Chuian, O M; Biriukova, O O; Ravaieva, M Iu
2010-01-01
We studied the changes in indexes of variability of heart rate and fractal neurodynamics under conditions of controlled breathing on fluctuation frequency of a spectrum of heart rate. It is shown that the controlled breathing, which frequency corresponds to a frequency of localization of the maximum peak of capacity ofa heart rate in low-frequency is a powerful mechanism of management of heart rate and change of a functional condition of an organism as a whole.
Suzuki, T; Okamura, K; Kimura, Y; Watanabe, T; Yaegashi, N; Murotsuki, J; Uehara, S; Yajima, A
2000-05-01
The appearance of the sinusoidal heart rate pattern found on fetal cardiotocograms has not been fully explained, either physiologically or clinically. In this study we performed power spectral analysis on the sinusoidal heart rate pattern obtained by administration of arginine vasopressin and atropine sulfate to investigate its frequency components in fetal lambs with long-term instrument implantation. Eleven tests were performed in 4 fetal lambs at 120 to 130 days' gestation. An artificial sinusoidal heart rate pattern was obtained by administration of atropine sulfate and arginine vasopressin in 9 tests. An autoregression model was used to compare the spectral patterns before and during the sinusoidal heart rate pattern. Marked decreases in low-frequency (0.025-0.125 cycles/beat) and high-frequency (0.2-0.5 cycles/beat) areas were observed in the presence of the sinusoidal heart rate pattern. However, there were no significant changes in the very-low-frequency area (0.01-0.025 cycles/beat), which corresponds to the frequency of the sinusoidal heart rate pattern. The sinusoidal heart rate pattern may represent a very low-frequency component inherent in fetal heart rate variability that appears when low- and high-frequency components are reduced as a result of strongly suppressed autonomic nervous activity.
Gender- and age-related differences in heart rate dynamics: are women more complex than men?
NASA Technical Reports Server (NTRS)
Ryan, S. M.; Goldberger, A. L.; Pincus, S. M.; Mietus, J.; Lipsitz, L. A.
1994-01-01
OBJECTIVES. This study aimed to quantify the complex dynamics of beat-to-beat sinus rhythm heart rate fluctuations and to determine their differences as a function of gender and age. BACKGROUND. Recently, measures of heart rate variability and the nonlinear "complexity" of heart rate dynamics have been used as indicators of cardiovascular health. Because women have lower cardiovascular risk and greater longevity than men, we postulated that there are important gender-related differences in beat-to-beat heart rate dynamics. METHODS. We analyzed heart rate dynamics during 8-min segments of continuous electrocardiographic recording in healthy young (20 to 39 years old), middle-aged (40 to 64 years old) and elderly (65 to 90 years old) men (n = 40) and women (n = 27) while they performed spontaneous and metronomic (15 breaths/min) breathing. Relatively high (0.15 to 0.40 Hz) and low (0.01 to 0.15 Hz) frequency components of heart rate variability were computed using spectral analysis. The overall "complexity" of each heart rate time series was quantified by its approximate entropy, a measure of regularity derived from nonlinear dynamics ("chaos" theory). RESULTS. Mean heart rate did not differ between the age groups or genders. High frequency heart rate power and the high/low frequency power ratio decreased with age in both men and women (p < 0.05). The high/low frequency power ratio during spontaneous and metronomic breathing was greater in women than men (p < 0.05). Heart rate approximate entropy decreased with age and was higher in women than men (p < 0.05). CONCLUSIONS. High frequency heart rate spectral power (associated with parasympathetic activity) and the overall complexity of heart rate dynamics are higher in women than men. These complementary findings indicate the need to account for gender-as well as age-related differences in heart rate dynamics. Whether these gender differences are related to lower cardiovascular disease risk and greater longevity in women requires further study.
Scully, Christopher G; Selvaraj, Nandakumar; Romberg, Frederick W; Wardhan, Richa; Ryan, John; Florian, John P; Silverman, David G; Shelley, Kirk H; Chon, Ki H
2012-07-01
We designed this study to determine if 900 mL of blood withdrawal during spontaneous breathing in healthy volunteers could be detected by examining the time-varying spectral amplitude of the photoplethysmographic (PPG) waveform in the heart rate frequency band and/or in the breathing rate frequency band before significant changes occurred in heart rate or arterial blood pressure. We also identified the best PPG probe site for early detection of blood volume loss by testing ear, finger, and forehead sites. Eight subjects had 900 mL of blood withdrawn followed by reinfusion of 900 mL of blood. Physiological monitoring included PPG waveforms from ear, finger, and forehead probe sites, standard electrocardiogram, and standard blood pressure cuff measurements. The time-varying amplitude sequences in the heart rate frequency band and breathing rate frequency band present in the PPG waveform were extracted from high-resolution time-frequency spectra. These amplitudes were used as a parameter for blood loss detection. Heart rate and arterial blood pressure did not significantly change during the protocol. Using time-frequency analysis of the PPG waveform from ear, finger, and forehead probe sites, the amplitude signal extracted at the frequency corresponding to the heart rate significantly decreased when 900 mL of blood was withdrawn, relative to baseline (all P < 0.05); for the ear, the corresponding signal decreased when only 300 mL of blood was withdrawn. The mean percent decrease in the amplitude of the heart rate component at 900 mL blood loss relative to baseline was 45.2% (38.2%), 42.0% (29.2%), and 42.3% (30.5%) for ear, finger, and forehead probe sites, respectively, with the lower 95% confidence limit shown in parentheses. After 900 mL blood reinfusion, the amplitude signal at the heart rate frequency showed a recovery towards baseline. There was a clear separation of amplitude values at the heart rate frequency between baseline and 900 mL blood withdrawal. Specificity and sensitivity were both found to be 87.5% with 95% confidence intervals (47.4%, 99.7%) for ear PPG signals for a chosen threshold value that was optimized to separate the 2 clusters of amplitude values (baseline and blood loss) at the heart rate frequency. Meanwhile, no significant changes in the spectral amplitude in the frequency band corresponding to respiration were found. A time-frequency spectral method detected blood loss in spontaneously breathing subjects before the onset of significant changes in heart rate or blood pressure. Spectral amplitudes at the heart rate frequency band were found to significantly decrease during blood loss in spontaneously breathing subjects, whereas those at the breathing rate frequency band did not significantly change. This technique may serve as a valuable tool in intraoperative and trauma settings to detect and monitor hemorrhage.
Voluntary control of breathing does not alter vagal modulation of heart rate
NASA Technical Reports Server (NTRS)
Patwardhan, A. R.; Evans, J. M.; Bruce, E. N.; Eckberg, D. L.; Knapp, C. F.
1995-01-01
Variations in respiratory pattern influence the heart rate spectrum. It has been suggested, hence, that metronomic respiration should be used to correctly assess vagal modulation of heart rate by using spectral analysis. On the other hand, breathing to a metronome has been reported to increase heart rate spectral power in the high- or respiratory frequency region; this finding has led to the suggestion that metronomic respiration enhances vagal tone or alters vagal modulation of heart rate. To investigate whether metronomic breathing complicates the interpretation of heart rate spectra by altering vagal modulation, we recorded the electrocardiogram and respiration from eight volunteers during three breathing trials of 10 min each: 1) spontaneous breathing (mean rate of 14.4 breaths/min); 2) breathing to a metronome at the rate of 15, 18, and 21 breaths/min for 2, 6, and 2 min, respectively; and 3) breathing to a metronome at the rate of 18 breaths/min for 10 min. Data were also collected from eight volunteers who breathed spontaneously for 20 min and breathed metronomically at each subject's mean spontaneous breathing frequency for 20 min. Results from the three 10-min breathing trials showed that heart rate power in the respiratory frequency region was smaller during metronomic breathing than during spontaneous breathing. This decrease could be explained fully by the higher breathing frequencies used during trials 2 and 3 of metronomic breathing. When the subjects breathed metronomically at each subject's mean breathing frequency, the heart rate powers during metronomic breathing were similar to those during spontaneous breathing. Our results suggest that vagal modulation of heart rate is not altered and vagal tone is not enhanced during metronomic breathing.
Influence of ECG sampling rate in fetal heart rate variability analysis.
De Jonckheere, J; Garabedian, C; Charlier, P; Champion, C; Servan-Schreiber, E; Storme, L; Debarge, V; Jeanne, M; Logier, R
2017-07-01
Fetal hypoxia results in a fetal blood acidosis (pH<;7.10). In such a situation, the fetus develops several adaptation mechanisms regulated by the autonomic nervous system. Many studies demonstrated significant changes in heart rate variability in hypoxic fetuses. So, fetal heart rate variability analysis could be of precious help for fetal hypoxia prediction. Commonly used fetal heart rate variability analysis methods have been shown to be sensitive to the ECG signal sampling rate. Indeed, a low sampling rate could induce variability in the heart beat detection which will alter the heart rate variability estimation. In this paper, we introduce an original fetal heart rate variability analysis method. We hypothesize that this method will be less sensitive to ECG sampling frequency changes than common heart rate variability analysis methods. We then compared the results of this new heart rate variability analysis method with two different sampling frequencies (250-1000 Hz).
Heart rate and respiratory rhythm dynamics on ascent to high altitude.
Lipsitz, L. A.; Hashimoto, F.; Lubowsky, L. P.; Mietus, J.; Moody, G. B.; Appenzeller, O.; Goldberger, A. L.
1995-01-01
OBJECTIVE--To investigate the alterations in autonomic control of heart rate at high altitude and to test the hypothesis that hypoxaemic stress during exposure to high altitude induces non-linear, periodic heart rate oscillations, similar to those seen in heart failure and the sleep apnoea syndrome. SUBJECTS--11 healthy subjects aged 24-64. MAIN OUTCOME MEASURES--24 hour ambulatory electrocardiogram records obtained at baseline (1524 m) and at 4700 m. Simultaneous heart rate and respiratory dynamics during 2.5 hours of sleep by fast Fourier transform analysis of beat to beat heart rate and of an electrocardiographically derived respiration signal. RESULTS--All subjects had resting hypoxaemia at high altitude, with an average oxyhaemoglobin saturation of 81% (5%). There was no significant change in mean heart rate, but low frequency (0.01-0.05 Hz) spectral power was increased (P < 0.01) at high altitude. Time series analysis showed a complex range of non-linear sinus rhythm dynamics. Striking low frequency (0.04-0.06 Hz) heart rate oscillations were observed during sleep in eight subjects at high altitude. Analysis of the electrocardiographically derived respiration signal indicated that these heart rate oscillations correlated with low frequency respiratory oscillations. CONCLUSIONS--These data suggest (a) that increased low frequency power during high altitude exposure is not simply attributable to increased sympathetic modulation of heart rate, but relates to distinctive cardiopulmonary oscillations at approximately 0.05 Hz and (b) that the emergence of periodic heart rate oscillations at high altitude is consistent with an unstable cardiopulmonary control system that may develop on acute exposure to hypoxaemic stress. PMID:7488453
Heart rate and respiratory rhythm dynamics on ascent to high altitude
NASA Technical Reports Server (NTRS)
Lipsitz, L. A.; Hashimoto, F.; Lubowsky, L. P.; Mietus, J.; Moody, G. B.; Appenzeller, O.; Goldberger, A. L.
1995-01-01
OBJECTIVE--To investigate the alterations in autonomic control of heart rate at high altitude and to test the hypothesis that hypoxaemic stress during exposure to high altitude induces non-linear, periodic heart rate oscillations, similar to those seen in heart failure and the sleep apnoea syndrome. SUBJECTS--11 healthy subjects aged 24-64. MAIN OUTCOME MEASURES--24 hour ambulatory electrocardiogram records obtained at baseline (1524 m) and at 4700 m. Simultaneous heart rate and respiratory dynamics during 2.5 hours of sleep by fast Fourier transform analysis of beat to beat heart rate and of an electrocardiographically derived respiration signal. RESULTS--All subjects had resting hypoxaemia at high altitude, with an average oxyhaemoglobin saturation of 81% (5%). There was no significant change in mean heart rate, but low frequency (0.01-0.05 Hz) spectral power was increased (P < 0.01) at high altitude. Time series analysis showed a complex range of non-linear sinus rhythm dynamics. Striking low frequency (0.04-0.06 Hz) heart rate oscillations were observed during sleep in eight subjects at high altitude. Analysis of the electrocardiographically derived respiration signal indicated that these heart rate oscillations correlated with low frequency respiratory oscillations. CONCLUSIONS--These data suggest (a) that increased low frequency power during high altitude exposure is not simply attributable to increased sympathetic modulation of heart rate, but relates to distinctive cardiopulmonary oscillations at approximately 0.05 Hz and (b) that the emergence of periodic heart rate oscillations at high altitude is consistent with an unstable cardiopulmonary control system that may develop on acute exposure to hypoxaemic stress.
Spectral indices of cardiovascular adaptations to short-term simulated microgravity exposure
NASA Technical Reports Server (NTRS)
Patwardhan, A. R.; Evans, J. M.; Berk, M.; Grande, K. J.; Charles, J. B.; Knapp, C. F.
1995-01-01
We investigated the effects of exposure to microgravity on the baseline autonomic balance in cardiovascular regulation using spectral analysis of cardiovascular variables measured during supine rest. Heart rate, arterial pressure, radial flow, thoracic fluid impedance and central venous pressure were recorded from nine volunteers before and after simulated microgravity, produced by 20 hours of 6 degrees head down bedrest plus furosemide. Spectral powers increased after simulated microgravity in the low frequency region (centered at about 0.03 Hz) in arterial pressure, heart rate and radial flow, and decreased in the respiratory frequency region (centered at about 0.25 Hz) in heart rate. Reduced heart rate power in the respiratory frequency region indicates reduced parasympathetic influence on the heart. A concurrent increase in the low frequency power in arterial pressure, heart rate, and radial flow indicates increased sympathetic influence. These results suggest that the baseline autonomic balance in cardiovascular regulation is shifted towards increased sympathetic and decreased parasympathetic influence after exposure to short-term simulated microgravity.
High-frequency autonomic modulation: a new model for analysis of autonomic cardiac control.
Champéroux, Pascal; Fesler, Pierre; Judé, Sebastien; Richard, Serge; Le Guennec, Jean-Yves; Thireau, Jérôme
2018-05-03
Increase in high-frequency beat-to-beat heart rate oscillations by torsadogenic hERG blockers appears to be associated with signs of parasympathetic and sympathetic co-activation which cannot be assessed directly using classic methods of heart rate variability analysis. The present work aimed to find a translational model that would allow this particular state of the autonomic control of heart rate to be assessed. High-frequency heart rate and heart period oscillations were analysed within discrete 10 s intervals in a cohort of 200 healthy human subjects. Results were compared to data collected in non-human primates and beagle dogs during pharmacological challenges and torsadogenic hERG blockers exposure, in 127 genotyped LQT1 patients on/off β-blocker treatment and in subgroups of smoking and non-smoking subjects. Three states of autonomic modulation, S1 (parasympathetic predominance) to S3 (reciprocal parasympathetic withdrawal/sympathetic activation), were differentiated to build a new model of heart rate variability referred to as high-frequency autonomic modulation. The S2 state corresponded to a specific state during which both parasympathetic and sympathetic systems were coexisting or co-activated. S2 oscillations were proportionally increased by torsadogenic hERG-blocking drugs, whereas smoking caused an increase in S3 oscillations. The combined analysis of the magnitude of high-frequency heart rate and high-frequency heart period oscillations allows a refined assessment of heart rate autonomic modulation applicable to long-term ECG recordings and offers new approaches to assessment of the risk of sudden death both in terms of underlying mechanisms and sensitivity. © 2018 The Authors. British Journal of Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.
Heart rate variability alterations in late life depression: A meta-analysis.
Brown, Lydia; Karmakar, Chandan; Gray, Richard; Jindal, Ripu; Lim, Terrence; Bryant, Christina
2018-08-01
There is strong evidence for a bi-directional relationship between heart-health and depression in later life, but the physiological mechanisms underlying this relationship remain unclear. Heart rate variability is one promising factor that might help explain this relationship. We present results of a meta-analysis that considers heart rate variability alterations in older adults with depression. Literature search of Embase, PsychInfo and Medline revealed five clinical studies and six observational studies that examined the relationship between heart rate variability and depression in adults with a mean age over 60. These studies were included in this meta-analysis. Heart rate variability was reduced among older adults with clinical depression (N = 550), relative to healthy controls (Hedges' g = -0.334, 95%CI [-0.579, -0.090], p = .007). When high-frequency and low-frequency heart rate variability were investigated separately, only low-frequency heart rate variability was significantly reduced in depressed patients (Hedges' g = -0.626, 95%CI [-1.083, -0.169], p = .007). A similar but weaker pattern of results was found in the observational studies. Most findings remained significant among unmedicated depressed older adults. Evidence of effect-size heterogeneity was found in the clinical studies, indicating the need for more well-designed research in the area. Heart rate variability is reduced among older adults with depression, and this effect is not fully attributable to antidepressant medication use. Specifically, low-frequency heart rate variability may be reduced in depressed older adults. Heart rate variability warrants further attention, as it could help inform research into the prevention and treatment of depression in later life. Copyright © 2018 Elsevier B.V. All rights reserved.
Conelea, Christine A.; Ramanujam, Krishnapriya; Walther, Michael R.; Freeman, Jennifer B.; Garcia, Abbe M.
2014-01-01
Stress is the contextual variable most commonly implicated in tic exacerbations. However, research examining associations between tics, stressors, and the biological stress response has yielded mixed results. This study examined whether tics occur at a greater frequency during discrete periods of heightened physiological arousal. Children with co-occurring tic and anxiety disorders (n = 8) completed two stress induction tasks (discussion of family conflict, public speech). Observational (tic frequencies) and physiological (heart rate) data were synchronized using The Observer XT, and tic frequencies were compared across periods of high and low heart rate. Tic frequencies across the entire experiment did not increase during periods of higher heart rate. During the speech task, tic frequencies were significantly lower during periods of higher heart rate. Results suggest that tic exacerbations may not be associated with heightened physiological arousal and highlight the need for further tic research using integrated measurement of behavioral and biological processes. PMID:24662238
Short-term variability of blood pressure and heart rate in hyperthyroidism.
Girard, A; Hugues, F C; Le Jeunne, C; Elghozi, J L
1998-06-01
The effect of hyperthyroidism on the short-term memory variability of blood pressure and heart rate was evaluated in 12 untreated hyperthyroid patients during thyrotoxicosis and after a 6 1/2 month treatment designed to achieve a stable euthyroid state. Beat-by-beat finger blood pressure was measured with a Finapres device. The pulse interval, from which pulse rate was derived, was obtained from the blood pressure signal. Due to the significant change in heart rhythm associated with thyrotoxicosis, both pulse interval (taken as a surrogate of heart period) and pulse rate (taken as a surrogate of heart rate) were computed. Power spectral analysis showed a reduction in the overall heart period variability in the supine position in the hyperthyroid compared to the euthyroid state. This effect was observed in the low-frequency (0.005-0.068 Hz), mid-frequency (0.068-0.127 Hz) and high-frequency (respiratory) domains as well, with a significant reduction of the modulus of these bands of 31%, 35% and 47%, respectively. The heart rate spectral modulus also exhibited a reduction of the high-frequency component (31%) in the supine position in the hyperthyroid subjects. These changes in heart rhythmicity corroborate a vagal deficit in hyperthyroidism. In addition, blood pressure spectral power exhibited a significant deficit in the orthostatism-induced mid-frequency systolic blood pressure rise in the hyperthyroid state (64%) compared with the euthyroid state. This observation may reflect a reduced vascular sympathetic activation with standing. The resulting vasodilatation could well contribute to normalize blood pressure in thyrotoxicosis in which cardiac output is increased.
Analysis of long term heart rate variability: methods, 1/f scaling and implications
NASA Technical Reports Server (NTRS)
Saul, J. P.; Albrecht, P.; Berger, R. D.; Cohen, R. J.
1988-01-01
The use of spectral techniques to quantify short term heart rate fluctuations on the order of seconds to minutes has helped define the autonomic contributions to beat-to-beat control of heart rate. We used similar techniques to quantify the entire spectrum (0.00003-1.0 Hz) of heart rate variability during 24 hour ambulatory ECG monitoring. The ECG from standard Holter monitor recordings from normal subjects was sampled with the use of a phase locked loop, and a heart rate time series was constructed at 3 Hz. Frequency analysis of the heart rate signal was performed after a nonlinear filtering algorithm was used to eliminate artifacts. A power spectrum of the entire 24 hour record revealed power that was inversely proportional to frequency, 1/f, over 4 decades from 0.00003 to 0.1 Hz (period approximately 10 hours to 10 seconds). Displaying consecutive spectra calculated at 5 minute intervals revealed marked variability in the peaks at all frequencies throughout the 24 hours, probably accounting for the lack of distinct peaks in the spectra of the entire records.
Li, Aiyan; Kuga, Keisuke; Suzuki, Akihiro; Endo, Masae; Niho, Bumpei; Enomoto, Mami; Kanemoto, Miyako; Yamaguchi, Iwao
2002-01-01
Heart rate is largely affected by the autonomic nervous system. However, little is known about the anatomic pathway of autonomic nerve fibers innervating the sinus node. The present study: (1) evaluates the effects of cavotricuspid isthmus ablation for common atrial flutter (AFL) on autonomic nervous function by using heart rate variability analysis, and (2) investigates the distribution of autonomic nerve pathways innervating the sinus node. Twelve patients with paroxysmal common atrial flutter who maintained sinus rhythm both before and after radiofrequency ablation were selected for the study. Holter ambulatory recordings were performed before and after (2.3 +/- 1.0 days) radiofrequency ablation of cavotricuspid isthmus. Heart rate and time domain (SDANN, rMSSD, pNN50) and frequency domain (low frequency (LF), high frequency (HF), LF/HF) analysis of heart rate variability were compared before and after ablation. Mean heart rate did not change significantly after ablation (59 +/- 6 vs 61 +/- 9 beats/min); parasympathetic indices of heart rate variability (SDANN, rMSSD, pNN50, HF) did not change significantly (110 +/- 37 vs 117 +/- 20 ms; 32 +/- 21 vs 28 +/- 9 ms; 4.8 +/- 0.9 vs 4.7 +/- 0.71n(ms2)); and sympathetic indices of heart rate variability (LF/HF) did not change significantly (1.1 +/- 0.2 vs 1.2 +/- 0.1). Cavotricuspid isthmus ablation for atrial flutter did not significantly change heart rate and heart rate variability because parasympathetic and sympathetic fibers innervating the sinus node are scarce in this region.
Effects of head-down bed rest on complex heart rate variability: Response to LBNP testing
NASA Technical Reports Server (NTRS)
Goldberger, Ary L.; Mietus, Joseph E.; Rigney, David R.; Wood, Margie L.; Fortney, Suzanne M.
1994-01-01
Head-down bed rest is used to model physiological changes during spaceflight. We postulated that bed rest would decrease the degree of complex physiological heart rate variability. We analyzed continuous heart rate data from digitized Holter recordings in eight healthy female volunteers (age 28-34 yr) who underwent a 13-day 6 deg head-down bed rest study with serial lower body negative pressure (LBNP) trials. Heart rate variability was measured on a 4-min data sets using conventional time and frequency domain measures as well as with a new measure of signal 'complexity' (approximate entropy). Data were obtained pre-bed rest (control), during bed rest (day 4 and day 9 or 11), and 2 days post-bed rest (recovery). Tolerance to LBNP was significantly reduced on both bed rest days vs. pre-bed rest. Heart rate variability was assessed at peak LBNP. Heart rate approximate entropy was significantly decreased at day 4 and day 9 or 11, returning toward normal during recovery. Heart rate standard deviation and the ratio of high- to low-power frequency did not change significantly. We conclude that short-term bed rest is associated with a decrease in the complex variability of heart rate during LBNP testing in healthy young adult women. Measurement of heart rate complexity, using a method derived from nonlinear dynamics ('chaos theory'), may provide a sensitive marker of this loss of physiological variability, complementing conventional time and frequency domain statistical measures.
Bhaumik, G; Dass, D; Bhattacharyya, D; Sharma, Y K; Singh, S B
2013-01-01
Acute exposure to hypobaric hypoxia induces the changes in autonomic control of heart rate. Due to emergencies or war like conditions, rapid deployment of Indian military personnel into high altitude frequently occurs. Rapid deployment to high altitude soldiers are at risk of developing high altitude sickness. The present study was conducted to evaluate the acute exposure to high altitude hypobaric hypoxia (3500 m altitude) on the autonomic nervous control of heart rate in Indian military personnel during first week of acclimatization Indices of heart rate variability (viz; R-R interval, total power, low frequency, high frequency, ratio of low to high frequency) and pulse arterial oxygen saturation were measured at sea level and 3500m altitude. Power spectrum of heart rate variability was quantified by low frequency (LF: 0.04-0.15 Hz) and high frequency (HF: 0.15-0.5 Hz) widths. The ratio of LF to HF was also assessed as an index of the sympathovagal balance. Mean R-R interval decreased significantly on day 2 on induction to altitude which tended to increase on day 5. Total power (TP) decreased high altitude and tended to recover within a week. Both HF and LF power showed decrement at 3500m in comparison to sea level. The ratio of LF to HF (LF/HF) at 3500m was significantly higher at 3500m. SpO2 values decreased significantly (P < 0.05) at high altitude on day-2 which increased on day-5. We conclude that autonomic control of the heart rate measured by heart rate variability was altered on acute induction to 3500m which showed a significant decrease in parasympathetic tone and increase in sympathetic tone, then acclimatization seems to be characterized by progressive shift toward a higher parasympathetic tone.
Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L
2014-01-01
Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.
Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L.
2014-01-01
Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain. PMID:25324790
The influence of low-frequency magnetic field on plasma antioxidant capacity and heart rate.
Ciejka, Elzbieta B; Goraca, Anna
2009-01-01
Low-frequency magnetic field is widely applied as magnetotherapy in physiotherapeutic treatment. Recognition of positive and negative effects of the magnetic field has been the subject of numerous studies. Experimental studies concern, among others, the effect of this field on the heart rate and plasma antioxidant capacity. The aim of the study was to check whether a time-variable magnetic field of constant frequency and induction affects the heart rate and plasma antioxidant capacity. The tests were performed on Spraque-Dawley rats exposed to the magnetic field of the following parameters: frequency - 40 Hz, induction - 7 mT, time of exposure - 30 and 60 minutes. The measurements of ECG and plasma antioxidant capacity expressed in the number of reduced iron ions were performed on experimental animals: before, after a single exposure and after 14 days of exposure. A significant decrease of the heart rate was observed after 14 days of exposure. A variable magnetic field of the parameters: frequency - 40 Hz, induction - 7 mT and exposure time of 14 days caused an increase of the organism antioxidant defence, whereas a variable magnetic field of the frequency of 40 Hz, induction - 7 mT and exposure time 60 minutes for 14 days caused a significant decrease of the organism antioxidant defence. The exposure time affects heart rate, plasma antioxidant capacity and the organism defense ability against free radicals.
Frequency-dependent baroreflex control of blood pressure and heart rate during physical exercise.
Spadacini, Giammario; Passino, Claudio; Leuzzi, Stefano; Valle, Felice; Piepoli, Massimo; Calciati, Alessandro; Sleight, Peter; Bernardi, Luciano
2006-02-15
It is widely recognised that during exercise vagal heart rate control is markedly impaired but blood pressure control may or may not be retained. We hypothesised that this uncertainty arose from the differing responses of the vagus (fast) and sympathetic (slow) arms of the autonomic effectors, and to differing sympatho-vagal balance at different exercise intensities. We studied 12 normals at rest, during moderate (50% maximal heart rate) and submaximal (80% maximal heart rate) exercise. The carotid baroreceptors were stimulated by sinusoidal neck suction at the frequency of the spontaneous high- (during moderate exercise) and low-frequency (during submaximal) fluctuations in heart period and blood pressure. The increases in these oscillations induced by neck suction were measured by autoregressive spectral analysis. At rest neck stimulation increased variability at low frequency (RR: from 6.99+/-0.24 to 8.87+/-0.18 ln-ms2; systolic pressure: from 3.05+/-1.7 to 4.09+/-0.17 ln-mm Hg2) and high frequency (RR: from 4.67+/-0.25 to 6.79+/-0.31 ln-ms2; systolic pressure: from 1.93+/-0.2 to 2.67+/-0.125 ln-mm Hg2) (all p<0.001). During submaximal exercise RR variability decreased but systolic pressure variability rose (p<0.01 vs rest); during submaximal exercise low-frequency neck stimulation increased the low-frequency fluctuations in blood pressure (2.35+/-0.51 to 4.25+/-0.38 ln-mm Hg2, p<0.05) and RR. Conversely, neck suction at high frequency was ineffective on systolic pressure, and had only minor effects on RR interval during moderate exercise. During exercise baroreflex control is active on blood pressure, but the efferent response on blood pressure and heart rate is only detected during low frequency stimulation, indicating a frequency-dependent effect.
Lee, Jong-Ho; Kim, Kyu-Hyeong; Hong, Jin-Woo; Lee, Won-Chul; Koo, Sungtae
2011-06-01
This study aimed to compare the effects of high frequency electroacupuncture (EA) and low-frequency EA on the autonomic nervous system by using a heart rate variability measuring device in normal individuals. Fourteen participants were recruited and each participated in the high-frequency and low-frequency sessions (crossover design). The order of sessions was randomized and the interval between the two sessions was over 2 weeks. Participants received needle insertion with 120-Hz stimulation during the high-frequency session (high-frequency EA group), and with 2-Hz stimulation during the low-frequency session (low-frequency EA group). Acupuncture needles were directly inserted perpendicularly to LI 4 and LI 11 acupoints followed by delivery of electric pulses to these points for 15 minutes. Heart rate variability was measured 5 minutes before and after EA stimulation by a heart rate variability measuring system. We found a significant increase in the standard deviation of the normal-to-normal interval in the high-frequency EA group, with no change in the low-frequency EA group. Both the high-frequency and low-frequency EA groups showed no significant differences in other parameters including high-frequency power, low-frequency power, and the ratio of low-frequency power to high-frequency power. Based on these findings, we concluded that high-frequency EA stimulation is more effective than low-frequency EA stimulation in increasing autonomic nervous activity and there is no difference between the two EA frequencies in enhancing sympathovagal balance. Copyright © 2011 Korean Pharmacopuncture Institute. Published by .. All rights reserved.
Sympathovagal imbalance in hyperthyroidism.
Burggraaf, J; Tulen, J H; Lalezari, S; Schoemaker, R C; De Meyer, P H; Meinders, A E; Cohen, A F; Pijl, H
2001-07-01
We assessed sympathovagal balance in thyrotoxicosis. Fourteen patients with Graves' hyperthyroidism were studied before and after 7 days of treatment with propranolol (40 mg 3 times a day) and in the euthyroid state. Data were compared with those obtained in a group of age-, sex-, and weight-matched controls. Autonomic inputs to the heart were assessed by power spectral analysis of heart rate variability. Systemic exposure to sympathetic neurohormones was estimated on the basis of 24-h urinary catecholamine excretion. The spectral power in the high-frequency domain was considerably reduced in hyperthyroid patients, indicating diminished vagal inputs to the heart. Increased heart rate and mid-frequency/high-frequency power ratio in the presence of reduced total spectral power and increased urinary catecholamine excretion strongly suggest enhanced sympathetic inputs in thyrotoxicosis. All abnormal features of autonomic balance were completely restored to normal in the euthyroid state. beta-Adrenoceptor antagonism reduced heart rate in hyperthyroid patients but did not significantly affect heart rate variability or catecholamine excretion. This is in keeping with the concept of a joint disruption of sympathetic and vagal inputs to the heart underlying changes in heart rate variability. Thus thyrotoxicosis is characterized by profound sympathovagal imbalance, brought about by increased sympathetic activity in the presence of diminished vagal tone.
Johansson, Benny
2008-10-01
This study explores the effects of vortex-water transpired from indoor greenery to office air, in relation to heart rate and heart rate variability during exposure to an electromagnetic field (EMF) from a visual display terminal (VDT). The study followed a randomized prospective single group cross-over design. Fifty (50) healthy volunteers, seated in any ordinary working posture in front of a VDT. Electrocardiography was measured in five 10-minute sequential tests. The VDT was turned off during the first test and switched on for the subsequent four tests. During tests 3 and 4, one of two Begonia Eliator plants, irrigated with either tap water or vortex-rotated (active) tap water during growth, was placed adjacent to the VDT. Heart rate, heart rate variability (HRV) and power spectral density (PSD) were analyzed. The heart rate was unchanged at the start of EMF exposure. The time domain measurements indicated a significant decrease in heart rate and a significant increase in HRV, accompanied by higher vagal tone in the presence, and finally in the absence, of the active plant. PSD parameters revealed significantly higher total power, as well as an increase in low frequencies (LF) and high frequencies (HF) in the condition induced by the active plant as well as after its removal. Very low frequencies (VLF) increased at EMF exposure whereas normally HF power decreased, accompanied by a rise in LF power and LF/HF ratio. HF power was higher at exposure to the active compared to the control plant. Spectral power density diagrams revealed an intensified spectral power band at frequencies of around 0.1 Hz at the condition of both plants, indicating systemic autonomic stability. The findings suggest that the parasympathetic response was associated with reduced heart rate, implicating restoration and maintenance of metabolic energy resources mediated by an involuntary adaptation to active plant-related stimuli.
Dumont, Martine; Jurysta, Fabrice; Lanquart, Jean-Pol; Noseda, André; van de Borne, Philippe; Linkowski, Paul
2007-12-01
To investigate the dynamics of the synchronization between heart rate variability and sleep electroencephalogram power spectra and the effect of sleep apnea-hypopnea syndrome. Heart rate and sleep electroencephalogram signals were recorded in controls and patients with sleep apnea-hypopnea syndrome that were matched for age, gender, sleep parameters, and blood pressure. Spectral analysis was applied to electrocardiogram and electroencephalogram sleep recordings to obtain power values every 20s. Synchronization likelihood was computed between time series of the normalized high frequency spectral component of RR-intervals and all electroencephalographic frequency bands. Detrended fluctuation analysis was applied to the synchronizations in order to qualify their dynamic behaviors. For all sleep bands, the fluctuations of the synchronization between sleep EEG and heart activity appear scale free and the scaling exponent is close to one as for 1/f noise. We could not detect any effect due to sleep apnea-hypopnea syndrome. The synchronizations between the high frequency component of heart rate variability and all sleep power bands exhibited robust fluctuations characterized by self-similar temporal behavior of 1/f noise type. No effects of sleep apnea-hypopnea syndrome were observed in these synchronizations. Sleep apnea-hypopnea syndrome does not affect the interdependence between the high frequency component of heart rate variability and all sleep power bands as measured by synchronization likelihood.
NASA Technical Reports Server (NTRS)
Triedman, J. K.; Perrott, M. H.; Cohen, R. J.; Saul, J. P.
1995-01-01
Fourier-based techniques are mathematically noncausal and are therefore limited in their application to feedback-containing systems, such as the cardiovascular system. In this study, a mathematically causal time domain technique, autoregressive moving average (ARMA) analysis, was used to parameterize the relations of respiration and arterial blood pressure to heart rate in eight humans before and during total cardiac autonomic blockade. Impulse-response curves thus generated showed the relation of respiration to heart rate to be characterized by an immediate increase in heart rate of 9.1 +/- 1.8 beats.min-1.l-1, followed by a transient mild decrease in heart rate to -1.2 +/- 0.5 beats.min-1.l-1 below baseline. The relation of blood pressure to heart rate was characterized by a slower decrease in heart rate of -0.5 +/- 0.1 beats.min-1.mmHg-1, followed by a gradual return to baseline. Both of these relations nearly disappeared after autonomic blockade, indicating autonomic mediation. Maximum values obtained from the respiration to heart rate impulse responses were also well correlated with frequency domain measures of high-frequency "vagal" heart rate control (r = 0.88). ARMA analysis may be useful as a time domain representation of autonomic heart rate control for cardiovascular modeling.
Galli, Gina L J; Gesser, Hans; Taylor, Edwin W; Shiels, Holly A; Wang, Tobias
2006-05-01
The functional significance of the sarcoplasmic reticulum (SR) in the generation of high heart rates and blood pressures was investigated in four species of reptile; the turtle, Trachemys scripta; the python, Python regius, the tegu lizard, Tupinanvis merianae, and the varanid lizard, Varanus exanthematicus. Force-frequency trials and imposed pauses were performed on ventricular and atrial tissue from each species with and without the SR inhibitor ryanodine, and in the absence and presence of adrenaline. In all species, an imposed pause of 1 or 5 min caused a post-rest decay of force, and a negative force-frequency response was observed in all species within their in vivo frequency range of heart rates. These relationships were not affected by either ryanodine or adrenaline. In ventricular strips from varanid lizards and pythons, ryanodine caused significant reductions in twitch force within their physiologically relevant frequency range. In atrial tissue from the tegu and varanid lizards, SR inhibition reduced twitch force across the whole of their physiological frequency range. In contrast, in the more sedentary species, the turtle and the python, SR inhibition only decreased twitch force at stimulation frequencies above maximal in vivo heart rates. Adrenaline caused an increase in twitch force in all species studied. In ventricular tissue, this positive inotropic effect was sufficient to overcome the negative effects of ryanodine. In atrial tissue however, adrenaline could only ameliorate the negative effects of ryanodine at the lower pacing frequencies. Our results indicate that reptiles recruit Ca2+ from the SR for force development in a frequency and tissue dependent manner. This is discussed in the context of the development of high reptilian heart rates and blood pressures.
Matusik, P S; Matusik, P T; Stein, P K
2018-07-01
Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.
Heart Rate Changes in Electroacupuncture Treated Polycystic Ovary in Rats.
Ramadoss, Mukilan; Ramanathan, Gunasekaran; Subbiah, Angelie Jessica; Natrajan, Chidambaranathan
2016-03-01
Polycystic Ovary Syndrome (PCOS) is a common metabolic disorder, it affects both humans and animals. It may induce coronary heart disease, obesity and hyperandrogenism. Previous studies show that Low frequency Electroacupuncture (EA) have an effect on PCOS, however the exact pathway is unclear. To find the effect of EA on autonomic activity of the heart in Estradiol Valerate (EV) induced PCOS rats. Heart rate variability (HRV) was assessed in 3 groups: 1) Control; 2) PCOS rats; and 3) PCOS rats after EA treatment (n=8 in each group). From the time domain analysis and frequency domain analysis (linear measures) HRV analysis was done. EA stimulation was given at low frequency of 2Hz for 15 min on alternate days for 4-5 weeks. Collected data were statistically analysed using One-Way Analysis of Variance with the application of multiple comparisons of Tukey test. EA treatment group shows significant reduction in Heart Rate (HR) and low frequency, high frequency ratio (LF/HF); and increase in RR interval, Total Power (TP) when compared to PCOS group. The study concludes that EA treatment has a significant effect on reducing sympathetic tone and decreasing HR in PCOS.
Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.
Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel
2018-03-01
Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).
Ito, Koji; Miyata, Kenji; Mohri, Masahiro; Origuchi, Hideki; Yamamoto, Hideo
Objective It is recommended that middle-aged and elderly individuals reduce their salt intake because of the high prevalence of hypertension. The consumption of miso soup is associated with salt intake, and the reduced consumption of miso soup has been recommended. Recent studies have demonstrated that the consumption of miso soup can attenuate an autonomic imbalance in animal models. However, it is unclear whether these results are applicable to humans. This study examined the cross-sectional association between the frequency of miso soup consumption and the blood pressure and heart rate of human subjects. Methods A total of 527 subjects of 50 to 81 years of age who participated in our hospital health examination were enrolled in the present study and divided into four groups based on the frequency of their miso soup consumption ([bowl(s) of miso soup/week] Group 1, <1; Group2, <4; Group3, <7; Group4, ≥7). The blood pressure levels and heart rates of the subjects in each group were compared. Furthermore, a multivariable analysis was performed to determine whether miso soup consumption was an independent factor affecting the incidence of hypertension or the heart rate. Results The frequency of miso soup consumption was not associated with blood pressure. The heart rate was, however, lower in the participants who reported a high frequency of miso soup consumption. A multivariable analysis revealed that the participants who reported a high frequency of miso soup consumption were more likely to have a lower heart rate, but that the consumption of miso soup was not associated with the incidence of hypertension. Conclusion These results indicate that miso soup consumption might decrease the heart rate, but not have a significant effect on the blood pressure of in middle-aged and elderly Japanese individuals.
Ito, Koji; Miyata, Kenji; Mohri, Masahiro; Origuchi, Hideki; Yamamoto, Hideo
2017-01-01
Objective It is recommended that middle-aged and elderly individuals reduce their salt intake because of the high prevalence of hypertension. The consumption of miso soup is associated with salt intake, and the reduced consumption of miso soup has been recommended. Recent studies have demonstrated that the consumption of miso soup can attenuate an autonomic imbalance in animal models. However, it is unclear whether these results are applicable to humans. This study examined the cross-sectional association between the frequency of miso soup consumption and the blood pressure and heart rate of human subjects. Methods A total of 527 subjects of 50 to 81 years of age who participated in our hospital health examination were enrolled in the present study and divided into four groups based on the frequency of their miso soup consumption ([bowl(s) of miso soup/week] Group 1, <1; Group2, <4; Group3, <7; Group4, ≥7). The blood pressure levels and heart rates of the subjects in each group were compared. Furthermore, a multivariable analysis was performed to determine whether miso soup consumption was an independent factor affecting the incidence of hypertension or the heart rate. Results The frequency of miso soup consumption was not associated with blood pressure. The heart rate was, however, lower in the participants who reported a high frequency of miso soup consumption. A multivariable analysis revealed that the participants who reported a high frequency of miso soup consumption were more likely to have a lower heart rate, but that the consumption of miso soup was not associated with the incidence of hypertension. Conclusion These results indicate that miso soup consumption might decrease the heart rate, but not have a significant effect on the blood pressure of in middle-aged and elderly Japanese individuals. PMID:28049996
Addison, Paul S; Foo, David M H; Jacquel, Dominique
2017-07-01
The extraction of heart rate from a video-based biosignal during motion using a novel wavelet-based ensemble averaging method is described. Running Wavelet Archetyping (RWA) allows for the enhanced extraction of pulse information from the time-frequency representation, from which a video-based heart rate (HRvid) can be derived. This compares favorably to a reference heart rate derived from a pulse oximeter.
Association of auricular pressing and heart rate variability in pre-exam anxiety students.
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-03-25
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety.
Association of auricular pressing and heart rate variability in pre-exam anxiety students
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-01-01
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety. PMID:25206734
Poupard, Laurent; Court-Fortune, Isabelle; Pichot, Vincent; Chouchou, Florian; Barthélémy, Jean-Claude; Roche, Frédéric
2011-12-01
Several studies have correlated the ratio of the very low frequency power spectral density of heart rate increment (%VLFI) with obstructive sleep apnoea syndrome (OSAS). However, patients with impaired heart rate variability may exhibit large variations of heart rate increment (HRI) spectral pattern and alter the screening accuracy of the method. To overcome this limitation, the present study uses the high-frequency increment (HFI) peak in the HRI spectrum, which corresponds to the respiratory influence on RR variations over the frequency range 0.2 to 0.4 Hz. We evaluated 288 consecutive patients referred for snoring, observed nocturnal breathing cessation and/or daytime sleepiness. Patients were classified as OSAS if their apnoea plus hypopnoea index (AHI) during polysomnography exceeded 15 events per hour. Synchronized electrocardiogram Holter monitoring allowed HRI analysis. Using a %VLFI threshold >2.4% for identifying the presence of OSAS, sensitivity for OSAS was 74.9%, specificity 51%, positive predictive value 54.9% and negative predictive value 71.7% (33 false negative subjects). Using threshold for %VLFI >2.4% and HFI peak position >0.4 Hz, negative predictive value increased to 78.2% while maintaining specificity at 50.6%. Among 11 subjects with %VLFI <2.4% and HFI peak >0.4 Hz, nine demonstrated moderate to severe OSAS (AHI >30). HFI represents a minimal physiological criterion for applying %VLFI by ensuring that heart rate variations are band frequency limited.
Kommers, Deedee R; Joshi, Rohan; van Pul, Carola; Atallah, Louis; Feijs, Loe; Oei, Guid; Bambang Oetomo, Sidarto; Andriessen, Peter
2017-03-01
To determine whether heart rate variability (HRV) can serve as a surrogate measure to track regulatory changes during kangaroo care, a period of parental coregulation distinct from regulation within the incubator. Nurses annotated the starting and ending times of kangaroo care for 3 months. The pre-kangaroo care, during-kangaroo care, and post-kangaroo care data were retrieved in infants with at least 10 accurately annotated kangaroo care sessions. Eight HRV features (5 in the time domain and 3 in the frequency domain) were used to visually and statistically compare the pre-kangaroo care and during-kangaroo care periods. Two of these features, capturing the percentage of heart rate decelerations and the extent of heart rate decelerations, were newly developed for preterm infants. A total of 191 kangaroo care sessions were investigated in 11 preterm infants. Despite clinically irrelevant changes in vital signs, 6 of the 8 HRV features (SD of normal-to-normal intervals, root mean square of the SD, percentage of consecutive normal-to-normal intervals that differ by >50 ms, SD of heart rate decelerations, high-frequency power, and low-frequency/high-frequency ratio) showed a visible and statistically significant difference (P <.01) between stable periods of kangaroo care and pre-kangaroo care. HRV was reduced during kangaroo care owing to a decrease in the extent of transient heart rate decelerations. HRV-based features may be clinically useful for capturing the dynamic changes in autonomic regulation in response to kangaroo care and other changes in environment and state. Copyright © 2016 Elsevier Inc. All rights reserved.
Nemati, Shamim; Edwards, Bradley A.; Lee, Joon; Pittman-Polletta, Benjamin; Butler, James P.; Malhotra, Atul
2013-01-01
Aging and disease are accompanied with a reduction of complex variability in the temporal patterns of heart rate. This reduction has been attributed to a break down of the underlying regulatory feedback mechanisms that maintain a homeodynamic state. Previous work has established the utility of entropy as an index of disorder, for quantification of changes in heart rate complexity. However, questions remain regarding the origin of heart rate complexity and the mechanisms involved in its reduction with aging and disease. In this work we use a newly developed technique based on the concept of band-limited transfer entropy to assess the aging-related changes in contribution of respiration and blood pressure to entropy of heart rate at different frequency bands. Noninvasive measurements of heart beat interval, respiration, and systolic blood pressure were recorded from 20 young (21–34 years) and 20 older (68–85 years) healthy adults. Band-limited transfer entropy analysis revealed a reduction in high-frequency contribution of respiration to heart rate complexity (p < 0.001) with normal aging, particularly in men. These results have the potential for dissecting the relative contributions of respiration and blood pressure-related reflexes to heart rate complexity and their degeneration with normal aging. PMID:23811194
USDA-ARS?s Scientific Manuscript database
Understanding autonomic nervous system functioning, which mediates behavioral and physiological responses to stress, offers great potential for evaluation of farm animal stress and welfare. Evaluation of heart rate variability (HRV) and blood pressure variability (BPV), using time and frequency doma...
Detection of cardiac activity using a 5.8 GHz radio frequency sensor.
Vasu, V; Fox, N; Brabetz, T; Wren, M; Heneghan, C; Sezer, S
2009-01-01
A 5.8-GHz ISM-Band radio-frequency sensor has been developed for non-contact measurement of respiration and heart rate from stationary and semi-stationary subjects at a distance of 0.5 to 1.5 meters. We report on the accuracy of the heart rate measurements obtained using two algorithmic approaches, as compared to a reference heart rate obtained using a pulse oximeter. Simultaneous Photoplethysmograph (PPG) and non-contact sensor recordings were recorded over fifteen minute periods for ten healthy subjects (8M/2F, ages 29.6 + or - 5.6 yrs) One algorithm is based on automated detection of individual peaks associated with each cardiac cycle; a second algorithm extracts a heart rate over a 60-second period using spectral analysis. Peaks were also extracted manually for comparison with the automated method. The peak-detection methods were less accurate than the spectral methods, but suggest the possibility of acquiring beat by beat data; the spectral algorithms measured heart rate to within + or -10% for the ten subjects chosen. Non-contact measurement of heart rate will be useful in chronic disease monitoring for conditions such as heart failure and cardiovascular disease.
[Voluntary alpha-power increasing training impact on the heart rate variability].
Bazanova, O M; Balioz, N V; Muravleva, K B; Skoraia, M V
2013-01-01
In order to study the effect of the alpha EEG power increasing training at heart rate variability (HRV) as the index of the autonomic regulation of cognitive functions there were follow tasks: (1) to figure out the impact of biofeedback in the voluntary increasing the power in the individual high-frequency alpha-band effect on heart rate variability and related characteristics of cognitive and emotional spheres, (2) to determine the nature of the relationship between alpha activity indices and heart rate variability, depending on the alpha-frequency EEG pattern at rest (3) to examine how the individual alpha frequency EEG pattern is reflected in changes HRV as a result of biofeedback training. Psychometric indicators of cognitive performance, the characteristics of the alpha-EEG activity and heart rate variability (HRV) as LF/HF and pNN50 were recorded in 27 healthy men aged 18-34 years, before, during, and after 10 sessions of training of voluntary increase in alpha power in the individual high-frequency alpha band with eyes closed. To determine the biofeedback effect on the alpha power increasing training, data subjects are compared in 2 groups: experimental (14) with the real and the control group (13 people)--with mock biofeedback. The follow up effect of trainings was studied through month over the 10 training sessions. Results showed that alpha biofeedback training enhanced the fluency and accuracy in cognitive performance, decreased anxiety and frontal EMG, increased resting frequency, width and power in individual upper alpha range only in participants with low baseline alpha frequency. While mock biofeedback increased resting alpha power only in participants with high baseline resting alpha frequency and did change neither cognitive performance, nor HRV indices. Biofeedback training eliminated the alpha power decrease in response to arithmetic task in both with high and low alpha frequency participants and this effect was followed up over the month. Mock biofeedback training has no such effect. The positive correlation between the alpha-peak frequency and pNN50 in patients with initially low, but negative--those with high baseline alpha frequency explains the multidirectional biofeedback effects on HRV in low and high alpha frequency subjects. The individual alpha-frequency EEG pattern determines the effectiveness of the alpha EEG biofeedback training in changing heart rate variability, which provides a basis for predicting the results and develop individual approaches to the biofeedback technology implementation that can be used in clinical practice for treatment and rehabilitation of psychosomatic syndromes and in educational training.
Heart rate variability and pain: associations of two interrelated homeostatic processes.
Appelhans, Bradley M; Luecken, Linda J
2008-02-01
Between-person variability in pain sensitivity remains poorly understood. Given a conceptualization of pain as a homeostatic emotion, we hypothesized inverse associations between measures of resting heart rate variability (HRV), an index of autonomic regulation of heart rate that has been linked to emotionality, and sensitivity to subsequently administered thermal pain. Resting electrocardiography was collected, and frequency-domain measures of HRV were derived through spectral analysis. Fifty-nine right-handed participants provided ratings of pain intensity and unpleasantness following exposure to 4 degrees C thermal pain stimulation, and indicated their thresholds for barely noticeable and moderate pain during three exposures to decreasing temperature. Greater low-frequency HRV was associated with lower ratings of 4 degrees C pain unpleasantness and higher thresholds for barely noticeable and moderate pain. High-frequency HRV was unrelated to measures of pain sensitivity. Findings suggest pain sensitivity is influenced by characteristics of a central homeostatic system also involved in emotion.
Ichimaru, Y; Yanaga, T
1989-06-01
Spectral analysis of heart rates during 24-hr ambulatory electrocardiographic monitoring has been carried out to characterize the heart rate spectral components of Cheyne-Stokes respiration (CSR) by using fast Fourier transformation (FFT). Eight patients with congestive heart failure were selected for the study. FFT analyses have been performed for 614.4 sec. Out of the power spectrum, five parameters were extracted to characterize the CSR. The low peak frequencies in eight subjects were between 0.0179 Hz (56 sec) and 0.0081 Hz (123 sec). The algorithms used to detect CSR are the followings: (i) if the LFPA/ULFA ratios were above the absolute value of 1.0, and (ii) the LFPP/MLFP ratios were above the absolute values of 4.0, then the power spectrum is suggestive of CSR. We conclude that the automatic detection of CSR by heart rate spectral analysis during ambulatory ECG monitoring may afford a tool for the evaluation of the patients with congestive heart failure.
Massaro, An N; Campbell, Heather E; Metzler, Marina; Al-Shargabi, Tareq; Wang, Yunfei; du Plessis, Adre; Govindan, Rathinaswamy B
2017-04-01
To determine whether measures of heart rate variability are related to changes in temperature during rewarming after therapeutic hypothermia for hypoxic-ischemic encephalopathy. Prospective observational study. Level 4 neonatal ICU in a free-standing academic children's hospital. Forty-four infants with moderate to severe hypoxic-ischemic encephalopathy treated with therapeutic hypothermia. Continuous electrocardiogram data from 2 hours prior to rewarming through 2 hours after completion of rewarming (up to 10 hr) were analyzed. Median beat-to-beat interval and measures of heart rate variability were quantified including beat-to-beat interval SD, low and high frequency relative spectral power, detrended fluctuation analysis short and long α exponents (αS and αL), and root mean square short and long time scales. The relationships between heart rate variability measures and esophageal/axillary temperatures were evaluated. Heart rate variability measures low frequency, αS, and root mean square short and long time scales were negatively associated, whereas αL was positively associated, with temperature (p < 0.01). These findings signify an overall decrease in heart rate variability as temperature increased toward normothermia. Measures of heart rate variability are temperature dependent in the range of therapeutic hypothermia to normothermia. Core body temperature needs to be considered when evaluating heart rate variability metrics as potential physiologic biomarkers of illness severity in hypoxic-ischemic encephalopathy infants undergoing therapeutic hypothermia.
Wadehn, Federico; Carnal, David; Loeliger, Hans-Andrea
2015-08-01
Heart rate variability is one of the key parameters for assessing the health status of a subject's cardiovascular system. This paper presents a local model fitting algorithm used for finding single heart beats in photoplethysmogram recordings. The local fit of exponentially decaying cosines of frequencies within the physiological range is used to detect the presence of a heart beat. Using 42 subjects from the CapnoBase database, the average heart rate error was 0.16 BPM and the standard deviation of the absolute estimation error was 0.24 BPM.
The Relation of Arm Exercise Peak Heart Rate to Stress Test Results and Outcome.
Xian, Hong; Liu, Weijian; Marshall, Cynthia; Chandiramani, Pooja; Bainter, Emily; Martin, Wade H
2016-09-01
Arm exercise is an alternative to pharmacologic stress testing for >50% of patients unable to perform treadmill exercise, but no data exist regarding the effect of attained peak arm exercise heart rate on test sensitivity. Thus, the purpose of this investigation was to characterize the relationship of peak arm exercise heart rate responses to abnormal stress test findings, coronary revascularization, and mortality in patients unable to perform leg exercise. From 1997 until 2002, arm cycle ergometer stress tests were performed in 443 consecutive veterans age 64.1 yr (11.0 yr) (mean (SD)), of whom 253 also underwent myocardial perfusion imaging (MPI). Patients were categorized by frequency distributions of quartiles of percentage age-predicted peak heart rate (APPHR), heart rate reserve (HRR), and peak heart rate-systolic blood pressure product (PRPP). Exercise-induced ST-segment depression, abnormal MPI findings, coronary revascularization, and 12.0-yr (1.3 yr) Kaplan-Meier all-cause and cardiovascular mortality plots were then characterized by quartiles of APPHR, HRR, and PRPP. A reduced frequency of abnormal arm exercise ECG results was associated only with the lowest quartile of APPHR (≤69%) and HRR (≤43%), whereas higher frequency of abnormal MPI findings exhibited an inverse relationship trend with lower APPHR (P = 0.10) and HRR (P = 0.12). There was a strong inverse association of APPHR, HRR, and PRPP with all-cause (all P ≤ 0.01) and cardiovascular (P < 0.05) mortality. The frequency of coronary revascularization was unrelated to APPHR or HRR. Arm exercise ECG stress test sensitivity is only reduced at ≤69% APPHR or ≤43% HRR, whereas arm exercise MPI sensitivity and referral for coronary revascularization after arm exercise stress testing are not adversely affected by even a severely blunted peak heart rate. However, both all-cause mortality and cardiovascular mortality are strongly and inversely related to APPHR and HRR.
Lu, Xi; Hui-Chan, Christina Wan-Ying; Tsang, William Wai-Nam
2016-11-01
[Purpose] Exercise has been shown to improve cardiovascular fitness and cognitive function. Whether the inclusion of mind over exercise would increase parasympathetic control of the heart and brain activities more than general exercise at a similar intensity is not known. The aim of this study was to compare the effects of Tai Chi (mind-body exercise) versus arm ergometer cycling (body-focused exercise) on the heart rate variability and prefrontal oxygenation level. [Subjects and Methods] A Tai Chi master was invited to perform Tai Chi and arm ergometer cycling with similar exercise intensity on two separate days. Heart rate variability and prefrontal oxyhemoglobin levels were measured continuously by a RR recorder and near-infrared spectroscopy, respectively. [Results] During Tai Chi exercise, spectral analysis of heart rate variability demonstrated a higher high-frequency power as well as a lower low-frequency/high-frequency ratio than during ergometer cycling, suggesting increased parasympathetic and decreased sympathetic control of the heart. Also, prefrontal oxyhemoglobin and total hemoglobin levels were higher than those during arm ergometer exercise. [Conclusion] These findings suggest that increased parasympathetic control of the heart and prefrontal activities may be associated with Tai Chi practice. Having a "mind" component in Tai Chi could be more beneficial for older adults' cardiac health and cognitive function than body-focused ergometer cycling.
Oh, Myung Ok; Kim, Young Jeoum; Baek, Cho Hee; Kim, Ju Hee; Park, No Mi; Yu, Mi Jeong; Song, Han Sol
2016-06-01
The purpose of this cross-over experimental study was to examine effects of music intervention on maternal anxiety, fetal heart rate pattern and testing time during non-stress tests (NST) for antenatal fetal assessment. Sixty pregnant women within 28 to 40 gestational weeks were randomly assigned to either the experimental group (n=30) or control group (n=30). Music intervention was provided to pregnant women in the experimental group during NST. Degree of maternal anxiety and fetal heart rate pattern were our primary outcomes. State-trait anxiety inventory, blood pressure, pulse rate, and changes in peripheral skin temperature were assessed to determine the degree of maternal anxiety. Baseline fetal heart rate, frequency of acceleration in fetal heart rate, fetal movement test and testing time for reactive NST were assessed to measure the fetal heart rate pattern. The experimental group showed significantly lower scores in state anxiety than the control group. There were no significant differences in systolic blood pressure and pulse rate between the two groups. Baseline fetal heart rate was significantly lower in the experimental group than in the control group. Frequency of acceleration in fetal heart rate was significantly increased in the experimental group compared to the control group. There were no significant differences in fetal movement and testing time for reactive NST between the two groups. Present results suggest that music intervention could be an effective nursing intervention for alel viating anxiety during non-stress test.
Derkacz, Arkadiusz; Gawrys, Jakub; Gawrys, Karolina; Podgorski, Maciej; Magott-Derkacz, Agnieszka; Poreba, Rafał; Doroszko, Adrian
2018-06-01
The effect of electromagnetic field on cardiovascular system in the literature is defined in ambiguous way. The aim of this study was to evaluate the effect of electromagnetic field on the heart rate variability (HRV) during the examination with magnetic resonance. Forty-two patients underwent Holter ECG heart monitoring for 30 minutes twice: immediately before and after the examination with magnetic resonance imaging (MRI). HRV was analysed by assessing a few selected time and spectral parameters. Is has been shown that standard deviation of NN intervals (SDNN) and very low frequency rates increased, whereas the low frequency:high frequency parameter significantly decreased following the MRI examination. These results show that MRI may affect the HRV most likely by changing the sympathetic-parasympathetic balance.
Examining the Influence of Heartbeat on Expert Marksman Performance
2016-04-01
factors, such as heartbeat and heart rate, may play a role on a marksman’s shot as well. For instance, work has been done to determine the effect of... heart rate on expert marksmanship. The results of that work show that an expert marksman’s performance did not change in regard to heart rate. (Pojman...marksmanship phase. (The ECG values are not to be confused with the heart rate, which is the frequency of the cardiac cycle.) The heartbeat on an ECG is
Digital computing cardiotachometer
NASA Technical Reports Server (NTRS)
Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)
1973-01-01
A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.
Wustmann, Kerstin; Kucera, Jan P; Scheffers, Ingrid; Mohaupt, Markus; Kroon, Abraham A; de Leeuw, Peter W; Schmidli, Jürg; Allemann, Yves; Delacrétaz, Etienne
2009-09-01
In patients with drug-resistant hypertension, chronic electric stimulation of the carotid baroreflex is an investigational therapy for blood pressure reduction. We hypothesized that changes in cardiac autonomic regulation can be demonstrated in response to chronic baroreceptor stimulation, and we analyzed the correlation with blood pressure changes. Twenty-one patients with drug-resistant hypertension were prospectively included in a substudy of the Device Based Therapy in Hypertension Trial. Heart rate variability and heart rate turbulence were analyzed using 24-hour ECG. Recordings were obtained 1 month after device implantation with the stimulator off and after 3 months of chronic electric stimulation (stimulator on). Chronic baroreceptor stimulation decreased office blood pressure from 185+/-31/109+/-24 mm Hg to 154+/-23/95+/-16 mm Hg (P<0.0001/P=0.002). Mean heart rate decreased from 81+/-11 to 76+/-10 beats per minute(-1) (P=0.001). Heart rate variability frequency-domain parameters assessed using fast Fourier transformation (FFT; ratio of low frequency:high frequency: 2.78 versus 2.24 for off versus on; P<0.001) were significantly changed during stimulation of the carotid baroreceptor, and heart rate turbulence onset was significantly decreased (turbulence onset: -0.002 versus -0.015 for off versus on; P=0.004). In conclusion, chronic baroreceptor stimulation causes sustained changes in heart rate variability and heart rate turbulence that are consistent with inhibition of sympathetic activity and increase of parasympathetic activity in patients with drug-resistant systemic hypertension; these changes correlate with blood pressure reduction. Whether the autonomic modulation has favorable cardiovascular effects beyond blood pressure control should be investigated in further studies.
Heart-rate pulse-shift detector
NASA Technical Reports Server (NTRS)
Anderson, M.
1974-01-01
Detector circuit accurately separates and counts phase-shift pulses over wide range of basic pulse-rate frequency, and also provides reasonable representation of full repetitive EKG waveform. Single telemeter implanted in small animal monitors not only body temperature but also animal movement and heart rate.
Caswell, Joseph M; Singh, Manraj; Persinger, Michael A
2016-08-01
Previous research investigating the potential influence of geomagnetic factors on human cardiovascular state has tended to converge upon similar inferences although the results remain relatively controversial. Furthermore, previous findings have remained essentially correlational without accompanying experimental verification. An exception to this was noted for human brain activity in a previous study employing experimental simulation of sudden geomagnetic impulses in order to assess correlational results that had demonstrated a relationship between geomagnetic perturbations and neuroelectrical parameters. The present study employed the same equipment in a similar procedure in order to validate previous findings of a geomagnetic-cardiovascular dynamic with electrocardiography and heart rate variability measures. Results indicated that potential magnetic field effects on frequency components of heart rate variability tended to overlap with previous correlational studies where low frequency power and the ratio between low and high frequency components of heart rate variability appeared affected. In the present study, a significant increase in these particular parameters was noted during geomagnetic simulation compared to baseline recordings. Copyright © 2016 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
Baker, Jacquie; Racosta, Juan M; Balint, Brittany; Kimpinski, Kurt
2018-03-01
The clinical significance of heart rate variability in the context of autonomic dysfunction continues to be a matter of debate. A consensus is lacking on the best heart rate variability measures for clinical purposes. Therefore, the purpose of this study was to investigate the utility of heart rate variability parameters in healthy versus autonomic dysfunction. Healthy young (n = 134), healthy older (n = 32), and patients with mild (postural tachycardia syndrome; n = 25) and severe (neurogenic orthostatic hypotension; n = 34) autonomic dysfunction were included. Time and frequency parameters during baseline, head-up tilt (HUT), and heart rate response to deep breathing (HRDB) were compared. Cardiovagal time parameters were significantly reduced during HUT in healthy young and postural tachycardia syndrome (P < 0.001). Healthy young had significantly higher time parameters during baseline, HUT, and HRDB (P < 0.01). This was reflected by a significantly lower resting heart rate (HR) (61.4 ± 9.0 bpm vs. 76.8 ± 13.6 bpm; P < 0.001) and a smaller [INCREMENT]HR during HUT (32.8 ± 10.5 bpm vs. 44.4 ± 13.3 bpm; P < 0.001). Time parameters increased in young and postural tachycardia syndrome during HRDB, which was characterized by a nonsignificant difference in [INCREMENT]HR between both groups. Time parameters were significantly higher in healthy old versus neurogenic orthostatic hypotension at rest and during HRDB (P < 0.05). During HUT, only the SD of all normal RR intervals remained significantly higher. Heart rate changes corroborated these findings. Resting HR was significantly lower in healthy older (62.6 ± 11.0 bpm vs. 70.7 ± 12.4 bpm), and [INCREMENT]HR during HRDB was significantly higher (15.9 ± 9.2 bpm vs. 3.9 ± 4.2 bpm; P < 0.001). During HUT, [INCREMENT]HR showed no significant differences. Time domain parameters of heart rate variability have a greater utility than frequency parameters in clinical autonomic disorders.
Park, Gewnhi; Moon, Eunok; Kim, Do-Won; Lee, Seung-Hwan
2012-12-01
A previous study has shown that greater cardiac vagal tone, reflecting effective self-regulatory capacity, was correlated with superior visual discrimination of fearful faces at high spatial frequency Park et al. (Biological Psychology 90:171-178, 2012b). The present study investigated whether individual differences in cardiac vagal tone (indexed by heart rate variability) were associated with different event-related brain potentials (ERPs) in response to fearful and neutral faces. Thirty-six healthy participants discriminated the emotion of fearful and neutral faces at broad, high, and low spatial frequencies, while ERPs were recorded. Participants with low resting heart rate variability-characterized by poor functioning of regulatory systems-exhibited significantly greater N200 activity in response to fearful faces at low spatial frequency and greater LPP responses to neutral faces at high spatial frequency. Source analyses-estimated by standardized low-resolution brain electromagnetic tomography (sLORETA)-tended to show that participants with low resting heart rate variability exhibited increased source activity in visual areas, such as the cuneus and the middle occipital gyrus, as compared with participants with high resting heart rate variability. The hyperactive neural activity associated with low cardiac vagal tone may account for hypervigilant response patterns and emotional dysregulation, which heightens the risk of developing physical and emotional problems.
Combinatorial effect of nicotine and black tea on heart rate variability: Useful or harmful?
Joukar, S; Sheibani, M
2017-06-01
The effect of nicotine on heart rate variability (HRV) is controversial. Autonomic nervous system is the main regulator of heart rhythm, and heart rate variability is an appropriate index to assessment of the effects of the autonomic system on heart. In this study, the combination effect of nicotine and black tea consumption on sympatho-vagal balance and heart rate variability was investigated in rats. Male Wistar rats were randomized into four groups as control, tea (2.5 g/100 cc, daily), nicotine (2 mg/kg/d) and tea plus nicotine groups which treated for 28 days, and in the 29th day, their electrocardiograms (lead II) were recorded. The mean of high-frequency power (HF) in tea, nicotine and tea plus nicotine groups was significantly more than control group (P < .05), and low-frequency power/high-frequency power (LF/HF) ratio in the nicotine and tea + nicotine groups was significantly less than control group (P < .05). LF values did not differ significantly among groups. Mean of standard deviation of normal RR intervals (SDNN) and square root of the mean squared differences of successive RR intervals (RMSSD) increased significantly in tea, nicotine and tea + nicotine groups in comparison with control group (P < .05) Overall, 4-week administration of black tea, nicotine or their combination with dosages used in this study can increase the heart rate variability and improve the sympatho-vagal balance in rat. © 2017 John Wiley & Sons Ltd.
Diminution of Heart Rate Variability in Bipolar Depression
Hage, Brandon; Britton, Briana; Daniels, David; Heilman, Keri; Porges, Stephen W.; Halaris, Angelos
2017-01-01
Autonomic nervous system (ANS) dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV) provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD) patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia) was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20) than controls (ln = 5.50) (p < 0.01). Baseline heart period was significantly shorter (i.e., faster heart rate) in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients. PMID:29270399
Van Nguyen; Javaid, Abdul Q; Weitnauer, Mary Ann
2014-01-01
We introduce the Spectrum-averaged Harmonic Path (SHAPA) algorithm for estimation of heart rate (HR) and respiration rate (RR) with Impulse Radio Ultrawideband (IR-UWB) radar. Periodic movement of human torso caused by respiration and heart beat induces fundamental frequencies and their harmonics at the respiration and heart rates. IR-UWB enables capture of these spectral components and frequency domain processing enables a low cost implementation. Most existing methods of identifying the fundamental component either in frequency or time domain to estimate the HR and/or RR lead to significant error if the fundamental is distorted or cancelled by interference. The SHAPA algorithm (1) takes advantage of the HR harmonics, where there is less interference, and (2) exploits the information in previous spectra to achieve more reliable and robust estimation of the fundamental frequency in the spectrum under consideration. Example experimental results for HR estimation demonstrate how our algorithm eliminates errors caused by interference and produces 16% to 60% more valid estimates.
Music Attenuated a Decrease in Parasympathetic Nervous System Activity after Exercise.
Jia, Tiantian; Ogawa, Yoshiko; Miura, Misa; Ito, Osamu; Kohzuki, Masahiro
2016-01-01
Music and exercise can both affect autonomic nervous system activity. However, the effects of the combination of music and exercise on autonomic activity are poorly understood. Additionally, it remains unknown whether music affects post-exercise orthostatic tolerance. The aim of this study was to evaluate the effects of music on autonomic nervous system activity in orthostatic tolerance after exercise. Twenty-six healthy graduate students participated in four sessions in a random order on four separate days: a sedentary session, a music session, a bicycling session, and a bicycling with music session. Participants were asked to listen to their favorite music and to exercise on a cycle ergometer. We evaluated autonomic nervous system activity before and after each session using frequency analysis of heart rate variability. High frequency power, an index of parasympathetic nervous system activity, was significantly increased in the music session. Heart rate was increased, and high frequency power was decreased, in the bicycling session. There was no significant difference in high frequency power before and after the bicycling with music session, although heart rate was significantly increased. Additionally, both music and exercise did not significantly affect heart rate, systolic blood pressure or also heart rate variability indices in the orthostatic test. These data suggest that music increased parasympathetic activity and attenuated the exercise-induced decrease in parasympathetic activity without altering the orthostatic tolerance after exercise. Therefore, music may be an effective approach for improving post-exercise parasympathetic reactivation, resulting in a faster recovery and a reduction in cardiac stress after exercise.
Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing
2012-04-01
The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics
NASA Astrophysics Data System (ADS)
Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing
2012-04-01
The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment.
CaMKII effects on inotropic but not lusitropic force frequency responses require phospholamban
Wu, Yiming; Luczak, Elizabeth D; Lee, Eun-Jeong; Hidalgo, Carlos; Yang, Jinying; Gao, Zhan; Li, Jingdong; Wehrens, Xander; Granzier, Henk; Anderson, Mark E
2014-01-01
Increasing heart rate enhances cardiac contractility (force frequency relationship, FFR) and accelerates cardiac relaxation (frequency-dependent acceleration of relaxation, FDAR). The positive FFR together with FDAR promotes rapid filling and ejection of blood from the left ventricle (LV) at higher heart rates. Recent studies indicate that the multifunctional Ca2+/calmodulin-dependent protein kinase II (CaMKII) is involved in regulating FFR and FDAR. We used isolated perfused mouse hearts to study the mechanisms of FFR and FDAR in different genetic models, including transgenic myocardial CaMKII inhibition (AC3-I) and phosphalamban knockout (PLN−/−). When the rate was increased from 360 beats/min to 630 beats/min in wild type mouse hearts, the LV developed pressure (LVDP) and the maximum rate of increase in pressure (dP/dt max) increased by 37.6 ± 4.7% and 77.0 ± 8.1%, respectively. However, hearts from AC3-I littermates showed no increase of LVDP and a relatively modest (20.4 ± 3.9 %) increase in dP/dt max. PLN−/− hearts had a negative FFR, and myocardial AC3-I expression did not change the FFR in PLN−/− mice. PLN−/− mouse hearts did not exhibit FDAR, while PLN−/−mice with myocardial AC3-I expression showed further frequency dependent reductions in cardiac relaxation, suggesting CaMKII targets in addition to PLN were critical to myocardial relaxation. We incubated a constitutively active form of CaMKII with chemically-skinned myocardium and found that several myofilament proteins were phosphorylated by CaMKII. However, CaMKII did not affect myofilament calcium sensitivity. Our study shows that CaMKII plays an important role in modulating FFR and FDAR in murine hearts and suggest that PLN is a critical target for CaMKII effects on FFR, while CaMKII effects on FDAR partially require PLN-alternative targets. PMID:22796260
[Autoaggression and pulse rate--a longitudinal study].
Rohmann, U H; Elbing, U; Hartmann, H
1988-12-01
This article presents a model of autoaggressive behavior in which a distinction is made between determining and maintaining factors. Specific environmental, in particular social, and organismic variables are linked to them. The two types of variables interact, thus causing or maintaining autoaggressive behavior. A theory of autoaggression must therefore rely on multicausal/multimodal explanations. A connection between autoaggression and a high level of arousal suggests itself. In this single-case longitudinal study a comparison was made between heart rate and frequency of autoaggressive behavior. High heart rates were found to be correlated with low frequencies of autoaggressive behavior and vice versa. Decreasing autoaggressive behavior was coupled with increasing muscle relaxation and increasing motor activity. However, abnormally high heart rates were associated with both low and high levels of motor activity.
Aksentijević, Dunja; Lewis, Hannah R; Shattock, Michael J
2016-02-01
What is the central question of this study? Rate-pressure product (RPP) is commonly used as an index of cardiac 'effort'. In canine and human hearts (which have a positive force-frequency relationship), RPP is linearly correlated with oxygen consumption and has therefore been widely adopted as a species-independent index of cardiac work. However, given that isolated rodent hearts demonstrate a negative force-frequency relationship, its use in this model requires validation. What is the main finding and its importance? Despite its widespread use, RPP is not correlated with oxygen consumption (or cardiac 'effort') in the Langendorff-perfused isolated rat heart. This lack of correlation was also evident when perfusions included a range of metabolic substrates, insulin or β-adrenoceptor stimulation. Langendorff perfusion of hearts isolated from rats and mice has been used extensively for physiological, pharmacological and biochemical studies. The ability to phenotype these hearts reliably is, therefore, essential. One of the commonly used indices of function is rate-pressure product (RPP); a rather ill-defined index of 'work' or, more correctly, 'effort'. Rate-pressure product, as originally described in dog or human hearts, was shown to be correlated with myocardial oxygen consumption (MV̇O2). Despite its widespread use, the application of this index to rat or mouse hearts (which, unlike the dog or human, have a negative force-frequency relationship) has not been characterized. The aim of this study was to examine the relationship between RPP and MV̇O2 in Langendorff-perfused rat hearts. Paced hearts (300-750 beats min(-1)) were perfused either with Krebs-Henseleit (KH) buffer (11 mm glucose) or with buffer supplemented with metabolic substrates and insulin. The arteriovenous oxygen consumption (MV̇O2) was recorded. Metabolic status was assessed using (31) P magnetic resonance spectroscopy and lactate efflux. Experiments were repeated in the presence of isoprenaline and in unpaced hearts where heart rate was increased by cumulative isoprenaline challenge. In KH buffer-perfused hearts, MV̇O2 increased with increasing heart rate, but given that left ventricular developed pressure decreased with increases in rate, RPP was not correlated with MV̇O2, lactate production or phosphocreatine/ATP ratio. Although the provision of substrates or β-adrenoceptor stimulation changed the shape of the RPP-MV̇O2 relationship, neither intervention resulted in a positive correlation between RPP and oxygen consumption. Rate-pressure product is therefore an unreliable index of oxygen consumption or 'cardiac effort' in the isolated rat heart. © 2015 The Authors. Experimental Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.
Wrist sensor for warfighter status monitor
NASA Astrophysics Data System (ADS)
Chen, Wuping
2000-04-01
There is a pressing need to improve human status monitoring in the medical and military communities. The heart rate and breading rate are the most important human vital signs. The current heart rate and breading rate monitors are rather cumbersome, expensive, and usually confined to the intensive care unit or ambulatory setting. These techniques are therefore unavailable to certain applications, such as home care and military applications. The purpose of this work is to develop new methods and new technologies for heart rate and breathing rate monitoring. To accomplish this task, a novel optical acoustic laser sensor (OALS) is characterized and used to generate an optical signal corresponding to human heart beat and breathing. An application specific integrated circuit (ASIC) is developed for this unique compact human status monitor Extensive experimental data analysis and simulation are conducted to investigate robust digital signal processing (DSP) methods. The Gauss-Hermite wavelet transform (GHWT) is utilized as a time-frequency representative technique to provide a method for the detection of the very low frequency heart rate and breathing rate from the large and noisy biomedical lasergram (BLG) signal. A 915MHz RF transceiver provides a reliable wireless link for the monitor to receive commands or transmit the measurement results to a remote commander center. A complete micro-instrument based on the ideas and methods above are developed and tested. The results show that the heart rate and breathing rate could be measured under difficult environmental situations.
Waring, W S; Rhee, J Y; Bateman, D N; Leggett, G E; Jamie, H
2008-11-01
Antidepressant overdose may be associated with significant cardiotoxicity, and recent data have shown that acute toxic effects are associated with impaired heart rate variability. This study was designed to examine the feasibility of non-invasive heart rate variability recording in patients that present to hospital after deliberate antidepressant ingestion. This was a prospective study of 72 consecutive patients attending the Emergency Department after deliberate antidepressant overdose and 72 age-matched patients that ingested paracetamol, as a control group. Single time-point continuous electrocardiographic recordings were used to allow spectral analyses of heart rate variability determined in low-frequency (LF) and high-frequency (HF) domains. The LF:HF ratio was used to represent overall sympathovagal cardiac activity. Antidepressant overdose was associated with reduced overall heart rate variability: 1329 vs. 2018 ms(2) (P = 0.0239 by Mann-Whitney test). Variability in the LF domain was higher (64.8 vs. 49.8, P = 0.0006), whereas that in the HF domain was lower (24.3 vs. 36.4, P = 0.0001), and the LF:HF ratio was higher in the antidepressant group (2.4 vs. 1.2, P = 0.0003). Antidepressant overdose is associated with impaired heart rate variability in a pattern consistent with excess cardiac sympathetic activity. Further work is required to establish the significance of these findings and to explore whether the impairment of heart rate variability may be used to predict the development of arrhythmia in this patient group.
2014-12-01
cardiovascular diseases. At higher doses, these medications have been prescribed to treat high blood pressure in humans and both may have relevance as...HR, and Tc. § Low frequency (LF) systolic blood pressure variability as an index of sympathetic modulation of vascular tone. § LF and high ... blood pressure variability (LFSYS), LF heart rate variability (LFHR), and high frequency heart rate variability (HFHR) in placebo-, clonidine-, and
Zimmer, M B; Milsom, W K
2001-01-01
To determine whether metabolic rate is suppressed in a temperature-independent fashion in the golden-mantled ground squirrel during steady state hibernation, we measured body temperature and metabolic rate in ground squirrels during hibernation at different T(a)'s. In addition, we attempted to determine whether heart rate, ventilation rate, and breathing patterns changed as a function of body temperature or metabolic rate. We found that metabolic rate changed with T(a) as it was raised from 5 degrees to 14 degrees C, which supports the theory that different species sustain falls in metabolic rate during hibernation in different ways. Heart rate and breathing pattern also changed with changing T(a), while breathing frequency did not. That the total breathing frequency did not correlate closely with oxygen consumption or body temperature, while the breathing pattern did, raises important questions regarding the mechanisms controlling ventilation during hibernation.
NASA Astrophysics Data System (ADS)
Barajas Mauricio, Sánchez; Hernández González, Martha Alicia; Figueroa Vega, Nicte; Malacara Hernández, Juan Manuel; Fraga Teodoro, Córdova
2014-11-01
Introduction: Heart rate variability (HRV) is the cyclic measurement of RR intervals between normal beats. Aim: To determine the VFC via a wireless Polar monitor. Material and methods: 100 symptomatic menopausal women were studied for measurements of HRV were I post a Polar RS400 Watch four hrs. Results: Obtained through the fast Fourier transform, the frequency domain HRV low frequency (LF) 0.04-0.15 Hz, high frequency (HF) 0.15-0.4Hz and the ratio LF / HF. Conclusion: obtaining HRV is important for cardiovascular autonomic assessment in menopausal women.
The effect of 60-h sleep deprivation on cardiovascular regulation and body temperature.
Vaara, Jani; Kyröläinen, Heikki; Koivu, Mikko; Tulppo, Mikko; Finni, Taija
2009-02-01
This study examined cardiovascular regulation and body temperature (BT) during 60 h of sleep deprivation in 20 young healthy cadets. Heart rate variability was measured during an active orthostatic test (AOT). Measurements were performed each day in the morning and evening after 2, 14, 26, 38, 50 and 60 h of sleep deprivation. In AOT, in the sitting and standing positions, heart rate decreased (P < 0.001), while high frequency and low frequency power increased (P < 0.05-0.001) during sleep deprivation. Body temperature also decreased (P < 0.001), but no changes were detected in blood pressure. In conclusion, the accumulation of 60 h of sleep loss resulted in increased vagal outflow, as evidenced by decreased heart rate. In addition, BT decreased during sleep deprivation. Thus, sleep deprivation causes alterations in autonomic regulation of the heart, and in thermoregulation.
Heart Rate Variability During Early Adaptation to Space
NASA Technical Reports Server (NTRS)
Toscano, W. B.; Cowings, P. S.
1994-01-01
A recent report hypothesized that episodes of space motion sickness (SMS) were reliably associated with low frequency oscillations (less than 0.03 to less than 0.01 Hz) in heart rate variability. This paper archives a large data set for review of investigators in this field which may facilitate the evaluation of this hypothesis. Continuous recording of Electro-cardiography (ECG) and other measures were made for 6 to 12 hours per day (waking hours) of six Shuttle crewmembers for the first 3 mission days of two separate Shuttle flights. Spectral analyses of heart rate variability during approximately 200 hours of inflight is presented. In addition, nearly 200 hours of data collected on these same individuals during ground tests prior to the mission are presented. The Purpose of this Publication is to document the incidence of low frequency oscillations of heart rate in 4 people exposed to microgravity over a period of five days. In addition, this report contains spectral analyses of heart rate data collected on these same individuals during ground-based mission simulations. By archiving these data in this manner, it is our intention to make this information available to other investigators interested in studying this phenomena.
Frequency-dependence of the slow force response.
von Lewinski, Dirk; Zhu, Danan; Khafaga, Mounir; Kockskamper, Jens; Maier, Lars S; Hasenfuss, Gerd; Pieske, Burkert
2008-05-01
Stretch induces biphasic inotropic effects in mammalian myocardium. A delayed component (slow force response, SFR) has been demonstrated in various species, however, experimental conditions varied and the underlying mechanisms are controversial. The physiological relevance of the SFR is poorly understood. Experiments were performed in ventricular muscle strips from failing human hearts and non-failing rabbit hearts. Upon stretch, twitch force was assessed at basal conditions (1 Hz, 37 degrees C) and after changing stimulation frequency with and without blockade of the Na+/H+-exchanger-1 (NHE1) or reverse-mode Na+/Ca2+-exchange (NCX). Action potential duration (APD) was assessed using floating electrodes. Low stimulation rates (0.2 Hz) potentiated and higher stimulation rates (2 and 3 Hz) reduced the SFR. The extent of SFR inhibition by NHE1 or NCX inhibition was not affected by stimulation rate. APD decreased at 0.2 Hz but was not altered at higher stimulation rates. The data demonstrate frequency-dependence of the SFR with greater positive inotropic effects at lower stimulation rates. Subcellular mechanisms underlying the SFR are not fundamentally affected by stimulation rate. The SFR may have more pronounced physiological effects at lower heart rates.
Sebastian, Sonia; Ang, Richard; Abramowitz, Joel; Weinstein, Lee S.; Chen, Min; Ludwig, Andreas; Birnbaumer, Lutz
2013-01-01
Reciprocal physiological modulation of heart rate is controlled by the sympathetic and parasympathetic systems acting on the sinoatrial (SA) node. However, there is little direct in vivo work examining the role of stimulatory and inhibitory G protein signaling in the SA node. Thus, we designed a study to examine the role of the stimulatory (Gαs) and inhibitory G protein (Gαi2) in in vivo heart rate regulation in the SA node in the mouse. We studied mice with conditional deletion of Gαs and Gαi2 in the conduction system using cre-loxP technology. We crossed mice in which cre recombinase expression was driven by a tamoxifen-inducible conduction system-specific construct with “Gαs floxed” and “Gαi2 floxed” mice. We studied the heart rate responses of adult mice compared with littermate controls by using radiotelemetry before and after administration of tamoxifen. The mice with conditional deletion of Gαs and Gαi2 had a loss of diurnal variation and were bradycardic or tachycardic, respectively, in the daytime. In mice with conditional deletion of Gαs, there was a selective loss of low-frequency power, while with deletion of Gαi2, there was a loss of high-frequency power in power spectral analysis of heart rate variability. There was no evidence of pathological arrhythmia. Pharmacological modulation of heart rate by isoprenaline was impaired in the Gαs mice, but a muscarinic agonist was still able to slow the heart rate in Gαi2 mice. We conclude that Gαs- and Gαi2-mediated signaling in the sinoatrial node is important in the reciprocal regulation of heart rate through the autonomic nervous system. PMID:23697798
Sebastian, Sonia; Ang, Richard; Abramowitz, Joel; Weinstein, Lee S; Chen, Min; Ludwig, Andreas; Birnbaumer, Lutz; Tinker, Andrew
2013-08-15
Reciprocal physiological modulation of heart rate is controlled by the sympathetic and parasympathetic systems acting on the sinoatrial (SA) node. However, there is little direct in vivo work examining the role of stimulatory and inhibitory G protein signaling in the SA node. Thus, we designed a study to examine the role of the stimulatory (Gαs) and inhibitory G protein (Gαi2) in in vivo heart rate regulation in the SA node in the mouse. We studied mice with conditional deletion of Gαs and Gαi2 in the conduction system using cre-loxP technology. We crossed mice in which cre recombinase expression was driven by a tamoxifen-inducible conduction system-specific construct with "Gαs floxed" and "Gαi2 floxed" mice. We studied the heart rate responses of adult mice compared with littermate controls by using radiotelemetry before and after administration of tamoxifen. The mice with conditional deletion of Gαs and Gαi2 had a loss of diurnal variation and were bradycardic or tachycardic, respectively, in the daytime. In mice with conditional deletion of Gαs, there was a selective loss of low-frequency power, while with deletion of Gαi2, there was a loss of high-frequency power in power spectral analysis of heart rate variability. There was no evidence of pathological arrhythmia. Pharmacological modulation of heart rate by isoprenaline was impaired in the Gαs mice, but a muscarinic agonist was still able to slow the heart rate in Gαi2 mice. We conclude that Gαs- and Gαi2-mediated signaling in the sinoatrial node is important in the reciprocal regulation of heart rate through the autonomic nervous system.
Sleep-mediated heart rate variability after bilateral carotid body tumor resection.
Niemeijer, Nicolasine D; Corssmit, Eleonora P M; Reijntjes, Robert H A M; Lammers, Gert Jan; van Dijk, J Gert; Thijs, Roland D
2015-04-01
The carotid bodies are thought to play an important role in sleep-dependent autonomic changes. Patients who underwent resection of bilateral carotid body tumors have chronically attenuated baroreflex sensitivity. These subjects provide a unique opportunity to investigate the role of the baroreflex during sleep. One-night ambulatory polysomnography (PSG) recording. Participants' homes. Nine patients with bilateral carotid body tumor resection (bCBR) (four women, mean age 50.4 ± 7.2 years) and nine controls matched for age, gender, and body mass index. N/A. Sleep parameters were obtained from PSG. Heart rate (HR) and its variability were calculated using 30-s epochs. In bCBR patients, HR was slightly but not significantly increased during wake and all sleep stages. The effect of sleep on HR was similar for patients and controls. Low frequency (LF) power of the heart rate variability spectrum was significantly lower in bCBR patients in active wakefulness, sleep stage 1 and REM sleep. No differences were found between patients and controls for high frequency (HF) power and the LF/HF ratio. Bilateral carotid body tumor resection (bCBR) is associated with decreased low frequency power during sleep, suggesting impaired baroreflex function. Despite this, sleep-related heart rate changes were similar between bCBR patients and controls. These findings suggest that the effects of sleep on heart rate are predominantly generated through central, non-baroreflex mediated pathways. © 2015 Associated Professional Sleep Societies, LLC.
Physiology responses of Rhesus monkeys to vibration
NASA Astrophysics Data System (ADS)
Hajebrahimi, Zahra; Ebrahimi, Mohammad; Alidoust, Leila; Arabian Hosseinabadi, Maedeh
Vibration is one of the important environmental factors in space vehicles that it can induce severe physiological responses in most of the body systems such as cardiovascular, respiratory, skeletal, endocrine, and etc. This investigation was to assess the effect of different vibration frequencies on heart rate variability (HRV), electrocardiograms (ECG) and respiratory rate in Rhesus monkeys. Methods: two groups of rhesus monkey (n=16 in each group) was selected as control and intervention groups. Monkeys were held in a sitting position within a specific fixture. The animals of this experiment were vibrated on a table which oscillated right and left with sinusoidal motion. Frequency and acceleration for intervention group were between the range of 1 to 2000 Hz and +0.5 to +3 G during 36 weeks (one per week for 15 min), respectively. All of the animals passed the clinical evaluation (echocardiography, sonography, radiography and blood analysis test) before vibration test and were considered healthy and these tests repeated during and at the end of experiments. Results and discussions: Our results showed that heart and respiratory rates increased significantly in response to increased frequency from 1 to 60 Hz (p <0.05) directly with the +G level reaching a maximum (3G) within a seconds compare to controls. There were no significant differences in heart and respiratory rate from 60 t0 2000 Hz among studied groups. All monkeys passed vibration experiment successfully without any arrhythmic symptoms due to electrocardiography analysis. Conclusion: Our results indicate that vibration in low frequency can effect respiratory and cardiovascular function in rhesus monkey. Keywords: Vibration, rhesus monkey, heart rate, respiratory rate
Heart rate variability in normal-weight patients with polycystic ovary syndrome.
Kilit, Celal; Paşalı Kilit, Türkan
2017-05-01
Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.
Autonomic functions in acrocyanosis assessed by heart rate variability
Yılmaz, Sedat; Yokuşoğlu, Mehmet; Çınar, Muhammet; Şimşek, İsmail; Baysan, Oben; Öz, Bilgehan Savaş; Erdem, Hakan; Pay, Salih; Dinç, Ayhan
2014-01-01
Objective To evaluate the autonomic activity of patients with acrocyanosis by using heart rate variability indices. Material and Methods The study group consisted of 24 patients with acrocyanosis and the control group contained 22 sex- and age-matched healthy subjects. All subjects underwent 24-hour Holter monitoring. Among the heart rate variability (HRV) parameters, time-domain and frequency-domain indices were analysed. Results The time-domain indices of HRV indicating global autonomic functions were found to be increased, and indices indicating parasympathetic activity showed a significant decrease in the patient group. Power-spectral analysis of HRV revealed that the low frequency and high frequency power were higher in the patient group than in controls. However, the ratio of Low Frequency/High Frequency was found to be lower in the patient group than in controls. Conclusion In acrocyanosis, both sympathetic and parasympathetic systems seem to be disrupted. Therefore, we may conclude that acrocyanosis may be resulted of systemic autonomic imbalance rather than pure sympathetic over-activation. Also, these results suggest that acrocyanosis is not a localised disorder; on the contrary, it is associated with various abnormalities of the systemic autonomic nervous system. PMID:27708866
The effect of respiratory oscillations in heart rate on detrended fluctuation analysis
NASA Astrophysics Data System (ADS)
Govindan, Rathinaswamy B.; Kota, Srinivas; Al-Shargabi, Tareq; Swisher, Christopher B.; du Plessis, Adre
2017-10-01
Characterization of heart rate using detrended fluctuation analysis (DFA) is impeded by respiratory oscillations. In particular, the short-term exponent measured from 15 to 30 beats is compromised in the DFA. We reconstruct respiratory signal from electrocardiograms and attenuate the respiratory oscillation in the heart rate using a frequency-dependent subtraction approach. We validate this method by applying it to an electrocardiogram signal simulated using a coupled differential equation with the respiratory oscillation modelled using a sine function. The exponent estimated using the proposed approach agreed with the exponent incorporated in the model within a narrow range. In contrast, the exponent obtained from the raw data deviated from the expected value. Furthermore, the exponents obtained for the raw heart rate are smaller than the exponents obtained for the respiration oscillation attenuated heart rate. We apply this approach to heart rate measured from 12 preterm infants that were being treated for prematurity related complications. As observed in the simulated data, we show that compared to the raw heart rate, the respiratory oscillation attenuated heart rate shows higher short-term exponent (p < 0.001).
NASA Technical Reports Server (NTRS)
Brenner, Malcolm; Shipp, Thomas
1988-01-01
In a study of the validity of eight candidate voice measures (fundamental frequency, amplitude, speech rate, frequency jitter, amplitude shimmer, Psychological Stress Evaluator scores, energy distribution, and the derived measure of the above measures) for determining psychological stress, 17 males age 21 to 35 were subjected to a tracking task on a microcomputer CRT while parameters of vocal production as well as heart rate were measured. Findings confirm those of earlier studies that increases in fundamental frequency, amplitude, and speech rate are found in speakers involved in extreme levels of stress. In addition, it was found that the same changes appear to occur in a regular fashion within a more subtle level of stress that may be characteristic, for example, of routine flying situations. None of the individual speech measures performed as robustly as did heart rate.
Costa, Rui Miguel; Brody, Stuart
2012-01-01
Resting heart rate variability (HRV), a marker of parasympathetic activity, is a predictor of health and longevity. Better erectile function is associated with greater resting HRV (assessed by high frequency power [HF]), and in both sexes, penile-vaginal intercourse (PVI) is the only sexual behavior consistently associated with indices of better physical and mental health, including greater resting HRV (assessed by standard deviation [SD] of heart rate [HR]). To examine the hypotheses that greater frequency of orgasms attained through PVI (for women, without additional simultaneous clitoral stimulation; vaginal orgasm) are associated with greater resting HRV. A differential hypothesis is that HRV measures will be unrelated to orgasmic frequency from noncoital sexual activities. Coitally experienced men and women (N = 143) had their heart rate measured for 5 minutes and reported the frequency of various sexual behaviors and corresponding orgasms in a recent representative month. Partial correlations and analyses of covariance controlling for social desirability responding were used to examine the associations of sexual activities with time and frequency domains of HRV. For men, greater resting SD of HR was associated with greater PVI orgasm frequency. For women, greater resting SD of HR was associated with any vaginal orgasm. These findings remained after controlling for cohabitation. Sexual activities were unrelated to HF. Lifetime number of PVI partners was unrelated to SD of HR and HF. Findings are discussed in the context of orgasms through PVI enhancing HRV, and greater parasympathetic tone favoring the capacity to engage in PVI, and in the case of women, to reach vaginal orgasm. The possibility of healthier people having greater resting HRV and more frequent orgasms through specifically PVI is also considered. © 2011 International Society for Sexual Medicine.
Radtke, Thomas; Poerschke, Daniel; Wilhelm, Matthias; Trachsel, Lukas D; Tschanz, Hansueli; Matter, Friederike; Jauslin, Daniel; Saner, Hugo; Schmid, Jean-Paul
2016-04-01
The haemodynamic response to Finnish sauna and subsequent cold-water immersion in heart failure patients is unknown. Haemodynamic response to two consecutive Finnish sauna (80℃) exposures, followed by a final head-out cold-water immersion (12℃) was measured in 37 male participants: chronic heart failure (n = 12, 61.8 ± 9.2 years), coronary artery disease (n = 13, 61.2 ± 10.6 years) and control subjects (n = 12, 60.9 ± 8.9 years). Cardiac output was measured non-invasively with an inert gas rebreathing method prior to and immediately after the first sauna exposure and after cold-water immersion, respectively. Blood pressure was measured before, twice during and after sauna. The autonomic nervous system was assessed by power spectral analysis of heart rate variability. Total power, low-frequency and high-frequency components were evaluated. The low frequency/high frequency ratio was used as a marker of sympathovagal balance. Sauna and cold-water immersion were well tolerated by all subjects. Cardiac output and heart rate significantly increased in all groups after sauna and cold-water immersion (p < 0.05), except for coronary artery disease patients after sauna exposure. Systolic blood pressure during sauna decreased significantly in all groups with a nadir after 6 min (all p < 0.05). Cold-water immersion significantly increased systolic blood pressure in all groups (p < 0.05). No change in the low/high frequency ratio was found in chronic heart failure patients. In coronary artery disease patients and controls a prolonged increase in low frequency/high frequency ratio was observed after the first sauna exposure. Acute exposure to Finnish sauna and cold-water immersion causes haemodynamic alterations in chronic heart failure patients similarly to control subjects and in particular did not provoke an excessive increase in adrenergic activity or complex arrhythmias. © The European Society of Cardiology 2015.
Campos, Filippe V; Neves, Laura M; Da Silva, Vinicius Z; Cipriano, Graziella F; Chiappa, Gaspar R; Cahalin, Lawrence; Arena, Ross; Cipriano, Gerson
2016-05-01
To determine the immediate effects of transcutaneous electrical nerve stimulation (TENS) on heart rate, systolic blood pressure (SBP), and diastolic blood pressure (DBP) in apparently healthy adults (age ≥18y). The Cochrane Library (online version 2014), PubMed (1962-2014), EMBASE (1980-2014), and LILACS (1980-2014) electronic databases were searched. Randomized controlled trials were included when TENS was administered noninvasively with surface electrodes during rest, and the effect of TENS was compared with that of control or placebo TENS. A sensitive search strategy for identifying randomized controlled trials was used by 2 independent reviewers. The initial search led to the identification of 432 studies, of which 5 articles met the eligibility criteria. Two independent reviewers extracted data from the selected studies. Quality was evaluated using the PEDro scale. Mean differences or standardized mean differences in outcomes were calculated. Five eligible articles involved a total of 142 apparently healthy individuals. Four studies used high-frequency TENS and 3 used low-frequency TENS and evaluated the effect on SBP. Three studies using high-frequency TENS and 2 using low-frequency TENS evaluated the effect on DBP. Three studies using high-frequency TENS and 1 study using low-frequency TENS evaluated the effect on heart rate. A statistically significant reduction in SBP (-3.00mmHg; 95% confidence interval [CI], -5.02 to -0.98; P=.004) was found using low-frequency TENS. A statistically significant reduction in DBP (-1.04mmHg; 95% CI, -2.77 to -0.03; I(2)=61%; P=.04) and in heart rate (-2.55beats/min; 95% CI, -4.31 to -0.78; I(2)=86%; P=.005]) was found using both frequencies. The median value on the PEDro scale was 7 (range, 4-8). TENS seems to promote a discrete reduction in SBP, DBP, and heart rate in apparently healthy individuals. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Tegeler, Charles H; Shaltout, Hossam A; Tegeler, Catherine L; Gerdes, Lee; Lee, Sung W
2015-06-01
Explore potential use of a temporal lobe electrical asymmetry score to discriminate between sympathetic and parasympathetic tendencies in autonomic cardiovascular regulation. 131 individuals (82 women, mean age 43.1, range 13-83) with diverse clinical conditions completed inventories for depressive (CES-D or BDI-II) and insomnia-related (ISI) symptomatology, and underwent five-minute recordings of heart rate and blood pressure, allowing calculation of heart rate variability and baroreflex sensitivity (BRS), followed by one-minute, two-channel, eyes-closed scalp recordings of brain electrical activity. A temporal lobe high-frequency (23-36 Hz) electrical asymmetry score was calculated for each subject by subtracting the average amplitude in the left temporal region from amplitude in the right temporal region, and dividing by the lesser of the two. Depressive and insomnia-related symptomatology exceeding clinical threshold levels were reported by 48% and 50% of subjects, respectively. Using a cutoff value of 5% or greater to define temporal high-frequency asymmetry, subjects with leftward compared to rightward asymmetry were more likely to report use of a sedative-hypnotic medication (42% vs. 22%, P = 0.02). Among subjects with asymmetry of 5% or greater to 30% or greater, those with rightward compared to leftward temporal high-frequency asymmetry had higher resting heart rate (≥5% asymmetry, 72.3 vs. 63.8, P = 0.004; ≥10%, 71.5 vs. 63.0, P = 0.01; ≥20%, 72.2 vs. 64.2, P = 0.05; ≥30%, 71.4 vs. 64.6, P = 0.05). Subjects with larger degrees of rightward compared to leftward temporal high-frequency asymmetry had lower baroreflex sensitivity (≥40% asymmetry, 10.6 vs. 16.4, P = 0.03; ≥50% asymmetry, 10.4 vs. 16.7, P = 0.05). In a heterogeneous population, individuals with rightward compared to leftward temporal high-frequency electrical asymmetry had higher resting heart rate and lower BRS. Two-channel recording of brain electrical activity from bilateral temporal regions appears to hold promise for further investigation as a means to assess cortical activity associated with autonomic cardiovascular regulation.
Sequential Analysis of Autonomic Arousal and Self-Injurious Behavior
ERIC Educational Resources Information Center
Hoch, John; Symons, Frank; Sng, Sylvia
2013-01-01
There have been limited direct tests of the hypothesis that self-injurious behavior (SIB) regulates arousal. In this study, two autonomic biomarkers for physiological arousal (heart rate [HR] and the high-frequency [HF] component of heart rate variability [HRV]) were investigated in relation to SIB for 3 participants with intellectual…
Heart-rate variability and precompetitive anxiety in swimmers.
Cervantes Blásquez, Julio César; Rodas Font, Gil; Capdevila Ortís, Lluís
2009-11-01
The aim of this study was to test the utility of heart-rate variability (HRV) analyses as a noninvasive means of quantifying cardiac autonomic regulation during precompetitive anxiety situations in swimmers. Psychophysiological state evaluation of 10 volunteer
Rubik, Beverly
2017-01-01
This study investigated whether short-term exposure to a passive online software application of purported subtle energy technology would affect heart rate variability (HRV) and associated autonomic nervous system measures. This was a randomized, double-blinded, sham-controlled clinical trial (RCT). The study took place in a nonprofit laboratory in Emeryville, California. Twenty healthy, nonsmoking subjects (16 females), aged 40-75 years, participated. Quantum Code Technology ™ (QCT), a purported subtle energy technology, was delivered through a passive software application (Heart+ App) on a smartphone placed <1 m from subjects who were seated and reading a catalog. HRV was measured for 5 min in triplicate for each condition via finger plethysmography using a Food and Drug Administration medically approved HRV measurement device. Measurements were made at baseline and 35 min following exposure to the software applications. The following parameters were calculated and analyzed: heart rate, total power, standard deviation node-to-node, root mean square sequential difference, low frequency to high frequency ratio (LF/HF), low frequency (LF), and high frequency (HF). Paired samples t-tests showed that for the Heart+ App, mean LF/HF decreased (p = 9.5 × 10 -4 ), while mean LF decreased in a trend (p = 0.06), indicating reduced sympathetic dominance. Root mean square sequential difference increased for the Heart+ App, showing a possible trend (p = 0.09). Post-pre differences in LF/HF for sham compared with the Heart+ App were also significant (p < 0.008) by independent t-test, indicating clinical relevance. Significant beneficial changes in mean LF/HF, along with possible trends in mean LF and root mean square sequential difference, were observed in subjects following 35 min exposure to the Heart+ App that was working in the background on an active smartphone untouched by the subjects. This may be the first RCT to show that specific frequencies of a purported non-Hertzian type of subtle energy conveyed by software applications broadcast from personal electronic devices can be bioactive and beneficially impact autonomic nervous system balance.
Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity.
Jarchi, Delaram; Casson, Alexander J
2017-09-01
Recently numerous methods have been proposed for estimating average heart rate using photoplethysmography (PPG) during physical activity, overcoming the significant interference that motion causes in PPG traces. We propose a new algorithm framework for extracting instantaneous heart rate from wearable PPG and Electrocardiogram (ECG) signals to provide an estimate of heart rate variability during exercise. For ECG signals, we propose a new spectral masking approach which modifies a particle filter tracking algorithm, and for PPG signals constrains the instantaneous frequency obtained from the Hilbert transform to a region of interest around a candidate heart rate measure. Performance is verified using accelerometry and wearable ECG and PPG data from subjects while biking and running on a treadmill. Instantaneous heart rate provides more information than average heart rate alone. The instantaneous heart rate can be extracted during motion to an accuracy of 1.75 beats per min (bpm) from PPG signals and 0.27 bpm from ECG signals. Estimates of instantaneous heart rate can now be generated from PPG signals during motion. These estimates can provide more information on the human body during exercise. Instantaneous heart rate provides a direct measure of vagal nerve and sympathetic nervous system activity and is of substantial use in a number of analyzes and applications. Previously it has not been possible to estimate instantaneous heart rate from wrist wearable PPG signals.
Frequency and duration of interval training programs and changes in aerobic power
NASA Technical Reports Server (NTRS)
Fox, E. L.; Bartels, R. L.; Obrien, R.; Bason, R.; Mathews, D. K.; Billings, C. E.
1975-01-01
The present study was designed to ascertain whether a training frequency of 2 days/wk for a 7- and 13-wk interval training program would produce improvement in maximal aerobic power comparable to that obtained from 7- and 13-wk programs of the same intensity consisting of 4 training days/wk. After training, there was a significant increase in maximal aerobic power that was independent of both training frequency and duration. Maximal heart rate was significantly decreased following training. Submaximal aerobic power did not change with training, but submaximal heart rate decreased significantly with greater decreases the more frequent and the longer the training.
Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K
2018-03-01
Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P < 0.001. There were no such differences for turbulence slope (Ts). In the 24-hour analysis almost all heart rate variability parameters were significantly lower in the systemic lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R = 0.464; P < 0.05, a negative correlation between low/high frequency ratio and r-MSSD, R = -0.454; P < 0.05; p50NN, R = -0.435; P < 0.05 and high frequency, R = -0.478; P < 0.05. In contrast, there was no statistically significant correlation between heart rate turbulence and other variables evaluated, including disease duration and the type of autoantibodies. Our study confirms the presence of autonomic disorders with respect to both heart rate variability and heart rate turbulence parameters and the presence of diurnal disturbances of sympathetic-parasympathetic balance. Further studies are required.
Evaluation of heart rate variability indices using a real-time handheld remote ECG monitor.
Singh, Swaroop S; Carlson, Barbara W; Hsiao, Henry S
2007-12-01
Studies on retrospective electrocardiogram (ECG) recordings of patients during cardiac arrest have shown significant changes in heart rate variability (HRV) indices prior to the onset of cardiac arrhythmia. The early detection of these changes in HRV indices increases the chances for a successful medical intervention by increasing the response time window. A portable, handheld remote ECG monitor designed in this research detects the QRS complex and calculates short-term HRV indices in real-time. The QRS detection of the ECG recordings of subjects from the MIT-Arrhythmia database yielded a mean sensitivity of 99.34% and a specificity of 99.31%. ECG recordings from normal subjects and subjects with congestive heart failure were used to identify the differences in HRV indices. An increase in heart rate, high-frequency spectral power (HFP), total spectral power, the ratio of HFP to low-frequency spectral power (LFP), and a decrease in root mean square sum of RR differences were observed. No difference was found on comparison of the standard deviation of normal to normal interval between adjacent R-waves, LFP, and very-low-frequency spectral power. Based on these, additional analytical calculations could be made to provide early warnings of impending cardiac conditions.
Hamer, Mark; Boutcher, Yati N; Boutcher, Stephen H
2005-12-01
This study examined differentiated rating of perceived exertion (RPE), heart rate, and heart-rate variability during light cycle ergometry exercise at two different pedal rates. 30 healthy men (22.6 +/- 0.9 yr.) were recruited from a student population and completed a continuous 20-min. cycle ergometry exercise protocol, consisting of a 4-min. warm-up (60 rev./min., 30 Watts), followed by four bouts of 4 min. at different combinations of pedal rate (40 or 80 rev./min.) and power output (40 or 80 Watts). The order of the four combinations was counterbalanced across participants. Heart rate was measured using a polar heart-rate monitor, and parasympathetic balance was assessed through time series analysis of heart-rate variability. Measures were compared using a 2 (pedal rate) x 2 (power output) repeated-measures analysis of variance. RPE was significantly greater (p<.05) at 80 versus 40 rev./min. at 40 W. For both power outputs heart rate was significantly increased, and the high frequency component of heart-rate variability was significantly reduced at 80 compared with 40 rev./min. These findings indicate the RPE was greater at higher than at lower pedalling rates for a light absolute power output which contrasts with previous findings based on use of higher power output. Also, pedal rate had a significant effect on heart rate and heart-rate variability at constant power output.
Lin, Yu-Ting; Wu, Hau-Tieng
2017-01-01
Heart rate variability (HRV) offers a noninvasive way to peek into the physiological status of the human body. When this physiological status is dynamic, traditional HRV indices calculated from power spectrum do not resolve the dynamic situation due to the issue of nonstationarity. Clinical anesthesia is a typically dynamic situation that calls for time-varying HRV analysis. Concentration of frequency and time (ConceFT) is a nonlinear time-frequency (TF) analysis generalizing the multitaper technique and the synchrosqueezing transform. The result is a sharp TF representation capturing the dynamics inside HRV. Companion indices of the commonly applied HRV indices, including time-varying low-frequency power (tvLF), time-varying high-frequency power, and time-varying low-high ratio, are considered as measures of noxious stimulation. To evaluate the feasibility of the proposed indices, we apply these indices to study two different types of noxious stimulation, the endotracheal intubation and surgical skin incision, under general anesthesia. The performance was compared with traditional HRV indices, the heart rate reading, and indices from electroencephalography. The results indicate that the tvLF index performs best and outperforms not only the traditional HRV index, but also the commonly used heart rate reading. With the help of ConceFT, the proposed HRV indices are potential to provide a better quantification of the dynamic change of the autonomic nerve system. Our proposed scheme of time-varying HRV analysis could contribute to the clinical assessment of analgesia under general anesthesia.
Air pollution and heart rate variability: effect modification by chronic lead exposure.
Park, Sung Kyun; O'Neill, Marie S; Vokonas, Pantel S; Sparrow, David; Wright, Robert O; Coull, Brent; Nie, Huiling; Hu, Howard; Schwartz, Joel
2008-01-01
Outdoor air pollution and lead exposure can disturb cardiac autonomic function, but the effects of both these exposures together have not been studied. We examined whether higher cumulative lead exposures, as measured by bone lead, modified cross-sectional associations between air pollution and heart rate variability among 384 elderly men from the Normative Aging Study. We used linear regression, controlling for clinical, demographic, and environmental covariates. We found graded, significant reductions in both high-frequency and low-frequency powers of heart rate variability in relation to ozone and sulfate across the quartiles of tibia lead. Interquartile range increases in ozone and sulfate were associated respectively, with 38% decrease (95% confidence interval = -54.6% to -14.9%) and 22% decrease (-40.4% to 1.6%) in high frequency, and 38% decrease (-51.9% to -20.4%) and 12% decrease (-28.6% to 9.3%) in low frequency, in the highest quartile of tibia lead after controlling for potential confounders. We observed similar but weaker effect modification by tibia lead adjusted for education and cumulative traffic (residuals of the regression of tibia lead on education and cumulative traffic). Patella lead modified only the ozone effect on heart rate variability. People with long-term exposure to higher levels of lead may be more sensitive to cardiac autonomic dysfunction on high air pollution days. Efforts to understand how environmental exposures affect the health of an aging population should consider both current levels of pollution and history of lead exposure as susceptibility factors.
Gay, Estelle; Bornallet, Géraldine; Gaucherand, Pascal; Doret, Muriel
2015-11-01
To assess if the fetal electrocardiogram especially ST segment is modified by congenital heart diseases: modifications in frequencies of the different ST events and modifications in signal quality. A retrospective case-control study, comparing frequencies of the different ST events and the quality of the signal between fetuses with congenital heart diseases and fetuses without congenital heart disease. From 2000 to 2011, fifty-eight fetuses with congenital heart disease had their heart rate recording using a STAN device during labor. Control group was fetuses who were born just before a case and had a STAN as a second line for intrapartum surveillance. Cases and controls were matched on parity, gestational age at birth, presence of growth restriction and umbilical artery pH. Frequencies of the different ST event and quality of the signal were first analyzed for the global labor recording, and then separately for the first and the second phase of labor. No statistically significant difference in ST event frequencies between fetuses with congenital heart disease and the control group was found. Regarding the quality of the signal, 11.49% (±18.82) of recording time is a signal loss for fetus with congenital heart disease whereas only 5.18% (±10.67) for the control group (p=0.028). This is the first study investigating for intrapartum electrocardiogram modification in fetus with congenital heart disease. Congenital heart diseases do not modify frequencies of ST events. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ponomarenko, V. I.; Prokhorov, M. D.; Karavaev, A. S.; Kiselev, A. R.; Gridnev, V. I.; Bezruchko, B. P.
2013-10-01
We investigate synchronization between the low-frequency oscillations of heart rate and blood pressure having in humans a basic frequency close to 0.1 Hz. A quantitative estimation of this synchronization based on calculation of relative time of phase synchronization of oscillations is proposed. We show that assessment of synchronization between the considered oscillations can be useful for selecting an optimal dose of beta-blocker treatment in patients after acute myocardial infarction. It is found out that low value of synchronization between the low-frequency rhythms in heart rate and blood pressure at the first week after acute myocardial infarction is a sensitive marker of high risk of mortality during the subsequent 5 years.
Effect of HeartMate left ventricular assist device on cardiac autonomic nervous activity.
Kim, S Y; Montoya, A; Zbilut, J P; Mawulawde, K; Sullivan, H J; Lonchyna, V A; Terrell, M R; Pifarré, R
1996-02-01
Clinical performance of a left ventricular assist device is assessed via hemodynamic parameters and end-organ function. This study examined effect of a left ventricular assist device on human neurophysiology. This study evaluated the time course change of cardiac autonomic activity of 3 patients during support with a left ventricular assist device before cardiac transplantation. Cardiac autonomic activity was determined by power spectral analysis of short-term heart rate variability. The heart rate variability before cardiac transplantation was compared with that on the day before left ventricular assist device implantation. The standard deviation of the mean of the R-R intervals of the electrocardiogram, an index of vagal activity, increased to 27 +/- 7 ms from 8 +/- 0.6 ms. The modulus of power spectral components increased. Low frequency (sympathetic activity) and high frequency power (vagal activity) increased by a mean of 9 and 22 times of each baseline value (low frequency power, 5.2 +/- 3.0 ms2; high frequency power, 2.1 +/- 0.7 ms2). The low over high frequency power ratio decreased substantially, indicating an improvement of cardiac sympatho-vagal balance. The study results suggest that left ventricular assist device support before cardiac transplantation may exert a favorable effect on cardiac autonomic control in patients with severe heart failure.
Park, Sung Wook; Brenneman, Michael; Cooke, William H; Cordova, Alberto; Fogt, Donovan
The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric's "threshold". The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the "threshold" for the metrics of interest were compared using correlation analysis and paired-sample t -test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics' threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.
Boudet, Gil; Walther, Guillaume; Courteix, Daniel; Obert, Philippe; Lesourd, Bruno; Pereira, Bruno; Chapier, Robert; Vinet, Agnès; Chamoux, Alain; Naughton, Geraldine; Poirier, Paul; Dutheil, Frédéric
2017-02-01
Aims To analyse the effects of different modalities of exercise training on heart rate variability (HRV) in individuals with metabolic syndrome (MetS). Methods and results Eighty MetS participants (aged 50-70 years) were housed and managed in an inpatient medical centre for 21 days, including weekends. Physical activity and food intake/diet were intensively monitored. Participants were randomly assigned into three training groups, differing only by intensity of exercise: moderate-endurance-moderate-resistance ( re), high-resistance-moderate-endurance ( Re), and moderate-resistance-high-endurance ( rE). HRV was recorded before and after the intervention by 24-hour Holter electrocardiogram. Although mean 24-hour heart rate decreased more in Re than re (-11.6 ± 1.6 vs. -4.8 ± 2.1%; P = 0.010), low frequency/high frequency decreased more in re than Re (-20.4 ± 5.5% vs. + 20.4 ± 9.1%; P = 0.002) and rE (-20.4 ± 5.5% vs. -0.3 ± 11.1%; P = 0.003). Very low frequency increased more in Re than re (+121.2 ± 35.7 vs. 42.9 ± 11.3%; P = 0.004). For all HRV parameters, rE ranged between re and Re values. Low frequency/high frequency changes were linked with visceral fat loss only in re (coefficient 5.9, 95% CI 1.9-10.0; P = 0.004). By day 21, HRV parameters of MetS groups (heart rate -8.6 ± 1.0%, standard deviation of R-R intervals + 34.0 ± 6.6%, total power + 63.3 ± 11.1%; P < 0.001) became closer to values of 50 aged-matched healthy controls. Conclusions A 3-week residential programme with intensive volumes of physical activity (15-20 hours per week) enhanced HRV in individuals with MetS. Participants with moderate intensity of training had greater improvements in sympathovagal balance, whereas those with high intensity in resistance training had greater decreases in heart rate and greater increases in very low frequency. Modality-specific relationships were observed between enhanced HRV and visceral fat loss. Clinical Trial Registration URL: http://www.clinicaltrials.gov . Unique identifier: NCT00917917.
Hemorheology and heart rate variability in patients with diabetes mellitus type 2.
Velcheva, Irena; Damianov, Petar; Mantarova, Stefka; Antonova, Nadia
2011-01-01
Our study aimed to investigate the relationship between hemorheological parameters and heart rate variability (HRV) in patients with diabetes mellitus type 2. Hemorheological variables, including hematocrit (Ht), fibrinogen (Fib), whole blood (WBV) and plasma viscosity (PV) at shear rates of 0.0237 s(-1) to 128.5 s(-1) were examined in 20 patients with diabetes mellitus type 2 and in 10 control subjects. They all underwent non-invasive short-term monitoring of heart rate at rest and after passive head-up tilt. Measurement of the R-R intervals and calculation of the time domain parameters and the power spectral data were performed by our softwear, using fast Fourier transformation. Significant increase of Fib and WBV in the patients in comparison to controls was found within the range of shear rates 0.0237 s(-1) to 128.5 s(-1). In the diabetic patients parallel decrease of the total power (TP), the low frequency spectral power (LF) and of the mean RR and mild increase of the low frequency-high frequency ratio (LF/HF) at rest were established. This tendency was kept after the passive tilt. In patients with diabetes mellitus type 2 the increased blood viscosity was associated with reduced HRV.
Effects of intranasal oxytocin on social anxiety in males with fragile X syndrome.
Hall, Scott S; Lightbody, Amy A; McCarthy, Brigid E; Parker, Karen J; Reiss, Allan L
2012-04-01
Fragile X syndrome (FXS) is a rare inherited genetic disorder causing severe intellectual disability and autistic-like symptoms. Individuals with FXS, males in particular, often exhibit extreme eye gaze avoidance and hyperarousal when they encounter stressful social situations. We investigated whether oxytocin (OT), a hormone with prosocial and anxiolytic effects, could alleviate symptoms of social anxiety in this population. A randomized double-blind placebo-controlled single-dose trial was performed with intranasal administration of placebo, 24 IU OT and 48 IU OT. Measures of eye gaze frequency, heart rate, respiratory sinus arrhythmia (RSA), heart rate variability (HRV) and salivary cortisol were obtained during a structured social challenge conducted 50 min following OT administration. Ten low-functioning males with FXS (aged 13-28 years) traveled to Stanford for the initial visit: 8 completed the study. Eye gaze frequency improved significantly in response to the 24 IU OT dose and salivary cortisol levels decreased significantly in response to the 48 IU OT dose. There was no effect of OT on heart rate, RSA or HRV although individual plots of the heart rate data suggested that OT increased heart rate in some participants and decreased heart rate in others. These findings suggest that intranasal administration of OT may ameliorate some symptoms of social anxiety in patients with FXS. Further double-blind placebo-controlled studies of OT, conducted in combination with behavioral treatment programs, may be warranted. Copyright © 2011 Elsevier Ltd. All rights reserved.
Musaeva, Z A; Khaspekova, N B; Veĭn, A M
2001-01-01
Physiological changes accompanying syncopes of neural origin (SNO) in patients with psychovegetative syndrome are still insufficiently studied. The data concerning the role of the autonomic nervous system are discrepant. Heart rate variability was analyzed in 68 patients with SNO in a supine position and during the active 20-min orthostatic test taking into account the heart rate components of very low frequency (VLF, an index of cerebral sympathetic activity) and high frequency (HF, a marker of vagal modulation). Steady growth of the VLF and progressive decrease in the LF within 15-20 min of the orthostasis were observed in all the patients (n = 33), who fainted after this period. The predominance of the VLF in the heart rate power spectra was correlated with a high level of anxiety. It is suggested that this fact indicates the stable cerebral sympathetic activation resulting in a baroreceptor dysfunction, i.e., a failure of vasomotor regulation in patients with SNO.
Patterson, Jae T; Hart, Amanda; Hansen, Steve; Carter, Michael J; Ditor, David
2016-04-01
Heart rate variability (i.e., low frequency:high frequency ratio) was measured to differentiate invested cognitive effort during the acquisition and retention of a novel task. Participants (12 male, M = 25.1 year, SD = 3.6; 12 female, M = 22.8 year, SD = 1.1) were required to produce Braille equivalents of English letter primes on a standardized keyboard in proactive or retroactive conditions (groups, each n = 12). The correct Braille response was either provided before (i.e., proactively) or after (i.e., retroactively) the participant's response. During acquisition, participants in the proactive group demonstrated shorter study time, greater recall success, and reported lower cognitive investment. Participants in the proactive and retroactive groups did not statistically differ in heart rate variability. For retention, the retroactive group showed greater recall success, lower perceived cognitive effort investment, and lower heart rate variability. The results highlight the usefulness of heart rate variability in discriminating the cognitive effort invested for a recently acquired skill. © The Author(s) 2016.
Oosting, J; Struijker-Boudier, H A; Janssen, B J
1997-04-01
To examine the influence of the autonomic nervous system on ultradian and circadian rhythms of blood pressure, heart rate and baroreflex sensitivity of heart rate (BRS) in spontaneously hypertensive rats (SHR). Spontaneous fluctuations in blood pressure, heart rate and BRS in SHR were recorded continuously for 24 h using a computerized system and compared with those in Wistar-Kyoto (WKY) rats. Furthermore, 24 h recordings were performed in SHR during cardiac autonomic blockade by metoprolol and methyl-atropine, vascular autonomic blockade by prazosin, ganglionic blockade by hexamethonium and vagal stimulation by a low dose of scopolamine. The magnitudes of the ultradian fluctuations in blood pressure, heart rate and BRS were assessed by wide-band spectral analysis techniques. The BRS was lower in SHR than it was in WKY rats throughout the 24 h cycle. In both strains high values were found during the light, resting period, whereas low values were found during the first hours of the dark, active period. The circadian rhythmicity of the blood pressure in SHR was abolished completely during the infusions of prazosin and hexamethonium. In contrast, the circadian rhythmicities of the blood pressure and heart rate were not altered by infusions of metoprolol, methyl-atropine and the low dose of scopolamine. Power spectra of the blood pressure and heart rate lacked predominant peaks at ultradian frequencies and showed 1/f characteristics. In the absence of autonomic tone, the ultradian fluctuations in heart rate, but not in blood pressure, were decreased. The ultradian BRS spectra had no 1/f shape, but showed a major peak at approximately equal to 20 min for 71% of the WKY rats and 42% of the SHR. The influence of the autonomic nervous system on the blood pressure and heart rats in SHR is frequency-dependent. The circadian, but not ultradian, blood pressure rhythmicity is controlled by vascular autonomic activity. Conversely, the circadian, but not ultradian, heart rate rhythmicity is independent of autonomic tone. In rats, just as in humans, the trough in baroreflex sensitivity occurred after the sleeping period, when locomotor activity is resumed.
Ludyga, Sebastian; Gerber, Markus; Mücke, Manuel; Brand, Serge; Weber, Peter; Brotzmann, Mark; Pühse, Uwe
2018-02-01
To investigate cognitive flexibility and task-related heart rate variability following moderately intense aerobic exercise and after watching a video in both children with ADHD and healthy controls. Using a cross-over design, participants completed cognitive assessments following exercise and a physically inactive control condition. Behavioral performance was assessed using the Alternate Uses task. Heart rate variability was recorded via electrocardiography during the cognitive task. The statistical analysis revealed that in comparison with the control condition, both groups showed higher cognitive flexibility following aerobic exercise. Moreover, decreased low frequency and high frequency power was observed in the exercise condition. The findings suggest that exercise elicits similar benefits for cognitive flexibility in children with ADHD and healthy controls, partly due to an increase in arousal induced by parasympathetic withdrawal.
Haizlip, Kaylan M; Milani-Nejad, Nima; Brunello, Lucia; Varian, Kenneth D; Slabaugh, Jessica L; Walton, Shane D; Gyorke, Sandor; Davis, Jonathan P; Biesiadecki, Brandon J; Janssen, Paul M L
2015-01-01
As the heart transitions from one exercise intensity to another, changes in cardiac output occur, which are modulated by alterations in force development and calcium handling. Although the steady-state force-calcium relationship at various heart rates is well investigated, regulation of these processes during transitions in heart rate is poorly understood. In isolated right ventricular muscle preparations from the rabbit, we investigated the beat-to-beat alterations in force and calcium during the transition from one stimulation frequency to another, using contractile assessments and confocal microscopy. We show that a change in steady-state conditions occurs in multiple phases: a rapid phase, which is characterized by a fast change in force production mirrored by a change in calcium transient amplitude, and a slow phase, which follows the rapid phase and occurs as the muscle proceeds to stabilize at the new frequency. This second/late phase is characterized by a quantitative dissociation between the calcium transient amplitude and developed force. Twitch timing kinetics, such as time to peak tension and 50% relaxation rate, reached steady-state well before force development and calcium transient amplitude. The dynamic relationship between force and calcium upon a switch in stimulation frequency unveils the dynamic involvement of myofilament-based properties in frequency-dependent activation.
Synchrosqueezing an effective method for analyzing Doppler radar physiological signals.
Yavari, Ehsan; Rahman, Ashikur; Jia Xu; Mandic, Danilo P; Boric-Lubecke, Olga
2016-08-01
Doppler radar can monitor vital sign wirelessly. Respiratory and heart rate have time-varying behavior. Capturing the rate variability provides crucial physiological information. However, the common time-frequency methods fail to detect key information. We investigate Synchrosqueezing method to extract oscillatory components of the signal with time varying spectrum. Simulation and experimental result shows the potential of the proposed method for analyzing signals with complex time-frequency behavior like physiological signals. Respiration and heart signals and their components are extracted with higher resolution and without any pre-filtering and signal conditioning.
Heart Rate Detection During Sleep Using a Flexible RF Resonator and Injection-Locked PLL Sensor.
Kim, Sung Woo; Choi, Soo Beom; An, Yong-Jun; Kim, Byung-Hyun; Kim, Deok Won; Yook, Jong-Gwan
2015-11-01
Novel nonintrusive technologies for wrist pulse detection have been developed and proposed as systems for sleep monitoring using three types of radio frequency (RF) sensors. The three types of RF sensors for heart rate measurement on wrist are a flexible RF single resonator, array resonators, and an injection-locked PLL resonator sensor. To verify the performance of the new RF systems, we compared heart rates between presleep time and postsleep onset time. Heart rates of ten subjects were measured using the RF systems during sleep. All three RF devices detected heart rates at 0.2 to 1 mm distance from the skin of the wrist over clothes made of cotton fabric. The wrist pulse signals of a flexible RF single resonator were consistent with the signals obtained by a portable piezoelectric transducer as a reference. Then, we confirmed that the heart rate after sleep onset time significantly decreased compared to before sleep. In conclusion, the RF system can be utilized as a noncontact nonintrusive method for measuring heart rates during sleep.
Numerical modeling of dynamics of heart rate and arterial pressure during passive orthostatic test
NASA Astrophysics Data System (ADS)
Ishbulatov, Yu. M.; Kiselev, A. R.; Karavaev, A. S.
2018-04-01
A model of human cardiovascular system is proposed to describe the main heart rhythm, influence of autonomous regulation on frequency and strength of heart contractions and resistance of arterial vessels; process of formation of arterial pressure during systolic and diastolic phases; influence of respiration; synchronization between loops of autonomous regulation. The proposed model is used to simulate the dynamics of heart rate and arterial pressure during passive transition from supine to upright position. Results of mathematical modeling are compared to original experimental data.
Studer, Valeria; Rocchi, Camilla; Motta, Caterina; Lauretti, Benedetta; Perugini, Jacopo; Brambilla, Laura; Pareja-Gutierrez, Lorena; Camera, Giorgia; Barbieri, Francesca Romana; Marfia, Girolama A; Centonze, Diego; Rossi, Silvia
2017-01-01
Sympathovagal imbalance has been associated with poor prognosis in chronic diseases, but there is conflicting evidence in multiple sclerosis. The objective of this study was to investigate the autonomic nervous system dysfunction correlation with inflammation and progression in multiple sclerosis. Heart rate variability was analysed in 120 multiple sclerosis patients and 60 healthy controls during supine rest and head-up tilt test; the normalised units of low frequency and high frequency power were considered to assess sympathetic and vagal components, respectively. Correlation analyses with clinical and radiological markers of disease activity and progression were performed. Sympathetic dysfunction was closely related to the progression of disability in multiple sclerosis: progressive patients showed altered heart rate variability with respect to healthy controls and relapsing-remitting patients, with higher rest low frequency power and lacking the expected low frequency power increase during the head-up tilt test. In relapsing-remitting patients, disease activity, even subclinical, was associated with lower rest low frequency power, whereas stable relapsing-remitting patients did not differ from healthy controls. Less sympathetic reactivity and higher low frequency power at rest were associated with incomplete recovery from relapse. Autonomic balance appears to be intimately linked with both the inflammatory activity of multiple sclerosis, which is featured by an overall hypoactivity of the sympathetic nervous system, and its compensatory plastic processes, which appear inefficient in case of worsening and progressive multiple sclerosis.
Griefahn, Barbara; Künemund, Christa; Blaszkewicz, Meinolf; Lerchl, Alexander; Degen, Gisela H
2002-10-01
Electromagnetic spectra reduce melatonin production and delay the nadirs of rectal temperature and heart rate. Seven healthy men (16-22 yrs) completed 4 permuted sessions. The control session consisted of a 24-hours bedrest at < 30 lux, 18 degrees C, and < 50 dBA. In the experimental sessions, either light (1500 lux), magnetic field (16.7 Hz, 0.2 mT), or infrared radiation (65 degrees C) was applied from 5 pm to 1 am. Salivary melatonin level was determined hourly, rectal temperature and heart rate were continuously recorded. Melatonin synthesis was completely suppressed by light but resumed thereafter. The nadirs of rectal temperature and heart rate were delayed. The magnetic field had no effect. Infrared radiation elevated rectal temperature and heart rate. Only bright light affected the circadian rhythms of melatonin synthesis, rectal temperature, and heart rate, however, differently thus causing a dissociation, which might enhance the adverse effects of shiftwork in the long run.
Heart rate and blood pressure variabilities in salt-sensitive hypertension.
Piccirillo, G; Bucca, C; Durante, M; Santagada, E; Munizzi, M R; Cacciafesta, M; Marigliano, V
1996-12-01
In salt-sensitive hypertension, a high sodium intake causes plasma catecholamines to rise and pulmonary baroreceptor plasticity to fall. In salt-sensitive and salt-resistant hypertensive subjects during low and high sodium intakes, we studied autonomic nervous system activity by power spectral analysis of heart rate and arterial pressure variabilities and baroreceptor sensitivity. In all subjects, high sodium intake significantly enhanced the low-frequency power of heart rate and arterial pressures at rest and after sympathetic stress. It also increased heart rate and arterial pressure variabilities. During high sodium intake, salt-sensitive hypertensive subjects had significantly higher low-frequency powers of systolic arterial pressure (7.5 mm Hg2, P < .05) and of heart rate at rest (59.2 +/- 2.4 normalized units [NU], P < .001) than salt-resistant subjects (6.6 +/- 0.3 mm Hg2, 55.0 +/- 3.2 NU) and normotensive control subjects (5.1 +/- 0.5 mm Hg2, 41.6 +/- 2.9 NU). In salt-sensitive subjects, low sodium intake significantly reduced low-frequency normalized units (P < .001) and the ratio of low- to high-power frequency (P < .001). High-sodium intake significantly increased baroreflex sensitivity in control subjects (from 10.0 +/- 0.7 to 17.5 +/- 0.7 ms/mm Hg, P < .001) and salt-resistant subjects (from 6.9 +/- 0.7 to 13.9 +/- 0.9, P < .05) but not in salt-sensitive subjects (7.4 +/- 0.3 to 7.9 +/- 0.4). In conclusion, a high sodium intake markedly enhances cardiac sympathetic activity in salt-sensitive and salt-resistant hypertension. In contrast, although reduced sodium intake lowers arterial pressure and sympathetic activity, it does so only in salt-sensitive subjects. Hence, in salt-resistant subjects, neither arterial pressure nor sympathetic activity depends on salt intake. During a high sodium intake in normotensive subjects and salt-resistant hypertensive subjects, increased sympathetic activity is probably compensated by enhanced baroreflex sensitivity.
Bartur, Gadi; Vatine, Jean-Jacques; Raphaely-Beer, Noa; Peleg, Sara; Katz-Leurer, Michal
2014-09-01
The objective of this study is to assess the autonomic nerve heart rate regulation system at rest and its immediate response to paced breathing among patients with complex regional pain syndrome (CRPS) as compared with age-matched healthy controls. Quasiexperimental. Outpatient clinic. Ten patients with CRPS and 10 age- and sex-matched controls. Participants underwent Holter ECG (NorthEast Monitoring, Inc., Maynard, MA, USA) recording during rest and biofeedback-paced breathing session. Heart rate variability (HRV), time, and frequency measures were assessed. HRV and time domain values were significantly lower at rest among patients with CRPS as compared with controls. A significant association was noted between pain rank and HRV frequency measures at rest and during paced breathing; although both groups reduced breathing rate significantly during paced breathing, HRV time domain parameters increased only among the control group. The increased heart rate and decreased HRV at rest in patients with CRPS suggest a general autonomic imbalance. The inability of the patients to increase HRV time domain values during paced breathing may suggest that these patients have sustained stress response with minimal changeability in response to slow-paced breathing stimuli. Wiley Periodicals, Inc.
Wang, L; Wu, L; Ji, G; Zhang, X; Chen, T; Wang, L
1998-12-01
Effects of upright tilt on mechanism of autonomic nervous regulation of cardiovascular system and characteristics of heart rate variability (HRV) were observed in sixty healthy male pilots. Relation between time domain and frequency domain indexes of short-time HRV (5 min) were analysed before and after upright tilt. The results showed that there are significant difference in short time HRV parameters before and after upright tilt. Significant relationship was formed between time domain and frequency domain indexes of HRV. It suggests that time domain and frequency domain HRV analysis is capable of revealing certain informations embedded in a short series of R-R intervals and can help to evaluate the status of autonomic regulation of cardiovascular function in pilots.
Campbell, Hamish A; Leite, Cleo A C; Wang, Tobias; Skals, Marianne; Abe, Augusto S; Egginton, Stuart; Rantin, F Tadeu; Bishop, Charles M; Taylor, Edwin W
2006-07-01
Autonomic control of heart rate variability and the central location of vagal preganglionic neurones (VPN) were examined in the rattlesnake (Crotalus durissus terrificus), in order to determine whether respiratory sinus arrhythmia (RSA) occurred in a similar manner to that described for mammals. Resting ECG signals were recorded in undisturbed snakes using miniature datalogging devices, and the presence of oscillations in heart rate (fh) was assessed by power spectral analysis (PSA). This mathematical technique provides a graphical output that enables the estimation of cardiac autonomic control by measuring periodic changes in the heart beat interval. At fh above 19 min(-1) spectra were mainly characterised by low frequency components, reflecting mainly adrenergic tonus on the heart. By contrast, at fh below 19 min(-1) spectra typically contained high frequency components, demonstrated to be cholinergic in origin. Snakes with a fh >19 min(-1) may therefore have insufficient cholinergic tonus and/or too high an adrenergic tonus acting upon the heart for respiratory sinus arrhythmia (RSA) to develop. A parallel study monitored fh simultaneously with the intraperitoneal pressures associated with lung inflation. Snakes with a fh<19 min(-1) exhibited a high frequency (HF) peak in the power spectrum, which correlated with ventilation rate (fv). Adrenergic blockade by propranolol infusion increased the variability of the ventilation cycle, and the oscillatory component of the fh spectrum broadened accordingly. Infusion of atropine to effect cholinergic blockade abolished this HF component, confirming a role for vagal control of the heart in matching fh and fv in the rattlesnake. A neuroanatomical study of the brainstem revealed two locations for vagal preganglionic neurones (VPN). This is consistent with the suggestion that generation of ventilatory components in the heart rate variability (HRV) signal are dependent on spatially distinct loci for cardiac VPN. Therefore, this study has demonstrated the presence of RSA in the HRV signal and a dual location for VPN in the rattlesnake. We suggest there to be a causal relationship between these two observations.
Sustained attention and heart rate variability in children and adolescents with ADHD.
Griffiths, Kristi R; Quintana, Daniel S; Hermens, Daniel F; Spooner, Chris; Tsang, Tracey W; Clarke, Simon; Kohn, Michael R
2017-03-01
The autonomic nervous system (ANS) plays an important role in attention and self-regulation by modulating physiological arousal to meet environmental demands. Core symptoms of ADHD such as inattention and behavioral disinhibition may be related to dysregulation of the ANS, however previous findings have been equivocal. We examined autonomic activity and reactivity by assessing heart rate variability (HRV) in a large sample of un-medicated children and adolescents (6-19 years) with ADHD (n=229) compared to typically-developing controls (n=244) during rest and sustained attention. Four heart rate variability measures were extracted: Root mean square of successive differences between inter-beat-intervals (rMSSD), absolute high frequency (HFA) power, absolute low frequency (LFA) power and ratio of low frequency power to high frequency power (LF/HF). There were no group differences in HFA or rMSSD, even when assessing across child and adolescent groups separately, by gender or ADHD subtype. LF/HF however was higher in ADHD during both rest and sustained attention conditions, particularly in male children. Sustained attention was impaired in ADHD relative to controls, and a higher LF/HF ratio during sustained attention was associated with poorer performance in both groups. Lower rMSSD and HFA were associated with higher anxiety, oppositional behaviors and social problems, supporting prevailing theories that these measures index emotion regulation and adaptive social behavior. Different measures of heart rate variability provide important insights into the sustained attention and emotional and behavioral regulation impairments observed in ADHD and may aid in delineating ADHD pathophysiology. Copyright © 2017 Elsevier B.V. All rights reserved.
Toward Hypertension Prediction Based on PPG-Derived HRV Signals: a Feasibility Study.
Lan, Kun-Chan; Raknim, Paweeya; Kao, Wei-Fong; Huang, Jyh-How
2018-04-21
Heart rate variability (HRV) is often used to assess the risk of cardiovascular disease, and data on this can be obtained via electrocardiography (ECG). However, collecting heart rate data via photoplethysmography (PPG) is now a lot easier. We investigate the feasibility of using the PPG-based heart rate to estimate HRV and predict diseases. We obtain three months of PPG-based heart rate data from subjects with and without hypertension, and calculate the HRV based on various forms of time and frequency domain analysis. We then apply a data mining technique to this estimated HRV data, to see if it is possible to correctly identify patients with hypertension. We use six HRV parameters to predict hypertension, and find SDNN has the best predictive power. We show that early disease prediction is possible through collecting one's PPG-based heart rate information.
Vasků, A; Soucek, M; Goldbergová, M; Vácha, J
2003-01-01
The aim of the study was to assess the association between promoter polymorphism [A(-596)G] in interleukin-6 gene and office systolic and diastolic blood pressures, and the heart rate (HR) in apparently healthy Czech subjects. Furthermore, we evaluated the possible influence of gender, BMI and smoking on these supposed associations. An age-matched (40-50 years) and gender-matched (F/M=81/89) sample of apparently healthy Czech subjects (n=170, F/M=81/89) without hypertension, other cardiovascular diseases or diabetes was examined. The A(-596)G Il-6 gene polymorphism was detected by the PCR method. No differences in genotype distribution and/or allelic frequency was found between groups with lower systolic blood pressure (Ł 122 mm Hg) and higher systolic blood pressure (> 122 mm Hg). Similarly, no differences in the IL-6 polymorphism were found between lower (Ł 86 mm Hg) and higher (> 86 mm Hg) diastolic blood pressure groups. However, we proved a significant increase of genotypes AG+GG as well as the allele (-596)G in higher (>78 beats/min) heart rate group. The genotypes AG+GG represent significantly higher relative risk for higher HR frequency, especially in women. Among lean persons with a low heart rate frequency, fewer AG+GG genotypes were determined than among any other subjects. The genotypes AG+GG are more frequent in non-smoking persons with higher HR compared to non-smoking subjects with lower HR, especially in women. Gender, BMI and smoking substantially modify the distribution of A(-596)G Il-6 gene polymorphism in apparently healthy persons with lower or higher heart rate.
Okada, Masahiro; Kakehashi, Masayuki
2014-01-01
The influences of body weight and air temperature on the autonomic response to food intake have not been clarified. We measured heart rate variability before and after lunch, as well as the effects of outdoor temperature and increased body mass index (BMI), in healthy young Japanese women. We studied 55 healthy young female university students. Heart rate variability was measured before lunch, immediately after lunch, 30 min after lunch, and 1 h after lunch to determine any correlations between heart rate variability, outdoor temperature, and BMI. In addition, multiple regression analysis was performed to elucidate the relationship between heart rate variability and outdoor temperature before and after lunch. A simple slope test was conducted to show the relationship between the low-to-high frequency ratio (1 h after lunch) and outdoor temperature. Subjects were divided into a low BMI group (range: 16.6-20.3) and a high BMI group (range: 20.4-32.9). The very low frequency component of heart rate variability, an index of thermoregulatory vasomotor control exerted by the sympathetic nervous system, was significantly diminished after lunch in the high BMI group (P < 0.01). A significant decrease in the low-to-high frequency (LF/HF) ratio, which represents the balance between the parasympathetic and sympathetic nervous systems, was evident in the low BMI group after lunch, indicating parasympathetic system dominance (P = 0.001). In addition, a significant association was found between the LF/HF ratio and outdoor temperature after lunch with a lower BMI (P = 0.002), but this association disappeared with higher BMIs. Autonomic responses to eating showed clear differences according to BMI, indicating that the sensitivity of the autonomic nervous system may change with increases in BMI.
Schaun, Gustavo Z; Del Vecchio, Fabrício B
2018-01-01
Schaun, GZ and Del Vecchio, FB. High-intensity interval exercises' acute impact on heart rate variability: comparison between whole-body and cycle ergometer protocols. J Strength Cond Res 32(1): 223-229, 2018-Study aimed to compare the effects of 2 high-intensity interval training (HIIT) protocols on heart rate variability. Twelve young adult males (23.3 ± 3.9 years, 177.8 ± 7.4 cm, 76.9 ± 12.9 kg) volunteered to participate. In a randomized cross-over design, subjects performed 2 HIIT protocols, 1 on a cycle ergometer (Tabata protocol [TBT]; eight 20-second bouts at 170% Pmax interspersed by 10-second rest) and another with whole-body calisthenic exercises (McRae protocol; eight 20-second all-out intervals interspersed by 10-second rest). Heart rate variability outcomes in the time, frequency, and nonlinear domains were assessed on 3 moments: (a) presession; (b) immediately postsession; and (c) 24 hours postsession. Results revealed that RRmean, Ln rMSSD, Ln high frequency (HF), and Ln low frequency (LF) were significantly reduced immediately postsession (p ≤ 0.001) and returned to baseline 24 h after both protocols. In addition, LF/HF ratio was reduced 24 h postsession (p ≤ 0.01) and SD2 was significantly lower immediately postsession only in TBT. Our main finding was that responses from heart rate autonomic control were similar in both protocols, despite different modes of exercise performed. Specifically, exercises resulted in a high parasympathetic inhibition immediately after session with subsequent recovery within 1 day. These results suggest that subjects were already recovered the day after and can help coaches to better program training sessions with such protocols.
Heart rate detection from an electronic weighing scale.
González-Landaeta, R; Casas, O; Pallàs-Areny, R
2008-08-01
We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V(-1) N(-1) to 1670 nV V(-1) N(-1). The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland-Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was +/-21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate.
National culture moderates the influence of mental effort on subjective and cardiovascular measures.
Widyanti, Ari; de Waard, Dick; Johnson, Addie; Mulder, Ben
2013-01-01
Subjective measures of mental effort have been shown to be relatively insensitive in Indonesian participants. An open question is whether this insensitivity reflects how mental effort is experienced or how it is reported. We compared the performance, subjective workload ratings, heart rate and heart-rate variability (HRV) of 31 Dutch and 30 Indonesian participants under single- and dual-task conditions. Indonesians performed faster but less accurately and used a narrower range of subjective workload ratings than did the Dutch. Dutch participants showed a decrease in HRV both in the mid-frequency (MF) and high-frequency bands and an increase in heart rate during task performance compared with the resting period. Indonesians showed this pattern in the MF band only. The decrease of HRV in the MF band in both groups suggests that the relative insensitivity of subjective mental effort scales among Indonesians has to do with how workload is reported rather than with how it is experienced. The sensitivity of the subjective measures of mental workload has been shown to depend on culture. Here, we show that heart-rate variability reacts similarly to workload in Eastern as in Western participants. This suggests that culture influences more how invested mental effort is reported than how it is experienced psychophysiologically.
Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin
2017-09-26
Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.
Sleep-wake differences in heart rate variability during a 105-day simulated mission to Mars.
Vigo, Daniel E; Ogrinz, Barbara; Wan, Li; Bersenev, Evgeny; Tuerlinckx, Francis; Van Den Bergh, Omer; Aubert, André E
2012-02-01
In prolonged spaceflights the effect of long-term confinement on the autonomic regulation of the heart is difficult to separate from the effect of prolonged exposure to microgravity or other space-related stressors. Our objective was to investigate whether the sleep-wake variations in the autonomic control of the heart are specifically altered by long-term confinement during the 105-d pilot study of the Earth-based Mars500 project. Before (pre), during (T1: 30, T2: 70, andT3: 100 d), and after (post) confinement, 24-h EKG records were obtained from the six crewmembers that participated in the mission. Sleep and wake periods were determined by fitting a square wave to the data. Autonomic activity was evaluated through time and frequency domain indexes of heart rate variability (HRV) analysis during wake and sleep periods. During confinement, wake HRV showed decreased mean heart rate and increased amplitude at all frequency levels, particularly in the very low (pre: 13.3 +/- 0.2; T1: 13.9 +/- 0.3; T2: 13.9 +/- 0.2; T3: 13.9 +/- 0.2; post: 13.2 +/- 0.2) and high (pre: 7.6 +/- 0.4; T1: 8.3 +/- 0.5; T2: 8.2 +/- 0.4; T3: 8.1 +/- 0.4; post: 7.6 +/- 0.3) frequency components (values expressed as mean +/- SE of wavelet power coefficients). Sleep HRV remained constant, while sleep-wake high frequency HRV differences diminished. The observed autonomic changes during confinement reflect an increase in parasympathetic activity during wake periods. Several factors could account for this observation, including reduced daylight exposure related to the confinement situation.
Joukar, Siyavash; Dehesh, Mohammad-Moein
2015-12-01
Dry stigmas of the Crocus sativus L. (Saffron) are well known in world as a popular flavouring and therapeutic agent. The anxiolytic, antidepressant, anticonvulsant and antiarrhythmic effects of saffron suggest that it may affect the autonomic control of the heart. This study assessed its safety on cardiac sympathovagal balance and heart rate variability in rat. Experimental groups were control, Saf50, Saf100, Saf200 (received saffron at dosages of 50 and 100 and 200 mg/kg/d, orally, respectively) and Amio (received 30 mg/mL/kg/d of amiodarone, orally, for 7 days) groups. On day 8, the frequency domain and time domain indices of animals' electrocardiograms were calculated. The heart rate decreased and RR interval increased in Saf200 and Amio groups (P<.05 vs other groups). Square root of the mean squared differences of successive RR intervals enhanced in all treated groups, however, was only significant in Amio group (P<.05). The SD1/SD2 ratio was higher in Saf200 and Amio groups. Both low-frequency (LF) and high-frequency (HF) parameters were higher, and the LF/HF ratio was non-significantly lower in treated groups. The findings suggest that saffron not only has no harmful effect on activity of cardiac autonomic nervous system, but it may improve the stability of heart sympathovagal balance in normal rat. © 2016 John Wiley & Sons Ltd.
A protocol to study ex vivo mouse working heart at human-like heart rate.
Feng, Han-Zhong; Jin, Jian-Ping
2018-01-01
Genetically modified mice are widely used as experimental models to study human heart function and diseases. However, the fast rate of normal mouse heart at 400-600bpm limits its capacity of assessing kinetic parameters that are important for the physiology and pathophysiology of human heart that beats at a much slower rate (75-180bpm). To extend the value of mouse models, we established a protocol to study ex vivo mouse working hearts at a human-like heart rate. In the presence of 300μM lidocaine to lower pacemaker and conductive activities and prevent arrhythmia, a stable rate of 120-130bpm at 37°C is achieved for ex vivo mouse working hearts. The negative effects of decreased heart rate on force-frequency dependence and lidocaine as a myocardial depressant on intracellular calcium can be compensated by using a higher but still physiological level of calcium (2.75mM) in the perfusion media. Multiple parameters were studied to compare the function at the human-like heart rate with that of ex vivo mouse working hearts at the standard rate of 480bpm. The results showed that the conditions for slower heart rate in the presence of 300μM lidocaine did not have depressing effect on left ventricular pressure development, systolic and diastolic velocities and stroke volume with maintained positive inotropic and lusitropic responses to β-adrenergic stimulation. Compared with that at 480bpm, the human-like heart rate increased ventricular filling and end diastolic volume with enhanced Frank-Starling responses. Coronary perfusion was increased from longer relaxation time and interval between beats whereas cardiac efficiency was significantly improved. Although the intrinsic differences between mouse and human heart remain, this methodology for ex vivo mouse hearts to work at human-like heart rate extends the value of using genetically modified mouse models to study cardiac function and human heart diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.
High frequency ultrasound: a new frontier for ultrasound.
Shung, K; Cannata, Jonathan; Qifa Zhou, Member; Lee, Jungwoo
2009-01-01
High frequency ultrasonic imaging is considered by many to be the next frontier in ultrasonic imaging because higher frequencies yield much improved spatial resolution by sacrificing the depth of penetration. It has many clinical applications including visualizing blood vessel wall, anterior segments of the eye and skin. Another application is small animal imaging. Ultrasound is especially attractive in imaging the heart of a small animal like mouse which has a size in the mm range and a heart beat rate faster than 600 BPM. A majority of current commercial high frequency scanners often termed "ultrasonic backscatter microscope or UBM" acquire images by scanning single element transducers at frequencies between 50 to 80 MHz with a frame rate lower than 40 frames/s, making them less suitable for this application. High frequency linear arrays and linear array based ultrasonic imaging systems at frequencies higher than 30 MHz are being developed. The engineering of such arrays and development of high frequency imaging systems has been proven to be highly challenging. High frequency ultrasound may find other significant biomedical applications. The development of acoustic tweezers for manipulating microparticles is such an example.
Isoflurane increases cardiorespiratory coordination in rats
NASA Astrophysics Data System (ADS)
Kabir, Muammar M.; Beig, Mirza I.; Nalivaiko, Eugene; Abbott, Derek; Baumert, Mathias
2008-12-01
Anesthetics such as isoflurane adversely affect heart rate. In this study we analysed the interaction between heart rhythm and respiration at different concentrations of isoflurane and ventilation rates. In two rats, the electrocardiogram (ECG) and respiratory signals were recorded under the influence of isoflurane. For the assessment of cardiorespiratory coordination, we analysed the phase locking between heart rate, computed from the R-R intervals of body surface ECG, and respiratory rate, computed from impedance changes, using Hilbert transform. The changes in heart rate, percentage of synchronization and duration of synchronized epochs at different isoflurane concentrations and ventilation rates were assessed using linear regression model. From this study it appears that the amount of phase locking between cardiac and respiratory rates increases with the increase in concentration of isoflurane. Heart rate and duration of synchronized epochs increased significantly with the increase in the level of isoflurane concentration while respiratory rate was not significantly affected. Cardiorespiratory coordination also showed a considerable increase at the ventilation rates of 50- 55 cpm in both the rats, suggesting that the phase-locking between the cardiac and respiratory oscillators can be increased by breathing at a particular respiratory frequency.
Discovery of novel heart rate-associated loci using the Exome Chip
van den Berg, Marten E.; Warren, Helen R.; Cabrera, Claudia P.; Verweij, Niek; Mifsud, Borbala; Haessler, Jeffrey; Bihlmeyer, Nathan A.; Fu, Yi-Ping; Weiss, Stefan; Lin, Henry J.; Grarup, Niels; Li-Gao, Ruifang; Pistis, Giorgio; Shah, Nabi; Brody, Jennifer A.; Müller-Nurasyid, Martina; Lin, Honghuang; Mei, Hao; Smith, Albert V.; Lyytikäinen, Leo-Pekka; Hall, Leanne M.; van Setten, Jessica; Trompet, Stella; Prins, Bram P.; Isaacs, Aaron; Radmanesh, Farid; Marten, Jonathan; Entwistle, Aiman; Kors, Jan A.; Silva, Claudia T.; Alonso, Alvaro; Bis, Joshua C.; de Boer, Rudolf; de Haan, Hugoline G.; de Mutsert, Renée; Dedoussis, George; Dominiczak, Anna F.; Doney, Alex S. F.; Ellinor, Patrick T.; Eppinga, Ruben N.; Felix, Stephan B.; Guo, Xiuqing; Hagemeijer, Yanick; Hansen, Torben; Harris, Tamara B.; Heckbert, Susan R.; Huang, Paul L.; Hwang, Shih-Jen; Kähönen, Mika; Kanters, Jørgen K.; Kolcic, Ivana; Launer, Lenore J.; Li, Man; Yao, Jie; Linneberg, Allan; Liu, Simin; Macfarlane, Peter W.; Mangino, Massimo; Morris, Andrew D.; Mulas, Antonella; Murray, Alison D.; Nelson, Christopher P.; Orrú, Marco; Padmanabhan, Sandosh; Peters, Annette; Porteous, David J.; Poulter, Neil; Psaty, Bruce M.; Qi, Lihong; Raitakari, Olli T.; Rivadeneira, Fernando; Roselli, Carolina; Rudan, Igor; Sattar, Naveed; Sever, Peter; Sinner, Moritz F.; Soliman, Elsayed Z.; Spector, Timothy D.; Stanton, Alice V.; Stirrups, Kathleen E.; Taylor, Kent D.; Tobin, Martin D.; Uitterlinden, André; Vaartjes, Ilonca; Hoes, Arno W.; van der Meer, Peter; Völker, Uwe; Waldenberger, Melanie; Xie, Zhijun; Zoledziewska, Magdalena; Tinker, Andrew; Polasek, Ozren; Rosand, Jonathan; Jamshidi, Yalda; van Duijn, Cornelia M.; Zeggini, Eleftheria; Jukema, J. Wouter; Asselbergs, Folkert W.; Samani, Nilesh J.; Lehtimäki, Terho; Gudnason, Vilmundur; Wilson, James; Lubitz, Steven A.; Kääb, Stefan; Sotoodehnia, Nona; Caulfield, Mark J.; Palmer, Colin N. A.; Sanna, Serena; Mook-Kanamori, Dennis O.; Deloukas, Panos; Pedersen, Oluf; Rotter, Jerome I.; Dörr, Marcus; O'Donnell, Chris J.; Hayward, Caroline; Arking, Dan E.; Kooperberg, Charles; van der Harst, Pim; Eijgelsheim, Mark; Stricker, Bruno H.; Munroe, Patricia B.
2017-01-01
Abstract Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to discover new genetic loci associated with heart rate from Exome Chip meta-analyses. Heart rate was measured from either elecrtrocardiograms or pulse recordings. We meta-analysed heart rate association results from 104 452 European-ancestry individuals from 30 cohorts, genotyped using the Exome Chip. Twenty-four variants were selected for follow-up in an independent dataset (UK Biobank, N = 134 251). Conditional and gene-based testing was undertaken, and variants were investigated with bioinformatics methods. We discovered five novel heart rate loci, and one new independent low-frequency non-synonymous variant in an established heart rate locus (KIAA1755). Lead variants in four of the novel loci are non-synonymous variants in the genes C10orf71, DALDR3, TESK2 and SEC31B. The variant at SEC31B is significantly associated with SEC31B expression in heart and tibial nerve tissue. Further candidate genes were detected from long-range regulatory chromatin interactions in heart tissue (SCD, SLF2 and MAPK8). We observed significant enrichment in DNase I hypersensitive sites in fetal heart and lung. Moreover, enrichment was seen for the first time in human neuronal progenitor cells (derived from embryonic stem cells) and fetal muscle samples by including our novel variants. Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies. PMID:28379579
Discovery of novel heart rate-associated loci using the Exome Chip.
van den Berg, Marten E; Warren, Helen R; Cabrera, Claudia P; Verweij, Niek; Mifsud, Borbala; Haessler, Jeffrey; Bihlmeyer, Nathan A; Fu, Yi-Ping; Weiss, Stefan; Lin, Henry J; Grarup, Niels; Li-Gao, Ruifang; Pistis, Giorgio; Shah, Nabi; Brody, Jennifer A; Müller-Nurasyid, Martina; Lin, Honghuang; Mei, Hao; Smith, Albert V; Lyytikäinen, Leo-Pekka; Hall, Leanne M; van Setten, Jessica; Trompet, Stella; Prins, Bram P; Isaacs, Aaron; Radmanesh, Farid; Marten, Jonathan; Entwistle, Aiman; Kors, Jan A; Silva, Claudia T; Alonso, Alvaro; Bis, Joshua C; de Boer, Rudolf; de Haan, Hugoline G; de Mutsert, Renée; Dedoussis, George; Dominiczak, Anna F; Doney, Alex S F; Ellinor, Patrick T; Eppinga, Ruben N; Felix, Stephan B; Guo, Xiuqing; Hagemeijer, Yanick; Hansen, Torben; Harris, Tamara B; Heckbert, Susan R; Huang, Paul L; Hwang, Shih-Jen; Kähönen, Mika; Kanters, Jørgen K; Kolcic, Ivana; Launer, Lenore J; Li, Man; Yao, Jie; Linneberg, Allan; Liu, Simin; Macfarlane, Peter W; Mangino, Massimo; Morris, Andrew D; Mulas, Antonella; Murray, Alison D; Nelson, Christopher P; Orrú, Marco; Padmanabhan, Sandosh; Peters, Annette; Porteous, David J; Poulter, Neil; Psaty, Bruce M; Qi, Lihong; Raitakari, Olli T; Rivadeneira, Fernando; Roselli, Carolina; Rudan, Igor; Sattar, Naveed; Sever, Peter; Sinner, Moritz F; Soliman, Elsayed Z; Spector, Timothy D; Stanton, Alice V; Stirrups, Kathleen E; Taylor, Kent D; Tobin, Martin D; Uitterlinden, André; Vaartjes, Ilonca; Hoes, Arno W; van der Meer, Peter; Völker, Uwe; Waldenberger, Melanie; Xie, Zhijun; Zoledziewska, Magdalena; Tinker, Andrew; Polasek, Ozren; Rosand, Jonathan; Jamshidi, Yalda; van Duijn, Cornelia M; Zeggini, Eleftheria; Jukema, J Wouter; Asselbergs, Folkert W; Samani, Nilesh J; Lehtimäki, Terho; Gudnason, Vilmundur; Wilson, James; Lubitz, Steven A; Kääb, Stefan; Sotoodehnia, Nona; Caulfield, Mark J; Palmer, Colin N A; Sanna, Serena; Mook-Kanamori, Dennis O; Deloukas, Panos; Pedersen, Oluf; Rotter, Jerome I; Dörr, Marcus; O'Donnell, Chris J; Hayward, Caroline; Arking, Dan E; Kooperberg, Charles; van der Harst, Pim; Eijgelsheim, Mark; Stricker, Bruno H; Munroe, Patricia B
2017-06-15
Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to discover new genetic loci associated with heart rate from Exome Chip meta-analyses.Heart rate was measured from either elecrtrocardiograms or pulse recordings. We meta-analysed heart rate association results from 104 452 European-ancestry individuals from 30 cohorts, genotyped using the Exome Chip. Twenty-four variants were selected for follow-up in an independent dataset (UK Biobank, N = 134 251). Conditional and gene-based testing was undertaken, and variants were investigated with bioinformatics methods.We discovered five novel heart rate loci, and one new independent low-frequency non-synonymous variant in an established heart rate locus (KIAA1755). Lead variants in four of the novel loci are non-synonymous variants in the genes C10orf71, DALDR3, TESK2 and SEC31B. The variant at SEC31B is significantly associated with SEC31B expression in heart and tibial nerve tissue. Further candidate genes were detected from long-range regulatory chromatin interactions in heart tissue (SCD, SLF2 and MAPK8). We observed significant enrichment in DNase I hypersensitive sites in fetal heart and lung. Moreover, enrichment was seen for the first time in human neuronal progenitor cells (derived from embryonic stem cells) and fetal muscle samples by including our novel variants.Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies. © The Author 2017. Published by Oxford University Press.
HRV Analysis to Identify Stages of Home-based Telerehabilitation Exercise.
Jeong, In Cheol; Finkelstein, Joseph
2014-01-01
Spectral analysis of heart rate variability (HRV) has been widely used to investigate activity of autonomous nervous system. Previous studies demonstrated potential of analysis of short-term sequences of heart rate data in a time domain for continuous monitoring of levels of physiological stress however the value of HRV parameters in frequency domain for monitoring cycling exercise has not been established. The goal of this study was to assess whether HRV parameters in frequency domain differ depending on a stage of cycling exercise. We compared major HRV parameters in high, low and very low frequency ranges during rest, height of exercise, and recovery during cycling exercise. Our results indicated responsiveness of frequency-domain indices to different phases of cycling exercise program and their potential in monitoring autonomic balance and stress levels as a part of a tailored home-based telerehabilitation program.
Jones, Salene M W; Guthrie, Katherine A; LaCroix, Andrea Z; Sternfeld, Barbara; Landis, Carol A; Reed, Susan D; Dunn, Andrea; Caan, Bette; Cohen, Lee S; Hunt, Julie; Newton, Katherine M
2016-02-01
Research has suggested that the autonomic nervous system (ANS) is involved in the experience of vasomotor symptoms (VMS) during menopause. We examined the relationship of VMS intensity and heart rate variability (HRV), a measure of ANS function. Women (n = 282) were recruited from three American states for a clinical trial of yoga, exercise, and omega-3 fatty acid supplements for VMS. To be eligible, women had to report at least 14 VMS per week, with some being moderate to severe. Sitting electrocardiograms were recorded for 15 min using Holter monitors at both baseline and 12-week follow-up. Time and frequency domain HRV measures were calculated. Women completed daily diary measures of VMS frequency and intensity for 2 weeks at baseline and for 1 week at the follow-up assessment 12 weeks later. Multivariable linear regression was used to assess the relationship between VMS and baseline HRV measures and to compare change in HRV with change in VMS over the 12 weeks. Baseline HRV was not associated with either VMS frequency or intensity at baseline. Change in HRV was not associated with change in VMS frequency or intensity across the follow-up. Heart rate variability (HRV) was not associated with basal VMS frequency or intensity in perimenopausal and postmenopausal women experiencing high levels of VMS. Autonomic function may be associated with the onset or presence of VMS, but not with the number or intensity of these symptoms.
Heart Rate Variability: Effect of Exercise Intensity on Postexercise Response
ERIC Educational Resources Information Center
James, David V. B.; Munson, Steven C.; Maldonado-Martin, Sara; De Ste Croix, Mark B. A.
2012-01-01
The purpose of the present study was to investigate the influence of two exercise intensities (moderate and severe) on heart rate variability (HRV) response in 16 runners 1 hr prior to (-1 hr) and at +1 hr, +24 hr, +48 hr, and +72 hr following each exercise session. Time domain indexes and a high frequency component showed a significant decrease…
Nunn, Nicolas; Feetham, Claire H; Martin, Jennifer; Barrett-Jolley, Richard; Plagge, Antonius
2013-01-01
New Findings What is the central question of this study? Previously, we showed that Gnasxl knock-out mice are lean and hypermetabolic, with increased sympathetic stimulation of adipose tissue. Do these mice also display elevated sympathetic cardiovascular tone? Is the brain glucagon-like peptide-1 system involved? What is the main finding and its importance? Gnasxl knock-outs have increased blood pressure, heart rate and body temperature. Heart rate variability analysis suggests an elevated sympathetic tone. The sympatholytic reserpine had stronger effects on blood pressure, heart rate and heart rate variability in knock-out compared with wild-type mice. Stimulation of the glucagon-like peptide-1 system inhibited parasympathetic tone to a similar extent in both genotypes, with a stronger associated increase in heart rate in knock-outs. Deficiency of Gnasxl increases sympathetic cardiovascular tone. Imbalances of energy homeostasis are often associated with cardiovascular complications. Previous work has shown that Gnasxl-deficient mice have a lean and hypermetabolic phenotype, with increased sympathetic stimulation of adipose tissue. The Gnasxl transcript from the imprinted Gnas locus encodes the trimeric G-protein subunit XLαs, which is expressed in brain regions that regulate energy homeostasis and sympathetic nervous system (SNS) activity. To determine whether Gnasxl knock-out (KO) mice display additional SNS-related phenotypes, we have now investigated the cardiovascular system. The Gnasxl KO mice were ∼20 mmHg hypertensive in comparison to wild-type (WT) littermates (P≤ 0.05) and hypersensitive to the sympatholytic drug reserpine. Using telemetry, we detected an increased waking heart rate in conscious KOs (630 ± 10 versus 584 ± 12 beats min−1, KO versus WT, P≤ 0.05). Body temperature was also elevated (38.1 ± 0.3 versus 36.9 ± 0.4°C, KO versus WT, P≤ 0.05). To investigate autonomic nervous system influences, we used heart rate variability analyses. We empirically defined frequency power bands using atropine and reserpine and verified high-frequency (HF) power and low-frequency (LF) LF/HF power ratio to be indicators of parasympathetic and sympathetic activity, respectively. The LF/HF power ratio was greater in KOs and more sensitive to reserpine than in WTs, consistent with elevated SNS activity. In contrast, atropine and exendin-4, a centrally acting agonist of the glucagon-like peptide-1 receptor, which influences cardiovascular physiology and metabolism, reduced HF power equally in both genotypes. This was associated with a greater increase in heart rate in KOs. Mild stress had a blunted effect on the LF/HF ratio in KOs consistent with elevated basal sympathetic activity. We conclude that XLαs is required for the inhibition of sympathetic outflow towards cardiovascular and metabolically relevant tissues. PMID:23748904
Association of autonomic nervous system and EEG scalp potential during playing 2D Grand Turismo 5.
Subhani, Ahmad Rauf; Likun, Xia; Saeed Malik, Aamir
2012-01-01
Cerebral activation and autonomic nervous system have importance in studies such as mental stress. The aim of this study is to analyze variations in EEG scalp potential which may influence autonomic activation of heart while playing video games. Ten healthy participants were recruited in this study. Electroencephalogram (EEG) and electrocardiogram (ECG) signals were measured simultaneously during playing video game and rest conditions. Sympathetic and parasympathetic innervations of heart were evaluated from heart rate variability (HRV), derived from the ECG. Scalp potential was measured by the EEG. The results showed a significant upsurge in the value theta Fz/alpha Pz (p<0.001) while playing game. The results also showed tachycardia while playing video game as compared to rest condition (p<0.005). Normalized low frequency power and ratio of low frequency/high frequency power were significantly increased while playing video game and normalized high frequency power sank during video games. Results showed synchronized activity of cerebellum and sympathetic and parasympathetic innervation of heart.
Heart-rate variability depression in porcine peritonitis-induced sepsis without organ failure.
Jarkovska, Dagmar; Valesova, Lenka; Chvojka, Jiri; Benes, Jan; Danihel, Vojtech; Sviglerova, Jitka; Nalos, Lukas; Matejovic, Martin; Stengl, Milan
2017-05-01
Depression of heart-rate variability (HRV) in conditions of systemic inflammation has been shown in both patients and experimental animal models and HRV has been suggested as an early indicator of sepsis. The sensitivity of HRV-derived parameters to the severity of sepsis, however, remains unclear. In this study we modified the clinically relevant porcine model of peritonitis-induced sepsis in order to avoid the development of organ failure and to test the sensitivity of HRV to such non-severe conditions. In 11 anesthetized, mechanically ventilated and instrumented domestic pigs of both sexes, sepsis was induced by fecal peritonitis. The dose of feces was adjusted and antibiotic therapy was administered to avoid multiorgan failure. Experimental subjects were screened for 40 h from the induction of sepsis. In all septic animals, sepsis with hyperdynamic circulation and increased plasma levels of inflammatory mediators developed within 12 h from the induction of peritonitis. The sepsis did not progress to multiorgan failure and there was no spontaneous death during the experiment despite a modest requirement for vasopressor therapy in most animals (9/11). A pronounced reduction of HRV and elevation of heart rate developed quickly (within 5 h, time constant of 1.97 ± 0.80 h for HRV parameter TINN) upon the induction of sepsis and were maintained throughout the experiment. The frequency domain analysis revealed a decrease in the high-frequency component. The reduction of HRV parameters and elevation of heart rate preceded sepsis-associated hemodynamic changes by several hours (time constant of 11.28 ± 2.07 h for systemic vascular resistance decline). A pronounced and fast reduction of HRV occurred in the setting of a moderate experimental porcine sepsis without organ failure. Inhibition of parasympathetic cardiac signaling probably represents the main mechanism of HRV reduction in sepsis. The sensitivity of HRV to systemic inflammation may allow early detection of a moderate sepsis without organ failure. Impact statement A pronounced and fast reduction of heart-rate variability occurred in the setting of a moderate experimental porcine sepsis without organ failure. Dominant reduction of heart-rate variability was found in the high-frequency band indicating inhibition of parasympathetic cardiac signaling as the main mechanism of heart-rate variability reduction. The sensitivity of heart-rate variability to systemic inflammation may contribute to an early detection of moderate sepsis without organ failure.
Heart Rate and Electrocardiography Monitoring in Mice
Ho, David; Zhao, Xin; Gao, Shumin; Hong, Chull; Vatner, Dorothy E.; Vatner, Stephen F.
2011-01-01
The majority of current cardiovascular research involves studies in genetically engineered mouse models. The measurement of heart rate is central to understanding cardiovascular control under normal conditions, with altered autonomic tone, superimposed stress or disease states, both in wild type mice as well as those with altered genes. Electrocardiography (ECG) is the “gold standard” using either hard wire or telemetry transmission. In addition, heart rate is measured or monitored from the frequency of the arterial pressure pulse or cardiac contraction, or by pulse oximetry. For each of these techniques, discussions of materials and methods, as well as advantages and limitations are covered. However, only the direct ECG monitoring will determine not only the precise heart rates but also whether the cardiac rhythm is normal or not. PMID:21743842
Shaffer, Fred
2015-01-01
Heart rate variability, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operates on different time scales to adapt to environmental and psychological challenges. This article briefly reviews neural regulation of the heart and offers some new perspectives on mechanisms underlying the very low frequency rhythm of heart rate variability. Interpretation of heart rate variability rhythms in the context of health risk and physiological and psychological self-regulatory capacity assessment is discussed. The cardiovascular regulatory centers in the spinal cord and medulla integrate inputs from higher brain centers with afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. We also discuss the intrinsic cardiac nervous system and the heart-brain connection pathways, through which afferent information can influence activity in the subcortical, frontocortical, and motor cortex areas. In addition, the use of real-time HRV feedback to increase self-regulatory capacity is reviewed. We conclude that the heart's rhythms are characterized by both complexity and stability over longer time scales that reflect both physiological and psychological functional status of these internal self-regulatory systems. PMID:25694852
McCraty, Rollin; Shaffer, Fred
2015-01-01
Heart rate variability, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operates on different time scales to adapt to environmental and psychological challenges. This article briefly reviews neural regulation of the heart and offers some new perspectives on mechanisms underlying the very low frequency rhythm of heart rate variability. Interpretation of heart rate variability rhythms in the context of health risk and physiological and psychological self-regulatory capacity assessment is discussed. The cardiovascular regulatory centers in the spinal cord and medulla integrate inputs from higher brain centers with afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. We also discuss the intrinsic cardiac nervous system and the heart-brain connection pathways, through which afferent information can influence activity in the subcortical, frontocortical, and motor cortex areas. In addition, the use of real-time HRV feedback to increase self-regulatory capacity is reviewed. We conclude that the heart's rhythms are characterized by both complexity and stability over longer time scales that reflect both physiological and psychological functional status of these internal self-regulatory systems.
Playing a violent television game affects heart rate variability.
Ivarsson, Malena; Anderson, Martin; Akerstedt, Torbjörn; Lindblad, Frank
2009-01-01
To investigate how playing a violent/nonviolent television game during the evening affects sympathetic and parasympathetic reactions during and after playing as well as sleep quality during the night after playing. In total, 19 boys, 12-15 years of age, played television games on two occasions in their homes and participated once without gaming. Heart rate, heart rate variability (HRV) and physical activity were measured during gaming/participating and the night to follow using a portable combined heart rate and movement sensor. A sleep diary and questionnaires about gaming experiences and session-specific experiences were filled in. Criteria for Selection of Games: Violent game involves/rewards direct physical violence (no handguns) against another person, and nonviolent game involves/rewards no violence; same game design ('third-person game'); conducted in the same manner; no differences concerning motor activity; similar sound and light effects; no sexual content, violence against women or racial overtones. During violent (vs. nonviolent) gaming, there was significantly higher activity of the very low frequency component of the HRV and total power. During the night after playing, very low frequency, low frequency and high frequency components were significantly higher during the violent (vs. nonviolent) condition, just as total power. There were no significant differences between the three conditions (violent/nonviolent/no gaming) with respect to an index reflecting subjectively perceived sleep difficulties. Nor was there any difference between violent and nonviolent condition for any single sleep item. Violent gaming induces different autonomic responses in boys compared to nonviolent gaming--during playing and during the following night--suggesting different emotional responses. Subjectively perceived sleep quality is not influenced after a single gaming experience. Future studies should address the development of the autonomic balance after gaming over longer time than a night, physiological adaptation to frequent gaming and potential gender differences.
The Influence of Word Frequency on Word Retrieval: Measuring Covert Behaviors
ERIC Educational Resources Information Center
Chih, Yu-Chun; Stierwalt, Julie A. G.; LaPointe, Leonard L.; Chih, Yu-Pin
2017-01-01
Physiological activities (heart rate and respiratory rate) during a word retrieval task were measured in normal participants. Word frequency demonstrated a significant effect on naming accuracy and latencies but not on physiological activities. These data will serve as a basis for comparison for individuals with a compromised language system.
Electroacupuncture most effectively elicits depressor and bradycardic responses at 1 Hz in humans.
Nakahara, Hidehiro; Kawada, Toru; Ueda, Shin-ya; Kawai, Eriko; Yamamoto, Hiromi; Sugimachi, Masaru; Miyamoto, Tadayoshi
2016-02-01
Acupuncture stimulation is known to act on the autonomic nervous system and elicits depressor and bradycardic effects. However, previous studies on humans did not conduct quantitative analyses on optimal acupuncture conditions such as the stimulation frequency and duration to achieve maximum depressor and bradycardic effects. The aim of the present study was to investigate the effects of varying stimulation frequencies of electroacupuncture on time-dependent changes in blood pressure and heart rate in humans. Twelve healthy volunteers participated in the study. An acupuncture needle was inserted at the Ximen acupoint (PC4 according to WHO nomenclature), located at the anterior aspect of the forearm. An electrical stimulation was delivered through the acupuncture needle at an intensity of 1 V, pulse width of 5 ms, and stimulation frequencies of 0.5, 1, 5, and 10 Hz in a random order. The duration of electroacupuncture was 6 min, during which blood pressure and heart rate responses were monitored. Group-averaged data indicated that 1-Hz electroacupuncture decreased blood pressure and heart rate. Blood pressure was significantly decreased from the prestimulation baseline value of 86.6 ± 2.9 to 81.4 ± 2.3 mmHg during 4-6 min of 1-Hz electroacupuncture (mean ± SE, P < 0.01). Heart rate was also significantly decreased (from 66.2 ± 2.0 to 62.7 ± 1.7 beats/min, P < 0.01). These results provide fundamental evidence that bradycardiac and depressor responses are effectively produced by electrical acupuncture in humans.
Kawada, Toru; Zheng, Can; Yanagiya, Yusuke; Uemura, Kazunori; Miyamoto, Tadayoshi; Inagaki, Masashi; Shishido, Toshiaki; Sugimachi, Masaru; Sunagawa, Kenji
2002-03-01
A transfer function from baroreceptor pressure input to sympathetic nerve activity (SNA) shows derivative characteristics in the frequency range below 0.8 Hz in rabbits. These derivative characteristics contribute to a quick and stable arterial pressure (AP) regulation. However, if the derivative characteristics hold up to heart rate frequency, the pulsatile pressure input will yield a markedly augmented SNA signal. Such a signal would saturate the baroreflex signal transduction, thereby disabling the baroreflex regulation of AP. We hypothesized that the transfer gain at heart rate frequency would be much smaller than that predicted from extrapolating the derivative characteristics. In anesthetized rabbits (n = 6), we estimated the neural arc transfer function in the frequency range up to 10 Hz. The transfer gain was lost at a rate of -20 dB/decade when the input frequency exceeded 0.8 Hz. A numerical simulation indicated that the high-cut characteristics above 0.8 Hz were effective to attenuate the pulsatile signal and preserve the open-loop gain when the baroreflex dynamic range was finite.
[Sinus rhythm: mechanisms and function].
Lerebours, Guy
2007-01-01
The normal cardiac rhythm originates in a specialized region of the heart, the sinus node that is part of the nodal tissue. The rhythmic, impulse initiation of sinus node pacemaker cells results from a spontaneous diastolic depolarization that is initiated immediately after repolarization of the preceding actions potential. This slow diastolic depolarisation is typical of automatic cells and essential to their function. Several currents are involved in this diastolic depolarisation: a hyperpolarization activated inward current, termed "pacemaker" I(f) current, two Ca2+ currents (a L type and a T type), a delayed K+ current and a Na/Ca exchange current. The frequency of the automatic discharge is the main determinant of heart rate. However the sinus node activity is regulated by adrenergic and cholinergic neurotransmitters. Acetylcholine provokes the hyperpolarization of pacemaker cells and decreases the speed of the spontaneous diastolic depolarisation, thus slowing the sinus rate. Catecholamines lead to sinus tachycardia by increasing the diastolic depolarisation speed. In normal conditions, the observed resting heart rate is lower than the intrinsic frequency of the sinus node due to a "predominance" of the vagal tone. Neural regulation of the heart rate aims at meeting the metabolic needs of the tissues through a varying blood flow. Differences between diurnal and nocturnal mean heart rates are accounted for by neural influences. During the night, the increased vagal tone results in decreased heart rate. The exercise-induced tachycardia results from the sympathetic stimulation. It allows more blood to reach skeletal muscles, and as a consequence an increased supply of oxygen and nutrients. Compared to the variety of clinical arrhythmias, sinus rhythm is the basis for optimal exercise capacity and quality of life.
Dissociation of heart rate variability and heart rate recovery in well-trained athletes.
Lee, C Matthew; Mendoza, Albert
2012-07-01
The purpose of this investigation was to examine the relationships between aerobic fitness, volume of physical activity (PA), heart rate variability (HRV), and heart rate recovery (HRR) in a group of well-trained endurance athletes. Nineteen endurance athletes participated in this study and had aerobic capacities that placed them above the 99th percentile based on normative values (VO(2max): 67.1 ± 2 ml kg(-1) min(-1)). HRV was obtained via an EKG collected during supine rest and reported as high-frequency (HF), low-frequency (LF), and total power (TP). Natural log (ln) transformation was applied when variables violated assumptions of normality. HRR recovery was reported as the reduction in heart rate from peak exercise to the heart rate 1 min after cessation of exercise and PA was estimated from a questionnaire. HRR was significantly correlated with PA and VO(2max) (r = 0.67, P = 0.003 and 0.51, P = 0.039, respectively), but not with any index of HRV. Age was significantly correlated with lnHF (r = -0.49, P = 0.033), lnLF/lnHF (r = 0.48, P = 0.037), and normalized units (NU) of LF (r = 0.47, P = 0.042) and HF (r = -0.47, P = 0.042). Stepwise regression revealed that the strongest predictor of HRR was PA (R (2) = 0.45) and that VO(2max) did not add significant predictive value to the model. The relationship between HRV and age is evident in well-trained endurance athletes, whereas the relationship between HRV and PA/aerobic fitness is not. The maintained relationship between HRR and PA/aerobic fitness suggests that HRR may be a better marker of fitness-related differences in autonomic control in this population.
Maturation of Heart Rate and Blood Pressure Variability during Sleep in Term-Born Infants
Yiallourou, Stephanie R.; Sands, Scott A.; Walker, Adrian M.; Horne, Rosemary S.C.
2012-01-01
Study Objectives: Abnormal blood pressure control is implicated in the sudden infant death syndrome (SIDS). However, no data exist on normal development of blood pressure control during infancy. This study assessed maturation of autonomic control of blood pressure and heart rate during sleep within the first 6 months of life. Participants: Term infants (n = 31) were studied longitudinally at 2-4 weeks, 2-3 months, and 5-6 months postnatal age. Interventions: Infants underwent daytime polysomnography at each age studied. Blood pressure and heart rate were recorded during quiet (QS) and active (AS) sleep in undisturbed baseline and head-up tilt conditions. Measurements and Results: Autonomic control was assessed using spectral indices of blood pressure and heart rate variability (BPV and HRV) in ranges of low frequency (LF, reflecting sympathetic + parasympathetic activity) and high frequency (HF, parasympathetic activity), total power (LF+HF), and LF/HF ratio (sympathovagal balance). With increasing postnatal age and predominantly during QS, HRV-LF, HRV-HF, and HRV total power increased, while HRV-LF/HF decreased. BPV-LF/HF also decreased with postnatal age. All changes were evident in both baseline and head-up tilt conditions. BPV-LF and BPV total power during tilts were markedly reduced in QS versus AS at each age. Conclusions: In sleeping infants, sympathetic vascular modulation of the circulation decreases with age, while parasympathetic control of heart rate is strengthened. These normative data will aid in the early identification of conditions where autonomic function is impaired, such as in SIDS. Citation: Yiallourou SR; Sands SA; Walker AM; Horne RSC. Maturation of heart rate and blood pressure variability during sleep in term-born infants. SLEEP 2012;35(2):177-186. PMID:22294807
Cardiorespiratory costs of growth in low birth weight infants.
Schulze, K; Kashyap, S; Ramakrishnan, R
1993-02-01
The energy cost of growth includes two components: the energy stored in new tissues and the energy expended in all energy requiring steps associated with nutrient intake and net tissue accretion. Most of the energy expended in growth is accounted for by the energy cost of tissue anabolism: peptide bonds, lipogenesis, substrate transport, etc. However, to the extent that additional work is required of the heart and lungs for growth-related increases in O2 and CO2 transport, increased energy is also expended in cardiorespiratory work. Indirect estimates of these costs can be gained by examining the effects of diet and weight gain on heart rate and respiratory frequency. We studied 66 healthy low birth weight infants, mean study weight = 2010 g, fed constant intakes of protein (2.25-3.9 g/kg per day) and energy (100-150 kcal/kg per day). These diets led to rates of weight gain ranging from 13.9 to 21.7 g/kg per day, among the diet groups. Bi-weekly 6-h assessments of energy expenditure, heart rate, respiratory frequency and state of sleep were made after full enteral intake was achieved. After adjustment of heart rate for the effect of postnatal age, heart rate during active sleep was related to weight gain (y = 0.97 x + 144, r2 = 0.15), nitrogen-energy ratio of the diet (y = 5.9 x + 139,2 r2 = 0.22), and energy expenditure (y = 0.53 x + 129, r2 = 0.13). Multiple regression analysis revealed that age-adjusted heart rate during active and quiet sleep was significantly related to a combination of the same three variables (r2 = 0.31).(ABSTRACT TRUNCATED AT 250 WORDS)
O'Connor, Daniel M; Smith, Robert S; Piras, Bryan A; Beyers, Ronald J; Lin, Dan; Hossack, John A; French, Brent A
2016-04-22
Ivabradine selectively inhibits the pacemaker current of the sinoatrial node, slowing heart rate. Few studies have examined the effects of ivabradine on the mechanical properties of the heart after reperfused myocardial infarction (MI). Advances in ultrasound speckle-tracking allow strain analyses to be performed in small-animal models, enabling the assessment of regional mechanical function. After 1 hour of coronary occlusion followed by reperfusion, mice received 10 mg/kg per day of ivabradine dissolved in drinking water (n=10), or were treated as infarcted controls (n=9). Three-dimensional high-frequency echocardiography was performed at baseline and at days 2, 7, 14, and 28 post-MI. Speckle-tracking software was used to calculate intramural longitudinal myocardial strain (Ell) and strain rate. Standard deviation time to peak radial strain (SD Tpeak Err) and temporal uniformity of strain were calculated from short-axis cines acquired in the left ventricular remote zone. Ivabradine reduced heart rate by 8% to 16% over the course of 28 days compared to controls (P<0.001). On day 28 post-MI, the ivabradine group was found to have significantly smaller end-systolic volumes, greater ejection fraction, reduced wall thinning, and greater peak Ell and Ell rate in the remote zone, as well as globally. Temporal uniformity of strain and SD Tpeak Err were significantly smaller in the ivabradine-treated group by day 28 (P<0.05). High-frequency ultrasound speckle-tracking demonstrated decreased left ventricular remodeling and dyssynchrony, as well as improved mechanical performance in remote myocardium after heart rate reduction with ivabradine. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Sakata, K; Yoshimura, N; Tanabe, K; Kito, K; Nagase, K; Iida, H
2017-02-01
Maternal hypotension is a common complication during cesarean section performed under spinal anesthesia. Changes in maternal heart rate with postural changes or values of heart rate variability have been reported to predict hypotension. Therefore, we hypothesized that changes in heart rate variability due to postural changes can predict hypotension. A total of 45 women scheduled to undergo cesarean section under spinal anesthesia were enrolled. A postural change test was performed the day before cesarean section. The ratio of the power of low and high frequency components contributing to heart rate variability was assessed in the order of supine, left lateral, and supine. Patients who exhibited a ⩾two-fold increase in the low-to-high frequency ratio when moving to supine from the lateral position were assigned to the postural change test-positive group. According to the findings of the postural change test, patients were assigned to the positive (n=22) and negative (n=23) groups, respectively. Hypotension occurred in 35/45 patients, of whom 21 (60%) were in the positive group and 14 (40%) were in the negative group. The incidence of hypotension was greater in the positive group (P<0.01). The total dose of ephedrine was greater in the positive group (15±11 vs. 7±7mg, P=0.005). The area under the receiver operating characteristic curve was 0.76 for the postural change test as a predictor of hypotension. The postural change test with heart rate variability analysis may be used to predict the risk of hypotension during spinal anesthesia for cesarean section. Copyright © 2016 Elsevier Ltd. All rights reserved.
Baldi, Emilio; Baldi, Claudio; Lithgow, Brian J
2007-01-01
The question whether pulsed electromagnetic field (PEMF) can affect the heart rhythm is still controversial. This study investigates the effects on the cardiocirculatory system of ELF-PEMFs. It is a follow-up to an investigation made of the possible therapeutic effect ELF-PEMFs, using a commercially available magneto therapeutic unit, had on soft tissue injury repair in humans. Modulation of heart rate (HR) or heart rate variability (HRV) can be detected from changes in periodicity of the R-R interval and/or from changes in the numbers of heart-beat/min (bpm), however, R-R interval analysis gives only a quantitative insight into HRV. A qualitative understanding of HRV can be obtained considering the power spectral density (PSD) of the R-R intervals Fourier transform. In this study PSD is the investigative tool used, more specifically the low frequency (LF) PSD and high frequency (HF) PSD ratio (LF/HF) which is an indicator of sympatho-vagal balance. To obtain the PSD value, variations of the R-R time intervals were evaluated from a continuously recorded ECG. The results show a HR variation in all the subjects when they are exposed to the same ELF-PEMF. This variation can be detected by observing the change in the sympatho-vagal equilibrium, which is an indicator of modulation of heart activity. Variation of the LF/HF PSD ratio mainly occurs at transition times from exposure to nonexposure, or vice versa. Also of interest are the results obtained during the exposure of one subject to a range of different ELF-PEMFs. This pilot study suggests that a full investigation into the effect of ELF-PEMFs on the cardiovascular system is justified.
Bailón, Raquel; Garatachea, Nuria; de la Iglesia, Ignacio; Casajús, Jose Antonio; Laguna, Pablo
2013-07-01
The analysis and interpretation of heart rate variability (HRV) during exercise is challenging not only because of the nonstationary nature of exercise, the time-varying mean heart rate, and the fact that respiratory frequency exceeds 0.4 Hz, but there are also other factors, such as the component centered at the pedaling frequency observed in maximal cycling tests, which may confuse the interpretation of HRV analysis. The objectives of this study are to test the hypothesis that a component centered at the running stride frequency (SF) appears in the HRV of subjects during maximal treadmill exercise testing, and to study its influence in the interpretation of the low-frequency (LF) and high-frequency (HF) components of HRV during exercise. The HRV of 23 subjects during maximal treadmill exercise testing is analyzed. The instantaneous power of different HRV components is computed from the smoothed pseudo-Wigner-Ville distribution of the modulating signal assumed to carry information from the autonomic nervous system, which is estimated based on the time-varying integral pulse frequency modulation model. Besides the LF and HF components, the appearance is revealed of a component centered at the running SF as well as its aliases. The power associated with the SF component and its aliases represents 22±7% (median±median absolute deviation) of the total HRV power in all the subjects. Normalized LF power decreases as the exercise intensity increases, while normalized HF power increases. The power associated with the SF does not change significantly with exercise intensity. Consideration of the running SF component and its aliases is very important in HRV analysis since stride frequency aliases may overlap with LF and HF components.
Effect of low-dose scopolamine on autonomic control of the heart
NASA Technical Reports Server (NTRS)
Raeder, E. A.; Stys, A.; Cohen, R. J.
1997-01-01
Background: In low doses, scopolamine paradoxically enhances parasympathetic outflow to the heart. The mechanisms which mediate this action are not fully understood. Moreover, there are conflicting data regarding the potential role of sympathetic activity. This study in 17 healthy individuals was designed to characterize the influence of low dose transdermal scopolamine on the gain of the baroreflex and respiratory heart rate reflex and to determine the role of sympathetic activity. Methods: The effect of scopolamine was analyzed in the time and frequency domain by computing heart rate variability indices. The gains of the respiratory heart rate reflex and the baroreflex were estimated simultaneously by means of a cardiovascular system identification approach using an optimized autoregressive moving average algorithm. Measurements were repeated in the upright posture to assess the influence of enhanced sympathetic activity. In six subjects ambulatory ECGs were recorded to determine whether there are diurnal variations of the effect of scopolamine. Results: Scopolamine enhances vagal modulation of heart rate through both the respiratory-heart rate reflex and the baroreflex, as the gains of both were augmented by the drug in the supine and in the upright postures. Conclusions: Scopolamine increases parasympathetic cardiac control by augmenting the gain of the respiratory-heart rate and baroreflex. This action is not attenuated in the upright posture when sympathetic tone is increased.
Maturation of heart rate and blood pressure variability during sleep in term-born infants.
Yiallourou, Stephanie R; Sands, Scott A; Walker, Adrian M; Horne, Rosemary S C
2012-02-01
Abnormal blood pressure control is implicated in the sudden infant death syndrome (SIDS). However, no data exist on normal development of blood pressure control during infancy. This study assessed maturation of autonomic control of blood pressure and heart rate during sleep within the first 6 months of life. Term infants (n = 31) were studied longitudinally at 2-4 weeks, 2-3 months, and 5-6 months postnatal age. Infants underwent daytime polysomnography at each age studied. Blood pressure and heart rate were recorded during quiet (QS) and active (AS) sleep in undisturbed baseline and head-up tilt conditions. Autonomic control was assessed using spectral indices of blood pressure and heart rate variability (BPV and HRV) in ranges of low frequency (LF, reflecting sympathetic + parasympathetic activity) and high frequency (HF, parasympathetic activity), total power (LF+HF), and LF/HF ratio (sympathovagal balance). With increasing postnatal age and predominantly during QS, HRV-LF, HRV-HF, and HRV total power increased, while HRV-LF/HF decreased. BPV-LF/HF also decreased with postnatal age. All changes were evident in both baseline and head-up tilt conditions. BPV-LF and BPV total power during tilts were markedly reduced in QS versus AS at each age. In sleeping infants, sympathetic vascular modulation of the circulation decreases with age, while parasympathetic control of heart rate is strengthened. These normative data will aid in the early identification of conditions where autonomic function is impaired, such as in SIDS.
An Investigation of the Effect of Body Mass on Resting Heart Rate in Dogs.
ERIC Educational Resources Information Center
Woodhead, Vanessa; Reiss, Michael
1991-01-01
A student project that investigated the relationship between resting heart beat frequency and body mass of adult dogs is described. The results are compared to those of other mammals and birds. The procedure and results are included. (KR)
The cardiac effects of carbon nanotubes in rat.
Hosseinpour, Mina; Azimirad, Vahid; Alimohammadi, Maryam; Shahabi, Parviz; Sadighi, Mina; Ghamkhari Nejad, Ghazaleh
2016-01-01
Carbon nanotubes (CNTs) are novel candidates in nanotechnology with a variety of increasing applications in medicine and biology. Therefore the investigation of nanomaterials' biocompatibility can be an important topic. The aim of present study was to investigate the CNTs impact on cardiac heart rate among rats. Electrocardiogram (ECG) signals were recorded before and after injection of CNTs on a group with six rats. The heart rate variability (HRV) analysis was used for signals analysis. The rhythm-to-rhythm (RR) intervals in HRV method were computed and features of signals in time and frequency domains were extracted before and after injection. RESULTS of the HRV analysis showed that CNTs increased the heart rate but generally these nanomaterials did not cause serious problem in autonomic nervous system (ANS) normal activities. Injection of CNTs in rats resulted in increase of heart rate. The reason of phenomenon is that multiwall CNTs may block potassium channels. The suppressed and inhibited IK and potassium channels lead to increase of heart rate.
Goshvarpour, Ateke; Goshvarpour, Atefeh
2013-02-01
The human heartbeat is one of the important examples of complex physiologic fluctuations. For the first time in this study higher order spectra of heart rate signals during meditation have explored. Specifically, the aim of this study was to analysis and compares the contribution of quadratic phase coupling of human heart rate variability during two forms of meditation: (1) Chinese Chi (or Qigong) meditation and (2) Kundalini Yoga meditation. For this purpose, Bispectrum was estimated by using biased, parametric and the direct (FFT) method. The results show that the mean Bispectrum magnitude of heart rate signals increased during Kundalini Yoga meditation, but it decreased significantly during Chi meditation. However, in both meditation techniques phase-coupled harmonics are shifted to the higher frequencies during meditation. In addition, it has shown that not only there are significant differences between rest and meditation states, but also heart rate patterns appear to be influenced by different types of meditation.
PIRINTR, Prapawadee; SAENGKLUB, Nakkawee; LIMPRASUTR, Vudhiporn; SAWANGKOON, Suwanakiet; KIJTAWORNRAT, Anusak
2017-01-01
Myxomatous mitral valve degeneration (MMVD) causes an imbalance of sympathovagal activity resulted in poor cardiac outcomes. Phosphodiesterase-5 inhibitors have been revealed cardioprotective effect in patients with heart diseases. This study aimed to 1) compare the heart rate variability (HRV) between asymptomatic MMVD and healthy dogs and 2) assess long-term effects of sildenafil and enalapril on time- and frequency-domains analyzes. Thirty-four dogs with MMVD stage B1 or B2 and thirteen healthy dogs were recruited into the study. MMVD dogs were divided into 3 subgroups: control (n=13), sildenafil (n=12) and enalapril (n=9). HRV was analyzed from 1-hr Holter recording at baseline (D0) in all dogs and at 30, 90 and 180 days after treatment. The results showed that MMVD dogs had significant higher heart rate (HR), systemic blood pressures, the ratio of low to high frequency (LF/HF) and had significant decreased standard deviation of all normal to normal RR intervals (SDNN) and the percentage of the number of normal-to-normal sinus RR intervals with differences >50 msec computed over the entire recording (pNN50) when compared with healthy dogs (P<0.05). Neither time nor frequency domain parameters were different among subgroups of MMVD dogs at D0. After treatment with sildenafil for 90 days, both time- and frequency-domain parameters were significantly increased when compared with control and enalapril groups. This study demonstrated that sildenafil improves HRV in asymptomatic MMVD dogs suggesting that sildenafil should be used in the MMVD dogs to restore the sympathovagal balance. PMID:28717064
A Meta-analysis on Resting State High-frequency Heart Rate Variability in Bulimia Nervosa.
Peschel, Stephanie K V; Feeling, Nicole R; Vögele, Claus; Kaess, Michael; Thayer, Julian F; Koenig, Julian
2016-09-01
Autonomic nervous system function is altered in eating disorders. We aimed to quantify differences in resting state vagal activity, indexed by high-frequency heart rate variability comparing patients with bulimia nervosa (BN) and healthy controls. A systematic search of the literature to identify studies eligible for inclusion and meta-analytical methods were applied. Meta-regression was used to identify potential covariates. Eight studies reporting measures of resting high-frequency heart rate variability in individuals with BN (n = 137) and controls (n = 190) were included. Random-effects meta-analysis revealed a sizeable main effect (Z = 2.22, p = .03; Hedge's g = 0.52, 95% CI [0.06;0.98]) indicating higher resting state vagal activity in individuals with BN. Meta-regression showed that body mass index and medication intake are significant covariates. Findings suggest higher vagal activity in BN at rest, particularly in unmedicated samples with lower body mass index. Potential mechanisms underlying these findings and implications for routine clinical care are discussed. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association.
Association between heart rhythm and cortical sound processing.
Marcomini, Renata S; Frizzo, Ana Claúdia F; de Góes, Viviane B; Regaçone, Simone F; Garner, David M; Raimundo, Rodrigo D; Oliveira, Fernando R; Valenti, Vitor E
2018-04-26
Sound signal processing signifies an important factor for human conscious communication and it may be assessed through cortical auditory evoked potentials (CAEP). Heart rate variability (HRV) provides information about heart rate autonomic regulation. We investigated the association between resting HRV and CAEP. We evaluated resting HRV in the time and frequency domain and the CAEP components. The subjects remained at rest for 10 minutes for HRV recording, then they performed the CAEP examinations through frequency and duration protocols in both ears. Linear regression indicated that the amplitude of the N2 wave of the CAEP in the left ear (not right ear) was significantly influenced by standard deviation of normal-to-normal RR-intervals (17.7%) and percentage of adjacent RR-intervals with a difference of duration greater than 50 milliseconds (25.3%) time domain HRV indices in the frequency protocol. In the duration protocol and in the left ear the latency of the P2 wave was significantly influenced by low (LF) (20.8%) and high frequency (HF) bands in normalized units (21%) and LF/HF ratio (22.4%) indices of HRV spectral analysis. The latency of the N2 wave was significantly influenced by LF (25.8%), HF (25.9%) and LF/HF (28.8%). In conclusion, we promote the supposition that resting heart rhythm is associated with thalamo-cortical, cortical-cortical and auditory cortex pathways involved with auditory processing in the right hemisphere.
Hernando, David; Hernando, Alberto; Casajús, Jose A; Laguna, Pablo; Garatachea, Nuria; Bailón, Raquel
2018-05-01
Standard methodologies of heart rate variability analysis and physiological interpretation as a marker of autonomic nervous system condition have been largely published at rest, but not so much during exercise. A methodological framework for heart rate variability (HRV) analysis during exercise is proposed, which deals with the non-stationary nature of HRV during exercise, includes respiratory information, and identifies and corrects spectral components related to cardiolocomotor coupling (CC). This is applied to 23 male subjects who underwent different tests: maximal and submaximal, running and cycling; where the ECG, respiratory frequency and oxygen consumption were simultaneously recorded. High-frequency (HF) power results largely modified from estimations with the standard fixed band to those obtained with the proposed methodology. For medium and high levels of exercise and recovery, HF power results in a 20 to 40% increase. When cycling, HF power increases around 40% with respect to running, while CC power is around 20% stronger in running.
Laumbach, Robert J.; Rich, David Q.; Gandhi, Sampada; Amorosa, Louis; Schneider, Stephen; Zhang, Junfeng; Ohman-Strickland, Pamela; Gong, Jicheng; Lelyanov, Oleksiy; Kipen, Howard M.
2014-01-01
Objective To pilot a protocol to evaluate acute cardiovascular effects in in-vehicle exposure to traffic air pollutants in people with diabetes. Methods Twenty-one volunteers with type 2 diabetes were passengers on 90- to 110-minute car rides on a busy highway. We measured in-vehicle particle number and mass (PM2.5) nitrogen dioxide, and carbon monoxide and heart rate, heart rate variability (HRV), and blood pressure. Results Compared with pre-ride measurements, we found a decrease in high frequency (HF) HRV from pre-ride to next day (ratio 0.66, 95% CI = 0.47 to 0.93) and an increase in low frequency to HF ratio at post-ride (ratio 1.92, 95% CI = 1.21 to 3.05) at post-ride. Interquartile range increases in measured pollutants were associated with next-day decreases in HR HRV. Conclusions This protocol appears useful for assessing acute adverse cardiovascular effects of in-vehicle exposures among people who have diabetes. PMID:20190650
Schulze, J; Troeger, C
2010-02-01
The complex regional pain syndrome type I (CRPS I) is a painful neuropathic disorder with an antecedent disproportionate trauma leading to spontaneous pain, hyperalgesia, impaired motor function, swelling, changes in sweating and vascular abnormalities without nerve injury. Whether this syndrome is the result of central or peripheral autonomic dysfunction is still a matter of debate. The purpose of this study was to determine the activity of the sympathetic nervous system in patients with CRPS I by power spectral analysis of heart rate variability. This is a pilot study on 6 patients (mean age 50 years; 4 female, 2 male) diagnosed as suffering from CRPS I and 6 age-matched healthy controls. In the pain-free interval and after taking rest for 5 min, 512 subsequent heart beats were obtained with an ECG standard lead II in the supine and then sitting position. Using an autoregressive model, power spectral densities were calculated for the following frequency bands: <0.040 Hz (very low frequency; VLF), 0.040-0.150 Hz (low frequency; LF) and 0.150-0.4 Hz (high frequency; HF). The sympatho-vagal balance is expressed by the ratio of the low-frequency component (LF) to the high-frequency component (HF) of the power spectrum. Significant differences in the mean LF/HF ratios were found in the patients with CRPS I compared to the healthy controls in the supine position (LF/HF=4.01 vs. LF/HF=1.27; p=0.041). The application of stress by changing to the sitting position even increased that difference (6.72 vs. 1.93). Our results support the hypothesis that the pathogenesis of the early stage CRPS I might be related to an increased sympathetic activity. By assessing the autonomic influence on the heart rate variability in CRPS I patients we could also conclude that this disturbance occurs rather at a central level. Georg Thieme Verlag KG Stuttgart, New York.
Koelsch, Stefan; Jäncke, Lutz
2015-11-21
Music can powerfully evoke and modulate emotions and moods, along with changes in heart activity, blood pressure (BP), and breathing. Although there is great heterogeneity in methods and quality among previous studies on effects of music on the heart, the following findings emerge from the literature: Heart rate (HR) and respiratory rate (RR) are higher in response to exciting music compared with tranquilizing music. During musical frissons (involving shivers and piloerection), both HR and RR increase. Moreover, HR and RR tend to increase in response to music compared with silence, and HR appears to decrease in response to unpleasant music compared with pleasant music. We found no studies that would provide evidence for entrainment of HR to musical beats. Corresponding to the increase in HR, listening to exciting music (compared with tranquilizing music) is associated with a reduction of heart rate variability (HRV), including reductions of both low-frequency and high-frequency power of the HRV. Recent findings also suggest effects of music-evoked emotions on regional activity of the heart, as reflected in electrocardiogram amplitude patterns. In patients with heart disease (similar to other patient groups), music can reduce pain and anxiety, associated with lower HR and lower BP. In general, effects of music on the heart are small, and there is great inhomogeneity among studies with regard to methods, findings, and quality. Therefore, there is urgent need for systematic high-quality research on the effects of music on the heart, and on the beneficial effects of music in clinical settings. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Ontogeny and control of the heart rate power spectrum in the last third of gestation in fetal sheep.
Koome, Miriam E; Bennet, Laura; Booth, Lindsea C; Davidson, Joanne O; Wassink, Guido; Gunn, Alistair Jan
2014-01-01
Power spectral analysis of fetal heart rate variability has been proposed to provide a non-invasive estimate of autonomic balance. However, there are few systematic data before birth. We therefore examined developmental changes in the frequency power spectrum at very low (0-0.04 Hz), low (0.04-0.15 Hz) and high frequencies (0.15-0.4 Hz), as well as the ratio of low- to high-frequency power (LF/HF), in chronically catheterized, healthy fetal sheep at 0.6 (n = 8), 0.7 (n = 7) and 0.8 gestational age (ga; n = 11). In a second study, 0.8 ga fetuses received either atropine (4.8 mg bolus, then 4.8 mg h(-1) for 30 min, n = 6) or 6-hydroxydopamine (20 mg ml(-1) at 2.5 ml h(-1) for 3 h; n = 9). Data were analysed by sleep state, defined by low-voltage-high-frequency (LV) or high-voltage-low-frequency (HV) EEG. Total spectral power increased with gestational age (P < 0.05), while LF/HF decreased from 0.6 to 0.7 ga. At 0.8 ga, heart rate and LF/HF were significantly higher during HV than LV sleep (P < 0.05). Consistent with this, although total spectral power was not significantly greater during HV sleep, there was a significant interaction between sleep state and frequency band (P = 0.02). Both atropine (P = 0.05) and 6-hydroxydopamine (P < 0.05) were associated with an overall reduction in spectral power but no significant effect on the LF/HF ratio. This study does not support substantial, consistent differences between the frequencies of sympathetic and parasympathetic activity in late-gestation fetal sheep.
Physiological Effects of Touching Coated Wood.
Ikei, Harumi; Song, Chorong; Miyazaki, Yoshifumi
2017-07-13
This study examined the physiological effects of touching wood with various coating with the palm of the hand on brain activity and autonomic nervous activity. Participants were 18 female university students (mean age, 21.7 ± 1.6 years). As an indicator of brain activity, oxyhemoglobin concentrations were measured in the left and right prefrontal cortices using near-infrared time-resolved spectroscopy. Heart rate variability (HRV) and heart rate were used as indicators of autonomic nervous activity. The high-frequency (HF) component of HRV, which reflects parasympathetic nervous activity, and the low-frequency (LF)/HF ratio, which reflects sympathetic nervous activity, were measured. Plates of uncoated, oil-finished, vitreous-finished, urethane-finished, and mirror-finished white oak wood were used as tactile stimuli. After sitting at rest with their eyes closed for 60 s, participants touched the stimuli with their palm for 90 s each. The results indicated that tactile stimulation with uncoated wood calmed prefrontal cortex activity (vs. urethane finish and mirror finish), increased parasympathetic nervous activity (vs. vitreous finish, urethane finish, and mirror finish), and decreased heart rate (vs. mirror finish), demonstrating a physiological relaxation effect. Further, tactile stimulation with oil- and vitreous-finished wood calmed left prefrontal cortex activity and decreased heart rate relative to mirror-finished wood.
Panayiotou, Georgia; Constantinou, Elena
2017-09-01
Alexithymia is associated with deficiencies in recognizing and expressing emotions and impaired emotion regulation, though few studies have verified the latter assertion using objective measures. This study examined startle reflex modulation by fearful imagery and its associations with heart rate variability in alexithymia. Fifty-four adults (27 alexithymic) imagined previously normed fear scripts. Startle responses were assessed during baseline, first exposure, and reexposure. During first exposure, participants, in separate trials, engaged in either shallow or deep emotion processing, giving emphasis on descriptive or affective aspects of imagery, respectively. Resting heart rate variability was assessed during 2 min of rest prior to the experiment, with high alexithymic participants demonstrating significantly higher LF/HF (low frequency/high frequency) ratio than controls. Deep processing was associated with nonsignificantly larger and faster startle responses at first exposure for alexithymic participants. Lower LF/HF ratio, reflecting higher parasympathetic cardiac activity, predicted greater startle amplitude habituation for alexithymia but lower habituation for controls. Results suggest that, when exposed to prolonged threat, alexithymics may adjust poorly, showing a smaller initial defensive response but slower habituation. This pattern seems related to their low emotion regulation ability as indexed by heart rate variability. © 2017 Society for Psychophysiological Research.
Physiological Effects of Touching Coated Wood
2017-01-01
This study examined the physiological effects of touching wood with various coating with the palm of the hand on brain activity and autonomic nervous activity. Participants were 18 female university students (mean age, 21.7 ± 1.6 years). As an indicator of brain activity, oxyhemoglobin concentrations were measured in the left and right prefrontal cortices using near-infrared time-resolved spectroscopy. Heart rate variability (HRV) and heart rate were used as indicators of autonomic nervous activity. The high-frequency (HF) component of HRV, which reflects parasympathetic nervous activity, and the low-frequency (LF)/HF ratio, which reflects sympathetic nervous activity, were measured. Plates of uncoated, oil-finished, vitreous-finished, urethane-finished, and mirror-finished white oak wood were used as tactile stimuli. After sitting at rest with their eyes closed for 60 s, participants touched the stimuli with their palm for 90 s each. The results indicated that tactile stimulation with uncoated wood calmed prefrontal cortex activity (vs. urethane finish and mirror finish), increased parasympathetic nervous activity (vs. vitreous finish, urethane finish, and mirror finish), and decreased heart rate (vs. mirror finish), demonstrating a physiological relaxation effect. Further, tactile stimulation with oil- and vitreous-finished wood calmed left prefrontal cortex activity and decreased heart rate relative to mirror-finished wood. PMID:28703777
Effects of autogenic training on stress response and heart rate variability in nursing students.
Lim, Seung-Joo; Kim, Chunmi
2014-12-01
This study was undertaken to confirm the effects of autogenic training (AT) on stress response and heart rate variability in nursing school students experiencing stress related to clinical training. The study was carried out from September 2012 to April 2013 in a quasi-experimental nonequivalent control group using a pretest-posttest design. The participants were 40 nursing students in their third year at either of two nursing colleges. All consented to participate. Nineteen nursing students at one college were assigned to the experimental group and underwent the 8-week AT program, and the other 21 were assigned to the control group and did not undergo any training. Stress response was assessed by questionnaire and HRV was measured three times, that is, before the program, at the end of the program, and 6 months after the end of the AT program. A significant time/group interaction was found for stress response (F = 4.68, p = .012), a subjective indicator. However, no significant interaction was found for the objective indicators of heart rate variability, normalized low frequency (F = 2.59, p = .090), normalized high frequency (F = 2.59, p = .090), or low frequency to high frequency ratio (F = 1.38, p = .257). The results suggest that AT provides an acceptable approach to stress reduction in nursing students. Copyright © 2014. Published by Elsevier B.V.
Autonomic Impairment in Severe Traumatic Brain Injury: A Multimodal Neuromonitoring Study.
Sykora, Marek; Czosnyka, Marek; Liu, Xiuyun; Donnelly, Joseph; Nasr, Nathalie; Diedler, Jennifer; Okoroafor, Francois; Hutchinson, Peter; Menon, David; Smielewski, Peter
2016-06-01
Autonomic impairment after acute traumatic brain injury has been associated independently with both increased morbidity and mortality. Links between autonomic impairment and increased intracranial pressure or impaired cerebral autoregulation have been described as well. However, relationships between autonomic impairment, intracranial pressure, impaired cerebral autoregulation, and outcome remain poorly explored. Using continuous measurements of heart rate variability and baroreflex sensitivity we aimed to test whether autonomic markers are associated with functional outcome and mortality independently of intracranial variables. Further, we aimed to evaluate the relationships between autonomic functions, intracranial pressure, and cerebral autoregulation. Retrospective analysis of a prospective database. Neurocritical care unit in a university hospital. Sedated patients with severe traumatic brain injury. Waveforms of intracranial pressure and arterial blood pressure, baseline Glasgow Coma Scale and 6 months Glasgow Outcome Scale were recorded. Baroreflex sensitivity was assessed every 10 seconds using a modified cross-correlational method. Frequency domain analyses of heart rate variability were performed automatically every 10 seconds from a moving 300 seconds of the monitoring time window. Mean values of baroreflex sensitivity, heart rate variability, intracranial pressure, arterial blood pressure, cerebral perfusion pressure, and impaired cerebral autoregulation over the entire monitoring period were calculated for each patient. Two hundred and sixty-two patients with a median age of 36 years entered the analysis. The median admission Glasgow Coma Scale was 6, the median Glasgow Outcome Scale was 3, and the mortality at 6 months was 23%. Baroreflex sensitivity (adjusted odds ratio, 0.9; p = 0.02) and relative power of a high frequency band of heart rate variability (adjusted odds ratio, 1.05; p < 0.001) were individually associated with mortality, independently of age, admission Glasgow Coma Scale, intracranial pressure, pressure reactivity index, or cerebral perfusion pressure. Baroreflex sensitivity showed no correlation with intracranial pressure or cerebral perfusion pressure; the correlation with pressure reactivity index was strong in older patients (age, > 60 yr). The relative power of high frequency correlated significantly with intracranial pressure and cerebral perfusion pressure, but not with pressure reactivity index. The relative power of low frequency correlated significantly with pressure reactivity index. Autonomic impairment, as measured by heart rate variability and baroreflex sensitivity, is significantly associated with increased mortality after traumatic brain injury. These effects, though partially interlinked, seem to be independent of age, trauma severity, intracranial pressure, or autoregulatory status, and thus represent a discrete phenomenon in the pathophysiology of traumatic brain injury. Continuous measurements of heart rate variability and baroreflex sensitivity in the neuromonitoring setting of severe traumatic brain injury may carry novel pathophysiological and predictive information.
Zhao, Jing; He, Fei; Hu, Da-yi; Ding, Rong-jing; Yu, Xiao-jun; Wang, Long; Zhang, Ping; Li, Xue-bin; Guo, Ji-hong; Liu, Wen-ling; Li, Cui-lan; Li, Lei; Gao, Chuan-yu; Zhao, Luo-sha; Chu, Ying-jie; Huang, Zhen-wen; Wei, Jing-han; Hua, Shao-hua; Liu, Rui-yun; Zhuang, Xiao-feng
2013-05-01
To investigate the basic characteristics of passive smoking population, and the impact of passive smoking on heart rate variability, heart rate and blood pressure. Eighty-six passive smokers [mean age: (52.4 ± 7.6) years] were recruited from patients and their relatives who visited cardiovascular outpatient department and excluded structural heart disease between June 2010 and June 2012, 80 normal subjects who were not exposed to smoking served as controls. Questionnaire survey, 24 hours ambulatory electrocardiogram examination and blood pressure measurement were performed in all recruited subjects. (1) Non-marriage rate [18.60% (16/86) vs. 3.75% (3/80), P < 0.01] was significantly higher while education level were significantly lower in passive smoking group than in control group. Passive smokers were more likely service industry workers [29.07% (25/86) vs. 15.00% (12/80), P < 0.05] and had longer daily working time [(7.56 ± 1.24) h vs. (6.02 ± 0.96) h, P < 0.01], and were less likely to be professional technology industry employers [20.93% (18/86) vs. 36.25% (29/80), P < 0.05] and managers [13.95% (12/86) vs. 38.75% (31/80), P < 0.01] compared to controls. The main place of passive smoking was workplace (67.44%, 58/86), entertainment venues (63.95%,55/86), restaurants (48.84%, 42/86). (2) Standard of the normal sinus RR intervals (SDNN), the normal consecutive sinus RR interval difference between the root-mean-square (rMSSD) and adjacent the difference between the RR interval>50 ms the number of share the percentage (PNN50) were significantly lower in passive smoking group than in the control group (all P < 0.05). Every 5 min average of the standard deviation of sinus RR cycle (SDNN index) and 24 h every 5 min sinus RR interval mean standard deviation (SDANN) were similar between the 2 groups (all P > 0.05). Ultra-low-frequency power (VLF), low frequency power (LF), high frequency power (HF) and LF/HF were significantly lower in passive smoking group than in the control group (all P < 0.01). (3) Heart rate and diastolic blood pressure were significantly higher in passive smoking group than in control group (all P < 0.05) while systolic blood pressure was similar between the 2 groups (P > 0.05). Marriage status, education level, profession and daily working time are independent determinants for passive smoking. Passive smoking mainly occurred in the workplace, entertainment venues and restaurants. Passive smoking is linked with reduced heart rate variability, increased 24 h average heart rate and diastolic blood pressure.
Shin, Young-San; Wee, Jae-Kyung; Song, Inchae; Lee, Seongsoo
2015-01-01
Heart rate monitoring is useful to detect many cardiovascular diseases. It can be implemented in a small device with low power consumption, and it can exploit low-cost piezoelectric pressure sensors to measure heart rate. However, it is also desirable to transmit heartbeat waveform for emergency treatment, which significantly increases transmission power. In this paper, a low-cost wireless heart condition monitoring SoC is proposed. It can monitor and transmit both heart rate and heartbeat waveform, but the hardware is extremely simplified to achieve in a small package. By slight modification of successive-approximation analog-digital converter, it can count heart rate and read out heartbeat waveform with the same hardware. In the normal mode, only an 8-bit heart rate is transmitted for power reduction. If the heart rate is out of a given range, it goes to the emergency mode and a 10-bit heartbeat waveform is transmitted for fast treatment. The fabricated chip size is 1.1 mm2 in 0.11 μ m CMOS technology, including the radio-frequency transmitter. The measured power consumption is 161.8 μ W in normal mode and 507.3 μ W in emergency mode, respectively. The proposed SoC achieves low-cost, small area, and low-power. It is useful as part of a disposable healthcare system.
A novel heart rate control model provides insights linking LF-HRV behavior to the open-loop gain.
Dvir, Hila; Bobrovsky, Ben Zion; Gabbay, Uri
2013-09-20
Low-frequency heart rate variability (LF-HRV) at rest has already been successfully modeled as self-sustained oscillations in a nonlinear control loop, but these models fail to simulate LF-HRV decreases either during aerobic exercise or in heart failure patients. Following control engineering practices, we assume the existence of a biological excitation (dither) within the heart rate control loop that softens the nonlinearity and studied LF-HRV behavior in a dither-embedded model. We adopted the Ottesen model with some revisions and induced a dither of high-frequency stochastic perturbations. We simulated scenarios of a healthy subject at rest and during aerobic exercise (by decreasing peripheral vascular resistance) and a heart failure patient (by decreasing stroke volume). The simulations resembled physiological LF-HRV behavior, i.e., LF-HRV decreased during aerobic exercise and in the heart failure patient. The simulations exhibited LF-HRV dependency on the open-loop gain, which is related to the product of the feedback gain and the feed forward gain. We are the first to demonstrate that LF-HRV may be dependent on the open-loop gain. Accordingly, reduced open-loop gain results in decreased LF-HRV, and vice versa. Our findings explain a well-known but unexplained observed phenomenon of reduced LF-HRV both in heart failure patients and in healthy subjects performing aerobic exercise. These findings have implications on how changes in LF-HRV can be interpreted physiologically, a necessary step towards the clinical utilization of LF-HRV. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure.
Turianikova, Zuzana; Javorka, Kamil; Baumert, Mathias; Calkovska, Andrea; Javorka, Michal
2011-09-01
Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1-10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change.
Curilem Gatica, Cristian; Almagià Flores, Atilio; Yuing Farías, Tuillang; Rodríguez Rodríguez, Fernando
2014-07-01
Body composition is a non-invasive method, which gives us information about the distribution of tissues in the body structure, it is also an indicator of the risk of mortality in patients with chronic obstructive pulmonary disease. The heart rate variability is a technique that gives us information of autonomic physiological condition, being recognized as an indicator which is decreased in a number of diseases. The purpose of this study was to assess body composition and heart rate variability. The methodology used is that of Debora Kerr (1988) endorsed by the International Society for advances in Cineantropometría for body composition and heart rate variability of the guidelines described by the American Heart Association (1996). Roscraff equipment, caliper Slimguide and watch Polar RS 800CX was used. , BMI 26.7 ± 3.9 kg / m²; Muscle Mass 26.1 ± 6.3 kg ; Bone Mass 1.3 kg ± 8.1 76 ± 9.9 years Age : 14 candidates for pulmonary rehabilitation patients were evaluated , Adipose mass 16.4 ± 3.6 kg ; FEV1 54 ± 14%. Increased waist circumference and waist hip ratio was associated with a lower overall heart rate variability. The bone component was positively related to the variability of heart rate and patients with higher forced expiratory volume in one second had lower high frequency component in heart rate variability. In these patients, the heart rate variability is reduced globally and is associated with cardiovascular risk parameters. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
NASA Astrophysics Data System (ADS)
Aerts, Wouter; Joosen, Pieter; Widjaja, Devy; Varon, Carolina; Vandeput, Steven; Van Huffel, Sabine; Aubert, Andre E.
2013-02-01
Gravity changes during partial-G parabolic flights (0g -0.16g - 0.38g) lead to changes in modulation of the autonomic nervous system (ANS), studied via the heart rate variability (HRV) and blood pressure variability (BPV). HRV and BPV were assessed via classical time and frequency domain measures. Mean systolic and diastolic blood pressure show both increasing trends towards higher gravity levels. The parasympathetic and sympathetic modulation show both an increasing trend with decreasing gravity, although the modulation is sympathetic predominant during reduced gravity. For the mean heart rate, a non-monotonic relation was found, which can be explained by the increased influence of stress on the heart rate. This study shows that there is a relation between changes in gravity and modulations in the ANS. With this in mind, countermeasures can be developed to reduce postflight orthostatic intolerance.
Diminished heart rate complexity in adolescent girls: a sign of vulnerability to anxiety disorders?
Fiol-Veny, Aina; De la Torre-Luque, Alejandro; Balle, Maria; Bornas, Xavier
2018-07-01
Diminished heart rate variability has been found to be associated with high anxiety symptomatology. Since adolescence is the period of onset for many anxiety disorders, this study aimed to determine sex- and anxiety-related differences in heart rate variability and complexity in adolescents. We created four groups according to sex and anxiety symptomatology: high-anxiety girls (n = 24) and boys (n = 25), and low-anxiety girls (n = 22) and boys (n = 24) and recorded their cardiac function while they performed regular school activities. A series of two-way (sex and anxiety) MANOVAs were performed on time domain variability, frequency domain variability, and non-linear complexity. We obtained no multivariate interaction effects between sex and anxiety, but highly anxious participants had lower heart rate variability than the low-anxiety group. Regarding sex, girls showed lower heart rate variability and complexity than boys. The results suggest that adolescent girls have a less flexible cardiac system that could be a marker of the girls' vulnerability to developing anxiety disorders.
Liu, Yun; Scirica, Benjamin M; Stultz, Collin M; Guttag, John V
2016-10-06
Frequency domain measures of heart rate variability (HRV) are associated with adverse events after a myocardial infarction. However, patterns in the traditional frequency domain (measured in Hz, or cycles per second) may capture different cardiac phenomena at different heart rates. An alternative is to consider frequency with respect to heartbeats, or beatquency. We compared the use of frequency and beatquency domains to predict patient risk after an acute coronary syndrome. We then determined whether machine learning could further improve the predictive performance. We first evaluated the use of pre-defined frequency and beatquency bands in a clinical trial dataset (N = 2302) for the HRV risk measure LF/HF (the ratio of low frequency to high frequency power). Relative to frequency, beatquency improved the ability of LF/HF to predict cardiovascular death within one year (Area Under the Curve, or AUC, of 0.730 vs. 0.704, p < 0.001). Next, we used machine learning to learn frequency and beatquency bands with optimal predictive power, which further improved the AUC for beatquency to 0.753 (p < 0.001), but not for frequency. Results in additional validation datasets (N = 2255 and N = 765) were similar. Our results suggest that beatquency and machine learning provide valuable tools in physiological studies of HRV.
Aksentijević, Dunja; Lewis, Hannah R.
2016-01-01
New Findings What is the central question of this study? Rate–pressure product (RPP) is commonly used as an index of cardiac ‘effort’. In canine and human hearts (which have a positive force–frequency relationship), RPP is linearly correlated with oxygen consumption and has therefore been widely adopted as a species‐independent index of cardiac work. However, given that isolated rodent hearts demonstrate a negative force–frequency relationship, its use in this model requires validation. What is the main finding and its importance? Despite its widespread use, RPP is not correlated with oxygen consumption (or cardiac ‘effort’) in the Langendorff‐perfused isolated rat heart. This lack of correlation was also evident when perfusions included a range of metabolic substrates, insulin or β‐adrenoceptor stimulation. Langendorff perfusion of hearts isolated from rats and mice has been used extensively for physiological, pharmacological and biochemical studies. The ability to phenotype these hearts reliably is, therefore, essential. One of the commonly used indices of function is rate–pressure product (RPP); a rather ill‐defined index of ‘work’ or, more correctly, ‘effort’. Rate–pressure product, as originally described in dog or human hearts, was shown to be correlated with myocardial oxygen consumption (MV˙O2). Despite its widespread use, the application of this index to rat or mouse hearts (which, unlike the dog or human, have a negative force–frequency relationship) has not been characterized. The aim of this study was to examine the relationship between RPP and MV˙O2 in Langendorff‐perfused rat hearts. Paced hearts (300–750 beats min−1) were perfused either with Krebs–Henseleit (KH) buffer (11 mm glucose) or with buffer supplemented with metabolic substrates and insulin. The arteriovenous oxygen consumption (MV˙O2) was recorded. Metabolic status was assessed using 31P magnetic resonance spectroscopy and lactate efflux. Experiments were repeated in the presence of isoprenaline and in unpaced hearts where heart rate was increased by cumulative isoprenaline challenge. In KH buffer‐perfused hearts, MV˙O2 increased with increasing heart rate, but given that left ventricular developed pressure decreased with increases in rate, RPP was not correlated with MV˙O2, lactate production or phosphocreatine/ATP ratio. Although the provision of substrates or β‐adrenoceptor stimulation changed the shape of the RPP–MV˙O2 relationship, neither intervention resulted in a positive correlation between RPP and oxygen consumption. Rate–pressure product is therefore an unreliable index of oxygen consumption or ‘cardiac effort’ in the isolated rat heart. PMID:26585840
Measurement of heart sounds with EMFi transducer.
Kärki, Satu; Kääriäinen, Minna; Lekkala, Jukka
2007-01-01
A measurement system for heart sounds was implemented by using ElectroMechanical Film (EMFi). Heart sounds are produced by the vibrations of the cardiac structure. An EMFi transducer attached to the skin of the chest wall converts these mechanical vibrations into an electrical signal. Furthermore, the signal is amplified and transmitted to the computer. The data is analyzed with Matlab software. The low-frequency components of the measured signal (respiration and pulsation of the heart) are filtered out as well as the 50 Hz noise. Also the power spectral density (PSD) plot is computed. In test measurements, the signal was measured with respiration and by holding breath. From the filtered signal, the first (S1) and the second (S2) heart sound can be clearly seen in both cases. In addition, from the raw data signals the respiration frequency and the heart rate can be determined. In future applications, with the EMFi material it is possible to implement a plaster-like transducer measuring vital signals.
Prinsloo, Gabriell E; Derman, Wayne E; Lambert, Michael I; Laurie Rauch, H G
2013-06-01
This study examines the acute effect of heart rate variability (HRV) biofeedback on HRV measures during and immediately after biofeedback and during the following laboratory-induced stress. Eighteen healthy males exposed to work-related stress were randomised into an HRV biofeedback group (BIO) or a comparative group (COM). Subjects completed a modified Stroop task before (Stroop 1) and after (Stroop 2) the intervention. Both groups had similar physiological responses to stress in Stroop 1. In Stroop 2, the COM group responded similarly to the way they did to Stroop 1: respiratory frequency (RF) and heart rate (HR) increased, RMSSD and high frequency (HF) power decreased or had a tendency to decrease, while low frequency (LF) power showed no change. The BIO group responded differently in Stroop 2: while RF increased and LF power decreased, HR, RMSSD and HF power showed no change. In the BIO group, RMSSD was higher in Stroop 2 compared to Stroop 1. In conclusion, HRV biofeedback induced a short term carry-over effect during both the following rest period and laboratory-induced stress suggesting maintained HF vagal modulation in the BIO group after the intervention, and maintained LF vagal modulation in the COM group.
Relationship between cardiac autonomic function and cognitive function in Alzheimer's disease.
Nonogaki, Zen; Umegaki, Hiroyuki; Makino, Taeko; Suzuki, Yusuke; Kuzuya, Masafumi
2017-01-01
Alzheimer's disease (AD) affects many central nervous structures and neurotransmitter systems. These changes affect not only cognitive function, but also cardiac autonomic function. However, the functional relationship between cardiac autonomic function and cognition in AD has not yet been investigated. The objective of the present study was to evaluate the association between cardiac autonomic function measured by heart rate variability and cognitive function in AD. A total of 78 AD patients were recruited for this study. Cardiac autonomic function was evaluated using heart rate variability analysis. Multiple linear regression analysis was used to model the association between heart rate variability and cognitive function (global cognitive function, memory, executive function and processing speed), after adjustment for covariates. Global cognitive function was negatively associated with sympathetic modulation (low-to-high frequency power ratio). Memory performance was positively associated with parasympathetic modulation (high frequency power) and negatively associated with sympathetic modulation (low-to-high frequency power ratio). These associations were independent of age, sex, educational years, diabetes, hypertension and cholinesterase inhibitor use. Cognitive function, especially in the areas of memory, is associated with cardiac autonomic function in AD. Specifically, lower cognitive performance was found to be associated with significantly higher cardiac sympathetic and lower parasympathetic function in AD. Geriatr Gerontol Int 2017; 17: 92-98. © 2015 Japan Geriatrics Society.
Weston, Kassia S; Sacre, Julian W; Jellis, Christine L; Coombes, Jeff S
2013-01-01
The purpose of this study was to compare the presence and severity of autonomic dysfunction in type 2 diabetes mellitus patients, with and without exaggerated blood pressure responses to exercise. We performed a cross-sectional analysis of 98 patients with type 2 diabetes mellitus (aged 59±9). Both time (standard deviation of RR intervals, root-mean-square of successive RR interval differences) and frequency (total spectral power, high frequency, low frequency, very low frequency) domains of heart rate variability were analysed in a 5 min recording at rest and 20 min after a maximal treadmill test. An exaggerated blood pressure response to exercise was identified by peak blood pressure ≥190/105 mmHg (women) or ≥210/105 mmHg (men). Each group of either exaggerated exercise blood pressure response or normal blood pressure response consisted of 49 patients. At rest there were no significant differences between groups for all time and frequency domain parameters of heart rate variability. Post-exercise, there was a significant (p<0.05) reduction in the SDNN, RMSSD and TP in the exaggerated exercise blood pressure group. Independent correlates (p<0.01) of exercise systolic blood pressure included post-exercise TP, resting systolic blood pressure, cardiac autonomic neuropathy and beta-blockers (beta=-0.28, adj. R² = 0.32, p<0.001). Reduced post-exercise heart rate variability in patients with type 2 diabetes mellitus, with an exaggerated exercise blood pressure response suggests preclinical autonomic dysfunction characterized by impaired vagal modulation. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Zarei, Ali Asghar; Foroutan, Seyyed Abbas; Foroutan, Seyyed Mohsen; Erfanian Omidvar, Abbas
2011-01-01
Pyridostigmine bromide (PB) is a reversible cholinesterase inhibitor. The aim of this study was to determine the effect of orally administration of single dose sustained-released tablet of pyridostigmine bromide (PBSR) on the frequency domain indices of heart rate variability (HRV). Thirty-two healthy young men were participated in this study. They were divided into 2 groups; the pyridostigmine group (n = 22) and the placebo group (n = 10). Electrocardiogram (ECG) was recorded at 10, 30, 60, 90, 120, 150, 180, 210, 240, 300 and 420 min after PBSR administration. At each time, simultaneously, a blood sample was prepared and PB plasma concentration was measured by high-performance liquid chromatography (HPLC) method. Statistical analysis showed that in different indices of HRV, there is a significant increase in low frequency (LF) band at 300 min, but no difference in high frequency band (HF). It also showed significant decreases in normalized high frequency band (Hfnu), normalized low frequency band (Lfnu) and LF/HF ratio at 120, 240 and 300 min after PBSR administration. Maximum plasma concentration of PB was 150 min after the administration. In conclusion, administration of a single dose PBSR can enhance the frequency domains indices of HRV and improvesympathovagal balance.
Fine structure of the low-frequency spectra of heart rate and blood pressure
Kuusela, Tom A; Kaila, Timo J; Kähönen, Mika
2003-01-01
Background The aim of this study was to explore the principal frequency components of the heart rate and blood pressure variability in the low frequency (LF) and very low frequency (VLF) band. The spectral composition of the R–R interval (RRI) and systolic arterial blood pressure (SAP) in the frequency range below 0.15 Hz were carefully analyzed using three different spectral methods: Fast Fourier transform (FFT), Wigner-Ville distribution (WVD), and autoregression (AR). All spectral methods were used to create time–frequency plots to uncover the principal spectral components that are least dependent on time. The accurate frequencies of these components were calculated from the pole decomposition of the AR spectral density after determining the optimal model order – the most crucial factor when using this method – with the help of FFT and WVD methods. Results Spectral analysis of the RRI and SAP of 12 healthy subjects revealed that there are always at least three spectral components below 0.15 Hz. The three principal frequency components are 0.026 ± 0.003 (mean ± SD) Hz, 0.076 ± 0.012 Hz, and 0.117 ± 0.016 Hz. These principal components vary only slightly over time. FFT-based coherence and phase-function analysis suggests that the second and third components are related to the baroreflex control of blood pressure, since the phase difference between SAP and RRI was negative and almost constant, whereas the origin of the first component is different since no clear SAP–RRI phase relationship was found. Conclusion The above data indicate that spontaneous fluctuations in heart rate and blood pressure within the standard low-frequency range of 0.04–0.15 Hz typically occur at two frequency components rather than only at one as widely believed, and these components are not harmonically related. This new observation in humans can help explain divergent results in the literature concerning spontaneous low-frequency oscillations. It also raises methodological and computational questions regarding the usability and validity of the low-frequency spectral band when estimating sympathetic activity and baroreflex gain. PMID:14552660
Fine structure of the low-frequency spectra of heart rate and blood pressure.
Kuusela, Tom A; Kaila, Timo J; Kähönen, Mika
2003-10-13
The aim of this study was to explore the principal frequency components of the heart rate and blood pressure variability in the low frequency (LF) and very low frequency (VLF) band. The spectral composition of the R-R interval (RRI) and systolic arterial blood pressure (SAP) in the frequency range below 0.15 Hz were carefully analyzed using three different spectral methods: Fast Fourier transform (FFT), Wigner-Ville distribution (WVD), and autoregression (AR). All spectral methods were used to create time-frequency plots to uncover the principal spectral components that are least dependent on time. The accurate frequencies of these components were calculated from the pole decomposition of the AR spectral density after determining the optimal model order--the most crucial factor when using this method--with the help of FFT and WVD methods. Spectral analysis of the RRI and SAP of 12 healthy subjects revealed that there are always at least three spectral components below 0.15 Hz. The three principal frequency components are 0.026 +/- 0.003 (mean +/- SD) Hz, 0.076 +/- 0.012 Hz, and 0.117 +/- 0.016 Hz. These principal components vary only slightly over time. FFT-based coherence and phase-function analysis suggests that the second and third components are related to the baroreflex control of blood pressure, since the phase difference between SAP and RRI was negative and almost constant, whereas the origin of the first component is different since no clear SAP-RRI phase relationship was found. The above data indicate that spontaneous fluctuations in heart rate and blood pressure within the standard low-frequency range of 0.04-0.15 Hz typically occur at two frequency components rather than only at one as widely believed, and these components are not harmonically related. This new observation in humans can help explain divergent results in the literature concerning spontaneous low-frequency oscillations. It also raises methodological and computational questions regarding the usability and validity of the low-frequency spectral band when estimating sympathetic activity and baroreflex gain.
Leliveld, Lisette M C; Düpjan, Sandra; Tuchscherer, Armin; Puppe, Birger
2016-04-01
In the study of animal emotions, emotional valence has been found to be difficult to measure. Many studies of farm animals' emotions have therefore focussed on the identification of indicators of strong, mainly negative, emotions. However, subtle variations in emotional valence, such as those caused by rather moderate differences in husbandry conditions, may also affect animals' mood and welfare when such variations occur consistently. In this study, we investigated whether repeated moderate aversive or rewarding events could lead to measurable differences in emotional valence in young, weaned pigs. We conditioned 105 female pigs in a test arena to either a repeated startling procedure (sudden noises or appearances of objects) or a repeated rewarding procedure (applesauce, toy and straw) over 11 sessions. Control pigs were also regularly exposed to the same test arena but without conditioning. Before and after conditioning, we measured heart rate and its variability as well as the behavioural reactions of the subjects in the test arena, with a special focus on detailed acoustic analyses of their vocalisations. The behavioural and heart rate measures were analysed as changes compared to the baseline values before conditioning. A limited number of the putative indicators of emotional valence were affected by the conditioning. We found that the negatively conditioned pigs showed changes that were significantly different from those in control pigs, namely a decrease in locomotion and an increase in standing. The positively conditioned pigs, however, showed a stronger increase in heart rate and a smaller decrease in SDNN (a heart rate variability parameter indicating changes in autonomic regulation) compared to the controls. Compared to the negatively conditioned pigs, the positively conditioned pigs produced fewer vocalisations overall as well as fewer low-frequency grunts but more high-frequency grunts. The low-frequency grunts of the negatively conditioned pigs also showed lower frequency parameters (bandwidth, maximum frequency, 25% and 50% quartiles) compared to those of the positively conditioned pigs. In any of the statistically significant results, the conditioning accounted for 1.5-11.9% of variability in the outcome variable. Hence, we conclude that repeated moderate aversive and rewarding events have weak but measurable effects on some aspects of behaviour and physiology in young pigs, possibly indicating changes in emotional valence, which could ultimately affect their welfare. The combination of ethophysiological indicators, i.e., the concurrent examination of heart rate measures, behavioural responses and especially vocalisation patterns, as used in the current study, might be a useful way of examining subtle effects on emotional valence in further studies. Copyright © 2016 Elsevier Inc. All rights reserved.
The effects of auditory stimulation with music on heart rate variability in healthy women.
Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de
2013-07-01
There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level.
The effects of auditory stimulation with music on heart rate variability in healthy women
Roque, Adriano L.; Valenti, Vitor E.; Guida, Heraldo L.; Campos, Mônica F.; Knap, André; Vanderlei, Luiz Carlos M.; Ferreira, Lucas L.; Ferreira, Celso; de Abreu, Luiz Carlos
2013-01-01
OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. CONCLUSION: We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level. PMID:23917660
Kassamali, Rahil H; Kim, Daniel H; Patel, Hiten; Raichura, Nitin; Hoey, Edward T D; Hodson, James; Hussain, Shahid
2014-10-01
The purpose of this study was to assess the safety of heart rate optimization by use of β-adrenergic blockade solely by the i.v. route before coronary CT angiography. The records of 679 patients undergoing CT coronary angiography after receiving i.v. β-adrenergic blockade were retrospectively analyzed. Health screening was completed before scanning, and heart rate was optimized by administration of i.v. metoprolol titrated to a maximum of 70 mg to achieve a heart rate less than 65 beats/min. The median i.v. dose was 20 mg (range, 5-70 mg). The 679 patients analyzed had a total of 10 complications (1.47%). Major complications, defined as not resolving with observation and analgesia alone, occurred in only three patients (0.44%). These complications included a second-degree atrioventricular block. A total of 299 patients (44.0%) needed more than 20 mg of i.v. metoprolol to achieve target heart rate. Only three patients needed the maximum i.v. dose of 70 mg metoprolol. Target heart rate was reached successfully in 666 patients (98.1%) with doses of less than 70 mg. This study did not show a statistically significant association between increasing complication frequency and increasing dose. This study showed that high doses of i.v. metoprolol can be used effectively and with a low rate of major complications to control heart rate before coronary CT angiography in correctly screened patients.
Verdurmen, Kim M J; Warmerdam, Guy J J; Lempersz, Carlijn; Hulsenboom, Alexandra D J; Renckens, Joris; Dieleman, Jeanne P; Vullings, Rik; van Laar, Judith O E H; Oei, S Guid
2018-04-01
Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm labour. Fetal heart rate variability is one of the most important parameters to assess in fetal monitoring, since it is a reliable indicator for fetal distress. To describe the effect of betamethasone on fetal heart rate variability, by applying spectral analysis on non-invasive fetal electrocardiogram recordings. Prospective cohort study. Patients that require betamethasone, with a gestational age from 24 weeks onwards. Fetal heart rate variability parameters on day 1, 2, and 3 after betamethasone administration are compared to a reference measurement. Following 68 inclusions, 12 patients remained with complete series of measurements and sufficient data quality. During day 1, an increase in absolute fetal heart rate variability values was seen. During day 2, a decrease in these values was seen. All trends indicate to return to pre-medication values on day 3. Normalised high- and low-frequency power show little changes during the study period. The changes in fetal heart rate variability following betamethasone administration show the same pattern when calculated by spectral analysis of the fetal electrocardiogram, as when calculated by cardiotocography. Since normalised spectral values show little changes, the influence of autonomic modulation seems minor. Copyright © 2018 Elsevier B.V. All rights reserved.
Changes in heart rate associated with contest outcome in agonistic encounters in lobsters.
Hernáindez-Falcón, Jesús; Basu, Alo C; Govindasamy, Siddhartan; Kravitz, Edward A
2005-03-01
Agonistic contests between lobsters housed together in a confined space progress through encounters of increasing intensity until a dominance relationship is established. Once this relationship is established, losing animals continually retreat from the advances of winners. These encounters are likely to consume much energy in both winning and losing animals. Therefore, one might expect involvement of many physiological systems before, during and after fights. Here, we report effects of agonistic encounters on cardiac frequency in winning and losing adult lobsters involved in dyadic interactions. The results show that: (i) small but significant increases in heart rate are observed upon chemical detection of a conspecific; (ii) during agonistic interactions, further increases in heart rate are seen; and (iii) ultimate winners exhibit greater increases in heart rate lasting longer periods of time compared to ultimate losers. Heart rate in winners remains elevated for at least 15 min after the contests have ended and animals have been returned to their home tanks. Reduced effects are seen in second and third pairings between familiar opponents. The sustained changes in heart rate that we observe in winning lobsters may result from hormonal modulation of cardiac function related to the change in social status brought about by contest outcome.
Heart rate detection from an electronic weighing scale.
González-Landaeta, R; Casas, O; Pallàs-Areny, R
2007-01-01
We propose a novel technique for heart rate detection on a subject that stands on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear, and does not require any sensors attached to the body. We have applied our method to three different weighing scales, and estimated whether their sensitivity and frequency response suited heart rate detection. Scale sensitivities were from 490 nV/V/N to 1670 nV/V/N, all had an underdamped transient response and their dynamic gain error was below 19% at 10 Hz, which are acceptable values for heart rate estimation. We also designed a pulse detection system based on off-the-shelf integrated circuits, whose gain was about 70x10(3) and able to sense force variations about 240 mN. The signal-to-noise ratio (SNR) of the main peaks of the pulse signal detected was higher than 48 dB, which is large enough to estimate the heart rate by simple signal processing methods. To validate the method, the ECG and the force signal were simultaneously recorded on 12 volunteers. The maximal error obtained from heart rates determined from these two signals was +/-0.6 beats/minute.
Do former preterm infants remember and respond to neonatal intensive care unit noise?
Barreto, Edwin D; Morris, Brenda H; Philbin, M Kathleen; Gray, Lincoln C; Lasky, Robert E
2006-11-01
Previous studies have shown that 4-month-old infants have a decrease in heart rate, a component of the orienting reflex, in response to interesting auditory stimuli and an increase in heart rate to aversive auditory stimuli. To compare the heart rate responses of former preterm and term infants at 4-5 months corrected age to a recording of NICU noises. 13 former preterm infants and 17 full-term infants were presented NICU noise and another noise of similar level and frequency content in random order. Heart rate 10s prior to the stimulus and for 20s during the stimulus was analyzed. Group differences in second by second heart rate changes in response to the two noise stimuli were compared by analysis of covariance. Both the preterm and term newborns responded similarly to the NICU noise and the control noise. The preterm infants did not alter their heart rate in response to either stimulus. In contrast, the term infants displayed an orienting response to the second stimulus presented regardless of whether it was the NICU or control noise. Former preterm infants at 4-5 months corrected age have reduced responsiveness to auditory stimulation in comparison to 4- to 5-month-old term infants. Furthermore, they did not respond to the NICU noise as an aversive stimulus.
Counotte, Jacqueline; Pot-Kolder, Roos; van Roon, Arie M; Hoskam, Olivier; van der Gaag, Mark; Veling, Wim
2017-06-01
Social stressors are associated with an increased risk of psychosis. Stress sensitisation is thought to be an underlying mechanism and may be reflected in an altered autonomic stress response. Using an experimental Virtual Reality design, the autonomic stress response to social stressors was examined in participants with different liability to psychosis. Fifty-five patients with recent onset psychotic disorder, 20 patients at ultra-high risk for psychosis, 42 siblings of patients with psychosis and 53 controls were exposed to social stressors (crowdedness, ethnic minority status and hostility) in a Virtual Reality environment. Heart rate variability parameters and skin conductance levels were measured at baseline and during Virtual Reality experiments. High psychosis liability groups had significantly increased heart rate and decreased heart rate variability compared to low liability groups both at baseline and during Virtual Reality experiments. Both low frequency (LF) and high frequency (HF) power were reduced, while the LF/HF ratio was similar between groups. The number of virtual social stressors significantly affected heart rate, HF, LF/HF and skin conductance level. There was no interaction between psychosis liability and amount of virtual social stress. High liability to psychosis is associated with decreased parasympathetic activity in virtual social environments, which reflects generally high levels of arousal, rather than increased autonomic reactivity to social stressors. Copyright © 2016 Elsevier B.V. All rights reserved.
Nocturnal snoring decreases daytime baroreceptor sensitivity.
Schöbel, Christoph; Fietze, Ingo; Glos, Martin; Schary, Inett; Blau, Alexander; Baumann, Gert; Penzel, Thomas
2014-07-01
In patients with obstructive sleep apnea heart rate variability and baroreceptor sensitivity during night and daytime are impaired. Snoring without obstructive sleep apnea may already influence heart rate variability and baroreceptor sensitivity during daytime. Cardiovascular daytime testing was performed in 11 snorers and age, BMI, and gender matched controls. Sleep apnea and snoring were quantified by sleep recordings. Paced breathing was performed during daytime with ECG, non-invasive blood pressure, and respiration recorded. Heart rate variability and blood pressure variability were analyzed in the time and frequency domain. Baroreceptor sensitivity (alpha gain) was calculated. In snorers a significant increase in high frequency systolic blood pressure variability (SBPV-HF) compared to control group (0.37 mm Hg(2) vs. 0.11 mm Hg(2) for 12 breaths and 0.35 mm Hg(2) vs. 0.10 mm Hg(2) for 15 breaths) was demonstrated. Furthermore a lower baroreceptor sensitivity was found in snorers compared to controls (9.2 ms/mm Hg vs. 16.2 ms/mm Hg for 12 breaths and 8.5 ms/mm Hg vs. 17.4 ms/mm Hg for 15 breaths per minute) using the paced breathing protocol. Mean heart rate was elevated in snorers as well. Snorers may have a reduced parasympathetic tone during daytime rather than an increased sympathetic tone. Copyright © 2014 Elsevier Ltd. All rights reserved.
Baik-Schneditz, Nariae; Urlesberger, Berndt; Schwaberger, Bernhard; Mileder, Lukas; Schmölzer, Georg; Avian, Alexander; Pichler, Gerhard
2018-06-01
This study analysed tactile stimulation during neonatal transition and resuscitation in preterm and term neonates born by Caesarean delivery. It examined the frequency, location and body region, duration and possible effects of stimulation on heart rate and arterial oxygen saturation (SpO 2 ). Two independent investigators analysed video recordings of tactile stimulation on term and preterm neonates during neonatal transition from January 2012 to December 2014. They were recorded during a prospective observational study and randomised controlled trial at a tertiary centre, the Medical University of Graz, Austria. SpO 2 and heart rate were continuously recorded. Data on the frequency, body region and duration of stimulation were collected. To investigate the possible effects of stimulation, SpO 2 and heart rate were compared before and after stimulation. Term infants received tactile stimulation more than once, and it tended to start later, last longer and be applied in more locations than in preterm infants. Only preterm infants showed a significant increase in SpO 2 after stimulation and heart rates did not show any significant changes in either group. Tactile stimulation was applied in different ways to preterm and term infants during neonatal transition and SpO 2 showed a significant increase in preterm infants. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
The Effect of Sex on Heart Rate Variability at High Altitude.
Boos, Christopher John; Vincent, Emma; Mellor, Adrian; O'Hara, John; Newman, Caroline; Cruttenden, Richard; Scott, Phylip; Cooke, Mark; Matu, Jamie; Woods, David Richard
2017-12-01
There is evidence suggesting that high altitude (HA) exposure leads to a fall in heart rate variability (HRV) that is linked to the development of acute mountain sickness (AMS). The effects of sex on changes in HRV at HA and its relationship to AMS are unknown. HRV (5-min single-lead ECG) was measured in 63 healthy adults (41 men and 22 women) 18-56 yr of age at sea level (SL) and during a HA trek at 3619, 4600, and 5140 m, respectively. The main effects of altitude (SL, 3619 m, 4600 m, and 5140 m) and sex (men vs women) and their potential interaction were assessed using a factorial repeated-measures ANOVA. Logistic regression analyses were performed to assess the ability of HRV to predict AMS. Men and women were of similar age (31.2 ± 9.3 vs 31.7 ± 7.5 yr), ethnicity, and body and mass index. There was main effect for altitude on heart rate, SD of normal-to-normal (NN) intervals (SDNN), root mean square of successive differences (RMSSD), number of pairs of successive NN differing by >50 ms (NN50), NN50/total number of NN, very low-frequency power, low-frequency (LF) power, high-frequency (HF) power, and total power (TP). The most consistent effect on post hoc analysis was reduction in these HRV measures between 3619 and 5140 m at HA. Heart rate was significantly lower and SDNN, RMSSD, LF power, HF power, and TP were higher in men compared with women at HA. There was no interaction between sex and altitude for any of the HRV indices measured. HRV was not predictive of AMS development. Increasing HA leads to a reduction in HRV. Significant differences between men and women emerge at HA. HRV was not predictive of AMS.
Effect of Different Phases of Menstrual Cycle on Heart Rate Variability (HRV).
Brar, Tejinder Kaur; Singh, K D; Kumar, Avnish
2015-10-01
Heart Rate Variability (HRV), which is a measure of the cardiac autonomic tone, displays physiological changes throughout the menstrual cycle. The functions of the ANS in various phases of the menstrual cycle were examined in some studies. The aim of our study was to observe the effect of menstrual cycle on cardiac autonomic function parameters in healthy females. A cross-sectional (observational) study was conducted on 50 healthy females, in the age group of 18-25 years. Heart Rate Variability (HRV) was recorded by Physio Pac (PC-2004). The data consisted of Time Domain Analysis and Frequency Domain Analysis in menstrual, proliferative and secretory phase of menstrual cycle. Data collected was analysed statistically using student's pair t-test. The difference in mean heart rate, LF power%, LFnu and HFnu in menstrual and proliferative phase was found to be statistically significant. The difference in mean RR, Mean HR, RMSSD (the square root of the mean of the squares of the successive differences between adjacent NNs.), NN50 (the number of pairs of successive NNs that differ by more than 50 ms), pNN50 (the proportion of NN50 divided by total number of NNs.), VLF (very low frequency) power, LF (low frequency) power, LF power%, HF power %, LF/HF ratio, LFnu and HFnu was found to be statistically significant in proliferative and secretory phase. The difference in Mean RR, Mean HR, LFnu and HFnu was found to be statistically significant in secretory and menstrual phases. From the study it can be concluded that sympathetic nervous activity in secretory phase is greater than in the proliferative phase, whereas parasympathetic nervous activity is predominant in proliferative phase.
Effect of Different Phases of Menstrual Cycle on Heart Rate Variability (HRV)
Singh, K. D.; Kumar, Avnish
2015-01-01
Background Heart Rate Variability (HRV), which is a measure of the cardiac autonomic tone, displays physiological changes throughout the menstrual cycle. The functions of the ANS in various phases of the menstrual cycle were examined in some studies. Aims and Objectives The aim of our study was to observe the effect of menstrual cycle on cardiac autonomic function parameters in healthy females. Materials and Methods A cross-sectional (observational) study was conducted on 50 healthy females, in the age group of 18-25 years. Heart Rate Variability (HRV) was recorded by Physio Pac (PC-2004). The data consisted of Time Domain Analysis and Frequency Domain Analysis in menstrual, proliferative and secretory phase of menstrual cycle. Data collected was analysed statistically using student’s pair t-test. Results The difference in mean heart rate, LF power%, LFnu and HFnu in menstrual and proliferative phase was found to be statistically significant. The difference in mean RR, Mean HR, RMSSD (the square root of the mean of the squares of the successive differences between adjacent NNs.), NN50 (the number of pairs of successive NNs that differ by more than 50 ms), pNN50 (the proportion of NN50 divided by total number of NNs.), VLF (very low frequency) power, LF (low frequency) power, LF power%, HF power %, LF/HF ratio, LFnu and HFnu was found to be statistically significant in proliferative and secretory phase. The difference in Mean RR, Mean HR, LFnu and HFnu was found to be statistically significant in secretory and menstrual phases. Conclusion From the study it can be concluded that sympathetic nervous activity in secretory phase is greater than in the proliferative phase, whereas parasympathetic nervous activity is predominant in proliferative phase. PMID:26557512
Heart rate variability in newborns.
Javorka, K; Lehotska, Z; Kozar, M; Uhrikova, Z; Kolarovszki, B; Javorka, M; Zibolen, M
2017-09-22
Heart rate (HR) and heart rate variability (HRV) in newborns is influenced by genetic determinants, gestational and postnatal age, and other variables. Premature infants have a reduced HRV. In neonatal HRV evaluated by spectral analysis, a dominant activity can be found in low frequency (LF) band (combined parasympathetic and sympathetic component). During the first postnatal days the activity in the high frequency (HF) band (parasympathetic component) rises, together with an increase in LF band and total HRV. Hypotrophy in newborn can cause less mature autonomic cardiac control with a higher contribution of sympathetic activity to HRV as demonstrated by sequence plot analysis. During quiet sleep (QS) in newborns HF oscillations increase - a phenomenon less expressed or missing in premature infants. In active sleep (AS), HRV is enhanced in contrast to reduced activity in HF band due to the rise of spectral activity in LF band. Comparison of the HR and HRV in newborns born by physiological vaginal delivery, without (VD) and with epidural anesthesia (EDA) and via sectio cesarea (SC) showed no significant differences in HR and in HRV time domain parameters. Analysis in the frequency domain revealed, that the lowest sympathetic activity in chronotropic cardiac chronotropic regulation is in the VD group. Different neonatal pathological states can be associated with a reduction of HRV and an improvement in the health conditions is followed by changes in HRV what can be use as a possible prognostic marker. Examination of heart rate variability in neonatology can provide information on the maturity of the cardiac chronotropic regulation in early postnatal life, on postnatal adaptation and in pathological conditions about the potential dysregulation of cardiac function in newborns, especially in preterm infants.
Chen, Jin-Long; Chiu, Hung-Wen; Tseng, Yin-Jiun; Chu, Woei-Chyn
2006-06-01
The clinical manifestations of hyperthyroidism resemble those of the hyperadrenergic state. This study was designed to evaluate the impact of hyperthyroidism on the autonomic nervous system (ANS) and to investigate the relationship between serum thyroid hormone concentrations and parameters of spectral heart rate variability (HRV) analysis in hyperthyroidism. Thirty-two hyperthyroid Graves' disease patients (mean age 31 years) and 32 sex-, age-, and body mass index (BMI)-matched normal control subjects were recruited to receive one-channel electrocardiogram (ECG) recording. The cardiac autonomic nervous function was evaluated by the spectral analysis of HRV, which indicates the autonomic modulation of the sinus node. The correlation coefficients between serum thyroid hormone concentrations and parameters of the spectral HRV analysis were also computed. The hyperthyroid patients revealed significant differences (P < 0.001) compared with the controls in the following HRV parameters: a decrease in total power (TP), very low frequency power (VLF), low frequency power (LF), high frequency power (HF), and HF in normalized units (HF%); and an increase in LF in normalized units (LF%) and in the ratio of LF to HF (LF/HF). After correction of hyperthyroidism in 28 patients, all of the above parameters were restored to levels comparable to those of the controls. In addition, serum thyroid hormone concentrations showed significant correlations with spectral HRV parameters. Hyperthyroidism is in a sympathovagal imbalanced state, characterized by both increased sympathetic and decreased vagal modulation of the heart rate. These autonomic dysfunctions can be detected simultaneously by spectral analysis of HRV, and the spectral HRV parameters could reflect the disease severity in hyperthyroid patients.
Bernardi, L; Wdowczyk-Szulc, J; Valenti, C; Castoldi, S; Passino, C; Spadacini, G; Sleight, P
2000-05-01
To assess whether talking or reading (silently or aloud) could affect heart rate variability (HRV) and to what extent these changes require a simultaneous recording of respiratory activity to be correctly interpreted. Sympathetic predominance in the power spectrum obtained from short- and long-term HRV recordings predicts a poor prognosis in a number of cardiac diseases. Heart rate variability is often recorded without measuring respiration; slow breaths might artefactually increase low frequency power in RR interval (RR) and falsely mimic sympathetic activation. In 12 healthy volunteers we evaluated the effect of free talking and reading, silently and aloud, on respiration, RR and blood pressure (BP). We also compared spontaneous breathing to controlled breathing and mental arithmetic, silent or aloud. The power in the so called low- (LF) and high-frequency (HF) bands in RR and BP was obtained from autoregressive power spectrum analysis. Compared with spontaneous breathing, reading silently increased the speed of breathing (p < 0.05), decreased mean RR and RR variability and increased BP. Reading aloud, free talking and mental arithmetic aloud shifted the respiratory frequency into the LF band, thus increasing LF% and decreasing HF% to a similar degree in both RR and respiration, with decrease in mean RR but with minor differences in crude RR variability. Simple mental and verbal activities markedly affect HRV through changes in respiratory frequency. This possibility should be taken into account when analyzing HRV without simultaneous acquisition and analysis of respiration.
Effects of moderate and heavy endurance exercise on nocturnal HRV.
Hynynen, E; Vesterinen, V; Rusko, H; Nummela, A
2010-06-01
This study examined the effects of endurance exercise on nocturnal autonomic modulation. Nocturnal R-R intervals were collected after a rest day, after a moderate endurance exercise and after a marathon run in ten healthy, physically active men. Heart rate variability (HRV) was analyzed as a continuous four-hour period starting 30 min after going to bed for sleep. In relation to average nocturnal heart rate after rest day, increases to 109+/-6% and 130+/-11% of baseline were found after moderate endurance exercise and marathon, respectively. Standard deviation of R-R intervals decreased to 90+/-9% and 64+/-10%, root-mean-square of differences between adjacent R-R intervals to 87+/-10% and 55+/-16%, and high frequency power to 77+/-19% and 34+/-19% of baseline after moderate endurance exercise and marathon, respectively. Also nocturnal low frequency power decreased to 56+/-26% of baseline after the marathon. Changes in nocturnal heart rate and HRV suggest prolonged dose-response effects on autonomic modulation after exercises, which may give useful information on the extent of exercise-induced nocturnal autonomic modulation and disturbance to the homeostasis.
SEX DIFFERENCES IN THE EFFECTS OF DIVERSE SOUNDS ON HEART RATE VARIABILITY.
Nozaki, Haruka; Uetake, Teruo; Shimoda, Masahiro
2015-12-01
With the goal of facilitating the creation of relaxing sound environments in stressful places, such as offices, we examined differences in the heart rate fluctuations of men and women induced by different sounds. Twenty-three healthy students (13 males and 10 females) aged between 18 and 23 listened to seven different sounds while we collected electrocardiogram data. We extracted the high frequency component (HF) and low frequency component (LF) of the signals using the wavelet method, and calculated LF/HF. We found no statistically significant differences between males and females in the frequency distribution of a no change group, increased group, and decreased group for any sound. However, certain sounds had somewhat similar patterns for men and women for all three groups. Additionally, the pairs of experimental sounds with highly similar effects on individuals were different for men and women.
Sibir'ianov, A R; Sergeeva, N V; Podzolko, T Iu
2013-01-01
The present study was designed to study the influence of classical back and neck massage on the functional state of the cardiovascular system and its regulation under conditions of short-term physical loading in the healthy adolescents. It was shown that a course of classical massage promoted the reduction of arterial pressure in all children and the heart rate frequency in the boys. This effect was apparent as a reaction of blood circulation to the dosed physical exercises manifested as a rise in the heart rate frequency and stroke volume. The effects of classical massage were shown to be mediated through the alteration of the levels and mechanisms of regulation of the blood circulatory system and the enhancement of humoral and metabolic segmental sympathetic influences associated with the adaptation to the impact of massage therapy.
Commercialization and Industrial Development for the Fetal Hear Rate Monitor
NASA Technical Reports Server (NTRS)
Zahorian, Stephen
2000-01-01
The primary objectives for this task were to continue the development and testing of the NASA/ODU passive acoustic fetal heart rate monitor, with the goal of transferring the technology to the commercial sector. Areas of work included: 1. To assist in the development of a new hardware front end electronics box for the fetal heart rate monitor, so as to reduce the size of the electronics box, and also to provide for a "low-frequency" and "high-frequency" mode of operation. To make necessary changes in the operating software to support the two modes of operation. 2. To provide an option for a strip chart recording for the system, so that medical personnel could more easily make comparisons with ultra sound strip chart recordings. and 3. To help with continued testing of the system.
The heart field effect: Synchronization of healer-subject heart rates in energy therapy.
Bair, Christine Caldwell
2008-01-01
Recent health research has focused on subtle energy and vibrational frequency as key components of health and healing. In particular, intentional direction of bioenergy is receiving increasing scientific attention. This study investigates the effect of the healer's electromagnetic (EM) heart field upon subjects during energy healing as measured by synchronization of heart rates and scores on a Subjective Units of Distress (SUD) scale and a Profile of Mood States (POMS) inventory. A nonequivalent pretest-posttest design was used based on heart rate comparisons between healer and subject and correlated with pre-and posttest SUD and POMS scores. Subjects included those who sat within the 3- to 4-foot "strong" range of the independent variable, the healer's heart field, while performing self-application of WHEE (the wholistic hybrid derived from EMDR [eye movement desensitization and reprocessing], and EFT [emotional freedom technique]), a meridian-based tapping technique (n=50); and those who performed the same process beyond the 15- to 18-foot range of the healer's EM heart field (n=41). The dependent variables were heart rate, SUD, and POMS inventory. All subjects completed these measures within 1 hour. Study results showed statistically significant heart-rate synchronization with the intervention population. In addition, SUD and POMS scores demonstrated considerably more improvement than in the control population, indicating additional benefit beyond the meridian-based therapies, such as WHEE, alone. Additional findings and future research recommendations are presented in this article.
Non stationary analysis of heart rate variability during the obstructive sleep apnea.
Méndez, M O; Bianchi, A M; Cerutti, S
2004-01-01
Characteristic fluctuations of the heart rate are found during obstructive sleep apnea (OSA), bradycardia in apneonic phase and tachycardia at the recovery of ventilation. In order to assess its autonomic response, in this study, the time-frequency distribution of Born-Jordan and evolutive Poincare plots are used. From Physionet was taken a database with records of ECG and respiratory signals. During the OSA all spectral indexes presented oscillations correspondent to the changes between brady and tachycardia of the RR intervals as well as greater values than during control epochs. Born-Jordan distribution and evolutive Poincare plots could help to characterize and develop an index for the evaluation of OSA. Very low frequency could also be a good index of OSA.
Lenoir, Augustin; Trachsel, Dagmar S; Younes, Mohamed; Barrey, Eric; Robert, Céline
2017-01-01
Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland-Altman analysis and the Lin's coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, root mean square of successive differences, SD1, SD2, low frequency, high frequency), the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device.
Augmented baroreflex heart rate gain after moderate-intensity, dynamic exercise
NASA Technical Reports Server (NTRS)
Halliwill, J. R.; Taylor, J. A.; Hartwig, T. D.; Eckberg, D. L.
1996-01-01
The occurrence of a sustained vasodilation and hypotension after acute, dynamic exercise suggests that exercise may alter arterial baroreflex mechanisms. Therefore, we assessed systemic hemodynamics, baroreflex regulation of heart rate, and cardiac vagal tone after 60 min of cycling at 60% peak oxygen consumption in 12 healthy, untrained men and women (ages 21-28 yr). We derived sigmoidal carotid-cardiac baroreflex relations by measurement of R-R interval changes induced by ramped, stepwise, R-wave-triggered changes in external neck pressure from 40 to -65 mmHg. We estimated tonic cardiac vagal control with power spectral analysis of R-R interval variability in the respiratory frequency band (0.2-0.3 Hz) during frequency- and tidal volume-controlled breathing. Both mean arterial pressure and total peripheral resistance were reduced postexercise [pressure: from 86 +/- 2 (mean +/- SE) to 81 +/- 2 mmHg; resistance: from 23 +/- 2 to 16 +/- 1 units; both P < 0.05]. Cardiac output was increased postexercise (from 3.9 +/- 0.3 to 5.5 +/- 0.5 l/min, P < 0.05). Both slope and range of the carotid-cardiac baroreflex relation were increased postexercise (slope: from 4.7 +/- 0.7 to 6.1 +/- 0.9 ms/mmHg; range: from 186 +/- 23 to 238 +/- 30 ms, P < 0.05). Respiratory R-R interval variability (cardiac vagal tone) was not changed at any time after exercise, whereas heart rate and plasma norepinephrine levels were elevated. Thus moderate-intensity, dynamic exercise increases heart rate and cardiac output, reduces peripheral vascular resistance, and augments baroreflex responsiveness. Our data suggest that augmented baroreflex heart rate gain restrains rather than contributes to postexercise hypotension, which appears to be mediated predominately by vasodilation.
NASA Technical Reports Server (NTRS)
Evans, J. M.; Ziegler, M. G.; Patwardhan, A. R.; Ott, J. B.; Kim, C. S.; Leonelli, F. M.; Knapp, C. F.
2001-01-01
The autonomic nervous system drives variability in heart rate, vascular tone, cardiac ejection, and arterial pressure, but gender differences in autonomic regulation of the latter three parameters are not well documented. In addition to mean values, we used spectral analysis to calculate variability in arterial pressure, heart rate (R-R interval, RRI), stroke volume, and total peripheral resistance (TPR) and measured circulating levels of catecholamines and pancreatic polypeptide in two groups of 25 +/- 1.2-yr-old, healthy men and healthy follicular-phase women (40 total subjects, 10 men and 10 women per group). Group 1 subjects were studied supine, before and after beta- and muscarinic autonomic blockades, administered singly and together on separate days of study. Group 2 subjects were studied supine and drug free with the additional measurement of skin perfusion. In the unblocked state, we found that circulating levels of epinephrine and total spectral power of stroke volume, TPR, and skin perfusion ranged from two to six times greater in men than in women. The difference (men > women) in spectral power of TPR was maintained after beta- and muscarinic blockades, suggesting that the greater oscillations of vascular resistance in men may be alpha-adrenergically mediated. Men exhibited muscarinic buffering of mean TPR whereas women exhibited beta-adrenergic buffering of mean TPR as well as TPR and heart rate oscillations. Women had a greater distribution of RRI power in the breathing frequency range and a less negative slope of ln RRI power vs. ln frequency, both indicators that parasympathetic stimuli were the dominant influence on women's heart rate variability. The results of our study suggest a predominance of sympathetic vascular regulation in men compared with a dominant parasympathetic influence on heart rate regulation in women.
An exploration of heart rate response to differing music rhythm and tempos.
da Silva, Ariany G; Guida, Heraldo L; Antônio, Ana Márcia Dos S; Marcomini, Renata S; Fontes, Anne M G G; Carlos de Abreu, Luiz; Roque, Adriano L; Silva, Sidney B; Raimundo, Rodrigo D; Ferreira, Celso; Valenti, Vitor E
2014-05-01
The aim of this study was to investigate acute cardiac response and heart rate variability (HRV) when listening to differing forms of music. Eleven healthy men aged between 18 and 25 years old were included in the study. HRV was recorded at rest for ten minutes with no music, then were asked to listen to classical baroque or heavy metal music for a period of 20 min. It was noted that heart rate variability did not affect HRV indices for time and frequency. In conclusion, music with different tempos does not influence cardiac autonomic regulation in men. However more studies are suggested to explore this topic in greater detail. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Terzi, Ayşen; Sezgin, Atilla; Tunca, Zeynep; Deniz, Ebru; Ayva, Ebru Şebnem; Haberal Reyhan, Nihan; Müderrisoğlu, Haldun; Özdemir, Binnaz Handan
2015-04-01
The purpose of this study was to investigate the frequency and prognostic importance of acute cellular rejection after heart transplant. All 84 heart transplant patients at our center from January 1993 to January 2014, including all 576 endomyocardial biopsies, were evaluated with retrospective review of clinical records and endomyocardial biopsies. Routine and clinically indicated endomyocardial biopsies after heart transplant were graded for acute cellular rejection (2005 International Society for Heart and Lung Transplantation Working Formulation). Survival analysis was performed using Kaplan-Meier method. There were 61 male (73%) and 23 female recipients. Median age at heart transplant was 29 years (range, 1-62 y). Posttransplant early mortality rate was 17.9% (15 patients). In the other 69 patients, 23 patients died and 46 patients (66.7%) were alive at mean 69.3 ± 7.2 months after heart transplant. Mean follow-up was 35.4 ± 29.8 months (range, 0.07-117.5 mo). Mean 8.4 ± 4.2 endomyocardial biopsies (range, 1-19 biopsies) were performed per patient. Median first biopsy time was 7 days (range, 1-78 d). The frequency of posttransplant acute cellular rejection was 63.8% (44 of 69 patients) by histopathology; 86% patients experienced the first episode of acute cellular rejection within 6 months after transplant. There were 18 patients with acute cellular rejection ≥ grade 2R on ≥ 1 endomyocardial biopsy in 44 patients with acute cellular rejection. No significant difference was observed between survival rates of patients with grade 1R or ≥ grade 2R acute cellular rejection, or between survival rates of patients with or without diagnosis of any grade of acute cellular rejection. Acute cellular rejection was not related to any prognostic risk factor. Acute cellular rejection had no negative effect on heart recipient long-term survival, but it was a frequent complication after heart transplant, especially within the first 6 months.
Diving bradycardia of elderly Korean women divers, haenyeo, in cold seawater: a field report
LEE, Joo-Young; LEE, Hyo-Hyun; KIM, Siyeon; JANG, Young-Joon; BAEK, Yoon-Jeong; KANG, Kwon-Yong
2015-01-01
The purpose of the present field study was to explore diving patterns and heart rate of elderly Korean women divers (haenyeo) while breath-hold diving in cold seawater. We hypothesized that the decreasing rate in heart rate of elderly haenyeos during breath-hold diving was greater and total diving time was shorter than those of young haenyeos from previous studies. Nine haenyeos participated in a field study [68 ± 10 yr in age, ranged from 56 to 83 yr] at a seawater temperature of 10 to 13 °C. Average total diving time including surface swimming time between dives was 253 ± 73 min (155–341 min). Total frequency of dives was 97 ± 28 times and they dived 23 ± 8 times per hour. All haenyeos showed diving bradycardia with a decreased rate of 20 ± 8% at the bottom time (101 ± 20 bpm) when compared to surface swimming time (125 ± 16 bpm) in the sea. Older haenyeos among the nine elderly haenyeos had shorter diving time, less diving frequencies, and lower heart rate at work (p<0.05). These reductions imply that haenyeos voluntarily adjust their workload along with advancing age and diminished cardiovascular functions. PMID:26632118
Diving bradycardia of elderly Korean women divers, haenyeo, in cold seawater: a field report.
Lee, Joo-Young; Lee, Hyo-Hyun; Kim, Siyeon; Jang, Young-Joon; Baek, Yoon-Jeong; Kang, Kwon-Yong
2016-01-01
The purpose of the present field study was to explore diving patterns and heart rate of elderly Korean women divers (haenyeo) while breath-hold diving in cold seawater. We hypothesized that the decreasing rate in heart rate of elderly haenyeos during breath-hold diving was greater and total diving time was shorter than those of young haenyeos from previous studies. Nine haenyeos participated in a field study [68 ± 10 yr in age, ranged from 56 to 83 yr] at a seawater temperature of 10 to 13 °C. Average total diving time including surface swimming time between dives was 253 ± 73 min (155-341 min). Total frequency of dives was 97 ± 28 times and they dived 23 ± 8 times per hour. All haenyeos showed diving bradycardia with a decreased rate of 20 ± 8% at the bottom time (101 ± 20 bpm) when compared to surface swimming time (125 ± 16 bpm) in the sea. Older haenyeos among the nine elderly haenyeos had shorter diving time, less diving frequencies, and lower heart rate at work (p<0.05). These reductions imply that haenyeos voluntarily adjust their workload along with advancing age and diminished cardiovascular functions.
Fortunato, John E; Tegeler, Catherine L; Gerdes, Lee; Lee, Sung W; Pajewski, Nicholas M; Franco, Meghan E; Cook, Jared F; Shaltout, Hossam A; Tegeler, Charles H
2016-03-01
Autonomic dysregulation and heterogeneous symptoms characterize postural orthostatic tachycardia syndrome (POTS). This study evaluated the effect of high-resolution, relational, resonance-based, electroencephalic mirroring (HIRREM(®)), a noninvasive, allostatic neurotechnology for relaxation and auto-calibration of neural oscillations, on heart rate variability, brain asymmetry, and autonomic symptoms, in adolescents with POTS. Seven subjects with POTS (three males, ages 15-18) underwent a median of 14 (10-16) HIRREM sessions over 13 (8-17) days. Autonomic function was assessed from 10-min continuous heart rate and blood pressure recordings, pre- and post-HIRREM. One-minute epochs of temporal high-frequency (23-36 Hz) brain electrical activity data (T3 and T4, eyes closed) were analyzed from baseline HIRREM assessment and subsequent sessions. Subjects rated autonomic symptoms before and after HIRREM. Four of seven were on fludrocortisone, which was stopped before or during their sessions. Heart rate variability in the time domain (standard deviation of the beat-to-beat interval) increased post-HIRREM (mean increase 51%, range 10-143, p = 0.03), as did baroreflex sensitivity (mean increase in high-frequency alpha 65%, range -6 to 180, p = 0.05). Baseline temporal electrical asymmetry negatively correlated with change in asymmetry from assessment to the final HIRREM session (p = 0.01). Summed high-frequency amplitudes at left and right temporal lobes decreased a median of 3.8 μV (p = 0.02). There was a trend for improvements in self-reported symptoms related to the autonomic nervous system. Use of HIRREM was associated with reduced sympathetic bias in autonomic cardiovascular regulation, greater symmetry and reduced amplitudes in temporal lobe high-frequency electrical activity, and a trend for reduced autonomic symptoms. Data suggest the potential for allostatic neurotechnology to facilitate increased flexibility in autonomic cardiovascular regulation, possibly through more balanced activity at regions of the neocortex responsible for autonomic management. Clinical trial registry "Tilt Table with Suspected postural orthostatic tachycardia syndrome (POTS) Subjects," Protocol Record: WFUBAHA01.
Heart Rate Variability and Wavelet-based Studies on ECG Signals from Smokers and Non-smokers
NASA Astrophysics Data System (ADS)
Pal, K.; Goel, R.; Champaty, B.; Samantray, S.; Tibarewala, D. N.
2013-12-01
The current study deals with the heart rate variability (HRV) and wavelet-based ECG signal analysis of smokers and non-smokers. The results of HRV indicated dominance towards the sympathetic nervous system activity in smokers. The heart rate was found to be higher in case of smokers as compared to non-smokers ( p < 0.05). The frequency domain analysis showed an increase in the LF and LF/HF components with a subsequent decrease in the HF component. The HRV features were analyzed for classification of the smokers from the non-smokers. The results indicated that when RMSSD, SD1 and RR-mean features were used concurrently a classification efficiency of > 90 % was achieved. The wavelet decomposition of the ECG signal was done using the Daubechies (db 6) wavelet family. No difference was observed between the smokers and non-smokers which apparently suggested that smoking does not affect the conduction pathway of heart.
Mather, Mara; Yoo, Hyun Joo; Clewett, David V.; Lee, Tae-Ho; Greening, Steven G.; Ponzio, Allison; Min, Jungwon; Thayer, Julian F.
2017-01-01
The locus coeruleus (LC) is a key node of the sympathetic nervous system and suppresses parasympathetic activity that would otherwise increase heart rate variability. In the current study, we examined whether LC-MRI contrast reflecting neuromelanin accumulation in the LC was associated with high-frequency heart rate variability (HF-HRV), a measure reflecting parasympathetic influences on the heart. Recent evidence indicates that neuromelanin, a byproduct of catecholamine metabolism, accumulates in the LC through young and mid adulthood, suggesting that LC-MRI contrast may be a useful biomarker of individual differences in habitual LC activation. We found that, across younger and older adults, greater LC-MRI contrast was negatively associated with HF-HRV during fear conditioning and spatial detection tasks. This correlation was not accounted for by individual differences in age or anxiety. These findings indicate that individual differences in LC structure relate to key cardiovascular parameters. PMID:28215623
Frequency of Loaded Road March Training and Performance on a Loaded Road March
1990-04-01
heart rate through the use of beta - blockers can substantially improve shooting accuracy (29, 44). Post road march decrements in the grenade throw may...the road march. An Increase in body tremors due to fatigue or an elevated post exercise heart rate may account for this. Whole body sway while aiming...a rifle is substantially increased even after a short period of exercise (39) and this may effect accuracy. Muscle tremors increase after brief or
Does Mckuer's Law Hold for Heart Rate Control via Biofeedback Display?
NASA Technical Reports Server (NTRS)
Courter, B. J.; Jex, H. R.
1984-01-01
Some persons can control their pulse rate with the aid of a biofeedback display. If the biofeedback display is modified to show the error between a command pulse-rate and the measured rate, a compensatory (error correcting) heart rate tracking control loop can be created. The dynamic response characteristics of this control loop when subjected to step and quasi-random disturbances were measured. The control loop includes a beat-to-beat cardiotachmeter differenced with a forcing function from a quasi-random input generator; the resulting error pulse-rate is displayed as feedback. The subject acts to null the displayed pulse-rate error, thereby closing a compensatory control loop. McRuer's Law should hold for this case. A few subjects already skilled in voluntary pulse-rate control were tested for heart-rate control response. Control-law properties are derived, such as: crossover frequency, stability margins, and closed-loop bandwidth. These are evaluated for a range of forcing functions and for step as well as random disturbances.
Estimation of body temperature rhythm based on heart activity parameters in daily life.
Sooyoung Sim; Heenam Yoon; Hosuk Ryou; Kwangsuk Park
2014-01-01
Body temperature contains valuable health related information such as circadian rhythm and menstruation cycle. Also, it was discovered from previous studies that body temperature rhythm in daily life is related with sleep disorders and cognitive performances. However, monitoring body temperature with existing devices during daily life is not easy because they are invasive, intrusive, or expensive. Therefore, the technology which can accurately and nonintrusively monitor body temperature is required. In this study, we developed body temperature estimation model based on heart rate and heart rate variability parameters. Although this work was inspired by previous research, we originally identified that the model can be applied to body temperature monitoring in daily life. Also, we could find out that normalized Mean heart rate (nMHR) and frequency domain parameters of heart rate variability showed better performance than other parameters. Although we should validate the model with more number of subjects and consider additional algorithms to decrease the accumulated estimation error, we could verify the usefulness of this approach. Through this study, we expect that we would be able to monitor core body temperature and circadian rhythm from simple heart rate monitor. Then, we can obtain various health related information derived from daily body temperature rhythm.
Sleight, P; La Rovere, M T; Mortara, A; Pinna, G; Maestri, R; Leuzzi, S; Bianchini, B; Tavazzi, L; Bernardi, L
1995-01-01
1. It is often assumed that the power in the low- (around 0.10 Hz) and high-frequency (around 0.25 Hz) bands obtained by power spectral analysis of cardiovascular variables reflects sympathetic and vagal tone [corrected] respectively. An alternative model attributes the low-frequency band to a resonance in the control system that is produced by the inefficiently slow time constant of the reflex response to beat-to-beat changes in blood pressure effected by the sympathetic (with or without the parasympathetic) arm(s) of the baroreflex (De Boer model). 2. We have applied the De Boer model of circulatory variability to patients with varying baroreflex sensitivity to patients with varying baroreflex sensitivity and one normal subject, and have shown that the main differences in spectral power (for both low and high frequency) between and within subjects are caused by changes in the arterial baroreflex gain, particularly for vagal control of heart rate (R-R interval) and left ventricular stroke output. We have computed the power spectrum at rest and during neck suction (to stimulate carotid baroreceptors). We stimulated the baroreceptors at two frequencies (0.1 and 0.2 Hz), which were both distinct from the controlled respiration rate (0.25 Hz), in both normal subjects and heart failure patients with either sensitive or poor baroreflex control. 3. The data broadly confirm the De Boer model. The low-frequency (0.1 Hz) peak in either R-R or blood pressure variability) was spontaneously generated only if the baroreflex control of the autonomic outflow was relatively intact.(ABSTRACT TRUNCATED AT 250 WORDS)
Effects of whole body heating on dynamic baroreflex regulation of heart rate in humans
NASA Technical Reports Server (NTRS)
Crandall, C. G.; Zhang, R.; Levine, B. D.
2000-01-01
The purpose of this project was to identify whether dynamic baroreflex regulation of heart rate (HR) is altered during whole body heating. In 14 subjects, dynamic baroreflex regulation of HR was assessed using transfer function analysis. In normothermic and heat-stressed conditions, each subject breathed at a fixed rate (0. 25 Hz) while beat-by-beat HR and systolic blood pressure (SBP) were obtained. Whole body heating significantly increased sublingual temperature, HR, and forearm skin blood flow. Spectral analysis of HR and SBP revealed that the heat stress significantly reduced HR and SBP variability within the high-frequency range (0.2-0.3 Hz), reduced SBP variability within the low-frequency range (0.03-0.15 Hz), and increased the ratio of low- to high-frequency HR variability (all P < 0.01). Transfer function gain analysis showed that the heat stress reduced dynamic baroreflex regulation of HR within the high-frequency range (from 1.04 +/- 0.06 to 0.54 +/- 0.6 beats. min(-1). mmHg(-1); P < 0.001) without significantly affecting the gain in the low-frequency range (P = 0.63). These data suggest that whole body heating reduced high-frequency dynamic baroreflex regulation of HR associated with spontaneous changes in blood pressure. Reduced vagal baroreflex regulation of HR may contribute to reduced orthostatic tolerance known to occur in humans during heat stress.
NASA Astrophysics Data System (ADS)
Osaka, Motohisa; Murata, Hiroshige; Tateoka, Katsuhiko; Katoh, Takao
2007-07-01
Some cases of traffic accidents are assumed to be due to the occurrences of cardiac events during driving, which are thought to be induced by imbalance of autonomic nervous activities. These can be measured by analyzing heart rate variability. Therefore, we developed a new system of steering-wheel electrocardiogram with a soft-ware to remove noises. We compared the trends of sympathetic and parasympathetic nerve activities measured from the steering-wheel electrocardiograms with those recorded simultaneously from chest leads. For each parameter of instantaneous heart rate, low- or high-frequency component of heart rate variability in all the cases, the trend from the steering-wheel electrocardiogram resembled that from the chest-lead electrocardiogram. In 3 of 7 subjects, the trend of LF/HF showed a strong relationship between the steering-wheel electrocardiogram and the chest-lead electrocardiogram. Our system will open doors to a new strategy to keep a driver out of a risk by notifying it while driving.
Practical remarks on the heart rate and saturation measurement methodology
NASA Astrophysics Data System (ADS)
Kowal, M.; Kubal, S.; Piotrowski, P.; Staniec, K.
2017-05-01
A surface reflection-based method for measuring heart rate and saturation has been introduced as one having a significant advantage over legacy methods in that it lends itself for use in special applications such as those where a person’s mobility is of prime importance (e.g. during a miner’s work) and excluding the use of traditional clips. Then, a complete ATmega1281-based microcontroller platform has been described for performing computational tasks of signal processing and wireless transmission. In the next section remarks have been provided regarding the basic signal processing rules beginning with raw voltage samples of converted optical signals, their acquisition, storage and smoothing. This chapter ends with practical remarks demonstrating an exponential dependence between the minimum measurable heart rate and the readout resolution at different sampling frequencies for different cases of averaging depth (in bits). The following section is devoted strictly to the heart rate and hemoglobin oxygenation (saturation) measurement with the use of the presented platform, referenced to measurements obtained with a stationary certified pulsoxymeter.
Pittig, Andre; Arch, Joanna J; Lam, Chi W R; Craske, Michelle G
2013-01-01
It remains unclear if diminished high frequency heart rate variability (HF-HRV) can be found across anxiety disorders. HF-HRV and heart rate (HR) were examined in panic (PD), generalized anxiety (GAD), social anxiety (SAD), and obsessive-compulsive disorder (OCD) relative to healthy controls at baseline and during anxiety stressors. All disorders evidenced diminished baseline HF-HRV relative to controls. Baseline HRV differences were maintained throughout relaxation. For hyperventilation, PD and GAD demonstrated greater HR than controls. Psychotropic medication did not account for HF-HRV differences except in OCD. Age and sex evidenced multiple main effects. Findings suggest that low baseline HF-HRV represents a common index for inhibitory deficits across PD, GAD, and SAD, which is consistent with the notion of autonomic inflexibility in anxiety disorders. Elevated HR responses to hyperventilation, however, are specific to PD and GAD. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Casper, Patricia A.; Kantowitz, Barry H.
1988-01-01
Multiple approaches are necessary for understanding and measuring workload. In particular, physiological systems identifiable by employing cardiac measures are related to cognitive systems. One issue of debate in measuring cardiac output is the grain of analysis used in recording and summarizing data. Various experiments are reviewed, the majority of which were directed at supporting or contradicting Lacey's intake-rejection hypothesis. Two of the experiments observed heart rate in operational environments and found virtually no changes associated with mental load. The major problems facing researchers using heart rate variability, or sinus arrhthmia, as a dependent measure have been associated with valid and sensitive scoring and preventing contamination of observed results by influences unrelated to cognition. Spectral analysis of heart rate variability offers two useful procedures: analysis from the time domain and analysis from the frequency domain. Most recently, data have been collected in a divided attention experiment, the performance measures and cardiac measures of which are detailed.
Cardiac autonomic modulation impairments in advanced breast cancer patients.
Arab, Claudia; Vanderlei, Luiz Carlos Marques; da Silva Paiva, Laércio; Fulghum, Kyle Levi; Fristachi, Carlos Elias; Nazario, Afonso Celso Pinto; Elias, Simone; Gebrim, Luiz Henrique; Ferreira Filho, Celso; Gidron, Yori; Ferreira, Celso
2018-05-02
To compare cardiac autonomic modulation in early- versus advanced-stage breast cancer patients before any type of cancer treatment and investigate associated factors. This cross-sectional study included women (30-69 years old) with primary diagnosis of breast cancer and women with benign breast tumors. We evaluated cardiac modulation by heart rate variability and assessed factors of anxiety, depression, physical activity, and other relevant medical variables. Patients were divided into three groups based on TNM staging of cancer severity: early-stage cancer (n = 42), advanced-stage cancer (n = 37), or benign breast tumors to serve as a control (n = 37). We analyzed heart rate variability in time and frequency domains. The advanced-stage cancer group had lower vagal modulation than early-stage and benign groups; also, the advance-stage group had lower overall heart rate variability when compared to benign conditions. Heart rate variability was influenced by age, menopausal status, and BMI. Heart rate variability seems to be a promising, non-invasive tool for early diagnosis of autonomic dysfunction in breast cancer and detection of cardiovascular impairments at cancer diagnosis. Cardiac autonomic modulation is inversely associated with breast cancer staging.
Mak, Susanna; Van Spall, Harriette G C; Wainstein, Rodrigo V; Sasson, Zion
2012-03-01
The aim of this study was to examine the effect of heart rate (HR) on indices of deformation in adults with and without heart failure (HF) who underwent simultaneous high-fidelity catheterization of the left ventricle to describe the force-frequency relationship. Right atrial pacing to control HR and high-fidelity recordings of left ventricular (LV) pressure were used to inscribe the force-frequency relationship. Simultaneous two-dimensional echocardiographic imaging was acquired for speckle-tracking analysis. Thirteen patients with normal LV function and 12 with systolic HF (LV ejection fraction, 31 ± 13%) were studied. Patients with HF had depressed isovolumic contractility and impaired longitudinal strain and strain rate. HR-dependent increases in LV+dP/dt(max), the force-frequency relationship, was demonstrated in both groups (normal LV function, baseline to 100 beats/min: 1,335 ± 296 to 1,564 ± 320 mm Hg/sec, P < .0001; HF, baseline to 100 beats/min: 970 ± 207 to 1,083 ± 233 mm Hg/sec, P < .01). Longitudinal strain decreased significantly (normal LV function, baseline to 100 beats/min: 18.0 ± 3.5% to 10.8 ± 6.0%, P < .001; HF: 9.4 ± 4.1% to 7.5 ± 3.4%, P < .01). The decrease in longitudinal strain was related to a decrease in LV end-diastolic dimensions. Strain rate did not change with right atrial pacing. Despite the inotropic effect of increasing HR, longitudinal strain decreases in parallel with stroke volume as load-dependent indices of ejection. Strain rate did not reflect the modest HR-related changes in contractility; on the other hand, the use of strain rate for quantitative stress imaging is also less likely to be confounded by chronotropic responses. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Pulse transducer with artifact signal attenuator. [heart rate sensors
NASA Technical Reports Server (NTRS)
Cash, W. H., Jr.; Polhemus, J. T. (Inventor)
1980-01-01
An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.
Vora, Rathin; Zareba, Wojciech; Utell, Mark J; Pietropaoli, Anthony P; Chalupa, David; Little, Erika L; Oakes, David; Bausch, Jan; Wiltshire, Jelani; Frampton, Mark W
2014-07-16
Diabetes may confer an increased risk for the cardiovascular health effects of particulate air pollution, but few human clinical studies of air pollution have included people with diabetes. Ultrafine particles (UFP, ≤100 nm in diameter) have been hypothesized to be an important component of particulate air pollution with regard to cardiovascular health effects. 17 never-smoker subjects 30-60 years of age, with stable type 2 diabetes but otherwise healthy, inhaled either filtered air (0-10 particles/cm3) or elemental carbon UFP (~107 particles/cm3, ~50 ug/m3, count median diameter 32 nm) by mouthpiece, for 2 hours at rest, in a double-blind, randomized, crossover study design. A digital 12-lead electrocardiogram (ECG) was recorded continuously for 48 hours, beginning 1 hour prior to exposure. Analysis of 5-minute segments of the ECG during quiet rest showed reduced high-frequency heart rate variability with UFP relative to air exposure (p = 0.014), paralleled by non-significant reductions in time-domain heart rate variability parameters. In the analysis of longer durations of the ECG, we found that UFP exposure increased the heart rate relative to air exposure. During the 21- to 45-hour interval after exposure, the average heart rate increased approximately 8 beats per minute with UFP, compared to 5 beats per minute with air (p = 0.045). There were no UFP effects on cardiac rhythm or repolarization. Inhalation of elemental carbon ultrafine particles alters heart rate and heart rate variability in people with type 2 diabetes. Our findings suggest that effects may occur and persist hours after a single 2-hour exposure.
Computerized analysis of fetal heart rate variability signal during the stages of labor.
Annunziata, Maria Laura; Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Giuliano, Natascia; Mereghini, Flavia; Di Lieto, Andrea; Campanile, Marta
2016-03-01
To analyze computerized cardiotocographic (cCTG) parameters (baseline fetal heart rate, baseline FHR; short term variability, STV; approximate entropy, ApEn; low frequency, LF; movement frequency, MF; high frequency, HF) in physiological pregnancy in order to correlate them with the stages of labor. This could provide more information for understanding the mechanisms of nervous system control of FHR during labor progression. A total of 534 pregnant women were monitored on cCTG from the 37th week before the onset of spontaneous labor and during the first and the second stage of labor. Statistical analysis was performed using Kruskal-Wallis test and Wilcoxon rank-sum test with the Bonferroni adjusted α (< 0.05). Statistically significant differences were seen between baseline FHR, MF and HF (P < 0.001), in which the first two were reduced and the third was increased when compared between pre-labor, and the first and second stages of labor. Differences between some of the stages were found for ApEn, LF and for LF/(HF + MF), where the first and the third were reduced and the second was increased. cCTG modifications during labor may reflect the physiologic increased activation of the autonomous nervous system. Using computerized fetal heart rate analysis during labor it may be possible to obtain more information from the fetal cardiac signal, in comparison with the traditional tracing. © 2016 Japan Society of Obstetrics and Gynecology.
The forgotten role of central volume in low frequency oscillations of heart rate variability.
Ferrario, Manuela; Moissl, Ulrich; Garzotto, Francesco; Cruz, Dinna N; Tetta, Ciro; Signorini, Maria G; Ronco, Claudio; Grassmann, Aileen; Cerutti, Sergio; Guzzetti, Stefano
2015-01-01
The hypothesis that central volume plays a key role in the source of low frequency (LF) oscillations of heart rate variability (HRV) was tested in a population of end stage renal disease patients undergoing conventional hemodialysis (HD) treatment, and thus subject to large fluid shifts and sympathetic activation. Fluid overload (FO) in 58 chronic HD patients was assessed by whole body bioimpedance measurements before the midweek HD session. Heart Rate Variability (HRV) was measured using 24-hour Holter electrocardiogram recordings starting before the same HD treatment. Time domain and frequency domain analyses were performed on HRV signals. Patients were retrospectively classified in three groups according to tertiles of FO normalized to the extracellular water (FO/ECW%). These groups were also compared after stratification by diabetes mellitus. Patients with the low to medium hydration status before the treatment (i.e. 1st and 2nd FO/ECW% tertiles) showed a significant increase in LF power during last 30 min of HD compared to dialysis begin, while no significant change in LF power was seen in the third group (i.e. those with high pre-treatment hydration values). In conclusion, several mechanisms can generate LF oscillations in the cardiovascular system, including baroreflex feedback loops and central oscillators. However, the current results emphasize the role played by the central volume in determining the power of LF oscillations.
Cheng, Tzu-Han; Tsai, Chen-Gia
2016-01-01
Although music and the emotion it conveys unfold over time, little is known about how listeners respond to shifts in musical emotions. A special technique in heavy metal music utilizes dramatic shifts between loud and soft passages. Loud passages are penetrated by distorted sounds conveying aggression, whereas soft passages are often characterized by a clean, calm singing voice and light accompaniment. The present study used heavy metal songs and soft sea sounds to examine how female listeners' respiration rates and heart rates responded to the arousal changes associated with auditory stimuli. The high-frequency power of heart rate variability (HF-HRV) was used to assess cardiac parasympathetic activity. The results showed that the soft passages of heavy metal songs and soft sea sounds expressed lower arousal and induced significantly higher HF-HRVs than the loud passages of heavy metal songs. Listeners' respiration rate was determined by the arousal level of the present music passage, whereas the heart rate was dependent on both the present and preceding passages. Compared with soft sea sounds, the loud music passage led to greater deceleration of the heart rate at the beginning of the following soft music passage. The sea sounds delayed the heart rate acceleration evoked by the following loud music passage. The data provide evidence that sound-induced parasympathetic activity affects listeners' heart rate in response to the following music passage. These findings have potential implications for future research on the temporal dynamics of musical emotions.
Zarei, Ali Asghar; Foroutan, Seyyed Abbas; Foroutan, Seyyed Mohsen; Erfanian Omidvar, Abbas
2011-01-01
Pyridostigmine bromide (PB) is a reversible cholinesterase inhibitor. The aim of this study was to determine the effect of orally administration of single dose sustained-released tablet of pyridostigmine bromide (PBSR) on the frequency domain indices of heart rate variability (HRV). Thirty-two healthy young men were participated in this study. They were divided into 2 groups; the pyridostigmine group (n = 22) and the placebo group (n = 10). Electrocardiogram (ECG) was recorded at 10, 30, 60, 90, 120, 150, 180, 210, 240, 300 and 420 min after PBSR administration. At each time, simultaneously, a blood sample was prepared and PB plasma concentration was measured by high-performance liquid chromatography (HPLC) method. Statistical analysis showed that in different indices of HRV, there is a significant increase in low frequency (LF) band at 300 min, but no difference in high frequency band (HF). It also showed significant decreases in normalized high frequency band (Hfnu), normalized low frequency band (Lfnu) and LF/HF ratio at 120, 240 and 300 min after PBSR administration. Maximum plasma concentration of PB was 150 min after the administration. In conclusion, administration of a single dose PBSR can enhance the frequency domains indices of HRV and improvesympathovagal balance. PMID:24250427
Shiba, Kenji; Nukaya, Masayuki; Tsuji, Toshio; Koshiji, Kohji
2008-01-01
This paper reports on the current density and specific absorption rate (SAR) analysis of biological tissue surrounding an air-core transcutaneous transformer for an artificial heart. The electromagnetic field in the biological tissue is analyzed by the transmission line modeling method, and the current density and SAR as a function of frequency, output voltage, output power, and coil dimension are calculated. The biological tissue of the model has three layers including the skin, fat, and muscle. The results of simulation analysis show SARs to be very small at any given transmission conditions, about 2-14 mW/kg, compared to the basic restrictions of the International Commission on nonionizing radiation protection (ICNIRP; 2 W/kg), while the current density divided by the ICNIRP's basic restrictions gets smaller as the frequency rises and the output voltage falls. It is possible to transfer energy below the ICNIRP's basic restrictions when the frequency is over 250 kHz and the output voltage is under 24 V. Also, the parts of the biological tissue that maximized the current density differ by frequencies; in the low frequency is muscle and in the high frequency is skin. The boundary is in the vicinity of the frequency 600-1000 kHz.
Amano, Tatsuro; Ishitobi, Masaki; Ogura, Yukio; Inoue, Yoshimitsu; Koga, Shunsaku; Nishiyasu, Takeshi; Kondo, Narihiko
2016-10-01
Changing stride frequency may influence oxygen uptake and heart rate during running as a function of running economy and central command. This study investigated the influence of stride frequency manipulation on thermoregulatory responses during endurance running. Seven healthy endurance runners ran on a treadmill at a velocity of 15km/h for 60min in a controlled environmental chamber (ambient temperature 27°C and relative humidity 50%), and stride frequency was manipulated. Stride frequency was intermittently manipulated by increasing and decreasing frequency by 10% from the pre-determined preferred frequency. These periods of increase or decrease were separated by free frequency running in the order of free stride frequency, stride frequency manipulation (increase or decrease), free stride frequency, and stride frequency manipulation (increase or decrease) for 15min each. The increased and decreased stride frequencies were 110% and 91% of the free running frequency, respectively (196±6, 162±5, and 178±5steps/min, respectively, P<0.01). Compared to the control, stride frequency manipulation did not affect rectal temperature, heart rate, or the rate of perceived exhaustion during running. Whole-body sweat loss increased significantly when stride frequency was manipulated (1.48±0.11 and 1.57±0.11kg for control and manipulated stride frequencies, respectively, P<0.05), but stride frequency had a small effect on sweat loss overall (Cohen's d=0.31). A higher mean skin temperature was also observed under mixed frequency conditions compared to that in the control (P<0.05). While the precise mechanisms underlying these changes remain unknown (e.g. running economy or central command), our results suggest that manipulation of stride frequency does not have a large effect on sweat loss or other physiological variables, but does increase mean skin temperature during endurance running. Copyright © 2016. Published by Elsevier Ltd.
Kalisnik, Jurij M; Avbelj, Viktor; Trobec, Roman; Ivaskovic, Daroslav; Vidmar, Gaj; Troise, Giovanni; Gersak, Borut
2006-01-01
Altered autonomic regulation precipitates cardiac arrhythmias and increases the risk of sudden cardiac death. This risk is further increased by changes in ventricular repolarization. Autonomic regulation is deranged in patients after myocardial on-pump revascularization. We aimed to clarify how off-pump coronary artery bypass grafting (CABG) affects postoperative cardiac autonomic regulation and ventricular repolarization within 4 weeks after CABG. Forty-two patients (mean age, 61.9 +/- 9.3 years; mean EURO score 2.6 +/- 1.9) were electively admitted for off-pump CABG. The electrocardiographic and respiratory waveform recordings were performed in the afternoon in the supine position for 10 minutes. Autonomic modulation was assessed using heart rate variability analysis. Power spectra were computed from 5-minute stable RR intervals using Fourier Transform analysis. Total power of spectra was defined in the range of 0.01 to 0.40 Hz, high-frequency power within 0.15 to 0.40 Hz, and low-frequency power within 0.04 to 0.15 Hz. Normalized power was defined as a ratio of power in each band/total power. The high- and low-frequency power as well as their normalized values indicated cardiac vagal and sympathetic modulation, respectively. Ventricular repolarization was assessed using QT interval, QT interval variability, and QT-RR interdependence analysis. QT intervals were determined from the beginning of the 5-minute segments. QT interval variability was evaluated by a T-wave template-matching algorithm. Pearson correlation between length of RR and QT interval was applied to study QT-RR characteristics. The results were tested for significance using the Fisher exact test, nonpaired t test, and analysis of variance; a P <.05 was considered significant. The frequency of arrhythmic events and heart rate increased from the fourth to the seventh postoperative day and returned to preoperative levels 4 weeks after CABG. Heart rate variability measures indicating autonomic modulation remained depressed even 4 weeks after the procedure. QT variability index increased from -1.2 +/- 0.5 to -0.8 +/- 0.4 on the fourth day after the operation (P <.05) and returned to -1.0 +/- 0.5 4 weeks after CABG (P = not significant). QT-RR correlation decreased from 0.41 to 0.23 (P <.05) and remained significantly impaired as long as 4 weeks after CABG. Observed faster heart rates until 1 week after off-pump CABG imply excessive adrenergic activation, which is comparable to on-pump CABG procedure rates. The results indicate profound autonomic derangement and loss of rate-dependent regulation after off-pump CABG even 4 weeks after operation. Restituted repolarization as assessed by QT variability index 4 weeks postoperatively corresponded with decreased frequency of rhythm disturbances 4 weeks after CABG. The loss of coupling between QT and RR intervals shows increased electrical instability postoperatively, which may serve as an additional promoter for postoperative arrhythmias, especially at higher heart rates.
Power spectral analysis of heart rate in hyperthyroidism.
Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M
1996-08-01
The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P < 0.01); standing, 6.0 +/- 2.7 vs. 15.0 +/- 4.0 NU (P < 0.01); mean +/- SEM]. On the other hand components were comparable in the 2 groups (lying, 64.0 +/- 6.9 vs. 62.0 +/- 6.5 NU; standing, 77.0 +/- 6.5 vs. 78.0 +/- 5.4 NU). Hence, the LF/HF ratio, which is considered an index of sympathovagal balance, was increased in hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P < 0.05) and standing (54.0 +/- 12.6 vs. 9.8 +/- 2.6; P < 0.02). This parameter was positively correlated with both T3 (r = 0.61; P < 0.05) and free T4 (r = 0.63; P < 0.05) serum levels. Among traditional cardiovascular autonomic tests, the reflex response of heart rate during lying to standing was significantly lower in hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P < 0.002). No statistically significant difference in reflex responses between the two groups was found in deep breathing or Valsalva's maneuver. In the 8 patients reexamined after methimazole treatment, we observed complete normalization of altered cardiovascular parameters, with slight predominance of the vagal component compared with controls. These results suggest that thyroid hormone excess may determine reduced parasympathetic activity and, thus, a relative hypersympathetic tone.
Harris, Patricia R E; Stein, Phyllis K; Fung, Gordon L; Drew, Barbara J
2014-01-01
This study sought to examine the prognostic value of heart rate variability (HRV) measurement initiated immediately after emergency department presentation for patients with acute coronary syndrome (ACS). Altered HRV has been associated with adverse outcomes in heart disease, but the value of HRV measured during the earliest phases of ACS related to risk of 1-year rehospitalization and death has not been established. Twenty-four-hour Holter recordings of 279 patients with ACS were initiated within 45 minutes of emergency department arrival; recordings with ≥18 hours of sinus rhythm were selected for HRV analysis (number [N] =193). Time domain, frequency domain, and nonlinear HRV were examined. Survival analysis was performed. During the 1-year follow-up, 94 patients were event-free, 82 were readmitted, and 17 died. HRV was altered in relation to outcomes. Predictors of rehospitalization included increased normalized high frequency power, decreased normalized low frequency power, and decreased low/high frequency ratio. Normalized high frequency >42 ms(2) predicted rehospitalization while controlling for clinical variables (hazard ratio [HR] =2.3; 95% confidence interval [CI] =1.4-3.8, P=0.001). Variables significantly associated with death included natural logs of total power and ultra low frequency power. A model with ultra low frequency power <8 ms(2) (HR =3.8; 95% CI =1.5-10.1; P=0.007) and troponin >0.3 ng/mL (HR =4.0; 95% CI =1.3-12.1; P=0.016) revealed that each contributed independently in predicting mortality. Nonlinear HRV variables were significant predictors of both outcomes. HRV measured close to the ACS onset may assist in risk stratification. HRV cut-points may provide additional, incremental prognostic information to established assessment guidelines, and may be worthy of additional study.
Xiong, Li; Tian, Ge; Wang, Li; Lin, Wenhua; Chen, Xiangyan; Leung, Thomas Wai Hong; Soo, Yannie Oi Yan; Wong, Lawrence Ka Sing
2017-07-01
External counterpulsation (ECP) is a noninvasive method used to augment cerebral perfusion in ischemic stroke. However, the response of beat-to-beat heart rate variability (HRV) in patients with ischemic stroke during ECP remains unknown. Forty-eight patients with unilateral ischemic stroke at the subacute stage and 14 healthy controls were recruited. Beat-to-beat heart rate before, during, and after ECP was monitored. The frequency components of HRV were calculated using power spectral analysis. Very low frequency (VLF; <.04 Hz), low frequency (LF; .04-.15 Hz), high frequency (HF; .15-.40 Hz), total power spectral density (TP; <.40 Hz), and LF/HF ratio were calculated. In stroke patients, although there were no statistical differences in all of the HRV components, the HRV at VLF showed a trend of increase during ECP compared with baseline in the left-sided stroke patients (P = .083). After ECP, the HRV at LF and TP remained higher than baseline in the right-sided stroke patients (LF, 209.4 versus 117.9, P = .050; TP, 1275.6 versus 390.2, P = .017, respectively). Besides, the HRV at TP also increased after ECP compared with baseline in the left-sided stroke patients (563.0 versus 298.3, P = .029). Irrespective of the side of the ischemia, patients showed an increased beat-to-beat HRV after ECP. Additionally, sympathetic and parasympathetic cardiac modulations were increased after ECP in patients after right-sided subacute stroke. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Borges, Nattai R; Reaburn, Peter R; Doering, Thomas M; Argus, Christos K; Driller, Matthew W
2017-04-01
This study aimed at examining the autonomic cardiovascular modulation in well-trained masters and young cyclists following high-intensity interval training (HIT). Nine masters (age 55.6 ± 5.0 years) and eight young cyclists (age 25.9 ± 3.0 years) completed a HIT protocol of 6 x 30 sec at 175% of peak power output, with 4.5-min' rest between efforts. Immediately following HIT, heart rate and R-R intervals were monitored for 30-min during passive supine recovery. Autonomic modulation was examined by i) heart rate recovery in the first 60-sec of recovery (HRR 60 ); ii) the time constant of the 30-min heart rate recovery curve (HRRτ); iii) the time course of the root mean square for successive 30-sec R-R interval (RMSSD 30 ); and iv) time and frequency domain analyses of subsequent 5-min R-R interval segments. No significant between-group differences were observed for HRR 60 (P = 0.096) or HRR τ (P = 0.617). However, a significant interaction effect was found for RMSSD 30 (P = 0.021), with the master cyclists showing higher RMSSD 30 values following HIT. Similar results were observed in the time and frequency domain analyses with significant interaction effects found for the natural logarithm of the RMSSD (P = 0.008), normalised low-frequency power (P = 0.016) and natural logarithm of high-frequency power (P = 0.012). Following high-intensity interval training, master cyclists demonstrated greater post-exercise parasympathetic reactivation compared to young cyclists, indicating that physical training at older ages has significant effects on autonomic function.
Kilinc, Ozden; Cincin, Altug; Pehlivan, Aslihan; Midi, Ipek; Kepez, Alper; Agan, Kadriye
2016-06-01
Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures.
ARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.
Kaufmann, Tobias; Sütterlin, Stefan; Schulz, Stefan M; Vögele, Claus
2011-12-01
The importance of appropriate handling of artifacts in interbeat interval (IBI) data must not be underestimated. Even a single artifact may cause unreliable heart rate variability (HRV) results. Thus, a robust artifact detection algorithm and the option for manual intervention by the researcher form key components for confident HRV analysis. Here, we present ARTiiFACT, a software tool for processing electrocardiogram and IBI data. Both automated and manual artifact detection and correction are available in a graphical user interface. In addition, ARTiiFACT includes time- and frequency-based HRV analyses and descriptive statistics, thus offering the basic tools for HRV analysis. Notably, all program steps can be executed separately and allow for data export, thus offering high flexibility and interoperability with a whole range of applications.
Change in heart rate variability after the adult attachment interview in dissociative patients.
Farina, Benedetto; Speranza, Anna Maria; Imperatori, Claudio; Quintiliani, Maria Isabella; Della Marca, Giacomo
2015-01-01
The aim of this study was to assess heart rate variability (HRV) in individuals with dissociative disorders (DD) before and after the Adult Attachment Interview (AAI). Electrocardiograms were recorded before, during, and after the AAI in 13 individuals with DD and 13 healthy participants matched for age and gender. Significant change in HRV was observed only in the DD group. After the AAI, those with DD showed significant increases in the low frequency/high frequency ratio (pre-AAI = 1.91 ± 1.19; post-AAI = 4.03 ± 2.40; Wilcoxon test = -2.76, p = .005). Our results suggest that the retrieval of childhood attachment experiences in individuals with DD is associated with a change in HRV patterns that could reflect the emotion dysregulation of dissociative psychopathological processes.
Khiabani, Hassan Z; Mørland, Jørg; Bramness, Jørgen G
2008-12-01
Delta 9-tetrahydrocannabinol (THC) is the major active component of cannabis. Cardiovascular effects of THC have previously been reported: tachycardia after intake, but also bradycardia at higher doses. The purpose of this study was, firstly, to investigate the frequency and irregularity of heart rate in a group of cannabis users in their natural surroundings. We also compared THC-positive drivers with a regular pulse with THC-positive drivers with an irregular pulse. The division of Forensic Toxicology and Drug Abuse (DFTDA) at the Norwegian Institute of Public Heath analyzes blood samples from all drivers suspected of driving under the influence of drugs. We studied pulse rate and regularity in 502 THC-positive drivers who tested negative for other substances. As a control group, we randomly selected 125 drug-negative cases from the database of the DFTDA; no alcohol, narcotics, or medicinal drugs of abuse were detected. The Delta9-THC-positive drivers had a higher mean pulse rate than the control group [82.8 beats/min (SD 16.3) versus 75.6 beats/min (SD 9.2)] and more cases with tachycardia were detected in the Delta9-THC-positive group (19.4% versus 1.6%). There was only one driver with an irregular heart beat in the control group, while there were nine among the Delta9-THC-positive drivers. The drivers with an irregular pulse were over-represented amongst those with the lowest blood Delta9-THC concentrations. This report represents a large study of subjects in a real-life situation and includes observations on pulse frequency, regularity, and blood Delta9-THC concentration. A substantial fraction of Delta9-THC-positive drivers had tachycardia, but there was no correlation between blood Delta9-THC concentration and pulse rate in the present study. We had no further diagnostic information on the cause of the pulse irregularities, but our results indicate that occasional users of cannabis tend to have irregular heart rates at low THC concentrations and at low pulse rates.
Carnevali, Luca; Trombini, Mimosa; Graiani, Gallia; Madeddu, Denise; Quaini, Federico; Landgraf, Rainer; Neumann, Inga D; Nalivaiko, Eugene; Sgoifo, Andrea
2014-04-10
In humans, there is a documented association between anxiety disorders and cardiovascular disease. Putative underlying mechanisms may include an impairment of the autonomic nervous system control of cardiac function. The primary objective of the present study was to characterize cardiac autonomic modulation and susceptibility to arrhythmias in genetic lines of rats that differ largely in their anxiety level. To reach this goal, electrocardiographic recordings were performed in high-anxiety behavior (HAB, n=10) and low-anxiety behavior (LAB, n=10) rats at rest, during stressful stimuli and under autonomic pharmacological manipulations, and analyzed by means of time- and frequency-domain indexes of heart rate variability. During resting conditions, HAB rats displayed a reduced heart rate variability, mostly in terms of lower parasympathetic (vagal) modulation compared to LAB rats. In HAB rats, this relatively low cardiac vagal control was associated with smaller heart rate responsiveness to acute stressors compared to LAB counterparts. In addition, beta-adrenergic pharmacological stimulation induced a larger incidence of ventricular tachyarrhythmias in HABs compared to LABs. At sacrifice, a moderate increase in heart-body weight ratio was observed in HAB rats. We conclude that high levels of anxiety-related behavior in rats are associated with signs of i) impaired autonomic modulation of heart rate (low vagally-mediated heart rate variability), ii) poor adaptive heart rate responsiveness to stressful stimuli, iii) increased arrhythmia susceptibility, and iv) cardiac hypertrophy. These results highlight the utility of the HAB/LAB model for investigating the mechanistic basis of the comorbidity between anxiety disorders and cardiovascular disease. Copyright © 2014 Elsevier Inc. All rights reserved.
Mabe, Abigail M; Hoover, Donald B
2011-07-05
Cardiac autonomic neuropathy is a frequent complication of diabetes and often presents as impaired cholinergic regulation of heart rate. Some have assumed that diabetics have degeneration of cardiac cholinergic nerves, but basic knowledge on this topic is lacking. Accordingly, our goal was to evaluate the structure and function of cardiac cholinergic neurons and nerves in C57BL/6 mice with streptozotocin-induced diabetes. Electrocardiograms were obtained weekly from conscious control and diabetic mice for 16 weeks. Resting heart rate decreased in diabetic mice, but intrinsic heart rate was unchanged. Power spectral analysis of electrocardiograms revealed decreased high frequency and increased low frequency power in diabetic mice, suggesting a relative reduction of parasympathetic tone. Negative chronotropic responses to right vagal nerve stimulation were blunted in 16-week diabetic mice, but postjunctional sensitivity of isolated atria to muscarinic agonists was unchanged. Immunohistochemical analysis of hearts from diabetic and control mice showed no difference in abundance of cholinergic neurons, but cholinergic nerve density was increased at the sinoatrial node of diabetic mice (16 weeks: 14.9±1.2% area for diabetics versus 8.9±0.8% area for control, P<0.01). We conclude that disruption of cholinergic function in diabetic mice cannot be attributed to a loss of cardiac cholinergic neurons and nerve fibers or altered cholinergic sensitivity of the atria. Instead, decreased responses to vagal stimulation might be caused by a defect of preganglionic cholinergic neurons and/or ganglionic neurotransmission. The increased density of cholinergic nerves observed at the sinoatrial node of diabetic mice might be a compensatory response. Copyright © 2011 Elsevier B.V. All rights reserved.
Increase in hospital admission rates for heart failure in The Netherlands, 1980-1993.
Reitsma, J. B.; Mosterd, A.; de Craen, A. J.; Koster, R. W.; van Capelle, F. J.; Grobbee, D. E.; Tijssen, J. G.
1996-01-01
OBJECTIVE: To study the trend in hospital admission rates for heart failure in the Netherlands from 1980 to 1993. DESIGN: All hospital admissions in the Netherlands with a principal discharge diagnosis of heart failure were analysed. In addition, individual records of heart failure patients from a subset of 7 hospitals were analysed to estimate the frequency and timing of readmissions. RESULTS: The total number of discharges for men increased from 7377 in 1980 to 13 022 in 1993, and for women from 7064 to 12 944. From 1980 through 1993 age adjusted discharge rates rose 48% for men and 40% for women. Age adjusted in-hospital mortality for heart failure decreased from 19% in 1980 to 15% in 1993. For all age groups in-hospital mortality for men was higher than for women. The mean length of hospital admissions in 1993 was 14.0 days for men and 16.4 days for women. A review of individual patient records from a 6.3% sample of all hospital admissions in the Netherlands indicated that within a 2 year period 18% of the heart failure patients were admitted more than once and 5% more than twice. CONCLUSIONS: For both men and women a pronounced increase in age adjusted discharge rates for heart failure was observed in the Netherlands from 1980 to 1993. Readmissions were a prominent feature among heart failure patients. Higher survival rates after acute myocardial infarction and the longer survival of patients with heart disease, including heart failure may have contributed to the observed increase. The importance of advances in diagnostic tools and of possible changes in admission policy remain uncertain. PMID:8944582
Baek, Hyun Jae; Shin, JaeWook; Jin, Gunwoo; Cho, Jaegeol
2017-10-24
Photoplethysmographic signals are useful for heart rate variability analysis in practical ambulatory applications. While reducing the sampling rate of signals is an important consideration for modern wearable devices that enable 24/7 continuous monitoring, there have not been many studies that have investigated how to compensate the low timing resolution of low-sampling-rate signals for accurate heart rate variability analysis. In this study, we utilized the parabola approximation method and measured it against the conventional cubic spline interpolation method for the time, frequency, and nonlinear domain variables of heart rate variability. For each parameter, the intra-class correlation, standard error of measurement, Bland-Altman 95% limits of agreement and root mean squared relative error were presented. Also, elapsed time taken to compute each interpolation algorithm was investigated. The results indicated that parabola approximation is a simple, fast, and accurate algorithm-based method for compensating the low timing resolution of pulse beat intervals. In addition, the method showed comparable performance with the conventional cubic spline interpolation method. Even though the absolute value of the heart rate variability variables calculated using a signal sampled at 20 Hz were not exactly matched with those calculated using a reference signal sampled at 250 Hz, the parabola approximation method remains a good interpolation method for assessing trends in HRV measurements for low-power wearable applications.
Kiyono, Ken; Hayano, Junichiro; Kwak, Shin; Watanabe, Eiichi; Yamamoto, Yoshiharu
2012-01-01
The correlates of indices of long-term ambulatory heart rate variability (HRV) of the autonomic nervous system have not been completely understood. In this study, we evaluated conventional HRV indices, obtained from the daytime (12:00–18:00) Holter recording, and a recently proposed non-Gaussianity index (λ; Kiyono et al., 2008) in 12 patients with multiple system atrophy (MSA) and 10 patients with Parkinson disease (PD), known to have varying degrees of cardiac vagal and sympathetic dysfunction. Compared with the age-matched healthy control group, the MSA patients showed significantly decreased HRV, most probably reflecting impaired vagal heart rate control, but the PD patients did not show such reduced variability. In both MSA and PD patients, the low-to-high frequency (LF/HF) ratio and the short-term fractal exponent α1, suggested to reflect the sympathovagal balance, were significantly decreased, as observed in congestive heart failure (CHF) patients with sympathetic overdrive. In contrast, the analysis of the non-Gaussianity index λ showed that a marked increase in intermittent and non-Gaussian HRV observed in the CHF patients was not observed in the MSA and PD patients with sympathetic dysfunction. These findings provide additional evidence for the relation between the non-Gaussian intermittency of HRV and increased sympathetic activity. PMID:22371705
Heart rate sensitive optical coherence angiography
NASA Astrophysics Data System (ADS)
Alvarez, Karl; Lopez-Tremoleda, Jordi; Donnan, Rob; Michael-Titus, Adina T.; Tomlins, Peter H.
2018-02-01
Optical coherence angiography (OCA) enables visualisation of three-dimensional micro-vasculature from optical coherence tomography data volumes. Typically, various statistical methods are used to discriminate static tissue from blood flow within vessels. In this paper, we introduce a new method that relies upon the beating heart frequency to isolate blood vessels from the surrounding tissue. Vascular blood flow is assumed to be more strongly modulated by the heart-beat compared to surrounding tissue and therefore short-time Fourier transform of sequential measurements can discriminate the two. Furthermore, it is demonstrated that adjacent B-Scans within an OCT data volume can provide the required sampling frequency. As such, the technique can be considered to be a spatially mapped variation of photoplethysmography (PPG), whereby each image voxel operates as a PPG detector. This principle is demonstrated using both a model system and in vivo for monitoring the vascular changes effected by traumatic brain injury in mice. In vivo measurements were acquired at an A-Scan rate of 10kHz to form a 500x500x512 (lateral x lateral x axial) pixel volume, enabling sequential sampling of the mouse heart rate in an expected range of 300-600 bpm. One of the advantages of this new OCA processing method is that it can be used in conjunction with existing algorithms as an additional filter for signal to noise enhancement.
Intrapartum amnioinfusion in women with oligohydramniosis. A prospective randomized trial.
Persson-Kjerstadius, N; Forsgren, H; Westgren, M
1999-02-01
To evaluate the effects of amnioinfusion in oligohydramniosis. During a 20-month period, patients at term with oligohydramniosis (amniotic fluid index less than 5 cm) at Huddinge University and Norrköping Hospitals were recruited for a prospective randomized study to evaluate amnioinfusion. Informed consent was obtained from 112 patients who met the entry criteria. Sixty subjects were randomized to amnioinfusion and 52 to the control group. Outcome parameters included fetal heart rate abnormalities, mode of delivery, Apgar score, pH in umbilical artery blood and need for neonatal intensive care. The cesarean section rate was significantly reduced in the amnio-infusion group (29% versus 13%, p=0.043). No difference in time from randomization to delivery was detected between the two groups. The frequency of ominous fetal heart rate tracings with a cervical dilatation of 0-3 cm was the same in the two groups. The frequency of such heart rate patterns after amnioinfusion was significantly lower than in the control group. Neonatal outcome, pH in the umbilical artery blood and need for neonatal intensive care did not differ between the two groups. The present study confirms the findings of other authors that amnioinfusion effectively reduces the number of cesarean sections in cases of oligohydramniosis.
Melkonian, D; Korner, A; Meares, R; Bahramali, H
2012-10-01
A novel method of the time-frequency analysis of non-stationary heart rate variability (HRV) is developed which introduces the fragmentary spectrum as a measure that brings together the frequency content, timing and duration of HRV segments. The fragmentary spectrum is calculated by the similar basis function algorithm. This numerical tool of the time to frequency and frequency to time Fourier transformations accepts both uniform and non-uniform sampling intervals, and is applicable to signal segments of arbitrary length. Once the fragmentary spectrum is calculated, the inverse transform recovers the original signal and reveals accuracy of spectral estimates. Numerical experiments show that discontinuities at the boundaries of the succession of inter-beat intervals can cause unacceptable distortions of the spectral estimates. We have developed a measure that we call the "RR deltagram" as a form of the HRV data that minimises spectral errors. The analysis of the experimental HRV data from real-life and controlled breathing conditions suggests transient oscillatory components as functionally meaningful elements of highly complex and irregular patterns of HRV. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Duarte, Joana; Pinto-Gouveia, José
2017-11-01
There has been an increased interest in the study of underlying autonomic correlates of emotions. This study tests the hypothesis that high levels of high-frequency heart rate variability (HF HRV) are associated with positive emotions. In addition, we hypothesize that this association will differ according to the type of positive emotion. Also, based on recent findings, we tested the hypothesis that this relationship would be nonlinear. Resting-state HRV was collected and self-report measures of different positive emotions were administered to a sample of 124 volunteers. Results suggested that there was a quadratic relationship between high-frequency heart rate variability and positive emotions associated with safeness and contentment, but not with positive emotions associated with excitement or lack of arousal. Our data suggests that different positive emotions may be characterized by qualitatively distinct profiles of autonomic activation. Also, given the role of positive emotions in social affiliation, and particularly positive emotions associated with a quiescence motivational state, results are interpreted in light of theoretical accounts that highlight the importance of vagal regulation for social behavior. Copyright © 2017 Elsevier B.V. All rights reserved.
Influence of computer work under time pressure on cardiac activity.
Shi, Ping; Hu, Sijung; Yu, Hongliu
2015-03-01
Computer users are often under stress when required to complete computer work within a required time. Work stress has repeatedly been associated with an increased risk for cardiovascular disease. The present study examined the effects of time pressure workload during computer tasks on cardiac activity in 20 healthy subjects. Heart rate, time domain and frequency domain indices of heart rate variability (HRV) and Poincaré plot parameters were compared among five computer tasks and two rest periods. Faster heart rate and decreased standard deviation of R-R interval were noted in response to computer tasks under time pressure. The Poincaré plot parameters showed significant differences between different levels of time pressure workload during computer tasks, and between computer tasks and the rest periods. In contrast, no significant differences were identified for the frequency domain indices of HRV. The results suggest that the quantitative Poincaré plot analysis used in this study was able to reveal the intrinsic nonlinear nature of the autonomically regulated cardiac rhythm. Specifically, heightened vagal tone occurred during the relaxation computer tasks without time pressure. In contrast, the stressful computer tasks with added time pressure stimulated cardiac sympathetic activity. Copyright © 2015 Elsevier Ltd. All rights reserved.
Heart rate variability (HRV) analysis in radio and TV broadcasting stations workers.
Bortkiewicz, Alicja; Gadzicka, Elżbieta; Szymczak, Wiesław; Zmyślony, Marek
2012-09-01
The aim of the study was to assess the mechanism of cardiovascular impairments in workers exposed to UHF-VHF radio frequency electromagnetic fields (EMF). Heart rate variability (HRV) was analysed using 512 normal heart beats registered at rest. The analysis concerned time-domain (STD R-R) and frequency-domain (VLF, LF, HF) parameters of HRV. Fifty nine workers (group I) with low-level and 12 workers (group II) with high-level exposure were examined. The mean age of the subjects was 47 ± 9 years and 41 ± 14 years, and mean exposure duration 19.1 ± 8.8 years and 13 ± 4 years, in groups I and II, respectively. The groups were divided according to: E(max), E(dose), E(mean) for frequencies UHF, VHF and UHF+VHF: The control group consisted of 42 non-exposed subjects, aged 49 ± 8 years. Statistical analysis comprised one-way analysis of variance, covariance analysis and logistic regression models. In the exposed groups, the heart rate was higher than in the control one. Standard deviation of R-R intervals (STD R-R) was found to be significantly (p = 0.0285) lower in group I (42.5 ± 24.7 ms) compared to the control group (62.9 ± 53.5 ms). The risk of lowered STD R-R was significantly increased (OR = 2.37, p = 0.023) in group II. Both exposed groups presented significantly higher VLF and LF values than the control group (p = 0.005 and p = 0.0025, respectively). The EMF-exposed groups were characterised by the dominance of the sympathetic system (LF/HF 1.3 ± 0.35). The results indicate that exposure to radiofrequency EMF may affect the neurovegetative regulation.
Kim, Hayeon Jennifer; Yang, Jaewon; Lee, Moon Soo
2015-09-01
The aim of this study was to clarify the relationship between the autonomic nervous system and attention deficit hyperactivity disorder (ADHD) rating scales and to evaluate the usefulness of heart rate variability (HRV) as a psychophysiological biomarker for ADHD. Subjects were recruited from outpatients in the Department of Child and Adolescent Psychiatry at the Korea University Medical Center from August 2007 to December 2010. Subjects received methylphenidate. Time- and frequency-domain analyses of HRV, the Korean ADHD rating scale (K-ARS), and computerized ADHD diagnostic system were evaluated before treatment. After a 12-week period of medication administration, we repeated the HRV measurements and K-ARS rating. Eighty-six subjects were initially enrolled and 37 participants completed the 12-week treatment and HRV measurements subsequent to the treatment. Significant correlations were found between the K-ARS inattention score and some HRV parameters. All of the HRV parameters, except the standard deviations of the normal-to-normal interval, very low frequency, and low frequency to high frequency, showed a significant positive correlation between baseline and endpoint measures in completers. High frequency (HF) and the square root of the mean squared differences of successive normal-to-normal intervals (RMSSD), which are related to parasympathetic vagal tone, showed significant decreases from baseline to endpoint. The HRV test was shown to be reproducible. The decrease in HF and RMSSD suggests that parasympathetic dominance in ADHD can be altered by methylphenidate treatment. It also shows the possibility that HRV parameters can be used as psychophysiological markers in the treatment of ADHD.
Nearing, Bruce D; Libbus, Imad; Amurthur, Badri; Kenknight, Bruce H; Verrier, Richard L
2016-09-01
Chronic vagus nerve stimulation (VNS) applied to produce biomimetic levels of parasympathetic activation is feasible, well tolerated, safe, improves left ventricular ejection fraction, NYHA class, heart rate variability, and baroreflex function, and reduces T-wave alternans (TWA) in patients with chronic heart failure. However, the acute effects of VNS on beat-to-beat heart rate dynamics have not been systematically characterized in humans. We evaluated acute effects of VNS on R-R-interval dynamics during the VNS titration period in patients (n = 59) enrolled in ANTHEM-HF trial by quantifying effects during continuous cyclic VNS (14-seconds on-time, 66-seconds off-time) adjusted to the maximum tolerable dose without excessive (<4 bpm) bradycardia during the 10-week titration period. VNS elicited an immediate change in heart rate that was correlated to VNS current amplitude, pulse width, and frequency. Heart rate decreased more in the 28 patients with right-sided stimulation (-2.22 ± 0.13 bpm) than in the 31 patients with left-sided stimulation (-0.60 ± 0.08 bpm, P < 0.001). The linear correlation between stimulus intensity and lengthening of the R-R interval was stronger among the 28 patients with right-sided VNS implantation (r = 0.88, P < 0.0001) than among the 31 patients with left-sided VNS implantation (r = 0.49, P < 0.002). In all patients, the heart rate change elicited by VNS was significantly greater than the change during the same timing intervals in 10 randomly selected patients without stimulation (+0.08 ± 0.06 bpm, P < 0.001). Instantaneous heart rate change during therapeutic levels of VNS in patients with heart failure indicates consistent modulation of the autonomic nervous system for both left- and right-sided stimulation. © 2016 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.
Ruffini, Nuria; D'Alessandro, Giandomenico; Mariani, Nicolò; Pollastrelli, Alberto; Cardinali, Lucia; Cerritelli, Francesco
2015-01-01
Heart Rate Variability (HRV) indicates how heart rate changes in response to inner and external stimuli. HRV is linked to health status and it is an indirect marker of the autonomic nervous system (ANS) function. To investigate the influence of osteopathic manipulative treatment (OMT) on cardiac autonomic modulation in healthy subjects, compared with sham therapy and control group. Sixty-six healthy subjects, both male and female, were included in the present 3-armed randomized placebo controlled within subject cross-over single blinded study. Participants were asymptomatic adults (26.7 ± 8.4 y, 51% male, BMI 18.5 ± 4.8), both smokers and non-smokers and not on medications. At enrollment subjects were randomized in three groups: A, B, C. Standardized structural evaluation followed by a patient need-based osteopathic treatment was performed in the first session of group A and in the second session of group B. Standardized evaluation followed by a protocoled sham treatment was provided in the second session of group A and in the first session of group B. No intervention was performed in the two sessions of group C, acting as a time-control. The trial was registered on clinicaltrials.gov identifier: NCT01908920. HRV was calculated from electrocardiography before, during and after the intervention, for a total amount time of 25 min and considering frequency domain as well as linear and non-linear methods as outcome measures. OMT engendered a statistically significant increase of parasympathetic activity, as shown by High Frequency power (p < 0.001), expressed in normalized and absolute unit, and possibly decrease of sympathetic activity, as revealed by Low Frequency power (p < 0.01); results also showed a reduction of Low Frequency/High Frequency ratio (p < 0.001) and Detrended fluctuation scaling exponent (p < 0.05). Findings suggested that OMT can influence ANS activity increasing parasympathetic function and decreasing sympathetic activity, compared to sham therapy and control group.
Binaural Beat: A Failure to Enhance EEG Power and Emotional Arousal
López-Caballero, Fran; Escera, Carles
2017-01-01
When two pure tones of slightly different frequencies are delivered simultaneously to the two ears, is generated a beat whose frequency corresponds to the frequency difference between them. That beat is known as acoustic beat. If these two tones are presented one to each ear, they still produce the sensation of the same beat, although no physical combination of the tones occurs outside the auditory system. This phenomenon is called binaural beat. In the present study, we explored the potential contribution of binaural beats to the enhancement of specific electroencephalographic (EEG) bands, as previous studies suggest the potential usefulness of binaural beats as a brainwave entrainment tool. Additionally, we analyzed the effects of binaural-beat stimulation on two psychophysiological measures related to emotional arousal: heart rate and skin conductance. Beats of five different frequencies (4.53 Hz -theta-, 8.97 Hz -alpha-, 17.93 Hz -beta-, 34.49 Hz -gamma- or 57.3 Hz -upper-gamma) were presented binaurally and acoustically for epochs of 3 min (Beat epochs), preceded and followed by pink noise epochs of 90 s (Baseline and Post epochs, respectively). In each of these epochs, we analyzed the EEG spectral power, as well as calculated the heart rate and skin conductance response (SCR). For all the beat frequencies used for stimulation, no significant changes between Baseline and Beat epochs were observed within the corresponding EEG bands, neither with binaural or with acoustic beats. Additional analysis of spectral EEG topographies yielded negative results for the effect of binaural beats in the scalp distribution of EEG spectral power. In the psychophysiological measures, no changes in heart rate and skin conductance were observed for any of the beat frequencies presented. Our results do not support binaural-beat stimulation as a potential tool for the enhancement of EEG oscillatory activity, nor to induce changes in emotional arousal. PMID:29187819
Binaural Beat: A Failure to Enhance EEG Power and Emotional Arousal.
López-Caballero, Fran; Escera, Carles
2017-01-01
When two pure tones of slightly different frequencies are delivered simultaneously to the two ears, is generated a beat whose frequency corresponds to the frequency difference between them. That beat is known as acoustic beat. If these two tones are presented one to each ear, they still produce the sensation of the same beat, although no physical combination of the tones occurs outside the auditory system. This phenomenon is called binaural beat. In the present study, we explored the potential contribution of binaural beats to the enhancement of specific electroencephalographic (EEG) bands, as previous studies suggest the potential usefulness of binaural beats as a brainwave entrainment tool. Additionally, we analyzed the effects of binaural-beat stimulation on two psychophysiological measures related to emotional arousal: heart rate and skin conductance. Beats of five different frequencies (4.53 Hz -theta-, 8.97 Hz -alpha-, 17.93 Hz -beta-, 34.49 Hz -gamma- or 57.3 Hz -upper-gamma) were presented binaurally and acoustically for epochs of 3 min (Beat epochs), preceded and followed by pink noise epochs of 90 s (Baseline and Post epochs, respectively). In each of these epochs, we analyzed the EEG spectral power, as well as calculated the heart rate and skin conductance response (SCR). For all the beat frequencies used for stimulation, no significant changes between Baseline and Beat epochs were observed within the corresponding EEG bands, neither with binaural or with acoustic beats. Additional analysis of spectral EEG topographies yielded negative results for the effect of binaural beats in the scalp distribution of EEG spectral power. In the psychophysiological measures, no changes in heart rate and skin conductance were observed for any of the beat frequencies presented. Our results do not support binaural-beat stimulation as a potential tool for the enhancement of EEG oscillatory activity, nor to induce changes in emotional arousal.
Dural, Muhammet; Kabakcı, Giray; Cınar, Neşe; Erbaş, Tomris; Canpolat, Uğur; Gürses, Kadri Murat; Tokgözoğlu, Lale; Oto, Ali; Kaya, Ergün Barış; Yorgun, Hikmet; Sahiner, Levent; Dağdelen, Selçuk; Aytemir, Kudret
2014-04-01
Cardiovascular complications are the most common causes of morbidity and mortality in acromegaly. However, there is little data regarding cardiac autonomic functions in these patients. Herein, we aimed to investigate several parameters of cardiac autonomic functions in patients with acromegaly compared to healthy subjects. We enrolled 20 newly diagnosed acromegalic patients (55% female, age:45.7 ± 12.6 years) and 32 age- and gender-matched healthy subjects. All participants underwent 24 h Holter recording. Heart rate recovery (HRR) indices were calculated by subtracting 1st, 2nd and 3rd minute heart rates from maximal heart rate. All patients underwent heart rate variability (HRV) and QT dynamicity analysis. Baseline characteristics were similar except diabetes mellitus and hypertension among groups. Mean HRR1 (29.2 ± 12.3 vs 42.6 ± 6.5, p = 0.001), HRR2 (43.5 ± 15.6 vs 61.1 ± 10.8, p = 0.001) and HRR3 (46.4 ± 16.2 vs 65.8 ± 9.8, p = 0.001) values were significantly higher in control group. HRV parameters as, SDNN [standard deviation of all NN intervals] (p = 0.001), SDANN [SD of the 5 min mean RR intervals] (p = 0.001), RMSSD [root square of successive differences in RR interval] (p = 0.001), PNN50 [proportion of differences in successive NN intervals >50 ms] (p = 0.001) and high-frequency [HF] (p = 0.001) were significantly decreased in patients with acromegaly; but low frequency [LF] (p = 0.046) and LF/HF (p = 0.001) were significantly higher in acromegaly patients. QTec (p = 0.009), QTac/RR slope (p = 0.017) and QTec/RR slope (p = 0.01) were significantly higher in patients with acromegaly. Additionally, there were significant negative correlation of disease duration with HRR2, HRR3, SDNN, PNN50, RMSSD, variability index. Our study results suggest that cardiac autonomic functions are impaired in patients with acromegaly. Further large scale studies are needed to exhibit the prognostic significance of impaired autonomic functions in patients with acromegaly.
Kovács, Levente; Kézér, Fruzsina Luca; Ruff, Ferenc; Szenci, Ottó
2016-03-01
This investigation was conducted to examine circadian and seasonal rhythms of heart rate and heart rate variability (HRV) by means of hour-by-hour recordings over 24h in a large population of non-lactating Holstein-Friesian pregnant cows [N=56, summer (June-July); N=61, winter (November-December)]. Data were collected during a 5-day period from each animal. Besides parameters of cardiac autonomic function [the high-frequency (HF) component of HRV and the ratio between the low-frequency (LF) and the HF components (LF/HF ratio)], the RR triangular index and Lmax were calculated. A clear circadian profile was observed for every parameter in summer. Heart rate elevated gradually with the course of the day from 7:00 to 17:00 o'clock and then slightly decreased from 18:00 to 6:00. Sympathovagal balance shifted towards sympathetic dominance during the daytime (increased LF/HF ratio), whereas parasympathetic activity was predominant during the night (increased HF). Lmax reflected a chaotic behavior of heart rate fluctuations during the afternoon in summer. Decreased values of RR triangular index indicated a sensitive period for cows between 14:00 and 16:00 o'clock in summer. During winter, except for the RR triangular (RRtri) index reflecting a high overall variability in R-R intervals between 12:00 and 23:00 o'clock, heart rate and HRV showed no periodicity over the 24-h period. The results suggest an impaired cardiac autonomic function during daytime in summer. HF, Lmax and RRtri index showed seasonal differences for both daytime and nighttime. Heart rate was higher in summer than in winter during the daytime, whereas the LF/HF ratio was higher in winter during the nighttime. Circadian and seasonal rhythms of cardiovascular function are presumably related to the differing temperature, and animal activity associated with summer and winter. As all of the investigated parameters are commonly used in bovine HRV research, these findings have practical implications for behavioral, physiological and welfare studies on dairy cattle. Copyright © 2015 Elsevier Inc. All rights reserved.
Cho, Yoon Hi; Craig, Maria E; Davis, Elizabeth A; Cotterill, Andrew M; Couper, Jennifer J; Cameron, Fergus J; Benitez-Aguirre, Paul Z; Dalton, R Neil; Dunger, David B; Jones, Timothy W; Donaghue, Kim C
2015-04-01
This study examined the association between cardiac autonomic dysfunction and high albumin-to-creatinine ratio (ACR) in adolescents with type 1 diabetes. Adolescents recruited as part of a multicenter screening study (n = 445, 49% female, aged 10-17 years, mean duration 6.9 years; mean HbA1c 8.4%, 68 mmol/mol) underwent a 10-min continuous electrocardiogram recording for heart rate variability analysis. Time-domain heart rate variability measures included baseline heart rate, SD of the R-R interval (SDNN), and root mean squared difference of successive R-R intervals (RMSSD). Spectral analysis included sympathetic (low-frequency) and parasympathetic (high-frequency) components. Standardized ACR were calculated from six early morning urine collections using an established algorithm, reflecting age, sex, and duration, and stratified into ACR tertiles, where the upper tertile reflects higher nephropathy risk. The upper-tertile ACR group had a faster heart rate (76 vs. 73 bpm; P < 0.01) and less heart rate variability (SDNN 68 vs. 76 ms, P = 0.02; RMSSD 63 vs. 71 ms, P = 0.04). HbA1c was 8.5% (69 mmol/mmol) in the upper tertile vs. 8.3% (67 mmol/mol) in the lower tertiles (P = 0.07). In multivariable analysis, upper-tertile ACR was associated with faster heart rate (β = 2.5, 95% CI 0.2-4.8, P = 0.03) and lower RMSSD (β = -9.5, 95% CI -18.2 to -0.8, P = 0.03), independent of age and HbA1c. Adolescents at potentially higher risk for nephropathy show an adverse cardiac autonomic profile, indicating sympathetic overdrive, compared with the lower-risk group. Longitudinal follow-up of this cohort will further characterize the relationship between autonomic and renal dysfunction and the effect of interventions in this population. © 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.
Search for correlation between geomagnetic disturbances and mortality
NASA Technical Reports Server (NTRS)
Lipa, B. J.; Barnes, C. W.; Sturrock, P. A.; Feinleib, M.; Rogot, E.
1975-01-01
Statistical evaluation of death rates in the U.S.A. from heart diseases or stroke did not show any correlation with measured geomagnetic pulsations and thus do not support a claimed relationship between geomagnetic activity and mortality rates to low frequency fluctuations of the earth's magnetic field.
Al-Shargabi, T; Govindan, R B; Dave, R; Metzler, M; Wang, Y; du Plessis, A; Massaro, A N
2017-06-01
To determine whether systemic inflammation-modulating cytokine expression is related to heart rate variability (HRV) in newborns with hypoxic-ischemic encephalopathy (HIE). The data from 30 newborns with HIE were analyzed. Cytokine levels (IL-2, IL-4, IL-6, IL-8, IL-10, IL-13, IL-1β, TNF-α, IFN-λ) were measured either at 24 h of cooling (n=5), 72 h of cooling (n=4) or at both timepoints (n=21). The following HRV metrics were quantified in the time domain: alpha_S, alpha_L, root mean square (RMS) at short time scales (RMS_S), RMS at long time scales (RMS_L), while low-frequency power (LF) and high-frequency power (HF) were quantified in the frequency domain. The relationships between HRV metrics and cytokines were evaluated using mixed-models. IL-6, IL-8, IL-10, and IL-13 levels were inversely related to selected HRV metrics. Inflammation-modulating cytokines may be important mediators in the autonomic dysfunction observed in newborns with HIE.
Ambulatory ECG and analysis of heart rate variability in Parkinson's disease.
Haapaniemi, T H; Pursiainen, V; Korpelainen, J T; Huikuri, H V; Sotaniemi, K A; Myllylä, V V
2001-03-01
Cardiovascular reflex tests have shown both sympathetic and parasympathetic failure in Parkinson's disease. These tests, however, describe the autonomic responses during a restricted time period and have great individual variability, providing a limited view of the autonomic cardiac control mechanisms. Thus, they do not reflect tonic autonomic regulation. The aim was to examine tonic autonomic cardiovascular regulation in untreated patients with Parkinson's disease. 24 Hour ambulatory ECG was recorded in 54 untreated patients with Parkinson's disease and 47 age matched healthy subjects. In addition to the traditional spectral (very low frequency, VLF; low frequency, LF; high frequency, HF) and non-spectral components of heart rate variability, instantaneous beat to beat variability (SD1) and long term continuous variability (SD2) derived from Poincaré plots, and the slope of the power law relation were analysed. All spectral components (p<0.01) and the slope of the power-law relation (p<0.01) were lower in the patients with Parkinson's disease than in the control subjects. The Unified Parkinson's disease rating scale total and motor scores had a negative correlation with VLF and LF power spectrum values and the power law relation slopes. Patients with mild hypokinesia had higher HF values than patients with more severe hypokinesia. Tremor and rigidity were not associated with the HR variability parameters. Parkinson's disease causes dysfunction of the diurnal autonomic cardiovascular regulation as demonstrated by the spectral measures of heart rate variability and the slope of the power law relation. This dysfunction seems to be more profound in patients with more severe Parkinson's disease.
Matsunag, Daichi; Izumi, Shintaro; Okuno, Keisuke; Kawaguchi, Hiroshi; Yoshimoto, Masahiko
2015-01-01
This paper describes a non-contact and noise-tolerant heart beat monitoring system. The proposed system comprises a microwave Doppler sensor and range imagery using Microsoft Kinect™. The possible application of the proposed system is a driver health monitoring. We introduce the sensor fusion approach to minimize the heart beat detection error. The proposed algorithm can subtract a body motion artifact from Doppler sensor output using time-frequency analysis. The body motion artifact is a crucially important problem for biosignal monitoring using microwave Doppler sensor. The body motion speed is obtainable from range imagery, which has 5-mm resolution at 30-cm distance. Measurement results show that the success rate of the heart beat detection is improved about 75% on average when the Doppler wave is degraded by the body motion artifact.
Gross, Mike J; Shearer, David A; Bringer, Joy D; Hall, Ross; Cook, Christian J; Kilduff, Liam P
2016-09-01
Support and management staff in elite sport experience work-related stress and emotional disturbance to a similar extent as athletes (Fletcher and Wagstaff 2009). The resonant frequency breathing technique (Lehrer et al. 2000) can inhibit autonomic changes associated with stressful situations or events and as such provides a potential emotional regulation tool. The present study utilised five practitioner-led heart rate variability (HRV) biofeedback sessions and home practice via mobile applications to train support and management staff (n = 9) in resonant frequency breathing techniques. Although baseline HRV did not change from pre to post training, participants increased total HRV (i.e., SDNN; p = .006), parasympathetic HRV (i.e., RMSSD; p = .028) and HRV reflective of baroreflex function (i.e., low frequency power; p = .018) while accurately performing resonant frequency breathing without a breath pacer. Post-intervention questionnaire data revealed an increase (p = .032) in habitual use of somatic strategies for emotional regulation, and social validation data suggested that the technique enhanced emotional regulation at home, work and during international competition. HRV biofeedback and the resonant frequency technique provided an on-demand emotional regulation technique for elite sport support and management staff.
Cheng, Tzu-Han; Tsai, Chen-Gia
2016-01-01
Although music and the emotion it conveys unfold over time, little is known about how listeners respond to shifts in musical emotions. A special technique in heavy metal music utilizes dramatic shifts between loud and soft passages. Loud passages are penetrated by distorted sounds conveying aggression, whereas soft passages are often characterized by a clean, calm singing voice and light accompaniment. The present study used heavy metal songs and soft sea sounds to examine how female listeners’ respiration rates and heart rates responded to the arousal changes associated with auditory stimuli. The high-frequency power of heart rate variability (HF-HRV) was used to assess cardiac parasympathetic activity. The results showed that the soft passages of heavy metal songs and soft sea sounds expressed lower arousal and induced significantly higher HF-HRVs than the loud passages of heavy metal songs. Listeners’ respiration rate was determined by the arousal level of the present music passage, whereas the heart rate was dependent on both the present and preceding passages. Compared with soft sea sounds, the loud music passage led to greater deceleration of the heart rate at the beginning of the following soft music passage. The sea sounds delayed the heart rate acceleration evoked by the following loud music passage. The data provide evidence that sound-induced parasympathetic activity affects listeners’ heart rate in response to the following music passage. These findings have potential implications for future research on the temporal dynamics of musical emotions. PMID:26925009
Ketelhut, R G
1998-12-10
Physical activity in the form of endurance training is highly recommendable for hypertensives. Both suitable and unsuitable forms of sports are identified. From various points of view, two one-hour sessions per week would appear to be optimal. The intensity of the activity should be oriented to the heart rate, and, for safety's sake, prior ergometric evaluation should be carried out. As a rule of thumb, the heart rate should not exceed 70% of the maximum rate during exercise. If the blood pressure should nevertheless increase too much, appropriate pharmacological treatment is indicated.
Nunn, Nicolas; Feetham, Claire H; Martin, Jennifer; Barrett-Jolley, Richard; Plagge, Antonius
2013-10-01
Imbalances of energy homeostasis are often associated with cardiovascular complications. Previous work has shown that Gnasxl-deficient mice have a lean and hypermetabolic phenotype, with increased sympathetic stimulation of adipose tissue. The Gnasxl transcript from the imprinted Gnas locus encodes the trimeric G-protein subunit XLαs, which is expressed in brain regions that regulate energy homeostasis and sympathetic nervous system (SNS) activity. To determine whether Gnasxl knock-out (KO) mice display additional SNS-related phenotypes, we have now investigated the cardiovascular system. The Gnasxl KO mice were ∼20 mmHg hypertensive in comparison to wild-type (WT) littermates (P ≤ 0.05) and hypersensitive to the sympatholytic drug reserpine. Using telemetry, we detected an increased waking heart rate in conscious KOs (630 ± 10 versus 584 ± 12 beats min(-1), KO versus WT, P ≤ 0.05). Body temperature was also elevated (38.1 ± 0.3 versus 36.9 ± 0.4°C, KO versus WT, P ≤ 0.05). To investigate autonomic nervous system influences, we used heart rate variability analyses. We empirically defined frequency power bands using atropine and reserpine and verified high-frequency (HF) power and low-frequency (LF) LF/HF power ratio to be indicators of parasympathetic and sympathetic activity, respectively. The LF/HF power ratio was greater in KOs and more sensitive to reserpine than in WTs, consistent with elevated SNS activity. In contrast, atropine and exendin-4, a centrally acting agonist of the glucagon-like peptide-1 receptor, which influences cardiovascular physiology and metabolism, reduced HF power equally in both genotypes. This was associated with a greater increase in heart rate in KOs. Mild stress had a blunted effect on the LF/HF ratio in KOs consistent with elevated basal sympathetic activity. We conclude that XLαs is required for the inhibition of sympathetic outflow towards cardiovascular and metabolically relevant tissues.
Santaella, Danilo F; Devesa, Cesar R S; Rojo, Marcos R; Amato, Marcelo B P; Drager, Luciano F; Casali, Karina R; Montano, Nicola
2011-01-01
Objectives Since ageing is associated with a decline in pulmonary function, heart rate variability and spontaneous baroreflex, and recent studies suggest that yoga respiratory exercises may improve respiratory and cardiovascular function, we hypothesised that yoga respiratory training may improve respiratory function and cardiac autonomic modulation in healthy elderly subjects. Design 76 healthy elderly subjects were enrolled in a randomised control trial in Brazil and 29 completed the study (age 68±6 years, 34% males, body mass index 25±3 kg/m2). Subjects were randomised into a 4-month training program (2 classes/week plus home exercises) of either stretching (control, n=14) or respiratory exercises (yoga, n=15). Yoga respiratory exercises (Bhastrika) consisted of rapid forced expirations followed by inspiration through the right nostril, inspiratory apnoea with generation of intrathoracic negative pressure, and expiration through the left nostril. Pulmonary function, maximum expiratory and inspiratory pressures (PEmax and PImax, respectively), heart rate variability and blood pressure variability for spontaneous baroreflex determination were determined at baseline and after 4 months. Results Subjects in both groups had similar demographic parameters. Physiological variables did not change after 4 months in the control group. However, in the yoga group, there were significant increases in PEmax (34%, p<0.0001) and PImax (26%, p<0.0001) and a significant decrease in the low frequency component (a marker of cardiac sympathetic modulation) and low frequency/high frequency ratio (marker of sympathovagal balance) of heart rate variability (40%, p<0.001). Spontaneous baroreflex did not change, and quality of life only marginally increased in the yoga group. Conclusion Respiratory yoga training may be beneficial for the elderly healthy population by improving respiratory function and sympathovagal balance. Trial Registration CinicalTrials.gov identifier: NCT00969345; trial registry name: Effects of respiratory yoga training (Bhastrika) on heart rate variability and baroreflex, and quality of life of healthy elderly subjects. PMID:22021757
Mather, Mara; Joo Yoo, Hyun; Clewett, David V; Lee, Tae-Ho; Greening, Steven G; Ponzio, Allison; Min, Jungwon; Thayer, Julian F
2017-04-15
The locus coeruleus (LC) is a key node of the sympathetic nervous system and suppresses parasympathetic activity that would otherwise increase heart rate variability. In the current study, we examined whether LC-MRI contrast reflecting neuromelanin accumulation in the LC was associated with high-frequency heart rate variability (HF-HRV), a measure reflecting parasympathetic influences on the heart. Recent evidence indicates that neuromelanin, a byproduct of catecholamine metabolism, accumulates in the LC through young and mid adulthood, suggesting that LC-MRI contrast may be a useful biomarker of individual differences in habitual LC activation. We found that, across younger and older adults, greater LC-MRI contrast was negatively associated with HF-HRV during fear conditioning and spatial detection tasks. This correlation was not accounted for by individual differences in age or anxiety. These findings indicate that individual differences in LC structure relate to key cardiovascular parameters. Copyright © 2017 Elsevier Inc. All rights reserved.
Kaneko, Soichiro; Watanabe, Masashi; Takayama, Shin; Numata, Takehiro; Seki, Takashi; Tanaka, Junichi; Kanemura, Seiki; Kagaya, Yutaka; Ishii, Tadashi; Kimura, Yoshitaka; Yaegashi, Nobuo
2013-01-01
Objective. We investigated the relationship between superior mesenteric artery blood flow volume (SMA BFV) and autonomic nerve activity in acupuncture stimulation of lower limb points through heart rate variability (HRV) evaluations. Methods. Twenty-six healthy volunteers underwent crossover applications of bilateral manual acupuncture stimulation at ST36 or LR3 or no stimulation. Heart rate, blood pressure, cardiac index, systemic vascular resistance index, SMA BFV, and HRV at rest and 30 min after the intervention were analyzed. Results. SMA BFV showed a significant increase after ST36 stimulation (0% to 14.1% ± 23.4%, P = 0.007); very low frequency (VLF), high frequency (HF), low frequency (LF), and LF/HF were significantly greater than those at rest (0% to 479.4% ± 1185.6%, P = 0.045; 0% to 78.9% ± 197.6%, P = 0.048; 0% to 123.9% ± 217.1%, P = 0.006; 0% to 71.5% ± 171.1%, P = 0.039). Changes in HF and LF also differed significantly from those resulting from LR3 stimulation (HF: 78.9% ± 197.6% versus -18.2% ± 35.8%, P = 0.015; LF: 123.9% ± 217.1% versus 10.6% ± 70.6%, P = 0.013). Conclusion. Increased vagus nerve activity after ST36 stimulation resulted in increased SMA BFV. This partly explains the mechanism of acupuncture-induced BFV changes.
Watanabe, Masashi; Tanaka, Junichi; Kanemura, Seiki; Kagaya, Yutaka; Ishii, Tadashi; Kimura, Yoshitaka; Yaegashi, Nobuo
2013-01-01
Objective. We investigated the relationship between superior mesenteric artery blood flow volume (SMA BFV) and autonomic nerve activity in acupuncture stimulation of lower limb points through heart rate variability (HRV) evaluations. Methods. Twenty-six healthy volunteers underwent crossover applications of bilateral manual acupuncture stimulation at ST36 or LR3 or no stimulation. Heart rate, blood pressure, cardiac index, systemic vascular resistance index, SMA BFV, and HRV at rest and 30 min after the intervention were analyzed. Results. SMA BFV showed a significant increase after ST36 stimulation (0% to 14.1% ± 23.4%, P = 0.007); very low frequency (VLF), high frequency (HF), low frequency (LF), and LF/HF were significantly greater than those at rest (0% to 479.4% ± 1185.6%, P = 0.045; 0% to 78.9% ± 197.6%, P = 0.048; 0% to 123.9% ± 217.1%, P = 0.006; 0% to 71.5% ± 171.1%, P = 0.039). Changes in HF and LF also differed significantly from those resulting from LR3 stimulation (HF: 78.9% ± 197.6% versus −18.2% ± 35.8%, P = 0.015; LF: 123.9% ± 217.1% versus 10.6% ± 70.6%, P = 0.013). Conclusion. Increased vagus nerve activity after ST36 stimulation resulted in increased SMA BFV. This partly explains the mechanism of acupuncture-induced BFV changes. PMID:24381632
Heart rate variability during sleep following the practice of cyclic meditation and supine rest.
Patra, Sanjib; Telles, Shirley
2010-06-01
Day time activities are known to influence the sleep on the following night. Cyclic meditation (CM) has recurring cycles. Previously, the low frequency (LF) power and the ratio between low frequency and high frequency (LF/HF ratio) of the heart rate variability (HRV) decreased during and after CM but not after a comparable period of supine rest (SR). In the present study, on thirty male volunteers, CM was practiced twice in the day and after this the HRV was recorded (1) while awake and (2) during 6 h of sleep (based on EEG, EMG and EGG recordings). This was similarly recorded for the night's sleep following the day time practice of SR. Participants were randomly assigned to the two sessions and all of them practiced both CM and SR on different days. During the night following day time CM practice there were the following changes; a decrease in heart rate, LF power (n.u.), LF/HF ratio, and an increase in the number of pairs of Normal to Normal RR intervals differing by more than 50 ms divided by total number of all NN intervals (pNN50) (P < 0.05, in all cases, comparing sleep following CM compared with sleep following SR). No change was seen on the night following SR. Hence yoga practice during the day appears to shift sympatho-vagal balance in favor of parasympathetic dominance during sleep on the following night.
Morokuma, S; Horimoto, N; Nakano, H
2001-08-01
It is well known that 1/f characteristics in power spectral patterns exist in various biological factors including heart rate variability. In the present study, we tried to elucidate the diurnal variation in spectral properties of eye movement and heart rate variability in the human fetus at term, via continuous 24-h observation of both these parameters. Studied were five uncomplicated fetuses at term. We observed eye movement and fetal heart rate (FHR) with real-time ultrasound and Doppler cardiotocograph, respectively, and analyzed the diurnal change in spectral properties, using the maximum entropy method. In four of five cases, the slope values of power spectra for both eye movement frequency and FHR, ranging approximately between 0.5 and 1.8, indicated diurnal variation, where the slopes tended to have high values during the day and low values at night. These findings suggest that, in the human fetus at term, eye movement and FHR are under the control of a common central mechanism, and this center changes its complexity as seen through diurnal rhythm.
NASA Technical Reports Server (NTRS)
Lund, G. F.; Westbrook, R. M.; Fryer, T. B.
1980-01-01
The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.
Heart rate variability: Pre-deployment predictor of post-deployment PTSD symptoms
Pyne, Jeffrey M.; Constans, Joseph I.; Wiederhold, Mark D.; Gibson, Douglas P.; Kimbrell, Timothy; Kramer, Teresa L.; Pitcock, Jeffery A.; Han, Xiaotong; Williams, D. Keith; Chartrand, Don; Gevirtz, Richard N.; Spira, James; Wiederhold, Brenda K.; McCraty, Rollin; McCune, Thomas R.
2017-01-01
Heart rate variability is a physiological measure associated with autonomic nervous system activity. This study hypothesized that lower pre-deployment HRV would be associated with higher post-deployment post-traumatic stress disorder (PTSD) symptoms. Three-hundred-forty-three Army National Guard soldiers enrolled in the Warriors Achieving Resilience (WAR) study were analyzed. The primary outcome was PTSD symptom severity using the PTSD Checklist – Military version (PCL) measured at baseline, 3- and 12-month post-deployment. Heart rate variability predictor variables included: high frequency power (HF) and standard deviation of the normal cardiac inter-beat interval (SDNN). Generalized linear mixed models revealed that the pre-deployment PCL*ln(HF) interaction term was significant (p < 0.0001). Pre-deployment SDNN was not a significant predictor of post-deployment PCL. Covariates included age, pre-deployment PCL, race/ethnicity, marital status, tobacco use, childhood abuse, pre-deployment traumatic brain injury, and previous combat zone deployment. Pre-deployment heart rate variability predicts post-deployment PTSD symptoms in the context of higher pre-deployment PCL scores. PMID:27773678
Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?
Mahdiani, Shadi; Jeyhani, Vala; Peltokangas, Mikko; Vehkaoja, Antti
2015-01-01
With the worldwide growth of mobile wireless technologies, healthcare services can be provided at anytime and anywhere. Usage of wearable wireless physiological monitoring system has been extensively increasing during the last decade. These mobile devices can continuously measure e.g. the heart activity and wirelessly transfer the data to the mobile phone of the patient. One of the significant restrictions for these devices is usage of energy, which leads to requiring low sampling rate. This article is presented in order to investigate the lowest adequate sampling frequency of ECG signal, for achieving accurate enough time domain heart rate variability (HRV) parameters. For this purpose the ECG signals originally measured with high 5 kHz sampling rate were down-sampled to simulate the measurement with lower sampling rate. Down-sampling loses information, decreases temporal accuracy, which was then restored by interpolating the signals to their original sampling rates. The HRV parameters obtained from the ECG signals with lower sampling rates were compared. The results represent that even when the sampling rate of ECG signal is equal to 50 Hz, the HRV parameters are almost accurate with a reasonable error.
Baek, Hyun Jae; Shin, JaeWook
2017-08-15
Most of the wrist-worn devices on the market provide a continuous heart rate measurement function using photoplethysmography, but have not yet provided a function to measure the continuous heart rate variability (HRV) using beat-to-beat pulse interval. The reason for such is the difficulty of measuring a continuous pulse interval during movement using a wearable device because of the nature of photoplethysmography, which is susceptible to motion noise. This study investigated the effect of missing heart beat interval data on the HRV analysis in cases where pulse interval cannot be measured because of movement noise. First, we performed simulations by randomly removing data from the RR interval of the electrocardiogram measured from 39 subjects and observed the changes of the relative and normalized errors for the HRV parameters according to the total length of the missing heart beat interval data. Second, we measured the pulse interval from 20 subjects using a wrist-worn device for 24 h and observed the error value for the missing pulse interval data caused by the movement during actual daily life. The experimental results showed that mean NN and RMSSD were the most robust for the missing heart beat interval data among all the parameters in the time and frequency domains. Most of the pulse interval data could not be obtained during daily life. In other words, the sample number was too small for spectral analysis because of the long missing duration. Therefore, the frequency domain parameters often could not be calculated, except for the sleep state with little motion. The errors of the HRV parameters were proportional to the missing data duration in the presence of missing heart beat interval data. Based on the results of this study, the maximum missing duration for acceptable errors for each parameter is recommended for use when the HRV analysis is performed on a wrist-worn device.
Langrish, Jeremy P; Li, Xi; Wang, Shengfeng; Lee, Matthew M Y; Barnes, Gareth D; Miller, Mark R; Cassee, Flemming R; Boon, Nicholas A; Donaldson, Ken; Li, Jing; Li, Liming; Mills, Nicholas L; Newby, David E; Jiang, Lixin
2012-03-01
Air pollution exposure increases cardiovascular morbidity and mortality and is a major global public health concern. We investigated the benefits of reducing personal exposure to urban air pollution in patients with coronary heart disease. In an open randomized crossover trial, 98 patients with coronary heart disease walked on a predefined route in central Beijing, China, under different conditions: once while using a highly efficient face mask, and once while not using the mask. Symptoms, exercise, personal air pollution exposure, blood pressure, heart rate, and 12-lead electrocardiography were monitored throughout the 24-hr study period. Ambient air pollutants were dominated by fine and ultrafine particulate matter (PM) that was present at high levels [74 μg/m³ for PM(2.5) (PM with aerodynamic diamater <2.5 µm)]. Consistent with traffic-derived sources, this PM contained organic carbon and polycyclic aromatic hydrocarbons and was highly oxidizing, generating large amounts of free radicals. The face mask was well tolerated, and its use was associated with decreased self-reported symptoms and reduced maximal ST segment depression (-142 vs. -156 μV, p = 0.046) over the 24-hr period. When the face mask was used during the prescribed walk, mean arterial pressure was lower (93 ± 10 vs. 96 ± 10 mmHg, p = 0.025) and heart rate variability increased (high-frequency power: 54 vs. 40 msec², p = 0.005; high-frequency normalized power: 23.5 vs. 20.5 msec, p = 0.001; root mean square successive differences: 16.7 vs. 14.8 msec, p = 0.007). However, mask use did not appear to influence heart rate or energy expenditure. Reducing personal exposure to air pollution using a highly efficient face mask appeared to reduce symptoms and improve a range of cardiovascular health measures in patients with coronary heart disease. Such interventions to reduce personal exposure to PM air pollution have the potential to reduce the incidence of cardiovascular events in this highly susceptible population.
Lee, Su Hyun; Lee, Dong Hoon; Ha, Dong Hoon; Oh, Young Jun
2015-10-08
Little is known about the changes in autonomic function during spinal anaesthesia in type 2 diabetic patients. The purpose of the study was to assess the influence of spinal anaesthesia on the heart rate variability in type 2 diabetic patients according to the glycated hemoglobin (HbA1c) level. Sixty-six patients who were scheduled for elective orthostatic lower limb surgery were assigned to three groups (n = 22, each) according to HbA1c; controlled diabetes mellitus (HbA1c < 7 %), uncontrolled diabetes mellitus (HbA1c > 7 %) and the control group. The heart rate variability was measured 10 min before (T0), and at10 min (T1), 20 min (T2) and 30 min (T3) after spinal anaesthesia. Before spinal anaesthesia, total, low-and high-frequency power were significantly lower in the uncontrolled diabetec group than in other group (p < 0.05). During spinal anaesthesia, total, low- and high-frequency powers were did not change in the uncontrolled diabetec group while the low-frequency power in the controlled diabetec group was significantly depressed (p < 0.05). The ratio of low-to high-frequency was comparable among the groups, while it was reduced at T1-2 than at T0 in all the groups. The blood pressures were higher in the uncontrolled diabetec group than in the other groups. Spinal anaesthesia had an influence on the cardiac autonomic modulation in controlled diabetec patients, but not in uncontrolled diabetec patients. There were no differences in all haemodynamic variables during an adequate level of spinal anaesthesia in controlled and uncontrolled type 2 DM. ClinicalTrials.gov NCT02137057.
Hsu, Chung-Chih; Liang, Chih-Sung; Tai, Yueh-Ming; Cheng, Shu-Li
2016-11-01
A bidirectional connection exists between obesity and altered heart rate variability (HRV). Schizophrenia has been associated with a high risk of obesity and decreased vagal modulation. Few studies have examined the link between obesity and HRV in patients with schizophrenia. The aim of this study was to investigate the effects of aerobic exercise on body weight and HRV, and if so, whether these effects could be sustained after discontinuation of exercise training. A total of 18 overweight patients with schizophrenia completed an 8-week moderate-intensity aerobic exercise program conducted twice weekly for 50min. Body weight and heart rate variability were measured at baseline, week 8, and 4weeks after discontinuation of exercise training. Compared with the control group (15 overweight patients with schizophrenia without exercise training), the exercise group had reduced 2.3kg at week 8. Furthermore, the exercise program increased the low frequency, high frequency, and low frequency plus high frequency of HRV. However, after discontinuation of the exercise program for 4weeks, the changes in body weight and the HRV parameters diverged. All of the HRV parameters returned to their baseline values, but no change was seen in the reduced body weight. This suggests that HRV analysis is a more sensitive tool to detect health conditions in patients with schizophrenia. Although exercise is an easy and effective way to prevent and improve health problems, mental health providers might have underestimated the benefits of exercise in daily clinical practice. A regular exercise program should be considered as an essential part of treatment strategies for patients with schizophrenia. Copyright © 2016 Elsevier B.V. All rights reserved.
Kilinc, Ozden; Cincin, Altug; Pehlivan, Aslihan; Midi, Ipek; Kepez, Alper; Agan, Kadriye
2016-01-01
Background and Purpose: Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Methods: Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Results: Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Conclusions: Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures. PMID:27390676
The effect of sham feeding on neurocardiac regulation in healthy human volunteers
Kamath, Markad V; Spaziani, Robert; Ullal, Sangeeta; Tougas, Gervais; Guzman, Juan C; Morillo, Carlos; Capogna, Joshua; Al-Bayati, Mohammed; Armstrong, David
2007-01-01
BACKGROUND: Distension and electrical stimuli in the esophagus alter heart rate variability (HRV) consistent with activation of vagal afferent and efferent pathways. Sham feeding stimulates gastric acid secretion by means of vagal efferent pathways. It is not known, however, whether activation of vagal efferent pathways is organ- or stimulus-specific. OBJECTIVE: To test the hypothesis that sham feeding increases the high frequency (HF) component of HRV, indicating increased neurocardiac vagal activity in association with the known, vagally mediated, increase in gastric acid secretion. METHODS: Continuous electrocardiography recordings were obtained in 12 healthy, semirecumbent subjects during consecutive 45 min baseline, 20 min sham feeding (standard hamburger meal) and 45 min recovery periods. The R-R intervals and beat-to-beat heart rate signal were determined from digitized electrocardiography recordings; power spectra were computed from the heart rate signal to determine sympathetic (low frequency [LF]) and vagal (HF) components of HRV. RESULTS: Heart rate increased during sham feeding (median 70.8 beats/min, 95% CI 66.0 to 77.6; P<0.001), compared with baseline (63.6, 95% CI 60.8 to 70.0) and returned to baseline levels within 45 min. Sham feeding increased the LF to HF area ratio (median: 1.55, 95% C.I 1.28 to 1.77; P<0.021, compared with baseline (1.29, 95% CI 1.05 to 1.46); this increase in LF to HF area ratio was associated with a decrease in the HF component of HRV. CONCLUSIONS: Sham feeding produces a reversible increase in heart rate that is attributable to a decrease in neurocardiac parasympathetic activity despite its known ability to increase vagally mediated gastric acid secretion. These findings suggest that concurrent changes in cardiac and gastric function are modulated independently by vagal efferent fibres and that vagally mediated changes in organ function are stimulus- and organ-specific. PMID:18026575
Guided imagery, anxiety, heart rate, and heart rate variability during centrifuge training.
Jing, Xiaolu; Wu, Ping; Liu, Fang; Wu, Bin; Miao, Danmin
2011-02-01
Centrifuge training is an important method of improving the hypergravity tolerance of pilots, cosmonauts, and Chinese astronauts. However, the concomitants of tension or anxiety often impede training. Guided imagery (GI), a mind-body relaxation technique, provides a behavioral and cognitive means whereby individuals are able to exert control over the focus of attention. This study aims to investigate the immediate effects of GI for reducing stress in centrifuge training. There were 12 healthy young men who were randomly assigned to a GI group or music group. We measured changes in heart rate during centrifuge training, in heart rate variability before and after centrifuge training, and also evaluated relaxation and anxiety in three phases: before intervention, after intervention, and following centrifuge training. The change in the pattern of anxiety was different in the two groups over the three phases. Anxiety (measured by State Anxiety Inventory) in the GI group changed from 31.7 +/- 5.9 to 26.8 +/- 2.6 and 27.8 +/- 4.1, whereas for the music group this changed from 32.2 +/- 7.6 to 31.2 +/- 8.3 and 26.8 +/- 6.8. During centrifuge training, the maximal HR for the GI group (101.2 +/- 8.8) was lower than that of the music group (123.0 +/- 19.1). In addition GI showed a decrease in low frequency (LF, 0.04-0.15 Hz) components and an increase in high frequency (HF, 0.15-0.4 Hz) components before and after centrifuge training. GI was capable of decreasing tension, anxiety, and sympathetic nervous system activity pre- or post-centrifugation.
Champeroux, P; Thireau, J; Judé, S; Laigot-Barbé, C; Maurin, A; Sola, M L; Fowler, J S L; Richard, S; Le Guennec, J Y
2015-01-01
Background and Purpose The present study was undertaken to investigate an effect of dofetilide, a potent arrhythmic blocker of the voltage-gated K+ channel, hERG, on cardiac autonomic control. Combined with effects on ardiomyocytes, these properties could influence its arrhythmic potency. Experimental Approach The short-term variability of beat-to-beat QT interval (STVQT), induced by dofetilide is a strong surrogate of Torsades de pointes liability. Involvement of autonomic modulation in STVQT was investigated in healthy cynomolgus monkeys and beagle dogs by power spectral analysis under conditions of autonomic blockade with hexamethonium. Key Results Increase in STVQT induced by dofetilide in monkeys and dogs was closely associated with an enhancement of endogenous heart rate and QT interval high-frequency (HF) oscillations. These effects were fully suppressed under conditions of autonomic blockade with hexamethonium. Ventricular arrhythmias, including Torsades de pointes in monkeys, were prevented in both species when HF oscillations were suppressed by autonomic blockade. Similar enhancements of heart rate HF oscillations were found in dogs with other hERG blockers described as causing Torsades de pointes in humans. Conclusions and Implications These results demonstrate for the first time that beat-to-beat ventricular repolarization variability and ventricular arrhythmias induced by dofetilide are dependent on endogenous HF autonomic oscillations in heart rate. When combined with evidence of hERG-blocking properties, enhancement of endogenous HF oscillations in heart rate could constitute an earlier and more sensitive biomarker than STVQT for Torsades de pointes liability, applicable to preclinical regulatory studies conducted in healthy animals. PMID:25625756
Hirokawa, Kumi; Ohira, Tetsuya; Nagayoshi, Mako; Kajiura, Mitsugu; Imano, Hironori; Kitamura, Akihiko; Kiyama, Masahiko; Okada, Takeo; Iso, Hiroyasu
2016-12-01
This study aimed to investigate the effects of occupational status and job stress factors on cardiovascular stress reactivity in Japanese workers. In this baseline assessment between 2001 and 2009 in Osaka, Japan, we examined 928 healthy Japanese employees (330 men, 598 women) from two occupational statuses: managers/professionals and general workers. A brief job stress questionnaire was used to evaluate job stress levels. Systolic and diastolic blood pressure (SBP, DBP), heart rate, heart rate variability (high-frequency [HF], low-frequency [LF], LF/HF], and peripheral blood flow were measured at rest and during two stressful tasks. Changes in stress reactivity were calculated as the difference between the measured variables during the tasks and the rest period. Men showed inverse associations between quantitative job overload and DBP, heart rate, and LF/HF, between physical demands and blood pressure (SBP, DBP), and between a poor physical environment and HF. Men also had positive associations between qualitative job overload and heart rate, and between physical demands and peripheral blood flow (all p < 0.05). Women showed inverse associations between qualitative job overload and SBP, and showed positive associations between qualitative job overload and peripheral blood flow, and between a poor physical environment and SBP (all p < 0.05). When stratified by occupational status, significant associations between job stress and changes in stress reactivity were observed in male managers/professionals and female general workers (p < 0.05). Job stress levels are associated with changes in cardiovascular stress reactivity in men and women. Occupational status may modify these associations.
Behavioral neurocardiac training in hypertension: a randomized, controlled trial.
Nolan, Robert P; Floras, John S; Harvey, Paula J; Kamath, Markad V; Picton, Peter E; Chessex, Caroline; Hiscock, Natalie; Powell, Jonathan; Catt, Michael; Hendrickx, Hilde; Talbot, Duncan; Chen, Maggie H
2010-04-01
It is not established whether behavioral interventions add benefit to pharmacological therapy for hypertension. We hypothesized that behavioral neurocardiac training (BNT) with heart rate variability biofeedback would reduce blood pressure further by modifying vagal heart rate modulation during reactivity and recovery from standardized cognitive tasks ("mental stress"). This randomized, controlled trial enrolled 65 patients with uncomplicated hypertension to BNT or active control (autogenic relaxation), with six 1-hour sessions over 2 months with home practice. Outcomes were analyzed with linear mixed models that adjusted for antihypertensive drugs. BNT reduced daytime and 24-hour systolic blood pressures (-2.4+/-0.9 mm Hg, P=0.009, and -2.1+/-0.9 mm Hg, P=0.03, respectively) and pulse pressures (-1.7+/-0.6 mm Hg, P=0.004, and -1.4+/-0.6 mm Hg, P=0.02, respectively). No effect was observed for controls (P>0.10 for all indices). BNT also increased RR-high-frequency power (0.15 to 0.40 Hz; P=0.01) and RR interval (P<0.001) during cognitive tasks. Among controls, high-frequency power was unchanged (P=0.29), and RR interval decreased (P=0.03). Neither intervention altered spontaneous baroreflex sensitivity (P>0.10). In contrast to relaxation therapy, BNT with heart rate variability biofeedback modestly lowers ambulatory blood pressure during wakefulness, and it augments tonic vagal heart rate modulation. It is unknown whether efficacy of this treatment can be improved with biofeedback of baroreflex gain. BNT, alone or as an adjunct to drug therapy, may represent a promising new intervention for hypertension.
Champeroux, P; Thireau, J; Judé, S; Laigot-Barbé, C; Maurin, A; Sola, M L; Fowler, J S L; Richard, S; Le Guennec, J Y
2015-06-01
The present study was undertaken to investigate an effect of dofetilide, a potent arrhythmic blocker of the voltage-gated K(+) channel, hERG, on cardiac autonomic control. Combined with effects on ardiomyocytes, these properties could influence its arrhythmic potency. The short-term variability of beat-to-beat QT interval (STVQT ), induced by dofetilide is a strong surrogate of Torsades de pointes liability. Involvement of autonomic modulation in STVQT was investigated in healthy cynomolgus monkeys and beagle dogs by power spectral analysis under conditions of autonomic blockade with hexamethonium. Increase in STVQT induced by dofetilide in monkeys and dogs was closely associated with an enhancement of endogenous heart rate and QT interval high-frequency (HF) oscillations. These effects were fully suppressed under conditions of autonomic blockade with hexamethonium. Ventricular arrhythmias, including Torsades de pointes in monkeys, were prevented in both species when HF oscillations were suppressed by autonomic blockade. Similar enhancements of heart rate HF oscillations were found in dogs with other hERG blockers described as causing Torsades de pointes in humans. These results demonstrate for the first time that beat-to-beat ventricular repolarization variability and ventricular arrhythmias induced by dofetilide are dependent on endogenous HF autonomic oscillations in heart rate. When combined with evidence of hERG-blocking properties, enhancement of endogenous HF oscillations in heart rate could constitute an earlier and more sensitive biomarker than STVQT for Torsades de pointes liability, applicable to preclinical regulatory studies conducted in healthy animals. © 2015 The British Pharmacological Society.
Bombardini, Tonino; Gemignani, Vincenzo; Bianchini, Elisabetta; Venneri, Lucia; Petersen, Christina; Pasanisi, Emilio; Pratali, Lorenza; Alonso-Rodriguez, David; Pianelli, Mascia; Faita, Francesco; Giannoni, Massimo; Arpesella, Giorgio; Picano, Eugenio
2008-01-01
A cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been recently validated. Second heart sound can be simultaneously recorded in order to quantify both systole and diastole duration. Aims 1- To assess the feasibility and extra-value of operator-independent, force sensor-based, diastolic time recording during stress. Methods We enrolled 161 patients referred for stress echocardiography (exercise 115, dipyridamole 40, pacing 6 patients). The sensor was fastened in the precordial region by a standard ECG electrode. The acceleration signal was converted into digital and recorded together with ECG signal. Both systolic and diastolic times were acquired continuously during stress and were displayed by plotting times vs. heart rate. Diastolic filling rate was calculated as echo-measured mitral filling volume/sensor-monitored diastolic time. Results Diastolic time decreased during stress more markedly than systolic time. At peak stress 62 of the 161 pts showed reversal of the systolic/diastolic ratio with the duration of systole longer than diastole. In the exercise group, at 100 bpm HR, systolic/diastolic time ratio was lower in the 17 controls (0.74 ± 0.12) than in patients (0.86 ± 0.10, p < 0.05 vs. controls). Diastolic filling rate increased from 101 ± 36 (rest) to 219 ± 92 ml/m2* s-1 at peak stress (p < 0.5 vs. rest). Conclusion Cardiological systolic and diastolic duration can be monitored during stress by using an acceleration force sensor. Simultaneous calculation of stroke volume allows monitoring diastolic filling rate. Stress-induced "systolic-diastolic mismatch" can be easily quantified and is associated to several cardiac diseases, possibly expanding the spectrum of information obtainable during stress. PMID:18426559
NASA Technical Reports Server (NTRS)
Pikkujamsa, S. M.; Makikallio, T. H.; Sourander, L. B.; Raiha, I. J.; Puukka, P.; Skytta, J.; Peng, C. K.; Goldberger, A. L.; Huikuri, H. V.
1999-01-01
BACKGROUND: New methods of R-R interval variability based on fractal scaling and nonlinear dynamics ("chaos theory") may give new insights into heart rate dynamics. The aims of this study were to (1) systematically characterize and quantify the effects of aging from early childhood to advanced age on 24-hour heart rate dynamics in healthy subjects; (2) compare age-related changes in conventional time- and frequency-domain measures with changes in newly derived measures based on fractal scaling and complexity (chaos) theory; and (3) further test the hypothesis that there is loss of complexity and altered fractal scaling of heart rate dynamics with advanced age. METHODS AND RESULTS: The relationship between age and cardiac interbeat (R-R) interval dynamics from childhood to senescence was studied in 114 healthy subjects (age range, 1 to 82 years) by measurement of the slope, beta, of the power-law regression line (log power-log frequency) of R-R interval variability (10(-4) to 10(-2) Hz), approximate entropy (ApEn), short-term (alpha(1)) and intermediate-term (alpha(2)) fractal scaling exponents obtained by detrended fluctuation analysis, and traditional time- and frequency-domain measures from 24-hour ECG recordings. Compared with young adults (<40 years old, n=29), children (<15 years old, n=27) showed similar complexity (ApEn) and fractal correlation properties (alpha(1), alpha(2), beta) of R-R interval dynamics despite lower spectral and time-domain measures. Progressive loss of complexity (decreased ApEn, r=-0.69, P<0.001) and alterations of long-term fractal-like heart rate behavior (increased alpha(2), r=0.63, decreased beta, r=-0.60, P<0.001 for both) were observed thereafter from middle age (40 to 60 years, n=29) to old age (>60 years, n=29). CONCLUSIONS: Cardiac interbeat interval dynamics change markedly from childhood to old age in healthy subjects. Children show complexity and fractal correlation properties of R-R interval time series comparable to those of young adults, despite lower overall heart rate variability. Healthy aging is associated with R-R interval dynamics showing higher regularity and altered fractal scaling consistent with a loss of complex variability.
Zhu, Yujie; Hanafy, Mohamed A; Killingsworth, Cheryl R; Walcott, Gregory P; Young, Martin E; Pogwizd, Steven M
2014-01-01
Patients with chronic heart failure (CHF) exhibit a morning surge in ventricular arrhythmias, but the underlying cause remains unknown. The aim of this study was to determine if heart rate dynamics, autonomic input (assessed by heart rate variability (HRV)) and nonlinear dynamics as well as their abnormal time-of-day-dependent oscillations in a newly developed arrhythmogenic canine heart failure model are associated with a morning surge in ventricular arrhythmias. CHF was induced in dogs by aortic insufficiency & aortic constriction, and assessed by echocardiography. Holter monitoring was performed to study time-of-day-dependent variation in ventricular arrhythmias (PVCs, VT), traditional HRV measures, and nonlinear dynamics (including detrended fluctuations analysis α1 and α2 (DFAα1 & DFAα2), correlation dimension (CD), and Shannon entropy (SE)) at baseline, as well as 240 days (240 d) and 720 days (720 d) following CHF induction. LV fractional shortening was decreased at both 240 d and 720 d. Both PVCs and VT increased with CHF duration and showed a morning rise (2.5-fold & 1.8-fold increase at 6 AM-noon vs midnight-6 AM) during CHF. The morning rise in HR at baseline was significantly attenuated by 52% with development of CHF (at both 240 d & 720 d). Morning rise in the ratio of low frequency to high frequency (LF/HF) HRV at baseline was markedly attenuated with CHF. DFAα1, DFAα2, CD and SE all decreased with CHF by 31, 17, 34 and 7%, respectively. Time-of-day-dependent variations in LF/HF, CD, DFA α1 and SE, observed at baseline, were lost during CHF. Thus in this new arrhythmogenic canine CHF model, attenuated morning HR rise, blunted autonomic oscillation, decreased cardiac chaos and complexity of heart rate, as well as aberrant time-of-day-dependent variations in many of these parameters were associated with a morning surge of ventricular arrhythmias.
Zhu, Yujie; Hanafy, Mohamed A.; Killingsworth, Cheryl R.; Walcott, Gregory P.; Young, Martin E.; Pogwizd, Steven M.
2014-01-01
Patients with chronic heart failure (CHF) exhibit a morning surge in ventricular arrhythmias, but the underlying cause remains unknown. The aim of this study was to determine if heart rate dynamics, autonomic input (assessed by heart rate variability (HRV)) and nonlinear dynamics as well as their abnormal time-of-day-dependent oscillations in a newly developed arrhythmogenic canine heart failure model are associated with a morning surge in ventricular arrhythmias. CHF was induced in dogs by aortic insufficiency & aortic constriction, and assessed by echocardiography. Holter monitoring was performed to study time-of-day-dependent variation in ventricular arrhythmias (PVCs, VT), traditional HRV measures, and nonlinear dynamics (including detrended fluctuations analysis α1 and α2 (DFAα1 & DFAα2), correlation dimension (CD), and Shannon entropy (SE)) at baseline, as well as 240 days (240d) and 720 days (720d) following CHF induction. LV fractional shortening was decreased at both 240d and 720d. Both PVCs and VT increased with CHF duration and showed a morning rise (2.5-fold & 1.8-fold increase at 6 AM-noon vs midnight-6 AM) during CHF. The morning rise in HR at baseline was significantly attenuated by 52% with development of CHF (at both 240d & 720d). Morning rise in the ratio of low frequency to high frequency (LF/HF) HRV at baseline was markedly attenuated with CHF. DFAα1, DFAα2, CD and SE all decreased with CHF by 31, 17, 34 and 7%, respectively. Time-of-day-dependent variations in LF/HF, CD, DFA α1 and SE, observed at baseline, were lost during CHF. Thus in this new arrhythmogenic canine CHF model, attenuated morning HR rise, blunted autonomic oscillation, decreased cardiac chaos and complexity of heart rate, as well as aberrant time-of-day-dependent variations in many of these parameters were associated with a morning surge of ventricular arrhythmias. PMID:25140699
Andrzejak, Ryszard; Poreba, Rafal; Poreba, Malgorzata; Derkacz, Arkadiusz; Skalik, Robert; Gac, Pawel; Beck, Boguslaw; Steinmetz-Beck, Aleksandra; Pilecki, Witold
2008-08-01
It is possible that electromagnetic field (EMF) generated by mobile phones (MP) may have an influence on the autonomic nervous system (ANS) and modulates the function of circulatory system. The aim of the study was to estimate the influence of the call with a mobile phone on heart rate variability (HRV) in young healthy people. The time and frequency domain HRV analyses were performed to assess the changes in sympathovagal balance in a group of 32 healthy students with normal electrocardiogram (ECG) and echocardiogram at rest. The frequency domain variables were computed: ultra low frequency (ULF) power, very low frequency (VLF) power, low frequency (LF) power, high frequency (HF) power and LF/HF ratio was determined. ECG Holter monitoring was recorded in standardized conditions: from 08:00 to 09:00 in the morning in a sitting position, within 20 min periods: before the telephone call (period I), during the call with use of mobile phone (period II), and after the telephone call (period III). During 20 min call with a mobile phone time domain parameters such as standard deviation of all normal sinus RR intervals (SDNN [ms]--period I: 73.94+/-25.02, period II: 91.63+/-35.99, period III: 75.06+/-27.62; I-II: p<0.05, II-III: p<0.05) and standard deviation of the averaged normal sinus RR intervals for all 5-mm segments (SDANN [ms]--period I: 47.78+/-22.69, period II: 60.72+/-27.55, period III: 47.12+/-23.21; I-II: p<0.05, II-III: p<0.05) were significantly increased. As well as very low frequency (VLF [ms2]--period I: 456.62+/-214.13, period II: 566.84+/-216.99, period III: 477.43+/-203.94; I-II: p<0.05), low frequency (LF [ms(2)]--period I: 607.97+/-201.33, period II: 758.28+/-307.90, period III: 627.09+/-220.33; I-II: p<0.01, II-III: p<0.05) and high frequency (HF [ms(2)]--period I: 538.44+/-290.63, period II: 730.31+/-445.78, period III: 590.94+/-301.64; I-II: p<0.05) components were the highest and the LF/HF ratio (period I: 1.48+/-0.38, period II: 1.16+/-0.35, period III: 1.46+/-0.40; I-II: p<0.05, II-III: p<0.05) was the lowest during a call with a mobile phone. The tone of the parasympathetic system measured indirectly by analysis of heart rate variability was increased while sympathetic tone was lowered during the call with use of a mobile phone. It was shown that the call with a mobile phone may change the autonomic balance in healthy subjects. Changes in heart rate variability during the call with a mobile phone could be affected by electromagnetic field but the influence of speaking cannot be excluded.
Monazzam, Mohammad Reza; Shoja, Esmaeil; Zakerian, Seyed Abolfazl; Foroushani, Abbas Rahimi; Shoja, Mohsen; Gharaee, Masoumeh; Asgari, Amin
2018-07-01
This study aimed to investigate the effect of whole-body vibration and ambient lighting, as well as their combined effect on human discomfort, heart rate, and reaction time in laboratory conditions. 44 men were recruited with an average age of 25.4 ± 1.9 years. Each participant was subjected to 12 experimental steps, each step lasting five minutes for four different vibration accelerations in X, Y, and Z axes at a fixed frequency; three different lighting intensities of 50, 500, and 1000 lx were also considered. At each step, a visual computerized reaction test was taken from subjects and their heart rate recorded by pulse oximeter. In addition, the discomfort rate of subjects was measured using Borg scale. Increasing vibration acceleration significantly increased the discomfort rate and heart beat but not the reaction time. Lack of lighting caused more discomfort in the subjects, but there was no significant correlation between lighting intensity with heart rate and reaction time. The results also showed that the combined effect of vibration and lighting had no significant effect on any of the discomfort, heart rate, and reaction time variables. Whole-body vibration is an important factor in the development of human subjective and physiological reactions compared to lighting. Therefore, consideration of the level of vibration to which an individual is exposed in workplaces subject to vibration plays an important role in reducing the level of human discomfort, but its interaction with ambient lighting does not have a significant effect on human subjective and physiological responses.
Sima, Carmen A; Lau, Benny C; Taylor, Carolyn M; van Eeden, Stephan F; Reid, W Darlene; Sheel, Andrew W; Kirkham, Ashley R; Camp, Pat G
2018-03-14
Myocardial infarction (MI) remains under-recognized in chronic lung disease (CLD) patients. Rehabilitation health professionals need accessible clinical measurements to identify the presence of prior MI in order to determine appropriate training prescription. To estimate prior MI in CLD patients entering a pulmonary rehabilitation program, as well as its association with heart rate parameters such as resting heart rate and chronotropic response index. Retrospective cohort design. Pulmonary rehabilitation outpatient clinic in a tertiary care university-affiliated hospital. Eighty-five CLD patients were studied. Electrocardiograms at rest and peak cardiopulmonary exercise testing, performed before pulmonary rehabilitation, were analyzed. Electrocardiographic evidence of prior MI, quantified by the Cardiac Infarction Injury Score (CIIS), was contrasted with reported myocardial events and then correlated with resting heart rate and chronotropic response index parameters. CIIS, resting heart rate, and chronotropic response index. Sixteen CLD patients (19%) demonstrated electrocardiographic evidence of prior MI, but less than half (8%) had a reported MI history (P < .05). The Cohen's kappa test revealed poor level of agreement between CIIS and medical records (kappa = 0.165), indicating that prior MI diagnosis was under-reported in the medical records. Simple and multiple regression analyses showed that resting heart rate but not chronotropic response index was positively associated with CIIS in our population (R 2 = 0.29, P < .001). CLD patients with a resting heart rate higher than 80 beats/min had approximately 5 times higher odds of having prior MI, as evidenced by a CIIS ≥20. CLD patients entering pulmonary rehabilitation are at risk of unreported prior MI. Elevated resting heart rate seems to be an indicator of prior MI in CLD patients; therefore, careful adjustment of training intensity such as intermittent training is recommended under these circumstances. III. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
A fatigue monitoring system based on time-domain and frequency-domain analysis of pulse data
NASA Astrophysics Data System (ADS)
Shen, Jiaai
2018-04-01
Fatigue is almost a problem that everyone would face, and a psychosis that everyone hates. If we can test people's fatigue condition and remind them of the tiredness, dangers in life, for instance, traffic accidents and sudden death will be effectively reduced, people's fatigued operations will be avoided. And people can be assisted to have access to their own and others' physical condition in time to alternate work with rest. The article develops a wearable bracelet based on FFT Pulse Frequency Spectrum Analysis and IBI's standard deviation and range calculation, according to people's heart rate (BPM) and inter-beat interval (IBI) while being tired and conscious. The hardware part is based on Arduino, pulse rate sensor, and Bluetooth module, and the software part is relied on network micro database and APP. By doing sample experiment to get more accurate standard value to judge tiredness, we prove that we can judge people's fatigue condition based on heart rate (BPM) and inter-beat interval (IBI).
MCCLAIN, SHANNON L.; BROOKS, ALEXA M.; JARVIS, SARA S.
2017-01-01
Controlled or paced breathing is often used as a stress reduction technique but the impact on blood pressure (BP) and sympathetic outflow have not been consistently reported. The purpose of this study was to determine whether a controlled breathing (12 breaths/min, CB) rate would be similar to an individual’s spontaneous breathing (SB) rate. Secondly, would a CB rate of 12 breaths/min alter heart rate (HR), BP, and indices of muscle sympathetic nerve activity (MSNA). Twenty-one subjects (10 women, 11 men) performed two trials: SB, where the subject chose a comfortable breathing rate; and CB, where the subject breathed at a pace of 12 breaths/min. Each trial was 6 min during which respiratory waveforms, HR, BP (systolic, SBP; diastolic, DBP), and MSNA were recorded. During CB, the 6 min average breathing frequency (14±4 vs 12±1 breaths/min, P<0.05 for SB and CB, respectively), MSNA burst frequency (18±12 vs 14±10 bursts/min, P<0.01) and MSNA burst incidence (28±19 vs 21± 6 bursts/100 heart beats, P<0.01) were significantly lower than during SB. HR (66±9 vs 67±9 beats/min, P<0.05) was higher during CB. SBP (120±13 vs 121±15 mmHg, P=0.741), DBP (56±8 vs 57±9 mmHg, P=0.768), and MSNA total activity (166±94 vs 145±102 a.u./min, P=0.145) were not different between the breathing conditions. In conclusion, an acute reduction in breathing frequency such as that observed during CB elicited a decrease in indices of MSNA (burst frequency and incidence) with no change in BP. PMID:28344733
McClain, Shannon L; Brooks, Alexa M; Jarvis, Sara S
2017-01-01
Controlled or paced breathing is often used as a stress reduction technique but the impact on blood pressure (BP) and sympathetic outflow have not been consistently reported. The purpose of this study was to determine whether a controlled breathing (12 breaths/min, CB) rate would be similar to an individual's spontaneous breathing (SB) rate. Secondly, would a CB rate of 12 breaths/min alter heart rate (HR), BP, and indices of muscle sympathetic nerve activity (MSNA). Twenty-one subjects (10 women, 11 men) performed two trials: SB, where the subject chose a comfortable breathing rate; and CB, where the subject breathed at a pace of 12 breaths/min. Each trial was 6 min during which respiratory waveforms, HR, BP (systolic, SBP; diastolic, DBP), and MSNA were recorded. During CB, the 6 min average breathing frequency (14±4 vs 12±1 breaths/min, P <0.05 for SB and CB, respectively), MSNA burst frequency (18±12 vs 14±10 bursts/min, P <0.01) and MSNA burst incidence (28±19 vs 21± 6 bursts/100 heart beats, P <0.01) were significantly lower than during SB. HR (66±9 vs 67±9 beats/min, P <0.05) was higher during CB. SBP (120±13 vs 121±15 mmHg, P =0.741), DBP (56±8 vs 57±9 mmHg, P =0.768), and MSNA total activity (166±94 vs 145±102 a.u./min, P =0.145) were not different between the breathing conditions. In conclusion, an acute reduction in breathing frequency such as that observed during CB elicited a decrease in indices of MSNA (burst frequency and incidence) with no change in BP.
Momota, Yukihiro; Takano, Hideyuki; Kani, Koichi; Matsumoto, Fumihiro; Motegi, Katsumi; Aota, Keiko; Yamamura, Yoshiko; Omori, Mayuko; Tomioka, Shigemasa; Azuma, Masayuki
2013-03-01
Burning mouth syndrome (BMS) is characterized by the following subjective complaints without distinct organic changes: burning sensation in mouth or chronic pain of tongue. BMS is also known as glossodynia; both terms are used equivalently in Japan. Although the real cause of BMS is still unknown, it has been pointed out that BMS is related to some autonomic abnormality, and that stellate ganglion near-infrared irradiation (SGR) corrects the autonomic abnormality. Frequency analysis of heart rate variability (HRV) is expected to be useful for assessing autonomic abnormality. This study investigated whether frequency analysis of HRV could reveal autonomic abnormality associated with BMS, and whether autonomic changes were corrected after SGR. Eight subjects received SGR; the response to SGR was assessed by frequency analysis of HRV. No significant difference of autonomic activity concerning low-frequency (LF) norm, high-frequency (HF) norm, and low-frequency/high-frequency (LF/HF) was found between SGR effective and ineffective groups. Therefore, we proposed new parameters: differential normalized low frequency (D LF norm), differential normalized high frequency (D HF norm), and differential low-frequency/high-frequency (D LF/HF), which were defined as differentials between original parameters just before and after SGR. These parameters as indexes of responsiveness of autonomic nervous system (ANS) revealed autonomic changes in BMS, and BMS seems to be related to autonomic instability rather than autonomic imbalance. Frequency analysis of HRV revealed the autonomic instability associated with BMS and enabled tracing of autonomic changes corrected with SGR. It is suggested that frequency analysis of HRV is very useful in follow up of BMS and for determination of the therapeutic efficacy of SGR. Wiley Periodicals, Inc.
Martelli, Davide; Silvani, Alessandro; McAllen, Robin M; May, Clive N; Ramchandra, Rohit
2014-10-01
The lack of noninvasive approaches to measure cardiac sympathetic nerve activity (CSNA) has driven the development of indirect estimates such as the low-frequency (LF) power of heart rate variability (HRV). Recently, it has been suggested that LF HRV can be used to estimate the baroreflex modulation of heart period (HP) rather than cardiac sympathetic tone. To test this hypothesis, we measured CSNA, HP, blood pressure (BP), and baroreflex sensitivity (BRS) of HP, estimated with the modified Oxford technique, in conscious sheep with pacing-induced heart failure and in healthy control sheep. We found that CSNA was higher and systolic BP and HP were lower in sheep with heart failure than in control sheep. Cross-correlation analysis showed that in each group, the beat-to-beat changes in HP correlated with those in CSNA and in BP, but LF HRV did not correlate significantly with either CSNA or BRS. However, when control sheep and sheep with heart failure were considered together, CSNA correlated negatively with HP and BRS. There was also a negative correlation between CSNA and BRS in control sheep when considered alone. In conclusion, we demonstrate that in conscious sheep, LF HRV is neither a robust index of CSNA nor of BRS and is outperformed by HP and BRS in tracking CSNA. These results do not support the use of LF HRV as a noninvasive estimate of either CSNA or baroreflex function, but they highlight a link between CSNA and BRS. Copyright © 2014 the American Physiological Society.
Cardiorespiratory interactions in humans and animals: Rhythms for life.
Elstad, Maja; O'Callaghan, Erin L; Smith, Alexander J; Ben-Tal, A; Ramchandra, Rohit
2018-03-09
The cardiorespiratory system exhibits oscillations from a range of sources. One of the most studied oscillations is heart rate variability, which is thought to be beneficial and can serve as an index of a healthy cardiovascular system. Heart rate variability is dampened in many diseases including depression, autoimmune diseases, hypertension and heart failure. Thus, understanding the interactions that lead to heart rate variability, and its physiological role, could help with prevention, diagnosis and treatment of cardiovascular diseases. In this review we consider three types of cardiorespiratory interactions; Respiratory Sinus Arrhythmia - variability in heart rate at the frequency of breathing, Cardioventilatory Coupling - synchronization between the heart beat and the onset of inspiration, and Respiratory Stroke Volume Synchronization - constant phase difference between the right and the left stroke volumes over one respiratory cycle. While the exact physiological role of these oscillations continues to be debated, the redundancies in the mechanisms responsible for its generation and its strong evolutionary conservation point to the importance of cardiorespiratory interactions. The putative mechanisms driving cardiorespiratory oscillations as well as the physiological significance of these oscillations will be reviewed. We suggest that cardiorespiratory interactions have the capacity to both dampen the variability in systemic blood flow as well as improve the efficiency of work done by the heart while maintaining physiological levels of arterial CO 2 . Given that reduction in variability is a prognostic indicator of disease, we argue that restoration of this variability via pharmaceutical or device-based approaches may be beneficial in prolonging life.
Taylor, Edwin W; Leite, Cleo A C; Sartori, Marina R; Wang, Tobias; Abe, Augusto S; Crossley, Dane A
2014-03-01
Heart rate in vertebrates is controlled by activity in the autonomic nervous system. In spontaneously active or experimentally prepared animals, inhibitory parasympathetic control is predominant and is responsible for instantaneous changes in heart rate, such as occur at the first air breath following a period of apnoea in discontinuous breathers like inactive reptiles or species that surface to air breathe after a period of submersion. Parasympathetic control, exerted via fast-conducting, myelinated efferent fibres in the vagus nerve, is also responsible for beat-to-beat changes in heart rate such as the high frequency components observed in spectral analysis of heart rate variability. These include respiratory modulation of the heartbeat that can generate cardiorespiratory synchrony in fish and respiratory sinus arrhythmia in mammals. Both may increase the effectiveness of respiratory gas exchange. Although the central interactions generating respiratory modulation of the heartbeat seem to be highly conserved through vertebrate phylogeny, they are different in kind and location, and in most species are as yet little understood. The heart in vertebrate embryos possesses both muscarinic cholinergic and β-adrenergic receptors very early in development. Adrenergic control by circulating catecholamines seems important throughout development. However, innervation of the cardiac receptors is delayed and first evidence of a functional cholinergic tonus on the heart, exerted via the vagus nerve, is often seen shortly before or immediately after hatching or birth, suggesting that it may be coordinated with the onset of central respiratory rhythmicity and subsequent breathing.
Effects of cigarette smoking on cardiac autonomic function during dynamic exercise.
Mendonca, Goncalo V; Pereira, Fernando D; Fernhall, Bo
2011-06-01
The purpose of this study was to investigate the acute effect of cigarette smoking on cardiac autonomic function in young adult smokers during dynamic exercise. Fourteen healthy young smokers (21.4 ± 3.4 years) performed peak and submaximal exercise protocols under control and smoking conditions. Resting and submaximal beat-to-beat R-R series were recorded and spectrally decomposed using the fast Fourier transformation. Smoking resulted in a significant decrease in work time, VO(2peak) and peak O(2) pulse (P < 0.05). Heart rate increased at rest and during submaximal exercise after smoking (P < 0.05). The raw high frequency and low frequency power were significantly reduced by smoking, both at rest and during exercise (P < 0.05). The low to high frequency ratio was higher after smoking (P < 0.05). The normalised low frequency power was also significantly increased by smoking, but only at rest (P < 0.05). These data demonstrate that the tachycardic effect elicited by smoking is accompanied by acute changes in heart rate spectral components both at rest and during exercise. Therefore, the cardiac autonomic control is altered by smoking not only at rest, but also during exercise, resulting in reduced vagal modulation and increased sympathetic dominance.
EFFECTIVE INDICES FOR MONITORING MENTAL WORKLOAD WHILE PERFORMING MULTIPLE TASKS.
Hsu, Bin-Wei; Wang, Mao-Jiun J; Chen, Chi-Yuan; Chen, Fang
2015-08-01
This study identified several physiological indices that can accurately monitor mental workload while participants performed multiple tasks with the strategy of maintaining stable performance and maximizing accuracy. Thirty male participants completed three 10-min. simulated multitasks: MATB (Multi-Attribute Task Battery) with three workload levels. Twenty-five commonly used mental workload measures were collected, including heart rate, 12 HRV (heart rate variability), 10 EEG (electroencephalography) indices (α, β, θ, α/θ, θ/β from O1-O2 and F4-C4), and two subjective measures. Analyses of index sensitivity showed that two EEG indices, θ and α/θ (F4-C4), one time-domain HRV-SDNN (standard deviation of inter-beat intervals), and four frequency-domain HRV: VLF (very low frequency), LF (low frequency), %HF (percentage of high frequency), and LF/HF were sensitive to differentiate high workload. EEG α/θ (F4-C4) and LF/HF were most effective for monitoring high mental workload. LF/HF showed the highest correlations with other physiological indices. EEG α/θ (F4-C4) showed strong correlations with subjective measures across different mental workload levels. Operation strategy would affect the sensitivity of EEG α (F4-C4) and HF.
Shiba, Kenji; Nukaya, Masayuki; Tsuji, Toshio; Koshiji, Kohji
2006-01-01
This paper reports on the specific absorption rate (SAR) and the current density analysis of biological tissue surrounding an air-core type of transcutaneous transformer for an artificial heart. The electromagnetic field in the biological tissue surrounding the transformer was analyzed by the transmission-line modeling method, and the SAR and current density as a function of frequency (200k-1 MHz) for a transcutaneous transmission of 20 W were calculated. The model's biological tissue has three layers including the skin, fat and muscle. As a result, the SAR in the vicinity of the transformer is sufficiently small and the normalized SAR value, which is divided by the ICNIRP's basic restriction, is 7 x 10(-3) or less. On the contrary, the current density is slightly in excess of the ICNIRP's basic restrictions as the frequency falls and the output voltage rises. Normalized current density is from 0.2 to 1.2. In addition, the layer in which the current's density is maximized depends on the frequency, the muscle in the low frequency (<700 kHz) and the skin in the high frequency (>700 kHz). The result shows that precision analysis taking into account the biological properties is very important for developing the transcutaneous transformer for TAH.
Effects of stress on heart rate complexity—A comparison between short-term and chronic stress
Schubert, C.; Lambertz, M.; Nelesen, R.A.; Bardwell, W.; Choi, J.-B.; Dimsdale, J.E.
2009-01-01
This study examined chronic and short-term stress effects on heart rate variability (HRV), comparing time, frequency and phase domain (complexity) measures in 50 healthy adults. The hassles frequency subscale of the combined hassles and uplifts scale (CHUS) was used to measure chronic stress. Short-term stressor reactivity was assessed with a speech task. HRV measures were determined via surface electrocardiogram (ECG). Because respiration rate decreased during the speech task (p < .001), this study assessed the influence of respiration rate changes on the effects of interest. A series of repeated-measures analyses of covariance (ANCOVA) with Bonferroni adjustment revealed that short-term stress decreased HR D2 (calculated via the pointwise correlation dimension PD2) (p < .001), but increased HR mean (p < .001), standard deviation of R–R (SDRR) intervals (p < .001), low (LF) (p < .001) and high frequency band power (HF) (p = .009). Respiratory sinus arrhythmia (RSA) and LF/HF ratio did not change under short-term stress. Partial correlation adjusting for respiration rate showed that HR D2 was associated with chronic stress (r = −.35, p = .019). Differential effects of chronic and short-term stress were observed on several HRV measures. HR D2 decreased under both stress conditions reflecting lowered functionality of the cardiac pacemaker. The results confirm the importance of complexity metrics in modern stress research on HRV. PMID:19100813
Effects of stress on heart rate complexity--a comparison between short-term and chronic stress.
Schubert, C; Lambertz, M; Nelesen, R A; Bardwell, W; Choi, J-B; Dimsdale, J E
2009-03-01
This study examined chronic and short-term stress effects on heart rate variability (HRV), comparing time, frequency and phase domain (complexity) measures in 50 healthy adults. The hassles frequency subscale of the combined hassles and uplifts scale (CHUS) was used to measure chronic stress. Short-term stressor reactivity was assessed with a speech task. HRV measures were determined via surface electrocardiogram (ECG). Because respiration rate decreased during the speech task (p<.001), this study assessed the influence of respiration rate changes on the effects of interest. A series of repeated-measures analyses of covariance (ANCOVA) with Bonferroni adjustment revealed that short-term stress decreased HR D2 (calculated via the pointwise correlation dimension PD2) (p<.001), but increased HR mean (p<.001), standard deviation of R-R (SDRR) intervals (p<.001), low (LF) (p<.001) and high frequency band power (HF) (p=.009). Respiratory sinus arrhythmia (RSA) and LF/HF ratio did not change under short-term stress. Partial correlation adjusting for respiration rate showed that HR D2 was associated with chronic stress (r=-.35, p=.019). Differential effects of chronic and short-term stress were observed on several HRV measures. HR D2 decreased under both stress conditions reflecting lowered functionality of the cardiac pacemaker. The results confirm the importance of complexity metrics in modern stress research on HRV.
Chen, Chien-Liang; Tang, Jing-Shia; Li, Ping-Chia; Chou, Pi-Ling
2015-01-01
This study compared the immediate effects of smoking on cardiorespiratory responses to dynamic arm and leg exercises. This randomized crossover study recruited 14 college students. Each participant underwent two sets of arm-cranking (AC) and leg-cycling (LC) exercise tests. The testing sequences of the control trial (participants refrained from smoking for 8 h before testing) and the experimental trial (participants smoked two cigarettes immediately before testing) were randomly chosen. We observed immediate changes in pulmonary function and heart rate variability after smoking and before the exercise test. The participants then underwent graded exercise tests of their arms and legs until reaching exhaustion. We compared the peak work achieved and time to exhaustion during the exercise tests with various cardiorespiratory indices [i.e., heart rate, oxygen consumption (VO2), minute ventilation (VE)]. The differences between the smoking and control trials were calculated using paired t-tests. For the exercise test periods, VO2, heart rate, and VE values were calculated at every 10% increment of the maximal effort time. The main effects of the time and trial, as well as their trial-by-time (4 × 10) interaction effects on the outcome measures, were investigated using repeated measure ANOVA with trend analysis. 5 min after smoking, the participants exhibited reduced forced vital capacities and forced expiratory volumes in the first second (P < 0.05), in addition to elevated resting heart rates (P < 0.001). The high-frequency, low-frequency, and the total power of the heart rate variability were also reduced (P < 0.05) at rest. For the exercise test periods, smoking reduced the time to exhaustion (P = 0.005) and the ventilatory threshold (P < 0.05) in the LC tests, whereas no significant effects were observed in the AC tests. A trend analysis revealed a significant trial-by-time interaction effect for heart rate, VO2, and VE during the graded exercise test (all P < 0.001). Lower VO2 and VE levels were exhibited in the exercise response of the smoking trial than in those of the control LC trials, whereas no discernable inter-trial difference was observed in the AC trials. Moreover, the differences in heart rate and VE response between the LC and AC exercises were significantly smaller after the participants smoked. This study verified that smoking significantly decreased performance and cardiorespiratory responses to leg exercises. However, the negative effects of smoking on arm exercise performance were not as pronounced.
Technical aspects and clinical implications of high frequency jet ventilation with a solenoid valve.
Carlon, G C; Miodownik, S; Ray, C; Kahn, R C
1981-01-01
High frequency jet ventilation (HFJV) is an incompletely studied technique of mechanical respiratory support. The authors have built a ventilator based on a solenoid valve, that allows independent selection of respiratory rate and inspiratory/expiratory ratio. The ventilator can be synchronized to the heart rate. Humidification is provided by warm saline dripped in front of the injector nozzle, so that the jet stream itself acts as a nebulizer. Tube diameter, length, and deformability are fundamental determinants of inspiratory flow rate and wave form. Cannula kinking and inadequate humidification were the most significant sources of complications.
Newborn infant pain assessment using heart rate variability analysis.
Faye, Papa M; De Jonckheere, Julien; Logier, Regis; Kuissi, Eliane; Jeanne, Mathieu; Rakza, Thameur; Storme, Laurent
2010-01-01
Systems controlling cardiovascular function are closely coupled with the perception of pain. Heart rate variability (HRV) is a well-established noninvasive measure of cardiac autonomic control. We hypothesized that pain may alter HRV in the newborn infant and that HRV analysis could be used as an indicator of prolonged pain in the newborn infant. To test the hypothesis, we measured the magnitude of the heart rate high-frequency variations using an innovative High Frequency Variability Index (HFVI) in newborn infants at risk of postoperative pain. We investigated newborn infants with a gestational age (GA) more than 34 weeks, and who were admitted after a major surgical procedure. Inclusions ranged from 2 to 72 hours after the surgery. The postoperative pain was scored using EDIN scale (neonatal pain and discomfort scale) at the end of the 2 hours recording period. The infants were separated in: (1) Group "Low EDIN," when EDIN<5; and (2) Group "High EDIN," when EDIN >=5. Predictive positive and negative values of a threshold value of HFVI in assessing pain have been studied. Twenty-eight newborn infants were enrolled in the study (mean GA=37.8+/-1.5 wk) at a median delay between the surgery and the recording of 5 hours. Mean EDIN were 2+/-1 and 7+/-2 in respectively the groups "Low EDIN" and "High EDIN." The 2 groups were similar for GA, basal heart and respiratory rates, SpO2, mean arterial blood pressure, and morphine infusion rate. HFVI was significantly lower in the group "High EDIN" than in the group "Low EDIN" (0.7+/-0.2 vs. 1.2+/-0.3, respectively; P<0.01). An HFVI <0.9 was able to predict an EDIN score >=5, with a sensitivity of 90%, and a specificity of 75%. The results of this study indicate that postoperative pain is associated with a decreased high-frequency HRV in full-term newborn infants. Our findings suggest that HRV could be used as an indicator to assess prolonged pain in the newborn infants.
Martiniano, Eli Carlos; Santana, Milana Drumond Ramos; Barros, Érico Luiz Damasceno; do Socorro da Silva, Maria; Garner, David Matthew; de Abreu, Luiz Carlos; Valenti, Vitor E
2018-01-17
Music can improve the efficiency of medical treatment when correctly associated with drug action, reducing risk factors involving deteriorating cardiac function. We evaluated the effect of musical auditory stimulus associated with anti-hypertensive medication on heart rate (HR) autonomic control in hypertensive subjects. We evaluated 37 well-controlled hypertensive patients designated for anti-hypertensive medication. Heart rate variability (HRV) was calculated from the HR monitor recordings of two different, randomly sorted protocols (control and music) on two separate days. Patients were examined in a resting condition 10 minutes before medication and 20 minutes, 40 minutes and 60 minutes after oral medication. Music was played throughout the 60 minutes after medication with the same intensity for all subjects in the music protocol. We noted analogous response of systolic and diastolic arterial pressure in both protocols. HR decreased 60 minutes after medication in the music protocol while it remained unchanged in the control protocol. The effects of anti-hypertensive medication on SDNN (Standard deviation of all normal RR intervals), LF (low frequency, nu), HF (high frequency, nu) and alpha-1 scale were more intense in the music protocol. In conclusion, musical auditory stimulus increased HR autonomic responses to anti-hypertensive medication in well-controlled hypertensive subjects.
Hallman, David M; Mathiassen, Svend Erik; Lyskov, Eugene
2015-01-01
We determined the extent to which heart rate variability (HRV) responses to daily physical activity differ between subjects with and without chronic neck pain. Twenty-nine subjects (13 women) with chronic neck pain and 27 age- and gender-matched healthy controls participated. Physical activity (accelerometry), HRV (heart rate monitor), and spatial location (Global Positioning System (GPS)) were recorded for 74 hours. GPS data were combined with a diary to identify periods of work and of leisure at home and elsewhere. Time- and frequency-domain HRV indices were calculated and stratified by period and activity type (lying/sitting, standing, or walking). ANCOVAs with multiple adjustments were used to disclose possible group differences in HRV. The pain group showed a reduced HRV response to physical activity compared with controls (p = .001), according to the sympathetic-baroreceptor HRV index (LF/HF, ratio between low- and high-frequency power), even after adjustment for leisure time physical activity, work stress, sleep quality, mental health, and aerobic capacity (p = .02). The parasympathetic response to physical activity did not differ between groups. Relying on long-term monitoring of physical behavior and heart rate variability, we found an aberrant sympathetic-baroreceptor response to daily physical activity among subjects with chronic neck pain.
Mendonca, Goncalo V; Pereira, Fernando D; Fernhall, Bo
2013-01-01
Persons with Down syndrome (DS) are at high risk for cardiovascular morbidity and mortality, and there is compelling evidence of autonomic dysfunction in these individuals. The main purpose of this study was to determine whether a combined aerobic and resistance exercise intervention produces similar results in cardiac autonomic function between adults with and without DS. Twenty-five participants (13 DS; 12 non-DS), aged 27-50 years, were included. Aerobic training was performed 3 days/week for 30 min at 65-85% of peak oxygen uptake (VO(2peak)). Resistance training was prescribed for 2 days/week and consisted of two rotations in a circuit of 9 exercises at 12-repetition-maximum. There was a significant improvement in the VO(2peak) and muscle strength of participants with and without DS after training. Heart rate recovery improved at 1 min post-exercise, but only in participants with DS. Both groups of participants exhibited a similar increase in normalized high frequency power and of decrease in normalized low frequency power after training. Therefore, 12 weeks of exercise training enhanced the heart rate recovery in adults with DS, but not in those without DS. Contrasting, the intervention elicited similar gains between groups for cardiovagal modulation. Copyright © 2012 Elsevier Ltd. All rights reserved.
Henje Blom, E; Olsson, E M; Serlachius, E; Ericson, M; Ingvar, M
2010-04-01
The aim of this study was to investigate heart rate variability (HRV) in a clinical sample of female adolescents with anxiety disorders (AD) and/or major depressive disorder (MDD) compared with healthy controls and to assess the effect of selective serotonin reuptake inhibitors (SSRI) on HRV. Heart rate variability was measured in adolescent female psychiatric patients with AD and/or MDD (n = 69), mean age 16.8 years (range: 14.5-18.4), from 13 out-patient clinics and in healthy controls (n = 65), mean age 16.5 years (range: 15.9-17.7). HRV was registered in the sitting position during 4 min with no interventions. Logarithmically transformed high frequency HRV (HF), low frequency HRV (LF) and standard deviation of inter beat intervals (SDNN) were lower in the clinical sample compared with the controls (Cohen's d for HF = 0.57, LF = 0.55, SDNN = 0.60). This was not explained by body mass index, blood pressure or physical activity. Medication with SSRI explained 15.5% of the total variance of HF, 3.0% of LF and 6.5% of SDNN. Adolescent female psychiatric patients with AD and/or MDD show reduced HRV compared with healthy controls. Medication with SSRI explained a part of this difference.
2016-01-01
A novel method of extracting heart rate and oxygen saturation from a video-based biosignal is described. The method comprises a novel modular continuous wavelet transform approach which includes: performing the transform, undertaking running wavelet archetyping to enhance the pulse information, extraction of the pulse ridge time–frequency information [and thus a heart rate (HRvid) signal], creation of a wavelet ratio surface, projection of the pulse ridge onto the ratio surface to determine the ratio of ratios from which a saturation trending signal is derived, and calibrating this signal to provide an absolute saturation signal (SvidO2). The method is illustrated through its application to a video photoplethysmogram acquired during a porcine model of acute desaturation. The modular continuous wavelet transform-based approach is advocated by the author as a powerful methodology to deal with noisy, non-stationary biosignals in general. PMID:27382479
Transthoracic Cardiac Ultrasonic Stimulation Induces a Negative Chronotropic Effect
Buiochi, Elaine Belassiano; Miller, Rita J.; Hartman, Emily; Buiochi, Flavio; Bassani, Rosana A.; Costa, Eduardo T.; O’Brien, William D.
2013-01-01
The objective of this study is to investigate cardiac bioeffects resulting from ultrasonic stimulation using a specific set of acoustical parameters. Ten Sprague–Dawley rats were anesthetized and exposed to 1-MHz ultrasound pulses of 3-MPa peak rarefactional pressure and approximately 1% duty factor. The pulse repetition frequency started slightly above the heart rate and was decreased by 1 Hz every 10 s, for a total exposure duration of 30 s. The control group was composed of five rats. Two-way analysis of variance for repeated measures and Bonferroni post hoc tests were used to compare heart rate and ejection fraction, which was used as an index of myocardial contractility. It was demonstrated for the first time that transthoracic ultrasound has the potential to decrease the heart rate by ~20%. The negative chronotropic effect lasted for at least 15 min after ultrasound exposure and there was no apparent gross damage to the cardiac tissue. PMID:23221214
NASA Astrophysics Data System (ADS)
Tremoleda, Jordi L.; Alvarez, Karl; Aden, Abdirahman; Donnan, Robert; Michael-Titus, Adina T.; Tomlins, Peter H.
2017-12-01
Traumatic brain injury (TBI) results in direct vascular disruption, triggering edema, and reduction in cerebral blood flow. Therefore, understanding the pathophysiology of brain microcirculation following TBI is important for the development of effective therapies. Optical coherence angiography (OCA) is a promising tool for evaluating TBI in rodent models. We develop an approach to OCA that uses the heart-rate frequency to discriminate between static tissue and vasculature. This method operates on intensity data and is therefore not phase sensitive. Furthermore, it does not require spatial overlap of voxels and thus can be applied to pre-existing datasets for which oversampling may not have been explicitly considered. Heart-rate sensitive OCA was developed for dynamic assessment of mouse microvasculature post-TBI. Results show changes occurring at 5-min intervals within the first 50 min of injury.
Rocha, P L; Branco, L G
1998-03-01
We assessed seasonal variations in the effects of temperature on hypoxia-induced alterations in the bullfrog Rana catesbeiana by measuring the heart rate, arterial blood pressure, breathing frequency, metabolic rate, blood gas levels, acid-base status and plasma glucose concentration. Regardless of the season, decreased body temperature was accompanied by a reduction in heart and breathing frequencies. Lower temperatures caused a significant decrease in arterial blood pressure during all four seasons. Hypoxia-induced changes in breathing frequency were proportional to body temperature and were more pronounced during winter, less so during spring and autumn and even smaller during summer. Season had no effect on the relationship between hypoxia and heart rate. At any temperature tested, the rate of oxygen consumption had a tendency to be highest during summer and lowest during winter, but the difference was significant only at 35 degrees C. The PaO2 and pH values showed no significant change during the year, but PaCO2 was almost twice as high during winter than in summer and spring, indicating increased plasma bicarbonate levels. Lower temperatures were accompanied by decreased plasma glucose levels, and this effect was greater during summer and smaller during autumn. Hypoxia-induced hyperglycaemia was influenced by temperature and season. During autumn and winter, plasma glucose level remained elevated regardless of temperature, probably to avoid dehydration and/or freezing. In winter, the bullfrog may be exposed not only to low temperatures but also to hypoxia. These animals show temperature-dependent responses that may be beneficial since at low body temperatures the set-points of most physiological responses to hypoxia are reduced, regardless of the season.
Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate.
Marchon, Niyan; Naik, Gourish; Pai, K R
2018-01-01
Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal's well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F 1 ) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.
Bogucki, Sz; Noszczyk-Nowak, A
2017-03-28
Heart rate variability is an established risk factor for mortality in both healthy dogs and animals with heart failure. The aim of this study was to compare short-term heart rate variability (ST-HRV) parameters from 60-min electrocardiograms in dogs with sick sinus syndrome (SSS, n=20) or chronic mitral valve disease (CMVD, n=20) and healthy controls (n=50), and to verify the clinical application of ST-HRV analysis. The study groups differed significantly in terms of both time - and frequency- domain ST-HRV parameters. In the case of dogs with SSS and healthy controls, particularly evident differences pertained to HRV parameters linked directly to the variability of R-R intervals. Lower values of standard deviation of all R-R intervals (SDNN), standard deviation of the averaged R-R intervals for all 5-min segments (SDANN), mean of the standard deviations of all R-R intervals for all 5-min segments (SDNNI) and percentage of successive R-R intervals >50 ms (pNN50) corresponded to a decrease in parasympathetic regulation of heart rate in dogs with CMVD. These findings imply that ST-HRV may be useful for the identification of dogs with SSS and for detection of dysautonomia in animals with CMVD.
Dynamic characteristics of heart rate control by the autonomic nervous system in rats.
Mizuno, Masaki; Kawada, Toru; Kamiya, Atsunori; Miyamoto, Tadayoshi; Shimizu, Shuji; Shishido, Toshiaki; Smith, Scott A; Sugimachi, Masaru
2010-09-01
We estimated the transfer function of autonomic heart rate (HR) control by using random binary sympathetic or vagal nerve stimulation in anaesthetized rats. The transfer function from sympathetic stimulation to HR response approximated a second-order, low-pass filter with a lag time (gain, 4.29 +/- 1.55 beats min(1) Hz(1); natural frequency, 0.07 +/- 0.03 Hz; damping coefficient, 1.96 +/- 0.64; and lag time, 0.73 +/- 0.12 s). The transfer function from vagal stimulation to HR response approximated a first-order, low-pass filter with a lag time (gain, 8.84 +/- 4.51 beats min(1) Hz(1); corner frequency, 0.12 +/- 0.06 Hz; and lag time, 0.12 +/- 0.08 s). These results suggest that the dynamic characteristics of HR control by the autonomic nervous system in rats are similar to those of larger mammals.
Organisational injustice and impaired cardiovascular regulation among female employees.
Elovainio, M; Kivimäki, M; Puttonen, S; Lindholm, H; Pohjonen, T; Sinervo, T
2006-02-01
To examine the relation between perceived organisational justice and cardiovascular reactivity in women. The participants were 57 women working in long term care homes. Heart rate variability and systolic arterial pressure variability were used as markers of autonomic function. Organisational justice was measured using the scale of Moorman. Data on other risk factors were also collected. Results from logistic regression models showed that the risk for increased low frequency band systolic arterial pressure variability was 3.8-5.8 times higher in employees with low justice than in employees with high justice. Low perceived justice was also related to an 80% excess risk of reduced high frequency heart rate variability compared to high perceived justice, but this association was not statistically significant. These findings are consistent with the hypothesis that cardiac dysregulation is one stress mechanism through which a low perceived justice of decision making procedures and interpersonal treatment increases the risk of health problems in personnel.
Maetzler, Walter; Karam, Marie; Berger, Monika Fruhmann; Heger, Tanja; Maetzler, Corina; Ruediger, Heinz; Bronzova, Juliana; Lobo, Patricia Pita; Ferreira, Joaquim J; Ziemssen, Tjalf; Berg, Daniela
2015-03-01
The autonomic nervous system (ANS) is regularly affected in Parkinson's disease (PD). Information on autonomic dysfunction can be derived from e.g. altered heart rate variability (HRV) and sympathetic skin response (SSR). Such parameters can be quantified easily and measured repeatedly which might be helpful for evaluating disease progression and therapeutic outcome. In this 2-center study, HRV and SSR of 45 PD patients and 26 controls were recorded. HRV was measured during supine metronomic breathing and analyzed in time- and frequency-domains. SSR was evoked by repetitive auditory stimulation. Various ANS parameters were compared (1) between patients and healthy controls, (2) to clinical scales (Unified Parkinson's disease rating scale, Mini-Mental State Examination, Becks Depression Inventory), and (3) to disease duration. Root mean square of successive differences (RMSSD) and low frequency/high frequency (LF/HF) ratio differed significantly between PD and controls. Both, HRV and SSR parameters showed low or no association with clinical scores. Time-domain parameters tended to be affected already at early PD stages but did not consistently change with longer disease duration. In contrast, frequency-domain parameters were not altered in early PD phases but tended to be lower (LF, LF/HF ratio), respectively higher (HF) with increasing disease duration. This report confirms previous results of altered ANS parameters in PD. In addition, it suggests that (1) these ANS parameters are not relevantly associated with motor, behavioral, and cognitive changes in PD, (2) time-domain parameters are useful for the assessment of early PD, and (3) frequency-domain parameters are more closely associated with disease duration.
Vigo, Daniel E; Dominguez, Javier; Guinjoan, Salvador M; Scaramal, Mariano; Ruffa, Eduardo; Solernó, Juan; Siri, Leonardo Nicola; Cardinali, Daniel P
2010-04-19
Heart rate variability (HRV) is a complex signal that results from the contribution of different sources of oscillation related to the autonomic nervous system activity. Although linear analysis of HRV has been applied to sleep studies, the nonlinear dynamics of HRV underlying frequency components during sleep is less known. We conducted a study to evaluate nonlinear HRV within independent frequency components in wake status, slow-wave sleep (SWS, stages III or IV of non-rapid eye movement sleep), and rapid-eye-movement sleep (REM). The sample included 10 healthy adults. Polysomnography was performed to detect sleep stages. HRV was studied globally during each phase and then very low frequency (VLF), low frequency (LF) and high frequency (HF) components were separated by means of the wavelet transform algorithm. HRV nonlinear dynamics was estimated with sample entropy (SampEn). A higher SampEn was found when analyzing global variability (Wake: 1.53+/-0.28, SWS: 1.76+/-0.32, REM: 1.45+/-0.19, p=0.005) and VLF variability (Wake: 0.13+/-0.03, SWS: 0.19+/-0.03, REM: 0.14+/-0.03, p<0.001) at SWS. REM was similar to wake status regarding nonlinear HRV. We propose nonlinear HRV is a useful index of the autonomic activity that characterizes the different sleep-wake cycle stages. 2009 Elsevier B.V. All rights reserved.
Silva, Ana F G; Bonatti, Rodolfo; Batatinha, Julio A P; Nearing, Bruce D; Zeng, Dewan; Belardinelli, Luiz; Verrier, Richard L
2017-03-01
We examined the effects of the selective late INa inhibitor eleclazine on the 50% probability of successful defibrillation (DFT50) before and after administration of amiodarone to determine its suitability for use in patients with implantable cardioverter defibrillators (ICDs). In 20 anesthetized pigs, transvenous active-fixation cardiac defibrillation leads were fluoroscopically positioned into right ventricular apex through jugular vein. ICDs were implanted subcutaneously. Dominant frequency of ventricular fibrillation was analyzed by fast Fourier transform. The measurements were made before drug administration (control), and at 40 minutes after vehicle, eleclazine (2 mg/kg, i.v., bolus over 15 minutes), or subsequent/single amiodarone administration (10 mg/kg, i.v., bolus over 10 minutes). Eleclazine did not alter DFT50, dominant frequency, heart rate, or mean arterial pressure (MAP). Subsequent amiodarone increased DFT50 (P = 0.006), decreased dominant frequency (P = 0.022), and reduced heart rate (P = 0.031) with no change in MAP. Amiodarone alone increased DFT50 (P = 0.005; NS compared to following eleclazine) and decreased dominant frequency (P = 0.003; NS compared to following eleclazine). Selective late INa inhibition with eleclazine does not alter DFT50 or dominant frequency of ventricular fibrillation when administered alone or in combination with amiodarone. Accordingly, eleclazine would not be anticipated to affect the margin of defibrillation safety in patients with ICDs.
Hoyer, Dirk; Leder, Uwe; Hoyer, Heike; Pompe, Bernd; Sommer, Michael; Zwiener, Ulrich
2002-01-01
The heart rate variability (HRV) is related to several mechanisms of the complex autonomic functioning such as respiratory heart rate modulation and phase dependencies between heart beat cycles and breathing cycles. The underlying processes are basically nonlinear. In order to understand and quantitatively assess those physiological interactions an adequate coupling analysis is necessary. We hypothesized that nonlinear measures of HRV and cardiorespiratory interdependencies are superior to the standard HRV measures in classifying patients after acute myocardial infarction. We introduced mutual information measures which provide access to nonlinear interdependencies as counterpart to the classically linear correlation analysis. The nonlinear statistical autodependencies of HRV were quantified by auto mutual information, the respiratory heart rate modulation by cardiorespiratory cross mutual information, respectively. The phase interdependencies between heart beat cycles and breathing cycles were assessed basing on the histograms of the frequency ratios of the instantaneous heart beat and respiratory cycles. Furthermore, the relative duration of phase synchronized intervals was acquired. We investigated 39 patients after acute myocardial infarction versus 24 controls. The discrimination of these groups was improved by cardiorespiratory cross mutual information measures and phase interdependencies measures in comparison to the linear standard HRV measures. This result was statistically confirmed by means of logistic regression models of particular variable subsets and their receiver operating characteristics.
Hörnchen, H; Betz, R; Kotlarek, F; Roebruck, P
1983-01-01
In 1965 URBACH et al. and RUDOLPH et al. [35, 39] described a loss of heart rate variability in severely ill neonates. In this study we investigated the correlation between instantaneous heart rate patterns and status diagnosis. We used a microprocessor-based cardiorespirography system. Seventy five newborn infants (51 prematures and 24 term neonates) were studied for about 12 hours each. Twenty nine patients had a second record after the first investigation. Parameters were: Type of frequency and oscillation, long time variability (LTV), short time variability (STV) and the newly introduced P-value (maximal difference between two successive R-peaks in five minutes). We found clear differences between the study groups. With increasing severity of illness mean values ("group mean values") of long time variability, short time variability and P-value decreased. Fixed heart rate became predominant. The most pronounced loss of heart rate variability was seen in infants with severe intracranial bleeding, thus offering a tentative diagnosis. For statistical analysis long time variability and the silent oscillation type have been proved as best parameters for this diagnosis. Severely decreased heart rate variations also have been seen in infants with acute renal failure--possibly because of brain edema--, after application of muscle relaxants, repeated doses of sedatives, and after prolonged anesthesia. Otherwise, the heart rate variability was probably dependent on age and gestational age in prematures and newborn infants without intracranial bleeding. It is possible to use microprocessor-based long time cardiorespirography as a simple screening method for the diagnosis of neonatal intracerebral bleeding. In future experiences transcutaneous measurements of oxygen tension should be included.
DiBona, G F; Sawin, L L
2001-08-01
Sympathetic nerve activity, including that in the kidney, is increased in heart failure with increased plasma concentrations of norepinephrine and the vasoconstrictor cotransmitter neuropeptide Y (NPY). We examined the contribution of NPY to sympathetically mediated alterations in kidney function in normal and heart failure rats. Heart failure rats were created by left coronary ligation and myocardial infarction. In anesthetized normal rats, the NPY Y(1) receptor antagonist, H 409/22, at two doses, had no effect on heart rate, arterial pressure, or renal hemodynamic and excretory function. In conscious severe heart failure rats, high-dose H 409/22 decreased mean arterial pressure by 8 +/- 2 mm Hg but had no effect in normal and mild heart failure rats. During graded frequency renal sympathetic nerve stimulation (0 to 10 Hz), high-dose H 409/22 attenuated the decreases in renal blood flow only at 10 Hz (-36% +/- 5%, P <.05) in normal rats but did so at both 4 (-29% +/- 4%, P <.05) and 10 Hz (-33% +/- 5%, P <.05) in heart failure rats. The glomerular filtration rate, urinary flow rate, and sodium excretion responses to renal sympathetic nerve stimulation were not affected by high-dose H 409/22 in either normal or heart failure rats. NPY does not participate in the regulation of kidney function and arterial pressure in normal conscious or anesthetized rats. When sympathetic nervous system activity is increased, as in heart failure and intense renal sympathetic nerve stimulation, respectively, a small contribution of NPY to maintenance of arterial pressure and to sympathetic renal vasoconstrictor responses may be identified.
Physiological basis for human autonomic rhythms
NASA Technical Reports Server (NTRS)
Eckberg, D. L.
2000-01-01
Oscillations of arterial pressures, heart periods, and muscle sympathetic nerve activity have been studied intensively in recent years to explore otherwise obscure human neurophysiological mechanisms. The best-studied rhythms are those occurring at breathing frequencies. Published evidence indicates that respiratory fluctuations of muscle sympathetic nerve activity and electrocardiographic R-R intervals result primarily from the action of a central 'gate' that opens during expiration and closes during inspiration. Parallel respiratory fluctuations of arterial pressures and R-R intervals are thought to be secondary to arterial baroreflex physiology: changes in systolic pressure provoke changes in the R-R interval. However, growing evidence suggests that these parallel oscillations result from the influence of respiration on sympathetic and vagal-cardiac motoneurones rather than from baroreflex physiology. There is a rapidly growing literature on the use of mathematical models of low- and high-frequency (respiratory) R-R interval fluctuations in characterizing instantaneous 'sympathovagal balance'. The case for this approach is based primarily on measurements made with patients in upright tilt. However, the strong linear relation between such measures as the ratio of low- to high-frequency R-R interval oscillations and the angle of the tilt reflects exclusively the reductions of the vagal (high-frequency) component. As the sympathetic component does not change in tilt, the low- to high-frequency R-R interval ratio provides no proof that sympathetic activity increases. Moreover, the validity of extrapolating from measurements performed during upright tilt to measurements during supine rest has not been established. Nonetheless, it is clear that measures of heart rate variability provide important prognostic information in patients with cardiovascular diseases. It is not known whether reduced heart rate variability is merely a marker for the severity of disease or a measurement that identifies functional reflex abnormalities contributing to terminal dysrhythmias.
Passive Fetal Heart Monitoring System
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Mowrey, Dennis L. (Inventor)
2003-01-01
A fetal heart monitoring system and method for detecting and processing acoustic fetal heart signals transmitted by different signal transmission modes. One signal transmission mode, the direct contact mode, occurs in a first frequency band when the fetus is in direct contact with the maternal abdominal wall. Another signal transmission mode, the fluid propagation mode, occurs in a second frequency band when the fetus is in a recessed position with no direct contact with the maternal abdominal wall. The second frequency band is relatively higher than the first frequency band. The fetal heart monitoring system and method detect and process acoustic fetal heart signals that are in the first frequency band and in the second frequency band.
Effects of smoking cessation on heart rate variability among long-term male smokers.
Harte, Christopher B; Meston, Cindy M
2014-04-01
Cigarette smoking has been shown to adversely affect heart rate variability (HRV), suggesting dysregulation of cardiac autonomic function. Conversely, smoking cessation is posited to improve cardiac regulation. The aim of the present study was to examine the effects of smoking cessation on HRV among a community sample of chronic smokers. Sixty-two healthy male smokers enrolled in an 8-week smoking cessation program involving a nicotine transdermal patch treatment. Participants were assessed at baseline (while smoking regularly), at mid-treatment (while using a high-dose patch), and at follow-up, 4 weeks after patch discontinuation. Both time-domain (standard deviation of normal-to-normal (NN) intervals (SDNN), square root of the mean squared difference of successive NN intervals (RMSSD), and percent of NN intervals for which successive heartbeat intervals differed by at least 50 ms (pNN50)) and frequency-domain (low frequency (LF), high frequency (HF), LF/HF ratio) parameters of HRV were assessed at each visit. Successful quitters (n = 20), compared to those who relapsed (n = 42), displayed significantly higher SDNN, RMSSD, pNN50, LF, and HF at follow-up, when both nicotine and smoke free. Smoking cessation significantly enhances HRV in chronic male smokers, indicating improved autonomic modulation of the heart. Results suggest that these findings may be primarily attributable to nicotine discontinuation rather than tobacco smoke discontinuation alone.
Deng, Xin; Feng, Xuhui; Li, Sen; Gao, Ya; Yu, Bingzhi; Li, Gensong
2015-01-01
Previous literatures have indicated that hypothalamic paraventricular nucleus (PVN) neurons are important for regulating the level of sympathetic and vagal nervous activity. Sympathovagal balance is closely related to heart rate variability (HRV). However, it still requires further elucidation regarding the effect of PVN on HRV by regulating sympathovagal balance. To detect the influence of the PVN on HRV, we evaluated the changes in time domain (including standard deviation of the R-R intervals (SDNN), and the root mean square of successive differences (RMSSD)) and frequency domain (including low frequency (LFnu), high frequency (HFnu) and the ratio of LF/HF) in HRV upon appropriate electronic stimulation, and lesions on the PVN of the rat in vivo. Cardiac vagal modulation was evaluated by HFnu; sympathetic modulation was evaluated by LFnu. Sympathovagal balance was evaluated by LF/HF and SDNN. Upon electronic stimulating (less than 0.6 mA) to the PVN of rats, we found that LFnu and HFnu changed correspondingly but recovered after the stimulation. When the PVN of the rats was injured, the RR intervals were enhanced with the rats' unilaterally or bilaterally injured PVN, especially the bilateral lesion. Meanwhile, LFnu, LF/HF and SDNN decreased gradually, accompanied with an increase of HFnu levels. So these PVN changes may indicate alterations of the sympathovagal balance.
[Effect of substance P on cardiac autonomic nervous function in rats].
Deng, Lijun; Li, Jing; Yan, Fuping; Lu, Jie
2009-12-01
Forty SD rats were divided into 5 groups: control group, SP groups (5 microg/kg,10 microg/kg, 20 microg/kg) and spantide II plus SP group. An analysis of heart rate variability (HRV) was used to detect the changes of HRV parameters before and after intravenous injection of SP in order to investigate the effect of substance P on cardiac autonomic nervous function and the corresponding mechanism. (1) There were significant differences in most HRV parameters for the three different doses of SP. Mean heart period (MHP), absolute power of ultra-low frequency and high frequency band (APU, APH), total power (TPV) and ratio of power in ultra-low to high frequency band (RUH) increased, while mean heart rate (MHR) and chaos intensity (HCC) decreased during the 30 minutes. Each peak amplitude of HRV parameters went higher and showed up ahead of the upward doses of SP. (2) Significant change was seen in each of the parameters between spantide II plus SP group and high-dose SP group. These data idicate that, after intravenous injection of different doses of SP, both cardiac sympathetic nervous system activity and parasympathetic nervous system activity increase, and the function of cardiac autonomic nervous becomes instable and unbalanced. The effect of SP may be dose dependent, and it is possibly mediated by neurokinin-1(NK-1) receptor.
Shi, Ping; Hu, Sijung; Yu, Hongliu
2018-02-01
The aim of this study was to analyze the recovery of heart rate variability (HRV) after treadmill exercise and to investigate the autonomic nervous system response after exercise. Frequency domain indices, i.e., LF(ms 2 ), HF(ms 2 ), LF(n.u.), HF(n.u.) and LF/HF, and lagged Poincaré plot width (SD1 m ) and length (SD2 m ) were introduced for comparison between the baseline period (Pre-E) before treadmill running and two periods after treadmill running (Post-E1 and Post-E2). The correlations between lagged Poincaré plot indices and frequency domain indices were applied to reveal the long-range correlation between linear and nonlinear indices during the recovery of HRV. The results suggested entirely attenuated autonomic nervous activity to the heart following the treadmill exercise. After the treadmill running, the sympathetic nerves achieved dominance and the parasympathetic activity was suppressed, which lasted for more than 4 min. The correlation coefficients between lagged Poincaré plot indices and spectral power indices could separate not only Pre-E and two sessions after the treadmill running, but also the two sessions in recovery periods, i.e., Post-E1 and Post-E2. Lagged Poincaré plot as an innovative nonlinear method showed a better performance over linear frequency domain analysis and conventional nonlinear Poincaré plot.
NASA Technical Reports Server (NTRS)
Patwardhan, A. R.; Vallurupalli, S.; Evans, J. M.; Bruce, E. N.; Knapp, C. F.
1995-01-01
We investigated the effects of voluntary control of breathing on autonomic function in cardiovascular regulation. Variability in heart rate was compared between 5 min of spontaneous and controlled breathing. During controlled breathing, for 5 min, subjects voluntarily reproduced their own spontaneous breathing pattern (both rate and volume on a breath-by-breath basis). With the use of this experimental design, we could unmask the effects of voluntary override of the spontaneous respiratory pattern generator on autonomic function in cardiovascular regulation without the confounding effects of altered respiratory pattern. Results from 10 subjects showed that during voluntary control of breathing, mean values of heart rate and blood pressure increased, whereas fractal and spectral powers in heart rate in the respiratory frequency region decreased. End-tidal PCO2 was similar during spontaneous and controlled breathing. These results indicate that the act of voluntary control of breathing decreases the influence of the vagal component, which is the principal parasympathetic influence in cardiovascular regulation.
Pahlevan, Niema M.; Tavallali, Peyman; Rinderknecht, Derek G.; Petrasek, Danny; Matthews, Ray V.; Hou, Thomas Y.; Gharib, Morteza
2014-01-01
The reductionist approach has dominated the fields of biology and medicine for nearly a century. Here, we present a systems science approach to the analysis of physiological waveforms in the context of a specific case, cardiovascular physiology. Our goal in this study is to introduce a methodology that allows for novel insight into cardiovascular physiology and to show proof of concept for a new index for the evaluation of the cardiovascular system through pressure wave analysis. This methodology uses a modified version of sparse time–frequency representation (STFR) to extract two dominant frequencies we refer to as intrinsic frequencies (IFs; ω1 and ω2). The IFs are the dominant frequencies of the instantaneous frequency of the coupled heart + aorta system before the closure of the aortic valve and the decoupled aorta after valve closure. In this study, we extract the IFs from a series of aortic pressure waves obtained from both clinical data and a computational model. Our results demonstrate that at the heart rate at which the left ventricular pulsatile workload is minimized the two IFs are equal (ω1 = ω2). Extracted IFs from clinical data indicate that at young ages the total frequency variation (Δω = ω1 − ω2) is close to zero and that Δω increases with age or disease (e.g. heart failure and hypertension). While the focus of this paper is the cardiovascular system, this approach can easily be extended to other physiological systems or any biological signal. PMID:25008087
Epinephrine syringe exchange events in a paediatric cardiovascular ICU: analysing the storm.
Achuff, Barbara-Jo; Achuff, Jameson C; Park, Hwan H; Moffett, Brady; Acosta, Sebastian; Rusin, Craig G; Checchia, Paul A
2018-03-01
Introduction Haemodynamically unstable patients can experience potentially hazardous changes in vital signs related to the exchange of depleted syringes of epinephrine to full syringes. The purpose was to determine the measured effects of epinephrine syringe exchanges on the magnitude, duration, and frequency of haemodynamic disturbances in the hour after an exchange event (study) relative to the hours before (control). Materials and methods Beat-to-beat vital signs recorded every 2 seconds from bedside monitors for patients admitted to the paediatric cardiovascular ICU of Texas Children's Hospital were collected between 1 January, 2013 and 30 June, 2015. Epinephrine syringe exchanges without dose/flow change were obtained from electronic records. Time, magnitude, and duration of changes in systolic blood pressure and heart rate were characterised using Matlab. Significant haemodynamic events were identified and compared with control data. In all, 1042 syringe exchange events were found and 850 (81.6%) had uncorrupted data for analysis. A total of 744 (87.5%) exchanges had at least 1 associated haemodynamic perturbation including 2958 systolic blood pressure and 1747 heart-rate changes. Heart-rate perturbations occurred 37% before exchange and 63% after exchange, and 37% of systolic blood pressure perturbations happened before syringe exchange, whereas 63% occurred after syringe exchange with significant differences found in systolic blood pressure frequency (p<0.001), duration (p<0.001), and amplitude (p<0.001) compared with control data. This novel data collection and signal processing analysis showed a significant increase in frequency, duration, and magnitude of systolic blood pressure perturbations surrounding epinephrine syringe exchange events.
Is autonomic modulation different between European and Chinese astronauts?
Liu, Jiexin; Li, Yongzhi; Verheyden, Bart; Chen, Shanguang; Chen, Zhanghuang; Gai, Yuqing; Liu, Jianzhong; Gao, Jianyi; Xie, Qiong; Yuan, Ming; Li, Qin; Li, Li; Aubert, André E
2015-01-01
The objective was to investigate autonomic control in groups of European and Chinese astronauts and to identify similarities and differences. Beat-to-beat heart rate and finger blood pressure, brachial blood pressure, and respiratory frequency were measured from 10 astronauts (five European taking part in three different space missions and five Chinese astronauts taking part in two different space missions). Data recording was performed in the supine and standing positions at least 10 days before launch, and 1, 3, and 10 days after return. Cross-correlation analysis of heart rate and systolic pressure was used to assess cardiac baroreflex modulation. A fixed breathing protocol was performed to measure respiratory sinus arrhythmia and low-frequency power of systolic blood pressure variability. Although baseline cardiovascular parameters before spaceflight were similar in all astronauts in the supine position, a significant increase in sympathetic activity and a decrease in vagal modulation occurred in the European astronauts when standing; spaceflight resulted in a remarkable vagal decrease in European astronauts only. Similar baseline supine and standing values for heart rate, mean arterial pressure, and respiratory frequency were shown in both groups. Standing autonomic control was based on a balance of higher vagal and sympathetic modulation in European astronauts. Post-spaceflight orthostatic tachycardia was observed in all European astronauts, whereas post-spaceflight orthostatic tachycardia was significantly reduced in Chinese astronauts. The basis for orthostatic intolerance is not apparent; however, many possibilities can be considered and need to be further investigated, such as genetic diversities between races, astronaut selection, training, and nutrition, etc.
Is Autonomic Modulation Different between European and Chinese Astronauts?
Liu, Jiexin; Li, Yongzhi; Verheyden, Bart; Chen, Shanguang; Chen, Zhanghuang; Gai, Yuqing; Liu, Jianzhong; Gao, Jianyi; Xie, Qiong; Yuan, Ming; Li, Qin; Li, Li; Aubert, André E.
2015-01-01
Purpose The objective was to investigate autonomic control in groups of European and Chinese astronauts and to identify similarities and differences. Methods Beat-to-beat heart rate and finger blood pressure, brachial blood pressure, and respiratory frequency were measured from 10 astronauts (five European taking part in three different space missions and five Chinese astronauts taking part in two different space missions). Data recording was performed in the supine and standing positions at least 10 days before launch, and 1, 3, and 10 days after return. Cross-correlation analysis of heart rate and systolic pressure was used to assess cardiac baroreflex modulation. A fixed breathing protocol was performed to measure respiratory sinus arrhythmia and low-frequency power of systolic blood pressure variability. Results Although baseline cardiovascular parameters before spaceflight were similar in all astronauts in the supine position, a significant increase in sympathetic activity and a decrease in vagal modulation occurred in the European astronauts when standing; spaceflight resulted in a remarkable vagal decrease in European astronauts only. Similar baseline supine and standing values for heart rate, mean arterial pressure, and respiratory frequency were shown in both groups. Standing autonomic control was based on a balance of higher vagal and sympathetic modulation in European astronauts. Conclusion Post-spaceflight orthostatic tachycardia was observed in all European astronauts, whereas post-spaceflight orthostatic tachycardia was significantly reduced in Chinese astronauts. The basis for orthostatic intolerance is not apparent; however, many possibilities can be considered and need to be further investigated, such as genetic diversities between races, astronaut selection, training, and nutrition, etc. PMID:25799561
Jacinto, Cynthia P.; Gastaldi, Ada C.; Aguiar, Daniela Y.; Maida, Karina D.; Souza, Hugo C. D.
2013-01-01
Background The effects of physical therapy on heart rate variability (HRV), especially in children, are still inconclusive. Objective We investigated the effects of conventional physical therapy (CPT) for airway clearance and nasotracheal suction on the HRV of pediatric patients with acute bronchiolitis. Method 24 children were divided into two groups: control group (CG, n=12) without respiratory diseases and acute bronchiolitis group (BG, n=12). The heart rate was recorded in the BG at four different moments: basal recording (30 minutes), 5 minutes after the CPT (10 minutes), 5 minutes after nasotracheal suction (10 minutes), and 40 minutes after nasotracheal suction (30 minutes). The CG was subjected to the same protocol, except for nasotracheal suction. To assess the HRV, we used spectrum analysis, which decomposes the heart rate oscillations into frequency bands: low frequency (LF=0.04-0.15Hz), which corresponds mainly to sympathetic modulation; and high frequency (HF=0.15-1.2Hz), corresponding to vagal modulation. Results Under baseline conditions, the BG showed higher values in LF oscillations, lower values in HF oscillations, and increased LF/HF ratio when compared to the CG. After CPT, the values for HRV in the BG were similar to those observed in the CG during basal recording. Five minutes after nasotracheal suction, the BG showed a decrease in LF and HF oscillations; however, after 40 minutes, the values were similar to those observed after application of CPT. Conclusions The CPT and nasotracheal suction, both used for airway clearance, promote improvement in autonomic modulation of HRV in children with acute bronchiolitis. PMID:24271093
Evidence for cardiovascular autonomic dysfunction in neonates with coarctation of the aorta.
Polson, Jaimie W; McCallion, Naomi; Waki, Hidefumi; Thorne, Gareth; Tooley, Mark A; Paton, Julian F R; Wolf, Andrew R
2006-06-20
Coarctation of the aorta (CoA) is associated with hypertension and abnormalities of blood pressure control, which persist after late repair. Assumptions that neonatal repair would prevent development of blood pressure abnormalities have not been supported by recent data. We hypothesized that early pathological adjustment of autonomic cardiovascular function may already be established in the neonate with coarctation. We studied 8 otherwise well neonates with simple CoA and compared measures of spontaneous baroreflex sensitivity, heart rate variability, and blood pressure variability with 13 healthy newborn babies. Spontaneous baroreflex sensitivity was calculated with sequence methodology from an ECG, and noninvasive blood pressure was recorded with a Portapres. Heart rate variability was determined with time- and frequency-domain measures. Blood pressure variability was measured in the frequency domain. In comparison with normal controls, neonates with CoA had raised blood pressure (78.9+/-3.8 versus 67.1+/-2.1 mm Hg), depressed baroreflex sensitivity (8.7+/-1.5 versus 13.8+/-1.1 ms/mm Hg), reduced heart rate variability (total power 16.5+/-3.1 versus 31.5+/-2.2 ms2), and an increase in the high-frequency component of blood pressure variability (3.1+/-0.3 versus 2.2+/-0. 2 mm Hg2). This is not the pattern expected if neonates with CoA simply had subclinical cardiac failure. These data suggest that infants with CoA already show signs of pathological adjustment of autonomic cardiovascular homeostasis. Further longitudinal studies are required to determine whether these alterations play a role in the increased risk of late hypertension in these patients.
An exploratory study on scientific investigations in homeopathy using medical analyzer.
Mishra, Nirupama; Muraleedharan, K Charan; Paranjpe, Akalpita Sriniwas; Munta, Devendra Kumar; Singh, Hari; Nayak, Chaturbhuja
2011-08-01
The action of homeopathic medicines, in ultra-high dilution, is not directly observable. An attempt was made to explore autonomic response of selective homeopathic medicines, in healthy persons, using Medical Analyzer System (Electronics Division, Bhabha Atomic Research Centre, Mumbai, India). The objective of the study was to observe the action of homeopathic medicines on physiologic variability of heart rate and blood flow. Pre- and postinterventional variability spectra of heart rate and blood flow of 77 subjects were recorded with the Medical Analyzer System, administering homeopathic preparations of Aconitum napellus (6c, 10M), Arsenicum album (200c, 1M), Gelsemium sempervirens (200c, 1M), Phosphorus (200c, 1M), Pulsatilla nigricans (200c) and Sulphur (200c, 1M) versus placebo control. The amplitude of the peaks viz. low-frequency, medium-frequency, and high-frequency was measured for postintervention analysis. An increase in the amplitude of any valid peak by 100% or a decrease by 50% was considered as significant change. Aconitum napellus produced a response in heart rate variability (HRV) with 30c potency and in blood flow variability with 1M potency. Sulphur 200c and 1M, Gelsemium 200c and Pulsatilla 200c, produced a 62.5% response in HRV against the placebo response of 16.6%. Gelsemium, Phosphorus, and Sulphur produced a response in blood flow variability with a 1M potency, similar to the response of Aconitum napellus 1M. These data suggest that it is possible to record the response of homeopathic medicines on physiologic parameters of the autonomic nervous system.
Fehlert, E; Willmann, K; Fritsche, L; Linder, K; Mat-Husin, H; Schleger, F; Weiss, M; Kiefer-Schmidt, I; Brucker, S; Häring, H-U; Preissl, H; Fritsche, A
2017-11-01
Gestational diabetes mellitus (GDM) potentially harms the child before birth. We previously found GDM to be associated with developmental changes in the central nervous system. We now hypothesise that GDM may also impact on the fetal autonomic nervous system under metabolic stress like an oral glucose tolerance test (OGTT). We measured heart rate variability (HRV) of mothers and fetuses during a three-point OGTT using fetal magnetocardiography (fMCG). Measurements were performed in the fMEG Centre in Tübingen. After exclusion of 23 participants, 13 pregnant women with GDM and 36 pregnant women with normal glucose tolerance were examined. All women underwent the same examination setting with OGTT during which fMCG was recorded three times. Parameters of heart rate variability were measured. Compared with mothers with normal glucose regulation, mothers with GDM showed increased heart rate but no significant differences of maternal HRV. In contrast, HRV in fetuses of mothers with GDM differed from those in the metabolically healthy group regarding standard deviation normal to normal beat (SDNN) (P = 0.012), low-frequency band (P = 0.008) and high-frequency band (P = 0.031). These HRV parameters exhibit a decrease only in GDM fetuses during the second hour of the OGTT. These results show an altered response of the fetal autonomic nervous system to metabolic stress in GDM-complicated pregnancies. Hence, disturbances in maternal glucose metabolism might not only impact on the central nervous system of the fetus but may also affect the fetal autonomic nervous system. Metabolic stress reveals a different response of fetal autonomic nervous system in GDM-complicated pregnancies. © 2016 Royal College of Obstetricians and Gynaecologists.
Gonçalves, Hernâni; Fernandes, Diana; Pinto, Paula; Ayres-de-Campos, Diogo; Bernardes, João
2017-11-01
Male gender is considered a risk factor for several adverse perinatal outcomes. Fetal gender effect on fetal heart rate (FHR) has been subject of several studies with contradictory results. The importance of maternal heart rate (MHR) monitoring during labor has also been investigated, but less is known about the effect of fetal gender on MHR. The aim of this study is to simultaneously assess maternal and FHR variability during labor in relation with fetal gender. Simultaneous MHR and FHR recordings were obtained from 44 singleton term pregnancies during the last 2 hr of labor (H 1, H 2 ). Heart rate tracings were analyzed using linear (time- and frequency-domain) and nonlinear indices. Both linear and nonlinear components were considered in assessing FHR and MHR interaction, including cross-sample entropy (cross-SampEn). Mothers carrying male fetuses (n = 22) had significantly higher values for linear indices related with MHR average and variability and sympatho-vagal balance, while the opposite occurred in the high-frequency component and most nonlinear indices. Significant differences in FHR were only observed in H 1 with higher entropy values in female fetuses. Assessing the differences between FHR and MHR, statistically significant differences were obtained in most nonlinear indices between genders. A significantly higher cross-SampEn was observed in mothers carrying female fetuses (n = 22), denoting lower synchrony or similarity between MHR and FHR. The variability of MHR and the synchrony/similarity between MHR and FHR vary with respect to fetal gender during labor. These findings suggest that fetal gender needs to be taken into account when simultaneously monitoring MHR and FHR. © 2017 Wiley Periodicals, Inc.
Noble, Donald J; MacDowell, Camden J; McKinnon, Michael L; Neblett, Tamra I; Goolsby, William N; Hochman, Shawn
2017-02-01
Numerous environmental and genetic factors can contribute significantly to behavioral and cardiorespiratory variability observed experimentally. Affordable technologies that allow for noninvasive home cage capture of physio-behavioral variables should enhance understanding of inter-animal variability including after experimental interventions. We assessed whether EPIC electric field sensors (Plessey Semiconductors) embedded within or attached externally to a rodent's home cage could accurately record respiration, heart rate, and motor behaviors. Current systems for quantification of behavioral variables require expensive specialty equipment, while measures of respiratory and heart rate are often provided by surgically implanted or chronically affixed devices. Sensors accurately encoded imposed sinusoidal changes in electric field tested at frequencies ranging from 0.5-100Hz. Mini-metronome arm movements were easily detected, but response magnitude was highly distance dependent. Sensors accurately reported respiration during whole-body plethysmography. In anesthetized rodents, PVC tube-embedded sensors provided accurate mechanical detection of both respiratory and heart rate. Comparable success was seen in naturally behaving animals at rest or sleeping when sensors were attached externally. Video-verified motor behaviors (sniffing, grooming, chewing, and rearing) were detectable and largely separable by their characteristic voltage fluctuations. Larger movement-related events had comparably larger voltage dynamics that easily allowed for a broad approximation of overall motor activity. Spectrograms were used to quickly depict characteristic frequencies in long-lasting recordings, while filtering and thresholding software allowed for detection and quantification of movement-related physio-behavioral events. EPIC electric field sensors provide a means for affordable non-contact home cage detection of physio-behavioral variables. Copyright © 2016 Elsevier B.V. All rights reserved.
Temperature effects on aerobic scope and cardiac performance of European perch (Perca fluviatilis).
Jensen, Denise Lyager; Overgaard, Johannes; Wang, Tobias; Gesser, Hans; Malte, Hans
2017-08-01
Several recent studies have highlighted how impaired cardiac performance at high temperatures and in hypoxia may compromise the capacity for oxygen transport. Thus, at high temperatures impaired cardiac capacity is proposed to reduce oxygen transport to a degree that lowers aerobic scope and compromises thermal tolerance (the oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis). To investigate this hypothesis, we measured aerobic and cardiac performance of a eurythermal freshwater teleost, the European perch (Perca fluviatilis). Rates of oxygen consumption were measured during rest and activity at temperatures between 5°C and 27°C, and we evaluated cardiac function by in vivo measurements of heart rate and in vitro studies to determine contractility of myocardial strips. Aerobic scope increased progressively from 5°C to 21°C, after which it levelled off. Heart rate showed a similar response. We found little difference between resting and active heart rate at high temperature suggesting that increased cardiac scope during activity is primarily related to changes in stroke volume. To examine the effects of temperature on cardiac capacity, we measured isometric force development in electrically paced myocardial preparations during different combinations of temperature, pacing frequency, oxygenation and adrenergic stimulation. The force-frequency product increased markedly upon adrenergic stimulation at 21 and 27°C (with higher effects at 21°C) and the cardiac preparations were highly sensitive to hypoxia. These findings suggest that at (critically) high temperatures, cardiac output may diminish due to a decreased effect of adrenergic stimulation and that this effect may be further exacerbated if the heart becomes hypoxic. Hence cardiac limitations may contribute to the inability to increase aerobic scope at high temperatures in the European perch (Perca fluviatilis). Copyright © 2017 Elsevier Ltd. All rights reserved.
Souza, Naiara M; Giacon, Thais R; Pacagnelli, Francis L; Barbosa, Marianne P C R; Valenti, Vitor E; Vanderlei, Luiz C M
2016-10-01
Autonomic diabetic neuropathy is one of the most common complications of type 1 diabetes mellitus, and studies using heart rate variability to investigate these individuals have shown inconclusive results regarding autonomic nervous system activation. Aims To investigate the dynamics of heart rate in young subjects with type 1 diabetes mellitus through nonlinear and linear methods of heart rate variability. We evaluated 20 subjects with type 1 diabetes mellitus and 23 healthy control subjects. We obtained the following nonlinear indices from the recurrence plot: recurrence rate (REC), determinism (DET), and Shanon entropy (ES), and we analysed indices in the frequency (LF and HF in ms2 and normalised units - nu - and LF/HF ratio) and time domains (SDNN and RMSSD), through analysis of 1000 R-R intervals, captured by a heart rate monitor. There were reduced values (p<0.05) for individuals with type 1 diabetes mellitus compared with healthy subjects in the following indices: DET, REC, ES, RMSSD, SDNN, LF (ms2), and HF (ms2). In relation to the recurrence plot, subjects with type 1 diabetes mellitus demonstrated lower recurrence and greater variation in their plot, inter-group and intra-group, respectively. Young subjects with type 1 diabetes mellitus have autonomic nervous system behaviour that tends to randomness compared with healthy young subjects. Moreover, this behaviour is related to reduced sympathetic and parasympathetic activity of the autonomic nervous system.
Ruffini, Nuria; D'Alessandro, Giandomenico; Mariani, Nicolò; Pollastrelli, Alberto; Cardinali, Lucia; Cerritelli, Francesco
2015-01-01
Context: Heart Rate Variability (HRV) indicates how heart rate changes in response to inner and external stimuli. HRV is linked to health status and it is an indirect marker of the autonomic nervous system (ANS) function. Objective: To investigate the influence of osteopathic manipulative treatment (OMT) on cardiac autonomic modulation in healthy subjects, compared with sham therapy and control group. Methods: Sixty-six healthy subjects, both male and female, were included in the present 3-armed randomized placebo controlled within subject cross-over single blinded study. Participants were asymptomatic adults (26.7 ± 8.4 y, 51% male, BMI 18.5 ± 4.8), both smokers and non-smokers and not on medications. At enrollment subjects were randomized in three groups: A, B, C. Standardized structural evaluation followed by a patient need-based osteopathic treatment was performed in the first session of group A and in the second session of group B. Standardized evaluation followed by a protocoled sham treatment was provided in the second session of group A and in the first session of group B. No intervention was performed in the two sessions of group C, acting as a time-control. The trial was registered on clinicaltrials.gov identifier: NCT01908920. Main Outcomes Measures: HRV was calculated from electrocardiography before, during and after the intervention, for a total amount time of 25 min and considering frequency domain as well as linear and non-linear methods as outcome measures. Results: OMT engendered a statistically significant increase of parasympathetic activity, as shown by High Frequency power (p < 0.001), expressed in normalized and absolute unit, and possibly decrease of sympathetic activity, as revealed by Low Frequency power (p < 0.01); results also showed a reduction of Low Frequency/High Frequency ratio (p < 0.001) and Detrended fluctuation scaling exponent (p < 0.05). Conclusions: Findings suggested that OMT can influence ANS activity increasing parasympathetic function and decreasing sympathetic activity, compared to sham therapy and control group. PMID:26300719
Allen, Alexander R; Gullixson, Leah R; Wolhart, Sarah C; Kost, Susan L; Schroeder, Darrell R; Eisenach, John H
2014-02-01
Dietary sodium influences intermediate physiological traits in healthy adults independent of changes in blood pressure. The purpose of this study was to test the hypothesis that dietary sodium affects cardiac autonomic modulation during mental stress. In a prospective, randomized cross-over design separated by 1 month between diets, 70 normotensive healthy young adults (F/M: 44/26, aged 18-38 years) consumed a 5-day low (10 mmol/day), normal (150 mmol), and high (400 mmol) sodium diet followed by heart rate variability (HRV) recordings at rest and during 5-min computerized mental arithmetic. Women were studied in the low hormone phase of the menstrual cycle following each diet. Diet did not affect resting blood pressure, but heart rate (HR) (mean ± SE) was 66 ± 1, 64 ± 1, and 63 ± 1 bpm in low, normal, and high sodium conditions, respectively (analysis of variance P = 0.02). For HRV, there was a main effect of sodium on resting SD of normalized RR intervals (SDNN), square root of the mean squared difference of successive normalized RR intervals (RMSSD), high frequency, low-frequency normalized units (LFnu), and high-frequency normalized units (HFnu) (P < 0.01 for all). The response to low sodium was most marked and consistent with sympathetic activation and reduced vagal activity, with increased LFnu and decreased SDNN, RMSSD, and HFnu compared to both normal and high sodium conditions (P ≤0.05 for all). Dietary sodium-by-mental stress interactions were significant for mean NN, RMSSD, high-frequency power, LFnu, and low frequency/high frequency ratio (P < 0.05 for all). The interactions signify that sodium restriction evoked an increase in resting sympathetic activity and reduced vagal activity to the extent that mental stress caused modest additional disruptions in autonomic balance. Conversely, normal and high sodium evoked a reduction in resting sympathetic activity and incremental increase in resting vagal activity, which were disrupted to a greater extent during mental stress compared to low sodium. We conclude that autonomic control of HRV at rest and during mental stress is altered by dietary sodium in healthy normotensive young adult men and women.
Neural control of heart rate: the role of neuronal networking.
Kember, G; Armour, J A; Zamir, M
2011-05-21
Neural control of heart rate, particularly its sympathetic component, is generally thought to reside primarily in the central nervous system, though accumulating evidence suggests that intrathoracic extracardiac and intrinsic cardiac ganglia are also involved. We propose an integrated model in which the control of heart rate is achieved via three neuronal "levels" representing three control centers instead of the conventional one. Most importantly, in this model control is effected through networking between neuronal populations within and among these layers. The results obtained indicate that networking serves to process demands for systemic blood flow before transducing them to cardiac motor neurons. This provides the heart with a measure of protection against the possibility of "overdrive" implied by the currently held centrally driven system. The results also show that localized networking instabilities can lead to sporadic low frequency oscillations that have the characteristics of the well-known Mayer waves. The sporadic nature of Mayer waves has been unexplained so far and is of particular interest in clinical diagnosis. Copyright © 2011 Elsevier Ltd. All rights reserved.
Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu
2018-05-01
This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P < .05), and shifted respiratory peak toward left (P < .05). Compared to 16 breaths/minute, traditional spectral analysis showed increased LF power and LF/HF ratio, decreased HF power of HRV at 8 breaths per minute (P < .05). As breathing rate decreased, corrected spectral analysis showed increased HF power, decreased LF power, LF/HF ratio of HRV (P < .05). Compared to controls, resting baroreflex sensitivity decreased in hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P < .05) and controls (from 88.49 ± 6.01 to 112.91 ± 7.29 ms/mm Hg, P < .05).Slow breathing can increase HF power and decrease LF power and LF/HF ratio in essential hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.
Endothelin-1 signalling controls early embryonic heart rate in vitro and in vivo.
Karppinen, S; Rapila, R; Mäkikallio, K; Hänninen, S L; Rysä, J; Vuolteenaho, O; Tavi, P
2014-02-01
Spontaneous activity of embryonic cardiomyocytes originates from sarcoplasmic reticulum (SR) Ca(2+) release during early cardiogenesis. However, the regulation of heart rate during embryonic development is still not clear. The aim of this study was to determine how endothelin-1 (ET-1) affects the heart rate of embryonic mice, as well as the pathway through which it exerts its effects. The effects of ET-1 and ET-1 receptor inhibition on cardiac contraction were studied using confocal Ca(2+) imaging of isolated mouse embryonic ventricular cardiomyocytes and ultrasonographic examination of embryonic cardiac contractions in utero. In addition, the amount of ET-1 peptide and ET receptor a (ETa) and b (ETb) mRNA levels were measured during different stages of development of the cardiac muscle. High ET-1 concentration and expression of both ETa and ETb receptors was observed in early cardiac tissue. ET-1 was found to increase the frequency of spontaneous Ca(2+) oscillations in E10.5 embryonic cardiomyocytes in vitro. Non-specific inhibition of ET receptors with tezosentan caused arrhythmia and bradycardia in isolated embryonic cardiomyocytes and in whole embryonic hearts both in vitro (E10.5) and in utero (E12.5). ET-1-mediated stimulation of early heart rate was found to occur via ETb receptors and subsequent inositol trisphosphate receptor activation and increased SR Ca(2+) leak. Endothelin-1 is required to maintain a sufficient heart rate, as well as to prevent arrhythmia during early development of the mouse heart. This is achieved through ETb receptor, which stimulates Ca(2+) leak through IP3 receptors. © 2013 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.
Milani-Nejad, Nima; Canan, Benjamin D; Elnakish, Mohammad T; Davis, Jonathan P; Chung, Jae-Hoon; Fedorov, Vadim V; Binkley, Philip F; Higgins, Robert S D; Kilic, Ahmet; Mohler, Peter J; Janssen, Paul M L
2015-12-15
Cross-bridge cycling rate is an important determinant of cardiac output, and its alteration can potentially contribute to reduced output in heart failure patients. Additionally, animal studies suggest that this rate can be regulated by muscle length. The purpose of this study was to investigate cross-bridge cycling rate and its regulation by muscle length under near-physiological conditions in intact right ventricular muscles of nonfailing and failing human hearts. We acquired freshly explanted nonfailing (n = 9) and failing (n = 10) human hearts. All experiments were performed on intact right ventricular cardiac trabeculae (n = 40) at physiological temperature and near the normal heart rate range. The failing myocardium showed the typical heart failure phenotype: a negative force-frequency relationship and β-adrenergic desensitization (P < 0.05), indicating the expected pathological myocardium in the right ventricles. We found that there exists a length-dependent regulation of cross-bridge cycling kinetics in human myocardium. Decreasing muscle length accelerated the rate of cross-bridge reattachment (ktr) in both nonfailing and failing myocardium (P < 0.05) equally; there were no major differences between nonfailing and failing myocardium at each respective length (P > 0.05), indicating that this regulatory mechanism is preserved in heart failure. Length-dependent assessment of twitch kinetics mirrored these findings; normalized dF/dt slowed down with increasing length of the muscle and was virtually identical in diseased tissue. This study shows for the first time that muscle length regulates cross-bridge kinetics in human myocardium under near-physiological conditions and that those kinetics are preserved in the right ventricular tissues of heart failure patients. Copyright © 2015 the American Physiological Society.
Sobieszczańska-Małek, Małgorzata; Zieliński, Tomasz; Rywik, Tomasz; Piotrowska, Małgorzata; Religa, Grzegorz; Przybyłowski, Piotr; Rózański, Jacek; Korewicki, Jerzy
2010-01-01
Atrial fibrillation (AF) is the most common arrhythmia among patients (pts) with heart failure and has significant influence on survival. to assess prognosis of pts with refractory heart failure (HF) qualified for heart transplantation (HTX). 872 pts (107 W and 765 M) were qualified for HTX between Dec 2003 and Oct 2007. Patient's death or super urgent heart transplantation were considered the end point in Kaplan-Meier survival curves. 680 pts were on sinus rhythm (SR) and 192(22.0%) had atrial fibrillation (AF). During follow-up (1-1464 days, mean 550 days) 155 pts (17.7%) died, 17.65% with SR and 18.23% with AF (ns). EF - mean 21,6 (SR) and 21,8 (FA), NYHA 3,1 (SR), NTproBNP- mean 3635, 4 (SR) and 4349,4 (FA), Arronson - mean 7,8 (SR) and 7,7 (FA). There were no significant differences between groups. We analyzed influence of heart rate (Kaplan-Maier method) on survival. The pts were divided according to HR: gr.I <70/min, gr II 71-89/min, gr III >90/min. The shortest survival rate was noticed in group III. There was no difference in survival between group I and II. The prognosis for patients qualified for heart transplant does not depend on the type of the dominant cardiac rhythm (atrial fibrillation or sinus rhythm). The prognosis is significantly better for those patients whose basic, resting heart rate does not exceed 90 bpm regardless of the rhythm type.
Yildiz, Metin; Doma, Serian
2017-09-26
The effects of effortful swallowing and solid meal ingestions on heart rate variability (HRV) have been examined previously. The effects of spontaneous saliva swallowing on short-term HRV and reliability of HRV analysis have not been studied before. The effect of saliva swallowing on HRV analyses parameters [meanRRI, SDNN (standard deviation of normal-to-normal), LF (low frequency), HF (high frequency) powers, LH/HF] and the reliability of LF and HF powers were investigated by frequency, time-frequency and intraclass correlation coefficient (ICC) analyses. Electrocardiogram and swallowing signal that obtained from an electronic stethoscope placed on the necks of subjects were recorded simultaneously from 30 healthy and young volunteers in sitting position during 15 min. Spontaneous swallowing has been shown to significantly alter some HRV parameters (SDNN, LF power and LF/HF ratio). Time-frequency analysis results showed that the contribution of saliva swallowing to LF (1-58%) and HF (2-42%) powers could change significantly depending on the number of swallowing. The ICC of the LF and HF powers for the successive 5-min signal segments were found 0·89, 0·92, respectively. These values decreased to 0·73 and 0·90 in the subjects with more swallowing rate. When the analyses were made for 2-min signal periods, these values decreased to 0·63 and 0·67. We concluded that spontaneous saliva swallowing can change HRV parameters. We have also seen that changes in swallowing rate and use of short signal segments may reduce the reliability of HRV analyses. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
The calcium–frequency response in the rat ventricular myocyte: an experimental and modelling study
Gattoni, Sara; Røe, Åsmund Treu; Frisk, Michael; Louch, William E.; Niederer, Steven A.
2016-01-01
Key points In the majority of species, including humans, increased heart rate increases cardiac contractility. This change is known as the force–frequency response (FFR). The majority of mammals have a positive force–frequency relationship (FFR). In rat the FFR is controversial.We derive a species‐ and temperature‐specific data‐driven model of the rat ventricular myocyte.As a measure of the FFR, we test the effects of changes in frequency and extracellular calcium on the calcium–frequency response (CFR) in our model and three altered models.The results show a biphasic peak calcium–frequency response, due to biphasic behaviour of the ryanodine receptor and the combined effect of the rapid calmodulin buffer and the frequency‐dependent increase in diastolic calcium.Alterations to the model reveal that inclusion of Ca2+/calmodulin‐dependent protein kinase II (CAMKII)‐mediated L‐type channel and transient outward K+ current activity enhances the positive magnitude calcium–frequency response, and the absence of CAMKII‐mediated increase in activity of the sarco/endoplasmic reticulum Ca2+‐ATPase induces a negative magnitude calcium–frequency response. Abstract An increase in heart rate affects the strength of cardiac contraction by altering the Ca2+ transient as a response to physiological demands. This is described by the force–frequency response (FFR), a change in developed force with pacing frequency. The majority of mammals, including humans, have a positive FFR, and cardiac contraction strength increases with heart rate. However, the rat and mouse are exceptions, with the majority of studies reporting a negative FFR, while others report either a biphasic or a positive FFR. Understanding the differences in the FFR between humans and rats is fundamental to interpreting rat‐based experimental findings in the context of human physiology. We have developed a novel model of rat ventricular electrophysiology and calcium dynamics, derived predominantly from experimental data recorded under physiological conditions. As a measure of FFR, we tested the effects of changes in stimulation frequency and extracellular calcium concentration on the simulated Ca2+ transient characteristics and showed a biphasic peak calcium–frequency relationship, consistent with recent observations of a shift from negative to positive FFR when approaching the rat physiological frequency range. We tested the hypotheses that (1) inhibition of Ca2+/calmodulin‐dependent protein kinase II (CAMKII)‐mediated increase in sarco/endoplasmic reticulum Ca2+‐ATPase (SERCA) activity, (2) CAMKII modulation of SERCA, L‐type channel and transient outward K+ current activity and (3) Na+/K+ pump dynamics play a significant role in the rat FFR. The results reveal a major role for CAMKII modulation of SERCA in the peak Ca2+–frequency response, driven most significantly by the cytosolic calcium buffering system and changes in diastolic Ca2+. PMID:26916026
Impact of space flight on cardiovascular autonomic control
NASA Astrophysics Data System (ADS)
Beckers, F.; Verheyden, B.; Morukov, B.; Aubert, Ae
Introduction: Space flight alters the distribution of blood in the human body, leading to altered cardiovascular neurohumoral regulation with a blunted carotid-cardiac baroreflex. These changes contribute to the occurrence of orthostatic intolerance after space flight. Heart rate variability (HRV) and blood pressure variability (BPV) provide non-invasive means to study the autonomic modulation of the heart. Low frequency (LF) oscillations provide information about sympathetic modulation and baroreflex, while high frequency (HF) modulation is an index of vagal heart rate modulation. Methods: ECG and continuous blood pressure were measured for at least 10 minutes in supine, sitting and standing position 45 days and 10 days (L-45, L-10) before launch; and at 1, 2, 4, 9, 15, 19 and 25 days after return to earth (R+x). In space, ECG and continuous blood pressure were measured at day 5 (FD5) and day 8 (FD8). These measurements were performed in 3. HRV and BPV indices were calculated in time and frequency domain. Results: Measurements in supine position and sitting position did not show as high differences as the measurements in standing position. During space flight heart rate was significantly lower compared to the pre- and post-flight measurements in standing position (RR-values: L-45: 837± 42 ms; FD5: 1004± 40 ms; FD8: 1038± 53 ms; R+1: 587± 21 ms; p<0.05). This was accompanied by a significant increase in the proportion of HF power during space flight and a decrease in LF power. Immediately after space flight both LF and HF modulation of heart rate were extremely depressed compared to the pre-flight conditions (p<0.005). A gradual recovery towards baseline conditions of both indices was observed up to 25 days after return from space (LF: L-45: 3297± 462 ms2; FD5: 1251± 332 ms2; FD8: 1322± 462 ms2; R+1: 547± 188 ms2; R+4: 1958± 709 ms2; R+9: 1220± 148 ms2; R+15: 1704± 497 ms2; R+25: 2644± 573 ms2). However, even 25 days after return, values were below baseline condition. Mean systolic blood pressure did not differ significantly before during and after space flight. In space both LF and HF were decreased compared the standing measurements pre- and post-flight. No evolution was present in BPV after return to Earth. Conclusion: During space flight autonomic modulation is characterised by a vagal predominance. Immediately after return to Earth overall autonomic modulation is extremely depressed. Vasomotor autonomic control is restored rather quickly after space flight, while the restoration of autonomic modulation of heart rate is very slow.
Shi, Shaobo; Liu, Tao; Wang, Dandan; Zhang, Yan; Liang, Jinjun; Yang, Bo; Hu, Dan
2017-07-01
The goal of this study was to assess the effects of N-methyl-d-aspartate (NMDA) receptors activation on heart rate variability (HRV) and susceptibility to atrial fibrillation (AF). Rats were randomized for treatment with saline, NMDA (agonist of NMDA receptors), or NMDA plus MK-801 (antagonist of NMDA receptors) for 2 weeks. Heart rate variability was evaluated by using implantable electrocardiogram telemeters. Atrial fibrillation susceptibility was assessed with programmed stimulation in isolated hearts. Compared with the controls, the NMDA-treated rats displayed a decrease in the standard deviation of normal RR intervals, the standard deviation of the average RR intervals, the mean of the 5-min standard deviations of RR intervals, the root mean square of successive differences, and high frequency (HF); and an increase in low frequency (LF) and LF/HF (all P< 0.01). Additionally, the NMDA-treated rats showed prolonged activation latency and reduced effective refractory period (all P< 0.01). Importantly, AF was induced in all NMDA-treated rats. While atrial fibrosis developed, connexin40 downgraded and metalloproteinase 9 upgraded in the NMDA-treated rats (all P< 0.01). Most of the above alterations were mitigated by co-administering with MK-801. These results indicate that NMDA receptors activation reduces HRV and enhances AF inducibility, with cardiac autonomic imbalance, atrial fibrosis, and degradation of gap junction protein identified as potential mechanistic contributors. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Kreibig, Sylvia D; Wilhelm, Frank H; Roth, Walton T; Gross, James J
2007-09-01
Responses to fear- and sadness-inducing films were assessed using a broad range of cardiovascular (heart rate, T-wave amplitude, low- and high-frequency heart rate variability, stroke volume, preejection period, left-ventricular ejection time, Heather index, blood pressure, pulse amplitude and transit time, and finger temperature), electrodermal (level, response rate, and response amplitude), and respiratory (rate, tidal volume and its variability, inspiratory flow rate, duty cycle, and end-tidal pCO(2)) measures. Subjective emotional experience and facial behavior (Corrugator Supercilii and Zygomaticus Major EMG) served as control measures. Results indicated robust differential physiological response patterns for fear, sadness, and neutral (mean classification accuracy 85%). Findings are discussed in terms of the fight-flight and conservation-withdrawal responses and possible limitations of a valence-arousal categorization of emotion in affective space.
High-Frequency Ultrasound for the Study of Early Mouse Embryonic Cardiovascular System.
Greco, Adelaide; Coda, Anna Rita Daniela; Albanese, Sandra; Ragucci, Monica; Liuzzi, Raffaele; Auletta, Luigi; Gargiulo, Sara; Lamagna, Francesco; Salvatore, Marco; Mancini, Marcello
2015-12-01
An accurate diagnosis of congenital heart defects during fetal development is critical for interventional planning. Mice can be used to generate animal models with heart defects, and high-frequency ultrasound (HFUS) imaging enables in utero imaging of live mouse embryos. A wide range of physiological measurements is possible using Doppler-HFUS imaging; limitations of any single measurement warrant a multiparameter approach to characterize cardiovascular function. Doppler-HFUS was used to explore the embryonic (heart, aorta) and extraembryonic (umbilical blood flow) circulatory systems to create a database in normal mouse embryos between 9.5 and 16.5 days of gestation. Multivariate analyses were performed to explore correlations between gestational age and embryo echocardiographic parameters. Heart rate and peak velocity in the aorta were positively correlated with gestational time, whereas cardiac cycle length, isovolumetric relaxation time, myocardial performance index, and arterial deceleration time of the umbilical cord were negatively correlated with it. Doppler-HFUS facilitated detailed characterization of the embryonic mouse circulation and represents a useful tool for investigation of the early mouse embryonic cardiovascular system. © The Author(s) 2015.
1985-12-31
puretone threshold at ultra-audiometric frequencies (10,000-20,000 Hz; e) Masking Level Differences (MLD) used to assess binaural processing in the auditory...SD in 5 Supine Resting Subjects) I Pre-exposure Mean Exposure Time Control 2.6 Hours 9.8 Hours I Heart Rate 59.8 + 10.7 50.2 + 8.5 63.6* + 14.4 ( beats ...complete absence of ectopic beats by 6 hours post-exposure. 72 FIGURE 26. 1 HEART RATE RESPONSES TO RISING FROM SUPINE TO STANDING POSITION IN SUBJECT (C.H
Doret, Muriel; Spilka, Jiří; Chudáček, Václav; Gonçalves, Paulo; Abry, Patrice
2015-01-01
Background The fetal heart rate (FHR) is commonly monitored during labor to detect early fetal acidosis. FHR variability is traditionally investigated using Fourier transform, often with adult predefined frequency band powers and the corresponding LF/HF ratio. However, fetal conditions differ from adults and modify spectrum repartition along frequencies. Aims This study questions the arbitrariness definition and relevance of the frequency band splitting procedure, and thus of the calculation of the underlying LF/HF ratio, as efficient tools for characterizing intrapartum FHR variability. Study Design The last 30 minutes before delivery of the intrapartum FHR were analyzed. Subjects Case-control study. A total of 45 singletons divided into two groups based on umbilical cord arterial pH: the Index group with pH ≤ 7.05 (n = 15) and Control group with pH > 7.05 (n = 30). Outcome Measures Frequency band-based LF/HF ratio and Hurst parameter. Results This study shows that the intrapartum FHR is characterized by fractal temporal dynamics and promotes the Hurst parameter as a potential marker of fetal acidosis. This parameter preserves the intuition of a power frequency balance, while avoiding the frequency band splitting procedure and thus the arbitrary choice of a frequency separating bands. The study also shows that extending the frequency range covered by the adult-based bands to higher and lower frequencies permits the Hurst parameter to achieve better performance for identifying fetal acidosis. Conclusions The Hurst parameter provides a robust and versatile tool for quantifying FHR variability, yields better acidosis detection performance compared to the LF/HF ratio, and avoids arbitrariness in spectral band splitting and definitions. PMID:26322889
Lindahl, C; Pinzke, S; Herlin, A; Keeling, L J
2016-03-01
Cattle handling is a dangerous activity on dairy farms, and cows are a major cause of injuries to livestock handlers. Even if dairy cows are generally tranquil and docile, when situations occur that they perceive or remember as aversive, they may become agitated and hazardous to handle. This study aimed to compare human-animal interactions, cow behavior, and handler safety when moving cows to daily milking and moving cows to more rarely occurring and possibly aversive hoof trimming. These processes were observed on 12 Swedish commercial dairy farms. The study included behavioral observations of handler and cows and cow heart rate recordings, as well as recording frequencies of situations and incidents related to an increased injury risk to the handler. At milking, cows were quite easily moved using few interactions. As expected, the cows showed no behavioral signs of stress, fear, or resistance and their heart rate only rose slightly from the baseline (i.e., the average heart rate during an undisturbed period before handling). Moving cows to hoof trimming involved more forceful and gentle interactions compared with moving cows to milking. Furthermore, the cows showed much higher frequencies of behaviors indicative of aversion and fear (e.g., freezing, balking, and resistance), as well as a higher increase in heart rate. The risk of injury to which handlers were exposed also increased when moving cows to hoof trimming rather than to routine milking. Some interactions (such as forceful tactile interactions with an object and pulling a neck strap or halter) appeared to be related to potentially dangerous incidents where the handler was being kicked, head-butted, or run over by a cow. In conclusion, moving cows to hoof trimming resulted in higher frequencies of behaviors indicating fear, more forceful interactions, and increased injury risks to the handler than moving cows to milking. Improving potentially stressful handling procedures (e.g., by better animal handling practices and preparation of cows to cope with such procedures) can increase handler safety, animal welfare, ease of handling, and efficiency. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Day-night variation in heart rate variability changes induced by endotoxaemia in healthy volunteers.
Alamili, M; Rosenberg, J; Gögenur, I
2015-04-01
Morbidity and mortality in response to sepsis may be dependent on clock time for the initiation of sepsis. Endotoxaemia, an experimental model for systemic inflammation, induces alterations in sympatico-vagal balance in the autonomic nervous system (ANS). The activity of sympathetic and parasympathetic activity can be estimated by measuring heart rate variability (HRV). Based on the intimate link between ANS and the inflammatory response, we hypothesized, that HRV changes seen during endotoxaemia would be different based on time of the day the endotoxaemia is initiated. We investigated day/night variation in endotoxaemia-induced changes in HRV. A randomized, crossover study with 12 healthy men (age 18-31) was conducted. Endotoxaemia were induced by lipopolysaccharide (LPS) endotoxin 0.3 ng/kg b.w. in two visits (day visit and night visit). At the day visit, endotoxaemia were induced at 12:00 h, and at the night visit it was induced at 24:00 h. Holter recordings were started 1 h before administration of LPS, and continued for 10 h. Time-domain and frequency-domain parameters of HRV were analysed. A total of nine persons finished the study with valid recordings. Endotoxaemia at both night and day resulted in a significant depression in HRV parameters high-frequency power (HF), low-frequency power (LF), standard deviation of normal-to-normal (NN) intervals, root mean square of successive differences and proportion of NN50 divided by total number of NNs (P<0.001). The ratio LF/HF and mean heart rate significantly increased by endotoxaemia (P<0.001). At night-time endotoxaemia, a more pronounced depression of LF, HF and SDNN (P<0.01) and a more pronounced increase in the ratio of LF/HF and mean heart rate (P<0.01) occurred compared with day-time endotoxaemia. Endotoxaemia induced changes in HRV exhibit a day-night difference. This difference may have clinical consequences in patients with sepsis. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Xiao, Hanguang; Tan, Isabella; Butlin, Mark; Li, Decai; Avolio, Alberto P
2018-03-01
Arterial wave reflection has been shown to have a significant dependence on heart rate (HR). However, the underlying mechanisms inherent in the HR dependency of wave reflection have not been well established. This study aimed to investigate the potential mechanisms and role of arterial viscoelasticity using a 55-segment transmission line model of the human arterial tree combined with a fractional viscoelastic model. At varying degrees of viscoelasticity modeled as fractional order parameter α, reflection magnitude (RM), reflection index (RI), augmentation index (AIx), and a proposed novel normalized reflection coefficient (Γ norm ) were estimated at different HRs from 60 to 100 beats/min with a constant mean flow of 70 ml/s. RM, RI, AIx, and Γ norm at the ascending aorta decreased linearly with increasing HR at all degrees of viscoelasticity. The means ± SD of the HR dependencies of RM, RI, AIx, and Γ norm were -0.042 ± 0.004, -0.018 ± 0.001, -1.93 ± 0.55%, and -0.037 ± 0.002 per 10 beats/min, respectively. There was a significant and nonlinear reduction in RM, RI, and Γ norm with increasing α at all HRs. In addition, HR and α have a more pronounced effect on wave reflection at the aorta than at peripheral arteries. The potential mechanism of the HR dependency of wave reflection was explained by the inverse dependency of the reflection coefficient on frequency, with the harmonics of the pulse waveform moving toward higher frequencies with increasing HR. This HR dependency can be modulated by arterial viscoelasticity. NEW & NOTEWORTHY This in silico study addressed the underlying mechanisms of how heart rate influences arterial wave reflection based on a transmission line model and elucidated the role of arterial viscoelasticity in the dependency of arterial wave reflection on heart rate. This study provides insights into wave reflection as a frequency-dependent phenomenon and demonstrates the validity of using reflection magnitude and reflection index as wave reflection indexes.
Three Weeks of Overload Training Increases Resting Muscle Sympathetic Activity.
Coates, Alexandra M; Incognito, Anthony V; Seed, Jeremy D; Doherty, Connor J; Millar, Philip J; Burr, Jamie F
2018-05-01
Overload training is hypothesized to alter autonomic regulation, although interpretations using indirect measures of heart rate variability are conflicting. The aim of the present study was to examine the effects of overload training on muscle sympathetic nerve activity (MSNA), a direct measure of central sympathetic outflow, in recreational endurance athletes. Measurements of heart rate variability, cardiac baroreflex sensitivity (BRS), MSNA (microneurography), and sympathetic BRS were obtained in 17 healthy triathletes and cyclists after 1 wk of reduced training (baseline) and again after 3 wk of either regular (n = 7) or overload (n = 10) training. After training, the changes (Δ) in peak power output (10 ± 10 vs -12 ± 9 W, P < 0.001), maximal heart rate (-2 ± 4 vs -8 ± 3 bpm, P = 0.006), heart rate variability (SD of normal-to-normal intervals, 27 ± 31 vs -3 ± 25 ms; P = 0.04), and cardiac BRS (7 ± 6 vs -2 ± 8 ms·mm Hg, P = 0.02) differed between the control and overload groups. The change in MSNA burst frequency (-2 ± 2 vs 4 ± 5 bursts per minute, P = 0.02) differed between groups. Across all participants, the changes in resting MSNA and peak power output were correlated negatively (r = -0.51, P = 0.04). No between-group differences in resting heart rate or blood pressure were observed (all P > 0.05). Overload training increased MSNA and attenuated increases in cardiac BRS and heart rate variability observed with regular training. These results support neural adaptations after overload training and suggest that increased central sympathetic outflow may be linked with decreased exercise performance.
A new technique for simultaneous monitoring of electrocardiogram and walking cadence
NASA Technical Reports Server (NTRS)
Hausdorff, J. M.; Forman, D. E.; Pilgrim, D. M.; Rigney, D. R.; Wei, J. Y.; Goldberger, A. L. (Principal Investigator)
1992-01-01
A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).
'Athlete's heart' in prepubertal children.
Rowland, T W; Delaney, B C; Siconolfi, S F
1987-05-01
Bradycardia, cardiomegaly, heart murmurs, and ECG changes are typically observed in adult endurance athletes, but frequency of such changes among children involved in sports training is unclear. Pediatricians need to be aware of whether these features of the "athlete's heart" occur in their patients, because such features may mimic those of cardiac disease. Fourteen prepubertal competitive male swimmers were evaluated by physical examination, ECG and echocardiogram, and findings were compared to those of a group of active but nontrained control boys. Lower resting heart rates and echocardiographic manifestations of chronic left ventricular volume overload were observed among the swimmers. These changes were not manifest on physical examination, however, and no significant ECG alterations were identified among the athletes. These findings indicate that, although features of the athlete's heart are present in children involved in endurance training, seldom will these findings simulate heart disease or be apparent on routine clinical examination.
Stewart, J M
2000-02-01
Invasive arterial monitoring alters autonomic tone. The effects of intravenous (i.v.) insertion are less clear. The author assessed the effects of i.v. insertion on autonomic activity in patients aged 11 to 19 years prior to head-up tilt by measuring heart rate, blood pressure, heart rate variability, blood pressure variability, and baroreceptor gain before and after i.v. insertion with continuous electrocardiography and arterial tonometry in patients with orthostatic tachycardia syndrome (OTS, N = 21), in patients who experienced simple fainting (N = 14), and in normal control subjects (N = 6). Five-minute samples were collected after 30 minutes supine. Fifteen minutes after i.v. insertion, data were collected again. These 5-minute samples were also collected in a separate control population without i.v. insertion after 30 minutes supine and again 30 minutes later. This population included 12 patients with OTS, 13 patients who experienced simple fainting, and 6 normal control subjects. Heart rate variability included the mean RR, the standard deviation of the RR interval (SDNN), and the root mean square of successive RR differences (RMSSD). Autoregressive spectral modeling was used. Low-frequency power (LFP, 0.04-0.15 Hz), high-frequency power (HFP, 0.15-0.40 Hz), and total power (TP, 0.01-0.40 Hz) were compared. Blood pressure variability included standard deviation of systolic blood pressure, LFP, and HFP. Baroreceptor gain at low frequency and high frequency was calculated from cross-spectral transfer function magnitudes when coherence was greater than 0.5. In patients with OTS, RR (790 +/- 50 msec), SDNN (54 +/- 6 msec), RMSSD (55 +/- 5 msec), LFP (422 +/- 200 ms2/Hz), HFP (846 +/- 400 ms2/Hz), and TP (1550 +/- 320 ms2/Hz) were less than in patients who experienced simple fainting (RR, 940 +/- 50 msec; SDNN, 84 +/- 10 msec; RMSSD, 91 +/- 7 msec; LFP, 880 +/- 342 ms2/Hz; HFP, 1720 +/- 210 ms2/Hz; and TP, 3228 +/- 490 ms2/Hz) or normal control subjects (RR, 920 +/- 30 msec; SDNN, 110 +/- 29 msec; RMSSD, 120 +/- 16 msec; LFP, 1600 +/- 331 ms2/Hz; HFP, 2700 +/- 526 ms2/Hz; and TP, 5400 +/- 1017 ms2/Hz). Blood pressure and blood pressure variability were not different in any group. Standard deviation, LFP, and HFP were, respectively, 5.24 +/- 0.8 mm Hg, 1.2 +/- 0.2, and 1.5 +/- 0.3 for patients with OTS; 4.6 +/- 0.4 mm Hg, 1.2 +/- 0.2, and 1.4 +/- 0.3 for patients who experienced simple fainting; and 5.55 +/- 1.0 mm Hg, 1.4 +/- 0.2, and 1.6 +/- 0.3 for normal control subjects. Baroreceptor gain at low frequency and high frequency in patients with OTS (16 +/- 4 msec/mm Hg, 17 +/- 5) was comparable to that in patients who experienced simple fainting (33 +/- 4, 32 +/- 3) and that in normal control subjects (31 +/- 8, 37 +/- 9). Heart rate variability differed between patients with OTS and patients who experienced simple fainting or normal control subjects, and blood pressure and blood pressure variability were not different, but no parameter changed after i.v. insertion. There were no differences from the groups that did not receive i.v. insertions. Data suggest, at most, a limited effect of i.v. insertion on autonomic function in adolescents.
Barczyński, M; Tabor, S; Thor, P
1997-01-01
The aim of the present study was both to estimate autonomic nervous system (ANS) function in patients with hyperthyroidism by the heart rate variability (HRV) analysis and to evaluate the impact of pharmacological and surgical treatment on the ANS function. Analysis of the HRV underwent 10 female patients in course of thyreotoxicosis and after reaching full clinical and biochemical euthyroidism, after pharmacological therapy and in month after surgical treatment. The 10 minutes records at rest, in horizontal position were evaluated. The HRV parameters like mean of the heart rate, mean of RR intervals, standard deviation of all normal RR intervals (SDNN), range of the heart rate variability, low frequency (LF), high frequency (HF) components of the heart rate power spectral density and LF/HF ratio were assessed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. The statistical significance (p < 0.05) was found in reduction of range of RR intervals, in increase of LF/HF ratio and in decrease of SDNN in hyperthyroidism in comparison to the control group (151.6/346.8 ms; 2.4/0.74; 24.4/57.2 ms2). In course of pharmacological euthyroidism there were statistically significant (p < 0.05) increase of range of RR intervals, reduction of LF/HF ratio and increase of SDNN in comparison to hyperthyroidism (270/151.6 ms; 0.995/2.4; 39/24.4 ms2). In euthyroidism after surgical treatment all the above parameters kept the similar levels as in pharmacological euthyroidism (no statistical significance for p < 0.05). On the base of the outcomes it was considered that in hyperthyroid patients there is advantage of sympathetic part of ANS over parasympathetic one which is due to sharp reduction of parasympathetic system activity. Pharmacological therapy with thyreostatics normalises balance of ANS to the level of the control group and after surgical treatment the balance keeps the same. Moreover, in the estimation of ANS as important as LF/HF ratio is the mean range of RR intervals.
Ye, Jing-Jhao; Lee, Kuan-Ting; Lin, Jing-Siang; Chuang, Chiung-Cheng
2017-01-01
Continuously monitoring and efficiently managing pain has become an important issue. However, no study has investigated a change in physiological parameters during the process of pain production/relief. This study modeled the process of pain production/relief using ramped thermal stimulation (no pain: 37°C water, process of pain production: a heating rate of 1°C/min, and subject feels pain: water kept at the painful temperature for each subject, with each segment lasting 10 min). In this duration, the variation of the heat rate variability and photoplethysmography-derived parameters was observed. A total of 40 healthy individuals participated: 30 in the trial group (14 males and 16 females with a mean age of 22.5±1.9 years) and 10 in the control group (7 males and 3 females with a mean age of 22.5±1.3 years). The results showed that the numeric rating scale value was 5.03±1.99 when the subjects felt pain, with a temperature of 43.54±1.70°C. Heart rate, R-R interval, low frequency, high frequency, photoplethysmography amplitude, baseline, and autonomic nervous system state showed significant changes during the pain production process, but these changes differed during the period Segment D (painful temperature 10: min). In summary, the study observed that physiological parameters changed qualitatively during the process of pain production and relief and found that the high frequency, low frequency, and photoplethysmography parameters seemed to have different responses in four situations (no pain, pain production, pain experienced, and pain relief). The trends of these variations may be used as references in the clinical setting for continuously observing pain intensity.
The use of heart rate variability in assessing precompetitive stress in high-standard judo athletes.
Morales, J; Garcia, V; García-Massó, X; Salvá, P; Escobar, R; Buscà, B
2013-02-01
The objective of this study is to examine the sensitivity to and changes in heart rate variability (HRV) in stressful situations before judo competitions and to observe the differences among judo athletes according to their competitive standards in both official and unofficial competitions. 24 (10 male and 14 female) national- and international-standard athletes were evaluated. Each participant answered the Revised Competitive State Anxiety Inventory (CSAI-2R) and their HRV was recorded both during an official and unofficial competition. The MANOVA showed significant main effects of the athlete's standard and the type of competition in CSAI-2R, in HRV time domain, in HRV frequency domain and in HRV nonlinear analysis (p<0.05). International-standard judo athletes have lower somatic anxiety, cognitive anxiety, heart rate and low-high frequency ratio than national-standard athletes (p<0.05). International-standard athletes have a higher confidence, mean RR interval, standard deviation of RR, square root of the mean squared difference of successive RR intervals, number of consecutive RR that differ by more than 5 ms, short-term variability, long-term variability, long-range scaling exponents and short-range scaling exponent than national-standard judo athletes. In conclusion, international-standard athletes show less pre-competitive anxiety than the national-standard athletes and HRV analysis is sensitive to changes in pre-competitive anxiety. © Georg Thieme Verlag KG Stuttgart · New York.
Lee, Na Ra; Kim, Soo Byeong; Heo, Hyun; Lee, Yong Heum
2016-10-01
The aim of this study was to compare the influences of manual acupuncture, laser acupuncture, and electromagnetic field stimulation on the autonomic nervous system. We monitored the heart rate variability before and after stimulation to check the influence on the autonomic nervous system. The heart rate variabilities at low frequency (LF; 0.04-0.15 Hz) and high frequency (HF; 0.15-0.4 Hz) were analyzed to acquire LF/HF ratio. Xinshu (BL15) was selected as the stimulation point. Methods included manual acupuncture with a 1-cm depth and laser acupuncture at a wavelength of 660 nm and output power of 50 mW. An electromagnetic field of 2 Hz and 460 gauss (46 mT) was chosen. The LF and the LF/HF ratio were found to be lower in the manual acupuncture and the electromagnetic field groups, but to be higher in the laser acupuncture group. The HF was found to be lower in the laser acupuncture group, but higher in the manual acupuncture and the electromagnetic field groups. In conclusion, we found that manual acupuncture and electromagnetic field stimulation at BL15 activated the parasympathetic nervous system, whereas laser acupuncture at BL15 activated the sympathetic nervous system. Copyright © 2016. Published by Elsevier B.V.
Constantin, Kaytlin; Moline, Rachel L.; Bailey, Heidi N.
2017-01-01
Parents’ ability to regulate their emotions is essential to providing supportive caregiving behaviours when their child is in pain. Extant research focuses on parent self-reported experience or observable behavioural responses. Physiological responding, such as heart rate (HR) and heart rate variability (HRV), is critical to the experience and regulation of emotions and provides a complementary perspective on parent experience; yet, it is scarcely assessed. This pilot study examined parent (n = 25) cardiac response (HR, HRV) at rest (neutral film clip), immediately before the cold pressor task (pre-CPT), and following the CPT (post-CPT). Further, variables that may influence changes in HR and HRV in the context of pediatric pain were investigated, including (1) initial HRV, and (2) parent perception of their child’s typical response to needle procedures. Time-domain (root mean square of successive differences; RMSSD) and frequency-domain (high-frequency heart rate variability; HF-HRV) parameters of HRV were computed. HR and HF-HRV varied as a function of time block. Typical negative responses to needle pain related to higher parental HR and lower HRV at rest. Parents with higher HRV at baseline experienced the greatest decreases in HRV after the CPT. Consequently, considering previous experience with pain and resting HRV levels are relevant to understanding parent physiological responses before and after child pain. PMID:29160828
Sexual dimorphism in the osmopressor response following water ingestion
Mendonca, Goncalo V.; Teodósio, Carolina; Lucena, Rui; Pereira, Fernando D.
2016-01-01
There is conflicting evidence as to whether water drinking elicits a pressor response in healthy young adults. The inclusion of a variable number of women may have contributed to the discrepancies found in past research. Thus, we aimed at exploring whether the osmopressor response follows a sexually dimorphic pattern. In a randomized fashion, 31 healthy adults (16 men; 15 women, aged 18–40 years) ingested 50 and 500 ml of water before completing a resting protocol on two separate days. Arterial blood pressure, heart rate and spectral heart rate variability were measured in the seated position at pre- and post-25 min of water ingestion. Women responded to 500 ml of water with a greater proportion of change in diastolic and mean arterial pressure (MAP) (P<0.05). Conversely, the percent change in systolic blood pressure (SBP) and heart rate was not different between sexes after 500 ml of water. Overall, women demonstrated lower blood pressure, but higher resting heart rate compared with men (P<0.05). In contrast, heart rate variability was similar between sexes before and after ingesting either volume of water. There was a bradycardic effect of water and, irrespectively of sex; this was accompanied by increased high frequency power (HF) (P<0.05). We conclude that women display a greater magnitude of pressor response than men post-water ingestion. Accordingly, we provide direct evidence of sexual dimorphism in the haemodynamic response to water intake in young healthy adults. PMID:27129286
Peri-ictal ECG changes in childhood epilepsy: implications for detection systems.
Jansen, Katrien; Varon, Carolina; Van Huffel, Sabine; Lagae, Lieven
2013-10-01
Early detection of seizures could reduce associated morbidity and mortality and improve the quality of life of patients with epilepsy. In this study, the aim was to investigate whether ictal tachycardia is present in focal and generalized epileptic seizures in children. We sought to predict in which type of seizures tachycardia can be identified before actual seizure onset. Electrocardiogram segments in 80 seizures were analyzed in time and frequency domains before and after the onset of epileptic seizures on EEG. These ECG parameters were analyzed to find the most informative ones that can be used for seizure detection. The algorithm of Leutmezer et al. was used to find the temporal relationship between the change in heart rate and seizure onset. In the time domain, the mean RR shows a significant difference before compared to after onset of the seizure in focal seizures. This can be observed in temporal lobe seizures as well as frontal lobe seizures. Calculation of mean RR interval has a high specificity for detection of ictal heart rate changes. Preictal heart rate changes are observed in 70% of the partial seizures. Ictal heart rate changes are present only in partial seizures in this childhood epilepsy study. The changes can be observed in temporal lobe seizures as well as in frontal lobe seizures. Heart rate changes precede seizure onset in 70% of the focal seizures, making seizure detection and closed-loop systems a possible therapeutic alternative in the population of children with refractory epilepsy. © 2013.
Bilateral hegu acupoints have the same effect on the heart rate variability of the healthy subjects.
Guangjun, Wang; Yuying, Tian; Shuyong, Jia; Wenting, Zhou; Weibo, Zhang
2014-01-01
Background. The specificity of acupuncture points (acupoints) is one of the key concepts in traditional acupuncture theory, but the question of whether there is adequate scientific evidence to prove or disprove specificity has been vigorously debated in recent years. Acupoint laterality is an important aspect of acupoint specificity. Data is particularly scarce regarding the laterality of the same channel, namesake acupoint located on opposite sides of the body. Our previous study results suggest that Neiguan acupoint (PC6) has the laterality. The aim of this study was to investigate whether Hegu (LI4) also has laterality from the perspective of heart rate variability. Methods. A total of twenty-eight healthy female volunteers were recruited for this study and were randomly separated into the group I (n = 14) and the group II (n = 14) according to the register order. In the group I, left LI4 was stimulated in the first epoch and the right LI4 was stimulated in the second epoch. In the group II, right LI4 was stimulated in the first epoch and left LI4 was stimulated in the second epoch. Electrocardiogram was recorded and heart rate variability was analyzed. Results. The results show that there were no significant differences of heart rate variablity between the group I and the group II in the time domain and in the frequency domain. Conclusions. Bilateral Hegu acupoints have the same effect on the heart rate variability of the healthy subjects.
Measuring task-related changes in heart rate variability.
Moses, Ziev B; Luecken, Linda J; Eason, James C
2007-01-01
Small beat-to-beat differences in heart rate are the result of dynamic control of the cardiovascular system by the sympathetic and parasympathetic nervous systems. Heart rate variability (HRV) has been positively correlated with both mental and physical health. While many studies measure HRV under rest conditions, few have measured HRV during stressful situations. We describe an experimental protocol designed to measure baseline, task, and recovery values of HRV as a function of three different types of stressors. These stressors involve an attention task, a cold pressor test, and a videotaped speech presentation. We found a measurable change in heart rate in participants (n=10) during each task (all p's < 0.05). The relative increase or decrease from pre-task heart rate was predicted by task (one-way ANOVA, p= 0.0001). Spectral analysis of HRV during the attention task revealed consistently decreased measures of both high (68+/-7%, mean+/-S.E.) and low (62+/-13%) frequency HRV components as compared to baseline. HRV spectra for the cold pressor and speech tasks revealed no consistent patterns of increase or decrease from baseline measurements. We also found no correlation in reactivity measures between any of our tasks. These findings suggest that each of the tasks in our experimental design elicits a different type of stress response in an individual. Our experimental approach may prove useful to biobehavioral researchers searching for factors that determine individual differences in responses to stress in daily life.
Frequency Dynamics of the First Heart Sound
NASA Astrophysics Data System (ADS)
Wood, John Charles
Cardiac auscultation is a fundamental clinical tool but first heart sound origins and significance remain controversial. Previous clinical studies have implicated resonant vibrations of both the myocardium and the valves. Accordingly, the goals of this thesis were threefold, (1) to characterize the frequency dynamics of the first heart sound, (2) to determine the relative contribution of the myocardium and the valves in determining first heart sound frequency, and (3) to develop new tools for non-stationary signal analysis. A resonant origin for first heart sound generation was tested through two studies in an open-chest canine preparation. Heart sounds were recorded using ultralight acceleration transducers cemented directly to the epicardium. The first heart sound was observed to be non-stationary and multicomponent. The most dominant feature was a powerful, rapidly-rising frequency component that preceded mitral valve closure. Two broadband components were observed; the first coincided with mitral valve closure while the second significantly preceded aortic valve opening. The spatial frequency of left ventricular vibrations was both high and non-stationary which indicated that the left ventricle was not vibrating passively in response to intracardiac pressure fluctuations but suggested instead that the first heart sound is a propagating transient. In the second study, regional myocardial ischemia was induced by left coronary circumflex arterial occlusion. Acceleration transducers were placed on the ischemic and non-ischemic myocardium to determine whether ischemia produced local or global changes in first heart sound amplitude and frequency. The two zones exhibited disparate amplitude and frequency behavior indicating that the first heart sound is not a resonant phenomenon. To objectively quantify the presence and orientation of signal components, Radon transformation of the time -frequency plane was performed and found to have considerable potential for pattern classification. Radon transformation of the Wigner spectrum (Radon-Wigner transform) was derived to be equivalent to dechirping in the time and frequency domains. Based upon this representation, an analogy between time-frequency estimation and computed tomography was drawn. Cohen's class of time-frequency representations was subsequently shown to result from simple changes in reconstruction filtering parameters. Time-varying filtering, adaptive time-frequency transformation and linear signal synthesis were also performed from the Radon-Wigner representation.
Determination of heart rate variability with an electronic stethoscope.
Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M
2013-02-01
Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.
Time-varying analysis of electrodermal activity during exercise
Reljin, Natasa; Mills, Craig; Mills, Ian; Florian, John P.; VanHeest, Jaci L.; Chon, Ki H.
2018-01-01
The electrodermal activity (EDA) is a useful tool for assessing skin sympathetic nervous activity. Using spectral analysis of EDA data at rest, we have previously found that the spectral band which is the most sensitive to central sympathetic control is largely confined to 0.045 to 0.25 Hz. However, the frequency band associated with sympathetic control in EDA has not been studied for exercise conditions. Establishing the band limits more precisely is important to ensure the accuracy and sensitivity of the technique. As exercise intensity increases, it is intuitive that the frequencies associated with the autonomic dynamics should also increase accordingly. Hence, the aim of this study was to examine the appropriate frequency band associated with the sympathetic nervous system in the EDA signal during exercise. Eighteen healthy subjects underwent a sub-maximal exercise test, including a resting period, walking, and running, until achieving 85% of maximum heart rate. Both EDA and ECG data were measured simultaneously for all subjects. The ECG was used to monitor subjects’ instantaneous heart rate, which was used to set the experiment’s end point. We found that the upper bound of the frequency band (Fmax) containing the EDA spectral power significantly shifted to higher frequencies when subjects underwent prolonged low-intensity (Fmax ~ 0.28) and vigorous-intensity exercise (Fmax ~ 0.37 Hz) when compared to the resting condition. In summary, we have found shifting of the sympathetic dynamics to higher frequencies in the EDA signal when subjects undergo physical activity. PMID:29856815
Frequency ranges of heart rate variability related to autonomic nerve activity in the mouse.
Tsai, Meng-Li; Chen, Chien-Chang; Yeh, Chang-Jyi; Chou, Li-Ming; Cheng, Chiung-Hsiang
2012-01-01
Mice have gained more and more attention in recent years and been widely used in transgenic experiments. Although the number of researches on the heart rate variability (HRV) of mice has been gradually increasing, a consensus on the frequency ranges of autonomic modulation has not been established. Therefore, the main purpose of this study was to find a HRV "prototype" for conscious mice in the state of being motionless and breathing regularly (called "genuinely resting"), and to determine the frequency ranges corresponding to the autonomic modulation. Further, whether these frequencies will change when the mice move freely was studied to evaluate the feasibility of the HRV spectrum as an index of the autonomic modulation of mice. The recording sites were specially arranged to simultaneously obtain the electrocardiography and electromyography data to be provided for the use of HRV analysis and motion monitoring, respectively. The states of being motionless and breathing regularly as judged from the electromyography results were selected as a genuine resting state of a conscious mouse. The frequencies related to autonomic modulation of HRV were determined by comparing the spectrum changes before and after blockades of the autonomic tone by different pharmaceutical agents in both the genuine resting state and freely moving states. Our results showed that the HRV of mice is not suitable for indexing sympathetic modulation; however, it is possible to use the spectral power in the frequency range between 0.1 and 1 Hz as an index of parasympathetic modulation.
NASA Astrophysics Data System (ADS)
Tuzhilkin, D. A.; Borodin, A. S.
2017-11-01
The results of the study of variations in the electromagnetic background parameters of the Schumann resonator frequency range and the variability indices of the human heart period during its free activity are presented on the basis of 24-hour synchronous monitoring data. It is shown that the integral evaluation of the conjugacy of the heart rate variability indices from the Schumann resonance parameters is extremely weak. In this case, the differential evaluation of this dependence with separation into characteristic time intervals of the day, characterized by different motor activity of the subjects, becomes significantly higher. The number of volunteers whose conjugacy is characterized by a strong correlation in some cases reaches 35 percent of the sample.
Lee, In-Seon; Preissl, Hubert; Giel, Katrin; Schag, Kathrin; Enck, Paul
2018-01-23
The food-related behavior of functional dyspepsia has been attracting more interest of late. This pilot study aims to provide evidence of the physiological, emotional, and attentional aspects of food processing in functional dyspepsia patients. The study was performed in 15 functional dyspepsia patients and 17 healthy controls after a standard breakfast. We measured autonomic nervous system activity using skin conductance response and heart rate variability, emotional response using facial electromyography, and visual attention using eyetracking during the visual stimuli of food/non-food images. In comparison to healthy controls, functional dyspepsia patients showed a greater craving for food, a decreased intake of food, more dyspeptic symptoms, lower pleasantness rating of food images (particularly of high fat), decreased low frequency/high frequency ratio of heart rate variability, and suppressed total processing time of food images. There were no significant differences of skin conductance response and facial electromyography data between groups. The results suggest that high level cognitive functions rather than autonomic and emotional mechanisms are more liable to function differently in functional dyspepsia patients. Abnormal dietary behavior, reduced subjective rating of pleasantness and visual attention to food should be considered as important pathophysiological characteristics in functional dyspepsia.
Music therapy, emotions and the heart: a pilot study.
Raglio, Alfredo; Oasi, Osmano; Gianotti, Marta; Bellandi, Daniele; Manzoni, Veronica; Goulene, Karine; Imbriani, Chiara; Badiale, Marco Stramba
2012-01-01
The autonomic nervous system plays an important role in the control of cardiac function. It has been suggested that sound and music may have effects on the autonomic control of the heart inducing emotions, concomitantly with the activation of specific brain areas, i.e. the limbic area, and they may exert potential beneficial effects. This study is a prerequisite and defines a methodology to assess the relation between changes in cardiac physiological parameters such as heart rate, QT interval and their variability and the psychological responses to music therapy sessions. We assessed the cardiac physiological parameters and psychological responses to a music therapy session. ECG Holter recordings were performed before, during and after a music therapy session in 8 healthy individuals. The different behaviors of the music therapist and of the subjects have been analyzed with a specific music therapy assessment (Music Therapy Checklist). After the session mean heart rate decreased (p = 0.05), high frequency of heart rate variability tended to be higher and QTc variability tended to be lower. During music therapy session "affect attunements" have been found in all subjects but one. A significant emotional activation was associated to a higher dynamicity and variations of sound-music interactions. Our results may represent the rational basis for larger studies in diferent clinical conditions.
Mizuno, Masaki; Kawada, Toru; Kamiya, Atsunori; Miyamoto, Tadayoshi; Shimizu, Shuji; Shishido, Toshiaki; Smith, Scott A; Sugimachi, Masaru
2011-04-01
We examined the transfer function of autonomic heart rate (HR) control in anesthetized sedentary and exercise-trained (16 wk, treadmill for 1 h, 5 times/wk at 15 m/min and 15-degree grade) rats for comparison to HR variability assessed in the conscious resting state. The transfer function from sympathetic stimulation to HR response was similar between groups (gain, 4.2 ± 1.5 vs. 4.5 ± 1.5 beats·min(-1)·Hz(-1); natural frequency, 0.07 ± 0.01 vs. 0.08 ± 0.01 Hz; damping coefficient, 1.96 ± 0.55 vs. 1.69 ± 0.15; and lag time, 0.7 ± 0.1 vs. 0.6 ± 0.1 s; sedentary vs. exercise trained, respectively, means ± SD). The transfer gain from vagal stimulation to HR response was 6.1 ± 3.0 in the sedentary and 9.7 ± 5.1 beats·min(-1)·Hz(-1) in the exercise-trained group (P = 0.06). The corner frequency (0.11 ± 0.05 vs. 0.17 ± 0.09 Hz) and lag time (0.1 ± 0.1 vs. 0.2 ± 0.1 s) did not differ between groups. When the sympathetic transfer gain was averaged for very-low-frequency and low-frequency bands, no significant group effect was observed. In contrast, when the vagal transfer gain was averaged for very-low-frequency, low-frequency, and high-frequency bands, exercise training produced a significant group effect (P < 0.05 by two-way, repeated-measures ANOVA). These findings suggest that, in the frequency domain, exercise training augments the dynamic HR response to vagal stimulation but not sympathetic stimulation, regardless of the frequency bands.
Lee, Yvonne Yin Leng; Jelinek, Herbert F; McLachlan, Craig S
2017-01-01
A positive correlation between ECG derived QRS duration and heart rate variability (HRV) parameters had previously been reported in young healthy adults. We note this study used a narrow QRS duration range, and did not adjust for systolic blood pressure. Our aims are to investigate associations between systolic blood pressure (SBP), QRS duration and HRV in a rural aging population. A retrospective cross sectional population was obtained from the CSU Diabetes Screening Research Initiative data base where 200 participants had no diabetes or pre-diabetes. SBP data were matched with ECG derived QRS duration and HRV parameters. HRV parameters were calculated from R-R intervals. Resting 12-lead electrocardiograms were obtained from each subject using a Welch Allyn PC-Based ECG system. Pearson correlation analysis revealed no statistically significant associations between HRV parameters and QRS duration. No significant mean differences in HRV parameter subgroups across defined QRS cut-offs were found. SBP > 146 mmHg was associated with increasing QRS durations, however this association disappeared once models were adjusted for age and gender. SBP was also significantly associated with a number of HRV parameters using Pearson correlation analysis, including high frequency (HF) ( p < 0.05), HFln ( p < 0.02), RMSDD ( p < 0.02) and non-linear parameters; ApEN ( p < 0.001) were negatively correlated with increasing SBP while the low frequency to high frequency ratio (LF/HF) increased with increasing SBP ( p < 0.03). Our results do not support associations between ECG derived R-R derived HRV parameters and QRS duration in aging populations. We suggest that ventricular conduction as determined by QRS duration is independent of variations in SA-node heart rate variability.
Ethnic analogies and differences in fetal heart rate variability signal: A retrospective study.
Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Fagioli, Rosa; Di Cresce, Marco; Sacchi, Lucia; Signorini, Maria Gabriella; Campanile, Marta; Martinelli, Pasquale; Magenes, Giovanni
2017-02-01
We aimed to analyze computerized cardiotocographic (cCTG) parameters (including fetal heart rate baseline, short-term variability, Delta, long-term irregularity [LTI], interval index [II], low frequency [LF], movement frequency [MF], high frequency [HF], and approximate entropy [ApEn]) in physiological term pregnancies in order to correlate them with ethnic differences. The clinical meaning of numerical parameters may explain physiological or paraphysiological phenomena that occur in fetuses of different ethnic origins. A total of 696 pregnant women, including 384 from Europe, 246 from sub-Saharan Africa, 45 from South-East Asia, and 21 from South America, were monitored from the 37th to the 41st week of gestation. Statistical analysis was performed with the analysis of variance test, Pearson correlation test and receiver-operator curves (P < 0.05). Our results showed statistically significant differences (P < 0.05) between white and black women for Delta, LTI, LF, MF, HF, and ApEn; between white and Asian women for Delta, LTI, MF, and the LF/(HF + MF) ratio; and between white and Latina women for Delta, LTI, and ApEn. In particular, Delta and LTI performed better in the white group than in the black, Asian, and Latina groups. Instead, LF, MF, HF, and ApEn performed better in the black than in the white group. Our results confirmed the integrity and normal functionality of both central and autonomic nervous system components for all fetuses investigated. Therefore, CTG monitoring should include both linear and nonlinear components of fetal heart rate variability in order to avoid misinterpretations of the CTG trace among ethnic groups. © 2016 Japan Society of Obstetrics and Gynecology.
Stroke as the Initial Manifestation of Atrial Fibrillation: The Framingham Heart Study.
Lubitz, Steven A; Yin, Xiaoyan; McManus, David D; Weng, Lu-Chen; Aparicio, Hugo J; Walkey, Allan J; Rafael Romero, Jose; Kase, Carlos S; Ellinor, Patrick T; Wolf, Philip A; Seshadri, Sudha; Benjamin, Emelia J
2017-02-01
To prevent strokes that may occur as the first manifestation of atrial fibrillation (AF), screening programs have been proposed to identify patients with undiagnosed AF who may be eligible for treatment with anticoagulation. However, the frequency with which patients with AF present with stroke as the initial manifestation of the arrhythmia is unknown. We estimated the frequency with which AF may present as a stroke in 1809 community-based Framingham Heart Study participants with first-detected AF and without previous strokes, by tabulating the frequencies of strokes occurring on the same day, within 30 days before, 90 days before, and 365 days before first-detected AF. Using previously reported AF incidence rates, we estimated the incidence of strokes that may represent the initial manifestation of AF. We observed 87 strokes that occurred ≤1 year before AF detection, corresponding to 1.7% on the same day, 3.4% within 30 days before, 3.7% within 90 days before, and 4.8% ≤1 year before AF detection. We estimated that strokes may present as the initial manifestation of AF at a rate of 2 to 5 per 10 000 person-years, in both men and women. We observed that stroke is an uncommon but measureable presenting feature of AF. Our data imply that emphasizing cost-effectiveness of population-wide AF-screening efforts will be important given the relative infrequency with which stroke represents the initial manifestation of AF. © 2017 American Heart Association, Inc.
Bilgin, Suleyman; Arslan, Evren; Elmas, Onur; Yildiz, Sedat; Colak, Omer H; Bilgin, Gurkan; Koyuncuoglu, Hasan Rifat; Akkus, Selami; Comlekci, Selcuk; Koklukaya, Etem
2015-12-01
Fibromyalgia syndrome (FMS) is identified by widespread musculoskeletal pain, sleep disturbance, nonrestorative sleep, fatigue, morning stiffness and anxiety. Anxiety is very common in Fibromyalgia and generally leads to a misdiagnosis. Self-rated Beck Anxiety Inventory (BAI) and doctor-rated Hamilton Anxiety Inventory (HAM-A) are frequently used by specialists to determine anxiety that accompanies fibromyalgia. However, these semi-quantitative anxiety tests are still subjective as the tests are scored using doctor-rated or self-rated scales. In this study, we investigated the relationship between heart rate variability (HRV) frequency subbands and anxiety tests. The study was conducted with 56 FMS patients and 34 healthy controls. BAI and HAM-A test scores were determined for each participant. ECG signals were then recruited and 71 HRV subbands were obtained from these ECG signals using Wavelet Packet Transform (WPT). The subbands and anxiety tests scores were analyzed and compared using multilayer perceptron neural networks (MLPNN). The results show that a HRV high frequency (HF) subband in the range of 0.15235Hz to 0.40235Hz, is correlated with BAI scores and another HRV HF subband, frequency range of 0.15235Hz to 0.28907Hz is correlated with HAM-A scores. The overall accuracy is 91.11% for HAM-A and 90% for BAI with MLPNN analysis. Doctor-rated or self-rated anxiety tests should be supported with quantitative and more objective methods. Our results show that the HRV parameters will be able to support the anxiety tests in the clinical evaluation of fibromyalgia. In other words, HRV parameters can potentially be used as an auxiliary diagnostic method in conjunction with anxiety tests. Copyright © 2015 Elsevier Ltd. All rights reserved.
Effect of mobile phone radiation on heart rate variability.
Ahamed, V I Thajudin; Karthick, N G; Joseph, Paul K
2008-06-01
The rapid increase in the use of mobile phones (MPs) in recent years has raised the problem of health risk connected with high-frequency electromagnetic fields. There are reports of headache, dizziness, numbness in the thigh, and heaviness in the chest among MP users. This paper deals with the neurological effect of electromagnetic fields radiated from MPs, by studies on heart rate variability (HRV) of 14 male volunteers. As heart rate is modulated by the autonomic nervous system, study of HRV can be used for assessing the neurological effect. The parameters used in this study for quantifying the effect on HRV are scaling exponent and sample entropy. The result indicates an increase in both the parameters when MP is kept close to the chest and a decrease when kept close to the head. MP has caused changes in HRV indices and the change varied with its position, but the changes cannot be considered significant as the p values are high.
Schellewald, Vera; Kleinert, Jens; Ellegast, Rolf
2018-09-01
The aim of this study was to investigate the use of two types of dynamic workstations (Deskbike, activeLife Trainer) and their effects on physiological activation in an occupational setting. 30 employees were given access to the devices for 28 days. Frequency and duration of borrowing and use was recorded by a Chipcard-system. Physiological activation (energy expenditure, heart rate) while working in a seated position and using the workstations was measured with the activity tracker Fitbit Charge HR. Participants used dynamic workstations on 40% of their working days for an average of 54.3 ± 23.9 min per day. Energy expenditure and heart rate increased significantly while using the workstations compared to working seated. The Deskbike was used more frequently and resulted in greater heart rate elevation. Both types of dynamic workstations were used by the employees and had positive effects on physiological activation. The implementation of either type can be recommended. Copyright © 2018 Elsevier Ltd. All rights reserved.
Heart rate variability based on risk stratification for type 2 diabetes mellitus.
Silva-E-Oliveira, Julia; Amélio, Pâmela Marina; Abranches, Isabela Lopes Laguardia; Damasceno, Dênis Derly; Furtado, Fabianne
2017-01-01
To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability. Avaliar a variabilidade da frequência cardíaca em adultos com diferentes níveis de risco para diabetes mellitus tipo 2. O grau de risco para diabetes mellitus tipo 2 de 130 participantes (41 homens) foi avaliado pelo questionário Finnish Diabetes Risk Score. Os participantes foram classificados em baixo risco (n=26), risco levemente elevado (n=41), risco moderado (n=27) e alto risco (n=32). Para medir a variabilidade da frequência cardíaca, utilizou-se o frequencímetro Polar S810i® para obter séries de intervalo RR para cada indivíduo, em repouso, durante 5 minutos; posteriormente, realizou-se análise por meio de índices lineares e não-lineares. O grupo com maior risco para diabetes mellitus tipo 2 teve uma diminuição significante nos índices lineares e não-lineares da variabilidade da frequência cardíaca. Os resultados apontam que indivíduos com risco alto para diabetes mellitus tipo 2 tem menor variabilidade da frequência cardíaca. To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability.
Lebwohl, Benjamin; Cao, Yin; Zong, Geng; Hu, Frank B; Green, Peter H R; Neugut, Alfred I; Rimm, Eric B; Sampson, Laura; Dougherty, Lauren W; Giovannucci, Edward; Willett, Walter C; Sun, Qi; Chan, Andrew T
2017-05-02
Objective To examine the association of long term intake of gluten with the development of incident coronary heart disease. Design Prospective cohort study. Setting and participants 64 714 women in the Nurses' Health Study and 45 303 men in the Health Professionals Follow-up Study without a history of coronary heart disease who completed a 131 item semiquantitative food frequency questionnaire in 1986 that was updated every four years through 2010. Exposure Consumption of gluten, estimated from food frequency questionnaires. Main outcome measure Development of coronary heart disease (fatal or non-fatal myocardial infarction). Results During 26 years of follow-up encompassing 2 273 931 person years, 2431 women and 4098 men developed coronary heart disease. Compared with participants in the lowest fifth of gluten intake, who had a coronary heart disease incidence rate of 352 per 100 000 person years, those in the highest fifth had a rate of 277 events per 100 000 person years, leading to an unadjusted rate difference of 75 (95% confidence interval 51 to 98) fewer cases of coronary heart disease per 100 000 person years. After adjustment for known risk factors, participants in the highest fifth of estimated gluten intake had a multivariable hazard ratio for coronary heart disease of 0.95 (95% confidence interval 0.88 to 1.02; P for trend=0.29). After additional adjustment for intake of whole grains (leaving the remaining variance of gluten corresponding to refined grains), the multivariate hazard ratio was 1.00 (0.92 to 1.09; P for trend=0.77). In contrast, after additional adjustment for intake of refined grains (leaving the variance of gluten intake correlating with whole grain intake), estimated gluten consumption was associated with a lower risk of coronary heart disease (multivariate hazard ratio 0.85, 0.77 to 0.93; P for trend=0.002). Conclusion Long term dietary intake of gluten was not associated with risk of coronary heart disease. However, the avoidance of gluten may result in reduced consumption of beneficial whole grains, which may affect cardiovascular risk. The promotion of gluten-free diets among people without celiac disease should not be encouraged. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Losartan corrects abnormal frequency response of renal vasculature in congestive heart failure.
DiBona, Gerald F; Sawin, Linda L
2003-11-01
In congestive heart failure, renal blood flow is decreased and renal vascular resistance is increased in a setting of increased activity of both the sympathetic nervous and renin-angiotensin systems. The renal vasoconstrictor response to renal nerve stimulation is enhanced. This is associated with an abnormality in the low-pass filter function of the renal vasculature wherein higher frequencies (> or =0.01 Hz) within renal sympathetic nerve activity are not normally attenuated and are passed into the renal blood flow signal. This study tested the hypothesis that excess angiotensin II action mediates the abnormal frequency response characteristics of the renal vasculature in congestive heart failure. In anesthetized rats, the renal vasoconstrictor response to graded frequency renal nerve stimulation was significantly greater in congestive heart failure than in control rats. Losartan attenuated the renal vasoconstrictor response to a significantly greater degree in congestive heart failure than in control rats. In control rats, the frequency response of the renal vasculature was that of a first order (-20 dB/frequency decade) low-pass filter with a corner frequency (-3 dB, 30% attenuation) of 0.002 Hz and 97% attenuation (-30 dB) at > or =0.1 Hz. In congestive heart failure rats, attenuation did not exceed 45% (-5 dB) over the frequency range of 0.001-0.6 Hz. The frequency response of the renal vasculature was not affected by losartan treatment in control rats but was completely restored to normal by losartan treatment in congestive heart failure rats. The enhanced renal vasoconstrictor response to renal nerve stimulation and the associated abnormality in the frequency response characteristics of the renal vasculature seen in congestive heart failure are mediated by the action of angiotensin II on renal angiotensin II AT1 receptors.
Short-term heart rate variability (HRV) in healthy dogs.
Bogucki, Sz; Noszczyk-Nowak, A
2015-01-01
Heart rate variability (HRV) is a well established mortality risk factor in both healthy dogs and those with heart failure. While the standards for short-term HRV analysis have been developed in humans, only reference values for HRV parameters determined from 24-hour ECG have been proposed in dogs. The aim of this study was to develop the reference values for short-term HRV parameters in a group of 50 healthy dogs of various breeds (age 4.86 ± 2.74 years, body weight 12.2 ± 3.88 kg). The ECG was recorded continuously for at least 180 min in a dark and quiet room. All electrocardiograms were inspected automatically and manually to eliminate atrial or ventricular premature complexes. Signals were transformed into a spectrum using the fast Fourier transform. The HRV parameters were measured at fixed times from 60-min ECG segments. The following time-domain parameters (ms) were analyzed: mean NN, SDNN, SDANN, SDNN index, rMSSD and pNN50. Moreover, frequency-domain parameters (Hz) were determined, including very low frequency (VLF), low frequency (LF) and high frequency (HF) components, total power (TP) and the LF/HF ratio. The results (means ± SD) were as follows: mean NN = 677.68 ± 126.89; SDNN = 208.86 ± 77.1; SDANN = 70.75 ± 30.9; SDNN index = 190.75 ± 76.12; rMSSD = 259 ± 120.17, pNN50 = 71.84 ± 13.96; VLF = 984.96 ± 327.7; LF = 1501.24 ± 736.32; HF = 5845.45 ± 2914.20; TP = 11065.31 ± 3866.87; LF/HF = 0.28 ± 0.11.
Sympathomimetic Effects of Acute E-Cigarette Use: Role of Nicotine and Non-Nicotine Constituents.
Moheimani, Roya S; Bhetraratana, May; Peters, Kacey M; Yang, Benjamin K; Yin, Fen; Gornbein, Jeffrey; Araujo, Jesus A; Middlekauff, Holly R
2017-09-20
Chronic electronic (e) cigarette users have increased resting cardiac sympathetic nerve activity and increased susceptibility to oxidative stress. The purpose of the present study is to determine the role of nicotine versus non-nicotine constituents in e-cigarette emissions in causing these pathologies in otherwise healthy humans. Thirty-three healthy volunteers who were not current e-cigarette or tobacco cigarette smokers were studied. On different days, each participant used an e-cigarette with nicotine, an e-cigarette without nicotine, or a sham control. Cardiac sympathetic nerve activity was determined by heart rate variability, and susceptibility to oxidative stress was determined by plasma paraoxonase activity. Following exposure to the e-cigarette with nicotine, but not to the e-cigarette without nicotine or the sham control, there was a significant and marked shift in cardiac sympathovagal balance towards sympathetic predominance. The decrease in high-frequency component and the increases in the low-frequency component and the low-frequency to high-frequency ratio were significantly greater following exposure to the e-cigarette with nicotine compared with exposure to the e-cigarette without nicotine or to sham control. Oxidative stress, as estimated by plasma paraoxonase, did not increase following any of the 3 exposures. The acute sympathomimetic effect of e-cigarettes is attributable to the inhaled nicotine, not to non-nicotine constituents in e-cigarette aerosol, recapitulating the same heart rate variability pattern associated with increased cardiac risk in multiple populations with and without known cardiac disease. Evidence of oxidative stress, as estimated by plasma paraoxonase activity, was not uncovered following acute e-cigarette exposure. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Leung, Ting-Kai; Kuo, Chia-Hua; Lee, Chi-Ming; Kan, Nai-Wen; Hou, Chien-Wen
2013-12-31
Previous biomolecular and animal studies have shown that a room-temperature far-infrared-rayemitting ceramic material (bioceramic) demonstrates physical-biological effects, including the normalization of psychologically induced stress-conditioned elevated heart rate in animals. In this clinical study, the Harvard step test, the resting metabolic rate (RMR) assessment and the treadmill running test were conducted to evaluate possible physiological effects of the bioceramic material in human patients. The analysis of heart rate variability (HRV) during the Harvard step test indicated that the bioceramic material significantly increased the high-frequency (HF) power spectrum. In addition, the results of RMR analysis suggest that the bioceramic material reduced oxygen consumption (VO2). Our results demonstrate that the bioceramic material has the tendency to stimulate parasympathetic responses, which may reduce resting energy expenditure and improve cardiorespiratory recovery following exercise.
Fundamentals of Zoological Scaling.
ERIC Educational Resources Information Center
Lin, Herbert
1982-01-01
The following animal characteristics are considered to determine how properties and characteristics of various systems change with system size (scaling): skeletal weight, speed of running, height and range of jumping, food consumption, heart rate, lifetime, locomotive efficiency, frequency of wing-flapping, and maximum sizes of flying and hovering…
Kubios HRV--heart rate variability analysis software.
Tarvainen, Mika P; Niskanen, Juha-Pekka; Lipponen, Jukka A; Ranta-Aho, Perttu O; Karjalainen, Pasi A
2014-01-01
Kubios HRV is an advanced and easy to use software for heart rate variability (HRV) analysis. The software supports several input data formats for electrocardiogram (ECG) data and beat-to-beat RR interval data. It includes an adaptive QRS detection algorithm and tools for artifact correction, trend removal and analysis sample selection. The software computes all the commonly used time-domain and frequency-domain HRV parameters and several nonlinear parameters. There are several adjustable analysis settings through which the analysis methods can be optimized for different data. The ECG derived respiratory frequency is also computed, which is important for reliable interpretation of the analysis results. The analysis results can be saved as an ASCII text file (easy to import into MS Excel or SPSS), Matlab MAT-file, or as a PDF report. The software is easy to use through its compact graphical user interface. The software is available free of charge for Windows and Linux operating systems at http://kubios.uef.fi. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Gender Differences in Autonomic Control of the Cardiovascular System.
Pothineni, Naga Venkata; Shirazi, Lily F; Mehta, Jawahar L
2016-01-01
The autonomic nervous system (ANS) is a key regulator of the cardiovascular system. The two arms of the ANS, sympathetic and parasympathetic (vagal) have co-regulatory effects on cardiac homeostasis. ANS modulation and dysfunction are also believed to affect various cardiac disease states. Over the past decade, there has been increasing evidence suggesting gender differences in ANS activity. In multiple previous studies, ANS activity was primarily assessed using heart rate variability, muscle sympathetic nerve activity, coronary blood flow velocity, and plasma biomarkers. Heart rate variability is a non-invasive measure, which can be analyzed in terms of low frequency and high frequency oscillations, which indicate the sympathetic and parasympathetic tone, respectively. These measures have been studied between women and men in states of rest and stress, and in cardiac disease. Studies support the concept of a significant gender difference in ANS activity. Further studies are indicated to elucidate specific differences and mechanisms, which could guide targeted therapy of various cardiovascular disease states.
Organisational injustice and impaired cardiovascular regulation among female employees
Elovainio, M; Kivimäki, M; Puttonen, S; Lindholm, H; Pohjonen, T; Sinervo, T
2006-01-01
Objectives To examine the relation between perceived organisational justice and cardiovascular reactivity in women. Methods The participants were 57 women working in long term care homes. Heart rate variability and systolic arterial pressure variability were used as markers of autonomic function. Organisational justice was measured using the scale of Moorman. Data on other risk factors were also collected. Results Results from logistic regression models showed that the risk for increased low frequency band systolic arterial pressure variability was 3.8–5.8 times higher in employees with low justice than in employees with high justice. Low perceived justice was also related to an 80% excess risk of reduced high frequency heart rate variability compared to high perceived justice, but this association was not statistically significant. Conclusions These findings are consistent with the hypothesis that cardiac dysregulation is one stress mechanism through which a low perceived justice of decision making procedures and interpersonal treatment increases the risk of health problems in personnel. PMID:16421394
Fermi-Pasta-Ulam auto recurrence in the description of the electrical activity of the heart.
Novopashin, M A; Shmid, A V; Berezin, A A
2017-04-01
The authors proposed and mathematically described model of a new type of the Fermi-Pasta-Ulam recurrence (the FPU auto recurrence) and hypothesized an adequate description of the heart's electrical dynamics within the observed phenomenon. The dynamics of the FPU auto recurrence making appropriate electrical dynamics of the normal functioning of the heart in the form of an electrocardiogram (ECG) was obtained by a computer model study. The model solutions in the form of the FPU auto recurrence - ECG Fourier spectrum were evaluated for resistance to external disturbances in the form of random effects, as well as periodic perturbation at a frequency close to the heart beating rate of about 1Hz. In addition, in order to simulate the dynamics of myocardial infarction model, studied the effect of the surface area of the myocardium on the stability and shape of the auto recurrence - ECG spectrum. It has been found that the intense external disturbing periodic impacts at a frequency of about 1Hz lead to a sharp disturbance spectrum shape FPU auto recurrence - ECG structure. In addition, the decrease in the surface of the myocardium by 50% in the model led to the destruction of structures of the auto recurrence - ECG, which corresponds to the state of atrial myocardium. Research models have revealed a hypothetical basis of coronary heart disease in the form of increasing the energy of high-frequency harmonics spectrum of the auto recurrence by reducing the energy of low-frequency harmonic spectrum of the auto recurrence, which ultimately leads to a sharp decrease in myocardial contractility. In order to test the hypothesis has been studied more than 20,000 ECGs both healthy people and patients with cardiovascular disease. As a result of these studies, it was found that the dynamics of the electrical activity of normal functioning of the heart can be interpreted by the display of the detected by authors the FPU auto recurrence, and coronary heart disease is a violation of the energy ratio between the low and high frequency harmonics of the FPU auto recurrence Fourier spectrum equal to the ECG spectrum. Thus, the hypothesis has been confirmed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Goffeng, Elisabeth M; Nordby, Karl-Christian; Tarvainen, Mika P; Järvelin-Pasanen, Susanna; Wagstaff, Anthony; Goffeng, Lars Ole; Bugge, Merete; Skare, Øivind; Sigstad Lie, Jenny-Anne
2018-04-07
The aim of this study was to investigate fluctuations in heart rate variability (HRV), which reflect autonomic nervous system (ANS) function and potential psychological and physical strain, among 24 health care workers during work and sleep during four consecutive extended work shifts. Data included 24/36/12 h of HRV measurements, two logbooks, and a questionnaire. A cross-shift/cross-week design was applied. HRV was measured during work, leisure time, and sleep. The HRV data included time-domain [mean RR, SD of normal to normal R-R intervals (SDNN), and root mean square of the successive differences (RMSSD)] and frequency-domain [low frequency (LF)/high frequency (HF) ratio] parameters. HRV parameters revealed significant differences among work, leisure time, and sleep. Mean RR, RMSSD, and SDNN values were lower and the LF/HF ratio was higher on the first versus last day of the work period; however, the differences were most prominent in the morning hours. The results indicate higher levels of cardiovascular stress on the first versus fourth day of the working period, and measurements at night indicate a satisfactory recovery from the extended shifts.
Byrd, Dana L.; Reuther, Erin T.; McNamara, Joseph P. H.; DeLucca, Teri L.; Berg, William K.
2015-01-01
The current study examines similarity or disparity of a frontally mediated physiological response of mental effort among multiple executive functioning tasks between children and adults. Task performance and phasic heart rate variability (HRV) were recorded in children (6 to 10 years old) and adults in an examination of age differences in executive functioning skills during periods of increased demand. Executive load levels were varied by increasing the difficulty levels of three executive functioning tasks: inhibition (IN), working memory (WM), and planning/problem solving (PL). Behavioral performance decreased in all tasks with increased executive demand in both children and adults. Adults’ phasic high frequency HRV was suppressed during the management of increased IN and WM load. Children’s phasic HRV was suppressed during the management of moderate WM load. HRV was not suppressed during either children’s or adults’ increasing load during the PL task. High frequency phasic HRV may be most sensitive to executive function tasks that have a time-response pressure, and simply requiring performance on a self-paced task requiring frontal lobe activation may not be enough to generate HRV responsitivity to increasing demand. PMID:25798113
Thermoregulatory responses of rats exposed to 9. 3-GHz radio-frequency radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frei, M.R.; Jauchem, J.R.; Heinmets, F.
1987-10-15
Ketamine-anesthetized Sprague-Dawley rats were exposed in H orientation to far-field 9.3-GHz continuous-wave (CW) and pulsed (2 microseconds 500 pps) radiofrequency radiation (RFR) at average power densities of 30 and 60 mW/sq. cm (whole-body average specific absorption rates of 9.3 and 18.6 W/kg, respectively). Irradiation was conducted to cyclicly increase colonic temperature from 38.5 to 39.5 C. Colonic, tympanic, and subcutaneous temperatures, ECG, blood pressure, and respiratory rate were continuously recorded during experimentation. At both power densities, the subcutaneous and tympanic temperature increases significantly exceeded the colonic temperature increase. At both exposure levels, heart rate increased significantly during irradiation and returnedmore » to baseline when exposure was discontinued. Blood pressure and respiratory rate did not significantly change during irradiation. There were no significant differences between the effects of CW and pulsed RFR exposure. The levels of subcutaneous heating and heart rate change were greater, and the times required to achieve and to recover from a 1 C colonic temperature increase were longer than in previous studies conducted at 2.8 GHz. Results of these studies indicate that the carrier frequency used during irradiation markedly affects the pattern of heat distribution and the physiological responses of RF-irradiated animals.« less
Musical Auditory Stimulation Influences Heart Rate Autonomic Responses to Endodontic Treatment
Martiniano, Eli Carlos; Monteiro, Larissa Raylane Lucas; Valenti, Vitor E.; Sorpreso, Isabel Cristina Esposito; de Abreu, Luiz Carlos
2017-01-01
We aimed to evaluate the acute effect of musical auditory stimulation on heart rate autonomic regulation during endodontic treatment. The study included 50 subjects from either gender between 18 and 40 years old, diagnosed with irreversible pulpitis or pulp necrosis of the upper front teeth and endodontic treatment indication. HRV was recorded 10 minutes before (T1), during (T2), and immediately (T3 and T4) after endodontic treatment. The volunteers were randomly divided into two equal groups: exposed to music (during T2, T3, and T4) or not. We found no difference regarding salivary cortisol and anxiety score. In the group with musical stimulation heart rate decreased in T3 compared to T1 and mean RR interval increased in T2 and T3 compared to T1. SDNN and TINN indices decreased in T3 compared to T4, the RMSSD and SD1 increased in T4 compared to T1, the SD2 increased compared to T3, and LF (low frequency band) increased in T4 compared to T1 and T3. In the control group, only RMSSD and SD1 increased in T3 compared to T1. Musical auditory stimulation enhanced heart rate autonomic modulation during endodontic treatment. PMID:28182118
The calcium-frequency response in the rat ventricular myocyte: an experimental and modelling study.
Gattoni, Sara; Røe, Åsmund Treu; Frisk, Michael; Louch, William E; Niederer, Steven A; Smith, Nicolas P
2016-08-01
In the majority of species, including humans, increased heart rate increases cardiac contractility. This change is known as the force-frequency response (FFR). The majority of mammals have a positive force-frequency relationship (FFR). In rat the FFR is controversial. We derive a species- and temperature-specific data-driven model of the rat ventricular myocyte. As a measure of the FFR, we test the effects of changes in frequency and extracellular calcium on the calcium-frequency response (CFR) in our model and three altered models. The results show a biphasic peak calcium-frequency response, due to biphasic behaviour of the ryanodine receptor and the combined effect of the rapid calmodulin buffer and the frequency-dependent increase in diastolic calcium. Alterations to the model reveal that inclusion of Ca(2+) /calmodulin-dependent protein kinase II (CAMKII)-mediated L-type channel and transient outward K(+) current activity enhances the positive magnitude calcium-frequency response, and the absence of CAMKII-mediated increase in activity of the sarco/endoplasmic reticulum Ca(2+) -ATPase induces a negative magnitude calcium-frequency response. An increase in heart rate affects the strength of cardiac contraction by altering the Ca(2+) transient as a response to physiological demands. This is described by the force-frequency response (FFR), a change in developed force with pacing frequency. The majority of mammals, including humans, have a positive FFR, and cardiac contraction strength increases with heart rate. However, the rat and mouse are exceptions, with the majority of studies reporting a negative FFR, while others report either a biphasic or a positive FFR. Understanding the differences in the FFR between humans and rats is fundamental to interpreting rat-based experimental findings in the context of human physiology. We have developed a novel model of rat ventricular electrophysiology and calcium dynamics, derived predominantly from experimental data recorded under physiological conditions. As a measure of FFR, we tested the effects of changes in stimulation frequency and extracellular calcium concentration on the simulated Ca(2+) transient characteristics and showed a biphasic peak calcium-frequency relationship, consistent with recent observations of a shift from negative to positive FFR when approaching the rat physiological frequency range. We tested the hypotheses that (1) inhibition of Ca(2+) /calmodulin-dependent protein kinase II (CAMKII)-mediated increase in sarco/endoplasmic reticulum Ca(2+) -ATPase (SERCA) activity, (2) CAMKII modulation of SERCA, L-type channel and transient outward K(+) current activity and (3) Na(+) /K(+) pump dynamics play a significant role in the rat FFR. The results reveal a major role for CAMKII modulation of SERCA in the peak Ca(2+) -frequency response, driven most significantly by the cytosolic calcium buffering system and changes in diastolic Ca(2+) . © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Zena, Lucas A; Leite, Cléo A C; Longhini, Leonardo S; Dias, Daniel P M; da Silva, Glauber S F; Hartzler, Lynn K; Gargaglioni, Luciane H; Bícego, Kênia C
2017-11-23
Beat-to-beat variation in heart rate (f H ) has been used as a tool for elucidating the balance between sympathetic and parasympathetic modulation of the heart. A portion of the temporal changes in f H is evidenced by a respiratory influence (cardiorespiratory interaction) on heart rate variability (HRV) with heartbeats increasing and decreasing within a respiratory cycle. Nevertheless, little is known about respiratory effects on HRV in lower vertebrates. By using frequency domain analysis, we provide the first evidence of a ventilatory component in HRV similar to mammalian respiratory sinus arrhythmia in an amphibian, the toad Rhinella schneideri. Increases in the heartbeats arose synchronously with each lung inflation cycle, an intermittent breathing pattern comprised of a series of successive lung inflations. A well-marked peak in the HRV signal matching lung inflation cycle was verified in toads whenever lung inflation cycles exhibit a regular rhythm. The cardiac beat-to-beat variation evoked at the moment of lung inflation accounts for both vagal and sympathetic influences. This cardiorespiratory interaction may arise from interactions between central and peripheral feedback mechanisms governing cardiorespiratory control and may underlie important cardiorespiratory adjustments for gas exchange improvement especially under extreme conditions like low oxygen availability.
Peak high-frequency HRV and peak alpha frequency higher in PTSD.
Wahbeh, Helané; Oken, Barry S
2013-03-01
Posttraumatic stress disorder (PTSD) is difficult to treat and current PTSD treatments are not effective for all people. Despite limited evidence for its efficacy, some clinicians have implemented biofeedback for PTSD treatment. As a first step in constructing an effective biofeedback treatment program, we assessed respiration, electroencephalography (EEG) and heart rate variability (HRV) as potential biofeedback parameters for a future clinical trial. This cross-sectional study included 86 veterans; 59 with and 27 without PTSD. Data were collected on EEG measures, HRV, and respiration rate during an attentive resting state. Measures were analyzed to assess sensitivity to PTSD status and the relationship to PTSD symptoms. Peak alpha frequency was higher in the PTSD group (F(1,84) = 6.14, p = 0.01). Peak high-frequency HRV was lower in the PTSD group (F(2,78) = 26.5, p < 0.00005) when adjusting for respiration rate. All other EEG and HRV measures and respiration were not different between groups. Peak high-frequency HRV and peak alpha frequency are sensitive to PTSD status and may be potential biofeedback parameters for future PTSD clinical trials.
Peak High-Frequency HRV and Peak Alpha Frequency Higher in PTSD
Oken, Barry S.
2012-01-01
Posttraumatic stress disorder (PTSD) is difficult to treat and current PTSD treatments are not effective for all people. Despite limited evidence for its efficacy, some clinicians have implemented biofeedback for PTSD treatment. As a first step in constructing an effective biofeedback treatment program, we assessed respiration, electroencephalography (EEG) and heart rate variability (HRV) as potential biofeedback parameters for a future clinical trial. This cross-sectional study included 86 veterans; 59 with and 27 without PTSD. Data were collected on EEG measures, HRV, and respiration rate during an attentive resting state. Measures were analyzed to assess sensitivity to PTSD status and the relationship to PTSD symptoms. Peak alpha frequency was higher in the PTSD group (F(1,84) = 6.14, p = 0.01). Peak high-frequency HRV was lower in the PTSD group (F(2,78) = 26.5, p<0.00005) when adjusting for respiration rate. All other EEG and HRV measures and respiration were not different between groups. Peak high-frequency HRV and peak alpha frequency are sensitive to PTSD status and may be potential biofeedback parameters for future PTSD clinical trials. PMID:23178990
Stephenson, Elizabeth A; Collins, Kathryn K; Dubin, Anne M; Epstein, Michael R; Hamilton, Robert M; Kertesz, Naomi J; Alexander, Mark E; Cecchin, Frank; Triedman, John K; Walsh, Edward P; Berul, Charles I
2002-10-01
Recent studies in adult populations have revealed seasonal variation in the frequency of acute cardiovascular events, including life-threatening arrhythmias, demonstrating increased events during winter and early spring. Trends in the time of day that arrhythmias occur also were noted. We sought to establish whether pediatric and young adult congenital heart disease implantable cardioverter defibrillator (ICD) recipients have circadian or seasonal variability in shock frequency, similar to adult populations. Data from ICD patients at six pediatric centers in North America were analyzed to assess the timing of life-threatening arrhythmias. The populations consisted of children and adults with congenital heart disease and ICDs placed for malignant arrhythmias. Data were considered in 46 patients who received appropriate therapy (total 139 episodes) for ventricular tachycardia or ventricular fibrillation. Multiple variables were analyzed, including time of day, day of week, and month of year. In contrast to previously studied adult patients, fewer events occurred in the early morning (7.5%), with the most therapies occurring between 6 P.M. and midnight (35%). An increased frequency of therapies was observed in the fall and winter (September-January), representing 60% of all appropriate shocks. Unlike adult populations, Mondays did not have an increased frequency of malignant arrhythmias. Pediatric and adult congenital heart disease populations have moderate seasonal and 24-hour variation in ICD event rate, with some distinctly different peaks than those seen in typical adult ICD populations. These findings suggest circadian variation in arrhythmia vulnerability that may differ from conventional occupational, physical, or emotional stressors. (J Cardiovasc Electrophysiol, Vol. 13, pp.
Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor
NASA Technical Reports Server (NTRS)
Zuckerwar, A. J.; Pretlow, R. A.; Stoughton, J. W.; Baker, D. A.
1993-01-01
A piezopolymer pressure sensor has been developed for service in a portable fetal heart rate monitor, which will permit an expectant mother to perform the fetal nonstress test, a standard predelivery test, in her home. Several sensors are mounted in an array on a belt worn by the mother. The sensor design conforms to the distinctive features of the fetal heart tone, namely, the acoustic signature, frequency spectrum, signal amplitude, and localization. The components of a sensor serve to fulfill five functions: signal detection, acceleration cancellation, acoustical isolation, electrical shielding, and electrical isolation of the mother. A theoretical analysis of the sensor response yields a numerical value for the sensor sensitivity, which is compared to experiment in an in vitro sensor calibration. Finally, an in vivo test on patients within the last six weeks of term reveals that nonstress test recordings from the acoustic monitor compare well with those obtained from conventional ultrasound.
Imamura, Teruhiko; Nitta, Daisuke; Kinugawa, Koichiro
2017-01-05
Adaptive servo-ventilation (ASV) therapy is a recent non-invasive positive pressure ventilation therapy that was developed for patients with heart failure (HF) refractory to optimal medical therapy. However, it is likely that ASV therapy at relatively higher pressure setting worsens some of the patients' prognosis compared with optimal medical therapy. Therefore, identification of optimal pressure settings of ASV therapy is warranted. We present the case of a 42-year-old male with HF, which was caused by dilated cardiomyopathy, who was admitted to our institution for evaluating his eligibility for heart transplantation. To identify the optimal pressure setting [peak end-expiratory pressure (PEEP) ramp test], we performed an ASV support test, during which the PEEP settings were set at levels ranging from 4 to 8 mmHg, and a heart rate variability (HRV) analysis using the MemCalc power spectral density method. Clinical parameters varied dramatically during the PEEP ramp test. Over incremental PEEP levels, pulmonary capillary wedge pressure, cardiac index and high-frequency level (reflecting parasympathetic activity) decreased; however, the low-frequency level increased along with increase in plasma noradrenaline concentrations. An inappropriately high PEEP setting may stimulate sympathetic nerve activity accompanied by decreased cardiac output. This was the first report on the PEEP ramp test during ASV therapy. Further research is warranted to determine whether use of optimal pressure settings using HRV analyses may improve the long-term prognosis of such patients.
An Overview of Heart Rate Variability Metrics and Norms
Shaffer, Fred; Ginsberg, J. P.
2017-01-01
Healthy biological systems exhibit complex patterns of variability that can be described by mathematical chaos. Heart rate variability (HRV) consists of changes in the time intervals between consecutive heartbeats called interbeat intervals (IBIs). A healthy heart is not a metronome. The oscillations of a healthy heart are complex and constantly changing, which allow the cardiovascular system to rapidly adjust to sudden physical and psychological challenges to homeostasis. This article briefly reviews current perspectives on the mechanisms that generate 24 h, short-term (~5 min), and ultra-short-term (<5 min) HRV, the importance of HRV, and its implications for health and performance. The authors provide an overview of widely-used HRV time-domain, frequency-domain, and non-linear metrics. Time-domain indices quantify the amount of HRV observed during monitoring periods that may range from ~2 min to 24 h. Frequency-domain values calculate the absolute or relative amount of signal energy within component bands. Non-linear measurements quantify the unpredictability and complexity of a series of IBIs. The authors survey published normative values for clinical, healthy, and optimal performance populations. They stress the importance of measurement context, including recording period length, subject age, and sex, on baseline HRV values. They caution that 24 h, short-term, and ultra-short-term normative values are not interchangeable. They encourage professionals to supplement published norms with findings from their own specialized populations. Finally, the authors provide an overview of HRV assessment strategies for clinical and optimal performance interventions. PMID:29034226
Her, Keun; Ahn, Chi Bum; Park, Sung Min; Choi, Seong Wook
2015-03-21
Patients who develop critical arrhythmia during left ventricular assist device (LVAD) perfusion have a low survival rate. For diagnosis of unexpected heart abnormalities, new heart-monitoring methods are required for patients supported by LVAD perfusion. Ventricular electrocardiography using electrodes implanted in the ventricle to detect heart contractions is unsuitable if the heart is abnormal. Left ventricular impedance (LVI) is useful for monitoring heart movement but does not show abnormal action potential in the heart muscle. To detect detailed abnormal heart conditions, we obtained ventricular electrocardiograms (v-ECGs) and LVI simultaneously in porcine models connected to LVADs. In the porcine models, electrodes were set on the heart apex and ascending aorta for real-time measurements of v-ECGs and LVI. As the carrier current frequency of the LVI was adjusted to 30 kHz, it was easily derived from the original v-ECG signal by using a high-pass filter (cutoff: 10 kHz). In addition, v-ECGs with a frequency band of 0.1 - 120 Hz were easily derived using a low-pass filter. Simultaneous v-ECG and LVI data were compared to detect heart volume changes during the Q-T period when the heart contracted. A new real-time algorithm for comparison of v-ECGs and LVI determined whether the porcine heartbeats were normal or abnormal. Several abnormal heartbeats were detected using the LVADs operating in asynchronous mode, most of which were premature ventricle contractions (PVCs). To evaluate the accuracy of the new method, the results obtained were compared to normal ECG data and cardiac output measured simultaneously using commercial devices. The new method provided more accurate detection of abnormal heart movements. This method can be used for various heart diseases, even those in which the cardiac output is heavily affected by LVAD operation.
[Effects of long-term Tai Ji Quan exercise on automatic nervous modulation in the elderly].
Guo, Feng
2015-03-01
To examine the effects of long-term Tai Ji Quan (Chinnese Traditional Exercise) on automatic nervous modulation in the elders. The 18 subjects from Tai Ji Quan exercise class in Liaoning University of Retired Veteran Cadres were assigned into long-term Tai Ji Quan exercise group including 10 subjects and novice group including 8 subjects. Electrocardiography, respiratory and blood pressure data were collected on the following time points: at rest before Tai Ji Qhuan exercise and 30 min or 60 min after Tai Ji Quan exercise. The subjects at rest state in the long-term Tai Ji Quan exercise group showed higher than the subjects in the novice group in resperitory rate (RR), standard deviations of normal to normal intervals (SDNN), total power (TP), low frequency power (LFP), high frequency power (HFP), normalized high frequency power (nHFP), but lower in LFP/HFP, systolic and diastolic blood pressure, and heart rate. At rest state the respiratory rate of subjects in long-term Tai Ji Quan exercise group was significantly lower than the novices. After Tai Ji Quan exercise, TP, nHFP, LFP/HFP, heart rate and systolic pressure showed significantly changes, and the change level of Tai Ji Quan on these indices was larger in Tai Ji Quan exercise group than that in the novice group. Long-term Tai Ji Quan exercise can improve vagal modulations, and tend to reduce the sympathetic modulations.
Tsuji, Yoshihiro; Suzuki, Naoki; Hitomi, Yasumasa; Yoshida, Toshiko; Mizuno-Matsumoto, Yuko
2017-06-01
Few studies have focused on the imbalance of the autonomic nervous system in ultrafiltration rate (UFR) subjects without blood pressure variation during maintenance hemodialysis (HD), although the role of autonomic nervous system activation during HD has been proposed to be an important factor for the maintenance of blood pressure. Variations over time in autonomic nervous activity due to differences in UFR were evaluated by measuring heart rate variability (HRV) and approximate entropy (ApEn) in 35 HD patients without blood pressure variations during HD session. The subjects were divided into 3 groups, those with UFR <10 ml/h/kg; ≥10 ml/h/kg but ≤15 ml/h/kg; and >15 ml/h/kg, and Holter ECG was recorded continuously during HD session using frequency analysis of RR intervals. High frequency (HF) and low frequency (LF) spectral components are found to be representative of the parasympathetic nervous system and sympathovagal balance, respectively, with the ratio of LF to HF of HRV providing a measure of sympathetic nervous system. In subjects with UFR >15 ml/h/kg, HF components were significantly lower, and LF/HF and ApEn values were significantly higher, in the latter half of an HD session than before starting HD. Removing water from these subjects would promote sustained sympathetic nervous overactivity. These findings indicate that the UFR during HD needs to be set at ≤15 ml/h/kg.
Qin, Mu; Liu, Xu; Liu, Tao; Wang, Teng; Huang, Congxin
2016-03-09
The regulator of G-protein signaling 5 (Rgs5), which functions as the regulator of G-protein-coupled receptor (GPCR) including muscarinic receptors, has a potential effect on atrial muscarinic receptor-activated IKA ch current. In the present study, hearts of Rgs5 knockout (KO) mice had decreased low-frequency/high-frequency ratio in spectral measures of heart rate variability. Loss of Rgs5 provoked dramatically exaggerated bradycardia and significantly (P<0.05) prolonged sinus nodal recovery time in response to carbachol (0.1 mg/kg, intraperitoneally). Compared to those from wild-type (WT) mice, Langendorff perfused hearts from Rgs5 KO mice had significantly (P<0.01) abbreviated atrial effective refractory periods and increased dominant frequency after administration of acetylcholine (ACh; 1 μmol/L). In addition, whole patch clamp analyses of single atrial myocytes revealed that the ACh-regulated potassium current (IKA ch) was significant increased in the time course of activation and deactivation (P<0.01) in Rgs5 KO, compared to those in WT, mice. To further determine the effect of Rgs5, transgenic mice with cardiac-specific overexpression of human Rgs5 were found to be resistant to ACh-related effects in bradycardia, atrial electrophysiology, and atrial tachyarrhythmia (AT). The results of this study indicate that, as a critical regulator of parasympathetic activation in the heart, Rgs5 prevents vagal-related bradycardia and AT through negatively regulating the IKA ch current. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Soares, Antonio Henrique Germano; Farah, Breno Quintella; Cucato, Gabriel Grizzo; Bastos-Filho, Carmelo José Albanez; Christofaro, Diego Giulliano Destro; Vanderlei, Luiz Carlos Marques; Lima, Aluísio Henrique Rodrigues de Andrade; Ritti-Dias, Raphael Mendes
2016-01-01
To analyze whether the algorithm used for the heart rate variability assessment (fast Fourier transform versus autoregressive methods) influenced its association with cardiovascular risk factors in male adolescents. This cross-sectional study included 1,152 male adolescents (aged 14 to 19 years). The low frequency, high frequency components (absolute numbers and normalized units), low frequency/high frequency ratio, and total power of heart rate variability parameters were obtained using the fast Fourier transform and autoregressive methods, while the adolescents were resting in a supine position. All heart rate variability parameters calculated from both methods were different (p<0.05). However, a low effect size (<0.1) was found for all parameters. The intra-class correlation between methods ranged from 0.96 to 0.99, whereas the variation coefficient ranged from 7.4 to 14.8%. Furthermore, waist circumference was negatively associated with high frequency, and positively associated with low frequency and sympatovagal balance (p<0.001 for both fast Fourier transform and autoregressive methods in all associations). Systolic blood pressure was negatively associated with total power and high frequency, whereas it was positively associated with low frequency and sympatovagal balance (p<0.001 for both fast Fourier transform and autoregressive methods in all associations). Body mass index was negatively associated with high frequency, while it was positively associated with low frequency and sympatovagal balance (p values ranged from <0.001 to 0.007). There are significant differences in heart rate variability parameters obtained with the fast Fourier transform and autoregressive methods in male adolescent; however, these differences are not clinically significant. Analisar se o algoritmo usado para avaliação da variabilidade da frequência cardíaca (transformada rápida de Fourier versus autoregressivo) influencia em sua associação com fatores de risco cardiovascular adolescentes do gênero masculino. Estudo transversal, que incluiu 1.152 adolescentes do gênero masculino (14 a 19 anos). Componentes de baixa e alta frequência (absolutos e unidades normalizadas), razão componente de baixa frequência/componente de alta frequência e poder total da variabilidade da frequência cardíaca foram obtidos em repouso, na posição supina, usando os métodos transformada rápida de Fourier e autorregressivo. Todos os parâmetros da variabilidade da frequência cardíaca para ambos os métodos foram diferentes (p<0,05). Entretanto, um pequeno tamanho do efeito (<0,1) foi observado para todos os parâmetros. Os coeficientes de correlação intraclasse entre os métodos variaram de 0,96 a 0,99, enquanto os coeficientes de variação foram de 7,4 a 14,8%. A circunferência abdominal foi negativamente associada com o componente de alta frequência, e positivamente associada com o componente de baixa frequência e o balanço simpatovagal (p<0,001 para a transformada rápida de Fourier e o autorregressivo em todas as associações). A pressão arterial sistólica foi negativamente associada com o poder total e o componente de alta frequência, enquanto foi positivamente associada com o componente de baixa frequência e o balanço simpatovagal (p<0,001 para a transformada rápida de Fourier e o autorregressivo em todas as associações). O índice de massa corporal foi negativamente associado com o componente de alta frequência, enquanto foi positivamente associado com o componente de baixa frequência e o balanço simpatovagal (valores de p variando de <0,001 a 0,007). Houve diferenças significantes nos parâmetros da variabilidade da frequência cardíaca obtidos com os métodos transformada rápida de Fourier e autorregressivo em adolescentes masculinos, mas essas diferenças não foram clinicamente significativas.
Milicević, Goran
2005-06-01
Heart rate variability (HRV) reflects an influence of autonomic nervous system on heart work. In healthy subjects, ratio between low and high frequency components (LF/HF ratio) of HRV spectra represents a measure of sympatho-vagal balance. The ratio was defined by the authorities as an useful clinical tool, but it seems that it fails to summarise sympatho-vagal balance in a clinical setting. Value of the method was re-evaluated in several categories of cardiac patients. HRV was analysed from 24-hour Holter ECGs in 132 healthy subjects, and 2159 cardiac patients dichotomised by gender, median of age, diagnosis of myocardial infarction or coronary artery surgery, left ventricular systolic function and divided by overall HRV into several categories. In healthy subjects, LF/HF ratio correlated with overall HRV negatively, as expected. The paradoxical finding was obtained in cardiac patients; the lower the overall HRV and the time-domain indices of vagal modulation activity were the lower the LF/HF ratio was. If used as a measure of sympatho-vagal balance, long-term recordings of LF/HF ratio contradict to clinical finding and time-domain HRV indices in cardiac patients. The ratio cannot therefore be used as a reliable marker of autonomic activity in a clinical setting.
Spectral analysis of heart rate variability predicts mortality and instability from vascular injury.
Koko, Kiavash R; McCauley, Brian D; Gaughan, John P; Fromer, Marc W; Nolan, Ryan S; Hagaman, Ashleigh L; Brown, Spencer A; Hazelton, Joshua P
2018-04-01
Spectral analysis of continuous blood pressure and heart rate variability provides a quantitative assessment of autonomic response to hemorrhage. This may reveal markers of mortality as well as endpoints of resuscitation. Fourteen male Yorkshire pigs, ranging in weight from 33 to 36 kg, were included in the analysis. All pigs underwent laparotomy and then sustained a standardized retrohepatic inferior vena cava injury. Animals were then allowed to progress to class 3 hemorrhagic shock and where then treated with abdominal sponge packing followed by 6 h of crystalloid resuscitation. If the pigs survived the 6 h resuscitation, they were in the survival (S) group, otherwise they were placed in the nonsurvival (NS) group. Fast Fourier transformation calculations were used to convert the components of blood pressure and heart rate variability into corresponding frequency classifications. Autonomic tones are represented as the following: high frequency (HF) = parasympathetic tone, low frequency (LF) = sympathetic, and very low frequency (VLF) = renin-angiotensin aldosterone system. The relative sympathetic to parasympathetic tone was expressed as LF/HF ratio. Baseline hemodynamic parameters were equal for the S (n = 11) and NS groups. LF/HF was lower at baseline for the NS group but was higher after hemorrhage and the resuscitation period indicative of a predominately parasympathetic response during hemorrhagic shock before mortality. HF signal was lower in the NS group during the resuscitation indicating a relatively lower sympathetic tone during hemorrhagic shock, which may have contributed to mortality. Finally, the NS group had a lower VLF signal at baseline (e.g., [S] 16.3 ± 2.5 versus [NS] 4.6 ± 2.9 P < 0.05,) which was predictive of mortality and hemodynamic instability in response to a similar hemorrhagic injury. An increased LF/HF ratio, indicative of parasympathetic predominance following injury and during resuscitation of hemorrhagic shock was a marker of impending death. Spectral analysis of heart rate variability can also identify autonomic lability following hemorrhagic injuries with implications for first responder triage. Furthermore, a decreased VLF signal at baseline indicates an additional marker of hemodynamic instability and marker of mortality following a hemorrhagic injury. These data indicate that continuous quantitative assessment of autonomic response can be a predictor of mortality and potentially guide resuscitation of patients in hemorrhagic shock. Copyright © 2017 Elsevier Inc. All rights reserved.
Pal, Gopal Krushna; Ganesh, Venkata; Karthik, Shanmugavel; Nanda, Nivedita; Pal, Pravati
2014-01-01
Assessment of short-term practice of relaxation therapy on autonomic and cardiovascular functions in first-year medical students. Case-control, interventional study. Medical college laboratory. Sixty-seven medical students, divided into two groups: study group (n = 35) and control group (n = 32). Study group subjects practiced relaxation therapy (shavasana with a soothing background music) daily 1 hour for 6 weeks. Control group did not practice relaxation techniques. Cardiovascular parameters and spectral indices of heart rate variability (HRV) were recorded before and after the 6-week practice of relaxation therapy. The data between the groups and the data before and after practice of relaxation techniques were analyzed by one-way analysis of variance and Student t-test. In the study group, prediction of low-frequency to high-frequency ratio (LF-HF) of HRV, the marker of sympathovagal balance, to blood pressure (BP) status was assessed by logistic regression. In the study group, there was significant reduction in heart rate (p = .0001), systolic (p = .0010) and diastolic (p = .0021) pressure, and rate pressure product (p < .0001), and improvement in HRV indices, following 6 weeks of relaxation therapy. As determined by regression model, prediction of LF-HF to BP status was more significant (odds ratio, 2.7; p = .009) after practice of relaxation therapy. There was no significant alteration in these parameters in control subjects. Short-term practice of relaxation therapy can improve autonomic balance and promote cardiovascular health of medical students. Sympathovagal balance is directly linked to BP status in these individuals.
Shinba, Toshikazu; Kariya, Nobutoshi; Matsui, Yasue; Ozawa, Nobuyuki; Matsuda, Yoshiki; Yamamoto, Ken-Ichi
2008-10-01
Previous studies have shown that heart rate variability (HRV) measurement is useful in investigating the pathophysiology of various psychiatric disorders. The present study further examined its usefulness in evaluating the mental health of normal subjects with respect to anxiety and depressiveness. Heart rate (HR) and HRV were measured tonometrically at the wrist in 43 normal subjects not only in the resting condition but also during a task (random number generation) to assess the responsiveness. For HRV measurement, high-frequency (HF; 0.15-0.4 Hz) and low-frequency (LF; 0.04-0.15 Hz) components of HRV were obtained using MemCalc, a time series analysis technique that combines a non-linear least square method with maximum entropy method. For psychological evaluation of anxiety and depressiveness, two self-report questionnaires were used: State-Trait Anxiety Inventory (STAI) and Self-Rating Depression Scale (SDS). No significant relation was observed between HR and HRV indices, and the psychological scores both in the resting and task conditions. By task application, HF decreased, and LF/HF and HR increased, and significant correlation with psychological scores was found in the responsiveness to task measured by the ratio of HRV and HR indices during the task to that at rest (task/rest ratio). A positive relationship was found between task/rest ratio for HF, and STAI and SDS scores. Task/rest ratio of HR was negatively correlated with STAI-state score. Decreased HRV response to task application is related to anxiety and depressiveness. Decreased autonomic responsiveness could serve as a sign of psychological dysfunction.
Sun, Guanghao; Shinba, Toshikazu; Kirimoto, Tetsuo; Matsui, Takemi
2016-01-01
Heart rate variability (HRV) has been intensively studied as a promising biological marker of major depressive disorder (MDD). Our previous study confirmed that autonomic activity and reactivity in depression revealed by HRV during rest and mental task (MT) conditions can be used as diagnostic measures and in clinical evaluation. In this study, logistic regression analysis (LRA) was utilized for the classification and prediction of MDD based on HRV data obtained in an MT paradigm. Power spectral analysis of HRV on R-R intervals before, during, and after an MT (random number generation) was performed in 44 drug-naïve patients with MDD and 47 healthy control subjects at Department of Psychiatry in Shizuoka Saiseikai General Hospital. Logit scores of LRA determined by HRV indices and heart rates discriminated patients with MDD from healthy subjects. The high frequency (HF) component of HRV and the ratio of the low frequency (LF) component to the HF component (LF/HF) correspond to parasympathetic and sympathovagal balance, respectively. The LRA achieved a sensitivity and specificity of 80.0 and 79.0%, respectively, at an optimum cutoff logit score (0.28). Misclassifications occurred only when the logit score was close to the cutoff score. Logit scores also correlated significantly with subjective self-rating depression scale scores ( p < 0.05). HRV indices recorded during a MT may be an objective tool for screening patients with MDD in psychiatric practice. The proposed method appears promising for not only objective and rapid MDD screening but also evaluation of its severity.
Haptic interfaces using dielectric electroactive polymers
NASA Astrophysics Data System (ADS)
Ozsecen, Muzaffer Y.; Sivak, Mark; Mavroidis, Constantinos
2010-04-01
Quality, amplitude and frequency of the interaction forces between a human and an actuator are essential traits for haptic applications. A variety of Electro-Active Polymer (EAP) based actuators can provide these characteristics simultaneously with quiet operation, low weight, high power density and fast response. This paper demonstrates a rolled Dielectric Elastomer Actuator (DEA) being used as a telepresence device in a heart beat measurement application. In the this testing, heart signals were acquired from a remote location using a wireless heart rate sensor, sent through a network and DEA was used to haptically reproduce the heart beats at the medical expert's location. A series of preliminary human subject tests were conducted that demonstrated that a) DE based haptic feeling can be used in heart beat measurement tests and b) through subjective testing the stiffness and actuator properties of the EAP can be tuned for a variety of applications.
Heart sound segmentation of pediatric auscultations using wavelet analysis.
Castro, Ana; Vinhoza, Tiago T V; Mattos, Sandra S; Coimbra, Miguel T
2013-01-01
Auscultation is widely applied in clinical activity, nonetheless sound interpretation is dependent on clinician training and experience. Heart sound features such as spatial loudness, relative amplitude, murmurs, and localization of each component may be indicative of pathology. In this study we propose a segmentation algorithm to extract heart sound components (S1 and S2) based on it's time and frequency characteristics. This algorithm takes advantage of the knowledge of the heart cycle times (systolic and diastolic periods) and of the spectral characteristics of each component, through wavelet analysis. Data collected in a clinical environment, and annotated by a clinician was used to assess algorithm's performance. Heart sound components were correctly identified in 99.5% of the annotated events. S1 and S2 detection rates were 90.9% and 93.3% respectively. The median difference between annotated and detected events was of 33.9 ms.
Iliescu, Radu; Tudorancea, Ionut; Irwin, Eric D.
2013-01-01
The sensitivity of baroreflex control of heart rate is depressed in subjects with obesity hypertension, which increases the risk for cardiac arrhythmias. The mechanisms are not fully known, and there are no therapies to improve this dysfunction. To determine the cardiovascular dynamic effects of progressive increases in body weight leading to obesity and hypertension in dogs fed a high-fat diet, 24-h continuous recordings of spontaneous fluctuations in blood pressure and heart rate were analyzed in the time and frequency domains. Furthermore, we investigated whether autonomic mechanisms stimulated by chronic baroreflex activation and renal denervation—current therapies in patients with resistant hypertension, who are commonly obese—restore cardiovascular dynamic control. Increases in body weight to ∼150% of control led to a gradual increase in mean arterial pressure to 17 ± 3 mmHg above control (100 ± 2 mmHg) after 4 wk on the high-fat diet. In contrast to the gradual increase in arterial pressure, tachycardia, attenuated chronotropic baroreflex responses, and reduced heart rate variability were manifest within 1–4 days on high-fat intake, reaching 130 ± 4 beats per minute (bpm) (control = 86 ± 3 bpm) and ∼45% and <20%, respectively, of control levels. Subsequently, both baroreflex activation and renal denervation abolished the hypertension. However, only baroreflex activation effectively attenuated the tachycardia and restored cardiac baroreflex sensitivity and heart rate variability. These findings suggest that baroreflex activation therapy may reduce the risk factors for cardiac arrhythmias as well as lower arterial pressure. PMID:23913707
Fidler, Richard L; Pelter, Michele M; Drew, Barbara J; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J Matt; Hu, Xiao
2017-01-01
Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.
Segovia, Victoria; Manterola, Carlos; González, Marcelo; Rodríguez-Núñez, Iván
Cardiovascular diseases are a significant cause of morbidity and mortality in the general population. In this sense, the autonomic imbalance is the cornerstone of the pathophysiology underlying the development of these diseases. The aim of this study was to determine the efficacy of exercise training on heart rate variability (HRV) in adult patients with chronic heart failure. A systematic literature review was conducted in electronic databases. The considered studies were randomised clinical trials, quasi-experimental studies with non-randomised control group, quasi-experimental studies with analysis of pre- and post- intervention, and crossover studies with randomly assigned training and non-training periods. The standardised mean differences were calculated between pre- and post-intervention in both the control and experimental group. Within-subject analysis of the control group showed no statistical significance in the standardised mean differences of HRV. In the experimental group, the standardised mean differences were positive for the root mean square of successive difference (+0.468±0.215; P=.032), high frequency band (HF) (0.934±0.256; P < .001) and low frequency band (LF) (< 0.415±0.096; P=.001). Moreover, the standardised mean difference was negative for LF/HF (-0.747±0.369, P=<.044). On the other hand, only 3 studies entered the comparative meta-analysis. The effect of exercise training was favourable for the experimental group in LF/HF (-2.21±95% CI: -3.83 to -0.60), HF, and LF. The exercise training was effective in increasing HRV and restoring the autonomic balance in patients with heart failure. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Oka, Tomoko; Matsukura, Makoto; Okamoto, Miwako; Harada, Noriaki; Kitano, Takao; Miike, Teruhisa; Futatsuka, Makoto
2002-12-01
In order to assess the cardiovascular autonomic nervous functions in patients with fetal type Minamata disease (FMD), we investigated blood pressure (BP), and conducted time and frequency domain analysis of heart rate variability (HRV). Subjects were 9 patients in Meisuien recognized as FMD, and 13 healthy age matched control subjects. HRV and BP were assessed after subjects rested in a supine position for 10 minutes. Electrocardiographic (ECG) data were collected for 3 minutes during natural breathing. Time domain analysis (the average of R-R intervals [Mean RR], standard deviation of R-R intervals [SD RR], coefficient of variation [CV]), and frequency domain analysis by fast Fourier transformation (FFT) (power of low frequency [LF] and high frequency [HF] component, expressed in normalized units[nu]) were then conducted. In the time domain analysis, the mean RR of the FMD group was significantly lower than that of the control group. Neither SD RR nor CV showed significant differences between the two groups, but both tended to be lower in the FMD group. In the frequency domain analysis, the HF component of the FMD group was significantly lower than that of the control group. Pulse pressure (PP) was significantly lower in the FMD subjects. These findings suggest that parasympathetic nervous dysfunction might exist in FMD patients, who were exposed to high doses of methylmercury (MeHg) during the prenatal period. Decrease of PP might be due to degenerative changes of blood vessels driven by exposure to high doses of MeHg.
Noujaim, Sami F; Pandit, Sandeep V; Berenfeld, Omer; Vikstrom, Karen; Cerrone, Marina; Mironov, Sergey; Zugermayr, Michelle; Lopatin, Anatoli N; Jalife, José
2007-01-01
Previous studies have suggested an important role for the inward rectifier K+ current (IK1) in stabilizing rotors responsible for ventricular tachycardia (VT) and fibrillation (VF). To test this hypothesis, we used a line of transgenic mice (TG) overexpressing Kir 2.1–green fluorescent protein (GFP) fusion protein in a cardiac-specific manner. Optical mapping of the epicardial surface in ventricles showed that the Langendorff-perfused TG hearts were able to sustain stable VT/VF for 350 ± 1181 s at a very high dominant frequency (DF) of 44.6 ± 4.3 Hz. In contrast, tachyarrhythmias in wild-type hearts (WT) were short-lived (3 ± 9 s), and the DF was 26.3 ± 5.2 Hz. The stable, high frequency, reentrant activity in TG hearts slowed down, and eventually terminated in the presence of 10 μm Ba2+, suggesting an important role for IK1. Moreover, by increasing IK1 density in a two-dimensional computer model having realistic mouse ionic and action potential properties, a highly stable, fast rotor (≈45 Hz) could be induced. Simulations suggested that the TG hearts allowed such a fast and stable rotor because of both greater outward conductance at the core and shortened action potential duration in the core vicinity, as well as increased excitability, in part due to faster recovery of Na+ current. The latter resulted in a larger rate of increase in the local conduction velocity as a function of the distance from the core in TG compared to WT hearts, in both simulations and experiments. Finally, simulations showed that rotor frequencies were more sensitive to changes (doubling) in IK1, compared to other K+ currents. In combination, these results provide the first direct evidence that IK1 up-regulation in the mouse heart is a substrate for stable and very fast rotors. PMID:17095564
Orita, Makiko; Hayashida, Naomi; Shinkawa, Tetsuko; Kudo, Takashi; Koga, Mikitoshi; Togo, Michita; Katayama, Sotetsu; Hiramatsu, Kozaburo; Mori, Shunsuke; Takamura, Noboru
2012-07-01
Severely and multiply disabled children (SMDC) are frequently affected in more than one area of development, resulting in multiple disabilities. The aim of the study was to evaluate the efficacy of music therapy in SMDC using monitoring changes in the autonomic nervous system, by the frequency domain analysis of heart rate variability. We studied six patients with SMDC (3 patients with cerebral palsy, 1 patient with posttraumatic syndrome after head injury, 1 patient with herpes encephalitis sequelae, and 1 patient with Lennox-Gastaut syndrome characterized by frequent seizures, developmental delay and psychological and behavioral problems), aged 18-26 (mean 22.5 ± 3.5). By frequency domain method using electrocardiography, we measured the high frequency (HF; with a frequency ranging from 0.15 to 0.4 Hz), which represents parasympathetic activity, the low frequency/high frequency ratio, which represents sympathetic activity between the sympathetic and parasympathetic activities, and heart rate. A music therapist performed therapy to all patients through the piano playing for 50 min. We monitored each study participant for 150 min before therapy, 50 min during therapy, and 10 min after therapy. Interestingly, four of 6 patients showed significantly lower HF components during music therapy than before therapy, suggesting that these four patients might react to music therapy through the suppression of parasympathetic nervous activities. Thus, music therapy can suppress parasympathetic nervous activities in some patients with SMDC. The monitoring changes in the autonomic nervous activities could be a powerful tool for the objective evaluation of music therapy in patients with SMDC.
Nishiyama, Tomoki
2016-01-01
The purpose of this study was to compare cardiac sympathetic and parasympathetic balance using heart rate variability (HRV) during induction of anaesthesia between sevoflurane and isoflurane in combination with nitrous oxide. 40 individuals aged from 30 to 60 years, scheduled for general anaesthesia were equally divided into sevoflurane or isoflurane groups. After 100% oxygen inhalation for a few minutes, anaesthesia was induced with nitrous oxide 3 L min-1, oxygen 3 L min-1 and sevoflurane or isoflurane. Sevoflurane or isoflurane concentration was increased by 0.5% every 2 to 3 breaths until 5% was attained for sevoflurane, or 3% for isoflurane. Vecuronium was administered to facilitate tracheal intubation. After intubation, sevoflurane was set to 2% while isoflurane was set to 1% with nitrous oxide with oxygen (1:1) for 5 min. Both sevoflurane and isoflurane provoked a decrease in blood pressure, total power, the low frequency component (LF), and high frequency component (HF) of HRV. Although the heart rate increased during isoflurane anaesthesia, it decreased under sevoflurane. The power of LF and HF also decreased in both groups. LF was higher in the isoflurane group while HF was higher in the sevoflurane group. The LF/HF ratio increased transiently in the isoflurane group, but decreased in the sevoflurane group. Anaesthesia induction with isoflurane-nitrous oxide transiently increased cardiac sympathetic activity, while sevoflurane-nitrous oxide decreased both cardiac sympathetic and parasympathetic activities. The balance of cardiac parasympathetic/sympathetic activity was higher in sevoflurane anaesthesia.
Reduced heart rate variability during sleep in long-duration spaceflight.
Xu, D; Shoemaker, J K; Blaber, A P; Arbeille, P; Fraser, K; Hughson, R L
2013-07-15
Limited data are available to describe the regulation of heart rate (HR) during sleep in spaceflight. Sleep provides a stable supine baseline during preflight Earth recordings for comparison of heart rate variability (HRV) over a wide range of frequencies using both linear, complexity, and fractal indicators. The current study investigated the effect of long-duration spaceflight on HR and HRV during sleep in seven astronauts aboard the International Space Station up to 6 mo. Measurements included electrocardiographic waveforms from Holter monitors and simultaneous movement records from accelerometers before, during, and after the flights. HR was unchanged inflight and elevated postflight [59.6 ± 8.9 beats per minute (bpm) compared with preflight 53.3 ± 7.3 bpm; P < 0.01]. Compared with preflight data, HRV indicators from both time domain and power spectral analysis methods were diminished inflight from ultralow to high frequencies and partially recovered to preflight levels after landing. During inflight and at postflight, complexity and fractal properties of HR were not different from preflight properties. Slow fluctuations (<0.04 Hz) in HR presented moderate correlations with movements during sleep, partially accounting for the reduction in HRV. In summary, substantial reduction in HRV was observed with linear, but not with complexity and fractal, methods of analysis. These results suggest that periodic elements that influence regulation of HR through reflex mechanisms are altered during sleep in spaceflight but that underlying system complexity and fractal dynamics were not altered.
Wang, Yu-Jen; Wang, Yi-Zen; Yeh, Mei-Ling
2016-07-01
Numerous studies have demonstrated autonomic abnormalities in various pain conditions. However, few have investigated heart rate variability (HRV) in young women with primary dysmenorrhea, and the conclusions have been inconsistent. More evidence is required to confirm the reported trend for consistent fluctuation of HRV parameters in dysmenorrhea. The study's aim was to determine whether significant differences exist between young women with and without dysmenorrhea for heart rate (HR), blood pressure (BP), and HRV parameters during menses. A prospective comparison design with repeated measures was used. Sixty-six women aged 18-25 with dysmenorrhea and 54 eumenorrheic women were recruited from a university in northern Taiwan. High-frequency and low-frequency HRV parameters (HF and LF), LF/HF ratio, BP, and HR were measured daily between 8 p.m. and 10 p.m. from Day 1 to Day 6 during menses. The generalized estimating equation was used to analyze the effects of group, time, and Group × Time interaction on these variables. HF values were significantly lower in the dysmenorrhea than in the eumenorrhea group, but there were no differences in BP, HR, LF, or LF/HF ratio. Reduced HF values reflect reduced parasympathetic activity and autonomic instability in young women with dysmenorrhea. Future longitudinal studies are warranted to examine autonomic regulation in menstrual pain of varying intensities associated with dysmenorrhea-related symptoms and to clarify the causal relationship between dysmenorrhea and HRV fluctuations. © The Author(s) 2016.
Increased heart rate variability during nondirective meditation.
Nesvold, Anders; Fagerland, Morten W; Davanger, Svend; Ellingsen, Øyvind; Solberg, Erik E; Holen, Are; Sevre, Knut; Atar, Dan
2012-08-01
Meditation practices are in use for relaxation and stress reduction. Some studies indicate beneficial cardiovascular health effects of meditation. The effects on the autonomous nervous system seem to vary among techniques. The purpose of the present study was to identify autonomic nerve activity changes during nondirective meditation. Heart rate variability (HRV), blood pressure variability (BPV), and baroreflex sensitivity (BRS) were monitored in 27 middle-aged healthy participants of both genders, first during 20 min regular rest with eyes closed, thereafter practising Acem meditation for 20 min. Haemodynamic and autonomic data were collected continuously (beat-to-beat) and non-invasively. HRV and BPV parameters were estimated by power spectral analyses, computed by an autoregressive model. Spontaneous activity of baroreceptors were determined by the sequence method. Primary outcomes were changes in HRV, BPV, and BRS between rest and meditation. HRV increased in the low-frequency (LF) and high-frequency (HF) bands during meditation, compared with rest (p = 0.014, 0.013, respectively). Power spectral density of the RR-intervals increased as well (p = 0.012). LF/HF ratio decreased non-significantly, and a reduction of LF-BPV power was observed during meditation (p < 0.001). There was no significant difference in BRS. Respiration and heart rates remained unchanged. Blood pressure increased slightly during meditation. There is an increased parasympathetic and reduced sympathetic nerve activity and increased overall HRV, while practising the technique. Hence, nondirective meditation by the middle aged may contribute towards a reduction of cardiovascular risk.
Sabino, João Paulo J; da Silva, Carlos Alberto Aguiar; de Melo, Rubens Fernando; Fazan, Rubens; Salgado, Helio C
2013-01-01
Sympathetic hyperactivity and its outcome in heart failure have been thoroughly investigated to determine the focus of pharmacologic approaches targeting the sympathetic nervous system in the treatment of this pathophysiological condition. On the other hand, therapeutic approaches aiming to protect the reduced cardiac parasympathetic function have not received much attention. The present study evaluated rats with chronic heart failure (six to seven weeks after coronary artery ligation) and the effects of an increased parasympathetic function by pyridostigmine (an acetylcholinesterase inhibitor) on the following aspects: arterial pressure (AP), heart rate (HR), baroreceptor and Bezold-Jarisch reflex, pulse interval (PI) and AP variability, cardiac sympathetic and parasympathetic tonus, intrinsic heart rate (i-HR) and cardiac function. Conscious rats with heart failure exhibited no change in HR, Bezold-Jarisch reflex, PI variability and cardiac sympathetic tonus. On the other hand, these animals presented hypotension and reduced baroreflex sensitivity, power in the low frequency (LF) band of the systolic AP spectrum, cardiac parasympathetic tonus and i-HR, while anesthetized rats exhibited reduced cardiac performance. Pyridostigmine prevented the attenuation of all the parameters examined, except basal AP and cardiac performance. In conclusion, the blockade of acetylcholinesterase with pyridostigmine was revealed to be an important pharmacological approach, which could be used to increase parasympathetic function and to improve a number of cardiocirculatory parameters in rats with heart failure. Copyright © 2012 Elsevier B.V. All rights reserved.
Chu, I-Hua; Wu, Wen-Lan; Lin, I-Mei; Chang, Yu-Kai; Lin, Yuh-Jen; Yang, Pin-Chen
2017-04-01
The purpose of the study was to investigate the effects of a 12-week yoga program on heart rate variability (HRV) and depressive symptoms in depressed women. This was a randomized controlled trial. Twenty-six sedentary women scoring ≥14 on the Beck Depression Inventory-II were randomized to either the yoga or the control group. The yoga group completed a 12-week yoga program, which took place twice a week for 60 min per session and consisted of breathing exercises, yoga pose practice, and supine meditation/relaxation. The control group was instructed not to engage in any yoga practice and to maintain their usual level of physical activity during the course of the study. Participants' HRV, depressive symptoms, and perceived stress were assessed at baseline and post-test. The yoga group had a significant increase in high-frequency HRV and decreases in low-frequency HRV and low frequency/high frequency ratio after the intervention. The yoga group also reported significantly reduced depressive symptoms and perceived stress. No change was found in the control group. A 12-week yoga program was effective in increasing parasympathetic tone and reducing depressive symptoms and perceived stress in women with elevated depressive symptoms. Regular yoga practice may be recommended for women to cope with their depressive symptoms and stress and to improve their HRV.
Heart Rate Fragmentation: A Symbolic Dynamical Approach.
Costa, Madalena D; Davis, Roger B; Goldberger, Ary L
2017-01-01
Background: We recently introduced the concept of heart rate fragmentation along with a set of metrics for its quantification. The term was coined to refer to an increase in the percentage of changes in heart rate acceleration sign, a dynamical marker of a type of anomalous variability. The effort was motivated by the observation that fragmentation, which is consistent with the breakdown of the neuroautonomic-electrophysiologic control system of the sino-atrial node, could confound traditional short-term analysis of heart rate variability. Objective: The objectives of this study were to: (1) introduce a symbolic dynamical approach to the problem of quantifying heart rate fragmentation; (2) evaluate how the distribution of the different dynamical patterns ("words") varied with the participants' age in a group of healthy subjects and patients with coronary artery disease (CAD); and (3) quantify the differences in the fragmentation patterns between the two sample populations. Methods: The symbolic dynamical method employed here was based on a ternary map of the increment NN interval time series and on the analysis of the relative frequency of symbolic sequences (words) with a pre-defined set of features. We analyzed annotated, open-access Holter databases of healthy subjects and patients with CAD, provided by the University of Rochester Telemetric and Holter ECG Warehouse (THEW). Results: The degree of fragmentation was significantly higher in older individuals than in their younger counterparts. However, the fragmentation patterns were different in the two sample populations. In healthy subjects, older age was significantly associated with a higher percentage of transitions from acceleration/deceleration to zero acceleration and vice versa (termed "soft" inflection points). In patients with CAD, older age was also significantly associated with higher percentages of frank reversals in heart rate acceleration (transitions from acceleration to deceleration and vice versa , termed "hard" inflection points). Compared to healthy subjects, patients with CAD had significantly higher percentages of soft and hard inflection points, an increased percentage of words with a high degree of fragmentation and a decreased percentage of words with a lower degree of fragmentation. Conclusion: The symbolic dynamical method employed here was useful to probe the newly recognized property of heart rate fragmentation. The findings from these cross-sectional studies confirm that CAD and older age are associated with higher levels of heart rate fragmentation. Furthermore, fragmentation with healthy aging appears to be phenotypically different from fragmentation in the context of CAD.
Markil, Nina; Whitehurst, Michael; Jacobs, Patrick L; Zoeller, Robert F
2012-10-01
The measurement of heart rate variability (HRV) is often applied as an index of autonomic nervous system (ANS) balance and, therefore, myocardial stability. Previous studies have suggested that relaxation or mind-body exercise can influence ANS balance positively as measured by HRV but may act via different mechanisms. No studies, to the authors' knowledge, have examined the acute response in HRV to interventions combining relaxation and mind-body exercise. The objective of this study was to compare the acute HRV responses to Yoga Nidra relaxation alone versus Yoga Nidra relaxation preceded by Hatha yoga. This was a randomized counter-balanced trial. The trial was conducted in a university exercise physiology laboratory. Subjects included 20 women and men (29.15±6.98 years of age, with a range of 18-47 years). Participants completed a yoga plus relaxation (YR) session and a relaxation only (R) session. The YR condition produced significant changes from baseline in heart rate (HR; beats per minute [bpm], p<0.001) and indices of HRV: R-R (ms, p<0.001), pNN50 (%, p=0.009), low frequency (LF; %, p=0.008) and high frequency (HF; %, p=0.035). The R condition produced significant changes from baseline in heart rate (bpm, p<0.001) as well as indices of HRV: R-R (ms, p<0.001), HF (ms(2), p=0.004), LF (%, p=0.005), HF (%, p=0.008) and LF:HF ratio (%, p=0.008). There were no significant differences between conditions at baseline nor for the changes from baseline for any of the variables. These changes demonstrate a favorable shift in autonomic balance to the parasympathetic branch of the ANS for both conditions, and that Yoga Nidra relaxation produces favorable changes in measures of HRV whether alone or preceded by a bout of Hatha yoga.
Tobón, Diana P.; Jayaraman, Srinivasan
2017-01-01
The last few years has seen a proliferation of wearable electrocardiogram (ECG) devices in the market with applications in fitness tracking, patient monitoring, athletic performance assessment, stress and fatigue detection, and biometrics, to name a few. The majority of these applications rely on the computation of the heart rate (HR) and the so-called heart rate variability (HRV) index via time-, frequency-, or non-linear-domain approaches. Wearable/portable devices, however, are highly susceptible to artifacts, particularly those resultant from movement. These artifacts can hamper HR/HRV measurement, thus pose a serious threat to cardiac monitoring applications. While current solutions rely on ECG enhancement as a pre-processing step prior to HR/HRV calculation, existing artifact removal algorithms still perform poorly under extremely noisy scenarios. To overcome this limitation, we take an alternate approach and propose the use of a spectro-temporal ECG signal representation that we show separates cardiac components from artifacts. More specifically, by quantifying the rate-of-change of ECG spectral components over time, we show that heart rate estimates can be reliably obtained even in extremely noisy signals, thus bypassing the need for ECG enhancement. With such HR measurements in hands, we then propose a new noise-robust HRV index termed MD-HRV (modulation-domain HRV) computed as the standard deviation of the obtained HR values. Experiments with synthetic ECG signals corrupted at various different signal-to-noise levels, as well as recorded noisy signals show the proposed measure outperforming several HRV benchmark parameters computed post wavelet-based enhancement. These findings suggest that the proposed HR measures and derived MD-HRV metric are well-suited for ambulant cardiac monitoring applications, particularly those involving intense movement (e.g., elite athletic training). PMID:29255653
Automatic zebrafish heartbeat detection and analysis for zebrafish embryos.
Pylatiuk, Christian; Sanchez, Daniela; Mikut, Ralf; Alshut, Rüdiger; Reischl, Markus; Hirth, Sofia; Rottbauer, Wolfgang; Just, Steffen
2014-08-01
A fully automatic detection and analysis method of heartbeats in videos of nonfixed and nonanesthetized zebrafish embryos is presented. This method reduces the manual workload and time needed for preparation and imaging of the zebrafish embryos, as well as for evaluating heartbeat parameters such as frequency, beat-to-beat intervals, and arrhythmicity. The method is validated by a comparison of the results from automatic and manual detection of the heart rates of wild-type zebrafish embryos 36-120 h postfertilization and of embryonic hearts with bradycardia and pauses in the cardiac contraction.
Spectral analysis of heart rate dynamics in elderly persons with postprandial hypotension
NASA Technical Reports Server (NTRS)
Ryan, S. M.; Goldberger, A. L.; Ruthazer, R.; Mietus, J.; Lipsitz, L. A.
1992-01-01
Prior studies suggest that postprandial hypotension in elderly persons may be due to defective sympathetic nervous system activation. We examined autonomic control of heart rate (HR) after a meal using spectral analysis of HR data in 13 old (89 +/- 6 years) and 7 young (24 +/- 4 years) subjects. Total spectral power, an index of overall HR variability, was calculated for the frequency band between 0.01 and 0.40 Hz. Relatively low-frequency power, associated with sympathetic nervous system and baroreflex activation, was calculated for the 0.01 to 0.15 Hz band. High-frequency power, representing parasympathetic influences on HR, was calculated for the 0.15 to 0.40 Hz band. Mean arterial blood pressure declined 27 +/- 8 mm Hg by 60 minutes after the meal in elderly subjects, compared with 9 +/- 8 mm Hg in young subjects (p less than or equal to 0.0001, young vs old). The mean change in low-frequency HR power from 30 to 50 minutes after the meal was +19.4 +/- 25.3 U in young subjects versus -0.1 +/- 1.5 U in old subjects (p less than or equal to 0.02). Mean change in total power was also greater in young (19.0 +/- 26.6 U) subjects compared with old subjects (0.0 +/- 1.6 U, p greater than or equal to 0.02). Mean ratio of low:high-frequency power increased 3.1 +/- 3.3 U in young subjects vs 0.5 +/- 2.7 U in old subjects (p less than or equal to 0.01). The increase in low-frequency HR power and in the low:high frequency band ratio in young subjects is consistent with sympathetic activation in the postprandial period.(ABSTRACT TRUNCATED AT 250 WORDS).
Ziółkowski, Wiesław; Badtke, Piotr; Zajączkowski, Miłosz A.; Flis, Damian J.; Figarski, Adam; Smolińska-Bylańska, Maria; Wierzba, Tomasz H.
2018-01-01
Background It has long been suggested that reactive oxygen species (ROS) play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO), which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear. Aim The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV) analysis. Material and methods 16 conscious male Wistar rats (350 g): control-untreated (N = 8) and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg), administered intraperitoneally (N = 8), were exposed to controlled hypobaric hypoxia (1h) in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression). Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV) analysis in order to calculate the following time-domain parameters: mean RR interval (RRi), SDNN (standard deviation of all normal NN intervals), rMSSD (square root of the mean of the squares of differences between adjacent NN intervals), frequency-domain parameters (FFT method): TSP (total spectral power) as well as low and high frequency band powers (LF and HF). At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPx) were measures in erythrocyte lysates. Results Allopurinol reduced oxidative stress which was the result of hypoxia/hyperoxia, as shown by decreased 8-isoprostane plasma concentration. XO inhibition did not markedly influence HRV parameters in standard normoxia. However, during hypoxia, as well as hyperoxia, allopurinol administration resulted in a significant increase of autonomic control upon the heart as shown by increased SDNN and TSP, with an increased vagal contribution (increased rMSSD and HF), whereas sympathovagal indexes (LF/HF, SDNN/rMSSD) remained unchanged. Conclusions Observed regulatory effects of XO inhibition did not confirm preliminary hypothesis which suggested that an antioxidant such as allopurinol might activate chemoreflex resulting in augmented sympathetic discharge to the heart. The HRV regulatory profile of XO inhibition observed during hypoxia as well as post-hypoxic hyperoxia corresponds to reported reduced risk of sudden cardiovascular events. Therefore our data provide a new argument for therapeutical use of allopurinol in hypoxic conditions. PMID:29432445
Zajączkowski, Stanisław; Ziółkowski, Wiesław; Badtke, Piotr; Zajączkowski, Miłosz A; Flis, Damian J; Figarski, Adam; Smolińska-Bylańska, Maria; Wierzba, Tomasz H
2018-01-01
It has long been suggested that reactive oxygen species (ROS) play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO), which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear. The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV) analysis. 16 conscious male Wistar rats (350 g): control-untreated (N = 8) and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg), administered intraperitoneally (N = 8), were exposed to controlled hypobaric hypoxia (1h) in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression). Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV) analysis in order to calculate the following time-domain parameters: mean RR interval (RRi), SDNN (standard deviation of all normal NN intervals), rMSSD (square root of the mean of the squares of differences between adjacent NN intervals), frequency-domain parameters (FFT method): TSP (total spectral power) as well as low and high frequency band powers (LF and HF). At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPx) were measures in erythrocyte lysates. Allopurinol reduced oxidative stress which was the result of hypoxia/hyperoxia, as shown by decreased 8-isoprostane plasma concentration. XO inhibition did not markedly influence HRV parameters in standard normoxia. However, during hypoxia, as well as hyperoxia, allopurinol administration resulted in a significant increase of autonomic control upon the heart as shown by increased SDNN and TSP, with an increased vagal contribution (increased rMSSD and HF), whereas sympathovagal indexes (LF/HF, SDNN/rMSSD) remained unchanged. Observed regulatory effects of XO inhibition did not confirm preliminary hypothesis which suggested that an antioxidant such as allopurinol might activate chemoreflex resulting in augmented sympathetic discharge to the heart. The HRV regulatory profile of XO inhibition observed during hypoxia as well as post-hypoxic hyperoxia corresponds to reported reduced risk of sudden cardiovascular events. Therefore our data provide a new argument for therapeutical use of allopurinol in hypoxic conditions.
Holland, Alexander; Aboy, Mateo
2009-07-01
We present a novel method to iteratively calculate discrete Fourier transforms for discrete time signals with sample time intervals that may be widely nonuniform. The proposed recursive Fourier transform (RFT) does not require interpolation of the samples to uniform time intervals, and each iterative transform update of N frequencies has computational order N. Because of the inherent non-uniformity in the time between successive heart beats, an application particularly well suited for this transform is power spectral density (PSD) estimation for heart rate variability. We compare RFT based spectrum estimation with Lomb-Scargle Transform (LST) based estimation. PSD estimation based on the LST also does not require uniform time samples, but the LST has a computational order greater than Nlog(N). We conducted an assessment study involving the analysis of quasi-stationary signals with various levels of randomly missing heart beats. Our results indicate that the RFT leads to comparable estimation performance to the LST with significantly less computational overhead and complexity for applications requiring iterative spectrum estimations.
Psychophysiological Assessment of Fatigue in Commercial Aviation Operations
NASA Technical Reports Server (NTRS)
Hernandez, Norma; Cowings, Patricia; Toscano, William
2012-01-01
The overall goal of this study is to improve our understanding of crew work hours, workload, sleep, fatigue, and performance, and the relationships between these variables on actual flight deck performance. Specifically, this study will provide objective measures of physiology and performance, which may benefit investigators in identifying fatigue levels of operators in commercial aviation and provide a way to better design strategies to limit crew fatigue. This research was supported by an agreement between NASA Ames Research Center and easyJet Airline Company, Ltd., Luton, UK. Twenty commercial pilots volunteered to participant in the study that included 15 flight duty days. Participants wore a Zephyr Bioharness ambulatory physiological monitor each flight day, which measured their heart rate, respiration rate, skin temperature, activity and posture. In addition, pilots completed sleep log diaries, self-report scales of mood, sleepiness and workload, and a Performance Vigilance Task (PVT). All data were sent to NASA researchers for processing and analyses. Heart rate variability data of several subjects were subjected to a spectral analysis to examine power in specific frequency bands. Increased power in low frequency band was associated with reports of higher subjective sleepinesss in some subjects. Analyses of other participants data are currently underway.
Non-Invasive Detection of Respiration and Heart Rate with a Vehicle Seat Sensor.
Wusk, Grace; Gabler, Hampton
2018-05-08
This study demonstrates the feasibility of using a seat sensor designed for occupant classification from a production passenger vehicle to measure an occupant’s respiration rate (RR) and heart rate (HR) in a laboratory setting. Relaying occupant vital signs after a crash could improve emergency response by adding a direct measure of the occupant state to an Advanced Automatic Collision Notification (AACN) system. Data was collected from eleven participants with body weights ranging from 42 to 91 kg using a Ford Mustang passenger seat and seat sensor. Using a ballistocardiography (BCG) approach, the data was processed by time domain filtering and frequency domain analysis using the fast Fourier transform to yield RR and HR in a 1-min sliding window. Resting rates over the 30-min data collection and continuous RR and HR signals were compared to laboratory physiological instruments using the Bland-Altman approach. Differences between the seat sensor and reference sensor were within 5 breaths per minute for resting RR and within 15 beats per minute for resting HR. The time series comparisons for RR and HR were promising with the frequency analysis technique outperforming the peak detection technique. However, future work is necessary for more accurate and reliable real-time monitoring of RR and HR outside the laboratory setting.
Chen, Weihan; Hillyer, Julián F.
2013-01-01
FlyNap (triethylamine) is commonly used to anesthetize Drosophila melanogaster fruit flies. The purpose of this study was to determine whether triethylamine is a suitable anesthetic agent for research into circulatory physiology and immune competence in the mosquito, Anopheles gambiae (Diptera: Culicidae). Recovery experiments showed that mosquitoes awaken from traditional cold anesthesia in less than 7 minutes, but that recovery from FlyNap anesthesia does not begin for several hours. Relative to cold anesthesia, moderate exposures to FlyNap induce an increase in the heart rate, a decrease in the percentage of the time the heart contracts in the anterograde direction, and a decrease in the frequency of heartbeat directional reversals. Experiments employing various combinations of cold and FlyNap anesthesia then showed that cold exposure does not affect basal heart physiology, and that the differences seen between the cold and the FlyNap groups are due to a FlyNap-induced alteration of heart physiology. Furthermore, exposure to FlyNap eliminated the cardioacceleratory effect of crustacean cardioactive peptide (CCAP), and reduced a mosquito’s ability to survive a bacterial infection. Together, these data show that FlyNap is not a suitable substitute to cold anesthesia in experiments assessing mosquito heart function or immune competence. Moreover, these data also illustrate the intricate biology of the insect heart. Specifically, they confirm that the neurohormone CCAP modulates heart rhythms and that it serves as an anterograde pacemaker. PMID:23875027
Papousek, Ilona; Roessler, Andreas; Hinghofer-Szalkay, Helmut; Lang, Uwe; Kolovetsiou-Kreiner, Vassiliki
2013-01-01
Background The autonomic nervous system plays a central role in the functioning of systems critical for the homeostasis maintenance. However, its role in the cardiovascular adaptation to pregnancy-related demands is poorly understood. We explored the maternal cardiovascular systems throughout pregnancy to quantify pregnancy-related autonomic nervous system adaptations. Methodology Continuous monitoring of heart rate (R-R interval; derived from the 3-lead electrocardiography), blood pressure, and thoracic impedance was carried out in thirty-six women at six time-points throughout pregnancy. In order to quantify in addition to the longitudinal effects on baseline levels throughout gestation the immediate adaptive heart rate and blood pressure changes at each time point, a simple reflex test, deep breathing, was applied. Consequently, heart rate variability and blood pressure variability in the low (LF) and high (HF) frequency range, respiration and baroreceptor sensitivity were analyzed in resting conditions and after deep breathing. The adjustment of the rhythms of the R-R interval, blood pressure and respiration partitioned for the sympathetic and the parasympathetic branch of the autonomic nervous system were quantified by the phase synchronization index γ, which has been adopted from the analysis of weakly coupled chaotic oscillators. Results Heart rate and LF/HF ratio increased throughout pregnancy and these effects were accompanied by a continuous loss of baroreceptor sensitivity. The increases in heart rate and LF/HF ratio levels were associated with an increasing decline in the ability to flexibly respond to additional demands (i.e., diminished adaptive responses to deep breathing). The phase synchronization index γ showed that the observed effects could be explained by a decreased coupling of respiration and the cardiovascular system (HF components of heart rate and blood pressure). Conclusions/Significance The findings suggest that during the course of pregnancy the individual systems become increasingly independent to meet the increasing demands placed on the maternal cardiovascular and respiratory system. PMID:23577144
Heart rate variability in stroke patients submitted to an acute bout of aerobic exercise.
Raimundo, Rodrigo Daminello; de Abreu, Luiz Carlos; Adami, Fernando; Vanderlei, Franciele Marques; de Carvalho, Tatiana Dias; Moreno, Isadora Lessa; Pereira, Valdelias Xavier; Valenti, Vitor Engracia; Sato, Monica Akemi
2013-10-01
Stroke has been associated with cardiac autonomic impairment due to damage in central nervous system. Dysfunction in heart rate variability (HRV) may reflect dysfunction of the autonomic nervous system. Aerobic training has been used in the rehabilitation procedure of patients, due to improvement of aerobic function and other beneficial effects as increased recruitment of motor units, favoring the development of muscle fibers. The purpose of this study was to evaluate the cardiac autonomic modulation in patients with stroke before, during, and after an acute bout of aerobic exercise. The heart rate of 38 stroke patients was recorded using a heart rate (HR) monitor and the data were used to assess cardiac autonomic modulation through HRV analysis. The patients were in supine position and remained at resting condition (R) for 10 min before starting the experiment. Afterwards, they were submitted to walking exercise (E) on a treadmill until achieve 50-70% of maximum heart rate. After 30 min of aerobic exercise, the subjects were advised to remain in supine position for additional 30 min in order to record the HR during the recovery (RC) period. The recordings were divided in three periods: RC1, immediately after the end of exercise bout, RC2, between 12 and 17 min of recovery, and RC3, at the final 5 min of recovery. A significant decrease was observed during exercise in the MeanRR index (577.3±92 vs. 861.1+109), RRtri (5.1±2 vs. 9.1±3), high frequency component (11.2±4 vs. 167±135 ms) and SD1 (5.7±2 vs. 16.9±7 ms) compared to resting values. The SDNN index reduced during E (27.6±19) and RC1 (29.9±11), RC2 (27.9±9) and RC3 (32.4±13) compared to resting values (42.4±19). The low frequency component increased during E (545±82), but decreased during RC1 (166.3±129), RC2 (206.9±152), and RC3 (249.5±236) compared to R levels (394.6±315). These findings suggest that stroke patients showed a reduced HRV during and at least 30 min after exercise, due to an autonomic imbalance reflected by increased indexes that represent the sympathetic nervous system.
Cottin, F; Barrey, E; Lopes, P; Billat, V
2006-08-01
Interval training is a commonly used training method for trotting horses. In addition, trainers are provided with efficient and inexpensive heart rate monitor devices for the management of training. Since the high frequency (HF) frequency peak (fHF) of heart rate variability (HRV) corresponds to the breathing frequency in combination with stride frequency during trotting, it is hypothesised that modifications of breathing and stride frequencies induced by repeated exercise could be detected from fHF. RR interval time series of 7 trotting horses were recorded during an interval training session. Interval training was made up of 5 successive 800 m high-velocity trotting runs (H1, H2...H5) separated by 1 min recovery bouts at low speed (R1, R2...R5). Fast Fourier transform (FFT) and Poincaré plot analysis techniques were applied to RR series. Repeated exercise had significant effects on HRV components during interval training. Despite constant trotting velocities during high-speed and recovery, repetition induced a decrease in mean RR interval (H1: 295 +/- 19 vs. H5: 283 +/- 15 msec, P<0.05) and in the root mean square of successive differences in RR series (RMSSD; H1: 6.31 +/- 1.28 vs. H5: 5.31 +/- 1.31 msec, P<0.05). Furthermore, high-speed and recovery repetitions induced an increase in fHF (H1: 1.37 +/- 0.35 vs. H5: 1.62 +/- 0.40 Hz and R1: 0.22 +/- 0.02 vs. R4: 0.64 +/- 0.38 Hz, P<0.05). Hence, recovery induced a decrease in the s.d. of the successive RR series (SDRR; R3: 10.5 +/- 3.96 vs. R5: 6.17 +/- 2.65 msecs, P>0.05) and in the long term index of Poincaré plot (SD2; R1: 43.29 +/- 28.90 vs. R5: 18.19 +/- 9.35 msecs, P<0.05). The observed increase in fHF during the interval training could be induced by alterations of the coupling between breathing and stride frequency linked to the emergence of fatigue. The decrease in SD2 and SDRR during successive recovery bouts could be linked with a deterioration of the recovery pattern. HRV can provide breathing frequency data of Standardbreds during training without any respiratory device. Furthermore, HRV could provide useful makers of the emergence of fatigue states during training.
Practical Approaches to Prescribing Physical Activity and Monitoring Exercise Intensity.
Reed, Jennifer L; Pipe, Andrew L
2016-04-01
Regular physical activity helps to prevent heart disease, and reduces the risk of first or subsequent cardiovascular events. It is recommended that Canadian adults accumulate at least 150 minutes of moderate- to vigorous-intensity aerobic exercise per week, in bouts of 10 minutes or more, and perform muscle- and bone-strengthening activities at least 2 days per week. Individual exercise prescriptions can be developed using the frequency, intensity, time, and type principles. Increasing evidence suggests that high-intensity interval training is efficacious for a broad spectrum of heart health outcomes. Several practical approaches to prescribing and monitoring exercise intensity exist including: heart rate monitoring, the Borg rating of perceived exertion scale, the Talk Test, and, motion sensors. The Borg rating of perceived exertion scale matches a numerical value to an individual's perception of effort, and can also be used to estimate heart rate. The Talk Test, the level at which simple conversation is possible, can be used to monitor desired levels of moderate- to vigorous-intensity exercise. Motion sensors can provide users with practical and useful exercise training information to aid in meeting current exercise recommendations. These approaches can be used by the public, exercise scientists, and clinicians to easily and effectively guide physical activity in a variety of settings. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Huang, Suli; Deng, Qifei; Feng, Jing; Zhang, Xiaomin; Dai, Xiayun; Li, Lu; Yang, Binyao; Wu, Tangchun; Cheng, Jinquan
2016-01-01
We aimed to evaluate the association between polycyclic aromatic hydrocarbons (PAHs)-related microRNAs (miRNAs) and heart rate variability indices in coke oven workers. We recruited 365 male coke oven workers and measured urinary PAH metabolites by gas chromatography-mass spectrometry. Five heart rate variability indices were measured using three-channel Holter monitor. Six miRNAs were detected by TaqMan miRNA assays (Life Technologies, Foster City, CA). miR-24-3p, miR-27a-3p, miR-142-5p, and miR-320b were negatively associated with the root mean of square of successive differences between adjacent normal NN intervals (RMSSD) (P(trend) = 0.006, 0.047, 0.019, 0.011, respectively). miR-142-5p and miR-320b were also negatively associated with standard deviation of all normal to normal NN intervals (SDNN) (P(trend) = 0.01 and 0.035). miR-24-3p, miR-27a-3p, and miR-320b were significantly interacted with multiple PAH metabolites and influenced heart rate variability indices, whereas miR-24-3p also significantly interacted with smoking to influence low frequency (P(interaction) < 0.05 for all). Plasma miRNAs might act as potential biomarkers for the adverse effect of PAH exposure on the cardiovascular system.
Hiraba, Hisao; Inoue, Motoharu; Gora, Kanako; Sato, Takako; Nishimura, Satoshi; Yamaoka, Masaru; Kumakura, Ayano; Ono, Shinya; Wakasa, Hirotugu; Nakayama, Enri; Abe, Kimiko; Ueda, Koichiro
2014-01-01
We previously found that the greatest salivation response in healthy human subjects is produced by facial vibrotactile stimulation of 89 Hz frequency with 1.9 μm amplitude (89 Hz-S), as reported by Hiraba et al. (2012, 20011, and 2008). We assessed relationships between the blood flow to brain via functional near-infrared spectroscopy (fNIRS) in the frontal cortex and autonomic parameters. We used the heart rate (HRV: heart rate variability analysis in RR intervals), pupil reflex, and salivation as parameters, but the interrelation between each parameter and fNIRS measures remains unknown. We were to investigate the relationship in response to established paradigms using simultaneously each parameter-fNIRS recording in healthy human subjects. Analysis of fNIRS was examined by a comparison of various values between before and after various stimuli (89 Hz-S, 114 Hz-S, listen to classic music, and “Ahh” vocalization). We confirmed that vibrotactile stimulation (89 Hz) of the parotid glands led to the greatest salivation, greatest increase in heart rate variability, and the most constricted pupils. Furthermore, there were almost no detectable differences between fNIRS during 89 Hz-S and fNIRS during listening to classical music of fans. Thus, vibrotactile stimulation of 89 Hz seems to evoke parasympathetic activity. PMID:24511550
NASA Astrophysics Data System (ADS)
Van Huffel, Sabine; Craemers, Johan; Lenaerts, Bart; Daniels, Hans; Naulaers, Gunnar; Casaer, Paul
1998-12-01
The objective of this study is to evaluate the effect of episodes of apneas and/or mild bradycardia (heart rate decreases of 10 to 20% or more) on cerebral oxyhemoglobin (HbO2) and reduced hemoglobin (Hb) concentration as measured by Near Infrared Spectrophotometry (NIRS). Measurements were carried out on 7 preterm infants who experienced apneic and bradycardiac events. It is shown how to characterize these events using time-frequency analysis. In addition to NIRS (performed with a NIRO-500 from Hamamatsu, Japan), the heart rate, ECG, peripheral arterial oxygen saturation (measured at the foot) and respiration (abdominal and thoracic pressure, and nasal airflow) were continuously recorded. The impact of apneic events and periodic breathing on these measurements reveals the clinical relevance of NIRS. In particular, we investigate whether these changes in heart rate and respiration also influence HbO2 and reduced Hb concentration in neonatal brain. These changes are characterized, as well as their relationships with the other simultaneously recorded signals such as peripheral arterial oxygen saturation.
Psychophysiological Correlates of Generalized Anxiety Disorder with or without Comorbid Depression
Hofmann, Stefan G.; Schulz, Stefan M.; Heering, Sanna; Muench, Frederick; Bufka, Lynn F.
2010-01-01
It remains uncertain whether generalized anxiety disorder (GAD) and major depressive disorder (MDD) represent two separate diagnostic entities. The goal of this study was to examine whether comorbid MDD distinguishes individuals with GAD on a psychophysiological level during an experimentally-induced worrying procedure. Participants included 39 individuals with GAD, 14 of whom met criteria for MDD. During the experimental procedure, participants were asked to worry or relax after an initial baseline phase while measuring their heart rate, high frequency heart rate variability (HF-HRV), skin conductance level, and subjective level of anxiety. The two groups did not differ in their subjective anxiety, heart rate response, and skin conductance levels. However, participants with comorbid MDD had greater HF-HRV values throughout the experiment than did those without MDD. At baseline, HF-HRV was significantly correlated with a self-report measure of depression. These results suggest that individuals with comorbid GAD and MDD can be distinguished based on HF-HRV from individuals with GAD but without MDD. These results support the distinction between GAD and MDD. PMID:20093149
Heart rate variability is associated with social value orientation in males but not females.
Lischke, Alexander; Mau-Moeller, Anett; Jacksteit, Robert; Pahnke, Rike; Hamm, Alfons O; Weippert, Matthias
2018-05-09
Phylogenetic and neurobiological theories suggest that inter-individual differences in high frequency heart rate variability (HF-HRV) are associated with inter-individual differences in social behavior and social cognition. To test these theories, we investigated whether individuals with high and low HF-HRV would show different preferences for cooperative behavior in social contexts. We recorded resting state HF-HRV in 84 healthy individuals before they completed the Social Value Orientation task, a well-established measure of cooperative preferences. HF-HRV was derived from short-term (300 s) and ultra-short-term (60 s, 120 s) recordings of participants' heart rate to determine the robustness of possible findings. Irrespective of recording length, we found a sex-dependent association between inter-individual differences in HF-HRV and inter-individual differences in social value orientation: The preference for cooperation was more pronounced among individuals with high as compared low HF-HRV, albeit only in male and not in female participants. These findings suggest that males with high HF-HRV are more inclined to engage in cooperative behavior than males with low HF-HRV.
Heart rate variability (HRV) during virtual reality immersion
Malińska, Marzena; Zużewicz, Krystyna; Bugajska, Joanna; Grabowski, Andrzej
2015-01-01
The goal of the study was assessment of the hour-long training involving handling virtual environment (sVR) and watching a stereoscopic 3D movie on the mechanisms of autonomic heart rate (HR) regulation among the subjects who were not predisposed to motion sickness. In order to exclude predispositions to motion sickness, all the participants (n=19) underwent a Coriolis test. During an exposure to 3D and sVR the ECG signal was continuously recorded using the Holter method. For the twelve consecutive 5-min epochs of ECG signal, the analysis of heart rate variability (HRV) in time and frequency domains was conducted. After 30 min from the beginning of the training in handling the virtual workstation a significant increase in LF spectral power was noted. The values of the sympathovagal LF/HF index while sVR indicated a significant increase in sympathetic predominance in four time intervals, namely between the 5th and the 10th minute, between the 15th and the 20th minute, between the 35th and 40th minute and between the 55th and the 60th minute of exposure. PMID:26327262
Effect of Methamphetamine Dependence on Heart Rate Variability
Henry, Brook L.; Minassian, Arpi; Perry, William
2010-01-01
Background Methamphetamine (METH) is an increasing popular and highly addictive stimulant associated with autonomic nervous system (ANS) dysfunction, cardiovascular pathology, and neurotoxicity. Heart rate variability (HRV) has been used to assess autonomic function and predict mortality in cardiac disorders and drug intoxication, but has not been characterized in METH use. We recorded HRV in a sample of currently abstinent individuals with a history of METH dependence compared to age- and gender-matched drug-free comparison subjects. Method HRV was assessed using time domain, frequency domain, and nonlinear entropic analyses in 17 previously METH-dependent and 21 drug-free comparison individuals during a 5 minute rest period. Results The METH-dependent group demonstrated significant reduction in HRV, reduced parasympathetic activity, and diminished heartbeat complexity relative to comparison participants. More recent METH use was associated with increased sympathetic tone. Conclusion Chronic METH exposure may be associated with decreased HRV, impaired vagal function, and reduction in heart rate complexity as assessed by multiple methods of analysis. We discuss and review evidence that impaired HRV may be related to the cardiotoxic or neurotoxic effects of prolonged METH use. PMID:21182570
Bombardini, Tonino; Gemignani, Vincenzo; Bianchini, Elisabetta; Pasanisi, Emilio; Pratali, Lorenza; Pianelli, Mascia; Faita, Francesco; Giannoni, Massimo; Arpesella, Giorgio; Sicari, Rosa; Picano, Eugenio
2009-01-01
Background New sensors for intelligent remote monitoring of the heart should be developed. Recently, a cutaneous force-frequency relation recording system has been validated based on heart sound amplitude and timing variations at increasing heart rates. Aim To assess sensor-based post-exercise contractility, diastolic function and pressure in normal and diseased hearts as a model of a wireless telemedicine system. Methods We enrolled 150 patients and 22 controls referred for exercise-stress echocardiography, age 55 ± 18 years. The sensor was attached in the precordial region by an ECG electrode. Stress and recovery contractility were derived by first heart sound amplitude vibration changes; diastolic times were acquired continuously. Systemic pressure changes were quantitatively documented by second heart sound recording. Results Interpretable sensor recordings were obtained in all patients (feasibility = 100%). Post-exercise contractility overshoot (defined as increase > 10% of recovery contractility vs exercise value) was more frequent in patients than controls (27% vs 8%, p < 0.05). At 100 bpm stress heart rate, systolic/diastolic time ratio (normal, < 1) was > 1 in 20 patients and in none of the controls (p < 0.01); at recovery systolic/diastolic ratio was > 1 in only 3 patients (p < 0.01 vs stress). Post-exercise reduced arterial pressure was sensed. Conclusion Post-exercise contractility, diastolic time and pressure changes can be continuously measured by a cutaneous sensor. Heart disease affects not only exercise systolic performance, but also post-exercise recovery, diastolic time intervals and blood pressure changes – in our study, all of these were monitored by a non-invasive wearable sensor. PMID:19442285
Machado, Marcus Vinicius; Vieira, Aline Bomfim; da Conceição, Fabiana Gomes; Nascimento, Alessandro Rodrigues; da Nóbrega, Antonio Claudio Lucas; Tibirica, Eduardo
2017-12-01
What is the central question of this study? Regular exercise is recommended as a non-pharmacological approach for the prevention and treatment of metabolic syndrome. However, the impact of different combinations of intensity, duration and frequency of exercise on metabolic syndrome and microvascular density has not been reported. What is the main finding and its importance? We provide evidence on the impact of aerobic exercise dose on metabolic and microvascular alterations in an experimental model of metabolic syndrome induced by high-fat diet. We found that the exercise frequency and duration were the main factors affecting anthropometric and metabolic parameters and microvascular density in the skeletal muscle. Exercise intensity was related only to microvascular density in the heart. We evaluated the effect of the frequency, duration and intensity of exercise training on metabolic parameters and structural capillary density in obese rats with metabolic syndrome. Wistar-Kyoto rats were fed either a standard commercial diet (CON) or a high-fat diet (HFD). Animals that received the HFD were randomly separated into either a sedentary (SED) group or eight different exercise groups that varied according to the frequency, duration and intensity of training. After 12 weeks of aerobic exercise training, the body composition, aerobic capacity, haemodynamic variables, metabolic parameters and capillary density in the heart and skeletal muscle were evaluated. All the exercise training groups showed reduced resting systolic blood pressure and heart rate and normalized fasting glucose. The minimal amount of exercise (90 min per week) produced little effect on metabolic syndrome parameters. A moderate amount of exercise (150 min per week) was required to reduce body weight and improve capillary density. However, only the high amount of exercise (300 min per week) significantly reduced the amount of body fat depots. The three-way ANOVA showed a main effect of exercise frequency and duration for the improvement of metabolic syndrome and capillary density in skeletal muscle. Exercise intensity was a main factor in reversing microvascular rarefaction in the heart. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
The effects of extra-low-frequency atmospheric pressure oscillations on human mental activity
NASA Astrophysics Data System (ADS)
Delyukov, A. A.; Didyk, L.
Slight atmospheric pressure oscillations (APO) in the extra-low-frequency range below 0.1 Hz, which frequently occur naturally, can influence human mental activity. This phenomenon has been observed in experiments with a group of 12 healthy volunteers exposed to experimentally created APO with amplitudes 30-50 Pa in the frequency band 0.011-0.17 Hz. Exposure of the subjects to APO for 15-30 min caused significant changes in attention and short-term memory functions, performance rate, and mental processing flexibility. The character of the response depended on the APO frequency and coherence. Periodic APO promoted purposeful mental activity, accompanied by an increase in breath-holding duration and a slower heart rate. On the other hand, quasi-chaotic APO, similar to the natural perturbations of atmospheric pressure, disrupted mental activity. These observations suggest that APO could be partly responsible for meteorosensitivity in humans.
Effects of guided breath exercise on complex behaviour of heart rate dynamics.
Tavares, Bruna S; de Paula Vidigal, Giovanna; Garner, David M; Raimundo, Rodrigo D; de Abreu, Luiz Carlos; Valenti, Vitor E
2017-11-01
Cardiac autonomic regulation is influenced by changes in respiratory rate, which has been demonstrated by linear analysis of heart rate variability (HRV). Conversely, the complex behaviour is not well defined for HRV during this physiological state. In this sense, Higuchi Fractal Dimension is applied directly to the time series. It analyses the fractal dimension of discrete time sequences and is simpler and faster than correlation dimension and many other classical measures derived from chaos theory. We investigated chaotic behaviour of heart rate dynamics during guided breath exercises. We investigated 21 healthy male volunteers aged between 18 and 30 years. HRV was analysed 10 min before and 10 min during guided breath exercises. HRV was analysed in the time and frequency domain for linear analysis and through HFD for non-linear analysis. Linear analysis indicated that SDNN, pNN50, RMSSD, LF, HF and LF/HF increased during guided breath exercises. HFD analysis illustrated that between K max 20 to K max 120 intervals, was enhanced during guided breath exercises. Guided breath exercises acutely increased chaotic behaviour of HRV measured by HFD. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Fetal heart rate patterns at 20 to 24 weeks gestation as recorded by fetal electrocardiography
Hofmeyr, F; Groenewald, CA; Nel, DG; Myers, MM; Fifer, WP; Signore, C; Hankins, GDV; Odendaal, HJ
2014-01-01
Introduction With advancing technology it has become possible to accurately record and assess fetal heart rate (FHR) patterns from gestations as early as 20 weeks. The aim of our study was to describe early patterns of FHR, as recorded by transabdominal fetal electrocardiogram according to the Dawes-Redman criteria. Accordingly, short-term variability, basal heart rate, accelerations and decelerations were quantified at 20-24 weeks gestation among women with uncomplicated pregnancies. Methods This study was conducted in a subset of participants enrolled in a large prospective pregnancy cohort study. Our final data set consisted of 281 recordings of women with good perinatal outcomes that had undergone fetal electrocardiographic assessment as part of the Safe Passage Study. Results The success rate of the recordings was 95.4%. The mean frequency of small and large accelerations was 0.5 and 0.1 per 10 minutes respectively and that of small and large decelerations 0.3 and 0.008 per 10 minutes respectively. The mean and basal heart rates were both equal to 148.0 bpm at a median gestation of 161 days. The mean short term variation was 6.2 (SD 1.4) milliseconds and mean minute range 35.1 (SD 7.1) milliseconds. Conclusion The 20 to 24 week fetus demonstrates FHR patterns with more accelerations and decelerations, as well as higher baseline variability than was anticipated. Information from this study provides an important foundation for further, more detailed, studies of early FHR patterns. PMID:23991757
Important influence of respiration on human R-R interval power spectra is largely ignored
NASA Technical Reports Server (NTRS)
Brown, T. E.; Beightol, L. A.; Koh, J.; Eckberg, D. L.
1993-01-01
Frequency-domain analyses of R-R intervals are used widely to estimate levels of autonomic neural traffic to the human heart. Because respiration modulates autonomic activity, we determined for nine healthy subjects the influence of breathing frequency and tidal volume on R-R interval power spectra (fast-Fourier transform method). We also surveyed published literature to determine current practices in this burgeoning field of scientific inquiry. Supine subjects breathed at rates of 6, 7.5, 10, 15, 17.1, 20, and 24 breaths/min and with nominal tidal volumes of 1,000 and 1,500 ml. R-R interval power at respiratory and low (0.06-0.14 Hz) frequencies declined significantly as breathing frequency increased. R-R interval power at respiratory frequencies was significantly greater at a tidal volume of 1,500 than 1,000 ml. Neither breathing frequency nor tidal volume influenced average R-R intervals significantly. Our review of studies reporting human R-R interval power spectra showed that 51% of the studies controlled respiratory rate, 11% controlled tidal volume, and 11% controlled both respiratory rate and tidal volume. The major implications of our analyses are that breathing parameters strongly influence low-frequency as well as respiratory frequency R-R interval power spectra and that this influence is largely ignored in published research.
Moltedo, Jose M.; Iyer, Ramesh V.; Forman, Howard; Fahey, John; Rosenthal, Geoffrey; Snyder, Christopher S.
2006-01-01
Background: In Wolff-Parkinson-White syndrome (WPW) patients the loss of pre-excitation in a single heartbeat during exercise stress testing (EST) is a predictor of low risk of sudden death. The purpose of this study was to: 1) assess the frequency of loss of pre-excitation in a single heartbeat during exercise testing, and 2) compare the cost of EST versus trans-catheter electrophysiology study (EPS) in the risk assessment of WPW patients. Methods: A retrospective review of 50 cases of patients with WPW who underwent EST was conducted including demographics, history of supraventricular tachycardia, associated congenital heart disease, maximum heart rate achieved, and loss of pre-excitation in a single heartbeat. Hospital costs of EST and EPS were compared. Results: Of the 50 patients who underwent EST, 4 (8%), lost pre-excitation in a single heartbeat during EST. No differences were found regarding gender, age at diagnosis or EST, history of supraventricular tachycardia, presence of congenital heart disease or maximal heart rate. A cost comparison, utilizing the cost data: EST ($62.75) and EPS ($5,597) found EST to be a cost-saving approach in WPW patients. With 4 patients losing pre-excitation during EST, the cost saving of EST was $22,388 for this population of WPW patients. Conclusions: A frequency of 8% loss of pre-excitation was found in a pediatric sample that underwent EST. Additionally, EST was shown to be a cost-saving strategy in risk assessment of pediatric WPW patients. PMID:21845141
Heart Rate Variability Indexes in Dementia: A Systematic Review with a Quantitative Analysis.
da Silva, Vanessa Pereira; Ramalho Oliveira, Bruno Ribeiro; Tavares Mello, Roger Gomes; Moraes, Helena; Deslandes, Andrea Camaz; Laks, Jerson
2018-01-01
Decreased heart rate variability (HRV) indexes indicate low vagal activity and may be associated with development of dementia. The neurodegenerative process is associated with the cardiovascular autonomic control. The aim of this systematic review was to investigate the effect size (ES) magnitude of the HRV indexes in the evaluation of autonomic dysfunction in older persons with dementia. PubMed (Medline), Web of Science, Scopus, Scielo, Lilacs, and APA Psycnet were consulted. Complete original articles published in English or Portuguese, investigating the association between autonomic dysfunction and dementia, using the HRV indexes were included. The search identified 97 potentially relevant articles. After screening the full text, eight articles were included in the qualitative analysis and six were included in the quantitative analysis. Almost all indexes showed a negative ES for all types of dementia and mild cognitive impairment. The most common frequency band of the power spectrum density function was the high frequency, which was reported by six studies. The meta-analysis of high frequency power in Alzheimer's disease group showed high heterogeneity and inconsistent results. The negative effect size suggests an autonomic dysfunction in all types of dementia as well as mild cognitive impairment. However, further analysis is necessary to support these results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Yijing, Zhang; Xiaoping, Du; Fang, Liu; Xiaolu, Jing; Bin, Wu
2015-01-01
Objectives. The present study aimed to investigate the effects of guided imagery training on heart rate variability in individuals while performing spaceflight emergency tasks. Materials and Methods. Twenty-one student subjects were recruited for the experiment and randomly divided into two groups: imagery group (n = 11) and control group (n = 10). The imagery group received instructor-guided imagery (session 1) and self-guided imagery training (session 2) consecutively, while the control group only received conventional training. Electrocardiograms of the subjects were recorded during their performance of nine spaceflight emergency tasks after imagery training. Results. In both of the sessions, the root mean square of successive differences (RMSSD), the standard deviation of all normal NN (SDNN), the proportion of NN50 divided by the total number of NNs (PNN50), the very low frequency (VLF), the low frequency (LF), the high frequency (HF), and the total power (TP) in the imagery group were significantly higher than those in the control group. Moreover, LF/HF of the subjects after instructor-guided imagery training was lower than that after self-guided imagery training. Conclusions. Guided imagery was an effective regulator for HRV indices and could be a potential stress countermeasure in performing spaceflight tasks. PMID:26137491
Experimental investigation of fan-folded piezoelectric energy harvesters for powering pacemakers
Ansari, M H; Karami, M Amin
2018-01-01
This paper studies the fabrication and testing of a magnet free piezoelectric energy harvester (EH) for powering biomedical devices and sensors inside the body. The design for the EH is a fan-folded structure consisting of bimorph piezoelectric beams folding on top of each other. An actual size experimental prototype is fabricated to verify the developed analytical models. The model is verified by matching the analytical results of the tip acceleration frequency response functions (FRF) and voltage FRF with the experimental results. The generated electricity is measured when the EH is excited by the heartbeat. A closed loop shaker system is utilized to reproduce the heartbeat vibrations. Achieving low fundamental natural frequency is a key factor to generate sufficient energy for pacemakers using heartbeat vibrations. It is shown that the natural frequency of the small-scale device is less than 20 Hz due to its unique fan-folded design. The experimental results show that the small-scale EH generates sufficient power for state of the art pacemakers. The 1 cm3 EH with18.4 gr tip mass generates more than16 μW of power from a normal heartbeat waveform. The robustness of the device to the heart rate is also studied by measuring the relation between the power output and the heart rate. PMID:29674807
Analysis of cardiac signals using spatial filling index and time-frequency domain
Faust, Oliver; Acharya U, Rajendra; Krishnan, SM; Min, Lim Choo
2004-01-01
Background Analysis of heart rate variation (HRV) has become a popular noninvasive tool for assessing the activities of the autonomic nervous system (ANS). HRV analysis is based on the concept that fast fluctuations may specifically reflect changes of sympathetic and vagal activity. It shows that the structure generating the signal is not simply linear, but also involves nonlinear contributions. These signals are essentially non-stationary; may contain indicators of current disease, or even warnings about impending diseases. The indicators may be present at all times or may occur at random in the time scale. However, to study and pinpoint abnormalities in voluminous data collected over several hours is strenuous and time consuming. Methods This paper presents the spatial filling index and time-frequency analysis of heart rate variability signal for disease identification. Renyi's entropy is evaluated for the signal in the Wigner-Ville and Continuous Wavelet Transformation (CWT) domain. Results This Renyi's entropy gives lower 'p' value for scalogram than Wigner-Ville distribution and also, the contours of scalogram visually show the features of the diseases. And in the time-frequency analysis, the Renyi's entropy gives better result for scalogram than the Wigner-Ville distribution. Conclusion Spatial filling index and Renyi's entropy has distinct regions for various diseases with an accuracy of more than 95%. PMID:15361254
Experimental investigation of fan-folded piezoelectric energy harvesters for powering pacemakers.
Ansari, M H; Karami, M Amin
2017-06-01
This paper studies the fabrication and testing of a magnet free piezoelectric energy harvester (EH) for powering biomedical devices and sensors inside the body. The design for the EH is a fan-folded structure consisting of bimorph piezoelectric beams folding on top of each other. An actual size experimental prototype is fabricated to verify the developed analytical models. The model is verified by matching the analytical results of the tip acceleration frequency response functions (FRF) and voltage FRF with the experimental results. The generated electricity is measured when the EH is excited by the heartbeat. A closed loop shaker system is utilized to reproduce the heartbeat vibrations. Achieving low fundamental natural frequency is a key factor to generate sufficient energy for pacemakers using heartbeat vibrations. It is shown that the natural frequency of the small-scale device is less than 20 Hz due to its unique fan-folded design. The experimental results show that the small-scale EH generates sufficient power for state of the art pacemakers. The 1 cm 3 EH with18.4 gr tip mass generates more than16 μ W of power from a normal heartbeat waveform. The robustness of the device to the heart rate is also studied by measuring the relation between the power output and the heart rate.
Chang, Hsin-An; Chang, Chuan-Chia; Kuo, Terry B J; Huang, San-Yuan
2015-01-01
Bipolar II (BPII) depression is commonly misdiagnosed as unipolar depression (UD); however, an objective and reliable tool to differentiate between these disorders is lacking. Whether cardiac autonomic function can be used as a biomarker to distinguish BPII from UD is unknown. We recruited 116 and 591 physically healthy patients with BPII depression and UD, respectively, and 421 healthy volunteers aged 20-65 years. Interviewer and self-reported measures of depression/anxiety severity were obtained. Cardiac autonomic function was evaluated by heart rate variability (HRV) and frequency-domain indices of HRV. Patients with BPII depression exhibited significantly lower mean R-R intervals, variance (total HRV), low frequency (LF)-HRV, and high frequency (HF)-HRV but higher LF/HF ratio compared to those with UD. The significant differences remained after adjusting for age. Compared to the controls, the patients with BPII depression showed cardiac sympathetic excitation with reciprocal vagal impairment, whereas the UD patients showed only vagal impairment. Depression severity independently contributed to decreased HRV and vagal tone in both the patients with BPII depression and UD, but increased sympathetic tone only in those with BPII depression. HRV may aid in the differential diagnosis of BPII depression and UD as an adjunct to diagnostic interviews.
The marine mammal dive response is exercise modulated to maximize aerobic dive duration.
Davis, Randall W; Williams, Terrie M
2012-08-01
When aquatically adapted mammals and birds swim submerged, they exhibit a dive response in which breathing ceases, heart rate slows, and blood flow to peripheral tissues and organs is reduced. The most intense dive response occurs during forced submersion which conserves blood oxygen for the brain and heart, thereby preventing asphyxiation. In free-diving animals, the dive response is less profound, and energy metabolism remains aerobic. However, even this relatively moderate bradycardia seems diametrically opposed to the normal cardiovascular response (i.e., tachycardia and peripheral vasodilation) during physical exertion. As a result, there has been a long-standing paradox regarding how aquatic mammals and birds exercise while submerged. We hypothesized based on cardiovascular modeling that heart rate must increase to ensure adequate oxygen delivery to active muscles. Here, we show that heart rate (HR) does indeed increase with flipper or fluke stroke frequency (SF) during voluntary, aerobic dives in Weddell seals (HR = 1.48SF - 8.87) and bottlenose dolphins (HR = 0.99SF + 2.46), respectively, two marine mammal species with different evolutionary lineages. These results support our hypothesis that marine mammals maintain aerobic muscle metabolism while swimming submerged by combining elements of both dive and exercise responses, with one or the other predominating depending on the level of exertion.
Understanding heart rate alarm adjustment in the intensive care units through an analytical approach
Pelter, Michele M.; Drew, Barbara J.; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J. Matt; Hu, Xiao
2017-01-01
Background Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. Objectives To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Methods Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). Results There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). Conclusions HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision. PMID:29176776
O'Keefe, James H; Abuissa, Hussam; Sastre, Antonio; Steinhaus, David M; Harris, William S
2006-04-15
We explored possible mechanisms by which recommended intakes of omega-3 fatty acids may decrease the risk for sudden cardiac death in patients with documented coronary heart disease. The cardioprotective effects of omega-3 fatty acids have been documented in epidemiologic and randomized controlled trials. These fatty acids are presumed to decrease susceptibility to fatal arrhythmias, but whether this is mediated by classic risk factors or direct cardiac mechanisms is not known. Eighteen white men with a history of myocardial infarction and ejection fractions <40% were randomized to placebo or omega-3 fatty acids (585 mg of docosahexaenoic acid and 225 mg of eicosapentaenoic acid) for two 4-month periods in a crossover design. At the end of each period, heart rate (HR), HR variability, and rate of HR recovery after exercise were determined, as were effects on arterial compliance, blood pressure, cardiac function, and fasting serum levels of lipids and inflammatory markers. Omega-3 fatty acids decreased HR at rest from 73 +/- 13 to 68 +/- 13 beats/min (p <0.0001) and improved 1-minute HR recovery after exercise (-27 +/- 10 to -32 +/- 12 beats/min, p <0.01). HR variability in the high-frequency band increased (p <0.02), but no change was noted in overall HR variability. There were no significant effects on blood pressure, arterial compliance, lipids, or inflammatory markers. These changes are consistent with an increase in vagal activity and may in part explain the observed decrease in risk for sudden cardiac death seen with omega-3 fatty acid supplementation.
Combat Stress Decreases Memory of Warfighters in Action.
Delgado-Moreno, Rosa; Robles-Pérez, José Juan; Clemente-Suárez, Vicente Javier
2017-08-01
The present research aimed to analyze the effect of combat stress in the psychophysiological response and attention and memory of warfighters in a simulated combat situation. Variables of blood oxygen saturation, heart rate, blood glucose, blood lactate, body temperature, lower body muscular strength manifestation, cortical arousal, autonomic modulation, state anxiety and memory and attention through a postmission questionnaire were analyzed before and after a combat simulation in 20 male professional Spanish Army warfighters. The combat simulation produces a significant increase (p < 0.05) in explosive leg strength, rated perceived exertion, blood glucose, blood lactate, somatic anxiety, heart rate, and low frequency domain of the HRV (LF) and a significant decrease of high frequency domain of the heart rate variability (HF). The percentage of correct response in the postmission questionnaire parameters show that elements more related with a physical integrity threat are the most correctly remembered. There were significant differences in the postmission questionnaire variables when participants were divided by the cortical arousal post: sounds no response, mobile phone correct, mobile phone no response, odours correct. The correlation analysis showed positive correlations: LF post/body temperature post, HF post/correct sound, body temperature post/glucose post, CFFTpre/lactate post, CFFT post/wrong sound, glucose post/AC pre, AC post/wrong fusil, AS post/SC post and SC post/wrong olfactory; and negative correlations: LF post/correct sound, body temperature post/lactate post and glucose post/lactate post. This data suggest that combat stress actives fight-flight system of soldiers. As conclusion, Combat stress produces an increased psychophysiological response that cause a selective decrease of memory, depending on the nature, dangerous or harmless of the objects.
1982-02-01
fragile data bases. With correction of this deficiency and further research on time sharing behavior or function interlacing, these methods should prove to...parameLers used were (1) amplitude - as a measure of amplitude variations, the difference between two successive heart rate values- tk2 ) frequency - as a
Autonomic Regulation on the Stroop Predicts Reading Achievement in School Age Children
ERIC Educational Resources Information Center
Becker, Derek R.; Carrere, Sybil; Siler, Chelsea; Jones, Stephanie; Bowie, Bonnie; Cooke, Cheryl
2012-01-01
In this study we examined high frequency heart rate variability (HF-HRV, a parasympathetic index) both at rest and during challenge, to assess if variations in cardiovascular activity measured during a Stroop task could be used to predict reading achievement in typically developing children. Reading achievement was examined using the Peabody…
USDA-ARS?s Scientific Manuscript database
Circadian rhythms in cardiovascular physiology (e.g. blood pressure and heart rate) and pathophysiology (e.g. myocardial infarction (MI)) exist. Humans exhibit a marked increase in MI frequency during the early hours of the morning. However, MIs occurring during the evening are more likely to result...
Cardiotachometer displays heart rate on a beat-to-beat basis
NASA Technical Reports Server (NTRS)
Rasquin, J. R.; Smith, H. E.; Taylor, R. A.
1974-01-01
Electronics for this system may be chosen so that complete calculation and display may be accomplished in a few milliseconds, far less than even the fastest heartbeat interval. Accuracy may be increased, if desired, by using higher-frequency timing oscillator, although this will require large capacity registers at increased cost.
Effort reward imbalance is associated with vagal withdrawal in Danish public sector employees.
Eller, Nanna Hurwitz; Blønd, Morten; Nielsen, Martin; Kristiansen, Jesper; Netterstrøm, Bo
2011-09-01
The current study analyzed the relationship between psychosocial work environment assessed by the Effort Reward Imbalance Model (ERI-model) and heart rate variability (HRV) measured at baseline and again, two years later, as this relationship is scarcely covered by the literature. Measurements of HRV during seated rest were obtained from 231 public sector employees. The associations between the ERI-model, and HRV were examined using a series of mixed effects models. The dependent variables were the logarithmically transformed levels of HRV-measures. Gender and year of measurement were included as factors, whereas age, and time of measurement were included as covariates. Subject was included as a random effect. Effort and effort reward imbalance were positively associated with heart rate and the ratio between low frequency (LF) and high frequency power (HF) and negatively associated with total power (TP) and HF. Reward was positively associated with TP. Adverse psychosocial work environment according to the ERI-model was associated with HRV, especially in the form of vagal withdrawal and most pronounced in women. Copyright © 2011 Elsevier B.V. All rights reserved.
Richard, C A; Waldrop, T G; Bauer, R M; Mitchell, J H; Stremel, R W
1989-03-13
It is known that muscle afferents and the hypothalamic locomotor region (HLR) both project to the nucleus reticularis gigantocellularis (NGC) and that the NGC is capable of influencing cardiovascular and respiratory variables. Therefore, the role of NGC in the cardiovascular and respiratory response to exercise-related signals was investigated in anesthetized cats. These signals were generated by stimulation of: (1) spinal ventral roots to induce hindlimb muscle contraction (MC) and (2) the HLR. Bilateral electrolytic lesion of the NGC at the pontomedullary border caused tidal volume, respiratory frequency and heart rate responses to HLR stimulation to be greater than the responses recorded prior to lesioning. Lesioning had no effect on the ventilatory or cardiovascular responses to MC but did decrease phrenic responsiveness; lesion had no effect on any resting values. In this preparation, the pontomedullary NGC acts as an inhibitory influence on tidal volume, breathing frequency and heart rate responses to the central command for exercise. In addition, NGC modulation of ventilation would appear to be selective for certain respiratory muscle groups.
Billeci, Lucia; Tartarisco, Gennaro; Brunori, Elena; Crifaci, Giulia; Scardigli, Silvia; Balocchi, Rita; Pioggia, Giovanni; Maestro, Sandra; Morales, Maria Aurora
2015-03-01
Bradycardia and abnormal cardiac autonomic function are related to increased mortality in anorexia nervosa (AN). The aim of this study was to assess heart rate (HR) and HR variability of young adolescents with AN as compared to controls by means of wearable sensors and wireless technologies. The ECG signal was recorded in 27 AN girls and 15 healthy girls at rest using a wearable chest strap. The tachogram, the mean intervals between R peaks (meanRR), the root mean square of successive differences (RMSSD), the power of low-frequency (LF) and high-frequency (HF) bands and the LF/HF ratio were assessed. All AN girls showed a reduced HR and an increased meanRR and RMSSD. An HF increase, a LF decrease, and a LF/HF reduction indicated a prevalence of the parasympathetic on sympathetic activity. The instruments used in this pilot study were feasible, unobtrusive and extremely suitable in AN subjects who are burdened by high incidence of cardiovascular mortality; their application could open to new approaches of vital signs monitoring in hospitals as well as in home settings.
Milsom, William K
2012-12-01
The location (gills, oro-branchial cavity or elsewhere) and orientation (external (water) or internal (blood) sensing) of the receptors involved in reflex changes in each of the different components of the cardiorespiratory response (breathing frequency, breath amplitude, heart rate, systemic vascular resistance) to hypoxia and hypercarbia are highly variable between species of water and air breathing fish. Although not universal, the receptors involved in eliciting changes in heart rate and breathing frequency in response to hypoxia and hypercarbia tend to be restricted exclusively to the gills while those producing increases in breath amplitude are more wide spread, frequently also being found at extrabranchial sites. The distribution of the chemoreceptors sensitive to CO(2) in the gills involved in producing ventilatory responses tend to be more restricted than that of the O(2)-sensitive chemoreceptors and the specific location of the receptors involved in the various components of the cardiorespiratory response can vary from those of the O(2)-sensitive chemoreceptors. Copyright © 2012 Elsevier B.V. All rights reserved.
Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms
NASA Technical Reports Server (NTRS)
Schlegel, Todd T.; Arenare, Brian
2006-01-01
A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present method is the presence versus the absence of reduced-amplitude zones (RAZs). In terms that must be simplified for the sake of brevity, an RAZ comprises several cycles of a high-frequency QRS signal during which the amplitude of the high-frequency oscillation in a portion of the signal is abnormally low (see figure). A given signal sample exhibiting an interval of reduced amplitude may or may not be classified as an RAZ, depending on quantitative criteria regarding peaks and troughs within the reduced-amplitude portion of the high-frequency QRS signal. This analysis is performed in all 12 leads in real time.
Heart rate variability in workers of various professions in contrasting seasons of the year.
Markov, Alexander; Solonin, Iuriy; Bojko, Evgeniy
2016-01-01
It is known that professional occupation affects the heart rate variability (HRV). However, most studies have not taken into account seasonal features of the HRV. The aim of this study has been to evaluate the HRV differences in winter and in summer in the case of the Ministry of the Russian Federation for Civil Defense, Emergencies and Elimination of Consequences of Natural Disasters (EMERCOM) workers and scientific workers from the Komi Science Center of the Ural Branch of the Russian Academy of Sciences. The short-term HRV was examined for 13 EMERCOM workers and 13 scientific workers. The data was collected in winter (December) and summer (July) for the same groups of workers. The time domain and frequency domain HRV analyses were performed. The EMERCOM workers had more contact with the external environment than the scientific workers. The two-way analysis of variance with repeated observations on a single factor has shown that "Season" and interaction of two factors "Season" and "Profession" significantly influenced the HRV among volunteers. The "Profession" factor did not influence the HRV parameters (except for the heart rate in winter, p = 0.042). Seasonal changes in the HRV parameters were not significant in the case of scientific workers. In contrast, the EMERCOM workers showed significantly decreased parameters of parasympathetic activity (the root-mean-square of successive differences in RR intervals, percentage of consecutive RR intervals differing by > 50 ms and the relative value high frequency power, p = 0.001, p = 0.014 and p = 0.009, respectively) and increased parameters of sympathetic activity (the stress index and ratio of low-frequency power to high-frequency power, p = 0.012 and p = 0.006, respectively) in winter as compared to summer. The results of our study indicate that, unlike the scientific workers, the EMERCOM workers showed significant changes in the HRV in contrasting seasons (winter and summer). A season of a year should be considered when assessing the HRV among workers of various professions. Int J Occup Med Environ Health 2016;29(5):793-800. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Babaoğlu, Kadir; Deveci, Murat; Kayabey, Özlem; Altun, Gürkan; Binnetoğlu, Köksal
2015-03-01
Childhood obesity has increased in the last half of the century. The aim of this study was to evaluate the frequency of obesity in the children with congenital or acquired heart disease. A total of 1410 children were assessed in this study. The study population was composed of 518 children (289 boys, 229 girls) as control group and 892 children (477 boys, 415 girls) as heart disease group. Patients were grouped into four categories: (I) "Clinic control subjects"; (II) "mild heart disease" that has not been treated with either surgical or catheter intervention; (III) congenital heart disease treated with surgical and/or catheter intervention; and (IV) "arrhythmias". A body mass index ⩾85th percentile was defined as overweight, ⩾95th percentile as obese, and <5th percentile was defined as underweight. We did not detect any association between heart disease and obesity. There was no difference in the rates of overweight, obesity, and underweight between the healthy control subjects and patients with heart disease (8.1%, 13.3%, and 5.0%; 9.0%, 10.7%, and 4.7%, respectively, p=0.145). All subgroups had a similar prevalence of underweight, overweight, and obesity as the healthy control population. Within the heart disease population, the overall prevalence rates for overweight, obesity, and underweight were similar between the boys and girls. Obesity is a common problem in children with heart disease, at least in general population. It is an important additional risk factor for long-term cardiovascular morbidity and mortality in children with heart disease. Precautions to prevent obesity should be a part of paediatric cardiologist's examination.
Effect of Listening to the Al-Quran on Heart Sound
NASA Astrophysics Data System (ADS)
Daud, N. F.; Sharif, Z.
2018-03-01
This paper investigates the effect on the heart sounds upon listening to the chosen verses of the Al Quran. A signal of the heart sounds is extracted using Thinklabs Phonocardiography software and then the frequency components are extracted using MATLAB 7.11.0. Frequency components during diastolic are compared for two sessions; before and during listening sessions. Diastolic is a period where the chamber of the heart is filled with the blood when the heart muscle is in a relaxed condition. From this study, it is found that the frequency of the heart sound during listening to Al-Quran is lower than the one before listening to Al-Quran. This indicates that, the state of calmness can be achieved by listening to this selected verses of the Al-Quran.
Mapping cardiogenic oscillations using synchrotron-based phase contrast CT imaging
NASA Astrophysics Data System (ADS)
Thurgood, Jordan; Dubsky, Stephen; Siu, Karen K. W.; Wallace, Megan; Siew, Melissa; Hooper, Stuart; Fouras, Andreas
2012-10-01
In many animals, including humans, the lungs encase the majority of the heart thus the motion of each organ affects the other. The effects of the motion of the heart on the lungs potentially provides information with regards to both lung and heart health. We present a novel technique that is capable of measuring the effect of the heart on the surrounding lung tissue through the use of advanced synchrotron imaging techniques and recently developed X-ray velocimetry methods. This technique generates 2D frequency response maps of the lung tissue motion at multiple projection angles from projection X-ray images. These frequency response maps are subsequently used to generate 3D reconstructions of the lung tissue exhibiting motion at the frequency of ventilation and the lung tissue exhibiting motion at the frequency of the heart. This technique has a combined spatial and temporal resolution sufficient to observe the dynamic and complex 3D nature of lung-heart interactions.
Haverinen, Jaakko; Abramochkin, Denis V; Kamkin, Andre; Vornanen, Matti
2017-02-01
Temperature-induced changes in cardiac output (Q̇) in fish are largely dependent on thermal modulation of heart rate (f H ), and at high temperatures Q̇ collapses due to heat-dependent depression of f H This study tests the hypothesis that firing rate of sinoatrial pacemaker cells sets the upper thermal limit of f H in vivo. To this end, temperature dependence of action potential (AP) frequency of enzymatically isolated pacemaker cells (pacemaker rate, f PM ), spontaneous beating rate of isolated sinoatrial preparations (f SA ), and in vivo f H of the cold-acclimated (4°C) brown trout (Salmo trutta fario) were compared under acute thermal challenges. With rising temperature, f PM steadily increased because of the acceleration of diastolic depolarization and shortening of AP duration up to the break point temperature (T BP ) of 24.0 ± 0.37°C, at which point the electrical activity abruptly ceased. The maximum f PM at T BP was much higher [193 ± 21.0 beats per minute (bpm)] than the peak f SA (94.3 ± 6.0 bpm at 24.1°C) or peak f H (76.7 ± 2.4 at 15.7 ± 0.82°C) (P < 0.05). These findings strongly suggest that the frequency generator of the sinoatrial pacemaker cells does not limit f H at high temperatures in the brown trout in vivo. Copyright © 2017 the American Physiological Society.
Medenwald, Daniel; Swenne, Cees A; Frantz, Stefan; Nuding, Sebastian; Kors, Jan A; Pietzner, Diana; Tiller, Daniel; Greiser, Karin H; Kluttig, Alexander; Haerting, Johannes
2017-12-01
To assess the value of cardiac structure/function in predicting heart rate variability (HRV) and the possibly predictive value of HRV on cardiac parameters. Baseline and 4-year follow-up data from the population-based CARLA cohort were used (790 men, 646 women, aged 45-83 years at baseline and 50-87 years at follow-up). Echocardiographic and HRV recordings were performed at baseline and at follow-up. Linear regression models with a quadratic term were used. Crude and covariate adjusted estimates were calculated. Missing values were imputed by means of multiple imputation. Heart rate variability measures taken into account consisted of linear time and frequency domain [standard deviation of normal-to-normal intervals (SDNN), high-frequency power (HF), low-frequency power (LF), LF/HF ratio] and non-linear measures [detrended fluctuation analysis (DFA1), SD1, SD2, SD1/SD2 ratio]. Echocardiographic parameters considered were ventricular mass index, diastolic interventricular septum thickness, left ventricular diastolic dimension, left atrial dimension systolic (LADS), and ejection fraction (Teichholz). A negative quadratic relation between baseline LADS and change in SDNN and HF was observed. The maximum HF and SDNN change (an increase of roughly 0.02%) was predicted at LADS of 3.72 and 3.57 cm, respectively, while the majority of subjects experienced a decrease in HRV. There was no association between further echocardiographic parameters and change in HRV, and there was no evidence of a predictive value of HRV in the prediction of changes in cardiac structure. In the general population, LADS predicts 4-year alteration in SDNN and HF non-linearly. Because of the novelty of the result, analyses should be replicated in other populations. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.
Resting and postexercise heart rate variability in professional handball players.
Kayacan, Yildirim; Yildiz, Sedat
2016-03-01
The aim of this study was to evaluate heart rate variability (HRV) in professional handball players during rest and following a 5 min mild jogging exercise. For that purpose, electrocardiogram (ECG) of male handball players (N.=12, mean age 25±3.95 years) and sedentary controls (N.=14, mean age 23.5±2.95 years) were recorded for 5 min at rest and just after 5 min of mild jogging. ECGs were recorded and following HRV parameters were calculated: time-domain variables such as heart rate (HR), average normal-to-normal RR intervals, standard deviation of normal-to-normal RR intervals, square root of the mean of the squares of differences between adjacent NN intervals, percentage of differences between adjacent NN intervals that are greater than 50 milliseconds (pNN50), and frequency-domain variables such as very low frequency, low (LF) and high frequency (HF) of the power and LF/HF ratio. Unpaired t-test was used to find out differences among groups while paired t-test was used for comparison of each group for pre- and postjogging HRV. Pearson correlations were carried out to find out the relationships between the parameters. Blood pressures were not different between handball players and sedentary controls but exercise increased systolic blood pressure (P<0.01). HR was increased with exercise (P<0.001) and was slower in handball players (P<0.01). QTc was increased with exercise (P<0.001) and was higher in handball players (P<0.001). Exercise decreased pNN50 values in both groups but LF/HF ratio increased only in sedentary subjects. In conclusion, results of the HRV parameters show that sympathovagal balance does not appear to change in handball players in response to a mild, short-time (5 min) jogging exercise. However, in sedentary subjects, either the sympathetic regulation of the autonomous nervous system increased or vagal withdrawal occurred.