Local time distribution of the SSC-associated HF-Doppler frequency shifts
NASA Technical Reports Server (NTRS)
Kikuchi, T.; Sugiuchi, H.; Ishimine, T.
1985-01-01
The HF-Doppler frequency shift observed at the storm's sudden commencement is composed of a frequency increase (+) and decrease (-), and classified into four types, SCF(+ -), SCF(- +), SCF(+) and SCF(-). Since the latter two types are special cases of the former two types, two different kinds of electrical field exist in the F region and cause the ExB drift motion of plasma. HUANG (1976) interpreted the frequency increase of SCF(+ -) as due to the westward induction electric field proportional to delta H/ delta t and the succeeding frequency decrease due to the eastward conduction electric field which produces ionospheric currents responsible for the magnetic increase on the ground. In spite of his success in interpreting the SCF(+ -), some other interpretations are needed for the explanation of the whole set of SCF's, particularly SCF(- +). Local time distributions of the SCF's are derived from 41 SCF's which are observed on the HF standard signal (JJY) as received in Okinawa (path length =1600 km) and Kokubunji (60 km). It is shown that the SCF(+ -) appears mainly during the day, whereas the SCF(- +) is observed during the night. The results indicate that the preliminary frequency shift (+) of SCF(+ -) and (-) of SCF(- +) is caused by a westward electric field in the dayside hemisphere, while by an eastward electric field in the nightside hemisphere. The main frequency shift (-) of SCF(+ -) and (+) of SCF(- +) is caused by the reversed electric field. Consequently, the preliminary frequency shift is caused by the dusk-to-dawn electric field, while the main frequency shift by the dawn-to-dusk electric field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toriyama, Koichi; Oguchi, Akihide; Morinaga, Atsuo
2011-12-15
We investigate the phenomenon that a Berry phase evolving linearly in time induces a frequency shift of the resonance transition between two eigenstates, regardless of whether or not they are superposed. Using the magnetic-field-insensitive two-photon microwave--radio-frequency transition, which is free of any other dynamical frequency shift, we demonstrate that the frequency shift caused by a uniform rotation of the magnetic field corresponds to the derivative of the Berry phase with respect to time and depends on the direction of rotation of the magnetic field.
Initial atomic coherences and Ramsey frequency pulling in fountain clocks
NASA Astrophysics Data System (ADS)
Gerginov, Vladislav; Nemitz, Nils; Weyers, Stefan
2014-09-01
In the uncertainty budget of primary atomic cesium fountain clocks, evaluations of frequency-pulling shifts of the hyperfine clock transition caused by unintentional excitation of its nearby transitions (Rabi and Ramsey pulling) have been based so far on an approach developed for cesium beam clocks. We re-evaluate this type of frequency pulling in fountain clocks and pay particular attention to the effect of initial coherent atomic states. We find significantly enhanced frequency shifts caused by Ramsey pulling due to sublevel population imbalance and corresponding coherences within the state-selected hyperfine component of the initial atom ground state. Such shifts are experimentally investigated in an atomic fountain clock and quantitative agreement with the predictions of the model is demonstrated.
Pressure broadening and frequency shift of the D 1 and D 2 lines of K in the presence of Ne and Kr
NASA Astrophysics Data System (ADS)
Wang, Xulin; Chen, Yao; Quan, Wei; Chi, Haotian; Fang, Jiancheng
2018-02-01
We present the results of pressure broadening and frequency shift of K D 1 and D 2 lines in presence of 1-4 amg of Neon gas and 1-5 amg of Krypton gas by laser absorption spectroscopy. Both pressure broadening and frequency shift are linearly related to gas density with high accuracy. The asymmetry of the absorption line shape caused by van der Waals potential was first found in the near-line wings of large density Kr in the experiment. We have also investigated the temperature dependence of the pressure broadening and frequency shift in a range of 353-403 K in Neon and 373-417 K in Krypton and compared the results of the pressure broadening and frequency shift with previous values.
Low-Light-Shift Cesium Fountain without Mechanical Shutters
NASA Technical Reports Server (NTRS)
Enzer, Daphna
2008-01-01
A new technique for reducing errors in a laser-cooled cesium fountain frequency standard provides for strong suppression of the light shift without need for mechanical shutters. Because mechanical shutters are typically susceptible to failure after operating times of the order of months, the elimination of mechanical shutters could contribute significantly to the reliability of frequency standards that are required to function continuously for longer time intervals. With respect to the operation of an atomic-fountain frequency standard, the term "light shift" denotes an undesired relative shift in the two energy levels of the atoms (in this case, cesium atoms) in the atomic fountain during interrogation by microwaves. The shift in energy levels translates to a frequency shift that reduces the precision and possibly accuracy of the frequency standard. For reasons too complex to describe within the space available for this article, the light shift is caused by any laser light that reaches the atoms during the microwave- interrogation period, but is strongest for near-resonance light. In the absence of any mitigating design feature, the light shift, expressed as a fraction of the standard fs frequency, could be as large as approx. 2 x 10(exp -11), the largest error in the standard. In a typical prior design, to suppress light shift, the intensity of laser light is reduced during the interrogation period by using a single-pass acoustooptic modulator to deflect the majority of light away from the main optical path. Mechanical shutters are used to block the remaining undeflected light to ensure complete attenuation. Without shutters, this remaining undeflected light could cause a light shift of as much as .10.15, which is unacceptably large in some applications. The new technique implemented here involves additionally shifting the laser wavelength off resonance by a relatively large amount (typically of the order of nanometers) during microwave interrogation. In this design, when microwave interrogation is not underway, the atoms are illuminated by a slave laser locked to the lasing frequency of a lower power master laser.
Plasma modification of spoof plasmon propagation along metamaterial-air interfaces
NASA Astrophysics Data System (ADS)
Lee, R.; Wang, B.; Cappelli, M. A.
2017-12-01
We report on measurements of the shift in resonance frequency of "spoof" surface plasmon polariton propagation along a 2-D metamaterial slow-wave structure induced by a gaseous plasma near the metamaterial/air interface. A transmission line circuit model for the metamaterial structure interprets the introduction of a plasma as a decrease in unit cell capacitance, causing a shift in the plasmon dispersion to higher frequency. We show through simulations and experiments that the effects of this shift at the resonance frequency and attenuation below and above resonance depend on the plasma density. The shifts recorded experimentally are small owing to the low plasma densities generated near the structure, ˜ 10 11 cm - 3 , but simulations show that a shift of ˜ 3 % of the resonance frequency can be generated at plasma densities of ˜ 10 12 cm - 3 .
Frequency Shift During Mass Properties Testing Using Compound Pendulum Method
NASA Technical Reports Server (NTRS)
Wolfe, David; Regan, Chris
2012-01-01
During mass properties testing on the X-48B Blended Wing Body aircraft (The Boeing Company, Chicago, Illinois) at the National Aeronautics and Space Administration Dryden Flight Research Center, Edwards, California, large inertia measurement errors were observed in results from compound pendulum swings when compared to analytical models. By comparing periods of oscillations as measured from an average over the test period versus the period of each oscillation, it was noticed that the frequency of oscillation was shifting significantly throughout the test. This phenomenon was only noticed during compound pendulum swings, and not during bifilar pendulum swings. The frequency shift was only visible upon extensive data analysis of the frequency for each oscillation, and did not appear in averaged frequency data over the test period. Multiple test articles, test techniques, and hardware setups were used in attempts to eliminate or identify the cause of the frequency shift. Plotting the frequency of oscillation revealed a region of minimal shift that corresponded to a larger amplitude range. This region of minimal shift provided the most accurate results compared to a known test article; however, the amplitudes that produce accurate inertia measurements are amplitudes larger than those generally accepted in mass properties testing. This paper examines two case studies of the frequency shift, using mass properties testing performed on a dummy test article, and on the X-48B Blended Wing Body aircraft.
Driven acoustic oscillations within a vertical magnetic field
NASA Technical Reports Server (NTRS)
Hindman, Bradley W.; Zweibel, Ellen G.; Cally, P. S.
1995-01-01
The effects of a vertical magnetic field on p-mode frequencies, line widths, and eigenfunctions, are examined. A solar model, consisting of a neutrally stable polytropic interior matched to an isothermal chromosphere, is applied. The p-modes are produced by a spatially distributed driver. The atmosphere is threaded by a constant vertical magnetic field. The frequency shifts due to the vertical magnetic field are found to be much smaller than the shifts caused by horizontal fields of similar strength. A large vertical field of 2000 G produces shifts of several nHz. It is found that the frequency shifts decrease with increasing frequency and increase with field strength. The coupling of the acoustic fast mode to the escaping slow modes is inefficient. Constant vertical magnetic field models are therefore incapable of explaining the high level of absorption observed in sunspots and plage.
Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity
Parise, M.
2018-05-18
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less
Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parise, M.
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less
Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity
NASA Astrophysics Data System (ADS)
Parise, M.
2018-05-01
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effective tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.
Prediction of the Lorentz Force Detuning and Pressure Sensitivity for a Pillbox Cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parise, M.
2018-04-23
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less
Stockman, Andrew; Henning, G Bruce; West, Peter; Rider, Andrew T; Ripamonti, Caterina
2017-08-01
When M- or L-cone-isolating sawtooth waveforms flicker at frequencies between 4 and 13.3 Hz, there is a mean hue shift in the direction of the shallower sawtooth slope. Here, we investigate how this shift depends on the alignment of the first and second harmonics of sawtooth-like waveforms. Below 4 Hz, observers can follow hue variations caused by both harmonics, and reliably match reddish and greenish excursions. At higher frequencies, however, the hue variations appear as chromatic flicker superimposed on a steady light, the mean hue of which varies with second-harmonic alignment. Observers can match this mean hue against a variable-duty-cycle rectangular waveform and, separately, set the alignment at which the mean hue flips between reddish and greenish. The maximum hue shifts were approximately frequency independent and occurred when the peaks or troughs of the first and second harmonics roughly aligned at the visual input-consistent with the hue shift's being caused by an early instantaneous nonlinearity that saturates larger hue excursions. These predictions, however, ignore phase delays introduced within the chromatic pathway between its input and the nonlinearity that produces the hue shifts. If the nonlinearity follows the substantial filtering implied by the chromatic temporal contrast-sensitivity function, phase delays will alter the alignment of the first and second harmonics such that at the nonlinearity, the waveforms that produce the maximum hue shifts might well be those with the largest differences in rising and falling slopes-consistent with the hue shift's being caused by a central nonlinearity that limits the rate of hue change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foullon, C.; Nakariakov, V. M.
2010-05-01
The discovery that p-mode frequencies of low degree do not follow changes of solar surface activity during the recent solar minimum offers the possibility of a new diagnostic signature of the responsible pressure perturbation in the wave guiding medium, potentially rich of information regarding the structure of the Sun and the cause of the unusually long solar minimum. Magnetic fields, as well as temperature changes, introduce equilibrium pressure deviations that modify the resonant frequencies of p-mode oscillations. Assuming the perturbation to be caused by a horizontal layer of magnetic field located in a plane-stratified model of the Sun, we compilemore » analytical frequency shifts and process them to allow direct comparison with observations. The effect of magnetism itself on the central p-mode frequencies can be neglected in comparison with the thermal effect of a perturbative layer buried in the solar interior. A parametric study shows that a layer as thin as 2100 km at subsurface depths is able to reproduce reported mean anomalous frequency shifts (not correlated with the surface activity), while a layer of size around 4200 km increasing by a small amount at depths near 0.08 R {sub sun} can explain individual low-degree shifts. It is also possible to obtain the mean shifts via the upward motion through depths near 0.03 R {sub sun} of a rising perturbative layer of thickness around 7000 km. Hence, the anomalous frequency shifts are best explained by thermal effects in the upper regions of the convection zone. The effects of latitudinal distribution are not treated here.« less
Interpreting Quasi-Thermal Effects in Ultrafast Spectroscopy of Hydrogen-Bonded Systems.
Stingel, Ashley M; Petersen, Poul B
2018-03-15
Vibrational excitation of molecules in the condensed phase relaxes through vibrational modes of decreasing energy to ultimately generate an equilibrium state in which the energy is distributed among low-frequency modes. In ultrafast vibrational spectroscopy, changes in the vibrational features of hydrogen-bonded NH and OH stretch modes are typically observed to persist long after these high-frequency vibrations have relaxed. Due to the resemblance to the spectral changes caused by heating the sample, these features are typically described as arising from a hot ground state. However, these spectral features appear on ultrafast time scales that are much too fast to result from a true thermal state, and significant differences between the thermal difference spectrum and the induced quasi-thermal changes in ultrafast spectroscopy are often observed. Here, we examine and directly compare the thermal and quasi-thermal responses of the hydrogen-bonded homodimer of 7-azaindole with temperature-dependent FTIR spectroscopy and ultrafast mid-IR continuum spectroscopy. We find that the thermal difference spectra contain contributions from both dissociation of the hydrogen bonds and from frequency shifts due to changes in the thermal population of low-frequency modes. The transient spectra in ultrafast vibrational spectroscopy are also found to contain two contributions: initial frequency shifts over 2.3 ± 0.11 ps associated with equilibration of the initial excitation, and frequency shifts associated with the excitation of several fingerprint modes, which decay over 21.8 ± 0.11 ps, giving rise to a quasi-thermal response caused by a distribution of fingerprint modes being excited within the sample ensemble. This resembles the thermal frequency shifts due to population changes of low-frequency modes, but not the overall thermal spectrum, which is dominated by features caused by dimer dissociation. These findings provide insight into the changes in the vibrational spectrum from different origins and are important for assigning, analyzing, and comparing features in thermal and ultrafast vibrational spectroscopy of hydrogen-bonded complexes.
New ion trap for atomic frequency standard applications
NASA Technical Reports Server (NTRS)
Prestage, J. D.; Dick, G. J.; Maleki, L.
1989-01-01
A novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the radio frequency (RF) confining fields has been designed and built. This new trap should store about 20 times the number of ions a conventional RF trap stores with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.
Electro-optic-waveguide frequency translator in LiNbO(3) fabricated by proton exchange.
Wong, K K; De La Rue, R M; Wright, S
1982-11-01
An optical waveguide phase modulator has been fabricated on X-cut LiNbO(3) by using proton exchange in benzoic acid. The phase modulator was operated as a serrodyne optical-frequency translator with shifted-signal to imagesignal discrimination of 52 dB for a 4-MHz frequency shift. The amplitude of the sawtooth driving signal was 10 V peak to peak. Application of a de bias voltage of either polarity was found to cause a substantial reduction in transmitted-light intensity.
On the physical origin of blue-shifted hydrogen bonds.
Li, Xiaosong; Liu, Lei; Schlegel, H Bernhard
2002-08-14
For blue-shifted hydrogen-bonded systems, the hydrogen stretching frequency increases rather than decreases on complexation. In computations at various levels of theory, the blue-shift in the archetypical system, F(3)C-H.FH, is reproduced at the Hartree-Fock level, indicating that electron correlation is not the primary cause. Calculations also demonstrate that a blue-shift does not require either a carbon center or the absence of a lone pair on the proton donor, because F(3)Si-H.OH(2), F(2)NH.FH, F(2)PH.NH(3), and F(2)PH.OH(2) have substantial blue-shifts. Orbital interactions are shown to lengthen the X-H bond and lower its vibrational frequency, and thus cannot be the source of the blue-shift. In the F(3)CH.FH system, the charge redistribution in F(3)CH can be reproduced very well by replacing the FH with a simple dipole, which suggests that the interactions are predominantly electrostatic. When modeled with a point charge for the proton acceptor, attractive electrostatic interactions elongate the F(3)C-H, while repulsive interactions shorten it. At the equilibrium geometry of a hydrogen-bonded complex, the electrostatic attraction between the dipole moments of the proton donor and proton acceptor must be balanced by the Pauli repulsion between the two fragments. In the absence of orbital interactions that cause bond elongation, this repulsive interaction leads to compression of the X-H bond and a blue-shift in its vibrational frequency.
Amplitude-frequency effect of Y-cut langanite and langatate.
Kim, Yoonkee
2003-12-01
Amplitude-frequency effect of a Y-cut langanite (LGN) resonator and a Y-cut langatate (LGT) resonator were measured. The frequency shifts from the baseline frequency with 1 mA were measured as a function of drive currents up to 28 mA. High-drive current shifted the frequency, but it also heated the crystal locally, causing temperature-related frequency changes. The local heat transfer and its influence on the frequency were analyzed. The amplitude-frequency shift was effectively measured, and was not affected by the temperature-related frequency changes. The 3rd, 5th, and 7th overtones (OT's) were found to behave as soft springs, i.e., resonant frequency decreases as drive current increases. The drive sensitivity coefficients of the 3rd and 5th OT's are in the vicinity of -2 ppb/mA2 for both resonators. The 7th OT's are higher than the other OT's: -5 approximately -7 ppb/mA2. The lowest drive sensitivity is -1.2 ppb/mA2 on the 5th OT of the LGT.
Acoustic levitation and the Boltzmann-Ehrenfest principle
NASA Technical Reports Server (NTRS)
Putterman, S.; Rudnick, Joseph; Barmatz, M.
1989-01-01
The Boltzmann-Ehrenfest principle of adiabatic invariance relates the acoustic potential acting on a sample positioned in a single-mode cavity to the shift in resonant frequency caused by the presence of this sample. This general and simple relation applies to samples and cavities of arbitrary shape, dimension, and compressibility. Positioning forces and torques can, therefore, be determined from straightforward measurements of frequency shifts. Applications to the Rayleigh disk phenomenon and levitated cylinders are presented.
NASA Astrophysics Data System (ADS)
Brandt, N. N.; Chikishev, A. Yu.; Dolgovskii, V. I.; Lebedenko, S. I.
2007-09-01
The effect of solvent on low-frequency oscillations is studied using an example of the 1,1,2,2-tetrachloroethane (TCE) and 1,1,2,2-tetrabromoethane (TBE) molecules, which exhibit torsional oscillations in the terahertz range. Dimethylsulfoxide (DMSO) and carbon tetrachloride (CTC) are used as solvents. It is demonstrated that a decrease in the concentration of the substance under study in the TBE/CTC, TCE/DMSO, and TCE/CTC mixtures leads to a frequency shift of the low-frequency oscillation. The shift is not observed in the TBE/DMSO mixture but a decrease in the TBE concentration causes significant broadening of the low-frequency line.
NASA Astrophysics Data System (ADS)
Yuya, Philip A.; Wen, Yongkui; Turner, Joseph A.; Dzenis, Yuris A.; Li, Zheng
2007-03-01
The authors report a technique for measuring Young's modulus of a single electrospun nanofiber using the vibrations of two microcantilevers coupled with the nanofiber. The modulus is calculated from the resonant frequency shift resulting from the nanofiber. Polyacrylonitrile nanofibers (200nm diameter) were collected during electrospinning and wrapped on two similar microcantilevers causing a shift in first resonance from 10.0to19.4kHz. Finite element analysis was used to analyze the frequency shift using images from a scanning electron microscope giving a modulus of the as-spun polyacrylonitrile nanofiber of 26.8GPa.
Santillan, Arturo O; Cutanda-Henríquez, Vicente
2008-11-01
An investigation on the resonance frequency shift for a plane-wave mode in a cylindrical cavity produced by a rigid sphere is reported in this paper. This change of the resonance frequency has been previously considered as a cause of oscillational instabilities in single-mode acoustic levitation devices. It is shown that the use of the Boltzmann-Ehrenfest principle of adiabatic invariance allows the derivation of an expression for the resonance frequency shift in a simpler and more direct way than a method based on a Green's function reported in literature. The position of the sphere can be any point along the axis of the cavity. Obtained predictions of the resonance frequency shift with the deduced equation agree quite well with numerical simulations based on the boundary element method. The results are also confirmed by experiments. The equation derived from the Boltzmann-Ehrenfest principle appears to be more general, and for large spheres, it gives a better approximation than the equation previously reported.
Night-shift work and breast cancer risk in a cohort of Chinese women.
Pronk, Anjoeka; Ji, Bu-Tian; Shu, Xiao-Ou; Xue, Shouzheng; Yang, Gong; Li, Hong-Lan; Rothman, Nathaniel; Gao, Yu-Tang; Zheng, Wei; Chow, Wong-Ho
2010-05-01
Shift work involving disruption of circadian rhythms has been classified as a probable cause of human cancer by the International Agency for Research on Cancer, based on limited epidemiologic evidence and abundant experimental evidence. The authors investigated this association in a population-based prospective cohort study of Chinese women. At baseline (1996-2000), information on lifetime occupational history was obtained from 73,049 women. Lifetime night-shift exposure indices were created using a job exposure matrix. During 2002-2004, self-reported data on frequency and duration of night-shift work were collected. Hazard ratios and 95% confidence intervals, adjusted for major breast cancer risk factors, were calculated. During follow-up through 2007, 717 incident cases of breast cancer were diagnosed. Breast cancer risk was not associated with ever working the night shift on the basis of the job exposure matrix (adjusted hazard ratio = 1.0, 95% confidence interval: 0.9, 1.2) or self-reported history of night-shift work (adjusted hazard ratio = 0.9, 95% confidence interval: 0.7, 1.1). Risk was also not associated with frequency, duration, or cumulative amount of night-shift work. There were no indications of effect modification. The lack of an association between night-shift work and breast cancer adds to the inconsistent epidemiologic evidence. It may be premature to consider shift work a cause of cancer.
Attenuation analysis of real GPR wavelets: The equivalent amplitude spectrum (EAS)
NASA Astrophysics Data System (ADS)
Economou, Nikos; Kritikakis, George
2016-03-01
Absorption of a Ground Penetrating Radar (GPR) pulse is a frequency dependent attenuation mechanism which causes a spectral shift on the dominant frequency of GPR data. Both energy variation of GPR amplitude spectrum and spectral shift were used for the estimation of Quality Factor (Q*) and subsequently the characterization of the subsurface material properties. The variation of the amplitude spectrum energy has been studied by Spectral Ratio (SR) method and the frequency shift by the estimation of the Frequency Centroid Shift (FCS) or the Frequency Peak Shift (FPS) methods. The FPS method is more automatic, less robust. This work aims to increase the robustness of the FPS method by fitting a part of the amplitude spectrum of GPR data with Ricker, Gaussian, Sigmoid-Gaussian or Ricker-Gaussian functions. These functions fit different parts of the spectrum of a GPR reference wavelet and the Equivalent Amplitude Spectrum (EAS) is selected, reproducing Q* values used in forward Q* modeling analysis. Then, only the peak frequencies and the time differences between the reference wavelet and the subsequent reflected wavelets are used to estimate Q*. As long as the EAS is estimated, it is used for Q* evaluation in all the GPR section, under the assumption that the selected reference wavelet is representative. De-phasing and constant phase shift, for obtaining symmetrical wavelets, proved useful in the sufficiency of the horizons picking. Synthetic, experimental and real GPR data were examined in order to demonstrate the effectiveness of the proposed methodology.
Young, Laura K; Smithson, Hannah E
2014-01-01
There is evidence that letter identification is mediated by only a narrow band of spatial frequencies and that the center frequency of the neural channel thought to underlie this selectivity is related to the size of the letters. When letters are spatially filtered (at a fixed size) the channel tuning characteristics change according to the properties of the spatial filter (Majaj et al., 2002). Optical aberrations in the eye act to spatially filter the image formed on the retina-their effect is generally to attenuate high frequencies more than low frequencies but often in a non-monotonic way. We might expect the change in the spatial frequency spectrum caused by the aberration to predict the shift in channel tuning observed for aberrated letters. We show that this is not the case. We used critical-band masking to estimate channel-tuning in the presence of three types of aberration-defocus, coma and secondary astigmatism. We found that the maximum masking was shifted to lower frequencies in the presence of an aberration and that this result was not simply predicted by the spatial-frequency-dependent degradation in image quality, assessed via metrics that have previously been shown to correlate well with performance loss in the presence of an aberration. We show that if image quality effects are taken into account (using visual Strehl metrics), the neural channel required to model the data is shifted to lower frequencies compared to the control (no-aberration) condition. Additionally, we show that when spurious resolution (caused by π phase shifts in the optical transfer function) in the image is masked, the channel tuning properties for aberrated letters are affected, suggesting that there may be interference between visual channels. Even in the presence of simulated aberrations, whose properties change from trial-to-trial, observers exhibit flexibility in selecting the spatial frequencies that support letter identification.
Relativistic effects in earth-orbiting Doppler lidar return signals.
Ashby, Neil
2007-11-01
Frequency shifts of side-ranging lidar signals are calculated to high order in the small quantities (v/c), where v is the velocity of a spacecraft carrying a lidar laser or of an aerosol particle that scatters the radiation back into a detector (c is the speed of light). Frequency shift measurements determine horizontal components of ground velocity of the scattering particle, but measured fractional frequency shifts are large because of the large velocities of the spacecraft and of the rotating earth. Subtractions of large terms cause a loss of significant digits and magnify the effect of relativistic corrections in determination of wind velocity. Spacecraft acceleration is also considered. Calculations are performed in an earth-centered inertial frame, and appropriate transformations are applied giving the velocities of scatterers relative to the ground.
Pearce, Jeffrey D.; Craven, Timothy E.; Edwards, Matthew S.; Corriere, Matthew A.; Crutchley, Teresa A.; Fleming, Shawn H.; Hansen, Kimberley J.
2010-01-01
Background Atherosclerotic renovascular disease is associated with an increased risk of cardiovascular disease (CVD) events. This study examines associations between Doppler-derived parameters from the renal artery and renal parenchyma and all-cause mortality and fatal and nonfatal CVD events in a cohort of elderly Americans. Study Design Cohort study. Setting A subset of participants from the Cardiovascular Health Study (CHS). Through an ancillary study, 870 (70% recruitment) Forsyth County, NC, CHS participants consented to undergo renal duplex sonography to define the prevalence of renovascular disease in the elderly, resulting in 726 (36% men; mean age, 77 years) technically adequate complete studies included in this investigation. Predictor Renal duplex sonography–derived Doppler signals from the main renal arteries and renal parenchyma. Spectral analysis from Doppler-shifted frequencies and angle of insonation were used to estimate renal artery peak systolic and end diastolic velocity (both in meters per second). Color Doppler was used to identify the corticomedullary junction. Using a 3-mm Doppler sample, the parenchymal peak systolic and end diastolic frequency shift (both in kilohertz) were obtained. Resistive index was calculated as (1 – [end diastolic frequency shift/peak systolic frequency shift]) using Doppler samples from the hilar arteries of the left or right kidney with the higher main renal artery peak systolic velocity. Outcomes & Measurements Proportional hazard regression analysis was used to determine associations between renal duplex sonography–derived Doppler signals and CVD events and all-cause mortality adjusted for accepted cardiovascular risk factors. Index CVD outcomes were defined as coronary events (angina, myocardial infarction, and coronary artery bypass grafting/percutaneous coronary intervention), cerebrovascular events (stroke or transient ischemic attack), and any CVD event (angina, congestive heart failure, myocardial infarction, stroke, transient ischemic attack, and coronary artery bypass grafting [CABG]/percutaneous transluminal coronary intervention [PTCI]). Results During follow-up, 221 deaths (31%), 229 CVD events (32%), 122 coronary events (17%), and 92 cerebrovascular events (13%) were observed. Renal duplex sonography–derived Doppler signals from the renal parenchyma were associated independently with all-cause mortality and CVD outcomes. In particular, increased parenchymal end diastolic frequency shift was associated significantly with any CVD event (HR, 0.73; 95% CI, 0.62-0.87; P < 0.001). Marginally significant associations were observed between increases in parenchymal end diastolic frequency shift and decreased risk of death (HR, 0.86; 95% CI, 0.73-1.00; P = 0.06) and decreased risk of cerebrovascular events (HR, 0.78; 95% CI, 0.61-1.01; P = 0.06). Parenchymal end diastolic frequency shift was not significantly predictive of coronary events (HR, 0.84; 95% CI, 0.67-1.06; P = 0.1). Limitations CHS participants showed a “healthy cohort” effect that may underestimate the rate of CVD events in the general population. Conclusion Renal duplex sonographic Doppler signals from the renal parenchyma showed significant associations with subsequent CVD events after controlling for other significant risk factors. In particular, a standard deviation increase in parenchymal end diastolic frequency shift was associated with 27% risk reduction in any CVD event. PMID:20116688
The effect of cockpit noise on the temporary threshold shift of Cessna 172SP flight instructors
NASA Astrophysics Data System (ADS)
Bellini, Andrew Robert
The purpose of this thesis was to study the temporary threshold shift of general aviation flight instructors resulting from their working environment. Exposure to noise before a temporary threshold shift completely recovers can cause a permanent threshold shift with no possibility of recovery, resulting in permanent hearing loss. A result showing minimal to no temporary threshold shift would indicate that hearing personal protective equipment is working properly. This study used sound-level measurements, and audiometric testing, together with survey data to determine whether or not flight instructors were at risk for potential hearing impairment due to temporary threshold shift. Independent t-tests and descriptive statistics were used in analyzing the data. It was determined that there was a difference in temporary threshold shift based on the number of hours a flight instructor flies in a Cessna 172SP for only one frequency - 2000Hz in the left ear. All other frequencies tested in both ears showed no difference. Because there was a very low mean temporary threshold shift at 2000Hz in the left ear and no differences shown for all other frequencies in both ears, it was concluded that there was no need to improve or require additional hearing personal protective equipment, or to require decreased exposure times to aircraft noise.
NASA Astrophysics Data System (ADS)
Rozanov, N. N.; Kiselev, Al. S.; Kiselev, An. S.
2008-08-01
Self-reflection of pulses of intense laser radiation from an inhomogeneity induced by them in a medium with fast optical nonlinearity is analyzed. The reflected radiation is characterized by a considerable Doppler shift and by a signal magnitude that is sufficient for experimental detection.
Yüce, Emre; Ctistis, Georgios; Claudon, Julien; Gérard, Jean-Michel; Vos, Willem L
2016-01-11
We have switched GaAs/AlAs and AlGaAs/AlAs planar microcavities that operate in the "Original" (O) telecom band by exploiting the instantaneous electronic Kerr effect. We observe that the resonance frequency reversibly shifts within one picosecond when the nanostructure is pumped with low-energy photons. We investigate experimentally and theoretically the role of several parameters: the material backbone and its electronic bandgap, the quality factor, and the duration of the switch pulse. The magnitude of the frequency shift is reduced when the backbone of the central λ-layer has a greater electronic bandgap compared to the cavity resonance frequency and the frequency of the pump. This observation is caused by the fact that pumping with photon energies near the bandgap resonantly enhances the switched magnitude. We thus find that cavities operating in the telecom O-band are more amenable to ultrafast Kerr switching than those operating at lower frequencies, such as the C-band. Our results indicate that the large bandgap of AlGaAs/AlAs cavity allows to tune both the pump and the probe to the telecom range to perform Kerr switching without detrimental two-photon absorption. We observe that the magnitude of the resonance frequency shift decreases with increasing quality factor of the cavity. Our model shows that the magnitude of the resonance frequency shift depends on the pump pulse duration and is maximized when the duration matches the cavity storage time to within a factor two. In our experiments, we obtain a maximum shift of the cavity resonance relative to the cavity linewidth of 20%. We project that the shift of the cavity resonance can be increased twofold with a pump pulse duration that better matches the cavity storage time. We provide the essential parameter settings for different materials so that the frequency shift of the cavity resonance can be maximized using the electronic Kerr effect.
Light shift measurements in a Cesium Fountain without the use of mechanical shutters
NASA Technical Reports Server (NTRS)
Tjoelker, Robert L.; Enzer, D. G.; Klipstein, W. M.
2005-01-01
We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.
NASA Astrophysics Data System (ADS)
Shmatukha, Andriy V.; Bakker, Chris J. G.
2006-05-01
Respiratory Induced Resonance Offset (RIRO) is a periodic disturbance of the magnetic field due to breathing. Such disturbances handicap the accuracy of the Proton Resonance Frequency Shift (PRFS) method of MRI temperature mapping in anatomies situated nearby the lungs and chest wall. In this work, we propose a method capable of minimizing errors caused by RIRO in PRFS temperature maps. In this method, a set of baseline images characterizing RIRO at a variety of respiratory cycle instants is acquired before the thermal treatment starts. During the treatment, the temperature evolution is found from two successive images. Then, the calculated temperature changes are corrected for the additional contribution caused by RIRO using the pre-treatment baseline images acquired at the identical instances of the respiratory cycle. Our method is shown to improve the accuracy and stability of PRFS temperature maps in the presence of RIRO and motion in phantom and volunteer experiments.
NASA Astrophysics Data System (ADS)
Lee, Seung Seok; Kim, Ju Ha; Choi, Eun Seo
2017-04-01
We proposed novel phase-shifting interferometry using a fiber-optic vibration sensor. The Doppler shift in the coiled fiber caused by vibrations can be used to detect the vibrations by using a fiber-optic interferometer. The principle can be applied to induce phase shifts. While applying vibrations to the coiled fiber at various vibration frequencies, we recorded the variations in the interference fringes. The interference fringe moved to longer wavelengths when a vibration frequency was increased from 38.00 to 38.40 kHz. Phase variations of 3.59 rad/kHz were obtained. The ability to accurately control the phase by using the vibrations in the coiled fiber was demonstrated by the elimination of the depth degeneracy using the complex signal generated by the phase-shifted interference fringes. Using vibrations to control phase shifting can be an acceptable alternative to conventional methods and can be applied to resolve the depth ambiguity in Fourier domain optical coherence tomography.
The centrifugal force reversal and X-ray bursts
NASA Astrophysics Data System (ADS)
Abramowicz, M. A.; Kluźniak, W.; Lasota, J. P.
2001-08-01
Heyl (2000) made an interesting suggestion that the observed shifts in QPO frequency in type I X-ray bursts could be influenced by the same geometrical effect of strong gravity as the one that causes centrifugal force reversal discovered by Abramowicz & Lasota (1974). However, his main result contains a sign error. Here we derive the correct formula and conclude that constraints on the M(R) relation for neutron stars deduced from the rotational-modulation model of QPO frequency shifts are of no practical interest because the correct formula implies a weak condition R* > 1.3 RS, where RS is the Schwarzschild radius. We also argue against the relevance of the rotational-modulation model to the observed frequency modulations.
Inertial mass sensing with low Q-factor vibrating microcantilevers
NASA Astrophysics Data System (ADS)
Adhikari, S.
2017-10-01
Mass sensing using micromechanical cantilever oscillators has been established as a promising approach. The scientific principle underpinning this technique is the shift in the resonance frequency caused by the additional mass in the dynamic system. This approach relies on the fact that the Q-factor of the underlying oscillator is high enough so that it does not significantly affect the resonance frequencies. We consider the case when the Q-factor is low to the extent that the effect of damping is prominent. It is shown that the mass sensing can be achieved using a shift in the damping factor. We prove that the shift in the damping factor is of the same order as that of the resonance frequency. Based on this crucial observation, three new approaches have been proposed, namely, (a) mass sensing using frequency shifts in the complex plane, (b) mass sensing from damped free vibration response in the time domain, and (c) mass sensing from the steady-state response in the frequency domain. Explicit closed-form expressions relating absorbed mass with changes in the measured dynamic properties have been derived. The rationale behind each new method has been explained using non-dimensional graphical illustrations. The new mass sensing approaches using damped dynamic characteristics can expand the current horizon of micromechanical sensing by incorporating a wide range of additional measurements.
Transponder data processing methods and systems
Axline, Robert M.
2003-06-10
This invention is a radar/tag system where pulses from a radar cause a tag (or transponder) to respond to the radar. The radar, along with its conventional pulse transmissions, sends a reference signal to the tag. The tag recovers the reference signal and uses it to shift the center frequency of the received radar pulse to a different frequency. This shift causes the frequencies of the tag response pulses to be disjoint from those of the transmit pulse. In this way, radar clutter can be eliminated from the tag responses. The radar predicts, to within a small Doppler offset, the center frequency of tag response pulses. The radar can create synthetic-aperture-radar-like images and moving-target-indicator-radar-like maps containing the signature of the tag against a background of thermal noise and greatly attenuated radar clutter. The radar can geolocate the tag precisely and accurately (to within better than one meter of error). The tag can encode status and environmental data onto its response pulses, and the radar can receive and decode this information.
Filter-Based Phase Shifts Distort Neuronal Timing Information.
Yael, Dorin; Vecht, Jacob J; Bar-Gad, Izhar
2018-01-01
Filters are widely used for the modulation, typically attenuation, of amplitudes of different frequencies within neurophysiological signals. Filters, however, also induce changes in the phases of different frequencies whose amplitude is unmodulated. These phase shifts cause time lags in the filtered signals, leading to a disruption of the timing information between different frequencies within the same signal and between different signals. The emerging time lags can be either constant in the case of linear phase (LP) filters or vary as a function of the frequency in the more common case of non-LP (NLP) filters. Since filters are used ubiquitously online in the early stages of data acquisition, the vast majority of neurophysiological signals thus suffer from distortion of the timing information even prior to their sampling. This distortion is often exacerbated by further multiple offline filtering stages of the sampled signal. The distortion of timing information may cause misinterpretation of the results and lead to erroneous conclusions. Here we present a variety of typical examples of filter-induced phase distortions and discuss the evaluation and restoration of the timing information underlying the original signal.
Filter-Based Phase Shifts Distort Neuronal Timing Information
Yael, Dorin; Vecht, Jacob J.
2018-01-01
Filters are widely used for the modulation, typically attenuation, of amplitudes of different frequencies within neurophysiological signals. Filters, however, also induce changes in the phases of different frequencies whose amplitude is unmodulated. These phase shifts cause time lags in the filtered signals, leading to a disruption of the timing information between different frequencies within the same signal and between different signals. The emerging time lags can be either constant in the case of linear phase (LP) filters or vary as a function of the frequency in the more common case of non-LP (NLP) filters. Since filters are used ubiquitously online in the early stages of data acquisition, the vast majority of neurophysiological signals thus suffer from distortion of the timing information even prior to their sampling. This distortion is often exacerbated by further multiple offline filtering stages of the sampled signal. The distortion of timing information may cause misinterpretation of the results and lead to erroneous conclusions. Here we present a variety of typical examples of filter-induced phase distortions and discuss the evaluation and restoration of the timing information underlying the original signal. PMID:29766044
Laser Metrology Heterodyne Phase-Locked Loop
NASA Technical Reports Server (NTRS)
Loya, Frank; Halverson, Peter
2009-01-01
A method reduces sensitivity to noise in a signal from a laser heterodyne interferometer. The phase-locked loop (PLL) removes glitches that occur in a zero-crossing detector s output [that can happen if the signal-to-noise ratio (SNR) of the heterodyne signal is low] by the use of an internal oscillator that produces a square-wave signal at a frequency that is inherently close to the heterodyne frequency. It also contains phase-locking circuits that lock the phase of the oscillator to the output of the zero-crossing detector. Because the PLL output is an oscillator signal, it is glitch-free. This enables the ability to make accurate phase measurements in spite of low SNR, creates an immunity to phase error caused by shifts in the heterodyne frequency (i.e. if the target moves causing Doppler shift), and maintains a valid phase even when the signal drops out for brief periods of time, such as when the laser is blocked by a stray object.
Doppler lidar wind measurement with the edge technique
NASA Technical Reports Server (NTRS)
Korb, C. Laurence; Gentry, Bruce M.
1992-01-01
The edge technique is a new and powerful method for measuring small frequency shifts. Range resolved lidar measurements of winds can be made with high accuracy and high vertical resolution using the edge technique to measure the Doppler shift of an atmospheric backscattered signal from a pulsed laser. The edge technique can be used at near-infrared or visible wavelengths using well developed solid state lasers and detectors with various edge filters. In the edge technique, the laser frequency is located on the steep slope of the spectral response function of a high resolution optical filter. Due to the steep slope of the edge, very small frequency shifts cause large changes in measured signal. The frequency of the outgoing laser pulse is determined by measuring its location on the edge of the filter. This is accomplished by sending a small portion of the beam to the edge detection setup where the incoming light is split into two channels - an edge filter and an energy monitor channel. The energy monitor signal is used to normalize the edge filter signal for magnitude. The laser return backscattered from the atmosphere is collected by a telescope and directed through the edge detection setup to determine its frequency (location on the edge) in a similar manner for each range element. The Doppler shift, and thus the wind, is determined from a differential measurement of the frequency of the outgoing laser pulse and the frequency of the laser return backscattered from the atmosphere. We have conducted simulations of the performance of an edge lidar system using an injection seeded pulsed Nd:YAG laser at 1.06 microns. The central fringe of a Fabry-Perot etalon is used as a high resolution edge filter to measure the shift of the aerosol return.
Frequency-chirp rates of harmonics driven by a few-cycle pulse
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murakami, M.; Mauritsson, J.; Gaarde, M.B.
2005-08-15
We present numerical calculations of the time-frequency characteristics of cutoff harmonics generated by few-cycle laser pulses. We find that for driving pulses as short as three optical cycles, the adiabatic prediction for the harmonic chirp rate is very accurate. This negative chirp is so large that the resulting bandwidth causes substantial overlap between neighboring harmonics, and the harmonic phase therefore appears to not vary in time or frequency. By adding a compensating positive chirp to the driving pulse, which reduces the harmonic bandwidth and allows for the appearance of the negative chirp, we can measure the harmonic chirp rates. Wemore » also find that the positive chirp on the driving pulse causes the harmonics to shift down in frequency. We show that this counterintuitive result is caused by the change in the strong field continuum dynamics introduced by the variation of the driving frequency with time.« less
A New Type of Atom Interferometry for Testing Fundamental Physics
NASA Astrophysics Data System (ADS)
Lorek, Dennis; Lämmerzahl, Claus; Wicht, Andreas
We present a new type of atom interferometer (AI) that provides a tool for ultra-high precision tests of fundamental physics. As an example we present how an AI based on highly charged hydrogen-like atoms is affected by gravitational waves (GW). A qualitative description of the quantum interferometric measurement principle is given, the modifications in the atomic Hamiltonian caused by the GW are presented, and the size of the resulting frequency shifts in hydrogen-like atoms is estimated. For a GW amplitude of h = 10-23 the frequency shift is of the order of 110μHz for an AI based on a 91-fold charged uranium ion. A frequency difference of this size can be resolved by current AIs in 1s.
Biosensing in a microelectrofluidic system using optical whispering-gallery mode spectroscopy
Huang, Lei; Guo, Zhixiong
2011-01-01
Label-free detection of biomolecules using an optical whispering-gallery mode sensor in a microelectrofluidic channel is simulated. Negatively charged bovine serum albumin is considered as the model protein analyte. The analyte transport in aqueous solution is controlled by an externally applied electrical field. The finite element method is employed for solving the equations of the charged species transport, the Poisson equation of electric potential, the equations of conservation of momentum and energy, and the Helmholtz equations of electromagnetic waves. The adsorption process of the protein molecules on the microsensor head surface is monitored by the resonance frequency shifts. Frequency shift caused by temperature variation due to Joule heating is analyzed and found to be negligible. The induced shifts behave in a manner similar to Langmuir-like adsorption kinetics; but the time constant increases due to the presence of the external electrical field. A correlation of the frequency shift, the analyte feed concentration in the solution, and the applied voltage gradient is obtained, in which an excellent linear relationship between the frequency shift and the analyte concentration is revealed. The applied voltage gradient enhances significantly the analyte concentration in the vicinity of the sensor surface; thus, the sensor sensitivity which has a power function of the voltage gradient with exponent 2.85 in the controlled voltage range. Simulated detection of extremely low protein concentration to the pico-molar level is carried out. PMID:22662041
NASA Astrophysics Data System (ADS)
Chen, Ruizhu; Zhao, Junwei
2018-02-01
Time–distance helioseismology measures acoustic travel times to infer the structure and flow field of the solar interior; however, both the mean travel times and the travel-time shifts suffer systematic center-to-limb variations, which complicate the interpretation and inversions of the time–distance measurements. In particular, the center-to-limb variation in travel-time shifts (CtoL effect) has a significant impact on the inference of the Sun’s meridional circulation, and needs to be removed from the helioseismic measurements, although the observational properties and the physical cause of the CtoL effect have yet to be investigated. In this study, we measure the CtoL effect in the frequency domain using Doppler-velocity data from the Solar Dynamics Observatory/Helioseismic and Magnetic Imager, and study its properties as a function of disk-centric distance, travel distance, and frequency of acoustic waves. It is found that the CtoL effect has a significant frequency dependence—it reverses sign at a frequency around 5.4 mHz and reaches maximum at around 4.0 mHz before the sign reversal. The tendency of frequency dependence varies with disk-centric distance in a way that both the sign-reversal frequency and the maximum-value frequency decrease closer to the limb. The variation tendency does not change with travel distance, but the variation magnitude is approximately proportional to travel distance. For comparison, the flow-induced travel-time shifts show little frequency dependence. These observational properties provide more clues on the nature of the CtoL effect, and also possibly lead to new ways of effect-removal for a more robust determination of the deep meridional flow.
Frequency Invariability of (Pb,La)(Zr,Ti)O₃ Antiferroelectric Thick-Film Micro-Cantilevers.
An, Kun; Jin, Xuechen; Meng, Jiang; Li, Xiao; Ren, Yifeng
2018-05-13
Micro-electromechanical systems comprising antiferroelectric layers can offer both actuation and transduction to integrated technologies. Micro-cantilevers based on the (Pb 0.97 La 0.02 )(Zr 0.95 Ti 0.05 )O₃ (PLZT) antiferroelectric thick film are fabricated by the micro-nano manufacturing process, to utilize the effect of phase transition induced strain and sharp phase switch of antiferroelectric materials. When micro-cantilevers made of antiferroelectric thick films were driven by sweep voltages, there were two resonant peaks corresponding to the natural frequency shift from 27.8 to 27.0 kHz, before and after phase transition. This is the compensation principle for the PLZT micro-cantilever to tune the natural frequency by the amplitude modulation of driving voltage, rather than of frequency modulation. Considering the natural frequency shift about 0.8 kHz and the frequency tuning ability about 156 Hz/V before the phase transition, this can compensate the frequency shift caused by increasing temperature by tuning only the amplitude of driving voltage, when the ultrasonic micro-transducer made of antiferroelectric thick films works for such a long period. Therefore, antiferroelectric thick films with hetero-structures incorporated into PLZT micro-cantilevers not only require a lower driving voltage (no more than 40 V) than rival bulk piezoelectric ceramics, but also exhibit better performance of frequency invariability, based on the amplitude modulation.
Fernandez, Marta; Espinosa, Hugo G; Thiel, David V; Arrinda, Amaia
2018-01-01
The interaction of body-worn antennas with the human body causes a significant decrease in antenna efficiency and a shift in resonant frequency. A resonant slot in a small conductive box placed on the body has been shown to reduce these effects. The specific absorption rate is less than international health standards for most wearable antennas due to small transmitter power. This paper reports the linear relationship between power absorbed by biological tissues at different locations on the body and radiation efficiency based on numerical modeling (r = 0.99). While the -10 dB bandwidth of the antenna remained constant and equal to 12.5%, the maximum frequency shift occurred when the antenna was close to the elbow (6.61%) and on the thigh (5.86%). The smallest change was found on the torso (4.21%). Participants with body-mass index (BMI) between 17 and 29 kg/m 2 took part in experimental measurements, where the maximum frequency shift was 2.51%. Measurements showed better agreement with simulations on the upper arm. These experimental results demonstrate that the BMI for each individual had little effect on the performance of the antenna. Bioelectromagnetics. 39:25-34, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
FBG wavelength demodulation based on a radio frequency optical true time delay method.
Wang, Jin; Zhu, Wanshan; Ma, Chenyuan; Xu, Tong
2018-06-01
A new fiber Bragg grating (FBG) wavelength shift demodulation method based on optical true time delay microwave phase detection is proposed. We used a microwave photonic link (MPL) to transport a radio frequency (RF) signal over a dispersion compensation fiber (DCF). The wavelength shift of the FBG will cause the time delay change of the optical carrier that propagates in an optical fiber with chromatic dispersion, which will result in the variation of the RF signal phase. A long DCF was adopted to enlarge the RF signal phase variation. An IQ mixer was used to measure the RF phase variation of the RF signal propagating in the MPL, and the wavelength shift of the FBG can be obtained by the measured RF signal phase variation. The experimental results showed that the wavelength shift measurement resolution is 2 pm when the group velocity dispersion of the DCF is 79.5 ps/nm and the frequency of the RF signal is 18 GHz. The demodulation time is as short as 0.1 ms. The measurement resolution can be improved simply by using a higher frequency of the RF signal and a longer DCF or larger chromatic dispersion value of the DCF.
Spontaneous Fluctuations of PO2 in the Rabbit Somatosensory Cortex.
Linsenmeier, Robert A; Aksenov, Daniil P; Faber, Holden M; Makar, Peter; Wyrwicz, Alice M
2016-01-01
In many tissues, PO2 fluctuates spontaneously with amplitudes of a few mmHg. Here we further characterized these oscillations. PO2 recordings were made from the whisker barrel cortex of six rabbits with acutely or chronically placed polarographic electrodes. Measurements were made while rabbits were awake and while anesthetized with isoflurane, during air breathing, and during 100% oxygen inspiration. In awake rabbits, 90% of the power was between 0 and 20 cycles per minute (cpm), not uniformly distributed over this range, but with a peak frequently near 10 cpm. This was much slower than heart or respiratory rhythms and is similar to the frequency content observed in other tissues. During hyperoxia, total power was higher than during air-breathing, and the dominant frequencies tended to shift toward lower values (0-10 cpm). These observations suggest that at least the lower frequency fluctuations represent efforts by the circulation to regulate local PO2. There were no consistent changes in total power during 0.5 or 1.5% isoflurane anesthesia, but the power shifted to lower frequencies. Thus, both hyperoxia and anesthesia cause characteristic, but distinct, changes in spontaneous fluctuations. These PO2 fluctuations may be caused by vasomotion, but other factors cannot be ruled out.
Stimulated Rayleigh-Bragg scattering in two-photon absorbing media
NASA Astrophysics Data System (ADS)
He, Guang S.; Lu, Changgui; Zheng, Qingdong; Prasad, Paras N.; Zerom, Petros; Boyd, Robert W.; Samoc, Marek
2005-06-01
The origin and mechanism of backward stimulated Rayleigh scattering in two-photon absorbing media are studied theoretically and experimentally. This type of stimulated scattering has the unusual features of no frequency shift and low pump threshold requirement compared to all other known stimulated scattering effects. This frequency-unshifted stimulated Rayleigh scattering effect can be well explained by a two-photon-excitation-enhanced Bragg grating reflection model. The reflection of the forward pump beam from this stationary Bragg grating may substantially enhance the backward Rayleigh scattering beam, providing a positive feedback mechanism without causing any frequency shift. A two-counterpropagating-beam-formed grating experiment in a two-photon absorbing dye solution is conducted. The measured dynamic behavior of Bragg grating formation and reflectivity properties are basically consistent with the predictions from the proposed model.
Method and apparatus for analyzing the fill characteristics of a packaging container
Rodriguez, J.G.
1998-10-13
A system is described for analyzing the fill characteristics of a container. A container having a filling material therein is positioned adjacent a sound generator. Sound waves from the generator are applied to the container, causing it to vibrate. A vibration detector is used to determine the amount of container vibration. A preferred vibration detector involves a laser vibrometer which applies a reference laser beam to the vibrating container. The reference beam is reflected off of the container to generate a reflected laser beam. The reflected beam experiences a Doppler frequency shift compared with the reference beam which is caused by container vibration. The Doppler shift of the reflected beam is then compared with standardized Doppler shift data from a control container. Repeated Doppler shift measurements may also be undertaken which are converted into a vibration profile that is compared with a standardized vibration profile from a control container. 4 figs.
Method and apparatus for analyzing the fill characteristics of a packaging container
Rodriguez, Julio G.
1998-01-01
A system for analyzing the fill characteristics of a container. A container having a filling material therein is positioned adjacent a sound generator. Sound waves from the generator are applied to the container, causing it to vibrate. A vibration detector is used to determine the amount of container vibration. A preferred vibration detector involves a laser vibrometer which applies a reference laser beam to the vibrating container. The reference beam is reflected off of the container to generate a reflected laser beam. The reflected beam experiences a Doppler frequency shift compared with the reference beam which is caused by container vibration. The Doppler shift of the reflected beam is then compared with standardized Doppler shift data from a control container. Repeated Doppler shift measurements may also be undertaken which are converted into a vibration profile that is compared with a standardized vibration profile from a control container.
Gravitational redshift space-probe experiment
NASA Technical Reports Server (NTRS)
Vessot, R. F. C.; Levine, M. W.
1979-01-01
A Scout D rocket was launched from Wallops Island, Virginia, carrying an atomic hydrogen maser oscillator system as the payload. The frequency of signals from the oscillator was monitored on the ground at Merritt Island, Florida, by using two hydrogen masers as comparison oscillators. The first-order Doppler shift in the signals was eliminated by a go-return transponder link to the payload, and the resulting data, representing the relativistic shifts, were recovered and recorded. The objective was to measure directly the effect of gravitational potential on the frequency of an atomic hydrogen maser assuming it to be a 'proper' clock. A gravitational effect amounting to some 4.5 parts in 10 to the 10th power was measured with an oscillator having a stability better than 1 part in 10 to the 14th power. Therefore, to make the best possible use of the oscillator, all frequency shifts at the 2 to 5 X 10 to the -15 power level in delta f/f in the system must be accounted for. This includes all the phase variations that can cause such a shift to appear. The experiment, the data available and the manner in which they were processed, and the results are described.
Resonant Frequency Shifts of a Fluid Filled Cavity Caused by a Bubble
NASA Astrophysics Data System (ADS)
Zhang, Hailan; Wang, Xiuming; Chen, Dehua; Che, Chengxuan
2009-03-01
In the previous studies for estimating acoustic wave velocities and attenuations of a rock specimen in a low frequency range using an acoustic resonance spectroscopy method, it was found that bubbles in a fluid filled cavity reduce the resonant frequency of the cavity significantly, which makes the measurement unstable. In this paper, this phenomenon is explained by using a simple model of a spherical fluid filled cavity with a single air bubble. It is pointed out that air bubble effects are caused by the vibration of the bubble coupled with the vibration of the cavity and, therefore, the measurement must be carefully prepared to prevent any air bubbles from entering the cavity.
NASA Astrophysics Data System (ADS)
Shinbo, Kazunari; Ishikawa, Hiroshi; Baba, Akira; Ohdaira, Yasuo; Kato, Keizo; Kaneko, Futao
2012-03-01
We fabricated a hybrid sensor utilizing quartz crystal microbalance (QCM) and surface plasmon resonance (SPR) spectroscopy. We confirmed its effectiveness by observing QCM frequency shifts and SPR wavelength changes for two processes: deposition of various transparent polymer thin films and moisture sorption. For thin-film deposition, the relationship between the QCM frequency and SPR wavelength was found to depend on the refractive index of the film material. For moisture sorption, the direction of SPR wavelength shift depended on the film thickness. This was estimated to be caused by film swelling and decrease in refractive index induced by moisture.
Analysis on optical heterodyne frequency error of full-field heterodyne interferometer
NASA Astrophysics Data System (ADS)
Li, Yang; Zhang, Wenxi; Wu, Zhou; Lv, Xiaoyu; Kong, Xinxin; Guo, Xiaoli
2017-06-01
The full-field heterodyne interferometric measurement technology is beginning better applied by employing low frequency heterodyne acousto-optical modulators instead of complex electro-mechanical scanning devices. The optical element surface could be directly acquired by synchronously detecting the received signal phases of each pixel, because standard matrix detector as CCD and CMOS cameras could be used in heterodyne interferometer. Instead of the traditional four-step phase shifting phase calculating, Fourier spectral analysis method is used for phase extracting which brings lower sensitivity to sources of uncertainty and higher measurement accuracy. In this paper, two types of full-field heterodyne interferometer are described whose advantages and disadvantages are also specified. Heterodyne interferometer has to combine two different frequency beams to produce interference, which brings a variety of optical heterodyne frequency errors. Frequency mixing error and beat frequency error are two different kinds of inescapable heterodyne frequency errors. In this paper, the effects of frequency mixing error to surface measurement are derived. The relationship between the phase extraction accuracy and the errors are calculated. :: The tolerance of the extinction ratio of polarization splitting prism and the signal-to-noise ratio of stray light is given. The error of phase extraction by Fourier analysis that caused by beat frequency shifting is derived and calculated. We also propose an improved phase extraction method based on spectrum correction. An amplitude ratio spectrum correction algorithm with using Hanning window is used to correct the heterodyne signal phase extraction. The simulation results show that this method can effectively suppress the degradation of phase extracting caused by beat frequency error and reduce the measurement uncertainty of full-field heterodyne interferometer.
Schnitzler, Hans-Ulrich; Denzinger, Annette
2011-05-01
Rhythmical modulations in insect echoes caused by the moving wings of fluttering insects are behaviourally relevant information for bats emitting CF-FM signals with a high duty cycle. Transmitter and receiver of the echolocation system in flutter detecting foragers are especially adapted for the processing of flutter information. The adaptations of the transmitter are indicated by a flutter induced increase in duty cycle, and by Doppler shift compensation (DSC) that keeps the carrier frequency of the insect echoes near a reference frequency. An adaptation of the receiver is the auditory fovea on the basilar membrane, a highly expanded frequency representation centred to the reference frequency. The afferent projections from the fovea lead to foveal areas with an overrepresentation of sharply tuned neurons with best frequencies near the reference frequency throughout the entire auditory pathway. These foveal neurons are very sensitive to stimuli with natural and simulated flutter information. The frequency range of the foveal areas with their flutter processing neurons overlaps exactly with the frequency range where DS compensating bats most likely receive echoes from fluttering insects. This tight match indicates that auditory fovea and DSC are adaptations for the detection and evaluation of insects flying in clutter.
Numerical study of bandwidth effect on stimulated Raman backscattering in nonlinear regime
NASA Astrophysics Data System (ADS)
Zhou, H. Y.; Xiao, C. Z.; Zou, D. B.; Li, X. Z.; Yin, Y.; Shao, F. Q.; Zhuo, H. B.
2018-06-01
Nonlinear behaviors of stimulated Raman scattering driven by finite bandwidth pumps are studied by one dimensional particle-in-cell simulations. The broad spectral feature of plasma waves and backscattered light reveals the different coupling and growth mechanisms, which lead to the suppression effect before the deep nonlinear stage. It causes nonperiodic plasma wave packets and reduces packet and etching velocities. Based on the negative frequency shift and electron energy distribution, the long-time evolution of instability can be divided into two stages by the relaxation time. It is a critical time after which the alleviation effects of nonlinear frequency shift and hot electrons are replaced by enhancement. Thus, the broadband pump suppresses instability at early time. However, it aggravates in the deep nonlinear stage by lifting the saturation level due to the coupling of the incident pump with each frequency shifted plasma wave. Our simulation results show that the nonlinear effects are valid in a bandwidth range from 2.25% to 3.0%, and the physics are similar within a nearby parameter space.
Time synchronization of a frequency-hopped MFSK communication system
NASA Technical Reports Server (NTRS)
Simon, M. K.; Polydoros, A.; Huth, G. K.
1981-01-01
In a frequency-hopped (FH) multiple-frequency-shift-keyed (MFSK) communication system, frequency hopping causes the necessary frequency transitions for time synchronization estimation rather than the data sequence as in the conventional (nonfrequency-hopped) system. Making use of this observation, this paper presents a fine synchronization (i.e., time errors of less than a hop duration) technique for estimation of FH timing. The performance degradation due to imperfect FH time synchronization is found in terms of the effect on bit error probability as a function of full-band or partial-band noise jamming levels and of the number of hops used in the FH timing estimate.
Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping
NASA Technical Reports Server (NTRS)
English, T. C.; Jechart, E.; Kwon, T. M.
1978-01-01
Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).
Fonseca, P J; Correia, T
2007-05-01
The effects of temperature on hearing in the cicada Tettigetta josei were studied. The activity of the auditory nerve and the responses of auditory interneurons to stimuli of different frequencies and intensities were recorded at different temperatures ranging from 16 degrees C to 29 degrees C. Firstly, in order to investigate the temperature dependence of hearing processes, we analyzed its effects on auditory tuning, sensitivity, latency and Q(10dB). Increasing temperature led to an upward shift of the characteristic hearing frequency, to an increase in sensitivity and to a decrease in the latency of the auditory response both in the auditory nerve recordings (periphery) and in some interneurons at the metathoracic-abdominal ganglionic complex (MAC). Characteristic frequency shifts were only observed at low frequency (3-8 kHz). No changes were seen in Q(10dB). Different tuning mechanisms underlying frequency selectivity may explain the results observed. Secondly, we investigated the role of the mechanical sensory structures that participate in the transduction process. Laser vibrometry measurements revealed that the vibrations of the tympanum and tympanal apodeme are temperature independent in the biologically relevant range (18-35 degrees C). Since the above mentioned effects of temperature are present in the auditory nerve recordings, the observed shifts in frequency tuning must be performed by mechanisms intrinsic to the receptor cells. Finally, the role of potassium channels in the response of the auditory system was investigated using a specific inhibitor of these channels, tetraethylammonium (TEA). TEA caused shifts on tuning and sensitivity of the summed response of the receptors similar to the effects of temperature. Thus, potassium channels are implicated in the tuning of the receptor cells.
Malakhov, M V; Makarenkova, E A; Mel'nikov, A A; Vikulov, A D
2014-01-01
The influence of breath holding and voluntary hyperventilation on the classic stabilometric parameters and the frequency characteristic of stabilographic signal were studied. We measured the stabilometric parameters on the force platform ("Ritm", Russia) on the healthy volunteers (n = 107) during quiet breath, voluntary hyperventilation (20 seconds) and maximal inspiratory breath holding (20 seconds). Respiratory frequency, respiratory amplitude and ventilation were estimated with strain gauge. We found that antero-posterior and medio-lateral sway amplitude and velocity as well as sway surface at breath-holding and at quiet breathing were the same, so breath holding didn't influence the postural stability. However the spectral parameters shifted to the high frequency range due to alteration of the respiratory muscles contractions during breath-holding versus quiet breath. Voluntary hyperventilation caused significant increase of all stabilographic indices that implied an impairment of postural stability, which was due to the increase of respiration frequency and amplitude. We also found that the spectral indices moved toward the high-frequency range with more pronounced degree of this shift versus breath holding. Besides, amplitudes of spectral peaks also increased. Perhaps such change of spectral indices was due to distortion of proprioceptive information because of increased excitability of nerve fibers during hyperventilation. Maximal inspiration breath holding causes strain of the postural control mechanisms that is reflected as elevation of postural sway frequency with no postural stability changes. Hyperventilation leads to the most prominent strain of balance function and decrease of steadiness that is manifested as increase of center of pressure oscillations amplitude and frequency.
Micro-Optical Distributed Sensors for Aero Propulsion Applications
NASA Astrophysics Data System (ADS)
Arnold, S.; Otugen, V.
2003-01-01
The objective of this research is to develop micro-opto-mechanical system (MOMS)-based sensors for time- and space-resolved measurements of flow properties in aerodynamics applications. The measurement technique we propose uses optical resonances in dielectric micro-spheres that can be excited by radiation tunneling from optical fibers. It exploits the tunneling-induced and morphology-dependent shifts in the resonant frequencies. The shift in the resonant frequency is dependent on the size, shape, and index of refraction of the micro-sphere. A physical change in the environment surrounding a micro-bead can change one or more of these properties of the sphere thereby causing a shift in frequency of resonance. The change of the resonance frequency can be detected with high resolution by scanning a frequency-tunable laser that is coupled into the fiber and observing the transmission spectrum at the output of the fiber. It is expected that, in the future, the measurement concept will lead to a system of distributed micro-sensors providing spatial data resolved in time and space. The present project focuses on the development and demonstration of temperature sensors using the morphology-dependent optical resonances although in the latter part of the work, we will also develop a pressure sensor. During the period covered in this report, the optical and electronic equipment necessary for the experimental work was assembled and the experimental setup was designed for the single sensor temperature measurements. Software was developed for real-time tracking of the optical resonance shifts. Some preliminary experiments were also carried out to detect temperature using a single bead in a water bath.
Micro-optical Distributed Sensors for Aero Propulsion Applications
NASA Technical Reports Server (NTRS)
Arnold, S.; Otugen, V.; Seasholtz, Richard G. (Technical Monitor)
2003-01-01
The objective of this research is to develop micro-opto-mechanical system (MOMS)-based sensors for time- and space-resolved measurements of flow properties in aerodynamics applications. The measurement technique we propose uses optical resonances in dielectric micro-spheres that can be excited by radiation tunneling from optical fibers. It exploits the tunneling-induced and morphology-dependent shifts in the resonant frequencies. The shift in the resonant frequency is dependent on the size, shape, and index of refraction of the micro-sphere. A physical change in the environment surrounding a micro-bead can change one or more of these properties of the sphere thereby causing a shift in frequency of resonance. The change of the resonance frequency can be detected with high resolution by scanning a frequency-tunable laser that is coupled into the fiber and observing the transmission spectrum at the output of the fiber. It is expected that, in the future, the measurement concept will lead to a system of distributed micro-sensors providing spatial data resolved in time and space. The present project focuses on the development and demonstration of temperature sensors using the morphology-dependent optical resonances although in the latter part of the work, we will also develop a pressure sensor. During the period covered in this report, the optical and electronic equipment necessary for the experimental work was assembled and the experimental setup was designed for the single sensor temperature measurements. Software was developed for real-time tracking of the optical resonance shifts. Some preliminary experiments were also carried out to detect temperature using a single bead in a water bath.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yong-Xin; Gao, Fei; Liu, Jia
2014-07-28
Radial uniformity measurements of plasma density were carried out by using a floating double probe in a cylindrical (21 cm in electrode diameter) capacitive discharge reactor driven over a wide range of frequencies (27–220 MHz). At low rf power, a multiple-node structure of standing wave effect was observed at 130 MHz. The secondary density peak caused by the standing wave effect became pronounced and shifts toward the axis as the driving frequency further to increase, indicative of a much more shortened standing-wave wavelength. With increasing rf power, the secondary density peak shift toward the radial edge, namely, the standing-wave wavelength was increased,more » in good qualitative agreement with the previous theory and simulation results. At higher pressures and high frequencies, the rf power was primarily deposited at the periphery of the electrode, due to the fact that the waves were strongly damped as they propagated from the discharge edge into the center.« less
Choi, Bo-Hun; Kwon, Il-Bum
2015-03-09
We propose a distributed residual strain sensor that uses an Al-packaged optical fiber for the first time. The residual strain which causes Brillouin frequency shifts in the optical fiber was measured using Brillouin optical correlation domain analysis with 2 cm spatial resolution. We quantified the Brillouin frequency shifts in the Al-packaged optical fiber by the tensile stress and compared them for a varying number of Al layers in the optical fiber. The Brillouin frequency shift of an optical fiber with one Al layer had a slope of 0.038 MHz/με with respect to tensile stress, which corresponds to 78% of that for an optical fiber without Al layers. After removal of the stress, 87% of the strain remained as residual strain. When different tensile stresses were randomly applied, the strain caused by the highest stress was the only one detected as residual strain. The residual strain was repeatedly measured for a time span of nine months for the purpose of reliability testing, and there was no change in the strain except for a 4% reduction, which is within the error tolerance of the experiment. A composite material plate equipped with our proposed Al-packaged optical fiber sensor was hammered for impact experiment and the residual strain in the plate was successfully detected. We suggest that the Al-packaged optical fiber can be adapted as a distributed strain sensor for smart structures, including aerospace structures.
Sex-specific responses to climate change in plants alter population sex ratio and performance.
Petry, William K; Soule, Judith D; Iler, Amy M; Chicas-Mosier, Ana; Inouye, David W; Miller, Tom E X; Mooney, Kailen A
2016-07-01
Males and females are ecologically distinct in many species, but whether responses to climate change are sex-specific is unknown. We document sex-specific responses to climate change in the plant Valeriana edulis (valerian) over four decades and across its 1800-meter elevation range. Increased elevation was associated with increased water availability and female frequency, likely owing to sex-specific water use efficiency and survival. Recent aridification caused male frequency to move upslope at 175 meters per decade, a rate of trait shift outpacing reported species' range shifts by an order of magnitude. This increase in male frequency reduced pollen limitation and increased seedset. Coupled with previous studies reporting sex-specific arthropod communities, these results underscore the importance of ecological differences between the sexes in mediating biological responses to climate change. Copyright © 2016, American Association for the Advancement of Science.
Analytical theory of the shear Alfvén continuum in the presence of a magnetic island
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, C. R., E-mail: cook@physics.wisc.edu; Hegna, C. C.
2015-04-15
The effect of a magnetic island chain on the shear Alfvén continuum is calculated analytically. Using a WKB approximation of the linearized ideal MHD equations, the island is shown to cause an upshift in the continuum accumulation point frequency. This minimum of the frequency spectrum is shifted from the rational surface to the island separatrix. The structure of the eigenmodes is also presented.
Guan, Liu; Zhao, Jiahao; Yu, Shijie; Li, Peng; You, Zheng
2010-01-01
Micro-cantilever sensors for mass detection using resonance frequency have attracted considerable attention over the last decade in the field of gas sensing. For such a sensing system, an oscillator circuit loop is conventionally used to actuate the micro-cantilever, and trace the frequency shifts. In this paper, gas experiments are introduced to investigate the mechanical resonance frequency shifts of the micro-cantilever within the circuit loop(mechanical resonance frequency, MRF) and resonating frequency shifts of the electric signal in the oscillator circuit (system working frequency, SWF). A silicon beam with a piezoelectric zinc oxide layer is employed in the experiment, and a Self-Actuating-Detecting (SAD) circuit loop is built to drive the micro-cantilever and to follow the frequency shifts. The differences between the two resonating frequencies and their shifts are discussed and analyzed, and a coefficient α related to the two frequency shifts is confirmed. PMID:22163588
Transition to subthreshold activity with the use of phase shifting in a model thalamic network
NASA Astrophysics Data System (ADS)
Thomas, Elizabeth; Grisar, Thierry
1997-05-01
Absence epilepsy involves a state of low frequency synchronous oscillations by the involved neuronal networks. These oscillations may be either above or subthreshold. In this investigation, we studied the methods which could be utilized to transform the threshold activity of neurons in the network to a subthreshold state. A model thalamic network was constructed using the Hodgkin Huxley framework. Subthreshold activity was achieved by the application of stimuli to the network which caused phase shifts in the oscillatory activity of selected neurons in the network. In some instances the stimulus was a periodic pulse train of low frequency to the reticular thalamic neurons of the network while in others, it was a constant hyperpolarizing current applied to the thalamocortical neurons.
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Ren, A.; Zhang, Y. S.
1991-01-01
In the study of the propagation of high power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. In the very high power region, one has to prevent the cutoff reflection caused by the excessive ionization in the background air. A frequency auto-conversion process which can lead to reflectionless propagation of powerful EM pulses in self-generated plasmas is studied. The theory shows that under the proper conditions the carrier frequency, omega, of the pulse will indeed shift upward with the growth of plasma frequency, omega(sub pe). Thus, the plasma during breakdown will always remain transparent to the pulse (i.e., omega greater than omega(sub pe)). A chamber experiment to demonstrate the frequency auto-conversion during the pulse propagation through the self-generated plasma is then conducted in a chamber. The detected frequency shift is compared with the theoretical result calculated y using the measured electron density distribution along the propagation path of the pulse. Good agreement between the theory and the experiment results is obtained.
NASA Astrophysics Data System (ADS)
Hiryu, Shizuko; Katsura, Koji; Lin, Liang-Kong; Riquimaroux, Hiroshi; Watanabe, Yoshiaki
2005-12-01
Biosonar behavior was examined in Taiwanese leaf-nosed bats (Hipposideros terasensis; CF-FM bats) during flight. Echolocation sounds were recorded using a telemetry microphone mounted on the bat's head. Flight speed and three-dimensional trajectory of the bat were reconstructed from images taken with a dual high-speed video camera system. Bats were observed to change the intensity and emission rate of pulses depending on the distance from the landing site. Frequencies of the dominant second harmonic constant frequency component (CF2) of calls estimated from the bats' flight speed agreed strongly with observed values. Taiwanese leaf-nosed bats changed CF2 frequencies depending on flight speed, which caused the CF2 frequencies of the Doppler-shifted echoes to remain constant. Pulse frequencies were also estimated using echoes returning directly ahead of the bat and from its sides for two different flight conditions: landing and U-turn. Bats in flight may periodically alter their attended angles from the front to the side when emitting echolocation pulses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yun; Zhang, Yin
2016-06-08
The mass sensing superiority of a micro/nanomechanical resonator sensor over conventional mass spectrometry has been, or at least, is being firmly established. Because the sensing mechanism of a mechanical resonator sensor is the shifts of resonant frequencies, how to link the shifts of resonant frequencies with the material properties of an analyte formulates an inverse problem. Besides the analyte/adsorbate mass, many other factors such as position and axial force can also cause the shifts of resonant frequencies. The in-situ measurement of the adsorbate position and axial force is extremely difficult if not impossible, especially when an adsorbate is as smallmore » as a molecule or an atom. Extra instruments are also required. In this study, an inverse problem of using three resonant frequencies to determine the mass, position and axial force is formulated and solved. The accuracy of the inverse problem solving method is demonstrated and how the method can be used in the real application of a nanomechanical resonator is also discussed. Solving the inverse problem is helpful to the development and application of mechanical resonator sensor on two things: reducing extra experimental equipments and achieving better mass sensing by considering more factors.« less
Sensing device and method for measuring emission time delay during irradiation of targeted samples
NASA Technical Reports Server (NTRS)
Danielson, J. D. Sheldon (Inventor)
2000-01-01
An apparatus for measuring emission time delay during irradiation of targeted samples by utilizing digital signal processing to determine the emission phase shift caused by the sample is disclosed. The apparatus includes a source of electromagnetic radiation adapted to irradiate a target sample. A mechanism generates first and second digital input signals of known frequencies with a known phase relationship, and a device then converts the first and second digital input signals to analog sinusoidal signals. An element is provided to direct the first input signal to the electromagnetic radiation source to modulate the source by the frequency thereof to irradiate the target sample and generate a target sample emission. A device detects the target sample emission and produces a corresponding first output signal having a phase shift relative to the phase of the first input signal, the phase shift being caused by the irradiation time delay in the sample. A member produces a known phase shift in the second input signal to create a second output signal. A mechanism is then provided for converting each of the first and second analog output signals to digital signals. A mixer receives the first and second digital output signals and compares the signal phase relationship therebetween to produce a signal indicative of the change in phase relationship between the first and second output signals caused by the target sample emission. Finally, a feedback arrangement alters the phase of the second input signal based on the mixer signal to ultimately place the first and second output signals in quadrature. Mechanisms for enhancing this phase comparison and adjustment technique are also disclosed.
NASA Technical Reports Server (NTRS)
Danielson, J. D. Sheldon (Inventor)
2006-01-01
An apparatus for measuring emission time delay during irradiation of targeted samples by utilizing digital signal processing to determine the emission phase shift caused by the sample is disclosed. The apparatus includes a source of electromagnetic radiation adapted to irradiate a target sample. A mechanism generates first and second digital input signals of known frequencies with a known phase relationship, and a device then converts the first and second digital input signals to analog sinusoidal signals. An element is provided to direct the first input signal to the electromagnetic radiation source to modulate the source by the frequency thereof to irradiate the target sample and generate a target sample emission. A device detects the target sample emission and produces a corresponding first output signal having a phase shift relative to the phase of the first input signal, the phase shift being caused by the irradiation time delay in the sample. A member produces a known phase shift in the second input signal to create a second output signal. A mechanism is then provided for converting each of the first and second analog output signals to digital signals. A mixer receives the first and second digital output signals and compares the signal phase relationship therebetween to produce a signal indicative of the change in phase relationship between the first and second output signals caused by the target sample emission. Finally, a feedback arrangement alters the phase of the second input signal based on the mixer signal to ultimately place the first and second output signals in quadrature. Mechanisms for enhancing this phase comparison and adjustment technique are also disclosed.
Parallel-quadrature phase-shifting digital holographic microscopy using polarization beam splitter
Das, Bhargab; Yelleswarapu, Chandra S; Rao, DVGLN
2012-01-01
We present a digital holography microscopy technique based on parallel-quadrature phase-shifting method. Two π/2 phase-shifted holograms are recorded simultaneously using polarization phase-shifting principle, slightly off-axis recording geometry, and two identical CCD sensors. The parallel phase-shifting is realized by combining circularly polarized object beam with a 45° degree polarized reference beam through a polarizing beam splitter. DC term is eliminated by subtracting the two holograms from each other and the object information is reconstructed after selecting the frequency spectrum of the real image. Both amplitude and phase object reconstruction results are presented. Simultaneous recording eliminates phase errors caused by mechanical vibrations and air turbulences. The slightly off-axis recording geometry with phase-shifting allows a much larger dimension of the spatial filter for reconstruction of the object information. This leads to better reconstruction capability than traditional off-axis holography. PMID:23109732
Assessment of Marine Mammal Impact Zones for Use of Military Sonar in the Baltic Sea.
Andersson, Mathias H; Johansson, Torbjörn
2016-01-01
Military sonars are known to have caused cetaceans to strand. Navies in shallow seas use different frequencies and sonar pulses, commonly frequencies between 25 and 100 kHz, compared with most studied NATO sonar systems that have been evaluated for their environmental impact. These frequencies match the frequencies of best hearing in the harbor porpoises and seals resident in the Baltic Sea. This study uses published temporary and permanent threshold shifts, measured behavioral response thresholds, technical specifications of a sonar system, and environmental parameters affecting sound propagation common for the Baltic Sea to estimate the impact zones for harbor porpoises and seals.
Mercury Trapped Ion Frequency Standard for Ultra-Stable Reference Applications
NASA Technical Reports Server (NTRS)
Larsen, Kameron (Inventor); Burt, Eric A. (Inventor); Tjoelker, Robert L. (Inventor); Hamell, Robert L. (Inventor); Tucker, Blake C. (Inventor)
2017-01-01
An atomic clock including an ion trap assembly, a C-field coil positioned for generating a first magnetic field in the interrogation region of the ion trap assembly, a compensation coil positioned for generating a second magnetic field in the interrogation region, wherein the combination of the first and second magnetic fields produces an ion number-dependent second order Zeeman shift (Zeeman shift) in the resonance frequency that is opposite in sign to an ion number-dependent second order Doppler shift (Doppler shift) in the resonance frequency, the C-field coil has a radius selected using data indicating how changes in the radius affect an ion-number-dependent shift in the resonance frequency, such that a difference in magnitude between the Doppler shift and the Zeeman shift is controlled or reduced, and the resonance frequency, including the adjustment by the Zeeman shift, is used to obtain the frequency standard.
Wei, Wenjia; Heinze, Stefanie; Gerstner, Doris G; Walser, Sandra M; Twardella, Dorothee; Reiter, Christina; Weilnhammer, Veronika; Perez-Alvarez, Carmelo; Steffens, Thomas; Herr, Caroline E W
2017-01-01
Studies investigating leisure noise effect on extended high frequency hearing are insufficient and they have inconsistent results. The aim of this study was to investigate if extended high-frequency hearing threshold shift is related to audiometric notch, and if total leisure noise exposure is associated with extended high-frequency hearing threshold shift. A questionnaire of the Ohrkan cohort study was used to collect information on demographics and leisure time activities. Conventional and extended high-frequency audiometry was performed. We did logistic regression between extended high-frequency hearing threshold shift and audiometric notch as well as between total leisure noise exposure and extended high-frequency hearing threshold shift. Potential confounders (sex, school type, and firecrackers) were included. Data from 278 participants (aged 18-23 years, 53.2% female) were analyzed. Associations between hearing threshold shift at 10, 11.2, 12.5, and 14 kHz with audiometric notch were observed with a higher prevalence of threshold shift at the four frequencies, compared to the notch. However, we found no associations between total leisure noise exposure and hearing threshold shift at any extended high frequency. This exploratory analysis suggests that while extended high-frequency hearing threshold shifts are not related to total leisure noise exposure, they are strongly associated with audiometric notch. This leads us to further explore the hypothesis that extended high-frequency threshold shift might be indicative of the appearance of audiometric notch at a later time point, which can be investigated in the future follow-ups of the Ohrkan cohort.
Unusual phonon behavior and ultra-low thermal conductance of monolayer InSe.
Zhou, Hangbo; Cai, Yongqing; Zhang, Gang; Zhang, Yong-Wei
2017-12-21
Monolayer indium selenide (InSe) possesses numerous fascinating properties, such as high electron mobility, quantum Hall effect and anomalous optical response. However, its phonon properties, thermal transport properties and the origin of its structural stability remain unexplored. Using first-principles calculations, we show that the atoms in InSe are highly polarized and such polarization causes strong long-range dipole-dipole interaction (DDI). For acoustic modes, DDI is essential for maintaining its structural stability. For optical modes, DDI causes a significant frequency shift of its out-of-phase vibrations. Surprisingly, we observed that there were two isolated frequency regimes, which were completely separated from other frequency regimes with large frequency gaps. Within each frequency regime, only a single phonon mode exists. We further reveal that InSe possesses the lowest thermal conductance among the known two-dimensional materials due to the low cut-off frequency, low phonon group velocities and the presence of large frequency gaps. These unique behaviors of monolayer InSe can enable the fabrication of novel devices, such as thermoelectric module, single-mode phonon channel and phononic laser.
NASA Astrophysics Data System (ADS)
Kim, Tae-Soo; Lim, Seung-Young; Park, Yong-Keun; Jung, Gunwoo; Song, Jung-Hoon; Cha, Ho-Young; Han, Sang-Woo
2018-06-01
We investigated the distributions and the energy levels of defects in SiO2/AlGaN/GaN highelectron-mobility transistors (HEMTs) by using frequency-dependent ( F- D) capacitance-voltage ( C- V) measurements with resonant optical excitation. A Schottky barrier (SB) and a metal-oxidesemiconductor (MOS) HEMT were prepared to compare the effects of defects in their respective layers. We also investigated the effects of those layers on the threshold voltage ( V th ). A drastic voltage shift in the C- V curve at higher frequencies was caused by the large number of defect levels in the SiO2/GaN interface. A significant shift in V th with additional light illumination was observed due to a charging of the defect states in the SiO2/GaN interface. The voltage shifts were attributed to the detrapping of defect states at the SiO2/GaN interface.
NASA Astrophysics Data System (ADS)
Smetanin, I. V.; Erokhin, A. I.; Baranov, A. N.
2018-07-01
We report the results of the experimental and theoretical study of stimulated temperature scattering in toluene and hexane solutions of Ag-nanoparticles, as well as in pure toluene in the two-photon absorption regime. A four-wave mixing scheme with two counter-propagating pump waves of the same frequency is utilised to demonstrate the lasing effect and the amplification of the backscattered anti-Stokes signal. For the first time, we have measured anti-Stokes spectral shifts which turn out to appreciably exceed the Rayleigh line widths in those liquids. It is shown that the amplification effect is provided predominantly by thermally induced coherent polarisation oscillations, while the dynamic interference temperature grating causes the formation of a self-induced optical cavity inside the interaction region.
Low-frequency noise from large wind turbines.
Møller, Henrik; Pedersen, Christian Sejer
2011-06-01
As wind turbines get larger, worries have emerged that the turbine noise would move down in frequency and that the low-frequency noise would cause annoyance for the neighbors. The noise emission from 48 wind turbines with nominal electric power up to 3.6 MW is analyzed and discussed. The relative amount of low-frequency noise is higher for large turbines (2.3-3.6 MW) than for small turbines (≤ 2 MW), and the difference is statistically significant. The difference can also be expressed as a downward shift of the spectrum of approximately one-third of an octave. A further shift of similar size is suggested for future turbines in the 10-MW range. Due to the air absorption, the higher low-frequency content becomes even more pronounced, when sound pressure levels in relevant neighbor distances are considered. Even when A-weighted levels are considered, a substantial part of the noise is at low frequencies, and for several of the investigated large turbines, the one-third-octave band with the highest level is at or below 250 Hz. It is thus beyond any doubt that the low-frequency part of the spectrum plays an important role in the noise at the neighbors. © 2011 Acoustical Society of America
Wei, Wenjia; Heinze, Stefanie; Gerstner, Doris G.; Walser, Sandra M.; Twardella, Dorothee; Reiter, Christina; Weilnhammer, Veronika; Perez-Alvarez, Carmelo; Steffens, Thomas; Herr, Caroline E.W.
2017-01-01
Background: Studies investigating leisure noise effect on extended high frequency hearing are insufficient and they have inconsistent results. The aim of this study was to investigate if extended high-frequency hearing threshold shift is related to audiometric notch, and if total leisure noise exposure is associated with extended high-frequency hearing threshold shift. Materials and Methods: A questionnaire of the Ohrkan cohort study was used to collect information on demographics and leisure time activities. Conventional and extended high-frequency audiometry was performed. We did logistic regression between extended high-frequency hearing threshold shift and audiometric notch as well as between total leisure noise exposure and extended high-frequency hearing threshold shift. Potential confounders (sex, school type, and firecrackers) were included. Results: Data from 278 participants (aged 18–23 years, 53.2% female) were analyzed. Associations between hearing threshold shift at 10, 11.2, 12.5, and 14 kHz with audiometric notch were observed with a higher prevalence of threshold shift at the four frequencies, compared to the notch. However, we found no associations between total leisure noise exposure and hearing threshold shift at any extended high frequency. Conclusion: This exploratory analysis suggests that while extended high-frequency hearing threshold shifts are not related to total leisure noise exposure, they are strongly associated with audiometric notch. This leads us to further explore the hypothesis that extended high-frequency threshold shift might be indicative of the appearance of audiometric notch at a later time point, which can be investigated in the future follow-ups of the Ohrkan cohort. PMID:29319010
Modelling of rotation-induced frequency shifts in whispering gallery modes
NASA Astrophysics Data System (ADS)
Venediktov, V. Yu; Kukaev, A. S.; Filatov, Yu V.; Shalymov, E. V.
2018-02-01
We study the angular velocity sensors based on whispering gallery mode resonators. Rotation of such resonators gives rise to various effects that can cause a spectral shift of their modes. Optical methods allow this shift to be determined with high precision, which can be used practically to measure the angular velocity in inertial orientation and navigation systems. The basic principles of constructing the angular velocity sensors utilising these effects are considered, their advantages and drawbacks are indicated. We also study the interrelation between the effects and the possibility of their mutual influence on each other. Based on the analytical studies of the effects, we consider the possibility of their combined application for angular velocity measurements.
Effects of hydrogen atom spin exchange collisions on atomic hydrogen maser oscillation frequency
NASA Technical Reports Server (NTRS)
Crampton, S. B.
1979-01-01
Frequency shifts due to collisions between hydrogen atoms in an atomic hydrogen maser frequency standard are studied. Investigations of frequency shifts proportional to the spin exchange frequency shift cross section and those proportional to the duration of exchange collisions are discussed. The feasibility of operating a hydrogen frequency standard at liquid helium temperatures is examined.
Estimating forest species composition using a multi-sensor approach
P.T. Wolter
2009-01-01
The magnitude, duration, and frequency of forest disturbance caused by the spruce budworm and forest tent caterpillar has increased over the last century due to a shift in forest species composition linked to historical fire suppression, forest management, and pesticide application that has fostered the increase in dominance of host tree species. Modeling approaches...
Spatiotemporal variability of wildland fuels in US Northern Rocky Mountain forests
Robert E. Keane
2016-01-01
Fire regimes are ultimately controlled by wildland fuel dynamics over space and time; spatial distributions of fuel influence the size, spread, and intensity of individual fires, while the temporal distribution of fuel deposition influences fire's frequency and controls fire size. These "shifting fuel mosaics" are both a cause and a consequence...
Rotstein, Horacio G
2014-01-01
We investigate the dynamic mechanisms of generation of subthreshold and phase resonance in two-dimensional linear and linearized biophysical (conductance-based) models, and we extend our analysis to account for the effect of simple, but not necessarily weak, types of nonlinearities. Subthreshold resonance refers to the ability of neurons to exhibit a peak in their voltage amplitude response to oscillatory input currents at a preferred non-zero (resonant) frequency. Phase-resonance refers to the ability of neurons to exhibit a zero-phase (or zero-phase-shift) response to oscillatory input currents at a non-zero (phase-resonant) frequency. We adapt the classical phase-plane analysis approach to account for the dynamic effects of oscillatory inputs and develop a tool, the envelope-plane diagrams, that captures the role that conductances and time scales play in amplifying the voltage response at the resonant frequency band as compared to smaller and larger frequencies. We use envelope-plane diagrams in our analysis. We explain why the resonance phenomena do not necessarily arise from the presence of imaginary eigenvalues at rest, but rather they emerge from the interplay of the intrinsic and input time scales. We further explain why an increase in the time-scale separation causes an amplification of the voltage response in addition to shifting the resonant and phase-resonant frequencies. This is of fundamental importance for neural models since neurons typically exhibit a strong separation of time scales. We extend this approach to explain the effects of nonlinearities on both resonance and phase-resonance. We demonstrate that nonlinearities in the voltage equation cause amplifications of the voltage response and shifts in the resonant and phase-resonant frequencies that are not predicted by the corresponding linearized model. The differences between the nonlinear response and the linear prediction increase with increasing levels of the time scale separation between the voltage and the gating variable, and they almost disappear when both equations evolve at comparable rates. In contrast, voltage responses are almost insensitive to nonlinearities located in the gating variable equation. The method we develop provides a framework for the investigation of the preferred frequency responses in three-dimensional and nonlinear neuronal models as well as simple models of coupled neurons.
NASA Astrophysics Data System (ADS)
Kolek, Przemysław; Leśniewski, Sebastian; Andrzejak, Marcin; Góra, Maciej; Cias, Pawel; Weģrzynowicz, Adam; Najbar, Jan
2010-12-01
Laser induced fluorescence (LIF) excitation spectrum for the S 0 → S 1 transition of anthranilic acid molecules deuterated in the substituent groups (COOD, ND 2) was investigated. Analysis of the LIF spectrum allowed for the assignment of the six most prominent fundamental in-plane modes of frequencies up to ca. 850 cm. The experimental results show good correlation with the frequency changes upon deuteration computed with CIS (CI-Singles) and TD-DFT for the S 1 state. Deuteration induced red-shifts of the identified fundamental bands are used for examination of the alternative assignments proposed in earlier studies. Potential energy distributions (PED) and overlaps of the in-plane normal modes with frequencies below 850 cm indicate that the correspondence of the respective vibrations of the deuterated and non-deuterated molecule is very good. A blue-shift of the 00 transition due to the isotopic substitution, is equal to 47 cm. This relatively large value is caused primarily by a significant decrease of the N-H stretching frequency associated with the increase of strength of the intramolecular hydrogen bond upon the electronic excitation. The deuteration shift of the 00 band was interpreted in terms of the differences of the zero point energy (ZPE) between the S 0 and S 1 electronic states, computed with DFT and TD-DFT methods, respectively.
Li, Wanbo; Dive, Marc; Tamma, Nico; Michaux, Charles; Druet, Tom; Huijbers, Ivo J.; Isacke, Clare M.; Coppieters, Wouter; Georges, Michel; Charlier, Carole
2009-01-01
We herein describe the positional identification of a 2-bp deletion in the open reading frame of the MRC2 receptor causing the recessive Crooked Tail Syndrome in cattle. The resulting frame-shift reveals a premature stop codon that causes nonsense-mediated decay of the mutant messenger RNA, and the virtual absence of functional Endo180 protein in affected animals. Cases exhibit skeletal anomalies thought to result from impaired extracellular matrix remodeling during ossification, and as of yet unexplained muscular symptoms. We demonstrate that carrier status is very significantly associated with desired characteristics in the general population, including enhanced muscular development, and that the resulting heterozygote advantage caused a selective sweep which explains the unexpectedly high frequency (25%) of carriers in the Belgian Blue Cattle Breed. PMID:19779552
A source mechanism producing HF-induced plasma lines (HFPLS) with up-shifted frequencies
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Lee, M. C.
1992-01-01
Attention is given to a nonlinear scattering process analyzed as a source mechanism producing the frequency up-shifted HFPLs observed in the Arecibo ionospheric heating experiments. A physical picture is offered to explain how Langmuir waves with frequencies greater than the HF heater wave frequency can be produced in the heating experiments and be detected by incoherent radars as frequency up-shifted HFPLs. Since the considered scattering process occurs in a region near the reflection height, it explains why the frequency up-shifted HFPLs should originate from the altitude near the reflection height as observed. The theory also shows that the amount of frequency up-shift is inversely proportional to the frequency of the HF heater and increases linearly with the electron temperature. The quantitative analysis of the theory shows a good agreement with the experimental results.
Apparatus and method for monitoring the presence of a conductive media
DuVall, Bruce W.; Valentine, James W.; Morey, Kenneth O.
1979-01-01
An inductive level sensor has inductively coupled primary and secondary windings. Circuitry drives the primary with an AC signal of constant current magnitude and selected frequency f to induce in the secondary, a voltage signal V of magnitude .vertline.V.vertline., frequency f and phase difference .phi. from the driving signal. Circuitry operates to generate a voltage output signal proportional to .vertline.V.vertline. cos (.phi.-.theta.), where .theta. is a selectively set phase shift factor. By properly and selectively adjusting the frequency f and phase shift factor .theta., an output signal .vertline.V.vertline. cos (.phi.-.theta.) can be provided which self-compensates for changes in mutual inductance caused by operating temperature variations so that an output signal is produced which is substantially linearly proportional to changes in the level of a pool of liquid metal being monitored. Disclosed also is calibration circuitry and circuitry for converting the voltage signal .vertline.V.vertline. cos (.phi.-.theta.) into a current signal.
Repetitive Interrogation of 2-Level Quantum Systems
NASA Technical Reports Server (NTRS)
Prestage, John D.; Chung, Sang K.
2010-01-01
Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.
Linear and nonlinear mechanical properties of a series of epoxy resins
NASA Technical Reports Server (NTRS)
Curliss, D. B.; Caruthers, J. M.
1987-01-01
The linear viscoelastic properties have been measured for a series of bisphenol-A-based epoxy resins cured with the diamine DDS. The linear viscoelastic master curves were constructed via time-temperature superposition of frequency dependent G-prime and G-double-prime isotherms. The G-double-prime master curves exhibited two sub-Tg transitions. Superposition of isotherms in the glass-to-rubber transition (i.e., alpha) and the beta transition at -60 C was achieved by simple horizontal shifts in the log frequency axis; however, in the region between alpha and beta, superposition could not be effected by simple horizontal shifts along the log frequency axis. The different temperature dependency of the alpha and beta relaxation mechanisms causes a complex response of G-double-prime in the so called alpha-prime region. A novel numerical procedure has been developed to extract the complete relaxation spectra and its temperature dependence from the G-prime and G-double-prime isothermal data in the alpha-prime region.
Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum
NASA Technical Reports Server (NTRS)
Lee, Seungwon
2012-01-01
This software processes the flyby spectra of the Chirp Transform Spectrometer (CTS) of the Microwave Instrument for Rosetta Orbiter (MIRO). The tool corrects the effect of Doppler shift and local-oscillator (LO) frequency shift during the flyby mode of MIRO operations. The frequency correction for CTS flyby spectra is performed and is integrated with multiple spectra into a high signal-to-noise averaged spectrum at the rest-frame RF frequency. This innovation also generates the 8 molecular line spectra by dividing continuous 4,096-channel CTS spectra. The 8 line spectra can then be readily used for scientific investigations. A spectral line that is at its rest frequency in the frame of the Earth or an asteroid will be observed with a time-varying Doppler shift as seen by MIRO. The frequency shift is toward the higher RF frequencies on approach, and toward lower RF frequencies on departure. The magnitude of the shift depends on the flyby velocity. The result of time-varying Doppler shift is that of an observed spectral line will be seen to move from channel to channel in the CTS spectrometer. The direction (higher or lower frequency) in the spectrometer depends on the spectral line frequency under consideration. In order to analyze the flyby spectra, two steps are required. First, individual spectra must be corrected for the Doppler shift so that individual spectra can be superimposed at the same rest frequency for integration purposes. Second, a correction needs to be applied to the CTS spectra to account for the LO frequency shifts that are applied to asteroid mode.
NASA Astrophysics Data System (ADS)
Djezzar, Boualem; Tahi, Hakim; Benabdelmoumene, Abdelmadjid; Chenouf, Amel; Kribes, Youcef
2012-11-01
In this paper, we present a new method, named on the fly oxide trap (OTFOT), to extract the bias temperature instability (BTI) in MOS transistors. The OTFOT method is based on charge pumping technique (CP) at low and high frequencies. We emphasize on the theoretical-based concept, giving a clear insight on the easy-use of the OTFOT methodology and demonstrating its viability to characterize the negative BTI (NBTI). Using alternatively high and low frequencies, OTFOT method separates the interface-traps (ΔNit) and border-trap (ΔNbt) (switching oxide-trap) densities independently and also their contributions to the threshold voltage shift (ΔVth), without needing additional methods. The experimental results, from two experimental scenarios, showing the extraction of NBTI-induced shifts caused by interface- and oxide-trap increases are also presented. In the first scenario, all stresses are performed on the same transistor. It exhibits an artifact value of exponent n. In the second scenario, each voltage stress is applied only on one transistor. Its results show an average n of 0.16, 0.05, and 0.11 for NBTI-induced ΔNit, ΔNbt, ΔVth, respectively. Therefore, OTFOT method can contribute to further understand the behavior of the NBTI degradation, especially through the threshold voltage shift components such as ΔVit and ΔVot caused by interface-trap and border-trap, respectively.
Response mechanism for surface acoustic wave gas sensors based on surface-adsorption.
Liu, Jiansheng; Lu, Yanyan
2014-04-16
A theoretical model is established to describe the response mechanism of surface acoustic wave (SAW) gas sensors based on physical adsorption on the detector surface. Wohljent's method is utilized to describe the relationship of sensor output (frequency shift of SAW oscillator) and the mass loaded on the detector surface. The Brunauer-Emmett-Teller (BET) formula and its improved form are introduced to depict the adsorption behavior of gas on the detector surface. By combining the two methods, we obtain a theoretical model for the response mechanism of SAW gas sensors. By using a commercial SAW gas chromatography (GC) analyzer, an experiment is performed to measure the frequency shifts caused by different concentration of dimethyl methylphosphonate (DMMP). The parameters in the model are given by fitting the experimental results and the theoretical curve agrees well with the experimental data.
Magnetic Compensation for Second-Order Doppler Shift in LITS
NASA Technical Reports Server (NTRS)
Burt, Eric; Tjoelker, Robert
2008-01-01
The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.
Binaural beats and frequency-coding.
Fritze, W; Köhler, W
1986-01-01
Binaural beats were studied before and during a situation of temporary threshold shift, and no frequency shift could be found. In contrast, subjective binaural frequency comparison revealed a distinct shift. These findings demonstrate the two known modes of perception.
Shift work is associated with reduced heart rate variability among men but not women.
Hulsegge, Gerben; Gupta, Nidhi; Proper, Karin I; van Lobenstein, Natasja; IJzelenberg, Wilhelmina; Hallman, David M; Holtermann, Andreas; van der Beek, Allard J
2018-05-01
Imbalance in the autonomic nervous system due to a disrupted circadian rhythm may be a cause of shift work-related cardiovascular diseases. We aimed to determine the association between shift work and cardiac autonomic activity in blue-collar workers. The study included 665 blue-collar workers aged 18-68 years in different occupations from two Danish cohort studies. Time and frequency domain parameters of heart rate variability (HRV) were measured during sleep using the Actiheart monitor, and used as markers of cardiac autonomic function. Multiple linear regression analyses were used to investigate differences in HRV between day and shift workers. Shift workers had no significantly different HRV parameters than day workers, except for a lower VLF (B: 0.21; 95% CI: -0.36-0.05). The lower VLF was only present among non-night shift workers (p < 0.05) and not among night shift workers (p > 0.05). Results differed significantly by gender (p for interaction < 0.10): among men, shift work was negatively associated with RMSSD (B: -7.83; 95% CI: -14.28-1.38), SDNN (B: -7.0; 95% CI: -12.27-1.78), VLF (B: -0.27; 95% CI: -0.46-0.09) and Total Power (B: -0.61; 95% CI: -1.20-0.03), while among women, shift work was only associated with the LF/HF ratio (B: -0.29; 95% CI: -0.54-0.03). Shift work was particularly associated with lower HRV during sleep among men. This indicates that shift work causes imbalance in the autonomic nervous system among men, which might increase their risk of cardiovascular diseases. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Peter P. Wolter; Phillip A. Townsend
2011-01-01
The magnitude, duration, and frequency of forest disturbance caused by the spruce budworm and forest tent caterpillar in northern Minnesota and neighboring Ontario, Canada have increased over the last century due to a shift in forest species composition linked to historical fire suppression, forest management, and pesticide application that has fostered increased...
Edge technique for measurement of laser frequency shifts including the Doppler shift
NASA Technical Reports Server (NTRS)
Korb, Larry (Inventor)
1991-01-01
A method is disclosed for determining the frequency shift in a laser system by transmitting an outgoing laser beam. An incoming laser beam having a frequency shift is received. A first signal is acquired by transmitting a portion of the incoming laser beam to an energy monitor detector. A second signal is acquired by transmitting a portion of the incoming laser beam through an edge filter to an edge detector, which derives a first normalized signal which is proportional to the transmission of the edge filter at the frequency of the incoming laser beam. A second normalized signal is acquired which is proportional to the transmission of the edge filter at the frequency of the outgoing laser beam. The frequency shift is determined by processing the first and second normalized signals.
Frequency shift of the Bragg and Non-Bragg backscattering from periodic water wave
NASA Astrophysics Data System (ADS)
Wen, Biyang; Li, Ke
2016-08-01
Doppler effect is used to measure the relative speed of a moving target with respect to the radar, and is also used to interpret the frequency shift of the backscattering from the ocean wave according to the water-wave phase velocity. The widely known relationship between the Doppler shift and the water-wave phase velocity was deduced from the scattering measurements data collected from actual sea surface, and has not been verified under man-made conditions. Here we show that this ob- served frequency shift of the scattering data from the Bragg and Non-Bragg water wave is not the Doppler shift corresponding to the water-wave phase velocity as commonly believed, but is the water-wave frequency and its integral multiple frequency. The power spectrum of the backscatter from the periodic water wave consists of serials discrete peaks, which is equally spaced by water wave frequency. Only when the water-wave length is the integer multiples of the Bragg wave, and the radar range resolution is infinite, does the frequency shift of the backscattering mathematically equal the Doppler shift according to the water-wave phase velocity.
NASA Technical Reports Server (NTRS)
Croell, Arne; Dold, P.; Kaiser, Th.; Szofran, Frank; Benz, K. W.
1999-01-01
Hear and mass transfer in float-zone processing are strongly influenced by convective flows in the zone. They are caused by buoyancy convection, thermocapillary (Marangoni) convection, or artificial sources such as rotation and radio frequency heating. Flows in conducting melts can be controlled by the use of magnetic fields, either by damping fluid motion with static fields or by generating a def@ned flow with rotating fields. The possibilities of using static and rotating magnetic fields in silicon floating-zone growth have been investigated by experiments in axial static fields up to ST and in transverse rotating magnetic fields up to 7.S mT. Static fields of a few 100 MT already suppress most striations but are detrimental to the radial segregation by introducing a coring effect. A complete suppression of dopant striations caused by time-dependent thermocapillary convection and a reduction of the coring to insignificant values, combined with a shift of the axial segregation profile towards a more diffusion-limited case, is possible with static fields ? 1T. However, under certain conditions the use of high axial magnetic fields can lead to the appearance of a new type of pronounced dopant striations, caused by thermoelec:romagnetic convection. The use of a transverse rotating magnetic field influences the microscopic segregation at quite low inductions, of the order of a few mT. The field shifts time-dependent flows and the resulting striation patterns from a broad range of low frequencies at high amplitudes to a few high frequencies at low amplitudes
NASA Technical Reports Server (NTRS)
Croll, A.; Dold, P.; Kaiser, Th.; Szofran, F. R.; Benz, K. W.
1999-01-01
Heat and mass transfer in float-zone processing are strongly influenced by convective flows in the zone. They are caused by buoyancy convection, thermocapillary (Marangoni) convection, or artificial sources such as rotation and radio-frequency heating. Flows in conducting melts can be controlled by the use of magnetic fields, either by damping fluid motion with static fields or by generating a defined flow with rotating fields. The possibilities of using static and rotating magnetic fields in silicon floating-zone growth have been investigated by experiments in axial static fields up to 5 T and in transverse rotating magnetic fields up to 7.5 mT. Static fields of a few 100 mT already suppress most striations but are detrimental to the radial segregation by introducing a coring effect. A complete suppression of dopant striations caused by time-dependent thermocapillary convection and a reduction of the coring to insignificant values, combined with a shift of the axial segregation profile toward a more diffusion-limited case, is possible with static fields greater than or equal to 1 T. However, under certain conditions the use of high axial magnetic fields can lead to the appearance of a new type of pronounced dopant striations, caused by thermoelectromagnetic convection. The use of a transverse rotating magnetic field influences the microscopic segregation at quite low inductions, of the order of a few millitesla. The field shifts time- dependent flows and the resulting striation patterns from a broad range of low frequencies at high amplitudes to a few high frequencies at low amplitudes.
Effects of frequency shifts and visual gender information on vowel category judgments
NASA Astrophysics Data System (ADS)
Glidden, Catherine; Assmann, Peter F.
2003-10-01
Visual morphing techniques were used together with a high-quality vocoder to study the audiovisual contribution of talker gender to the identification of frequency-shifted vowels. A nine-step continuum ranging from ``bit'' to ``bet'' was constructed from natural recorded syllables spoken by an adult female talker. Upward and downward frequency shifts in spectral envelope (scale factors of 0.85 and 1.0) were applied in combination with shifts in fundamental frequency, F0 (scale factors of 0.5 and 1.0). Downward frequency shifts generally resulted in malelike voices whereas upward shifts were perceived as femalelike. Two separate nine-step visual continua from ``bit'' to ``bet'' were also constructed, one from a male face and the other a female face, each producing the end-point words. Each step along the two visual continua was paired with the corresponding step on the acoustic continuum, creating natural audiovisual utterances. Category boundary shifts were found for both acoustic cues (F0 and formant frequency shifts) and visual cues (visual gender). The visual gender effect was larger when acoustic and visual information were matched appropriately. These results suggest that visual information provided by the speech signal plays an important supplemental role in talker normalization.
Frequency shifts of an electric-dipole resonance near a conducting surface
NASA Technical Reports Server (NTRS)
Holland, W. R.; Hall, D. G.
1984-01-01
The resonance frequency of an electric dipole placed near a conducting surface is shifted by the dipole-surface interaction. The observation and measurement of these shifts at optical frequencies is reported for an experimental system that consists of a metal-island film spaced a distance d from a continuous Ag film. The dependence of the shift in the frequency of the island resonance on d shows good agreement with that predicted by a classical theory of the dipole-surface interaction.
Sun, Xiaojing; Wang, Yihua; Ajtai, Katalin
2017-01-01
Myosin motors in cardiac ventriculum convert ATP free energy to the work of moving blood volume under pressure. The actin bound motor cyclically rotates its lever-arm/light-chain complex linking motor generated torque to the myosin filament backbone and translating actin against resisting force. Previous research showed that the unloaded in vitro motor is described with high precision by single molecule mechanical characteristics including unitary step-sizes of approximately 3, 5, and 8 nm and their relative step-frequencies of approximately 13, 50, and 37%. The 3 and 8 nm unitary step-sizes are dependent on myosin essential light chain (ELC) N-terminus actin binding. Step-size and step-frequency quantitation specifies in vitro motor function including duty-ratio, power, and strain sensitivity metrics. In vivo, motors integrated into the muscle sarcomere form the more complex and hierarchically functioning muscle machine. The goal of the research reported here is to measure single myosin step-size and step-frequency in vivo to assess how tissue integration impacts motor function. A photoactivatable GFP tags the ventriculum myosin lever-arm/light-chain complex in the beating heart of a live zebrafish embryo. Detected single GFP emission reports time-resolved myosin lever-arm orientation interpreted as step-size and step-frequency providing single myosin mechanical characteristics over the active cycle. Following step-frequency of cardiac ventriculum myosin transitioning from low to high force in relaxed to auxotonic to isometric contraction phases indicates that the imposition of resisting force during contraction causes the motor to down-shift to the 3 nm step-size accounting for >80% of all the steps in the near-isometric phase. At peak force, the ATP initiated actomyosin dissociation is the predominant strain inhibited transition in the native myosin contraction cycle. The proposed model for motor down-shifting and strain sensing involves ELC N-terminus actin binding. Overall, the approach is a unique bottom-up single molecule mechanical characterization of a hierarchically functional native muscle myosin. PMID:28423017
Properties of seismic absorption induced reflections
NASA Astrophysics Data System (ADS)
Zhao, Haixia; Gao, Jinghuai; Peng, Jigen
2018-05-01
Seismic reflections at an interface are often regarded as the variation of the acoustic impedance (product of seismic velocity and density) in a medium. In fact, they can also be generated due to the difference in absorption of the seismic energy. In this paper, we investigate the properties of such reflections. Based on the diffusive-viscous wave equation and elastic diffusive-viscous wave equation, we investigate the dependency of the reflection coefficients on frequency, and their variations with incident angles. Numerical results at a boundary due to absorption contrasts are compared with those resulted from acoustic impedance variation. It is found that, the reflection coefficients resulted from absorption depend significantly on the frequency especially at lower frequencies, but vary very slowly at small incident angles. At the higher frequencies, the reflection coefficients of diffusive-viscous wave and elastic diffusive-viscous wave are close to those of acoustic and elastic cases, respectively. On the other hand, the reflections caused by acoustic impedance variation are independent of frequency but vary distinctly with incident angles before the critical angle. We also investigate the difference between the seismograms generated in the two different media. The numerical results show that the amplitudes of these reflected waves are attenuated and their phases are shifted. However, the reflections obtained by acoustic impedance contrast, show no significant amplitude attenuation and phase shift.
Normal mode and experimental analysis of TNT Raman spectrum
NASA Astrophysics Data System (ADS)
Liu, Yuemin; Perkins, Richard; Liu, Yucheng; Tzeng, Nianfeng
2017-04-01
In this study, a Raman spectrum of TNT was characterized through experiments and simulated using 22 hybrid density functional theory (DFT) methods. Among the different hybrid DFT methods, it was found that the most accurate simulation results of the Raman shift frequency were calculated by the O3LYP method. However, the deviations of the calculated Raman frequencies from the experimental value showed no dependency on the abilities of the DFT methods in recovering the correlation energy. The accuracies of the DFT methods in predicting the Raman bands are probably determined by the numerical grid and convergence criteria for optimizations of each DFT method. It was also decided that the prominent Raman shift 1362 cm-1 is mainly caused by symmetric stretching of the 4-nitro groups. Findings of this study can facilitate futuristic development of more effective surface enhanced Raman spectroscopy/scattering (SERS) substrates for explosive characterization and detection.
Response Mechanism for Surface Acoustic Wave Gas Sensors Based on Surface-Adsorption
Liu, Jiansheng; Lu, Yanyan
2014-01-01
A theoretical model is established to describe the response mechanism of surface acoustic wave (SAW) gas sensors based on physical adsorption on the detector surface. Wohljent's method is utilized to describe the relationship of sensor output (frequency shift of SAW oscillator) and the mass loaded on the detector surface. The Brunauer-Emmett-Teller (BET) formula and its improved form are introduced to depict the adsorption behavior of gas on the detector surface. By combining the two methods, we obtain a theoretical model for the response mechanism of SAW gas sensors. By using a commercial SAW gas chromatography (GC) analyzer, an experiment is performed to measure the frequency shifts caused by different concentration of dimethyl methylphosphonate (DMMP). The parameters in the model are given by fitting the experimental results and the theoretical curve agrees well with the experimental data. PMID:24743157
NASA Astrophysics Data System (ADS)
Wang, Hongxiang; Wang, Qi; Bai, Lin; Ji, Yuefeng
2018-01-01
A scheme is proposed to realize the all-optical phase regeneration of four-channel quadrature phase shift keying (QPSK) signal based on phase-sensitive amplification. By utilizing conjugate pump and common pump in a highly nonlinear optical fiber, degenerate four-wave mixing process is observed, and QPSK signals are regenerated. The number of waves is reduced to decrease the cross talk caused by undesired nonlinear interaction during the coherent superposition process. In addition, to avoid the effect of overlapping frequency, frequency spans between pumps and signals are set to be nonintegral multiples. Optical signal-to-noise ratio improvement is validated by bit error rate measurements. Compared with single-channel regeneration, multichannel regeneration brings 0.4-dB OSNR penalty when the value of BER is 10-3, which shows the cross talk in regeneration process is negligible.
Optical rotation based chirality detection of enantiomers via weak measurement in frequency domain
NASA Astrophysics Data System (ADS)
Li, Dongmei; Guan, Tian; Liu, Fang; Yang, Anping; He, Yonghong; He, Qinghua; Shen, Zhiyuan; Xin, Meiguo
2018-05-01
A transmission optical rotation detection scheme based on a weak measurement was proposed for the chirality detection of enantiomers. In this transmission weak measurement system in the frequency domain, the optical activity of the chiral liquid sample was estimated with the central wavelength shift, by modifying the preselected polarization state with the optical rotation (OR). The central wavelength shift of output spectra is sensitive to the OR angle but immune to the interference of the refractive index change caused by measuring circumstances. Two isomers of chiral amino acid acquired opposite responses with this system, and a resolution of 2.17 × 10-9 mol/ml for Proline detection could be obtained. Such a resolution is about 2 orders of magnitude higher than that of common methods, which shows a high sensitivity. This proposed weak measurement scenario suggested an approach to polarimetry and provided a way to accurately assess molecular chirality.
Numerical investigation of frequency spectrum in the Hasegawa-Wakatani model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Juhyung; Terry, P. W.
2013-10-15
The wavenumber-frequency spectrum of the two-dimensional Hasegawa-Wakatani model is investigated in the hydrodynamic, intermediate, and adiabatic regimes. A nonlinear frequency and a line width related to energy transfer properties provide a measure of the average frequency and spectral broadening, respectively. In the adiabatic regime, narrow spectra, typical of wave turbulence, are observed with a nonlinear frequency shift in the electron drift direction. In the hydrodynamic regime, broad spectra with almost zero nonlinear frequencies are observed. Nonlinear frequency shifts are shown to be related to nonlinear energy transfer by vorticity advection through the high frequency region of the spectrum. In themore » intermediate regime, the nonlinear frequency shift for density fluctuations is observed to be weaker than that of electrostatic potential fluctuations. The weaker frequency shift of the density fluctuations is due to nonlinear density advection, which favors energy transfer in the low frequency range. Both the nonlinear frequency and the spectral width increase with poloidal wavenumber k{sub y}. In addition, in the adiabatic regime where the nonlinear interactions manifest themselves in the nonlinear frequency shift, the cross-phase between the density and potential fluctuations is observed to match a linear relation, but only if the linear response of the linearly stable eigenmode branch is included. Implications of these numerical observations are discussed.« less
Afforestation, restoration and regeneration -- Not all trees are created equal
Shaneka Lawson; Charles H. Michler
2014-01-01
Undulations in weather patterns have caused climate shifts of increased frequency and duration around the world. The need for additional research and model data on this pressing problem has resulted in a plethora of research groups examining a particular tree species or biome for negative effects of climate change. This review aims to (1) collect and merge recent...
NASA Astrophysics Data System (ADS)
Santos, Ângela R. G.; Cunha, Margarida S.; Avelino, Pedro P.; Chaplin, William J.; Campante, Tiago L.
2017-10-01
The activity-related variations in the solar acoustic frequencies have been known for 30 years. However, the importance of the different contributions is still not well established. With this in mind, we developed an empirical model to estimate the spot-induced frequency shifts, which takes into account the sunspot properties, such as area and latitude. The comparison between the model frequency shifts obtained from the daily sunspot records and those observed suggests that the contribution from a stochastic component to the total frequency shifts is about 30%. The remaining 70% is related to a global, long-term variation. We also propose a new observable to investigate the short-and mid-term variations of the frequency shifts, which is insensitive to the long-term variations contained in the data. On the shortest time scales the variations in the frequency shifts are strongly correlated with the variations in the total area covered by sunspots. However, a significant loss of correlation is still found, which cannot be fully explained by ignoring the invisible side of the Sun when accounting for the total sunspot area. We also verify that the times when the frequency shifts and the sunspot areas do not vary in a similar way tend to coincide with the times of the maximum amplitude of the quasi-biennial variations found in the seismic data.
Frequency shifts in gravitational resonance spectroscopy
Baeßler, S.; Nesvizhevsky, V. V.; Pignol, G.; ...
2015-02-25
Quantum states of ultracold neutrons in a gravitational field are characterized through gravitational resonance spectroscopy. This paper discusses systematic effects that appear in the spectroscopic measurements. The discussed frequency shifts-which we call the Stern-Gerlach shift, interference shift, and spectator-state shift-appear in conceivable measurement schemes and have general importance. Lastly, these shifts have to be taken into account in precision experiments.
NASA Astrophysics Data System (ADS)
Perreard, I. M.; Pattison, A. J.; Doyley, M.; McGarry, M. D. J.; Barani, Z.; Van Houten, E. E.; Weaver, J. B.; Paulsen, K. D.
2010-11-01
The mechanical model commonly used in magnetic resonance elastography (MRE) is linear elasticity. However, soft tissue may exhibit frequency- and direction-dependent (FDD) shear moduli in response to an induced excitation causing a purely linear elastic model to provide an inaccurate image reconstruction of its mechanical properties. The goal of this study was to characterize the effects of reconstructing FDD data using a linear elastic inversion (LEI) algorithm. Linear and FDD phantoms were manufactured and LEI images were obtained from time-harmonic MRE acquisitions with variations in frequency and driving signal amplitude. LEI responses to artificially imposed uniform phase shifts in the displacement data from both purely linear elastic and FDD phantoms were also evaluated. Of the variety of FDD phantoms considered, LEI appeared to tolerate viscoelastic data-model mismatch better than deviations caused by poroelastic and anisotropic mechanical properties in terms of visual image contrast. However, the estimated shear modulus values were substantially incorrect relative to independent mechanical measurements even in the successful viscoelastic cases and the variations in mean values with changes in experimental conditions associated with uniform phase shifts, driving signal frequency and amplitude were unpredictable. Overall, use of LEI to reconstruct data acquired in phantoms with FDD material properties provided biased results under the best conditions and significant artifacts in the worst cases. These findings suggest that the success with which LEI is applied to MRE data in tissue will depend on the underlying mechanical characteristics of the tissues and/or organs systems of clinical interest.
Perreard, I M; Pattison, A J; Doyley, M; McGarry, M D J; Barani, Z; Van Houten, E E; Weaver, J B; Paulsen, K D
2010-11-21
The mechanical model commonly used in magnetic resonance elastography (MRE) is linear elasticity. However, soft tissue may exhibit frequency- and direction-dependent (FDD) shear moduli in response to an induced excitation causing a purely linear elastic model to provide an inaccurate image reconstruction of its mechanical properties. The goal of this study was to characterize the effects of reconstructing FDD data using a linear elastic inversion (LEI) algorithm. Linear and FDD phantoms were manufactured and LEI images were obtained from time-harmonic MRE acquisitions with variations in frequency and driving signal amplitude. LEI responses to artificially imposed uniform phase shifts in the displacement data from both purely linear elastic and FDD phantoms were also evaluated. Of the variety of FDD phantoms considered, LEI appeared to tolerate viscoelastic data-model mismatch better than deviations caused by poroelastic and anisotropic mechanical properties in terms of visual image contrast. However, the estimated shear modulus values were substantially incorrect relative to independent mechanical measurements even in the successful viscoelastic cases and the variations in mean values with changes in experimental conditions associated with uniform phase shifts, driving signal frequency and amplitude were unpredictable. Overall, use of LEI to reconstruct data acquired in phantoms with FDD material properties provided biased results under the best conditions and significant artifacts in the worst cases. These findings suggest that the success with which LEI is applied to MRE data in tissue will depend on the underlying mechanical characteristics of the tissues and/or organs systems of clinical interest.
NASA Astrophysics Data System (ADS)
Wang, Weizhou; Zhang, Yu; Ji, Baoming; Tian, Anmin
2011-06-01
The C-Hal (Hal = Cl, Br, or I) bond-length change and the corresponding vibrational frequency shift of the C-Hal stretch upon the C-Hal ⋯Y (Y is the electron donor) halogen bond formation have been determined by using density functional theory computations. Plots of the C-Hal bond-length change versus the corresponding vibrational frequency shift of the C-Hal stretch all give straight lines. The coefficients of determination range from 0.94366 to 0.99219, showing that the correlation between the C-Hal bond-length change and the corresponding frequency shift is very good in the halogen-bonded complexes. The possible effects of vibrational coupling, computational method, and anharmonicity on the bond-length change-frequency shift correlation are discussed in detail.
Experimental observation of acoustic sub-harmonic diffraction by a grating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jingfei, E-mail: benjamin.jf.liu@gatech.edu; Declercq, Nico F., E-mail: declercqdepatin@gatech.edu
2014-06-28
A diffraction grating is a spatial filter causing sound waves or optical waves to reflect in directions determined by the frequency of the waves and the period of the grating. The classical grating equation is the governing principle that has successfully described the diffraction phenomena caused by gratings. However, in this work, we show experimental observation of the so-called sub-harmonic diffraction in acoustics that cannot be explained by the classical grating equation. Experiments indicate two physical phenomena causing the effect: internal scattering effects within the corrugation causing a phase shift and nonlinear acoustic effects generating new frequencies. This discovery expandsmore » our current understanding of the diffraction phenomenon, and it also makes it possible to better design spatial diffraction spectra, such as a rainbow effect in optics with a more complicated color spectrum than a traditional rainbow. The discovery reveals also a possibly new technique to study nonlinear acoustics by exploitation of the natural spatial filtering effect inherent to an acoustic diffraction grating.« less
Performance analysis of ultrasono-therapy transducer with contact detection.
Moreno, Eduardo; González, Gilberto; Leija, Lorenzo; Rodríguez, Orlando; Castillo, Martha; Fuentes, Martín
2003-06-01
The performance of ultrasono-therapy transducer with contact detection by using the impedance phase change is described. Usually a therapy transducer is designed with a lambda/2 frontal plate glued to a PZT-4 piezoceramic. This plate ensures a good mechanical protection of the piezoceramic with a corresponding high-transmission energy. Normally this transducer is operated at the minimum at the frequency of the impedance module of its input electric impedance, but this operation point is affected by the shift caused by the expected temperature increase. This shift could be higher than the narrow bandwidth presented. As a result we obtain a decrease in the power level for medical treatment. Usually it is designed electronic drivers with automatic control that follow the frequency change, but the relatively narrow bandwidth introduces difficulty in the design. Another frequency operation point is presented here and analyzed using the criteria of the maximum of the impedance phase with a wider bandwidth than in the previous case. Simulation with mechanical losses are presented with experimental results that show the convenience of this criteria for practical application.
Multi-Mode Excitation and Data Reduction for Fatigue Crack Characterization in Conducting Plates
NASA Technical Reports Server (NTRS)
Wincheski, B.; Namkung, M.; Fulton, J. P.; Clendenin, C. G.
1992-01-01
Advances in the technique of fatigue crack characterization by resonant modal analysis have been achieved through a new excitation mechanism and data reduction of multiple resonance modes. A non-contacting electromagnetic device is used to apply a time varying Lorentz force to thin conducting sheets. The frequency and direction of the Lorentz force are such that resonance modes are generated in the test sample. By comparing the change in frequency between distinct resonant modes of a sample, detecting and sizing of fatigue cracks are achieved and frequency shifts caused by boundary condition changes can be discriminated against. Finite element modeling has been performed to verify experimental results.
Quantitation Error in 1H MRS Caused by B1 Inhomogeneity and Chemical Shift Displacement.
Watanabe, Hidehiro; Takaya, Nobuhiro
2017-11-08
The quantitation accuracy in proton magnetic resonance spectroscopy ( 1 H MRS) improves at higher B 0 field. However, a larger chemical shift displacement (CSD) and stronger B 1 inhomogeneity exist. In this work, we evaluate the quantitation accuracy for the spectra of metabolite mixtures in phantom experiments at 4.7T. We demonstrate a position-dependent error in quantitation and propose a correction method by measuring water signals. All experiments were conducted on a whole-body 4.7T magnetic resonance (MR) system with a quadrature volume coil for transmission and reception. We arranged three bottles filled with metabolite solutions of N-acetyl aspartate (NAA) and creatine (Cr) in a vertical row inside a cylindrical phantom filled with water. Peak areas of three singlets of NAA and Cr were measured on three 1 H spectra at three volume of interests (VOIs) inside three bottles. We also measured a series of water spectra with a shifted carrier frequency and measured a reception sensitivity map. The ratios of NAA and Cr at 3.92 ppm to Cr at 3.01 ppm differed amongst the three VOIs in peak area, which leads to a position-dependent error. The nature of slope depicting the relationship between peak areas and the shifted values of frequency was like that between the reception sensitivities and displacement at every VOI. CSD and inhomogeneity of reception sensitivity cause amplitude modulation along the direction of chemical shift on the spectra, resulting in a quantitation error. This error may be more significant at higher B 0 field where CSD and B 1 inhomogeneity are more severe. This error may also occur in reception using a surface coil having inhomogeneous B 1 . Since this type of error is around a few percent, the data should be analyzed with greater attention while discussing small differences in the studies of 1 H MRS.
Optimized two-frequency phase-measuring-profilometry light-sensor temporal-noise sensitivity.
Li, Jielin; Hassebrook, Laurence G; Guan, Chun
2003-01-01
Temporal frame-to-frame noise in multipattern structured light projection can significantly corrupt depth measurement repeatability. We present a rigorous stochastic analysis of phase-measuring-profilometry temporal noise as a function of the pattern parameters and the reconstruction coefficients. The analysis is used to optimize the two-frequency phase measurement technique. In phase-measuring profilometry, a sequence of phase-shifted sine-wave patterns is projected onto a surface. In two-frequency phase measurement, two sets of pattern sequences are used. The first, low-frequency set establishes a nonambiguous depth estimate, and the second, high-frequency set is unwrapped, based on the low-frequency estimate, to obtain an accurate depth estimate. If the second frequency is too low, then depth error is caused directly by temporal noise in the phase measurement. If the second frequency is too high, temporal noise triggers ambiguous unwrapping, resulting in depth measurement error. We present a solution for finding the second frequency, where intensity noise variance is at its minimum.
Frequency-noise cancellation in semiconductor lasers by nonlinear heterodyne detection.
Bondurant, R S; Welford, D; Alexander, S B; Chan, V W
1986-12-01
The bit-error-rate (BER) performance of conventional noncoherent, heterodyne frequency-shift-keyed (FSK) optical communications systems can be surpassed by the use of a differential FSK modulation format and nonlinear postdetection processing at the receiver. A BER floor exists for conventional frequency-shift keying because of the frequency noise of the transmitter and local oscillator. The use of differential frequency-shift keying with nonlinear postdetection processing suppresses this BER floor for the semiconductor laser system considered here.
Light beam frequency comb generator
Priatko, G.J.; Kaskey, J.A.
1992-11-24
A light beam frequency comb generator uses an acousto-optic modulator to generate a plurality of light beams with frequencies which are uniformly separated and possess common noise and drift characteristics. A well collimated monochromatic input light beam is passed through this modulator to produce a set of both frequency shifted and unshifted optical beams. An optical system directs one or more frequency shifted beams along a path which is parallel to the path of the input light beam such that the frequency shifted beams are made incident on the modulator proximate to but separated from the point of incidence of the input light beam. After the beam is thus returned to and passed through the modulator repeatedly, a plurality of mutually parallel beams are generated which are frequency-shifted different numbers of times and possess common noise and drift characteristics. 2 figs.
Light beam frequency comb generator
Priatko, Gordon J.; Kaskey, Jeffrey A.
1992-01-01
A light beam frequency comb generator uses an acousto-optic modulator to generate a plurality of light beams with frequencies which are uniformly separated and possess common noise and drift characteristics. A well collimated monochromatic input light beam is passed through this modulator to produce a set of both frequency shifted and unshifted optical beams. An optical system directs one or more frequency shifted beams along a path which is parallel to the path of the input light beam such that the frequency shifted beams are made incident on the modulator proximate to but separated from the point of incidence of the input light beam. After the beam is thus returned to and passed through the modulator repeatedly, a plurality of mutually parallel beams are generated which are frequency-shifted different numbers of times and possess common noise and drift characteristics.
NASA Astrophysics Data System (ADS)
Ishikawa, K.; Yatabe, K.; Ikeda, Y.; Oikawa, Y.; Onuma, T.; Niwa, H.; Yoshii, M.
2017-02-01
Imaging of sound aids the understanding of the acoustical phenomena such as propagation, reflection, and diffraction, which is strongly required for various acoustical applications. The imaging of sound is commonly done by using a microphone array, whereas optical methods have recently been interested due to its contactless nature. The optical measurement of sound utilizes the phase modulation of light caused by sound. Since light propagated through a sound field changes its phase as proportional to the sound pressure, optical phase measurement technique can be used for the sound measurement. Several methods including laser Doppler vibrometry and Schlieren method have been proposed for that purpose. However, the sensitivities of the methods become lower as a frequency of sound decreases. In contrast, since the sensitivities of the phase-shifting technique do not depend on the frequencies of sounds, that technique is suitable for the imaging of sounds in the low-frequency range. The principle of imaging of sound using parallel phase-shifting interferometry was reported by the authors (K. Ishikawa et al., Optics Express, 2016). The measurement system consists of a high-speed polarization camera made by Photron Ltd., and a polarization interferometer. This paper reviews the principle briefly and demonstrates the high-speed imaging of acoustical phenomena. The results suggest that the proposed system can be applied to various industrial problems in acoustical engineering.
Optical pressure/density measuring means
Veligdan, James T.
1995-05-09
An apparatus and method for rapidly and accurately determining the pressure of a fluid medium in either a static or dynamic state. The pressure is determined by making a measurement of the velocity of a light beam that is directed through the fluid medium along a pathway that enables an integrated pressure measurement to be made along the pathway, rather than making such a measurement only at a single point in the medium. A HeNe laser is configured to emit a beam of two frequencies separated by about 2 MHz. One of these beam frequencies is directed through the fluid medium and is reflected back through the medium to a non-linear diode detector. The other beam frequency is passed directly to a diode detector without traversing said medium. The diode detector is operated to determine the frequency shift or beat frequency between the two beam frequencies. Any variation in the frequency of said reflected beam that is caused by a change in its velocity as it is passed through the fluid medium causes a change in the beat frequency. This beat frequency change is then converted to an output signal value corresponding to the pressure of the medium. The measurement instrument apparatus is remotely positioned relative to the medium being measured, thus the apparatus is immune from electro-magnetic interference and can operate in conditions of high radiation, corrosion and extraordinarily high temperature.
Optical pressure/density measuring means
Veligdan, J.T.
1995-05-09
An apparatus and method are disclosed for rapidly and accurately determining the pressure of a fluid medium in either a static or dynamic state. The pressure is determined by making a measurement of the velocity of a light beam that is directed through the fluid medium along a pathway that enables an integrated pressure measurement to be made along the pathway, rather than making such a measurement only at a single point in the medium. A HeNe laser is configured to emit a beam of two frequencies separated by about 2 MHz. One of these beam frequencies is directed through the fluid medium and is reflected back through the medium to a non-linear diode detector. The other beam frequency is passed directly to a diode detector without traversing said medium. The diode detector is operated to determine the frequency shift or beat frequency between the two beam frequencies. Any variation in the frequency of said reflected beam that is caused by a change in its velocity as it is passed through the fluid medium causes a change in the beat frequency. This beat frequency change is then converted to an output signal value corresponding to the pressure of the medium. The measurement instrument apparatus is remotely positioned relative to the medium being measured, thus the apparatus is immune from electro-magnetic interference and can operate in conditions of high radiation, corrosion and extraordinarily high temperature. 4 figs.
A physiological frequency-position map of the chinchilla cochlea.
Müller, Marcus; Hoidis, Silvi; Smolders, Jean W T
2010-09-01
Accumulating evidence indicates that mammalian cochlear frequency-position maps (location of maximum vibration of the basilar membrane as a function of frequency) depend on the physiological condition of the inner ear. Cochlear damage desensitizes the ear, after the damage the original location of maximum vibration is tuned to a lower sound frequency. This suggests that frequency-position maps, derived from such desensitized ears, are shifted to lower frequencies, corresponding to a shift of the basilar membrane vibration pattern towards the base for a given stimulus frequency. To test this hypothesis, we re-mapped the cochlear frequency-position map in the chinchilla. We collected frequency-position data from chinchillas in normal physiological condition ("physiological map") and compared these to data previously established from sound overexposed ears ("anatomical map"). The characteristic frequency (CF) of neurons in the cochlear nucleus was determined. Horse-radish peroxidase (HRP) or biocytin (BCT) were injected iontophoretically to trace auditory nerve fibers towards their innervation site in the organ of Corti. The relationship between distance from the base (d, percent) and frequency (f, kHz) was described best by a simple exponential function: d = 61.2 - 42.2 x log(f). The slope of the function was 2.55 mm/octave. Compared to the "anatomical map", the "physiological map" was shifted by about 0.3 octaves to higher frequencies corresponding to a shift of the basilar membrane vibration pattern of 0.8 mm towards the apex for a given stimulus frequency. Our findings affirm that frequency-position maps in the mammalian cochlea depend on the condition of the inner ear. Damage-induced desensitization in mammalian inner ears results in similar shifts of CF (about 0.5 octaves) but different shifts of the maximum of the vibration pattern towards the base at given frequencies, dependent on the mapping constant of the species, longer basilar membranes showing a larger basal shift. Furthermore, the results substantiate the notion that "crowding" at lower frequencies appears to be a specialization rather than a general feature. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Aging studies on micro-fabricated alkali buffer-gas cells for miniature atomic clocks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdullah, S.; Affolderbach, C.; Gruet, F.
2015-04-20
We report an aging study on micro-fabricated alkali vapor cells using neon as a buffer gas. An experimental atomic clock setup is used to measure the cell's intrinsic frequency, by recording the clock frequency shift at different light intensities and extrapolating to zero intensity. We find a drift of the cell's intrinsic frequency of (−5.2 ± 0.6) × 10{sup −11}/day and quantify deterministic variations in sources of clock frequency shifts due to the major physical effects to identify the most probable cause of the drift. The measured drift is one order of magnitude stronger than the total frequency variations expected from clock parameter variationsmore » and corresponds to a slow reduction of buffer gas pressure inside the cell, which is compatible with the hypothesis of loss of Ne gas from the cell due to its permeation through the cell windows. A negative drift on the intrinsic cell frequency is reproducible for another cell of the same type. Based on the Ne permeation model and the measured cell frequency drift, we determine the permeation constant of Ne through borosilicate glass as (5.7 ± 0.7) × 10{sup −22} m{sup 2} s{sup −1 }Pa{sup −1} at 81 °C. We propose this method based on frequency metrology in an alkali vapor cell atomic clock setup based on coherent population trapping for measuring permeation constants of inert gases.« less
Resonant nonlinear ultrasound spectroscopy
Johnson, Paul A.; TenCate, James A.; Guyer, Robert A.; Van Den Abeele, Koen E. A.
2001-01-01
Components with defects are identified from the response to strains applied at acoustic and ultrasound frequencies. The relative resonance frequency shift .vertline..DELTA..function./.function..sub.0.vertline., is determined as a function of applied strain amplitude for an acceptable component, where .function..sub.0 is the frequency of the resonance peak at the lowest amplitude of applied strain and .DELTA..function. is the frequency shift of the resonance peak of a selected mode to determine a reference relationship. Then, the relative resonance frequency shift .vertline..DELTA..function./.function..sub.0 is determined as a function of applied strain for a component under test, where fo .function..sub.0 the frequency of the resonance peak at the lowest amplitude of applied strain and .DELTA..function. is the frequency shift of the resonance peak to determine a quality test relationship. The reference relationship is compared with the quality test relationship to determine the presence of defects in the component under test.
Laser frequency stabilization and shifting by using modulation transfer spectroscopy
NASA Astrophysics Data System (ADS)
Cheng, Bing; Wang, Zhao-Ying; Wu, Bin; Xu, Ao-Peng; Wang, Qi-Yu; Xu, Yun-Fei; Lin, Qiang
2014-10-01
The stabilizing and shifting of laser frequency are very important for the interaction between the laser and atoms. The modulation transfer spectroscopy for the 87Rb atom with D2 line transition F = 2 → F' = 3 is used for stabilizing and shifting the frequency of the external cavity grating feedback diode laser. The resonant phase modulator with electro—optical effect is used to generate frequency sideband to lock the laser frequency. In the locking scheme, circularly polarized pump- and probe-beams are used. By optimizing the temperature of the vapor, the pump- and probe-beam intensity, the laser linewidth of 280 kHz is obtained. Furthermore, the magnetic field generated by a solenoid is added into the system. Therefore the system can achieve the frequency locking at any point in a range of hundreds of megahertz frequency shifting with very low power loss.
Zhang, Shangjian; Wang, Heng; Zou, Xinhai; Zhang, Yali; Lu, Rongguo; Liu, Yong
2015-06-15
An extinction-ratio-independent electrical method is proposed for measuring chirp parameters of Mach-Zehnder electric-optic intensity modulators based on frequency-shifted optical heterodyne. The method utilizes the electrical spectrum analysis of the heterodyne products between the intensity modulated optical signal and the frequency-shifted optical carrier, and achieves the intrinsic chirp parameters measurement at microwave region with high-frequency resolution and wide-frequency range for the Mach-Zehnder modulator with a finite extinction ratio. Moreover, the proposed method avoids calibrating the responsivity fluctuation of the photodiode in spite of the involved photodetection. Chirp parameters as a function of modulation frequency are experimentally measured and compared to those with the conventional optical spectrum analysis method. Our method enables an extinction-ratio-independent and calibration-free electrical measurement of Mach-Zehnder intensity modulators by using the high-resolution frequency-shifted heterodyne technique.
Multi-pulse frequency shifted (MPFS) multiple access modulation for ultra wideband
Nekoogar, Faranak [San Ramon, CA; Dowla, Farid U [Castro Valley, CA
2012-01-24
The multi-pulse frequency shifted technique uses mutually orthogonal short duration pulses o transmit and receive information in a UWB multiuser communication system. The multiuser system uses the same pulse shape with different frequencies for the reference and data for each user. Different users have a different pulse shape (mutually orthogonal to each other) and different transmit and reference frequencies. At the receiver, the reference pulse is frequency shifted to match the data pulse and a correlation scheme followed by a hard decision block detects the data.
[Effect of the night shift work on micturition patterns of nurses].
Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X
2016-02-18
To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.
[Effect of the night shift work on micturition patterns of nurses].
Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X
2016-08-18
To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.
Network synchronization in hippocampal neurons.
Penn, Yaron; Segal, Menahem; Moses, Elisha
2016-03-22
Oscillatory activity is widespread in dynamic neuronal networks. The main paradigm for the origin of periodicity consists of specialized pacemaking elements that synchronize and drive the rest of the network; however, other models exist. Here, we studied the spontaneous emergence of synchronized periodic bursting in a network of cultured dissociated neurons from rat hippocampus and cortex. Surprisingly, about 60% of all active neurons were self-sustained oscillators when disconnected, each with its own natural frequency. The individual neuron's tendency to oscillate and the corresponding oscillation frequency are controlled by its excitability. The single neuron intrinsic oscillations were blocked by riluzole, and are thus dependent on persistent sodium leak currents. Upon a gradual retrieval of connectivity, the synchrony evolves: Loose synchrony appears already at weak connectivity, with the oscillators converging to one common oscillation frequency, yet shifted in phase across the population. Further strengthening of the connectivity causes a reduction in the mean phase shifts until zero-lag is achieved, manifested by synchronous periodic network bursts. Interestingly, the frequency of network bursting matches the average of the intrinsic frequencies. Overall, the network behaves like other universal systems, where order emerges spontaneously by entrainment of independent rhythmic units. Although simplified with respect to circuitry in the brain, our results attribute a basic functional role for intrinsic single neuron excitability mechanisms in driving the network's activity and dynamics, contributing to our understanding of developing neural circuits.
BAW sensor readout circuit based on Pierce oscillator architecture
NASA Astrophysics Data System (ADS)
Gao, Yang; Yin, Xi-Yang; Han, Bin; Wang, Yu-Hang
2017-10-01
Bulk Acoustic Wave Resonators (BAWRs) have been well developed both as filters and as high sensitivity sensors in recent years. In contrast to traditional megahertz quartz resonators, BAWRs offer significant increases in resonant frequency, typically operating in gigahertz regimes. This translates into a potential sensitivity increase of more than three orders of magnitude over traditional QCM (Quartz Crystal Microbalance) devices. Given the micrometer-scale size of BAW sensor-head, read-out circuitry can monolithic integrated with this GHz transducer is urgently needed to produce small, robust, and inexpensive sensor systems. A BAW sensor read-out circuit prototype based on Pierce oscillator architecture is fulfilled in this paper. Based on the differential measurement scheme, two uniform BAWRs are used to constitute two BAW oscillators as a reference and a measurement branch respectively. The resonant frequency shift caused by the measurand is obtained by mixing and filtering the two oscillator signals. Then, the intermediate signal is amplified, shaped and converted to a digital one. And a FPGA is used for frequency detection. Taking 2 GHz BAW mass sensor as a case study, deign procedure are given in details. Simulation and experimental results reveal a 0-99 MHz frequency shift measurement range. Main factors affecting phase noise of the BAW oscillator (i.e. mainly frequency stability of the BAW sensor readout circuit) are also discussed for further optimizations.
Interface induced spin-orbit interaction in silicon quantum dots and prospects of scalability
NASA Astrophysics Data System (ADS)
Ferdous, Rifat; Wai, Kok; Veldhorst, Menno; Hwang, Jason; Yang, Henry; Klimeck, Gerhard; Dzurak, Andrew; Rahman, Rajib
A scalable quantum computing architecture requires reproducibility over key qubit properties, like resonance frequency, coherence time etc. Randomness in these properties would necessitate individual knowledge of each qubit in a quantum computer. Spin qubits hosted in Silicon (Si) quantum dots (QD) is promising as a potential building block for a large-scale quantum computer, because of their longer coherence times. The Stark shift of the electron g-factor in these QDs has been used to selectively address multiple qubits. From atomistic tight-binding studies we investigated the effect of interface non-ideality on the Stark shift of the g-factor in a Si QD. We find that based on the location of a monoatomic step at the interface with respect to the dot center both the sign and magnitude of the Stark shift change. Thus the presence of interface steps in these devices will cause variability in electron g-factor and its Stark shift based on the location of the qubit. This behavior will also cause varying sensitivity to charge noise from one qubit to another, which will randomize the dephasing times T2*. This predicted device-to-device variability is experimentally observed recently in three qubits fabricated at a Si/Si02 interface, which validates the issues discussed.
NASA Astrophysics Data System (ADS)
Wang, Q.; Y Zheng, C.; Liu, Z. J.; Xiao, C. Z.; Feng, Q. S.; Zhang, H. C.; He, X. T.
2018-02-01
The effect of the kinetic nonlinear frequency shift (KNFS) on backward stimulated Brillouin scattering (SBS) in homogeneous plasmas and inhomogeneous flowing plasmas is investigated by three-wave coupled-mode equations. When the positive contribution to the KNFS from electrons as well as the negative contribution from ions is included, the net KNFS can become positive at a large electron-ion temperature ratio {{ZT}}e/{T}i. In homogeneous plasmas, KNFS can greatly reduce the SBS reflectivity at low or large {{ZT}}e/{T}i but has a weak effect on SBS at {{ZT}}e/{T}i where the positive frequency shifts from electrons almost cancels out the negative shifts from ions. In inhomogeneous plasmas, the net negative frequency shift can enhance the backward SBS reflectivity for the negative gradient of the plasma flowing, and can suppress the reflectivity for the positive case. On the contrary, the net positive frequency can suppress the reflectivity for the negative case of the flowing gradient and enhance the reflectivity for the positive case. This indicates that the SBS in inhomogeneous flowing plasmas can be controlled by changing the sign of the nonlinear frequency shift.
Pastrav, L C; Devos, J; Van der Perre, G; Jaecques, S V N
2009-05-01
In total hip replacement (THR) a good initial stability of the prosthetic stem in the femur, which corresponds to a good overall initial contact, will help assure a good long-term result. During the insertion the implant stability increases and, as a consequence, the resonance frequencies increase, allowing the assessment of the implant fixation by vibration analysis. The influence of changing contact conditions on the resonance frequencies was however not yet quantitatively understood and therefore a finite element analysis (FEA) was set up. Modal analyses on the hip stem-femur system were performed in various contact situations. By modelling the contact changes by means of the contact tolerance options in the finite element software, contact could be varied over the entire hip stem surface or only in specific zones (proximal, central, distal) while keeping other system parameters constant. The results are in agreement with previous observations: contact increase causes positive resonance frequency shifts and the dynamic behaviour is most influenced by contact changes in the proximal zone. Although the finite element analysis did not establish a monotonous relationship between the vibrational mode number and the magnitude of the resonance frequency shift, in general the higher modes are more sensitive to the contact change.
Tissue specific resonance frequencies of water and metabolites within the human brain
NASA Astrophysics Data System (ADS)
Chadzynski, Grzegorz L.; Bender, Benjamin; Groeger, Adriane; Erb, Michael; Klose, Uwe
2011-09-01
Chemical shift imaging (CSI) without water suppression was used to examine tissue-specific resonance frequencies of water and metabolites within the human brain. The aim was to verify if there are any regional differences in those frequencies and to determine the influence of chemical shift displacement in slice-selection direction. Unsuppressed spectra were acquired at 3 T from nine subjects. Resonance frequencies of water and after water signal removal of total choline, total creatine and NAA were estimated. Furthermore, frequency distances between the water and those resonances were calculated. Results were corrected for chemical shift displacement. Frequency distances between water and metabolites were consistent and greater for GM than for WM. The highest value of WM to GM difference (14 ppb) was observed for water to NAA frequency distance. This study demonstrates that there are tissue-specific differences between frequency distances of water and metabolites. Moreover, the influence of chemical shift displacement in slice-selection direction is showed to be negligible.
Tissue specific resonance frequencies of water and metabolites within the human brain.
Chadzynski, Grzegorz L; Bender, Benjamin; Groeger, Adriane; Erb, Michael; Klose, Uwe
2011-09-01
Chemical shift imaging (CSI) without water suppression was used to examine tissue-specific resonance frequencies of water and metabolites within the human brain. The aim was to verify if there are any regional differences in those frequencies and to determine the influence of chemical shift displacement in slice-selection direction. Unsuppressed spectra were acquired at 3T from nine subjects. Resonance frequencies of water and after water signal removal of total choline, total creatine and NAA were estimated. Furthermore, frequency distances between the water and those resonances were calculated. Results were corrected for chemical shift displacement. Frequency distances between water and metabolites were consistent and greater for GM than for WM. The highest value of WM to GM difference (14ppb) was observed for water to NAA frequency distance. This study demonstrates that there are tissue-specific differences between frequency distances of water and metabolites. Moreover, the influence of chemical shift displacement in slice-selection direction is showed to be negligible. Copyright © 2011 Elsevier Inc. All rights reserved.
Rotating shift work and menstrual characteristics in a cohort of Chinese nurses.
Wang, Yizi; Gu, Fang; Deng, Mingfen; Guo, Lan; Lu, Ciyong; Zhou, Canquan; Chen, Shouzhen; Xu, Yanwen
2016-05-04
Shift work disrupts the circadian rhythm and may cause menstruation disorders. This study assessed the impact of shift work on menstrual cycle in a population of Chinese nurses. Questionnaires on menstrual characteristics and shift schedules were sent to female nurses of the First Affiliated Hospital of Sun Yat-sen University (FAHSYSU) and Guanghua Hospital of Stomatology (GHHS), affiliated to Sun Yat-sen University. Part I was a cross-sectional study and included 139 nurses in GHHS who had regular 8:00-17:30 working (non-shift group), and 334 nurses from FAHSYSU who worked shifts, a response rate of 67.5 % and 59.6 %, respectively (age ≤ 50 years). Menstrual patterns were compared and age-adjusted relative risks of shift work were analyzed. Part II was a nested case-control study. Cases were nurses in Part I who had regular cycle with mean cycle length (MCL) of 25-31 days and but at least 3 days variation in MCL after starting shift work (n = 45). Controls consisted of 67 nurses with matching shift patterns and age, but no MCL changes. A control non-shift age-matched group consisted of 30 GHHS nurses with no MCL changes. A follow-up second questionnaire was sent 2 years later. In Part I, the shift group had a significantly higher proportion of nurses with menstrual cycle irregularity. The proportion of nurses with a cycle of 25-31 days decreased from 81.7 to 67.8 % after changing to shift work. Logistic regression analysis showed that night shift frequency was the only risk factor associated with cycle shortening. After adjusting for age, MCL was shorter when night work was performed > 7 times per month. In Part II, the mean change in MCL in the case group, including prolongation or shortening, was 4.115 ± 2.084 days after shift working. In the 2 years' follow-up, the MCL of the study group did not recover to the original length. Rotating shift work can increase the prevalence of menstrual cycle irregularity. Night shift frequency was the only risk factor associated with cycle reduced. Changes in MCL did not show recovery over a follow-up period of 2 years.
Ultrasonic ranging for the oculometer
NASA Technical Reports Server (NTRS)
Guy, W. J.
1981-01-01
Ultrasonic tracking techniques are investigated for an oculometer. Two methods are reported in detail. The first is based on measurements of time from the start of a transmit burst to a received echo. Knowing the sound velocity, distance can be calculated. In the second method, a continuous signal is transmitted. Target movement causes phase shifting of the echo. By accumulating these phase shifts, tracking from a set point can be achieved. Both systems have problems with contoured targets, but work well on flat plates and the back of a human head. Also briefly reported is an evaluation of an ultrasonic ranging system. Interface circuits make this system compatible with the echo time design. While the system is consistently accurate, it has a beam too narrow for oculometer use. Finally, comments are provided on a tracking system using the Doppler frequency shift to give range data.
The second filter’s second coming
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramamoorthy, Sripriya; Jacques, Steven L.; Choudhoury, Niloy
We measured sound-evoked vibrations at the stereociliary side of inner and outer hair cells and their surrounding supporting cells, using optical coherence tomography interferometry in living anesthetized guinea pigs. Our measurements demonstrate a gradient in frequency tuning among different cell types, going from a high best frequency at the inner hair cells to a lower one at the Hensen cells. This causes the locus of maximum inner hair cell activation to be shifted toward the apex of the cochlea as compared to the outer hair cells. These observations show that additional processing and filtering of acoustic signals occurs within themore » organ of Corti prior to inner hair cell excitation, thus reinstating a transformed second filter as a mechanism contributing to cochlear frequency tuning.« less
The second filter's second coming
NASA Astrophysics Data System (ADS)
Ramamoorthy, Sripriya; Chen, Fangyi; Zha, Dingjun; Jacques, Steven L.; Wang, Ruikang; Choudhoury, Niloy; Nuttall, Alfred L.; Fridberger, Anders
2015-12-01
We measured sound-evoked vibrations at the stereociliary side of inner and outer hair cells and their surrounding supporting cells, using optical coherence tomography interferometry in living anesthetized guinea pigs. Our measurements demonstrate a gradient in frequency tuning among different cell types, going from a high best frequency at the inner hair cells to a lower one at the Hensen cells. This causes the locus of maximum inner hair cell activation to be shifted toward the apex of the cochlea as compared to the outer hair cells. These observations show that additional processing and filtering of acoustic signals occurs within the organ of Corti prior to inner hair cell excitation, thus reinstating a transformed second filter as a mechanism contributing to cochlear frequency tuning.
Liu, Bo-Wen; Hu, Ming-Lie; Fang, Xiao-Hui; Li, Yan-Feng; Chai, Lu; Wang, Ching-Yue; Tong, Weijun; Luo, Jie; Voronin, Aleksandr A; Zheltikov, Aleksei M
2008-09-15
Fiber dispersion and nonlinearity management strategy based on a modification of a photonic-crystal fiber (PCF) core with an air hole is shown to facilitate optimization of PCF components for a stable soliton frequency shift and subpetahertz sideband generation through four-wave mixing. Spectral recoil of an optical soliton by a red-shifted dispersive wave, generated through a soliton instability induced by high-order fiber dispersion, is shown to stabilize the soliton self-frequency shift in a highly nonlinear PCF with an air-hole-modified core relative to pump power variations. A fiber with a 2.3-microm-diameter core modified with a 0.9-microm-diameter air hole is used to demonstrate a robust soliton self-frequency shift of unamplified 50-fs Ti: sapphire laser pulses to a central wavelength of about 960 nm, which remains insensitive to variations in the pump pulse energy within the range from 60 to at least 100 pJ. In this regime of frequency shifting, intense high- and low-frequency branches of dispersive wave radiation are simultaneously observed in the spectrum of PCF output. An air-hole-modified-core PCF with appropriate dispersion and nonlinearity parameters is shown to provide efficient four-wave mixing, giving rise to Stokes and anti-Stokes sidebands whose frequency shift relative to the pump wavelength falls within the subpetahertz range, thus offering an attractive source for nonlinear Raman microspectroscopy.
Effect of Shift Work on Nocturia.
Kim, Jin Wook
2016-01-01
To identify the circadian sensitive component of nocturia by comparing nocturia in patients who voluntarily choose a disrupted circadian rhythm, that is, shift workers, with those who maintain normal day-night cycles. Between 2011 and 2013, a total of 1741 untreated patients, 1376 nonshift workers and 365 shift workers, were compared for nocturia indices based on frequency volume charts (FVCs). General linear model of 8-hour interval urine production and frequency were compared between FVCs of nonshift workers, FVCs of night-shift workers, and FVCs of day-shift workers. Nocturia frequency was increased in the night-shift workers (2.38 ± 1.44) compared with nonshift workers (2.18 ± 1.04) (P <.01). Whereas nocturnal polyuria index did not increase significantly (0.33 ± 0.19 for night-shift workers, 0.34 ± 0.13 for nonshift workers, P = .24), nocturnal bladder capacity index increased significantly (1.41 ± 1.06 for night-shift workers, 1.26 ± 0.92 for nonshift workers, P <.01). Eight-hour interval indices show that urine production changed with shift (P <.01), whereas voiding frequency remains unchanged despite shift changes (P = .35). Patients in alternating work shifts showed increased nocturia, especially during their night shift. These changes tended to be more associated with decreased nocturnal bladder capacity than increased nocturnal polyuria. Copyright © 2015 Elsevier Inc. All rights reserved.
Microwave measurement of the mass of frozen hydrogen pellets
Talanker, Vera; Greenwald, Martin
1990-01-01
A nondestructive apparatus and method for measuring the mass of a moving object, based on the perturbation of the dielectric character of a resonant microwave cavity caused by the object passing through the cavity. An oscillator circuit is formed with a resonant cavity in a positive feedback loop of a microwave power amplifier. The moving object perturbs the resonant characteristics of the cavity causing a shift in the operating frequency of the oscillator proportional to the ratio of the pellet volume to the volume of the cavity. Signals from the cavity oscillation are mixed with a local oscillator. Then the IF frequency from the mixer is measured thereby providing a direct measurement of pellet mass based upon known physical properties and relationships. This apparatus and method is particularly adapted for the measurement of frozen hydrogen pellets.
Influence of rate of change of frequency on the overall pitch of frequency-modulated tones.
Gockel, H; Moore, B C; Carlyon, R P
2001-02-01
The mechanism(s) determining pitch may assign less weight to portions of a sound where the frequency is changing rapidly. The present experiments explored the possible effect of this on the overall pitch of frequency-modulated sounds. Pitch matches were obtained between an adjustable unmodulated sinusoid and a sinusoidal carrier that was frequency modulated using a highly asymmetric function with the form of a repeating U or inverted U shaped function. The amplitude was constant during the 400-ms presentation time of each stimulus, except for 10-ms raised-cosine onset and offset ramps. In experiment 1, the carrier level was 50 dB SPL and the geometric mean of the instantaneous frequency of the modulated carrier, fc, was either 0.5, 1, 2, or 8 kHz. The modulation rate (fm) was 5, 10, or 20 Hz. The overall depth (maximum to minimum) of the FM was 8% of fc. For all carrier frequencies, the matched frequency was shifted away from the mean carrier frequency, downwards for the U shaped function stimuli and upwards for the repeated inverted U shaped function stimuli. The shift was typically slightly greater than 1% of fc, and did not vary markedly with fc. The effect of fm was small, but there was a trend for the shifts to decrease with increasing fm for fc = 0.5 kHz and to increase with increasing fm for fc = 2 kHz. In experiment 2, the carrier level was reduced to 20 dB SL and matches were obtained only for fc = 2 kHz. Shifts in matched frequency of about 1% were still observed, but the trend for the shifts to increase with increasing fm no longer occurred. In experiment 3, matches were obtained for a 4-kHz carrier at 50 dB SPL. Shifts of about 1% again occurred, which did not vary markedly with fm. The shifts in matched frequency observed in all three experiments are not predicted by models based on the amplitude- or intensity-weighted average of instantaneous frequency (EWAIF or IWAIF). The shifts (and the pitch shifts observed earlier for two-tone complexes and for stimuli with simultaneous AM and FM) are consistent with a model based on the assumption that the overall pitch of a frequency-modulated sound is determined from a weighted average of period estimates, with the weight attached to a given estimate being inversely related to the short-term rate of change of period and directly related to a compressive function of the amplitude.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise.
Nechaev, Dmitry I; Milekhina, Olga N; Supin, Alexander Ya
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise
Nechaev, Dmitry I.; Milekhina, Olga N.; Supin, Alexander Ya.
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels. PMID:26462066
Rucker, F. J.; Osorio, D.
2009-01-01
Longitudinal chromatic aberration is a well-known imperfection of visual optics, but the consequences in natural conditions, and for the evolution of receptor spectral sensitivities are less well understood. This paper examines how chromatic aberration affects image quality in the middle-wavelength sensitive (M-) cones, viewing broad-band spectra, over a range of spatial frequencies and focal planes. We also model the effects on M-cone contrast of moving the M-cone fundamental relative to the long- and middle-wavelength (L- and M-cone) fundamentals, while the eye is accommodated at different focal planes or at a focal plane that maximizes luminance contrast. When the focal plane shifts towards longer (650 nm) or shorter wavelengths (420 nm) the effects on M-cone contrast are large: longitudinal chromatic aberration causes total loss of M-cone contrast above 10 to 20 c/d. In comparison, the shift of the M-cone fundamental causes smaller effects on M-cone contrast. At 10 c/d a shift in the peak of the M-cone spectrum from 560 nm to 460 nm decreases M-cone contrast by 30%, while a 10 nm blue-shift causes only a minor loss of contrast. However, a noticeable loss of contrast may be seen if the eye is focused at focal planes other than that which maximizes luminance contrast. The presence of separate long- and middle-wavelength sensitive cones therefore has a small, but not insignificant cost to the retinal image via longitudinal chromatic aberration. This aberration may therefore be a factor limiting evolution of visual pigments and trichromatic color vision. PMID:18639571
Building a good initial model for full-waveform inversion using frequency shift filter
NASA Astrophysics Data System (ADS)
Wang, Guanchao; Wang, Shangxu; Yuan, Sanyi; Lian, Shijie
2018-05-01
Accurate initial model or available low-frequency data is an important factor in the success of full waveform inversion (FWI). The low-frequency helps determine the kinematical relevant components, low-wavenumber of the velocity model, which are in turn needed to avoid FWI trap in local minima or cycle-skipping. However, in the field, acquiring data that <5 Hz is a challenging and expensive task. We attempt to find the common point of low- and high-frequency signal, then utilize the high-frequency data to obtain the low-wavenumber velocity model. It is well known that the instantaneous amplitude envelope of a wavelet is invariant under frequency shift. This means that resolution is constant for a given frequency bandwidth, and independent of the actual values of the frequencies. Based on this property, we develop a frequency shift filter (FSF) to build the relationship between low- and high-frequency information with a constant frequency bandwidth. After that, we can use the high-frequency information to get a plausible recovery of the low-wavenumber velocity model. Numerical results using synthetic data from the Marmousi and layer model demonstrate that our proposed envelope misfit function based on the frequency shift filter can build an initial model with more accurate long-wavelength components, when low-frequency signals are absent in recorded data.
Implications of solar p-mode frequency shifts
NASA Technical Reports Server (NTRS)
Goldreich, Peter; Murray, Norman; Willette, Gregory; Kumar, Pawan
1991-01-01
An expression is derived that relates solar p-mode frequency shifts to changes in the entropy and magnetic field of the sun. The frequency variations result from changes in path length and propagation speed. Path length changes dominate for entropy perturbations, and propagation speed changes dominate for most types of magnetic field peturbations. The p-mode frequencies increased along with solar activity between 1986 and 1989; these frequency shifts exhibited a rapid rise with increasing frequency followed by a precipitous drop. The positive component of the shifts can be accounted for by variations of the mean square magnetic field strength in the vicinity of the photosphere. The magnetic stress perturbation decays above the top of the convection zone on a length scale comparable to the pressure scale height and grows gradually with depth below. The presence of a resonance in the chromospheric cavity means that the transition layer maintains enough coherence to partially reflect acoustic waves even near cycle maximum.
Miasnikov, Alexandre A; Weinberger, Norman M
2012-11-01
Experience often does not produce veridical memory. Understanding false attribution of events constitutes an important problem in memory research. "Peak shift" is a well-characterized, controllable phenomenon in which human and animal subjects that receive reinforcement associated with one sensory stimulus later respond maximally to another stimulus in post-training stimulus generalization tests. Peak shift ordinarily develops in discrimination learning (reinforced CS+, unreinforced CS-) and has long been attributed to the interaction of an excitatory gradient centered on the CS+ and an inhibitory gradient centered on the CS-; the shift is away from the CS-. In contrast, we have obtained peak shifts during single tone frequency training, using stimulation of the cholinergic nucleus basalis (NB) to implant behavioral memory into the rat. As we also recorded cortical activity, we took the opportunity to investigate the possible existence of a neural frequency gradient that could account for behavioral peak shift. Behavioral frequency generalization gradients (FGGs, interruption of ongoing respiration) were determined twice before training while evoked potentials were recorded from the primary auditory cortex (A1), to obtain a baseline gradient of "habituatory" neural decrement. A post-training behavioral FGG obtained 24h after three daily sessions of a single tone paired with NB stimulation (200 trials/day) revealed a peak shift. The peak of the FGG was at a frequency lower than the CS while the cortical inhibitory gradient was at a frequency higher than the CS frequency. Further analysis indicated that the frequency location and magnitude of the gradient could account for the behavioral peak shift. These results provide a neural basis for a systematic case of memory misattribution and may provide an animal model for the study of the neural bases of a type of "false memory". Published by Elsevier Inc.
Decoherence and Collisional Frequency Shifts of Trapped Bosons and Fermions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibble, Kurt; LNE-SYRTE, Observatoire de Paris, 75014 Paris
2009-09-11
We perform exact calculations of collisional frequency shifts for several fermions or bosons using a singlet and triplet basis for pairs of particles. The 'factor of 2 controversy' for bosons becomes clear - the factor is always 2. Decoherence is described by singlet states and they are unaffected by spatially uniform clock fields. Spatial variations are critical, especially for fermions which were previously thought to be immune to collision shifts. The spatial variations lead to decoherence and a novel frequency shift that is not proportional to the partial density of internal states.
Takahashi, Masae; Okamura, Nubuyuki; Fan, Xinyi; Shirakawa, Hitoshi; Minamide, Hiroaki
2017-04-06
We have investigated the terahertz-spectral property of nicotinamide focusing on the temperature dependence in the range of 14-300 K. We observed that almost all peaks in the terahertz spectrum of the nicotinamide crystal showed a remarkable shift with temperature, whereas the lowest-frequency peak at 34.8 cm -1 showed a negligible shift with temperature. By analyzing the terahertz spectrum with the dispersion-corrected density functional theory calculations, we found that the difference in the temperature dependence of the peak shift is well understood in terms of the presence/absence of stretching vibration of the intermolecular hydrogen bond in the mode and the change of cell parameters. The anharmonicity in the dissociation potential energy of very weak intermolecular hydrogen bonding causes the remarkable peak shift with temperature in the terahertz spectrum of nicotinamide. This finding suggests that the assignment and identification of peaks in the terahertz spectrum are systematically enabled by temperature-dependent measurements.
NASA Astrophysics Data System (ADS)
McDowell, Sean A. C.
2017-04-01
An MP2 computational study of model hydrogen-bonded pyrrole⋯YZ (YZ = NH3, NCH, BF, CO, N2, OC, FB) complexes was undertaken in order to examine the variation of the Nsbnd H bond length change and its associated vibrational frequency shift. The chemical hardness of Y, as well as the YZ dipole moment, were found to be important parameters in modifying the bond length change/frequency shift. The basis set effect on the computed properties was also assessed. A perturbative model, which accurately reproduced the ab initio Nsbnd H bond length changes and frequency shifts, was useful in rationalizing the observed trends.
NASA Astrophysics Data System (ADS)
Kobayashi, Hiroaki; Gotoda, Hiroshi; Tachibana, Shigeru; Yoshida, Seiji
2017-12-01
We conduct an experimental study using time series analysis based on symbolic dynamics to detect a precursor of frequency-mode-shift during thermoacoustic combustion oscillations in a staged aircraft engine model combustor. With increasing amount of the main fuel, a significant shift in the dominant frequency-mode occurs in noisy periodic dynamics, leading to a notable increase in oscillation amplitudes. The sustainment of noisy periodic dynamics during thermoacoustic combustion oscillations is clearly shown by the multiscale complexity-entropy causality plane in terms of statistical complexity. A modified version of the permutation entropy allows us to detect a precursor of the frequency-mode-shift before the amplification of pressure fluctuations.
NASA Astrophysics Data System (ADS)
Ganzorig, Chimed; Fujihira, Masamichi
2004-11-01
This study examines the possibility of thermal decomposition of Na salts of acetate, benzoate, and fluoride during vacuum vapor deposition using a quartz crystal microbalance to measure negative frequency shift (Δf) caused by increasing mass deposited from the same amount of source materials. Cs acetate is also examined. We compare the negative frequency shift-source current (Δf -I) curves of the Na salts with those of organic materials such as tris(8-hydroxyquinoline)aluminum and N ,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1'-biphenyl-4,4'-diamine. CH3COONa and C6H5COONa exhibit much lower Δf than the organic materials. CH3COOCs gives much larger Δf than CH3COONa due to the higher atomic weight of Cs. These exhibit clear evidence for alkali metal formation by thermal decomposition during vapor deposition of alkali metal carboxylates.
Behavior of a Light Solid in a Rotating Horizontal Cylinder with Liquid Under Vibration
NASA Astrophysics Data System (ADS)
Karpunin, I. E.; Kozlova, A. N.; Kozlov, N. V.
2018-06-01
Dynamics of a cylindrical body in a rotating cavity is experimentally studied under transversal translational vibrations of the cavity rotation axis. Experiments are run at high rotation rate, when under the action of centrifugal force the body shifts to the rotation axis (the centrifuged state). In the absence of vibrations, the lagging rotation of the body is observed, due to the body radial shift from the axis of rotation caused by gravity. The body average rotation regime depends on the cavity rotation rate. The vibrations lead to the excitation of different regimes of body differential rotation (leading or lagging) associated with the excitation of its inertial oscillations. The dependence of the differential speed of the body rotation on the vibration frequency is investigated. The body dynamics has a complex character depending on the dimensionless vibration frequency. The analysis of body oscillation trajectory revealed that the body oscillatory motion consists of several modes, which contribute to the averaged dynamics of the body and the flows in the cavity.
Blue and red shifted temperature dependence of implicit phonon shifts in graphene
NASA Astrophysics Data System (ADS)
Mann, Sarita; Jindal, V. K.
2017-07-01
We have calculated the implicit shift for various modes of frequency in a pure graphene sheet. Thermal expansion and Grüneisen parameter which are required for implicit shift calculation have already been studied and reported. For this calculation, phonon frequencies are obtained using force constants derived from dynamical matrix calculated using VASP code where the density functional perturbation theory (DFPT) is used in interface with phonopy software. The implicit phonon shift shows an unusual behavior as compared to the bulk materials. The frequency shift is large negative (red shift) for ZA and ZO modes and the value of negative shift increases with increase in temperature. On the other hand, blue shift arises for all other longitudinal and transverse modes with a similar trend of increase with increase in temperature. The q dependence of phonon shifts has also been studied. Such simultaneous red and blue shifts in transverse or out plane modes and surface modes, respectively leads to speculation of surface softening in out of plane direction in preference to surface melting.
1985-03-15
noise are decreased by -10 dB by injection. Fabry - Perot spectra suggest a stabilisation of the optical spectrum as well. The noise is caused by...pump beam such that one of the Fabry - Perot transmission peaks is on the low-frequency side of the exciton resonance. The pump beam creates carriers...originally transmitting, the application of the pump shifts the Fabry - Perot peak away from the laser wavelength causing the transmission to decrease
NASA Astrophysics Data System (ADS)
Kishida, Ryo; Furuta, Jun; Kobayashi, Kazutoshi
2018-04-01
Plasma-induced damage (PID) and bias temperature instability (BTI) are inevitable reliability issues that degrade the performance of transistors. In this study, PID and BTI, depending on the type of antenna layer, are evaluated in current-starved ring oscillators (ROs) to separate degradations in PMOS and NMOS transistors in a 65 nm silicon-on-insulator (SOI) process. Oscillation frequencies of ROs fluctuate with the performance of MOSFET switches between power/ground rails and virtual power/ground nodes. The initial frequencies of ROs with PMOS switches having antennas on upper layers decrease. However, those with NMOS switches become higher than those without PID because high-k dielectrics are damaged by positive charges. The degradation induced by negative BTI (NBTI) in PMOS is 1.5 times larger than that induced by positive BTI (PBTI) in NMOS. However, both NBTI- and PBTI-induced degradations are the same among different antenna layers. The frequency fluctuation caused by PID is converted to threshold voltage shifts by circuit simulations. Threshold voltages shift by 8.4 and 11% owing to PID in PMOS and NMOS transistors, respectively.
NASA Technical Reports Server (NTRS)
Ahearn, J. S.; Venables, J. D.
1992-01-01
Factors determining the radiation sensitivity of quartz crystal oscillators were studied on NASA's LDEF. Quartz materials were examined in the transmission electron microscope (TEM) and classified as to their sensitivity to radiation damage by establishing the rate of damage caused by the electron beam in the microscope. Two types of materials, i.e., swept premium Q quartz and natural quartz were chosen because clear differences were observed in their response to the electron beam in the TEM studies. Quartz resonators were then fabricated from them, tested for frequency stability over a greater than 6 mo. period and flown on the LDEF satellite. After retrieval (more than 7 yrs in space) the stability of the resonators was again determined. All of the space exposed resonators fabricated with swept premium Q material exhibited a frequency shift above that of the control resonators: none of the resonators fabricated from the natural quartz materials exhibited such a shift. The significant differences observed between the two types of materials in both the ground-based TEM studies and the space radiation induced frequency changes suggest that there may be a correlation between the two observations.
Qubit-flip-induced cavity mode squeezing in the strong dispersive regime of the quantum Rabi model
Joshi, Chaitanya; Irish, Elinor K.; Spiller, Timothy P.
2017-01-01
Squeezed states of light are a set of nonclassical states in which the quantum fluctuations of one quadrature component are reduced below the standard quantum limit. With less noise than the best stabilised laser sources, squeezed light is a key resource in the field of quantum technologies and has already improved sensing capabilities in areas ranging from gravitational wave detection to biomedical applications. In this work we propose a novel technique for generating squeezed states of a confined light field strongly coupled to a two-level system, or qubit, in the dispersive regime. Utilising the dispersive energy shift caused by the interaction, control of the qubit state produces a time-dependent change in the frequency of the light field. An appropriately timed sequence of sudden frequency changes reduces the quantum noise fluctuations in one quadrature of the field well below the standard quantum limit. The degree of squeezing and the time of generation are directly controlled by the number of frequency shifts applied. Even in the presence of realistic noise and imperfections, our protocol promises to be capable of generating a useful degree of squeezing with present experimental capabilities. PMID:28358025
3D measurement using combined Gray code and dual-frequency phase-shifting approach
NASA Astrophysics Data System (ADS)
Yu, Shuang; Zhang, Jing; Yu, Xiaoyang; Sun, Xiaoming; Wu, Haibin; Liu, Xin
2018-04-01
The combined Gray code and phase-shifting approach is a commonly used 3D measurement technique. In this technique, an error that equals integer multiples of the phase-shifted fringe period, i.e. period jump error, often exists in the absolute analog code, which can lead to gross measurement errors. To overcome this problem, the present paper proposes 3D measurement using a combined Gray code and dual-frequency phase-shifting approach. Based on 3D measurement using the combined Gray code and phase-shifting approach, one set of low-frequency phase-shifted fringe patterns with an odd-numbered multiple of the original phase-shifted fringe period is added. Thus, the absolute analog code measured value can be obtained by the combined Gray code and phase-shifting approach, and the low-frequency absolute analog code measured value can also be obtained by adding low-frequency phase-shifted fringe patterns. Then, the corrected absolute analog code measured value can be obtained by correcting the former by the latter, and the period jump errors can be eliminated, resulting in reliable analog code unwrapping. For the proposed approach, we established its measurement model, analyzed its measurement principle, expounded the mechanism of eliminating period jump errors by error analysis, and determined its applicable conditions. Theoretical analysis and experimental results show that the proposed approach can effectively eliminate period jump errors, reliably perform analog code unwrapping, and improve the measurement accuracy.
Reversal of orbital angular momentum arising from an extreme Doppler shift.
Gibson, Graham M; Toninelli, Ermes; Horsley, Simon A R; Spalding, Gabriel C; Hendry, Euan; Phillips, David B; Padgett, Miles J
2018-04-10
The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes "negative." In the linear case, this effect is associated with the time reversal of the received signal, but it can be observed only with supersonic relative motion between the source and receiver. However, the rotational case is different; if the radius of rotation is smaller than the wavelength, then the velocities required to observe negative frequencies are subsonic. Using an acoustic source at [Formula: see text]100 Hz we create a rotational Doppler shift larger than the laboratory-frame frequency. We observe that once the red-shifted wave passes into the "negative frequency" regime, the angular momentum associated with the sound is reversed in sign compared with that of the laboratory frame. These low-velocity laboratory realizations of extreme Doppler shifts have relevance to superoscillatory fields and offer unique opportunities to probe interactions with rotating bodies and aspects of pseudorelativistic frame translation. Copyright © 2018 the Author(s). Published by PNAS.
Astrometric "Core-shifts" at the Highest Frequencies
NASA Technical Reports Server (NTRS)
Rioja, Maria; Dodson, Richard
2010-01-01
We discuss the application of a new VLBI astrometric method named "Source/Frequency Phase Referencing" to measurements of "core-shifts" in radio sources used for geodetic observations. We detail the reasons that astrometrical observations of 'core-shifts' have become critical in the era of VLBI2010. We detail how this new method allows the problem to be addressed at the highest frequencies and outline its superior compensation of tropospheric errors.
Automatic oscillator frequency control system
NASA Technical Reports Server (NTRS)
Smith, S. F. (Inventor)
1985-01-01
A frequency control system makes an initial correction of the frequency of its own timing circuit after comparison against a frequency of known accuracy and then sequentially checks and corrects the frequencies of several voltage controlled local oscillator circuits. The timing circuit initiates the machine cycles of a central processing unit which applies a frequency index to an input register in a modulo-sum frequency divider stage and enables a multiplexer to clock an accumulator register in the divider stage with a cyclical signal derived from the oscillator circuit being checked. Upon expiration of the interval, the processing unit compares the remainder held as the contents of the accumulator against a stored zero error constant and applies an appropriate correction word to a correction stage to shift the frequency of the oscillator being checked. A signal from the accumulator register may be used to drive a phase plane ROM and, with periodic shifts in the applied frequency index, to provide frequency shift keying of the resultant output signal. Interposition of a phase adder between the accumulator register and phase plane ROM permits phase shift keying of the output signal by periodic variation in the value of a phase index applied to one input of the phase adder.
NASA Astrophysics Data System (ADS)
Salabert, D.; Régulo, C.; Pérez Hernández, F.; García, R. A.
2018-04-01
The variations of the frequencies of the low-degree acoustic oscillations in the Sun induced by magnetic activity show a dependence on radial order. The frequency shifts are observed to increase towards higher-order modes to reach a maximum of about 0.8 μHz over the 11-yr solar cycle. A comparable frequency dependence is also measured in two other main sequence solar-like stars, the F-star HD 49933, and the young 1 Gyr-old solar analog KIC 10644253, although with different amplitudes of the shifts of about 2 μHz and 0.5 μHz, respectively. Our objective here is to extend this analysis to stars with different masses, metallicities, and evolutionary stages. From an initial set of 87 Kepler solar-like oscillating stars with known individual p-mode frequencies, we identify five stars showing frequency shifts that can be considered reliable using selection criteria based on Monte Carlo simulations and on the photospheric magnetic activity proxy Sph. The frequency dependence of the frequency shifts of four of these stars could be measured for the l = 0 and l = 1 modes individually. Given the quality of the data, the results could indicate that a physical source of perturbation different from that in the Sun is dominating in this sample of solar-like stars.
Electrophysiological correlates of figure-ground segregation directly reflect perceptual saliency.
Straube, Sirko; Grimsen, Cathleen; Fahle, Manfred
2010-03-05
In a figure identification task, we investigated the influence of different visual cue configurations (spatial frequency, orientation or a combination of both) on the human EEG. Combining psychophysics with ERP and time-frequency analysis, we show that the neural response at about 200ms reflects perceptual saliency rather than physical cue contrast. Increasing saliency caused (i) a negative shift of the posterior P2 coinciding with a power decrease in the posterior theta-band and (ii) an amplitude and latency increase of the posterior P3. We demonstrate that visual cues interact for a percept that is non-linearly related to the physical figure-ground properties.
Mechanical design and analysis of a low beta squeezed half-wave resonator
NASA Astrophysics Data System (ADS)
He, Shou-Bo; Zhang, Cong; Yue, Wei-Ming; Wang, Ruo-Xu; Xu, Meng-Xin; Wang, Zhi-Jun; Huang, Shi-Chun; Huang, Yu-Lu; Jiang, Tian-Cai; Wang, Feng-Feng; Zhang, Sheng-Xue; He, Yuan; Zhang, Sheng-Hu; Zhao, Hong-Wei
2014-08-01
A superconducting squeezed type half-wave resonator (HWR) of β=0.09 has been developed at the Institute of Modern Physics, Lanzhou. In this paper, a basic design is presented for the stiffening structure for the detuning effect caused by helium pressure and Lorentz force. The mechanical modal analysis has been investigated the with finite element method (FEM). Based on these considerations, a new stiffening structure is proposed for the HWR cavity. The computation results concerning the frequency shift show that the low beta HWR cavity with new stiffening structure has low frequency sensitivity coefficient df/dp and Lorentz force detuning coefficient KL, and stable mechanical properties.
The ac stark shift and space-borne rubidium atomic clocks
NASA Astrophysics Data System (ADS)
Formichella, V.; Camparo, J.; Sesia, I.; Signorile, G.; Galleani, L.; Huang, M.; Tavella, P.
2016-11-01
Due to its small size, low weight, and low power consumption, the Rb atomic frequency standard (RAFS) is routinely the first choice for atomic timekeeping in space. Consequently, though the device has very good frequency stability (rivaling passive hydrogen masers), there is interest in uncovering the fundamental processes limiting its long-term performance, with the goal of improving the device for future space systems and missions. The ac Stark shift (i.e., light shift) is one of the more likely processes limiting the RAFS' long-term timekeeping ability, yet its manifestation in the RAFS remains poorly understood. In part, this comes from the fact that light-shift induced frequency fluctuations must be quantified in terms of the RAFS' light-shift coefficient and the output variations in the RAFS' rf-discharge lamp, which is a nonlinear inductively-couple plasma (ICP). Here, we analyze the light-shift effect for a family of 10 on-orbit Block-IIR GPS RAFS, examining decade-long records of their on-orbit frequency and rf-discharge lamp fluctuations. We find that the ICP's light intensity variations can take several forms: deterministic aging, jumps, ramps, and non-stationary noise, each of which affects the RAFS' frequency via the light shift. Correlating these light intensity changes with RAFS frequency changes, we estimate the light-shift coefficient, κLS, for the family of RAFS: κLS = -(1.9 ± 0.3) × 10-12/%. The 16% family-wide variation in κLS indicates that while each RAFS may have its own individual κLS, the variance of κLS among similarly designed RAFS can be relatively small. Combining κLS with our estimate of the ICP light intensity's non-stationary noise, we find evidence that random-walk frequency noise in high-quality space-borne RAFS is strongly influenced by the RAFS' rf-discharge lamp via the light shift effect.
Rosen, S; Faulkner, A; Wilkinson, L
1999-12-01
Multi-channel cochlear implants typically present spectral information to the wrong "place" in the auditory nerve array, because electrodes can only be inserted partway into the cochlea. Although such spectral shifts are known to cause large immediate decrements in performance in simulations, the extent to which listeners can adapt to such shifts has yet to be investigated. Here, the effects of a four-channel implant in normal listeners have been simulated, and performance tested with unshifted spectral information and with the equivalent of a 6.5-mm basalward shift on the basilar membrane (1.3-2.9 octaves, depending on frequency). As expected, the unshifted simulation led to relatively high levels of mean performance (e.g., 64% of words in sentences correctly identified) whereas the shifted simulation led to very poor results (e.g., 1% of words). However, after just nine 20-min sessions of connected discourse tracking with the shifted simulation, performance improved significantly for the identification of intervocalic consonants, medial vowels in monosyllables, and words in sentences (30% of words). Also, listeners were able to track connected discourse of shifted signals without lipreading at rates up to 40 words per minute. Although we do not know if complete adaptation to the shifted signals is possible, it is clear that short-term experiments seriously exaggerate the long-term consequences of such spectral shifts.
The relative importance of fluid and kinetic frequency shifts of an electron plasma wave
NASA Astrophysics Data System (ADS)
Winjum, B. J.; Fahlen, J.; Mori, W. B.
2007-10-01
The total nonlinear frequency shift of a plasma wave including both fluid and kinetic effects is estimated when the phase velocity of the wave is much less than the speed of light. Using a waterbag or fluid model, the nonlinear frequency shift due to harmonic generation is calculated for an arbitrary shift in the wavenumber. In the limit where the wavenumber does not shift, the result is in agreement with previously published work [R. L. Dewar and J. Lindl, Phys. Fluids 15, 820 (1972); T. P. Coffey, Phys. Fluids 14, 1402 (1971)]. This shift is compared to the kinetic shift of Morales and O'Neil [G. J. Morales and T. M. O'Neil, Phys. Rev. Lett. 28, 417 (1972)] for wave amplitudes and values of kλD of interest to Raman backscatter of a laser driver in inertial confinement fusion.
Causes and occurrences of interruptions during ED triage.
Johnson, Kimberly D; Motavalli, Michele; Gray, Dean; Kuehn, Connie
2014-09-01
Interruptions have been shown to cause errors and delays in the treatment of emergency patients and pose a real threat during the triage process. Missteps during the triage assessment can send a patient down the wrong treatment path and lead to delays. The purpose of this project was to identify the types and frequency of interruptions during the ED triage interview process. A focus group of emergency nurses was organized to identify the types of interruptions that commonly occur during the triage interview. These interruptions would be validated through observations in triage. A tally sheet was developed and implemented to determine how often each interruption occurred during an 8-hour shift. Triage nurses completed the tally sheets while working the first shift (7 am to 3 pm). This shift was selected because patient intake in the US Department of Veterans Affairs Emergency Department is highest during this time. The categories of interruptions identified included provision of conveniences to visitors, coworker-related interruptions, patient care-related interruptions, locating of family members in the emergency department, and other miscellaneous interruptions. Tally sheets were completed by the triage nurses during 10 shifts. On average, triage nurses were interrupted 48.2 times during an 8-hour shift (7 interruptions per hour). After reviewing the data, we found that only 22% of interruptions were related to patient care. More frequently, the causes of interruptions were not related to patient care: opening the door (33%), providing conveniences to visitors (21%), waiting patients or family members asking "How much longer?" (14%), and other causes (10%). Frequent interruptions can interfere with concentration and may affect patient care. Non-patient care-related interruptions not only can be frustrating to the triage nurse but also can be offensive to triage patients; they ultimately delay care and may even affect the quality of care. However, because scarce research is available regarding interruptions during ED triage, the effects on patient outcomes are unclear. Additional research needs to be conducted to explore the causes and effects of interruptions to the triage process. Copyright © 2014 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.
Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting
Yun, S. H.; Tearney, G. J.; de Boer, J. F.; Bouma, B. E.
2009-01-01
A novel technique using an acousto-optic frequency shifter in optical frequency domain imaging (OFDI) is presented. The frequency shift eliminates the ambiguity between positive and negative differential delays, effectively doubling the interferometric ranging depth while avoiding image cross-talk. A signal processing algorithm is demonstrated to accommodate nonlinearity in the tuning slope of the wavelength-swept OFDI laser source. PMID:19484034
NASA Astrophysics Data System (ADS)
Jędrzejewska, Beata; Grabarz, Anna; Bartkowiak, Wojciech; Ośmiałowski, Borys
2018-06-01
The solvatochromism of the dyes was analyzed based on the four-parameter scale including: polarizability (SP), dipolarity (SdP), acidity (SA) and basicity (SB) parameters by method proposed by Catalán. The change of solvent to more polar caused the red shift of absorption and fluorescence band position. The frequency shifts manifest the change in the dipole moment upon excitation. The ground-state dipole moment of the difluoroboranyls was estimated based on changes in molecular polarization with temperature. Moreover, the Stokes shifts were used to calculate the excited state dipole moments of the dyes. For the calculation, the ground-state dipole moments and Onsager cavity radius were also determined theoretically using density functional theory (DFT). The experimentally determined excited-state dipole moments for the compounds are higher than the corresponding ground-state values. The increase in the dipole moment is described in terms of the nature of the excited state.
Yao, Zhongqi; Luo, Jie; Lai, Yun
2017-12-11
In this work, we propose that one-dimensional ultratransparent dielectric photonic crystals with wide-angle impedance matching and shifted elliptical equal frequency contours are promising candidate materials for illusion optics. The shift of the equal frequency contour does not affect the refractive behaviors, but enables a new degree of freedom in phase modulation. With such ultratransparent photonic crystals, we demonstrate some applications in illusion optics, including creating illusions of a different-sized scatterer and a shifted source with opposite phase. Such ultratransparent dielectric photonic crystals may establish a feasible platform for illusion optics devices at optical frequencies.
Frequency-Modulation Correlation Spectrometer
NASA Technical Reports Server (NTRS)
Margolis, J. S.; Martonchik, J. V.
1985-01-01
New type of correlation spectrometer eliminates need to shift between two cells, one empty and one containing reference gas. Electrooptical phase modulator sinusoidally shift frequencies of sample transmission spectrum.
Walker, Jennifer K M; Egger, Keith N; Henry, Gregory H R
2008-09-01
Arctic air temperatures are expected to rise significantly over the next century. Experimental warming of arctic tundra has been shown to increase plant productivity and cause community shifts and may also alter microbial community structure. Hence, the objective of this study was to determine whether experimental warming caused shifts in soil microbial communities by measuring changes in the frequency, relative abundance and/or richness of nosZ and nifH genotypes. Five sites at a high arctic coastal lowland were subjected to a 13-year warming experiment using open-top chambers (OTCs). Sites differed by dominant plant community, soil parent material and/or moisture regimen. Six soil cores were collected from each of four replicate OTC and ambient plots at each site and subdivided into upper and lower samples. Differences in frequency and relative abundance of terminal restriction fragments were assessed graphically by two-way cluster analysis and tested statistically with permutational multivariate analysis of variance (ANOVA). Genotypic richness was compared using factorial ANOVA. The genotype frequency, relative abundance and genotype richness of both nosZ and nifH communities differed significantly by site, and by OTC treatment and/or depth at some sites. The site that showed the most pronounced treatment effect was a wet sedge meadow, where community structure and genotype richness of both nosZ and nifH were significantly affected by warming. Although warming was an important factor affecting these communities at some sites at this high arctic lowland, overall, site factors were the main determinants of community structure.
NASA Astrophysics Data System (ADS)
Kakue, T.; Endo, Y.; Shimobaba, T.; Ito, T.
2014-11-01
We report frequency estimation of loudspeaker diaphragm vibrating at high speed by parallel phase-shifting digital holography which is a technique of single-shot phase-shifting interferometry. This technique records multiple phaseshifted holograms required for phase-shifting interferometry by using space-division multiplexing. We constructed a parallel phase-shifting digital holography system consisting of a high-speed polarization-imaging camera. This camera has a micro-polarizer array which selects four linear polarization axes for 2 × 2 pixels. We set a loudspeaker as an object, and recorded vibration of diaphragm of the loudspeaker by the constructed system. By the constructed system, we demonstrated observation of vibration displacement of loudspeaker diaphragm. In this paper, we aim to estimate vibration frequency of the loudspeaker diaphragm by applying the experimental results to frequency analysis. Holograms consisting of 128 × 128 pixels were recorded at a frame rate of 262,500 frames per second by the camera. A sinusoidal wave was input to the loudspeaker via a phone connector. We observed displacement of the loudspeaker diaphragm vibrating by the system. We also succeeded in estimating vibration frequency of the loudspeaker diaphragm by applying frequency analysis to the experimental results.
Hybrid Alfven resonant mode generation in the magnetosphere-ionosphere coupling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiraki, Yasutaka; Watanabe, Tomo-Hiko
2012-10-15
Feedback unstable Alfven waves involving global field-line oscillations and the ionospheric Alfven resonator (IAR) were comprehensively studied to clarify their properties of frequency dispersion, growth rate, and eigenfunctions. It is discovered that a new mode called here the hybrid Alfven resonant (HAR) mode can be destabilized in the magnetosphere-ionosphere coupling system with a realistic Alfven velocity profile. The HAR mode found in a high frequency range over 0.3 Hz is caused by coupling of IAR modes with strong dispersion and magnetospheric cavity resonances. The harmonic relation of HAR eigenfrequencies is characterized by a constant frequency shift from those of IARmore » modes. The three modes are robustly found even if effects of two-fluid process and ionospheric collision are taken into account and thus are anticipated to be detected by magnetic field observations in a frequency range of 0.3-1 Hz in auroral and polar-cap regions.« less
NASA Astrophysics Data System (ADS)
Chen, K. Y.; Su, S. Y.; Liu, C. H.; Basu, S.
2005-06-01
Quasiperiodic (QP) diffraction pattern in scintillation patches has been known to highly correlate with the edge structures of a plasma bubble (Franke et al., 1984). A new time-frequency analysis method of Hilbert-Huang transform (HHT) has been applied to analyze the scintillation data taken at Ascension Island to understand the characteristics of corresponding ionosphere irregularities. The HHT method enables us to extract the quasiperiodic diffraction signals embedded inside the scintillation data and to obtain the characteristics of such diffraction signals. The cross correlation of the two sets of diffraction signals received by two stations at each end of Ascension Island indicates that the density irregularity pattern that causes the diffraction pattern should have an eastward drift velocity of ˜130 m/s. The HHT analysis of the instantaneous frequency in the QP diffraction patterns also reveals some frequency shifts in their peak frequencies. For the QP diffraction pattern caused by the leading edge of the large density gradient at the east wall of a structured bubble, an ascending note in the peak frequency is observed, and for the trailing edge a descending note is observed. The linear change in the transient of the peak frequency in the QP diffraction pattern is consistent with the theory and the simulation result of Franke et al. Estimate of the slope in the transient frequency provides us the information that allows us to identify the locations of plasma walls, and the east-west scale of the irregularity can be estimated. In our case we obtain about 24 km in the east-west scale. Furthermore, the height location of density irregularities that cause the diffraction pattern is estimated to be between 310 and 330 km, that is, around the F peak during observation.
Atomic Clocks with Suppressed Blackbody Radiation Shift
NASA Astrophysics Data System (ADS)
Yudin, V. I.; Taichenachev, A. V.; Okhapkin, M. V.; Bagayev, S. N.; Tamm, Chr.; Peik, E.; Huntemann, N.; Mehlstäubler, T. E.; Riehle, F.
2011-07-01
We develop a concept of atomic clocks where the blackbody radiation shift and its fluctuations can be suppressed by 1-3 orders of magnitude independent of the environmental temperature. The suppression is based on the fact that in a system with two accessible clock transitions (with frequencies ν1 and ν2) which are exposed to the same thermal environment, there exists a “synthetic” frequency νsyn ∝ (ν1-ɛ12ν2) largely immune to the blackbody radiation shift. For example, in the case of Yb+171 it is possible to create a synthetic-frequency-based clock in which the fractional blackbody radiation shift can be suppressed to the level of 10-18 in a broad interval near room temperature (300±15K). We also propose a realization of our method with the use of an optical frequency comb generator stabilized to both frequencies ν1 and ν2, where the frequency νsyn is generated as one of the components of the comb spectrum.
Mass defect effects in atomic clocks
NASA Astrophysics Data System (ADS)
Yudin, Valeriy; Taichenachev, Alexey
2018-03-01
We consider some implications of the mass defect on the frequency of atomic transitions. We have found that some well-known frequency shifts (the gravitational shift and motion-induced shifts such as quadratic Doppler and micromotion shifts) can be interpreted as consequences of the mass defect in quantum atomic physics, i.e. without the need for the concept of time dilation used in special and general relativity theories. Moreover, we show that the inclusion of the mass defect leads to previously unknown shifts for clocks based on trapped ions.
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
NASA Astrophysics Data System (ADS)
Brown, R. C.; Phillips, N. B.; Beloy, K.; McGrew, W. F.; Schioppo, M.; Fasano, R. J.; Milani, G.; Zhang, X.; Hinkley, N.; Leopardi, H.; Yoon, T. H.; Nicolodi, D.; Fortier, T. M.; Ludlow, A. D.
2017-12-01
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an 171Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10-18 level and beyond.
Roller Bearing Health Monitoring Using CPLE Frequency Analysis Method
NASA Technical Reports Server (NTRS)
Jong, Jen-Yi; Jones, Jess H.
2007-01-01
This paper describes a unique vibration signature analysis technique Coherence Phase Line Enhancer (CPLE) Frequency Analysis - for roller bearing health monitoring. Defects of roller bearing (e.g. wear, foreign debris, crack in bearing supporting structure, etc.) can cause small bearing characteristic frequency shifts due to minor changes in bearing geometry. Such frequency shifts are often too small to detect by the conventional Power Spectral Density (PSD) due to its frequency bandwidth limitation. This Coherent Phase Line Enhancer technology has been evolving over the last few years and has culminated in the introduction of a new and novel frequency spectrum which is fully described in this paper. This CPLE technology uses a "key phasor" or speed probe as a preprocessor for this analysis. With the aid of this key phasor, this CPLE technology can develop a two dimensional frequency spectrum that preserves both amplitude and phase that is not normally obtained using conventional frequency analysis. This two-dimensional frequency transformation results in several newly defined spectral functions; i. e. CPLE-PSD, CPLE-Coherence and the CPLE-Frequency. This paper uses this CPLE frequency analysis to detect subtle, low level bearing related signals in the High Pressure Fuel Pump (HPFP) of the Space Shuttle Main Engine (SSME). For many rotating machinery applications, a key phasor is an essential measurement that is used in the detection of bearing related signatures. There are times however, when a key phasor is not available; i. e. during flight of any of the SSME turbopumps or on the SSME High Pressure Oxygen Turbopump (HPOTP) where no speed probe is present. In this case, the CPLE analysis approach can still be achieved using a novel Pseudo Key Phasor (PKP) technique to reconstruct a 1/Rev PKP signal directly from external vibration measurements. This paper develops this Pseudo Key Phasor technique and applies it to the SSME vibration data.
Safe and simple detection of sparse hydrogen by Pd-Au alloy/air based 1D photonic crystal sensor
NASA Astrophysics Data System (ADS)
Mitra, S.; Biswas, T.; Chattopadhyay, R.; Ghosh, J.; Bysakh, S.; Bhadra, S. K.
2016-11-01
A simple integrated hydrogen sensor using Pd-Au alloy/air based one dimensional photonic crystal with an air defect layer is theoretically modeled. Structural parameters of the photonic crystal are delicately scaled to generate photonic band gap frequencies in a visible spectral regime. An optimized defect thickness permits a localized defect mode operating at a frequency within the photonic band gap region. Hydrogen absorption causes modification in the band gap characteristics due to variation of refractive index and lattice parameters of the alloy. As a result, the transmission peak appeared due to the resonant defect state gets shifted. This peak shifting is utilized to detect sparse amount of hydrogen present in the surrounding environment. A theoretical framework is built to calculate the refractive index profile of hydrogen loaded alloy using density functional theory and Bruggeman's effective medium approximation. The calculated refractive index variation of Pd3Au alloy film due to hydrogen loading is verified experimentally by measuring the reflectance characteristics. Lattice expansion properties of the alloy are studied through X-ray diffraction analyses. The proposed structure shows about 3 nm red shift of the transmission peak for a rise of 1% atomic hydrogen concentration in the alloy.
NASA Technical Reports Server (NTRS)
Bahadur, H.; Parshad, R.
1981-01-01
The frequency behavior of AT-cut quartz crystals irradiated by X -, gamma rays and fast neutrons. Initial instability in frequency for gamma and neutron irradiated crystals was found. All the different radiations first give a negative frequency shift at lower doses which are followed by positive frequency shift for increased doses. Results are explained in terms of the fundamental crystal structure. Applications of the frequency results for radiation hardening are proposed.
Iwamoto, Reikichi; Kusanagi, Hiroshi
2009-05-07
This paper reports the structure of the hydrate complex of an isolated alcoholic OH, produced in a small amount in hydrophobic solution in heptane. The structure was determined from the changes, caused by hydration, in the infrared and near-infrared spectra of 2-nonanol in the solution. The changes were exhibited in the "difference" spectrum, in which the spectrum of the solution before hydration was subtracted from that after hydration. The difference spectrum showed a "plus" or "minus" peak at the frequency of the stretching band of a free OH, depending on whether the concentration was below or above about 2%(v/v), respectively. The plus peak appears because the OH stretching band of the isolated OH that acts as an acceptor does not change in frequency but significantly increases in intensity, in agreement with theoretical calculations. In contrast, the stretching band of an isolated OH that acts as a donor shifts downward. This shift decreases the intensity at the stretching frequency of a free OH, giving rise to a minus peak at the frequency in the difference spectrum. It was concluded that an isolated OH is hydrated in the manner as HO...HOH and OH...OH(2) at a concentration below and above about 2%, respectively, in the hydrophobic solution of 2-nonanol.
Reversal of orbital angular momentum arising from an extreme Doppler shift
Toninelli, Ermes; Horsley, Simon A. R.; Hendry, Euan; Phillips, David B.; Padgett, Miles J.
2018-01-01
The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes “negative.” In the linear case, this effect is associated with the time reversal of the received signal, but it can be observed only with supersonic relative motion between the source and receiver. However, the rotational case is different; if the radius of rotation is smaller than the wavelength, then the velocities required to observe negative frequencies are subsonic. Using an acoustic source at ≈100 Hz we create a rotational Doppler shift larger than the laboratory-frame frequency. We observe that once the red-shifted wave passes into the “negative frequency” regime, the angular momentum associated with the sound is reversed in sign compared with that of the laboratory frame. These low-velocity laboratory realizations of extreme Doppler shifts have relevance to superoscillatory fields and offer unique opportunities to probe interactions with rotating bodies and aspects of pseudorelativistic frame translation. PMID:29581257
Velocity Spectrum Variation in Central Gulf of Mexico: 9Case Studies for the 2005 Hurricanes
NASA Astrophysics Data System (ADS)
Zhang, F.; Li, C.
2012-12-01
Significant near inertial oscillation caused by hurricanes is common in the ocean. The details of the vertical and temporal variations of hurricane induced near inertial oscillation are usually complicated. We have done a case study of such vertical and temporal variations of velocity spectrum focusing around the inertial frequency for the 2005 hurricane season. Data were from a deep water mooring chain containing a series of current meters and 2 ADCPs from June to November 2005. The velocity spectrum is obtained with a 10-day sliding window at different depths for the 40-hour high-passed data to exclude the low frequency Loop Current variations. This gives a temporal variation of the spectrum at different depths. Such variations in velocity spectrum are resulted from the ocean dynamics influenced by the passage of hurricanes. Our preliminary analysis of the results show that (1) right before the center of the hurricane gets closest to the mooring site, there always exists a 2-peak feature of energy at almost all depths; while during the passage of the hurricane these two peaks will merge Into one peak which has a corresponding period of 30.3 to 25.6 hours, encompassing that corresponding to the inertial frequency in this latitude; (2) after the passage of the hurricane, the decay process of energy is also complicated. It is found that the whole profile can be at least divided into 3 layers: surface to 800m, 800m to 1500m, and 1500m to the bottom, which is consistent with the stratification of the water column. It is also found that shift in the peak frequency to either side of the inertial frequency is very common. The main peak of energy can break into several parts during the decay stage, with blue shift and red shift.; ;
Frequency shifts in distortion-product otoacoustic emissions evoked by swept tones
Shera, Christopher A.; Abdala, Carolina
2016-01-01
When distortion-product otoacoustic emissions (DPOAEs) are evoked using stimuli whose instantaneous frequencies change rapidly and continuously with time (swept tones), the oscillatory interference pattern known as distortion-product fine structure shifts slightly along the frequency axis in the same direction as the sweep. By analogy with the temporal mechanisms thought to underlie the differing efficacies of up- and down-swept stimuli as perceptual maskers (e.g., Schroeder-phase complexes), fine-structure shifts have been ascribed to the phase distortion associated with dispersive wave propagation in the cochlea. This paper tests an alternative hypothesis and finds that the observed shifts arise predominantly as a methodological side effect of the analysis procedures commonly used to extract delayed emissions from the measured time waveform. Approximate expressions for the frequency shifts of DPOAE distortion and reflection components are derived, validated with computer simulations, and applied to account for DPOAE fine-structure shifts measured in human subjects. Component magnitudes are shown to shift twice as much as component phases. Procedures for compensating swept-tone measurements to obtain estimates of the total DPOAE and its components measured at other sweep rates or in the sinusoidal steady state are presented. PMID:27586726
NASA Astrophysics Data System (ADS)
Lider, M. C.; Yurtseven, H.
2018-05-01
The resonant frequency shifts are related to the thermodynamic quantities (compressibility, order parameter and susceptibility) for the α-β transition in quartz. The experimental data for the resonant frequencies and the bulk modulus from the literature are used for those correlations. By calculating the order parameter from the mean field theory, correlation between the resonant frequencies of various modes and the order parameter is examined according to the quasi-harmonic phonon theory for the α-β transition in quartz. Also, correlation between the bulk modulus in relation to the resonant frequency shifts and the order parameter susceptibility is constructed for the α-β transition in this crystalline system.
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2014 CFR
2014-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
NASA Astrophysics Data System (ADS)
Sasaki, Yutaka; Meju, Max A.
2006-05-01
Accurate interpretation of magnetotelluric (MT) data in the presence of static shift arising from near-surface inhomogeneities is an unresolved problem in three-dimensional (3-D) inversion. While it is well known in 1-D and 2-D studies that static shift can lead to erroneous interpretation, how static shift can influence the result of 3-D inversion is not fully understood and is relevant to improved subsurface analysis. Using the synthetic data generated from 3-D models with randomly distributed heterogeneous overburden and elongate homogeneous overburden that are consistent with geological observations, this paper examines the effects of near-surface inhomogeneity on the accuracy of 3-D inversion models. It is found that small-scale and shallow depth structures are severely distorted while the large-scale structure is marginally distorted in 3-D inversion not accounting for static shift; thus the erroneous near-surface structure does degrade the reconstruction of smaller-scale structure at any depth. However, 3-D joint inversion for resistivity and static shift significantly reduces the artifacts caused by static shifts and improves the overall resolution, irrespective of whether a zero-sum or Gaussian distribution of static shifts is assumed. The 3-D joint inversion approach works equally well for situations where the shallow bodies are of small size or long enough to allow some induction such that the effects of near-surface inhomogeneity are manifested as a frequency-dependent shift rather than a constant shift.
The detection of brain oedema with frequency-dependent phase shift electromagnetic induction.
González, César A; Rubinsky, Boris
2006-06-01
The spectroscopic distribution of inductive phase shift in the brain as a function of the relative volume of oedema was evaluated with theoretical and experimental methods in the frequency range 1 to 8 MHz. The theoretical study employed a simple mathematical model of electromagnetic induction in tissue and brain tissue data available from the literature to calculate the phase shift as a function of oedema in the bulk of the brain. Experimental data were generated from bulk measurements of ex vivo homogenized pig brain tissue mixed with various volumes of physiological saline in a volume sample typical of the human brain. There is good agreement between the analytical and the experimental results. Detectable changes in phase shift begin from a frequency of about 3 MHz to 4 MHz in the tested compositions and volume. The phase shift increases with frequency and fluid content. The results suggest that measuring phase shift in the bulk of the brain has the potential for becoming a robust means for non-contact detection of oedema in the brain.
On the fog variability over south Asia
NASA Astrophysics Data System (ADS)
Syed, F. S.; Körnich, H.; Tjernström, M.
2012-12-01
An increasing trend in fog frequencies over south Asia during winter in the last few decades has resulted in large economical losses and has caused substantial difficulties in the daily lives of people. In order to better understand the fog phenomenon, we investigated the climatology, inter-annual variability and trends in the fog occurrence from 1976 to 2010 using observational data from 82 stations, well distributed over India and Pakistan. Fog blankets large area from Pakistan to Bangladesh across north India from west to east running almost parallel to south of the Himalayas. An EOF analysis revealed that the fog variability over the whole region is coupled and therefore must be governed by some large scale phenomenon on the inter-annual time scale. Significant positive trends were found in the fog frequency but this increase is not gradual, as with the humidity, but comprises of two distinct regimes shifts, in 1990 and 1998, with respect to both mean and variance. The fog is also detected in ERA-Interim 3 hourly, surface and model level forecast data when using the concept of "cross-over temperature" combined with boundary layer stability. This fog index is able to reproduce the regime shift around 1998 and shows that the method can be applied to analyze fog over south Asia. The inter-annual variability seems to be associated with the wave train originating from the North Atlantic in the upper troposphere that when causing higher pressure over the region results in an increased boundary layer stability and surface-near relative humidity. The trend and shifts in the fog occurrence seems to be associated with the gradual increasing trend in relative humidity from 1990 onwards.
Bloch-Siegert shift in an interacting Bose-Einstein condensate
NASA Astrophysics Data System (ADS)
Zhang, Jinyi; Eigen, Christoph; Lopes, Raphael; Garratt, Sam; Rousso, David; Smith, Robert P.; Hadzibabic, Zoran; Navon, Nir
2017-04-01
The Bloch-Siegert shift (BSS) is a paradigmatic frequency shift that arises from the nonlinear response of a two-level system (TLS) subjected to strong driving fields. When a TLS is driven by a linearly polarized field, the co-rotating-wave component leads to the famous Rabi oscillations. By contrast the co-rotating-wave component, whose role is usually neglected in a weak driving, leads to a frequency shift of the TLS resonance frequency. This phenomenon is encountered in various areas, from quantum optics to nuclear magnetic resonance.Here, we investigate the BSS in a box-trapped 87 Rb Bose-Einstein condensate (BEC) driven by a strong oscillating magnetic field gradient. By tuning the chemical potential of the gas, we investigate how the BSS evolves from the ideal shift of the two lowest energy levels of a single particle in a box to the unexplored shift of long-wavelength collective excitations of the interacting BEC.
Multiple-frequency continuous wave ultrasonic system for accurate distance measurement
NASA Astrophysics Data System (ADS)
Huang, C. F.; Young, M. S.; Li, Y. C.
1999-02-01
A highly accurate multiple-frequency continuous wave ultrasonic range-measuring system for use in air is described. The proposed system uses a method heretofore applied to radio frequency distance measurement but not to air-based ultrasonic systems. The method presented here is based upon the comparative phase shifts generated by three continuous ultrasonic waves of different but closely spaced frequencies. In the test embodiment to confirm concept feasibility, two low cost 40 kHz ultrasonic transducers are set face to face and used to transmit and receive ultrasound. Individual frequencies are transmitted serially, each generating its own phase shift. For any given frequency, the transmitter/receiver distance modulates the phase shift between the transmitted and received signals. Comparison of the phase shifts allows a highly accurate evaluation of target distance. A single-chip microcomputer-based multiple-frequency continuous wave generator and phase detector was designed to record and compute the phase shift information and the resulting distance, which is then sent to either a LCD or a PC. The PC is necessary only for calibration of the system, which can be run independently after calibration. Experiments were conducted to test the performance of the whole system. Experimentally, ranging accuracy was found to be within ±0.05 mm, with a range of over 1.5 m. The main advantages of this ultrasonic range measurement system are high resolution, low cost, narrow bandwidth requirements, and ease of implementation.
Spatial filtering velocimeter for vehicle navigation with extended measurement range
NASA Astrophysics Data System (ADS)
He, Xin; Zhou, Jian; Nie, Xiaoming; Long, Xingwu
2015-05-01
The idea of using spatial filtering velocimeter is proposed to provide accurate velocity information for vehicle autonomous navigation system. The presented spatial filtering velocimeter is based on a CMOS linear image sensor. The limited frame rate restricts high speed measurement of the vehicle. To extend measurement range of the velocimeter, a method of frequency shifting is put forward. Theoretical analysis shows that the frequency of output signal can be reduced and the measurement range can be doubled by this method when the shifting direction is set the same with that of image velocity. The approach of fast Fourier transform (FFT) is employed to obtain the power spectra of the spatially filtered signals. Because of limited frequency resolution of FFT, a frequency spectrum correction algorithm, called energy centrobaric correction, is used to improve the frequency resolution. The correction accuracy energy centrobaric correction is analyzed. Experiments are carried out to measure the moving surface of a conveyor belt. The experimental results show that the maximum measurable velocity is about 800deg/s without frequency shifting, 1600deg/s with frequency shifting, when the frame rate of the image is about 8117 Hz. Therefore, the measurement range is doubled by the method of frequency shifting. Furthermore, experiments were carried out to measure the vehicle velocity simultaneously using both the designed SFV and a laser Doppler velocimeter (LDV). The measurement results of the presented SFV are coincident with that of the LDV, but with bigger fluctuation. Therefore, it has the potential of application to vehicular autonomous navigation.
Long-Term Stability of NIST Chip-Scale Atomic Clock Physics Packages
2007-01-01
vacuum packaging), as has been demonstrated by Lutwak et al. [3]. Nevertheless, we tried to investigate the causes for the frequency shifts of...stability,” Optics Express, 13, 1249-1253. [3] R. Lutwak , J. Deng, W. Riley, M. Varghese, J. Leblanc, G. Tepolt, M. Mescher, D. K. Serkland, K. M. Geib...the 1st Annual Multiconference on Electronics and Photonics, 7-11 November 2006, Guanajuato, Mexico, in press. [6] R. Lutwak , P. Vlitas, M
Physical mechanism of coherent acoustic phonons generation and detection in GaAs semiconductor
NASA Astrophysics Data System (ADS)
Babilotte, P.; Morozov, E.; Ruello, P.; Mounier, D.; Edely, M.; Breteau, J.-M.; Bulou, A.; Gusev, V.
2007-12-01
We first describe the picosecond acoustic interferometry study of GaAs with two-colors pump-probe laser pulses. The dependence of the generation process on the pump wavelength and the detection process on the probe wavelength both can cause the shift in the phase of the Brillouin signal. Secondly, in order to distinguish the short high frequency wideband acoustic pulse from low frequency Brillouin contribution, we accomplished experiments with (100)GaAs semiconductor coated by a transparent and photoelastically inactive thin film, serving a delay line for the acoustic pulse. Even with highly penetrating pump light (approx 680nm), short acoustic disturbances of approx 7ps of duration have been registered.
NASA Astrophysics Data System (ADS)
Yang, Juan; Li, An Yong
2018-06-01
To study the hydrogen bonds upon photoexcited, the time dependent density function method (TD DFT) was performed to investigate the excited state hydrogen bond properties of between o-nitroaniline (ONA) and formaldehyde (CH2O). The optimized structures of the complex and the monomers both in the ground state and the electronically excited states are calculated using DFT and TD DFT method respectively. Quantum chemical calculations of the electronic and vibrational absorption spectra are also carried out by TD DFT method at the different level. The complex ONA⋯CH2O forms the intramolecular hydrogen bond and intermolecular hydrogen bonds. Since the strength of hydrogen bonds can be measured by studying the vibrational absorption spectra of the characteristic groups on the hydrogen bonding acceptor and donor, it evidently confirms that the hydrogen bonds is strengthened in the S1/S2/T1 excited states upon photoexcitation. As a result, the hydrogen bonds cause that the CH stretch frequency of the proton donor CH2O has a blue shift, and the electron excitations leads to a frequency red shift of Ndbnd O and Nsbnd H stretch modes in the o-nitroaniline(ONA) and a small frequency blue shift of CH stretch mode in the formaldehyde(CH2O) in the S1 and S2 excited states. The excited states S1, S2 and T1 are locally excited states where only the ONA moiety is excited, but the CH2O moiety remains in its ground state.
Constant frequency pulsed phase-locked loop measuring device
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Kushnick, Peter W. (Inventor); Cantrell, John H. (Inventor)
1993-01-01
A measuring apparatus is presented that uses a fixed frequency oscillator to measure small changes in the phase velocity ultrasonic sound when a sample is exposed to environmental changes such as changes in pressure, temperature, etc. The invention automatically balances electrical phase shifts against the acoustical phase shifts in order to obtain an accurate measurement of electrical phase shifts.
Behera, B; Das, Puspendu K
2018-05-10
Blue-shifting H-bonded (C-D···O) complexes between CDCl 3 and CH 3 HCO, (CH 3 ) 2 CO, and C 2 H 5 (CH 3 )CO, and red-shifting H-bonded (C-D···S) complexes between CDCl 3 with (CH 3 ) 2 S and (C 2 H 5 ) 2 S have been identified by Fourier transform infrared spectroscopy in the gas phase at room temperature. With increasing partial pressure of the components, a new band appears in the C-D stretching region of the vibrational spectra. The intensity of this band decreases with an increase in temperature at constant pressure, which provides the basis for identification of the H-bonded bands in the spectrum. The C-D stretching frequency of CDCl 3 is blue-shifted by +7.1, +4, and +3.2 cm -1 upon complexation with CH 3 HCO, (CH 3 ) 2 CO, and C 2 H 5 (CH 3 )CO, respectively, and red-shifted by -14 and -19.2 cm -1 upon complexation with (CH 3 ) 2 S and (C 2 H 5 ) 2 S, respectively. By using quantum chemical calculations at the MP2/6-311++G** level, we predict the geometry, electronic structural parameters, binding energy, and spectral shift of H-bonded complexes between CDCl 3 and two series of compounds named RCOR' (H 2 CO, CH 3 HCO, (CH 3 ) 2 CO, and C 2 H 5 (CH 3 )CO) and RSR' (H 2 S, CH 3 HS, (CH 3 ) 2 S, and (C 2 H 5 ) 2 S) series. The calculated and observed spectral shifts follow the same trends. With an increase in basicity of the H-bond acceptor, the C-D bond length increases, force constant decreases, and the frequency shifts to the red from the blue. The potential energy scans of the above complexes are done, which show that electrostatic attraction between electropositive D and electron-rich O/S causes bond elongation and red shift, and the electronic and nuclear repulsions lead to bond contraction and blue shifts. The dominance of the two opposing forces at the equilibrium geometry of the complex determines the nature of the shift, which changes both in magnitude and in direction with the basicity of the hydrogen-bond acceptor.
Roles of safety climate and shift work on perceived injury risk: a multi-level analysis.
Huang, Yueng-Hsiang; Chen, Jiu-Chiuan; DeArmond, Sarah; Cigularov, Konstantin; Chen, Peter Y
2007-11-01
This study evaluated the relationship between employees' work shift (i.e., day shift versus night shift) and perceptions of injury risk, and how the relationship is affected by company level safety climate and injury frequency. The results showed that night shift workers perceived a higher level of injury risk compared to day shift workers. Both company level safety climate and injury frequency played critical roles in predicting individual perceived work injury risk. Perception of injury risk of night shift workers was significantly lower when they perceived high-level rather than low-level safety climate. However, this pattern was not noticeable for day shift workers. These findings highlighted the importance of considering company level factors when attempting to understand the differences between day shift and night shift work on an individual's perception of injury risk.
Frequency-Shift Detectors Bind Binaural as Well as Monaural Frequency Representations
ERIC Educational Resources Information Center
Carcagno, Samuele; Semal, Catherine; Demany, Laurent
2011-01-01
Previous psychophysical work provided evidence for the existence of automatic frequency-shift detectors (FSDs) that establish perceptual links between successive sounds. In this study, we investigated the characteristics of the FSDs with respect to the binaural system. Listeners were presented with sound sequences consisting of a chord of pure…
NASA Astrophysics Data System (ADS)
Obayashi, Masayuki; Ishihara, Yasushi; Suetsugu, Daisuke
2017-03-01
We conducted synthetic experiments to evaluate the effects of shallow-layer reverberation in oceanic regions on P-wave travel times measured by waveform cross-correlation. Time shift due to waveform distortion by the reverberation was estimated as a function of period. Reverberations in the crystalline crust advance the P-waves by a frequency-independent time shift of about 0.3 s in oceans. Sediment does not affect the time shifts in the mid-ocean regions, but effects as large as -0.8 s or more occur where sediment thickness is greater than 600 m for periods longer than 15 s. The water layer causes time delays (+0.3 s) in the relatively shallow (<3500 m) water region for periods longer than 20 s. The time shift may influence mantle images obtained if the reverberation effects are not accounted for in seismic tomography. We propose a simple method to correct relative P-wave travel times at two sites for shallow-layer reverberation by the cross-convolution of the crustal responses at the two sites. [Figure not available: see fulltext. Caption: .
Cruz, Igor Cristino Silva; Meira, Verena Henschen; de Kikuchi, Ruy Kenji Papa; Creed, Joel Christopher
2016-04-01
Phase shift phenomena are becoming increasingly common. However, they are also opportunities to better understand how communities are structured. In Southwest Atlantic coral reefs, a shift to the zoanthid Palythoa cf. variabilis dominance has been described. To test if competition drove this process, we carried out a manipulative experiment with three coral species. To estimate the natural frequency of encounters we assess the relationship between the proportion of encounters and this zoanthids coverage. The contact causes necrosis in 78% of coral colonies (6.47 ± SD 7.92 cm(2)) in 118 days. We found a logarithmic relationship between the proportion of these encounters and the cover of P. cf. variabilis, where 5.5% coverage of this zoanthid is enough to put 50% of coral colonies in contact, increasing their partial mortality. We demonstrate that zoanthid coverage increase followed by coral mortality increase will reduce coral cover and that competition drives the phase shift process. Copyright © 2016 Elsevier Ltd. All rights reserved.
Graphene Squeeze-Film Pressure Sensors.
Dolleman, Robin J; Davidovikj, Dejan; Cartamil-Bueno, Santiago J; van der Zant, Herre S J; Steeneken, Peter G
2016-01-13
The operating principle of squeeze-film pressure sensors is based on the pressure dependence of a membrane's resonance frequency, caused by the compression of the surrounding gas which changes the resonator stiffness. To realize such sensors, not only strong and flexible membranes are required, but also minimization of the membrane's mass is essential to maximize responsivity. Here, we demonstrate the use of a few-layer graphene membrane as a squeeze-film pressure sensor. A clear pressure dependence of the membrane's resonant frequency is observed, with a frequency shift of 4 MHz between 8 and 1000 mbar. The sensor shows a reproducible response and no hysteresis. The measured responsivity of the device is 9000 Hz/mbar, which is a factor 45 higher than state-of-the-art MEMS-based squeeze-film pressure sensors while using a 25 times smaller membrane area.
Shear sensing based on a microstrip patch antenna
NASA Astrophysics Data System (ADS)
Mohammad, I.; Huang, H.
2012-10-01
A microstrip patch antenna sensor was studied for shear sensing with a targeted application of measuring plantar shear distribution on a diabetic foot. The antenna shear sensor consists of three components, namely an antenna patch, a soft foam substrate and a slotted ground plane. The resonant frequency of the antenna sensor is sensitive to the overlapping length between the slot in the ground plane and the antenna patch. A shear force applied along the direction of the slot deforms the foam substrate and causes a change in the overlapping length, which can be detected from the antenna frequency shift. The antenna shear sensor was designed based on simulated antenna frequency response and validated by experiments. Experimental results indicated that the antenna sensor exhibits high sensitivity to shear deformation and responds to the applied shear loads with excellent linearity and repeatability.
Wearable Contactless Respiration Sensor Based on Multi-Material Fibers Integrated into Textile.
Guay, Philippe; Gorgutsa, Stepan; LaRochelle, Sophie; Messaddeq, Younes
2017-05-06
In this paper, we report on a novel sensor for the contactless monitoring of the respiration rate, made from multi-material fibers arranged in the form of spiral antenna (2.45 GHz central frequency). High flexibility of the used composite metal-glass-polymer fibers permits their integration into a cotton t-shirt without compromising comfort or restricting movement of the user. At the same time, change of the antenna geometry, due to the chest expansion and the displacement of the air volume in the lungs, is found to cause a significant shift of the antenna operational frequency, thus allowing respiration detection. In contrast with many current solutions, respiration is detected without attachment of the electrodes of any kind to the user's body, neither direct contact of the fiber with the skin is required. Respiration patterns for two male volunteers were recorded with the help of a sensor prototype integrated into standard cotton t-shirt in sitting, standing, and lying scenarios. The typical measured frequency shift for the deep and shallow breathing was found to be in the range 120-200 MHz and 10-15 MHz, respectively. The same spiral fiber antenna is also shown to be suitable for short-range wireless communication, thus allowing respiration data transmission, for example, via the Bluetooth protocol, to mobile handheld devices.
Rapid jamming avoidance in biosonar.
Gillam, Erin H; Ulanovsky, Nachum; McCracken, Gary F
2007-03-07
The sonar systems of bats and dolphins are in many ways superior to man-made sonar and radar systems, and considerable effort has been devoted to understanding the signal-processing strategies underlying these capabilities. A major feature determining the efficiency of sonar systems is the sensitivity to noise and jamming signals. Previous studies indicated that echolocating bats may adjust their signal structure to avoid jamming ('jamming avoidance response'; JAR). However, these studies relied on behavioural correlations and not controlled experiments. Here, we provide the first experimental evidence for JAR in bats. We presented bats (Tadarida brasiliensis) with 'playback stimuli' consisting of recorded echolocation calls at one of six frequencies. The bats exhibited a JAR by shifting their call frequency away from the presented playback frequency. When the approaching bats were challenged by an abrupt change in the playback stimulus, they responded by shifting their call frequencies upwards, away from the playback. Interestingly, even bats initially calling below the playback's frequency shifted their frequencies upwards, 'jumping' over the playback frequency. These spectral shifts in the bats' calls occurred often within less than 200 ms, in the first echolocation call emitted after the stimulus switch-suggesting that rapid jamming avoidance is important for the bat.
Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts
Griffith, Jacob; Cluff, Kim; Eckerman, Brandon; Aldrich, Jessica; Becker, Ryan; Moore-Jansen, Peer; Patterson, Jeremy
2018-01-01
Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure. PMID:29596338
Nassiri, Parvin; Zare, Sajad; Monazzam, Mohammad R.; Pourbakht, Akram; Azam, Kamal; Golmohammadi, Taghi
2016-01-01
Introduction: Noise is considered as the most common cause of harmful physical effects in the workplace. A sound that is generated from within the inner ear is known as an otoacoustic emission (OAE). Distortion-product otoacoustic emissions (DPOAEs) assess evoked emission and hearing capacity. The aim of this study was to assess the signal-to-noise ratio in different frequencies and at different times of the shift work in workers exposed to various levels of noise. It was also aimed to provide a statistical model for signal-to-noise ratio (SNR) of OAEs in different frequencies based on the two variables of sound pressure level (SPL) and exposure time. Materials and Methods: This case–control study was conducted on 45 workers during autumn 2014. The workers were divided into three groups based on the level of noise exposure. The SNR was measured in frequencies of 1000, 2000, 3000, 4000, and 6000 Hz in both ears, and in three different time intervals during the shift work. According to the inclusion criterion, SNR of 6 dB or greater was included in the study. The analysis was performed using repeated measurements of analysis of variance, spearman correlation coefficient, and paired samples t-test. Results: The results showed that there was no statistically significant difference between the three exposed groups in terms of the mean values of SNR (P > 0.05). Only in signal pressure levels of 88 dBA with an interval time of 10:30–11:00 AM, there was a statistically significant difference between the right and left ears with the mean SNR values of 3000 frequency (P = 0.038). The SPL had a significant effect on the SNR in both the right and left ears (P = 0.023, P = 0.041). The effect of the duration of measurement on the SNR was statistically significant in both the right and left ears (P = 0.027, P < 0.001). Conclusion: The findings of this study demonstrated that after noise exposure during the shift, SNR of OAEs reduced from the beginning to the end of the shift. PMID:27991472
Development of high precision digital driver of acoustic-optical frequency shifter for ROG
NASA Astrophysics Data System (ADS)
Zhang, Rong; Kong, Mei; Xu, Yameng
2016-10-01
We develop a high precision digital driver of the acoustic-optical frequency shifter (AOFS) based on the parallel direct digital synthesizer (DDS) technology. We use an atomic clock as the phase-locked loop (PLL) reference clock, and the PLL is realized by a dual digital phase-locked loop. A DDS sampling clock up to 320 MHz with a frequency stability as low as 10-12 Hz is obtained. By constructing the RF signal measurement system, it is measured that the frequency output range of the AOFS-driver is 52-58 MHz, the center frequency of the band-pass filter is 55 MHz, the ripple in the band is less than 1 dB@3MHz, the single channel output power is up to 0.3 W, the frequency stability is 1 ppb (1 hour duration), and the frequency-shift precision is 0.1 Hz. The obtained frequency stability has two orders of improvement compared to that of the analog AOFS-drivers. For the designed binary frequency shift keying (2-FSK) and binary phase shift keying (2-PSK) modulation system, the demodulating frequency of the input TTL synchronous level signal is up to 10 kHz. The designed digital-bus coding/decoding system is compatible with many conventional digital bus protocols. It can interface with the ROG signal detecting software through the integrated drive electronics (IDE) and exchange data with the two DDS frequency-shift channels through the signal detecting software.
Novel insertion in exon 5 of the TCOF1 gene in twin sisters with Treacher Collins syndrome.
Marszałek-Kruk, Bożena Anna; Wójcicki, Piotr; Smigiel, Robert; Trzeciak, Wiesław H
2012-08-01
Treacher Collins syndrome (TCS) is associated with an abnormal differentiation of the first and second pharyngeal arches during fetal development. This causes mostly craniofacial deformities, which require numerous corrective surgeries. TCS is an autosomal dominant disorder and it occurs in the general population at a frequency of 1 in 50,000 live births. The syndrome is caused by mutations in the TCOF1 gene, which encodes the serine/alanine-rich protein named Treacle. Over 120 mutations of the TCOF1 gene responsible for TCS have been described. About 70% of recognized mutations are deletions, which lead to a frame shift, formation of a termination codon, and shortening of the protein product of the gene. Herewith, a new heterozygotic insertion, c.484_668ins185bp, was described in two monozygotic twin sisters suffering from TCS. This mutation was absent in their father, brother, and uncle, indicating a de novo origin. The insertion causes a shift in the reading frame and premature termination of translation at 167 aa. The novel insertion is the longest ever found in the TCOF1 gene and the only one found among monozygotic twin sisters.
Hertel, Moritz; Schmidt-Westhausen, Andrea Maria; Strietzel, Frank-Peter
2016-09-01
In order to identify oral candidiasis patients being at risk of carrying potentially drug-resistant Candida, the aim of the study was to detect local, systemic, demographic, and health-related factors influencing (I) yeast spectrum composition and (II) antifungal administration frequency. Additionally, the aim was to investigate (III) species shift occurrence. Data from 798 patients (496 females, 302 males; mean age 59.7) with oral candidiasis diagnosed based on positive clinical and microbial findings (species identification and CFU count) between 2006 and 2011 were retrospectively analyzed using Pearson's chi(2) test and regression analysis. Among 958 isolates, Candida albicans was the most frequently detected (76.8 %). Also, species intrinsically resistant to azoles were frequently isolated (15.8 and 17.7 % of isolates and patients). (I) Infections only caused by C. albicans were significantly associated with the use of inhalation steroids (p = 0.001) and antibiotics (p = 0.04), super-infection of lichen planus (p = 0.002), and the absence of removable dentures (p < 0.001). (II) Anti-mycotics were significantly more frequently administered in patients using inhalation steroids (p = 0.001), suffering from asthma/COPD, or smoking heavily (p = 0.003) and if C. albicans and non-albicans species were detected together (p = 0.001). (III) Pathogen composition did not change over time within the examined period (p = 0.239). Different variables enhance the presence of certain Candida and the antifungal prescription frequency. No species shift was evident. The major pathogen in oral candidiasis remains C. albicans. Nevertheless, therapeutic problems may be caused by the frequent presence of species intrinsically resistant to azoles, especially in patients wearing dentures.
The non-static effect of near-surface inhomogeneity on CSAMT data
NASA Astrophysics Data System (ADS)
Lei, Da; Fayemi, Busayo; Yang, Liangyong; Meng, Xiaohong
2017-04-01
Controlled source audio-frequency magnetotelluric (CSAMT) method has several advantages over magnetotelluric (MT) method, which includes the recording of lower noise signal and higher resolution data. However, CSAMT field data can still be distorted by the effect of near surface inhomogeneous body. It may be confused with static effect just like in MT, if three-dimensional subsurface geological body is buried under the receiver. Traditionally, the method used in static correction is adopted similar to that used in MT method for many years. In comparison, MT are the natural electric and magnetic fields in the frequency range of 0.0001 Hz to 500 Hz, while CSAMT fields are applied at frequencies ranging from 0.1 to 10 kHz. Hence, in this paper, the non-static effect of near-surface inhomogeneity in CSAMT was simulated through theoretical modeling and we summarized its characteristics. If the skin depth is much larger than the size of the near-surface inhomogeneous body that is close to the measurement point, the anomalous body causes a static effect which is represented by vertical shift in apparent resistivity curves for all frequencies from their expected values, but when the skin depth is much smaller than the size of the near-surface inhomogeneous body in the vicinity of the measurement point, the apparent resistivity curve at high frequencies remains unchanged, while at lower frequencies shift in value is observed. The near-surface effect may be confused with static effect in data processing; however, it cannot be corrected using previous static correction methods, but by using the two-dimensional inversion method. Hence, for such CSAMT data, both effective processing technique and inversion process is of great significance.
NASA Astrophysics Data System (ADS)
Hefferman, Gerald; Chen, Zhen; Wei, Tao
2017-07-01
This article details the generation of an extended-bandwidth frequency sweep using a single, communication grade distributed feedback (DFB) laser. The frequency sweep is generated using a two-step technique. In the first step, injection current modulation is employed as a means of varying the output frequency of a DFB laser over a bandwidth of 99.26 GHz. A digital optical phase lock loop is used to lock the frequency sweep speed during current modulation, resulting in a linear frequency chirp. In the second step, the temperature of the DFB laser is modulated, resulting in a shifted starting laser output frequency. A laser frequency chirp is again generated beginning at this shifted starting frequency, resulting in a frequency-shifted spectrum relative to the first recorded data. This process is then repeated across a range of starting temperatures, resulting in a series of partially overlapping, frequency-shifted spectra. These spectra are then aligned using cross-correlation and combined using averaging to form a single, broadband spectrum with a total bandwidth of 510.9 GHz. In order to investigate the utility of this technique, experimental testing was performed in which the approach was used as the swept-frequency source of a coherent optical frequency domain reflectometry system. This system was used to interrogate an optical fiber containing a 20 point, 1-mm pitch length fiber Bragg grating, corresponding to a period of 100 GHz. Using this technique, both the periodicity of the grating in the frequency domain and the individual reflector elements of the structure in the time domain were resolved, demonstrating the technique's potential as a method of extending the sweeping bandwidth of semiconductor lasers for frequency-based sensing applications.
Hefferman, Gerald; Chen, Zhen; Wei, Tao
2017-07-01
This article details the generation of an extended-bandwidth frequency sweep using a single, communication grade distributed feedback (DFB) laser. The frequency sweep is generated using a two-step technique. In the first step, injection current modulation is employed as a means of varying the output frequency of a DFB laser over a bandwidth of 99.26 GHz. A digital optical phase lock loop is used to lock the frequency sweep speed during current modulation, resulting in a linear frequency chirp. In the second step, the temperature of the DFB laser is modulated, resulting in a shifted starting laser output frequency. A laser frequency chirp is again generated beginning at this shifted starting frequency, resulting in a frequency-shifted spectrum relative to the first recorded data. This process is then repeated across a range of starting temperatures, resulting in a series of partially overlapping, frequency-shifted spectra. These spectra are then aligned using cross-correlation and combined using averaging to form a single, broadband spectrum with a total bandwidth of 510.9 GHz. In order to investigate the utility of this technique, experimental testing was performed in which the approach was used as the swept-frequency source of a coherent optical frequency domain reflectometry system. This system was used to interrogate an optical fiber containing a 20 point, 1-mm pitch length fiber Bragg grating, corresponding to a period of 100 GHz. Using this technique, both the periodicity of the grating in the frequency domain and the individual reflector elements of the structure in the time domain were resolved, demonstrating the technique's potential as a method of extending the sweeping bandwidth of semiconductor lasers for frequency-based sensing applications.
Cunningham, Charles H; Dominguez Viqueira, William; Hurd, Ralph E; Chen, Albert P
2014-02-01
Blip-reversed echo-planar imaging (EPI) is investigated as a method for measuring and correcting the spatial shifts that occur due to bulk frequency offsets in (13)C metabolic imaging in vivo. By reversing the k-space trajectory for every other time point, the direction of the spatial shift for a given frequency is reversed. Here, mutual information is used to find the 'best' alignment between images and thereby measure the frequency offset. Time-resolved 3D images of pyruvate/lactate/urea were acquired with 5 s temporal resolution over a 1 min duration in rats (N = 6). For each rat, a second injection was performed with the demodulation frequency purposely mis-set by +35 Hz, to test the correction for erroneous shifts in the images. Overall, the shift induced by the 35 Hz frequency offset was 5.9 ± 0.6 mm (mean ± standard deviation). This agrees well with the expected 5.7 mm shift based on the 2.02 ms delay between k-space lines (giving 30.9 Hz per pixel). The 0.6 mm standard deviation in the correction corresponds to a frequency-detection accuracy of 4 Hz. A method was presented for ensuring the spatial registration between (13)C metabolic images and conventional anatomical images when long echo-planar readouts are used. The frequency correction method was shown to have an accuracy of 4 Hz. Summing the spatially corrected frames gave a signal-to-noise ratio (SNR) improvement factor of 2 or greater, compared with the highest single frame. Copyright © 2013 John Wiley & Sons, Ltd.
Improvement in Rayleigh Scattering Measurement Accuracy
NASA Technical Reports Server (NTRS)
Fagan, Amy F.; Clem, Michelle M.; Elam, Kristie A.
2012-01-01
Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous velocity, density, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of an acousto-optic frequency shifting device to improve measurement accuracy in Rayleigh scattering experiments at the NASA Glenn Research Center. The frequency shifting device is used as a means of shifting the incident or reference laser frequency by 1100 MHz to avoid overlap of the Rayleigh and reference signal peaks in the interference pattern used to obtain the velocity, density, and temperature measurements, and also to calibrate the free spectral range of the Fabry-Perot etalon. The measurement accuracy improvement is evaluated by comparison of Rayleigh scattering measurements acquired with and without shifting of the reference signal frequency in a 10 mm diameter subsonic nozzle flow.
Apparatus and method for noninvasive particle detection using doppler spectroscopy
Sinha, Dipen N.
2016-05-31
An apparatus and method for noninvasively detecting the presence of solid particulate matter suspended in a fluid flowing through a pipe or an oil and gas wellbore are described. Fluid flowing through a conduit containing the particulate solids is exposed to a fixed frequency (>1 MHz) of ultrasonic vibrations from a transducer attached to the outside of the pipe. The returning Doppler frequency shifted signal derived from the scattering of sound from the moving solid particles is detected by an adjacent transducer. The transmitted signal and the Doppler signal are combined to provide sensitive particulate detection. The magnitude of the signal and the Doppler frequency shift are used to determine the particle size distribution and the velocity of the particles. Measurement of the phase shift between the applied frequency and the detected Doppler shifted may be used to determine the direction of motion of the particles.
On the Coriolis effect in acoustic waveguides.
Wegert, Henry; Reindl, Leonard M; Ruile, Werner; Mayer, Andreas P
2012-05-01
Rotation of an elastic medium gives rise to a shift of frequency of its acoustic modes, i.e., the time-period vibrations that exist in it. This frequency shift is investigated by applying perturbation theory in the regime of small ratios of the rotation velocity and the frequency of the acoustic mode. In an expansion of the relative frequency shift in powers of this ratio, upper bounds are derived for the first-order and the second-order terms. The derivation of the theoretical upper bounds of the first-order term is presented for linear vibration modes as well as for stable nonlinear vibrations with periodic time dependence that can be represented by a Fourier series.
NASA Technical Reports Server (NTRS)
Poulain, Pierre-Marie; Luther, Douglas S.; Patzert, William C.
1992-01-01
Two techniques were developed for estimating statistics of inertial oscillations from satellite-tracked drifters that overcome the difficulties inherent in estimating such statistics from data dependent upon space coordinates that are a function of time. Application of these techniques to tropical surface drifter data collected during the NORPAX, EPOCS, and TOGA programs reveals a latitude-dependent, statistically significant 'blue shift' of inertial wave frequency. The latitudinal dependence of the blue shift is similar to predictions based on 'global' internal-wave spectral models, with a superposition of frequency shifting due to modification of the effective local inertial frequency by the presence of strongly sheared zonal mean currents within 12 deg of the equator.
Nélisse, Hugues; Gaudreau, Marc-André; Boutin, Jérôme; Voix, Jérémie; Laville, Frédéric
2012-03-01
The effectiveness of hearing protection devices (HPDs), when used in workplace conditions, has been shown over the years to be usually lower than the labeled values obtained under well-controlled laboratory conditions. Causes for such discrepancies have been listed and discussed by many authors. This study is an attempt to understand the issues in greater details and quantify some of these factors by looking at the performance of hearing protectors as a function of time during full work shift conditions. A non-invasive field microphone in the real ear (F-MIRE)-based method has been developed for measuring the effectiveness of different HPDs as a function of time in the workplace. Details of the test procedures, the equipment used, and the post-processing operations are presented and discussed. The methodology was developed in such a way that a complete time and frequency representation are possible. The system was used on a total of 24 workers in eight different companies. Work shifts of up to 9-h long were recorded. Various types of earmuffs and one type of molded earplugs were tested. Attenuation data reported as a function of time showed, for most workers tested, considerable fluctuations over entire work shift periods. Parts of these fluctuations are attributed to variations in the low-frequency content in the noise (in particular for earmuffs) as well as poor insertion and/or fitting of earplugs. Lower performances than laboratory-based ones were once again observed for most cases tested but also, important left and right ear differences were obtained for many individuals. When reported as a function of frequency, the attenuation results suggested that the few approximations used to relate the measurements to subjective real-ear-attenuation-at-threshold (REAT) data were realistic. The use of individualized attenuation data and performance ratings for HPDs as well as a good knowledge of the ambient noise in the workplace are key ingredients when evaluating the performance of hearing protectors in field conditions.
2007-01-01
synchronization ; vm(k) white Gaussian noise with average power σ2. If the Doppler shift f m,k is significant, then it causes the received signal ym(k) to be time ...intersymbol interference (ISI) to extend over 20-300 symbols at a data rate of 2-10 kilosymbols per second. Another obstacle is the time -varying Doppler... synchronization that employs a phase-locked loop (PLL) or delay-locked loop (DLL). However, the DFE and PLL/DLL have to interact in a nonlinear fashion
Ground Runup Noise Suppression Program. Part 3. Dry Suppressor Technology Base.
1982-06-20
ref 7) used mineral wool to fill the bays. A facing of corrugated metal liner supports the mineral wool . During operation two types of problems...1978 52 tube. The hot jet velocity exhaust flow shifted/decinerated the mineral wool and caused the metal liner to crack/break off. Programs were...PREDICTED) 0 MINERAL WOOL FIBROUS LINER 315 630 1250 2500 5000 10000 20000 1/15 SCALE FREQUENCY Figure 2-30. Noise attenuation of liners in augmenter. K
Banno, Motohiro; Ohta, Kaoru; Yamaguchi, Sayuri; Hirai, Satori; Tominaga, Keisuke
2009-09-15
In aqueous solution, the basis of all living processes, hydrogen bonding exerts a powerful effect on chemical reactivity. The vibrational energy relaxation (VER) process in hydrogen-bonded complexes in solution is sensitive to the microscopic environment around the oscillator and to the geometrical configuration of the hydrogen-bonded complexes. In this Account, we describe the use of time-resolved infrared (IR) pump-probe spectroscopy to study the vibrational dynamics of (i) the carbonyl CO stretching modes in protic solvents and (ii) the OH stretching modes of phenol and carboxylic acid. In these cases, the carbonyl group acts as a hydrogen-bond acceptor, whereas the hydroxyl group acts as a hydrogen-bond donor. These vibrational modes have different properties depending on their respective chemical bonds, suggesting that hydrogen bonding may have different mechanisms and effects on the VER of the CO and OH modes than previously understood. The IR pump-probe signals of the CO stretching mode of 9-fluorenone and methyl acetate in alcohol, as well as that of acetic acid in water, include several components with different time constants. Quantum chemical calculations indicate that the dynamical components are the result of various hydrogen-bonded complexes that form between solute and solvent molecules. The acceleration of the VER is due to the increasing vibrational density of states caused by the formation of hydrogen bonds. The vibrational dynamics of the OH stretching mode in hydrogen-bonded complexes were studied in several systems. For phenol-base complexes, the decay time constant of the pump-probe signal decreases as the band peak of the IR absorption spectrum shifts to lower wavenumbers (the result of changing the proton acceptor). For phenol oligomers, the decay time constant of the pump-probe signal decreases as the probe wavenumber decreases. These observations show that the VER time strongly correlates with the strength of hydrogen bonding. This acceleration may be due to increased coupling between the OH stretching mode and the accepting mode of the VER, because the low-frequency shift caused by hydrogen bond formation is very large. Unlike phenol oligomers, however, the pump-probe signals of phenol-base complexes did not exhibit probe frequency dependence. For these complexes, rapid interconversion between different conformations causes rapid fluctuations in the vibrational frequency of the OH stretching modes, and these fluctuations level the VER times of different conformations. For the benzoic acid dimer, a quantum beat at a frequency of around 100 cm(-1) is superimposed on the pump-probe signal. This result indicates the presence of strong anharmonic coupling between the intramolecular OH stretching and the intermolecular stretching modes. From a two-dimensional plot of the OH stretching wavenumber and the low-frequency wavenumber, the wavenumber of the low-frequency mode is found to increase monotonically as the probe wavenumber is shifted toward lower wavenumbers. Our results represent a quantitative determination of the acceleration of VER by the formation of hydrogen bonds. Our studies merit further evaluation and raise fundamental questions about the current theory of vibrational dynamics in the condensed phase.
Genomic signals of selection predict climate-driven population declines in a migratory bird.
Bay, Rachael A; Harrigan, Ryan J; Underwood, Vinh Le; Gibbs, H Lisle; Smith, Thomas B; Ruegg, Kristen
2018-01-05
The ongoing loss of biodiversity caused by rapid climatic shifts requires accurate models for predicting species' responses. Despite evidence that evolutionary adaptation could mitigate climate change impacts, evolution is rarely integrated into predictive models. Integrating population genomics and environmental data, we identified genomic variation associated with climate across the breeding range of the migratory songbird, yellow warbler ( Setophaga petechia ). Populations requiring the greatest shifts in allele frequencies to keep pace with future climate change have experienced the largest population declines, suggesting that failure to adapt may have already negatively affected populations. Broadly, our study suggests that the integration of genomic adaptation can increase the accuracy of future species distribution models and ultimately guide more effective mitigation efforts. Copyright © 2018, American Association for the Advancement of Science.
NASA Astrophysics Data System (ADS)
Huang, S. S.; Huang, C. F.; Huang, K. N.; Young, M. S.
2002-10-01
A highly accurate binary frequency shift-keyed (BFSK) ultrasonic distance measurement system (UDMS) for use in isothermal air is described. This article presents an efficient algorithm which combines both the time-of-flight (TOF) method and the phase-shift method. The proposed method can obtain larger range measurement than the phase-shift method and also get higher accuracy compared with the TOF method. A single-chip microcomputer-based BFSK signal generator and phase detector was designed to record and compute the TOF, two phase shifts, and the resulting distance, which were then sent to either an LCD to display or a PC to calibrate. Experiments were done in air using BFSK with the frequencies of 40 and 41 kHz. Distance resolution of 0.05% of the wavelength corresponding to the frequency of 40 kHz was obtained. The range accuracy was found to be within ±0.05 mm at a range of over 6000 mm. The main advantages of this UDMS system are high resolution, low cost, narrow bandwidth requirement, and ease of implementation.
On the Confounding Effect of Temperature on Chemical Shift-Encoded Fat Quantification
Hernando, Diego; Sharma, Samir D.; Kramer, Harald; Reeder, Scott B.
2014-01-01
Purpose To characterize the confounding effect of temperature on chemical shift-encoded (CSE) fat quantification. Methods The proton resonance frequency of water, unlike triglycerides, depends on temperature. This leads to a temperature dependence of the spectral models of fat (relative to water) that are commonly used by CSE-MRI methods. Simulation analysis was performed for 1.5 Tesla CSE fat–water signals at various temperatures and echo time combinations. Oil–water phantoms were constructed and scanned at temperatures between 0 and 40°C using spectroscopy and CSE imaging at three echo time combinations. An explanted human liver, rejected for transplantation due to steatosis, was scanned using spectroscopy and CSE imaging. Fat–water reconstructions were performed using four different techniques: magnitude and complex fitting, with standard or temperature-corrected signal modeling. Results In all experiments, magnitude fitting with standard signal modeling resulted in large fat quantification errors. Errors were largest for echo time combinations near TEinit ≈ 1.3 ms, ΔTE ≈ 2.2 ms. Errors in fat quantification caused by temperature-related frequency shifts were smaller with complex fitting, and were avoided using a temperature-corrected signal model. Conclusion Temperature is a confounding factor for fat quantification. If not accounted for, it can result in large errors in fat quantifications in phantom and ex vivo acquisitions. PMID:24123362
A Micro-Resonant Gas Sensor with Nanometer Clearance between the Pole Plates
Xu, Lizhong
2018-01-01
In micro-resonant gas sensors, the capacitive detection is widely used because of its simple structure. However, its shortcoming is a weak signal output caused by a small capacitance change. Here, we reduced the initial clearance between the pole plates to the nanometer level, and increased the capacitance between the pole plates and its change during resonator vibration. We propose a fabricating process of the micro-resonant gas sensor by which the initial clearance between the pole plates is reduced to the nanometer level and a micro-resonant gas sensor with 200 nm initial clearance is fabricated. With this sensor, the resonant frequency shifts were measured when they were exposed to several different vapors, and high detection accuracies were obtained. The detection accuracy with respect to ethanol vapor was 0.4 ppm per Hz shift, and the detection accuracy with respect to hydrogen and ammonias vapors was 3 ppm and 0.5 ppm per Hz shift, respectively. PMID:29373546
A Micro-Resonant Gas Sensor with Nanometer Clearance between the Pole Plates.
Fu, Xiaorui; Xu, Lizhong
2018-01-26
In micro-resonant gas sensors, the capacitive detection is widely used because of its simple structure. However, its shortcoming is a weak signal output caused by a small capacitance change. Here, we reduced the initial clearance between the pole plates to the nanometer level, and increased the capacitance between the pole plates and its change during resonator vibration. We propose a fabricating process of the micro-resonant gas sensor by which the initial clearance between the pole plates is reduced to the nanometer level and a micro-resonant gas sensor with 200 nm initial clearance is fabricated. With this sensor, the resonant frequency shifts were measured when they were exposed to several different vapors, and high detection accuracies were obtained. The detection accuracy with respect to ethanol vapor was 0.4 ppm per Hz shift, and the detection accuracy with respect to hydrogen and ammonias vapors was 3 ppm and 0.5 ppm per Hz shift, respectively.
Raman shifts in electron-irradiated monolayer MoS 2
Parkin, William M.; Balan, Adrian; Liang, Liangbo; ...
2016-03-21
Here, we report how the presence of electron-beam-induced sulfur vacancies affects first-order Raman modes and correlate the effects with the evolution of the in situ transmission-electron microscopy (TEM) two-terminal conductivity of monolayer MoS 2 under electron irradiation. We observe a redshift in the E Raman peak and a less pronounced blueshift in the A' 1 peak with increasing electron dose. Using energy-dispersive X-ray spectroscopy (EDS), we show that irradiation causes partial removal of sulfur and correlate the dependence of the Raman peak shifts with S vacancy density (a few %), which is confirmed by first-principles density functional theory calculations. Inmore » situ device current measurements show exponential decrease in channel current upon irradiation. Our analysis demonstrates that the observed frequency shifts are intrinsic properties of the defective systems and that Raman spectroscopy can be used as a quantitative diagnostic tool to characterize MoS 2-based transport channels.« less
NASA Astrophysics Data System (ADS)
Su, Junwei
Dropwise condensation (DWC) on hydrophobic surfaces is attracting attention for its great potential in many industrial applications, such as steam power plants, water desalination, and de-icing of aerodynamic surfaces, to list a few. The direct dynamic characterization of liquid/solid interaction can significantly accelerate the progress toward a full understanding of the thermal and mass transport mechanisms during DWC processes. The research focuses on the development of a novel acoustic-based technique for analyzing the liquid/solid interactions of different condensations on micro- and nanostructured surfaces including DWC. hi addition. the newly developed technology was demonstrated for quantitatively sensing different wetting states of liquid on rough surfaces. First, different micro/nanostructures were fabricated on the quartz crystal microbalance (QCM), which serves as acoustic sensor. Polymethyl methacrylate (PMMA) micropillars, with varying heights from 6.03 to 25.02 microm, were fabricated on a quartz crystal microbalance (QCM) substrate by thermal nanoimprinting lithography to form pillar-based QCM (QCM-P). For nanostructured QCM. a copper layer was deposited on the QCM surface and then nanostructures of copper oxide (CuO) films were formed via chemical oxidation in an alkaline solution. Then, these surfaces were treated to make them superhydrophilic or superhydrophobic using oxygen plasma treatment or with coating of 1H,1 H,2H,2H-perfluorooctyl-trichlorosilane (PFOTS). Based on the geometry of these micro/nanostructures, the relationship between the frequency responses of QCM and the wetting states of these surfaces was theoretically investigated. Different theoretical models were established to describing the frequency shift of the micro- and nanostructured QCM in different wetting states. For the microstructured surface, the cantilever based model and a two-degree-of-freedom dynamic model were applied to predict the frequency shift of the QCM-P in different wetting states, by taking advantage of the well-defined micropillar structures. For the nanostructured surface, the gravimetric term was applied for the penetrated liquid as it moves synchronously with the oscillating crystal surface. It was revealed that the penetrated wetting state (Wenzel state) causes one order of magnitude higher frequency shift of the QCM than the suspended state (Cassie state) does. For the suspended state, the equivalent liquid mass on the tips of the roughness dominates the frequency shift signal instead of the damping. A nonlinear relationship appears between the frequency shift and micropillar height for both Cassie and Wenzel wetting states, due to the vibration phase veering at the "critical height". This implied that a significant improvement of sensitivity of QCM-P over traditional QCM occurred in the suspended state, as well as in the penetrated state. Besides, the suspended state provides a much higher quality factor than penetrated state. Using the insights gained from the experimental results and modeling results, the frequency shift of the QCM was normalized to reveal the wetting state directly. Then. the QCM device together with the microscopic observation was used to probe the droplets' growth and their coalescence processes. The normalized frequency shifts of QCM devices are clearly linked to the different condensation states at a global level, which cannot be characterized by other techniques such as E-SEM and TEM. The characterization of the trapped liquid in micro/nanostructures, which is very challenging for microscopic observation, can be easily carried out by this acoustic technique. These results quantitatively demonstrated the different condensation states. In addition, the transition between the Cassie and the Wenzel states was successfully captured by this method. The newly developed QCM system provides a valuable tool for the dynamic characterization of different condensation processes.
Karplus, H.H.B.; Raptis, A.C.
1981-11-13
A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.
Karplus, Henry H. B.; Raptis, Apostolos C.
1983-01-01
A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.
NASA Technical Reports Server (NTRS)
Bigger, J. T. Jr; Steinman, R. C.; Rolnitzky, L. M.; Fleiss, J. L.; Albrecht, P.; Cohen, R. J.
1996-01-01
BACKGROUND. The purposes of the present study were (1) to establish normal values for the regression of log(power) on log(frequency) for, RR-interval fluctuations in healthy middle-aged persons, (2) to determine the effects of myocardial infarction on the regression of log(power) on log(frequency), (3) to determine the effect of cardiac denervation on the regression of log(power) on log(frequency), and (4) to assess the ability of power law regression parameters to predict death after myocardial infarction. METHODS AND RESULTS. We studied three groups: (1) 715 patients with recent myocardial infarction; (2) 274 healthy persons age and sex matched to the infarct sample; and (3) 19 patients with heart transplants. Twenty-four-hour RR-interval power spectra were computed using fast Fourier transforms and log(power) was regressed on log(frequency) between 10(-4) and 10(-2) Hz. There was a power law relation between log(power) and log(frequency). That is, the function described a descending straight line that had a slope of approximately -1 in healthy subjects. For the myocardial infarction group, the regression line for log(power) on log(frequency) was shifted downward and had a steeper negative slope (-1.15). The transplant (denervated) group showed a larger downward shift in the regression line and a much steeper negative slope (-2.08). The correlation between traditional power spectral bands and slope was weak, and that with log(power) at 10(-4) Hz was only moderate. Slope and log(power) at 10(-4) Hz were used to predict mortality and were compared with the predictive value of traditional power spectral bands. Slope and log(power) at 10(-4) Hz were excellent predictors of all-cause mortality or arrhythmic death. To optimize the prediction of death, we calculated a log(power) intercept that was uncorrelated with the slope of the power law regression line. We found that the combination of slope and zero-correlation log(power) was an outstanding predictor, with a relative risk of > 10, and was better than any combination of the traditional power spectral bands. The combination of slope and log(power) at 10(-4) Hz also was an excellent predictor of death after myocardial infarction. CONCLUSIONS. Myocardial infarction or denervation of the heart causes a steeper slope and decreased height of the power law regression relation between log(power) and log(frequency) of RR-interval fluctuations. Individually and, especially, combined, the power law regression parameters are excellent predictors of death of any cause or arrhythmic death and predict these outcomes better than the traditional power spectral bands.
Digital phase shifter synchronizes local oscillators
NASA Technical Reports Server (NTRS)
Ali, S. M.
1978-01-01
Digital phase-shifting network is used as synchronous frequency multiplier for applications such as phase-locking two signals that may differ in frequency. Circuit has various phase-shift capability. Possible applications include data-communication systems and hybrid digital/analog phase-locked loops.
A binaural beat constructed from a noise
Akeroyd, Michael A
2012-01-01
The binaural beat has been used for over one hundred years as a stimulus for generating the percept of motion. Classically the beat consists of a pure tone at one ear (e.g. 500 Hz) and the same pure tone at the other ear but shifted upwards or downwards in frequency (e.g., 501 Hz). An experiment and binaural computational analysis are reported which demonstrate that a more powerful motion percept can be obtained by applying the concept of the frequency shift to a noise, via an upwards or downwards shift in the frequency of the Fourier components of its spectrum. PMID:21218863
Continuous wave operation of quantum cascade lasers with frequency-shifted feedback
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyakh, A., E-mail: arkadiy.lyakh@ucf.edu; NanoScience Technology Center, University of Central Florida, 12424 Research Pkwy, Orlando, FL 32826; College of Optics and Photonics, University of Central Florida, 304 Scorpius St, Orlando, FL 32826
2016-01-15
Operation of continuous wave quantum cascade lasers with a frequency-shifted feedback provided by an acousto-optic modulator is reported. Measured linewidth of 1.7 cm{sup −1} for these devices, under CW operating conditions, was in a good agreement with predictions of a model based on frequency-shifted feedback seeded by spontaneous emission. Linewidth broadening was observed for short sweep times, consistent with sound wave grating period variation across the illuminated area on the acousto-optic modulator. Standoff detection capability of the AOM-based QCL setup was demonstrated for several solid materials.
Tunable metamaterial dual-band terahertz absorber
NASA Astrophysics Data System (ADS)
Luo, C. Y.; Li, Z. Z.; Guo, Z. H.; Yue, J.; Luo, Q.; Yao, G.; Ji, J.; Rao, Y. K.; Li, R. K.; Li, D.; Wang, H. X.; Yao, J. Q.; Ling, F. R.
2015-11-01
We report a design of a temperature controlled tunable dual band terahertz absorber. The compact single unit cell consists of two nested closed square ring resonators and a layer metallic separated by a substrate strontium titanate (STO) dielectric layer. It is found that the absorber has two distinctive absorption peaks at frequencies 0.096 THz and 0.137 THz, whose peaks are attained 97% and 75%. Cooling the absorber from 400 K to 250 K causes about 25% and 27% shift compared to the resonance frequency of room temperature, when we cooling the temperature to 150 K, we could attained both the two tunabilities exceeding 53%. The frequency tunability is owing to the variation of the dielectric constant of the low-temperature co-fired ceramic (LTCC) substrate. The mechanism of the dual band absorber is attributed to the overlapping of dual resonance frequencies, and could be demonstrated by the distributions of the electric field. The method opens up avenues for designing tunable terahertz devices in detection, imaging, and stealth technology.
Optimal frequency-response sensitivity of compressible flow over roughness elements
NASA Astrophysics Data System (ADS)
Fosas de Pando, Miguel; Schmid, Peter J.
2017-04-01
Compressible flow over a flat plate with two localised and well-separated roughness elements is analysed by global frequency-response analysis. This analysis reveals a sustained feedback loop consisting of a convectively unstable shear-layer instability, triggered at the upstream roughness, and an upstream-propagating acoustic wave, originating at the downstream roughness and regenerating the shear-layer instability at the upstream protrusion. A typical multi-peaked frequency response is recovered from the numerical simulations. In addition, the optimal forcing and response clearly extract the components of this feedback loop and isolate flow regions of pronounced sensitivity and amplification. An efficient parametric-sensitivity framework is introduced and applied to the reference case which shows that first-order increases in Reynolds number and roughness height act destabilising on the flow, while changes in Mach number or roughness separation cause corresponding shifts in the peak frequencies. This information is gained with negligible effort beyond the reference case and can easily be applied to more complex flows.
NASA Astrophysics Data System (ADS)
Falocchi, Marco; Giovannini, Lorenzo; Franceschi, Massimiliano de; Zardi, Dino
2018-05-01
We present a refinement of the recursive digital filter proposed by McMillen (Boundary-Layer Meteorol 43:231-245, 1988), for separating surface-layer turbulence from low-frequency fluctuations affecting the mean flow, especially over complex terrain. In fact, a straightforward application of the filter causes both an amplitude attenuation and a forward phase shift in the filtered signal. As a consequence turbulence fluctuations, evaluated as the difference between the original series and the filtered one, as well as higher-order moments calculated from them, may be affected by serious inaccuracies. The new algorithm (i) produces a rigorous zero-phase filter, (ii) restores the amplitude of the low-frequency signal, and (iii) corrects all filter-induced signal distortions.
FIBER AND INTEGRATED OPTICS: Multiplexed optical-fiber sensors with autodyne detection
NASA Astrophysics Data System (ADS)
Potapov, V. T.; Mamedov, A. M.; Shatalin, S. V.; Yushkaĭtis, R. V.
1993-09-01
A method is proposed for multiplexing optical-fiber interference sensors. The method involves autodyne reception of frequency-modulated radiation reflected back to the laser. The response of a He-Ne laser with a linearly varying generation frequency to radiation reflected back from a single-mode fiber is studied. The spectrum of beats caused in the laser radiation by the reflection is shown to be governed by the distribution of reflectors along the fiber. The phases of the spectral components contain information about the phase shift of the reflected optical signal. A hydrophone array with a sensitivity of 30 μrad/Hz1/2 is described. A distributed temperature sensor with a spatial resolution of 1 m is also described.
NASA Technical Reports Server (NTRS)
Bao, H.; Kwatra, S. C.; Kim, Junghwan; Stevens, G. H.
1990-01-01
A spread spectrum system, slow frequency hopping with GMSK (Gaussian minimum shift keying) modulation (SFH-GMSK), is proposed for mobile telephone communications. The system performance is evaluated using computer simulation and is compared with an unspread system. Results show that under multipath fading conditions, when the signal-to-noise ratio (SNR) is greater than 15 dB, slow frequency hopping gives some bit error rate improvement over the unspread system. Theoretical predictions indicate that a system efficiency of 20-65 users per cell can be achieved in the cellular configuration. Joint use of SFH-GMSK and FM is also investigated. It is shown that FM interference can cause serious degradation to the SFH-GMSK performance.
High-frequency tone burst-evoked ABR latency-intensity functions.
Fausti, S A; Olson, D J; Frey, R H; Henry, J A; Schaffer, H I
1993-01-01
High-frequency tone burst stimuli (8, 10, 12, and 14 kHz) have been developed and demonstrated to provide reliable and valid auditory brainstem responses (ABRs) in normal-hearing subjects. In this study, latency-intensity functions (LIFs) were determined using these stimuli in 14 normal-hearing individuals. Significant shifts in response latency occurred as a function of stimulus intensity for all tone burst frequencies. For each 10 dB shift in intensity, latency shifts for waves I and V were statistically significant except for one isolated instance. LIF slopes were comparable between frequencies, ranging from 0.020 to 0.030 msec/dB. These normal LIFs for high-frequency tone burst-evoked ABRs suggest the degree of response latency change that might be expected from, for example, progressive hearing loss due to ototoxic insult, although these phenomena may not be directly related.
Yuantai Hu; Huiliang Hu; Bin Luo; Huan Xue; Jiemin Xie; Ji Wang
2013-08-01
A two-dimensional model was established to study the dynamic characteristics of a quartz crystal resonator with the upper surface covered by an array of hemispherical material units. A frequency-dependent equivalent mass ratio was proposed to simulate the effect of the covered units on frequency shift of the resonator system. It was found that the equivalent mass ratio alternately becomes positive or negative with change of shear modulus and radius of each material unit, which indicates that the equivalent mass ratio is strongly related to the vibration mode of the covered loadings. The further numerical results show the cyclical feature in the relationship of frequency shift and shear modulus/radius as expected. The solutions are useful in the analysis of frequency stability of quartz resonators and acoustic wave sensors.
Coverage dependent non-adiabaticity of CO on a copper surface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omiya, Takuma; Surface and Interface Science Laboratory, RIKEN, Wako 351-0198; Arnolds, Heike
2014-12-07
We have studied the coverage-dependent energy transfer dynamics between hot electrons and CO on Cu(110) with femtosecond visible pump, sum frequency probe spectroscopy. We find that transients of the C–O stretch frequency display a red shift, which increases from 3 cm{sup −1} at 0.1 ML to 9 cm{sup −1} at 0.77 ML. Analysis of the transients reveals that the non-adiabatic coupling between the adsorbate vibrational motion and the electrons becomes stronger with increasing coverage. This trend requires the frustrated rotational mode to be the cause of the non-adiabatic behavior, even for relatively weak laser excitation of the adsorbate. We attributemore » the coverage dependence to both an increase in the adsorbate electronic density of states and an increasingly anharmonic potential energy surface caused by repulsive interactions between neighboring CO adsorbates. This work thus reveals adsorbate-adsorbate interactions as a new way to control adsorbate non-adiabaticity.« less
McCamant, David W
2011-07-28
This work presents a theoretical treatment of the vibrational line shape generated in a femtosecond stimulated Raman spectroscopy (FSRS) experiment under conditions in which the probed vibration undergoes a significant frequency shift during its free induction decay. This theory is applied to simulate the FSRS lineshapes previously observed in rhodopsin (Kukura et al. Science 2005, 310, 1006). The previously determined relaxation times for formation of the trans-photoproduct of rhodopsin were calculated using an incorrect equation for the time dependence of the observed frequency shifts. Here the data are reanalyzed by calculation of the corrected frequency sweep occurring during the vibrational free induction decay. It is shown that the calculated frequency shifts and general conclusions of the original work are sound but that the coherent vibrational frequency shifts of the C(10), C(11), and C(12) hydrogen-out-of-plane vibrations occur with a 140 fs time constant rather than the previously reported 325 fs time constant. This time constant provides an important constraint for models of the dynamics of the cis to trans isomerization process. © 2011 American Chemical Society
Improved equivalent circuit for twin slot terahertz receivers
NASA Technical Reports Server (NTRS)
McGrath, W. R.
2002-01-01
Series-fed coplanar waveguide embedding circuits are being developed for terahertz mixers using, in particular, submicron-sized superconducting devices, such as hot electron bolometers as the nonlinear element. Although these mixers show promising performance, they usually also show a considerable downward shift in the center frequency, when compared with simulations obtained by using simplified models. This makes it very difficult to design low-noise mixers for a given THz frequency. This shiftis principally caused by parasitics due to the extremely small details (in terms of wavelength) of the device, and by the electrical properties of the RF choke filter in the DC/IF line. In this paper, we present an improved equivalent network model of such mixer circuits which agrees with measured results at THz frequencies and we propose a new set of THz bolometric mixers that have been fabricated and are currently being tested.
NASA Astrophysics Data System (ADS)
Yoon, Jong Rak; Park, Kyu-Chil; Park, Jihyun
2015-07-01
Transmitted signals are markedly affected by sea surface and bottom boundaries in shallow water. The time variant reflection signals from such boundaries characterize the channel as a frequency-selective fading channel and cause intersymbol interference (ISI) in underwater acoustic communication. A channel-estimate-based equalizer is usually adopted to compensate for the reflected signals under this kind of acoustic channel. In this study, we apply two approaches for packet and continuous data transmission of the quadrature phase shift keying (QPSK) system. One is the use of a two-dimensional (2D) rotation matrix in a non-frequency-selective channel. The other is the use of two equalizers of types — the feed forward equalizer (FFE) and decision-directed equalizer (DDE) — with a normalized least mean square (NLMS) algorithm in a frequency-selective channel. The percentage improvement of packet transmission is notably better than that of continuous transmission.
NASA Technical Reports Server (NTRS)
Ancellet, G. M.; Menzies, R. T.; Brothers, A. M.
1987-01-01
Longitudinal mode selection by injection has been demonstrated as a viable technique for TEA-CO2 lasers with pulse energies of a Joule or greater. Once reliable generation of single-longitudinal-mode (SLM) pulses is obtained, the characteristics and the causes of intrapulse frequency variation can be studied. These include the effect of the decaying plasma, the thermal gradient due to the energy dissipation associated with the laser mechanism itself, and the pressure shift of the center frequency of the laser transition. The use of the positive-branch unstable resonator as an efficient means of coupling a discharge with large spatial dimensions to an optical cavity mode introduces another concern: namely, what can be done to emphasize transverse mode discrimination in an unstable resonator cavity while maintaining high coupling efficiency. These issues are discussed in this paper, and relevant experimental results are included.
Dielectric relaxation in Li2SO4 in the intermedia-temperature regime
NASA Astrophysics Data System (ADS)
Diosa, J. E.; Vargas, R. A.; Fernández, M. E.; Albinsson, I.; Mellander, B.-E.
2005-08-01
The dielectric permittivity of polycrystalline Li2SO4 was measured from 5 Hz to 13 MHz and over the temperature range 235-460 °C. The corrected imaginary part of permittivity, , and its real part vs. frequency clearly show a new dielectric relaxation around fmax = 2 × 104 Hz at T = 256 °C, which shifts to higher frequencies (1 MHz) as the temperatures increases. The relaxation frequency (calculated from the peak position of ) vs. reciprocal T shows an activated relaxation process with activation energy Ea= 0.9 eV, which is very close to that derived from the dc conductivity, E (0.87 eV). We suggest that this dielectric relaxation could be due to the Li+ jump and SO4- reorientation that cause distortion and change of the local lattice polarizability inducing dipoles like LiSO4-.
Hyper-Ramsey spectroscopy of optical clock transitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yudin, V. I.; Taichenachev, A. V.; Oates, C. W.
2010-07-15
We present nonstandard optical Ramsey schemes that use pulses individually tailored in duration, phase, and frequency to cancel spurious frequency shifts related to the excitation itself. In particular, the field shifts and their uncertainties can be radically suppressed (by two to four orders of magnitude) in comparison with the usual Ramsey method (using two equal pulses) as well as with single-pulse Rabi spectroscopy. Atom interferometers and optical clocks based on two-photon transitions, heavily forbidden transitions, or magnetically induced spectroscopy could significantly benefit from this method. In the latter case, these frequency shifts can be suppressed considerably below a fractional levelmore » of 10{sup -17}. Moreover, our approach opens the door for high-precision optical clocks based on direct frequency comb spectroscopy.« less
NASA Astrophysics Data System (ADS)
Poulain, Pierre-Marie; Luther, Douglas S.; Patzert, William C.
1992-11-01
Two techniques have been developed for estimating statistics of inertial oscillations from satellite-tracked drifters. These techniques overcome the difficulties inherent in estimating such statistics from data dependent upon space coordinates that are a function of time. Application of these techniques to tropical surface drifter data collected during the NORPAX, EPOCS, and TOGA programs reveals a latitude-dependent, statistically significant "blue shift" of inertial wave frequency. The latitudinal dependence of the blue shift is similar to predictions based on "global" internal wave spectral models, with a superposition of frequency shifting due to modification of the effective local inertial frequency by the presence of strongly sheared zonal mean currents within 12° of the equator.
Direct measurement for organic solvents diffusion using ultra-sensitive optical resonator
NASA Astrophysics Data System (ADS)
Ali, Amir R.; Elias, Catherine M.
2017-06-01
In this paper, novel techniques using ultra-sensitive chemical optical sensor based on whispering gallery modes (WGM) are proposed through two different configurations. The first one will use a composite micro-sphere, when the solvent interacts with the polymeric optical sensors through diffusion the sphere start to swallow that solvent. In turn, that leads to change the morphology and mechanical properties of the polymeric spheres. Also, these changes could be measured by tracking the WGM shifts. Several experiments were carried out to study the solvent induced WGM shift using microsphere immersed in a solvent atmosphere. It can be potentially used for sensing the trace organic solvents like ethanol and methanol. The second configuration will use a composite beam nitrocellulose composite (NC) structure that acts as a sensing element. In this configuration, a beam is anchored to a substrate in one end, and the other end is compressing the polymeric sphere causing a shift in its WGM. When a chemical molecule is attached to the beam, the resonant frequency of the cantilever will be changed for a certain amount. By sensing this certain resonant frequency change, the existence of a single chemical molecule can be detected. A preliminary experimental model is developed to describe the vibration of the beam structure. The resonant frequency change of the cantilever due to attached mass is examined imperially using acetone as an example. Breath diagnosis can use this configuration in diabetic's diagnosis. Since, solvent like acetone concentration in human breath leads to a quick, convenient, accurate and painless breath diagnosis of diabetics. These micro-optical sensors have been examined using preliminary experiments to fully investigate its response. The proposed chemical sensor can achieve extremely high sensitivity in molecular level.
Ishigaki, Mika; Meksiarun, Phiranuphon; Kitahama, Yasutaka; Zhang, Leilei; Hashimoto, Hideki; Genkawa, Takuma; Ozaki, Yukihiro
2017-08-31
The present study investigates the structure of lycopene aggregates both in vitro and in vivo using ultraviolet-visible (UV-vis) and Raman spectroscopies. The electronic absorption bands of the J- and H-aggregates in vitro shift to lower and higher energies, respectively, compared to that of the lycopene monomer. Along with these results, the frequencies of the ν 1 Raman bands were shifted to lower and higher frequencies, respectively. By plotting the frequencies of the ν 1 Raman band against the S 0 → S 2 transition energy, a linear relationship between the data set with different aggregation conformations can be obtained. Therefore, the band positions depending on the different conformations can be explained based on the idea that the effective conjugated C═C chain lengths within lycopene molecules are different due to the environmental effect (site-shift effect) caused by the aggregation conformation. Applying this knowledge to the in vivo measurement of a tomato fruit sample, the relationship between the aggregation conformation of lycopene and the spectral patterns observed in the UV-vis as well as Raman spectra in different parts of tomato fruits was discussed in detail. The results showed that the concentration of lycopene (particularly that of the J-aggregate) specifically increased, whereas that of chlorophyll decreased, with ripening. Furthermore, Raman imaging indicated that lycopene with different aggregate conformations was distributed inhomogeneously, even within one sample. The layer formation in tomato tissues with high concentrations of J- and H-aggregates was successfully visualized. In this manner, the presence of lycopene distributions with different aggregate conformations was unveiled in vivo.
Presynaptic pH and vesicle fusion in Drosophila larvae neurones.
Caldwell, Lesley; Harries, Peter; Sydlik, Sebastian; Schwiening, Christof J
2013-11-01
Both intracellular pH (pHi) and synaptic cleft pH change during neuronal activity yet little is known about how these pH shifts might affect synaptic transmission by influencing vesicle fusion. To address this we imaged pH- and Ca(2+) -sensitive fluorescent indicators (HPTS, Oregon green) in boutons at neuromuscular junctions. Electrical stimulation of motor nerves evoked presynaptic Ca(2+) i rises and pHi falls (∼0.1 pH units) followed by recovery of both Ca(2+) i and pHi. The plasma-membrane calcium ATPase (PMCA) inhibitor, 5(6)-carboxyeosin diacetate, slowed both the calcium recovery and the acidification. To investigate a possible calcium-independent role for the pHi shifts in modulating vesicle fusion we recorded post-synaptic miniature end-plate potential (mEPP) and current (mEPC) frequency in Ca(2+) -free solution. Acidification by propionate superfusion, NH(4)(+) withdrawal, or the inhibition of acid extrusion on the Na(+)/H(+) exchanger (NHE) induced a rise in miniature frequency. Furthermore, the inhibition of acid extrusion enhanced the rise induced by propionate addition and NH(4)(+) removal. In the presence of NH(4)(+), 10 out of 23 cells showed, after a delay, one or more rises in miniature frequency. These findings suggest that Ca(2+) -dependent pHi shifts, caused by the PMCA and regulated by NHE, may stimulate vesicle release. Furthermore, in the presence of membrane permeant buffers, exocytosed acid or its equivalents may enhance release through positive feedback. This hitherto neglected pH signalling, and the potential feedback role of vesicular acid, could explain some important neuronal excitability changes associated with altered pH and its buffering. Copyright © 2013 Wiley Periodicals, Inc.
Analysis of frequency shifting in seismic signals using Gabor-Wigner transform
NASA Astrophysics Data System (ADS)
Kumar, Roshan; Sumathi, P.; Kumar, Ashok
2015-12-01
A hybrid time-frequency method known as Gabor-Wigner transform (GWT) is introduced in this paper for examining the time-frequency patterns of earthquake damaged buildings. GWT is developed by combining the Gabor transform (GT) and Wigner-Ville distribution (WVD). GT and WVD have been used separately on synthetic and recorded earthquake data to identify frequency shifting due to earthquake damages, but GT is prone to windowing effect and WVD involves ambiguity function. Hence to obtain better clarity and to remove the cross terms (frequency interference), GT and WVD are judiciously combined and the resultant GWT used to identify frequency shifting. Synthetic seismic response of an instrumented building and real-time earthquake data recorded on the building were investigated using GWT. It is found that GWT offers good accuracy for even slow variations in frequency, good time-frequency resolution, and localized response. Presented results confirm the efficacy of GWT when compared with GT and WVD used separately. Simulation results were quantified by the Renyi entropy measures and GWT shown to be an adequate technique in identifying localized response for structural damage detection.
Friedman, Y; Yudkin, E; Nowik, I; Felner, I; Wille, H-C; Röhlsberger, R; Haber, J; Wortmann, G; Arogeti, S; Friedman, M; Brand, Z; Levi, N; Shafir, I; Efrati, O; Frumson, T; Finkelstein, A; Chumakov, A I; Kantor, I; Rüffer, R
2015-05-01
Many Mössbauer spectroscopy (MS) experiments have used a rotating absorber in order to measure the second-order transverse Doppler (TD) shift, and to test the validity of the Einstein time dilation theory. From these experiments, one may also test the clock hypothesis (CH) and the time dilation caused by acceleration. In such experiments the absorption curves must be obtained, since it cannot be assumed that there is no broadening of the curve during the rotation. For technical reasons, it is very complicated to keep the balance of a fast rotating disk if there are moving parts on it. Thus, the Mössbauer source on a transducer should be outside the disk. Friedman and Nowik have already predicted that the X-ray beam finite size dramatically affects the MS absorption line and causes its broadening. We provide here explicit formulas to evaluate this broadening for a synchrotron Mössbauer source (SMS) beam. The broadening is linearly proportional to the rotation frequency and to the SMS beam width at the rotation axis. In addition, it is shown that the TD shift and the MS line broadening are affected by an additional factor assigned as the alignment shift which is proportional to the frequency of rotation and to the distance between the X-ray beam center and the rotation axis. This new shift helps to align the disk's axis of rotation to the X-ray beam's center. To minimize the broadening, one must focus the X-ray on the axis of the rotating disk and/or to add a slit positioned at the center, to block the rays distant from the rotation axis of the disk. Our experiment, using the (57)Fe SMS, currently available at the Nuclear Resonance beamline (ID18) at the ESRF, with a rotating stainless steel foil, confirmed our predictions. With a slit installed at the rotation axis (reducing the effective beam width from 15.6 µm to 5.4 µm), one can measure a statistically meaningful absorption spectrum up to 300 Hz, while, without a slit, such spectra could be obtained up to 100 Hz only. Thus, both the broadening and the alignment shift are very significant and must be taken into consideration in any rotating absorber experiment. Here a method is offered to measure accurately the TD shift and to test the CH.
NASA Astrophysics Data System (ADS)
Temuriantz, N. A.; Martinyuk, V. S.; Ptitsyna, N. G.; Villoresi, G.; Iucci, N.; Tyasto, M. I.; Dorman, L. I.
During last decades it was shown by many authors that ultra-low and extremely low frequency electric and magnetic fields ULF 0-10 Hz ELF 10-1000 Hz may produce biological effects and consequently may be a possible source for health problems Spaceflight electric and magnetic environments are characterized by complex combination of static and time-varying components in ULF-ELF range and by high variability The objective of this study was to investigate the possible influence of such magnetic fields on rats to understand the pathway regarding functional state of cardiovascular system Magnetic field MF pattern with variable complex spectra in 0-150 Hz frequency range was simulated using 3-axial Helmholtz coils and special computer-based equipment The effect of the real world MF exposure on rats was also tested in combination with hypokinetic stress condition which is typical for spaceflights It was revealed that variable complex-spectrum MF acts as a weak or moderate stress-like factor which amplifies and or modifies the functional shifts caused by other stress-factors The value and direction of the functional shifts caused by MF exposure significantly depend on gender individual-typological constitutional features and also on the physiological state norm stress of organism Our results support the idea that variable complex-spectrum MF action involves sympathetic activation overload in cholesterol transport in blood and also secretor activation of tissue basophyls mast cells that can influence the regional haemodynamics These
Pitch glide effect induced by a nonlinear string-barrier interaction
NASA Astrophysics Data System (ADS)
Kartofelev, Dmitri; Stulov, Anatoli; Välimäki, Vesa
2015-10-01
Interactions of a vibrating string with its supports and other spatially distributed barriers play a significant role in the physics of many stringed musical instruments. It is well known that the tone of the string vibrations is determined by the string supports, and that the boundary conditions of the string termination may cause a short-lasting initial fundamental frequency shifting. Generally, this phenomenon is associated with the nonlinear modulation of the stiff string tension. The aim of this paper is to study the initial frequency glide phenomenon that is induced only by the string-barrier interaction, apart from other possible physical causes, and without the interfering effects of dissipation and dispersion. From a numerical simulation perspective, this highly nonlinear problem may present various difficulties, not the least of which is the risk of numerical instability. We propose a numerically stable and a purely kinematic model of the string-barrier interaction, which is based on the travelling wave solution of the ideal string vibration. The model is capable of reproducing the motion of the vibrating string exhibiting the initial fundamental frequency glide, which is caused solely by the complex nonlinear interaction of the string with its termination. The results presented in this paper can expand our knowledge and understanding of the timbre evolution and the physical principles of sound generation of numerous stringed instruments, such as lutes called the tambura, sitar and biwa.
Frank, T
2001-04-01
The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using Sennheiser HDA 200 earphones should equal the 1998 interim ISO RETSPLs from 8 to 16 kHz. Further, because the differences between repeated thresholds were well within +/-10 dB and had an extremely low false-positive rate in reference to the ASHA 1994 criteria for a significant threshold shift due to ototoxicity, a Sennheiser HDA 200 earphone can be used for serial monitoring to determine whether significant high-frequency threshold shifts have occurred for patients receiving potentially ototoxic drug therapy.
Hoehmann, D; Müller, S; Dornhoffer, J L
1995-01-01
Low-frequency acoustic biasing using an intensive phase-shifted, low-frequency masker was studied according to its ability to determine disorders of cochlear micromechanics following noise trauma in the guinea pig as animal model. Statistical analyses proved that this technique allowed electrophysiological differentiation of controls versus groups with different degrees of experimentally induced threshold shifts. To substantiate group differences an intensity of at least 70 dB SPL was required for the 52 Hz masker and the difference in relation to the test-tone intensity had to be +/- 10 or +/- 20 dB SPL. The noise-traumatized cochlea could be identified by means of a threshold shift for the 5 microV pseudothreshold, a low modulation span of the compound action potential amplitude (< 25-50 microV frequency dependent), and reduced positive summating potential amplitude with negative non-modulating values within the different measurement phases for 1 and 2 kHz stimulation.
Turgut, Altan; Orr, Marshall; Pasewark, Bruce
2007-05-01
Waveguide invariant theory is used to describe the frequency shifts of constant acoustic intensity level curves in broadband signal spectrograms measured at the New Jersey Shelf during the winter of 2003. The broadband signals (270-330 Hz) were transmitted from a fixed source and received at three fixed receivers, located at 10, 20, and 30 km range along a cross-shelf propagation track. The constant acoustic intensity level curves of the received signals indicate regular frequency shifts that can be well predicted by the change in water depth observed through tens of tidal cycles. A second pattern of frequency shifts is observed at only 30 km range where significant variability of slope-water intrusion was measured. An excellent agreement between observed frequency shifts of the constant acoustic intensity levels and those predicted by the change in tide height and slope water elevations suggests the capability of long-term acoustic monitoring of tide and slope water intrusions in winter conditions.
The Effect of Shift Work on Urogenital Disease: a Systematic Review.
Deng, Nanfu; Haney, Nora M; Kohn, Taylor P; Pastuszak, Alexander W; Lipshultz, Larry I
2018-05-28
Non-standard shift work schedules negatively impact the overall health of shift workers, and several studies have shown that shift work, specifically, is detrimental to urogenital health. The aims of this study are to systematically review the literature and determine the effect of shift work on the outcomes of hypogonadism, male infertility, lower urinary tract symptoms, and urogenital cancers. Recent evidence supports associations between non-standard shift work and an increase in the frequency of prostate cancer and the severity of erectile dysfunction, lower urinary tract symptoms, and hypogonadal symptoms, as well as worsening of semen parameters and fertility. These associations are strengthened by the presence of shift work sleep disorder (SWSD) which affects up to 20% of shift workers. No studies have assessed the impact of shift work on the frequency or severity of nephrolithiasis, interstitial cystitis, pelvic pain, prostatitis, or urinary tract infections. Non-standard shift work has been associated with a variety of negative health outcomes and urologic complications, especially with concurrent shift work sleep disorder. Recognition of these elevated risks among shift workers can aid in more effective screening for urologic conditions.
Yang, R G; Zhang, J; Zhai, Z H; Zhai, S Q; Liu, K; Gao, J R
2015-08-10
Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.
Seismic sensitivity to sub-surface solar activity from 18 yr of GOLF/SoHO observations
NASA Astrophysics Data System (ADS)
Salabert, D.; García, R. A.; Turck-Chièze, S.
2015-06-01
Solar activity has significantly changed over the last two Schwabe cycles. After a long and deep minimum at the end of Cycle 23, the weaker activity of Cycle 24 contrasts with the previous cycles. In this work, the response of the solar acoustic oscillations to solar activity is used in order to provide insights into the structural and magnetic changes in the sub-surface layers of the Sun during this on-going unusual period of low activity. We analyze 18 yr of continuous observations of the solar acoustic oscillations collected by the Sun-as-a-star GOLF instrument on board the SoHO spacecraft. From the fitted mode frequencies, the temporal variability of the frequency shifts of the radial, dipolar, and quadrupolar modes are studied for different frequency ranges that are sensitive to different layers in the solar sub-surface interior. The low-frequency modes show nearly unchanged frequency shifts between Cycles 23 and 24, with a time evolving signature of the quasi-biennial oscillation, which is particularly visible for the quadrupole component revealing the presence of a complex magnetic structure. The modes at higher frequencies show frequency shifts that are 30% smaller during Cycle 24, which is in agreement with the decrease observed in the surface activity between Cycles 23 and 24. The analysis of 18 yr of GOLF oscillations indicates that the structural and magnetic changes responsible for the frequency shifts remained comparable between Cycle 23 and Cycle 24 in the deeper sub-surface layers below 1400 km as revealed by the low-frequency modes. The frequency shifts of the higher-frequency modes, sensitive to shallower regions, show that Cycle 24 is magnetically weaker in the upper layers of Sun. Appendices are available in electronic form at http://www.aanda.orgThe following 68 GOLF frequency tables are available and Table A.1 is also available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/578/A137
Shift work and overall and cause-specific mortality in the Danish nurse cohort.
Jørgensen, Jeanette Therming; Karlsen, Sashia; Stayner, Leslie; Andersen, Johnni; Andersen, Zorana Jovanovic
2017-03-01
Objectives Evidence of an effect of shift work on all-cause and cause-specific mortality is inconsistent. This study aims to examine whether shift work is associated with increased all-cause and cause-specific mortality. Methods We linked 28 731 female nurses (age ≥44 years), recruited in 1993 or 1999 from the Danish nurse cohort where they reported information on shift work (night, evening, rotating, or day), to the Danish Register of Causes of Death to identify deaths up to 2013. We used Cox regression models with age as the underlying scale to examine the associations between night, evening, and rotating shift work (compared to day shift work) and all-cause and cause-specific mortality in models adjusted for potentially confounding variables. Results Of 18 015 nurses included in this study, 1616 died during the study time period from the following causes: cardiovascular disease (N=217), cancer (N= 945), diabetes (N=20), Alzheimer's disease or dementia (N=33), and psychiatric diseases (N=67). We found that working night [hazard ratio (HR) 1.26, 95% confidence interval 95% CI) 1.05-1.51] or evening (HR 1.29, 95% CI 1.11-1.49) shifts was associated with a significant increase in all-cause mortality when compared to working day shift. We found a significant association of night shift work with cardiovascular disease (HR 1.71, 95% CI 1.09-2.69) and diabetes (HR 12.0, 95% CI 3.17-45.2, based on 8 cases) and none with overall cancer mortality (HR 1.05, 95% CI 0.81-1.35) or mortality from psychiatric diseases (HR 1.17, 95% CI 0.47-2.92). Finally, we found strong association between evening (HR 4.28, 95% CI 1.62-11.3) and rotating (HR 5.39, 95% CI 2.35-12.3) shift work and mortality from Alzheimer's disease and dementia (based on 8 and 14 deaths among evening and rotating shift workers, respectively). Conclusions Women working night and evening shifts have increased all-cause, cardiovascular, diabetes, and Alzheimer's and dementia mortality.
Influence of the ac-Stark shift on GPS atomic clock timekeeping
NASA Astrophysics Data System (ADS)
Formichella, V.; Camparo, J.; Tavella, P.
2017-01-01
The ac-Stark shift (or light shift) is a fundamental aspect of the field/atom interaction arising from virtual transitions between atomic states, and as Alfred Kastler noted, it is the real-photon counterpart of the Lamb shift. In the rubidium atomic frequency standards (RAFS) flying on Global Positioning System (GPS) satellites, it plays an important role as one of the major perturbations defining the RAFS' frequency: the rf-discharge lamp in the RAFS creates an atomic signal via optical pumping and simultaneously perturbs the atoms' ground-state hyperfine splitting via the light shift. Though the significance of the light shift has been known for decades, to date there has been no concrete evidence that it limits the performance of the high-quality RAFS flying on GPS satellites. Here, we show that the long-term frequency stability of GPS RAFS is primarily determined by the light shift as a consequence of stochastic jumps in lamplight intensity. Our results suggest three paths forward for improved GPS system timekeeping: (1) reduce the light-shift coefficient of the RAFS by careful control of the lamp's spectrum; (2) operate the lamp under conditions where lamplight jumps are not so pronounced; and (3) employ a light source for optical pumping that does not suffer pronounced light jumps (e.g., a diode laser).
Improved Intrapulse Raman Scattering Control via Asymmetric Airy Pulses
NASA Astrophysics Data System (ADS)
Hu, Yi; Tehranchi, Amirhossein; Wabnitz, Stefan; Kashyap, Raman; Chen, Zhigang; Morandotti, Roberto
2015-02-01
We experimentally demonstrate the possibility of tuning the frequency of a laser pulse via the use of an Airy pulse-seeded soliton self-frequency shift. The intrinsically asymmetric nature of Airy pulses, typically featured by either leading or trailing oscillatory tails (relatively to the main lobe), is revealed through the nonlinear generation of both a primary and a secondary Raman soliton self-frequency shift, a phenomenon which is driven by the soliton fission processes. The resulting frequency shift can be carefully controlled by using time-reversed Airy pulses or, alternatively, by applying an offset to the cubic phase modulation used to generate the pulses. When compared with the use of conventional chirped Gaussian pulses, our technique brings about unique advantages in terms of both efficient frequency tuning and feasibility, along with the generation and control of multicolor Raman solitons with enhanced tunability. Our theoretical analysis agrees well with our experimental observations.
NASA Astrophysics Data System (ADS)
Zhu, Zihang; Zhao, Shanghong; Li, Xuan; Lin, Tao; Hu, Dapeng
2018-03-01
Photonic microwave frequency down-conversion with independent multichannel phase shifting and zero-intermediate frequency (IF) receiving is proposed and demonstrated by simulation. By combined use of a phase modulator (PM) in a sagnac loop and an optical bandpass filter (OBPF), orthogonal polarized carrier suppression single sideband (CS-SSB) signals are obtained. By adjusting the polarization controllers (PCs) to introduce the phase difference in the optical domain and using balanced detection to eliminate the direct current components, the phase of the generated IF signal can be arbitrarily tuned. Besides, the radio frequency (RF) vector signal can be also frequency down-converted to baseband directly by choosing two quadrature channels. In the simulation, high gain and continuously tunable phase shifts over the 360 degree range are verified. Furthermore, 2.5 Gbit/s RF vector signals centered at 10 GHz with different modulation formats are successfully demodulated.
Wearable Contactless Respiration Sensor Based on Multi-Material Fibers Integrated into Textile
Guay, Philippe; Gorgutsa, Stepan; LaRochelle, Sophie; Messaddeq, Younes
2017-01-01
In this paper, we report on a novel sensor for the contactless monitoring of the respiration rate, made from multi-material fibers arranged in the form of spiral antenna (2.45 GHz central frequency). High flexibility of the used composite metal-glass-polymer fibers permits their integration into a cotton t-shirt without compromising comfort or restricting movement of the user. At the same time, change of the antenna geometry, due to the chest expansion and the displacement of the air volume in the lungs, is found to cause a significant shift of the antenna operational frequency, thus allowing respiration detection. In contrast with many current solutions, respiration is detected without attachment of the electrodes of any kind to the user’s body, neither direct contact of the fiber with the skin is required. Respiration patterns for two male volunteers were recorded with the help of a sensor prototype integrated into standard cotton t-shirt in sitting, standing, and lying scenarios. The typical measured frequency shift for the deep and shallow breathing was found to be in the range 120–200 MHz and 10–15 MHz, respectively. The same spiral fiber antenna is also shown to be suitable for short-range wireless communication, thus allowing respiration data transmission, for example, via the Bluetooth protocol, to mobile handheld devices. PMID:28481252
Design and Processing of a Novel Chaos-Based Stepped Frequency Synthesized Wideband Radar Signal.
Zeng, Tao; Chang, Shaoqiang; Fan, Huayu; Liu, Quanhua
2018-03-26
The linear stepped frequency and linear frequency shift keying (FSK) signal has been widely used in radar systems. However, such linear modulation signals suffer from the range-Doppler coupling that degrades radar multi-target resolution. Moreover, the fixed frequency-hopping or frequency-coded sequence can be easily predicted by the interception receiver in the electronic countermeasures (ECM) environments, which limits radar anti-jamming performance. In addition, the single FSK modulation reduces the radar low probability of intercept (LPI) performance, for it cannot achieve a large time-bandwidth product. To solve such problems, we propose a novel chaos-based stepped frequency (CSF) synthesized wideband signal in this paper. The signal introduces chaotic frequency hopping between the coherent stepped frequency pulses, and adopts a chaotic frequency shift keying (CFSK) and phase shift keying (PSK) composited coded modulation in a subpulse, called CSF-CFSK/PSK. Correspondingly, the processing method for the signal has been proposed. According to our theoretical analyses and the simulations, the proposed signal and processing method achieve better multi-target resolution and LPI performance. Furthermore, flexible modulation is able to increase the robustness against identification of the interception receiver and improve the anti-jamming performance of the radar.
NASA Technical Reports Server (NTRS)
Sanders, Steven (Inventor); Waarts, Robert G. (Inventor)
2001-01-01
A frequency conversion system comprises first and second gain sources providing first and second frequency radiation outputs where the second gain source receives as input the output of the first gain source and, further, the second gain source comprises a Raman or Brillouin gain fiber for wave shifting a portion of the radiation of the first frequency output into second frequency radiation output to provided a combined output of first and second frequencies. Powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.
NASA Astrophysics Data System (ADS)
Li, Jingnan; Wang, Shangxu; Yang, Dengfeng; Tang, Genyang; Chen, Yangkang
2018-02-01
Seismic waves propagating in the subsurface suffer from attenuation, which can be represented by the quality factor Q. Knowledge of Q plays a vital role in hydrocarbon exploration. Many methods to measure Q have been proposed, among which the central frequency shift (CFS) and the peak frequency shift (PFS) are commonly used. However, both methods are under the assumption of a particular shape for amplitude spectra, which will cause systematic error in Q estimation. Recently a new method to estimate Q has been proposed to overcome this disadvantage by using frequency weighted exponential (FWE) function to fit amplitude spectra of different shapes. In the FWE method, a key procedure is to calculate the central frequency and variance of the amplitude spectrum. However, the amplitude spectrum is susceptible to noise, whereas the power spectrum is less sensitive to random noise and has better anti-noise performance. To enhance the robustness of the FWE method, we propose a novel hybrid method by combining the advantage of the FWE method and the power spectrum, which is called the improved FWE method (IFWE). The basic idea is to consider the attenuation of the power spectrum instead of the amplitude spectrum and to use a modified FWE function to fit power spectra, according to which we derive a new Q estimation formula. Tests of noisy synthetic data show that the IFWE are more robust than the FWE. Moreover, the frequency bandwidth selection in the IFWE can be more flexible than that in the FWE. The application to field vertical seismic profile data and surface seismic data further demonstrates its validity.
Generalized Autobalanced Ramsey Spectroscopy of Clock Transitions
NASA Astrophysics Data System (ADS)
Yudin, V. I.; Taichenachev, A. V.; Basalaev, M. Yu.; Zanon-Willette, T.; Pollock, J. W.; Shuker, M.; Donley, E. A.; Kitching, J.
2018-05-01
When performing precision measurements, the quantity being measured is often perturbed by the measurement process itself. Such measurements include precision frequency measurements for atomic clock applications carried out with Ramsey spectroscopy. With the aim of eliminating probe-induced perturbations, a method of generalized autobalanced Ramsey spectroscopy (GABRS) is presented and rigorously substantiated. The usual local-oscillator frequency control loop is augmented with a second control loop derived from secondary Ramsey sequences interspersed with the primary sequences and with a different Ramsey period. This second loop feeds back to a secondary clock variable and ultimately compensates for the perturbation of the clock frequency caused by the measurements in the first loop. We show that such a two-loop scheme can lead to perfect compensation for measurement-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors that are typical of other hyper-Ramsey schemes. Several variants of GABRS are explored based on different secondary variables including added relative phase shifts between Ramsey pulses, external frequency-step compensation, and variable second-pulse duration. We demonstrate that a universal antisymmetric error signal, and hence perfect compensation at a finite modulation amplitude, is generated only if an additional frequency step applied during both Ramsey pulses is used as the concomitant variable parameter. This universal technique can be applied to the fields of atomic clocks, high-resolution molecular spectroscopy, magnetically induced and two-photon probing schemes, Ramsey-type mass spectrometry, and the field of precision measurements. Some variants of GABRS can also be applied for rf atomic clocks using coherent-population-trapping-based Ramsey spectroscopy of the two-photon dark resonance.
Staveski, Sandra L; Tesoro, Tiffany M; Cisco, Michael J; Roth, Stephen J; Shin, Andrew Y
2014-01-01
The use of sedative and analgesic medications is directly linked to patient outcomes. The practice of administering as-needed sedative or analgesic medications deserves further exploration. We hypothesized that important variations exist in the practice of administering as-needed medications in the intensive care unit (ICU). We aimed to determine the influence of time of day on the practice of administering as-needed sedative or analgesic medications to children in the ICU. Medication administration records of patients admitted to our pediatric cardiovascular ICU during a 4-month period were reviewed to determine the frequency and timing of as-needed medication usage by shift. A total of 152 ICU admissions (1854 patient days) were reviewed. A significantly greater number of as-needed doses were administered during the night shift (fentanyl, P = .005; lorazepam, P = .03; midazolam, P = .0003; diphenhydramine, P = .0003; and chloral hydrate, P = .0006). These differences remained statistically significant after excluding doses given during the first 6 hours after cardiovascular surgery. Morphine administration was similar between shifts (P = .08). We identified a pattern of increased administration of as-needed sedative or analgesic medications during nights. Further research is needed to identify the underlying causes of this practice variation.
Fuglevand, A J; Macefield, V G; Bigland-Ritchie, B
1999-04-01
Modulation of motor unit activation rate is a fundamental process by which the mammalian nervous system encodes muscle force. To identify how rate coding of force may change as a consequence of fatigue, intraneural microstimulation of motor axons was used to elicit twitch and force-frequency responses before and after 2 min of intermittent stimulation (40-Hz train for 330 ms, 1 train/s) in single motor units of human long finger flexor muscles and intrinsic hand muscles. Before fatigue, two groups of units could be distinguished based on the stimulus frequency needed to elicit half-maximal force; group 1 (n = 8) required 9.1 +/- 0.5 Hz (means +/- SD), and group 2 (n = 5) required 15.5 +/- 1.1 Hz. Twitch contraction times were significantly different between these two groups (group 1 = 66. 5 ms; group 2 = 45.9 ms). Overall 18% of the units were fatigue resistant [fatigue index (FI) > 0.75], 64% had intermediate fatigue sensitivity (0.25 = FI = 0.75), and 18% were fatigable (FI < 0. 25). However, fatigability and tetanic force were not significantly different among groups. Therefore unlike findings in some other mammals, fast-contracting motor units were neither stronger nor more susceptible to fatigue than slowly contracting units. Fatigue, however, was found to be greatest in those units that initially exerted the largest forces. Despite significant slowing of contractile responses, fatigue caused the force-frequency relation to become displaced toward higher frequencies (44 +/- 41% increase in frequency for half-maximal force). Moreover, the greatest shift in the force-frequency relation occurred among those units exhibiting the largest force loss. A selective deficit in force at low frequencies of stimulation persisted for several minutes after the fatigue task. Overall, these findings suggest that with fatigue higher activation rates must be delivered to motor units to maintain the same relative level of force. Questions regarding classification of motor units and possible mechanisms by which fatigue-related slowing might coexist with a shift in the force-frequency curve toward higher frequencies are discussed.
Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS
NASA Astrophysics Data System (ADS)
Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru
2016-04-01
The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2-8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied.
Frequency stabilization in nonlinear MEMS and NEMS oscillators
Lopez, Omar Daniel; Antonio, Dario
2014-09-16
An illustrative system includes an amplifier operably connected to a phase shifter. The amplifier is configured to amplify a voltage from an oscillator. The phase shifter is operably connected to a driving amplitude control, wherein the phase shifter is configured to phase shift the amplified voltage and is configured to set an amplitude of the phase shifted voltage. The oscillator is operably connected to the driving amplitude control. The phase shifted voltage drives the oscillator. The oscillator is at an internal resonance condition, based at least on the amplitude of the phase shifted voltage, that stabilizes frequency oscillations in the oscillator.
NASA Technical Reports Server (NTRS)
Hurd, William J.; Estabrook, Polly; Racho, Caroline S.; Satorius, Edgar H.
2002-01-01
For planetary lander missions, the most challenging phase of the spacecraft to ground communications is during the entry, descent, and landing (EDL). As each 2003 Mars Exploration Rover (MER) enters the Martian atmosphere, it slows dramatically. The extreme acceleration and jerk cause extreme Doppler dynamics on the X-band signal received on Earth. When the vehicle slows sufficiently, the parachute is deployed, causing almost a step in deceleration. After parachute deployment, the lander is lowered beneath the parachute on a bridle. The swinging motion of the lander imparts high Doppler dynamics on the signal and causes the received signal strength to vary widely, due to changing antenna pointing angles. All this time, the vehicle transmits important health and status information that is especially critical if the landing is not successful. Even using the largest Deep Space Network antennas, the weak signal and high dynamics render it impossible to conduct reliable phase coherent communications. Therefore, a specialized form of frequency-shift-keying will be used. This paper describes the EDL scenario, the signal conditions, the methods used to detect and frequency-track the carrier and to detect the data modulation, and the resulting performance estimates.
NASA Astrophysics Data System (ADS)
Baranov, A. A.; Ermak, S. V.; Kulachenkov, N. K.; Petrenko, M. V.; Sagitov, E. A.; Semenov, V. V.
2017-11-01
This paper presents the results of investigation Stark shift effect influence on the long-term stability of a dual scheme of quantum magnetometers. Such scheme allows suppressing Stark shift components when a certain pumping light polarization is applied. As a result, long-term stability of a quantum sensor increases. However, when low-frequency (LF) and microwave fields are attached to a single vapor cell a coherence circulation in hyperfine structure of alkali atoms takes place. Physical origin of this effect is associated with the so called “dressed” atom theory, when atom is “dressed” by LF field. It yields in multiphoton absorption and resonance frequency shift. First estimates for this shift based on density matrix evolution formalism are provided in the paper.
Comprehensive time average digital holographic vibrometry
NASA Astrophysics Data System (ADS)
Psota, Pavel; Lédl, Vít; Doleček, Roman; Mokrý, Pavel; Vojtíšek, Petr; Václavík, Jan
2016-12-01
This paper presents a method that simultaneously deals with drawbacks of time-average digital holography: limited measurement range, limited spatial resolution, and quantitative analysis of the measured Bessel fringe patterns. When the frequency of the reference wave is shifted by an integer multiple of frequency at which the object oscillates, the measurement range of the method can be shifted either to smaller or to larger vibration amplitudes. In addition, phase modulation of the reference wave is used to obtain a sequence of phase-modulated fringe patterns. Such fringe patterns can be combined by means of phase-shifting algorithms, and amplitudes of vibrations can be straightforwardly computed. This approach independently calculates the amplitude values in every single pixel. The frequency shift and phase modulation are realized by proper control of Bragg cells and therefore no additional hardware is required.
NASA Astrophysics Data System (ADS)
Zhang, Yan; Fu, Li-Yun; Ma, Yuchuan; Hu, Junhua
2016-11-01
Zuojiazhuang and Baodi are two adjacent wells ( 50 km apart) in northern China. The large 2008 M w 7.9 Wenchuan and 2011 M w 9.1 Tohoku earthquakes induced different co-seismic water-level responses in these far-field (>1000 km) wells. The co-seismic water-level changes in the Zuojiazhuang well exhibited large amplitudes ( 2 m), whereas those in the Baodi well were small and unclear ( 0.05 m). The mechanism of the different co-seismic hydraulic responses in the two wells needs to be revealed. In this study, we used the barometric responses in different frequency domains and the phase shifts and amplitude ratios of the tidal responses (M2 wave), together with the well logs, to explain this inconformity. Our calculations show that the co-seismic phase shifts of the M2 wave decreased or remained unchanged in the Baodi well, which was quite different from the Zuojiazhuang well and from the commonly accepted phenomena. According to the well logs, the lithology of the Baodi well is characterized by the presence of a significant amount of shale. The low porosity/permeability of shale in the Baodi well could be the cause for the unchanged and decreased phase shifts and tiny co-seismic water-level responses. In addition, shale is one of the causes of positive phase shifts and indicates a vertical water-level flow, which may be due to a semi-confined aquifer or the complex and anisotropic fracturing of shale.
Shifts in fisheries management: adapting to regime shifts
King, Jacquelynne R.; McFarlane, Gordon A.; Punt, André E.
2015-01-01
For many years, fisheries management was based on optimizing yield and maintaining a target biomass, with little regard given to low-frequency environmental forcing. However, this policy was often unsuccessful. In the last two to three decades, fisheries science and management have undergone a shift towards balancing sustainable yield with conservation, with the goal of including ecosystem considerations in decision-making frameworks. Scientific understanding of low-frequency climate–ocean variability, which is manifested as ecosystem regime shifts and states, has led to attempts to incorporate these shifts and states into fisheries assessment and management. To date, operationalizing these attempts to provide tactical advice has met with limited success. We review efforts to incorporate regime shifts and states into the assessment and management of fisheries resources, propose directions for future investigation and outline a potential framework to include regime shifts and changes in ecosystem states into fisheries management.
Generation of waves in the Venus mantle by the ion acoustic beam instability
NASA Technical Reports Server (NTRS)
Huba, J. D.
1993-01-01
The ion acoustic beam instability is suggested as a mechanism to produce wave turbulence observed in the Venus mantle at frequencies 100 Hz and 730 Hz. The plasma is assumed to consist of a stationary cold O(+) ion plasma and a flowing, shocked solar wind plasma. The O(+) ions appear as a beam relative to the flowing ionosheath plasma which provides the free energy to drive the instability. The plasma is driven unstable by inverse electron Landau damping of an ion acoustic wave associated with the cold ionospheric O(+) ions. The instability can directly generate the observed 100 Hz waves in the Venus mantle as well as the observed 730 Hz waves through the Doppler shift of the frequency caused by the satellite motion.
Tangential velocity measurement using interferometric MTI radar
Doerry, Armin W.; Mileshosky, Brian P.; Bickel, Douglas L.
2006-01-03
Radar systems use time delay measurements between a transmitted signal and its echo to calculate range to a target. Ranges that change with time cause a Doppler offset in phase and frequency of the echo. Consequently, the closing velocity between target and radar can be measured by measuring the Doppler offset of the echo. The closing velocity is also known as radial velocity, or line-of-sight velocity. Doppler frequency is measured in a pulse-Doppler radar as a linear phase shift over a set of radar pulses during some Coherent Processing Interval (CPI). An Interferometric Moving Target Indicator (MTI) radar can be used to measure the tangential velocity component of a moving target. Multiple baselines, along with the conventional radial velocity measurement, allow estimating the true 3-D velocity of a target.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.
Weavers, Paul T; Tao, Shengzhen; Trzasko, Joshua D; Frigo, Louis M; Shu, Yunhong; Frick, Matthew A; Lee, Seung-Kyun; Foo, Thomas K-F; Bernstein, Matt A
2018-03-01
Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second-order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth-order or B 0 ) and linear (first-order) spatial dependence. This work demonstrates a general solution to eliminate the zeroth-order concomitant field by applying the correct B 0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo-planar imaging (EPI), and fast spin-echo imaging. A global phase offset is reduced in the phase-contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase-encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast-spin echo images. A user-transparent method to compensate the zeroth-order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences-both product and research-to be retained without any modifications. Magn Reson Med 79:1538-1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Chang, Q.; Hren, M. T.; Lin, A. T.; Eley, Y.; Yu, S. W.; Harris, G.
2017-12-01
We present new leaf wax n-alkane hydrogen (δD) and carbon (δ13C) isotopic data from a 36-m-long core from off-shore southwestern Taiwan to evaluate late Quaternary changes in climate and the source of organic matter exported from the landscape. The core (MD178-3291) is located on the flank of the Gaoping Submarine Canyon that connects with the Gaoping river catchment in southwestern Taiwan. The sediment deposition in this core spans the last 26 kyr, providing a unique record of glacial-interglacial changes in organic matter export from the Taiwan orogen. The δD and δ13C both show a shift in isotopic compositions at 15 kyr, that coincides with the shift in planktonic foraminifera δ18O record from the same core as well as the global sea level. We therefore interpret this dominant shift as affected by the global glacial to interglacial transition. Following by this transition and through the interglacial period, both biomarker δD and δ13C data record fluctuations that we suggest result from short timescale changes in the distribution of organic inputs to the offshore site. This change in source is most likely caused by increases in storm and landslide frequency or intensity during warmer intervals. This interpretation is supported by terrestrial records that show an increase in landslides in the Gaoping catchment and evidence for enhanced rainfall intensity and a corresponding increase in the frequency of turbidity currents.
Accurate formulas for interaction force and energy in frequency modulation force spectroscopy
NASA Astrophysics Data System (ADS)
Sader, John E.; Jarvis, Suzanne P.
2004-03-01
Frequency modulation atomic force microscopy utilizes the change in resonant frequency of a cantilever to detect variations in the interaction force between cantilever tip and sample. While a simple relation exists enabling the frequency shift to be determined for a given force law, the required complementary inverse relation does not exist for arbitrary oscillation amplitudes of the cantilever. In this letter we address this problem and present simple yet accurate formulas that enable the interaction force and energy to be determined directly from the measured frequency shift. These formulas are valid for any oscillation amplitude and interaction force, and are therefore of widespread applicability in frequency modulation dynamic force spectroscopy.
Upadhyay, Ganesh; Devi, Th Gomti; Singh, Ranjan K; Singh, A; Alapati, P R
2013-05-15
The isotropic and anisotropic Raman peak frequencies of S=O stretching mode of Dimethyl sulfoxide (DMSO) have been discussed in different chemical and isotopic solvent molecules using different mechanisms. The shifting of peak frequency in further dilution of DMSO with solvent molecule is observed for all solvents. Transition dipole - transition dipole interaction and hydrogen bonding may play a major role in shifting of peak frequencies. The non-coincidence effect (NCE) of DMSO was determined for all the solvents and compared with four theoretical models such as McHale's model, Mirone's modification of McHale's model, Logan's model and Onsager-Fröhlich dielectric continuum model respectively. Most of the theoretical models are largely consistent with our experimental data. Copyright © 2013. Published by Elsevier B.V.
Charge-state dynamics in electrostatic force spectroscopy
NASA Astrophysics Data System (ADS)
Ondráček, Martin; Hapala, Prokop; Jelínek, Pavel
2016-07-01
We present a numerical model that allows us to study the response of an oscillating probe in electrostatic force spectroscopy to charge switching in quantum dots at various time scales. The model provides more insight into the behavior of frequency shift and dissipated energy under different scanning conditions when measuring a temporarily charged quantum dot on a surface. Namely, we analyze the dependence of the frequency shift, the dissipated energy, and their fluctuations on the resonance frequency of the tip and on the electron tunneling rates across the tip-quantum dot and quantum dot-sample junctions. We discuss two complementary approaches to simulating the charge dynamics, a stochastic and a deterministic one. In addition, we derive analytic formulas valid for small amplitudes, describing relations between the frequency shift, dissipated energy, and the characteristic rates driving the charging and discharging processes.
Performance Investigation of Millimeter Wave Generation Reliant on Stimulated Brillouin Scattering
NASA Astrophysics Data System (ADS)
Tickoo, Sheetal; Gupta, Amit
2018-04-01
In this work, photonic method of generating the millimeter waves has been done based on Brillouin scattering effect in optical fiber. Here different approaches are proposed to get maximum frequency shift in mm-wave region using only pumps, radio signals with Mach-Zehnder modulator. Moreover for generated signal validation, signals modulated and send to both wired and wireless medium in optical domain. It is observed that maximum shift of 300 GHz is realized using 60 GHz input sine wave. Basically a frequency doubler is proposed which double shift of input frequency and provide better SNR. For the future generation network system, the generation of millimeter waves makes them well reliable for the transmission of the data.
Waves and instabilities in an anisotropic universe
NASA Astrophysics Data System (ADS)
Papadopoulos, D.; Vlahos, L.; Esposito, F. P.
2002-01-01
The excitation of low frequency plasma waves in an expanding anisotropic cosmological model that contains a magnetic field frozen into the matter and pointing in the longitudinal direction is discussed. Using the exact equations governing finite-amplitude wave propagation in hydromagnetic media within the framework of the general theory of relativity, we show that a spectrum of magnetized sound waves will be excited and form large-scale ``damped oscillations'' in the expanding universe. The characteristic frequency of the excited waves is slightly shifted away from the sound frequency and the shift depends on the strength of the primordial magnetic field. This magnetic field dependent shift may have an effect on the acoustic peaks of the CMB.
Salicylate-induced changes in auditory thresholds of adolescent and adult rats.
Brennan, J F; Brown, C A; Jastreboff, P J
1996-01-01
Shifts in auditory intensity thresholds after salicylate administration were examined in postweanling and adult pigmented rats at frequencies ranging from 1 to 35 kHz. A total of 132 subjects from both age levels were tested under two-way active avoidance or one-way active avoidance paradigms. Estimated thresholds were inferred from behavioral responses to presentations of descending and ascending series of intensities for each test frequency value. Reliable threshold estimates were found under both avoidance conditioning methods, and compared to controls, subjects at both age levels showed threshold shifts at selective higher frequency values after salicylate injection, and the extent of shifts was related to salicylate dose level.
Comments on Landau damping due to synchrotron frequency spread
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, K.Y.; /Fermilab
2005-01-01
An inductive/space-charge impedance shifts the synchrotron frequency downwards above/below transition, but it is often said that the coherent synchrotron frequency of the bunch is not shifted in the rigid-dipole mode. On the other hand, the incoherent synchrotron frequency due to the sinusoidal rf always spreads in the downward direction. This spread will therefore not be able to cover the coherent synchrotron frequency, implying that there will not be any Landau damping no matter how large the frequency spread is. By studying the dispersion relation, it is shown that the above argument is incorrect, and there will be Landau damping ifmore » there is sufficient frequency spread. The main reason is that the coherent frequency of the rigid-dipole mode will no longer remain unshifted in the presence of a synchrotron frequency spread.« less
Petlevich, Walter J.; Sverdrup, Edward F.
1978-01-01
A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.
Real-Time and High-Resolution 3D Face Measurement via a Smart Active Optical Sensor.
You, Yong; Shen, Yang; Zhang, Guocai; Xing, Xiuwen
2017-03-31
The 3D measuring range and accuracy in traditional active optical sensing, such as Fourier transform profilometry, are influenced by the zero frequency of the captured patterns. The phase-shifting technique is commonly applied to remove the zero component. However, this phase-shifting method must capture several fringe patterns with phase difference, thereby influencing the real-time performance. This study introduces a smart active optical sensor, in which a composite pattern is utilized. The composite pattern efficiently combines several phase-shifting fringes and carrier frequencies. The method can remove zero frequency by using only one pattern. Model face reconstruction and human face measurement were employed to study the validity and feasibility of this method. Results show no distinct decrease in the precision of the novel method unlike the traditional phase-shifting method. The texture mapping technique was utilized to reconstruct a nature-appearance 3D digital face.
Real-Time and High-Resolution 3D Face Measurement via a Smart Active Optical Sensor
You, Yong; Shen, Yang; Zhang, Guocai; Xing, Xiuwen
2017-01-01
The 3D measuring range and accuracy in traditional active optical sensing, such as Fourier transform profilometry, are influenced by the zero frequency of the captured patterns. The phase-shifting technique is commonly applied to remove the zero component. However, this phase-shifting method must capture several fringe patterns with phase difference, thereby influencing the real-time performance. This study introduces a smart active optical sensor, in which a composite pattern is utilized. The composite pattern efficiently combines several phase-shifting fringes and carrier frequencies. The method can remove zero frequency by using only one pattern. Model face reconstruction and human face measurement were employed to study the validity and feasibility of this method. Results show no distinct decrease in the precision of the novel method unlike the traditional phase-shifting method. The texture mapping technique was utilized to reconstruct a nature-appearance 3D digital face. PMID:28362349
On the role of mean flows in Doppler shifted frequencies
NASA Astrophysics Data System (ADS)
Gerkema, Theo; Maas, Leo R. M.; van Haren, Hans
2013-04-01
In the oceanographic literature, the term 'Doppler shift' often features in the context of mean flows and (internal) waves. Closer inspection reveals that the term is in fact used for two different things, which should be carefully distinguished, for their conflation results in incorrect interpretations. One refers to the difference in frequencies measured by two observers, one at a fixed position and one moving with the mean flow. The other definition is the one used in physics, where the frequency measured by an observer is compared to that of the source. In the latter sense, Doppler shifts occur only if the source and observer move with respect to each other; a steady mean flow cannot create a Doppler shift. We rehash the classical theory to straighten out some misconceptions and discuss how wave dispersion affects the classical relations and their application, for example on near-inertial internal waves.
Investigation of BOLD fMRI Resonance Frequency Shifts and Quantitative Susceptibility Changes at 7 T
Bianciardi, Marta; van Gelderen, Peter; Duyn, Jeff H.
2013-01-01
Although blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) experiments of brain activity generally rely on the magnitude of the signal, they also provide frequency information that can be derived from the phase of the signal. However, because of confounding effects of instrumental and physiological origin, BOLD related frequency information is difficult to extract and therefore rarely used. Here, we explored the use of high field (7 T) and dedicated signal processing methods to extract frequency information and use it to quantify and interpret blood oxygenation and blood volume changes. We found that optimized preprocessing improves detection of task-evoked and spontaneous changes in phase signals and resonance frequency shifts over large areas of the cortex with sensitivity comparable to that of magnitude signals. Moreover, our results suggest the feasibility of mapping BOLD quantitative susceptibility changes in at least part of the activated area and its largest draining veins. Comparison with magnitude data suggests that the observed susceptibility changes originate from neuronal activity through induced blood volume and oxygenation changes in pial and intracortical veins. Further, from frequency shifts and susceptibility values, we estimated that, relative to baseline, the fractional oxygen saturation in large vessels increased by 0.02–0.05 during stimulation, which is consistent to previously published estimates. Together, these findings demonstrate that valuable information can be derived from fMRI imaging of BOLD frequency shifts and quantitative susceptibility changes. PMID:23897623
Miller, Brian S.; Leaper, Russell; Calderan, Susannah; Gedamke, Jason
2014-01-01
The song of Antarctic blue whales (Balaenoptera musculus intermedia) comprises repeated, stereotyped, low-frequency calls. Measurements of these calls from recordings spanning many years have revealed a long-term linear decline as well as an intra-annual pattern in tonal frequency. While a number of hypotheses for this long-term decline have been investigated, including changes in population structure, changes in the physical environment, and changes in the behaviour of the whales, there have been relatively few attempts to explain the intra-annual pattern. An additional hypothesis that has not yet been investigated is that differences in the observed frequency from each call are due to the Doppler effect. The assumptions and implications of the Doppler effect on whale song are investigated using 1) vessel-based acoustic recordings of Antarctic blue whales with simultaneous observation of whale movement and 2) long-term acoustic recordings from both the subtropics and Antarctic. Results from vessel-based recordings of Antarctic blue whales indicate that variation in peak-frequency between calls produced by an individual whale was greater than would be expected by the movement of the whale alone. Furthermore, analysis of intra-annual frequency shift at Antarctic recording stations indicates that the Doppler effect is unlikely to fully explain the observations of intra-annual pattern in the frequency of Antarctic blue whale song. However, data do show cyclical changes in frequency in conjunction with season, thus suggesting that there might be a relationship among tonal frequency, body condition, and migration to and from Antarctic feeding grounds. PMID:25229644
Miller, Brian S; Leaper, Russell; Calderan, Susannah; Gedamke, Jason
2014-01-01
The song of Antarctic blue whales (Balaenoptera musculus intermedia) comprises repeated, stereotyped, low-frequency calls. Measurements of these calls from recordings spanning many years have revealed a long-term linear decline as well as an intra-annual pattern in tonal frequency. While a number of hypotheses for this long-term decline have been investigated, including changes in population structure, changes in the physical environment, and changes in the behaviour of the whales, there have been relatively few attempts to explain the intra-annual pattern. An additional hypothesis that has not yet been investigated is that differences in the observed frequency from each call are due to the Doppler effect. The assumptions and implications of the Doppler effect on whale song are investigated using 1) vessel-based acoustic recordings of Antarctic blue whales with simultaneous observation of whale movement and 2) long-term acoustic recordings from both the subtropics and Antarctic. Results from vessel-based recordings of Antarctic blue whales indicate that variation in peak-frequency between calls produced by an individual whale was greater than would be expected by the movement of the whale alone. Furthermore, analysis of intra-annual frequency shift at Antarctic recording stations indicates that the Doppler effect is unlikely to fully explain the observations of intra-annual pattern in the frequency of Antarctic blue whale song. However, data do show cyclical changes in frequency in conjunction with season, thus suggesting that there might be a relationship among tonal frequency, body condition, and migration to and from Antarctic feeding grounds.
Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS
Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru
2016-01-01
The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2–8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied. PMID:27079873
Tailoring noise frequency spectrum to improve NIR determinations.
Xie, Shaofei; Xiang, Bingren; Yu, Liyan; Deng, Haishan
2009-12-15
Near infrared spectroscopy (NIR) contains excessive background noise and weak analytical signals caused by near infrared overtones and combinations. That makes it difficult to achieve quantitative determinations of low concentration samples by NIR. A simple chemometric approach has been established to modify the noise frequency spectrum to improve NIR determinations. The proposed method is to multiply one Savitzky-Golay filtered NIR spectrum with another reference spectrum added with thermal noises before the other Savitzky-Golay filter. Since Savitzky-Golay filter is a kind of low-pass filter and cannot eliminate low frequency components of NIR spectrum, using one step or two consecutive Savitzky-Golay filter procedures cannot improve the determination of NIR greatly. Meanwhile, significant improvement is achieved via the Savitzky-Golay filtered NIR spectrum processed with the multiplication alteration before the other Savitzky-Golay filter. The frequency range of the modified noise spectrum shifts toward higher frequency regime via multiplication operation. So the second Savitzky-Golay filter is able to provide better filtering efficiency to obtain satisfied result. The improvement of NIR determination with tailoring noise frequency spectrum technique was demonstrated by both simulated dataset and two measured NIR spectral datasets. It is expected that noise frequency spectrum technique will be adopted mostly in applications where quantitative determination of low concentration sample is crucial.
Stimulated scattering in Ag nanoparticle colloids
NASA Astrophysics Data System (ADS)
Averyushkin, A. S.; Bulychev, N. A.; Efimkov, V. F.; Erokhin, A. I.; Kazaryan, M. A.; Mikhailov, S. I.; Saraeva, I. N.; Zubarev, I. G.
2017-05-01
A number of features of stimulated thermal Rayleigh scattering (STRS) in pure liquids and nanoparticle solutions are investigated in this work. It is shown that scattering efficiency is not reduced in the case of wide spectral bandwidth pump radiation. It is shown experimentally that the frequency shift of the scattered signal relative to the pump frequency greatly exceeds the theoretical value. It is also shown theoretically that the frequency shift value does not depend on the linewidth of the pump.
Etlinger, S C; Guttmann, G; Bauer, H
1986-07-01
A description of scalp-recorded, spontaneous, cerebral DC-potential shifts is given independent of other variables (shift stereotypy), in relationship to higher frequencies (theta, alpha 1, alpha 2: 4-13 Hz) and as analyzed pairwise across the median sagittal line (Fz, Cz, Pz) separately according to frequency and condition (relaxation and moderate mental load). Spontaneous DC-shifts are shown to behave unpredictably. Whether measured jointly (up to triads) or as dyad and triad context entropy, the frontal DC-shifts are calculated as being random, whereby their definition as such within the context of the Principle Component Analysis is supported by the analysis of longitudinal registrations. Cross-correlation analysis of the cerebral slow potential's relationship to each of the higher frequencies (theta, alpha 1, alpha 2) reveals it to be highly independent, the highest correlation accounting for merely 11% of the common variance, the average being 9% (R congruent to 0.3). By matching the conjoint activity of the DC-potential between Fz-Cz, Cz-Pz, and Fz-Pz to that of theta, alpha 1, alpha 2 at the same paired sites, the DC-activity is shown to be operating at higher levels of synchronous activity than the higher frequencies, regardless of pairing and/or condition, although the general level of synchronous activity (DC, theta, alpha 1, alpha 2) is remarkably high along the median sagittal line, 75% of the correlation averages of all analysis-pairings being above 0.60.
NASA Technical Reports Server (NTRS)
Xiong, Fuqin; Andro, Monty
2001-01-01
This paper first shows that the Doppler frequency shift affects the frequencies of the RF carrier, subcarriers, envelope, and symbol timing by the same percentage in an Orthogonal Frequency Division Multiplexing (OFDM) signal or any other modulated signals. Then the SNR degradation of an OFDM system due to Doppler frequency shift, frequency offset of the local oscillators and phase noise is analyzed. Expressions are given and values for 4-, 16-, 64-, and 256-QAM OFDM systems are calculated and plotted. The calculations show that the Doppler shift of the D3 project is about 305 kHz, and the degradation due to it is about 0.01 to 0.04 dB, which is negligible. The degradation due to frequency offset and phase noise of local oscillators will be the main source of degradation. To keep the SNR degradation under 0.1 dB, the relative frequency offset due to local oscillators must be below 0.01 for the 16 QAM-OFDM. This translates to an offset of 1.55 MHz (0.01 x 155 MHz) or a stability of 77.5 ppm (0.01 x 155 MHz/20 GHz) for the DI project. To keep the SNR degradation under 0.1 dB, the relative linewidth (0) due to phase noise of the local oscillators must be below 0.0004 for the 16 QAM-OFDM. This translates to a linewidth of 0.062 MHz (0.0004 x 155 MHz) of the 20 GHz RIF carrier. For a degradation of 1 dB, beta = 0.04, and the linewidth can be relaxed to 6.2 MHz.
Bernstein wave aided laser third harmonic generation in a plasma
NASA Astrophysics Data System (ADS)
Tyagi, Yachna; Tripathi, Deepak; Kumar, Ashok
2016-09-01
The process of Bernstein wave aided resonant third harmonic generation of laser in a magnetized plasma is investigated. The extra-ordinary mode (X-mode) laser of frequency ω 0 and wave number k → 0 , travelling across the magnetic field in a plasma, exerts a second harmonic ponderomotive force on the electrons imparting them an oscillatory velocity v → 2 ω0 , 2 k → 0 . This velocity beats with the density perturbation due to the Bernstein wave to produce a density perturbation at cyclotron frequency shifted second harmonic. The density perturbation couples with the oscillatory velocity v → ω0 , k → 0 of X-mode of the laser to produce the cyclotron frequency shifted third harmonic current density leading to harmonic radiation. The phase matching condition for the up shifted frequency is satisfied when the Bernstein wave is nearly counter-propagating to the laser. As the transverse wave number of the Bernstein wave is large, it is effective in the phase matched third harmonic generation, when the laser frequency is not too far from the upper hybrid frequency.
Goodman, Shawn S; Keefe, Douglas H
2006-06-01
Otoacoustic emissions serve as a noninvasive probe of the medial olivocochlear (MOC) reflex. Stimulus frequency otoacoustic emissions (SFOAEs) elicited by a low-level probe tone may be the optimal type of emission for studying MOC effects because at low levels, the probe itself does not elicit the MOC reflex [Guinan et al. (2003) J. Assoc. Res. Otolaryngol. 4:521]. Based on anatomical considerations, the MOC reflex activated by ipsilateral acoustic stimulation (mediated by the crossed olivocochlear bundle) is predicted to be stronger than the reflex to contralateral stimulation. Broadband noise is an effective activator of the MOC reflex; however, it is also an effective activator of the middle-ear muscle (MEM) reflex, which can make results difficult to interpret. The MEM reflex may be activated at lower levels than measured clinically, and most previous human studies have not explicitly included measurements to rule out MEM reflex contamination. The current study addressed these issues using a higher-frequency SFOAE probe tone to test for cochlear changes mediated by the MOC reflex, while simultaneously monitoring the MEM reflex using a low-frequency probe tone. Broadband notched noise was presented ipsilaterally at various levels to elicit probe-tone shifts. Measurements are reported for 15 normal-hearing subjects. With the higher-frequency probe near 1.5 kHz, only 20% of subjects showed shifts consistent with an MOC reflex in the absence of an MEM-induced shift. With the higher-frequency probe near 3.5 kHz, up to 40% of subjects showed shifts in the absence of an MEM-induced shift. However, these responses had longer time courses than expected for MOC-induced shifts, and may have been dominated by other cochlear processes, rather than MOC reflex. These results suggest caution in the interpretation of effects observed using ipsilaterally presented acoustic activators intended to excite the MOC reflex.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baeßler, S.; Nesvizhevsky, V. V.; Pignol, G.
Quantum states of ultracold neutrons in a gravitational field are characterized through gravitational resonance spectroscopy. This paper discusses systematic effects that appear in the spectroscopic measurements. The discussed frequency shifts-which we call the Stern-Gerlach shift, interference shift, and spectator-state shift-appear in conceivable measurement schemes and have general importance. Lastly, these shifts have to be taken into account in precision experiments.
Vibratory Adaptation of Cutaneous Mechanoreceptive Afferents
Bensmaïa, S. J.; Leung, Y. Y.; Hsiao, S. S.; Johnson, K. O.
2007-01-01
The objective of this study was to investigate the effects of extended suprathreshold vibratory stimulation on the sensitivity of slowly adapting type 1 (SA1), rapidly adapting (RA), and Pacinian (PC) afferents. To that end, an algorithm was developed to track afferent absolute (I0) and entrainment (I1) thresholds as they change over time. We recorded afferent responses to periliminal vibratory test stimuli, which were interleaved with intense vibratory conditioning stimuli during the adaptation period of each experimental run. From these measurements, the algorithm allowed us to infer changes in the afferents’ sensitivity. We investigated the stimulus parameters that affect adaptation by assessing the degree to which adaptation depends on the amplitude and frequency of the adapting stimulus. For all three afferent types, I0 and I1 increased with increasing adaptation frequency and amplitude. The degree of adaptation seems to be independent of the firing rate evoked in the afferent by the conditioning stimulus. In the analysis, we distinguished between additive adaptation (in which I0 and I1 shift equally) and multiplicative effects (in which the ratio I1/I0 remains constant). RA threshold shifts are almost perfectly additive. SA1 threshold shifts are close to additive and far from multiplicative (I1 threshold shifts are twice the shifts). PC shifts are more difficult to classify. We used an I0 integrate-and-fire model to study the possible neural mechanisms. A change in transducer gain predicts a multiplicative change in I0 and I1 and is thus ruled out as a mechanism underlying SA1 and RA adaptation. A change in the resting action potential threshold predicts equal, additive change in I0 and I1 and thus accounts well for RA adaptation. A change in the degree of refractoriness during the relative refractory period predicts an additional change in I1 such as that observed for SA1 fibers. We infer that adaptation is caused by an increase in spiking thresholds produced by ion flow through transducer channels in the receptor membrane. In a companion paper, we describe the time-course of vibratory adaptation and recovery for SA1, RA, and PC fibers. PMID:16014802
Changes in Quadriceps Muscle Activity During Sustained Recreational Alpine Skiing
Kröll, Josef; Müller, Erich; Seifert, John G.; Wakeling, James M.
2011-01-01
During a day of skiing thousands of repeated contractions take place. Previous research on prolonged recreational alpine skiing show that physiological changes occur and hence some level of fatigue is inevitable. In the present paper the effect of prolonged skiing on the recruitment and coordination of the muscle activity was investigated. Six subjects performed 24 standardized runs. Muscle activity during the first two (PREskiing) and the last two (POSTskiing) runs was measured from the vastus lateralis (VL) and rectus femoris (RF) using EMG and quantified using wavelet and principal component analysis. The frequency content of the EMG signal shifted in seven out of eight cases significantly towards lower frequencies with highest effects observed for RF on outside leg. A significant pronounced outside leg loading occurred during POSTskiing and the timing of muscle activity peaks occurred more towards turn completion. Specific EMG frequency changes were observed at certain time points throughout the time windows and not over the whole double turn. It is suggested that general muscular fatigue, where additional specific muscle fibers have to be recruited due to the reduced power output of other fibers did not occur. The EMG frequency decrease and intensity changes for RF and VL are caused by altered timing (coordination) within the turn towards a most likely more uncontrolled skiing technique. Hence, these data provide evidence to suggest recreational skiers alter their skiing technique before a potential change in muscle fiber recruitment occurs. Key points The frequency content of the EMG signal shifted in seven out of eight cases significantly towards lower frequencies with highest effects observed for RF. General muscular fatigue, where additional specific fibers have to be recruited due to the reduced power output of other fibers, did not occur. A modified skiing style towards a less functional and hence more uncontrolled skiing technique seems to be a key issue with respect to the influence on muscle recruitment for applied prolonged skiing session. PMID:24149299
Miniature Piezoelectric Macro-Mass Balance
NASA Technical Reports Server (NTRS)
Sherrit, Stewart; Trebi-Ollennu, Ashitey; Bonitz, Robert G.; Bar-Cohen, Yoseph
2010-01-01
Mass balances usually use a strain gauge that requires an impedance measurement and is susceptible to noise and thermal drift. A piezoelectric balance can be used to measure mass directly by monitoring the voltage developed across the piezoelectric balance, which is linear with weight or it can be used in resonance to produce a frequency change proportional to the mass change (see figure). The piezoelectric actuator/balance is swept in frequency through its fundamental resonance. If a small mass is added to the balance, the resonance frequency shifts down in proportion to the mass. By monitoring the frequency shift, the mass can be determined. This design allows for two independent measurements of mass. Additionally, more than one sample can be verified because this invention allows for each sample to be transported away from the measuring device upon completion of the measurement, if required. A piezoelectric actuator, or many piezoelectric actuators, was placed between the collection plate of the sampling system and the support structure. As the sample mass is added to the plate, the piezoelectrics are stressed, causing them to produce a voltage that is proportional to the mass and acceleration. In addition, a change in mass delta m produces a change in the resonance frequency with delta f proportional to delta m. In a microgravity environment, the spacecraft could be accelerated to produce a force on the piezoelectric actuator that would produce a voltage proportional to the mass and acceleration. Alternatively, the acceleration could be used to force the mass on the plate, and the inertial effects of the mass on the plate would produce a shift in the resonance frequency with the change in frequency related to the mass change. Three prototypes of the mass balance mechanism were developed. These macro-mass balances each consist of a solid base and an APA 60 Cedrat flextensional piezoelectric actuator supporting a measuring plate. A similar structure with 3 APA 120 Cedrat flextensional piezoelectric actuators spaced equidistantly at 120 degrees supporting the plate and a softer macro balance with an APA 150 actuator/sensor were developed. These flextensional actuators were chosen because they increase the sensitivity of the actuator to stress, allow the piezoelectric to be pre-stressed, and the piezoelectric element is a stacked multilayer actuator, which has a considerably lower input impedance than a monolithic element that allows for common instruments (e.g., input impedance of 10 megohms) to measure the voltage without rapidly discharging the charge/voltage on the piezoelectric actuator.
NASA Astrophysics Data System (ADS)
Zhu, Zihang; Zhao, Shanghong; Li, Xuan; Qu, Kun; Lin, Tao
2018-01-01
A photonic approach to generate frequency-doubled microwave waveforms using an integrated dual-polarization quadrature phase shift keying (DP-QPSK) modulator driven by a sinusoidal radio frequency (RF) signal is proposed. By adjusting the dc bias points of the DP-QPSK modulator, the obtained second-order and six-order harmonics are in phase while the fourth-order harmonics are complementary when the orthogonal polarized outputs of the modulator are photodetected. After properly setting the modulation indices of the modulator, the amplitude of the second-order harmonic is 9 times of that of the six-order harmonic, indicating a frequency-doubled triangular waveform is generated. If a broadband 90° microwave phase shifter is attached after the photodetector (PD) to introduce a 90° phase shift, a frequency-doubled square waveform can be obtained after adjusting the amplitude of the second-order harmonic 3 times of that of the six-order harmonic. The proposal is first theoretically analyzed and then validated by simulation. Simulation results show that a 10 GHz triangular and square waveform sequences are successfully generated from a 5 GHz sinusoidal RF drive signal.
Describing-function analysis of a ripple regulator with slew-rate limits and time delays
NASA Technical Reports Server (NTRS)
Wester, Gene W.
1990-01-01
The effects of time delays and slew-rate limits on the steady-state operating points and performance of a free-running ripple regulator are evaluated using describing-function analysis. The describing function of an ideal comparator (no time delays or slew rate limits) has no phase shift and is independent of frequency. It is found that turn-on delay and turn-off delay have different effects on gain and phase and cannot be combined. Comparator hysteresis affects both gain and phase; likewise, time delays generally affect both gain and phase. It is found that the effective time delay around the feedback loop is one half the sum of turn-on and turn-off delays, regardless of whether the delays are caused by storage time or slew rate limits. Expressions are formulated for the switching frequency, switch duty ratio, dc output, and output ripple. For the case of no hysteresis, a simple, graphical solution for the switching frequency is possible, and the resulting switching frequency is independent of first-order variations of input or load.
Nordbeck, Peter; Ritter, Oliver; Weiss, Ingo; Warmuth, Marcus; Gensler, Daniel; Burkard, Natalie; Herold, Volker; Jakob, Peter M; Ertl, Georg; Ladd, Mark E; Quick, Harald H; Bauer, Wolfgang R
2011-01-01
Implanted medical devices such as cardiac pacemakers pose a potential hazard in magnetic resonance imaging. Electromagnetic fields have been shown to cause severe radio frequency-induced tissue heating in some cases. Imaging exclusion zones have been proposed as an instrument to reduce patient risk. The purpose of this study was to further assess the impact of the imaging landmark on the risk for unintended implant heating by measuring the radio frequency-induced electric fields in a body phantom under several imaging conditions at 1.5T. The results show that global radio frequency-induced coupling is highest with the torso centered along the superior-inferior direction of the transmit coil. The induced E-fields inside the body shift when changing body positioning, reducing both global and local radio frequency coupling if body and/or conductive implant are moved out from the transmit coil center along the z-direction. Adequate selection of magnetic resonance imaging landmark can significantly reduce potential hazards in patients with implanted medical devices. © 2010 Wiley-Liss, Inc.
The dynamics of genetic draft in rapidly adapting populations.
Kosheleva, Katya; Desai, Michael M
2013-11-01
The accumulation of beneficial mutations on competing genetic backgrounds in rapidly adapting populations has a striking impact on evolutionary dynamics. This effect, known as clonal interference, causes erratic fluctuations in the frequencies of observed mutations, randomizes the fixation times of successful mutations, and leaves distinct signatures on patterns of genetic variation. Here, we show how this form of "genetic draft" affects the forward-time dynamics of site frequencies in rapidly adapting asexual populations. We calculate the probability that mutations at individual sites shift in frequency over a characteristic timescale, extending Gillespie's original model of draft to the case where many strongly selected beneficial mutations segregate simultaneously. We then derive the sojourn time of mutant alleles, the expected fixation time of successful mutants, and the site frequency spectrum of beneficial and neutral mutations. Finally, we show how this form of draft affects inferences in the McDonald-Kreitman test and how it relates to recent observations that some aspects of genetic diversity are described by the Bolthausen-Sznitman coalescent in the limit of very rapid adaptation.
Yu, Yinan; Wang, Yicheng; Pratt, Jon R
2016-03-01
Residual amplitude modulation (RAM) is one of the most common noise sources known to degrade the sensitivity of frequency modulation spectroscopy. RAM can arise as a result of the temperature dependent birefringence of the modulator crystal, which causes the orientation of the crystal's optical axis to shift with respect to the polarization of the incident light with temperature. In the fiber-based optical interferometer used on the National Institute of Standards and Technology calculable capacitor, RAM degrades the measured laser frequency stability and correlates with the environmental temperature fluctuations. We have demonstrated a simple approach that cancels out excessive RAM due to polarization mismatch between the light and the optical axis of the crystal. The approach allows us to measure the frequency noise of a heterodyne beat between two lasers individually locked to different resonant modes of a cavity with an accuracy better than 0.5 ppm, which meets the requirement to further determine the longitudinal mode number of the cavity length. Also, this approach has substantially mitigated the temperature dependency of the measurements of the cavity length and consequently the capacitance.
Multipath interference test method for distributed amplifiers
NASA Astrophysics Data System (ADS)
Okada, Takahiro; Aida, Kazuo
2005-12-01
A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.
Dai, Chenkai; Cheng, Tao; Wood, Mark W.; Gan, Rong Z.
2007-01-01
The aim of this study is to investigate the function of the superior malleolar ligament (SML) and the anterior malleolar ligament (AML) in human middle ear for sound transmission through simulations of fixation and detachment of these ligaments in human temporal bones and a finite element (FE) ear model. Two laser vibrometers were used to measure the vibrations of the tympanic membrane (TM) and stapes footplate. A 3-D FE ear model was used to predict the transfer function of the middle ear with ligament fixation and detachment. The results demonstrate that fixations and detachments of the SML and AML had different effects on TM and stapes footplate movements. Fixation of the SML resulted in a reduction of displacement of the TM (umbo) and the footplate at low frequencies (f < 1000 Hz), but also caused a shift of displacement peak to higher frequencies. Fixation of both SML and AML caused a reduction of 15 dB at umbo or stapes at low frequencies. Detachment of the SML had almost no effect on TM and footplate mobility, but AML detachment had a minor effect on TM and footplate movement. The FE model was able to predict the effects of SML and AML fixation and detachment. PMID:17517484
NASA Technical Reports Server (NTRS)
Hazra, Rajeeb; Viles, Charles L.; Park, Stephen K.; Reichenbach, Stephen E.; Sieracki, Michael E.
1992-01-01
Consideration is given to a model-based method for estimating the spatial frequency response of a digital-imaging system (e.g., a CCD camera) that is modeled as a linear, shift-invariant image acquisition subsystem that is cascaded with a linear, shift-variant sampling subsystem. The method characterizes the 2D frequency response of the image acquisition subsystem to beyond the Nyquist frequency by accounting explicitly for insufficient sampling and the sample-scene phase. Results for simulated systems and a real CCD-based epifluorescence microscopy system are presented to demonstrate the accuracy of the method.
NASA Astrophysics Data System (ADS)
Asemi, H. R.; Asemi, S. R.; Farajpour, A.; Mohammadi, M.
2015-04-01
The potential applications of piezoelectric nanofilms (PNFs) and double-piezoelectric-nanofilm (DPNF) systems as nanoelectromechanical mass sensors are examined. The PNFs carrying multiple nanoparticles at arbitrary locations are modeled as rectangular nonlocal plates with attached concentrated masses. Using the nonlocal elasticity theory and Hamilton's principle, the differential equations of motion are derived for both PNF-based and DPNF-based nanosensors. The influences of small scale, initial stress and temperature change on the frequency shifts of the nanoelectromechanical sensors are taken into consideration. Explicit expressions are derived for the resonance frequencies of the nanosensors by employing the Galerkin method. The present results show that when the value of nonlocal parameter decreases, the frequency shifts of piezoelectric nanosensors increase. Further, the frequency shifts of DPNF-based mass sensors are always greater than those of PNF-based mass sensors. The present work would be helpful in the design of nanoelectromechanical mass sensors using PNFs.
The Complex Nature of Bilinguals' Language Usage Modulates Task-Switching Outcomes
Yang, Hwajin; Hartanto, Andree; Yang, Sujin
2016-01-01
In view of inconsistent findings regarding bilingual advantages in executive functions (EF), we reviewed the literature to determine whether bilinguals' different language usage causes measureable changes in the shifting aspects of EF. By drawing on the theoretical framework of the adaptive control hypothesis—which postulates a critical link between bilinguals' varying demands on language control and adaptive cognitive control (Green and Abutalebi, 2013), we examined three factors that characterize bilinguals' language-switching experience: (a) the interactional context of conversational exchanges, (b) frequency of language switching, and (c) typology of code-switching. We also examined whether methodological variations in previous task-switching studies modulate task-specific demands on control processing and lead to inconsistencies in the literature. Our review demonstrates that not only methodological rigor but also a more finely grained, theory-based approach will be required to understand the cognitive consequences of bilinguals' varied linguistic practices in shifting EF. PMID:27199800
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parkin, William M.; Balan, Adrian; Liang, Liangbo
Here, we report how the presence of electron-beam-induced sulfur vacancies affects first-order Raman modes and correlate the effects with the evolution of the in situ transmission-electron microscopy (TEM) two-terminal conductivity of monolayer MoS 2 under electron irradiation. We observe a redshift in the E Raman peak and a less pronounced blueshift in the A' 1 peak with increasing electron dose. Using energy-dispersive X-ray spectroscopy (EDS), we show that irradiation causes partial removal of sulfur and correlate the dependence of the Raman peak shifts with S vacancy density (a few %), which is confirmed by first-principles density functional theory calculations. Inmore » situ device current measurements show exponential decrease in channel current upon irradiation. Our analysis demonstrates that the observed frequency shifts are intrinsic properties of the defective systems and that Raman spectroscopy can be used as a quantitative diagnostic tool to characterize MoS 2-based transport channels.« less
NASA Astrophysics Data System (ADS)
Pagán, Brianna; Ashfaq, Moetasim; Nayak, Munir; Rastogi, Deeksha; Margulis, Steven; Pal, Jeremy
2017-04-01
The Western United States shares limited snowmelt driven water supplies amongst millions of people, a multi-billion dollar agriculture industry and fragile ecosystems. The climatology of the region is highly variable, characterized by the frequent occurrences of both flood and drought conditions that cause increasingly challenging water management issues. Although variable year to year, up to half of California's total precipitation can be linked to atmospheric rivers (ARs). Most notably, ARs have been connected to nearly every major historic flood in the region, establishing its critical role to water supply. Numerous prior studies have considered potential climate change impacts over the Western United States and have generally concluded that warmer temperatures will reduce snowpack and shift runoff timing, causing reductions to water supply. Here we examine the role of ARs as one mechanism for explaining projected increases in flood and drought frequency and intensity under climate change scenarios, vital information for water resource managers. A hierarchical modeling framework to downscale 11 coupled global climate models from CMIP5 is used to form an ensemble of high-resolution dynamically downscaled regional climate model (via RegCM4) simulations at 18-km and hydrological (via VIC) simulations at a 4-km resolution for baseline (1965-2005) and future (2010-2050) periods under RCP 8.5. Each ensemble member's ability to capture observational AR climatology over the baseline period is evaluated. Baseline to future period changes to AR size, duration, seasonal timing, trajectory, magnitude and frequency are presented. These changes to the characterizations of ARs in the region are used to determine if any links exist to changes in snowpack volume, runoff timing, and the occurrence of daily and annual cumulative extreme precipitation and runoff events. Shifts in extreme AR frequency and magnitude are expected to increase flood risks, which without adequate multi-year reservoir storage solutions could further strain water supply resources.
Raman spectra of Nd/Sn cosubstituted Ba6-3xSm8+2xTi18O54 microwave dielectric ceramics
NASA Astrophysics Data System (ADS)
Wu, S. Y.; Li, Y.; Chen, X. M.
2004-11-01
The Raman spectra and dielectric properties of Nd /Sn cosubstituted Ba6-3xSm8+2xTi18O54 (x =2/3) microwave dielectric ceramics were discussed as the functions of composition and sintering time. The peaks in 753cm-1 were caused by the second order scatter. The peaks in 425 and 403cm-1 became sharper with prolonging sintering time, and this reflected the increased lattice defects. The shoulder peak near 292cm-1 was caused by the octahedral tilt when A site is Nd3+. The Raman shifts in 590, 520, 280, and 232cm-1 indicated no obvious change in position, but all peaks became sharper with prolonging sintering time. This indicated the increased ordering degree of A-site cations. With prolonging sintering time, the Qf factor (Q is the inverse of dielectric loss, tan δ, and f is the resonant frequency) increased, and the temperature coefficient of resonant frequency significantly decreased or became more negative, while the dielectric constant indicated no significant variation.
NASA Astrophysics Data System (ADS)
Yoshinaga, Tsukasa; Nozaki, Kazunori; Wada, Shigeo
2018-03-01
The sound generation mechanisms of sibilant fricatives were investigated with experimental measurements and large-eddy simulations using a simplified vocal tract model. The vocal tract geometry was simplified to a three-dimensional rectangular channel, and differences in the geometries while pronouncing fricatives /s/ and /∫/ were expressed by shifting the position of the tongue and its constricted flow channel. Experimental results showed that the characteristic peak frequency of the fricatives decreased when the distance between the tongue and teeth increased. Numerical simulations revealed that the jet flow generated from the constriction impinged on the upper teeth wall and caused the main sound source upstream and downstream from the gap between the teeth. While magnitudes of the sound source decreased with increments of the frequency, amplitudes of the pressure downstream from the constriction increased at the peak frequencies of the corresponding tongue position. These results indicate that the sound pressures at the peak frequencies increased by acoustic resonance in the channel downstream from the constriction, and the different frequency characteristics between /s/ and /∫/ were produced by changing the constriction and the acoustic node positions inside the vocal tract.
Iodine absorption cells quality evaluation methods
NASA Astrophysics Data System (ADS)
Hrabina, Jan; Zucco, Massimo; Holá, Miroslava; Šarbort, Martin; Acef, Ouali; Du-Burck, Frédéric; Lazar, Josef; Číp, Ondřej
2016-12-01
The absorption cells represent an unique tool for the laser frequency stabilization. They serve as irreplaceable optical frequency references in realization of high-stable laser standards and laser sources for different brands of optical measurements, including the most precise frequency and dimensional measurement systems. One of the most often used absorption media covering visible and near IR spectral range is molecular iodine. It offers rich atlas of very strong and narrow spectral transitions which allow realization of laser systems with ultimate frequency stabilities in or below 10-14 order level. One of the most often disccussed disadvantage of the iodine cells is iodine's corrosivity and sensitivity to presence of foreign substances. The impurities react with absorption media and cause spectral shifts of absorption spectra, spectral broadening of the transitions and decrease achievable signal-to-noise ratio of the detected spectra. All of these unwanted effects directly influence frequency stability of the realized laser standard and due to this fact, the quality of iodine cells must be precisely controlled. We present a comparison of traditionally used method of laser induced fluorescence (LIF) with novel technique based on hyperfine transitions linewidths measurement. The results summarize advantages and drawbacks of these techniques and give a recommendation for their practical usage.
A method of eliminating hydrogen maser wall shift
NASA Technical Reports Server (NTRS)
Levine, M. W.; Vessot, R. F. C.
1972-01-01
Maser output frequency shift was prevented by storage bulb kept at temperature at which wall shift is zero and effects of bulb size, shape, and surface texture are eliminated. Servo system is shown, along with bidirectional counter.
Shen, Dazhong; Kang, Qi; Li, Xiaoyu; Cai, Hongmei; Wang, Yuandong
2007-06-19
This paper presents different experimental results of the influence of an immersion angle (theta, the angle between the surface of a quartz crystal resonator and the horizon) on the resonant frequency of a quartz crystal microbalance (QCM) sensor exposed one side of its sensing surfaces to liquid. The experimental results show that the immersion angle is an added factor that may influence the frequency of the QCM sensor. This type of influence is caused by variation of the reflection conditions of the longitudinal wave between the QCM sensor and the walls of the detection cell. The frequency shifts, measured by varying theta, are related to the QCM sensor used. When a QCM sensor with a weak longitudinal wave is used, its resonant frequency is nearly independent of theta. But, if a QCM sensor with a strong longitudinal wave is employed, the immersion angle is a potential error source for the measurements performed on the QCM sensor. When the reflection conditions of the longitudinal wave are reduced, the influence of theta on the resonant frequency of the QCM sensor is negligible. The slope of the plot of frequency shifts (deltaF) versus (rho eta)(1/2), the square root of the product of solution density (rho) and viscosity (eta), may be influenced by theta in a single experiment for the QCM sensor with a strong longitudinal wave in low viscous liquids, which can however, be effectively weakened by using the averaged values of reduplicated experiments. In solutions with a large (rho eta)(1/2) region (0-55 wt% sucrose solution as an example, with rho value from 1.00 to 1.26 g cm(-3) and eta value from 0.01 to 0.22 g cm(-1) s(-1), respectively), the slope of the plot of deltaF versus (rho eta)(1/2) is independent of theta even for the QCM sensor with a strong longitudinal wave in a single experiment. The influence of theta on the resonant frequency of the QCM sensor should be taken into consideration in its applications in liquid phase.
Hyperfine frequencies of {sup 87}Rb and {sup 133}Cs atoms in Xe gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGuyer, B. H.; Xia, T.; Jau, Y.-Y.
2011-09-15
The microwave resonant frequencies of ground-state {sup 87}Rb and {sup 133}Cs atoms in Xe buffer gas are shown to have a relatively large nonlinear dependence on the Xe pressure, presumably because of RbXe or CsXe van der Waals molecules. The nonlinear shifts for Xe are opposite in sign to the previously measured shifts for Ar and Kr, even though all three gases have negative linear shifts. The Xe data show striking discrepancies with the previous theory for nonlinear shifts. Most of this discrepancy is eliminated by accounting for the spin-rotation interaction, {gamma}N{center_dot}S, in addition to the hyperfine-shift interaction, {delta} Amore » I{center_dot}S, in the molecules. To the limit of our experimental accuracy, the shifts of {sup 87}Rb and {sup 133}Cs in He, Ne, and N{sub 2} were linear with pressure.« less
NASA Astrophysics Data System (ADS)
Zhang, Ruiying; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2013-08-01
We propose a method for photoacoustic flow measurement based on the Doppler effect from a flowing homogeneous medium. Excited by spatially modulated laser pulses, the flowing medium induces a Doppler frequency shift in the received photoacoustic signals. The frequency shift is proportional to the component of the flow speed projected onto the acoustic beam axis, and the sign of the shift reflects the flow direction. Unlike conventional flowmetry, this method does not rely on particle heterogeneity in the medium; thus, it can tolerate extremely high particle density. A red-ink phantom flowing in a tube immersed in water was used to validate the method in both the frequency and time domains. The phantom flow immersed in an intralipid solution was also measured.
NASA Astrophysics Data System (ADS)
Liu, Wenliang; Wang, Xiaofeng; Wu, Jizhou; Su, Xingliang; Wang, Shen; Sovkov, Vladimir B.; Ma, Jie; Xiao, Liantuan; Jia, Suotang
2017-08-01
We report on the experimental observation and quantitative determination of the laser-induced frequency shift (LIFS) of the ultracold polar molecules formed by photoassociation (PA). The experiments are performed by detecting a series of double PA spectra with a molecular hyperfine structure, which are induced by two PA lasers with a precise and adjustable frequency reference. We find that the LIFS of the molecular hyperfine levels shows a linear dependence on PA laser intensity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Han-Chun; Ye, Tianyu; Mani, R. G.
2015-02-14
Linear polarization angle, θ, dependent measurements of the microwave radiation-induced oscillatory magnetoresistance, R{sub xx}, in high mobility GaAs/AlGaAs 2D electron devices have shown a θ dependence in the oscillatory amplitude along with magnetic field, frequency, and extrema-dependent phase shifts, θ{sub 0}. Here, we suggest a microwave frequency dependence of θ{sub 0}(f) using an analysis that averages over other smaller contributions, when those contributions are smaller than estimates of the experimental uncertainty.
Two Azimuthally Separated Regions of Cusp Ion Injection Observed via Energetic Neutral Atoms
NASA Technical Reports Server (NTRS)
Abe, M.; Taguchi, S.; Collier, M. R.; Moore, T. E.
2011-01-01
The low-energy neutral atom (LENA) imager on the IMAGE spacecraft can detect energetic neutral atoms produced by ion injection into the cusp through a charge exchange with the Earth's hydrogen exosphere. We examined the occurrence of the LENA cusp signal during positive IMF B(sub z) in terms of the arrival direction and the IMF clock angle theta(sub CA). Results of statistical analyses show that the occurrence frequency is high on the postnoon side when theta(sub CA) is between approximately 20 degrees and approximately 50 degrees. This is ascribed to ion injection caused by cusp reconnection typical of positive IMF B(sub z). Our results also show that there is another situation of high occurrence frequency, which can be identified with theta(sub CA) of approximately 30 degrees to approximately 80 degrees. When theta(sub CA) is relatively large (60 degrees - 80 degrees), occurrence frequencies are high at relatively low latitudes over a wide extent spanning both prenoon and postnoon sectors. This feature suggests that the ion injection is caused by reconnection at the dayside magnetopause. Its postnoon side boundary shifts toward the prenoon as theta(sub CA) decreases. When theta(sub CA) is less than approximately 50 degrees, the high occurrence frequency exists well inside the prenoon sector, which is azimuthally separated from the postnoon region ascribed to cusp reconnection. The prenoon region, which is thought due to ion injection caused by dayside reconnection, may explain the recent report that proton aurora brightening occurs in the unanticipated prenoon sector of the northern high-latitude ionosphere for IMF B(sub y) greater than 0 and B(sub z) greater than 0.
Cardillo, Marcel; Weston, Peter H; Reynolds, Zoe K M; Olde, Peter M; Mast, Austin R; Lemmon, Emily M; Lemmon, Alan R; Bromham, Lindell
2017-08-01
The frequency of evolutionary biome shifts during diversification has important implications for our ability to explain geographic patterns of plant diversity. Recent studies present several examples of biome shifts, but whether frequencies of biome shifts closely reflect geographic proximity or environmental similarity of biomes remains poorly known. We explore this question by using phylogenomic methods to estimate the phylogeny of Hakea, a diverse Australian genus occupying a wide range of biomes. Model-based estimation of ancestral regions indicates that Hakea began diversifying in the Mediterranean biome of southern Australia in the Middle Eocene-Early Oligocene, and dispersed repeatedly into other biomes across the continent. We infer around 47 shifts between biomes. Frequencies of shifts between pairs of biomes are usually similar to those expected from their geographic connectedness or climatic similarity, but in some cases are substantially higher or lower than expected, perhaps reflecting how readily key physiological traits can be modified to adapt lineages to new environments. The history of frequent biome-shifting is reflected in the structure of present-day assemblages, which tend to be more phylogenetically diverse than null-model expectations. The case of Hakea demonstrates that the radiation of large plant clades across wide geographic areas need not be constrained by dispersal limitation or conserved adaptations to particular environments. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.
Matrix isolation infrared spectra of hydrogen halide and halogen complexes with nitrosyl halides
NASA Technical Reports Server (NTRS)
Allamandola, Louis J.; Lucas, Donald; Pimentel, George C.
1982-01-01
Matrix isolation infrared spectra of nitrosyl halide (XNO) complexes with HX and X2 (X = Cl, Br) are presented. The relative frequency shifts of the HX mode are modest (ClNO H-Cl, delta-nu/nu = -0.045; BrNO H-Br, delta-nu/nu = -0.026), indicating weak hydrogen bonds 1-3 kcal/mol. These shifts are accompanied by significant shifts to higher frequencies in the XN-O stretching mode (CIN-O HCl, delta-nu/nu = +0.016; BrN-O HBr, delta-nu/nu = +0.011). Similar shifts were observed for the XN-O X2 complexes (ClN-O Cl2, delta-nu/nu = +0.009; BrN-O-Br2, delta-nu/nu = +0.013). In all four complexes, the X-NO stretching mode relative shift is opposite in sign and about 1.6 times that of the NO stretching mode. These four complexes are considered to be similar in structure and charge distribution. The XN-O frequency shift suggests that complex formation is accompanied by charge withdrawal from the NO bond ranging from about .04 to .07 electron charges. The HX and X2 molecules act as electron acceptors, drawing electrons out of the antibonding orbital of NO and strengthening the XN-O bond. The implications of the pattern of vibrational shifts concerning the structure of the complexes are discussed.
Simulation of ultrasonic focus aberration and correction through human tissue.
Tabei, Makoto; Mast, T Douglas; Waag, Robert C
2003-02-01
Ultrasonic focusing in two dimensions has been investigated by calculating the propagation of ultrasonic pulses through cross-sectional models of human abdominal wall and breast. Propagation calculations used a full-wave k-space method that accounts for spatial variations in density, sound speed, and frequency-dependent absorption and includes perfectly matched layer absorbing boundary conditions. To obtain a distorted receive wavefront, propagation from a point source through the tissue path was computed. Receive focusing used an angular spectrum method. Transmit focusing was accomplished by propagating a pressure wavefront from a virtual array through the tissue path. As well as uncompensated focusing, focusing that employed time-shift compensation and time-shift compensation after backpropagation was investigated in both transmit and receive and time reversal was investigated for transmit focusing in addition. The results indicate, consistent with measurements, that breast causes greater focus degradation than abdominal wall. The investigated compensation methods corrected the receive focus better than the transmit focus. Time-shift compensation after backpropagation improved the focus from that obtained using time-shift compensation alone but the improvement was less in transmit focusing than in receive focusing. Transmit focusing by time reversal resulted in lower sidelobes but larger mainlobes than the other investigated transmit focus compensation methods.
Automatic alignment of individual peaks in large high-resolution spectral data sets
NASA Astrophysics Data System (ADS)
Stoyanova, Radka; Nicholls, Andrew W.; Nicholson, Jeremy K.; Lindon, John C.; Brown, Truman R.
2004-10-01
Pattern recognition techniques are effective tools for reducing the information contained in large spectral data sets to a much smaller number of significant features which can then be used to make interpretations about the chemical or biochemical system under study. Often the effectiveness of such approaches is impeded by experimental and instrument induced variations in the position, phase, and line width of the spectral peaks. Although characterizing the cause and magnitude of these fluctuations could be important in its own right (pH-induced NMR chemical shift changes, for example) in general they obscure the process of pattern discovery. One major area of application is the use of large databases of 1H NMR spectra of biofluids such as urine for investigating perturbations in metabolic profiles caused by drugs or disease, a process now termed metabonomics. Frequency shifts of individual peaks are the dominant source of such unwanted variations in this type of data. In this paper, an automatic procedure for aligning the individual peaks in the data set is described and evaluated. The proposed method will be vital for the efficient and automatic analysis of large metabonomic data sets and should also be applicable to other types of data.
Frequency-shift detectors bind binaural as well as monaural frequency representations.
Carcagno, Samuele; Semal, Catherine; Demany, Laurent
2011-12-01
Previous psychophysical work provided evidence for the existence of automatic frequency-shift detectors (FSDs) that establish perceptual links between successive sounds. In this study, we investigated the characteristics of the FSDs with respect to the binaural system. Listeners were presented with sound sequences consisting of a chord of pure tones followed by a single test tone. Two tasks were performed. In the "present/absent" task, the test tone was either identical to one of the chord components or positioned halfway in frequency between two components, and listeners had to discriminate between these two possibilities. In the "up/down" task, the test tone was slightly different in frequency from one of the chord components and listeners had to identify the direction (up or down) of the corresponding shift. When the test tone was a pure tone presented monaurally, either to the same ear as the chord or to the opposite ear, listeners performed the up/down task better than the present/absent task. This paradoxical advantage for directional frequency shifts, providing evidence for FSDs, persisted when the test tone was replaced by a dichotic stimulus consisting of noise but evoking a pitch sensation as a consequence of binaural processing. Performance in the up/down task was similar for the dichotic stimulus and for a monaural narrow-band noise matched in pitch salience to it. Our results indicate that the FSDs are insensitive to sound localization mechanisms and operate on central frequency representations, at or above the level of convergence of the monaural auditory pathways.
Dynamic Metasurface Aperture as Smart Around-the-Corner Motion Detector.
Del Hougne, Philipp; F Imani, Mohammadreza; Sleasman, Timothy; Gollub, Jonah N; Fink, Mathias; Lerosey, Geoffroy; Smith, David R
2018-04-25
Detecting and analysing motion is a key feature of Smart Homes and the connected sensor vision they embrace. At present, most motion sensors operate in line-of-sight Doppler shift schemes. Here, we propose an alternative approach suitable for indoor environments, which effectively constitute disordered cavities for radio frequency (RF) waves; we exploit the fundamental sensitivity of modes of such cavities to perturbations, caused here by moving objects. We establish experimentally three key features of our proposed system: (i) ability to capture the temporal variations of motion and discern information such as periodicity ("smart"), (ii) non line-of-sight motion detection, and (iii) single-frequency operation. Moreover, we explain theoretically and demonstrate experimentally that the use of dynamic metasurface apertures can substantially enhance the performance of RF motion detection. Potential applications include accurately detecting human presence and monitoring inhabitants' vital signs.
Nazarov, V E; Kolpakov, A B; Radostin, A V
2012-07-01
The results of experimental and theoretical studies of low-frequency nonlinear acoustics phenomena (amplitude-dependent loss, resonance frequency shifts, and a generation of second and third harmonics) in a magnesite rod resonator are presented. Acceleration and velocity oscillograms of vibrations of the free boundary of the resonator caused by harmonic excitations were measured and analyzed. A theoretical description of the observed amplitude dependences was carried out within the framework of the phenomenological state equations that contain either of the two types of hysteretic nonlinearity (elastic and inelastic). The type of hysteresis and parameters of acoustic nonlinearity of magnesite were established from comparing the experimental measurements with the theoretical dependences. The values of the parameters were anomalously high even when compared to those of other strongly nonlinear polycrystalline materials such as granite, marble, limestone, sandstone, etc.
Twagirayezu, Sylvestre; Cich, Matthew J.; Sears, Trevor J.; ...
2015-07-14
Doppler-free transition frequencies for v₄₋ and v₅₋excited hot bands have been measured in the v₁ + v₃ band region of the spectrum of acetylene using saturation dip spectroscopy with an extended cavity diode laser referenced to a frequency comb. The frequency accuracy of the measured transitions, as judged from line shape model fits and comparison to known frequencies in the v₁ + v₃ band itself, is between 3 and 22 kHz. This is some three orders of magnitude improvement on the accuracy and precision of previous line position estimates that were derived from the analysis of high-resolution Fourier transform infraredmore » absorption spectra. Comparison to transition frequencies computed from constants derived from published Fourier transform infrared spectra shows that some upper rotational energy levels suffer specific perturbations causing energy level shifts of up to several hundred MHz. These perturbations are due to energy levels of the same rotational quantum number derived from nearby vibrational levels that become degenerate at specific energies. Future identification of the perturbing levels will provide accurate relative energies of excited vibrational levels of acetylene in the 7100–7600 cm⁻¹ energy region.« less
Time-frequency analysis of phonocardiogram signals using wavelet transform: a comparative study.
Ergen, Burhan; Tatar, Yetkin; Gulcur, Halil Ozcan
2012-01-01
Analysis of phonocardiogram (PCG) signals provides a non-invasive means to determine the abnormalities caused by cardiovascular system pathology. In general, time-frequency representation (TFR) methods are used to study the PCG signal because it is one of the non-stationary bio-signals. The continuous wavelet transform (CWT) is especially suitable for the analysis of non-stationary signals and to obtain the TFR, due to its high resolution, both in time and in frequency and has recently become a favourite tool. It decomposes a signal in terms of elementary contributions called wavelets, which are shifted and dilated copies of a fixed mother wavelet function, and yields a joint TFR. Although the basic characteristics of the wavelets are similar, each type of the wavelets produces a different TFR. In this study, eight real types of the most known wavelets are examined on typical PCG signals indicating heart abnormalities in order to determine the best wavelet to obtain a reliable TFR. For this purpose, the wavelet energy and frequency spectrum estimations based on the CWT and the spectra of the chosen wavelets were compared with the energy distribution and the autoregressive frequency spectra in order to determine the most suitable wavelet. The results show that Morlet wavelet is the most reliable wavelet for the time-frequency analysis of PCG signals.
Measurement of temperature changes in cooling dead rats using magnetic resonance thermometry.
Kuribayashi, Hideto; Cui, Fanlai; Hirakawa, Keiko; Kanawaku, Yoshimasa; Ohno, Youkichi
2011-11-01
Magnetic resonance imaging thermometry has been introduced as a technique for measurement of temperature changes in cooling dead rats. Rat pelvic magnetic resonance images were acquired sequentially more than 2h after euthanasia by halothane overdose. A series of temperature difference maps in cooling dead rats was obtained with calculating imaging phase changes induced by the water proton frequency shift caused by temperature changes. Different cooling processes were monitored by the temperature difference maps in the rats. Magnetic resonance imaging thermometry applied in the study of laboratory animals could theoretically reproduce a variety of causes of death with different environmental conditions. Outcomes from experimental animal studies could be translated into a temperature-based time of death estimation in forensics. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
A frequency-stabilized light source at 399 nm using an Yb hollow-cathode lamp
NASA Astrophysics Data System (ADS)
Tanabe, Takehiko; Akamatsu, Daisuke; Inaba, Hajime; Okubo, Sho; Kobayashi, Takumi; Yasuda, Masami; Hosaka, Kazumoto; Hong, Feng-Lei
2018-06-01
We demonstrate a diode laser system operating at 399 nm that is stabilized to the 6s2 1S0–6s6p 1P1 electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached 1.1 × 10‑11 at an averaging time of τ = 1 s. We performed an absolute frequency measurement using an optical frequency comb and determined that the absolute frequency of the laser stabilized to the 1S0–1P1 transition in 174Yb was 751 526 522.26(9) MHz. We also investigated several systematic frequency shifts while changing some of the light source parameters and measured several isotope shifts. The measured laser frequency will provide useful information regarding the practical use of the frequency-stabilized light source at 399 nm.
Velocity measurement by vibro-acoustic Doppler.
Nabavizadeh, Alireza; Urban, Matthew W; Kinnick, Randall R; Fatemi, Mostafa
2012-04-01
We describe the theoretical principles of a new Doppler method, which uses the acoustic response of a moving object to a highly localized dynamic radiation force of the ultrasound field to calculate the velocity of the moving object according to Doppler frequency shift. This method, named vibro-acoustic Doppler (VAD), employs two ultrasound beams separated by a slight frequency difference, Δf, transmitting in an X-focal configuration. Both ultrasound beams experience a frequency shift because of the moving objects and their interaction at the joint focal zone produces an acoustic frequency shift occurring around the low-frequency (Δf) acoustic emission signal. The acoustic emission field resulting from the vibration of the moving object is detected and used to calculate its velocity. We report the formula that describes the relation between Doppler frequency shift of the emitted acoustic field and the velocity of the moving object. To verify the theory, we used a string phantom. We also tested our method by measuring fluid velocity in a tube. The results show that the error calculated for both string and fluid velocities is less than 9.1%. Our theory shows that in the worst case, the error is 0.54% for a 25° angle variation for the VAD method compared with an error of -82.6% for a 25° angle variation for a conventional continuous wave Doppler method. An advantage of this method is that, unlike conventional Doppler, it is not sensitive to angles between the ultrasound beams and direction of motion.
Brunstrom, J M; Roberts, B
2001-07-01
When a partial of a periodic complex is mistuned, its change in pitch is greater than expected. Two experiments examined whether these partial-pitch shifts are related to the computation of global pitch. In experiment 1, stimuli were either harmonic or frequency-shifted (25% of F0) complexes. One partial was mistuned by +/- 4% and played with leading and lagging portions of 500 ms each, relative to the other components (1 s), in both monaural and dichotic contexts. Subjects indicated whether the mistuned partial was higher or lower in pitch when concurrent with the other components. Responses were positively correlated with the direction of mistuning in all conditions. In experiment 2, stimuli from each condition were compared with synchronous equivalents. Subjects matched a pure tone to the pitch of the mistuned partial (component 4). The results showed that partial-pitch shifts are not reduced in size by asynchrony. Similar asynchronies are known to produce a near-exclusion of a mistuned partial from the global-pitch computation. This mismatch indicates that global and partial pitch are derived from different processes. The similarity of the partial-pitch shifts observed for harmonic and frequency-shifted stimuli suggests that they arise from a grouping mechanism that is sensitive to spectral regularity.
Transverse Mode Coupling Instability of the Bunch with Oscillating Wake Field and Space Charge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balbekov, V.
Transverse mode coupling instability of a single bunch caused by oscillating wake field is considered in the paper. The instability threshold is found at different frequencies of the wake with space charge tune shift taken into account. The wake phase advance in the bunch length from 0 up tomore » $$4\\pi$$ is investigated. It is shown that the space charge can push the instability threshold up or down dependent on the phase advance. Transition region is investigated thoroughly, and simple asymptotic formulas for the threshold are represented.« less
Dielectric dispersion studies of some potentised homeopathic medicines reveal structured vehicle.
Mahata, C R
2013-10-01
Avogadro's Number gives 12c as the limit beyond which no original substance can be present in a highly diluted and succcussed (potentised) homeopathic medicine, implying that chemically such dilutions consist of nothing but the vehicle. But there is evidence that living systems react to homeopathic medicines diluted even above 12c. To explain how such medicines differ from another I hypothesise that altered structure may cause the difference, such as that between diamond and amorphous carbon. Some scientists have argued that dilution followed by succussion may lead to altered structural arrangement of water molecules. This concept may be termed 'Induced Molecular Structure'. Dielectric dispersion studies were conducted in a broad range with potencies below and above the Avogadro limit by taking 6c and 30c potencies of Graphites and Cuprum Metallicum in liquid form. Measurements were made with an Anomalous Dielectric Dispersion Detector (A3D), an instrument developed by the author. Experiments were carried out in a frequency range of 100 kHz to 50 MHz. Shifting of resonance frequencies as a function of medicine and potency, with potencies below and above the Avogadro limit, was observed. The range of resonance frequencies suggest that the phenomenon might originate from oscillation of dipoles caused by electric field in variously structured and polarised water. Also, there is reasonable evidence that frequencies change with materials and potency. Copyright © 2013 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.
FIBER AND INTEGRATED OPTICS: Radio-frequency electrooptic modulation in optical fibers
NASA Astrophysics Data System (ADS)
Bulyuk, A. N.
1992-10-01
The electrooptic interaction in single-mode optical fibers with both linear and circular birefringe is analyzed. In most cases, a large interaction length imposes a limit on the modulation frequency. A circular birefringence in an optical fiber may lead to an effective coupling of polarization normal modes if a phase-matching condition is satisfied. Through an appropriate choice of polarization states of the light at the entrance and exit of the device, one can achieve a polarization modulation or a frequency shift of the light. There are possible applications in rf polarization modulators, devices for shifting the frequency of light, and detectors of electromagnetic fields.
Method and apparatus for measuring frequency and phase difference
NASA Technical Reports Server (NTRS)
Shores, Paul (Inventor); Lichtenberg, Christopher (Inventor); Kobayashi, Herbert S. (Inventor); Cunningham, Allen R. (Inventor)
1986-01-01
The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.
Optical frequency standards for gravitational wave detection using satellite velocimetry
NASA Astrophysics Data System (ADS)
Vutha, Amar
2015-04-01
Satellite Doppler velocimetry, building on the work of Kaufmann and Estabrook and Wahlquist, is a complementary technique to interferometric methods of gravitational wave detection. This method is based on the fact that the gravitational wave amplitude appears in the apparent Doppler shift of photons propagating from an emitter to a receiver. This apparent Doppler shift can be resolved provided that a frequency standard, capable of quickly averaging down to a high stability, is available. We present a design for a space-capable optical atomic frequency standard, and analyze the sensitivity of satellite Doppler velocimetry for gravitational wave astronomy in the milli-hertz frequency band.
NASA Astrophysics Data System (ADS)
Abdulsamad, Feras; Florsch, Nicolas; Schmutz, Myriam; Camerlynck, Christian
2016-12-01
During the last decades, the usage of spectral induced polarization (SIP) measurements in hydrogeology and detecting environmental problems has been extensively increased. However, the physical mechanisms which are responsible for the induced polarization response over the usual frequency range (typically 1 mHz to 10-20 kHz) require better understanding. The phase shift observed at high frequencies is sometimes attributed to the so-called Maxwell-Wagner polarization which takes place when charges cross an interface. However, SIP measurements of tap water show a phase shift at frequencies higher than 1 kHz, where no Maxwell-Wagner polarization may occur. In this paper, we enlighten the possible origin of this phase shift and deduce its likely relationship with the types of the measuring electrodes. SIP Laboratory measurements of tap water using different types of measuring electrodes (polarizable and non-polarizable electrodes) are carried out to detect the origin of the phase shift at high frequencies and the influence of the measuring electrodes types on the observed complex resistivity. Sodium chloride is used to change the conductivity of the medium in order to quantify the solution conductivity role. The results of these measurements are clearly showing the impact of the measuring electrodes type on the measured phase spectrum while the influence on the amplitude spectrum is negligible. The phenomenon appearing on the phase spectrum at high frequency (> 1 kHz) whatever the electrode type is, the phase shows an increase compared to the theoretical response, and the discrepancy (at least in absolute value) increases with frequency, but it is less severe when medium conductivity is larger. Additionally, the frequency corner is shifted upward in frequency. The dependence of this phenomenon on the conductivity and the measuring electrodes type (electrode-electrolyte interface) seems to be due to some dielectric effects (as an electrical double layer of small relaxation time formed at the electrodes interface). Therefore, this dielectric response should be taken into account at high frequency to better analytically separate the medium own response from that linked to the measuring electrodes used. We modeled this effect by adding a capacitance connected in parallel with the traditional equivalent electric circuit used to describe the dielectric response of medium.
Uchida, Yoshiko; Urade, Yoshihiro; Mori, Seiji; Kohzuma, Takamitsu
2010-03-01
The Mg(2+) ion-assisted activation mechanism of the active site Tyr8 of a human hematopoietic prostaglandin D(2) synthase (H-PGDS) was studied by ultraviolet resonance Raman (UVRR) spectroscopy. Addition of Mg(2+) to the native H-PGDS at pH 8.0 resulted in the Y8a Raman band of Tyr8 shifting from 1615cm(-1) to 1600cm(-1). This large shift to lower energy of the tyrosine Y8a vibrational mode is caused by the deprotonation of the tyrosine phenol group promoted by binding of Mg(2+). Upon subsequent addition of glutathione (GSH), the Mg(2+)/H-PGDS solution showed the Tyr8 Raman band shifted to 1611cm(-1), which is 11cm(-1) higher than the frequency of the Mg(2+) complex of H-PGDS, but 4cm(-1) lower than the Mg(2+) free enzyme. These UVRR observations suggest that the deprotonated Tyr8 in the presence of Mg(2+) is re-protonated by the abstraction of H(+) from the thiol group of GSH, and that the re-protonated Tyr8 species forms a hydrogen bond with the thiolate anion of GSH. Density functional theory calculations on several model complexes of p-cresol were also performed, which suggested that the pK(a) and vibrational frequencies of the Tyr8 phenol group are affected by the degree and structure of hydration of the Tyr8 residue. Copyright 2009 Elsevier Inc. All rights reserved.
Coupling of conservative and dissipative forces in frequency-modulation atomic force microscopy
NASA Astrophysics Data System (ADS)
Sader, John E.; Jarvis, Suzanne P.
2006-11-01
Frequency modulation atomic force microscopy (FM-AFM) utilizes the principle of self-excitation to ensure the cantilever probe vibrates at its resonant frequency, regardless of the tip-sample interaction. Practically, this is achieved by fixing the phase difference between tip deflection and driving force at precisely 90° . This, in turn, decouples the frequency shift and excitation amplitude signals, enabling quantitative interpretation in terms of conservative and dissipative tip-sample interaction forces. In this article, we theoretically investigate the effect of phase detuning in the self-excitation mechanism on the coupling between conservative and dissipative forces in FM-AFM. We find that this coupling depends only on the relative difference in the drive and resonant frequencies far from the surface, and is thus very weakly dependent on the actual phase error particularly for high quality factors. This establishes that FM-AFM is highly robust with respect to phase detuning, and enables quantitative interpretation of the measured frequency shift and excitation amplitude, even while operating away from the resonant frequency with the use of appropriate replacements in the existing formalism. We also examine the calibration of phase shifts in FM-AFM measurements and demonstrate that the commonly used approach of minimizing the excitation amplitude can lead to significant phase detuning, particularly in liquid environments.
Early signs of recovery of Acropora palmata in St. John, US Virgin Islands
Muller, E.M.; Rogers, Caroline S.; van Woesik, R.
2014-01-01
Since the 1980s, diseases have caused significant declines in the population of the threatened Caribbean coral Acropora palmata. Yet it is largely unknown whether the population densities have recovered from these declines and whether there have been any recent shifts in size-frequency distributions toward large colonies. It is also unknown whether colony size influences the risk of disease infection, the most common stressor affecting this species. To address these unknowns, we examined A. palmata colonies at ten sites around St. John, US Virgin Islands, in 2004 and 2010. The prevalence of white-pox disease was highly variable among sites, ranging from 0 to 53 %, and this disease preferentially targeted large colonies. We found that colony density did not significantly change over the 6-year period, although six out of ten sites showed higher densities through time. The size-frequency distributions of coral colonies at all sites were positively skewed in both 2004 and 2010, however, most sites showed a temporal shift toward more large-sized colonies. This increase in large-sized colonies occurred despite the presence of white-pox disease, a severe bleaching event, and several storms. This study provides evidence of slow recovery of the A. palmata population around St. John despite the persistence of several stressors.
Origin of the OH vibrational blue shift in the LiOH crystal.
Hermansson, Kersti; Gajewski, Grzegorz; Mitev, Pavlin D
2008-12-25
The O-H vibrational frequency in crystalline hydroxides is either upshifted or downshifted by its crystalline surroundings. In the LiOH crystal, the experimental gas-to-solid O-H frequency upshift ("blue shift") is approximately +115 cm(-1). Here plane-wave DFT calculations for the isotope-isolated LiOH crystal have been performed and we discuss the origin of the OH frequency upshift, and the nature of the OH group and the interlayer interactions. We find that (1) the vibrational frequency upshift originates from interactions within the LiOH layer; this OH upshift is slightly lessened by the interlayer interactions; (2) the interlayer O-H - - - H-O interaction is largely electrostatic in character (but there is no hydrogen bonding); (3) the gas-to-solid vibrational shift for OH in LiOH(s) and its subsystems qualitatively adheres to a parabola-like "frequency vs electric field strength" correlation curve, which has a maximum for a positive electric field, akin to the correlation curve earlier found in the literature for an isolated OH(-) ion in an electric field.
Microstrip patch antenna for simultaneous strain and temperature sensing
NASA Astrophysics Data System (ADS)
Mbanya Tchafa, F.; Huang, H.
2018-06-01
A patch antenna, consisting of a radiation patch, a dielectric substrate, and a ground plane, resonates at distinct fundamental frequencies that depend on the substrate dielectric constant and the dimensions of the radiation patch. Since these parameters change with the applied strain and temperature, this study investigates simultaneous strain and temperature sensing using a single antenna that has two fundamental resonant frequencies. The theoretical relationship between the antenna resonant frequency shifts, the temperature, and the applied strain was first established to guide the selection of the dielectric substrate, based on which an antenna sensor with a rectangular radiation patch was designed and fabricated. A tensile test specimen instrumented with the antenna sensor was subjected to thermo-mechanical tests. Experiment results validated the theoretical predictions that the normalized antenna resonant frequency shifts are linearly proportional to the applied strain and temperature changes. An inverse method was developed to determine the strain and temperature changes from the normalized antenna resonant frequency shifts, yielding measurement uncertainty of 0.4 °C and 17.22 μ \\varepsilon for temperature and strain measurement, respectively.
Zheng, Hanrong; Fang, Zujie; Wang, Zhaoyong; Lu, Bin; Cao, Yulong; Ye, Qing; Qu, Ronghui; Cai, Haiwen
2018-01-31
It is a basic task in Brillouin distributed fiber sensors to extract the peak frequency of the scattering spectrum, since the peak frequency shift gives information on the fiber temperature and strain changes. Because of high-level noise, quadratic fitting is often used in the data processing. Formulas of the dependence of the minimum detectable Brillouin frequency shift (BFS) on the signal-to-noise ratio (SNR) and frequency step have been presented in publications, but in different expressions. A detailed deduction of new formulas of BFS variance and its average is given in this paper, showing especially their dependences on the data range used in fitting, including its length and its center respective to the real spectral peak. The theoretical analyses are experimentally verified. It is shown that the center of the data range has a direct impact on the accuracy of the extracted BFS. We propose and demonstrate an iterative fitting method to mitigate such effects and improve the accuracy of BFS measurement. The different expressions of BFS variances presented in previous papers are explained and discussed.
Seven, Yasin B.; Mantilla, Carlos B.; Zhan, Wen-Zhi; Sieck, Gary C.
2012-01-01
We hypothesized that diaphragm muscle (DIAm) by a shift in the EMG power spectral density (PSD) to higher frequencies reflects recruitment of more fatigable fast-twitch motor units and motor unit recruitment is reflected by EMG non-stationarity. DIAm EMG was recorded in anesthetized rats during eupnea, hypoxia-hypercapnia (10% O2-5% CO2), airway occlusion, and sneezing (maximal DIAm force). Although power in all frequency bands increased progressively across motor behaviors, PSD centroid frequency increased only during sneezing (p<0.05). The non-stationary period at the onset of EMG activity ranged from ~70 ms during airway occlusion to ~150 ms during eupnea. Within the initial non-stationary period of EMG activity 80–95% of motor units were recruited during different motor behaviors. Motor units augmented their discharge frequencies progressively beyond the non-stationary period; yet, EMG signal became stationary. In conclusion, non-stationarity of DIAm EMG reflects the period of motor unit recruitment, while a shift in the PSD towards higher frequencies reflects recruitment of more fatigable fast-twitch motor units. PMID:22986086
Discrimination of rippled-spectrum patterns in noise: A manifestation of compressive nonlinearity
Milekhina, Olga N.; Nechaev, Dmitry I.; Klishin, Vladimir O.
2017-01-01
In normal-hearing listeners, rippled-spectrum discrimination was psychophysically investigated in both silence and with a simultaneous masker background using the following two paradigms: measuring the ripple density resolution with the phase-reversal test and measuring the ripple-shift threshold with the ripple-shift test. The 0.5-oct wide signal was centered on 2 kHz, the signal levels were 50 and 80 dB SPL, and the masker levels varied from 30 to 100 dB SPL. The baseline ripple density resolutions were 8.7 oct-1 and 8.6 oct-1 for the 50-dB and 80-dB signals, respectively. The baseline ripple shift thresholds were 0.015 oct and 0.018 oct for the 50-dB and 80-dB signals, respectively. The maskers were 0.5-oct noises centered on 2 kHz (on-frequency) or 0.75 to 1.25 oct below the signal (off-frequency maskers). The effects of the maskers were as follows: (i) both on- and low-frequency maskers reduced the ripple density resolution and increased the ripple shift thresholds, (ii) the masker levels at threshold (the ripple density resolution decrease down to 3 oct–1 or ripple shift threshold increased up to 0.1 oct) increased with increasing frequency spacing between the signal and masker, (iii) the masker levels at threshold were higher for the 80-dB signal than for the 50-dB signal, and (iv) the difference between the masker levels at threshold for the 50-dB and 80-dB signals decreased with increasing frequency spacing between the masker and signal. Within the 30-dB (from 50 to 80 dB SPL) signal level, the growth of the masker level at threshold was 27.8 dB for the on-frequency masker and 9 dB for the low-frequency masker. It is assumed that the difference between the on- and low-frequency masking of the rippled-spectrum discrimination reflects the cochlear compressive non-linearity. With this assumption, the compression was 0.3 dB/dB. PMID:28346538
The time course of spoken word learning and recognition: studies with artificial lexicons.
Magnuson, James S; Tanenhaus, Michael K; Aslin, Richard N; Dahan, Delphine
2003-06-01
The time course of spoken word recognition depends largely on the frequencies of a word and its competitors, or neighbors (similar-sounding words). However, variability in natural lexicons makes systematic analysis of frequency and neighbor similarity difficult. Artificial lexicons were used to achieve precise control over word frequency and phonological similarity. Eye tracking provided time course measures of lexical activation and competition (during spoken instructions to perform visually guided tasks) both during and after word learning, as a function of word frequency, neighbor type, and neighbor frequency. Apparent shifts from holistic to incremental competitor effects were observed in adults and neural network simulations, suggesting such shifts reflect general properties of learning rather than changes in the nature of lexical representations.
Konorov, S O; Akimov, D A; Zheltikov, A M; Ivanov, A A; Alfimov, M V; Scalora, M
2005-06-15
Femtosecond pulses of fundamental Cr:forsterite laser radiation are used as a pump field to tune the frequency of copropagating second-harmonic pulses of the same laser through cross-phase modulation in a photonic crystal fiber. Sub-100-kW femtosecond pump pulses coupled into a photonic crystal fiber with an appropriate dispersion profile can shift the central frequency of the probe field by more than 100 nm, suggesting a convenient way to control propagation and spectral transformations of ultrashort laser pulses.
Time Shifted PN Codes for CW Lidar, Radar, and Sonar
NASA Technical Reports Server (NTRS)
Campbell, Joel F. (Inventor); Prasad, Narasimha S. (Inventor); Harrison, Fenton W. (Inventor); Flood, Michael A. (Inventor)
2013-01-01
A continuous wave Light Detection and Ranging (CW LiDAR) system utilizes two or more laser frequencies and time or range shifted pseudorandom noise (PN) codes to discriminate between the laser frequencies. The performance of these codes can be improved by subtracting out the bias before processing. The CW LiDAR system may be mounted to an artificial satellite orbiting the earth, and the relative strength of the return signal for each frequency can be utilized to determine the concentration of selected gases or other substances in the atmosphere.
Jüschke, M; Koch, C; Dreyer, T
2014-09-01
The efficiency of ultrasonic cleaning vessels cannot be measured directly in an easy way. In the presented work, a sensor is developed which quantitatively measures the ablation of a test layer. The sensor element is a quartz crystal which is coated with a sacrificial layer. Small changes in mass of this layer can be measured by a frequency shift of the crystal oscillation. For measurements, a 10 MHz AT-cut quartz crystal was used in a cleaning vessel working at 44.9 kHz. To determine the frequency shift by the ablation of the test layer, the quartz crystal was driven by a frequency generator sweeping the frequency in the range of the resonance frequency and a characteristic frequency was determined. The test layer which was applied to the quartz crystal consisted of silica microparticles suspended in varnish. In a preliminary experiment using a commercial cleaner it could be shown that significant changes in resonance frequency by cavitation effect could be detected. The initial frequency shift of the sacrificial layer is reproducible within 10%. The test layer can be adapted to the conditions of the cleaning vessel. By changing the electrical input power of the vessel, a threshold in the cavitation erosion was found. Copyright © 2014 Elsevier B.V. All rights reserved.
Raanan, Dekel; Ren, Liqing; Oron, Dan; Silberberg, Yaron
2018-02-01
Stimulated Raman scattering (SRS) has recently become useful for chemically selective bioimaging. It is usually measured via modulation transfer from the pump beam to the Stokes beam. Impulsive stimulated Raman spectroscopy, on the other hand, relies on the spectral shift of ultrashort pulses as they propagate in a Raman active sample. This method was considered impractical with low energy pulses since the observed shifts are very small compared to the excitation pulse bandwidth, spanning many terahertz. Here we present a new apparatus, using tools borrowed from the field of precision measurement, for the detection of low-frequency Raman lines via stimulated-Raman-scattering-induced spectral shifts. This method does not require any spectral filtration and is therefore an excellent candidate to resolve low-lying Raman lines (<200 cm -1 ), which are commonly masked by the strong Rayleigh scattering peak. Having the advantage of the high repetition rate of the ultrafast oscillator, we reduce the noise level by implementing a lock-in detection scheme with a wavelength shift sensitivity well below 100 fm. This is demonstrated by the measurement of low-frequency Raman lines of various liquid samples.
Perceptual adaptation of voice gender discrimination with spectrally shifted vowels.
Li, Tianhao; Fu, Qian-Jie
2011-08-01
To determine whether perceptual adaptation improves voice gender discrimination of spectrally shifted vowels and, if so, which acoustic cues contribute to the improvement. Voice gender discrimination was measured for 10 normal-hearing subjects, during 5 days of adaptation to spectrally shifted vowels, produced by processing the speech of 5 male and 5 female talkers with 16-channel sine-wave vocoders. The subjects were randomly divided into 2 groups; one subjected to 50-Hz, and the other to 200-Hz, temporal envelope cutoff frequencies. No preview or feedback was provided. There was significant adaptation in voice gender discrimination with the 200-Hz cutoff frequency, but significant improvement was observed only for 3 female talkers with F(0) > 180 Hz and 3 male talkers with F(0) < 170 Hz. There was no significant adaptation with the 50-Hz cutoff frequency. Temporal envelope cues are important for voice gender discrimination under spectral shift conditions with perceptual adaptation, but spectral shift may limit the exclusive use of spectral information and/or the use of formant structure on voice gender discrimination. The results have implications for cochlear implant users and for understanding voice gender discrimination.
Perceptual Adaptation of Voice Gender Discrimination with Spectrally Shifted Vowels
Li, Tianhao; Fu, Qian-Jie
2013-01-01
Purpose To determine whether perceptual adaptation improves voice gender discrimination of spectrally shifted vowels and, if so, which acoustic cues contribute to the improvement. Method Voice gender discrimination was measured for 10 normal-hearing subjects, during 5 days of adaptation to spectrally shifted vowels, produced by processing the speech of 5 male and 5 female talkers with 16-channel sine-wave vocoders. The subjects were randomly divided into 2 groups; one subjected to 50-Hz, and the other to 200-Hz, temporal envelope cutoff frequencies. No preview or feedback was provided. Results: There was significant adaptation in voice gender discrimination with the 200-Hz cutoff frequency, but significant improvement was observed only for 3 female talkers with F0 > 180 Hz and 3 male talkers with F0 < 170 Hz. There was no significant adaptation with the 50-Hz cutoff frequency. Conclusions Temporal envelope cues are important for voice gender discrimination under spectral shift conditions with perceptual adaptation, but spectral shift may limit the exclusive use of spectral information and/or the use of formant structure on voice gender discrimination. The results have implications for cochlear implant users and for understanding voice gender discrimination. PMID:21173392
Stimulated concentration (diffusion) light scattering on nanoparticles in a liquid suspension
NASA Astrophysics Data System (ADS)
Burkhanov, I. S.; Krivokhizha, S. V.; Chaikov, L. L.
2016-06-01
A nonlinear growth of the light scattering intensity has been observed and the frequency shift of the spectral line of scattered light has been measured in light backscattered in suspensions of diamond and latex nanoparticles in water. The shift corresponds to the HWHM of the line of spontaneous scattering on particles. We may conclude that there exists stimulated concentration (diffusion) light scattering on variations of the particle concentration, which is also called the stimulated Mie scattering. In a fibre probe scheme, the growth of the shift of the scattered spectral line is observed with an increase in the exciting beam power. The variation of the frequency shift with an increase in the exciting power is explained by convection in liquid.
Broadband one-dimensional photonic crystal wave plate containing single-negative materials.
Chen, Yihang
2010-09-13
The properties of the phase shift of wave reflected from one-dimensional photonic crystals consisting of periodic layers of single-negative (permittivity- or permeability-negative) materials are demonstrated. As the incident angle increases, the reflection phase shift of TE wave decreases, while that of TM wave increases. The phase shifts of both polarized waves vary smoothly as the frequency changes across the photonic crystal stop band. Consequently, the difference between the phase shift of TE and that of TM wave could remain constant in a rather wide frequency range inside the stop band. These properties are useful to design wave plate or retarder which can be used in wide spectral band. In addition, a broadband photonic crystal quarter-wave plate is proposed.
NASA Astrophysics Data System (ADS)
Ibrahim, Dahi Ghareab Abdelsalam; Yasui, Takeshi
2018-04-01
Two-wavelength phase-shift interferometry guided by optical frequency combs is presented. We demonstrate the operation of the setup with a large step sample simultaneously with a resolution test target with a negative pattern. The technique can investigate multi-objects simultaneously with high precision. Using this technique, several important applications in metrology that require high speed and precision are demonstrated.
Applying time-frequency analysis to assess cerebral autoregulation during hypercapnia.
Placek, Michał M; Wachel, Paweł; Iskander, D Robert; Smielewski, Peter; Uryga, Agnieszka; Mielczarek, Arkadiusz; Szczepański, Tomasz A; Kasprowicz, Magdalena
2017-01-01
Classic methods for assessing cerebral autoregulation involve a transfer function analysis performed using the Fourier transform to quantify relationship between fluctuations in arterial blood pressure (ABP) and cerebral blood flow velocity (CBFV). This approach usually assumes the signals and the system to be stationary. Such an presumption is restrictive and may lead to unreliable results. The aim of this study is to present an alternative method that accounts for intrinsic non-stationarity of cerebral autoregulation and the signals used for its assessment. Continuous recording of CBFV, ABP, ECG, and end-tidal CO2 were performed in 50 young volunteers during normocapnia and hypercapnia. Hypercapnia served as a surrogate of the cerebral autoregulation impairment. Fluctuations in ABP, CBFV, and phase shift between them were tested for stationarity using sphericity based test. The Zhao-Atlas-Marks distribution was utilized to estimate the time-frequency coherence (TFCoh) and phase shift (TFPS) between ABP and CBFV in three frequency ranges: 0.02-0.07 Hz (VLF), 0.07-0.20 Hz (LF), and 0.20-0.35 Hz (HF). TFPS was estimated in regions locally validated by statistically justified value of TFCoh. The comparison of TFPS with spectral phase shift determined using transfer function approach was performed. The hypothesis of stationarity for ABP and CBFV fluctuations and the phase shift was rejected. Reduced TFPS was associated with hypercapnia in the VLF and the LF but not in the HF. Spectral phase shift was also decreased during hypercapnia in the VLF and the LF but increased in the HF. Time-frequency method led to lower dispersion of phase estimates than the spectral method, mainly during normocapnia in the VLF and the LF. The time-frequency method performed no worse than the classic one and yet may offer benefits from lower dispersion of phase shift as well as a more in-depth insight into the dynamic nature of cerebral autoregulation.
Efficient detection of a CW signal with a linear frequency drift
NASA Technical Reports Server (NTRS)
Swarztrauber, Paul N.; Bailey, David H.
1989-01-01
An efficient method is presented for the detection of a continuous wave (CW) signal with a frequency drift that is linear in time. Signals of this type occur in transmissions between any two locations that are accelerating relative to one another, e.g., transmissions from the Voyager spacecraft. We assume that both the frequency and the drift are unknown. We also assume that the signal is weak compared to the Gaussian noise. The signal is partitioned into subsequences whose discrete Fourier transforms provide a sequence of instantaneous spectra at equal time intervals. These spectra are then accumulated with a shift that is proportional to time. When the shift is equal to the frequency drift, the signal to noise ratio increases and detection occurs. Here, we show how to compute these accumulations for many shifts in an efficient manner using a variety of Fast Fourier Transformations (FFT). Computing time is proportional to L log L where L is the length of the time series.
Uniaxial stress induced symmetry breaking for muon sites in Fe
NASA Technical Reports Server (NTRS)
Kossler, W. J.; Namkung, M.; Hitti, B.; Li, Y.; Kempton, J.; Stronach, C. E.; Goode, L. R., Jr.; Lankford, W. F.; Patterson, B. D.; Kuendig, W.
1984-01-01
Uniaxial stress was used on Fe single crystals to induce muon precession frequency shifts. The frequency shift for a nominally pure Fe sample at 302K was -0.34 + or - .023 MHz per 100 microstrain along the 100 magnetization axis. This corresponds to a change of magnetic field at the muon of 25.1 + to 1.6G/100 magnetic moment. For an Fe (3wt%Si) single crystal the shifts were -0.348 + or - .008 MHz/100 magnetic moment. The agreement between the shifts for Fe and Fe(3wt%Si) shows the effect to be intrinsic to iron and not strongly impurity sensitive. These shifts and their temperature dependence (1/T) are dominated by the effect of strain inducted population shifts between crystallographically equivalent, but mgnetically inequivalent sites. Their magnitudes are in good agreement ith previous theoretical predictions and by previous extrapolation from calculations on Nb and V especially if both 4T(0) and 1T sites contribute comparably.
Investigating lipids as a source of chemical exchange-induced MRI frequency shifts.
Shmueli, K; Dodd, S J; van Gelderen, P; Duyn, J H
2017-04-01
While magnetic susceptibility is a major contributor to NMR resonance frequency variations in the human brain, a substantial contribution may come from the chemical exchange of protons between water and other molecules. Exchange-induced frequency shifts f e have been measured in tissue and protein solutions, but relatively lipid-rich white matter (WM) has a larger f e than gray matter, suggesting that lipids could contribute. Galactocerebrosides (GC) are a prime candidate as they are abundant in WM and susceptible to exchange. To investigate this, f e was measured in a model of WM lipid membranes in the form of multilamellar vesicles (MLVs), consisting of a 1:2 molar ratio of GC and phospholipids (POPC), and in MLVs with POPC only. Chemical shift imaging with 15% volume fraction of dioxane, an internal reference whose protons are assumed not to undergo chemical exchange, was used to remove susceptibility-induced frequency shifts in an attempt to measure f e in MLVs at several lipid concentrations. Initial analysis of these measurements indicated a necessity to correct for small unexpected variations in dioxane concentration due to its effect on the water frequency shift. To achieve this, the actual dioxane concentration was inferred from spectral analysis and its additional contribution to f e was removed through separate experiments which showed that the water-dioxane frequency shift depended linearly on the dioxane concentration at low concentrations with a proportionality constant of -0.021 ± 0.002 ppb/mM in agreement with published experiments. Contrary to expectations and uncorrected results, for GC + POPC vesicles, the dependence of the corrected f e on GC concentration was insignificant (0.023 ± 0.037 ppb/mM; r 2 = 0.085, p > 0.57), whereas for the POPC-only vesicles a small but significant linear increase with POPC concentration was found: 0.044 ± 0.008 ppb/mM (r 2 = 0.877, p < 0.01). These findings suggest that the exchange-induced contribution of lipids to frequency contrast in WM may be small. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Frequency up-conversion of a high-power microwave pulse propagating in a self-generated plasma
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Ren, A.
1992-01-01
In the study of the propagation of a high-power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. A frequency autoconversion process that can lead to reflectionless propagation of powerful electromagnetic pulses in self-generated plasmas is studied. The theory shows that, under the proper condition, the carrier frequency omega of the pulse shifts upward during the growth of local plasma frequency omega(pe). Thus, the self-generated plasma remains underdense to the pulse. A chamber experiment to demonstrate the frequency autoconversion during the pulse propagation through the self-generated plasma is conducted. The detected frequency shift is compared with the theoretical result calculated by using the measured electron density distribution along the propagation path of the pulse. Good agreement is obtained.
RF-MEMS Load Sensors with Enhanced Q-factor and Sensitivity in a Suspended Architecture.
Melik, Rohat; Unal, Emre; Perkgoz, Nihan Kosku; Puttlitz, Christian; Demir, Hilmi Volkan
2011-03-01
In this paper, we present and demonstrate RF-MEMS load sensors designed and fabricated in a suspended architecture that increases their quality-factor (Q-factor), accompanied with an increased resonance frequency shift under load. The suspended architecture is obtained by removing silicon under the sensor. We compare two sensors that consist of 195 μm × 195 μm resonators, where all of the resonator features are of equal dimensions, but one's substrate is partially removed (suspended architecture) and the other's is not (planar architecture). The single suspended device has a resonance of 15.18 GHz with 102.06 Q-factor whereas the single planar device has the resonance at 15.01 GHz and an associated Q-factor of 93.81. For the single planar device, we measured a resonance frequency shift of 430 MHz with 3920 N of applied load, while we achieved a 780 MHz frequency shift in the single suspended device. In the planar triplet configuration (with three devices placed side by side on the same chip, with the two outmost ones serving as the receiver and the transmitter), we observed a 220 MHz frequency shift with 3920 N of applied load while we obtained a 340 MHz frequency shift in the suspended triplet device with 3920 N load applied. Thus, the single planar device exhibited a sensitivity level of 0.1097 MHz/N while the single suspended device led to an improved sensitivity of 0.1990 MHz/N. Similarly, with the planar triplet device having a sensitivity of 0.0561 MHz/N, the suspended triplet device yielded an enhanced sensitivity of 0.0867 MHz/N.
Treesuwan, Witcha; Hirao, Hajime; Morokuma, Keiji; Hannongbua, Supa
2012-05-01
As the mechanism underlying the sense of smell is unclear, different models have been used to rationalize structure-odor relationships. To gain insight into odorant molecules from bread baking, binding energies and vibration spectra in the gas phase and in the protein environment [7-transmembrane helices (7TMHs) of rhodopsin] were calculated using density functional theory [B3LYP/6-311++G(d,p)] and ONIOM [B3LYP/6-311++G(d,p):PM3] methods. It was found that acetaldehyde ("acid" category) binds strongly in the large cavity inside the receptor, whereas 2-ethyl-3-methylpyrazine ("roasted") binds weakly. Lys296, Tyr268, Thr118 and Ala117 were identified as key residues in the binding site. More emphasis was placed on how vibrational frequencies are shifted and intensities modified in the receptor protein environment. Principal component analysis (PCA) suggested that the frequency shifts of C-C stretching, CH(3) umbrella, C = O stretching and CH(3) stretching modes have a significant effect on odor quality. In fact, the frequency shifts of the C-C stretching and C = O stretching modes, as well as CH(3) umbrella and CH(3) symmetric stretching modes, exhibit different behaviors in the PCA loadings plot. A large frequency shift in the CH(3) symmetric stretching mode is associated with the sweet-roasted odor category and separates this from the acid odor category. A large frequency shift of the C-C stretching mode describes the roasted and oily-popcorn odor categories, and separates these from the buttery and acid odor categories.
High-resolution tide projections reveal extinction threshold in response to sea-level rise.
Field, Christopher R; Bayard, Trina S; Gjerdrum, Carina; Hill, Jason M; Meiman, Susan; Elphick, Chris S
2017-05-01
Sea-level rise will affect coastal species worldwide, but models that aim to predict these effects are typically based on simple measures of sea level that do not capture its inherent complexity, especially variation over timescales shorter than 1 year. Coastal species might be most affected, however, by floods that exceed a critical threshold. The frequency and duration of such floods may be more important to population dynamics than mean measures of sea level. In particular, the potential for changes in the frequency and duration of flooding events to result in nonlinear population responses or biological thresholds merits further research, but may require that models incorporate greater resolution in sea level than is typically used. We created population simulations for a threatened songbird, the saltmarsh sparrow (Ammodramus caudacutus), in a region where sea level is predictable with high accuracy and precision. We show that incorporating the timing of semidiurnal high tide events throughout the breeding season, including how this timing is affected by mean sea-level rise, predicts a reproductive threshold that is likely to cause a rapid demographic shift. This shift is likely to threaten the persistence of saltmarsh sparrows beyond 2060 and could cause extinction as soon as 2035. Neither extinction date nor the population trajectory was sensitive to the emissions scenarios underlying sea-level projections, as most of the population decline occurred before scenarios diverge. Our results suggest that the variation and complexity of climate-driven variables could be important for understanding the potential responses of coastal species to sea-level rise, especially for species that rely on coastal areas for reproduction. © 2016 John Wiley & Sons Ltd.
Trecarichi, Enrico M; Tumbarello, Mario
2014-04-01
In the recent years, several studies involving cancer patients have demonstrated a clear trend in the epidemiology of bacterial infections showing a shift in the prevalence from Gram-positive to Gram-negative bacteria and the extensive emergence of antimicrobial-resistant strains among Gram-negatives isolated from the blood. The aim of this systematic review was to examine the recent trends in epidemiology and antimicrobial resistance in Gram-negatives recovered from neutropenic cancer patients, with particular emphasis on the impact of antimicrobial resistance on the clinical outcome of severe infections caused by such microorganisms. Overall, from 2007 to date, the rate of Gram-negative bacteria recovery ranged from 24.7 to 75.8% (mean 51.3%) in cancer patient cohorts. Escherichia coli represented the most common species (mean frequency of isolation 32.1%) among the Gram-negatives, followed by Pseudomonas aeruginosa (mean frequency of isolation 20.1%). An increasing frequency of Acinetobacter spp. and Stenotrophomonas maltophilia was also reported. Increased rates of multidrug-resistant Gram-negative strains have been highlighted among Enterobacteriaceae and nonfermenting Gram-negative rods, despite discontinuation of fluoroquinolone-based antibacterial prophylaxis for neutropenic patients. In addition, antimicrobial resistance and/or the inadequacy of empirical antibiotic treatment have been frequently linked to a worse outcome in cancer patients with bloodstream infections caused by Gram-negative isolates. Sound knowledge of the local distribution of pathogens and their susceptibility patterns and prompt initiation of effective antimicrobial treatment for severe infections caused by Gram-negative bacteria are essential in cancer patients.
Method for ambiguity resolution in range-Doppler measurements
NASA Technical Reports Server (NTRS)
Heymsfield, Gerald M. (Inventor); Miller, Lee S. (Inventor)
1994-01-01
A method for resolving range and Doppler target ambiguities when the target has substantial range or has a high relative velocity in which a first signal is generated and a second signal is also generated which is coherent with the first signal but at a slightly different frequency such that there exists a difference in frequency between these two signals of Delta f(sub t). The first and second signals are converted into a dual-frequency pulsed signal, amplified, and the dual-frequency pulsed signal is transmitted towards a target. A reflected dual-frequency signal is received from the target, amplified, and changed to an intermediate dual-frequency signal. The intermediate dual-frequency signal is amplified, with extracting of a shifted difference frequency Delta f(sub r) from the amplified intermediate dual-frequency signal done by a nonlinear detector. The final step is generating two quadrature signals from the difference frequency Delta f(sub t) and the shifted difference frequency Delta f(sub r) and processing the two quadrature signals to determine range and Doppler information of the target.
Research and development for a ground-based hydrogen-maser system
NASA Technical Reports Server (NTRS)
1972-01-01
The results of a joint experiment aimed primarily at the determination of the frequency of the H(1) hyperfine transition are reported. The transition frequency value for Cs-133 hyperfine transition is found. The result is the mean of two independent evaluations against the cesium reference, which differ by 0.002 Hz. The one-sigma uncertainty of the value nu sub H is also estimated to be 0.002 Hz. One evaluation is based on wall shift experiments at Harvard University; the other is a result of new wall shift measurement using many storage bulbs of different sizes at the National Bureau of Standards. The experimental procedures and the applied corrections are described. Results for the wall shift and for the frequency of hydrogen are compared with previously published values, and error limits of the experiments are discussed.
Ballestra, Alberto; Somà, Aurelio; Pavanello, Renato
2008-02-06
The dynamic characterization of a set of gold micro beams by electrostatic excitation in presence of residual stress gradient has been studied experimentally. A method to determine the micro-cantilever residual stress gradient by measuring the deflection and curvature and then identifying the residual stress model by means of frequency shift behaviour is presented. A comparison with different numerical FEM models and experimental results has been carried out, introducing in the model the residual stress of the structures, responsible for an initial upward curvature. Dynamic spectrum data are measured via optical interferometry and experimental frequency shift curves are obtained by increasing the dc voltage applied to the specimens. A good correspondence is pointed out between measures and numerical models so that the residual stress effect can be evaluated for different configurations.
Ballestra, Alberto; Somà, Aurelio; Pavanello, Renato
2008-01-01
The dynamic characterization of a set of gold micro beams by electrostatic excitation in presence of residual stress gradient has been studied experimentally. A method to determine the micro-cantilever residual stress gradient by measuring the deflection and curvature and then identifying the residual stress model by means of frequency shift behaviour is presented. A comparison with different numerical FEM models and experimental results has been carried out, introducing in the model the residual stress of the structures, responsible for an initial upward curvature. Dynamic spectrum data are measured via optical interferometry and experimental frequency shift curves are obtained by increasing the dc voltage applied to the specimens. A good correspondence is pointed out between measures and numerical models so that the residual stress effect can be evaluated for different configurations. PMID:27879733
Experimental investigation on frequency shifting of imperfect adhesively bonded pipe joints
NASA Astrophysics Data System (ADS)
Haiyam, F. N.; Hilmy, I.; Sulaeman, E.; Firdaus, T.; Adesta, E. Y. T.
2018-01-01
Inspection tests for any manufactured structure are compulsory in order to detect the existence of damage.It is to ensure the product integrity, reliability and to avoid further catastrophic failure. In this research, modal analysis was utilized to detect structural damage as one of the Non Destructive Testing (NDT) methods. Comparing the vibration signal of a healthy structure with a non-healthy signal was performed. A modal analysis of an adhesively bonded pipe joint was investigated with a healthy joint as a reference. The damage joint was engineered by inserting a nylon fiber, which act as an impurity at adhesive region. The impact test using hammer was utilized in this research. Identification of shifting frequency of a free supported and clamped pipe joint was performed.It was found that shifting frequency occurred to the lower side by 5%.
Varied absorption peaks of dual-band metamaterial absorber analysis by using reflection theory
NASA Astrophysics Data System (ADS)
Xiong, Han; Yu, Yan-Tao; Tang, Ming-Chun; Chen, Shi-Yong; Liu, Dan-Ping; Ou, Xiang; Zeng, Hao
2016-03-01
Cross-resonator metamaterial absorbers (MMA) have been widely investigated from microwave to optical frequencies. However, only part of the factors influencing the absorption properties were analyzed in previous works at the same time. In order to completely understand how the spacer thickness, dielectric parameter and incidence angle affect the absorption properties of the dual-band MMA, two sets of simulation were performed. It was found that with increasing incident angles, the low-frequency absorption peak showed a blue shift, while the high-frequency absorption peaks showed a red shift. However, with the increase in spacer thickness, both of the absorption peaks showed a red shift. By using the reflection theory expressions, the physical mechanism of the cross-resonator MMA was well explained. This method provides an effective way to analyze multi-band absorber in technology.
High-speed optical coherence tomography using fiberoptic acousto-optic phase modulation
NASA Astrophysics Data System (ADS)
Xie, Tuqiang; Wang, Zhenguo; Pan, Yingtian
2003-12-01
We report a new rapid-scanning optical delay device suitable for high-speed optical coherence tomography (OCT) in which an acousto-optic modulator (AOM) is used to independently modulate the Doppler frequency shift of the reference light beam for optical heterodyne detection. Experimental results show that the fluctuation of the measured Doppler frequency shift is less than +/-0.2% over 95% duty cycle of OCT imaging, thus allowing for enhanced signal-to-noise ratio of optical heterodyne detection. The increased Doppler frequency shift by AOM also permits complete envelop demodulation without the compromise of reducing axial resolution; if used with a resonant rapid-scanning optical delay, it will permit high-performance real-time OCT imaging. Potentially, this new rapid-scanning optical delay device will improve the performance of high-speed Doppler OCT techniques.
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10{sup -17} Level
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westergaard, P. G.; Lodewyck, J.; Lecallier, A.
2011-05-27
We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5x10{sup -17} after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice relatedmore » perturbations will not affect the clock accuracy down to the 10{sup -17} level, even for lattices as deep as 150 recoil energies.« less
What is the Temporal Analog of Reflection and Refraction of Optical Beams?
Plansinis, B W; Donaldson, W R; Agrawal, G P
2015-10-30
It is shown numerically and analytically that when an optical pulse approaches a moving temporal boundary across which the refractive index changes, it undergoes a temporal equivalent of reflection and refraction of optical beams at a spatial boundary. The main difference is that the role of angles is played by changes in the frequency. The frequency dependence of the dispersion of the material in which the pulse is propagating plays a fundamental role in determining the frequency shifts experienced by the reflected and refracted pulses. Our analytic expressions for these frequency shifts allow us to find the condition under which an analog of total internal reflection may occur at the temporal boundary.
Harnsberger, James D.; Svirsky, Mario A.; Kaiser, Adam R.; Pisoni, David B.; Wright, Richard; Meyer, Ted A.
2012-01-01
Cochlear implant (CI) users differ in their ability to perceive and recognize speech sounds. Two possible reasons for such individual differences may lie in their ability to discriminate formant frequencies or to adapt to the spectrally shifted information presented by cochlear implants, a basalward shift related to the implant’s depth of insertion in the cochlea. In the present study, we examined these two alternatives using a method-of-adjustment (MOA) procedure with 330 synthetic vowel stimuli varying in F1 and F2 that were arranged in a two-dimensional grid. Subjects were asked to label the synthetic stimuli that matched ten monophthongal vowels in visually presented words. Subjects then provided goodness ratings for the stimuli they had chosen. The subjects’ responses to all ten vowels were used to construct individual perceptual “vowel spaces.” If CI users fail to adapt completely to the basalward spectral shift, then the formant frequencies of their vowel categories should be shifted lower in both F1 and F2. However, with one exception, no systematic shifts were observed in the vowel spaces of CI users. Instead, the vowel spaces differed from one another in the relative size of their vowel categories. The results suggest that differences in formant frequency discrimination may account for the individual differences in vowel perception observed in cochlear implant users. PMID:11386565
EUV phase-shifting masks and aberration monitors
NASA Astrophysics Data System (ADS)
Deng, Yunfei; Neureuther, Andrew R.
2002-07-01
Rigorous electromagnetic simulation with TEMPEST is used to examine the use of phase-shifting masks in EUV lithography. The effects of oblique incident illumination and mask patterning by ion-mixing of multilayers are analyzed. Oblique incident illumination causes streamers at absorber edges and causes position shifting in aerial images. The diffraction waves between ion-mixed and pristine multilayers are observed. The phase-shifting caused by stepped substrates is simulated and images show that it succeeds in creation of phase-shifting effects. The diffraction process at the phase boundary is also analyzed. As an example of EUV phase-shifting masks, a coma pattern and probe based aberration monitor is simulated and aerial images are formed under different levels of coma aberration. The probe signal rises quickly as coma increases as designed.
Economic design of control charts considering process shift distributions
NASA Astrophysics Data System (ADS)
Vommi, Vijayababu; Kasarapu, Rukmini V.
2014-09-01
Process shift is an important input parameter in the economic design of control charts. Earlier control chart designs considered constant shifts to occur in the mean of the process for a given assignable cause. This assumption has been criticized by many researchers since it may not be realistic to produce a constant shift whenever an assignable cause occurs. To overcome this difficulty, in the present work, a distribution for the shift parameter has been considered instead of a single value for a given assignable cause. Duncan's economic design model for chart has been extended to incorporate the distribution for the process shift parameter. It is proposed to minimize total expected loss-cost to obtain the control chart parameters. Further, three types of process shifts namely, positively skewed, uniform and negatively skewed distributions are considered and the situations where it is appropriate to use the suggested methodology are recommended.
The effects of a hot outer atmosphere on acoustic-gravity waves
NASA Technical Reports Server (NTRS)
Hindman, Bradley W.; Zweibel, Ellen G.
1994-01-01
We examine the effects of a hot chromosphere and corona on acoustic-gravity waves in the Sun. We use a simple solar model consisting of a neutrally stable polytrope smoothly matched to an isothermal chromosphere or corona. The temperature of the isothermal region is higher than the minimum temperature of the model. We ignore sphericity, magnetic fields, changes in the gravitational potential, and nonadiabatic effects. We find a family of atmospheric g-modes whose cavity is formed by the extremum in the buoyancy frequency at the transition region. The f-mode is the zero-order member of this family. For large values of the harmonic degree l, f-mode frequencies are below the classic f-mode frequency, mu=(gk)(exp 1/2), whereas at small values of l, the f-mode is identical to the classical f-mode solution. We also find a family of g-modes residing in the low chromosphere. Frequency shifts of p-modes can be positive or negative. When the frequency is less than the acoustic cutoff frequency of the upper isothermal atmsophere, the frequency of the upper isothermal atmosphere, the frequency shift is negative, but when the frequency is above this cutoff, the shifts can be positive. High-frequency acoustic waves which are not reflected by the photospheric cutoff are reflected at the corona by the high sound speed for moderate values of l and v. This result is independent of the solar model as long as the corona is very hot. The data are inconsistent with this result, and reasons for this discrepancy are discussed.
Ionizing Radiation and the Ear
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borsanyi, Steven J.
The effects of ionizing radiation on the ears of 100 patients were studied in the course of treatment of malignant head and neck tumors by teleradiation using Co 60. Early changes consisted of radiation otitis media and a transient vasculitis of the vessels of the inner ear, resulting in hearing loss, tinnitus, and temporary recruitment. While no permanent changes were detected microscopically shortly after the completion of radiation in the cochlea or labyrinth, late changes sometimes occurred in the temporal bone as a result of an obliterating endarteritis. The late changes were separate entities caused primarily by obliterating endarteritis andmore » alterations in the collagen. Radiation affected the hearing of individuals selectively. When hearing threshold shift did occur, the shift was not great. The 4000 cps frequency showed a greater deficit in hearing capacity during the tests, while the area least affected appeared to be in the region of 2000 cps. The shift in speech reception was not significant and it was correlated with the over-all change in response to pure tones. Discrimination did not appear to be affected. Proper shielding of the ear with lead during radiation, when possible, eliminated most complications. (H.R.D.)« less
Power allocation and range performance considerations for a dual-frequency EBPSK/MPPSK system
NASA Astrophysics Data System (ADS)
Yao, Yu; Wu, Lenan; Zhao, Junhui
2017-12-01
Extended binary phase shift keying/M-ary position phase shift keying (EBPSK/MPPSK)-MODEM provides radar and communication functions on a single hardware platform with a single waveform. However, its range estimation accuracy is worse than continuous-wave (CW) radar because of the imbalance of power in two carrier frequencies. In this article, the power allocation method for dual-frequency EBPSK/MPPSK modulated systems is presented. The power of two signal transmitters is adequately allocated to ensure that the power in two carrier frequencies is equal. The power allocation ratios for two types of modulation systems are obtained. Moreover, considerations regarding the range of operation of the dual-frequency system are analysed. In addition to theoretical considerations, computer simulations are provided to illustrate the performance.
Ishihara, Daisuke; Horie, T; Denda, Mitsunori
2009-01-01
In this study, the passive pitching due to wing torsional flexibility and its lift generation in dipteran flight were investigated using (a) the non-linear finite element method for the fluid-structure interaction, which analyzes the precise motions of the passive pitching of the wing interacting with the surrounding fluid flow, (b) the fluid-structure interaction similarity law, which characterizes insect flight, (c) the lumped torsional flexibility model as a simplified dipteran wing, and (d) the analytical wing model, which explains the characteristics of the passive pitching motion in the simulation. Given sinusoidal flapping with a frequency below the natural frequency of the wing torsion, the resulting passive pitching in the steady state, under fluid damping, is approximately sinusoidal with the advanced phase shift. We demonstrate that the generated lift can support the weight of some Diptera.
NASA Astrophysics Data System (ADS)
Klingel, S.; Oesterschulze, E.
2017-08-01
The apparent contact angle is frequently used as an indicator of the wetting state of a surface in contact with a liquid. However, the apparent contact angle is subject to hysteresis that depends furthermore strongly on both the material properties and the roughness and structure of the sample surface. In this work, we show that integrated microresonators can be exploited to determine the wetting state by measuring both the frequency shift caused by the hydrodynamic mass of the liquid and the change in the quality factor as a result of damping. For this, we integrated electrically driven hybrid bridge resonators (HBRs) into a periodically structured surface intended for wetting experiments. We could clearly differentiate between the Wenzel state and the Cassie-Baxter state because the resonant frequency and quality factor of the HBR changed by over 35% and 40%, respectively. This offers the capability to unambiguously distinguish between the different wetting states.
NASA Technical Reports Server (NTRS)
1973-01-01
An analysis of Very Low Frequency propagation in the atmosphere in the 10-14 kHz range leads to a discussion of some of the more significant causes of phase perturbation. The method of generating sky-wave corrections to predict the Omega phase is discussed. Composite Omega is considered as a means of lane identification and of reducing Omega navigation error. A simple technique for generating trapezoidal model (T-model) phase prediction is presented and compared with the Navy predictions and actual phase measurements. The T-model prediction analysis illustrates the ability to account for the major phase shift created by the diurnal effects on the lower ionosphere. An analysis of the Navy sky-wave correction table is used to provide information about spatial and temporal correlation of phase correction relative to the differential mode of operation.
Perturbation measurement of waveguides for acoustic thermometry
NASA Astrophysics Data System (ADS)
Lin, H.; Feng, X. J.; Zhang, J. T.
2013-09-01
Acoustic thermometers normally embed small acoustic transducers in the wall bounding a gas-filled cavity resonator. At high temperature, insulators of transducers loss electrical insulation and degrade the signal-to-noise ratio. One essential solution to this technical trouble is to couple sound by acoustic waveguides between resonator and transducers. But waveguide will break the ideal acoustic surface and bring perturbations(Δf+ig) to the ideal resonance frequency. The perturbation model for waveguides was developed based on the first-order acoustic theory in this paper. The frequency shift Δf and half-width change g caused by the position, length and radius of waveguides were analyzed using this model. Six different length of waveguides (52˜1763 mm) were settled on the cylinder resonator and the perturbation (Δf+ig) were measured at T=332 K and p=250˜500 kPa. The experiment results agreed with the theoretical prediction very well.
Measurement of thin films using very long acoustic wavelengths
NASA Astrophysics Data System (ADS)
Clement, G. T.; Nomura, H.; Adachi, H.; Kamakura, T.
2013-12-01
A procedure for measuring material thickness by means of necessarily long acoustic wavelengths is examined. The approach utilizes a temporal phase lag caused by the impulse time of wave momentum transferred through a thin layer that is much denser than its surrounding medium. In air, it is predicted that solid or liquid layers below approximately 1/2000 of the acoustic wavelength will exhibit a phase shift with an arctangent functional dependence on thickness and layer density. The effect is verified for thin films on the scale of 10 μm using audible frequency sound (7 kHz). Soap films as thin as 100 nm are then measured using 40 kHz air ultrasound. The method's potential for imaging applications is demonstrated by combining the approach with near-field holography, resulting in reconstructions with sub-wavelength resolution in both the depth and lateral directions. Potential implications at very high and very low acoustic frequencies are discussed.
NASA Astrophysics Data System (ADS)
Hubenthal, Frank; Ziegler, Torsten; Hendrich, Christian; Träger, Frank
2004-03-01
For many applications like surface enhanced Raman scattering in which the optical field enhancement associated with surface plasmon excitation is exploited, tunability of this collective resonance over a wide range is required. For this purpose we have prepared Ag/Au core shell and Ag/Au alloyed nanoparticles with different shell thicknesses and different percentages of the two metals. The nanoparticles were made by subsequent deposition of Ag and Au atoms on dielectric substrates followed by diffusion and nucleation or heat treatment. Depending on the Au shell thickness the plasmon frequency can be tuned, e.g. from 2.8 eV (442 nm) to 2.1 eV (590 nm). Annealing of the core-shell nanoparticles causes a shift of the resonance frequency to 2.6 eV. Theoretical modelling allows us to attribute this observation to the production of alloyed nanoparticles. Possible application of the Ag/Au nanoparticles will be discussed.
NASA Astrophysics Data System (ADS)
Liu, Nan; Steele, Andrew; Nittler, Larry R.; Stroud, Rhonda M.; De Gregorio, Bradley T.; Alexander, Conel M. O'D.; Wang, Jianhua
2017-12-01
We report the development of a novel method to nondestructively identify presolar silicon carbide (SiC) grains with high initial 26Al/27Al ratios (>0.01) and extreme 13C-enrichments (12C/13C ≤ 10) by backscattered electron-energy dispersive X-ray (EDX) and micro-Raman analyses. Our survey of a large number of presolar SiC demonstrates that (1) 80% of core-collapse supernova and putative nova SiC can be identified by quantitative EDX and Raman analyses with >70% confidence; (2) 90% of presolar SiC are predominantly 3C-SiC, as indicated by their Raman transverse optical (TO) peak position and width; (3) presolar 3C-SiC with 12C/13C ≤ 10 show lower Raman TO phonon frequencies compared to mainstream 3C-SiC. The downward shifted phonon frequencies of the 13C-enriched SiC with concomitant peak broadening are a natural consequence of isotope substitution. 13C-enriched SiC can therefore be identified by micro-Raman analysis; (4) larger shifts in the Raman TO peak position and width indicate deviations from the ideal 3C structure, including rare polytypes. Coordinated transmission electron microscopy analysis of one X and one mainstream SiC grain found them to be of 6H and 15R polytypes, respectively; (5) our correlated Raman and NanoSIMS study of mainstream SiC shows that high nitrogen content is a dominant factor in causing mainstream SiC Raman peak broadening without significant peak shifts; and (6) we found that the SiC condensation conditions in different stellar sites are astonishingly similar, except for X grains, which often condensed more rapidly and at higher atmospheric densities and temperatures, resulting in a higher fraction of grains with much downward shifted and broadened Raman TO peaks.
NASA Astrophysics Data System (ADS)
Zhu, Zihang; Zhao, Shanghong; Yao, Zhoushi; Tan, Qinggui; Li, Yongjun; Chu, Xingchun; Shi, Lei; Zhang, Xi
2012-06-01
We propose a novel approach to generate quadrupling-frequency optical millimeter-wave using a dual-drive Mach-Zehnder modulator (MZM) in radio-over-fiber system. By properly adjusting the phase difference in the two modulation arms of MZM, the direct current (DC) bias, the modulation index and the gain of base-band signal, the quadrupling-frequency optical millimeter-wave with signal only carried by one second-order sideband is generated. As the signal is transmitted along the fiber, there is no time shift of the codes caused by chromatic dispersion. Theoretical analysis and simulation results show that the eye diagram keeps open and clear even when the quadrupling-frequency optical millimeter-wave are transmitted over 110 km and the power penalty is about 0.45 dB after fiber transmission distance of 60 km. Furthermore, due to another second-order sideband carrying no signals, a full duplex radio-over-fiber link based on wavelength reuse is also built to simplify the base station. The bidirectional 2.5 Gbit/s data is successfully transmitted over 40 km standard single mode fiber with less than 0.6 dB power penalty in the simulation.
Modeling perspectives on echolocation strategies inspired by bats flying in groups.
Lin, Yuan; Abaid, Nicole
2015-12-21
Bats navigating with echolocation - which is a type of active sensing achieved by interpreting echoes resulting from self-generated ultrasonic pulses - exhibit unique behaviors during group flight. While bats may benefit from eavesdropping on their peers׳ echolocation, they also potentially suffer from confusion between their own and peers׳ pulses, caused by an effect called frequency jamming. This hardship of group flight is supported by experimental observations of bats simplifying their sound-scape by shifting their pulse frequencies or suppressing echolocation altogether. Here, we investigate eavesdropping and varying pulse emission rate from a modeling perspective to understand these behaviors׳ potential benefits and detriments. We define an agent-based model of echolocating bats avoiding collisions in a three-dimensional tunnel. Through simulation, we show that bats with reasonably accurate eavesdropping can reduce collisions compared to those neglecting information from peers. In large populations, bats minimize frequency jamming by decreasing pulse emission rate, while collision risk increases; conversely, increasing pulse emission rate minimizes collisions by allowing more sensing information generated per bat. These strategies offer benefits for both biological and engineered systems, since frequency jamming is a concern in systems using active sensing. Copyright © 2015 Elsevier Ltd. All rights reserved.
Xu, Renfeng; Bradley, Arthur; Thibos, Larry N.
2013-01-01
Purpose We tested the hypothesis that pupil apodization is the basis for central pupil bias of spherical refractions in eyes with spherical aberration. Methods We employed Fourier computational optics in which we vary spherical aberration levels, pupil size, and pupil apodization (Stiles Crawford Effect) within the pupil function, from which point spread functions and optical transfer functions were computed. Through-focus analysis determined the refractive correction that optimized retinal image quality. Results For a large pupil (7 mm), as spherical aberration levels increase, refractions that optimize the visual Strehl ratio mirror refractions that maximize high spatial frequency modulation in the image and both focus a near paraxial region of the pupil. These refractions are not affected by Stiles Crawford Effect apodization. Refractions that optimize low spatial frequency modulation come close to minimizing wavefront RMS, and vary with level of spherical aberration and Stiles Crawford Effect. In the presence of significant levels of spherical aberration (e.g. C40 = 0.4 µm, 7mm pupil), low spatial frequency refractions can induce −0.7D myopic shift compared to high SF refraction, and refractions that maximize image contrast of a 3 cycle per degree square-wave grating can cause −0.75D myopic drift relative to refractions that maximize image sharpness. Discussion Because of small depth of focus associated with high spatial frequency stimuli, the large change in dioptric power across the pupil caused by spherical aberration limits the effective aperture contributing to the image of high spatial frequencies. Thus, when imaging high spatial frequencies, spherical aberration effectively induces an annular aperture defining that portion of the pupil contributing to a well-focused image. As spherical focus is manipulated during the refraction procedure, the dimensions of the annular aperture change. Image quality is maximized when the inner radius of the induced annulus falls to zero, thus defining a circular near paraxial region of the pupil that determines refraction outcome. PMID:23683093
Soesbe, Todd C; Wu, Yunkou; Dean Sherry, A
2013-07-01
Paramagnetic chemical exchange saturation transfer (PARACEST) complexes are exogenous contrast agents that have great potential to further extend the functional and molecular imaging capabilities of magnetic resonance. As a result of the presence of a central paramagnetic lanthanide ion (Ln(3+) ≠ La(3+) , Gd(3+) , Lu(3+) ) within the chelate, the resonance frequencies of exchangeable protons bound to the PARACEST agent are shifted far away from the bulk water frequency. This large chemical shift, combined with an extreme sensitivity to the chemical exchange rate, make PARACEST agents ideally suited for the reporting of significant biological metrics, such as temperature, pH and the presence of metabolites. In addition, the ability to turn PARACEST agents 'off' and 'on' using a frequency-selective saturation pulse gives them a distinct advantage over Gd(3+) -based contrast agents. A current challenge for PARACEST research is the translation of the promising in vitro results into in vivo systems. This short review article first describes the basic theory behind PARACEST contrast agents, their benefits over other contrast agents and their applications to MRI. It then describes some of the recent PARACEST research results: specifically, pH measurements using water molecule exchange rate modulation, T2 exchange contrast caused by water molecule exchange, the use of ultrashort TEs (TE < 10 µs) to overcome T2 exchange line broadening and the potential application of T2 exchange as a new contrast mechanism for MRI. Copyright © 2012 John Wiley & Sons, Ltd.
Residual Inhibition Functions Overlap Tinnitus Spectra and the Region of Auditory Threshold Shift
Moffat, Graeme; Baumann, Michael; Ward, Lawrence M.
2008-01-01
Animals exposed to noise trauma show augmented synchronous neural activity in tonotopically reorganized primary auditory cortex consequent on hearing loss. Diminished intracortical inhibition in the reorganized region appears to enable synchronous network activity that develops when deafferented neurons begin to respond to input via their lateral connections. In humans with tinnitus accompanied by hearing loss, this process may generate a phantom sound that is perceived in accordance with the location of the affected neurons in the cortical place map. The neural synchrony hypothesis predicts that tinnitus spectra, and heretofore unmeasured “residual inhibition functions” that relate residual tinnitus suppression to the center frequency of masking sounds, should cover the region of hearing loss in the audiogram. We confirmed these predictions in two independent cohorts totaling 90 tinnitus subjects, using computer-based tools designed to assess the psychoacoustic properties of tinnitus. Tinnitus spectra and residual inhibition functions for depth and duration increased with the amount of threshold shift over the region of hearing impairment. Residual inhibition depth was shallower when the masking sounds that were used to induce residual inhibition showed decreased correspondence with the frequency spectrum and bandwidth of the tinnitus. These findings suggest that tinnitus and its suppression in residual inhibition depend on processes that span the region of hearing impairment and not on mechanisms that enhance cortical representations for sound frequencies at the audiometric edge. Hearing thresholds measured in age-matched control subjects without tinnitus implicated hearing loss as a factor in tinnitus, although elevated thresholds alone were not sufficient to cause tinnitus. PMID:18712566
Zhou, Da-Peng; Li, Wenhai; Chen, Liang; Bao, Xiaoyi
2013-01-31
A distributed optical fiber sensor with the capability of simultaneously measuring temperature and strain is proposed using a large effective area non-zero dispersion shifted fiber (LEAF) with sub-meter spatial resolution. The Brillouin frequency shift is measured using Brillouin optical time-domain analysis (BOTDA) with differential pulse-width pair technique, while the spectrum shift of the Rayleigh backscatter is measured using optical frequency-domain reflectometry (OFDR). These shifts are the functions of both temperature and strain, and can be used as two independent parameters for the discrimination of temperature and strain. A 92 m measurable range with the spatial resolution of 50 cm is demonstrated experimentally, and accuracies of ±1.2 °C in temperature and ±15 με in strain could be achieved.
Ha, Jeong-Hyon; Lee, Kyung-Koo; Park, Kwang-Hee; Choi, Jun-Ho; Jeon, Seung-Joon; Cho, Minhaeng
2009-05-28
By means of integrated and dispersed IR photon echo measurement methods, the vibrational dynamics of C-N stretch modes in 4-cyanophenol and 4-cyanophenoxide in methanol is investigated. The vibrational frequency-frequency correlation function (FFCF) is retrieved from the integrated photon echo signals by assuming that the FFCF is described by two exponential functions with about 400 fs and a few picosecond components. The excited state lifetimes of the C-N stretch modes of neutral and anionic 4-cyanophenols are 1.45 and 0.91 ps, respectively, and the overtone anharmonic frequency shifts are 25 and 28 cm(-1). At short waiting times, a notable underdamped oscillation, which is attributed to a low-frequency intramolecular vibration coupled to the CN stretch, in the integrated and dispersed vibrational echo as well as transient grating signals was observed. The spectral bandwidths of IR absorption and dispersed vibrational echo spectra of the 4-cyanophenoxide are significantly larger than those of its neutral form, indicating that the strong interaction between phenoxide and methanol causes large frequency fluctuation and rapid population relaxation. The resonance effects in a paradisubstituted aromatic compound would be of interest in understanding the conjugation effects and their influences on chemical reactivity of various aromatic compounds in organic solvents.
Stachiv, Ivo; Sittner, Petr
2018-01-01
Nanocantilevers have become key components of nanomechanical sensors that exploit changes in their resonant frequencies or static deflection in response to the environment. It is necessary that they can operate at a given, but adjustable, resonant frequency and/or static deflection ranges. Here we propose a new class of nanocantilevers with a significantly tunable spectrum of the resonant frequencies and changeable static deflection utilizing the unique properties of a phase-transforming NiTi film sputtered on the usual nanotechnology cantilever materials. The reversible frequency tuning and the adjustable static deflection are obtained by intentionally changing the Young’s modulus and the interlayer stress of the NiTi film during its phase transformation, while the usual cantilever elastic materials guarantee a high frequency actuation (up to tens of MHz). By incorporating the NiTi phase transformation characteristic into the classical continuum mechanics theory we present theoretical models that account for the nanocantilever frequency shift and variation in static deflection caused by a phase transformation of NiTi film. Due to the practical importance in nanomechanical sensors, we carry out a complete theoretical analysis and evaluate the impact of NiTi film on the cantilever Young’s modulus, static deflection, and the resonant frequencies. Moreover, the importance of proposed NiTi nanocantilever is illustrated on the nanomechanical based mass sensors. Our findings will be of value in the development of advanced nanotechnology sensors with intentionally-changeable physical and mechanical properties. PMID:29462996
Interpretation of frequency modulation atomic force microscopy in terms of fractional calculus
NASA Astrophysics Data System (ADS)
Sader, John E.; Jarvis, Suzanne P.
2004-07-01
It is widely recognized that small amplitude frequency modulation atomic force microscopy probes the derivative of the interaction force between tip and sample. For large amplitudes, however, such a physical connection is currently lacking, although it has been observed that the frequency shift presents a quantity intermediate to the interaction force and energy for certain force laws. Here we prove that these observations are a universal property of large amplitude frequency modulation atomic force microscopy, by establishing that the frequency shift is proportional to the half-fractional integral of the force, regardless of the force law. This finding indicates that frequency modulation atomic force microscopy can be interpreted as a fractional differential operator, where the order of the derivative/integral is dictated by the oscillation amplitude. We also establish that the measured frequency shift varies systematically from a probe of the force gradient for small oscillation amplitudes, through to the measurement of a quantity intermediate to the force and energy (the half-fractional integral of the force) for large oscillation amplitudes. This has significant implications to measurement sensitivity, since integrating the force will smooth its behavior, while differentiating it will enhance variations. This highlights the importance in choice of oscillation amplitude when wishing to optimize the sensitivity of force spectroscopy measurements to short-range interactions and consequently imaging with the highest possible resolution.
Single-resonator double-negative metamaterial
Warne, Larry K.; Basilio, Lorena I.; Langston, William L.; Johnson, William A.; Ihlefeld, Jon; Ginn, III, James C.; Clem, Paul G.; Sinclair, Michael B.
2016-06-21
Resonances can be tuned in dielectric resonators in order to construct single-resonator, negative-index metamaterials. For example, high-contrast inclusions in the form of metallic dipoles can be used to shift the first electric resonance down (in frequency) to the first magnetic resonance, or alternatively, air splits can be used to shift the first magnetic resonance up (in frequency) near the first electric resonance. Degenerate dielectric designs become especially useful in infrared- or visible-frequency applications where the resonator sizes associated with the lack of high-permittivity materials can become of sufficient size to enable propagation of higher-order lattice modes in the resulting medium.
Quantum-enhanced spectroscopy with entangled multiphoton states
NASA Astrophysics Data System (ADS)
Dinani, Hossein T.; Gupta, Manish K.; Dowling, Jonathan P.; Berry, Dominic W.
2016-06-01
Traditionally, spectroscopy is performed by examining the position of absorption lines. However, at frequencies near the transition frequency, additional information can be obtained from the phase shift. In this work we consider the information about the transition frequency obtained from both the absorption and the phase shift, as quantified by the Fisher information in an interferometric measurement. We examine the use of multiple single-photon states, NOON states, and numerically optimized states that are entangled and have multiple photons. We find the optimized states that improve over the standard quantum limit set by independent single photons for some atom number densities.
Search for supersolidity in solid 4He using multiple-mode torsional oscillators
Eyal, Anna; Mi, Xiao; Talanov, Artem V.; Reppy, John D.
2016-01-01
In 2004, Kim and Chan (KC) reported a decrease in the period of torsional oscillators (TO) containing samples of solid 4He, as the temperature was lowered below 0.2 K [Kim E, Chan MHW (2004) Science 305(5692):1941–1944]. These unexpected results constituted the first experimental evidence that the long-predicted supersolid state of solid 4He may exist in nature. The KC results were quickly confirmed in a number of other laboratories and created great excitement in the low-temperature condensed-matter community. Since that time, however, it has become clear that the period shifts seen in the early experiments can in large part be explained by an increase in the shear modulus of the 4He solid identified by Day and Beamish [Day J, Beamish J (2007) Nature 450(7171):853–856]. Using multiple-frequency torsional oscillators, we can separate frequency-dependent period shifts arising from changes in the elastic properties of the solid 4He from possible supersolid signals, which are expected to be independent of frequency. We find in our measurements that as the temperature is lowered below 0.2 K, a clear frequency-dependent contribution to the period shift arising from changes in the 4He elastic properties is always present. For all of the cells reported in this paper, however, there is always an additional small frequency-independent contribution to the total period shift, such as would be expected in the case of a transition to a supersolid state. PMID:27222579
Duffing revisited: phase-shift control and internal resonance in self-sustained oscillators
NASA Astrophysics Data System (ADS)
Arroyo, Sebastián I.; Zanette, Damián H.
2016-01-01
We address two aspects of the dynamics of the forced Duffing oscillator which are relevant to the technology of micromechanical devices and, at the same time, have intrinsic significance to the field of nonlinear oscillating systems. First, we study the stability of periodic motion when the phase shift between the external force and the oscillation is controlled - contrary to the standard case, where the control parameter is the frequency of the force. Phase-shift control is the operational configuration under which self-sustained oscillators - and, in particular, micromechanical oscillators - provide a frequency reference useful for time keeping. We show that, contrary to the standard forced Duffing oscillator, under phase-shift control oscillations are stable over the whole resonance curve, and provide analytical approximate expressions for the time dependence of the oscillation amplitude and frequency during transients. Second, we analyze a model for the internal resonance between the main Duffing oscillation mode and a higher-harmonic mode of a vibrating solid bar clamped at its two ends. We focus on the stabilization of the oscillation frequency when the resonance takes place, and present preliminary experimental results that illustrate the phenomenon. This synchronization process has been proposed to counteract the undesirable frequency-amplitude interdependence in nonlinear time-keeping micromechanical devices. Supplementary material in the form of one pdf file and one gif file available from the Journal web page at http://dx.doi.org/10.1140/epjb/e2015-60517-3
Suppression of thermal transients in advanced LIGO interferometers using CO2 laser preheating
NASA Astrophysics Data System (ADS)
Jaberian Hamedan, V.; Zhao, C.; Ju, L.; Blair, C.; Blair, D. G.
2018-06-01
In high optical power interferometric gravitational wave detectors, such as Advanced LIGO, the thermal effects due to optical absorption in the mirror coatings and the slow thermal response of fused silica substrate cause time dependent changes in the mirror profile. After locking, high optical power builds up in the arm cavities. Absorption induced heating causes optical cavity transverse mode frequencies to drift over a period of hours, relative to the fundamental mode. At high optical power this can cause time dependent transient parametric instability, which can lead to interferometer disfunction. In this paper, we model the use of CO2 laser heating designed to enable the interferometer to be maintained in a thermal condition such that transient changes in the mirrors are greatly reduced. This can minimize transient parametric instability and compensate dark port power fluctuations. Modeling results are presented for both single compensation where a CO2 laser acting on one test mass per cavity, and double compensation using one CO2 laser for each test mass. Using parameters of the LIGO Hanford Observatory X-arm as an example, single compensation allows the maximum mode frequency shift to be limited to 6% of its uncompensated value. However, single compensation causes transient degradation of the contrast defect. Double compensation minimise contrast defect degradation and reduces transients to less than 1% if the CO2 laser spot is positioned within 2 mm of the cavity beam position.
Laser frequency stabilization by light shift of optical-magnetic double resonances
NASA Astrophysics Data System (ADS)
Zhan, Yuanzhi; Peng, Xiang; Lin, Zaisheng; Gong, Wei; Guo, Hong
2015-05-01
This work adopts the light shift of optical-magnetic double resonance frequency in metastable-state 4He atoms to lock the laser center frequency to the magic point. At this magic frequency, both the left-circularly and right-circularly optical pumping processes will give the same value of optical-magnetic double resonance. With this method and after locking, experimental results show that the laser frequency fluctuation is dramatically reduced to 2.79 MHz in 3600 seconds, comparing with 34.1 MHz drift in the free running mode. In application, with the locked magic laser frequency, the heading error for laser pumped 4He magnetometer can be eliminated much. The National Science Fund for Distinguished Young Scholars of China (Grant No. 61225003), the National Natural Science Foundation of China (Grant No. 61101081), and the National Hi-Tech Research and Development (863) Program.
A comparative study on simulation performances of rigid and bendable SAW for gas sensor
NASA Astrophysics Data System (ADS)
Sidek, Fatini; Arsat, Rashidah; Ibrahim, Rafidah; Idris, Aizzat Ayuni Mohad; Johari, Zaharah; Ling, Leow Pei
2017-03-01
Flexible Surface Acoustic Wave (SAW) devices are very promising technology for various applications that offers excellent flexibility, low in cost and light weight. In this paper, a SAW gas sensor is designed and simulated using COMSOL Multiphysics to investigate the degree of bending effect on the frequency and displacement. The investigations were conducted onto SAW gas sensor as rigid and two different bends direction; bend-in (concave) and bend-out (convex). The operating frequency of the SAW sensor were found to be at the range of 80-200 MHz. The frequency shift of the sensor were obtained after exposing the polyisobutylene (PIB) to the dichloromethane DCM gas which will change the density of sensing layer. From the simulation, it is shown that resonance frequency range of 189MHz for the rigid substrate with displacement of 0.706 nm. Notably, the bending degree of h range from 0.2 µm to 1.25 µm exhibits reduction for displacement and frequency. The higher frequency of bend-out (convex) design achieve is 1.8945 MHz with displacement of 0.68 nm at curve of h= 0.2 µm, Improvement have been observed for the frequency shift of 14 Hz and sensitivity of 1324.24. It shows that the sensor is more sensitive to detect the gas. The evaluation of device bending effect on the eigenfrequency, displacement and frequency shift provide ways to enhance the sensitivity of the gas sensor and expand its possibility of realizing their benefit particularly for sensing device enhancement.
Kuznetsova, G D; Gabova, A V; Lazarev, I E; Obukhov, Iu V; Obukhov, K Iu; Morozov, A A; Kulikov, M A; Shchatskova, A B; Vasil'eva, O N; Tomilovskaia, E S
2015-01-01
Frequency-temporal electroencephalogram (EEG) reactions to hypogravity were studied in 7 male subjects at the age of 20 to 27 years. The experiment was conducted using dry immersion (DI) as the best known method of simulating the space microgravity effects on the Earth. This hypogravity model reproduces hypokinesia, i.e. the weight-bearing and mechanic load removal, which is typical of microgravity. EEG was recorded by Neuroscan-2 (Compumedics) before the experiment (baseline data) and at the end of day 2 in DI. Comparative analysis of the EEG frequency-temporal structure was performed with the use of 2 techniques: Fourier transform and modified wavelet analysis. The Fourier transform elicited that after 2 days in DI the main shifts occurring to the EEG spectral composition are a decline in the alpha power and a slight though reliable growth of theta power. Similar frequency shifts were detected in the same records analyzed using the wavelet transform. According to wavelet analysis, during DI shifts in EEG frequency spectrum are accompanied by frequency desorganization of the EEG dominant rhythm and gross impairment of total stability of the electrical activity with time. Wavelet transform provides an opportunity to quantify changes in the frequency-temporal structure of the electrical activity of the brain. Quantitative evidence of frequency desorganization and temporal instability of EEG wavelet spectrograms may be the key to the understanding of mechanisms that drive functional disorders in the brain cortex in the conditions of hypogravity.
The perceptual enhancement of tones by frequency shifts.
Demany, Laurent; Carcagno, Samuele; Semal, Catherine
2013-04-01
In a chord of pure tones with a flat spectral profile, one tone can be perceptually enhanced relative to the other tones by the previous presentation of a slightly different chord. "Intensity enhancement" (IE) is obtained when the component tones of the two chords have the same frequencies, but in the first chord the target of enhancement is attenuated relative to the other tones. "Frequency enhancement" (FE) is obtained when both chords have a flat spectral profile, but the target of enhancement shifts in frequency from the first to the second chord. We report here an experiment in which IE and FE were measured using a task requiring the listener to indicate whether or not the second chord included a tone identical to a subsequent probe tone. The results showed that a global attenuation of the first chord relative to the second chord disrupted IE more than FE. This suggests that the mechanisms of IE and FE are not the same. In accordance with this suggestion, computations of the auditory excitation patterns produced by the chords indicate that the mechanism of IE is not sufficient to explain FE for small frequency shifts. Copyright © 2013 Elsevier B.V. All rights reserved.
Higher-order differential phase shift keyed modulation
NASA Astrophysics Data System (ADS)
Vanalphen, Deborah K.; Lindsey, William C.
1994-02-01
Advanced modulation/demodulation techniques which are robust in the presence of phase and frequency uncertainties continue to be of interest to communication engineers. We are particularly interested in techniques which accommodate slow channel phase and frequency variations with minimal performance degradation and which alleviate the need for phase and frequency tracking loops in the receiver. We investigate the performance sensitivity to frequency offsets of a modulation technique known as binary Double Differential Phase Shift Keying (DDPSK) and compare it to that of classical binary Differential Phase Shift Keying (DPSK). We also generalize our analytical results to include n(sup -th) order, M-ary DPSK. The DDPSK (n = 2) technique was first introduced in the Russian literature circa 1972 and was studied more thoroughly in the late 1970's by Pent and Okunev. Here, we present an expression for the symbol error probability that is easy to derive and to evaluate numerically. We also present graphical results that establish when, as a function of signal energy-to-noise ratio and normalized frequency offset, binary DDPSK is preferable to binary DPSK with respect to performance in additive white Gaussian noise. Finally, we provide insight into the optimum receiver from a detection theory viewpoint.
Paparo, M.; Benko, J. M.; Hareter, M.; ...
2016-06-17
A sequence search method was developed for searching for regular frequency spacing in δ Scuti stars by visual inspection (VI) and algorithmic search. The sample contains 90 δ Scuti stars observed by CoRoT. An example is given to represent the VI. The algorithm (SSA) is described in detail. The data treatment of the CoRoT light curves, the criteria for frequency filtering, and the spacings derived by two methods (i.e., three approaches: VI, SSA, and FT) are given for each target. Echelle diagrams are presented for 77 targets for which at least one sequence of regular spacing was identified. Comparing the spacing and the shifts between pairs of echelle ridges revealed that at least one pair of echelle ridges is shifted to midway between the spacing for 22 stars. The estimated rotational frequencies compared to the shifts revealed rotationally split doublets, triplets, and multiplets not only for single frequencies, but for the complete echelle ridges in 31 δ Scuti stars. Furthermore, using several possible assumptions for the origin of the spacings, we derived the large separation (more » $${\\rm{\\Delta }}\
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paparo, M.; Benko, J. M.; Hareter, M.
A sequence search method was developed for searching for regular frequency spacing in δ Scuti stars by visual inspection (VI) and algorithmic search. The sample contains 90 δ Scuti stars observed by CoRoT. An example is given to represent the VI. The algorithm (SSA) is described in detail. The data treatment of the CoRoT light curves, the criteria for frequency filtering, and the spacings derived by two methods (i.e., three approaches: VI, SSA, and FT) are given for each target. Echelle diagrams are presented for 77 targets for which at least one sequence of regular spacing was identified. Comparing the spacing and the shifts between pairs of echelle ridges revealed that at least one pair of echelle ridges is shifted to midway between the spacing for 22 stars. The estimated rotational frequencies compared to the shifts revealed rotationally split doublets, triplets, and multiplets not only for single frequencies, but for the complete echelle ridges in 31 δ Scuti stars. Furthermore, using several possible assumptions for the origin of the spacings, we derived the large separation (more » $${\\rm{\\Delta }}\
Seven, Yasin B; Mantilla, Carlos B; Zhan, Wen-Zhi; Sieck, Gary C
2013-01-15
We hypothesized that a shift in diaphragm muscle (DIAm) EMG power spectral density (PSD) to higher frequencies reflects recruitment of more fatigable fast-twitch motor units and motor unit recruitment is reflected by EMG non-stationarity. DIAm EMG was recorded in anesthetized rats during eupnea, hypoxia-hypercapnia (10% O(2)-5% CO(2)), airway occlusion, and sneezing (maximal DIAm force). Although power in all frequency bands increased progressively across motor behaviors, PSD centroid frequency increased only during sneezing (p<0.05). The non-stationary period at the onset of EMG activity ranged from ∼80 ms during airway occlusion to ∼150 ms during eupnea. Within the initial non-stationary period of EMG activity 80-95% of motor units were recruited during different motor behaviors. Motor units augmented their discharge frequencies progressively beyond the non-stationary period; yet, EMG signal became stationary. In conclusion, non-stationarity of DIAm EMG reflects the period of motor unit recruitment, while a shift in the PSD towards higher frequencies reflects recruitment of more fatigable fast-twitch motor units. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hamdi, H.; Qausar, A. M.; Srigutomo, W.
2016-08-01
Controlled source audio-frequency magnetotellurics (CSAMT) is a frequency-domain electromagnetic sounding technique which uses a fixed grounded dipole as an artificial signal source. Measurement of CSAMT with finite distance between transmitter and receiver caused a complex wave. The shifted of the electric field due to the static effect caused elevated resistivity curve up or down and affects the result of measurement. The objective of this study was to obtain data that have been corrected for source and static effects as to have the same characteristic as MT data which are assumed to exhibit plane wave properties. Corrected CSAMT data were inverted to reveal subsurface resistivity model. Source effect correction method was applied to eliminate the effect of the signal source and static effect was corrected by using spatial filtering technique. Inversion method that used in this study is the Occam's 2D Inversion. The results of inversion produces smooth models with a small misfit value, it means the model can describe subsurface conditions well. Based on the result of inversion was predicted measurement area is rock that has high permeability values with rich hot fluid.
NASA Astrophysics Data System (ADS)
Baharudin, M. E.; Nor, A. M.; Saad, A. R. M.; Yusof, A. M.
2018-03-01
The motion of vibration-driven robots is based on an internal oscillating mass which can move without legs or wheels. The oscillation of the unbalanced mass by a motor is translated into vibration which in turn produces vertical and horizontal forces. Both vertical and horizontal oscillations are of the same frequency but the phases are shifted. The vertical forces will deflect the bristles which cause the robot to move forward. In this paper, the horizontal motion direction caused by the vertically vibrated bristle is numerically simulated by tuning the frequency of their oscillatory actuation. As a preliminary work, basic equations for a simple off-centered vibration location on the robot platform and simulation model for vibration excitement are introduced. It involves both static and dynamic vibration analysis of robots and analysis of different type of parameters. In addition, the orientation of the bristles and oscillators are also analysed. Results from the numerical integration seem to be in good agreement with those achieved from the literature. The presented numerical integration modeling can be used for designing the bristles and controlling the speed and direction of the robot.
Proton chemical shift tensors determined by 3D ultrafast MAS double-quantum NMR spectroscopy
NASA Astrophysics Data System (ADS)
Zhang, Rongchun; Mroue, Kamal H.; Ramamoorthy, Ayyalusamy
2015-10-01
Proton NMR spectroscopy in the solid state has recently attracted much attention owing to the significant enhancement in spectral resolution afforded by the remarkable advances in ultrafast magic angle spinning (MAS) capabilities. In particular, proton chemical shift anisotropy (CSA) has become an important tool for obtaining specific insights into inter/intra-molecular hydrogen bonding. However, even at the highest currently feasible spinning frequencies (110-120 kHz), 1H MAS NMR spectra of rigid solids still suffer from poor resolution and severe peak overlap caused by the strong 1H-1H homonuclear dipolar couplings and narrow 1H chemical shift (CS) ranges, which render it difficult to determine the CSA of specific proton sites in the standard CSA/single-quantum (SQ) chemical shift correlation experiment. Herein, we propose a three-dimensional (3D) 1H double-quantum (DQ) chemical shift/CSA/SQ chemical shift correlation experiment to extract the CS tensors of proton sites whose signals are not well resolved along the single-quantum chemical shift dimension. As extracted from the 3D spectrum, the F1/F3 (DQ/SQ) projection provides valuable information about 1H-1H proximities, which might also reveal the hydrogen-bonding connectivities. In addition, the F2/F3 (CSA/SQ) correlation spectrum, which is similar to the regular 2D CSA/SQ correlation experiment, yields chemical shift anisotropic line shapes at different isotropic chemical shifts. More importantly, since the F2/F1 (CSA/DQ) spectrum correlates the CSA with the DQ signal induced by two neighboring proton sites, the CSA spectrum sliced at a specific DQ chemical shift position contains the CSA information of two neighboring spins indicated by the DQ chemical shift. If these two spins have different CS tensors, both tensors can be extracted by numerical fitting. We believe that this robust and elegant single-channel proton-based 3D experiment provides useful atomistic-level structural and dynamical information for a variety of solid systems that possess high proton density.
Proton chemical shift tensors determined by 3D ultrafast MAS double-quantum NMR spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Rongchun; Mroue, Kamal H.; Ramamoorthy, Ayyalusamy, E-mail: ramamoor@umich.edu
2015-10-14
Proton NMR spectroscopy in the solid state has recently attracted much attention owing to the significant enhancement in spectral resolution afforded by the remarkable advances in ultrafast magic angle spinning (MAS) capabilities. In particular, proton chemical shift anisotropy (CSA) has become an important tool for obtaining specific insights into inter/intra-molecular hydrogen bonding. However, even at the highest currently feasible spinning frequencies (110–120 kHz), {sup 1}H MAS NMR spectra of rigid solids still suffer from poor resolution and severe peak overlap caused by the strong {sup 1}H–{sup 1}H homonuclear dipolar couplings and narrow {sup 1}H chemical shift (CS) ranges, which rendermore » it difficult to determine the CSA of specific proton sites in the standard CSA/single-quantum (SQ) chemical shift correlation experiment. Herein, we propose a three-dimensional (3D) {sup 1}H double-quantum (DQ) chemical shift/CSA/SQ chemical shift correlation experiment to extract the CS tensors of proton sites whose signals are not well resolved along the single-quantum chemical shift dimension. As extracted from the 3D spectrum, the F1/F3 (DQ/SQ) projection provides valuable information about {sup 1}H–{sup 1}H proximities, which might also reveal the hydrogen-bonding connectivities. In addition, the F2/F3 (CSA/SQ) correlation spectrum, which is similar to the regular 2D CSA/SQ correlation experiment, yields chemical shift anisotropic line shapes at different isotropic chemical shifts. More importantly, since the F2/F1 (CSA/DQ) spectrum correlates the CSA with the DQ signal induced by two neighboring proton sites, the CSA spectrum sliced at a specific DQ chemical shift position contains the CSA information of two neighboring spins indicated by the DQ chemical shift. If these two spins have different CS tensors, both tensors can be extracted by numerical fitting. We believe that this robust and elegant single-channel proton-based 3D experiment provides useful atomistic-level structural and dynamical information for a variety of solid systems that possess high proton density.« less
Development of Michelson interferometer based spatial phase-shift digital shearography
NASA Astrophysics Data System (ADS)
Xie, Xin
Digital shearography is a non-contact, full field, optical measurement method, which has the capability of directly measuring the gradient of deformation. For high measurement sensitivity, phase evaluation method has to be introduced into digital shearography by phase-shift technique. Catalog by phase-shift method, digital phase-shift shearography can be divided into Temporal Phase-Shift Digital Shearography (TPS-DS) and Spatial Phase-Shift Digital Shearography (SPS-DS). TPS-DS is the most widely used phase-shift shearography system, due to its simple algorithm, easy operation and good phase-map quality. However, the application of TPS-DS is only limited in static/step-by-step loading measurement situation, due to its multi-step shifting process. In order to measure the strain under dynamic/continuous loading situation, a SPS-DS system has to be developed. This dissertation aims to develop a series of Michelson Interferometer based SPS-DS measurement methods to achieve the strain measurement by using only a single pair of speckle pattern images. The Michelson Interferometer based SPS-DS systems utilize special designed optical setup to introduce extra carrier frequency into the laser wavefront. The phase information corresponds to the strain field can be separated on the Fourier domain using a Fourier Transform and can further be evaluated with a Windowed Inverse Fourier Transform. With different optical setups and carrier frequency arrangements, the Michelson Interferometer based SPS-DS method is capable to achieve a variety of measurement tasks using only single pair of speckle pattern images. Catalog by the aimed measurand, these capable measurement tasks can be divided into five categories: 1) measurement of out-of-plane strain field with small shearing amount; 2) measurement of relative out-of-plane deformation field with big shearing amount; 3) simultaneous measurement of relative out-of-plane deformation field and deformation gradient field by using multiple carrier frequencies; 4) simultaneous measurement of two directional strain field using dual measurement channels 5) measurement of pure in-plane strain and pure out-of-plane strain with multiple carrier frequencies. The basic theory, optical path analysis, preliminary studies, results analysis and research plan are shown in detail in this dissertation.
Causes and Solutions of the Trampoline Effect.
Miwa, Masamiki; Ota, Noboru; Ando, Chiyono; Miyazaki, Yukio
2015-01-01
A trampoline effect may occur mainly when a buttonhole tract and the vessel flap fail to form a straight line. Certain findings, however, suggest another cause is when the vessel flap is too small. The frequency of the trampoline effect, for example, is lower when a buttonhole tract is created by multiple punctures of the arteriovenous fistula (AVF) vessel than when it is done by one-time puncture of the vessel. Lower frequency of the trampoline effect with multiple punctures of the AVF vessel may be due to enlargement of the initial puncture hole on the vessel every time the vessel is punctured with a sharp needle. Even if aiming at exactly the same point on the AVF vessel every time, the actual puncture point shifts slightly at every puncture, which potentially results in enlargement of the initial hole on the AVF vessel. Moreover, in some patients, continued use of a buttonhole tract for an extended period of time increases the frequency of the trampoline effect. In such cases, reduction of the incidence of the trampoline effect can be achieved by one buttonhole cannulation using a new dull needle with sharp side edges that is used to enlarge the vessel flap. Such single buttonhole cannulation may suggest that the increased frequency of the trampoline effect also potentially occurs in association with gradually diminishing flap size. As a final observation, dull needle insertion into a vessel flap in the reverse direction has been more smoothly achieved than insertion into a vessel flap in the conventional direction. A vessel flap in the reverse direction can be adopted clinically. © 2015 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Zhanlong; College of Physics, Jilin University, Changchun 130012; Shan Xiaoning
2012-07-09
The current paper investigates stimulated Raman scattering (SRS) when laser-induced plasma is formed in heavy water by focusing an intense pulsed 532 nm Nd:YAG laser beam at room temperature. An unexpected low-frequency SRS line attributed to the lattice translational modes of ice-VII (D{sub 2}O) is observed. The pressure of the plasma shockwave is estimated using low-frequency SRS line shift.
Simulation of Dual-Electrode Capacitively Coupled Plasma Discharges
NASA Astrophysics Data System (ADS)
Lu, Yijia; Ji, Linhong; Cheng, Jia
2016-12-01
Dual-electrode capacitively coupled plasma discharges are investigated here to lower the non-uniformity of plasma density. The dual-electrode structure proposed by Jung splits the electrode region and increases the flexibility of fine tuning non-uniformity. Different RF voltages, frequencies, phase-shifts and electrode areas are simulated and the influences are discussed. RF voltage and electrode area have a non-monotonic effect on non-uniformity, while frequency has a monotonic effect. Phase-shift has a cyclical influence on non-uniformity. A special combination of 224 V voltage and 11% area ratio with 10 MHz lowers the non-uniformity of the original set (200 V voltage and 0% area ratio with 10 MHz) by 46.5%. The position of the plasma density peak at the probe line has been tracked and properly tuning the phase-shift can obtain the same trace as tuning frequency or voltage. supported by National Natural Science Foundation of China (No. 51405261)
Nuclear spin noise in NMR revisited
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferrand, Guillaume; Luong, Michel; Huber, Gaspard
2015-09-07
The theoretical shapes of nuclear spin-noise spectra in NMR are derived by considering a receiver circuit with finite preamplifier input impedance and a transmission line between the preamplifier and the probe. Using this model, it becomes possible to reproduce all observed experimental features: variation of the NMR resonance linewidth as a function of the transmission line phase, nuclear spin-noise signals appearing as a “bump” or as a “dip” superimposed on the average electronic noise level even for a spin system and probe at the same temperature, pure in-phase Lorentzian spin-noise signals exhibiting non-vanishing frequency shifts. Extensive comparisons to experimental measurementsmore » validate the model predictions, and define the conditions for obtaining pure in-phase Lorentzian-shape nuclear spin noise with a vanishing frequency shift, in other words, the conditions for simultaneously obtaining the spin-noise and frequency-shift tuning optima.« less
Microcantilever-based gas sensor employing two simultaneous physical sensing modes
Loui, Albert; Sirbuly, Donald J; Elhadj, Selim; McCall, Scott K; Hart, Bradley R; Ratto, Timothy V
2014-06-24
According to one embodiment, a system for detecting and identifying gases includes a piezoresistive microcantilever transducer, wherein dissipation of heat from the piezoresistive microcantilever into one or more gases is measured by changes in an electrical resistance of the piezoresistor, a vibrating microcantilever transducer, wherein shifts are measured in resonant frequency of the vibrating microcantilever due to viscous damping thereof by the one or more gases, and a subsystem for correlating the measured resistance changes and the resonant frequency shifts to the one or more gases. In another embodiment, a method for detecting and identifying one or more gases includes determining dissipation of heat from a microcantilever into one or more gases, and determining shifts in resonant frequency of the microcantilever due to viscous damping thereof by the one or more gases. Other systems, methods, and computer program products are also described according to more embodiments.
Improved frequency/voltage converters for fast quartz crystal microbalance applications.
Torres, R; García, J V; Arnau, A; Perrot, H; Kim, L To Thi; Gabrielli, C
2008-04-01
The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1 kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10 mVHz, for a frequency shift resolution of 0.1 Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5 to 10 MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.
Improved frequency/voltage converters for fast quartz crystal microbalance applications
NASA Astrophysics Data System (ADS)
Torres, R.; García, J. V.; Arnau, A.; Perrot, H.; Kim, L. To Thi; Gabrielli, C.
2008-04-01
The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10mV/Hz, for a frequency shift resolution of 0.1Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5to10MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.
Terahertz microfluidic sensing using a parallel-plate waveguide sensor.
Astley, Victoria; Reichel, Kimberly; Mendis, Rajind; Mittleman, Daniel M
2012-08-30
Refractive index (RI) sensing is a powerful noninvasive and label-free sensing technique for the identification, detection and monitoring of microfluidic samples with a wide range of possible sensor designs such as interferometers and resonators. Most of the existing RI sensing applications focus on biological materials in aqueous solutions in visible and IR frequencies, such as DNA hybridization and genome sequencing. At terahertz frequencies, applications include quality control, monitoring of industrial processes and sensing and detection applications involving nonpolar materials. Several potential designs for refractive index sensors in the terahertz regime exist, including photonic crystal waveguides, asymmetric split-ring resonators, and photonic band gap structures integrated into parallel-plate waveguides. Many of these designs are based on optical resonators such as rings or cavities. The resonant frequencies of these structures are dependent on the refractive index of the material in or around the resonator. By monitoring the shifts in resonant frequency the refractive index of a sample can be accurately measured and this in turn can be used to identify a material, monitor contamination or dilution, etc. The sensor design we use here is based on a simple parallel-plate waveguide. A rectangular groove machined into one face acts as a resonant cavity (Figures 1 and 2). When terahertz radiation is coupled into the waveguide and propagates in the lowest-order transverse-electric (TE1) mode, the result is a single strong resonant feature with a tunable resonant frequency that is dependent on the geometry of the groove. This groove can be filled with nonpolar liquid microfluidic samples which cause a shift in the observed resonant frequency that depends on the amount of liquid in the groove and its refractive index. Our technique has an advantage over other terahertz techniques in its simplicity, both in fabrication and implementation, since the procedure can be accomplished with standard laboratory equipment without the need for a clean room or any special fabrication or experimental techniques. It can also be easily expanded to multichannel operation by the incorporation of multiple grooves. In this video we will describe our complete experimental procedure, from the design of the sensor to the data analysis and determination of the sample refractive index.
Thermal emission and absorption of radiation in finite inverted-opal photonic crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Florescu, Marian; Stimpson, Andrew J.; Lee, Hwang
We study theoretically the optical properties of a finite inverted-opal photonic crystal. The light-matter interaction is strongly affected by the presence of the three-dimensional photonic crystal and the alterations of the light emission and absorption processes can be used to suppress or enhance the thermal emissivity and absorptivity of the dielectric structure. We investigate the influence of the absorption present in the system on the relevant band edge frequencies that control the optical response of the photonic crystal. Our study reveals that the absorption processes cause spectral broadening and shifting of the band edge optical resonances, and determine a strongmore » reduction of the photonic band gap spectral range. Using the angular and spectral dependence of the band edge frequencies for stop bands along different directions, we argue that by matching the blackbody emission spectrum peak with a prescribed maximum of the absorption coefficient, it is possible to achieve an angle-sensitive enhancement of the thermal emission/absorption of radiation. This result opens a way to realize a frequency-sensitive and angle-sensitive photonic crystal absorbers/emitters.« less
LTP interferometer—noise sources and performance
NASA Astrophysics Data System (ADS)
Robertson, David; Killow, Christian; Ward, Harry; Hough, Jim; Heinzel, Gerhard; Garcia, Antonio; Wand, Vinzenz; Johann, Ulrich; Braxmaier, Claus
2005-05-01
The LISA Technology Package (LTP) uses laser interferometry to measure the changes in relative displacement between two inertial test masses. The goals of the mission require a displacement measuring precision of 10 pm Hz-1/2 at frequencies in the 3 30 mHz band. We report on progress with a prototype LTP interferometer optical bench in which fused silica mirrors and beamsplitters are fixed to a ZERODUR® substrate using hydroxide catalysis bonding to form a rigid interferometer. The couplings to displacement noise of this interferometer of two expected noise sources—laser frequency noise and ambient temperature fluctuations—have been investigated, and an additional, unexpected, noise source has been identified. The additional noise is due to small amounts of signal at the heterodyne frequency arriving at the photodiode preamplifiers with a phase that quasistatically changes with respect to the optical signal. The phase shift is caused by differential changes in the external optical paths the beams travel before they reach the rigid interferometer. Two different external path length stabilization systems have been demonstrated and these allowed the performance of the overall system to meet the LTP displacement noise requirement.
Fire forbids fifty-fifty forest
Staal, Arie; Hantson, Stijn; Holmgren, Milena; Pueyo, Salvador; Bernardi, Rafael E.; Flores, Bernardo M.; Xu, Chi; Scheffer, Marten
2018-01-01
Recent studies have interpreted patterns of remotely sensed tree cover as evidence that forest with intermediate tree cover might be unstable in the tropics, as it will tip into either a closed forest or a more open savanna state. Here we show that across all continents the frequency of wildfires rises sharply as tree cover falls below ~40%. Using a simple empirical model, we hypothesize that the steepness of this pattern causes intermediate tree cover (30‒60%) to be unstable for a broad range of assumptions on tree growth and fire-driven mortality. We show that across all continents, observed frequency distributions of tropical tree cover are consistent with this hypothesis. We argue that percolation of fire through an open landscape may explain the remarkably universal rise of fire frequency around a critical tree cover, but we show that simple percolation models cannot predict the actual threshold quantitatively. The fire-driven instability of intermediate states implies that tree cover will not change smoothly with climate or other stressors and shifts between closed forest and a state of low tree cover will likely tend to be relatively sharp and difficult to reverse. PMID:29351323
Fire forbids fifty-fifty forest.
van Nes, Egbert H; Staal, Arie; Hantson, Stijn; Holmgren, Milena; Pueyo, Salvador; Bernardi, Rafael E; Flores, Bernardo M; Xu, Chi; Scheffer, Marten
2018-01-01
Recent studies have interpreted patterns of remotely sensed tree cover as evidence that forest with intermediate tree cover might be unstable in the tropics, as it will tip into either a closed forest or a more open savanna state. Here we show that across all continents the frequency of wildfires rises sharply as tree cover falls below ~40%. Using a simple empirical model, we hypothesize that the steepness of this pattern causes intermediate tree cover (30‒60%) to be unstable for a broad range of assumptions on tree growth and fire-driven mortality. We show that across all continents, observed frequency distributions of tropical tree cover are consistent with this hypothesis. We argue that percolation of fire through an open landscape may explain the remarkably universal rise of fire frequency around a critical tree cover, but we show that simple percolation models cannot predict the actual threshold quantitatively. The fire-driven instability of intermediate states implies that tree cover will not change smoothly with climate or other stressors and shifts between closed forest and a state of low tree cover will likely tend to be relatively sharp and difficult to reverse.
NASA Astrophysics Data System (ADS)
Zhou, Lei; Li, Zhengying; Xiang, Na; Bao, Xiaoyi
2018-06-01
A high speed quasi-distributed demodulation method based on the microwave photonics and the chromatic dispersion effect is designed and implemented for weak fiber Bragg gratings (FBGs). Due to the effect of dispersion compensation fiber (DCF), FBG wavelength shift leads to the change of the difference frequency signal at the mixer. With the way of crossing microwave sweep cycle, all wavelengths of cascade FBGs can be high speed obtained by measuring the frequencies change. Moreover, through the introduction of Chirp-Z and Hanning window algorithm, the analysis of difference frequency signal is achieved very well. By adopting the single-peak filter as a reference, the length disturbance of DCF caused by temperature can be also eliminated. Therefore, the accuracy of this novel method is greatly improved, and high speed demodulation of FBGs can easily realize. The feasibility and performance are experimentally demonstrated using 105 FBGs with 0.1% reflectivity, 1 m spatial interval. Results show that each grating can be distinguished well, and the demodulation rate is as high as 40 kHz, the accuracy is about 8 pm.
Modeling the Effects of Fire Frequency and Severity on Forests in the Northwestern United States
Busing, Richard T.; Solomon, Allen M.
2006-01-01
This study used a model of forest dynamics (FORCLIM) and actual forest survey data to demonstrate the effects of various fire regimes on different forest types in the Pacific Northwest. We examined forests in eight ecoregions ranging from wet coastal forests dominated by Pseudotsuga menziesii and other tall conifers to dry interior forests dominated by Pinus ponderosa. Fire effects simulated as elevated mortality of trees based on their species and size did alter forest structure and species composition. Low frequency fires characteristic of wetter forests (return interval >200 yr) had minor effects on composition. When fires were severe, they tended to reduce total basal area with little regard to species differences. High frequency fires characteristic of drier forests (return interval <30 yr) had major effects on species composition and on total basal area. Typically, they caused substantial reductions in total basal area and shifts in dominance toward highly fire tolerant species. With the addition of fire, simulated basal areas averaged across ecoregions were reduced to levels approximating observed basal areas.
Regional dry-season climate changes due to three decades of Amazonian deforestation
NASA Astrophysics Data System (ADS)
Khanna, Jaya; Medvigy, David; Fueglistaler, Stephan; Walko, Robert
2017-02-01
More than 20% of the Amazon rainforest has been cleared in the past three decades, triggering important hydroclimatic changes. Small-scale (a few kilometres) deforestation in the 1980s has caused thermally triggered atmospheric circulations that increase regional cloudiness and precipitation frequency. However, these circulations are predicted to diminish as deforestation increases. Here we use multi-decadal satellite records and numerical model simulations to show a regime shift in the regional hydroclimate accompanying increasing deforestation in Rondônia, Brazil. Compared with the 1980s, present-day deforested areas in downwind western Rondônia are found to be wetter than upwind eastern deforested areas during the local dry season. The resultant precipitation change in the two regions is approximately +/-25% of the deforested area mean. Meso-resolution simulations robustly reproduce this transition when forced with increasing deforestation alone, showing that large-scale climate variability plays a negligible role. Furthermore, deforestation-induced surface roughness reduction is found to play an essential role in the present-day dry-season hydroclimate. Our study illustrates the strong scale sensitivity of the climatic response to Amazonian deforestation and suggests that deforestation is sufficiently advanced to have caused a shift from a thermally to a dynamically driven hydroclimatic regime.
Laser frequency modulation with electron plasma
NASA Technical Reports Server (NTRS)
Burgess, T. J.; Latorre, V. R.
1972-01-01
When laser beam passes through electron plasma its frequency shifts by amount proportional to plasma density. This density varies with modulating signal resulting in corresponding modulation of laser beam frequency. Necessary apparatus is relatively inexpensive since crystals are not required.
Welding Experiments of Aluminum Alloy by Space GHTA Welding at ISS Orbital Pressure
NASA Astrophysics Data System (ADS)
Suita, Yoshikazu; Takai, Daisuke; Sugiyama, Satoshi; Terajima, Noboru; Tsukuda, Yoshiyuki; Fujisawa, Shoichiro; Imagawa, Kichiro
As a feasible welding method in space, the authors previously proposed the space GHTA (Gas Hollow Tungsten Arc) welding process. However, space GHTA welding with a high-frequency device for arc start may cause electromagnetic noise problems for the computer equipment placed on the ISS (International Space Station). Therefore, in this report, welding experiments of space GHTA welding using aluminum alloy with a high-voltage DC device for arc start were carried out at the ISS orbital pressure, 10-5 Pa. It is clear from the experiments using a high-voltage DC device in a high-vacuum condition, that there is a shifting phenomenon in which the spark discharge shifts to either a glow discharge or an arc discharge when starting the arc. Welding projects in space need an arc discharge, so we investigated the effects of welding parameters on the arc formation ratio. As a result, space GHTA welding with a high-voltage DC device can be used for arc start when welding at the ISS orbital pressure.
What is the temporal analog of reflection and refraction of optical beams?
Plansinis, B. W.; Donaldson, W. R.; Agrawal, G. P.
2015-10-28
It is shown numerically and analytically that when an optical pulse approaches a moving temporal boundary across which the refractive index changes, it undergoes a temporal equivalent of reflection and refraction of optical beams at a spatial boundary. The main difference is that the role of angles is played by changes in the frequency. The frequency dependence of the dispersion of the material in which the pulse is propagating plays a fundamental role in determining the frequency shifts experienced by the reflected and refracted pulses. As a result, our analytic expressions for these frequency shifts allow us to find themore » condition under which an analog of total internal reflection may occur at the temporal boundary.« less
Brillouin lasing in coupled silica toroid microcavities
NASA Astrophysics Data System (ADS)
Honda, Yoshihiro; Yoshiki, Wataru; Tetsumoto, Tomohiro; Fujii, Shun; Furusawa, Kentaro; Sekine, Norihiko; Tanabe, Takasumi
2018-05-01
We demonstrate stimulated Brillouin scattering lasing in a strongly coupled microcavity system. By coupling two silica toroid microcavities, we achieve large mode splitting of 11 GHz, whose frequency separation matches the Brillouin frequency shift of silica. The stimulated Brillouin scattering light is resonantly amplified by pumping at the higher frequency side of the supermode splitting resonance. Since the mode splitting is adjusted by changing the gap distance between the two cavities, our system does not require precise control of a mm-sized cavity diameter to match the free-spectral spacing with the Brillouin frequency shift. It also allows us to use a small cavity, and hence, our system has the potential to achieve the lasing threshold at a very low power.
Kabara, J F; Bonds, A B
2001-12-01
Responses of cat striate cortical cells to a drifting sinusoidal grating were modified by the superimposition of a second, perturbing grating (PG) that did not excite the cell when presented alone. One consequence of the presence of a PG was a shift in the tuning curves. The orientation tuning of all 41 cells exposed to a PG and the spatial frequency tuning of 83% of the 23 cells exposed to a PG showed statistically significant dislocations of both the response function peak and center of mass from their single grating values. As found in earlier reports, the presence of PGs suppressed responsiveness. However, reductions measured at the single grating optimum orientation or spatial frequency were on average 1.3 times greater than the suppression found at the peak of the response function modified by the presence of the PG. Much of the loss in response seen at the single grating optimum is thus a result of a shift in the tuning function rather than outright suppression. On average orientation shifts were repulsive and proportional (approximately 0.10 deg/deg) to the angle between the perturbing stimulus and the optimum single grating orientation. Shifts in the spatial frequency response function were both attractive and repulsive, resulting in an overall average of zero. For both simple and complex cells, PGs generally broadened orientation response function bandwidths. Similarly, complex cell spatial frequency response function bandwidths broadened. Simple cell spatial frequency response functions usually did not change, and those that did broadened only 4% on average. These data support the hypothesis that additional sinusoidal components in compound stimuli retune cells' response functions for orientation and spatial frequency.
Adiabatic perturbation theory for atoms and molecules in the low-frequency regime
NASA Astrophysics Data System (ADS)
Martiskainen, Hanna; Moiseyev, Nimrod
2017-12-01
There is an increasing interest in the photoinduced dynamics in the low frequency, ω, regime. The multiphoton absorptions by molecules in strong laser fields depend on the polarization of the laser and on the molecular structure. The unique properties of the interaction of atoms and molecules with lasers in the low-frequency regime imply new concepts and directions in strong-field light-matter interactions. Here we represent a perturbational approach for the calculations of the quasi-energy spectrum in the low-frequency regime, which avoids the construction of the Floquet operator with extremely large number of Floquet channels. The zero-order Hamiltonian in our perturbational approach is the adiabatic Hamiltonian where the atoms/molecules are exposed to a dc electric field rather than to ac-field. This is in the spirit of the first step in the Corkum three-step model. The second-order perturbation correction terms are obtained when i ℏ ω ∂/∂ τ serves as a perturbation and τ is a dimensionless variable. The second-order adiabatic perturbation scheme is found to be an excellent approach for calculating the ac-field Floquet solutions in our test case studies of a simple one-dimensional time-periodic model Hamiltonian. It is straightforward to implement the perturbation approach presented here for calculating atomic and molecular energy shifts (positions) due to the interaction with low-frequency ac-fields using high-level electronic structure methods. This is enabled since standard quantum chemistry packages allow the calculations of atomic and molecular energy shifts due to the interaction with dc-fields. In addition to the shift of the energy positions, the energy widths (inverse lifetimes) can be obtained at the same level of theory. These energy shifts are functions of the laser parameters (low frequency, intensity, and polarization).
Optimum Detection Of Slow-Frequency-Hopping Signals
NASA Technical Reports Server (NTRS)
Levitt, Barry K.; Cheng, Unjeng
1994-01-01
Two papers present theoretical analyses of various schemes for coherent and noncoherent detection of M-ary-frequency-shift-keyed (MFSK) signals with slow frequency hopping. Special attention focused on continuous-phase-modulation (CPM) subset of SFH/MFSK signals, for which frequency modulation such carrier phase remains continuous (albeit unknown) during each hop.
Temporal Integration Windows in Neural Processing and Perception Aligned to Saccadic Eye Movements.
Wutz, Andreas; Muschter, Evelyn; van Koningsbruggen, Martijn G; Weisz, Nathan; Melcher, David
2016-07-11
When processing dynamic input, the brain balances the opposing needs of temporal integration and sensitivity to change. We hypothesized that the visual system might resolve this challenge by aligning integration windows to the onset of newly arriving sensory samples. In a series of experiments, human participants observed the same sequence of two displays separated by a brief blank delay when performing either an integration or segregation task. First, using magneto-encephalography (MEG), we found a shift in the stimulus-evoked time courses by a 150-ms time window between task signals. After stimulus onset, multivariate pattern analysis (MVPA) decoding of task in occipital-parietal sources remained above chance for almost 1 s, and the task-decoding pattern interacted with task outcome. In the pre-stimulus period, the oscillatory phase in the theta frequency band was informative about both task processing and behavioral outcome for each task separately, suggesting that the post-stimulus effects were caused by a theta-band phase shift. Second, when aligning stimulus presentation to the onset of eye fixations, there was a similar phase shift in behavioral performance according to task demands. In both MEG and behavioral measures, task processing was optimal first for segregation and then integration, with opposite phase in the theta frequency range (3-5 Hz). The best fit to neurophysiological and behavioral data was given by a dampened 3-Hz oscillation from stimulus or eye fixation onset. The alignment of temporal integration windows to input changes found here may serve to actively organize the temporal processing of continuous sensory input. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Son, Mia; Sung, Juhon; Yum, Myunggul; Kong, Jung Ok; Lee, Hye Un; Kim, In A; Kim, Jung Yeon
2004-05-01
The objective of this study is to compare the circadian patterns of heart rate variability assessed by 24-hour ambulatory electrocardiographic (ECG) recordings during day shift and night shift among the workers in the 5 days-concecutive- 12-hour shift in an automobile factory in Korea. The study population consisted 300 workers, who were randomly selected among the 8700 total workers in one car factory. To analyse circadian variation, the 24-hour ECG recordings (Marquette) were measured during day shift (08: 00-20: 00 h) and night shift (20: 00-08: 00 h). Analysis was performed for all time and frequency domain measures of HRV. 233 workers completed taking 24-hour ECG recordings. This study shows that the 24 hourcircadian variation mainly follows work/sleep cycle rather than day/night cycle among shift workers. This study also shows that among the night shift, the circadian variation between work and sleep cycle decreased compared to the work/sleep cycle among day shift workers. All time and frequency domain parameters (except LF/HF ratio) show significantly different between work and sleep in the day shift and night shift. These changes in heart rate variability circadian rhythms reflect significant reductions in cardiac parasympathetic activity with the most marked reduction in normal vagal activity among the shift workers. Especially, it suggests the circadian rhytm has blunted among the night workers. The quantification of the circadian variation in HRV can be a surrogates of workers' potential health risk, as well as suggests possible mechanisms through which the shift works compromise workers' health.
Coherent multi-heterodyne spectroscopy using acousto-optic frequency combs.
Durán, Vicente; Schnébelin, Cȏme; Guillet de Chatellus, Hugues
2018-05-28
We propose and characterize experimentally a new source of optical frequency combs for performing multi-heterodyne spectrometry. This comb modality is based on a frequency-shifting loop seeded with a continuous-wave (CW) monochromatic laser. The comb lines are generated by successive passes of the CW laser through an acousto-optic frequency shifter. We report the generation of frequency combs with more than 1500 mutually coherent lines, without resorting to non-linear broadening phenomena or external electronic modulation. The comb line spacing is easily reconfigurable from tens of MHz down to the kHz region. We first use a single acousto-optic frequency comb to conduct self-heterodyne interferometry with a high frequency resolution (500 kHz). By increasing the line spacing to 80 MHz, we demonstrate molecular spectroscopy on the sub-millisecond time scale. In order to reduce the detection bandwidth, we subsequently implement an acousto-optic dual-comb spectrometer with the aid of two mutually coherent frequency shifting loops. In each architecture, the potentiality of acousto-optic frequency combs for spectroscopy is validated by spectral measurements of hydrogen cyanide in the near-infrared region.
Coherent multi-heterodyne spectroscopy using acousto-optic frequency combs
NASA Astrophysics Data System (ADS)
Durán, Vicente; Schnébelin, Cȏme; Guillet de Chatellus, Hugues
2018-05-01
We propose and characterize experimentally a new source of optical frequency combs for performing multi-heterodyne spectrometry. This comb modality is based on a frequency shifting loop seeded with a CW monochromatic laser. The comb lines are generated by successive passes of the CW laser through an acousto-optic frequency shifter. We report the generation of frequency combs with more than 1500 mutually coherent lines, without resorting to non-linear broadening phenomena or external electronic modulation. The comb line spacing is easily reconfigurable from tens of MHz down to the kHz region. We first use a single acousto-optic frequency comb to conduct self-heterodyne interferometry with a high frequency resolution (500 kHz). By increasing the line spacing to 80 MHz, we demonstrate molecular spectroscopy on the sub-millisecond time scale. In order to reduce the detection bandwidth, we subsequently implement an acousto-optic dual-comb spectrometer with the aid of two mutually coherent frequency shifting loops. In each architecture, the potentiality of acousto-optic frequency combs for spectroscopy is validated by spectral measurements of hydrogen cyanide in the near-infrared region.
Confocal Fabry-Perot interferometer for frequency stabilization of laser
NASA Astrophysics Data System (ADS)
Pan, H.-J.; Ruan, P.; Wang, H.-W.; Li, F.
2011-02-01
The frequency shift of laser source of Doppler lidar is required in the range of a few megahertzs. To satisfy this demand, a confocal Fabry-Perot (F-P) interferometer was manufactured as the frequency standard for frequency stabilization. After analyzing and contrasting the center frequency shift of confocal Fabry-Perot interferometers that are made of three different types of material with the change of temperature, the zerodur material was selected to fabricate the interferometer, and the cavity mirrors were optically contacted onto the end of spacer. The confocal Fabry-Perot interferometer was situated within a double-walled chamber, and the change of temperature in the chamber was less than 0.01 K. The experimental results indicate that the free spectral range is 500 MHz, the full-width at half maximum is 3.33 MHz, and the finesse is 150.
Jakovac, Catarina Conte; Dutrieux, Loïc Paul; Siti, Latifah; Peña-Claros, Marielos; Bongers, Frans
2017-01-01
Shifting cultivation is the main land-use system transforming landscapes in riverine Amazonia. Increased concentration of the human population around villages and increasing market integration during the last decades may be causing agricultural intensification. Studies have shown that agricultural intensification, i.e. higher number of swidden-fallow cycles and shorter fallow periods, reduces crop productivity of swiddens and the regrowth capacity of fallows, undermining the resilience of the shifting cultivation system as a whole. We investigated the temporal and spatial dynamics of shifting cultivation in Brazilian Amazonia to test the hypotheses that (i) agriculture has become more intensive over time, and (ii) patterns of land-use intensity are related to land accessibility and human population density. We applied a breakpoint-detection algorithm to Landsat time-series spanning three decades (1984-2015) and retrieved the temporal dynamics of shifting cultivation fields, which go through alternating phases of crop production (swidden) and secondary forest regrowth (fallow). We found that fallow-period length has decreased from 6.4 to 5.1 years on average, and that expansion over old-growth forest has slowed down over time. Shorter fallow periods and higher frequency of slash and burn cycles are practiced closer to residences and around larger villages. Our results indicate that shifting cultivation in riverine Amazonia has gone through a process of agricultural intensification in the past three decades. The resulting landscape is predominantly covered by young secondary forests (≤ 12 yrs old), and 20% of it have gone through intensive use. Reversing this trend and avoiding the negative consequences of agricultural intensification requires land use planning that accounts for the constraints of land use in riverine areas.
Dutrieux, Loïc Paul; Siti, Latifah; Peña-Claros, Marielos; Bongers, Frans
2017-01-01
Shifting cultivation is the main land-use system transforming landscapes in riverine Amazonia. Increased concentration of the human population around villages and increasing market integration during the last decades may be causing agricultural intensification. Studies have shown that agricultural intensification, i.e. higher number of swidden-fallow cycles and shorter fallow periods, reduces crop productivity of swiddens and the regrowth capacity of fallows, undermining the resilience of the shifting cultivation system as a whole. We investigated the temporal and spatial dynamics of shifting cultivation in Brazilian Amazonia to test the hypotheses that (i) agriculture has become more intensive over time, and (ii) patterns of land-use intensity are related to land accessibility and human population density. We applied a breakpoint-detection algorithm to Landsat time-series spanning three decades (1984–2015) and retrieved the temporal dynamics of shifting cultivation fields, which go through alternating phases of crop production (swidden) and secondary forest regrowth (fallow). We found that fallow-period length has decreased from 6.4 to 5.1 years on average, and that expansion over old-growth forest has slowed down over time. Shorter fallow periods and higher frequency of slash and burn cycles are practiced closer to residences and around larger villages. Our results indicate that shifting cultivation in riverine Amazonia has gone through a process of agricultural intensification in the past three decades. The resulting landscape is predominantly covered by young secondary forests (≤ 12 yrs old), and 20% of it have gone through intensive use. Reversing this trend and avoiding the negative consequences of agricultural intensification requires land use planning that accounts for the constraints of land use in riverine areas. PMID:28727828
NASA Astrophysics Data System (ADS)
Zhang, Guannan; Schilling, Franz; Glaser, Steffen J.; Hilty, Christian
2016-11-01
Off-resonance decoupling using the method of Scaling of Heteronuclear Couplings by Optimal Tracking (SHOT) enables determination of heteronuclear correlations of chemical shifts in single scan NMR spectra. Through modulation of J-coupling evolution by shaped radio frequency pulses, off resonance decoupling using SHOT pulses causes a user-defined dependence of the observed J-splitting, such as the splitting of 13C peaks, on the chemical shift offset of coupled nuclei, such as 1H. Because a decoupling experiment requires only a single scan, this method is suitable for characterizing on-going chemical reactions using hyperpolarization by dissolution dynamic nuclear polarization (D-DNP). We demonstrate the calculation of [13C, 1H] chemical shift correlations of the carbanionic active sites from hyperpolarized styrene polymerized using sodium naphthalene as an initiator. While off resonance decoupling by SHOT pulses does not enhance the resolution in the same way as a 2D NMR spectrum would, the ability to obtain the correlations in single scans makes this method ideal for determination of chemical shifts in on-going reactions on the second time scale. In addition, we present a novel SHOT pulse that allows to scale J-splittings 50% larger than the respective J-coupling constant. This feature can be used to enhance the resolution of the indirectly detected chemical shift and reduce peak overlap, as demonstrated in a model reaction between p-anisaldehyde and isobutylamine. For both pulses, the accuracy is evaluated under changing signal-to-noise ratios (SNR) of the peaks from reactants and reaction products, with an overall standard deviation of chemical shift differences compared to reference spectra of 0.02 ppm when measured on a 400 MHz NMR spectrometer. Notably, the appearance of decoupling side-bands, which scale with peak intensity, appears to be of secondary importance.
Ototraumatic Effects of Hard Rock Music
Reddell, Rayford C.; Lebo, Charles P.
1972-01-01
Temporary and permanent shifts in auditory thresholds were found in 43 hard rock musicians and temporary shifts were also observed in some listeners. The threshold shifts involved all of the conventional puretone test frequencies. Custom-fitted polyvinyl chloride ear protectors were found to be effective in prevention of these noise-induced hearing losses. PMID:5008499
Blue-shifted and red-shifted hydrogen bonds: Theoretical study of the CH3CHO· · ·HNO complexes
NASA Astrophysics Data System (ADS)
Yang, Yong; Zhang, Weijun; Gao, Xiaoming
The blue-shifted and red-shifted H-bonds have been studied in complexes CH3CHO?HNO. At the MP2/6-31G(d), MP2/6-31+G(d,p) MP2/6-311++G(d,p), B3LYP/6-31G(d), B3LYP/6-31+G(d,p) and B3LYP/6-311++G(d,p) levels, the geometric structures and vibrational frequencies of complexes CH3CHO?HNO are calculated by both standard and CP-corrected methods, respectively. Complex A exhibits simultaneously red-shifted C bond H?O and blue-shifted N bond H?O H-bonds. Complex B possesses simultaneously two blue-shifted H-bonds: C bond H?O and N bond H?O. From NBO analysis, it becomes evident that the red-shifted C bond H?O H-bond can be explained on the basis of the two opposite effects: hyperconjugation and rehybridization. The blue-shifted C bond H?O H-bond is a result of conjunct C bond H bond strengthening effects of the hyperconjugation and the rehybridization due to existence of the significant electron density redistribution effect. For the blue-shifted N bond H?O H-bonds, the hyperconjugation is inhibited due to existence of the electron density redistribution effect. The large blue shift of the N bond H stretching frequency is observed because the rehybridization dominates the hyperconjugation.
Scaling of echolocation call parameters in bats.
Jones, G
1999-12-01
I investigated the scaling of echolocation call parameters (frequency, duration and repetition rate) in bats in a functional context. Low-duty-cycle bats operate with search phase cycles of usually less than 20 %. They process echoes in the time domain and are therefore intolerant of pulse-echo overlap. High-duty-cycle (>30 %) species use Doppler shift compensation, and they separate pulse and echo in the frequency domain. Call frequency scales negatively with body mass in at least five bat families. Pulse duration scales positively with mass in low-duty-cycle quasi-constant-frequency (QCF) species because the large aerial-hawking species that emit these signals fly fast in open habitats. They therefore detect distant targets and experience pulse-echo overlap later than do smaller bats. Pulse duration also scales positively with mass in the Hipposideridae, which show at least partial Doppler shift compensation. Pulse repetition rate corresponds closely with wingbeat frequency in QCF bat species that fly relatively slowly. Larger, fast-flying species often skip pulses when detecting distant targets. There is probably a trade-off between call intensity and repetition rate because 'whispering' bats (and hipposiderids) produce several calls per predicted wingbeat and because batches of calls are emitted per wingbeat during terminal buzzes. Severe atmospheric attenuation at high frequencies limits the range of high-frequency calls. Low-duty-cycle bats that call at high frequencies must therefore use short pulses to avoid pulse-echo overlap. Rhinolophids escape this constraint by Doppler shift compensation and, importantly, can exploit advantages associated with the emission of both high-frequency and long-duration calls. Low frequencies are unsuited for the detection of small prey, and low repetition rates may limit prey detection rates. Echolocation parameters may therefore constrain maximum body size in aerial-hawking bats.
Zorn, Reiner; Yin, Huajie; Lohstroh, Wiebke; Harrison, Wayne; Budd, Peter M; Pauw, Brian R; Böhning, Martin; Schönhals, Andreas
2018-01-17
Polymers with intrinsic microporosity are promising candidates for the active separation layer in gas separation membranes. Here, the vibrational density of states (VDOS) for PIM-1, the prototypical polymer with intrinsic microporosity, is investigated by means of inelastic neutron scattering. The results are compared to data measured for a more conventional high-performance polyimide used in gas separation membranes (Matrimid). The measured data show the characteristic low frequency excess contribution to VDOS above the Debye sound wave level, generally known as the Boson peak in glass-forming materials. In comparison to the Boson peak of Matrimid, that of PIM-1 is shifted to lower frequencies. This shift is discussed considering the microporous, sponge-like structure of PIM-1 as providing a higher compressibility at the molecular scale than for conventional polymers. For an annealed PIM-1 sample, the Boson peak shifts to higher frequencies in comparison to the un-annealed sample. These changes in the VDOS of the annealed PIM-1 sample are related to changes in the microporous structure as confirmed by X-ray scattering.
Coupled Riccati equations for complex plane constraint
NASA Technical Reports Server (NTRS)
Strong, Kristin M.; Sesak, John R.
1991-01-01
A new Linear Quadratic Gaussian design method is presented which provides prescribed imaginary axis pole placement for optimal control and estimation systems. This procedure contributes another degree of design freedom to flexible spacecraft control. Current design methods which interject modal damping into the system tend to have little affect on modal frequencies, i.e., they predictably shift open plant poles horizontally in the complex plane to form the closed loop controller or estimator pole constellation, but make little provision for vertical (imaginary axis) pole shifts. Imaginary axis shifts which reduce the closed loop model frequencies (the bandwidths) are desirable since they reduce the sensitivity of the system to noise disturbances. The new method drives the closed loop modal frequencies to predictable (specified) levels, frequencies as low as zero rad/sec (real axis pole placement) can be achieved. The design procedure works through rotational and translational destabilizations of the plant, and a coupling of two independently solved algebraic Riccati equations through a structured state weighting matrix. Two new concepts, gain transference and Q equivalency, are introduced and their use shown.
Chung, Min-Huey; Kuo, Terry B J; Hsu, Nanly; Chu, Hsin; Chou, Kuei-Ru; Yang, Cheryl C H
2009-05-01
Disturbed sleep is the most common problem among the many health-related effects of shift work, with shift workers clearly having higher rates of cardiac disorders. However, the possible mechanism underlying the related health effects of shift work has yet to be examined. Consequently, this study aimed to explore the influence of long-term night shift work on the sleep patterns of nurses and their cardiac autonomic nervous system during sleep. Our sample comprised ten permanent night shift and ten regular morning shift nurses. Nurses slept in their dormitory where they were allowed to sleep and wake spontaneously. All sleep parameters were digitized using an ambulatory polysomnographic recorder. Using sleep patterns and heart rate variability, the day- and nighttime sleep of permanent night shift nurses were compared with the nighttime sleep of regular morning shift nurses. Compared with the nighttime sleep of regular morning shift nurses, the pattern of daytime sleep of permanent night shift nurses showed significantly lower sleep onset latency. Permanent night shift nurses' daytime sleep also had greater proportions of Stage 3 and 4 (deep sleep), and arousal index than recorded during their nighttime sleep. Both the low frequency and low to high frequency ratio of the nighttime sleep of night shift nurses were significantly higher during periods of non-rapid eye movement (NREM) sleep than the nighttime sleep of morning shift workers. In addition, the electroencephalography delta-power of the nighttime sleep of night shift nurses was significantly lower during the first NREM episode sleep than those of both the daytime sleep of night shift workers and the nighttime sleep of morning shift nurses. Permanent night shift nurses have higher sympathetic activity during nighttime sleep than regular morning shift nurses. Night shift working may have effects on the sleeping patterns of nurses in the long run, inducing higher cardiac sympathetic regulation.
Total and cause-specific mortality of U.S. nurses working rotating night shifts.
Gu, Fangyi; Han, Jiali; Laden, Francine; Pan, An; Caporaso, Neil E; Stampfer, Meir J; Kawachi, Ichiro; Rexrode, Kathryn M; Willett, Walter C; Hankinson, Susan E; Speizer, Frank E; Schernhammer, Eva S
2015-03-01
Rotating night shift work imposes circadian strain and is linked to the risk of several chronic diseases. To examine associations between rotating night shift work and all-cause; cardiovascular disease (CVD); and cancer mortality in a prospective cohort study of 74,862 registered U.S. nurses from the Nurses' Health Study. Lifetime rotating night shift work (defined as ≥3 nights/month) information was collected in 1988. During 22 years (1988-2010) of follow-up, 14,181 deaths were documented, including 3,062 CVD and 5,413 cancer deaths. Cox proportional hazards models estimated multivariable-adjusted hazard ratios (HRs) and 95% CIs. All-cause and CVD mortality were significantly increased among women with ≥5 years of rotating night shift work, compared to women who never worked night shifts. Specifically, for women with 6-14 and ≥15 years of rotating night shift work, the HRs were 1.11 (95% CI=1.06, 1.17) and 1.11 (95% CI=1.05, 1.18) for all-cause mortality and 1.19 (95% CI=1.07, 1.33) and 1.23 (95% CI=1.09, 1.38) for CVD mortality. There was no significant association between rotating night shift work and all-cancer mortality (HR≥15years=1.08, 95% CI=0.98, 1.19) or mortality of any individual cancer, with the exception of lung cancer (HR≥15years=1.25, 95% CI=1.04, 1.51). Women working rotating night shifts for ≥5 years have a modest increase in all-cause and CVD mortality; those working ≥15 years of rotating night shift work have a modest increase in lung cancer mortality. These results add to prior evidence of a potentially detrimental effect of rotating night shift work on health and longevity. Copyright © 2015 American Journal of Preventive Medicine. All rights reserved.
Total and Cause-Specific Mortality of U.S. Nurses Working Rotating Night Shifts
Gu, Fangyi; Han, Jiali; Laden, Francine; Pan, An; Caporaso, Neil E.; Stampfer, Meir J.; Kawachi, Ichiro; Rexrode, Kathryn M.; Willett, Walter C.; Hankinson, Susan E.; Speizer, Frank; Schernhammer, Eva S.
2014-01-01
Background Rotating night shift work imposes circadian strain and is linked to the risk of several chronic diseases. Purpose To examine associations between rotating night shift work and all-cause, cardiovascular disease (CVD), and cancer mortality in a prospective cohort study of 74,862 registered U.S. nurses from the Nurses’ Health Study. Methods Lifetime rotating night shift work (defined as ≥3 nights/month) information was collected in 1988. During 22 years (1988–2010) of follow-up, 14,181 deaths were documented, including 3,062 CVD and 5,413 cancer deaths. Cox proportional hazards models (2013) estimated multivariable-adjusted hazard ratios (HRs) and 95% CIs. Results All-cause and CVD mortality were significantly increased among women with ≥5 years of rotating night shift work, compared to women who never worked night shifts. Specifically, for women with 6–14 and ≥15 years of rotating night shift work, the HRs were 1.11 (95% CI=1.06, 1.17) and 1.11 (95% CI=1.05, 1.18) for all-cause mortality and 1.19 (95% CI=1.07, 1.33) and 1.23 (95% CI=1.09, 1.38) for CVD mortality. There was no association between rotating night shift work and all-cancer mortality (HR≥15years=1.08, 95% CI=0.89, 1.19) or any other cancer, with the exception of lung cancer (HR≥15years=1.25, 95% CI=1.04, 1.51). Conclusions Women working rotating night shifts for ≥5 five years have a modest increase in all-cause and CVD mortality; those working ≥15 years of rotating night shift work have a modest increase in lung cancer mortality. These results add to prior evidence of a potentially detrimental effect of rotating night shift work on health and longevity. PMID:25576495
The Brainstem Switch for Gaze Shifts in Humans
2001-10-25
Page 1 of 4 THE BRAINSTEM SWITCH FOR GAZE SHIFTS IN HUMANS A. N. Kumar1, R. J. Leigh1,2, S. Ramat3 Department of 1Biomedical Engineering, Case...omnipause neurons during gaze shifts. Using the scleral search coil technique, eye movements were measured in seven normal subjects, as they made...voluntary, disjunctive gaze shifts comprising saccades and vergence movements. Conjugate oscillations of small amplitude and high frequency were identified
Latitudinal shifts of introduced species: possible causes and implications
Qinfeng Guo; Dov F. Sax; Hong Qian; Regan Early
2012-01-01
This study aims to document shifts in the latitudinal distributions of non-native species relative to their own native distributions and to discuss possible causes and implications of these shifts. We used published and newly compiled data on intercontinentally introduced birds, mammals and plants. We found strong correlations between the latitudinal distributions...
Shirota, Hideaki; Kakinuma, Shohei
2015-07-30
In this study, the temperature dependence of the low-frequency spectra of liquid bis(trifluoromethylsulfonyl)amide salts of the monocations 1-methyl-3-propylimidazolium and 1-hexyl-3-methylimidazolium and the dications 1,6-bis(3-methylimidazolium-1-yl)hexane and 1,12-bis(3-methylimidazolium-1-yl)dodecane has been investigated by means of femtosecond optical heterodyne-detected Raman-induced Kerr effect spectroscopy. The intensity in the low-frequency region below 20 cm(-1) in the spectra of the four ionic liquids increases with rising temperature. From a line-shape analysis of the broadened low-frequency spectra of the ionic liquids, it is clear that the lowest-frequency component, which peaks at approximately 5 cm(-1), contributes to the temperature dependence of the spectra. This implies that the activity of the intermolecular translational vibrational motion is increasing with rising temperature. It is also possible that decoupling in the crossover process between intermolecular vibrational motion and structural relaxation occurs as a result of a deterioration of the non-Markovian feature or the loss of memory caused by the higher temperature. The peak of the highest-frequency component, which is due mainly to the imidazolium ring libration, shifts to lower frequency with increasing temperature. This is attributed to weaker interactions of the ionic liquids at higher temperatures. Temperature-dependent viscosities from 293 to 353 K of the four ionic liquids have also been characterized.
A Unified Theory for the Blue- and Red-Shifting Phenomena in Hydrogen and Halogen Bonds.
Wang, Changwei; Danovich, David; Shaik, Sason; Mo, Yirong
2017-04-11
Typical hydrogen and halogen bonds exhibit red-shifts of their vibrational frequencies upon the formation of hydrogen and halogen bonding complexes (denoted as D···Y-A, Y = H and X). The finding of blue-shifts in certain complexes is of significant interest, which has led to numerous studies of the origins of the phenomenon. Because charge transfer mixing (i.e., hyperconjugation in bonding systems) has been regarded as one of the key forces, it would be illuminating to compare the structures and vibrational frequencies in bonding complexes with the charge transfer effect "turned on" and "turned off". Turning off the charge transfer mixing can be achieved by employing the block-localized wave function (BLW) method, which is an ab initio valence bond (VB) method. Further, with the BLW method, the overall stability gained in the formation of a complex can be analyzed in terms of a few physically meaningful terms. Thus, the BLW method provides a unified and physically lucid way to explore the nature of red- and blue-shifting phenomena in both hydrogen and halogen bonding complexes. In this study, a direct correlation between the total stability and the variation of the Y-A bond length is established based on our BLW computations, and the consistent roles of all energy components are clarified. The n(D) → σ*(Y-A) electron transfer stretches the Y-A bond, while the polarization due to the approach of interacting moieties reduces the HOMO-LUMO gap and results in a stronger orbital mixing within the YA monomer. As a consequence, both the charge transfer and polarization stabilize bonding systems with the Y-A bond stretched and red-shift the vibrational frequency of the Y-A bond. Notably, the energy of the frozen wave function is the only energy component which prefers the shrinking of the Y-A bond and thus is responsible for the associated blue-shifting. The total variations of the Y-A bond length and the corresponding stretching vibrational frequency are thus determined by the competition between the frozen-energy term and the sum of polarization and charge transfer energy terms. Because the frozen energy is composed of electrostatic and Pauli exchange interactions and frequency shifting is a long-range phenomenon, we conclude that long-range electrostatic interaction is the driving force behind the frozen energy term.
Strength of German accent under altered auditory feedback
HOWELL, PETER; DWORZYNSKI, KATHARINA
2007-01-01
Borden’s (1979, 1980) hypothesis that speakers with vulnerable speech systems rely more heavily on feedback monitoring than do speakers with less vulnerable systems was investigated. The second language (L2) of a speaker is vulnerable, in comparison with the native language, so alteration to feedback should have a detrimental effect on it, according to this hypothesis. Here, we specifically examined whether altered auditory feedback has an effect on accent strength when speakers speak L2. There were three stages in the experiment. First, 6 German speakers who were fluent in English (their L2) were recorded under six conditions—normal listening, amplified voice level, voice shifted in frequency, delayed auditory feedback, and slowed and accelerated speech rate conditions. Second, judges were trained to rate accent strength. Training was assessed by whether it was successful in separating German speakers speaking English from native English speakers, also speaking English. In the final stage, the judges ranked recordings of each speaker from the first stage as to increasing strength of German accent. The results show that accents were more pronounced under frequency-shifted and delayed auditory feedback conditions than under normal or amplified feedback conditions. Control tests were done to ensure that listeners were judging accent, rather than fluency changes caused by altered auditory feedback. The findings are discussed in terms of Borden’s hypothesis and other accounts about why altered auditory feedback disrupts speech control. PMID:11414137
Effect of extremely low frequency electromagnetic fields on bacterial membrane.
Oncul, Sule; Cuce, Esra M; Aksu, Burak; Inhan Garip, Ayse
2016-01-01
The effect of extremely low frequency electromagnetic fields (ELF-EMF) on bacteria has attracted attention due to its potential for beneficial uses. This research aimed to determine the effect of ELF-EMF on bacterial membrane namely the membrane potential, surface potential, hydrophobicity, respiratory activity and growth. Gram-positive Staphylococcus aureus and Gram-negative Escherichia coli were subjected to ELF-EMF, 50 Hz, 1 mT for 2 h. Membrane potential was determined by fluorescence spectroscopy with or without EDTA (Ethylenediaminetetraacetic acid) with DisC3(5) (3,3-dipropylthiacarbocyanine iodide), zeta potential measurements were performed by electrophoretic mobility, hydrophobicity of the membrane was measured with MATH (Microbial Adhesion to Hydrocarbons) test, respiratory activity was determined with CTC (5-Cyano-2,3-ditolyl tetrazolium chloride), colony forming unit (CFU) and DAPI (4',6-diamidino-2-phenylindole, dihydrochloride) was used for growth determinations. ELF-EMF caused changes in physicochemical properties of both Gram-positive and Gram-negative bacteria. Hyperpolarization was seen in S. aureus and EDTA-treated E. coli. Surface potential showed a positive shift in S. aureus contrariwise to the negative shift seen in EDTA-untreated E. coli. Respiratory activity increased in both bacteria. A slight decrease in growth was observed. These results show that ELF-EMF affects the crucial physicochemical processes in both Gram-positive and Gram-negative bacteria which need further research.
NASA Astrophysics Data System (ADS)
Xu, Wenrui; Lai, Dong
2017-10-01
In coalescing neutron star (NS) binaries, tidal force can resonantly excite low-frequency (≲500 Hz ) oscillation modes in the NS, transferring energy between the orbit and the NS. This resonant tide can induce phase shift in the gravitational waveforms, and potentially provide a new window of studying NS interior using gravitational waves. Previous works have considered tidal excitations of pure g-modes (due to stable stratification of the star) and pure inertial modes (due to Coriolis force), with the rotational effect treated in an approximate manner. However, for realistic NSs, the buoyancy and rotational effects can be comparable, giving rise to mixed inertial-gravity modes. We develop a nonperturbative numerical spectral code to compute the frequencies and tidal coupling coefficients of these modes. We then calculate the phase shift in the gravitational waveform due to each resonance during binary inspiral. Given the uncertainties in the NS equation of state and stratification property, we adopt polytropic NS models with a parametrized stratification. We derive relevant scaling relations and survey how the phase shift depends on various properties of the NS. We find that for canonical NSs (with mass M =1.4 M⊙ and radius R =10 km ) and modest rotation rates (≲300 Hz ), the gravitational wave phase shift due to a resonance is generally less than 0.01 radian. But the phase shift is a strong function of R and M , and can reach a radian or more for low-mass NSs with larger radii (R ≳15 km ). Significant phase shift can also be produced when the combination of stratification and rotation gives rise to a very low frequency (≲20 Hz in the inertial frame) modified g-mode. As a by-product of our precise calculation of oscillation modes in rotating NSs, we find that some inertial modes can be strongly affected by stratification; we also find that the m =1 r -mode, previously identified to have a small but finite inertial-frame frequency based on the Cowling approximation, in fact has essentially zero frequency, and therefore cannot be excited during the inspiral phase of NS binaries.
2014-07-17
frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experimentsa) Ultra-intense laser -matter...interaction experiments (>1018 W/cm2) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the...interferometry technique for probing pre- plasma expansion in ultra-intense laser experimentsa) Report Title Ultra-intense laser -matter interaction
Single exosome detection in serum using microtoroid optical resonators (Conference Presentation)
NASA Astrophysics Data System (ADS)
Su, Judith
2016-03-01
Recently exosomes have attracted interest due to their potential as cancer biomarkers. We report the real time, label-free sensing of single exosomes in serum using microtoroid optical resonators. We use this approach to assay the progression of tumors implanted in mice by specifically detecting low concentrations of tumor-derived exosomes. Our approach measures the adsorption of individual exosomes onto a functionalized silica microtoroid by tracking changes in the optical resonant frequency of the microtoroid. When exosomes land on the microtoroid, they perturb its refractive index in the evanescent field and thus shift its resonance frequency. Through digital frequency locking, we are able to rapidly track these shifts with accuracies of better than 10 attometers (one part in 10^11). Samples taken from tumor-implanted mice from later weeks generated larger frequency shifts than those from earlier weeks. Control samples taken from a mouse with no tumor generated no such increase in signal between subsequent weeks. Analysis of shifts from tumor-implanted mouse samples show a distribution of unitary steps, with the maximum step having a height of ~1.2 fm, corresponding to an exosome size of 44 ± 4.8 nm. This size range corresponds to that found by performing nanoparticle tracking analysis on the same samples. Our results demonstrate development towards a minimally-invasive tumor "biopsy" that eliminates the need to find and access a tumor.
Josan, Sonal; Hurd, Ralph; Park, Jae Mo; Yen, Yi-Fen; Watkins, Ron; Pfefferbaum, Adolf; Spielman, Daniel; Mayer, Dirk
2014-06-01
In contrast to [1-(13) C]pyruvate, hyperpolarized [2-(13) C]pyruvate permits the ability to follow the (13) C label beyond flux through pyruvate dehydrogenase complex and investigate the incorporation of acetyl-coenzyme A into different metabolic pathways. However, chemical shift imaging (CSI) with [2-(13) C]pyruvate is challenging owing to the large spectral dispersion of the resonances, which also leads to severe chemical shift displacement artifacts for slice-selective acquisitions. This study introduces a sequence for three-dimensional CSI of [2-(13) C]pyruvate using spectrally selective excitation of limited frequency bands containing a subset of metabolites. Dynamic CSI data were acquired alternately from multiple frequency bands in phantoms for sequence testing and in vivo in rat heart. Phantom experiments verified the radiofrequency pulse design and demonstrated that the signal behavior of each group of resonances was unaffected by excitation of the other frequency bands. Dynamic three-dimensional (13) C CSI data demonstrated the sequence capability to image pyruvate, lactate, acetylcarnitine, glutamate, and acetoacetate, enabling the analysis of organ-specific spectra and metabolite time courses. The presented method allows CSI of widely separated resonances without chemical shift displacement artifact, acquiring multiple frequency bands alternately to obtain dynamic time-course information. This approach enables robust imaging of downstream metabolic products of acetyl-coenzyme A with hyperpolarized [2-(13) C]pyruvate. Copyright © 2013 Wiley Periodicals, Inc.
Multipoint sensing with a low-coherence source using single-arm frequency-shifted interferometry
Zhang, Yiwei; Ye, Fei; Qi, Bing; ...
2016-07-12
We demonstrate that multiple-site sensing along an optical fiber can be done with incoherent continuous-wave light. Here, using a broadband low-coherence noise source, a slow detector, and an optical modulator, we construct a single-arm frequency-shifted interferometer (SA-FSI) capable of simultaneously sensing multiple weak-reflection sites distributed either in parallel or in series along fiber links. By scanning the driving frequency of an electro-optic amplitude modulator in the range of 2.7–3.2 GHz at steps of 41.7 KHz, we demonstrate a spatial resolution of 0.3 m and a measurement range of over 1 km.
A report on the gravitational redshift test for non-metric theories of gravitation
NASA Technical Reports Server (NTRS)
1980-01-01
The frequencies of two atomic hydrogen masers and of three superconducting cavity stabilized oscillators were compared as the ensemble of oscillators was moved in the Sun's gravitational field by the rotation and orbital motion of the Earth. Metric gravitation theories predict that the gravitational redshifts of the two types of oscillators are identical, and that there should be no relative frequency shift between the oscillators; nonmetric theories, in contrast, predict a frequency shift between masers and SCSOs that is proportional to the change in solar gravitational potential experienced by the oscillators. The results are consistent with metric theories of gravitation at a level of 2%.
NASA Astrophysics Data System (ADS)
Grilli, S. T.; Guérin, C. A.; Grosdidier, S.
2014-12-01
Where coastal tsunami hazard is governed by near-field sources, Submarine Mass Failures (SMFs) or earthquakes, tsunami propagation times may be too small for a detection based on deep or shallow water buoys. To offer sufficient warning time, it has been proposed by others to implement early warning systems relying on High Frequency Radar (HFR) remote sensing, that has a dense spatial coverage far offshore. A new HFR, referred to as STRADIVARIUS, is being deployed by Diginext Inc. (in Fall 2014), to cover the "Golfe du Lion" (GDL) in the Western Mediterranean Sea. This radar uses a proprietary phase coding technology that allows detection up to 300 km, in a bistatic configuration (for which radar and antennas are separated by about 100 km). Although the primary purpose of the radar is vessel detection in relation to homeland security, the 4.5 MHz HFR will provide a strong backscattered signal for ocean surface waves at the so-called Bragg frequency (here, wavelength of 30 m). The current caused by an arriving tsunami will shift the Bragg frequency, by a value proportional to the current magnitude (projected on the local radar ray direction), which can be easily obtained from the Doppler spectrum of the HFR signal. Using state of the art tsunami generation and propagation models, we modeled tsunami case studies in the western Mediterranean basin (both seismic and SMFs) and simulated the HFR backscattered signal that would be detected for the entire GDL and beyond. Based on simulated HFR signal, we developed two types of tsunami detection algorithms: (i) one based on standard Doppler spectra, for which we found that to be detectable within the environmental and background current noises, the Doppler shift requires tsunami currents to be at least 10-15 cm/s, which typically only occurs on the continental shelf in fairly shallow water; (ii) to allow earlier detection, a second algorithm computes correlations of the HFR signals at two distant locations, shifted in time by the tsunami propagation time between these locations (easily computed based on bathymetry). We found that this second method allowed detection for currents as low as 5 cm/s, i.e., in deeper water, beyond the shelf and further away from the coast, thus allowing an earlier detection.
Frequency domain phase-shifted confocal microscopy (FDPCM) with array detection
NASA Astrophysics Data System (ADS)
Ge, Baoliang; Huang, Yujia; Fang, Yue; Kuang, Cuifang; Xiu, Peng; Liu, Xu
2017-09-01
We proposed a novel method to reconstruct images taken by array detected confocal microscopy without prior knowledge about its detector distribution. The proposed frequency domain phase-shifted confocal microscopy (FDPCM) shifts the image from each detection channel to its corresponding place by substituting the phase information in Fourier domain. Theoretical analysis shows that our method could approach the resolution nearly twofold of wide-field microscopy. Simulation and experiment results are also shown to verify the applicability and effectiveness of our method. Compared to Airyscan, our method holds the advantage of simplicity and convenience to be applied to array detectors with different structure, which makes FDPCM have great potential in the application of biomedical observation in the future.