication misrepresentation amongst Canadian Resident Matching Service (CaRMS) applicants to a single surgical subspecialty residency as a potential means of assessing professional behaviour. The authors reviewed CaRMS application forms to Canadian otolaryngology residency programmes over a 3-year period (2006-2008) for peer-reviewed publications reported as 'published', 'accepted' and 'in press'. Citations were verified by searching PubMed, Google Scholar and electronic journals. Misrepresentation was defined as any of: (i) falsely claimed authorship of an existing article; (ii) claimed authorship of a non-existing article, and (iii) improper ordering of authorship. Outcomes included descriptive statistics, as well as sub-analyses pertaining to age, gender, affiliated medical school and academic degree, and number of publications per applicant. A total of 427 peer-reviewed publications were reported by 124 of 182 applicants (68% of applicants reported at least one publication). Of the 385 verifiable publications, 47 (12% of articles) were misrepresented by 29 applicants (23% of applicants claiming publication) self-reporting at least one publication. Age, gender, location of medical training, prior academic degree and number of citations per applicant did not relate to likelihood of misrepresentation (p > 0.05). This study documents the nationwide prevalence of publication misrepresentation amongst applicants to Canadian otolaryngology residency programmes. The high rate of misrepresentation aligns with data reported in the literature and highlights the need to institute measures to dissuade graduates from this form of unprofessional behaviour. © 2015 John Wiley & Sons Ltd.

  11. Surgical screw segmentation for mobile C-arm CT devices

    NASA Astrophysics Data System (ADS)

    Görres, Joseph; Brehler, Michael; Franke, Jochen; Wolf, Ivo; Vetter, Sven Y.; Grützner, Paul A.; Meinzer, Hans-Peter; Nabers, Diana

    2014-03-01

    Calcaneal fractures are commonly treated by open reduction and internal fixation. An anatomical reconstruction of involved joints is mandatory to prevent cartilage damage and premature arthritis. In order to avoid intraarticular screw placements, the use of mobile C-arm CT devices is required. However, for analyzing the screw placement in detail, a time-consuming human-computer interaction is necessary to navigate through 3D images and therefore to view a single screw in detail. Established interaction procedures of repeatedly positioning and rotating sectional planes are inconvenient and impede the intraoperative assessment of the screw positioning. To simplify the interaction with 3D images, we propose an automatic screw segmentation that allows for an immediate selection of relevant sectional planes. Our algorithm consists of three major steps. At first, cylindrical characteristics are determined from local gradient structures with the help of RANSAC. In a second step, a DBScan clustering algorithm is applied to group similar cylinder characteristics. Each detected cluster represents a screw, whose determined location is then refined by a cylinder-to-image registration in a third step. Our evaluation with 309 screws in 50 images shows robust and precise results. The algorithm detected 98% (303) of the screws correctly. Thirteen clusters led to falsely identified screws. The mean distance error for the screw tip was 0.8 +/- 0.8 mm and for the screw head 1.2 +/- 1 mm. The mean orientation error was 1.4 +/- 1.2 degrees.

  12. Quantifying the yellow signal driver behavior based on naturalistic data from digital enforcement cameras.

    PubMed

    Bar-Gera, H; Musicant, O; Schechtman, E; Ze'evi, T

    2016-11-01

    The yellow signal driver behavior, reflecting the dilemma zone behavior, is analyzed using naturalistic data from digital enforcement cameras. The key variable in the analysis is the entrance time after the yellow onset, and its distribution. This distribution can assist in determining two critical outcomes: the safety outcome related to red-light-running angle accidents, and the efficiency outcome. The connection to other approaches for evaluating the yellow signal driver behavior is also discussed. The dataset was obtained from 37 digital enforcement cameras at non-urban signalized intersections in Israel, over a period of nearly two years. The data contain more than 200 million vehicle entrances, of which 2.3% (∼5million vehicles) entered the intersection during the yellow phase. In all non-urban signalized intersections in Israel the green phase ends with 3s of flashing green, followed by 3s of yellow. In most non-urban signalized roads in Israel the posted speed limit is 90km/h. Our analysis focuses on crossings during the yellow phase and the first 1.5s of the red phase. The analysis method consists of two stages. In the first stage we tested whether the frequency of crossings is constant at the beginning of the yellow phase. We found that the pattern was stable (i.e., the frequencies were constant) at 18 intersections, nearly stable at 13 intersections and unstable at 6 intersections. In addition to the 6 intersections with unstable patterns, two other outlying intersections were excluded from subsequent analysis. Logistic regression models were fitted for each of the remaining 29 intersection. We examined both standard (exponential) logistic regression and four parameters logistic regression. The results show a clear advantage for the former. The estimated parameters show that the time when the frequency of crossing reduces to half ranges from1.7 to 2.3s after yellow onset. The duration of the reduction of the relative frequency from 0.9 to 0.1 ranged from 1.9 to 2.9s. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Regional United States electric field and GIC hazard impacts (Invited)

    NASA Astrophysics Data System (ADS)

    Gannon, J. L.; Balch, C. C.; Trichtchenko, L.

    2013-12-01

    Geomagnetically Induced Currents (GICs) are primarily driven by impulsive geomagnetic disturbances created by the interaction between the Earth's magnetosphere and sharp velocity, density, and magnetic field enhancements in the solar wind. However, the magnitude of the induced electric field response at the ground level, and therefore the resulting hazard to the bulk power system, is determined not only by magnetic drivers, but also by the underlying geology. Convolution techniques are used to calculate surface electric fields beginning from the spectral characteristics of magnetic field drivers and the frequency response of the local geology. Using these techniques, we describe historical scenarios for regions across the United States, and the potential impact of large events on electric power infrastructure.

  14. Risk and threat factors in prior representations of driving situations among powered two-wheeler riders and car drivers.

    PubMed

    Ragot-Court, Isabelle; Mundutéguy, Christophe; Fournier, Jean-Yves

    2012-11-01

    Our research objective is to contribute to gaining a better understanding of the difficulties inherent to managing interactions between power two-wheeler riders and car drivers. 132 power two-wheeler riders and 94 car drivers have been asked what they perceive as being riskiest in driving situations for the representatives of their generic reference group. From all the answers produced, only those which provide information on risk factors related to the other and the occurrence of interferences due to the dynamic situation have been retained and analysed. The results provide a partial explanation of the difficulties related to the two types of users' taking each other into account. On the one hand, the frequency with which the other is mentioned as a source of risk is linked to the concept of conspicuity. This interpretation is related to the relative frequency of the interactions and the difference of real and perceived vulnerability between the users. On the other hand, the specific risk factors attributed to the other illustrates a mutual misunderstanding or ignorance of the driving situation's determinants. These include various practices among users which can be related to the physical and dynamic characteristics of their vehicle and their level of familiarity with other users. The potential road safety consequences of prior representations of risk factors among users are presented and suggestions for improving road user safety are proposed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Intraprocedural C-Arm Dual-Phase Cone-Beam CT: Can It Be Used to Predict Short-term Response to TACE with Drug-eluting Beads in Patients with Hepatocellular Carcinoma?

    PubMed Central

    Loffroy, Romaric; Lin, MingDe; Yenokyan, Gayane; Rao, Pramod P.; Bhagat, Nikhil; Noordhoek, Niels; Radaelli, Alessandro; Blijd, Järl; Liapi, Eleni

    2013-01-01

    Purpose: To investigate whether C-arm dual-phase cone-beam computed tomography (CT) performed during transcatheter arterial chemoembolization (TACE) with doxorubicin-eluting beads can help predict tumor response at 1-month follow-up in patients with hepatocellular carcinoma (HCC). Materials and Methods: This prospective study was compliant with HIPAA and approved by the institutional review board and animal care and use committee. Analysis was performed retrospectively on 50 targeted HCC lesions in 29 patients (16 men, 13 women; mean age, 61.9 years ± 10.7) treated with TACE with drug-eluting beads. Magnetic resonance (MR) imaging was performed at baseline and 1 month after TACE. Dual-phase cone-beam CT was performed before and after TACE. Tumor enhancement at dual-phase cone-beam CT in early arterial and delayed venous phases was assessed retrospectively with blinding to MR findings. Tumor response at MR imaging was assessed according to European Association for the Study of the Liver (EASL) guidelines. Two patients were excluded from analysis because dual-phase cone-beam CT scans were not interpretable. Logistic regression models for correlated data were used to compare changes in tumor enhancement between modalities. The radiation dose with dual-phase cone-beam CT was measured in one pig. Results: At 1-month MR imaging follow-up, complete and/or partial tumor response was seen in 74% and 76% of lesions in the arterial and venous phases, respectively. Paired t tests used to compare images obtained before and after TACE showed a significant reduction in tumor enhancement with both modalities (P < .0001). The decrease in tumor enhancement seen with dual-phase cone-beam CT after TACE showed a linear correlation with MR findings. Estimated correlation coefficients were excellent for first (R = 0.89) and second (R = 0.82) phases. A significant relationship between tumor enhancement at cone-beam CT after TACE and complete and/or partial tumor response at MR imaging was found for arterial (odds ratio, 0.95; 95% confidence interval [CI]: 0.91, 0.99; P = .023) and venous (odds ratio, 0.96; 95% CI: 0.93, 0.99; P = .035) phases with the multivariate logistic regression model. Radiation dose for two dual-phase cone-beam CT scans was 3.08 mSv. Conclusion: Intraprocedural C-arm dual-phase cone-beam CT can be used immediately after TACE with doxorubicin-eluting beads to predict HCC tumor response at 1-month MR imaging follow-up. © RSNA, 2012 PMID:23143027

  16. [Case-control study on needle-knife to cut off the medial branch of the lumbar posterior ramus under C-arm guiding for the treatment of low back pain caused by lumbar facet osteoarthritis].

    PubMed

    Lu, Di; Xu, Wei-xing; Ding, Wei-Guo; Guo, Qiao-Feng; Ma, Gou-ping; Zhu, Wei-min

    2013-03-01

    To study the clinical efficacy of needle-knife to cut off the medial branch of the lumbar posterior ramus under C-arm guiding to treat low back pain caused by lumbar facet osteoarthritis. From July 2009 to June 2011, 60 patients with low back pain caused by lumbar facet osteoarthritis were reviewed,including 34 males and 26 females, ranging in age from 39 to 73 years old,averaged 61.9 years old; the duration of the disease ranged from 6 to 120 months, with a mean of 18.9 months. All the patients were divided into two groups, 30 patients (18 males and 12 females, ranging in age from 39 to 71 years old, needle-knife group) were treated with needle-knife to cut off medial branch of the lumbar posterior ramus under C -arm guiding and the other 30 patients(16 males and 14 females, ranging in age from 41 to 73 years old, hormone injection group) were treated with hormone injection in lumbar facet joint under C-arm guiding. The preoperative JOA scores and the scores at the 1st, 12th and 26th weeks after treatment were analyzed. Before treatment,the JOA scores between the two groups had no significant difference (P= 0.479); after 1 week of treatment, the JOA scores between the two groups had significant difference (P= 0.040), the improvement rate of hormone injection group was superior than that of the needle-knife group,which were (58.73+/-18.20)% in needle-knife group and (71.10+/-22.19)% in hormone injection group; after 12 weeks of treatment, the JOA scores between the two groups had no significant difference(P=0.569), and the improvement rate between the two groups had no significant difference,which were (50.09+/-19.33)% in the needle-knife group and (48.70+/-18.36)%) in the hormone injection group; after 26 weeks of treatment,the JOA scores between the two groups had significant difference (P=0.000), the improvement rate of hormone injection group was superior than that of the needle-knife group,which were (48.56+/-28.24)% in needle-knife group and (15.62+/-11.23 )% in hormone injection group. Using needle-knife to cut off the medial branch of the lumbar posterior ramus could get longer efficacy than hormone injection in the treatment of lumbar facet osteoarthritis.

  17. Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    PubMed Central

    2012-01-01

    Background The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. Methods The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required. Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. Results A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). Conclusions In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses. PMID:22276698

  18. Depression of the Thoracolumbar Posterior Vertebral Body on the Estimation of Cement Leakage in Vertebroplasty and Kyphoplasty Operations

    PubMed Central

    Chen, Hao; Jia, Pu; Bao, Li; Feng, Fei; Yang, He; Li, Jin-Jun; Tang, Hai

    2015-01-01

    Background: The cross-section of thoracolumbar vertebral body is kidney-shaped with depressed posterior boundary. The anterior wall of the vertebral canal is separated from the posterior wall of the vertebral body on the lateral X-ray image. This study was designed to determine the sagittal distance between the anterior border of the vertebral canal and the posterior border of the vertebral body (DBCV) and to analyze the potential role of DBCV in the estimation of cement leakage during percutaneous vertebroplasty (PVP) or percutaneous kyphoplasty (PKP). Methods: We retrospectively recruited 233 patients who had osteoporotic vertebral compression fractures and were treated with PVP or PKP. Computed tomography images of T11–L2 normal vertebrae were measured to obtain DBCV. The distance from cement to the posterior wall of the vertebral body (DCPW) of thoracolumbar vertebrae was measured from C-arm images. The selected vertebrae were divided into two groups according to DCPW, with the fracture levels, fracture grades and leakage rates of the two groups compared. A relative operating characteristic (ROC) curve was applied to determine whether the DCPW difference can be used to estimate the degree of cement leakage. The data were processed by statistical software SPSS version 21.0 using independent sample t-test and Chi-square tests. Results: The maximum DBCV was 6.40 mm and the average DBCV was 3.74 ± 0.95 mm. DBCV appeared to be longer in males than in females, but the difference was not statistically significant. The average DCPW of type-B leakage vertebrae (2.59 ± 1.20 mm) was shorter than that of other vertebrae (7.83 ± 2.38 mm, P < 0.001). The leakage rate of group DCPW ≤6.40 mm was lower than that of group DCPW >6.40 mm for type-C and type-S, but much higher for type-B. ROC curve revealed that DCPW only has a predictive value for type-B leakage (area under the curve: 0.98, 95% confidence interval: 0.95–0.99, P < 0.001), and when the cut-off value was 4.05 mm, the diagnostic sensitivity and the specificity were 94.87% and 93.02%, respectively. Conclusions: Depression of the thoracolumbar posterior vertebral body may be informative for the estimation of cement location on C-arm images. To reduce type-B leakage, DCPW should be made longer than DBCV on C-arm images for safety during PVP or PKP. PMID:26612289

  19. Depression of the Thoracolumbar Posterior Vertebral Body on the Estimation of Cement Leakage in Vertebroplasty and Kyphoplasty Operations.

    PubMed

    Chen, Hao; Jia, Pu; Bao, Li; Feng, Fei; Yang, He; Li, Jin-Jun; Tang, Hai

    2015-12-05

    The cross-section of thoracolumbar vertebral body is kidney-shaped with depressed posterior boundary. The anterior wall of the vertebral canal is separated from the posterior wall of the vertebral body on the lateral X-ray image. This study was designed to determine the sagittal distance between the anterior border of the vertebral canal and the posterior border of the vertebral body (DBCV) and to analyze the potential role of DBCV in the estimation of cement leakage during percutaneous vertebroplasty (PVP) or percutaneous kyphoplasty (PKP). We retrospectively recruited 233 patients who had osteoporotic vertebral compression fractures and were treated with PVP or PKP. Computed tomography images of T11-L2 normal vertebrae were measured to obtain DBCV. The distance from cement to the posterior wall of the vertebral body (DCPW) of thoracolumbar vertebrae was measured from C-arm images. The selected vertebrae were divided into two groups according to DCPW, with the fracture levels, fracture grades and leakage rates of the two groups compared. A relative operating characteristic (ROC) curve was applied to determine whether the DCPW difference can be used to estimate the degree of cement leakage. The data were processed by statistical software SPSS version 21.0 using independent sample t-test and Chi-square tests. The maximum DBCV was 6.40 mm and the average DBCV was 3.74 ± 0.95 mm. DBCV appeared to be longer in males than in females, but the difference was not statistically significant. The average DCPW of type-B leakage vertebrae (2.59 ± 1.20 mm) was shorter than that of other vertebrae (7.83 ± 2.38 mm, P < 0.001). The leakage rate of group DCPW ≤6.40 mm was lower than that of group DCPW >6.40 mm for type-C and type-S, but much higher for type-B. ROC curve revealed that DCPW only has a predictive value for type-B leakage (area under the curve: 0.98, 95% confidence interval: 0.95-0.99, P < 0.001), and when the cut-off value was 4.05 mm, the diagnostic sensitivity and the specificity were 94.87% and 93.02%, respectively. Depression of the thoracolumbar posterior vertebral body may be informative for the estimation of cement location on C-arm images. To reduce type-B leakage, DCPW should be made longer than DBCV on C-arm images for safety during PVP or PKP.

  20. Landscape of somatic mutations in 560 breast cancer whole-genome sequences

    DOE PAGES

    Nik-Zainal, Serena; Davies, Helen; Staaf, Johan; ...

    2016-05-02

    Here, we analysed whole-genome sequences of 560 breast cancers to advance understanding of the driver mutations conferring clonal advantage and the mutational processes generating somatic mutations. We found that 93 protein-coding cancer genes carried probable driver mutations. Some non-coding regions exhibited high mutation frequencies, but most have distinctive structural features probably causing elevated mutation rates and do not contain driver mutations. Mutational signature analysis was extended to genome rearrangements and revealed twelve base substitution and six rearrangement signatures. Three rearrangement signatures, characterized by tandem duplications or deletions, appear associated with defective homologous-recombination-based DNA repair: one with deficient BRCA1 function, anothermore » with deficient BRCA1 or BRCA2 function, the cause of the third is unknown. This analysis of all classes of somatic mutation across exons, introns and intergenic regions highlights the repertoire of cancer genes and mutational processes operating, and progresses towards a comprehensive account of the somatic genetic basis of breast cancer.« less

  1. Landscape of somatic mutations in 560 breast cancer whole-genome sequences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nik-Zainal, Serena; Davies, Helen; Staaf, Johan

    Here, we analysed whole-genome sequences of 560 breast cancers to advance understanding of the driver mutations conferring clonal advantage and the mutational processes generating somatic mutations. We found that 93 protein-coding cancer genes carried probable driver mutations. Some non-coding regions exhibited high mutation frequencies, but most have distinctive structural features probably causing elevated mutation rates and do not contain driver mutations. Mutational signature analysis was extended to genome rearrangements and revealed twelve base substitution and six rearrangement signatures. Three rearrangement signatures, characterized by tandem duplications or deletions, appear associated with defective homologous-recombination-based DNA repair: one with deficient BRCA1 function, anothermore » with deficient BRCA1 or BRCA2 function, the cause of the third is unknown. This analysis of all classes of somatic mutation across exons, introns and intergenic regions highlights the repertoire of cancer genes and mutational processes operating, and progresses towards a comprehensive account of the somatic genetic basis of breast cancer.« less

  2. Performance evaluation of a permanent ring magnet based helicon plasma source for negative ion source research

    NASA Astrophysics Data System (ADS)

    Pandey, Arun; Bandyopadhyay, M.; Sudhir, Dass; Chakraborty, A.

    2017-10-01

    Helicon wave heated plasmas are much more efficient in terms of ionization per unit power consumed. A permanent magnet based compact helicon wave heated plasma source is developed in the Institute for Plasma Research, after carefully optimizing the geometry, the frequency of the RF power, and the magnetic field conditions. The HELicon Experiment for Negative ion-I source is the single driver helicon plasma source that is being studied for the development of a large sized, multi-driver negative hydrogen ion source. In this paper, the details about the single driver machine and the results from the characterization of the device are presented. A parametric study at different pressures and magnetic field values using a 13.56 MHz RF source has been carried out in argon plasma, as an initial step towards source characterization. A theoretical model is also presented for the particle and power balance in the plasma. The ambipolar diffusion process taking place in a magnetized helicon plasma is also discussed.

  3. Wound management for the 21st century: combining effectiveness and efficiency.

    PubMed

    Lindholm, Christina; Searle, Richard

    2016-07-01

    Treatment of wounds of different aetiologies constitutes a major part of the total health care budget. It is estimated that 1·5-2 million people in Europe suffer from acute or chronic wounds. These wounds are managed both in hospitals and in community care. The patients suffering from these wounds report physical, mental and social consequences of their wounds and the care of them. It is often believed that the use of wound dressings per se is the major cost driver in wound management, whereas in fact, nursing time and hospital costs are together responsible for around 80-85% of the total cost. Healing time, frequency of dressing change and complications are three important cost drivers. However, with the use of modern, advanced technology for more rapid wound healing, all these cost drivers can be substantially reduced. A basic understanding of the terminology and principles of Health Economics in relation to wound management might therefore be of interest. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  4. Performance evaluation of a permanent ring magnet based helicon plasma source for negative ion source research.

    PubMed

    Pandey, Arun; Bandyopadhyay, M; Sudhir, Dass; Chakraborty, A

    2017-10-01

    Helicon wave heated plasmas are much more efficient in terms of ionization per unit power consumed. A permanent magnet based compact helicon wave heated plasma source is developed in the Institute for Plasma Research, after carefully optimizing the geometry, the frequency of the RF power, and the magnetic field conditions. The HELicon Experiment for Negative ion-I source is the single driver helicon plasma source that is being studied for the development of a large sized, multi-driver negative hydrogen ion source. In this paper, the details about the single driver machine and the results from the characterization of the device are presented. A parametric study at different pressures and magnetic field values using a 13.56 MHz RF source has been carried out in argon plasma, as an initial step towards source characterization. A theoretical model is also presented for the particle and power balance in the plasma. The ambipolar diffusion process taking place in a magnetized helicon plasma is also discussed.

  5. Identification of significantly mutated regions across cancer types highlights a rich landscape of functional molecular alterations

    PubMed Central

    Araya, Carlos L.; Cenik, Can; Reuter, Jason A.; Kiss, Gert; Pande, Vijay S.; Snyder, Michael P.; Greenleaf, William J.

    2015-01-01

    Cancer sequencing studies have primarily identified cancer-driver genes by the accumulation of protein-altering mutations. An improved method would be annotation-independent, sensitive to unknown distributions of functions within proteins, and inclusive of non-coding drivers. We employed density-based clustering methods in 21 tumor types to detect variably-sized significantly mutated regions (SMRs). SMRs reveal recurrent alterations across a spectrum of coding and non-coding elements, including transcription factor binding sites and untranslated regions mutated in up to ∼15% of specific tumor types. SMRs reveal spatial clustering of mutations at molecular domains and interfaces, often with associated changes in signaling. Mutation frequencies in SMRs demonstrate that distinct protein regions are differentially mutated among tumor types, as exemplified by a linker region of PIK3CA in which biophysical simulations suggest mutations affect regulatory interactions. The functional diversity of SMRs underscores both the varied mechanisms of oncogenic misregulation and the advantage of functionally-agnostic driver identification. PMID:26691984

  6. Validation of the Australian Propensity for Angry Driving Scale (Aus-PADS).

    PubMed

    Leal, Nerida L; Pachana, Nancy A

    2009-09-01

    The present study used a university sample to assess the test-retest reliability and validity of the Australian Propensity for Angry Driving Scale (Aus-PADS). The scale has stability over time, and convergent validity was established, as Aus-PADS scores correlated significantly with established anger and impulsivity measures. Discriminant validity was also established, as Aus-PADS scores did not correlate with Venturesomeness scores. The Aus-PADS has demonstrated criterion validity, as scores were correlated with behavioural measures, such as yelling at other drivers, gesturing at other drivers, and feeling angry but not doing anything. Aus-PADS scores reliably predicted the frequency of these behaviours over and above other study variables. No significant relationship between aggressive driving and crash involvement was observed. It was concluded that the Aus-PADS is a reliable and valid tool appropriate for use in Australian research, and that the potential relationship between aggressive driving and crash involvement warrants further investigation with a more representative (and diverse) driver sample.

  7. Landscape of somatic mutations in 560 breast cancer whole genome sequences

    PubMed Central

    Nik-Zainal, Serena; Davies, Helen; Staaf, Johan; Ramakrishna, Manasa; Glodzik, Dominik; Zou, Xueqing; Martincorena, Inigo; Alexandrov, Ludmil B.; Martin, Sancha; Wedge, David C.; Van Loo, Peter; Ju, Young Seok; Smid, Marcel; Brinkman, Arie B; Morganella, Sandro; Aure, Miriam R.; Lingjærde, Ole Christian; Langerød, Anita; Ringnér, Markus; Ahn, Sung-Min; Boyault, Sandrine; Brock, Jane E.; Broeks, Annegien; Butler, Adam; Desmedt, Christine; Dirix, Luc; Dronov, Serge; Fatima, Aquila; Foekens, John A.; Gerstung, Moritz; Hooijer, Gerrit KJ; Jang, Se Jin; Jones, David R.; Kim, Hyung-Yong; King, Tari A.; Krishnamurthy, Savitri; Lee, Hee Jin; Lee, Jeong-Yeon; Li, Yilong; McLaren, Stuart; Menzies, Andrew; Mustonen, Ville; O’Meara, Sarah; Pauporté, Iris; Pivot, Xavier; Purdie, Colin A.; Raine, Keiran; Ramakrishnan, Kamna; Rodríguez-González, F. Germán; Romieu, Gilles; Sieuwerts, Anieta M.; Simpson, Peter T; Shepherd, Rebecca; Stebbings, Lucy; Stefansson, Olafur A; Teague, Jon; Tommasi, Stefania; Treilleux, Isabelle; Van den Eynden, Gert G.; Vermeulen, Peter; Vincent-Salomon, Anne; Yates, Lucy; Caldas, Carlos; van’t Veer, Laura; Tutt, Andrew; Knappskog, Stian; Tan, Benita Kiat Tee; Jonkers, Jos; Borg, Åke; Ueno, Naoto T; Sotiriou, Christos; Viari, Alain; Futreal, P. Andrew; Campbell, Peter J; Span, Paul N.; Van Laere, Steven; Lakhani, Sunil R; Eyfjord, Jorunn E.; Thompson, Alastair M.; Birney, Ewan; Stunnenberg, Hendrik G; van de Vijver, Marc J; Martens, John W.M.; Børresen-Dale, Anne-Lise; Richardson, Andrea L.; Kong, Gu; Thomas, Gilles; Stratton, Michael R.

    2016-01-01

    We analysed whole genome sequences of 560 breast cancers to advance understanding of the driver mutations conferring clonal advantage and the mutational processes generating somatic mutations. 93 protein-coding cancer genes carried likely driver mutations. Some non-coding regions exhibited high mutation frequencies but most have distinctive structural features probably causing elevated mutation rates and do not harbour driver mutations. Mutational signature analysis was extended to genome rearrangements and revealed 12 base substitution and six rearrangement signatures. Three rearrangement signatures, characterised by tandem duplications or deletions, appear associated with defective homologous recombination based DNA repair: one with deficient BRCA1 function; another with deficient BRCA1 or BRCA2 function; the cause of the third is unknown. This analysis of all classes of somatic mutation across exons, introns and intergenic regions highlights the repertoire of cancer genes and mutational processes operative, and progresses towards a comprehensive account of the somatic genetic basis of breast cancer. PMID:27135926

  8. ASCERTAINMENT OF ON-ROAD SAFETY ERRORS BASED ON VIDEO REVIEW

    PubMed Central

    Dawson, Jeffrey D.; Uc, Ergun Y.; Anderson, Steven W.; Dastrup, Elizabeth; Johnson, Amy M.; Rizzo, Matthew

    2011-01-01

    Summary Using an instrumented vehicle, we have studied several aspects of the on-road performance of healthy and diseased elderly drivers. One goal from such studies is to ascertain the type and frequency of driving safety errors. Because the judgment of such errors is somewhat subjective, we applied a taxonomy system of 15 general safety error categories and 76 specific safety error types. We also employed and trained professional driving instructors to review the video data of the on-road drives. In this report, we illustrate our rating system on a group of 111 drivers, ages 65 to 89. These drivers made errors in 13 of the 15 error categories, comprising 42 of the 76 error types. A mean (SD) of 35.8 (12.8) safety errors per drive were noted, with 2.1 (1.7) of them being judged as serious. Our methodology may be useful in applications such as intervention studies, and in longitudinal studies of changes in driving abilities in patients with declining cognitive ability. PMID:24273753

  9. Parenting behaviors during risky driving by teens with attention-deficit/hyperactivity disorder.

    PubMed

    Schatz, Nicole K; Fabiano, Gregory A; Morris, Karen L; Shucard, Jennifer M; Leo, Brittany A; Bieniek, Courtney

    2014-03-01

    Parenting practices for teen drivers with ADHD were observed via a video monitor installed in vehicles. All teens had recently completed a driver education course and were in the driving permit stage of a graduated driver-licensing program. Parent behaviors were coded during drives when teens were driving safely and during drives when teens engaged in risky driving. The overall frequency of positive parenting strategies was low, regardless of whether teens drove safely or engaged in risky driving. Although the rate of negative feedback was also low, parents engaged in significantly more criticism and were rated by an observer to appear angrier when teens were driving in a risky manner. No other differences in parent behaviors associated with the quality of teen driving were observed. The inconsistencies between observed parenting behaviors and those parenting practices recommended as effective with teens with ADHD are discussed. The need for further research addressing effective strategies for teaching teens with ADHD to drive is highlighted. © 2013.

  10. Effects of fire frequency on litter decomposition as mediated by changes to litter chemistry and soil environmental conditions.

    PubMed

    Ficken, Cari D; Wright, Justin P

    2017-01-01

    Litter quality and soil environmental conditions are well-studied drivers influencing decomposition rates, but the role played by disturbance legacy, such as fire history, in mediating these drivers is not well understood. Fire history may impact decomposition directly, through changes in soil conditions that impact microbial function, or indirectly, through shifts in plant community composition and litter chemistry. Here, we compared early-stage decomposition rates across longleaf pine forest blocks managed with varying fire frequencies (annual burns, triennial burns, fire-suppression). Using a reciprocal transplant design, we examined how litter chemistry and soil characteristics independently and jointly influenced litter decomposition. We found that both litter chemistry and soil environmental conditions influenced decomposition rates, but only the former was affected by historical fire frequency. Litter from annually burned sites had higher nitrogen content than litter from triennially burned and fire suppression sites, but this was correlated with only a modest increase in decomposition rates. Soil environmental conditions had a larger impact on decomposition than litter chemistry. Across the landscape, decomposition differed more along soil moisture gradients than across fire management regimes. These findings suggest that fire frequency has a limited effect on litter decomposition in this ecosystem, and encourage extending current decomposition frameworks into disturbed systems. However, litter from different species lost different masses due to fire, suggesting that fire may impact decomposition through the preferential combustion of some litter types. Overall, our findings also emphasize the important role of spatial variability in soil environmental conditions, which may be tied to fire frequency across large spatial scales, in driving decomposition rates in this system.

  11. Effects of fire frequency on litter decomposition as mediated by changes to litter chemistry and soil environmental conditions

    PubMed Central

    Wright, Justin P.

    2017-01-01

    Litter quality and soil environmental conditions are well-studied drivers influencing decomposition rates, but the role played by disturbance legacy, such as fire history, in mediating these drivers is not well understood. Fire history may impact decomposition directly, through changes in soil conditions that impact microbial function, or indirectly, through shifts in plant community composition and litter chemistry. Here, we compared early-stage decomposition rates across longleaf pine forest blocks managed with varying fire frequencies (annual burns, triennial burns, fire-suppression). Using a reciprocal transplant design, we examined how litter chemistry and soil characteristics independently and jointly influenced litter decomposition. We found that both litter chemistry and soil environmental conditions influenced decomposition rates, but only the former was affected by historical fire frequency. Litter from annually burned sites had higher nitrogen content than litter from triennially burned and fire suppression sites, but this was correlated with only a modest increase in decomposition rates. Soil environmental conditions had a larger impact on decomposition than litter chemistry. Across the landscape, decomposition differed more along soil moisture gradients than across fire management regimes. These findings suggest that fire frequency has a limited effect on litter decomposition in this ecosystem, and encourage extending current decomposition frameworks into disturbed systems. However, litter from different species lost different masses due to fire, suggesting that fire may impact decomposition through the preferential combustion of some litter types. Overall, our findings also emphasize the important role of spatial variability in soil environmental conditions, which may be tied to fire frequency across large spatial scales, in driving decomposition rates in this system. PMID:29023560

  12. Cover cropping frequency is the main driver of soil microbial changes during six years of organic vegetable production

    USDA-ARS?s Scientific Manuscript database

    Soil microbes play a key role in soil health, and understanding the functional role of this living component of soil organic matter is critical to developing sustainable systems in major vegetable production regions like Salinas, California. Soil microbial community size and composition was evaluat...

  13. Forced Vibrations of a Cantilever Beam

    ERIC Educational Resources Information Center

    Repetto, C. E.; Roatta, A.; Welti, R. J.

    2012-01-01

    The theoretical and experimental solutions for vibrations of a vertical-oriented, prismatic, thin cantilever beam are studied. The beam orientation is "downwards", i.e. the clamped end is above the free end, and it is subjected to a transverse movement at a selected frequency. Both the behaviour of the device driver and the beam's weak-damping…

  14. Safety Changes in the US Vehicle Fleet since Model Year 1990, Based on NASS Data

    PubMed Central

    Eigen, Ana Maria; Digges, Kennerly; Samaha, Randa Radwan

    2012-01-01

    Based on the National Automotive Sampling System Crashworthiness Data System since the 1988–1992 model years, there has been a reduction in the MAIS 3+ injury rate and the Mean HARM for all crash modes. The largest improvement in vehicle safety has been in rollovers. There was an increase in the rollover injury rate in the 1993–1998 model year period, but a reduction since then. When comparing vehicles of the model year 1993 to 1998 with later model vehicles, the most profound difference was the reduction of rollover frequency for SUV’s – down more than 20% when compared to other crash modes. When considering only model years since 2002 the rollover frequency reduction was nearly 40%. A 26% reduction in the rate of moderate and serious injuries for all drivers in rollovers was observed for the model years later than 1998. The overall belt use rate for drivers of late model vehicles with HARM weighted injuries was 62% - up from 54% in earlier model vehicles. However, in rollover crashes, the same belt use rate lagged at 54%. PMID:23169134

  15. Thin-Layer Composite Unimorph Ferroelectric Driver Sensor Properties

    NASA Technical Reports Server (NTRS)

    Mossi, Karla M.; Selby, Gregory V.; Bryant, Robert G.

    1998-01-01

    Tests were conducted on 13 different configurations of a new class of piezoelectric devices called THUNDER (thin layer composite unimorph ferroelectric driver and sensor). These configurations consisted of a combination of 1, 3, 5, 7, and 9 layers of 25.4 micron thick aluminium as a backing material, with and without a top layer of 25.4 micrometer aluminum. All of these configurations used the same piezoelectric ceramic wafer (PZT-5A) with dimensions of 5.08 x 3.81 x 0.018 cm. The above configurations were tested at two stages of the manufacturing process: before and after repoling. The parameters measured included frequency, driving voltage. displacement, capacitance, and radius of curvature. An optic sensor recorded the displacement at a fixed voltage(100 - 400 V peak to peak) over a predetermined frequency range (1 - 1000 Hz). These displacement measurements were performed using a computer that controlled the process of activating and measuring the displacement of the device. A parameter alpha was defined which can be used to predict the which configuration will produce the most displacement for a free standing device.

  16. Hitchhiking and epistasis give rise to cohort dynamics in adapting populations

    PubMed Central

    Buskirk, Sean W.; Peace, Ryan Emily; Lang, Gregory I.

    2017-01-01

    Beneficial mutations are the driving force of adaptive evolution. In asexual populations, the identification of beneficial alleles is confounded by the presence of genetically linked hitchhiker mutations. Parallel evolution experiments enable the recognition of common targets of selection; yet these targets are inherently enriched for genes of large target size and mutations of large effect. A comprehensive study of individual mutations is necessary to create a realistic picture of the evolutionarily significant spectrum of beneficial mutations. Here we use a bulk-segregant approach to identify the beneficial mutations across 11 lineages of experimentally evolved yeast populations. We report that nearly 80% of detected mutations have no discernible effects on fitness and less than 1% are deleterious. We determine the distribution of driver and hitchhiker mutations in 31 mutational cohorts, groups of mutations that arise synchronously from low frequency and track tightly with one another. Surprisingly, we find that one-third of cohorts lack identifiable driver mutations. In addition, we identify intracohort synergistic epistasis between alleles of hsl7 and kel1, which arose together in a low-frequency lineage. PMID:28720700

  17. Measuring and improving student engagement in clinical training.

    PubMed

    Lee, Simin; Valtis, Yannis K; Jun, Tomi; Wang, David; Zhang, Biqi; Chung, Esther H; Yu, Amy; Williams, Rachael; Cohen, Marya J

    2018-01-01

    Volunteer service learning activities, including Student Run Clinics (SRCs), are becoming an increasingly popular extracurricular component of medical education. While there are reports that student clinicians generally enjoy their educational experiences at SRCs, it is not understood how to optimize and measure student engagement in them. To identify key drivers of student engagement a tool was created to measure volunteer experience at the Crimson Care Collaborative (CCC), a primary care SRC. CCC volunteers were asked to complete an online engagement survey. Cross-sectional survey data were collected for 149 CCC volunteers (53% response rate). Multivariate linear regression showed that overall 'likelihood to recommend CCC to a friend' was significantly associated with students' perception of the clarity of their role within the clinic, frequency of interprofessional interactions, and overall quality of medical education. Students who volunteer more frequently and for longer periods of time had higher engagement scores. Measuring engagement is feasible in volunteer settings. Engagement appears to be dependent on both structural and experiential components. Easily modifiable components of job design (role definition, expected frequency of volunteering), are key drivers of volunteer engagement.

  18. Compact sub-nanosecond pulse seed source with diode laser driven by a high-speed circuit

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoqian; Wang, Bo; Wang, Junhua; Cheng, Wenyong

    2018-06-01

    A compact sub-nanosecond pulse seed source with 1550 nm diode laser (DL) was obtained by employing a high-speed circuit. The circuit mainly consisted of a short pulse generator and a short pulse driver. The short pulse generator, making up of a complex programmable logic device (CPLD), a level translator, two programmable delay chips and an AND gate chip, output a triggering signal to control metal-oxide-semiconductor field-effect transistor (MOSFET) switch of the short pulse driver. The MOSFET switch with fast rising time and falling time both shorter than 1 ns drove the DL to emit short optical pulses. Performances of the pulse seed source were tested. The results showed that continuously adjustable repetition frequency ranging from 500 kHz to 100 MHz and pulse duration in the range of 538 ps to 10 ns were obtained, respectively. 537 μW output was obtained at the highest repetition frequency of 100 MHz with the shortest pulse duration of 538 ps. These seed pulses were injected into an fiber amplifier, and no optical pulse distortions were found.

  19. Climate change, flooding, urbanisation and leptospirosis: fuelling the fire?

    PubMed

    Lau, Colleen L; Smythe, Lee D; Craig, Scott B; Weinstein, Philip

    2010-10-01

    Flooding and heavy rainfall have been associated with numerous outbreaks of leptospirosis around the world. With global climate change, extreme weather events such as cyclones and floods are expected to occur with increasing frequency and greater intensity and may potentially result in an upsurge in the disease incidence as well as the magnitude of leptospirosis outbreaks. In this paper, we examine mechanisms by which climate change can affect various ecological factors that are likely to drive an increase in the overall incidence as well as the frequency of outbreaks of leptospirosis. We will discuss the geographical areas that are most likely to be at risk of an increase in leptospirosis disease burden owing to the coexistence of climate change hazard risk, environmental drivers of leptospirosis outbreaks, local socioeconomic circumstances, and social and demographic trends. To reduce this disease burden, enhanced surveillance and further research is required to understand the environmental drivers of infection, to build capacity in emergency response and to promote community adaptation to a changing climate. Copyright © 2010 Royal Society of Tropical Medicine and Hygiene.

  20. ITER Plasma at Electron Cyclotron Frequency Domain: Stimulated Raman Scattering off Gould-Trivelpiece Modes and Generation of Suprathermal Electrons and Energetic Ions

    NASA Astrophysics Data System (ADS)

    Stefan, V. Alexander

    2011-04-01

    Stimulated Raman scattering in the electron cyclotron frequency range of the X-Mode and O-Mode driver with the ITER plasma leads to the ``tail heating'' via the generation of suprathermal electrons and energetic ions. The scattering off Trivelpiece-Gould (T-G) modes is studied for the gyrotron frequency of 170GHz; X-Mode and O-Mode power of 24 MW CW; on-axis B-field of 10T. The synergy between the two-plasmon decay and Raman scattering is analyzed in reference to the bulk plasma heating. Supported in part by Nikola TESLA Labs, La Jolla, CA

  1. Association of Heart Rate Variability in Taxi Drivers with Marked Changes in Particulate Air Pollution in Beijing in 2008

    PubMed Central

    Wu, Shaowei; Deng, Furong; Niu, Jie; Huang, Qinsheng; Liu, Youcheng; Guo, Xinbiao

    2010-01-01

    Background Heart rate variability (HRV), a marker of cardiac autonomic function, has been associated with particulate matter (PM) air pollution, especially in older patients and those with cardiovascular diseases. However, the effect of PM exposure on cardiac autonomic function in young, healthy adults has received less attention. Objectives We evaluated the relationship between exposure to traffic-related PM with an aerodynamic diameter ≤ 2.5 μm (PM2.5) and HRV in a highly exposed panel of taxi drivers. Methods Continuous measurements of personal exposure to PM2.5 and ambulatory electrocardiogram monitoring were conducted on 11 young healthy taxi drivers for a 12-hr work shift during their work time (0900–2100 hr) before, during, and after the Beijing 2008 Olympic Games. Mixed-effects regression models were used to estimate associations between PM2.5 exposure and percent changes in 5-min HRV indices after combining data from the three time periods and controlling for potentially confounding variables. Results Personal exposures of taxi drivers to PM2.5 changed markedly across the three time periods. The standard deviation of normal-to-normal (SDNN) intervals decreased by 2.2% [95% confidence interval (CI), −3.8% to −0.6%] with an interquartile range (IQR; 69.5 μg/m3) increase in the 30-min PM2.5 moving average, whereas the low-frequency and high-frequency powers decreased by 4.2% (95% CI, −9.0% to 0.8%) and 6.2% (95% CI, −10.7% to −1.5%), respectively, in association with an IQR increase in the 2-hr PM2.5 moving average. Conclusions Marked changes in traffic-related PM2.5 exposure were associated with altered cardiac autonomic function in young healthy adults. PMID:20056565

  2. Drivers of Bushmeat Hunting and Perceptions of Zoonoses in Nigerian Hunting Communities

    PubMed Central

    Friant, Sagan; Paige, Sarah B.; Goldberg, Tony L.

    2015-01-01

    Bushmeat hunting threatens biodiversity and increases the risk of zoonotic pathogen transmission. Nevertheless, limited information exists on patterns of contact with wildlife in communities that practice bushmeat hunting, especially with respect to social drivers of hunting behavior. We used interview responses from hunters and non-hunters in rural hunting communities in Nigeria to: 1) quantify contact rates with wildlife, 2) identify specific hunting behaviors that increase frequency of contact, 3) identify socioeconomic factors that predispose individuals to hunt, and 4) measure perceptions of risk. Participants engaged in a variety of behaviors that increased contact with wild animals, including: butchering to sell (37%), being injured (14%), using body parts for traditional medicine (19%), collecting carcasses found in forests and/or farms (18%), and keeping as pets (16%). Hunters came into contact with wildlife significantly more than non-hunters, even through non-hunting exposure pathways. Participants reported hunting rodents (95%), ungulates (93%), carnivores (93%), primates (87%), and bats (42%), among other prey. Reported hunting frequencies within taxonomic groups of prey were different for different hunting behaviors. Young age, lower education level, larger household size, having a father who hunts, and cultural group were all associated with becoming a hunter. Fifty-five percent of respondents were aware that they could contract diseases from wild animals, but only 26% of these individuals reported taking protective measures. Overall, hunters in this setting frequently contact a diversity of prey in risky ways, and the decision to become a hunter stems from family tradition, modified by economic necessity. Conservation and public health interventions in such settings may be most efficient when they capitalize on local knowledge and target root socio-economic and cultural drivers that lead to hunting behavior. Importantly, interventions that target consumption alone will not be sufficient; other drivers and modes of interaction with wildlife must also be considered. PMID:26001078

  3. Needle versus Tube Thoracostomy in a Swine Model of Traumatic Tension Hemopneumothorax

    DTIC Science & Technology

    2009-03-01

    jugular vein, through the right atrium , and into the inferior vena cava . Serial digital C-arm chest x-rays allowed mea- surement of the shift from midline...wire in the inferior vena cava 1.34 cm to the right of the spinous processes. B: Insufflation resulted in a mediastinal shift of 2.15 cm to the left of...Received April 26, 2008, from the U.S. Army Institute of Surgical Re- search (JBH, JGM), Fort Sam Houston, Texas; the Naval Medical Cen- ter (STK), San Diego

  4. Phytoplankton dynamics in relation to seasonal variability and upwelling and relaxation patterns at the mouth of Ria de Aveiro (West Iberian Margin) over a four-year period

    PubMed Central

    Calado, António José; Moita, Maria Teresa; Cunha, Marina R.

    2017-01-01

    From June 2004 to December 2007, samples were weekly collected at a fixed station located at the mouth of Ria de Aveiro (West Iberian Margin). We examined the seasonal and inter-annual fluctuations in composition and community structure of the phytoplankton in relation to the main environmental drivers and assessed the influence of the oceanographic regime, namely changes in frequency and intensity of upwelling events, over the dynamics of the phytoplankton assemblage. The samples were consistently handled and a final subset of 136 OTUs (taxa with relative abundance > 0.01%) was subsequently submitted to various multivariate analyses. The phytoplankton assemblage showed significant changes at all temporal scales but with an overriding importance of seasonality over longer- (inter-annual) or shorter-term fluctuations (upwelling-related). Sea-surface temperature, salinity and maximum upwelling index were retrieved as the main driver of seasonal change. Seasonal signal was most evident in the fluctuations of chlorophyll a concentration and in the high turnover from the winter to spring phytoplankton assemblage. The seasonal cycle of production and succession was disturbed by upwelling events known to disrupt thermal stratification and induce changes in the phytoplankton assemblage. Our results indicate that both the frequency and intensity of physical forcing were important drivers of such variability, but the outcome in terms of species composition was highly dependent on the available local pool of species and the timing of those events in relation to the seasonal cycle. We conclude that duration, frequency and intensity of upwelling events, which vary seasonally and inter-annually, are paramount for maintaining long-term phytoplankton diversity likely by allowing unstable coexistence and incorporating species turnover at different scales. Our results contribute to the understanding of the complex mechanisms of coastal phytoplankton dynamics in relation to changing physical forcing which is fundamental to improve predictability of future prospects under climate change. PMID:28472179

  5. Phytoplankton dynamics in relation to seasonal variability and upwelling and relaxation patterns at the mouth of Ria de Aveiro (West Iberian Margin) over a four-year period.

    PubMed

    Vidal, Tânia; Calado, António José; Moita, Maria Teresa; Cunha, Marina R

    2017-01-01

    From June 2004 to December 2007, samples were weekly collected at a fixed station located at the mouth of Ria de Aveiro (West Iberian Margin). We examined the seasonal and inter-annual fluctuations in composition and community structure of the phytoplankton in relation to the main environmental drivers and assessed the influence of the oceanographic regime, namely changes in frequency and intensity of upwelling events, over the dynamics of the phytoplankton assemblage. The samples were consistently handled and a final subset of 136 OTUs (taxa with relative abundance > 0.01%) was subsequently submitted to various multivariate analyses. The phytoplankton assemblage showed significant changes at all temporal scales but with an overriding importance of seasonality over longer- (inter-annual) or shorter-term fluctuations (upwelling-related). Sea-surface temperature, salinity and maximum upwelling index were retrieved as the main driver of seasonal change. Seasonal signal was most evident in the fluctuations of chlorophyll a concentration and in the high turnover from the winter to spring phytoplankton assemblage. The seasonal cycle of production and succession was disturbed by upwelling events known to disrupt thermal stratification and induce changes in the phytoplankton assemblage. Our results indicate that both the frequency and intensity of physical forcing were important drivers of such variability, but the outcome in terms of species composition was highly dependent on the available local pool of species and the timing of those events in relation to the seasonal cycle. We conclude that duration, frequency and intensity of upwelling events, which vary seasonally and inter-annually, are paramount for maintaining long-term phytoplankton diversity likely by allowing unstable coexistence and incorporating species turnover at different scales. Our results contribute to the understanding of the complex mechanisms of coastal phytoplankton dynamics in relation to changing physical forcing which is fundamental to improve predictability of future prospects under climate change.

  6. Patient-Physician Discordance in Global Assessment in Rheumatoid Arthritis: A Systematic Literature Review With Meta-Analysis.

    PubMed

    Desthieux, Carole; Hermet, Aurore; Granger, Benjamin; Fautrel, Bruno; Gossec, Laure

    2016-12-01

    The integration of the patient in therapeutic decision-making is important in the management of rheumatoid arthritis (RA), but the patient opinion regarding disease status may differ from the physician's opinion. The aim of this study was to assess in the published literature the frequency and drivers of patient-physician discordance in global assessment in RA. A systematic literature review of all articles published up to January 2015 in Medline or Embase, reporting discordance in RA, was conducted by 2 investigators. Discordance was defined based on the absolute difference of patient global (PGA) and physician global assessments (PhGA) on 0-10-cm scales. The frequency of discordance and its predictors were collected in each study. Frequencies of discordance were pooled by meta-analysis using random effect. In all, 12 studies were selected (i.e., 11,879 patients): weighted mean ± SD age was 55.1 ± 13.9 years, weighted mean ± SD disease duration was 10.4 ± 9.3 years, and 80.7% were women. The value of the difference |PGA - PhGA| defining discordance varied between ≥0.5 cm (n = 2 studies) to ≥3 cm (n = 5 studies); the weighted mean value was 2.7 cm. The pooled percentage of patients with discordance was 43% (95% confidence interval 36%-51%; range 25%-76%). PGA was usually higher than PhGA. The drivers of PGA were pain and functional incapacity, whereas drivers of PhGA were joint counts and acute-phase reactants. Discordance in global assessment was most frequently defined as a difference of 3 points or more; even with such a stringent definition, up to half the patients were found to be discordant. The long-term consequences of this discordance remain to be determined. © 2016, American College of Rheumatology.

  7. Safety surrogate histograms (SSH): A novel real-time safety assessment of dilemma zone related conflicts at signalized intersections.

    PubMed

    Ghanipoor Machiani, Sahar; Abbas, Montasir

    2016-11-01

    Drivers' indecisiveness in dilemma zones (DZ) could result in crash-prone situations at signalized intersections. DZ is to the area ahead of an intersection in which drivers encounter a dilemma regarding whether to stop or proceed through the intersection when the signal turns yellow. An improper decision to stop by the leading driver, combined with the following driver deciding to go, can result in a rear-end collision, unless the following driver recognizes a collision is imminent and adjusts his or her behavior at or shortly after the onset of yellow. Considering the significance of DZ-related crashes, a comprehensive safety measure is needed to characterize the level of safety at signalized intersections. In this study, a novel safety surrogate measure was developed utilizing real-time radar field data. This new measure, called safety surrogate histogram (SSH), captures the degree and frequency of DZ-related conflicts at each intersection approach. SSH includes detailed information regarding the possibility of crashes, because it is calculated based on the vehicles conflicts. An example illustrating the application of the new methodology at two study sites in Virginia is presented and discussed, and a comparison is provided between SSH and other DZ-related safety surrogate measures mentioned in the literature. The results of the study reveal the efficacy of the SSH as complementary to existing surrogate measures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. The relation between working conditions, aberrant driving behaviour and crash propensity among taxi drivers in China.

    PubMed

    Wang, Yonggang; Li, Linchao; Prato, Carlo G

    2018-04-03

    Although the taxi industry is playing an important role in Chinese everyday life, little attention has been posed towards occupational health issues concerning the taxi drivers' working conditions, driving behaviour and road safety. A cross-sectional survey was administered to 1021 taxi drivers from 21 companies in four Chinese cities and collected information about (i) sociodemographic characteristics, (ii) working conditions, (iii) frequency of daily aberrant driving behaviour, and (iv) involvement in property-damage-only (PDO) and personal injury (PI) crashes over the past two years. A hybrid bivariate model of crash involvement was specified: (i) the hybrid part concerned a latent variable model capturing unobserved traits of the taxi drivers; (ii) the bivariate part modelled jointly both types of crashes while capturing unobserved correlation between error terms. The survey answers paint a gloomy picture in terms of workload, as taxi drivers reported averages of 9.4 working hours per day and 6.7 working days per week that amount on average to about 63.0 working hours per week. Moreover, the estimates of the hybrid bivariate model reveal that increasing levels of fatigue, reckless behaviour and aggressive behaviour are positively related to a higher propensity of crash involvement. Lastly, the heavy workload is also positively correlated with the higher propensity of crashing, not only directly as a predictor of crash involvement, but also indirectly as a covariate of fatigue and aberrant driving behaviour. The findings from this study provide insights into potential strategies for preventive education and taxi industry management to improve the working conditions and hence reduce fatigue and road risk for the taxi drivers. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Development of a dual-pulse RF driver for an S-band (= 2856 MHz) RF electron linear accelerator

    NASA Astrophysics Data System (ADS)

    Cha, Sungsu; Kim, Yujong; Lee, Byeong-No; Lee, Byung Cheol; Cha, Hyungki; Ha, Jang Ho; Park, Hyung Dal; Lee, Seung Hyun; Kim, Hui Su; Buaphad, Pikad

    2016-04-01

    The radiation equipment research division of Korea Atomic Energy Research Institute has developed a Container Inspection System (CIS) using a Radio Frequency (RF) electron linear accelerator for port security. The primary purpose of the CIS is to detect nuclear materials and explosives, as well country-specific prohibited substances, e.g., smuggled. The CIS consists of a 9/6 MeV dualenergy electron linear accelerator for distinguishing between organic and inorganic materials. The accelerator consists of an electron gun, an RF accelerating structure, an RF driver, a modulator, electromagnets, a cooling system, a X-ray generating target, X-ray collimator, a detector, and a container moving system. The RF driver is an important part of the configuration because it is the RF power source: it supplies the RF power to the accelerating structure. A unique aspect of the RF driver is that it generates dual RF power to generate dual energy (9/6 MeV). The advantage of this RF driver is that it can allow the pulse width to vary and can be used to obtain a wide range of energy output, and pulse repetition rates up to 300 Hz. For this reason, 140 W (5 MW - 9 MeV) and 37 W (3.4 MW - 6 MeV) power outputs are available independently. A high power test for 20 minutes demonstrate that stable dual output powers can be generated. Moreover, the dual power can be applied to the accelerator which has stable accelerator operation. In this paper, the design, fabrication and high power test of the RF driver for the RF electron linear accelerator (linac) are presented.

  10. Characteristics of On-Road Driving Performance of Persons With Central Vision Loss Who Use Bioptic Telescopes

    PubMed Central

    Wood, Joanne M.; McGwin, Gerald; Elgin, Jennifer; Searcey, Karen; Owsley, Cynthia

    2013-01-01

    Purpose. To compare the on-road driving performance of visually impaired drivers using bioptic telescopes with age-matched controls. Methods. Participants included 23 persons (mean age = 33 ± 12 years) with visual acuity of 20/63 to 20/200 who were legally licensed to drive through a state bioptic driving program, and 23 visually normal age-matched controls (mean age = 33 ± 12 years). On-road driving was assessed in an instrumented dual-brake vehicle along 14.6 miles of city, suburban, and controlled-access highways. Two backseat evaluators independently rated driving performance using a standardized scoring system. Vehicle control was assessed through vehicle instrumentation and video recordings used to evaluate head movements, lane-keeping, pedestrian detection, and frequency of bioptic telescope use. Results. Ninety-six percent (22/23) of bioptic drivers and 100% (23/23) of controls were rated as safe to drive by the evaluators. There were no group differences for pedestrian detection, or ratings for scanning, speed, gap judgments, braking, indicator use, or obeying signs/signals. Bioptic drivers received worse ratings than controls for lane position and steering steadiness and had lower rates of correct sign and traffic signal recognition. Bioptic drivers made significantly more right head movements, drove more often over the right-hand lane marking, and exhibited more sudden braking than controls. Conclusions. Drivers with central vision loss who are licensed to drive through a bioptic driving program can display proficient on-road driving skills. This raises questions regarding the validity of denying such drivers a license without the opportunity to train with a bioptic telescope and undergo on-road evaluation. PMID:23640044

  11. Flood events across the North Atlantic region - past development and future perspectives

    NASA Astrophysics Data System (ADS)

    Matti, Bettina; Dieppois, Bastien; Lawler, Damian; Dahlke, Helen E.; Lyon, Steve W.

    2016-04-01

    Flood events have a large impact on humans, both socially and economically. An increase in winter and spring flooding across much of northern Europe in recent years opened up the question of changing underlying hydro-climatic drivers of flood events. Predicting the manifestation of such changes is difficult due to the natural variability and fluctuations in northern hydrological systems caused by large-scale atmospheric circulations, especially under altered climate conditions. Improving knowledge on the complexity of these hydrological systems and their interactions with climate is essential to be able to determine drivers of flood events and to predict changes in these drivers under altered climate conditions. This is particularly true for the North Atlantic region where both physical catchment properties and large-scale atmospheric circulations have a profound influence on floods. This study explores changes in streamflow across North Atlantic region catchments. An emphasis is placed on high-flow events, namely the timing and magnitude of past flood events, and selected flood percentiles were tested for stationarity by applying a flood frequency analysis. The issue of non-stationarity of flood return periods is important when linking streamflow to large-scale atmospheric circulations. Natural fluctuations in these circulations are found to have a strong influence on the outcome causing natural variability in streamflow records. Long time series and a multi-temporal approach allows for determining drivers of floods and linking streamflow to large-scale atmospheric circulations. Exploring changes in selected hydrological signatures consistency was found across much of the North Atlantic region suggesting a shift in flow regime. The lack of an overall regional pattern suggests that how catchments respond to changes in climatic drivers is strongly influenced by their physical characteristics. A better understanding of hydrological response to climate drivers is essential for example for forecasting purposes.

  12. The effects of texting on driving performance in a driving simulator: the influence of driver age.

    PubMed

    Rumschlag, Gordon; Palumbo, Theresa; Martin, Amber; Head, Doreen; George, Rajiv; Commissaris, Randall L

    2015-01-01

    Distracted driving is a significant contributor to motor vehicle accidents and fatalities, and texting is a particularly significant form of driver distraction that continues to be on the rise. The present study examined the influence of driver age (18-59 years old) and other factors on the disruptive effects of texting on simulated driving behavior. While 'driving' the simulator, subjects were engaged in a series of brief text conversations with a member of the research team. The primary dependent variable was the occurrence of Lane Excursions (defined as any time the center of the vehicle moved outside the directed driving lane, e.g., into the lane for oncoming traffic or onto the shoulder of the road), measured as (1) the percent of subjects that exhibited Lane Excursions, (2) the number of Lane Excursions occurring and (3) the percent of the texting time in Lane Excursions. Multiple Regression analyses were used to assess the influence of several factors on driving performance while texting, including text task duration, texting skill level (subject-reported), texting history (#texts/week), driver gender and driver age. Lane Excursions were not observed in the absence of texting, but 66% of subjects overall exhibited Lane Excursions while texting. Multiple Regression analysis for all subjects (N=50) revealed that text task duration was significantly correlated with the number of Lane Excursions, and texting skill level and driver age were significantly correlated with the percent of subjects exhibiting Lane Excursions. Driver gender was not significantly correlated with Lane Excursions during texting. Multiple Regression analysis of only highly skilled texters (N=27) revealed that driver age was significantly correlated with the number of Lane Excursions, the percent of subjects exhibiting Lane Excursions and the percent of texting time in Lane Excursions. In contrast, Multiple Regression analysis of those drivers who self-identified as not highly skilled texters (N=23) revealed that text task duration was significantly correlated with the number of Lane Excursions. The present studies confirm past reports that texting impairs driving simulator performance. Moreover, the present study demonstrates that for highly skilled texters, the effects of texting on driving are actually worse for older drivers. Given the increasing frequency of texting while driving within virtually all age groups, these data suggest that 'no texting while driving' education and public service messages need to be continued, and they should be expanded to target older drivers as well. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Frequency of Sexual Activity With Most Recent Male Partner Among Young, Internet-Using Men Who Have Sex With Men in the United States

    PubMed Central

    WALL, KRISTIN M.; STEPHENSON, ROBERT; SULLIVAN, PATRICK S.

    2015-01-01

    Sex frequency, defined here as the number of oral or anal sex acts with the most recent partner in the past year, is a potential driver of risk for sexually transmitted infections. However, few data on sex frequency have been reported for men who have sex with men (MSM). Data from an Internet survey of MSM were used to describe sex frequency with most recent main and casual male partners and to estimate factors associated with higher sex frequency. Among 5,193 MSM, higher sex frequency was associated with younger age, shorter relationship duration, and reporting a main (vs. casual) partner; and lower sex frequency with male partners was associated with heterosexual or bisexual (vs. homosexual) identity or Black race (vs. non-Hispanic White). Secondary analyses of estimates of sex frequency from 2 publicly available nationally representative datasets comprised of primarily heterosexual survey respondents (the 2008 General Social Survey and the 1992 National Health and Social Life Survey) were performed. Sex frequency among MSM respondents was similar to that reported by heterosexuals. PMID:24059971

  14. Sleepiness and Motor Vehicle Crashes in a Representative Sample of Portuguese Drivers: The Importance of Epidemiological Representative Surveys.

    PubMed

    Gonçalves, M; Peralta, A R; Monteiro Ferreira, J; Guilleminault, Christian

    2015-01-01

    Sleepiness is considered to be a leading cause of crashes. Despite the huge amount of information collected in questionnaire studies, only some are based on representative samples of the population. Specifics of the populations studied hinder the generalization of these previous findings. For the Portuguese population, data from sleep-related car crashes/near misses and sleepiness while driving are missing. The objective of this study is to determine the prevalence of near-miss and nonfatal motor vehicle crashes related to sleepiness in a representative sample of Portuguese drivers. Structured phone interviews regarding sleepiness and sleep-related crashes and near misses, driving habits, demographic data, and sleep quality were conducted using the Pittsburgh Sleep Quality Index and sleep apnea risk using the Berlin questionnaire. A multivariate regression analysis was used to determine the associations with sleepy driving (feeling sleepy or falling asleep while driving) and sleep-related near misses and crashes. Nine hundred subjects, representing the Portuguese population of drivers, were included; 3.1% acknowledged falling asleep while driving during the previous year and 0.67% recalled sleepiness-related crashes. Higher education, driving more than 15,000 km/year, driving more frequently between 12:00 a.m. and 6 a.m., fewer years of having a driver's license, less total sleep time per night, and higher scores on the Epworth Sleepiness Scale (ESS) were all independently associated with sleepy driving. Sleepiness-related crashes and near misses were associated only with falling asleep at the wheel in the previous year. Sleep-related crashes occurred more frequently in drivers who had also had sleep-related near misses. Portugal has lower self-reported sleepiness at the wheel and sleep-related near misses than most other countries where epidemiological data are available. Different population characteristics and cultural, social, and road safety specificities may be involved in these discrepancies. Despite this, Portuguese drivers report sleep-related crashes in frequencies similar to those of drivers in other countries.

  15. Brake reactions of distracted drivers to pedestrian Forward Collision Warning systems.

    PubMed

    Lubbe, Nils

    2017-06-01

    Forward Collision Warning (FCW) can be effective in directing driver attention towards a conflict and thereby aid in preventing or mitigating collisions. FCW systems aiming at pedestrian protection have been introduced onto the market, yet an assessment of their safety benefits depends on the accurate modeling of driver reactions when the system is activated. This study contributes by quantifying brake reaction time and brake behavior (deceleration levels and jerk) to compare the effectiveness of an audio-visual warning only, an added haptic brake pulse warning, and an added Head-Up Display in reducing the frequency of collisions with pedestrians. Further, this study provides a detailed data set suited for the design of assessment methods for car-to-pedestrian FCW systems. Brake response characteristics were measured for heavily distracted drivers who were subjected to a single FCW event in a high-fidelity driving simulator. The drivers maintained a self-regulated speed of 30km/h in an urban area, with gaze direction diverted from the forward roadway by a secondary task. Collision rates and brake reaction times differed significantly across FCW settings. Brake pulse warnings resulted in the lowest number of collisions and the shortest brake reaction times (mean 0.8s, SD 0.29s). Brake jerk and deceleration were independent of warning type. Ninety percent of drivers exceeded a maximum deceleration of 3.6m/s 2 and a jerk of 5.3m/s 3 . Brake pulse warning was the most effective FCW interface for preventing collisions. In addition, this study presents the data required for driver modeling for car-to-pedestrian FCW similar to Euro NCAP's 2015 car-to-car FCW assessment. Practical applications: Vehicle manufacturers should consider the introduction of brake pulse warnings to their FCW systems. Euro NCAP could introduce an assessment that quantifies the safety benefits of pedestrian FCW systems and thereby aid the proliferation of effective systems. Copyright © 2017 National Safety Council and Elsevier Ltd. All rights reserved.

  16. Modeling crash injury severity by road feature to improve safety.

    PubMed

    Penmetsa, Praveena; Pulugurtha, Srinivas S

    2018-01-02

    The objective of this research is 2-fold: to (a) model and identify critical road features (or locations) based on crash injury severity and compare it with crash frequency and (b) model and identify drivers who are more likely to contribute to crashes by road feature. Crash data from 2011 to 2013 were obtained from the Highway Safety Information System (HSIS) for the state of North Carolina. Twenty-three different road features were considered, analyzed, and compared with each other as well as no road feature. A multinomial logit (MNL) model was developed and odds ratios were estimated to investigate the effect of road features on crash injury severity. Among the many road features, underpass, end or beginning of a divided highway, and on-ramp terminal on crossroad are the top 3 critical road features. Intersection crashes are frequent but are not highly likely to result in severe injuries compared to critical road features. Roundabouts are least likely to result in both severe and moderate injuries. Female drivers are more likely to be involved in crashes at intersections (4-way and T) compared to male drivers. Adult drivers are more likely to be involved in crashes at underpasses. Older drivers are 1.6 times more likely to be involved in a crash at the end or beginning of a divided highway. The findings from this research help to identify critical road features that need to be given priority. As an example, additional advanced warning signs and providing enlarged or highly retroreflective signs that grab the attention of older drivers may help in making locations such as end or beginning of a divided highway much safer. Educating drivers about the necessary skill sets required at critical road features in addition to engineering solutions may further help them adopt safe driving behaviors on the road.

  17. Sleep-related car crashes: risk perception and decision-making processes in young drivers.

    PubMed

    Lucidi, Fabio; Russo, Paolo Maria; Mallia, Luca; Devoto, Alessandra; Lauriola, Marco; Violani, Cristiano

    2006-03-01

    The aim of the present study is to analyse factors affecting worries, coping strategies and decisions of young drivers regarding the risk of sleep-related car crashes. Furthermore, the study also analyses whether framing the same information about sleepiness in two different linguistic forms influences: (1) the evaluation of the level of risk associated to a specific level of drowsiness (Attribute Framing problem); (2) the willingness to enact strategies to "prevent" sleepiness before night-time driving (Goal Framing problem); (3) the choice between two different ways, both of equal expected efficacy, of lowering drowsiness (Risky decision-making Framing problem). Six hundred and ninety-five young drivers [(57.6% females, 42.4% males); mean age 20.85 years (S.D.=1.2)] answered questions on drive risk perception and sleepiness, on nocturnal driving experience and on the strategies to deal with driver sleepiness, responding to one of the two different versions of the framed problems. A sub-sample of 130 participants completed the framed problems in both versions. The results show that experiences of sleep attacks and nocturnal driving frequency in the past 6 months affect both risk perception and the preventive strategies adopted. Furthermore, the manipulation on two out of the three problems (attribute and risky decision-making frames) significantly affected the respondents' evaluation.

  18. Experimental Investigation of Unsteady Thrust Augmentation Using a Speaker-Driven Jet

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.; Wernet, Mark P.; John, Wentworth T.

    2007-01-01

    An experimental investigation is described in which a simple speaker-driven jet was used as a pulsed thrust source (driver) for an ejector configuration. The objectives of the investigation were twofold. The first was to expand the experimental body of evidence showing that an unsteady thrust source, combined with a properly sized ejector generally yields higher thrust augmentation values than a similarly sized, steady driver of equivalent thrust. The second objective was to identify characteristics of the unsteady driver that may be useful for sizing ejectors, and for predicting the thrust augmentation levels that may be achieved. The speaker-driven jet provided a convenient source for the investigation because it is entirely unsteady (i.e., it has no mean velocity component) and because relevant parameters such as frequency, time-averaged thrust, and diameter are easily variable. The experimental setup will be described, as will the two main measurements techniques employed. These are thrust and digital particle imaging velocimetry of the driver. It will be shown that thrust augmentation values as high as 1.8 were obtained, that the diameter of the best ejector scaled with the dimensions of the emitted vortex, and that the so-called formation time serves as a useful dimensionless parameter by which to characterize the jet and predict performance.

  19. Drivers' decision-making when attempting to cross an intersection results from choice between affordances

    PubMed Central

    Marti, Geoffrey; Morice, Antoine H. P.; Montagne, Gilles

    2015-01-01

    In theory, a safe approach to an intersection implies that drivers can simultaneously manage two scenarios: they either choose to cross or to give way to an oncoming vehicle. In this article we formalize the critical time for safe crossing (CTcross) and the critical time for safe stopping (CTstop) to represent crossing and stopping possibilities, respectively. We describe these critical times in terms of affordances and empirically test their respective contribution to the driver's decision-making process. Using a driving simulator, three groups of participants drove cars with identical acceleration capabilities and different braking capabilities. They were asked to try to cross an intersection where there was an oncoming vehicle, if they deemed the maneuver to be safe. If not, they could decide to stop or, as a last resort, make an emergency exit. The intersections were identical among groups. Results showed that although the crossing possibilities (CTcross) were the same for all groups, there were between-group differences in crossing frequency. This suggests that stopping possibilities (CTstop) play a role in the driver's decision-making process, in addition to the crossing possibilities. These results can be accounted for by a behavioral model of decision making, and provide support for the hypothesis of choice between affordances. PMID:25620922

  20. Emergence of increased frequency and severity of multiple infections by viruses due to spatial clustering of hosts

    NASA Astrophysics Data System (ADS)

    Taylor, Bradford P.; Penington, Catherine J.; Weitz, Joshua S.

    2016-12-01

    Multiple virus particles can infect a target host cell. Such multiple infections (MIs) have significant and varied ecological and evolutionary consequences for both virus and host populations. Yet, the in situ rates and drivers of MIs in virus-microbe systems remain largely unknown. Here, we develop an individual-based model (IBM) of virus-microbe dynamics to probe how spatial interactions drive the frequency and nature of MIs. In our IBMs, we identify increasingly spatially correlated clusters of viruses given sufficient decreases in viral movement. We also identify increasingly spatially correlated clusters of viruses and clusters of hosts given sufficient increases in viral infectivity. The emergence of clusters is associated with an increase in multiply infected hosts as compared to expectations from an analogous mean field model. We also observe long-tails in the distribution of the multiplicity of infection in contrast to mean field expectations that such events are exponentially rare. We show that increases in both the frequency and severity of MIs occur when viruses invade a cluster of uninfected microbes. We contend that population-scale enhancement of MI arises from an aggregate of invasion dynamics over a distribution of microbe cluster sizes. Our work highlights the need to consider spatially explicit interactions as a potentially key driver underlying the ecology and evolution of virus-microbe communities.

Top