Biomonitoring of perfluorinated compounds in a drop of blood.
Mao, Pan; Wang, Daojing
2015-06-02
Biomonitoring of pollutants and their metabolites and derivatives using biofluids provides new opportunities for spatiotemporal assessment of human risks to environmental exposures. Perfluorinated compounds (PFCs) have been used widely in industry and pose significant environmental concerns due to their stability and bioaccumulation in humans and animals. However, current methods for extraction and measurement of PFCs require relatively large volumes (over one hundred microliters) of blood samples, and therefore, are not suitable for frequent blood sampling and longitudinal biomonitoring of PFCs. We have developed a new microassay, enabled by our silicon microfluidic chip platform, for analyzing PFCs in small volumes (less than five microliters) of blood. Our assay integrates on-chip solid-phase extraction (SPE) with online nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nanoLC-ESI-MS) detection. We demonstrated high sample recovery, excellent interday and intraday accuracy and precision, and a limit of detection down to 50 femtogram of PFCs, in one microliter of human plasma. We validated our assay performance using pooled human plasma and NIST SRM 1950 samples. Our microfluidic chip-based assay may enable frequent longitudinal biomonitoring of PFCs and other environmental toxins using a finger prick of blood, thereby providing new insights into their bioaccumulation, bioavailability, and toxicity.
Comparison of three methods of sampling trout blood for measurements of hematocrit
Steucke, Erwin W.; Schoettger, Richard A.
1967-01-01
Trout blood is frequently collected for hematocrit measurements by excising the caudal fin (Snieszko, 1960), but this technique is impractical if valuable fish are to be sampled or if repeated observations are desired. Schiffman (1959) and Snieszko (1960) collected blood from the dorsal aorta and the heart, but these methods are relatively slow and require the preparation of needles and syringes. The use of pointed capillary tubes for cardiac punctures increases the speed of sampling, but body fluids may dilute the blood (Perkins, 1957; Larsen and Snieszko, 1961; and Normandau, 1962). There is need for methods of sampling which are rapid and which neither influence hematological determinations nor harm the fish.
Sucu, Nurgün; Caylan, Rahmet; Aydin, Kemalettin; Yilmaz, Gürdal; Aktoz Boz, Gönülden; Köksal, Iftihar
2005-10-01
In this study, the rate of blood culture contamination, bacterial pathogens and their antimicrobial susceptibilities causing nosocomial and community acquired bloodstream infections were investigated prospectively during the period February 2003 to February 2004. In the study period, among the 5994 blood culture samples obtained from 3114 patients, 1091 (18%) yielded positive results. Seventy-four of them (1.2%) were evaluated as false positive, 514 (9%) were pseudobacteremia or contamination. According to patients' clinical features, 503 (8%) blood culture samples were associated with blood stream infections, and 358 of them (71%) were primary episodes. Twohundred and ninetyfour of primary episodes (82%) were hospital acquired and 64 were community acquired bloodstream infections. Staphylococcus aureus was the most frequently isolated agent in the hospital and community acquired bloodstream infections at the rates of 16% and 20%, respectively. In hospital acquired blood stream infections, Escherichia coil (9%) and Pseudomonas aeruginosa (8%); in community acquired bloodstream infections Streptococcus spp (17%) and E. coli (15%) were the other most frequently isolated bacterial agents. Methicillin resistance of S. aureus isolates was determined as 54% in hospital acquired blood stream infections and 25% in community acquired blood stream infections.
Singh, Gurmeet K S; Turner, Leo; Desai, Reena; Jimenez, Mark; Handelsman, David J
2014-07-01
Testosterone (T) and nandrolone (N) esters require deep im injections by medical personnel but these often deposit injectate into sc fat so that more convenient sc self-administration may be feasible. To investigate the feasibility and pharmacology of sc injection of N decanoate in healthy men using dried blood spot (DBS) for frequent blood sampling without clinic visits. Healthy male volunteers received 100 mg N decanoate by a single sc injection. Finger-prick capillary blood was spotted onto filter paper before injection daily at home for 21 d and stored at room temperature. Venous whole blood was also spotted onto filter paper before and weekly for 3 wk after injection. DBS were extracted for assay of N and T by liquid chromatography tandem mass spectrometry in a single batch with serum concentrations estimated with adjustment for capillary blood sample volume and hematocrit to define peak (N) or nadir (T) time and concentration from individual daily measurements. Daily serum N peaked 2.50 ± 0.25 (SEM) ng/mL at a median (range) of 6 (4-13) days causing a reduction in serum T from 3.50 ± 0.57 ng/mL at baseline to a nadir of 0.38 ± 0.13 (SEM) ng/mL (89 ± 3% suppression) at a median (range) of 8 (5-16) days. Simultaneously sampled capillary, venous whole blood, and serum gave almost identical results for serum T and N. Finger-pricks and sc injections were well tolerated. This study demonstrates that A) DBS sampling with liquid chromatography mass spectrometry steroid analysis achieves frequent time sampling in the community without requiring clinic visits, venesection, or frozen serum storage, and B) androgen esters in an oil vehicle can be delivered effectively by sc injection, thus avoiding the need for medically supervised deep-im injections.
Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka
2015-01-01
Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia. PMID:26524965
Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka
2015-01-01
Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.
Red blood cell transfusion in newborn infants
Whyte, Robin K; Jefferies, Ann L
2014-01-01
Red blood cell transfusion is an important and frequent component of neonatal intensive care. The present position statement addresses the methods and indications for red blood cell transfusion of the newborn, based on a review of the current literature. The most frequent indications for blood transfusion in the newborn are the acute treatment of perinatal hemorrhagic shock and the recurrent correction of anemia of prematurity. Perinatal hemorrhagic shock requires immediate treatment with large quantities of red blood cells; the effects of massive transfusion on other blood components must be considered. Some guidelines are now available from clinical trials investigating transfusion in anemia of prematurity; however, considerable uncertainty remains. There is weak evidence that cognitive impairment may be more severe at follow-up in extremely low birth weight infants transfused at lower hemoglobin thresholds; therefore, these thresholds should be maintained by transfusion therapy. Although the risks of transfusion have declined considerably in recent years, they can be minimized further by carefully restricting neonatal blood sampling. PMID:24855419
Godolphin, W; Cameron, E C; Frohlich, J; Price, J D
1979-02-01
Patients on long-term hemodialysis via arteriovenous fistula received heparin when the fistula needle was inserted, before a sample of blood was obtained for chemical analysis. The resultant release of lipoprotein lipase activity in vivo and continued lipolytic activity in vitro sometimes produced sufficient free fatty acid to precipitate calcium soaps. The consequent spurious hypocalcemia was most frequently observed when the patients had chylomicronemia. This cause of apparent hypocalcemia was eliminated either by immediate analyses of the blood samples or by obtaining samples before systemic heparinization.
Podda, Gian Marco; Pugliano, Mariateresa; Femia, Eti Alessandra; Mezzasoma, Anna Maria; Gresele, Paolo; Carpani, Giovanni; Cattaneo, Marco
2012-07-01
Spuriously low platelet counts (PCs) can be observed in normal blood samples anticoagulated with ethylenediamine tetra-acetic acid (EDTA)and, much less frequently, with citrate-tris-pyridossalphosphate (CPT),due to time-dependent in vitro platelet agglutination. Accuracy in PC determination is essential as PC is one of the parameters that usually guides treatment for thrombocytopenic patients. PCs of 93 thrombocy to penic patients were measured in EDTA- or CPT-anticoagulated blood samples immediately after sampling (t0) and 90 min (t90) after storage at room temperature. The presence of platelet agglutinates in blood samples was determined by examining blood smears using optical microscopy.PCs decreased at t90 with both anticoagulants. Platelet agglutinates were present at t90 in 27% of EDTA-samples vs. 2% of CPT-samples with decreased PCs (P < 0.001). Based on PCs in EDTA-samples, 15 patients (16%) shifted from a lower bleeding risk at t0 to a higher bleeding risk category at t90 (P 5 0.019), compared to 5 (5%) patients, based on PCs in CPT-samples. Therefore, time-dependent in vitro platelet agglutination in EDTA-blood samples may cause underestimation of PCs in thrombocytopenic patients, possibly leading to improper management.
Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types.
Sembiring, Krisnarta; Ramayani, Oke Rina; Lubis, Munar
2018-02-15
Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. To determine the difference in mean blood pressure among adolescents based on dyssomnia types. Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep Disturbance Scale for Children (SDSC) questionnaire. Stature and blood pressure data were collected along with demographic data and sleep disorder questionnaire. Analyses were done with Kruskal-Wallis test and logistic regression. P - value < 0.05 was considered significant. Seventy-six samples were obtained with mean age 13.9 (SD 1.14) years - old. Dyssomnia proportion and hypertension were 72/76 and 20/76 respectively. Mean systolic (SBP) and diastolic blood pressure (DBP) was 111.1 (SD 16.46) mmHg and 70.3 (SD 11.98) mmHg respectively. Mean SDSC score was 49.7 (SD 8.96), and the most frequent dyssomnia type was disorders of initiating and maintaining sleep. Age and sex were not the risk factors of hypertension in dyssomnia. There was a significant difference in mean SBP (P = 0.006) and DBP (P = 0.022) based on dyssomnia types. Combination dyssomnia type had the highest mean blood pressure among dyssomnia types. There is a significant difference in mean blood pressure among adolescents based on dyssomnia types.
Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart
2015-01-01
Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions.
NASA Astrophysics Data System (ADS)
Suzuki, Yusuke; Maruo, Katsuhiko; Zhang, Alice W.; Shimogaki, Kazushige; Ogawa, Hideto; Hirayama, Fumiya
2012-01-01
Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components. Hence this study is aimed to serve as a preliminary study for the nondestructive measurement of glucose level in transfusion blood. The glucose concentrations in red blood cell (RBC) samples were predicted using near-infrared diffuse-reflectance spectroscopy in the 1350 to 1850 nm wavelength region. Furthermore, the effects of donor, hematocrit level, and temperature variations among the RBC samples were observed. Results showed that the prediction performance of a dataset which contained samples that differed in all three parameters had a standard error of 29.3 mg/dL. Multiplicative scatter correction (MSC) preprocessing method was also found to be effective in minimizing the variations in scattering patterns created by various sample properties. The results suggest that the diffuse-reflectance spectroscopy may provide another avenue for the detection of bacterial contamination in red cell concentrations (RCC) products.
Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart
2015-01-01
Background Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. Results While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. Conclusion The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions. PMID:26599228
[Prevalence of high blood pressure in children and adolescents from the city of Maceió, Brazil].
Moura, Adriana A; Silva, Maria A M; Ferraz, Maria R M T; Rivera, Ivan R
2004-01-01
To define the prevalence of high blood pressure in a representative sample of children and adolescents from the city of Maceió, state of Alagoas, Brazil, and to investigate the association of high blood pressure with age, sex and nutritional status. This cross-sectional study was carried out from May 2000 to September 2002. Individuals between 7 and 17 years of age were selected among all the 185,702 students from public and private schools. The size of the sample was defined based on the expected prevalence of hypertension for the age group. After randomization, data were collected through a questionnaire. Blood pressure was measured twice. Weight and height were also measured. High blood pressure was defined as systolic and/or diastolic blood pressure over the 95th percentile in one or in both measures. The final sample included 1,253 students (706 females). One hundred and eighteen students had high blood pressure (mean age 13 years; 44% males). Risk of being overweight and excess weight were identified, respectively, in 9.3 and 4.5% of the students. These variables were significantly associated with high blood pressure. The prevalence of high blood pressure was 9.4%. High blood pressure was significantly more frequent among overweight students and among those at risk for being overweight.
Impact of hyperthermal rotary blood pump surfaces on blood clotting behavior: an approach.
Hamilton, Kathrin F; Schlanstein, Peter C; Mager, Ilona; Schmitz-Rode, Thomas; Steinseifer, Ulrich
2009-09-01
The influence of heat dissipating systems, such as rotary blood pumps, was investigated. Titanium cylinders as rotary blood pump housing dummies were immersed in porcine blood and constantly tempered at specific temperatures (37-60 degrees C) over a defined period of time. The porcine blood was anticoagulated either by low heparin dosage or citrate. At frequent intervals, samples were taken for blood analysis and the determination of the plasmatic coagulation cascade. Blood parameters do not alter at surface temperatures below 50 degrees C. Hyperthermia-induced hemolysis could be confirmed. The plasmatic coagulation cascade is terminated at surface temperatures exceeding 55 degrees C. The adhesion of blood constituents on surfaces is temperature and time dependent, and structural changes of adhesions and blood itself were detected.
Bausinger, Julia; Speit, Günter
2016-09-01
The comet assay is frequently used in human biomonitoring for the detection of exposure to genotoxic agents. Peripheral blood samples are most frequently used and tested either as whole blood or after isolation of lymphocytes (i.e. peripheral blood mononuclear cells, PBMC). To investigate a potential impact of lymphocyte isolation on induced DNA damage in human blood samples, we exposed blood ex vivo to mutagens with different modes of genotoxic action. The comet assay was performed either directly with whole blood at the end of the exposure period or with lymphocytes isolated directly after exposure. In addition to the recommended standard protocol for lymphocyte isolation, a shortened protocol was established to optimise the isolation procedure. The results indicate that the effects of induced DNA strand breaks and alkali-labile sites induced by ionising radiation and alkylants, respectively, are significantly reduced in isolated lymphocytes. In contrast, oxidative DNA base damage (induced by potassium bromate) and stable bulky adducts (induced by benzo[a]pyrene-7,8-dihydrodiol-9,10-epoxide; BPDE) seem to be less affected. Our findings suggest that in vivo-induced DNA damage might also be reduced in isolated lymphocytes in comparison with the whole blood depending of the types of DNA damage induced. Because only small genotoxic effects can generally be expected in human biomonitoring studies with the comet assay after occupational and environmental exposure to genotoxic agents, any loss might be relevant and should be avoided. The possibility of such effects and their potential impact on variability of comet assay results in human biomonitoring should be considered when performing or evaluating such kind of studies. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Circulating tumor cells in patients with testicular germ cell tumors.
Nastały, Paulina; Ruf, Christian; Becker, Pascal; Bednarz-Knoll, Natalia; Stoupiec, Małgorzata; Kavsur, Refik; Isbarn, Hendrik; Matthies, Cord; Wagner, Walter; Höppner, Dirk; Fisch, Margit; Bokemeyer, Carsten; Ahyai, Sascha; Honecker, Friedemann; Riethdorf, Sabine; Pantel, Klaus
2014-07-15
Germ cell tumors (GCTs) represent the most frequent malignancies among young men, but little is known about circulating tumor cells (CTCs) in these tumors. Considering their heterogeneity, CTCs were investigated using two independent assays targeting germ cell tumor and epithelial cell-specific markers, and results were correlated with disease stage, histology, and serum tumor markers. CTCs were enriched from peripheral blood (n = 143 patients) and testicular vein blood (TVB, n = 19 patients) using Ficoll density gradient centrifugation. For CTC detection, a combination of germ cell tumor (anti-SALL4, anti-OCT3/4) and epithelial cell-specific (anti-keratin, anti-EpCAM) antibodies was used. In parallel, 122 corresponding peripheral blood samples were analyzed using the CellSearch system. In total, CTCs were detected in 25 of 143 (17.5%) peripheral blood samples, whereas only 11.5% of patients were CTC-positive when considering exclusively the CellSearch assay. The presence of CTCs in peripheral blood correlated with clinical stage (P < 0.001) with 41% of CTC positivity in patients with metastasized tumors and 100% in patients with relapsed and chemotherapy-refractory disease. Histologically, CTC-positive patients suffered more frequently from nonseminomatous primary tumors (P < 0.001), with higher percentage of yolk sac (P < 0.001) and teratoma (P = 0.004) components. Furthermore, CTC detection was associated with elevated serum levels of α-fetoprotein (AFP; P = 0.025), β-human chorionic gonadotropin (βHCG; P = 0.002), and lactate dehydrogenase (LDH; P = 0.002). Incidence and numbers of CTCs in TVB were much higher than in peripheral blood. The inclusion of germ cell tumor-specific markers improves CTC detection in GCTs. CTCs occur frequently in patients with more aggressive disease, and there is a gradient of CTCs with decreasing numbers from the tumor-draining vein to the periphery. ©2014 American Association for Cancer Research.
Cordón, G Pérez; Prados, A Hitos; Romero, D; Moreno, M Sánchez; Pontes, A; Osuna, A; Rosales, M J
2009-11-12
Birds from the Almuñecar ornithological garden (Granada, Spain) were surveyed from June 2006 to May 2007 to establish programmes to prevent, control, and treat intestinal and haematic parasites. A total of 984 faecal samples and 41 samples of blood were collected from Psittacidae, Cacatuidae, Phasianidae, and Anatidae. One or more intestinal parasites were identified in 51.6% of the samples. Blood parasites were found in 26.8% of the birds examined. The most frequent pathogenic endoparasites were coccidians, such as Cyclospora sp. (4.5%), Eimeria sp. (4.1%) and Isospora sp. (2%) and helminths such as Capillaria sp. (10. 1%), Ascaridia sp. (4.9%) and Heterakis gallinarum (4.9%). All the parasites varied with season but the most were found year round. Multiple parasitic infections by intestinal parasites were common, with 196 of 984 faecal samples having 2-5 intestinal parasites. The most frequent cases of multiple parasitism were Blastocystis plus Entamoeba sp. and Blastocystis plus Cyclospora sp. The haematic protozoa detected were Haemoproteus sp. (17%) and Plasmodium sp. (7.3%). Multiple parasitism by Haemoproteus sp. and Plasmodium sp. was detected in 1 sample of Gallus gallus. After each sampling, some of the affected animals were treated according to our results, and the corresponding programmes of prevention and control were designed.
BECon: a tool for interpreting DNA methylation findings from blood in the context of brain.
Edgar, R D; Jones, M J; Meaney, M J; Turecki, G; Kobor, M S
2017-08-01
Tissue differences are one of the largest contributors to variability in the human DNA methylome. Despite the tissue-specific nature of DNA methylation, the inaccessibility of human brain samples necessitates the frequent use of surrogate tissues such as blood, in studies of associations between DNA methylation and brain function and health. Results from studies of surrogate tissues in humans are difficult to interpret in this context, as the connection between blood-brain DNA methylation is tenuous and not well-documented. Here, we aimed to provide a resource to the community to aid interpretation of blood-based DNA methylation results in the context of brain tissue. We used paired samples from 16 individuals from three brain regions and whole blood, run on the Illumina 450 K Human Methylation Array to quantify the concordance of DNA methylation between tissues. From these data, we have made available metrics on: the variability of cytosine-phosphate-guanine dinucleotides (CpGs) in our blood and brain samples, the concordance of CpGs between blood and brain, and estimations of how strongly a CpG is affected by cell composition in both blood and brain through the web application BECon (Blood-Brain Epigenetic Concordance; https://redgar598.shinyapps.io/BECon/). We anticipate that BECon will enable biological interpretation of blood-based human DNA methylation results, in the context of brain.
Schwarzer, Patrik; Kuhn, Sven-Olaf; Stracke, Sylvia; Gründling, Matthias; Knigge, Stephan; Selleng, Sixten; Helm, Maximilian; Friesecke, Sigrun; Abel, Peter; Kallner, Anders; Nauck, Matthias; Petersmann, Astrid
2015-09-08
Ionized calcium (iCa) concentration is often used in critical care and measured using blood gas analyzers at the point of care. Controlling and adjusting regional citrate anticoagulation (RCA) for continuous renal replacement therapy (CRRT) involves measuring the iCa concentration in two samples: systemic with physiological iCa concentrations and post filter samples with very low iCa concentrations. However, modern blood gas analyzers are optimized for physiological iCa concentrations which might make them less suitable for measuring low iCa in blood with a high concentration of citrate. We present results of iCa measurements from six different blood gas analyzers and the impact on clinical decisions based on the recommendations of the dialysis' device manufacturer. The iCa concentrations of systemic and post filter samples were measured using six distinct, frequently used blood gas analyzers. We obtained iCa results of 74 systemic and 84 post filter samples from patients undergoing RCA for CRRT at the University Medicine of Greifswald. The systemic samples showed concordant results on all analyzers with median iCa concentrations ranging from 1.07 to 1.16 mmol/L. The medians of iCa concentrations for post filter samples ranged from 0.21 to 0.50 mmol/L. Results of >70% of the post filter samples would lead to major differences in decisions regarding citrate flow depending on the instrument used. Measurements of iCa in post filter samples may give misleading information in monitoring the RCA. Recommendations of the dialysis manufacturer need to be revised. Meanwhile, little weight should be given to post filter iCa. Reference methods for low iCa in whole blood containing citrate should be established.
Attitudes of NICU professionals regarding feeding blood-tinged colostrum or milk.
Phelps, M M; Bedard, W S; Henry, E; Christensen, S S; Gardner, R W; Karp, T; Wiedmeier, S E; Christensen, R D
2009-02-01
Mothers of neonatal intensive care unit (NICU) patients sometimes bring expressed milk that is blood tinged to the NICU. In certain instances, the blood contamination appears minimal, whereas in others, the milk is quite dark pink. We have observed inconsistencies in practice regarding whether or not to feed blood-tinged colostrum or milk to NICU patients. We know of no evidence that establishes best practice in this area, and thus we sought to determine attitudes of NICU professionals on which to base a potentially best practice. We conducted a web-based anonymous survey of attitudes of NICU professionals at Intermountain Healthcare regarding feeding blood-tinged expressed milk to NICU patients. These professionals included neonatologists, neonatal nurse practitioners, NICU nurses, NICU dieticians and lactation consultants. Survey results were returned from 64% (426 of 667) of those to whom it was sent. A total of 75% of respondents reported that their practice was NOT to feed the blood-tinged milk illustrated in the figure as sample 2, and nearly all respondents (98%) reported that they would NOT feed the milk illustrated as sample 3. The majority of the neonatologists (56%) and the lactation consultants (58%) recommended feeding moderately bloody milk (sample 2), whereas only 22% of the neonatal nurse practitioners (NNPs), NICU nurses and NICU dieticians recommended feeding such samples (<0.001). The most frequently selected reason for NOT feeding blood-tinged milk was that it would likely cause gastrointestinal upset and feeding intolerance (selected by 77%). The majority (87%) overestimated the amount of blood contaminating a milk sample (sample 3). As colostrum and human milk feedings can be of value to NICU patients, evidence should be assembled to document whether feeding blood-tinged samples indeed have the problems listed by the survey respondents. Such evidence is needed to enable informed decisions involving the benefits vs risks of feeding blood-tinged expressed milk to NICU patients.
Frequency of ABO/Rhesus Blood Groups in Patients with Diabetes Mellitus.
Oner, Can; Dogan, Burcu; Telatar, Berrin; Celik Yagan, Canan Fidan; Oguz, Aytekin
2016-01-01
The correlation between ABO/Rh blood groups and diabetes mellitus is still controversial. The aim of this study was to determine the relationship between ABO/Rhesus blood groups and diabetes in Turkish population. This cross-sectional study was conducted in Istanbul Medeniyet University Göztepe Education and Training Hospital's Diabetes Units. The study group was composed of 421 patients with type-1 diabetes, 484 patients with type-2 diabetes and 432 controls. Blood samples were collected and tested for ABO/Rhesus blood groups. Data was analyzed by SPSS version 17.0. A significant association was found between blood groups and diabetes mellitus. The frequency of AB blood group was significantly higher in type-1 diabetics; and A blood group was significantly higher in type-2 diabetics. Furthermore, Rh negativity were significantly more frequent in type-2 diabetics.
Seth, Mayank; Jackson, Karen V.; Winzelberg, Sarah; Giger, Urs
2012-01-01
Objective To compare accuracy and ease of use of a card agglutination assay, an immunochromatographic cartridge method, and a gel-based method for canine blood typing. Sample Blood samples from 52 healthy blood donor dogs, 10 dogs with immune-mediated hemolytic anemia (IMHA), and 29 dogs with other diseases. Procedures Blood samples were tested in accordance with manufacturer guidelines. Samples with low PCVs were created by the addition of autologous plasma to separately assess the effects of anemia on test results. Results Compared with a composite reference standard of agreement between 2 methods, the gel-based method was found to be 100% accurate. The card agglutination assay was 89% to 91% accurate, depending on test interpretation, and the immunochromatographic cartridge method was 93% accurate but 100% specific. Errors were observed more frequently in samples from diseased dogs, particularly those with IMHA. In the presence of persistent autoagglutination, dog erythrocyte antigen (DEA) 1.1 typing was not possible, except with the immunochromatographic cartridge method. Conclusions and Clinical Relevance The card agglutination assay and immunochromatographic cartridge method, performed by trained personnel, were suitable for in-clinic emergency DEA 1.1 blood typing. There may be errors, particularly for samples from dogs with IMHA, and the immunochromatographic cartridge method may have an advantage of allowing typing of samples with persistent autoagglutination. The laboratory gel-based method would be preferred for routine DEA 1.1 typing of donors and patients if it is available and time permits. Current DEA 1.1 typing techniques appear to be appropriately standardized and easy to use. PMID:22280380
Correa, Loreto; Zapata, Beatriz; Soto-Gamboa, Mauricio
2012-01-01
The breeding of wild animals for commercial purposes is becoming more frequent nowadays. This situation has led to an increase in contact rates between wild and domestic animals, with subsequent reciprocal transmission of parasites. In this study, we characterized the gastrointestinal and blood parasites of a group of 15 semi-captive guanacos (Lama guanicoe). We characterized gastrointestinal parasites by analyzing fecal samples through the sedimentation-flotation technique and hemoparasites by using blood smears stained with Giemsa. We found several gastrointestinal parasites including Nematoda and protozoans. The most frequently found parasites were Nematodirus sp. and Eimeria sp. In contrast with previous studies, neither Cestoda nor Fasciola were found. The only hemoparasite detected was Mycoplasma haemolamae, a parasite already described in llamas and alpacas. We conclude that the most frequent gastrointestinal parasites of semi-captive guanacos were nematodes and protozoans. Also, the hemoparasite M. haemolamae seems to be prevalent among captive populations of South American camelids. Finally, captive guanacos share several parasites with the traditional livestock. Therefore, keeping captive or semi-captive guanacos without an adequate sanitary protocol might have adverse consequences to adjacent traditional cattle farming and/or for wild animals.
Periodontopathic microorganisms in peripheric blood after scaling and root planing.
Lafaurie, Gloria Inés; Mayorga-Fayad, Isabel; Torres, María Fernanda; Castillo, Diana Marcela; Aya, Maria Rosario; Barón, Alexandra; Hurtado, Paola Andrea
2007-10-01
The objective of this study was to evaluate the frequency of periodontopathic and other subgingival anaerobic and facultative bacteria in the bloodstream following scaling and root planing (SRP). Forty-two patients with severe generalized chronic periodontitis (GChP) and generalized aggressive periodontitis (GAgP) were included in the study. Four samples of peripheric blood were drawn from the cubital vein at different times: Pre-treatment: immediately before the SRP procedure (T1), immediately after treatment (T2), 15 min. post-treatment (T3) and 30 min. post-treatment (T4). In order to identify the presence of microorganisms in blood, subcultures were conducted under anaerobic conditions. 80.9% of the patients presented positive cultures after SRP and it occurred more frequently immediately after treatment; however, 19% of the patients still had microorganisms in the bloodstream 30 min. after the procedure. The periodontopathic microorganisms more frequently identified were Porphyromonas gingivalis and Micromonas micros. Campylobacter spp., Eikenella corrodens, Tannerella forsythensis, Fusobacterium spp. and Prevotella intermedia were isolated less often. Actinomyces spp. were also found frequently during bacteraemia after SRP. SRP induced bacteraemia associated with anaerobic bacteria, especially in patients with periodontal disease.
Havig, Stine Marie; Høiseth, Gudrun; Strand, Maren Cecilie; Karinen, Ritva Anneli; Brochmann, Gerd-Wenche; Strand, Dag Helge; Bachs, Liliana; Vindenes, Vigdis
2017-07-01
Several publications have suggested increasing cannabis potency over the last decade, which, together with lower amounts of cannabidiol (CBD), could contribute to an increase in adverse effects after cannabis smoking. Naturalistic studies on tetrahydrocannabinol (THC) and CBD in blood samples are, however, missing. This study aimed to investigate the relationship between THC- and CBD concentrations in blood samples among cannabis users, and to compare cannabinoid concentrations with the outcome of a clinical test of impairment (CTI) and between traffic accidents and non-accident driving under the influence of drugs (DUID)-cases. Assessment of THC- and CBD contents in cannabis seizures was also included. THC- and CBD concentrations in blood samples from subjects apprehended in Norway from April 2013-April 2015 were included (n=6134). A CTI result was compared with analytical findings in cases where only THC and/or CBD were detected (n=705). THC- and CBD content was measured in 41 cannabis seizures. Among THC-positive blood samples, 76% also tested positive for CBD. There was a strong correlation between THC- and CBD concentrations in blood samples (Pearson's r=0.714, p<0.0005). Subjects judged as impaired by a CTI had significantly higher THC- (p<0.001) and CBD (p=0.008) concentrations compared with not impaired subjects, but after multivariate analyses, impairment could only be related to THC concentration (p=0.004). Analyzing seizures revealed THC/CBD ratios of 2:1 for hashish and 200:1 for marijuana. More than ¾ of the blood samples testing positive for THC, among subjects apprehended in Norway, also tested positive for CBD, suggesting frequent consumption of high CBD cannabis products. The simultaneous presence of CBD in blood does, however, not appear to affect THC-induced impairment on a CTI. Seizure sample analysis did not reveal high potency cannabis products, and while CBD content appeared high in hashish, it was almost absent in marijuana. Copyright © 2017. Published by Elsevier B.V.
Foroughi, Maryam; Montazeri, Saman Mohaghegh; SeyedAlinaghi, SeyedAhmad; Badie, Banafshe Moradmand; Heiydarpour, Pourya; Roosta, Neda; Rasoolinejad, Mehrnaz; Cochak, Hamid Emadi
2011-01-01
It is estimated that one third of the world's population is latently infected with tuberculosis (TB). The HIV epidemic fuels the TB epidemic by increasing the risk of reactivation of latent TB infection and by facilitating a more rapid progression of TB disease. Although the incidence of TB is constant or decreasing in many regions of the world, rates remain high in developing countries as a consequence of the HIV epidemic. This study was conducted as a collaboration of the Infectious Diseases department of Imam Khomeini Hospital with the Microbiology department of Tehran University of Medical Sciences. The hospital dataset of 94 patients admitted with TB during 2003-2005 was reviewed. We aimed to study factors correlating with positive blood culture including age, sex, immune deficiency status, HIV serology and SIRS (Systemic Inflammatory Response Syndrome) status. In this study, we found that positive blood cultures are more frequent in patients less than 45 years old. Positive blood cultures were also more frequent in HIV infected patients and there was a significant correlation between blood culture and SIRS status. Therefore, we recommend that we obtain blood cultures from these high-risk groups in order to increase early detection of TB.
1999-01-01
Evaluation of peripheral blood mononuclear cells, urine and throat cultures samples for the presence of mycoplasma or ureaplasma organisms by...c) by PCR with a universal mycoplasma primer. Mycoplasma or ureaplasma were detected frequently in urine and throat swabs, however no significant
Microbiology of peritonsillar abscess in the South Estonian population
Vaikjärv, Risto; Kasenõmm, Priit; Jaanimäe, Liis; Kivisild, Ave; Rööp, Tiiu; Sepp, Epp; Mändar, Reet
2016-01-01
Objective The first aim of this study was to compare the microbiota of different locations (pus, tonsillar fossa, blood) in peritonsillar abscess (PTA) patients in order to optimize the sampling scheme. The second aim was to estimate the occurrence of tonsillitis episodes and macroscopic oropharyngeal signs characteristic of recurrent tonsillitis in PTA patients. Methods The study group consisted of 22 consecutive patients with PTA undergoing bilateral tonsillectomy. The PTA was punctured; pus and tonsillar fossa biopsy samples and the peripheral blood cultures were collected. The index of tonsillitis was calculated by multiplying the number of tonsillitis episodes per year by the morbidity period in years. Macroscopic oropharyngeal signs were evaluated and they were as follows: tonsillar sclerosis, obstruction of the tonsillar crypts, scar tissue on tonsils, cryptic debris, and lymphatic tissue aggregates. Results The cultures of the pus were positive in 16 out of 22 patients and the cultures of the tonsillar fossa samples were positive in all cases. In total, 62 different organisms were found from tonsillar fossa, pus, and blood samples, which belonged to 5 different phyla and 18 different families. In the tonsillar fossa, the most frequent bacteria found were Streptococcus spp. In pus samples, the most frequently found bacteria were Streptococcus spp. and bacteria from the Streptococcus milleri group. Conclusion PTA patients had mixed anaerobic and aerobic microbiota both in the tissue of the tonsillar fossa and the pus of the peritonsillar space. We demonstrated that the tonsillar fossa specimen is a better material for microbiological analyses, because it reveals more bacteria per culture. PTA patients usually have a low number of tonsillitis episodes in their previous history, but a relatively high number of macroscopic oropharyngeal signs, indicating the sclerotic process in palatal tonsils. PMID:27113570
Lee, Hwan Young; Jung, Sang-Eun; Lee, Eun Hee; Yang, Woo Ick; Shin, Kyoung-Jin
2016-09-01
The ability to predict the type of tissues or cells from molecular profiles of crime scene samples has important practical implications in forensics. A previously reported multiplex assay using DNA methylation markers could only discriminate between 4 types of body fluids: blood, saliva, semen, and the body fluid which originates from female reproductive organ. In the present study, we selected 15 menstrual blood-specific CpG marker candidates based on analysis of 12 genome-wide DNA methylation profiles of vaginal fluid and menstrual blood. The menstrual blood-specificity of the candidate markers was confirmed by comparison with HumanMethylation450 BeadChip array data obtained for 58 samples including 12 blood, 12 saliva, 12 semen, 3 vaginal fluid, and 19 skin epidermis samples. Among 15CpG marker candidates, 3 were located in the promoter region of the SLC26A10 gene, and 2 of them (cg09696411 and cg18069290) showed high menstrual blood specificity. DNA methylation at the 2CpG markers was further tested by targeted bisulfite sequencing of 461 additional samples including 49 blood, 52 saliva, 34 semen, 125 vaginal fluid, and 201 menstrual blood. Because the 2 markers showed menstrual blood-specific methylation patterns, we modified our previous multiplex methylation SNaPshot reaction to include these 2 markers. In addition, a blood marker cg01543184 with cross reactivity to semen was replaced with cg08792630, and a semen-specific unmethylation marker cg17621389 was removed. The resultant multiplex methylation SNaPshot allowed positive identification of blood, saliva, semen, vaginal fluid and menstrual blood using the 9CpG markers which show a methylation signal only in the target body fluids. Because of the complexity in cell composition, menstrual bloods produced DNA methylation profiles that vary with menstrual cycle and sample collection methods, which are expected to provide more insight into forensic menstrual blood test. Moreover, because the developed multiplex methylation SNaPshot reaction includes the 4CpG markers of which specificities have been confirmed by multiple studies, it will facilitate confirmatory tests for body fluids that are frequently observed in forensic casework. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Chen, Tai-Di; Chen, Ding-Ping; Wang, Wei-Ting; Sun, Chien-Feng
2014-01-01
Background Glycophorin variants of the MNSs blood group are important in Taiwan. For more than 20 years, screening for the most frequent irregular antibody, anti-‘Mia’, has been conducted by using ‘Mia’(+) RBCs, with a significant success. However, the sensitivity and the specificity of this screening strategy have never been validated, and the true incidences of different glycophorin variants in Taiwan have been in controversy. Also, the significance of another less frequent and usually separately reported variant, Sta, has never been evaluated. Methodology/Principal Findings We ran a population-based screening (from unselected patients in our hospital) for MNSs blood group glycophorin variants by PCR-sequencing method. GP.Mur (Mil.III) was confirmed by sequence from 57 out of 1027 samples (5.6%), and there was no other Miltenberger subtype glycophorin variant found. Glycophorin variant Sta was found from 35 out of 1027 samples (3.4%). In contrast to anti-‘Mia’, which is the most frequently identified irregular antibody in Taiwan, the prevalence of anti-Sta was only 0.13% as determined by serologic method. In addition, two new alleles for Sta were found and reported. Conclusion/Significance We confirm the long-standing assumption that GP.Mur is the only prevalent Miltenberger subtype in Taiwan. The current anti-‘Mia’ screening method used in Taiwan, although neither sensitive nor specific, is still a suitable practice. Although Sta antigen has a high prevalence in Taiwan, routine screening for anti-Sta is not warranted based on current evidence. PMID:24858913
Avalos-Téllez, Rosalía; Carrillo-Casas, Erika M; Atilano-López, Daniel; Godínez-Reyes, Carlos R; Díaz-Aparicio, Efrén; Ramírez-Delgado, David; Ramírez-Echenique, María F; Leyva-Leyva, Margarita; Suzán, Gerardo; Suárez-Güemes, Francisco
2016-04-28
The California sea lion ( Zalophus californianus ), a permanent inhabitant of the Gulf of California in Mexico, is susceptible to pathogenic Leptospira spp. infection, which can result in hepatic and renal damage and may lead to renal failure and death. During summer 2013, we used the microscopic agglutination test (MAT) to investigate the prevalence of anti-Leptospira antibodies in blood of clinically healthy sea lion pups from seven rookery islands on the Pacific Coast of Baja California (Pacific Ocean) and in the Gulf of California. We also used PCR to examine blood for Leptospira DNA. Isolation of Leptospira in liquid media was unsuccessful. We found higher antibody prevalence in sea lions from the rookery islands in the gulf than in those from the Pacific Coast. Antibodies against 11 serovars were identified in the Gulf of California population; the most frequent reactions were against serovars Bataviae (90%), Pyrogenes (86%), Wolffi (86%), Celledoni (71%), and Pomona (65%). In the Pacific Ocean population, MAT was positive against eight serovars, where Wolffi (88%), Pomona (75%), and Bataviae (70%) were the most frequent. Serum samples agglutinated with more than one Leptospira serovar. The maximum titer was 3,200. Each island had a different serology profile, and islands combined showed a distinct profile for each region. We detected pathogenic Leptospira DNA in 63% of blood samples, but we found no saprophytic Leptospira. Positive PCR results were obtained in blood samples with high and low MAT titers. Together, these two methods enhance the diagnosis and interpretation of sea lion leptospirosis. Our results may be related to human activities or the presence of other reservoirs with which sea lions interact, and they may also be related to sea lion stranding.
Moore, M.K.; Cicnjak-Chubbs, L.; Gates, R.J.
1994-01-01
A selective enrichment procedure, using two new selective media, was developed to isolate Pasteurella multocida from wild birds and environmental samples. These media were developed by testing 15 selective agents with six isolates of P. multocida from wild avian origin and seven other bacteria representing genera frequently found in environmental and avian samples. The resulting media—Pasteurella multocida selective enrichment broth and Pasteurella multocida selective agar—consisted of a blood agar medium at pH 10 containing gentamicin, potassium tellurite, and amphotericin B. Media were tested to determine: 1) selectivity when attempting isolation from pond water and avian carcasses, 2) sensitivity for detection of low numbers of P. multocida from pure and mixed cultures, 3) host range specificity of the media, and 4) performance compared with standard blood agar. With the new selective enrichment procedure, P. multocida was isolated from inoculated (60 organisms/ml) pond water 84% of the time, whereas when standard blood agar was used, the recovery rate was 0%.
Elges, Sandra; Arnold, Renate; Liesenfeld, Oliver; Kofla, Grzegorz; Mikolajewska, Agata; Schwartz, Stefan; Uharek, Lutz; Ruhnke, Markus
2017-12-01
We prospectively evaluated a multiplex real-time PCR assay (SeptiFast, SF) in a cohort of patients undergoing allo-BMT in comparison to an in-house PCR method (IH-PCR). Overall 847 blood samples (mean 8 samples/patient) from 104 patients with haematological malignancies were analysed. The majority of patients had acute leukaemia (62%) with a mean age of 52 years (54% female). Pathogens could be detected in 91 of 847 (11%) samples by SF compared to 38 of 205 (18.5%) samples by BC, and 57 of 847 (6.7%) samples by IH-PCR. Coagulase-negative staphylococci (n=41 in SF, n=29 in BC) were the most frequently detected bacteria followed by Escherichia coli (n=9 in SF, n=6 in BC). Candida albicans (n=17 in SF, n=0 in BC, n=24 in IH-PCR) was the most frequently detected fungal pathogen. SF gave positive results in 5% of samples during surveillance vs in 26% of samples during fever episodes. Overall, the majority of blood samples gave negative results in both PCR methods resulting in 93% overall agreement resulting in a negative predictive value of 0.96 (95% CI: 0.95-0.97), and a positive predictive value of 0.10 (95% CI: -0.01 to 0.21). SeptiFast appeared to be superior over BC and the IH-PCR method. © 2017 Blackwell Verlag GmbH.
Prevalence of HCV among the young male blood donors of Quetta region of Balochistan, Pakistan
2013-01-01
Background Hepatitis C, caused by hepatitis C virus (HCV) is a contagious disease of the liver which infects more than 170 million people world-wide and around 16 million in Pakistan. HCV associated infection spreads mainly by blood-to-blood contact. In recent years, many studies have been conducted to determine the prevalence of HCV infection in Pakistan; however, no data is available on HCV infection from the largest province of Pakistan. Therefore, the present study focuses on the prevalence of HCV infection in the young male blood donor population of Quetta region of Balochistan, Pakistan. Methods A total of 356 blood samples were collected from blood donors (age range 17–25 years) at Combined Military Hospital (CMH), Quetta, Balochistan, Pakistan. Blood samples were screened for HCV positivity by Immunochromatographic test (ICT) and Enzyme Linked Immunosorbant Assay (ELISA). Results Out of 356 blood samples, the overall HCV prevalence was 20.8%. Among the HCV positive cases, the age group with 25 years was more frequently infected with a prevalence of 26.3%. Conclusions The present study provides the preliminary information about high HCV prevalence among the young male donor population in Balochistan province. This data may be helpful in formulating public health strategy for the prevention of risk factors associated with spreading of the disease. Furthermore, we recommend that in public sector hospitals and health care units ELISA should be preferred for anti-HCV detection over ICT. PMID:23497435
Prevalence of HCV among the young male blood donors of Quetta region of Balochistan, Pakistan.
Khan, Ayesha; Tareen, Abdul Malik; Ikram, Aamer; Rahman, Hazir; Wadood, Abdul; Qasim, Muhammad; Khan, Kalimullah
2013-03-13
Hepatitis C, caused by hepatitis C virus (HCV) is a contagious disease of the liver which infects more than 170 million people world-wide and around 16 million in Pakistan. HCV associated infection spreads mainly by blood-to-blood contact. In recent years, many studies have been conducted to determine the prevalence of HCV infection in Pakistan; however, no data is available on HCV infection from the largest province of Pakistan. Therefore, the present study focuses on the prevalence of HCV infection in the young male blood donor population of Quetta region of Balochistan, Pakistan. A total of 356 blood samples were collected from blood donors (age range 17-25 years) at Combined Military Hospital (CMH), Quetta, Balochistan, Pakistan. Blood samples were screened for HCV positivity by Immunochromatographic test (ICT) and Enzyme Linked Immunosorbant Assay (ELISA). Out of 356 blood samples, the overall HCV prevalence was 20.8%. Among the HCV positive cases, the age group with 25 years was more frequently infected with a prevalence of 26.3%. The present study provides the preliminary information about high HCV prevalence among the young male donor population in Balochistan province. This data may be helpful in formulating public health strategy for the prevention of risk factors associated with spreading of the disease. Furthermore, we recommend that in public sector hospitals and health care units ELISA should be preferred for anti-HCV detection over ICT.
Zhang, Feng; Liu, Yang; Zhang, Hengdong; Ban, Yonghong; Wang, Jianfeng; Liu, Jian; Zhong, Lixing; Chen, Xianwen; Zhu, Baoli
2016-01-01
Lead pollution incidents have occurred frequently in mainland China, which has caused many lead poisoning incidents. This paper took a battery recycling factory as the subject, and focused on measuring the blood lead levels of environmental samples and all the children living around the factory, and analyzed the relationship between them. We collected blood samples from the surrounding residential area, as well as soil, water, vegetables. The atomic absorption method was applied to measure the lead content in these samples. The basic information of the generation procedure, operation type, habit and personal protect equipment was collected by an occupational hygiene investigation. Blood lead levels in 43.12% of the subjects exceeded 100 μg/L. The 50th and the 95th percentiles were 89 μg/L and 232 μg/L for blood lead levels in children, respectively, and the geometric mean was 94 μg/L. Children were stratified into groups by age, gender, parents’ occupation, distance and direction from the recycling plant. The difference of blood lead levels between groups was significant (p < 0.05). Four risk factors for elevated blood lead levels were found by logistic regression analysis, including younger age, male, shorter distance from the recycling plant, and parents with at least one working in the recycling plant. The rate of excess lead concentration in water was 6.25%, 6.06% in soil and 44.44% in leaf vegetables, which were all higher than the Chinese environment standards. The shorter the distance to the factory, the higher the value of BLL and lead levels in vegetable and environment samples. The lead level in the environmental samples was higher downwind of the recycling plant. PMID:27240393
Zhang, Feng; Liu, Yang; Zhang, Hengdong; Ban, Yonghong; Wang, Jianfeng; Liu, Jian; Zhong, Lixing; Chen, Xianwen; Zhu, Baoli
2016-05-28
Lead pollution incidents have occurred frequently in mainland China, which has caused many lead poisoning incidents. This paper took a battery recycling factory as the subject, and focused on measuring the blood lead levels of environmental samples and all the children living around the factory, and analyzed the relationship between them. We collected blood samples from the surrounding residential area, as well as soil, water, vegetables. The atomic absorption method was applied to measure the lead content in these samples. The basic information of the generation procedure, operation type, habit and personal protect equipment was collected by an occupational hygiene investigation. Blood lead levels in 43.12% of the subjects exceeded 100 μg/L. The 50th and the 95th percentiles were 89 μg/L and 232 μg/L for blood lead levels in children, respectively, and the geometric mean was 94 μg/L. Children were stratified into groups by age, gender, parents' occupation, distance and direction from the recycling plant. The difference of blood lead levels between groups was significant (p < 0.05). Four risk factors for elevated blood lead levels were found by logistic regression analysis, including younger age, male, shorter distance from the recycling plant, and parents with at least one working in the recycling plant. The rate of excess lead concentration in water was 6.25%, 6.06% in soil and 44.44% in leaf vegetables, which were all higher than the Chinese environment standards. The shorter the distance to the factory, the higher the value of BLL and lead levels in vegetable and environment samples. The lead level in the environmental samples was higher downwind of the recycling plant.
Riboflavin and ultraviolet light reduce the infectivity of Babesia microti in whole blood.
Tonnetti, Laura; Thorp, Aaron M; Reddy, Heather L; Keil, Shawn D; Goodrich, Raymond P; Leiby, David A
2013-04-01
Babesia microti is the parasite most frequently transmitted by blood transfusion in the United States. Previous work demonstrated the efficacy of riboflavin (RB) and ultraviolet (UV) light to inactivate B.microti in apheresis plasma and platelet units. In this study we investigated the effectiveness of RB and UV light to reduce the levels of B.microti in whole blood (WB). WB units were spiked with B. microti-infected hamster blood. Spearman-Karber methods were used to calculate infectivity of each sample in terms of hamster infectious dose 50% (HID50 ) value. After RB addition, the units were illuminated with 80 J/mLRBC UV light. Two samples were collected: one before illumination and one after illumination. The samples were serially diluted and dilutions injected into a group of five naive hamsters. Four weeks postinoculation (PI), blood was collected from the animals and evaluated by microscopic observation. One pilot study showed a good dose response in the animals and demonstrated that sample infectivity could be calculated in terms of an HID50 . Three additional replicates were performed in the same manner as the pilot study, but with fewer dilutions. Infectivity values were consistent between the experiments and were used to calculate log reduction. The posttreatment reduction of B. microti for all the experiments was more than 5 log. The data collected indicate that use of RB and UV is able to decrease the parasite load in WB units thus reducing the risk of transfusion-transmitted B. microti from blood components containing B. microti-infected RBCs. © 2012 American Association of Blood Banks.
Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S
2014-09-15
Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test for antibodies in the ICT and compared to ICT results using thawed plasma (same initial source). Sensitivity and specificity of the ICT using DBS were determined by using ICT results from traditional blood collection samples for comparison. After 1 month, DBS samples showed 100% sensitivity and specificity when compared to ICT results on thawed plasma samples collected by traditional venipuncture. After six months storage at room temperature, DBS samples demonstrated 79% sensitivity and 100% specificity compared to traditional blood collection. Results from this study indicate that dried blood spot collection may be a useful tool for screening dogs for antibodies to L. infantum with the ICT assay. Copyright © 2014 Elsevier B.V. All rights reserved.
Cermáková, Zuzana; Prásil, Petr; Valenta, Zbynek; Förstl, Miroslav; Plísková, Lenka; Bolehovská, Radka
2009-08-01
Infections caused by pathogenic protozoan Toxoplasma gondii in our geographic area is the most frequent parasitic infection; Czech Republic declares seroprevalence approx. 30 %. Diagnosis of toxoplasmosis is mostly based on serological methods are used (EIA IgM, IgA, IgE, IgG and avidity in IgG, Western Blot, complement fixation). According to positive results of these tests diagnosis of acute toxoplasmosis is established. In our retrospective study we tried to evaluate results of T. gondii DNA positivity from blood samples by PCR compared with positive markers of acute infection in patients before specific therapy was initiated. In accordance with literature we concluded, that in routine examination of immunocompetent outpatients of Clinic of Infectious Diseases from the moment of 4 weeks after lymphatic nodes swelling protozoan DNA detection in blood sample is not possible.
Restless legs syndrome, pica, and iron status in blood donors.
Spencer, Bryan R; Kleinman, Steven; Wright, David J; Glynn, Simone A; Rye, David B; Kiss, Joseph E; Mast, Alan E; Cable, Ritchard G
2013-08-01
The association of blood donation-related iron deficiency with pica or restless legs syndrome (RLS) remains poorly elucidated. This study evaluated the prevalence of RLS and pica in blood donors completing the REDS-II Iron Status Evaluation (RISE) study. RISE enrolled 2425 blood donors in a prospective cohort study; 1334 donors provided blood samples to characterize iron status and answered a questionnaire inquiring into symptoms of RLS and pica at a final visit after 15 to 24 months of follow-up. Associations between both conditions and iron status were evaluated. There were 9 and 20% of donors reporting symptoms of probable or probable/possible RLS, respectively. Iron depletion and donation intensity were not predictive of RLS. Pica was reported by 65 donors (5.5%), half of whom reported daily cravings. Prevalence of pica increased with degree of iron depletion in women (2% in iron-replete females, 13% in those with ferritin < 12 ng/mL), but not in men. Probable RLS and pica coexpressed in eight individuals, but no more frequently than expected by chance. RLS and pica have been associated with iron deficiency in nondonor populations. This study indicates a potentially high prevalence of RLS in frequent blood donors but shows no association with iron status or donation intensity. Low iron stores were associated with higher prevalence of pica, but only in females. Furthermore, the results are incompatible with RLS and pica sharing a common pathophysiology. © 2013 American Association of Blood Banks.
Lindhardt, T B; Hesse, B; Gadsbøll, N
1997-01-01
The purpose of this study was to determine the accuracy of determinations of left ventricular ejection fraction (LVEF) by a nonimaging miniature nuclear detector system (Cardioscint) and to evaluate the feasibility of long-term LVEF monitoring in patients admitted to the coronary care unit, with special reference to the blood-labeling technique. Cardioscint LVEF values were compared with measurements of LVEF by conventional gamma camera radionuclide ventriculography in 33 patients with a wide range of LVEF values. In 21 of the 33 patients, long-term monitoring was carried out for 1 to 4 hours (mean 186 minutes), with three different kits: one for in vivo and two for in vitro red blood cell labeling. The stability of the labeling was assessed by determination of the activity of blood samples taken during the first 24 hours after blood labeling. The agreement between Cardioscint LVEF and gamma camera LVEF was good with automatic background correction (r = 0.82; regression equation y = 1.04x + 3.88) but poor with manual background correction (r = 0.50; y = 0.88x - 0.55). The agreement was highest in patients without wall motion abnormalities. The long-term monitoring showed no difference between morning and afternoon Cardioscint LVEF values. Short-lasting fluctuations in LVEFs greater than 10 EF units were observed in the majority of the patients. After 24 hours, the mean reduction in the physical decay-corrected count rate of the blood samples was most pronounced for the two in vitro blood-labeling kits (57% +/- 9% and 41% +/- 3%) and less for the in vivo blood-labeling kit (32% +/- 26%). This "biologic decay" had a marked influence on the Cardioscint monitoring results, demanding frequent background correction. A fairly accurate estimate of LVEF can be obtained with the nonimaging Cardioscint system, and continuous bedside LVEF monitoring can proceed for hours with little inconvenience to the patients. Instability of the red blood cell labeling during long-term monitoring necessitates frequent background correction.
Niknafs, Pedram; Norouzi, Elahe; Bahman Bijari, Bahareh; Baneshi, Mohammad Reza
2015-01-01
Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS, 7.2% were found to have one or more of the followings: acidosis, hypercapnia, or hypoxemia. We found that pulse oximetry in the detection of hyperoxemia had a good validity to appropriately manage patients without blood gas analysis. However, the validity of pulse oximetry was not good enough to detect acidosis, hypercapnia, and hypoxemia. PMID:25999627
Scheer, Christian S; Fuchs, Christian; Gründling, Matthias; Vollmer, Marcus; Bast, Juliane; Bohnert, Jürgen A; Zimmermann, Kathrin; Hahnenkamp, Klaus; Rehberg, Sebastian; Kuhn, Sven-Olaf
2018-06-04
Sepsis guidelines recommend obtaining blood cultures before starting anti-infective therapy in patients with sepsis. However, little is known how antibiotic treatment prior to sampling affects bacterial growth. The aim of this study was to compare the results of blood cultures drawn prior to and under antibiotic therapy. Prospective clinical cohort study of septic patients. Adult ICU patients with 2 or 3 blood culture (BC) sets at the beginning of sepsis between 2010 and 2017 were included. Patients with blood culture samplings obtained prior to antibiotic therapy were compared to patients with samplings under antibiotic therapy. Blood culture positivity, defined as microbiological pathogen finding, was compared between the groups. Logistic regression was performed to adjust the impact of different factors with respect to blood culture positivity. In total, 559 patients with 1364 blood culture sets at the beginning of sepsis were analyzed. BC positivity was 50.6% (78/154) among septic patients who did not receive antibiotics and only 27.7% (112/405) in those who were already under antibiotics (P<0.001). Logistic regression revealed antibiotic therapy as an independent factor for less pathogen identification (Odds ratio 0.4; 95%CI 0.3-0.6). Gram-positive pathogens (28.3%(111/392) vs. 11.9%(116/972);P<0.001) and also gram-negative pathogens (16.3%(64/392) vs. 9.3%(90/972);P<0.001) were more frequent in BC sets drawn prior to antibiotic therapy compared to sets under antibiotics. Obtaining blood cultures under antibiotic therapy is associated with a significant loss of pathogen detection. This strongly emphasizes the current recommendation to obtain blood cultures prior to antibiotic administration in patients with sepsis. Copyright © 2018. Published by Elsevier Ltd.
Tavakol, Najmeh; Kheiri, Soleiman; Sedehi, Morteza
2016-01-01
Time to donating blood plays a major role in a regular donor to becoming continues one. The aim of this study was to determine the effective factors on the interval between the blood donations. In a longitudinal study in 2008, 864 samples of first-time donors in Shahrekord Blood Transfusion Center, capital city of Chaharmahal and Bakhtiari Province, Iran were selected by a systematic sampling and were followed up for five years. Among these samples, a subset of 424 donors who had at least two successful blood donations were chosen for this study and the time intervals between their donations were measured as response variable. Sex, body weight, age, marital status, education, stay and job were recorded as independent variables. Data analysis was performed based on log-normal hazard model with gamma correlated frailty. In this model, the frailties are sum of two independent components assumed a gamma distribution. The analysis was done via Bayesian approach using Markov Chain Monte Carlo algorithm by OpenBUGS. Convergence was checked via Gelman-Rubin criteria using BOA program in R. Age, job and education were significant on chance to donate blood (P<0.05). The chances of blood donation for the higher-aged donors, clericals, workers, free job, students and educated donors were higher and in return, time intervals between their blood donations were shorter. Due to the significance effect of some variables in the log-normal correlated frailty model, it is necessary to plan educational and cultural program to encourage the people with longer inter-donation intervals to donate more frequently.
Gapany, Christophe; Tercier, Stéphane; Diezi, Manuel; Clement, Chantal; Lemay, Katy; Joseph, Jean-Marc
2011-01-01
Totally implanted vascular (TIVA) ports are used in children for repeated blood samples or intravenous treatments. We have recently published a prospective evaluation of surgical incidents and early complications associated with these devices. This work is the final part of the same study, assessing late complications over a follow-up of 2 yrs. From January 2006 to January 2008, children older than 1 yr of age with a diagnosis of solid or blood cell malignancy were included. Insertion technique and care of the device were standardized. Every manipulation was prospectively recorded by specialized nurses. Obstruction was documented clinically. When bacteremia was suspected, routine central and peripheral blood cultures were drawn. Forty-five consecutive patients were enrolled in the study. Mean age at the time of the procedure was 8.5 yrs. There was no catheter-related infection within the first 4 weeks post-surgery. No device had to be removed because of infection or obstruction during follow-up. Frequent accesses to the port (=3 per day over a 10-day period) were associated with an 8-fold risk of infection. Insertion and use of TIVA devices were frequently associated with complications. No device had to be removed because of infection or obstruction over the follow-up period, although no prophylactic antibiotic agent was used. Restrictive use of antibiotics may prevent opportunistic infection. Frequent access to the device was significantly associated with line infection (odds ratio=8.43). No risk factor was identified for obstruction which occurred at a rate of 5.3 per 10,000 accesses.
Analysis of Platelet-Rich Plasma Extraction
Fitzpatrick, Jane; Bulsara, Max K.; McCrory, Paul Robert; Richardson, Martin D.; Zheng, Ming Hao
2017-01-01
Background: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. Purpose: To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. Study Design: Controlled laboratory study. Methods: Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. Results: Three kits taking samples from the “buffy coat layer” were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. Conclusion: This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. Clinical Relevance: The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use. PMID:28210651
Marín, M-J; Figuero, E; González, I; O'Connor, A; Diz, P; Álvarez, M; Herrera, D; Sanz, M
2016-05-01
The prevalence and amounts of periodontal pathogens detected in bacteraemia samples after tooth brushing-induced by means of four diagnostic technique, three based on culture and one in a molecular-based technique, have been compared in this study. Blood samples were collected from thirty-six subjects with different periodontal status (17 were healthy, 10 with gingivitis and 9 with periodontitis) at baseline and 2 minutes after tooth brushing. Each sample was analyzed by three culture-based methods [direct anaerobic culturing (DAC), hemo-culture (BACTEC), and lysis-centrifugation (LC)] and one molecular-based technique [quantitative polymerase chain reaction (qPCR)]. With culture any bacterial isolate was detected and quantified, while with qPCR only Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were detected and quantified. Descriptive analyses, ANOVA and Chi-squared tests, were performed. Neither BACTEC nor qPCR detected any type of bacteria in the blood samples. Only LC (2.7%) and DAC (8.3%) detected bacteraemia, although not in the same patients. Fusobacterium nucleatum was the most frequently detected bacterial species. The disparity in the results when the same samples were analyzed with four different microbiological detection methods highlights the need for a proper validation of the methodology to detect periodontal pathogens in bacteraemia samples, mainly when the presence of periodontal pathogens in blood samples after tooth brushing was very seldom.
Restless Legs Syndrome, pica, and iron status in blood donors
Spencer, Bryan R.; Kleinman, Steven; Wright, David J.; Glynn, Simone A.; Rye, David B.; Kiss, Joseph E.; Mast, Alan E.; Cable, Ritchard G.
2014-01-01
BACKGROUND The association of blood donation related iron deficiency with pica or Restless Leg Syndrome (RLS) remains poorly elucidated. This study evaluated the prevalence of RLS and pica in blood donors completing the REDS-II Iron Status Evaluation (RISE) Study. STUDY DESIGN AND METHODS RISE enrolled 2425 blood donors in a prospective cohort study; 1334 donors provided blood samples to characterize iron status and answered a questionnaire inquiring into symptoms of RLS and pica at a final visit after 15–24 months of follow-up. Associations between both conditions and iron status were evaluated. RESULTS There were 9% and 20% of donors reporting symptoms of Probable or Probable/Possible RLS, respectively. Iron depletion and donation intensity were not predictive of RLS. Pica was reported by 65 donors (5.5%), half of whom reported daily cravings. Prevalence of pica increased with degree of iron depletion in women (2% in iron replete females, 13% in those with ferritin < 12ng/mL), but not in men. Probable RLS and pica co-expressed in 8 individuals, but no more frequently than expected by chance. CONCLUSION RLS and pica have been associated with iron deficiency in non-donor populations. This study indicates a potentially high prevalence of RLS in frequent blood donors but shows no association with iron status or donation intensity. Low iron stores were associated with higher prevalence of pica, but only in females. Furthermore, the results are incompatible with RLS and pica sharing a common pathophysiology. PMID:23763445
Erzen, Ivan; Zaletel Kragelj, Lijana
2003-10-01
To determine cadmium content in the most frequently consumed foods of plant origin grown in different regions of Slovenia, assess cadmium content in the biological materials (blood and hair) from Slovenian young men, and verify the hypothesis that the cadmium pollution of the environment varies across regions in Slovenia. We analyzed cadmium concentration in 982 composite samples of foods of plant origin, and determined the cadmium burden in the population by analyzing cadmium content in whole blood and hair samples from 742 randomly selected healthy men aged 18-26 years. There were significant differences in cadmium content in the analyzed foods with respect to the regions in Slovenia where were the foods of plant origin were produced (p<0.001). The median cadmium content in 463 blood specimens was 0.5 microg/L, and 4 ng/g in 245 hair specimens. Cadmium content in the blood and hair samples from study participants varied significantly across regions in Slovenia (p<0.001 and p<0.003, respectively). Cadmium content in foods of plant origin and cadmium burden in the blood showed only a weak correlation (Spearman's r=0.13), whereas the correlation between cadmium content in the foods and hair was much stronger (Spearman's r=0.55). Our research confirmed the hypothesis of regionally different environmental pollution with cadmium, and clearly showed the connection between cadmium burden in foods and in population in Slovenia.
Tien, Yu-Wen; Lee, Po-Huang; Wang, Shih-Ming; Hsu, Su-Ming; Chang, King-Jen
2002-01-01
This study was designed to show, in certain patients, that colonic epithelial cells can be present in peripheral blood while absent in portal venous blood. The circulating colorectal epithelial cells were detected by a reverse transcriptase-polymerase chain reaction assay, which involved amplifying guanylyl cyclase C transcripts. Portal venous and peripheral blood samples were obtained at intervals from 58 patients undergoing colorectal cancer surgery. Circulating colonic epithelial cells were more frequently detected in portal venous blood than in peripheral blood only before mobilization of the tumor-bearing colon segment in patients with tumors of Stage B. In five other patients, before mobilization of their tumor-bearing colon segments, and in another three patients, during the mobilization, colorectal epithelial cells were detected in peripheral blood but not in portal venous blood. These eight patients had Stage C or D tumors. In 8 of 58 patients, colorectal epithelial cells were detected in peripheral but not in portal venous blood. Metastatic deposits in lymphatic vessels or liver might be the source of these cells.
Teilmann, Anne Charlotte; Rozell, Björn; Kalliokoski, Otto; Hau, Jann; Abelson, Klas S P
2016-01-01
Automated blood sampling through a vascular catheter is a frequently utilized technique in laboratory mice. The potential immunological and physiological implications associated with this technique have, however, not been investigated in detail. The present study compared plasma levels of the cytokines IL-1β, IL-2, IL-6, IL-10, IL-17A, GM-CSF, IFN-γ and TNF-α in male NMRI mice that had been subjected to carotid artery catheterization and subsequent automated blood sampling with age-matched control mice. Body weight and histopathological changes in the surgical area, including the salivary glands, the heart, brain, spleen, liver, kidneys and lungs were compared. Catheterized mice had higher levels of IL-6 than did control mice, but other cytokine levels did not differ between the groups. No significant difference in body weight was found. The histology revealed inflammatory and regenerative (healing) changes at surgical sites of all catheterized mice, with mild inflammatory changes extending into the salivary glands. Several catheterized mice had multifocal degenerative to necrotic changes with inflammation in the heart, kidneys and livers, suggesting that thrombi had detached from the catheter tip and embolized to distant sites. Thus, catheterization and subsequent automated blood sampling may have physiological impact. Possible confounding effects of visceral damage should be assessed and considered, when using catheterized mouse models.
Factors Influencing Dental Patient Participation in Biobanking and Biomedical Research.
Hassona, Yazan; Ahram, Mamoun; Odeh, Noorah; Abu Gosh, Mais; Scully, Crispian
To study the willingness of dental patients to donate biospecimens for research purpose and to examine factors that may influence such a decision. A face-to-face interview was conducted using a pretested structured survey instrument on 408 adult dental patients attending a university hospital for dental care. Descriptive statistics were generated, and the x03C7;2 test was used to examine differences between groups. p values ≤0.5 were considered statistically significant. Of the 408 participants, only 71 (17.4%) had heard of the terms biobanking/biospecimens, but 293 (71.9%) approved of the idea of using biospecimens for biomedical research, and 228 (55.9%) were willing to donate biospecimens and give personal information for research purposes. In participants who were unwilling to participate in biobanking, fear of information leakage was the most frequently reported reason, while in participants who were willing to donate biospecimens, the potential to provide more effective and less costly treatments was the most frequently reported reason. The preferences of the 228 participants who were willing to donate biospecimens were as follows: give a sample of removed oral tissues including extracted teeth (n = 105, 46.1%), donate a blood sample (n = 52, 23%), donate a sample of saliva (n = 43, 18.6%), and give a urine sample (n = 28, 12.3%). Dental patients had a generally positive attitude towards biomedical research and biobanking. The most preferred types of biospecimens to donate in a dental setting were removed tissues, including extracted teeth and blood samples. © 2016 S. Karger AG, Basel.
Influence of the collection tube on metabolomic changes in serum and plasma.
López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D
2016-04-01
Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
[Precision and accuracy of "a pocket" pulse oximeter in Mexico City].
Torre-Bouscoulet, Luis; Chávez-Plascencia, Elizabeth; Vázquez-García, Juan Carlos; Pérez-Padilla, Rogelio
2006-01-01
Pulse oximeters are frequently used in the clinical practice and we must known their precision and accuracy. The objective was to evaluate the precision and accuracy of a "pocket" pulse oximeter at an altitude of 2,240 m above sea level. We tested miniature pulse oximeters (Onyx 9,500, Nonin Finger Pulse Oximeter) in 96 patients sent to the pulmonary laboratory for an arterial blood sample. Patients were tested with 5 pulse oximeters placed in each of the fingers of the hand oposite to that used for the arterial puncture. The gold standard was the oxygen saturation of the arterial blood sample. Blood samples had SaO2 of 87.2 +/- 11.0 (between 42.2 and 97.9%). Pulse oximeters had a mean error of 0.28 +/- 3.1%. SaO2 = (1.204 x SpO2) - 17.45966 (r = 0.92, p < 0.0001). Intraclass correlation coefficient between each of five pulse oximeters against the arterial blood standard ranged between 0.87 and 0.99. HbCO (2.4 +/- 0.6) did not affect the accuracy. The miniature oximeter Nonin is precise and accurate at 2,240 m of altitude. The observed levels of HbCO did not affect the performance of the equipment. The oximeter good performance, small size and low cost enhances its clinical usefulness.
[Investigation of West Nile virus RNA in blood donors by real-time RT-PCR].
Sahiner, Fatih; Avcı, Ismail Yaşar; Bedir, Orhan; Koru, Ozgür; Sener, Kenan; Yapar, Mehmet; Kubar, Ayhan
2012-07-01
West Nile virus (WNV), a member of Flaviviridae family, is an enveloped, icosahedral symmetric RNA virus. Primary reservoir hosts of WNV are birds, but the virus can cause various infections in humans and other mammals. The most common and natural transmission way of WNV infections is mosquito bites, however, humans can be infected by different routes. The most important non-mosquito transmission route is contaminated blood and blood products. In this study, we aimed to investigate the risk of WNV transmission through blood and blood products in Ankara, Turkey. The presence of WNV RNA was investigated by in house real-time reverse transcriptase-polymerase chain reaction (RT-PCR) in serum samples obtained from 729 healthy blood donors (mean age: 27.7 years; 711 were male), regardless of the donor's seropositivity status since the virus can be transmitted at the early stages of infection when seroconversion has not yet developed. Serum samples were collected in August-September 2009, the period when these infections are more frequent due to mosquito activity. The vast majority of donors (n= 702, 96.3%) have been inhabiting in Ankara and 569 (78%) of donors have had risk factors for arboviral infections (e.g. outdoor activity, mosquito and tick bites). WNV RNA was not detected by real-time RT-PCR analysis in any serum sample included in this study. According to the results of our study, it can be said that the risk of WNV transmission through blood and blood products is low in Ankara. However, WNV seropositivity was detected within the range of 0.56 to 2.4% among blood donors in previous studies and probable and confirmed WNV infections have been reported in our region. In addition, WNV outbreaks have emerged in some countries neighbouring Turkey recently. Thus, the risk of WNV transmission through blood and blood products should not be ignored and blood donor questionnaires should be evaluated in detail.
New method for determination of ten pesticides in human blood.
García-Repetto, R; Giménez, M P; Repetto, M
2001-01-01
An analytical method was developed for precise identification and quantitation of 10 pesticides in human blood. The pesticides studied, which have appeared frequently in actual cases, were endosulfan, lindane, parathion, ethyl-azinphos, diazinon, malathion, alachlor, tetradifon, fenthion and dicofol (o-p' and p-p' isomers). The current method replaces an earlier method which involved liquid-liquid extraction with a mixture of n-hexane-benzene (1 + 1). The extraction is performed by solid-phase extraction, with C18 cartridges and 2 internal standards, perthane and triphenylphosphate. Eluates were analyzed by gas chromatography (GC) with nitrogen-phosphorus and electrochemical detectors. Results were confirmed by GC-mass spectrometry in the electron impact mode. Blood blank samples spiked with 2 standard mixtures and an internal standard were used for quantitation. Mean recoveries ranged from 71.83 to 97.10%. Detection and quantitation limits are reported for each pesticide. Examples are provided to show the application of the present method to actual samples.
Bontempi, Iván A; Bizai, María L; Ortiz, Sylvia; Manattini, Silvia; Fabbro, Diana; Solari, Aldo; Diez, Cristina
2016-09-01
Different DNA markers to genotype Trypanosoma cruzi are now available. However, due to the low quantity of parasites present in biological samples, DNA markers with high copy number like kinetoplast minicircles are needed. The aim of this study was to complete a DNA assay called minicircle lineage specific-PCR (MLS-PCR) previously developed to genotype the T. cruzi DTUs TcV and TcVI, in order to genotype DTUs TcI and TcII and to improve TcVI detection. We screened kinetoplast minicircle hypervariable sequences from cloned PCR products from reference strains belonging to the mentioned DTUs using specific kDNA probes. With the four highly specific sequences selected, we designed primers to be used in the MLS-PCR to directly genotype T. cruzi from biological samples. High specificity and sensitivity were obtained when we evaluated the new approach for TcI, TcII, TcV and TcVI genotyping in twenty two T. cruzi reference strains. Afterward, we compared it with hybridization tests using specific kDNA probes in 32 blood samples from chronic chagasic patients from North Eastern Argentina. With both tests we were able to genotype 94% of the samples and the concordance between them was very good (kappa=0.855). The most frequent T. cruzi DTUs detected were TcV and TcVI, followed by TcII and much lower TcI. A unique T. cruzi DTU was detected in 18 samples meantime more than one in the remaining; being TcV and TcVI the most frequent association. A high percentage of mixed detections were obtained with both assays and its impact was discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Newmeyer, Matthew N; Swortwood, Madeleine J; Barnes, Allan J; Abulseoud, Osama A; Scheidweiler, Karl B; Huestis, Marilyn A
2016-12-01
There is increasing interest in markers of recent cannabis use because following frequent cannabis intake, Δ 9 -tetrahydrocannabinol (THC) may be detected in blood for up to 30 days. The minor cannabinoids cannabidiol, cannabinol (CBN), and THC-glucuronide were previously detected for ≤2.1 h in frequent and occasional smokers' blood after cannabis smoking. Cannabigerol (CBG), Δ 9 -tetrahydrocannabivarin (THCV), and 11-nor-9-carboxy-THCV might also be recent use markers, but their blood pharmacokinetics have not been investigated. Additionally, while smoking is the most common administration route, vaporization and edibles are frequently used. We characterized blood pharmacokinetics of THC, its phase I and phase II glucuronide metabolites, and minor cannabinoids in occasional and frequent cannabis smokers for 54 (occasional) and 72 (frequent) hours after controlled smoked, vaporized, and oral cannabis administration. Few differences were observed between smoked and vaporized blood cannabinoid pharmacokinetics, while significantly greater 11-nor-9-carboxy-THC (THCCOOH) and THCCOOH-glucuronide concentrations occurred following oral cannabis. CBG and CBN were frequently identified after inhalation routes with short detection windows, but not detected following oral dosing. Implementation of a combined THC ≥5 μg/L plus THCCOOH/11-hydroxy-THC ratio <20 cutoff produced detection windows <8 h after all routes for frequent smokers; no occasional smoker was positive 1.5 h or 12 h following inhaled or oral cannabis, respectively. Vaporization and smoking provide comparable cannabinoid delivery. CBG and CBN are recent-use cannabis markers after cannabis inhalation, but their absence does not exclude recent use. Multiple, complimentary criteria should be implemented in conjunction with impairment observations to improve interpretation of cannabinoid tests. Clinicaltrials.gov Identifier: NCT02177513. © 2016 American Association for Clinical Chemistry.
Irace, Concetta; Carallo, Claudio; Scavelli, Faustina; Loprete, Antonio; Merante, Valentina; Gnasso, Agostino
2012-01-01
A direct relationship between blood pressure and viscosity has frequently been reported, although clear data are not available. To better understand the relationship between these two variables, we evaluated blood viscosity and blood pressure in a group of healthy subjects without cardiovascular risk factors. Healthy subjects were selected from participants in a campaign of prevention of cardiovascular disease (n = 103). They underwent blood sampling for measurement of plasma and blood viscosity, haematocrit, blood lipids and glucose. The quantity and distribution of body fat was assessed by body mass index and waist/hip ratio, respectively. Systolic blood pressure (SBP) correlated significantly with age (r = 0.222) and waist/hip ratio (r = 0.374). Diastolic blood pressure (DBP) correlated significantly with waist/hip ratio (r = 0.216), haematocrit (r = 0.333) and blood viscosity (r = 0.258). Multiple linear regression analyses demonstrated that the only variable significantly associated with SBP was age, while haematocrit was the only variable significantly associated with DBP. Blood viscosity was closely related to waist/hip ratio. These findings show that SBP, in healthy subjects, is not influenced by haematocrit and blood viscosity. In contrast, DBP is related to the values of haematocrit. Among classical cardiovascular risk factors, waist/hip ratio is closely related to blood viscosity.
Determination of personal care products -benzophenones and parabens- in human menstrual blood.
Jiménez-Díaz, I; Iribarne-Durán, L M; Ocón, O; Salamanca, E; Fernández, M F; Olea, N; Barranco, E
2016-11-01
Benzophenones and parabens are synthetic chemicals used in many personal care products, foods and pharmaceuticals. Benzophenones are used to protect the skin and materials from the adverse effects of UV-radiation, and parabens are used as preservatives. Despite their widespread occurrence and proven endocrine disrupting activity, relatively little is known about human exposure to these compounds. In the present work, an analytical method based on sample treatment using dispersive liquid-liquid microextraction (DLLME) for the extraction of six benzophenones (benzophenone-1, -2, -3, -6, -8 and 4-hydroxybenzophenone) and four parabens (methyl-, ethyl-, propyl- and butyl- paraben) from human menstrual blood samples, followed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis, is proposed and validated. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. The limits of detection ranged from 0.1 to 0.3ngmL -1 , with recoveries of 93.8% to 108.9%, and precision (evaluated as relative standard deviation) lower than 14% for all selected compounds. This method was successfully applied for the determination of the target compounds in 25 samples of human menstrual blood. Methylparaben and benzophenone-3 were the most frequently detected compounds (96%). Copyright © 2016 Elsevier B.V. All rights reserved.
Specimen rejection in laboratory medicine: Necessary for patient safety?
Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz
2015-01-01
The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety.
Child, D F; Williams, C P
1982-06-01
Diabetic control was assessed in 82 established insulin-dependent diabetics using a microcapillary system for home preprandial blood glucose sampling. At initial assessment control in the majority (62%) was found to be unsatisfactory (at least 1 preprandial blood glucose greater than 13.0 mmol/l or frequent and severe hypoglycaemia). Sixty-three of these patients were assessed on more than one occasion. Only 24% were satisfactorily controlled at their first assessment, but this proportion had risen to 60% after 12 months. The ability of patients to perform unsupervised blood glucose levels using Ames Glucometers or BM-Glycemie 20-800 test strips was also assessed: 86% of the meter results were within one-third of the laboratory-based results, but there was evidence of bias towards the under-reading of higher glucose values using BM-Glycemie 20-800 test strips. Random blood glucose estimations performed in the diabetic clinic were of little value.
Assessment of three frequently used blood glucose monitoring devices in clinical routine.
Zueger, Thomas; Schuler, Vanessa; Stettler, Christoph; Diem, Peter; Christ, Emanuel R
2012-07-12
Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice. Capillary blood glucose was measured simultaneous using the following glucose meters: Contour® (Bayer Diabetes Care, Zürich, Switzerland), Accu-Chek® aviva (Roche Diagnostics, Rotkreuz, Switzerland), Free-Style® lite (Abbott Diabetes Care, Baar, Switzerland). The reference method consisted of the HemoCue® Glucose 201+ System (HemoCue® AB, Ängelholm, Sweden) with plasma conversion. The devices were assessed by comparison of the Mean Absolute Relative Differences (MARD), the Clarke Error Grid Analysis (EGA) and the compliance with the International Organization of Standardization criteria (ISO 15197:2003). Capillary blood samples were obtained from 150 patients. MARD was 10.1 ± 0.65%, 7.0 ± 0.62% and 7.8 ± 0.48% for Contour®, Accu-Chek® and Free-Style®, respectively. EGA showed 99.3% (Contour®), 98.7% (Accu-Chek®) and 100% (Free-Style®) of all measurements in zone A and B (clinically acceptable). The ISO criteria were fulfilled by Accu-Chek® (95.3%) and Free-Style® (96%), but not by Contour® (92%). In the present study the three glucose meters provided good agreement with the reference and reliable results in daily clinical routine. Overall, the Free-Style® and Accu-Chek® device slightly outperformed the Contour® device.
Assessment of anaerobic blood cultures in pediatric oncology patients.
Monsonís Cabedo, Manuel; Rives Solá, Susana; Noguera-Julian, Antoni; Urrea Ayala, Mireia; Cruz Martinez, Ofelia; Gené Giralt, Amadeu
2017-01-01
The routine use of a single aerobic bottle for blood culture in pediatric patients has become commonplace, as anaerobic bacteria are not frequently involved in clinically significant infections. The aim of this study was to assess the usefulness of routinely performing anaerobic blood cultures in pediatric oncology patients. Prospective study was conducted on pediatric (<18 years) patients affected with febrile syndrome after receiving chemotherapy for hematological or solid malignancies. Samples were inoculated into pediatric aerobic and standard anaerobic bottles (BacT/Alert automatic system). Strains were considered clinically significant, or deemed as contaminants, depending on isolation circumstances and clinical criteria. A total of 876 blood cultures from 228 patients were processed during the 21-month study period (January 2014 to September 2015). Baseline diagnosis included 143 solid tumors and 67/18 cases of leukemia/lymphoma. Bacterial growth was detected in 90 (10.2%) blood cultures for 95 different isolates, of which 62 (7.1%)/63 isolates were considered clinically significant. Among the latter, 38 (60.3%) microorganisms grew in both aerobic and anaerobic bottles, 18 (28.6%) only in aerobic bottles, and 7 (11.1%) only in anaerobic bottles. Gram-negative bacilli (33; 52.4%), mainly from the Enterobacteriaceae family, were the most frequently isolated microorganisms. Overall, only 3 out of 90 isolates (3.3%) were strict anaerobes (Propionibacterium acnes), and all of them were deemed contaminants. Strict anaerobes did not cause significant infections in febrile pediatric oncology patients, and anaerobic blood culture bottles offered no additional advantages over aerobic media. Our results suggest that routine blood cultures should be solely processed in aerobic media in this group of patients. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Godin, Simon; Bouzas-Ramos, Diego; Fontagné-Dicharry, Stéphanie; Bouyssière, Brice; Bueno, Maïté
2017-08-01
Studies have shown that information related to the presence of low-molecular-weight metabolites is frequently lost after deproteinization of complex matrices, such as blood and plasma, during sample preparation. Therefore, the effect of several deproteinization reagents on low-molecular-weight selenium species has been compared by species-specific isotope labeling. Two isotopically enriched selenium tracers were used to mimic models of small inorganic anionic ( 77 Se-selenite) and organic zwitterionic ( 76 Se-selenomethionine) species. The results presented here show that the use of a methanol-acetonitrile-acetone (1:1:1 v/v/v) mixture provided approximately two times less tracer loss from plasma samples in comparison with the classic procedure using acetonitrile, which may not be optimal as it leads to important losses of low-molecular-weight selenium species. In addition, the possible interactions between selenium tracers and proteins were investigated, revealing that both coprecipitation phenomena and association with proteins were potentially responsible for selenite tracer losses during protein precipitation in blood samples. However, coprecipitation phenomena were found to be fully responsible for losses of both tracers observed in plasma samples and of the selenomethionine tracer in blood samples. This successfully applied strategy is anticipated to be useful for more extensive future studies in selenometabolomics. Copyright © 2017 Elsevier Inc. All rights reserved.
Iron deficiency in blood donors: the REDS-II Donor Iron Status Evaluation (RISE) study.
Cable, Ritchard G; Glynn, Simone A; Kiss, Joseph E; Mast, Alan E; Steele, Whitney R; Murphy, Edward L; Wright, David J; Sacher, Ronald A; Gottschall, Jerry L; Tobler, Leslie H; Simon, Toby L
2012-04-01
Blood donors are at risk of iron deficiency. We evaluated the effects of blood donation intensity on iron and hemoglobin (Hb) in a prospective study. Four cohorts of frequent and first-time or reactivated (FT/RA) blood donors (no donation in 2 years), female and male, totaling 2425, were characterized and followed as they donated blood frequently. At enrollment and the final visit, ferritin, soluble transferrin receptor (sTfR), and Hb were determined. Models to predict iron deficiency and Hb deferral were developed. Iron depletion was defined at two levels: iron deficiency erythropoiesis (IDE) [log(sTfR/ferritin) ≥ 2.07] and absent iron stores (AIS; ferritin < 12 ng/mL). Among returning female FT and RA donors, 20 and 51% had AIS and IDE at their final visit, respectively; corresponding proportions for males were 8 and 20%. Among female frequent donors who returned, 27 and 62% had AIS and IDE, respectively, while corresponding proportions for males were 18 and 47%. Predictors of IDE and/or AIS included a higher frequency of blood donation in the past 2 years, a shorter interdonation interval, and being female and young; conversely, taking iron supplements reduced the risk of iron depletion. Predictors of Hb deferral included female sex, black race, and a shorter interdonation interval. There is a high prevalence of iron depletion in frequent blood donors. Increasing the interdonation interval would reduce the prevalence of iron depletion and Hb deferral. Alternatively, replacement with iron supplements may allow frequent donation without the adverse outcome of iron depletion. © 2011 American Association of Blood Banks.
Makroo, Raj Nath; Bhatia, Aakanksha; Hegde, Vikas; Chowdhry, Mohit; Thakur, Uday Kumar; Rosamma, N L
2014-09-01
The development of alloantibodies can significantly complicate transfusion therapy and results in difficulties in cross-matching of blood. Most literature on alloimmunization is limited to multitransfused individuals, with very few studies on the general hospital patients. This study was aimed at assessing the frequency and type of unexpected red cell antibodies in the general patient population at a multispecialty tertiary care centre in New Delhi, India. The results of 49,077 antibody screening tests carried out on patients, from January 2009 to December 2012 were analyzed. The clinical and transfusion records were reviewed. The data were compiled and statistically analysed. A total of 49,077 (29,917; 60.96% males and 19,160; 39.04% females) patient samples were screened for the presence of unexpected antibodies. Antibody screening was positive in 403 patients (0.82%). In the serum samples of 164 patients only autoantibodies were identified, 27 revealed autoantibodies with one or more underlying alloantibodies, while 212 patients had only alloantibody/ies in their serum. The overall alloimmunization rate was 0.49 per cent. Antibodies against the Rh system were the most frequent (64.1%), the most common alloantibody identified being anti E (37.2%), followed by anti D (19.2%). Since clinically significant antibodies are frequently detected in our patient population, antibody screening and if required, identification is the need of the hour. Since antibodies against the common Rh and Kell blood group antigens are the most frequent, provision of Rh and Kell matched red cells may be of protective value.
Tale of two sites: capillary versus arterial blood glucose testing in the operating room.
Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O
2012-04-01
Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a strong positive correlation of .91 between capillary glucose values and arterial values (P < .001) although correlation was less stringent at the hyperglycemic range of values. The R(2) statistic was 84%. Differences in values between capillary and arterial samples would not have altered the diagnosis of hypo- and hyperglycemia using typical thresholds. Capillary samples collected intraoperatively are strongly correlated with arterial samples. Glucose monitoring in the operating room can be safely performed by collecting capillary samples for POCT. However, clinicians should still be cautious when interpreting glucose levels that are high, either by repeating the blood glucose test or by having samples sent to the laboratory. Copyright © 2012 Elsevier Inc. All rights reserved.
Feasibility of a handheld near infrared device for the qualitative analysis of bloodstains.
Morillas, Alvaro Varela; Gooch, James; Frascione, Nunzianda
2018-07-01
One of the most common tasks in criminal investigation is to determine from which tissue source a biological fluid stain originates. As a result, there are many tests that are frequently used to determine if a stain is blood, semen or saliva by exploiting the properties of certain molecules present within the fluids themselves. These include chemical reagents such as the Kastle-Meyer or Acid Phosphatase tests, as well as other techniques like the use of alternative light sources. However, most of the tests currently available have some major drawbacks. In this study, a handheld near-infrared spectrometer is investigated for the specific identification of deposited bloodstains. First, a calibration was carried out by scanning over 500 positive (blood present) and negative (blood absent) samples to train several predictive models based on machine learning principles. These models were then tested on over 100 new positive and negative samples to evaluate their performance. All models tested were able to correctly classify deposited stains as blood in at least 81% of tested samples, with some models allowing for even higher classification accuracy at over 94%. This suggests that handheld near infrared devices could offer great opportunity for the rapid, low cost and non-destructive screening of body fluids at scenes of crime. Copyright © 2018 Elsevier B.V. All rights reserved.
Tomiyama, A. Janet; O’Donovan, Aoife; Lin, Jue; Puterman, Eli; Lazaro, Alanie; Chan, Jessica; Dhabhar, Firdaus S.; Wolkowitz, Owen; Kirschbaum, Clemens; Blackburn, Elizabeth; Epel, Elissa
2012-01-01
Long-term exposure to stress and its physiological mediators, in particular cortisol, may lead to impaired telomere maintenance. In this study, we examine if greater cortisol responses to an acute stressor and/or dysregulated patterns of daily cortisol secretion are associated with shorter telomere length. Twenty-three post-menopausal women comprising caregivers for dementia partners (n=14) and age- and BMI-matched non-caregivers provided home sampling of cortisol–saliva samples at waking, 30 min after waking, and bedtime, and a 12-hour overnight urine collection. They were also exposed to an acute laboratory stressor throughout which they provided saliva samples. Peripheral blood mononuclear cells were isolated from a fasting blood sample and assayed for telomere length. As hypothesized, greater cortisol responses to the acute stressor were associated with shorter telomeres, as were higher overnight urinary free cortisol levels and flatter daytime cortisol slopes. While robust physiological responses to acute stress serve important functions, the long-term consequences of frequent high stress reactivity may include accelerated telomere shortening. PMID:22138440
Goodman, Heather; Egizi, Andrea; Fonseca, Dina M; Leisnham, Paul T; LaDeau, Shannon L
2018-04-10
Temperate urban landscapes support persistent and growing populations of Culex and Aedes mosquito vectors. Large urban mosquito populations can represent a significant risk for transmission of emergent arboviral infection. However, even large mosquito populations are only a risk to the animals they bite. The purpose of this study is to identify and assess spatial patterns of host-use in a temperate urban landscape with heterogeneous socio-economic and ecological conditions. Mosquito blood meals were collected from neighborhoods categorized along a socio-economic gradient in Baltimore, MD, USA. Blood meal hosts were identified for two Aedes (Ae. albopictus and Ae. japonicus) and three Culex (Cx. pipiens, Cx. restuans and Cx. salinarius) species. The brown rat (Rattus norvegicus) was the most frequently detected host in both Aedes species and Cx. salinarius. Human biting was evident in Aedes and Culex species and the proportion of human blood meals from Ae. albopictus varied significantly with neighborhood socio-economic status. Aedes albopictus was most likely to feed on human blood hosts (at 50%) in residential blocks categorized as having income above the city median, although there were still more total human bites detected from lower income blocks where Ae. albopictus was more abundant. Birds were the most frequently detected Culex blood hosts but were absent from all Aedes sampled. This study highlights fine-scale variation in host-use by medically important mosquito vectors and specifically investigates blood meal composition at spatial scales relevant to urban mosquito dispersal and human exposure. Further, the work emphasizes the importance of neighborhood economics and infrastructure management in shaping both the relative abundance of vectors and local blood feeding strategies. The invasive brown rat was an important blood source across vector species and neighborhoods in Baltimore. We show that social and economic conditions can be important predictors of transmission potential in urban landscapes and identify important questions about the role of rodents in supporting urban mosquito populations.
Genomic expression patterns in medication overuse headaches
Hershey, Andrew D; Burdine, Danny; Kabbouche, Marielle A; Powers, Scott W
2016-01-01
Background Chronic daily headache (CDH) and chronic migraine (CM) are one of the most frequent problems encountered in neurology, are often difficult to treat, and frequently complicated by medication-overuse headache (MOH). Proper recognition of MOH may alter treatment outcome and prevent long term disability. Objective This study identifies the unique genomic expression pattern MOH that respond to cessation of the overused medication. Methods Baseline occurrence of MOH and typical pattern of response to medication cessation were measured from a large database. Whole blood samples from patients with CM with or without MOH were obtained and their genomic profile was assessed. Affymetrix human U133 plus2 arrays were used to examine the genomic expression patterns prior to treatment and 6–12 weeks later. Headache characterisation and response to treatment based on headache frequency and disability were compared. Results Of 1311 patients reporting daily or continuous headaches, 513 (39.1%) reported overusing analgesic medication. At follow-up, 44.5% had a 50% or greater reduction in headache frequency, while 41.6% had no change. Blood genomic expression patterns were obtained on 33 patients with 19 (57.6%) overusing analgesic medication with a unique genomic expression pattern in MOH that responded to cessation of analgesics. Gene ontology of these samples indicated a significant number were involved with brain and immunological tissues, including multiple signalling pathways and apoptosis. Conclusions Blood genomic patterns can accurately identify MOH patients that respond to medication cessation. These results suggest that MOH involves a unique molecular biology pathway that can be identified with a specific biomarker. PMID:20974594
Lorusso, Alessio; Baba, Doumbia; Spedicato, Massimo; Teodori, Liana; Bonfini, Barbara; Marcacci, Maurilia; Di Provvido, Andrea; Isselmou, Katia; Marini, Valeria; Carmine, Irene; Scacchia, Massimo; Di Sabatino, Daria; Petrini, Antonio; Bezeid, Beyatt Ahmed; Savini, Giovanni
2016-06-01
In March 2013, EDTA-blood and serum samples were collected from 119 cattle and 159 dromedaries at the slaughterhouse of Nouakchott, the capital city of the Islamic Republic of Mauritania. Serum samples were screened for the presence of Bluetongue (BT) antibodies by competitive ELISA (cELISA). Positive samples were then tested by serum-neutralization (SN) to determine BTV serotype. RNA from blood samples was first tested by a genus-specific quantitative RT-PCR assay which is able to detect all 27 existing BTV serotypes (RT-qPCR1-27). Positive samples were further screened by a RT-qPCR assay which, instead, is able to detect the classical 24 BTV serotypes only (RT-qPCR1-24). Of the 278 serum samples tested, 177 (mean=63.7%; 95% CI: 57.9%-69.1%) resulted positive by cELISA. Of these, 69 were from cattle (mean=58.0%; 95% CI: 49.0%-66.5%) and 108 from dromedaries (mean=67.9%; 95% CI: 60.3%-74.7%). BTV-26 neutralizing antibodies were by far the most frequently found as they were detected in 146 animals with titres ranging from 1:10 to 1:80. Out of 278 blood samples, 25 (mean=9.0%; 95% CI: 6.2%-12.9%) were found positive for BTV by RT-qPCR1-27, 20 (mean=16.8%; 95% CI: 11.2%-24.6%) were from cattle and 5 (mean=3.1%; 95% CI: 1.4%-7.1%) from dromedaries. When tested by RT-qPCR1-24 the 25 BTV positive samples were negative. Unfortunately, no genetic information by molecular typing or by next generation sequencing has been obtained as for the very low levels of RNA in the blood samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Molecular Subtyping of Treponema pallidum subsp. pallidum in Lisbon, Portugal▿
Castro, R.; Prieto, E.; Águas, M. J.; Manata, M. J.; Botas, J.; Martins Pereira, F.
2009-01-01
The objectives of this study were to evaluate the reproducibility of a molecular method for the subtyping of Treponema pallidum subsp. pallidum and to discriminate strains of this microorganism from strains from patients with syphilis. We studied 212 specimens from a total of 82 patients with different stages of syphilis (14 primary, 7 secondary and 61 latent syphilis). The specimens were distributed as follows: genital ulcers (n = 9), skin and mucosal lesions (n = 7), blood (n = 82), plasma (n = 82), and ear lobe scrapings (n = 32). The samples were assayed by a PCR technique to amplify a segment of the polymerase gene I (polA). Positive samples were typed on the basis of the analysis of two variable genes, tpr and arp. Sixty-two of the 90 samples positive for polA yielded typeable Treponema pallidum DNA. All skin lesions in which T. pallidum was identified (six of six [100%]) were found to contain enough DNA for typing of the organism. It was also possible to type DNA from 7/9 (77.7%) genital ulcer samples, 13/22 (59.1%) blood samples, 20/32 (62.5%) plasma samples, and 16/21 (76.2%) ear lobe scrapings. The same subtype was identified in all samples from the same patient. Five molecular subtypes (subtypes 10a, 14a, 14c, 14f, and 14g) were identified, with the most frequently found subtype being subtype 14a and the least frequently found subtype being subtype 10a. In conclusion, the subtyping technique used in this study seems to have good reproducibility. To our knowledge, subtype 10a was identified for the first time. Further studies are needed to explain the presence of this subtype in Portugal, namely, its relationship to the Treponema pallidum strains circulating in the African countries where Portuguese is spoken. PMID:19494073
Specimen rejection in laboratory medicine: Necessary for patient safety?
Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz
2015-01-01
Introduction The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. Materials and methods The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Results Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. Conclusions We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety. PMID:26527231
M'ghirbi, Y; Hurtado, A; Barandika, J F; Brandika, J; Khlif, K; Ketata, Z; Bouattour, A
2008-07-01
Between October and November 2006, a total of 278 bovine blood samples were examined, and 104 (37.4%) were positive for piroplasms by microscopy. A reverse line blot hybridisation with polymerase chain reaction detected Theileria annulata, T. buffeli, Babesia bovis and B. bigemina in cattle accounting for 48.6% of positive samples. The most frequently found species was T. buffeli, which was present in 39.2% of the samples. T. annulata was found in 48 samples (17.3%). Babesia infections were less frequently detected: B. bovis was found in 6.8% of the samples and B. bigemina in 4.3%. Mixed infections were detected in 45 samples, accounting for seven different combinations of species. Seven Ixodid tick species (Boophilus annulatus, Ixodes ricinus, Hyalomma marginatum, Hyalomma excavatum, Hyalomma detritum, Haemaphysalis punctata and Haemaphysalis sulcata) were collected from examined cattle in the 23 visited farms. I. ricinus was the dominant species (36%), mainly collected in the humid zone, while it seemed to be very rare in the semi-arid zone (where only 15 specimens were collected), whereas B. annulatus was the most commonly collected species in the sub-humid area (68.5% of ticks collected in this zone).
Aagaard, Sissel Kramer; Larsen, Agnete; Andreasen, Mette Findal; Lesnikova, Iana; Telving, Rasmus; Vestergaard, Anna Louise; Tørring, Niels; Uldbjerg, Niels; Bor, Pinar
2018-03-03
The aim of this study was to investigate the prevalence of xenobiotic substances, such as caffeine, nicotine and illicit drugs (eg, cannabis and cocaine), in blood samples from first-trimester Danish pregnant women unaware of the screening. A cross - sectional study examined 436 anonymised residual blood samples obtained during 2014 as part of the nationwide prenatal first-trimester screening programme. The samples were analysed by ultra performance liquid chromatography with high-resolution time-of-flight mass spectrometry. An antenatal clinic in a Danish city with 62 000 inhabitants, where >95% of pregnant women joined the screening programme. The prevalence and patterns of caffeine, nicotine, medication and illicit drug intake during the first trimester of pregnancy. The prevalence of prescription and over-the-counter drug detection was 17.9%, including acetaminophen (8.9%) and antidepressants (3.0%), of which citalopram (0.9%) was the most frequent. The prevalence of illegal drugs, indicators of smoking (nicotine/cotinine) and caffeine was 0.9%, 9.9%, and 76.4%, respectively. Only 17.4% of women had no substance identified in their sample. This study emphasises the need for further translational studies investigating lifestyle habits during pregnancy, as well as the underlying molecular mechanisms through which xenobiotic substances may affect placental function and fetal development. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Nuckols, John R; Ashley, David L; Lyu, Christopher; Gordon, Sydney M; Hinckley, Alison F; Singer, Philip
2005-07-01
Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre-water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and post-activity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities.
Nuckols, John R.; Ashley, David L.; Lyu, Christopher; Gordon, Sydney M.; Hinckley, Alison F.; Singer, Philip
2005-01-01
Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre–water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and postactivity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities. PMID:16002374
Safe fetal platelet genotyping: new developments.
Le Toriellec, Emilie; Chenet, Christophe; Kaplan, Cecile
2013-08-01
Fetal and neonatal alloimmune thrombocytopenia (FNAIT) is due to maternal alloimmunization against fetal platelet (PLT) antigens. Antenatal management strategies have been developed to avoid complications such as intracranial hemorrhage. The aim of this study was to set up two reliable, noninvasive fetal genotyping assays to determine the fetal risk in pregnancies in which the father is heterozygous for the offending antigen. This study focused on human PLT antigen (HPA)-1, the most frequently implicated antigen in FNAIT in Caucasians. Two assays based on cell-free fetal DNA extracted from maternal blood samples and on real-time polymerase chain reaction (QPCR) were developed: an allele-specific QPCR specifically targeting the polymorphic sequence in HPA-1 and the study of the variation in the high-resolution melting curve of amplicons containing the polymorphic region. All results from the 49 samples obtained from 29 pregnant women were consistent with expectations. Six women were compatible with their fetuses (three HPA-1aa women and three HPA-1bb women), 41 HPA-1bb women were incompatible with their fetuses, as were two HPA-1aa women. Two fetal PLT genotyping assays on maternal blood samples proved to be reliable as of 15 weeks of gestation, thereby avoiding invasive techniques such as amniocentesis. © 2012 American Association of Blood Banks.
Robert-Gangneux, Florence; Sterkers, Yvon; Yera, Hélène; Accoceberry, Isabelle; Menotti, Jean; Cassaing, Sophie; Brenier-Pinchart, Marie-Pierre; Hennequin, Christophe; Delhaes, Laurence; Bonhomme, Julie; Villena, Isabelle; Scherer, Emeline; Dalle, Frédéric; Touafek, Feriel; Filisetti, Denis; Varlet-Marie, Emmanuelle; Pelloux, Hervé; Bastien, Patrick
2015-05-01
Toxoplasmosis is a life-threatening infection in immunocompromised patients (ICPs). The definitive diagnosis relies on parasite DNA detection, but little is known about the incidence and burden of disease in HIV-negative patients. A 3-year retrospective study was conducted in 15 reference laboratories from the network of the French National Reference Center for Toxoplasmosis, in order to record the frequency of Toxoplasma gondii DNA detection in ICPs and to review the molecular methods used for diagnosis and the prevention measures implemented in transplant patients. During the study period, of 31,640 PCRs performed on samples from ICPs, 610 were positive (323 patients). Blood (n = 337 samples), cerebrospinal fluid (n = 101 samples), and aqueous humor (n = 100 samples) were more frequently positive. Chemoprophylaxis schemes in transplant patients differed between centers. PCR follow-up of allogeneic hematopoietic stem cell transplant (allo-HSCT) patients was implemented in 8/15 centers. Data from 180 patients (13 centers) were further analyzed regarding clinical setting and outcome. Only 68/180 (38%) patients were HIV(+); the remaining 62% consisted of 72 HSCT, 14 solid organ transplant, and 26 miscellaneous immunodeficiency patients. Cerebral toxoplasmosis and disseminated toxoplasmosis were most frequently observed in HIV and transplant patients, respectively. Of 72 allo-HSCT patients with a positive PCR result, 23 were asymptomatic; all were diagnosed in centers performing systematic blood PCR follow-up, and they received specific treatment. Overall survival of allo-HSCT patients at 2 months was better in centers with PCR follow-up than in other centers (P < 0.01). This study provides updated data on the frequency of toxoplasmosis in HIV-negative ICPs and suggests that regular PCR follow-up of allo-HSCT patients could guide preemptive treatment and improve outcome. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Sterkers, Yvon; Yera, Hélène; Accoceberry, Isabelle; Menotti, Jean; Cassaing, Sophie; Brenier-Pinchart, Marie-Pierre; Hennequin, Christophe; Delhaes, Laurence; Bonhomme, Julie; Villena, Isabelle; Scherer, Emeline; Dalle, Frédéric; Touafek, Feriel; Filisetti, Denis; Varlet-Marie, Emmanuelle; Pelloux, Hervé; Bastien, Patrick
2015-01-01
Toxoplasmosis is a life-threatening infection in immunocompromised patients (ICPs). The definitive diagnosis relies on parasite DNA detection, but little is known about the incidence and burden of disease in HIV-negative patients. A 3-year retrospective study was conducted in 15 reference laboratories from the network of the French National Reference Center for Toxoplasmosis, in order to record the frequency of Toxoplasma gondii DNA detection in ICPs and to review the molecular methods used for diagnosis and the prevention measures implemented in transplant patients. During the study period, of 31,640 PCRs performed on samples from ICPs, 610 were positive (323 patients). Blood (n = 337 samples), cerebrospinal fluid (n = 101 samples), and aqueous humor (n = 100 samples) were more frequently positive. Chemoprophylaxis schemes in transplant patients differed between centers. PCR follow-up of allogeneic hematopoietic stem cell transplant (allo-HSCT) patients was implemented in 8/15 centers. Data from 180 patients (13 centers) were further analyzed regarding clinical setting and outcome. Only 68/180 (38%) patients were HIV+; the remaining 62% consisted of 72 HSCT, 14 solid organ transplant, and 26 miscellaneous immunodeficiency patients. Cerebral toxoplasmosis and disseminated toxoplasmosis were most frequently observed in HIV and transplant patients, respectively. Of 72 allo-HSCT patients with a positive PCR result, 23 were asymptomatic; all were diagnosed in centers performing systematic blood PCR follow-up, and they received specific treatment. Overall survival of allo-HSCT patients at 2 months was better in centers with PCR follow-up than in other centers (P < 0.01). This study provides updated data on the frequency of toxoplasmosis in HIV-negative ICPs and suggests that regular PCR follow-up of allo-HSCT patients could guide preemptive treatment and improve outcome. PMID:25762774
Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples
Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely
2008-01-01
Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170
NASA Astrophysics Data System (ADS)
Pachaiappan, Rekha; Prakasarao, Aruna; Singaravelu, Ganesan
2017-02-01
Oral cancer is the most frequent type of cancer that occurs with 75000 to 80000 new cases reported every year in India. The carcinogens from tobacco and related products are the main cause for the oral cancer. ATR-FTIR method is label free, fast and cost-effective diagnostic method would allow for rapid diagnostic results in earlier stages by the minimal chemical changes occur in the biological metabolites available in the blood plasma. The present study reports the use of ATR-FTIR data with advanced statistical model (LDA-ANN) in the diagnosis of oral cancer from normal with better accuracy. The infrared spectra were acquired on ATR-FTIR Jasco spectrophotometer at 4 cm-1 resolution, 30 scans, in the 1800-900 cm-1 spectral range. Each sample had 5 spectra recorded from each blood plasma sample. The spectral data were routed through the multilayer perception of artificial neural network to evaluate for the statistical efficacy. Among the spectral data it was found that amide II (1486 cm-1) and lipid (1526 cm-1) affords about 90 % in the discrimination between groups using LDA. These preliminary results indicate that ATR-FTIR is useful to differentiate normal subject from oral cancer patients using blood plasma.
Prieto, J; García-Rodríguez, Ja; Barberán, J; Granizo, Jj; Rodicio, Mp; González, J
2008-12-01
The laboratory is an essential part of the work in the Clinical Microbiology Department. This study has aimed to measure the activity of these laboratories. A survey was self-administered on the activity occurring during one work day by each hospital in October 2007. Thirty six hospitals reported 14,076 tests. Serology was the most frequently reported test (30.3%) followed by urine culture (27.8 %), blood tests (13.2 %), respiratory tract samples (8%), feces (7.1%), urethral (5.8%), skin (5.3%) and cerebrospinal fluid (2.6%). According to species, 73.2% of the isolates were bacteria (22.9 % were positive), 8.9% were virus (17% positive), fungi 8.1% (25.2% positive), and 5.5% mycobacterias (5.9% were positive) and parasite 4.5% (12.5% positive). Susceptibility test were performed by automatic methods (62.3%) followed by diffusion test (27.1%) and E-test (9.1%). A total of 5.6% of the susceptibility tests showed in vitro resistance to antibiotics. Fungi were identified in 108 isolates. Candida and Aspergillus were the most frequent genus (85.1% and 8.3%, respectively). Origins of the samples were: lower respiratory tract (32.4 %), genital tract (24.1 %), urine (10.2 %), blood (10.2 %) and skin (10.2 %). Twelve identification techniques were used, the most frequent being the morphological test (54.8%) and biochemical test (39.7%). Broken down by departments, 20.4% were sent from the ICU, 16.7% from surgery, 29.6% from medicine and 18.5% from primary care. Although the workload of the laboratories has been measured in this work, aspects such as specimen manipulation, clinical advice and research were not considered.
Bıçakçı, Zafer; Olcay, Lale
2014-06-01
Metabolic alkalosis, which is a non-massive blood transfusion complication, is not reported in the literature although metabolic alkalosis dependent on citrate metabolism is reported to be a massive blood transfusion complication. The aim of this study was to investigate the effect of elevated carbon dioxide production due to citrate metabolism and serum electrolyte imbalance in patients who received frequent non-massive blood transfusions. Fifteen inpatients who were diagnosed with different conditions and who received frequent blood transfusions (10-30 ml/kg/day) were prospectively evaluated. Patients who had initial metabolic alkalosis (bicarbonate>26 mmol/l), who needed at least one intensive blood transfusion in one-to-three days for a period of at least 15 days, and whose total transfusion amount did not fit the massive blood transfusion definition (<80 ml/kg) were included in the study. The estimated mean total citrate administered via blood and blood products was calculated as 43.2 ± 34.19 mg/kg/day (a total of 647.70 mg/kg in 15 days). Decompensated metabolic alkalosis+respiratory acidosis developed as a result of citrate metabolism. There was a positive correlation between cumulative amount of citrate and the use of fresh frozen plasma, venous blood pH, ionized calcium, serum-blood gas sodium and mortality, whereas there was a negative correlation between cumulative amount of citrate and serum calcium levels, serum phosphorus levels and amount of urine chloride. In non-massive, but frequent blood transfusions, elevated carbon dioxide production due to citrate metabolism causes intracellular acidosis. As a result of intracellular acidosis compensation, decompensated metabolic alkalosis+respiratory acidosis and electrolyte imbalance may develop. This situation may contribute to the increase in mortality. In conclusion, it should be noted that non-massive, but frequent blood transfusions may result in certain complications. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mohseni, Michael; Silvers, Scott; McNeil, Rebecca; Diehl, Nancy; Vadeboncoeur, Tyler; Taylor, Walt; Shapiro, Shane; Roth, Jennifer; Mahoney, Sherry
2011-01-01
Background: Prior reports on metabolic derangements observed in distance running frequently have small sample sizes, lack prerace laboratory measures, and report sodium as the sole measure. Hypothesis: Metabolic abnormalities—hyponatremia, hypokalemia, renal dysfunction, hemoconcentration—are frequent after completing a full or half marathon. Clinically significant changes occur in these laboratory values after race completion. Study Design: Observational, cross-sectional study. Methods: Consenting marathon and half marathon racers completed a survey as well as finger stick blood sampling on race day of the National Marathon to Fight Breast Cancer (Jacksonville, Florida, February 2008). Parallel blood measures were obtained before and after race completion (prerace, n = 161; postrace, n = 195). Results: The prevalence of prerace and postrace hyponatremia was 8 of 161 (5.0%) and 16 of 195 (8.2%), respectively. Hypokalemia was not present prerace but was present in 1 runner postrace (1 of 195). Renal dysfunction occurred prerace in 14 of 161 (8.7%) and postrace in 83 of 195 (42.6%). Among those with postrace renal dysfunction, 45.8% (38 of 83) were classified as moderate or severe. Hemoconcentration was present in 2 of 161 (1.2%) prerace and 6 of 195 (3.1%) postrace. The mean changes in laboratory values were (postrace minus prerace): sodium, 1.6 mmol/L; potassium, −0.2 mmol/L; blood urea nitrogen, 2.8 mg/dL; creatinine, 0.2 mg/dL; and hemoglobin, 0.3 g/dL for 149 pairs (except blood urea nitrogen, n = 147 pairs). Changes were significant for all comparisons (P < 0.01) except potassium (P = 0.08) and hemoglobin (P = 0.01). Conclusions: Metabolic abnormalities are common among endurance racers, and they may be present prerace, including hyponatremia. The clinical significance of these findings is unknown. Clinical relevance: It is unclear which runners are at risk for developing clinically important metabolic derangements. Participating in prolonged endurance exercise appears to be safe in the majority of racers. PMID:23016001
DYZ1 arrays show sequence variation between the monozygotic males
2014-01-01
Background Monozygotic twins (MZT) are an important resource for genetical studies in the context of normal and diseased genomes. In the present study we used DYZ1, a satellite fraction present in the form of tandem arrays on the long arm of the human Y chromosome, as a tool to uncover sequence variations between the monozygotic males. Results We detected copy number variation, frequent insertions and deletions within the sequences of DYZ1 arrays amongst all the three sets of twins used in the present study. MZT1b showed loss of 35 bp compared to that in 1a, whereas 2a showed loss of 31 bp compared to that in 2b. Similarly, 3b showed 10 bp insertion compared to that in 3a. MZT1a germline DNA showed loss of 5 bp and 1b blood DNA showed loss of 26 bp compared to that of 1a blood and 1b germline DNA, respectively. Of the 69 restriction sites detected in DYZ1 arrays, MboII, BsrI, TspEI and TaqI enzymes showed frequent loss and or gain amongst all the 3 pairs studied. MZT1 pair showed loss/gain of VspI, BsrDI, AgsI, PleI, TspDTI, TspEI, TfiI and TaqI restriction sites in both blood and germline DNA. All the three sets of MZT showed differences in the number of DYZ1 copies. FISH signals reflected somatic mosaicism of the DYZ1 copies across the cells. Conclusions DYZ1 showed both sequence and copy number variation between the MZT males. Sequence variation was also noticed between germline and blood DNA samples of the same individual as we observed at least in one set of sample. The result suggests that DYZ1 faithfully records all the genetical changes occurring after the twining which may be ascribed to the environmental factors. PMID:24495361
A Bayesian network for modelling blood glucose concentration and exercise in type 1 diabetes.
Ewings, Sean M; Sahu, Sujit K; Valletta, John J; Byrne, Christopher D; Chipperfield, Andrew J
2015-06-01
This article presents a new statistical approach to analysing the effects of everyday physical activity on blood glucose concentration in people with type 1 diabetes. A physiologically based model of blood glucose dynamics is developed to cope with frequently sampled data on food, insulin and habitual physical activity; the model is then converted to a Bayesian network to account for measurement error and variability in the physiological processes. A simulation study is conducted to determine the feasibility of using Markov chain Monte Carlo methods for simultaneous estimation of all model parameters and prediction of blood glucose concentration. Although there are problems with parameter identification in a minority of cases, most parameters can be estimated without bias. Predictive performance is unaffected by parameter misspecification and is insensitive to misleading prior distributions. This article highlights important practical and theoretical issues not previously addressed in the quest for an artificial pancreas as treatment for type 1 diabetes. The proposed methods represent a new paradigm for analysis of deterministic mathematical models of blood glucose concentration. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Broad-Range 16S rDNA PCR on Heart Valves in Infective Endocarditis.
Müller Premru, Manica; Lejko Zupanc, Tatjana; Klokočovnik, Tomislav; Ruzić Sabljić, Eva; Cerar, Tjaša
2016-03-01
Infective endocarditis (IE) is diagnosed by blood and/or resected valve cultivation and echocardiographic findings, as defined by the Duke criteria. Unfortunately, cultures may be negative due to prior antibiotic therapy or fastidious or slow-growing microorganisms. The study aim was to investigate the value of the broad-range polymerase chain reaction (PCR) in addition to blood and valve culture for the detection of causative microorganisms. Between February 2012 and March 2015, valve samples from 36 patients undergoing cardiac surgery were analyzed; of these patients, 26 had a preoperative diagnosis of IE and 10 served as controls. Multiple blood cultures were obtained from 34 patients before antibiotic therapy was commenced. Valve samples were inoculated on bacteriological media and underwent analysis using broad-range PCR (16S rDNA). IE was confirmed microbiologically in 21 of the 26 patients (80.7%); in 20 cases (76.9%) this was by positive blood cultures and in 16 (61.5%) by positive valves. Valves were positive in 15 blood culturepositive patients, and in one blood-culture negative patient. Broad-range PCR detected a microorganism in valves significantly more frequently (n = 14; 53.8%) compared to valve culture (n = 8; 30.7%) (chisquare 11.5, p <0.001). The predominant microorganisms were Staphylococcus aureus, Streptococcus of the viridans group, coagulasenegative staphylococci and Enterococcus faecalis. Blood, valve cultures and broad-range PCR were negative in five patients (19.3%) with IE, and in all 10 subjects of the control group. Broad-range PCR on valves was more sensitive than valve culture. However, blood culture, if taken before the start of antibiotic therapy, was the best method for detecting IE.
Human skin volatiles: a review.
Dormont, Laurent; Bessière, Jean-Marie; Cohuet, Anna
2013-05-01
Odors emitted by human skin are of great interest to biologists in many fields; applications range from forensic studies to diagnostic tools, the design of perfumes and deodorants, and the ecology of blood-sucking insect vectors of human disease. Numerous studies have investigated the chemical composition of skin odors, and various sampling methods have been used for this purpose. The literature shows that the chemical profile of skin volatiles varies greatly among studies, and the use of different sampling procedures is probably responsible for some of these variations. To our knowledge, this is the first review focused on human skin volatile compounds. We detail the different sampling techniques, each with its own set of advantages and disadvantages, which have been used for the collection of skin odors from different parts of the human body. We present the main skin volatile compounds found in these studies, with particular emphasis on the most frequently studied body regions, axillae, hands, and feet. We propose future directions for promising experimental studies on odors from human skin, particularly in relation to the chemical ecology of blood-sucking insects.
NASA Astrophysics Data System (ADS)
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Managing a Mycotic Thoracoabdominal Aneurysm: The Importance of Molecular Diagnostics.
Bayliss, Christopher D; Booth, Karen L; Williams, Robin; Dark, John H; Gould, Kate F
2017-11-01
Pneumococcal mycotic aneurysms are rare and associated with significant mortality and morbidity. Early intravenous antibiotic therapy and surgical intervention is the mainstay of treatment. Pneumococci frequently autolyze in blood cultures, making microbiological diagnosis challenging. We present the case of a man in his mid 70s with multiple thoracoabdominal mycotic aneurysms. Surgery was performed to a threatening saccular aortic arch aneurysm. Samples were sent for microbiological analysis and all were culture negative. The samples were then referred for bacterial 16S ribosomal RNA sequencing, which revealed evidence of infection with Streptococcus pneumoniae. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
[Detection frequency of haemoplasma infections of the domestic cat in Germany].
Just, Frankthomas; Pfister, Kurt
2007-01-01
We present epidemiological data on the frequency of infections with haemotrophic Mycoplasma spp. (feline haemoplasmas) in domestic cats in Germany. From November 2004 to October 2006 135 blood samples of anaemic patients and cats without clinical symptoms were examined with conventional and real-time PCR methods. In 15,6 % of the samples DNA of one or more haemoplasma species could be detected. 8,9 % of the samples (12 cats) were infected with "Candidatus Mycoplasma haemominutum, whereas 7,4 % (10 cats) were infected with Mycoplasma haemofelis. Out of these, one cat harboured both species. The recently described species "Candidatus Mycoplasma turicensis" was found in 2.2 % of all samples (3 cats) and was restricted to animals coinfected with M. haemofelis. No correlation could be detected between the infection with haemotrophic Mycoplasma spp. and clinical signs of anaemia or disease. Infections were significantly correlated with age, male gender or coinfections with retroviruses (FIV, FeLV). Our data indicate, that chronically infected carriers without clinical symptoms are frequent in the investigated cat populations in Germany and that the screening of blood-donors for the presence of Mycoplasma spp. infections is advisable before clinical use.
[Feline leukemia virus infection: importance and current situation in Switzerland].
Hofmann-Lehmann, R; Gönczi, E; Riond, B; Meli, M; Willi, B; Howard, J; Schaarschmidt-Kiener, D; Regli, W; Gilli, U; Boretti, F
2018-02-01
Feline leukemia virus (FeLV) leads to fatal disease in cats with progressive infection. The aim of this study was to determine the importance of FeLV infection in Switzerland and make a comparison with previous studies. Of 881 blood samples taken from cats living in Switzerland (minimum of 20 samples per Canton), 47 samples were provirus-positive (5.3%; 95% confidence interval (CI) 3.9-7.0%) and 18 samples were antigen-positive (2%; 95% CI 1.2-3.2%). Together with data previously collected in similar studies, these findings demonstrated a decrease in prevalence between 1997 and 2003 followed by a relative constant low prevalence thereafter. Young cats (=2 years) were more frequently infected than older cats, but FeLV-positive cats were up to 15 (antigen-positive) and 19 (provirus-positive) years old. Sexually intact cats were more frequently viremic than neutered cats; purebred cats were somewhat less frequently FeLV-positive than non-purebred cats. In a second study, in which 300 saliva samples were analyzed, samples from 5 cats were FeLV-RNA positive (1.7%; 95% CI, 0.5-3.8%), although one young feral cat had been falsely assumed to be FeLV-negative based on a point-of-care test. Of the 300 cats, only 50% were FeLV tested or vaccinated, although 90% of the cats were at risk of exposure to FeLV. Testing and vaccination of all cats with exposure risk may help further decrease the prevalence of FeLV infection. Moreover, characteristics of FeLV tests should be considered, such as the risk of false negative results in the early phase of infection when performing antigen testing.
Real-time monitoring of human blood clotting using a lateral excited film bulk acoustic resonator
NASA Astrophysics Data System (ADS)
Chen, Da; Wang, Jingjng; Wang, Peng; Guo, Qiuquan; Zhang, Zhen; Ma, Jilong
2017-04-01
Frequent assay of hemostatic status is an essential issue for the millions of patients using anticoagulant drugs. In this paper, we presented a micro-fabricated film bulk acoustic sensor for the real-time monitoring of blood clotting and the measurement of hemostatic parameters. The device was made of an Au/ZnO/Si3N4 film stack and excited by a lateral electric field. It operated under a shear mode resonance with the frequency of 1.42 GHz and had a quality factor of 342 in human blood. During the clotting process of blood, the resonant frequency decreased along with the change of blood viscosity and showed an apparent step-ladder curve, revealing the sequential clotting stages. An important hemostatic parameter, prothrombin time, was quantitatively determined from the frequency response for different dilutions of the blood samples. The effect of a typical anticoagulant drug (heparin) on the prothrombin time was exemplarily shown. The proposed sensor displayed a good consistency and clinical comparability with the standard coagulometric methods. Thanks to the availability of direct digital signals, excellent potentials of miniaturization and integration, the proposed sensor has promising application for point-of-care coagulation technologies.
[Blood safety: malaria and blood donation in Africa].
Tayou Tagny, C; Mbanya, D; Garraud, O; Lefrère, J-J
2007-11-01
Malaria is a principal cause of mortality in Africa and represents a major blood-borne disease. The studies made on the continent show that transfusion-associated malaria is highly prevalent in blood donors groups and that some risk factors and clinical manifestations are frequently observed. The disease is mostly asymptomatic and the signs are mild, which reduces significantly an efficient selection of the blood donors during the predonation interview and a secure supply of blood products. Furthermore, the lack of appropriate screening assays of the malaria in blood banks on the continent limit the diagnosis of the disease and hamper the blood safety. However, the prevention of transfusion-associated malaria is a frequently asked question. The destruction of the parasite in the blood bag and the recipient anti-malarial prophylaxis are the described possibilities, added to local programs against the vectors of the disease.
Schecter, Arnold; Colacino, Justin; Haffner, Darrah; Patel, Keyur; Opel, Matthias; Päpke, Olaf
2010-01-01
This paper presents new data on the levels of polybrominated diphenyl ethers (PBDEs) in American airline workers. This pilot study did not find elevated total PBDEs in the blood of nine flight attendants and one aircraft pilot who have worked in airplanes for at least the past 5 years. These findings are not consistent with the findings of elevated blood levels of PBDEs from the 2008 Christiansson et al. publication "Polybrominated diphenyl ethers in aircraft cabins - A source of human exposure?" We agree that more research needs to be done on larger, more representative samples of airline workers to better characterize exposure of airline workers and other frequent flyers to PBDEs.
Davids, Denver; Gibson, Diana; Johnson, Quinton
2016-12-24
The aim of this study was to identify and document medicinal plants used to manage High Blood Pressure and Type 2 Diabetes Mellitus in Bitterfontein, Western Cape Province, South Africa. One hundred and twelve (112) respondents were interviewed between August 2014 and September 2015 through semi-structured surveys to gather data on the percentage of people who had been diagnosed with High Blood Pressure and/or Type 2 Diabetes Mellitus and to determine the frequency of medicinal plant and allopathic medicine use. Twelve (12) key respondents were subsequently selected, using a non-probability snowball sampling method. They were interviewed in-depth concerning their plant practices and assisted with plant collection. Twenty-four plant (24) species belonging to 15 families were identified for the management of High Blood Pressure and Type 2 Diabetes Mellitus. The most frequently reported families were Asteraceae (20.8%), Lamiaceae (16.67%), Crassulaceae (8.33%) and Aizoaceae (8.33%). The remaining (45.54%) were evenly split over eleven families- Fabaceae, Amaryllidaceae, Anacardiaceae, Capparaceae, Geraniaceae, Apiaceae, Convolvulaceae, Apocynaceae, Rutaceae, Asphodelaceae and Thymelaeaceae. The most commonly used plant species overall was Lessertia frutescens (96.55%). The most frequently used plant parts included leaves (57.63%) roots/bulbs (15.25%) and stems (11.86%), mostly prepared as infusions or decoctions for oral administration. Medicinal plants are widely used by High Blood Pressure and Type 2 Diabetes Mellitus sufferers. They employ diverse plant species to manage both conditions. In addition, some sufferers often use prescribed allopathic medication, as well as medicinal plants, but at different intervals. Despite high usage the plants identified are not currently threatened (Red Data list status: least concern). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Zolnik, Christine P; Makkay, Amanda M; Falco, Richard C; Daniels, Thomas J
2015-09-01
Ticks and whole blood were collected from American black bears (Ursus americanus Pallas) between October 2011 and October 2012 across four counties in northwestern New Jersey, an area where blacklegged ticks (Ixodes scapularis Say) and their associated tick-borne pathogens are prevalent. Adult American dog ticks (Dermacentor variabilis Say) were the most frequently collected tick species in late spring, whereas adult and nymphal blacklegged ticks were found in both the late spring and fall months. Additionally, for blacklegged ticks, we determined the quality of bloodmeals that females acquired from black bears compared with bloodmeals from white-tailed deer (Odocoileus virginianus Zimmerman), the most important host for the adult stage of this tick species. Measures of fecundity after feeding on each host species were not significantly different, suggesting that the bloodmeal a female blacklegged tick acquires from a black bear is of similar quality to that obtained from a white-tailed deer. These results establish the American black bear as both a host and quality bloodmeal source to I. scapularis. Thus, black bears may help support blacklegged tick populations in areas where they are both present. In addition, samples of black bear blood were tested for DNA presence of three tick-borne pathogens. Anaplasma phagocytophilum Foggie and Babesia microti Franca were found in 9.2 and 32.3% of blood samples, respectively. All blood samples were quantitative polymerase chain reaction-negative for Borrelia burgdorferi Johnson, Schmid, Hyde, Steigerwalt, & Brenner. Although circulating pathogens were found in blood, the status of black bears as reservoirs for these pathogens remains unknown. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Saghir, Shakil A; Mendrala, Alan L; Bartels, Michael J; Day, Sue J; Hansen, Steve C; Sushynski, Jacob M; Bus, James S
2006-03-15
Strategies were developed for the estimation of systemically available daily doses of chemicals, diurnal variations in blood levels, and rough elimination rates in subchronic feeding/drinking water studies, utilizing a minimal number of blood samples. Systemic bioavailability of chemicals was determined by calculating area under the plasma concentration curve over 24 h (AUC-24 h) using complete sets of data (> or =5 data points) and also three, two, and one selected time points. The best predictions of AUC-24 h were made when three time points were used, corresponding to Cmax, a mid-morning sample, and C(min). These values were found to be 103 +/- 10% of the original AUC-24 h, with 13 out of 17 values ranging between 96 and 105% of the original. Calculation of AUC-24 h from two samples (Cmax and Cmin) or one mid-morning sample afforded slightly larger variations in the calculated AUC-24 h (69-136% of the actual). Following drinking water exposure, prediction of AUC-24 h using 3 time points (Cmax, mid-morning, and Cmin) was very close to actual values (80-100%) among mice, while values for rats were only 63% of the original due to less frequent drinking behavior of rats during the light cycle. Collection and analysis of 1-3 blood samples per dose may provide insight into dose-proportional or non-dose-proportional differences in systemic bioavailability, pointing towards saturation of absorption or elimination or some other phenomenon warranting further investigation. In addition, collection of the terminal blood samples from rats, which is usually conducted after 18 h of fasting, will be helpful in rough estimation of blood/plasma half-life of the compound. The amount of chemical(s) and/or metabolite(s) in excreta and their possible use as biomarkers in predicting the daily systemic exposure levels are also discussed. Determining these parameters in the early stages of testing will provide critical information to improve the appropriate design of other longer-term toxicity studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saghir, Shakil A.; Mendrala, Alan L.; Bartels, Michael J.
Strategies were developed for the estimation of systemically available daily doses of chemicals, diurnal variations in blood levels, and rough elimination rates in subchronic feeding/drinking water studies, utilizing a minimal number of blood samples. Systemic bioavailability of chemicals was determined by calculating area under the plasma concentration curve over 24 h (AUC-24 h) using complete sets of data ({>=}5 data points) and also three, two, and one selected time points. The best predictions of AUC-24 h were made when three time points were used, corresponding to C {sub max}, a mid-morning sample, and C {sub min}. These values were foundmore » to be 103 {+-} 10% of the original AUC-24 h, with 13 out of 17 values ranging between 96 and 105% of the original. Calculation of AUC-24 h from two samples (C {sub max} and C {sub min}) or one mid-morning sample afforded slightly larger variations in the calculated AUC-24 h (69-136% of the actual). Following drinking water exposure, prediction of AUC-24 h using 3 time points (C {sub max}, mid-morning, and C {sub min}) was very close to actual values (80-100%) among mice, while values for rats were only 63% of the original due to less frequent drinking behavior of rats during the light cycle. Collection and analysis of 1-3 blood samples per dose may provide insight into dose-proportional or non-dose-proportional differences in systemic bioavailability, pointing towards saturation of absorption or elimination or some other phenomenon warranting further investigation. In addition, collection of the terminal blood samples from rats, which is usually conducted after 18 h of fasting, will be helpful in rough estimation of blood/plasma half-life of the compound. The amount of chemical(s) and/or metabolite(s) in excreta and their possible use as biomarkers in predicting the daily systemic exposure levels are also discussed. Determining these parameters in the early stages of testing will provide critical information to improve the appropriate design of other longer-term toxicity studies.« less
Platelet factor 4/heparin antibodies in blood bank donors.
Hursting, Marcie J; Pai, Poulomi J; McCracken, Julianna E; Hwang, Fred; Suvarna, Shayela; Lokhnygina, Yuliya; Bandarenko, Nicholas; Arepally, Gowthami M
2010-11-01
Platelet factor 4 (PF4)/heparin antibody, typically associated with heparin therapy, is reported in some heparin-naive people. Seroprevalence in the general population, however, remains unclear. We prospectively evaluated PF4/heparin antibody in approximately 4,000 blood bank donors using a commercial enzyme-linked immunosorbent assay for initial and then repeated (confirmatory) testing. Antibody was detected initially in 249 (6.6%; 95% confidence interval [CI], 5.8%-7.4%) of 3,795 donors and repeatedly in 163 (4.3%; 95% CI, 3.7%-5.0%) of 3,789 evaluable donors. "Unconfirmed" positives were mostly (93%) low positives (optical density [OD] = 0.40-0.59). Of 163 repeatedly positive samples, 116 (71.2%) were low positives, and 124 (76.1%) exhibited heparin-dependent binding. Predominant isotypes of intermediate to high seropositive samples (OD >0.6) were IgG (20/39 [51%]), IgM (9/39 [23%]), and indeterminate (10/39 [26%]). The marked background seroprevalence of PF4/heparin antibody (4.3%-6.6%) with the preponderance of low (and frequently nonreproducible) positives in blood donors suggests the need for further assay calibration, categorization of antibody level, and studies evaluating clinical relevance of "naturally occurring" PF4/heparin antibodies.
Frequency and causes of infectious abortion in a dairy herd in Queretaro, Mexico.
Escamilla, H Patricia; Martínez, M José Juan; Medina, C Mario; Morales, S Elizabeth
2007-10-01
The objective of this study was to determine the frequency of infectious bovine abortion and to identify some of its causes, specifically brucellosis, leptospirosis, bovine viral diarrhea, infectious bovine rhinotracheitis, and neosporosis. The study was carried out in a dairy herd in the state of Queretaro, Mexico, between September 2002 and March 2003. At the beginning of the study, blood samples were taken from a random 33% of the 300 lactating or pregnant cows; antibodies against Leptospira interrogans were the most commonly identified, in 91% of the 99 samples. Blood samples were also taken 14 to 28 d after the 26 subsequent abortions in the herd in the 6-mo study period, as well as from 22 cows that had not aborted within 5 d after the abortions in the other group. Seroconversion was most frequent for L. hardjo, occurring in 8 (67%) of the 12 dams that aborted after the initial serologic sampling and for which paired serum samples were therefore available. Of the 16 collected fetuses, 10 had histologic lesions suggesting infection in various organs, the features correlating with the serologic results for the dams in 7 cases. Thus, the abortions may have been caused by more than 1 infectious agent.
Frequency and causes of infectious abortion in a dairy herd in Queretaro, Mexico
Escamilla, H. Patricia; Martínez, M. José Juan; Medina, C. Mario; Morales, S. Elizabeth
2007-01-01
The objective of this study was to determine the frequency of infectious bovine abortion and to identify some of its causes, specifically brucellosis, leptospirosis, bovine viral diarrhea, infectious bovine rhinotracheitis, and neosporosis. The study was carried out in a dairy herd in the state of Queretaro, Mexico, between September 2002 and March 2003. At the beginning of the study, blood samples were taken from a random 33% of the 300 lactating or pregnant cows; antibodies against Leptospira interrogans were the most commonly identified, in 91% of the 99 samples. Blood samples were also taken 14 to 28 d after the 26 subsequent abortions in the herd in the 6-mo study period, as well as from 22 cows that had not aborted within 5 d after the abortions in the other group. Seroconversion was most frequent for L. hardjo, occurring in 8 (67%) of the 12 dams that aborted after the initial serologic sampling and for which paired serum samples were therefore available. Of the 16 collected fetuses, 10 had histologic lesions suggesting infection in various organs, the features correlating with the serologic results for the dams in 7 cases. Thus, the abortions may have been caused by more than 1 infectious agent. PMID:17955907
Guven, Esin; Avcioglu, Hamza; Deniz, Ahmet; Balkaya, İbrahim; Abay, Ugur; Yavuz, Şevki; Akyüz, Muzaffer
2017-03-01
Equine piroplasmosis (EP) is a hemoprotozoan tick-borne disease with worldwide distribution that is caused by Theileria equi and Babesia caballi. There are studies reporting the presence of equine piroplasmosis in Turkey but the situation in Erzurum is unknown. The aim of the current study was to determine the situation of equine piroplasmosis in jeered horses in Erzurum. Between April and August 2015, a total of 125 Arabian horse were examined and blood samples were collected. At the time of sampling, animals were also examined for tick infestations and clinical signs. Besides microscopic examination of Giemsastained blood smears, multiplex PCR performed with species specific primers partially amplifying the 18S rRNA gene of B. caballi and T. equi. During the microscopic examination of blood smears, T. equi piroplasms were found in 6 (4.8%) samples. In total, 11 (8.8%) T. equi DNA were detected with multiplex PCR. B. caballi piroplasms or DNA were not obtained. BLAST analysis of the sequenced T. equi samples (GenBank: KU921661-KU921667) indicated 98.8-100% identity to each other, and 100% similarity to T. equi isolates in South Africa, Iran, China, Sudan, India, Mongolia, Trinidad, Kenya, Spain, Serbia, Bosnia and Herzegovina and Turkey (Bursa). The results of our study indicate that T. equi occurs more frequently than B. caballi in the study area. To the authors' knowledge, this is the first report of the molecular detection of equine piroplasmosis in jeered horses in Erzurum, Turkey.
Vivanti, Alexandre; Soheili, Tayebeh S.; Cuccuini, Wendy; Luce, Sonia; Mandelbrot, Laurent; Lechenadec, Jerome; Cordier, Anne-Gael; Azria, Elie; Soulier, Jean; Cavazzana, Marina; Blanche, Stéphane; André-Schmutz, Isabelle
2015-01-01
Objectives: Zidovudine and tenofovir are the two main nucleos(t)ide analogs used to prevent mother-to-child transmission of HIV. In vitro, both drugs bind to and integrate into human DNA and inhibit telomerase. The objective of the present study was to assess the genotoxic effects of either zidovudine or tenofovir-based combination therapies on cord blood cells in newborns exposed in utero. Design: We compared the aneuploid rate and the gene expression profiles in cord blood samples from newborns exposed either to zidovudine or tenofovir-based combination therapies during pregnancy and from unexposed controls (n = 8, 9, and 8, respectively). Methods: The aneuploidy rate was measured on the cord blood T-cell karyotype. Gene expression profiles of cord blood T cells and hematopoietic stem and progenitor cells were determined with microarrays, analyzed in a gene set enrichment analysis and confirmed by real-time quantitative PCRs. Results: Aneuploidy was more frequent in the zidovudine-exposed group (26.3%) than in the tenofovir-exposed group (14.2%) or in controls (13.3%; P < 0.05 for both). The transcription of genes involved in DNA repair, telomere maintenance, nucleotide metabolism, DNA/RNA synthesis, and the cell cycle was deregulated in samples from both the zidovudine and the tenofovir-exposed groups. Conclusion: Although tenofovir has a lower clastogenic impact than zidovudine, gene expression profiling showed that both drugs alter the transcription of DNA repair and telomere maintenance genes. PMID:25513819
Vivanti, Alexandre; Soheili, Tayebeh S; Cuccuini, Wendy; Luce, Sonia; Mandelbrot, Laurent; Lechenadec, Jerome; Cordier, Anne-Gael; Azria, Elie; Soulier, Jean; Cavazzana, Marina; Blanche, Stéphane; André-Schmutz, Isabelle
2015-07-17
Zidovudine and tenofovir are the two main nucleos(t)ide analogs used to prevent mother-to-child transmission of HIV. In vitro, both drugs bind to and integrate into human DNA and inhibit telomerase. The objective of the present study was to assess the genotoxic effects of either zidovudine or tenofovir-based combination therapies on cord blood cells in newborns exposed in utero. We compared the aneuploid rate and the gene expression profiles in cord blood samples from newborns exposed either to zidovudine or tenofovir-based combination therapies during pregnancy and from unexposed controls (n = 8, 9, and 8, respectively). The aneuploidy rate was measured on the cord blood T-cell karyotype. Gene expression profiles of cord blood T cells and hematopoietic stem and progenitor cells were determined with microarrays, analyzed in a gene set enrichment analysis and confirmed by real-time quantitative PCRs. Aneuploidy was more frequent in the zidovudine-exposed group (26.3%) than in the tenofovir-exposed group (14.2%) or in controls (13.3%; P < 0.05 for both). The transcription of genes involved in DNA repair, telomere maintenance, nucleotide metabolism, DNA/RNA synthesis, and the cell cycle was deregulated in samples from both the zidovudine and the tenofovir-exposed groups. Although tenofovir has a lower clastogenic impact than zidovudine, gene expression profiling showed that both drugs alter the transcription of DNA repair and telomere maintenance genes.
Kemp, Matthew W; Ahmed, Shatha; Beeton, Michael L; Payne, Matthew S; Saito, Masatoshi; Miura, Yuichiro; Usuda, Haruo; Kallapur, Suhas G; Kramer, Boris W; Stock, Sarah J; Jobe, Alan H; Newnham, John P; Spiller, Owen B
2017-01-01
Complement is a central defence against sepsis, and increasing complement insufficiency in neonates of greater prematurity may predispose to increased sepsis. Ureaplasma spp. are the most frequently cultured bacteria from preterm blood samples. A sheep model of intrauterine Ureaplasma parvum infection was used to examine in vivo Ureaplasma bacteraemia at early and late gestational ages. Complement function and Ureaplasma killing assays were used to determine the correlation between complement potency and bactericidal activity of sera ex vivo. Ureaplasma was cultured from 50% of 95-day gestation lamb cord blood samples compared to 10% of 125-day gestation lambs. Bactericidal activity increased with increased gestational age, and a direct correlation between functional complement activity and bactericidal activity (R 2 =.86; P<.001) was found for 95-day gestational lambs. Ureaplasma bacteraemia in vivo was confined to early preterm lambs with low complement function, but Ureaplasma infection itself did not diminish complement levels. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
White, Brandi M; Bonilha, Heather Shaw; Ellis, Charles
2016-03-01
Childhood lead poisoning is a serious public health problem with long-term adverse effects. Healthy People 2020's environmental health objective aims to reduce childhood blood lead levels; however, efforts may be hindered by potential racial/ethnic differences. Recent recommendations have lowered the blood lead reference level. This review examined racial/ethnic differences in blood lead levels among children under 6 years of age. We completed a search of PubMed, CINAHL, and PsycINFO databases for published works from 2002 to 2012. We identified studies that reported blood lead levels and the race/ethnicity of at least two groups. Ten studies met inclusion criteria for the review. Blood lead levels were most frequently reported for black, white, and Hispanic children. Six studies examined levels between blacks, whites, and Hispanics and two between blacks and whites. Studies reporting mean lead levels among black, whites, and Hispanics found that blacks had the highest mean blood lead level. Additionally, studies reporting blood lead ranges found that black children were more likely to have elevated levels. Studies suggest that black children have higher blood lead levels compared to other racial/ethnic groups. Future studies are warranted to obtain ample sample sizes for several racial/ethnic groups to further examine differences in lead levels.
... If you have diabetes, prednisolone may increase your blood sugar level. If you monitor your blood sugar (glucose) at home, test your blood or urine ... frequently than usual. Call your doctor if your blood sugar is high.Do not let anyone else take ...
Loss of chromosome Y in blood, but not in brain, of suicide completers.
Kimura, Atsushi; Hishimoto, Akitoyo; Otsuka, Ikuo; Okazaki, Satoshi; Boku, Shuken; Horai, Tadasu; Izumi, Takeshi; Takahashi, Motonori; Ueno, Yasuhiro; Shirakawa, Osamu; Sora, Ichiro
2018-01-01
Men have a higher rate of completed suicide than women, which suggests that sex chromosome abnormalities may be related to the pathophysiology of suicide. Recent studies have found an aberrant loss of chromosome Y (LOY) in various diseases; however, no study has investigated whether there is an association between LOY and suicide. The purpose of this study was to determine whether LOY occurs in men who completed suicide. Our study consisted of 286 male Japanese subjects comprised of 140 suicide completers without severe physical illness (130 post-mortem samples of peripheral blood and 10 brains) and 146 age-matched control subjects (130 peripheral blood samples from healthy individuals and 16 post-mortem brains). LOY was measured as the chromosome Y/chromosome X ratio of the fluorescent signal of co-amplified short sequences from the Y-X homologous amelogenin genes (AMELY and AMELX). Regression analyses showed that LOY in the blood of suicide completers was significantly more frequent than that found in controls (odds ratio = 3.50, 95% confidence interval = 1.21-10.10), but not in the dorsolateral prefrontal cortex (DLPFC) region of brain. Normal age-dependent LOY in blood was found in healthy controls (r = -0.353, p < 0.001), which was not seen in suicide completers (r = -0.119, p = 0.177). DLPFC tissue had age-dependent LOY (B = -0.002, p = 0.015), which was independent of phenotype. To our knowledge, this is the first study demonstrating that LOY in blood is associated with suicide completion. In addition, our findings are the first to also indicate that age-dependent LOY may occur not only in blood, but also in specific brain regions.
... following: Glucose intolerance (body has problem breaking down sugars) High blood sugar (hyperglycemia) Diarrhea Excessive thirst (due to high blood sugar) Frequent urination (due to high blood sugar) Increased appetite Inflamed mouth and tongue ...
Hospital-acquired Anemia in Critically Ill Dogs and Cats: A Multi-Institutional Study.
Lynch, A M; Respess, M; Boll, A E; Bozych, M; McMichael, M; Fletcher, D J; De Laforcade, A M; Rozanski, E A
2016-01-01
Hospital-acquired anemia is commonly described in people but limited information currently is available regarding its prevalence in animals. Assess the prevalence of hospital-acquired anemia in hospitalized critically ill dogs and cats, and examine its relationship with phlebotomy practices, transfusion administration, and survival to discharge. Eight hundred and fifty-one client-owned animals (688 dogs and 163 cats). A multicenter, observational study was conducted in which packed cell volume (PCV) was recorded at the time of admission and on subsequent hospitalization days. Signalment, number of blood samples obtained, underlying disease, whether or not blood products were administered, duration of hospitalization, and survival to discharge were recorded. Admission anemia prevalence was 32%, with overall prevalence during the hospitalization period of 56%. The last recorded PCV was significantly lower than the admission PCV for both dogs (admission PCV, 42% [range, 6-67%]; last recorded PCV, 34% [range, 4-64%], P < .0001) and cats (admission PCV, 31% [range, 6-55%]; last recorded PCV, 26% [range, 10-46%], P < .0001). Patients that developed anemia had significantly more blood samples obtained (nonanemic, 5 blood samples [range, 2-54]; anemic, 7 blood samples [range, 2-49], P < .0001). Hospitalized cats were significantly more likely to develop anemia compared to dogs (P < .0001), but anemic dogs were significantly less likely to survive to discharge (P = .0001). Surgical patients were at higher risk of developing hospital-acquired anemia compared to medical patients (OR, 0.63; 95% CI, 0.4-0.9; P = .01). Hospital-acquired anemia occurred frequently, especially in surgical patients. Additional studies focused on the direct effect of phlebotomy practices on the likelihood of anemia development in hospitalized animals are warranted. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris
2017-10-24
Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.
[Confrontation of knowledge on alcohol concentration in blood and in exhaled air].
Bauer, Miroslav; Bauerová, Jiřina; Šikuta, Ján; Šidlo, Jozef
2015-01-01
The authors of the paper give a brief historical overview of the development of experimental alcohology in the former Czechoslovakia. Enhanced attention is paid to tests of work quality control of toxicological laboratories. Information on results of control tests of blood samples using the method of gas chromatography in Slovakia and within a world-wide study "Eurotox 1990" is presented. There are pointed out the pitfalls related to objective evaluation of the analysis results interpreting alcohol concentration in biological materials and the associated need to eliminate a negative influence of the human factor. The authors recommend performing analyses of alcohol in biological materials only at accredited workplaces and in the case of samples storage to secure a mandatory inhibition of phosphorylation process. There are analysed the reasons of numerical differences of analyses while taking evidence of alcohol in blood and in exhaled air. The authors confirm analysis accuracy using the method of gas chromatography along with breath analysers of exhaled air. They highlight the need for making the analysis results more objective also through confrontation with the results of clinical examination and with examined circumstances. The authors suggest a method of elimination of the human factor, the most frequently responsible for inaccuracy, to a tolerable level (safety factor) and the need of sample analysis by two methods independent of each other or the need of analysis of two biological materials.
The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation
Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi
2016-01-01
The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid. PMID:27513941
Oriol, Isabel; Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi
2016-01-01
The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid.
A rate-based transcutaneous CO2 sensor for noninvasive respiration monitoring.
Chatterjee, M; Ge, X; Kostov, Y; Luu, P; Tolosa, L; Woo, H; Viscardi, R; Falk, S; Potts, R; Rao, G
2015-05-01
The pain and risk of infection associated with invasive blood sampling for blood gas measurements necessitate the search for reliable noninvasive techniques. In this work we developed a novel rate-based noninvasive method for a safe and fast assessment of respiratory status. A small sampler was built to collect the gases diffusing out of the skin. It was connected to a CO2 sensor through gas-impermeable tubing. During a measurement, the CO2 initially present in the sampler was first removed by purging it with nitrogen. The gases in the system were then recirculated between the sampler and the CO2 sensor, and the CO2 diffusion rate into the sampler was measured. Because the measurement is based on the initial transcutaneous diffusion rate, reaching mass transfer equilibrium and heating the skin is no longer required, thus, making it much faster and safer than traditional method. A series of designed experiments were performed to analyze the effect of the measurement parameters such as sampler size, measurement location, subject positions, and movement. After the factor analysis tests, the prototype was sent to a level IV NICU for clinical trial. The results show that the measured initial rate of increase in CO2 partial pressure is linearly correlated with the corresponding arterial blood gas measurements. The new approach can be used as a trending tool, making frequent blood sampling unnecessary for respiratory status monitoring.
Blood Frequently Asked Questions
... women who have ever engaged in sex for money or drugs Anyone who has had hepatitis since ... places where blood donations can be made. Bloodmobiles (mobile blood drives on specially constructed buses) travel to ...
Preeclampsia and High Blood Pressure During Pregnancy
... AQ FREQUENTLY ASKED QUESTIONS FAQ034 PREGNANCY Preeclampsia and High Blood Pressure During Pregnancy • What is high blood pressure? • What is chronic hypertension? • What is gestational hypertension? • ...
Blood specimen labelling errors: Implications for nephrology nursing practice.
Duteau, Jennifer
2014-01-01
Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.
Plasmodium ovale in Indonesia.
Baird, J K; Purnomo; Masbar, S
1990-12-01
We report 34 infections by Plasmodium ovale found among 15,806 blood film examinations taken between 1973 and 1989 from several sites in Indonesia. Twenty five of the P. ovale infections occurred in a single sample of 514 people living in Owi, Irian Jaya. We detected five additional infections at 3 other sites in Irian Jaya. Other infections by P. ovale occurred at two sites in West Flores. Another infection has already been reported from East Timor. Despite relatively frequent sampling of populations on Sumatra, Kalimantan, Java and Sulawesi, P. ovale has not been found on those islands. It appears that this parasite occurs only on the easternmost islands of the Indonesian archipelago where it is nonetheless a rare finding.
NASA Technical Reports Server (NTRS)
Alfrey, Clarence P.
1995-01-01
The purpose of this contract was to design and conduct experiments that would increase our understanding of the influence of space flight on erythrokinetics and the rapid change that occurs in the red blood cell mass during spaceflight. The experiment designated E261, was flown on Space Life Science missions SLS-1 and SLS-2 (STS 40 and STS 58). Unique features of this experiment included radionuclide tracer studies during flight and frequent in-flight blood samples specifically for the first three or four days of the mission. Plasma volume measurements were made early and late in the missions. Radioactive iron kinetics studies were initiated after one or three days in microgravity since the magnitude of the red blood cell mass decrease dictated that bone marrow production must be decreased very early in the flight. The schedule was designed to study the time course of the changes that occur during spaceflight and to possibly define a mechanism for the rapid reduction in red blood cell mass.
Rjeibi, M R; Darghouth, M A; Rekik, M; Amor, B; Sassi, L; Gharbi, M
2016-06-01
Theileria lestoquardi is the most prominent Theileria species in small ruminants that causes malignant theileriosis of sheep in Africa and Asia. In the present survey, blood samples and ticks were collected in Kebili (southern Tunisia) from 166 Queue Fine de l'Ouest sheep. Giemsa-stained blood smears, immunofluorescent antibody test (IFAT) and PCR were performed. The DNA was extracted from blood and analysed by PCR targeting 18S rRNA gene of Theileria spp. and then sequenced. A total number of 140 ticks were collected from a total number of 166 sheep during the four seasons. The ticks belonged to two genera and 4 species; the most frequent tick was Hyalomma excavatum 84.3% (118/140) and then Rhipicephalus spp. 15.7% (22/140). Only two animals had positive Giemsa-stained blood smears, and they were also positive by IFAT. The amplicons had 99.3 and 99.6% homology with the BLAST published T. lestoquardi amplicons. To our knowledge, this is the first report of T. lestoquardi in small ruminants within the Maghreb region. © 2014 Blackwell Verlag GmbH.
Robson, J.; Ashkar, T. S.
1972-01-01
A preliminary survey of 2 073 domestic animals in the Lambwe Valley, Kenya, showed a 7.4% rate of infection with Trypanosoma congolense and T. vivax. In comprehensive surveys covering 6 384 domestic stock, pathogenic trypanosomes were found in 17.0% of cattle, 5.0% of sheep, and 2.1% of goats. Adults were more often infected than young animals, and males more often than females. T. congolense was the trypanosome most frequently diagnosed, followed by T. vivax and the T. brucei subgroup. T. theileri was also found. The examination of wet blood films in the field as a means of diagnosing trypanosome infections was shown to be valueless. More infections were detected in peripheral blood films than in systemic blood films, but both should be examined. An examination of smears of glandular fluid is essential for the diagnosis of T. vivax in cattle, while mouse-inoculation tests are necessary for the diagnosis of the T. brucei subgroup. The detection of T. vivax was improved by the high-speed centrifugation of blood samples in capillary tubes. PMID:4544823
Miller, Michael A; Rosin, Alex; Levsky, Marc E; Patel, Manish M; Gregory, Timothy J D; Crystal, Chad S
2006-11-01
Ethanol-based hand sanitizers (EBHSs) are used in most health care facilities in the United States. Infection control personnel advocate the use of generous quantities of EBHS before and after contact with patients. Although it is assumed that little systemic absorption of ethanol occurs during EBHS use, many alcohols are absorbed to varying degrees via the transdermal route. Ethanol intoxication by employees in the medical workplace is a potentially serious finding, and it is of forensic and medical-legal importance to elucidate the effects of frequent use of EBHS upon serum blood ethanol levels (BELs). To investigate the effect of frequent use of EBHS upon serum blood ethanol concentrations, we prospectively studied 5 volunteers undergoing frequent application of EBHS. Enrolled subjects applied 5 mL of the product (62% denatured ethyl alcohol manufactured by Kimberley-Clark, Roswell, GA) to both hands and rubbed until dry. This activity was repeated 50 times over 4 hours. Participants had their blood drawn before as well as after completing the study. Each participant was without alcohol exposure during the 12 hours preceding the study. Five volunteers were enrolled. All had an initial blood ethanol level of less than 5 mg/dL. All 5 participants completed the 4-hour study. There were no noted adverse reactions during the study. Blood ethanol level upon completion of the 50 applications of EBHS was less than 5 mg/dL in all 5 study participants. The results of this study demonstrate that use of ethanol-based hand sanitizers, when frequently used in accordance with labeling, do not raise serum blood ethanol levels.
Aggarwal, Brooke; Makarem, Nour; Shah, Riddhi; Emin, Memet; Wei, Ying; St-Onge, Marie-Pierre; Jelic, Sanja
2018-06-09
Insufficient sleep increases blood pressure. However, the effects of milder, highly prevalent but frequently neglected sleep disturbances, including poor sleep quality and insomnia, on vascular health in women are unclear. We investigated whether poor sleep patterns are associated with blood pressure and endothelial inflammation in a diverse sample of women. Women who participated in the ongoing American Heart Association Go Red for Women Strategically Focused Research Network were studied (n=323, 57% minority, mean age=39±17 years, range=20-79 years). Sleep duration, sleep quality, and time to sleep onset were assessed using the Pittsburgh Sleep Quality Index (score ≥5=poor sleep quality). Risk for obstructive sleep apnea was evaluated using the Berlin questionnaire, and insomnia was assessed using the Insomnia Severity Index. In a subset of women who participated in the basic study (n=26), sleep duration was assessed objectively using actigraphy, and endothelial inflammation was assessed directly in harvested endothelial cells by measuring nuclear translocation of nuclear factor kappa B. Vascular reactivity was measured by brachial artery flow-mediated dilation (n=26). Systolic and diastolic blood pressure were measured by trained personnel (n=323). Multivariable linear regressions were used to evaluate associations between sleep patterns and blood pressure, nuclear factor kappa B, and flow-mediated dilation. Mean sleep duration was 6.8±1.3 hours/night in the population study and 7.5±1.1 hour/night in the basic study. In the population study sample, 50% had poor sleep quality versus 23% in the basic study, and 37% had some level of insomnia versus 15% in the basic study. Systolic blood pressure was associated directly with poor sleep quality, and diastolic blood pressure was of borderline significance with obstructive sleep apnea risk after adjusting for confounders ( P =0.04 and P =0.08, respectively). Poor sleep quality was associated with endothelial nuclear factor kappa B activation (β=30.6; P =0.03). Insomnia and longer sleep onset latency were also associated with endothelial nuclear factor kappa B activation (β=27.6; P =0.002 and β=8.26; P =0.02, respectively). No evidence was found for an association between sleep and flow-mediated dilation. These findings provide direct evidence that common but frequently neglected sleep disturbances such as poor sleep quality and insomnia are associated with increased blood pressure and vascular inflammation even in the absence of inadequate sleep duration in women. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02835261. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Mastrokolias, Anastasios; Pool, Rene; Mina, Eleni; Hettne, Kristina M; van Duijn, Erik; van der Mast, Roos C; van Ommen, GertJan; 't Hoen, Peter A C; Prehn, Cornelia; Adamski, Jerzy; van Roon-Mom, Willeke
Metabolic changes have been frequently associated with Huntington's disease (HD). At the same time peripheral blood represents a minimally invasive sampling avenue with little distress to Huntington's disease patients especially when brain or other tissue samples are difficult to collect. We investigated the levels of 163 metabolites in HD patient and control serum samples in order to identify disease related changes. Additionally, we integrated the metabolomics data with our previously published next generation sequencing-based gene expression data from the same patients in order to interconnect the metabolomics changes with transcriptional alterations. This analysis was performed using targeted metabolomics and flow injection electrospray ionization tandem mass spectrometry in 133 serum samples from 97 Huntington's disease patients (29 pre-symptomatic and 68 symptomatic) and 36 controls. By comparing HD mutation carriers with controls we identified 3 metabolites significantly changed in HD (serine and threonine and one phosphatidylcholine-PC ae C36:0) and an additional 8 phosphatidylcholines (PC aa C38:6, PC aa C36:0, PC ae C38:0, PC aa C38:0, PC ae C38:6, PC ae C42:0, PC aa C36:5 and PC ae C36:0) that exhibited a significant association with disease severity. Using workflow based exploitation of pathway databases and by integrating our metabolomics data with our gene expression data from the same patients we identified 4 deregulated phosphatidylcholine metabolism related genes ( ALDH1B1 , MBOAT1 , MTRR and PLB1 ) that showed significant association with the changes in metabolite concentrations. Our results support the notion that phosphatidylcholine metabolism is deregulated in HD blood and that these metabolite alterations are associated with specific gene expression changes.
Mura, P; Chatelain, C; Dumestre, V; Gaulier, J M; Ghysel, M H; Lacroix, C; Kergueris, M F; Lhermitte, M; Moulsma, M; Pépin, G; Vincent, F; Kintz, P
2006-07-13
A collaborative study was conducted in France in order to determine the prevalence of cannabinoids, opiates, cocaine metabolites and amphetamines in blood samples from drivers killed in road accidents in 2003 and 2004 and to compare these values with those of a previous study performed during the period 2000-2001 involving 900 drivers. Blood samples were provided from 2003 under 30-year-old drivers, killed in a traffic accident. Drugs of abuse were determined by gas chromatography-mass spectrometry using the same analytical procedures in all the 12 laboratories. The most frequently observed compounds were by far cannabinoids, that tested positive in 39.6% of the total number of samples. Delta9 tetrahydrocannabinol (THC), the most active of the principle constituents in marijuana (cannabis sativa), was detected in the blood of 28.9% drivers and was the single drug of abuse in 80.2% of the positive cases. It was associated with amphetamines in 7.4% and with opiates and cocaine in 1.9 and 4.8%, respectively. Amphetamines were present in 3.1% of the total number of samples, cocaine metabolites in 3.0% and opiates in 3.5%. When comparing these results with those of a previous study performed 3 years before, a significant increase is observed for THC (28.9% versus 16.9%), cocaine metabolites (3.0% versus 0.2%) and amphetamines (3.1% versus 1.4%). This study demonstrates the critical necessity of implementing in France as soon as possible systematical roadside testing for drugs of abuse.
Serieys, Laurel E.K.; Armenta, Tiffany C.; Moriarty, Joanne G.; Boydston, Erin E.; Lyren, Lisa M.; Poppenga, Robert H.; Crooks, Kevin R.; Wayne, Robert K.; Riley, Seth P. D.
2015-01-01
Anticoagulant rodenticides (ARs) are increasingly recognized as a threat to nontarget wildlife. High exposure to ARs has been documented globally in nontarget predatory species and linked to the high prevalence of an ectoparasitic disease, notoedric mange. In southern California, mange associated with AR exposure has been the proximate cause of a bobcat (Lynx rufus) population decline. We measured AR exposure in bobcats from two areas in southern California, examining seasonal, demographic and spatial risk factors across landscapes including natural and urbanized areas. The long-term study included bobcats sampled over a 16-year period (1997–2012) and a wide geographic area. We sampled blood (N = 206) and liver (N = 172) to examine exposure ante- and post-mortem. We detected high exposure prevalence (89 %, liver; 39 %, blood) and for individuals with paired liver and blood data (N = 64), 92 % were exposed. Moreover, the animals with the most complete sampling were exposed most frequently to three or more compounds. Toxicant exposure was associated with commercial, residential, and agricultural development. Bobcats of both sexes and age classes were found to be at high risk of exposure, and we documented fetal transfer of multiple ARs. We found a strong association between certain levels of exposure (ppm), and between multiple AR exposure events, and notoedric mange. AR exposure was prevalent throughout both regions sampled and throughout the 16-year time period in the long-term study. ARs pose a substantial threat to bobcats, and likely other mammalian and avian predators, living at the urban-wildland interface.
High blood pressure and insulin resistance: influence of ethnic background.
Ferrannini, E; Haffner, S M; Stern, M P; Mitchell, B D; Natali, A; Hazuda, H P; Patterson, J K
1991-06-01
Hyperinsulinaemia links non-insulin dependent diabetes (NIDDM), obesity, and hypertension, each an insulin-resistant state in its own right. Insulin resistance predicts the occurrence of NIDDM, and plays a major role in its pathogenesis. We tested the hypothesis that hyperinsulinaemia may also predict hypertension in a sample (n = 2905) of the mixed population of San Antonio, in which hyperinsulinaemia and NIDDM are more prevalent among Mexican-Americans than non-Hispanic whites. Whilst in the whole sample the hypertensives had significantly (P less than 0.001) higher plasma insulin concentrations than the normotensives, high blood pressure was significantly (P less than 0.01) more frequent among non-Hispanic whites than Mexican-Americans regardless of diabetes status. After adjusting for factors (age, sex, body mass, and body fat distribution) known to affect insulin levels, a direct relationship between post-glucose plasma insulin concentrations and prevalence of hypertension was still present in both ethnic groups. In Mexican-Americans, however, the standardized prevalence of hypertension was significantly (P less than 0.001) lower at any given insulin concentration. Post-glucose plasma glucose levels also were directly related to hypertension prevalence in both groups; again, the regression line was shifted downward and, furthermore, less steep (P less than 0.02) in Mexican-Americans, suggesting relative protection against the negative effect of hyperglycaemia on blood pressure. Dyslipidaemia (higher total cholesterol and triglyceride, and lower HDL-cholesterol concentrations) was strongly associated with hyperinsulinaemia and blood pressure in both ethnic groups. After adjusting for plasma insulin, only hypertriglyceridaemia was associated with high blood pressure, with no inter-ethnic difference.(ABSTRACT TRUNCATED AT 250 WORDS)
Probstfield, Jeffery; Hire, Donald; Redmon, J. Bruce; Evans, Gregory W.; Coday, Mace; Lewis, Cora E.; Johnson, Karen C.; Wilmoth, Sharon; Bahnson, Judy; Dulin, Michael F.; Green, Jennifer B.; Knowler, William C.; Kitabchi, Abbas; Murillo, Anne L.; Osei, Kwame; Rehman, Shakaib U.; Cushman, William C.
2015-01-01
BACKGROUND The relative effectiveness of 3 approaches to blood pressure control—(i) an intensive lifestyle intervention (ILI) focused on weight loss, (ii) frequent goal-based monitoring of blood pressure with pharmacological management, and (iii) education and support—has not been established among overweight and obese adults with type 2 diabetes who are appropriate for each intervention. METHODS Participants from the Action for Health in Diabetes (Look AHEAD) and the Action to Control Cardiovascular Risk in Diabetes (ACCORD) cohorts who met criteria for both clinical trials were identified. The proportions of these individuals with systolic blood pressure (SBP) <140mm Hg from annual standardized assessments over time were compared with generalized estimating equations. RESULTS Across 4 years among 480 Look AHEAD and 1,129 ACCORD participants with baseline SBPs between 130 and 159mm Hg, ILI (OR = 1.46; 95% CI = [1.18–1.81]) and frequent goal-based monitoring with pharmacotherapy (OR = 1.51; 95% CI = [1.16–1.97]) yielded higher rates of blood pressure control compared to education and support. The intensive behavioral-based intervention may have been more effective among individuals with body mass index >30kg/m2, while frequent goal-based monitoring with medication management may be more effective among individuals with lower body mass index (interaction P = 0.047). CONCLUSIONS Among overweight and obese adults with type 2 diabetes, both ILI and frequent goal-based monitoring with pharmacological management can be successful strategies for blood pressure control. CLINICAL TRIALS REGISTRY clinicaltrials.gov identifiers NCT00017953 (Look AHEAD) and NCT00000620 (ACCORD). PMID:25666468
Wireless connection of continuous glucose monitoring system to the electronic patient record
NASA Astrophysics Data System (ADS)
Murakami, Alexandre; Gutierrez, Marco A.; Lage, Silvia G.; Rebelo, Marina S.; Granja, Luiz A. R.; Ramires, Jose A. F.
2005-04-01
The control of blood sugar level (BSL) at near-normal levels has been documented to reduce both acute and chronic complications of diabetes mellitus. Recent studies suggested, the reduction of mortality in a surgical intensive care unit (ICU), when the BSL are maintained at normal levels. Despite of the benefits appointed by these and others clinical studies, the strict BSL control in critically ill patients suffers from some difficulties: a) medical staff need to measure and control the patient"s BSL using blood sample at least every hour. This is a complex and time consuming task; b) the inaccuracy of standard capillary glucose monitoring (fingerstick) in hypotensive patients and, if frequently used to sample arterial or venous blood, may lead to excess phlebotomy; c) there is no validated procedure for continuously monitoring of BSL levels. This study used the MiniMed CGMS in ill patients at ICU to send, in real-time, BSL values to a Web-Based Electronic Patient Record. The BSL values are parsed and delivered through a wireless network as an HL7 message. The HL7 messages with BSL values are collected, stored into the Electronic Patient Record and presented into a bed-side monitor at the ICU together with other relevant patient information.
Moats, W A
1985-01-01
Tylosin, an antibiotic developed specifically for agricultural use, and erythromycin are the main macrolide antibiotics used in animal production. Two-dimensional thin layer chromatography has been used for detection of tylosin in poultry meat, eggs, and milk and for erythromycin in poultry meat. Detection limits reported are, for tylosin, 0.1 ppm in poultry meat, 0.05 ppm in egg, and 0.01 ppm in milk, and for erythromycin, 0.25 ppm in poultry meat. Liquid chromatography (LC) has also been used for determination of tylosin in milk, blood, and tissues of animals. Samples (milk, blood serum, or tissue homogenates in water or pH 2.2 buffer) were deproteinized with acetonitrile, tylosin was partitioned into methylene chloride, and the extracts were concentrated and dissolved in acetonitrile. Chromatography was done on a reverse phase end-capped C18 column using 0.002-0.005 M ammonium dihydrogen phosphate-acetonitrile-methanol (10 + 60 + 30-5 + 80 + 15). Solvent composition was varied with the type of sample analyzed. The method will detect 0.1 ppm tylosin in tissues and less in milk and blood serum. The LC method was more sensitive than microbiological assays for detection of tylosin in tissues of treated swine; recoveries of tylosin by the LC method were frequently several-fold higher.
Petti, Stefano; Moroni, Catia; Messano, Giuseppe Alessio; Polimeni, Antonella
2013-03-01
Oral streptococci detected in water from dental unit water lines (DUWLs) are a surrogate marker of patients' biological fluid retraction during therapy. We investigated oral streptococci detection rate in DUWLs in a representative sample of private offices in real-life conditions. Samples of nondisinfected water (100 ml) were collected from the DUWL designated for the air turbine handpiece in 81 dental units, immediately after dental treatment of patients with extensive air turbine handpiece use. Water was filtered and plated on a selective medium for oral streptococci and, morphologically, typical colonies of oral streptococci were counted. The lowest detection limit was 0.01 CFU/ml. The oral streptococci detection rate was 72% (95% CI: 62-81%), with a mean level of 0.7 CFU/ml. Oral streptococci detection was not affected by handpiece age or dental treatment type, but was associated with dental unit age. Biological fluid retraction into DUWLs during patient treatment and, possibly, the risk for patient-to-patient blood- or air-borne pathogen transmission are more frequent than expected.
Charlot, Keyne; Romana, Marc; Moeckesch, Berenike; Jumet, Stéphane; Waltz, Xavier; Divialle-Doumdo, Lydia; Hardy-Dessources, Marie-Dominique; Petras, Marie; Tressières, Benoît; Tarer, Vanessa; Hue, Olivier; Etienne-Julan, Maryse; Antoine-Jonville, Sophie; Connes, Philippe
2016-01-01
Vascular resistance and tissue perfusion may be both affected by impaired vascular function and increased blood viscosity. Little is known about the effects of vascular function on the occurrence of painful vaso-occlusive crises (VOC) in children with sickle cell anemia (SCA). The aim of the present study was to determine which side of the balance (blood viscosity or vascular function) is the most deleterious in SCA and increases the risk for frequent hospitalized VOC. Microvascular function, microcirculatory oxygenation and blood viscosity were determined in a group of 22 SCA children/adolescents at steady state and a group of 13 healthy children/adolescents. Univariate analyses demonstrated blunted microvascular reactivity during local thermal heating test and decreased microcirculatory oxygenation in SCA children compared to controls. Multivariate analysis revealed that increased blood viscosity and decreased microcirculatory oxygenation were independent risk factors of frequent VOC in SCA. In contrast, the level of microvascular dysfunction does not predict VOC rate. In conclusion, increased blood viscosity is usually well supported in healthy individuals where vascular function is not impaired. However, in the context of SCA, microvascular function is impaired and any increase of blood viscosity or decrease in microcirculatory oxygenation would increase the risks for frequent VOC. Copyright © 2015 Elsevier Inc. All rights reserved.
Commercialization Issues For Catheter-Based Electrochemical Sensors
NASA Astrophysics Data System (ADS)
Nikolchev, Julian; Gaisford, Scott
1989-08-01
The need for continuous monitoring of key clinical parameters in hospitals is well recognized. Figure 1 shows typical time constants for blood gases, ions and enzymes in response to acute ventilatory changes and interventions. Although it can be seen that relatively low rates of data collection are necessary for many medical measurements, it is also clear that intermittent measurement of P02, PCO2 and pH are not sufficient to provide safe and effective management of the patient. Very frequent or continuous monitoring is often essential. This figure also shows why the emphasis of a large number of research efforts in this country and in Europe and Japan have as their goal the development of continuous blood gas sensors, i.e., sensors that continuously monitor blood pH, partial pressure of oxygen and partial pressure of carbon dioxide. These are three (3) of the most frequent parameters measured in hospitals and the ones having the shortest time constant. Considering that in the United States alone close to 25 million blood gas samples per year are taken from patients, the potential market for continuous monitoring sensors is enormous. The emergence of microelectronics and microfabrication technologies over the past 30 years are now pointing to a possible resolution of the well recognized need for real time monitoring of critically ill patients through catheter-based sensors. Although physicians will always prefer non-invasive monitoring techniques, there are a number of parameters that presently can only be monitored by invasive method. The emerging ability to miniaturize chemical sensors using silicon microfabrication or fiber-optic techniques offer an excellent opportunity to solve this need. In fact, the development of in vivo biomedical sensors with satisfactory performance characteristics has long been considered the ultimate application of these emerging technologies.
Zhang, Yonglong; Patidar, Ashish; Vilar, Enric; Finkelman, Malcolm; Farrington, Ken
2016-01-01
Background Elevated blood endotoxin levels are frequently reported in the dialysis population and are strongly linked with inflammation, a major predictor of mortality. Virtually all studies have employed the Limulus Amoebocyte Lysate (LAL) assay to detect endotoxin. However this assay is not endotoxin-specific and can be activated by (1→3)-β-glucan (BG), a component of fungal cell walls leading to false positive signals. Very few studies have taken account of this. We examined the influence of BG-based activation of the LAL assay on the detection of endotoxemia in this setting. Method We measured plasma endotoxin levels in 50 hemodialysis patients with and without the use of BG-blocking buffers. These buffers inhibit BG activation of the LAL assay to ensure that any signal detected is endotoxin-specific. Blood samples were measured for BG, interleukin-6 (IL-6), tumor necrosis factor-alfa (TNF-α) to examine the association between endotoxin signals, BG and inflammation. Results Endotoxin signals were detected in 50% of patients. On repeat measurement with a BG-blocking buffer, all detected endotoxin signals were extinguished. No patient had detectable endotoxemia. Plasma BG levels were significantly elevated in 58% of patients and were higher in those with detectable endotoxin signals using the LAL assay without BG-blocking buffers (78vs.54pg/mL;p<0.001). Endotoxin signal and BG levels did not correlate with levels of TNF-α or IL-6. Conclusion Use of the LAL assay for blood endotoxin detection in dialysis patients has its limitations due to high blood BG. Endotoxemia frequently reported in non-infected hemodialysis patients may be artefactual due to BG interference. PMID:27764208
Li, Jing; Guo, Weina; Kaltenboeck, Bernhard; Sachse, Konrad; Yang, Yi; Lu, Guangwu; Zhang, Jilei; Luan, Lu; You, Jinfeng; Huang, Ke; Qiu, Haixiang; Wang, Yaoyao; Li, Min; Yang, Zhangping; Wang, Chengming
2016-09-25
To investigate the prevalence and diversity of bovine Chlamydia spp. in cattle, whole blood from dairy and beef cattle in 11 provinces of China (n=2003) and vaginal swabs, whole blood samples, feces, milk samples from cows in a Yangzhou dairy farm (n=108) were examined using genus- and species-specific PCRs. In cattle from 11 provinces, 2.4% (48/2003) of whole-blood samples were positive for Chlamydia spp., and four Chlamydia species (C. pneumoniae, 41.7%, 20/48; C. psittaci, 22.9%, 11/48; C. gallinacea, 20.8%, 10/48; C. pecorum, 6.3%, 3/48) were identified. In a further study on a Yangzhou dairy farm, 64.8% (70/108) of the cows were positive for Chlamydia spp. C. pecorum was the intestinal endemic species (51/51, 100%), and C. gallinacea was the most frequent species in vaginal swabs (24/27, 88.9%), whole blood buffy coats (5/8, 62.5%) and milk (4/6, 66.7%). C. psittaci and C. pneumoniae were infrequently detected. DNA sequencing of the ompA gene demonstrated the presence of multiple in-herd C. pecorum serovars and single C. gallinacea and C. psittaci serovars which were identical with those of poultry from Yangzhou. This is the first report of C. gallinacea and C. pneumoniae in cattle. Further study is required to address the transmission of Chlamydia spp., in particular of C. gallinacea and C. pneumoniae from their natural hosts, and their potential pathogenic effect on health and production of cattle. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Youjin; Zhou, Weiyin; Alter, Blanche P; Wang, Tao; Spellman, Stephen R; Haagenson, Michael; Yeager, Meredith; Lee, Stephanie J; Chanock, Stephen J; Savage, Sharon A; Gadalla, Shahinaz M
2018-06-04
Studies of chromosomal aberrations in blood or bone marrow of patients with Fanconi anemia (FA) have focused on their associations with leukemic transformation. The role of such abnormalities on outcomes after hematopoietic cell transplantation (HCT) is unclear. We used genome-wide single nucleotide polymorphism arrays to identify chromosomal aberrations in pre-HCT blood samples from 73 patients with FA who received unrelated donor HCT for severe aplastic anemia between 1991 and 2007. Outcome data and blood samples were available through the Center for International Blood and Marrow Transplant Research. For survival analyses, we used the Kaplan-Meier estimator to calculate the survival probabilities and the exact log-rank test to compare the survival differences across groups. Chromosomal aberrations were detected in 16 (22%) patients; most frequent were clonal copy loss in chromosome 7 (9.6%), clonal copy gains in the long arm (q) of chromosome 1 (chr1q + ) (8.2%), and clonal or complete copy gains in the q arm of chromosome 3 (chr3q + ) (8.2%). Seven (9.6%) patients had alterations in 3 or more chromosomes. Poor post-HCT overall survival (OS) was noted in patients with chr3q + (P = .04), or those with abnormalities in ≥3 chromosomes (P = .03). The 1-year OS was 0% versus 45% in patients with either alteration versus its absence. No statistically significant differences in 1-year OS were noted in patients carrying deletions in chr7 (29% versus 42%; log-rank P = .74). The study is limited by the small sample size. A larger, prospective study is warranted to validate our findings in light of recent improvement in transplant modalities and outcomes. Copyright © 2018. Published by Elsevier Inc.
Gómez Rioja, Rubén; Martínez Espartosa, Débora; Segovia, Marta; Ibarz, Mercedes; Llopis, María Antonia; Bauça, Josep Miquel; Marzana, Itziar; Barba, Nuria; Ventura, Monserrat; García Del Pino, Isabel; Puente, Juan José; Caballero, Andrea; Gómez, Carolina; García Álvarez, Ana; Alsina, María Jesús; Álvarez, Virtudes
2018-05-05
The stability limit of an analyte in a biological sample can be defined as the time required until a measured property acquires a bias higher than a defined specification. Many studies assessing stability and presenting recommendations of stability limits are available, but differences among them are frequent. The aim of this study was to classify and to grade a set of bibliographic studies on the stability of five common blood measurands and subsequently generate a consensus stability function. First, a bibliographic search was made for stability studies for five analytes in blood: alanine aminotransferase (ALT), glucose, phosphorus, potassium and prostate specific antigen (PSA). The quality of every study was evaluated using an in-house grading tool. Second, the different conditions of stability were uniformly defined and the percent deviation (PD%) over time for each analyte and condition were scattered while unifying studies with similar conditions. From the 37 articles considered as valid, up to 130 experiments were evaluated and 629 PD% data were included (106 for ALT, 180 for glucose, 113 for phosphorus, 145 for potassium and 85 for PSA). Consensus stability equations were established for glucose, potassium, phosphorus and PSA, but not for ALT. Time is the main variable affecting stability in medical laboratory samples. Bibliographic studies differ in recommedations of stability limits mainly because of different specifications for maximum allowable error. Definition of a consensus stability function in specific conditions can help laboratories define stability limits using their own quality specifications.
Ye, Meng; Huang, Tao; Ying, Ying; Li, Jinyun; Yang, Ping; Ni, Chao; Zhou, Chongchang; Chen, Si
2017-01-01
As a tumor suppressor gene, 14-3-3 σ has been reported to be frequently methylated in breast cancer. However, the clinical effect of 14-3-3 σ promoter methylation remains to be verified. This study was performed to assess the clinicopathological significance and diagnostic value of 14-3-3 σ promoter methylation in breast cancer. 14-3-3 σ promoter methylation was found to be notably higher in breast cancer than in benign lesions and normal breast tissue samples. We did not observe that 14-3-3 σ promoter methylation was linked to the age status, tumor grade, clinic stage, lymph node status, histological subtype, ER status, PR status, HER2 status, or overall survival of patients with breast cancer. The combined sensitivity, specificity, AUC (area under the curve), positive likelihood ratios (PLR), negative likelihood ratios (NLR), diagnostic odds ratio (DOR), and post-test probability values (if the pretest probability was 30%) of 14-3-3 σ promoter methylation in blood samples of breast cancer patients vs. healthy subjects were 0.69, 0.99, 0.86, 95, 0.31, 302, and 98%, respectively. Our findings suggest that 14-3-3 σ promoter methylation may be associated with the carcinogenesis of breast cancer and that the use of 14-3-3 σ promoter methylation might represent a useful blood-based biomarker for the clinical diagnosis of breast cancer. PMID:27999208
DeYoung Sullivan, Karen; Vu, Truc; Richardson, Goley; Castillo, Estella; Martinez, Fernando
2015-10-01
Patients with cancer are often dependent on blood transfusions during treatment. Frequent vital sign monitoring during transfusions may interrupt sleep and the patient's ability to ambulate or participate in unit activities. Relying heavily on vital sign findings may also overshadow unmeasurable symptoms of transfusion reaction. The aim of this evidence-based practice initiative was to examine the evidence regarding the optimum frequency of vital sign monitoring for patients undergoing stem cell transplantation receiving blood products and to amend policy and practice to be consistent with the literature. AT A GLANCE : Patients with cancer frequently require transfusion support during treatment.Inconsistencies exist in recommendations for the frequency of vital sign monitoring during transfusion.Examining best practice guidelines suggests that less frequent vital sign monitoring may be appropriate if coupled with thoughtful physiologic assessment.
Bacterial Pathogens Associated with Community-acquired Pneumonia in Children Aged Below Five Years.
Das, Anusmita; Patgiri, Saurav J; Saikia, Lahari; Dowerah, Pritikar; Nath, Reema
2016-03-01
To determine the spectrum of bacterial pathogens causing community-acquired pneumonia in children below 5 years of age. Children aged below 5 years satisfying the WHO criteria for pneumonia, severe pneumonia or very severe pneumonia, and with the presence of lung infiltrates on chest X-ray were enrolled. Two respiratory samples, one for culture and the other for PCR analysis, and a blood sample for culture were collected from every child. Of the 180 samples processed, bacterial pathogens were detected in 64.4%. Streptococcus pneumoniae and Hemophilus influenzae were most frequently detected. The performance of PCR analysis and culture were identical for the typical bacterial pathogens; atypical pathogens were detected by PCR analysis only. S. pneumoniae and H. influenza were the most commonly detected organisms from respiratory secretions of children with community acquired pneumonia.
Refractive index measurement for biomaterial samples by total internal reflection.
Jin, Y L; Chen, J Y; Xu, L; Wang, P N
2006-10-21
The refractive index of biological tissue is a fundamental parameter in applications of optical diagnosis and laser treatments. In the present work, the refractive indices and thermo-optic coefficients of some basic biomaterials, such as blood plasma, haemoglobin solution and lipid membrane, were studied by the method of total internal reflection at the wavelengths of 532 and 632.8 nm that are the most frequently used laser wavelengths in the biomedical field. The effects of the sample concentration and the temperature on refractive index were measured, and empirical relationships were summarized, accompanied by a theoretical explanation based on molecular polarization theory. The results provide some fundamental data for the refractive indices of these biomaterials under variant conditions, and also demonstrate that the total internal reflection method is a feasible and reliable way to measure the refractive indices of biological samples.
Plonis, J; Kalniete, D; Nakazawa-Miklasevica, M; Irmejs, A; Vjaters, E; Gardovskis, J; Miklasevics, E
2015-12-01
Our objective was to determine: 1) whether the checkpoint kinase 2 ( CHEK2 ) del5395 (g.27417113-27422508 del, NC_000022.11) is a founder mutation in the Latvian population, 2) if there is an association between CHEK2 del5395 mutation and cancer risk, and 3) and whether the CHEK2 del5395 mutation impacts cancer predisposition in Chernobyl disaster liquidators (the civil and military personnel who were called upon to deal with consequences of the 1986 nuclear disaster) as well as geriatric populations. We recruited 438 breast cancer patients, 568 colorectal cancer patients, 399 ovarian cancer patients, 419 prostate cancer patients, 526 healthy blood donors, 480 Chernobyl disaster liquidators and 444 geriatric cancer-free participants. DNA samples were isolated from blood samples and subjected to multiplex polymerase chain reaction (PCR). The truncation of del5395 was estimated by fragment size of the multiplex PCR.All groups were compared to the healthy blood donors using Fisher's exact test. All p values were two-sided and the odds ratios (OR) calculated by two-by-two table. In cancer groups, the del5395 mutation was most frequently observed in the ovarian cancer group (1.00%, OR = 1.32). In control groups, the del5395 mutation was most frequent (0.76%) in the healthy donors, which exceeded its frequency in the Chernobyl liquidators group and the geriatric group by 0.01 and 0.08%, respectively. For all groups, the OR appeared to be >1 only in ovarian cancer patients. However, OR rates showed no statistical significance in either cancer or control groups, with the p value fluctuating within the range of 0.39-1.00. The CHEK2 gene del5395 is a founder mutation in the Latvian population, which, however, does not have a direct impact on genetic predisposition toward colorectal, breast, ovarian and prostate cancer.
The Association between ABO and Rh Blood Groups and Risk of Endometriosis in Iranian Women.
Malekzadeh, Farideh; Moini, Ashraf; Amirchaghmaghi, Elham; Daliri, Leila; Akhoond, Mohammad Reza; Talebi, Mehrak; Hosseini, Rihaneh
2018-06-01
Endometriosis is a common gynaecological disease that affects quality of life for women. Several studies have revealed that both environmental and genetic factors contribute to the development of endometriosis. The aim of this study was to investigate the distribution of ABO and Rh blood groups in Iranian women with endometriosis who presented to two referral infertility centers in Tehran, Iran. In this case-control study, women who referred to Royan Institute and Arash Women's Hospital for diagnostic laparoscopy between 2013 and 2014 were assessed. Based on the laparoscopy findings, we categorized the women into two groups: endometriosis and control (women without endometriosis and normal pelvis). Chi-square and logistic regression tests were used for data analysis. In this study, we assessed 433 women, of which 213 patients were assigned to the endometriosis group while the remaining 220 subjects comprised the control group. The most frequent ABO blood group was O (40.6%). The least frequent blood group was AB (4.8%). In terms of Rh blood group, Rh+ (90.1%) was more frequent than Rh- (9.9%). There was no significant correlation between ABO (P=0.091) and Rh (P=0.55) blood groups and risk of endometriosis. Also, there was no significant difference between the two groups with regards to the stage of endometriosis and distribution of ABO and Rh blood groups (P>0.05). Although the O blood group was less dominant in Iranian women with endometriosis, we observed no significant correlation between the risk of endometriosis and the ABO and Rh blood groups. Endometriosis severity was not correlated to any of these blood groups. Copyright© by Royan Institute. All rights reserved.
Kono, Momoko; Hasegawa, Jumpei; Ogawa, Hina; Yoshikawa, Kanae; Ishiwatari, Ayumi; Wakai, Sachiko; Tanabe, Kazunari; Shirakawa, Hiroki
2018-05-01
Tacrolimus is the most commonly used immunosuppressant. Because of its narrow therapeutic range, it is necessary to frequently monitor its concentration. We report the case of a 25-year-old man who underwent kidney transplantation whose tacrolimus concentrations, as measured by an affinity column-mediated immunoassay, were falsely elevated. As we reduced the dose of tacrolimus, the recipient developed T cell-mediated rejection. Using the same blood samples, an enzyme-multiplied immunoassay technique showed that the patient's levels of tacrolimus were extremely low. A further examination indicated that the false increase in the tacrolimus concentration was likely due to an unknown interfering substance. We administered methylprednisolone and antithymocyte-globulin. The patient's serum creatinine level decreased and remained stable after these treatments.
Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P
2014-01-01
Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546
Detection time for THC in oral fluid after frequent cannabis smoking.
Andås, Hilde T; Krabseth, Hege-Merete; Enger, Asle; Marcussen, Bjarne N; Haneborg, An-Magritt; Christophersen, Asbjørg S; Vindenes, Vigdis; Øiestad, Elisabeth L
2014-12-01
The use of oral fluid for detecting drugs of abuse has become increasingly more frequent. Few studies have, however, investigated the detection times for drugs of abuse in oral fluid, compared with that of in urine or in blood. Cannabis is the world's most widely used drug of abuse, and the detection times for cannabis, in different types of matrixes, are therefore important information to the laboratories or institutions performing and evaluating drugs of abuse analyses. It is well known that frequent use of high dosages of cannabis, for longer periods of time, might lead to prolonged detection times for THC-COOH in urine. Cannabis intake is detected in oral fluid as THC, and a positive finding is considered to be a result of recent smoking, although some studies have already reported longer detection times. The aim of this study was to investigate the detection time for THC in oral fluid, collected from drug addicts admitted for detoxification. Findings in oral fluid were compared with findings in urine, among 26 patients admitted to a closed detoxification unit. The study, being the first in doing so, describes the concentration-time profiles for THC in oral fluid among chronic cannabis users, during monitored abstinence, using the Intercept collection kit. The study also includes the concentration-time profiles for creatinine-corrected THC-COOH ratios in urine samples, included to monitor for the possibility of new intakes. THC was detected in oral fluid collected from 11 of the 26 patients in the study. The elimination curves for THC in oral fluid revealed that negative samples could be interspersed among positive samples several days after cessation, whereas the THC-COOH concentrations in urine were decreasing. THC was, in this study, detected in oral fluid for up to 8 days after admission. The study shows that frequent use of high dosages of cannabis may lead to prolonged detection times, and that positive samples can be interspersed among negative samples. These results are of great importance when THC results from oral fluid analyses are to be interpreted.
Effect of glycation on human serum albumin-zinc interaction: a biophysical study.
Iqbal, Sarah; Qais, Faizan Abul; Alam, Md Maroof; Naseem, Imrana
2018-05-01
Zinc deficiency is common in diabetes. However, the cause of this phenomenon is largely unknown. 80% of the absorbed zinc is transported through the blood in association with human serum albumin (HSA). Under persistent hyperglycemia, HSA frequently undergoes non-enzymatic glycation which can affect its structure and metal-binding function. Hence, in this study, we have examined the interaction of zinc with native and glycated HSA. The protein samples were incubated either in the presence or in the absence of physiologically elevated glucose concentration for 21 days. The samples were then analyzed for structural changes and zinc-binding ability using various spectrometric and calorimetric approaches. The study reveals changes in the three-dimensional structure of the protein upon glycation that cause local unfolding of the molecule. Most such regions are localized in subdomain IIA of HSA which plays a key role in zinc binding. This affects zinc interaction with HSA and could in part explain the perturbed zinc distribution in patients with hyperglycemia. The varying degree of HSA glycation in blood could explain the observed heterogeneity pertaining to zinc deficiency among people suffering from diabetes.
Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors.
Carraro, Paolo; Zago, Tatiana; Plebani, Mario
2012-03-01
Few data are available on the nature of errors in the so-called pre-preanalytic phase, the initial steps of the testing process. We therefore sought to evaluate pre-preanalytic errors using a study design that enabled us to observe the initial procedures performed in the ward, from the physician's test request to the delivery of specimens in the clinical laboratory. After a 1-week direct observational phase designed to identify the operating procedures followed in 3 clinical wards, we recorded all nonconformities and errors occurring over a 6-month period. Overall, the study considered 8547 test requests, for which 15 917 blood sample tubes were collected and 52 982 tests undertaken. No significant differences in error rates were found between the observational phase and the overall study period, but underfilling of coagulation tubes was found to occur more frequently in the direct observational phase (P = 0.043). In the overall study period, the frequency of errors was found to be particularly high regarding order transmission [29 916 parts per million (ppm)] and hemolysed samples (2537 ppm). The frequency of patient misidentification was 352 ppm, and the most frequent nonconformities were test requests recorded in the diary without the patient's name and failure to check the patient's identity at the time of blood draw. The data collected in our study confirm the relative frequency of pre-preanalytic errors and underline the need to consensually prepare and adopt effective standard operating procedures in the initial steps of laboratory testing and to monitor compliance with these procedures over time.
What is autologous blood transfusion?
Sansom, A
1993-07-01
The word autologous is Greek in origin. The definition is exact 'autos' means self and 'logus' means relation. Thus, the meaning is 'related to self'. Autologous blood transfusion, which also is referred to frequently but incorrectly and imprecisely as auto transfusion, designates the reinfusion of blood or blood components to the same individual from whom they were taken. Homologous blood is blood or blood components, from another human donor, taken and stored for later transfusion as required.
Microfabricated Multianalyte Sensor Arrays for Metabolic Monitoring
2007-09-01
Introduction Intensive treatment with the goal of maintaining blood glucose concentrations close to the normal range can prevent or delay...the occurrence of diabetic related complications.1 Diabetic patients, therefore, have to frequently monitor their blood glucose levels by drawing... blood necessary for conventional glucose monitoring. The blood data obtained gives no indication of direction or trend of blood sugar levels. Even the
Espeland, Mark A; Probstfield, Jeffery; Hire, Donald; Redmon, J Bruce; Evans, Gregory W; Coday, Mace; Lewis, Cora E; Johnson, Karen C; Wilmoth, Sharon; Bahnson, Judy; Dulin, Michael F; Green, Jennifer B; Knowler, William C; Kitabchi, Abbas; Murillo, Anne L; Osei, Kwame; Rehman, Shakaib U; Cushman, William C
2015-08-01
The relative effectiveness of 3 approaches to blood pressure control-(i) an intensive lifestyle intervention (ILI) focused on weight loss, (ii) frequent goal-based monitoring of blood pressure with pharmacological management, and (iii) education and support-has not been established among overweight and obese adults with type 2 diabetes who are appropriate for each intervention. Participants from the Action for Health in Diabetes (Look AHEAD) and the Action to Control Cardiovascular Risk in Diabetes (ACCORD) cohorts who met criteria for both clinical trials were identified. The proportions of these individuals with systolic blood pressure (SBP) <140 mm Hg from annual standardized assessments over time were compared with generalized estimating equations. Across 4 years among 480 Look AHEAD and 1,129 ACCORD participants with baseline SBPs between 130 and 159 mm Hg, ILI (OR = 1.46; 95% CI = [1.18-1.81]) and frequent goal-based monitoring with pharmacotherapy (OR = 1.51; 95% CI = [1.16-1.97]) yielded higher rates of blood pressure control compared to education and support. The intensive behavioral-based intervention may have been more effective among individuals with body mass index >30 kg/m2, while frequent goal-based monitoring with medication management may be more effective among individuals with lower body mass index (interaction P = 0.047). Among overweight and obese adults with type 2 diabetes, both ILI and frequent goal-based monitoring with pharmacological management can be successful strategies for blood pressure control. clinicaltrials.gov identifiers NCT00017953 (Look AHEAD) and NCT00000620 (ACCORD). © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chovanec, Zdenek; Veverkova, Lenka; Votava, Miroslav; Svoboda, Jiri; Jedlicka, Vaclav; Capov, Ivan
2014-12-01
A variety of methods exist to take samples from surgical site infections for cultivation; however, an unambiguous and suitable method has not yet been defined. The aim of our retrospective non-randomized study was to compare two non-invasive techniques of sampling material for microbiologic analysis in surgical practice. We compared bacteria cultured from samples obtained with the use of the swab technique, defined in our study as the gold standard, with the indirect imprint technique. A cotton-tipped swab (Copan, Brescia, Italy) was used; the imprints were taken using Whatman no. 4 filter paper (Macherey-Nagal, Duren, Germany) cut into 5×5 cm pieces placed on blood agar in a Petri dish. To culture the microorganisms in the microbiology laboratory, we used blood agar, UriSelect 4 medium (Bio-Rad, Marnes-la-Coquette, France), and a medium with sodium chloride (blood agar with salt). After careful debridement, a sample was taken from the incision surface by swab and subsequently the same area of the surface was imprinted onto filter paper. The samples were analyzed in the microbiology laboratory under standard safety precautions. The cultivation results of the two techniques were processed statistically using contingency tables and the McNemar test. Those samples that were simultaneously cultivation-positive by imprint and -negative by swabbing were processed in greater detail. Over the period between October 2008 and March 2013, 177 samples from 70 patients were analyzed. Sampling was carried out from 42 males and 28 females. One hundred forty-six samples were from incisions after operations (21 samples from six patients after operation on the thoracic cavity, 73 samples from 35 patients after operation on the abdominal cavity combined with the gastrointestinal tract, 52 samples from 19 patients with other surgical site infections not included above) and 31 samples from 11 patients with no post-operative infection. One patient had a sample taken both from a post-operative and a non-post-operative site. Coincidently, the most frequent cultivation finding with both techniques was a sterile one (imprint, 62; swab, 50). The microorganism cultivated most frequently after swabbing was Pseudomonas aeruginosa (22 cases), compared with Escherichia coli when the filter paper (imprint) was used (31 cases). The imprint technique was evaluated as more sensitive compared with swabbing (p=0.0001). The κ statistic used to evaluate the concordance between the two techniques was 0.302. Of the 177 samples there were 53 samples simultaneously sterile using the swab and positive in the imprint. In three samples colony- forming units (CFU) were not counted; 22 samples were within the limit of 0-25×10(1) CFU/cm(2), 20 samples within the limit of 25×10(1)-25×10(2) CFU/cm(2), five within the limit of 25×10(2)-25×10(3) CFU/cm(2), and three of more than 25×10(4) CFU/cm(2). The hypothesis of swabbing as a more precise technique was not confirmed. In our study the imprint technique was more sensitive than swabbing; the strength of agreement was fair. We obtained information not only on the type of the microorganism cultured, but also on the number of viable colonies, expressed in CFU/cm(2).
Akmatov, Manas K; Röber, Nadja; Ahrens, Wolfgang; Flesch-Janys, Dieter; Fricke, Julia; Greiser, Halina; Günther, Kathrin; Kaaks, Rudolf; Kemmling, Yvonne; Krone, Bastian; Linseisen, Jakob; Meisinger, Christa; Moebus, Susanne; Obi, Nadia; Guzman, Carlos A; Conrad, Karsten; Pessler, Frank
2017-06-06
We determined the prevalence of anti-nuclear autoantibodies (ANAs) in the German adult population and examined the association between ANAs and cardiovascular and metabolic disorders. We used data and blood samples from the pretest phases of the German National Cohort, obtained from six of the 18 study centers (n = 1199). All centers applied standardized instruments including face-to-face interviews, anthropometric measurements and collection of blood samples. Self-reported histories of diabetes mellitus, heart attack and elevated blood cholesterol and/or lipids were recorded. Height, weight and blood pressure were measured. ANAs were detected using a semi-automated system (AKLIDES®; Medipan GmbH, Dahlewitz, Germany). A positive ANA was defined as a titer ≥ 1:80. ANA were classified as weakly (1:80 or 1:160), moderately (1:320 or 1:640) or strongly (≥1:1280) positive. Specific autoantibodies against nuclear antigens were detected with second-step assays according to the ANA staining pattern. Associations between the assessed disorders and ANA positivity and pattern were examined using sex and age-adjusted mixed-effects logistic regression models. Thirty-three percent (95% confidence interval; 31-36%) of the 1196 participants (measurements could not be obtained from three samples) were ANA positive (titer ≥ 1:80). The proportions of weakly, moderately and strongly positive ANA were 29%, 3.3% and 1.3%, respectively. ANA positivity was more common among women than men across all titers (χ 2 , p = 0.03). ANA positivity, even when stratified according to height of titer or immunofluorescent pattern, was not associated with diabetes, elevated blood cholesterol and/or lipids, obesity or hypertension. Second-step autoantibody assays were positive in 41 of the 83 samples (49%) tested, with anti-DFS70 (n = 13) and anti-dsDNA (n = 7) being most frequent. These subgroups were too small to test for associations with the disorders assessed. The prevalence of ANA positivity in the German general population was similar to values reported from other countries. Contrary to other studies, there was no association with selected self-reported and objectively measured cardiovascular and metabolic variables.
Emergency Physician Estimation of Blood Loss
Ashburn, Jeffery C.; Harrison, Tamara; Ham, James J.; Strote, Jared
2012-01-01
Introduction Emergency physicians (EP) frequently estimate blood loss, which can have implications for clinical care. The objectives of this study were to examine EP accuracy in estimating blood loss on different surfaces and compare attending physician and resident performance. Methods A sample of 56 emergency department (ED) physicians (30 attending physicians and 26 residents) were asked to estimate the amount of moulage blood present in 4 scenarios: 500 mL spilled onto an ED cot; 25 mL spilled onto a 10-pack of 4 × 4-inch gauze; 100 mL on a T-shirt; and 150 mL in a commode filled with water. Standard estimate error (the absolute value of (estimated volume − actual volume)/actual volume × 100) was calculated for each estimate. Results The mean standard error for all estimates was 116% with a range of 0% to 1233%. Only 8% of estimates were within 20% of the true value. Estimates were most accurate for the sheet scenario and worst for the commode scenario. Residents and attending physicians did not perform significantly differently (P > 0.05). Conclusion Emergency department physicians do not estimate blood loss well in a variety of scenarios. Such estimates could potentially be misleading if used in clinical decision making. Clinical experience does not appear to improve estimation ability in this limited study. PMID:22942938
The next chapter in patient blood management: real-time clinical decision support.
Goodnough, Lawrence Tim; Shah, Neil
2014-12-01
Blood transfusion was identified by the American Medical Association as one of the top five most frequently overused therapies. Utilization review has been required by accreditation agencies, but retrospective review has been ineffective due to labor-intense resources applied to only a sampling of transfusion events. Electronic medical records have allowed clinical decision support (CDS) to occur via a best practices alert at the critical decision point concurrently with physician order entry. We review emerging strategies for improving blood utilization. Implementation of CDS at our institution decreased the percentage of transfusions in patients with a hemoglobin level of more than 8 g/dL from 60% to less than 30%. Annual RBC transfusions were reduced by 24%, despite concurrent increases in patient discharge volumes and case mix complexity. This resulted in acquisition costs savings (direct blood product purchase costs) of $6.4 million over 4 years. We have been able to significantly reduce inappropriate blood transfusions and related costs through an educational initiative coupled with real-time CDS. In deriving increased value out of health care, CDS can be applied to a number of overuse measures in laboratory testing, radiology, and therapy such as antibiotics, as outlined by the American Board of Internal Medicine's Choosing Wisely campaign. Copyright© by the American Society for Clinical Pathology.
Ribera, Jordi; Zamora, Lurdes; Morgades, Mireia; Mallo, Mar; Solanes, Neus; Batlle, Montserrat; Vives, Susana; Granada, Isabel; Juncà, Jordi; Malinverni, Roberto; Genescà, Eulàlia; Guàrdia, Ramon; Mercadal, Santiago; Escoda, Lourdes; Martinez-Lopez, Joaquín; Tormo, Mar; Esteve, Jordi; Pratcorona, Marta; Martinez-Losada, Carmen; Solé, Francesc; Feliu, Evarist; Ribera, Josep-Maria
2017-11-01
The outcome of relapsed adult acute lymphoblastic leukemia (ALL) remains dismal despite new therapeutic approaches. Previous studies analyzing relapse samples have shown a high degree of heterogeneity regarding gene alterations without an evident relapse signature. Bone marrow or peripheral blood samples from 31 adult B-cell precursor ALL patients at first relapse, and 21 paired diagnostic samples were analyzed by multiplex ligation probe-dependent amplification (MLPA). Nineteen paired diagnostic and relapse samples of these 21 patients were also analyzed by SNP arrays. A trend to acquire homozygous CDKN2A/B deletions and a significant increase in the number of copy number alterations (CNA) was observed from diagnosis to first relapse. Evolution from an ancestral clone was the main pattern of clonal evolution. Relapse samples were extremely heterogeneous regarding CNA frequencies. However, CDKN2A/B, PAX5, ETV6, ATM, IKZF1, VPREB1, and TP53 deletions and duplications of 1q, 8q, 17q, 21, X/Y PAR1, and Xp were frequently detected at relapse. Duplications of genes involved in cell proliferation, drug resistance and stem cell homeostasis regulation, as well as deletions of KDM6A and STAG2 genes emerged as specific alterations at relapse. Genomics of relapsed adult B-cell precursor ALL is highly heterogeneous, although some recurrent lesions involved in essential pathways deregulation were frequently observed. Selective and simultaneous targeting of these deregulated pathways may improve the results of current salvage therapies. © 2017 Wiley Periodicals, Inc.
... Fatigue Frequent infections Headache Increased thirst and urination High blood pressure Diabetes ... Cushing disease include: Compression fractures in the spine Diabetes High blood pressure Infections Kidney stones Mood or other psychiatric problems
2014-01-01
Background Transfusion-transmissible infections (TTIs) pose a major health risk in Cameroon given the high prevalence of such pathogens and increased demands for blood donations in the local communities. This study aims at establishing the prevalence of commonly encountered TTIs among blood donors and transfusion-related complications among recipients in an urban center of Cameroon. Methods A total of 477 blood donors and 83 blood recipients were recruited by consecutive sampling at the Laquintinie Hospital in Douala (LHD), Cameroon. Serum samples from blood donors were tested by quantitative enzyme-linked immunosorbent assays (ELISA) and/or using various Rapid diagnostic test (RDT) for presence of Hepatits B (HBV) viral antigens, and antibodies to human immunodeficiency (HIV-1/2), Hepatits B (HCV) and Treponema pallidum. Recipient’s medical records were also analyzed for possible transfusion-associated complications. Results The male/female sex ratio of the blood donors was 4/1 with a mean age of 30.2 (Sd = 8.3) years. Of all blood donors, 64/467 (13.7%) were infected by at least one of the four TTIs. Infected volunteer donors represented 8.3% while infected family donors comprised 14.3% of the donor population. The prevalence of HCV, HIV, HBV and T. pallidum were 1.3%, 1.8%, 3.5%, and 8.1%, respectively. More than half of the blood recipients were female (78.3%) and the mean age was 20.6 (SD = 16.1) years. The causes of severe anemia indicative of transfusion in recipients varied with wards (postpartum hemorrhage, caesarean section, uterine or cervical lacerations, abortions, urinary tract infections, severe malaria, vaso-occlusive attacks, wounds and gastrointestinal bleeding). The most frequent complications were chills and hematuria, which represented 46.1% of all observed complications. Other complications such as nausea, vomiting, jaundice, sudden diarrhea, anxiety, tachycardia, or hyperthermia were also found in recipients. Three cases of deaths occurred during the study, including a girl of less than one year. Conclusion This study confirms the presence of blood-borne infectious diseases in blood donors at the LHD, identifying T. pallidum as the greatest threat to blood safety in the region, and hematuria as the most common immunological complications in blood recipients. PMID:24517107
K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare
2012-01-01
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.
K3EDTA Vacuum Tubes Validation for Routine Hematological Testing
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare
2012-01-01
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K3EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K3EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests. PMID:22888448
Calibration Experiments Conducted for Noninvasive Blood Glucose Sensing Through the Eye
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Bockle, Stefan; Suh, Kwang I.; Rovati, Luigi L.
2004-01-01
There are more than 16 million diabetics in the United States and more than 100 million worldwide. Diabetes can lead to severe complications over time such as blindness, renal and cardiovascular diseases, and peripheral neuropathy in the limbs. Poor blood circulation in diabetics can lead to gangrene and the subsequent amputation of extremities. In addition, this pathology is the fourth leading cause of death in the United States. The most effective way to manage diabetes is frequent blood glucose monitoring performed by the patients themselves. However, because of pain, inconvenience, and the fear of developing infections from finger-prick blood tests or implants, many patients monitor their blood glucose levels less frequently than is recommended by their physicians. Therefore, a noninvasive, painless, and convenient method to monitor blood glucose would greatly benefit diabetics. Likewise, detecting, preventing, and treating the untoward effects of prolonged space travel (e.g., a human mission to Mars) in real-time requires the development of noninvasive diagnostic technologies that are compact and powerful. As a "window to the body," the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and to help develop preventative and therapeutic countermeasures early. The noninvasive feature of these technologies permits frequent repetition of tests, enabling an evaluation of the response to therapy.
Fink, A E; Fink, G; Wilson, H; Bennie, J; Carroll, S; Dick, H
1992-01-01
The effect of lactation on menstrual cycles, ovulation and conception was studied in a group of non-contracepting Amerindian Mopan Mayan women. Anthropological observations of relevant events were made over a 21-month period. Blood samples were assayed to determine the plasma concentrations of prolactin, luteinising hormone, follicle stimulating hormone, human chorionic gonadotrophin, placental lactogen, oestrogen, progesterone and cortisol. The data show that: frequent and prolonged breast-feeding was associated with a marked increase in plasma prolactin concentrations to levels similar to those in lactating Gaing but higher than those in lactating Scottish women; ovulatory menstrual cycles and pregnancy occurred during frequent lactation; in lactating menstruating women there was an inverse correlation between fat weight and months post-partum. These data suggest that other factors as well as suckling account for the effects of lactation on fecundity.
Zhang, Tao; Gan, Zhiwei; Gao, Chuanzi; Ma, Ling; Li, Yanxi; Li, Xiao; Sun, Hongwen
2016-09-14
In this study, acesulfame (ACE), saccharin (SAC) and cyclamate (CYC) were found in all paired urine and blood samples collected from healthy adults, with mean values of 4070, 918 and 628 ng mL(-1), respectively, in urine and 9.03, 20.4 and 0.72 ng mL(-1), respectively, in blood. SAC (mean: 84.4 ng g(-1)) and CYC (4.29 ng g(-1)) were detectable in all liver samples collected from liver cancer patients, while ACE was less frequently detected. Aspartame (ASP) was not found in any analyzed human sample, which can be explained by the fact that this chemical metabolized rapidly in the human body. Among all adults, significantly positive correlations between SAC and CYC levels were observed (p < 0.001), regardless of human matrices. Nevertheless, no significant correlations between concentrations of SAC (or CYC) and ACE were found in any of the human matrices. Our results suggest that human exposure to SAC and CYC is related, whereas ACE originates from a discrete source. Females (or young adults) were exposed to higher levels of SAC and CYC than males (or elderly). The mean renal clearance of SAC was 730 mL per day per kg in adults, which was significantly (p < 0.001) lower than those for CYC (10 800 mL per day per kg) and ACE (10 300 mL per day per kg). The average total daily intake of SAC and ACE was 9.27 and 33.8 μg per kg bw per day, respectively.
Murcia-Aranguren, Martha I; Gómez-Marin, Jorge E; Alvarado, Fernando S; Bustillo, José G; de Mendivelson, Ellen; Gómez, Bertha; León, Clara I; Triana, William A; Vargas, Erwing A; Rodríguez, Edgar
2001-01-01
Background The prevalence of infections by Mycobacterium tuberculosis and non-tuberculous Mycobacterium species in the HIV-infected patient population in Colombia was uncertain despite some pilot studies. We determined the frequency of isolation of Mycobacterium tuberculosis and of non-tuberculous Mycobacterium species in diverse body fluids of HIV-infected patients in Bogota, Colombia. Methods Patients who attended the three major HIV/AIDS healthcare centres in Bogota were prospectively studied over a six month period. A total of 286 patients were enrolled, 20% of them were hospitalized at some point during the study. Sixty four percent (64%) were classified as stage C, 25% as stage B, and 11% as stage A (CDC staging system, 1993). A total of 1,622 clinical samples (mostly paired samples of blood, sputum, stool, and urine) were processed for acid-fast bacilli (AFB) stain and culture. Results Overall 43 of 1,622 cultures (2.6%) were positive for mycobacteria. Twenty-two sputum samples were positive. Four patients were diagnosed with M. tuberculosis (1.4%). All isolates of M. tuberculosis were sensitive to common anti-tuberculous drugs. M. avium was isolated in thirteen patients (4.5%), but only in three of them the cultures originated from blood. The other isolates were obtained from stool, urine or sputum samples. In three cases, direct AFB smears of blood were positive. Two patients presented simultaneously with M. tuberculosis and M. avium. Conclusions Non-tuberculous Mycobacterium infections are frequent in HIV infected patients in Bogota. The diagnostic sensitivity for infection with tuberculous and non-tuberculous mycobacteria can be increased when diverse body fluids are processed from each patient. PMID:11722797
PREVALENCE OF GENETIC SUSCEPTIBILITY FOR CELIAC DISEASE IN BLOOD DONORS IN SÃO PAULO, BRAZIL.
Muniz, Janaína Guilhem; Sdepanian, Vera Lucia; Fagundes, Ulysses
2016-01-01
Celiac disease is a permanent intolerance induced by gluten, which is expressed by T-cell mediated enteropathy, and has a high prevalence in the general population. There is evidence of a strong genetic predisposition to celiac disease. To determine the prevalence of genetic markers HLA-DQ2 and HLA-DQ8 in blood donors from São Paulo and measure human recombinant tissue transglutaminase antibody IgA class in HLA-DQ2 and HLA-DQ8 positive donors. A total of 404 blood donors from São Paulo city and Jundiaí were included in the study and signed the informed consent form. Information regarding diarrhea, constipation and abdominal pain in the last 3 months was collected. Determination of HLADQ2 and HLADQ8 alleles was performed in all participants and human recombinant tissue transglutaminase antibody class IgA was measured only in blood donors who presentedDQ2 and/or DQ8. HLADQ2 and/or HLADQ8 were positive in 49% (198/404) of subjects. Positive samples were associated with alleles DR3, DR4, DR7, DR11 and DR12. The most frequent genotype was DR4-DQ8, which was present in 13.6% of samples, followed by genotypes DR3-DQ2 and DR7-DQ2 with DQB1*02 in heterozygous, which were present in 10.4% and 8.7%, respectively. Eleven out of 198 positive donors (5%) were positive to human tissue transglutaminase test. We observed a high prevalence of genetic markers for celiac disease, HLA-DQ2 and HLA-DQ8, in blood donors from São Paulo, similar to prevalence described in Europe. These findings show that the prevalence of celiac disease should not be rare in our country, but underdiagnosed.
Fischer, Cristine Dossin Bastos; Ikuta, Nilo; Canal, Cláudio Wageck; Makiejczuk, Aline; Allgayer, Mariangela da Costa; Cardoso, Cristine Hoffmeister; Lehmann, Fernanda Kieling; Fonseca, André Salvador Kazantzi; Lunge, Vagner Ricardo
2013-12-01
Canine distemper virus (CDV) is the cause of a severe and highly contagious disease in dogs. Practical diagnosis of canine distemper based on clinical signs and laboratory tests are required to confirm CDV infection. The present study aimed to develop a molecular assay to detect and differentiate field and vaccine CDV strains. Reverse transcription followed by nested real time polymerase chain reaction (RT-nqPCR) was developed, which exhibited analytical specificity (all the samples from healthy dogs and other canine infectious agents were not incorrectly detected) and sensitivity (all replicates of a vaccine strain were positive up to the 3125-fold dilution - 10(0.7) TCID50). RT-nqPCR was validated for CDV detection on different clinical samples (blood, urine, rectal and conjunctival swabs) of 103 animals suspected to have distemper. A total of 53 animals were found to be positive based on RT-nqPCR in at least one clinical sample. Blood resulted in more positive samples (50 out of 53, 94.3%), followed by urine (44/53, 83.0%), rectal (38/53, 71%) and conjunctival (27/53, 50.9%) swabs. A commercial immunochromatography (IC) assay had detected CDV in only 30 conjunctival samples of these positive dogs. Nucleoprotein (NC) gene sequencing of 25 samples demonstrated that 23 of them were closer to other Brazilian field strains and the remaining two to vaccine strains. A single nucleotide sequences difference, which creates an Msp I restriction enzyme digestion, was used to differentiate between field and vaccine CDV strains by restriction fragment length polymorphism (RFLP) analysis. The complete assay was more sensitive than was IC for the detection of CDV. Blood was the more frequently positive specimen and the addition of a restriction enzyme step allowed the differentiation of vaccine and Brazilian field strains. Copyright © 2013 Elsevier B.V. All rights reserved.
Kaplan, H S
2005-11-01
Safety and reliability in blood transfusion are not static, but are dynamic non-events. Since performance deviations continually occur in complex systems, their detection and correction must be accomplished over and over again. Non-conformance must be detected early enough to allow for recovery or mitigation. Near-miss events afford early detection of possible system weaknesses and provide an early chance at correction. National event reporting systems, both voluntary and involuntary, have begun to include near-miss reporting in their classification schemes, raising awareness for their detection. MERS-TM is a voluntary safety reporting initiative in transfusion. Currently 22 hospitals submit reports anonymously to a central database which supports analysis of a hospital's own data and that of an aggregate database. The system encourages reporting of near-miss events, where the patient is protected from receiving an unsuitable or incorrect blood component due to a planned or unplanned recovery step. MERS-TM data suggest approximately 90% of events are near-misses, with 10% caught after issue but before transfusion. Near-miss reporting may increase total reports ten-fold. The ratio of near-misses to events with harm is 339:1, consistent with other industries' ratio of 300:1, which has been proposed as a measure of reporting in event reporting systems. Use of a risk matrix and an event's relation to protective barriers allow prioritization of these events. Near-misses recovered by planned barriers occur ten times more frequently then unplanned recoveries. A bedside check of the patient's identity with that on the blood component is an essential, final barrier. How the typical two person check is performed, is critical. Even properly done, this check is ineffective against sampling and testing errors. Blood testing at bedside just prior to transfusion minimizes the risk of such upstream events. However, even with simple and well designed devices, training may be a critical issue. Sample errors account for more than half of reported events. The most dangerous miscollection is a blood sample passing acceptance with no previous patient results for comparison. Bar code labels or collection of a second sample may counter this upstream vulnerability. Further upstream barriers have been proposed to counter the precariousness of urgent blood sample collection in a changing unstable situation. One, a linking device, allows safer labeling of tubes away from the bedside, the second, a forcing function, prevents omission of critical patient identification steps. Errors in the blood bank itself account for 15% of errors with a high potential severity. In one such event, a component incorrectly issued, but safely detected prior to transfusion, focused attention on multitasking's contribution to laboratory error. In sum, use of near-miss information, by enhancing barriers supporting error prevention and mitigation, increases our capacity to get the right blood to the right patient.
Hostile behavior during marital conflict alters pituitary and adrenal hormones.
Malarkey, W B; Kiecolt-Glaser, J K; Pearl, D; Glaser, R
1994-01-01
We evaluated hormonal changes and problem-solving behaviors in 90 newlywed couples who were admitted to a hospital research unit for 24 hours. The subjects were selected on the basis of stringent mental and physical health criteria, and admissions were scheduled during the follicular phase of the woman's menstrual cycle. For frequent, unobtrusive endocrine sampling during the interaction tasks, a long polyethylene tube was attached to a heparin well, allowing nurses to draw blood samples at set intervals, out of subjects' sight. Five blood samples were obtained before, during, and after a 30-minute structured problem-solving or conflict task. The conflict session was recorded on videotapes that were later scored for problem-solving behaviors using the Marital Interaction Coding System (MICS). Marital conflict and MICS-coded hostile or negative behavior during conflict was closely linked to changes in serum hormonal levels across five of the six hormones we studied, in spite of the high marital satisfaction of our newlywed couples and the healthy lifestyles demanded by our exclusion criteria. Hostile behavior was associated with decreased levels of prolactin (PRL) and increases in epinephrine (EPI), norepinephrine (NEPI), ACTH, and growth hormone (GH), but not cortisol. These data suggest that the endocrine system may be an important mediator between personal relationships and health.
An epidemiological survey of Theileria infections in small ruminants in central China.
Li, Youquan; Zhang, Xiao; Liu, Zhijie; Chen, Ze; Yang, Jifei; He, Haining; Guan, Guiquan; Liu, Aihong; Ren, Qiaoyun; Niu, Qingli; Liu, Junlong; Luo, Jianxun; Yin, Hong
2014-02-24
Here, we conducted an epidemiological study in five regions in central China to assess the impact of theileriosis on small ruminants. PCR analysis and microscopic evaluations of blood smears to detect ovine and caprine theileriosis was conducted, in which 256 blood samples and 250 ticks were collected from sheep and goats, and tested for Theileria uilenbergi, T. luwenshuni, and T. ovis. The 18S rRNA gene sequences were deduced from positive samples and used for phylogenetic analysis. The results showed that T. luwenshuni was found most frequently in the five investigated regions and the prevalence of T. luwenshuni was found to be very high by PCR analysis. In contrast, T. uilenbergi and T. ovis infections were not detected in these regions. Phylogenetic tree analysis showed that all of the newly isolated Theileria spp. was in the same clade as T. luwenshuni. Haemaphysalis longicornis, which can transmit T. luwenshuni, was also detected in the sampled sheep and goats in these regions. Our results provide important data to increase the understanding of the epidemiology of ovine and caprine theileriosis, and will aid in the implementation of measures to control theileriosis transmission to small ruminants in central China. Copyright © 2013. Published by Elsevier B.V.
Psychoactive substances in seriously injured drivers in Denmark.
Wiese Simonsen, K; Steentoft, A; Bernhoft, I M; Hels, T; Rasmussen, B S; Linnet, K
2013-01-10
This study assesses the presence of a number of psychoactive substances, including alcohol, based on blood samples from 840 seriously injured drivers admitted to five selected hospitals located in five different regions of Denmark. The study was a part of the EU 6th framework program DRUID (Driving Under the Influence of Drugs, Alcohol and Medicines). Blood samples were screened for 30 illegal and legal psychoactive substances and metabolites as well as ethanol. Danish legal limits were used to evaluate the frequency of drivers violating the Danish legislation while limit of quantification (LOQ) was used for monitoring positive drivers. Tramadol is not included in the Danish legislation therefore the general cut off, as decided in the DRUID project was used. Overall, ethanol (18%) was the most frequently identified compound (alone or in combination with other drugs) exceeding the legal limit, which is 0.53g/l in Denmark. The percentage of seriously injured drivers testing positive for medicinal drugs at levels above the Danish legal limit was 6.8%. Benzodiazepines and Z-drugs (6.4%) comprised the majority of this group. One or more illegal drugs (primarily amphetamines and cannabis) were found to be above the Danish legal limit in 4.9% of injured drivers. Young men (median age 31 years) were over-represented among injured drivers who violated Danish law for alcohol and drugs. Diazepam (4.4%), tramadol (3.2%), and clonazepam (3.0%) were the medicinal drugs most frequently detected at levels above LOQ, whereas amphetamines (5.4%) (amphetamine [5.2%] and methamphetamine [1.5%]), tetrahydrocannabinol (3.7%), and cocaine (3.3%), including the metabolite benzoylecgonine, were the most frequently detected illegal drugs. A driver could be positive for more than one substance; therefore, percentages are not mutually exclusive. Poly-drug use was observed in 112 (13%) seriously injured drivers. Tramadol was detected above DRUID cutoffs in 2.1% of seriously injured drivers. This is 3.5 times that observed in a Danish survey of randomly selected drivers. Moreover, illegal and medicinal drug levels above the Danish legal limit were present more than 10 times as frequently as in injured drivers, whereas ethanol was present more than 30 times as frequently than in randomly selected drivers. The results indicate that there is an increased risk in traffic when driving under the influence of psychoactive drugs, especially alcohol in young male drivers. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Combinatorial Screening Of Inorganic And Organometallic Materials
Li, Yi , Li, Jing , Britton, Ted W.
2002-06-25
A method for differentiating and enumerating nucleated red blood cells in a blood sample is described. The method includes the steps of lysing red blood cells of a blood sample with a lytic reagent, measuring nucleated blood cells by DC impedance measurement in a non-focused flow aperture, differentiating nucleated red blood cells from other cell types, and reporting nucleated red blood cells in the blood sample. The method further includes subtracting nucleated red blood cells and other interference materials from the count of remaining blood cells, and reporting a corrected white blood cell count of the blood sample. Additionally, the method further includes measuring spectrophotometric absorbance of the sample mixture at a predetermined wavelength of a hemoglobin chromogen formed upon lysing the blood sample, and reporting hemoglobin concentration of the blood sample.
Gevaert, D; Nelis, J; Verhaeghe, B
1991-09-01
Polyuria-polydipsia is a frequent observation in pigeons with salmonellosis. These are accompanied by a decreased albumin/globulin ratio, increased creatinine and haptoglobin concentrations, and decrease in the chloride concentration in the blood plasma. The urine was found to have a low density with red and white blood cells frequently present in the sediment. A water deprivation test was conducted on three animals: polyuria disappeared and plasma urea increased significantly.
Institóris, László; Árok, Zsófia; Seprenyi, Katalin; Varga, Tibor; Sára-Klausz, Gabriella; Keller, Éva; Tóth, Réka A; Sala, Leonardo; Kereszty, Éva; Róna, Kálmán
2015-03-01
Identification of abuse and frequency patterns of stimulant designer drugs (SDDs) provides important information for their risk assessment and legislative control. In the present study urine and/or blood samples of suspected drug users in criminal cases were analysed by GC-MS for 38 SDDs, and for the most frequent illicit and psychoactive licit drugs in Hungary. Between July 2012 and June 2013, 2744 suspected drug users were sampled in Budapest and during 2012 and 2013, 774 persons were sampled in South-East Hungary (Csongrád County - neighbour the Romanian and Serbian borders). In Budapest 71.4% of cases, and in South-East Hungary 61% of cases were positive for at least one substance. Pentedrone was the most frequent SDD in both regions; however, the frequency distribution of the remaining drugs was highly diverse. SDDs were frequently present in combination with other drugs - generally with amphetamine or other stimulants, cannabis and/or benzodiazepines. The quarterly distribution of positive samples indicated remarkable seasonal changes in the frequency and pattern of consumption. Substances placed on the list of illicit drugs (mephedrone, 4-fluoro-amphetamine, MDPV, methylone, 4-MEC) showed a subsequent drop in frequency and were replaced by other SDDs (pentedrone, 3-MMC, methiopropamine, etc.). Newly identified compounds from seized materials were added to the list of new psychoactive substances ("Schedule C"). While the risk assessment of substances listed in Schedule C has to be performed within 2 years after scheduling, continuous monitoring of their presence and frequency among drug users is essential. In summary, our results suggest which substances should be dropped from the list of SDDs measured in biological samples; while the appearance of new substances from seized materials indicate the need for developing adequate standard analytical methods. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Relevance of blood groups in transfusion of sickle cell disease patients.
Noizat-Pirenne, France
2013-03-01
Blood groups are clinically significant in sickle cell disease (SCD) as transfusion remains a key treatment in this pathology. The occurrence of a delayed haemolytic transfusion reaction (DHTR) is not rare and is a life-threatening event. The main cause of DHTR is the production of alloantibodies against red blood cell antigens. The high rate of alloimmunization in SCD patients is mainly due to the differences of red blood groups between patients of African descent, and the frequently Caucasian donors. From an immuno-haematological point of view, DHTR in SCD patients has specific features: classical antibodies known to be haemolytic can be encountered, but otherwise non significant antibodies, autoantibodies and antibodies related to partial and rare blood groups are also frequently found in individuals of African descent. In some cases, there are no detectable antibodies. As alloimmunization remains the main cause of DHTR, it is extremely important to promote blood donation by individuals of African ancestry to make appropriate blood available. Copyright © 2012 Académie des sciences. Published by Elsevier SAS. All rights reserved.
Heinemann, Lutz; Boecker, Dirk
2011-01-01
Today, lancing fingertips or alternative sites for obtaining a blood sample for self-monitoring of blood glucose (SMBG) is a standard procedure for most patients with diabetes. The need for frequent lancing and associated discomfort and pain can be seen as a key hurdle for patients to comply with SMBG regimens. This article provides an overview of the status quo and future of lancing, focusing on key areas for future developments driven by customer and market needs. We also review technical issues and provide a background for possible improvements. The act of puncturing the skin with a lancet to obtain a blood sample seems to remain the standard procedure for the foreseeable future, because alternate ways of providing a blood sample have not demonstrated overall superiority (e.g., with laser technology). Other methods, which avoid lancing entirely, have also not gained broad market acceptance (e.g., minimally invasive continuous glucose monitoring) or not shown technical viability (e.g., noninvasive glucose monitoring). In relation to blood glucose (BG) meters and test strips, lancing has been a “stepchild” with regards to commercial attention and development efforts. Nevertheless, significant technological improvements have been made in this field to address key customer needs, including better performance (regarding pain, wound healing, and long-term sensitivity), reduced cost, and higher integration with other components of BG monitoring (e.g., integration of the lancing device with the glucose monitor). From a technical perspective, it is apparent that highly comfortable lancing can be accomplished; however, this still requires fairly advanced and complex devices. New developments are necessary to achieve this level of sophistication and performance with less intricate and costly system designs. Manufacturers' motivation to pursue these developments is compromised by the fact that they might not recoup their development cost on commercial advanced lancing systems through direct profits, but only through its positive influence on adherence and increased more profitable sensor utilization. We believe that two main driving forces will continue to push the evolution of lancing and sampling technology: (1) the need for maximum lancing comfort and (2) the advent of fully integrated systems, realizing a device in which all steps for SMBG are incorporated, thus providing a “one-step” experience. Rendering lancing a “nonissue” will eliminate a key barrier to adherence with appropriate SMBG regimens. Providing sophisticated lancing devices that allow the highest level of comfort and/or seamless blood sampling is key to improving user acceptance. This may have a greater impact on metabolic control than many of the new and expensive antidiabetic drugs. PMID:21880240
Pedersen, Anders Just; Dalsgaard, Petur Weihe; Rode, Andrej Jaroslav; Rasmussen, Brian Schou; Müller, Irene Breum; Johansen, Sys Stybe; Linnet, Kristian
2013-07-01
A broad forensic screening method for 256 analytes in whole blood based on a fully automated SPE robotic extraction and ultra-high-performance liquid chromatography (UHPLC) with TOF-MS with data-independent acquisition has been developed. The limit of identification was evaluated for all 256 compounds and 95 of these compounds were validated with regard to matrix effects, extraction recovery, and process efficiency. The limit of identification ranged from 0.001 to 0.1 mg/kg, and the process efficiency exceeded 50% for 73 of the 95 analytes. As an example of application, 1335 forensic traffic cases were analyzed with the presented screening method. Of these, 992 cases (74%) were positive for one or more traffic-relevant drugs above the Danish legal limits. Commonly abused drugs such as amphetamine, cocaine, and frequent types of benzodiazepines were the major findings. Nineteen less frequently encountered drugs were detected e.g. buprenorphine, butylone, cathine, fentanyl, lysergic acid diethylamide, m-chlorophenylpiperazine, 3,4-methylenedioxypyrovalerone, mephedrone, 4-methylamphetamine, p-fluoroamphetamine, and p-methoxy-N-methylamphetamine. In conclusion, using UHPLC-TOF-MS screening with data-independent acquisition resulted in the detection of common drugs of abuse as well as new designer drugs and more rarely occurring drugs. Thus, TOF-MS screening of blood samples constitutes a practical way for screening traffic cases, with the exception of δ-9-tetrahydrocannabinol, which should be handled in a separate method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Prevalence of cardiovascular risk factors in adolescents].
Romanzini, Marcelo; Reichert, Felipe Fossati; Lopes, Adair da Silva; Petroski, Edio Luiz; de Farias Júnior, José Cazuza
2008-11-01
The aim of this study was to determine the prevalence of cardiovascular risk factors in adolescents and to verify its association with age and gender. 644 high school students from public schools in the city of Londrina, Paraná State, Brazil, participated in the study. A two-step sampling process was used. Behavioral risk factors (physical inactivity, inadequate consumption of fruits and vegetables, and smoking) and biological risk factors (overweight and high blood pressure) were investigated. Nearly 90% of adolescents showed at least one risk factor. Inadequate consumption of fruits (56.7%) and vegetables (43.9%) and physical inactivity (39.2%) were the most prevalent risk factors. Prevalence rates for high blood pressure and overweight were 18.6 and 12.7%, respectively. Cardiovascular risk factors were more frequent among boys (PR = 1.20; 95%CI = 1.01-1.42). In conclusion, cardiovascular risk factors are a prevalent health issue among students in the city of Londrina.
Fink, Susanne; Tsai, Ming-Han; Schnitzler, Paul; Zeier, Martin; Dreger, Peter; Wuchter, Patrick; Bulut, Olcay C; Behrends, Uta; Delecluse, Henri-Jacques
2017-01-01
Transplant recipients frequently exhibit an increased Epstein-Barr virus (EBV) load in the peripheral blood. Here, we quantitated the EBV-infected cells in the peripheral blood of these patients and defined the mode of viral infection, latent or lytic. These data indicated that there is no strong correlation between the number of infected cells and the EBV load (EBVL). This can be explained by a highly variable number of EBV copies per infected cell and by lytic replication in some cells. The plasma of these patients did not contain any free infectious viruses, but contained nevertheless EBV DNA, sometimes in large amounts, that probably originates from cell debris and contributed to the total EBVL. Some of the investigated samples carried a highly variable number of infected cells in active latency, characterized by an expression of the Epstein-Barr nuclear antigens (EBNA2) protein. However, a third of the samples expressed neither EBNA2 nor lytic proteins. Patients with an increased EBVL represent a heterogeneous group of patients whose infection cannot be characterized by this method alone. Precise characterization of the origin of an increased EBVL, in particular, in terms of the number of EBV-infected cells, requires additional investigations including the number of EBV-encoded small RNA-positive cells. © 2016 Steunstichting ESOT.
Rambousková, Jolana; Dlouhý, Pavel; Krízová, Eva; Procházka, Bohumír; Hrncírová, Dana; Andel, Michal
2009-01-01
To compare maternal health behaviors, maternal nutritional status, and infant size at birth of Romas and non-Romas in the Czech Republic. Maternal interviews and food frequency questionnaire, maternal blood samples, physical measurements of mothers and infants. Hospital, maternal/child care center; 2-4 days postpartum. 76 Roma mothers and 151 mothers from the majority population. Infant length/weight; maternal height/weight; weight gain during pregnancy; duration of pregnancy; maternal smoking habits; dietary intake; use of food supplements during pregnancy; and maternal blood levels of folate, beta-carotene, retinol, and alpha-tocopherol. Comparison of ethnic groups by 2-sample Wilcoxon test, chi-square, Fischer's exact test, relative risk, and analysis of variance (ANOVA). Pregnancy duration was about 1 week shorter in Roma women (P < .001), and their infants had lower birth weight (P < .001) and shorter length (P < .001). Prevalence of smoking was significantly higher among Roma mothers (P < .001). Roma women used food supplements less frequently than non-Roma women (P < .001) and had significantly lower mean blood concentrations of folate (P < .001), beta-carotene (P < .001), retinol (P < .02), and alpha-tocopherol (P < .02). The nutritional status of Roma mothers is worse than that of mothers from the majority Czech population. The dietary and smoking habits of pregnant Roma women should be of special concern to family doctors, obstetricians, nutrition educators, and social workers.
Sidhu, Shailpreet K; Malhotra, Sita; Devi, Pushpa; Tuli, Arpandeep K
2016-12-01
Coagulase negative Staphylococcus (CoNS) is frequently isolated from blood cultures but their significance is difficult to interpret. CoNS bacteria which are often previously dismissed as culture contaminants are attracting greater importance as true pathogens in the past decades. Clinical evaluation of these isolates suggests that although there is a relative increase of CoNS associated bloodstream infections in recent years, the microorganisms still remain the most common contaminants in blood cultures. The objective of this study was to determine the significance of CoNS isolated from blood cultures. A retrospective study was conducted to evaluate the rate of contamination in blood cultures in a tertiary care hospital. The paired specimens of blood were cultured using conventional culture methods and the isolates of coagulase negative staphylococci were identified by standard methodology. Clinical data, laboratory indices, microbiological parameters and patient characteristics were analyzed. Of 3503 blood samples, CoNS were isolated from blood culture of 307 patients (8.76%). The isolates were reported as true pathogens of bloodstream infections in only 74 out of 307 cases (24.1%). In the vast majority, 212 of 307 (69.0%), they were mere blood culture contaminants and reported as insignificant/contaminant. Determining whether a growth in the blood culture is a pathogen or a contaminant is a critical issue and multiple parameters have to be considered before arriving at a conclusion. Ideally, the molecular approach is for the most part a consistent method in determining the significant isolates of CoNS. However, in countries with inadequate resources, species identification and antibiogram tests are recommended when determining significance of these isolates.
Validation of SCT Methylation as a Hallmark Biomarker for Lung Cancers.
Zhang, Yu-An; Ma, Xiaotu; Sathe, Adwait; Fujimoto, Junya; Wistuba, Ignacio; Lam, Stephen; Yatabe, Yasushi; Wang, Yi-Wei; Stastny, Victor; Gao, Boning; Larsen, Jill E; Girard, Luc; Liu, Xiaoyun; Song, Kai; Behrens, Carmen; Kalhor, Neda; Xie, Yang; Zhang, Michael Q; Minna, John D; Gazdar, Adi F
2016-03-01
The human secretin gene (SCT) encodes secretin, a hormone with limited tissue distribution. Analysis of the 450k methylation array data in The Cancer Genome Atlas (TCGA) indicated that the SCT promoter region is differentially hypermethylated in lung cancer. Our purpose was to validate SCT methylation as a potential biomarker for lung cancer. We analyzed data from TCGA and developed and applied SCT-specific bisulfite DNA sequencing and quantitative methylation-specific polymerase chain reaction assays. The analyses of TCGA 450K data for 801 samples showed that SCT hypermethylation has an area under the curve (AUC) value greater than 0.98 that can be used to distinguish lung adenocarcinomas or squamous cell carcinomas from nonmalignant lung tissue. Bisulfite sequencing of lung cancer cell lines and normal blood cells allowed us to confirm that SCT methylation is highly discriminative. By applying a quantitative methylation-specific polymerase chain reaction assay, we found that SCT hypermethylation is frequently detected in all major subtypes of malignant non-small cell lung cancer (AUC = 0.92, n = 108) and small cell lung cancer (AUC = 0.93, n = 40) but is less frequent in lung carcinoids (AUC = 0.54, n = 20). SCT hypermethylation appeared in samples of lung carcinoma in situ during multistage pathogenesis and increased in invasive samples. Further analyses of TCGA 450k data showed that SCT hypermethylation is highly discriminative in most other types of malignant tumors but less frequent in low-grade malignant tumors. The only normal tissue with a high level of methylation was the placenta. Our findings demonstrated that SCT methylation is a highly discriminative biomarker for lung and other malignant tumors, is less frequent in low-grade malignant tumors (including lung carcinoids), and appears at the carcinoma in situ stage. Copyright © 2015 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
The effect of refrigeration of bone marrow and peripheral blood on cytogenetic analysis.
Martin, P K; Rowley, J D
1986-07-01
Bone marrow samples from patients with various hematologic disorders were stored at 4 degrees C for up to 5 d before the establishment of a 24-h culture. We tested various factors, including storage time, colony stimulating factor, and methotrexate in an effort to improve metaphase and chromosome quality. Cytogenetic findings for various hematologic diseases were compared in a total of 201 cultures. Cold storage for up to 3 d did not seem to adversely affect the number of mitoses or the quality of chromosome banding when cells were cultured in a system that used both colony stimulating factor and methotrexate. In samples studied in parallel, clonal abnormalities were noted as frequently in cells stored in the cold as in those processed directly.
Frequency and specificity of red blood cell alloimmunization in chilean transfused patients.
Caamaño, José; Musante, Evangelina; Contreras, Margarita; Ulloa, Hernán; Reyes, Carolina; Inaipil, Verónica; Saavedra, Nicolás; Guzmán, Neftalí
2015-01-01
Alloimmunization is an adverse effect of blood transfusions. In Chile, alloimmunization frequency is not established, and for this reason the aim of this study was to investigate the prevalence and specificity of red blood cell (RBC) alloantibodies in Chilean transfused subjects. Records from 4,716 multi-transfused patients were analyzed. In these patients, antibody screening was carried out prior to cross-matching with a commercially available two-cell panel by the microcolum gel test, and samples with a positive screen were analyzed for the specificity of the alloantibody with a 16-cell identification panel. The incidence of RBC alloimmunization in transfused patients was 1.02% (48/4,716) with a higher prevalence in women (40/48). We detected 52 antibodies, the most frequent specificities identified were anti-E (30.8%), anti-K (26.9%), anti-D (7.7%), and anti-Fy(a) (5.8%). The highest incidence of alloantibodies was observed in cancer and gastroenterology patients. The data demonstrated a low alloimmunization frequency in Chilean transfused patients, principally associated with antibodies anti-E, anti-K, anti-D, and anti-Fy(a).
Varlet, Vincent; De Croutte, Emma Lagroy; Augsburger, Marc; Mangin, Patrice
2013-07-01
The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning. © 2013 American Academy of Forensic Sciences.
Donor understandings of blood and the body in relation to more frequent donation.
Lynch, R; Cohn, S
2018-05-01
The INTERVAL trial aimed to find the optimum frequency of blood donation to enhance blood supplies and maintain donor health. This not only requires biological knowledge, but also an appreciation of donor perspectives, and how their experiences and beliefs might be central if any changes are ever to be made. To address this, trial participants were interviewed about their ideas of blood and the body in relation to their experiences of increased donation frequency. Thirty in depth face-to-face interviews conducted with blood donors participating in the trial. Three key themes emerged: ideas about how blood and iron reserves are replenished, and what people did to facilitate this; beliefs about physiological differences relating to age and gender; and practical issues that affected the experience of donation. Overall, participants interviewed welcomed more frequent donation, despite a range of pragmatic concerns. Despite some practical obstacles, increased donation frequency aligned with participant's ideas about bodily replenishment, the value of donation, and their identity as enduring blood donors. They therefore supported the idea of increasing frequency of donation, independently of the biomedical evidence from the trial itself. © 2018 International Society of Blood Transfusion.
NASA Technical Reports Server (NTRS)
Vilchez, Regis A.; Lednicky, John A.; Halvorson, Steven J.; White, Zoe S.; Kozinetz, Claudia A.; Butel, Janet S.
2002-01-01
Systemic non-Hodgkin lymphoma (S-NHL) is a common malignancy during HIV infection, and it is hypothesized that infectious agents may be involved in the etiology. Epstein-Barr virus DNA is found in <40% of patients with AIDS-related S-NHL, suggesting that other oncogenic viruses, such as polyomaviruses, may play a role in pathogenesis. We analyzed AIDS-related S-NHL samples, NHL samples from HIV-negative patients, peripheral blood leukocytes from HIV-infected and -uninfected patients without NHL, and lymph nodes without tumors from HIV-infected patients. Specimens were examined by polymerase chain reaction analysis with use of primers specific for an N-terminal region of the oncoprotein large tumor antigen ( T-ag ) gene conserved among all three polyomaviruses (simian virus 40 [SV40], JC virus, and BK virus). Polyomavirus T-ag DNA sequences, proven to be SV40-specific, were detected more frequently in AIDS-related S-NHL samples (6 of 26) than in peripheral blood leukocytes from HIV-infected patients (6 of 26 vs. 0 of 69; p =.0001), NHL samples from HIV-negative patients (6 of 26 vs. 0 of 10; p =.09), or lymph nodes (6 of 26 vs. 0 of 7; p =.16). Sequences of C-terminal T-ag DNA from SV40 were amplified from two AIDS-related S-NHL samples. Epstein-Barr virus DNA sequences were detected in 38% (10 of 26) AIDS-related S-NHL samples, 50% (5 of 10) HIV-negative S-NHL samples, and 57% (4 of 7) lymph nodes. None of the S-NHL samples were positive for both Epstein-Barr virus DNA and SV40 DNA. Further studies of the possible role of SV40 in the pathogenesis of S-NHL are warranted.
Diabetes - low blood sugar - self-care
... doctor right away. Talk to Your Doctor or Nurse If you use insulin and your blood sugar ... frequently or consistently low, ask your doctor or nurse if you: Are injecting your insulin the right ...
Rattner, B.A.; Golden, N.H.; Toschik, P.C.; McGowan, P.C.; Custer, T.W.
2008-01-01
In 2000, 2001, and 2002, blood and feather samples were collected from 40-45-day-old nestling ospreys (Pandion haliaetus) from Chesapeake Bay and Delaware Bay and River. Concentrations of 18 metals, metalloids, and other elements were determined in these samples by inductively coupled plasma-mass spectroscopy, and Hg concentrations were measured by cold vapor atomic absorption spectroscopy. When compared to concurrent reference areas (South, West, and Rhode Rivers), mean As and Hg concentrations in blood were greater (p < 0.05) in two of three Chesapeake Bay regions of concern (Baltimore Harbor [As: 1.18 vs. 0.548 mug/g dw], Anacostia River [Hg: 0.305 vs. 0.178 mug/g dw], and Elizabeth River [As: 0.876 vs. 0.663 mug/g dw; Hg: 0.260 vs. 0.180 mug/g dw]). Lead was detected more frequently in blood of nestlings from the highly industrialized Elizabeth River compared to the rural reference area. When compared to the concurrent reference area, mean Al, Ba, Hg, Mn, and Pb concentrations in feathers were substantially greater (p < 0.05) in one or more Chesapeake regions of concern (Anacostia River [Al: 206 vs. 62.1 mug/g dw; Ba: 3.31 vs. 0.823 mug/g dw; Mn: 65.4 vs. 22.9 mug/g dw] and Elizabeth River [Al: 165 vs. 63.5 mug/g dw; Hg: 1.24 vs. 0.599 mug/g dw; Pb 1.47 vs. 0.543 mug/g dw]). When compared to the coastal Inland Bays reference area, feathers of nestlings from northern Delaware Bay and River had greater concentrations (p < 0.05) of Ba (1.90 vs. 0.660 mug/g dw), Fe (258 vs. 109 mug/g dw), Mn (18.5 vs. 4.66 mug/g dw), Mo (0.130 vs. 0.040 mug/g dw), Pb (1.96 vs. 0.624 mug/g dw), and V (0.671 vs. 0.325 mug/g dw), presumably due to extensive metal-working and petroleum refinery activities. Concentrations of Hg in nestling feathers from Delaware were frequently greater than in the Chesapeake. The present findings and those of related reproductive studies suggest that concentrations of several heavy metals (e.g., Cd, Hg, Pb) in nestling blood and feathers from Chesapeake and Delaware Bays were below toxicity thresholds and do not seem to be affecting chick survival during the nestling period.
Laskin, Benjamin L; Huang, Guixia; King, Eileen; Geary, Denis F; Licht, Christoph; Metlay, Joshua P; Furth, Susan L; Kimball, Tom; Mitsnefes, Mark
2017-08-01
No controlled trials in children with end-stage kidney disease have assessed the benefits of more frequently administered hemodialysis (HD). We conducted a multicenter, crossover pilot trial to determine if short, more frequent (5 days per week) in-center HD was feasible and associated with improvements in blood pressure compared with three conventional HD treatments per week. Because adult studies have not controlled for the weekly duration of dialysis, we fixed the total treatment time at 12 h a week of dialysis during two 3-month study periods; only frequency varied from 5 to 3 days per week between study periods. Eight children (median age 16.7 years) consented at three children's hospitals. The prespecified primary composite outcome was a sustained 10% decrease in systolic blood pressure and/or a decrease in antihypertensive medications relative to each study period's baseline. Among the six patients completing both study periods, five (83.3%) experienced the primary outcome during HD performed 5 days per week but not 3 days per week; one of the six (16.7%) achieved that outcome during 3-day but not 5-day (p = 0.22) per week HD. During 5-day HD, all patients had significantly more treatments during which their pre-HD systolic (p = 0.01) or diastolic (p = 0.01) blood pressure was 10% lower than baseline. We observed that more frequent HD sessions per week was feasible and associated with improved blood pressure control, but barriers to changing thrice-weekly standard of care include financial reimbursement and the time demands associated with more frequent treatments.
Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas
2015-01-01
Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.
Effect of Frequent or Extended Hemodialysis on Cardiovascular Parameters: A Meta-analysis
Susantitaphong, Paweena; Koulouridis, Ioannis; Balk, Ethan M.; Madias, Nicolaos E.; Jaber, Bertrand L.
2012-01-01
Background Increased left ventricular (LV) mass is a risk factor for cardiovascular mortality in patients with chronic kidney failure. More frequent or extended hemodialysis (HD) has been hypothesized to have a beneficial effect on LV mass. Study Design Meta-analysis. Setting & Population MEDLINE literature search (inception-April 2011), Cochrane Central Register of Controlled Trials and ClinicalTrials.gov using the search terms “short daily HD”, “daily HD”, “quotidian HD”, “frequent HD”, “intensive HD”, “nocturnal HD”, and “home HD”. Selection Criteria for Studies Single-arm cohort studies (with pre- and post-study evaluations) and randomized controlled trials examining the effect of frequent or extended HD on cardiac morphology and function, and blood pressure parameters. Studies of hemofiltration, hemodiafiltration and peritoneal dialysis were excluded. Intervention Frequent (2–8 hours,> thrice weekly) or extended (>4 hours, thrice weekly) HD as compared with conventional (≤ 4 hours, thrice weekly) HD. Outcomes Absolute changes in cardiac morphology and function, including LV mass index (LVMI) (primary), and blood pressure parameters (secondary). Results We identified 38 single-arm studies, 5 crossover trials and 3 randomized controlled trials. By meta-analysis of 23 study arms, frequent or extended HD significantly reduced LVMI from baseline (−31.2 g/m2, 95% CI, −39.8 to −22.5; P<0.001).The 3 randomized trials found a less pronounced net reduction in LVMI (−7.0 g/m2; 95% CI, −10.2 to −3.7; P<0.001). LV ejection fraction improved by 6.7% (95% CI, 1.6 to 11.9; P=0.01). Other cardiac morphological parameters displayed similar improvements. There were also significant decreases in systolic, diastolic, and mean blood pressure, and mean number of anti-hypertensive medications. Limitations Paucity of randomized controlled trials. Conclusions Conversion from conventional to frequent or extended HD is associated with an improvement in cardiac morphology and function, including LVMI and LV ejection fraction, respectively, and in several blood pressure parameters, which collectively might confer long-term cardiovascular benefit. Trials with long-term clinical outcomes are needed. PMID:22370022
Sekizuka, Tsuyoshi; Yamochi, Tadanori; Firouzi, Sanaz; Sato, Tomoo; Umeki, Kazumi; Sasaki, Daisuke; Hasegawa, Hiroo; Kubota, Ryuji; Sobata, Rieko; Matsumoto, Chieko; Kaneko, Noriaki; Momose, Haruka; Araki, Kumiko; Saito, Masumichi; Nosaka, Kisato; Utsunomiya, Atae; Koh, Ki-Ryang; Ogata, Masao; Uchimaru, Kaoru; Iwanaga, Masako; Sagara, Yasuko; Yamano, Yoshihisa; Okayama, Akihiko; Miura, Kiyonori; Satake, Masahiro; Saito, Shigeru; Itabashi, Kazuo; Yamaguchi, Kazunari; Kuroda, Makoto; Watanabe, Toshiki; Okuma, Kazu
2017-01-01
ABSTRACT Western blotting (WB) for human T cell leukemia virus type 1 (HTLV-1) is performed to confirm anti-HTLV-1 antibodies detected at the initial screening of blood donors and in pregnant women. However, the frequent occurrence of indeterminate results is a problem with this test. We therefore assessed the cause of indeterminate WB results by analyzing HTLV-1 provirus genomic sequences. A quantitative PCR assay measuring HTLV-1 provirus in WB-indeterminate samples revealed that the median proviral load was approximately 100-fold lower than that of WB-positive samples (0.01 versus 0.71 copy/100 cells). Phylogenic analysis of the complete HTLV-1 genomes of WB-indeterminate samples did not identify any specific phylogenetic groups. When we analyzed the nucleotide changes in 19 HTLV-1 isolates from WB-indeterminate samples, we identified 135 single nucleotide substitutions, composed of four types, G to A (29%), C to T (19%), T to C (19%), and A to G (16%). In the most frequent G-to-A substitution, 64% occurred at GG dinucleotides, indicating that APOBEC3G is responsible for mutagenesis in WB-indeterminate samples. Moreover, interestingly, five WB-indeterminate isolates had nonsense mutations in Pol and/or Tax, Env, p12, and p30. These findings suggest that WB-indeterminate carriers have low production of viral antigens because of a combination of a low proviral load and mutations in the provirus, which may interfere with host recognition of HTLV-1 antigens. PMID:28701419
Kuramitsu, Madoka; Sekizuka, Tsuyoshi; Yamochi, Tadanori; Firouzi, Sanaz; Sato, Tomoo; Umeki, Kazumi; Sasaki, Daisuke; Hasegawa, Hiroo; Kubota, Ryuji; Sobata, Rieko; Matsumoto, Chieko; Kaneko, Noriaki; Momose, Haruka; Araki, Kumiko; Saito, Masumichi; Nosaka, Kisato; Utsunomiya, Atae; Koh, Ki-Ryang; Ogata, Masao; Uchimaru, Kaoru; Iwanaga, Masako; Sagara, Yasuko; Yamano, Yoshihisa; Okayama, Akihiko; Miura, Kiyonori; Satake, Masahiro; Saito, Shigeru; Itabashi, Kazuo; Yamaguchi, Kazunari; Kuroda, Makoto; Watanabe, Toshiki; Okuma, Kazu; Hamaguchi, Isao
2017-09-01
Western blotting (WB) for human T cell leukemia virus type 1 (HTLV-1) is performed to confirm anti-HTLV-1 antibodies detected at the initial screening of blood donors and in pregnant women. However, the frequent occurrence of indeterminate results is a problem with this test. We therefore assessed the cause of indeterminate WB results by analyzing HTLV-1 provirus genomic sequences. A quantitative PCR assay measuring HTLV-1 provirus in WB-indeterminate samples revealed that the median proviral load was approximately 100-fold lower than that of WB-positive samples (0.01 versus 0.71 copy/100 cells). Phylogenic analysis of the complete HTLV-1 genomes of WB-indeterminate samples did not identify any specific phylogenetic groups. When we analyzed the nucleotide changes in 19 HTLV-1 isolates from WB-indeterminate samples, we identified 135 single nucleotide substitutions, composed of four types, G to A (29%), C to T (19%), T to C (19%), and A to G (16%). In the most frequent G-to-A substitution, 64% occurred at GG dinucleotides, indicating that APOBEC3G is responsible for mutagenesis in WB-indeterminate samples. Moreover, interestingly, five WB-indeterminate isolates had nonsense mutations in Pol and/or Tax, Env, p12, and p30. These findings suggest that WB-indeterminate carriers have low production of viral antigens because of a combination of a low proviral load and mutations in the provirus, which may interfere with host recognition of HTLV-1 antigens. Copyright © 2017 American Society for Microbiology.
2014-01-01
Background EDTA-dependent pseudothrombocytopenia (EDTA-PTCP) is a common laboratory phenomenon with a prevalence ranging from 0.1-2% in hospitalized patients to 15-17% in outpatients evaluated for isolated thrombocytopenia. Despite its harmlessness, EDTA-PTCP frequently leads to time-consuming, costly and even invasive diagnostic investigations. EDTA-PTCP is often overlooked because blood smears are not evaluated visually in routine practice and histograms as well as warning flags of hematology analyzers are not interpreted correctly. Nonetheless, EDTA-PTCP may be diagnosed easily even by general practitioners without any experiences in blood film examinations. This is the first report illustrating the typical patterns of a platelet (PLT) and white blood cell (WBC) histograms of hematology analyzers. Case presentation A 37-year-old female patient of Caucasian origin was referred with suspected acute leukemia and the crew of the emergency unit arranged extensive investigations for work-up. However, examination of EDTA blood sample revealed atypical lymphocytes and an isolated thrombocytopenia together with typical patterns of WBC and PLT histograms: a serrated curve of the platelet histogram and a peculiar peak on the left side of the WBC histogram. EDTA-PTCP was confirmed by a normal platelet count when examining citrated blood. Conclusion Awareness of typical PLT and WBC patterns may alert to the presence of EDTA-PTCP in routine laboratory practice helping to avoid unnecessary investigations and over-treatment. PMID:24808761
Blood-injection-injury phobia in older adults.
Miloyan, Beyon; Eaton, William W
2016-06-01
This study aims to (i) estimate the prevalence of blood-injection-injury phobia (BIIP) diagnosed as present at any time during the life prior to the interview, with or without another Specific Phobia diagnosed as present during the 12 months prior to the interview, (ii) characterize types and frequencies of co-occurring fears, (iii) evaluate the association with chronic medical conditions and lifetime psychiatric comorbidity, and (iv) explore medical service use associations in a nationally representative sample of older adults. A sample of 8,205 older adults, aged 65 years or older, was derived from Wave 1 of the National Epidemiological Survey on Alcohol and Related Conditions (NESARC). The weighted lifetime prevalence of BIIP with and without 12-month Specific Phobia was 0.6% (95% CI: 0.4-0.8) and 4.2% (95% CI: 3.7-4.8), respectively, and these two groups ranked similarly in terms of sociodemographic, health, and psychiatric characteristics. BIIP most frequently co-occurred with other lifetime fears, and was positively associated with hypertension and lifetime history of anxiety and personality disorders after controlling for sociodemographic and psychiatric confounders. Our findings suggest that lifetime BIIP may bear mental and physical health significance in older adults.
Damhorst, Gregory L.; Duarte-Guevara, Carlos; Chen, Weili; Ghonge, Tanmay; Cunningham, Brian T.; Bashir, Rashid
2015-01-01
Viral load measurements are an essential tool for the long-term clinical care of hum an immunodeficiency virus (HIV)-positive individuals. The gold standards in viral load instrumentation, however, are still too limited by their size, cost, and sophisticated operation for these measurements to be ubiquitous in remote settings with poor healthcare infrastructure, including parts of the world that are disproportionately affected by HIV infection. The challenge of developing a point-of-care platform capable of making viral load more accessible has been frequently approached but no solution has yet emerged that meets the practical requirements of low cost, portability, and ease-of-use. In this paper, we perform reverse-transcription loop-mediated isothermal amplification (RT-LAMP) on minimally processed HIV-spiked whole blood samples with a microfluidic and silicon microchip platform, and perform fluorescence measurements with a consumer smartphone. Our integrated assay shows amplification from as few as three viruses in a ~ 60 nL RT-LAMP droplet, corresponding to a whole blood concentration of 670 viruses per µL of whole blood. The technology contains greater power in a digital RT-LAMP approach that could be scaled up for the determination of viral load from a finger prick of blood in the clinical care of HIV-positive individuals. We demonstrate that all aspects of this viral load approach, from a drop of blood to imaging the RT-LAMP reaction, are compatible with lab-on-a-chip components and mobile instrumentation. PMID:26705482
[User's requests (from a practitioner's perspective)].
Ohnishi, T
1997-08-01
As a practitioner, I have to rely on outside clinical laboratories and affiliated hospitals to perform laboratory tests. In this abstract, I describe specific problems I have encountered with third-party laboratories, and propose solutions for these problems to optimize use of laboratory tests. BLOOD TESTS: The most frequent problem in ordering blood tests is the lack of detailed information regarding sampling conditions. I often have to call laboratories to check whether the sample should be serum or plasma, what volume is needed, whether the sample should be cooled, etc. I propose that clinical laboratories should provide practitioners' manuals that describe specific sampling information. Most laboratories do not keep the data from ultrasonographic tests. The lack of these is most problematic when test results are interpreted differently by laboratories and by practitioners. Retaining the data would also help private laboratories improve the quality of the test by enabling them to compare their interpretations with others'. ANNUAL MEDICAL SCREENING: Even if an abnormal finding is detected at medical screening clinics, the final diagnosis is usually not sent back to the screening facilities. This is highly recommended to establish an official system that mediates the feedback to screening centers. MRI: Due to miscommunication between practitioners and radiologists, the test is sometimes performed inappropriately. A thorough consultation should occur before the test to clarify specific goals for each patient. PATHOLOGICAL TESTS: Interpretation of results is often inconsistent among laboratories. Independent clinical laboratories tend to report results without indicating sample problems, while pathology departments at affiliated hospitals tend to emphasize sample problems instead of diagnosis or suggesting ways to improve sample quality. Mutual communication among laboratories would help standardize the quality of pathological tests.
Makino, Yoshinori; Watanabe, Michiko; Makihara, Reiko Ando; Nokihara, Hiroshi; Yamamoto, Noboru; Ohe, Yuichiro; Sugiyama, Erika; Sato, Hitoshi; Hayashi, Yoshikazu
2016-09-01
Limited sampling points for both amrubicin (AMR) and its active metabolite amrubicinol (AMR-OH) were simultaneously optimized using Akaike's information criterion (AIC) calculated by pharmacokinetic modeling. In this pharmacokinetic study, 40 mg/m(2) of AMR was administered as a 5-min infusion on three consecutive days to 21 Japanese lung cancer patients. Blood samples were taken at 0, 0.08, 0.25, 0.5, 1, 2, 4, 8 and 24 h after drug infusion, and AMR and AMR-OH concentrations in plasma were quantitated using a high-performance liquid chromatography. The pharmacokinetic profile of AMR was characterized using a three-compartment model and that of AMR-OH using a one-compartment model following a first-order absorption process. These pharmacokinetic profiles were then integrated into one pharmacokinetic model for simultaneous fitting of AMR and AMR-OH. After fitting to the pharmacokinetic model, 65 combinations of four sampling points from the concentration profiles were evaluated for their AICs. Stepwise regression analysis was applied to select the sampling points for AMR and AMR-OH to predict the area under the concentration-time curves (AUCs) at best. Of the three combinations that yielded favorable AIC values, 0.25, 2, 4 and 8 h yielded the best AUC prediction for both AMR (R(2) = 0.977) and AMR-OH (R(2) = 0.886). The prediction error for AUC was less than 15%. The optimal limited sampling points of AMR and AMR-OH after AMR infusion were found to be 0.25, 2, 4 and 8 h, enabling less frequent blood sampling in further expanded pharmacokinetic studies for both AMR and AMR-OH. © 2016 John Wiley & Sons Australia, Ltd.
[Distribution of DRD4 and DAT1 alleles from dopaminergic system in a mixed Chilean population].
Vieyra, Gonzalo; Moraga, Mauricio; Henríquez, Hugo; Aboitiz, Francisco; Rothhammer, Francisco
2003-02-01
Genes for dopamine receptor DRD4 and dopamine transporter DAT1 are highly polymorphic. Two alleles of these genes, namely the DRD4.7 and the DAT1*9 are frequently associated to the attention deficit disorder with hyperactivity. In Europe, the allele for DRD4 receptor with four repetitions (DRD4.4) has the highest frequency, with a median of 69%, followed by DRD4.7, with a frequency of 15%. South American indigenous populations have higher frequencies for DRD4.7 (61%) than for DRD4.4 (29%). The ten repetition allele for DAT1 transporter has a high frequency among Europeans (72%) and Amerindians (100%). The allele DAT1*9 is the second most frequent allele. To study the frequency of DRD4 and DAT1 alleles in a Chilean population sample. One hundred serum samples were obtained from blood donors in two public hospitals in Santiago. Polymorphic regions for DRD4 and DAT1 were amplified by polymerase chain reaction. The allele DRD4.4 had a frequency of 59% and DRD4.7 a frequency of 27%. The allele DAT1*10 had a frequency of 74%, followed by DAT 1*9, with a frequency of 23%. In a Chilean population sample, the frequency of DRD4 and DAT1 alleles was very similar to that of European populations.
Chase, Peter B; Hawkins, Jeff; Mosier, Jarrod; Jimenez, Ernest; Boesen, Keith; Logan, Barry K; Walter, Frank G
2016-01-01
Synthetic cannabinoid use has increased in many states, and medicinal and/or recreational marijuana use has been legalized in some states. These changes present challenges to law enforcement drug recognition experts (DREs) who determine whether drivers are impaired by synthetic cannabinoids or marijuana, as well as to clinical toxicologists who care for patients with complications from synthetic cannabinoids and marijuana. Our goal was to compare what effects synthetic cannabinoids and marijuana had on performance and behavior, including driving impairment, by reviewing records generated by law enforcement DREs who evaluated motorists arrested for impaired driving. Data were from a retrospective, convenience sample of de-identified arrest reports from impaired drivers suspected of using synthetic cannabinoids (n = 100) or marijuana (n = 33). Inclusion criteria were arrested drivers who admitted to using either synthetic cannabinoids or marijuana, or who possessed either synthetic cannabinoids or marijuana; who also had a DRE evaluation at the scene; and whose blood screens were negative for alcohol and other drugs. Exclusion criteria were impaired drivers arrested with other intoxicants found in their drug or alcohol blood screens. Blood samples were analyzed for 20 popular synthetic cannabinoids by using liquid chromatography-tandem mass spectrometry. Delta-9-tetrahydrocannabinol (THC) and THC-COOH were quantified by gas chromatography-mass spectrometry. Statistical significance was determined by using Fisher's exact test or Student's t-test, where appropriate, to compare the frequency of characteristics of those in the synthetic cannabinoid group versus those in the marijuana group. 16 synthetic cannabinoid and 25 marijuana records met selection criteria; the drivers of these records were arrested for moving violations. Median age for the synthetic cannabinoid group (n = 16, 15 males) was 20 years (IQR 19-23 years). Median age for the marijuana group (n = 25, 21 males) was 20 years (IQR 19-24 years) (p = 0.46). In the synthetic cannabinoid group, 94% (15/16) admitted to using synthetic cannabinoids. In the marijuana group, 96% (24/25) admitted to using marijuana. Blood was available for testing in 96% (24/25) of the marijuana group; 21 of these 24 had quantitative levels of THC (mean + SD = 10.7 + 5 ng/mL) and THC-COOH (mean + SD = 57.8 + 3 ng/mL). Blood was available for testing in 63% (10/16) of the synthetic cannabinoid group, with 80% (8/10) of these positive for synthetic cannabinoids. Those in the synthetic cannabinoid group were more frequently confused (7/16 [44%] vs. 0/25 [0%], p ≤ 0.003) and disoriented (5/16 [31%] vs. 0/25 [0%], p ≤ 0.003), and more frequently had incoherent, slurred speech (10/16 [63%] vs. 3/25 [12%], p = 0.0014) and horizontal gaze nystagmus (8/16 [50%] vs. 3/25 [12%], p = 0.01) than those in the marijuana group. Drivers under the influence of synthetic cannabinoids were more frequently impaired with confusion, disorientation, and incoherent, slurred speech than drivers under the influence of marijuana in this population evaluated by DREs.
Coagulation Management in Jersey Calves: An ex vivo Study.
Gröning, Sabine; Maas, Judith; van Geul, Svenja; Rossaint, Rolf; Steinseifer, Ulrich; Grottke, Oliver
2017-01-01
Jersey calves are frequently used as an experimental animal model for in vivo testing of cardiac assist devices or orthopedic implants. In this ex vivo study, we analyzed the coagulation system of the Jersey calves and the potential of human-based coagulation management to circumvent perioperative bleeding complications during surgery. Experimental Procedure: Blood from 7 Jersey calves was subjected to standard laboratory tests and thromboelastometry analysis. An ex vivo model of dilutional coagulopathy was used to study the effects of fibrinogen or prothrombin complex concentrate supplementation. Fibrinolysis was induced with tissue plasminogen activator to identify potential therapeutic strategies involving tranexamic acid or aprotinin. Furthermore, anticoagulation strategies were evaluated by incubating the blood samples with dabigatran or rivaroxaban. Baseline values for thromboelastometry and standard laboratory parameters, including prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin III, and D-dimers, were established. Fifty percent diluted blood showed a statistically significant impairment of hemostasis. The parameters significantly improved after the administration of fibrinogen or prothrombin complex concentrate. Tranexamic acid and aprotinin ameliorated tissue plasminogen activator-induced fibrinolysis. Both dabigatran and rivaroxaban significantly prolonged the coagulation parameters. In this ex vivo study, coagulation factors, factor concentrate, antifibrinolytic reagents, and anticoagulants regularly used in the clinic positively impacted coagulation parameters in Jersey calf blood. © 2017 S. Karger AG, Basel.
Human Elimination of Organochlorine Pesticides: Blood, Urine, and Sweat Study
Lane, Kevin; Birkholz, Detlef
2016-01-01
Background. Many individuals have been exposed to organochlorinated pesticides (OCPs) through food, water, air, dermal exposure, and/or vertical transmission. Due to enterohepatic reabsorption and affinity to adipose tissue, OCPs are not efficiently eliminated from the human body and may accrue in tissues. Many epidemiological studies demonstrate significant exposure-disease relationships suggesting OCPs can alter metabolic function and potentially lead to illness. There is limited study of interventions to facilitate OCP elimination from the human body. This study explored the efficacy of induced perspiration as a means to eliminate OCPs. Methods. Blood, urine, and sweat (BUS) were collected from 20 individuals. Analysis of 23 OCPs was performed using dual-column gas chromatography with electron-capture detectors. Results. Various OCPs and metabolites, including DDT, DDE, methoxychlor, endrin, and endosulfan sulfate, were excreted into perspiration. Generally, sweat samples showed more frequent OCP detection than serum or urine analysis. Many OCPs were not readily detected in blood testing while still being excreted and identified in sweat. No direct correlation was found among OCP concentrations in the blood, urine, or sweat compartments. Conclusions. Sweat analysis may be useful in detecting some accrued OCPs not found in regular serum testing. Induced perspiration may be a viable clinical tool for eliminating some OCPs. PMID:27800487
Human Elimination of Organochlorine Pesticides: Blood, Urine, and Sweat Study.
Genuis, Stephen J; Lane, Kevin; Birkholz, Detlef
2016-01-01
Background . Many individuals have been exposed to organochlorinated pesticides (OCPs) through food, water, air, dermal exposure, and/or vertical transmission. Due to enterohepatic reabsorption and affinity to adipose tissue, OCPs are not efficiently eliminated from the human body and may accrue in tissues. Many epidemiological studies demonstrate significant exposure-disease relationships suggesting OCPs can alter metabolic function and potentially lead to illness. There is limited study of interventions to facilitate OCP elimination from the human body. This study explored the efficacy of induced perspiration as a means to eliminate OCPs. Methods . Blood, urine, and sweat (BUS) were collected from 20 individuals. Analysis of 23 OCPs was performed using dual-column gas chromatography with electron-capture detectors. Results . Various OCPs and metabolites, including DDT, DDE, methoxychlor, endrin, and endosulfan sulfate, were excreted into perspiration. Generally, sweat samples showed more frequent OCP detection than serum or urine analysis. Many OCPs were not readily detected in blood testing while still being excreted and identified in sweat. No direct correlation was found among OCP concentrations in the blood, urine, or sweat compartments. Conclusions . Sweat analysis may be useful in detecting some accrued OCPs not found in regular serum testing. Induced perspiration may be a viable clinical tool for eliminating some OCPs.
USDA-ARS?s Scientific Manuscript database
Intensive lifestyle management or frequent goal-based monitoring with pharmacological management can be successful strategies for blood pressure control in overweight and obese adults with type 2 diabetes....
Janssen, Nele; Fernandez-Salas, Ildefonso; Díaz González, Esteban Eduardo; Gaytan-Burns, Alejandro; Medina-de la Garza, Carlos E; Sanchez-Casas, Rosa María; Börstler, Jessica; Cadar, Daniel; Schmidt-Chanasit, Jonas; Jöst, Hanna
2015-11-01
The studie describes the blood-feeding behaviour of mosquitoes in Mexico, to understand host-vector relationships and dynamics of disease transmission. From September 2012 to November 2012 and in November 2013, 911 blood-fed Cx. quinquefasciatus mosquitoes were collected with aspirators inside houses in Chetumal and Cancun. Blood meals were analysed by PCR and subsequent Sanger sequencing of the cytochrome b gene. 93.3% of mosquitoes fed on mammals, 6.5% on birds and 0.2% on reptiles. The most frequent vertebrate hosts were humans (65.4%), dogs (23.2%), chicken (5.4%), cattle (2.2%) and cats (1.8%). Cx. quinquefasciatus most frequently fed on humans and dogs in both studied cities, which is in contrast to a previous study that demonstrated lower prevalence of mammalian blood in engorged Cx. quinquefasciatus. © 2015 John Wiley & Sons Ltd.
Maggi, Ricardo G; Mascarelli, Patricia E; Havenga, Lauren N; Naidoo, Vinny; Breitschwerdt, Edward B
2013-04-15
During a two year period, a 27-year-old female veterinarian experienced migraine headaches, seizures, including status epilepticus, and other neurological and neurocognitive abnormalities. Prior to and during her illness, she had been actively involved in hospital-based work treating domestic animals, primarily cats and dogs, in Grenada and Ireland and anatomical research requiring the dissection of wild animals (including lions, giraffe, rabbits, mongoose, and other animals), mostly in South Africa. The woman reported contact with fleas, ticks, lice, biting flies, mosquitoes, spiders and mites and had also been scratched or bitten by dogs, cats, birds, horses, reptiles, rabbits and rodents. Prior diagnostic testing resulted in findings that were inconclusive or within normal reference ranges and no etiological diagnosis had been obtained to explain the patient's symptoms. PCR assays targeting Anaplasma sp. Bartonella sp. and hemotopic Mycoplasma sp. were used to test patient blood samples. PCR positive amplicons were sequenced directly and compared to Gen Bank sequences. In addition, Bartonella alpha Proteobacteria growth medium (BAPGM) enrichment blood culture was used to facilitate bacterial growth and Bartonella spp. serology was performed by indirect fluorescent antibody testing. Anaplasma platys, Bartonella henselae and Candidatus Mycoplasma haematoparvum DNA was amplified and sequenced from the woman's blood, serum or blood culture samples. Her serum was variably seroreactive to several Bartonella sp. antigens. Despite symptomatic improvement, six months of doxycycline most likely failed to eliminate the B. henselae infection, whereas A. platys and Candidatus M. haematoparvum DNA was no longer amplified from post-treatment samples. As is typical of many veterinary professionals, this individual had frequent exposure to arthropod vectors and near daily contact with persistently bacteremic reservoir hosts, including cats, the primary reservoir host for B. henselae, and dogs, the presumed primary reservoir host for A. platys and Candidatus Mycoplasma haematoparvum. Physicians caring for veterinarians should be aware of the occupational zoonotic risks associated with the daily activities of these animal health professionals.
2013-01-01
Background During a two year period, a 27-year-old female veterinarian experienced migraine headaches, seizures, including status epilepticus, and other neurological and neurocognitive abnormalities. Prior to and during her illness, she had been actively involved in hospital-based work treating domestic animals, primarily cats and dogs, in Grenada and Ireland and anatomical research requiring the dissection of wild animals (including lions, giraffe, rabbits, mongoose, and other animals), mostly in South Africa. The woman reported contact with fleas, ticks, lice, biting flies, mosquitoes, spiders and mites and had also been scratched or bitten by dogs, cats, birds, horses, reptiles, rabbits and rodents. Prior diagnostic testing resulted in findings that were inconclusive or within normal reference ranges and no etiological diagnosis had been obtained to explain the patient’s symptoms. Methods PCR assays targeting Anaplasma spp. Bartonella spp. and hemotopic Mycoplasma spp. were used to test patient blood samples. PCR positive amplicons were sequenced directly and compared to GenBank sequences. In addition, Bartonella alpha Proteobacteria growth medium (BAPGM) enrichment blood culture was used to facilitate bacterial growth and Bartonella spp. serology was performed by indirect fluorescent antibody testing. Results Anaplasma platys, Bartonella henselae and Candidatus Mycoplasma haematoparvum DNA was amplified and sequenced from the woman’s blood, serum or blood culture samples. Her serum was variably seroreactive to several Bartonella sp. antigens. Despite symptomatic improvement, six months of doxycycline most likely failed to eliminate the B. henselae infection, whereas A. platys and Candidatus M. haematoparvum DNA was no longer amplified from post-treatment samples. Conclusions As is typical of many veterinary professionals, this individual had frequent exposure to arthropod vectors and near daily contact with persistently bacteremic reservoir hosts, including cats, the primary reservoir host for B. henselae, and dogs, the presumed primary reservoir host for A. platys and Candidatus Mycoplasma haematoparvum. Physicians caring for veterinarians should be aware of the occupational zoonotic risks associated with the daily activities of these animal health professionals. PMID:23587235
Molaei, Goudarz; Armstrong, Philip M; Abadam, Charles F; Akaratovic, Karen I; Kiser, Jay P; Andreadis, Theodore G
2015-01-01
Eastern equine encephalitis virus (EEEV) causes a highly pathogenic mosquito-borne zoonosis that is responsible for sporadic outbreaks of severe illness in humans and equines in the eastern USA. Culiseta (Cs.) melanura is the primary vector of EEEV in most geographic regions but its feeding patterns on specific avian and mammalian hosts are largely unknown in the mid-Atlantic region. The objectives of our study were to: 1) identify avian hosts of Cs. melanura and evaluate their potential role in enzootic amplification of EEEV, 2) assess spatial and temporal patterns of virus activity during a season of intense virus transmission, and 3) investigate the potential role of Cs. melanura in epidemic/epizootic transmission of EEEV to humans and equines. Accordingly, we collected mosquitoes at 55 sites in Suffolk, Virginia in 2013, and identified the source of blood meals in engorged mosquitoes by nucleotide sequencing PCR products of the mitochondrial cytochrome b gene. We also examined field-collected mosquitoes for evidence of infection with EEEV using Vector Test, cell culture, and PCR. Analysis of 188 engorged Cs. melanura sampled from April through October 2013 indicated that 95.2%, 4.3%, and 0.5% obtained blood meals from avian, mammalian, and reptilian hosts, respectively. American Robin was the most frequently identified host for Cs. melanura (42.6% of blood meals) followed by Northern Cardinal (16.0%), European Starling (11.2%), Carolina Wren (4.3%), and Common Grackle (4.3%). EEEV was detected in 106 mosquito pools of Cs. melanura, and the number of virus positive pools peaked in late July with 22 positive pools and a Maximum Likelihood Estimation (MLE) infection rate of 4.46 per 1,000 mosquitoes. Our findings highlight the importance of Cs. melanura as a regional EEEV vector based on frequent feeding on virus-competent bird species. A small proportion of blood meals acquired from mammalian hosts suggests the possibility that this species may occasionally contribute to epidemic/epizootic transmission of EEEV.
Rocco, Michael V.; Lockridge, Robert S.; Beck, Gerald J.; Eggers, Paul W.; Gassman, Jennifer J.; Greene, Tom; Larive, Brett; Chan, Christopher T.; Chertow, Glenn M.; Copland, Michael; Hoy, Christopher D.; Lindsay, Robert M.; Levin, Nathan W.; Ornt, Daniel B.; Pierratos, Andreas; Pipkin, Mary F.; Rajagopalan, Sanjay; Stokes, John B.; Unruh, Mark L.; Star, Robert A.; Kliger, Alan S.
2013-01-01
Prior small studies have shown multiple benefits of frequent nocturnal hemodialysis compared to conventional three times per week treatments. To study this further, we randomized 87 patients to three times per week conventional hemodialysis or to nocturnal hemodialysis six times per week, all with single-use high-flux dialyzers. The 45 patients in the frequent nocturnal arm had a 1.82-fold higher mean weekly stdKt/Vurea, a 1.74-fold higher average number of treatments per week, and a 2.45-fold higher average weekly treatment time than the 42 patients in the conventional arm. We did not find a significant effect of nocturnal hemodialysis for either of the two coprimary outcomes (death or left ventricular mass (measured by MRI) with a hazard ratio of 0.68, or of death or RAND Physical Health Composite with a hazard ratio of 0.91). Possible explanations for the left ventricular mass result include limited sample size and patient characteristics. Secondary outcomes included cognitive performance, self-reported depression, laboratory markers of nutrition, mineral metabolism and anemia, blood pressure and rates of hospitalization, and vascular access interventions. Patients in the nocturnal arm had improved control of hyperphosphatemia and hypertension, but no significant benefit among the other main secondary outcomes. There was a trend for increased vascular access events in the nocturnal arm. Thus, we were unable to demonstrate a definitive benefit of more frequent nocturnal hemodialysis for either coprimary outcome. PMID:21775973
NASA Astrophysics Data System (ADS)
Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Li, Hongxiao; Li, Yingxin; Fu, Zhigang; Guan, Yang; Li, Gang; Lin, Ling
2017-03-01
Discrimination of human and nonhuman blood is crucial for import-export ports and inspection and quarantine departments. Current methods are usually destructive, complicated and time-consuming. We had previously demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize human blood discrimination. In that research, the spectra were measured with the fiber probe under the surface of blood samples. However, open sampling may pollute the blood samples. Virulence factors in blood samples can also endanger inspectors. In this paper, we explored the classification effect with the blood samples measured in the original containers-vacuum blood vessel. Furthermore, we studied the impact of different conditions of blood samples, such as coagulation and hemolysis, on the prediction ability of the discrimination model. The calibration model built with blood samples in different conditions displayed a satisfactory prediction result. This research demonstrated that visible and near-infrared diffuse reflectance spectroscopy method was potential for noncontact discrimination of human blood.
Fiebig, Lukas; Laux, Ralf; Binder, Rudolf; Ebner, Thomas
2016-10-01
1. Liquid chromatography (LC)-high resolution mass spectrometry (HRMS) techniques proved to be well suited for the identification of predicted and unexpected drug metabolites in complex biological matrices. 2. To efficiently discriminate between drug-related and endogenous matrix compounds, however, sophisticated postacquisition data mining tools, such as control comparison techniques are needed. For preclinical absorption, distribution, metabolism and excretion (ADME) studies that usually lack a placebo-dosed control group, the question arises how high-quality control data can be yielded using only a minimum number of control animals. 3. In the present study, the combination of LC-traveling wave ion mobility separation (TWIMS)-HRMS(E) and multivariate data analysis was used to study the polymer patterns of the frequently used formulation constituents polyethylene glycol 400 and polysorbate 80 in rat plasma and urine after oral and intravenous administration, respectively. 4. Complex peak patterns of both constituents were identified underlining the general importance of a vehicle-dosed control group in ADME studies for control comparison. Furthermore, the detailed analysis of administration route, blood sampling time and gender influences on both vehicle peak pattern as well as endogenous matrix background revealed that high-quality control data is obtained when (i) control animals receive an intravenous dose of the vehicle, (ii) the blood sampling time point is the same for analyte and control sample and (iii) analyte and control samples of the same gender are compared.
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo
2008-02-01
Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.
Shin, Mi-Kyung; Han, Woobum; Joo, Hoon; Bevans-Fonti, Shannon; Shiota, Masakazu; Stefanovski, Darko; Polotsky, Vsevolod Y
2017-04-01
Obstructive sleep apnea is associated with type 2 diabetes. We have previously developed a mouse model of intermittent hypoxia (IH) mimicking oxyhemoglobin desaturations in patients with sleep apnea and have shown that IH increases fasting glucose, hepatic glucose output, and plasma catecholamines. We hypothesize that adrenal medulla modulates glucose responses to IH and that such responses can be prevented by adrenal medullectomy. We performed adrenal medullectomy or sham surgery in lean C57BL/6J mice, which were exposed to IH or intermittent air (control) for 4 wk followed by the frequently sampled intravenous glucose tolerance test (FSIVGTT) in unanesthetized unrestrained animals. IH was administered during the 12-h light phase (9 AM to 9 PM) by decreasing inspired oxygen from 21 to 6.5% 60 cycles/h. Insulin sensitivity (S I ), insulin independent glucose disposal [glucose effectiveness (S G )], and the insulin response to glucose (AIR G ) were determined using the minimal model method. In contrast to our previous data obtained in restrained mice, IH did not affect fasting blood glucose and plasma insulin levels in sham-operated mice. IH significantly decreased S G but did not affect S I and AIR G Adrenal medullectomy decreased fasting blood glucose and plasma insulin levels and increased glycogen synthesis in the liver in hypoxic mice but did not have a significant effect on the FSIVGTT metrics. We conclude that, in the absence of restraints, IH has no effect on glucose metabolism in lean mice with exception of decreased S G , whereas adrenal medullectomy decreases fasting glucose and insulin levels in the IH environment. NEW & NOTEWORTHY To our knowledge, this is the first study examining the role of adrenal catecholamines in glucose metabolism during intermittent hypoxia (IH) in unanesthetized unrestrained C57BL/6J mice. We report that IH did not affect fasting glucose and insulin levels nor insulin sensitivity and insulin secretion during, whereas glucose effectiveness was decreased. Adrenal medullectomy decreased fasting blood glucose and insulin levels in mice exposed to IH but had no effect on glucose metabolism, insulin secretion, and insulin sensitivity. Copyright © 2017 the American Physiological Society.
Shin, Mi-Kyung; Han, Woobum; Joo, Hoon; Bevans-Fonti, Shannon; Shiota, Masakazu; Stefanovski, Darko
2017-01-01
Obstructive sleep apnea is associated with type 2 diabetes. We have previously developed a mouse model of intermittent hypoxia (IH) mimicking oxyhemoglobin desaturations in patients with sleep apnea and have shown that IH increases fasting glucose, hepatic glucose output, and plasma catecholamines. We hypothesize that adrenal medulla modulates glucose responses to IH and that such responses can be prevented by adrenal medullectomy. We performed adrenal medullectomy or sham surgery in lean C57BL/6J mice, which were exposed to IH or intermittent air (control) for 4 wk followed by the frequently sampled intravenous glucose tolerance test (FSIVGTT) in unanesthetized unrestrained animals. IH was administered during the 12-h light phase (9 AM to 9 PM) by decreasing inspired oxygen from 21 to 6.5% 60 cycles/h. Insulin sensitivity (SI), insulin independent glucose disposal [glucose effectiveness (SG)], and the insulin response to glucose (AIRG) were determined using the minimal model method. In contrast to our previous data obtained in restrained mice, IH did not affect fasting blood glucose and plasma insulin levels in sham-operated mice. IH significantly decreased SG but did not affect SI and AIRG. Adrenal medullectomy decreased fasting blood glucose and plasma insulin levels and increased glycogen synthesis in the liver in hypoxic mice but did not have a significant effect on the FSIVGTT metrics. We conclude that, in the absence of restraints, IH has no effect on glucose metabolism in lean mice with exception of decreased SG, whereas adrenal medullectomy decreases fasting glucose and insulin levels in the IH environment. NEW & NOTEWORTHY To our knowledge, this is the first study examining the role of adrenal catecholamines in glucose metabolism during intermittent hypoxia (IH) in unanesthetized unrestrained C57BL/6J mice. We report that IH did not affect fasting glucose and insulin levels nor insulin sensitivity and insulin secretion during, whereas glucose effectiveness was decreased. Adrenal medullectomy decreased fasting blood glucose and insulin levels in mice exposed to IH but had no effect on glucose metabolism, insulin secretion, and insulin sensitivity. PMID:28104753
Son, Jung Tae; Lee, Eunjoo
2015-08-01
To determine the effect of the amount of rice carbohydrates consumed during mealtime on the extent of decrease in postprandial blood pressure in older people with postprandial hypotension. The incidence of postprandial hypotension is as high as 74% in older people with hypertension. A within-subjects repeated measures design was used. Thirty-nine older people in nursing homes received a full serving and a half-serving of rice on two separate days, in random order blood pressure and heart rate were measured before each meal and every 15 minutes for a total of 120 minutes after each meal. Data were analysed using repeated measures analysis of variance and the paired t-test with a Bonferroni adjustment using IBM spss version 19.0. The control and intervention conditions yielded significantly different patterns in systolic blood pressure and diastolic blood pressure. Postprandial hypotension was less frequent under the intervention condition; however, decrease in rice intake did not significantly affect heart rate. Reducing the amount of rice intake per meal prevents postprandial blood pressure decreases in the older people. Small and frequent meals with decreased carbohydrate content are recommended to prevent postprandial hypotension and its complications in the older people. Patients, dieticians and caregivers of older patients should be aware of the importance of diet, especially of decreasing the amount of carbohydrate in a meal. Smaller and more frequent meals are recommended for older people to slow gastric emptying. © 2015 John Wiley & Sons Ltd.
Blood Cell Mitochondrial DNA Content and Premature Ovarian Aging
Cacciatore, Chiara; Busnelli, Marta; Rossetti, Raffaella; Bonetti, Silvia; Paffoni, Alessio; Mari, Daniela; Ragni, Guido; Persani, Luca; Arosio, M.; Beck-Peccoz, P.; Biondi, M.; Bione, S.; Bruni, V.; Brigante, C.; Cannavo`, S.; Cavallo, L.; Cisternino, M.; Colombo, I.; Corbetta, S.; Crosignani, P.G.; D'Avanzo, M.G.; Dalpra, L.; Danesino, C.; Di Battista, E.; Di Prospero, F.; Donti, E.; Einaudi, S.; Falorni, A.; Foresta, C.; Fusi, F.; Garofalo, N.; Giotti, I.; Lanzi, R.; Larizza, D.; Locatelli, N.; Loli, P.; Madaschi, S.; Maghnie, M.; Maiore, S.; Mantero, F.; Marozzi, A.; Marzotti, S.; Migone, N.; Nappi, R.; Palli, D.; Patricelli, M.G.; Pisani, C.; Prontera, P.; Petraglia, F.; Radetti, G.; Renieri, A.; Ricca, I.; Ripamonti, A.; Rossetti, R.; Russo, G.; Russo, S.; Tonacchera, M.; Toniolo, D.; Torricelli, F.; Vegetti, W.; Villa, N.; Vineis, P.; Wasniewsk, M.; Zuffardi, O.
2012-01-01
Primary ovarian insufficiency (POI) is a critical fertility defect characterized by an anticipated and silent impairment of the follicular reserve, but its pathogenesis is largely unexplained. The frequent maternal inheritance of POI together with a remarkable dependence of ovarian folliculogenesis upon mitochondrial biogenesis and bioenergetics suggested the possible involvement of a generalized mitochondrial defect. Here, we verified the existence of a significant correlation between blood and ovarian mitochondrial DNA (mtDNA) content in a group of women undergoing ovarian hyperstimulation (OH), and then aimed to verify whether mtDNA content was significantly altered in the blood cells of POI women. We recruited 101 women with an impaired ovarian reserve: 59 women with premature ovarian failure (POF) and 42 poor responders (PR) to OH. A Taqman copy number assay revealed a significant mtDNA depletion (P<0.001) in both POF and PR women in comparison with 43 women of similar age and intact ovarian reserve, or 53 very old women with a previous physiological menopause. No pathogenic variations in the mitochondrial DNA polymerase γ (POLG) gene were detected in 57 POF or PR women with low blood mtDNA content. In conclusion, blood cell mtDNA depletion is a frequent finding among women with premature ovarian aging, suggesting that a still undetermined but generalized mitochondrial defect may frequently predispose to POI which could then be considered a form of anticipated aging in which the ovarian defect may represent the first manifestation. The determination of mtDNA content in blood may become an useful tool for the POI risk prediction. PMID:22879975
Blood cell mitochondrial DNA content and premature ovarian aging.
Bonomi, Marco; Somigliana, Edgardo; Cacciatore, Chiara; Busnelli, Marta; Rossetti, Raffaella; Bonetti, Silvia; Paffoni, Alessio; Mari, Daniela; Ragni, Guido; Persani, Luca
2012-01-01
Primary ovarian insufficiency (POI) is a critical fertility defect characterized by an anticipated and silent impairment of the follicular reserve, but its pathogenesis is largely unexplained. The frequent maternal inheritance of POI together with a remarkable dependence of ovarian folliculogenesis upon mitochondrial biogenesis and bioenergetics suggested the possible involvement of a generalized mitochondrial defect. Here, we verified the existence of a significant correlation between blood and ovarian mitochondrial DNA (mtDNA) content in a group of women undergoing ovarian hyperstimulation (OH), and then aimed to verify whether mtDNA content was significantly altered in the blood cells of POI women. We recruited 101 women with an impaired ovarian reserve: 59 women with premature ovarian failure (POF) and 42 poor responders (PR) to OH. A Taqman copy number assay revealed a significant mtDNA depletion (P<0.001) in both POF and PR women in comparison with 43 women of similar age and intact ovarian reserve, or 53 very old women with a previous physiological menopause. No pathogenic variations in the mitochondrial DNA polymerase γ (POLG) gene were detected in 57 POF or PR women with low blood mtDNA content. In conclusion, blood cell mtDNA depletion is a frequent finding among women with premature ovarian aging, suggesting that a still undetermined but generalized mitochondrial defect may frequently predispose to POI which could then be considered a form of anticipated aging in which the ovarian defect may represent the first manifestation. The determination of mtDNA content in blood may become an useful tool for the POI risk prediction.
Prevalence of asinine herpesvirus type 5 (AsHV-5) infection in clinically normal Lipizzaner horses.
Rushton, James Oliver; Kolodziejek, Jolanta; Nell, Barbara; Nowotny, Norbert
2014-04-01
The aim of this study was to assess the extent of asinine herpesvirus (AsHV) type 5 infection in 'closed' populations of clinically normal Lipizzaner horses. Peripheral blood mononuclear cells plus nasal and conjunctival swabs were obtained on four occasions over an 18 month period from 266 animals as part of a health surveillance programme. Sequence analysis of samples that were positive by nested consensus herpesvirus PCR but negative using quantified equid herpesvirus (EHV) type 2 and 5 PCR, revealed a total of 51 samples from 39 horses positive for AsHV-5. No statistically significant association between animal age, gender or geographical location and infection status was identified. The findings suggest sub-clinical AsHV-5 infection may be encountered more frequently than previously reported. Copyright © 2013 Elsevier Ltd. All rights reserved.
Oshima, Minako; Deitiker, Philip; Jankovic, Joseph; Aoki, K Roger; Atassi, M Zouhair
2016-04-01
We determined the T-cell proliferative responses of the peripheral blood lymphocytes (PBL) from 25 botulinum neurotoxin (BoNT)-treated patients to 31 overlapping synthetic peptides encompassing the C-terminal half (residues 855-1296) of BoNT/A heavy chain. Responses of PBL to HC peptides varied among patients. Samples from 14 patients treated solely with BoNT/A recognized 2-13 (average 6.4) peptides/sample at Z>3.0 level. Six peptide regions representing residues 855-873, 1023-1041, 1051-1069, 1093-1111, 1135-1153 and 1247-1265 were frequently recognized by 36-57% of these PBLs. Influence of treatment parameters on T-cell recognition of the peptides was also investigated. Copyright © 2015 Elsevier GmbH. All rights reserved.
Kantor, Rami; Bettendorf, Daniel; Bosch, Ronald J.; Mann, Marita; Katzenstein, David; Cu-Uvin, Susan; D’Aquila, Richard; Frenkel, Lisa; Fiscus, Susan; Coombs, Robert
2014-01-01
Background Detectable HIV-1 in body compartments can lead to transmission and antiretroviral resistance. Although sex differences in viral shedding have been demonstrated, mechanisms and magnitude are unclear. We compared RNA levels in blood, genital-secretions and saliva; and drug resistance in plasma and genital-secretions of men and women starting/changing antiretroviral therapy (ART) in the AIDS Clinical Trials Group (ACTG) 5077 study. Methods Blood, saliva and genital-secretions (compartment fluids) were collected from HIV-infected adults (≥13 years) at 14 United-States sites, who were initiating or changing ART with plasma viral load (VL) ≥2,000 copies/mL. VL testing was performed on all compartment fluids and HIV resistance genotyping on plasma and genital-secretions. Spearman rank correlations were used to evaluate concordance and Fisher’s and McNemar’s exact tests to compare VL between sexes and among compartments. Results Samples were available for 143 subjects; 36% treated (23 men, 29 women) and 64% ‘untreated’ (40 men, 51 women). RNA detection was significantly more frequent in plasma (100%) than genital-secretions (57%) and saliva (64%) (P<0.001). A higher proportion of men had genital shedding versus women (78% versus 41%), and RNA detection was more frequent in saliva versus genital-secretions in women when adjusted for censoring at the limit of assay detection. Inter-compartment fluid VL concordance was low in both sexes. In 22 (13 men, 9 women) paired plasma-genital-secretion genotypes from treated subjects, most had detectable resistance in both plasma (77%) and genital-secretions (68%). Resistance discordance was observed between compartments in 14% of subjects. Conclusions HIV shedding and drug resistance detection prior to initiation/change of ART in ACTG 5077 subjects differed among tissues and between sexes, making the gold standard blood-plasma compartment assessment not fully representative of HIV at other tissue sites. Mechanisms of potential sex-dependent tissue compartmentalization should be further characterized to aid in optimizing treatment and prevention of HIV transmission. Trial Registration ClinicalTrials.gov NCT00007488 PMID:24699474
Huen, Karen; Calafat, Antonia M.; Bradman, Asa; Yousefi, Paul; Eskenazi, Brenda; Holland, Nina
2016-01-01
Phthalates are frequently used in personal care products and plasticizers and phthalate exposure is ubiquitous in the US population. Exposure to phthalates during critical periods in utero has been associated with a variety of adverse health outcomes but the biological mechanisms linking these exposures with disease are not well characterized. In this study, we examined the relationship of in utero phthalate exposure with repetitive element DNA methylation, an epigenetic marker of genome instability, in children from the longitudinal birth cohort CHAMACOS. Methylation of Alu and long interspersed nucleotide elements (LINE-1) was determined using pyrosequencing of bisulfite-treated DNA isolated from whole blood samples collected from newborns and 9 year old children (n=355). Concentrations of eleven phthalate metabolites were measured in urine collected from pregnant mothers at 13 and 26 weeks gestation. We found a consistent inverse association between prenatal concentrations of monoethyl phthalate, the most frequently detected urinary metabolite, with cord blood methylation of Alu repeats (β(95%CI):−0.14(−0.28,0.00) and −0.16(−0.31,−0.02)) for early and late pregnancy, respectively, and a similar but weaker association with LINE-1 methylation. Additionally, increases in urinary concentrations of di-(2-ethylhexyl) phthalate metabolites during late pregnancy were associated with lower levels of methylation of Alu repeats in 9 year old blood (significant p-values ranged from 0.003 to 0.03). Our findings suggest that prenatal exposure to some phthalates may influence differences in repetitive element methylation, highlighting epigenetics as a plausible biological mechanism through which phthalates may affect health. PMID:27019040
Radiation-Induced Changes in Serum Lipidome of Head and Neck Cancer Patients
Jelonek, Karol; Pietrowska, Monika; Ros, Malgorzata; Zagdanski, Adam; Suchwalko, Agnieszka; Polanska, Joanna; Marczyk, Michal; Rutkowski, Tomasz; Skladowski, Krzysztof; Clench, Malcolm R.; Widlak, Piotr
2014-01-01
Cancer radiotherapy (RT) induces response of the whole patient’s body that could be detected at the blood level. We aimed to identify changes induced in serum lipidome during RT and characterize their association with doses and volumes of irradiated tissue. Sixty-six patients treated with conformal RT because of head and neck cancer were enrolled in the study. Blood samples were collected before, during and about one month after the end of RT. Lipid extracts were analyzed using MALDI-oa-ToF mass spectrometry in positive ionization mode. The major changes were observed when pre-treatment and within-treatment samples were compared. Levels of several identified phosphatidylcholines, including (PC34), (PC36) and (PC38) variants, and lysophosphatidylcholines, including (LPC16) and (LPC18) variants, were first significantly decreased and then increased in post-treatment samples. Intensities of changes were correlated with doses of radiation received by patients. Of note, such correlations were more frequent when low-to-medium doses of radiation delivered during conformal RT to large volumes of normal tissues were analyzed. Additionally, some radiation-induced changes in serum lipidome were associated with toxicity of the treatment. Obtained results indicated the involvement of choline-related signaling and potential biological importance of exposure to clinically low/medium doses of radiation in patient’s body response to radiation. PMID:24747595
[Toxicologic blood emergency screening].
Cohen, Sabine; Manat, Aurélie; Dumont, Benoit; Bévalot, Fabien; Manchon, Monique; Berny, Claudette
2010-01-01
In order to overcome the stop marketing by Biorad company of automated high performance liquid chromatograph with UV detection (Remedi), we developed a gas chromatography-mass spectrometry (GC-MS) to detect and to give an approximation of the overdose of molecules frequently encountered in drug intoxications. Therefore two hundred eighty seventeen blood samples were collected over a period of one year and allowed us to evaluate and compare the performance of these two techniques. As identification, GC-MS does not identify all molecules detected by Remedi in 24.2% of cases; there is a lack of sensitivity for opiates and the systematic absence of certain molecules such as betablockers. However, in 75.8% of cases the GC-MS detects all molecules found by Remedi and other molecules such as meprobamate, paracetamol, benzodiazepines and phenobarbital. The concentrations obtained are interpreted in terms of overdose showed 15.7% of discrepancy and 84.3% of concordance between the two techniques. The GC-MS technique described here is robust, fast and relatively simple to implement; the identification is facilitated by macro commands and the semi quantification remains manual. Despite a sequence of cleaning the column after each sample, carryover of a sample to the next remains possible. This technique can be used for toxicologic screening in acute intoxications. Nevertheless it must be supplemented by a HPLC with UV detection if molecules such as betablockers are suspected.
Kong, Say Li; Liu, Xingliang; Suhaimi, Nur-Afidah Mohamed; Koh, Kenneth Jia Hao; Hu, Min; Lee, Daniel Yoke San; Cima, Igor; Phyo, Wai Min; Lee, Esther Xing Wei; Tai, Joyce A; Foong, Yu Miin; Vo, Jess Honganh; Koh, Poh Koon; Zhang, Tong; Ying, Jackie Y; Lim, Bing; Tan, Min-Han; Hillmer, Axel M
2017-09-15
Studies on circulating tumor cells (CTCs) have largely focused on platform development and CTC enumeration rather than on the genomic characterization of CTCs. To address this, we performed targeted sequencing of CTCs of colorectal cancer patients and compared the mutations with the matched primary tumors. We collected preoperative blood and matched primary tumor samples from 48 colorectal cancer patients. CTCs were isolated using a label-free microfiltration device on a silicon microsieve. Upon whole genome amplification, we performed amplicon-based targeted sequencing on a panel of 39 druggable and frequently mutated genes on both CTCs and fresh-frozen tumor samples. We developed an analysis pipeline to minimize false-positive detection of somatic mutations in amplified DNA. In 60% of the CTC-enriched blood samples, we detected primary tumor matching mutations. We found a significant positive correlation between the allele frequencies of somatic mutations detected in CTCs and abnormal CEA serum level. Strikingly, we found driver mutations and amplifications in cancer and druggable genes such as APC, KRAS, TP53, ERBB3 , FBXW7 and ERBB2 . In addition, we found that CTCs carried mutation signatures that resembled the signatures of their primary tumors. Cumulatively, our study defined genetic signatures and somatic mutation frequency of colorectal CTCs. The identification of druggable mutations in CTCs of preoperative colorectal cancer patients could lead to more timely and focused therapeutic interventions.
Kong, Say Li; Liu, Xingliang; Suhaimi, Nur-Afidah Mohamed; Koh, Kenneth Jia Hao; Hu, Min; Lee, Daniel Yoke San; Cima, Igor; Phyo, Wai Min; Lee, Esther Xing Wei; Tai, Joyce A.; Foong, Yu Miin; Vo, Jess Honganh; Koh, Poh Koon; Zhang, Tong; Ying, Jackie Y.; Lim, Bing; Tan, Min-Han; Hillmer, Axel M.
2017-01-01
Studies on circulating tumor cells (CTCs) have largely focused on platform development and CTC enumeration rather than on the genomic characterization of CTCs. To address this, we performed targeted sequencing of CTCs of colorectal cancer patients and compared the mutations with the matched primary tumors. We collected preoperative blood and matched primary tumor samples from 48 colorectal cancer patients. CTCs were isolated using a label-free microfiltration device on a silicon microsieve. Upon whole genome amplification, we performed amplicon-based targeted sequencing on a panel of 39 druggable and frequently mutated genes on both CTCs and fresh-frozen tumor samples. We developed an analysis pipeline to minimize false-positive detection of somatic mutations in amplified DNA. In 60% of the CTC-enriched blood samples, we detected primary tumor matching mutations. We found a significant positive correlation between the allele frequencies of somatic mutations detected in CTCs and abnormal CEA serum level. Strikingly, we found driver mutations and amplifications in cancer and druggable genes such as APC, KRAS, TP53, ERBB3, FBXW7 and ERBB2. In addition, we found that CTCs carried mutation signatures that resembled the signatures of their primary tumors. Cumulatively, our study defined genetic signatures and somatic mutation frequency of colorectal CTCs. The identification of druggable mutations in CTCs of preoperative colorectal cancer patients could lead to more timely and focused therapeutic interventions. PMID:28978093
Beta-hydroxybutyrate in milk as screening test for subclinical ketosis in dairy cows.
Ježek, J; Cincović, M R; Nemec, M; Belić, B; Djoković, R; Klinkon, M; Starič, J
2017-09-26
Ketosis is a very frequent metabolic disease in dairy cows, resulting in lower milk production, impaired fertility and increased frequency of other diseases. The course of the disease is often subclinical, so early detection is very important. The aim of the study was to investigate the relation between the concentration of beta-hydroxybutyrate in blood and milk and to determine the cut-off value in milk for detection of subclinical ketosis. The study included 94 cows, which were in the first third of lactation. Beta-hydroxybutyrate (BHB) concentrations were measured in blood and milk serum using a biochemical analyser. The average concentration of BHB in the blood serum samples was 1.14 mmol/L while in the milk it was about ten times lower at 0.117 mmol/L. A statistically significant positive correlation between the concentration of BHB in blood and milk (r=0.705, p<0.001) was found. In cows with BHB in blood below 2.0 mmol/L a stronger correlation between blood and milk BHB was established (r=0.658, p<0.001) than in cows with blood BHB above 2.0 mmol/L (r=-0.292, p=0.206). Therefore, BHB in milk is a very suitable indicator in the diagnosis of subclinical ketosis as there is a good correlation between BHB in the blood and milk of cows with subclinical ketosis. The cut-off concentration of BHB in milk set at ≥0.080 mmol/L (AUC=0.91±0.03; p<0.001) is a significant indicator for subclinical ketosis in dairy cows. The sensitivity of the test was 94% and specificity 74%. Beta-hydroxybutyrate in milk is a good indicator of subclinical ketosis in dairy cows and can be measured accurately with a biochemical analyser.
Stauffer, William M.; Cartwright, Charles P.; Olson, Douglas; Juni, Billie Anne; Taylor, Charlotte M; Bowers, Susan H.; Hanson, Kevan L.; Rosenblatt, Jon E.; Boulware, David R.
2010-01-01
Background Approximately 4 million U.S. travelers to developing countries are ill enough to seek healthcare with 1,500 malaria cases reported in the U.S. annually. The diagnosis of malaria is frequently delayed due to the time to prepare malaria blood films and lack of technical expertise. An easy, reliable rapid diagnostic test (RDT) with high sensitivity and negative predictive value (NPV), particularly for Plasmodium falciparum, would be clinically useful. The study objective was to determine the diagnostic performance of the FDA-approved NOW® Malaria Test in comparison to traditional thick and thin blood smears for malaria diagnosis. Methods This prospective study tested 852 consecutive blood samples sent for thick and thin smears with blinded, malaria rapid tests at three hospital laboratories during 2003–2006. Polymerase chain reaction (PCR) verified positive tests and discordant results. Results Malaria occurred in 11% (95/852). The rapid test had superior performance than the standard Giemsa thick blood smear (P=.003). The rapid test’s sensitivity for all malaria was 97% (92/95) vs. 85% (81/95) by blood smear, and the RDT had superior NPV of 99.6% vs. 98.2% (P=.001). The P. falciparum performance was excellent with 100% rapid test sensitivity versus only 88% (65/74) by blood smear (P=.003). Conclusions This operational study demonstrates the FDA-approved rapid malaria test is superior to a single set of blood smears performed under routine U.S. clinical laboratory conditions. The most valuable clinical role of the RDT is in the rapid diagnosis or the exclusion of P. falciparum malaria, which is particularly useful in outpatient settings when evaluating febrile travelers. PMID:19686072
Frequent hemodialysis with NxStage system in pediatric patients receiving maintenance hemodialysis.
Goldstein, Stuart L; Silverstein, Douglas M; Leung, Jocelyn C; Feig, Daniel I; Soletsky, Beth; Knight, Cathy; Warady, Bradley A
2008-01-01
Recent evidence from adult hemodialysis (HD) patient studies reveal improved biochemical control and reported health-related quality of life after transition from conventional thrice weekly to daily home maintenance HD treatment. Published pediatric frequent dialysis experiences demonstrate similar improvement but all used conventional HD machines, which employ a treated municipal water supply, thereby frequently exposing patients to proinflammatory components. We report our pediatric experience with six-times-weekly HD using the NxStage system, which uses sterile dialysis fluid to provide dialysis in the home or center setting. Four patients (weight range 38-61.4 kg) completed the 16-week study. Patients exhibited progressive reductions in casual pretreatment systolic and diastolic blood pressures, discontinuation of antihypertensive medications, and decreased blood pressure load by ambulatory blood pressure monitoring. Mean serum phosphorus improved without change in phosphorus binder medication, and all three patients with a normalized protein catabolic rate <1 g/kg per day at the beginning of the study improved to a normalized protein catabolic rate (nPCR) of >1.1 g/kg per day. Patients reported no adverse effects. Variable changes in proinflammatory cytokine levels were observed. We suggest that frequent HD with the NxStage system be considered for children who would benefit from home-based maintenance dialysis.
Page-Sharp, Madhu; Coward, Jonathan; Moore, Brioni R; Salman, Sam; Marshall, Lewis; Davis, Timothy M E; Batty, Kevin T; Manning, Laurens
2017-08-01
Rheumatic heart disease (RHD) remains an important global health challenge. Administration of benzathine penicillin (BPG) every 3 to 4 weeks is recommended as a secondary prophylaxis to prevent recurrent episodes of acute rheumatic fever and subsequent RHD. Following intramuscular injection, BPG is hydrolyzed to penicillin G (benzylpenicillin). However, little is known of the pharmacokinetics (PK) of BPG in pediatric populations at high risk of RHD or of the pharmacokinetic-pharmacodynamic relationship between penicillin exposure and clinically relevant outcomes. Dried blood spot (DBS) assays can facilitate PK studies in situations where frequent venous blood sampling is logistically difficult. A liquid chromatography-mass spectroscopy assay for penicillin G in plasma and DBS was developed and validated. Application of the DBS assay for PK studies was confirmed using samples from adult patients receiving penicillin as part of an infection management plan. The limit of quantification for penicillin G in DBS was 0.005 mg/liter. Penicillin G is stable in DBS for approximately 12 h at room temperature (22°C), 6 days at 4°C, and >1 month at -20°C. Plasma and DBS penicillin G concentrations for patients receiving BPG and penicillin G given via bolus doses correlated well and had comparable time-concentration profiles. There was poor correlation for patients receiving penicillin via continuous infusions, perhaps as a result of the presence of residual penicillin in the peripherally inserted central catheter, from which the plasma samples were collected. The present DBS penicillin G assay can be used as a surrogate for plasma concentrations to provide valid PK data for studies of BPG and other penicillin preparations developed to prevent rheumatic fever and RHD. Copyright © 2017 American Society for Microbiology.
Page-Sharp, Madhu; Coward, Jonathan; Moore, Brioni R.; Marshall, Lewis; Batty, Kevin T.
2017-01-01
ABSTRACT Rheumatic heart disease (RHD) remains an important global health challenge. Administration of benzathine penicillin (BPG) every 3 to 4 weeks is recommended as a secondary prophylaxis to prevent recurrent episodes of acute rheumatic fever and subsequent RHD. Following intramuscular injection, BPG is hydrolyzed to penicillin G (benzylpenicillin). However, little is known of the pharmacokinetics (PK) of BPG in pediatric populations at high risk of RHD or of the pharmacokinetic-pharmacodynamic relationship between penicillin exposure and clinically relevant outcomes. Dried blood spot (DBS) assays can facilitate PK studies in situations where frequent venous blood sampling is logistically difficult. A liquid chromatography-mass spectroscopy assay for penicillin G in plasma and DBS was developed and validated. Application of the DBS assay for PK studies was confirmed using samples from adult patients receiving penicillin as part of an infection management plan. The limit of quantification for penicillin G in DBS was 0.005 mg/liter. Penicillin G is stable in DBS for approximately 12 h at room temperature (22°C), 6 days at 4°C, and >1 month at −20°C. Plasma and DBS penicillin G concentrations for patients receiving BPG and penicillin G given via bolus doses correlated well and had comparable time-concentration profiles. There was poor correlation for patients receiving penicillin via continuous infusions, perhaps as a result of the presence of residual penicillin in the peripherally inserted central catheter, from which the plasma samples were collected. The present DBS penicillin G assay can be used as a surrogate for plasma concentrations to provide valid PK data for studies of BPG and other penicillin preparations developed to prevent rheumatic fever and RHD. PMID:28559267
Sustainable HIV treatment in Africa through viral-load-informed differentiated care.
Phillips, Andrew; Shroufi, Amir; Vojnov, Lara; Cohn, Jennifer; Roberts, Teri; Ellman, Tom; Bonner, Kimberly; Rousseau, Christine; Garnett, Geoff; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Bansi-Matharu, Loveleen; Miners, Alec; Lundgren, Jens D; Eaton, Jeffrey W; Parkes-Ratanshi, Rosalind; Katz, Zachary; Maman, David; Ford, Nathan; Vitoria, Marco; Doherty, Meg; Dowdy, David; Nichols, Brooke; Murtagh, Maurine; Wareham, Meghan; Palamountain, Kara M; Chakanyuka Musanhu, Christine; Stevens, Wendy; Katzenstein, David; Ciaranello, Andrea; Barnabas, Ruanne; Braithwaite, R Scott; Bendavid, Eran; Nathoo, Kusum J; van de Vijver, David; Wilson, David P; Holmes, Charles; Bershteyn, Anna; Walker, Simon; Raizes, Elliot; Jani, Ilesh; Nelson, Lisa J; Peeling, Rosanna; Terris-Prestholt, Fern; Murungu, Joseph; Mutasa-Apollo, Tsitsi; Hallett, Timothy B; Revill, Paul
2015-12-03
There are inefficiencies in current approaches to monitoring patients on antiretroviral therapy in sub-Saharan Africa. Patients typically attend clinics every 1 to 3 months for clinical assessment. The clinic costs are comparable with the costs of the drugs themselves and CD4 counts are measured every 6 months, but patients are rarely switched to second-line therapies. To ensure sustainability of treatment programmes, a transition to more cost-effective delivery of antiretroviral therapy is needed. In contrast to the CD4 count, measurement of the level of HIV RNA in plasma (the viral load) provides a direct measure of the current treatment effect. Viral-load-informed differentiated care is a means of tailoring care so that those with suppressed viral load visit the clinic less frequently and attention is focussed on those with unsuppressed viral load to promote adherence and timely switching to a second-line regimen. The most feasible approach to measuring viral load in many countries is to collect dried blood spot samples for testing in regional laboratories; however, there have been concerns over the sensitivity and specificity of this approach to define treatment failure and the delay in returning results to the clinic. We use modelling to synthesize evidence and evaluate the cost-effectiveness of viral-load-informed differentiated care, accounting for limitations of dried blood sample testing. We find that viral-load-informed differentiated care using dried blood sample testing is cost-effective and is a recommended strategy for patient monitoring, although further empirical evidence as the approach is rolled out would be of value. We also explore the potential benefits of point-of-care viral load tests that may become available in the future.
Hemberg, E; Einarsson, S; Kútvölgyi, G; Lundeheim, N; Bagge, E; Båverud, V; Jones, B; Morrell, J M
2015-07-01
This study investigated the relationship of the health of the newborn foal and (1) number of polymorphonuclear leukocytes (PMNLs) in the amniotic fluid, (2) bacteria present in the amniotic fluid and the venous umbilical blood, and (3) bacteria present in the uterus of the newly foaled mare. A further aim was to investigate relationships between the bacteriologic findings in the amniotic fluid, umbilical blood, and uterus postpartum. Samples were taken from 50 Standardbred trotter foaling mares from a well-managed stud in Sweden. Parturition was spontaneous in all cases. Length of pregnancy, parturition and postpartum complications, health status of the foal, the time between foaling and the expulsion of the placenta, and the number of postfoaling mares becoming pregnant after insemination were recorded. Amniotic fluid was collected when the amniotic vesicle was clearly visible; it was analyzed for bacteriology and occurrence of PMNLs. Umbilical blood was analyzed for the presence of bacteria and the concentration of serum amyloid A. The uterus of the mare was swabbed for bacteriology 6 to 17 hours postpartum. A blood sample was taken from the foal before administering plasma. The foals were divided into two groups: group 1 required up to 2 hours to rise after birth (≤2 hours; 31 foals) and group 2 required more than two hours (>2 hours; 19 foals). The length of gestation varied between 332 and 356 days; there was no significant difference in gestation length between the two foal groups. Partus and postpartum complications occurred in a significantly higher proportion of mares giving birth to group 2 foals than group 1 foals (P = 0.02), although uterine culture postpartum and the subsequent pregnancy rate per season were not different between the groups. Compromised health status was significantly higher among foals belonging to group 2 than group 1 (P = 0.001). Most of the amniotic samples contained 5% or less PMNLs. Only three samples contained more than 30% PMNLs; group 2 foals had the highest percentage of PMNLs. Bacterial growth was found in both amniotic fluid (57%) and umbilical blood (35%) in mares irrespective of whether their foals were healthy or compromised. Coagulase-negative staphylococci were the most frequent bacteria. There were no differences in bacterial occurrence in amniotic fluid or in umbilical blood between the two foal groups. Copyright © 2015 Elsevier Inc. All rights reserved.
Albrich, Werner C.; van der Linden, Mark P. G.; Bénet, Thomas; Chou, Monidarin; Sylla, Mariam; Barreto Costa, Patricia; Richard, Nathalie; Klugman, Keith P.; Endtz, Hubert P.; Paranhos-Baccalà, Gláucia; Telles, Jean-Noël
2016-01-01
For epidemiological and surveillance purposes, it is relevant to monitor the distribution and dynamics of Streptococcus pneumoniae serotypes. Conventional serotyping methods do not provide rapid or quantitative information on serotype loads. Quantitative serotyping may enable prediction of the invasiveness of a specific serotype compared to other serotypes carried. Here, we describe a novel, rapid multiplex real-time PCR assay for identification and quantification of the 40 most prevalent pneumococcal serotypes and the assay impacts in pneumonia specimens from emerging and developing countries. Eleven multiplex PCR to detect 40 serotypes or serogroups were optimized. Quantification was enabled by reference to standard dilutions of known bacterial load. Performance of the assay was evaluated to specifically type and quantify S. pneumoniae in nasopharyngeal and blood samples from adult and pediatric patients hospitalized with pneumonia (n = 664) from five different countries. Serogroup 6 was widely represented in nasopharyngeal specimens from all five cohorts. The most frequent serotypes in the French, South African, and Brazilian cohorts were 1 and 7A/F, 3 and 19F, and 14, respectively. When both samples were available, the serotype in blood was always present as carriage with other serotypes in the nasopharynx. Moreover, the ability of a serotype to invade the bloodstream may be linked to its nasopharyngeal load. The mean nasopharyngeal concentration of the serotypes that moved to the blood was 3 log-fold higher than the ones only found in the nasopharynx. This novel, rapid, quantitative assay may potentially predict some of the S. pneumoniae serotypes invasiveness and assessment of pneumococcal serotype distribution. PMID:26986831
Cinel, G; Pekcan, S; Ozçelik, U; Alp, A; Yalçın, E; Doğru Ersöz, D; Kiper, N
2014-08-01
Cytomegalovirus (CMV) pneumonitis in immunocompetent hosts is uncommon but is being recognized more frequently, particularly when presenting as severe viral pneumonia. The objective of this study was to examine lower respiratory tract CMV infection in immunocompetent wheezy infants, based on polymerase chain reaction (PCR) in bronchoalveolar lavage (BAL) fluid, to compare CMV PCR results in BAL and in blood samples and to evaluate the benefits of antiviral ganciclovir therapy in these patients. Retrospective review of the records of patients referred to our tertiary care hospital between January 2000 and July 2010 who had unexplained persistent wheezing and underwent fibreoptic flexible bronchoscopy (FFB). Fibreoptic flexible bronchoscopy was applied to 102 infants with persistent wheezing and diffuse interstitial infiltration on radiological investigations; so CMV PCR in BAL fluid was performed. CMV PCR in BAL fluid was positive in 51 patients. Retrospectively, we had access to the files of 25 of these patients. The mean CMV PCR in BAL fluid was 334 840 copies/mL. Only eight patients had CMV PCR positivity in their blood samples (mean: 2026·3 copies/mL). There was not a relationship between BAL and blood CMV PCR values based on Spearman's correlation analysis (r = -0·008). Fourteen patients had severe respiratory symptoms and received ganciclovir therapy. Twelve of them fully recovered. Bronchoalveolar lavage fluid CMV PCR was superior to blood CMV PCR in diagnosing lower respiratory tract infections caused by CMV in immunocompetent infants. Ganciclovir therapy may be effective in selected immunocompetent wheezy infants with CMV PCR positivity in BAL fluid. © 2014 John Wiley & Sons Ltd.
Jadranin, Zeljko; Suljagić, Vesna; Todorović, Veljko; Trkuljić, Miroljub; Vucetić, Dusan
2012-01-01
Military personnel is a population group at special risk of exposure to sexually transmitted diseases (STD). In peacetime, STD infection rates among service members are generally 2 to 5 times higher than among civilian population. In time of conflict, the differences can be 50 or more times greater. This study describes sexual behavior as a risk factor for STD in the Armed Forces of Serbia. The sample of 5 617 voluntary blood donors from the Armed Forces of Serbia gave blood and filled World Health Organization Questionnaire about sexual behavior within January 2007 - December 2008 period. The mandatory testing of voluntary blood donors was performed in the Institute of Transfusiology Military Medical Academy in Belgrade, by the specific immunoenzyme tests and polymerasa chain reaction tests for HIV, hepatitis B, C and syphilis. Statistical analysis of data was done using State for Windows 93, USA, 1996. We identified 36 soldiers with some form of STDs. This study showed that 1 668 (29.7%) tested soldiers reported always using condoms, 1 725 (30.72%) almost always, 1 238 (20.04%) sometimes, 495 (8.81%) almost never and 490 (8.73%) never. Among the sample, 449 (7.99%) soldiers reported sexual contacts with partners with high risk of sexual behavior, whilst 22 (0.37%) of them reported homosexual and bisexual contacts. This study reported STDs found in voluntary blood donors among the service members of the Armed Forces of Serbia, but none of them was identified to be HIV positive. Soldiers with the most frequent risk behavior were reported to be those with inconsistent condom use. In the future, the STD Control and Prevention Program should be more intensively conducted among the members of the Armed Forces of Serbia.
Henthorn, Thomas K; Avram, Michael J; Dahan, Albert; Gustafsson, Lars L; Persson, Jan; Krejcie, Tom C; Olofsen, Erik
2018-05-16
The pharmacokinetics of infused drugs have been modeled without regard for recirculatory or mixing kinetics. We used a unique ketamine dataset with simultaneous arterial and venous blood sampling, during and after separate S(+) and R(-) ketamine infusions, to develop a simplified recirculatory model of arterial and venous plasma drug concentrations. S(+) or R(-) ketamine was infused over 30 min on two occasions to 10 healthy male volunteers. Frequent, simultaneous arterial and forearm venous blood samples were obtained for up to 11 h. A multicompartmental pharmacokinetic model with front-end arterial mixing and venous blood components was developed using nonlinear mixed effects analyses. A three-compartment base pharmacokinetic model with additional arterial mixing and arm venous compartments and with shared S(+)/R(-) distribution kinetics proved superior to standard compartmental modeling approaches. Total pharmacokinetic flow was estimated to be 7.59 ± 0.36 l/min (mean ± standard error of the estimate), and S(+) and R(-) elimination clearances were 1.23 ± 0.04 and 1.06 ± 0.03 l/min, respectively. The arm-tissue link rate constant was 0.18 ± 0.01 min and the fraction of arm blood flow estimated to exchange with arm tissue was 0.04 ± 0.01. Arterial drug concentrations measured during drug infusion have two kinetically distinct components: partially or lung-mixed drug and fully mixed-recirculated drug. Front-end kinetics suggest the partially mixed concentration is proportional to the ratio of infusion rate and total pharmacokinetic flow. This simplified modeling approach could lead to more generalizable models for target-controlled infusions and improved methods for analyzing pharmacokinetic-pharmacodynamic data.
Lead exposure in Mexican radiator repair workers.
Dykeman, Ronald; Aguilar-Madrid, Guadalupe; Smith, Tom; Juárez-Pérez, Cuauhtemoc Arturo; Piacitelli, Gregory M; Hu, Howard; Hernandez-Avila, Mauricio
2002-03-01
Lead exposure was investigated among 73 Mexican radiator repair workers (RRWs), 12 members of their family (4 children and 8 wives), and 36 working controls. RRWs were employed at 4 radiator repair shops in Mexico City and 27 shops in Cuernavaca and surrounding areas. Exposure was assessed directly through the use of personal air sampling and hand wipe samples. In addition, industrial hygiene inspections were performed and detailed questionnaires were administered. Blood lead levels were measured by graphite furnace atomic absorption spectroscopy (AAS). The mean (SD) values for blood lead of the RRWs, 35.5 (13.5) microg/dl, was significantly greater than the same values for the working controls, 13.6 (8.7) microg/dl; P < 001. After excluding a single outlier (247 microg/m(3)), air lead levels ranged from 0 to 99 microg/m(3) with a mean (SD) value of 19 (23) microg/m(3) (median = 7.9 microg/m(3)). In a final multivariate regression model of elevated blood lead levels, the strongest predictors were smoking (vs. non-smoking), the number of radiators repaired per day on average, and the use (vs. non-use) of a uniform while at work, which were associated with blood lead elevations of 11.4 microg/dl, 1.95 microg/dl/radiator/day, and 16.4 microg/dl, respectively (all P <.05). Uniform use was probably a risk factor because they were not laundered regularly and consequently served as reservoir of contamination on which RRWs frequently wiped their hands. Lead exposure is a significant problem of radiator repair work, a small industry that is abundant in Mexico and other developing countries. Copyright 2002 Wiley-Liss, Inc.
Cardiovascular Autonomic Dysfunction in Patients with Drug-Induced Parkinsonism
Ryu, Dong-Woo; Oh, Ju-Hee; Lee, Yang-Hyun; Park, Sung-Jin; Jeon, Kipyung; Lee, Jong-Yun; Ho, Seong Hee; So, Jungmin; Im, Jin Hee; Lee, Kwang-Soo
2017-01-01
Background and Purpose Recent studies have shown that several nonmotor symptoms differ between Parkinson's disease (PD) and drug-induced parkinsonism (DIP). However, there have been no reports on cardiovascular autonomic function in DIP, and so this study investigated whether cardiovascular autonomic function differs between PD and DIP patients. Methods This study consecutively enrolled 20 DIP patients, 99 drug-naïve PD patients, and 25 age-matched healthy controls who underwent head-up tilt-table testing and 24-h ambulatory blood pressure monitoring. Results Orthostatic hypotension was more frequent in patients with PD or DIP than in healthy controls. In DIP, orthostatic hypotension was associated with the underlying psychiatric diseases and neuroleptics use, whereas prokinetics were not related to orthostatic hypotension. The supine blood pressure, nighttime blood pressure, and nocturnal blood pressure dipping did not differ significantly between the DIP and control groups. Supine hypertension and nocturnal hypertension were more frequent in PD patients than in controls. Conclusions The included DIP patients frequently exhibited orthostatic hypotension that was associated with the underlying diseases as well as the nature of and exposure time to the offending drugs. Clinicians should individualize the manifestations of DIP according to underlying diseases as well as the action mechanism of and exposure time to each offending drug. PMID:27730767
Kipper, Karin; Barker, Charlotte I S; Standing, Joseph F; Sharland, Mike; Johnston, Atholl
2018-01-01
Penicillins are widely used to treat infections in children; however, the evidence is continuing to evolve in defining the optimal dosing. Modern pediatric pharmacokinetic study protocols frequently favor opportunistic, "scavenged" sampling. This study aimed to develop a small-volume single assay for five major penicillins and to assess the influence of sample degradation on inferences made using pharmacokinetic modeling, to investigate the suitability of scavenged sampling strategies. Using a rapid ultrahigh-performance liquid chromatographic-tandem mass spectrometric method, an assay for five penicillins (amoxicillin, ampicillin, benzylpenicillin, piperacillin, and flucloxacillin) in blood plasma was developed and validated. Penicillin stabilities were evaluated under different conditions. Using these data, the impact of drug degradation on inferences made during pharmacokinetic modeling was evaluated. All evaluated penicillins indicated good stability at room temperature (23 ± 2°C) over 1 h, remaining in the range of 98 to 103% of the original concentration. More-rapid analyte degradation had already occurred after 4 h, with stability ranging from 68% to 99%. Stability over longer periods declined: degradation of up to 60% was observed with delayed sample processing of up to 24 h. Modeling showed that analyte degradation can lead to a 30% and 28% bias in clearance and volume of distribution, respectively, and falsely show nonlinearity in clearance. Five common penicillins can now be measured in a single low-volume blood sample. Beta-lactam chemical instability in plasma can cause misleading pharmacokinetic modeling results, which could impact upon model-based dosing recommendations and the forthcoming era of beta-lactam therapeutic drug monitoring. Copyright © 2017 American Society for Microbiology.
Sorrentino, G; Fumagalli, M; Milani, S; Cortinovis, I; Zorz, A; Cavallaro, G; Mosca, F; Plevani, L
2017-07-01
The heel stick is the method of choice in most neonatal units for capillary blood sampling, and it represents the most common event among all painful procedures performed on newborns. The type and design of heel stick device and the clinical procedure to collect a blood sample may have an impact on newborn pain response as well. To compare the pain response and efficiency of different automated devices for capillary blood collection in newborns. Randomized clinical trial. Postnatal ward of a tertiary-care university hospital in Italy. Newborn infants at gestational age ≥34 weeks undergoing the metabolic screening test after the 49th hour of life. A total of 762 neonates were recruited and randomized into 6 groups (127 babies in each group) assigned to 6 different capillary blood collection devices (Ames Minilet™ Lancet; Cardinal Health Gentleheel ® ; Natus Medical NeatNick™; BD Quikheel™ Lancet; Vitrex Steriheel ® Baby Lancet; Accriva Diagnostics Tenderfoot ® ). The following data were collected and assessed for each of the 6 groups evaluated: a) number of heel sticks, b) pain score according to the Neonatal Infant Pain Scale (NIPS) and c) need to squeeze the heel. The Ames Minilet™ Lancet device was found to perform by far the worst compared to the five device underexamination: it required the highest number of sticks (mean=3.91; 95% CI: 3.46-4.36), evoked the most intense pain (mean=3.98; 95% CI: 3.77-4.20), and most frequently necessitated squeezing the heel (92.9%; 95% CI: 86.9-96.3). The five devices under examination appeared to be similar in terms of the number of sticks required, but differed slightly in NIPS score and in need to squeeze the heel. The Accriva Diagnostics Tenderfoot ® device demonstrated the greatest efficiency for blood sampling and evoked the least pain. With this device, the metabolic screening test could be performed with a single skin incision in the large majority of infants (98.4%), heel squeezing was limited to only 6.3% of infants, and the NIPS score turns out to be lower than other devices in our study (1.22; 95% CI 1.05-1.39). Copyright © 2017 Elsevier Ltd. All rights reserved.
Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.
Mullins, Garrett R; Bruns, David E
2017-10-01
Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.
ABO blood groups and psychiatric disorders: a Croatian study.
Pisk, Sandra Vuk; Vuk, Tomislav; Ivezić, Ena; Jukić, Irena; Bingulac-Popović, Jasna; Filipčić, Igor
2018-02-15
The prevalence of ABO alleles is different in different populations, and many studies have shown a correlation between the occurrences of some diseases and different genotypes of ABO blood groups. The aim of this study was to determine whether there is a significant association between psychiatric syndromes and ABO blood groups. This case-control study involved 156 psychiatric patients and 303 healthy, unrelated, voluntary blood donors. Genomic DNA was isolated from blood on a QIAcube device using a QIAamp DNA Blood mini QIAcube kit. ABO genotyping on five basic ABO alleles was performed using allele-specific polymerase chain reaction analysis. Compared with healthy subjects, a significantly higher proportion of psychiatric patients had AB blood group (χ 2 =9.359, df=3, p=0.025) and, accordingly, a significantly higher incidence of A1B genotype (χ 2 =8.226, df=3, p=0.042). The odds ratio showed that psychiatric disorders occur almost three times more frequently in carriers of AB group compared to other blood groups. However, no statistically significant difference was found in the distribution of ABO blood groups among patients with different psychiatric diagnoses. Likewise, no correlations were found between ABO blood groups and other characteristics of the psychiatric patients (sex, psychiatric heredity, somatic comorbidity, suicidality). The results of this study support the hypothesis of an association between psychiatric disorders and ABO blood groups. The probability is that psychiatric disorders will occur almost three times more frequently in carriers of AB group compared to other ABO blood groups in the Croatian population.
Sevan'kaev, A V; Khvostunov, I K; Snigireva, G P; Novitskaia, N N; Antoshchina, M M; Fesenko, E V; Vorobtsova, I E; Neronova, E G; Domracheva, E V; Nugis, V Iu; Govorun, R D; Handogina, E K
2013-01-01
The incidence of unstable chromosome aberrations in peripheral blood lymphocytes from unirradiated control subjects was analyzed using cytogenetic data obtained from 9 cytogenetic laboratories located in Moscow, St.-Petersburg, Obninsk, and Dubna (Russia). The objective of this study was to estimate the level and spectrum of spontaneous chromosome aberrations in human lymphocytes. 1140 blood samples were taken from 1112 subjects (594 men and 546 women) aged 1 to 72. The total metaphase number was 466795. The uniform Giemsa method for peripheral blood lymphocyte cultures was used. After counting 466795 metaphases, 4288 chromosomal aberrations of various types were classified. The most frequent types of aberrations were acentrics and chromatid deletions. They made up 90% of the total number of aberrations. The remaining 10% were exchange aberrations. The number of chromosome exchanges (dicentrics and centric rings) was twice the number of chromatid exchanges. Overall, the portion ofcells with chromosomal or (and) chromatid aberrations was 0.89 +/- 0.01%; the frequency of acentrics was 0.29 +/- 0.01; the frequency of dicentrics was 0.046 +/- 0.003; the frequency of unstable chromosome aberrations was 0.35 +/- 0.01; and the frequency of chromatid aberrations was 0.57 +/- 0.01 per 100 cells.
Factors affecting blood sample haemolysis: a cross-sectional study.
Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E
2016-04-01
To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.
Gallo Vaulet, Lucía; Grillová, Linda; Mikalová, Lenka; Casco, Ricardo; Rodríguez Fermepin, Marcelo; Pando, María A.; Šmajs, David
2017-01-01
A total of 54 clinical samples, including genital lesion swabs, whole blood and cerebrospinal fluid from patients diagnosed with syphilis were collected in 2006 and in 2013 in Buenos Aires, Argentina. Treponemal DNA was detected in 43 of the analyzed samples (79.6%) and further analyzed using Sequencing-based molecular typing (SBMT) and Enhanced CDC-typing (ECDCT). By SBMT, 10 different Treponema pallidum subsp. pallidum (TPA) genotypes were found, of which six were related to the TPA SS14 strain, and four to the TPA Nichols strain. The 23S rRNA gene was amplified in samples isolated from 42 patients, and in six of them (14.3%), either the A2058G (four patients, 9.5%) or the A2059G (two patients, 4.8%) mutations were found. In addition to Taiwan, Madagascar and Peru, Argentina is another country where the prevalence of Nichols-like isolates (26.8%) is greater than 10%. PMID:28235102
Gallo Vaulet, Lucía; Grillová, Linda; Mikalová, Lenka; Casco, Ricardo; Rodríguez Fermepin, Marcelo; Pando, María A; Šmajs, David
2017-01-01
A total of 54 clinical samples, including genital lesion swabs, whole blood and cerebrospinal fluid from patients diagnosed with syphilis were collected in 2006 and in 2013 in Buenos Aires, Argentina. Treponemal DNA was detected in 43 of the analyzed samples (79.6%) and further analyzed using Sequencing-based molecular typing (SBMT) and Enhanced CDC-typing (ECDCT). By SBMT, 10 different Treponema pallidum subsp. pallidum (TPA) genotypes were found, of which six were related to the TPA SS14 strain, and four to the TPA Nichols strain. The 23S rRNA gene was amplified in samples isolated from 42 patients, and in six of them (14.3%), either the A2058G (four patients, 9.5%) or the A2059G (two patients, 4.8%) mutations were found. In addition to Taiwan, Madagascar and Peru, Argentina is another country where the prevalence of Nichols-like isolates (26.8%) is greater than 10%.
The prevalence of the metabolic syndrome in Portugal: the PORMETS study.
Raposo, Luís; Severo, Milton; Barros, Henrique; Santos, Ana Cristina
2017-06-08
The PORMETS study was designed to estimate the prevalence of metabolic syndrome and its determinants in the overall and administrative regions of the Portuguese mainland. A cross-sectional study of a representative sample of non-institutionalized Portuguese adults selected from primary health care centres lists including 1695 men and 2309 women was conducted from February 2007 to July 2009. A structured questionnaire was administered, collecting information on personal medical history and socio-demographic and behavioural characteristics. Anthropometrics, blood pressure, and venous blood samples were obtained. Metabolic syndrome was defined according to three operational definitions. The prevalence ratios and their respective 95% confidence intervals were calculated using binomial generalized linear regression, with the log link function. The prevalence rates of metabolic syndrome in this sample of Portuguese adults were 36.5%, 49.6%, and 43.1%, using the Adult Treatment Panel III, International Diabetes Federation and Joint Interim Statement definitions, respectively. The most prevalent feature of metabolic syndrome in this sample was high blood pressure (64.3%) and the lowest was high fasting glucose (24.9%). After adjustment for age and gender, significant differences were observed for the 18 districts of the Portugal mainland. Additionally, metabolic syndrome was significantly more frequent in non-urban areas than in urban ones (p = 0.001). The prevalence of metabolic syndrome was significantly higher in women (p˂0.001) and older participants (p˂0.001), as well as in those who reported being housewives (p = 0.010), retired (p = 0.046) or unemployed (p = 0.024). This study showed that metabolic syndrome is highly prevalent in the Portuguese adult population. Regional differences in the prevalence of this syndrome were observed, and this condition was more common in non-urban areas and less favoured socio-economic categories.
Sodium in Store and Restaurant Food Environments - Guam, 2015.
Jackson, Sandra L; VanFrank, Brenna K; Lundeen, Elizabeth; Uncangco, Alyssa; Alam, Lawrence; King, Sallyann M Coleman; Cogswell, Mary E
2016-05-27
Compared with the United States overall, Guam has higher mortality rates from cardiovascular disease and stroke (1). Excess sodium intake can increase blood pressure and risk for cardiovascular disease (2,3). To determine the availability and promotion of lower-sodium options in the nutrition environment, the Guam Department of Public Health and Social Services (DPHSS) conducted an assessment in September 2015 using previously validated tools adapted to include sodium measures. Stores (N = 114) and restaurants (N = 63) were randomly sampled by region (north, central, and south). Data from 100 stores and 62 restaurants were analyzed and weighted to account for the sampling design. Across the nine product types assessed, lower-sodium products were offered less frequently than regular-sodium products (p<0.001) with <50% of stores offering lower-sodium canned vegetables, tuna, salad dressing, soy sauce, and hot dogs. Lower-sodium products were also less frequently offered in small stores than large (two or more cash registers) stores. Reduced-sodium soy sauce cost more than regular soy sauce (p<0.001) in stores offering both options in the same size bottle. Few restaurants engaged in promotion practices such as posting sodium information (3%) or identifying lower-sodium entrées (1%). Improving the availability and promotion of lower-sodium foods in stores and restaurants could help support healthier eating in Guam.
Physiology and Endocrinology of the Ovarian Cycle in Macaques
Weinbauer, Gerhard F.; Niehoff, Marc; Niehaus, Michael; Srivastav, Shiela; Fuchs, Antje; Van Esch, Eric; Cline, J. Mark
2009-01-01
Macaques provide excellent models for preclinical testing and safety assessment of female reproductive toxicants. Currently, cynomolgus monkeys are the predominant species for (reproductive) toxicity testing. Marmosets and rhesus monkeys are being used occasionally. The authors provide a brief review on physiology and endocrinology of the cynomolgus monkey ovarian cycle, practical guidance on assessment and monitoring of ovarian cyclicity, and new data on effects of social housing on ovarian cyclicity in toxicological studies. In macaques, cycle monitoring is achieved using daily vaginal smears for menstruation combined with cycle-timed frequent sampling for steroid and peptide hormone analysis. Owing to requirements of frequent and timed blood sampling, it is not recommended to incorporate these special evaluations into a general toxicity study design. Marmosets lack external signs of ovarian cyclicity, and cycle monitoring is done by regular determinations of progesterone. Cynomolgus and marmoset monkeys do not exhibit seasonal variations in ovarian activity, whereas such annual rhythm is pronounced in rhesus monkeys. Studies on pair- and group-housed cynomolgus monkeys revealed transient alterations in the duration and endocrinology of the ovarian cycle followed by return to normal cyclicity after approximately six months. This effect is avoided if the animals had contact with each other prior to mingling. These experiments also demonstrated that synchronization of ovarian cycles did not occur. PMID:20852722
2011-01-01
Background Simian Immunodeficiency Viruses (SIVs) are the precursors of Human Immunodeficiency Viruses (HIVs) which have lead to the worldwide HIV/AIDS pandemic. By studying SIVs in wild primates we can better understand the circulation of these viruses in their natural hosts and habitat, and perhaps identify factors that influence susceptibility and transmission within and between various host species. We investigated the SIV status of wild West African chimpanzees (Pan troglodytes verus) which frequently hunt and consume the western red colobus monkey (Piliocolobus badius badius), a species known to be infected to a high percentage with its specific SIV strain (SIVwrc). Results Blood and plasma samples from 32 wild chimpanzees were tested with INNO-LIA HIV I/II Score kit to detect cross-reactive antibodies to HIV antigens. Twenty-three of the samples were also tested for antibodies to 43 specific SIV and HIV lineages, including SIVwrc. Tissue samples from all but two chimpanzees were tested for SIV by PCRs using generic SIV primers that detect all known primate lentiviruses as well as primers designed to specifically detect SIVwrc. Seventeen of the chimpanzees showed varying degrees of cross-reactivity to the HIV specific antigens in the INNO-LIA test; however no sample had antibodies to SIV or HIV strain - and lineage specific antigens in the Luminex test. No SIV DNA was found in any of the samples. Conclusions We could not detect any conclusive trace of SIV infection from the red colobus monkeys in the chimpanzees, despite high exposure to this virus through frequent hunting. The results of our study raise interesting questions regarding the host-parasite relationship of SIVwrc and wild chimpanzees in their natural habitat. PMID:21284842
Koyanagi, Kazuo; Kuo, Christine; Nakagawa, Taku; Mori, Takuji; Ueno, Hideaki; Lorico, Arnulfo R.; Wang, He-Jing; Hseuh, Eddie; O’Day, Steven J.; Hoon, Dave S.B.
2010-01-01
Background Detection of melanoma cells in circulation may be important in assessing tumor progression. The objective of this study was to develop a specific, reliable, multimarker quantitative real-time reverse transcription-PCR (qRT) assay for detecting melanoma cells in patients’ blood. Methods We developed qRT assays for the mRNA of four melanoma-associated markers: MART-1, GalNAc-T, PAX-3, and MAGE-A3. In optimization studies, we tested 17 melanoma cell lines and 49 peripheral blood leukocyte (PBL) samples from volunteers. We performed RNA and melanoma cell dilution studies to assess the detection limits and imprecision of the assays. We measured the mRNAs in blood specimens from 94 melanoma patients [American Joint Committee on Cancer (AJCC) stage I, n = 20; II, n = 20; III, n = 32; IV, n = 22]. Results All markers were frequently detected in melanoma cell lines, whereas none of the markers was detected in PBLs from volunteers. The qRT assay could detect 1 melanoma cell in 107 PBLs in the melanoma cell-dilution studies. Markers were detected in 15%, 30%, 75%, and 86% of melanoma patients with AJCC stage I, II, III, and IV disease, respectively. The number of positive markers and AJCC stage were significantly correlated (Spearman correlation coefficient = 0.58; P <0.0001). Conclusions Multimarker qRT can detect circulating melanoma cells in blood. Measurement of the studied molecular markers in blood may be useful in detection of metastasis and monitoring treatment response of melanoma patients. PMID:15817820
NASA Astrophysics Data System (ADS)
Khoury, David S.; Cromer, Deborah; Best, Shannon E.; James, Kylie R.; Sebina, Ismail; Haque, Ashraful; Davenport, Miles P.
2015-05-01
The best correlate of malaria severity in human Plasmodium falciparum (Pf) infection is the total parasite load. Pf-infected humans could control parasite loads by two mechanisms, either decreasing parasite multiplication, or increasing parasite clearance. However, few studies have directly measured these two mechanisms in vivo. Here, we have directly quantified host clearance of parasites during Plasmodium infection in mice. We transferred labelled red blood cells (RBCs) from Plasmodium infected donors into uninfected and infected recipients, and tracked the fate of donor parasites by frequent blood sampling. We then applied age-based mathematical models to characterise parasite clearance in the recipient mice. Our analyses revealed an increased clearance of parasites in infected animals, particularly parasites of a younger developmental stage. However, the major decrease in parasite multiplication in infected mice was not mediated by increased clearance alone, but was accompanied by a significant reduction in the susceptibility of RBCs to parasitisation.
Laser Transcutaneous Bilirubin Meter: A New Device For Bilirubin Monitoring In Neonatal Jaundice
NASA Astrophysics Data System (ADS)
Hamza, Mostafa; Hamza, Mohammad
1988-06-01
Neonates with jaundice require monitoring of serum bilirubin which should be repeated at frequent intervals. However, taking blood samples from neonates is not always an easy job, plus being an invasive and traumatising procedure with the additional risk of blood loss. In this paper the authors present the theory and design of a new noninvasive device for transcutaneous bilirubinometry, using a differential absorption laser system. The new technique depends upon illuminating the skin of the neonate with radiation from a two wave-length oscillation laser. The choice of the wavelengths follows the principles of optical bilirubinometry. For obtaining more accurate measurements, different pairs of two wave-lengths are incorporated in the design. The presence of hemoglobin is corrected for by appropriate selection of the laser wavelengths. The new design was tested for accuracy and precision using an argon ion laser. Correlation study between serum bilirubin determination by laser transcutaneous bilirubinometry and by American optical bilirubinometer was highly significant.
Lotta, Ingrid A; Matta, Nubia E; Torres, Rubén D; Sandino, Martha Moreno-de; Moncada, Ligia I
2013-04-01
Leucocytozoon spp. infections have been rarely studied in Neotropical countries. The apparently low prevalence of these parasites compared to the Nearctic regions suggests the absence of competent vectors; however, a 21.3% overall prevalence has recently been reported in non-migratory birds from the páramo region of Chingaza National Natural Park (NNP), where Turdus fuscater (Great Thrush) is the species most frequently infected by these parasites. The present study provides the descriptions of the Leucocytozoon spp. detected in Great Thrushes trapped in Chingaza NNP. The parasites were confirmed by microscopic examination and PCR of blood, histopathology was also done. Leucocytozoon dubreuili and L. fringillinarum gametocytes were observed in blood smears. The corresponding cytochrome b (cyt b) lineages obtained of L. fringillinarum were closely related to lineages previously found in individuals infecting turdiid species sampled elsewhere. This is one of the few reports analyzing Leucocytozoon spp. infections in resident birds from a Neotropical country.
Mosalli, Rafat; Elbaz, Mohamed; Paes, Bosco
2013-01-01
Arterial cannulation in neonates is usually performed for frequent blood pressure monitoring and blood sampling. The procedure, while easily executed by skilled neonatal staff, can be associated with serious complications such as vasospasm, thrombosis, embolism, hematoma, infection, peripheral nerve damage, ischemia, and tissue necrosis. Several treatment options are available to reverse vascular induced ischemia and tissue damage. Applied interventions depend on the extent of tissue involvement and whether the condition is progressive and deemed life threatening. Standard, noninvasive measures include immediate catheter removal, limb elevation, and warming the contralateral extremity. Topical vasodilators, anticoagulation, thrombolysis, and surgery are considered secondary therapeutic strategies. A comprehensive literature search indicates that topical nitroglycerin has been utilized for the treatment of tissue ischemia in three preterms with umbilical arterial catheters and four with peripheral arterial lines. We report the first successful use of nitroglycerine ointment in a critically ill preterm infant with ischemic hand changes after brachial artery cannulation. PMID:24251058
Mabrouk, Rostom; Dubeau, François; Bentabet, Layachi
2013-01-01
Kinetic modeling of metabolic and physiologic cardiac processes in small animals requires an input function (IF) and a tissue time-activity curves (TACs). In this paper, we present a mathematical method based on independent component analysis (ICA) to extract the IF and the myocardium's TACs directly from dynamic positron emission tomography (PET) images. The method assumes a super-Gaussian distribution model for the blood activity, and a sub-Gaussian distribution model for the tissue activity. Our appreach was applied on 22 PET measurement sets of small animals, which were obtained from the three most frequently used cardiac radiotracers, namely: desoxy-fluoro-glucose ((18)F-FDG), [(13)N]-ammonia, and [(11)C]-acetate. Our study was extended to PET human measurements obtained with the Rubidium-82 ((82) Rb) radiotracer. The resolved mathematical IF values compare favorably to those derived from curves extracted from regions of interest (ROI), suggesting that the procedure presents a reliable alternative to serial blood sampling for small-animal cardiac PET studies.
Valentiny, Christine; Dirschmid, Harald; Lhotta, Karl
2015-05-28
Streptococcus uberis, the most frequent cause of mastitis in lactating cows, is considered non-pathogenic for humans. Only a few case reports have described human infections with this microorganism, which is notoriously difficult to identify. We report the case of a 75-year-old male haemodialysis patient, who developed a severe foot infection with osteomyelitis and bacteraemia. Both Streptococcus uberis and Staphylococcus aureus were identified in wound secretion and blood samples using mass spectrometry. The presence of Streptococcus uberis was confirmed by superoxide dismutase A sequencing. The patient recovered after amputation of the forefoot and antibiotic treatment with ampicillin/sulbactam. He had probably acquired the infection while walking barefoot on cattle pasture land. This is the first case report of a human infection with Streptococcus uberis with identification of the microorganism using modern molecular technology. We propose that Staphylococcus aureus co-infection was a prerequisite for deep wound and bloodstream infection with Streptococcus uberis.
Ramakrishnaiah, Pushpa Kodipalya; Lakshman, Archana; Aradhya, Sacchidanand Sarvajnamurthy; Veerabhadrappa, Nataraja Holavanahally
2015-01-01
Chronic graft versus host disease (GVHD) is a less frequently seen disease that occurs post solid organ or bone marrow transplantation. Chronic GVHD occurring post blood transfusion is an even more uncommon disease. It can present either as a lichenoid disease or as a sclerodermatous disease involving multiple systems. In this article, we report a case of chronic graft versus host reaction occurring in skin secondary to blood transfusion.
Darton, Thomas C; Zhou, Liqing; Blohmke, Christoph J; Jones, Claire; Waddington, Claire S; Baker, Stephen; Pollard, Andrew J
2017-04-01
Improved diagnostics for typhoid are needed; a typhoid controlled human infection model may accelerate their development and translation. Here, we evaluated a blood culture-PCR assay for detecting infection after controlled human infection with S. Typhi and compared test performance with optimally performed blood cultures. Culture-PCR amplification of blood samples was performed alongside daily blood culture in 41 participants undergoing typhoid challenge. Study endpoints for typhoid diagnosis (TD) were fever and/or bacteraemia. Overall, 24/41 (59%) participants reached TD, of whom 21/24 (86%) had ≥1 positive blood culture (53/674, 7.9% of all cultures) or 18/24 (75%) had ≥1 positive culture-PCR assay result (57/684, 8.3%). A further five non-bacteraemic participants produced culture-PCR amplicons indicating infection; overall sensitivity/specificity of the assay compared to the study endpoints were 70%/65%. We found no significant difference between blood culture and culture-PCR methods in ability to identify cases (12 mismatching pairs, p = 0.77, binomial test). Clinical and stool culture metadata demonstrated that additional culture-PCR amplification positive individuals likely represented true cases missed by blood culture, suggesting the overall attack rate may be 30/41 (73%) rather than 24/41 (59%). Several participants had positive culture-PCR results soon after ingesting challenge providing new evidence for occurrence of an early primary bacteraemia. Overall the culture-PCR assay performed well, identifying extra typhoid cases compared with routine blood culture alone. Despite limitations to widespread field-use, the benefits of increased diagnostic yield, reduced blood volume and faster turn-around-time, suggest that this assay could enhance laboratory typhoid diagnostics in research applications and high-incidence settings. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Continuous glucose monitoring on the ICU using a subcutaneous sensor.
Punke, M A; Decker, C; Wodack, K; Reuter, D A; Kluge, S
2015-06-01
Hypoglycemia is a frequent and feared complication of insulin therapy on the intensive care unit (ICU). Sedated patients in particular are at risk for hypoglycemia due to the absence of clinical symptoms. Furthermore, recent studies point to a correlation between the variability of blood glucose and mortality. Therefore, continuous glucose monitoring has the potential to influence outcome due to a better control of blood glucose in critically ill patients. We evaluated the efficacy, accuracy and safety of a new commercially available subcutaneous continuous glucose monitoring system (sCGM; Sentrino®, Medtronic) in a pilot study in critically ill adult patients. sCGM data were recorded for up to 72 h and values were compared with blood glucose values measured by cassette-based blood gas analyzer (BGA). A total of 14 patients (eight male, six female), with a mean age of 62.1 ± 9.8 years, referred to the ICU after major abdominal surgery were studied. The average simplified acute physiology score (SAPS II) was 35 ± 9. Three patients had known type II diabetes. The average runtime of sensors was 44.1 ± 22.1 h. In comparison to BGA, measurement of blood glucose by sCGM revealed an accuracy of 1.5 mg/dl, and a precision of +34.2 mg/dl to -31.2 mg/dl. Linn's concordance correlation coefficient yielded 0.74 with a 95% confidence interval of 0.68-0.78. No hypoglycemic events, defined as a blood glucose level below 70 mg/dl, occurred during treatment. sCGM monitoring via a subcutaneous sensor demonstrated high accuracy and considerable variability compared to blood gas samples, even in critically ill patients.
Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.
Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin
2015-12-01
Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.
Thurber, Mary Irene; Gamble, Kathryn C; Krebs, Bethany; Goldberg, Tony L
2014-12-01
Frozen blood samples from 13 species of free-ranging birds (n = 65) and captive Chilean flamingos (Phoenicopterus chilensis) (n = 46) housed outdoors in the Chicago area were screened for Plasmodium. With the use of a modified polymerase chain reaction, 20/65 (30.8%) of free-ranging birds and 26/46 (56.5%) of flamingos were classified as positive for this parasite genus. DNA sequencing of the parasite cytochrome b gene in positive samples demonstrated that eight species of free-ranging birds were infected with five different Plasmodium spp. cytochrome b lineages, and all positive Chilean flamingos were infected with Plasmodium spp. cytochrome b lineages most closely related to organisms in the Novyella subgenus. These results show that Chilean flamingos may harbor subclinical malaria infections more frequently than previously estimated, and that they may have increased susceptibility to some Plasmodium species.
Jaenicke, Nathalie J; Pogoda, Werner; Paulke, Alexander; Wunder, Cora; Toennes, Stefan W
2014-09-01
Herbal mixtures contain synthetic cannabinoids, which can cause severe intoxications. Due to the great variety and the changing spectrum of substances on the drug market, prevalence data are limited, and data on prevalence rates of synthetic cannabinoids in forensic cases are not available. The present study was performed to survey the prevalence of synthetic cannabinoids in cases of traffic and criminal offences in the German state Hesse in 2010. The applied analytical method covered all synthetic cannabinoids on the drug market at that time, and with 20% of the blood samples (422 out of 2201) a representative number was reanalyzed. In twelve samples synthetic cannabinoids were identified and a prevalence of 2.8% was estimated. Consumption patterns showed predominantly cases of multi-drug consumption (10 cases); the combination with cannabis or alcohol was frequent (four cases each). The observed deficits were moderate with the exception of aggravation of paranoia in one case. The symptoms were either compatible with the effects of cannabinoid agonists or attributable to alcohol or other drugs found in the blood samples. Our current analytical strategy is to perform such analyses only in cases where use is suspected or where symptoms are not explained by routine toxicological analyses. Hence, the positive rate is rather low highlighting the need to keep up with the developments on the drug market and to establish sensitive screening methods covering a broad range of substances that can be updated fast, e.g., relying on collections of mass spectrometric reference data. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Oyama, Kohta; Khan, Shahzada; Okamoto, Tatsuya; Fujii, Shigemoto; Ono, Katsuhiko; Matsunaga, Tetsuro; Yoshitake, Jun; Sawa, Tomohiro; Tomida, Junko; Kawamura, Yoshiaki
2012-01-01
Helicobacter cinaedi is the most frequently reported enterohepatic Helicobacter species isolated from humans. Earlier research suggested that certain patients with H. cinaedi infection may remain undiagnosed or incorrectly diagnosed because of difficulties in detecting the bacteria by conventional culture methods. Here, we report a nested PCR assay that rapidly detects the cytolethal distending toxin gene (cdt) of H. cinaedi with high specificity and sensitivity. Specificity of the assay was validated by using different species of Helicobacter and Campylobacter, as well as known H. cinaedi-positive and -negative samples. The sensitivity of detection for the cdt gene in the assay was 102 CFU/ml urine or 102 CFU/105 infected RAW 264.7 cells. In an H. cinaedi-infected mouse model, the cdt gene of H. cinaedi was effectively detected via the assay with urine (6/7), stool (2/3), and blood (2/6) samples. Importantly, it detected H. cinaedi in blood, urine, and stool samples from one patient with a suspected H. cinaedi infection and three patients with known infections. The assay was further used clinically to follow up two H. cinaedi-infected patients after antibiotic treatment. Stool samples from these two patients evaluated by nested PCR after antibiotic therapy showed clearance of bacterial DNA. Finally, analysis of stool specimens from healthy volunteers showed occasional positive reactions (4/30) to H. cinaedi DNA, which suggests intestinal colonization by H. cinaedi in healthy subjects. In conclusion, this nested PCR assay may be useful for the rapid diagnosis, antimicrobial treatment evaluation, and epidemiological study of H. cinaedi infection. PMID:23015666
Phylogenetic Analysis of Dengue Virus in Bangkalan, Madura Island, East Java Province, Indonesia.
Sucipto, Teguh Hari; Kotaki, Tomohiro; Mulyatno, Kris Cahyo; Churrotin, Siti; Labiqah, Amaliah; Soegijanto, Soegeng; Kameoka, Masanori
2018-01-01
Dengue virus (DENV) infection is a major health issue in tropical and subtropical areas. Indonesia is one of the biggest dengue endemic countries in the world. In the present study, the phylogenetic analysis of DENV in Bangkalan, Madura Island, Indonesia, was performed in order to obtain a clearer understanding of its dynamics in this country. A total of 359 blood samples from dengue-suspected patients were collected between 2012 and 2014. Serotyping was conducted using a multiplex Reverse Transcriptase-Polymerase Chain Reaction and a phylogenetic analysis of E gene sequences was performed using the Bayesian Markov chain Monte Carlo (MCMC) method. 17 out of 359 blood samples (4.7%) were positive for the isolation of DENV. Serotyping and the phylogenetic analysis revealed the predominance of DENV-1 genotype I (9/17, 52.9%), followed by DENV-2 Cosmopolitan type (7/17, 41.2%) and DENV-3 genotype I (1/17, 5.9%) . DENV-4 was not isolated. The Madura Island isolates showed high nucleotide similarity to other Indonesian isolates, indicating frequent virus circulation in Indonesia. The results of the present study highlight the importance of continuous viral surveillance in dengue endemic areas in order to obtain a clearer understanding of the dynamics of DENV in Indonesia.
Grandjean, P; Weihe, P; Needham, L L; Burse, V W; Patterson, D G; Sampson, E J; Jørgensen, P J; Vahter, M
1995-10-01
Human transition milk was sampled from 88 mothers at the Faroe Islands, where the seafood diet includes pilot whale meat and blubber. Milk mercury concentrations (median, 2.45 micrograms/liter) were significantly associated with mercury concentrations in cord blood and with the frequency of pilot whale dinners during pregnancy. Milk selenium concentrations (mean, 19.1 micrograms/liter) correlated significantly with concentrations in cord blood but not with seafood consumption. Arsenic concentrations were very low. Twenty-four of the milk samples were separated into four pools based on fish intake and milk mercury concentrations. The polychlorinated biphenyl (PCB) concentrations (1.8-3.5 micrograms/g lipid) were high and mainly due to congener numbers 153, 180, and 138. One pool contained a congener 77 concentration of 1380 ppt, which is the highest ever reported in a human specimen for a coplanar PCB. The highest PCB concentrations were seen in the pools from women who had eaten frequent whale dinners and whose milk contained high mercury concentrations. The concentrations of chlorinated dibenzo-p-dioxins and furans were not similarly elevated. Given the advantages associated with breast-feeding, advice to nursing mothers in this population should take into regard the possible risks associated with long-term exposure to milk contaminants.
[Nutritional status of street children in the district of Manga (Burkina Faso)].
Diongue, M; Ndiaye, P; Yameogo, I; Faye, B F; Dia, A Tal; Diousse, P
2014-01-01
Malnutrition is an important indicator of development, and its consequences in children and adolescents produce a serious socioeconomic burden. Children living on the street are more vulnerable than others. Thus, our objective was to analyze the nutritional status of children living on the streets of Manga, through a cross-sectional and analytical study. The snowball technique was used for sampling. Data came from individual interviews, blood samples and medical examinations. Of the 237 children studied, 84.8% were boys; the overall mean age was 11.5 years, and 72.6% were adolescents (aged 10 to 17 years). Growth retardation (15.9%) predominated among the children aged 4 to 9 years, while a weight deficit (27.9%) was most common among those aged 10 to 17. Half of the children (50.2%) with blood tests (N = 119) had anemia. There was a link between anemia and underweight (p = 0.0145). Children who ate at least three times a day were 2.63 times less likely to be anemic (p<0.001). Factors associated with anemia (p<0.005) included survival activities. We frequently found nutritional deficits and anemia in these children. A targeted nutritional program would be a good entry point for their successful reintegration..
Silva, Luciete Almeida; Lima, Kátia Maria da Silva; Fernandes, Ormezinda Celeste Cristo; Balassiano, Ilana Teruszkin; Avelar, Kátia Eliane Santos; Jesus, Michele Silva de
2016-01-01
Leptospirosis is caused by a bacterium of the genus Leptospira. This study aimed at investigating the seroprevalence of and risk factors for leptospirosis in humans in Manaus, State of Amazonas. Interviews were performed, and 1,000 blood serum samples were examined using a microscopic agglutination test. Forty-three cases were positive; there were 10 serotypes, with coagglutination in 8 cases. The most frequently occurring serotypes were Icterohaemorrhagiae (20.7%), Cynopteri (20.7%), Australis (18.8%), and Copenhageni (16.9%), and the Midwest (54.7%) and South (23.8%) had the most cases; these areas lack basic sanitation. Disease occurrence might be reduced through improved basic infrastructural conditions.
Glycemic, insulinemic and incretin responses after oral trehalose ingestion in healthy subjects.
Yoshizane, Chiyo; Mizote, Akiko; Yamada, Mika; Arai, Norie; Arai, Shigeyuki; Maruta, Kazuhiko; Mitsuzumi, Hitoshi; Ariyasu, Toshio; Ushio, Shimpei; Fukuda, Shigeharu
2017-02-06
Trehalose is hydrolyzed by a specific intestinal brush-border disaccharidase (trehalase) into two glucose molecules. In animal studies, trehalose has been shown to prevent adipocyte hypertrophy and mitigate insulin resistance in mice fed a high-fat diet. Recently, we found that trehalose improved glucose tolerance in human subjects. However, the underlying metabolic responses after trehalose ingestion in humans are not well understood. Therefore, we examined the glycemic, insulinemic and incretin responses after trehalose ingestion in healthy Japanese volunteers. In a crossover study, 20 fasted healthy volunteers consumed 25 g trehalose or glucose in 100 mL water. Blood samples were taken frequently over the following 3 h, and blood glucose, insulin, active gastric inhibitory polypeptide (GIP) and active glucagon-like peptide-1 (GLP-1) levels were measured. Trehalose ingestion did not evoke rapid increases in blood glucose levels, and had a lower stimulatory potency of insulin and active GIP secretion compared with glucose ingestion. Conversely, active GLP-1 showed higher levels from 45 to 180 min after trehalose ingestion as compared with glucose ingestion. Specifically, active GIP secretion, which induces fat accumulation, was markedly lower after trehalose ingestion. Our findings indicate that trehalose may be a useful saccharide for good health because of properties that do not stimulate rapid increases in blood glucose and excessive secretion of insulin and GIP promoting fat accumulation.
Rakanović-Todić, Maida; Burnazović-Ristić, Lejla; Ibrulj, Slavka; Mulbegović, Nedžad
2014-05-01
Endogenious opiod met-enkephalin throughout previous research manifested cytoprotective and anti-inflammatory effects. Previous research suggests that met-enkephalin has cytogenetic effects. Reducement in the frequency of structural chromosome aberrations as well as a suppressive effect on lymphocyte cell cycle is found. It also reduces apoptosis in the blood samples of the patients with immune-mediated diseases. Met-enkephalin exerts immunomodulatory properties and induces stabilization of the clinical condition in patients with multiple Sclerosis (MS). The goal of the present research was to evaluate met-enkephalin in vitro effects on the number and type of chromosome aberrations in the peripheral blood lymphocytes of patients with MS. Our research detected disappearance of ring chromosomes and chromosome fragmentations in the cultures of the peripheral blood lymphocytes treated with met-enkephalin (1.2 μg/mL). However, this research did not detect any significant effects of met-enkephalin on the reduction of structural chromosome aberrations and disappearance of dicentric chromosomes. Chromosomes with the greatest percent of inclusion in chromosome aberrations were noted as: chromosome 1, chromosome 2 and chromosome 9. Additionally, we confirmed chromosome 14 as the most frequently included in translocations. Furthermore, met-enkephalin effects on the increase of the numerical aberrations in both concentrations applied were detected. Those findings should be interpreted cautiously and more research in this field should be conducted.
NASA Astrophysics Data System (ADS)
Darvin, Maxim E.; Magnussen, Björn; Lademann, Juergen; Köcher, Wolfgang
2016-09-01
Non-invasive measurement of carotenoid antioxidants in human skin is one of the important tasks to investigate the skin physiology in vivo. Resonance Raman spectroscopy and reflection spectroscopy are the most frequently used non-invasive techniques in dermatology and skin physiology. In the present study, an improved method based on multiple spatially resolved reflection spectroscopy (MSRRS) was introduced. The results obtained were compared with those obtained using the ‘gold standard’ resonance Raman spectroscopy method and showed strong correlations for the total carotenoid concentration (R = 0.83) as well as for lycopene (R = 0.80). The measurement stability was confirmed to be better than 10% within the total temperature range from 5 °C to + 30 °C and pressure contact between the skin and the MSRRS sensor from 800 Pa to 18 000 Pa. In addition, blood samples taken from the subjects were analyzed for carotenoid concentrations. The MSRRS sensor was calibrated on the blood carotenoid concentrations resulting in being able to predict with a correlation of R = 0.79. On the basis of blood carotenoids it could be demonstrated that the MSRRS cutaneous measurements are not influenced by Fitzpatrick skin types I-VI. The MSRRS sensor is commercially available under the brand name biozoom.
Tien, Yu En; Huang, Wen-Chuan; Kuo, Hui-Yuan; Tai, Lily; Uang, Yow-Shieng; Chern, Wendy H; Huang, Jin-Ding
2017-11-01
Nalbuphine is a semi-synthetic opioid indicated for the relief of moderate to severe pain. Its short half-life requires frequent injections in clinical practice, resulting in a greater incidence of adverse events. A prodrug of nalbuphine has been developed, dinalbuphine sebacate (DNS), dissolved in a simple oil-based injectable formulation, which could deliver and maintain an effective blood level of nalbuphine. An open-label, prospective, two-period study was performed in healthy volunteers to verify the extended blood concentration profile of nalbuphine. Twelve healthy Taiwanese were randomized to receive an intramuscular injection of 20 mg nalbuphine HCl and 150 mg DNS sequentially with a washout period of 5 days. To prevent DNS hydrolysis during sample analysis, the effect of four esterase inhibitors was evaluated in the quantitation of DNS in human whole blood and thenoyltrifluoroacetone was chosen. The bioavailability of nalbuphine from intramuscularly injected DNS relative to that from nalbuphine HCl was 85.4%. The mean absorption time of nalbuphine from DNS was 145.2 h. It took approximately 6 days for the complete release of DNS into the blood stream where DNS was rapidly hydrolysed to nalbuphine; suggesting a single injection of 150 mg DNS in our extended-release formulation could provide long-lasting pain relief. Copyright © 2017 John Wiley & Sons, Ltd.
Ribeiro, Antonio L; Sabino, Ester C; Marcolino, Milena S; Salemi, Vera M C; Ianni, Barbara M; Fernandes, Fábio; Nastari, Luciano; Antunes, André; Menezes, Márcia; Oliveira, Cláudia Di Lorenzo; Sachdev, Vandana; Carrick, Danielle M; Busch, Michael P; Murphy, Eduard L
2013-01-01
Blood donor screening leads to large numbers of new diagnoses of Trypanosoma cruzi infection, with most donors in the asymptomatic chronic indeterminate form. Information on electrocardiogram (ECG) findings in infected blood donors is lacking and may help in counseling and recognizing those with more severe disease. To assess the frequency of ECG abnormalities in T.cruzi seropositive relative to seronegative blood donors, and to recognize ECG abnormalities associated with left ventricular dysfunction. The study retrospectively enrolled 499 seropositive blood donors in São Paulo and Montes Claros, Brazil, and 483 seronegative control donors matched by site, gender, age, and year of blood donation. All subjects underwent a health clinical evaluation, ECG, and echocardiogram (Echo). ECG and Echo were reviewed blindly by centralized reading centers. Left ventricular (LV) dysfunction was defined as LV ejection fraction (EF)<0.50%. Right bundle branch block and left anterior fascicular block, isolated or in association, were more frequently found in seropositive cases (p<0.0001). Both QRS and QTc duration were associated with LVEF values (correlation coefficients -0.159,p<0.0003, and -0.142,p = 0.002) and showed a moderate accuracy in the detection of reduced LVEF (area under the ROC curve: 0.778 and 0.790, both p<0.0001). Several ECG abnormalities were more commonly found in seropositive donors with depressed LVEF, including rhythm disorders (frequent supraventricular ectopic beats, atrial fibrillation or flutter and pacemaker), intraventricular blocks (right bundle branch block and left anterior fascicular block) and ischemic abnormalities (possible old myocardial infarction and major and minor ST abnormalities). ECG was sensitive (92%) for recognition of seropositive donors with depressed LVEF and had a high negative predictive value (99%) for ruling out LV dysfunction. ECG abnormalities are more frequent in seropositive than in seronegative blood donors. Several ECG abnormalities may help the recognition of seropositive cases with reduced LVEF who warrant careful follow-up and treatment.
Salivary creatinine and urea analysis in patients with chronic kidney disease: a case control study.
Lasisi, Taye Jemilat; Raji, Yemi Raheem; Salako, Babatunde Lawal
2016-01-16
Many metabolic changes develop in patients with chronic kidney disease which often necessitate frequent biochemical analysis of blood. Saliva analysis as an alternative to blood has many advantages. The aims of this study were to evaluate levels of salivary creatinine and urea in patients with chronic kidney disease in comparison to healthy individuals; to determine correlation between salivary creatinine/urea and blood creatinine/urea and to evaluate the diagnostic potential of saliva. A case control study, involving 50 patients with late stage chronic kidney disease and 49 healthy individuals as control. Blood and saliva samples were analyzed for urea and creatinine levels. Data are presented as median with interquartile range and compared using Independent Samples Mann Whitney U test. Correlation between plasma and salivary creatinine as well as urea was determined using Spearman's correlation test. Receiver operating characteristics (ROC) analysis was done to determine the diagnostic ability of salivary creatinine and urea and cut-off values were established. Median salivary creatinine levels were 2.60 mg/dl and 0.20 mg/dl while median salivary urea levels were 92.00 mg/dl and 20.50 mg/dl in patients with chronic kidney disease and controls respectively. Salivary levels of creatinine and urea were significantly elevated in chronic kidney disease patients (p < 0.001). In addition, there was positive correlation between blood and salivary creatinine as well as urea levels. Total areas under the curve for salivary creatinine and urea were 0.97 and 0.89 respectively. Cut-off values for salivary creatinine and urea were 0.55 mg/dl and 27.50 mg/dl respectively which gave sensitivity and specificity of 94 % and 85 % for creatinine; as well as 86 % and 93 % for urea. Findings of this study suggest that analysis of salivary creatinine and urea in patients with chronic kidney disease reflects their levels in blood. Hence, salivary creatinine and urea could be used as diagnostic biomarkers of chronic kidney disease.
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.
Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi
2013-02-01
To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.
Kieninger, M; Zech, N; Mulzer, Y; Bele, S; Seemann, M; Künzig, H; Schneiker, A; Gruber, M
2015-05-01
Point of care testing with blood gas analysis (BGA) is an important factor for intensive care medicine. Continuous efforts to optimize workflow, improve safety for the staff and avoid preanalytical mistakes are important and should reflect quality management standards. In a prospective observational study it was investigated whether the implementation of a new system for BGA using labeled syringes and automated processing of the specimens leads to improvements compared to the previously used procedure. In a 4-week test period the time until receiving the final results of the BGA with the standard method used in the clinical routine (control group) was compared to the results in a second 4-week test period using the new labeled syringes and automated processing of the specimens (intervention group). In addition, preanalytical mistakes with both systems were checked during routine daily use. Finally, it was investigated whether a delay of 10 min between taking and analyzing the blood samples alters the results of the BGA. Preanalytical errors were frequently observed in the control group where non-deaerated samples were recorded in 87.3 % but in the intervention group almost all samples (98.9 %) were correctly deaerated. Insufficient homogenization due to omission of manual pivoting was seen in 83.2 % in the control group and in 89.9 % in the intervention group; however, in the intervention group the samples were homogenized automatically during the further analytical process. Although a survey among the staff revealed a high acceptance of the new system and a subjective improvement of workflow, a measurable gain in time after conversion to the new procedure could not be seen. The mean time needed for a complete analysis process until receiving the final results was 244 s in the intervention group and 201 s in the control group. A 10-min delay between taking and analyzing the blood samples led to a significant and clinically relevant elevation of the values for partial pressure of oxygen (pO2) in both groups compared to the results when analyzing the samples immediately (118.4 vs. 148.6 mmHg in the control group and 115.3 vs. 123.7 mmHg in the intervention group). When using standard syringes the partial pressure of carbon dioxide (pCO2) was significantly lower (40.5 vs. 38.3 mmHg) whereas no alterations were seen when using the labeled syringes. The implementation of a new BGA system with labeled syringes and automated processing of the specimens was possible without any difficulties under daily clinical routine conditions in this 10-bed intensive care unit (ICU). A gain of time could not be measured but a reduction in preanalytical errors using the labeled syringes with automated processing was found. Delayed analysis of blood samples can lead to significant changes in pO2 and pCO2 depending on the type of syringe used.
Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea
2011-01-01
Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280
Pandey, Khushaboo; Dubey, Rama Shankar; Prasad, Bhim Bali
2016-03-01
The most important objectives that are frequently found in bio-analytical chemistry involve applying tools to relevant medical/biological problems and refining these applications. Developing a reliable sample preparation step, for the medical and biological fields is another primary objective in analytical chemistry, in order to extract and isolate the analytes of interest from complex biological matrices. Since, main inborn errors of metabolism (IEM) diagnosable through uracil analysis and the therapeutic monitoring of toxic 5-fluoruracil (an important anti-cancerous drug) in dihydropyrimidine dehydrogenase deficient patients, require an ultra-sensitive, reproducible, selective, and accurate analytical techniques for their measurements. Therefore, keeping in view, the diagnostic value of uracil and 5-fluoruracil measurements, this article refines several analytical techniques involved in selective recognition and quantification of uracil and 5-fluoruracil from biological and pharmaceutical samples. The prospective study revealed that implementation of molecularly imprinted polymer as a solid-phase material for sample preparation and preconcentration of uracil and 5-fluoruracil had proven to be effective as it could obviates problems related to tedious separation techniques, owing to protein binding and drastic interferences, from the complex matrices in real samples such as blood plasma, serum samples.
[Antimicrobial resistance in Germany. Four years of antimicrobial resistance surveillance (ARS)].
Noll, I; Schweickert, B; Abu Sin, M; Feig, M; Claus, H; Eckmanns, T
2012-11-01
In 2007, the Robert Koch Institute established the infrastructure for the national Antimicrobial Resistance Surveillance (ARS) system. Laboratories submit data of routine susceptibility testing of clinical samples from hospitals as well as from outpatient care settings in a standardized format to the Robert Koch Institute for central processing. The database for the period 2008-2011 comprises data of about 1.3 million samples from patients in hospital care and almost 800,000 samples from outpatients. Based on SIR interpretations of susceptibility, the trends of methicillin resistance of Staphylococcus aureus (MRSA) and cefotaxime non-susceptibility as an indicator of extended-spectrum beta-lactamases (ESBL) of Escherichia coli and Klebsiella pneumoniae were analyzed for four care settings or categories: hospital care, outpatient care, intensive care units, and isolates from blood cultures. After constant high levels of above 20%, the proportion of MRSA isolates showed a decline for the first time from 2010 to 2011 in hospital care overall, in intensive care units as well as in blood cultures; in outpatient care, MRSA proportions of about 13% were observed. Within the observed period, non-susceptibility to cefotaxime as an indicator of ESBL in E. coli showed an increasing trend in hospital care at a level above 10% in intensive care units, while cefotaxime non-susceptibility in K. pneumoniae was more frequent but without any trend. In outpatient care, the proportions of cefotaxime non-susceptibility increased year by year in both species resulting in nearly a doubling to 6%.
Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T
2015-12-01
To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.
[Point-of-care-testing--the intensive care laboratory].
Müller, M M; Hackl, W; Griesmacher, A
1999-01-01
After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by nontrained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors' opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.
A Strategic Planning Tool for Increasing African American Blood Donation.
Singleton, Ashley; Spratling, Regena
2018-05-01
Historically, African Americans (AAs) have been underrepresented as blood donors. Having a lack of racially diverse blood donors contributes to transfusion complications, particularly in patients with sickle cell disease, who are both disproportionately AA and the recipients of frequent transfusions. Increasing AA blood donation is a complex public health issue. This review article serves to fill a gap in translating research regarding known hindrances and facilitators of AA blood donation to improve real-world donation practice and ultimately, patient outcomes. We incorporate findings from a literature review to develop a tool that blood centers, provider organizations, and patient advocacy groups can use to aid strategic planning efforts aimed at increasing AA blood donation.
Usability of Immunohistochemistry in Forensic Samples With Varying Decomposition.
Lesnikova, Iana; Schreckenbach, Marc Niclas; Kristensen, Maria Pihlmann; Papanikolaou, Liv Lindegaard; Hamilton-Dutoit, Stephen
2018-05-24
Immunohistochemistry (IHC) is an important diagnostic tool in anatomic and surgical pathology but is used less frequently in forensic pathology. Degradation of tissue because of postmortem decomposition is believed to be a major limiting factor, although it is unclear what impact such degradation actually has on IHC staining validity. This study included 120 forensic autopsy samples of liver, lung, and brain tissues obtained for diagnostic purposes. The time from death to autopsy ranged between 1 and more than 14 days. Samples were prepared using the tissue microarray technique. The antibodies chosen for the study included KL1 (for staining bile duct epithelium), S100 (for staining glial cells and myelin), vimentin (for endothelial cells in cerebral blood vessels), and CD45 (for pulmonary lymphocytes). Slides were evaluated by light microscopy. Immunohistochemistry reactions were scored according to a system based on the extent and intensity of the positive stain. An overall correlation between the postmortem interval and the IHC score for all tissue samples was found. Samples from decedents with a postmortem interval of 1 to 3 days showed positive staining with all antibodies, whereas samples from decedents with a longer postmortem interval showed decreased staining rates. Our results suggest that IHC analysis can be successfully used for postmortem diagnosis in a range of autopsy samples showing lesser degrees of decomposition.
Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun
2016-12-01
In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p < 0.001). Image-derived radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left ventricle after 30 min of FBPA injection was minimal. We conclude that the image-derived T/B ratio can be reliably used by setting the VOI on the left ventricle at 30 min after FBPA administration and correcting for underestimation due to partial volume effect and reduction of FBPA blood radioactivity.
Pająk, Andrzej; Jankowski, Piotr; Kotseva, Kornelia; Heidrich, Jan; de Smedt, Delphine; De Bacquer, Dirk
2013-04-01
To assess in coronary heart disease (CHD) patients: (1) differences in the prevalence of depression and anxiety between samples selected from 22 countries; (2) the association of depression and anxiety with age, education, diagnostic category, favourable behaviours, use of cardioprotective drugs, and reaching the secondary prevention treatment targets. Cross-sectional study. The study group consisted of 8580 patients from 22 European countries examined at least 6 months after hospitalization due to CHD. Depression and anxiety were assessed using Hospital Anxiety and Depression Scale (HADS). Prevalence of depression (HADS depression score ≥ 8) varied from 8.2% to 35.7% in men and from 10.3% to 62.5% in women. Prevalence of anxiety (HADS anxiety score ≥ 8) varied from 12.0% to 41.8% in men and from 21.5% to 63.7% in women. Older age, female sex, low education, and no history of invasive treatment were associated with more frequent depression and anxiety. Depression and anxiety were associated with less frequent modification of lifestyle. Depression was related with body mass index, waist circumference, fasting glucose, and more frequent self-reported diabetes but not with reaching the treatment targets for blood pressure and lipids. High prevalence of depression and anxiety in CHD patients, and relation with less frequent lifestyle modification, call to integrate methods of identification and minimizing unfavourable effects of depression and anxiety into the cardiac rehabilitation and prevention programmes.
Shi, Xuqin; Tang, Yuping; Zhu, Huaxu; Li, Weixia; Li, Zhenhao; Li, Wei; Duan, Jin-ao
2014-01-01
Astragali Radix (AR) and Angelicae Sinensis Radix (ASR) were frequently combined and used in China as herbal pair called as Danggui Buxue Decoction (DBD) for treatment of blood deficiency syndrome, such as women's ailments. This study is to investigate the tissue distribution profiles of five major bio-active constituents (ferulic acid, caffeic acid, calycosin-7-O-β-glucoside, ononin and astragaloside IV) in DBD after oral administration of DBD in blood deficiency rats, and to compare the difference between normal and blood deficiency rats. The blood deficiency rats were induced by bleeding from orbit at the dosages of 5.0mLkg(-1) every day, and the experimental period was 12 days. At the finally day of experimental period, both normal and blood deficiency rats were orally administrated with DBD, and then the tissues samples were collected at different time points. Ferulic acid, caffeic acid, calycosin-7-O-β-glucoside, ononin and astragaloside IV in different tissues were detected simultaneously by UPLC-TQ/MS, and the histograms were drawn. The results showed that the overall trend was CLiver>CKidney>CHeart>CSpleen>CLung, CC-30min>CM-30min>CM-60min>CC-5min>CM-5min>CC-60min>CM-240min>CC-240min. The contents of the detected compounds in liver were more than that in other tissues no matter in normal or blood deficiency rats. Compared to normal rats, partial contents of the compounds in blood deficiency rats' tissues at different time points had significant difference (P<0.05). This study was the first report about tissue distribution investigation in blood deficiency animals which is conducted by bleeding. And the results demonstrated that the five DBD components in normal and blood deficiency rats had obvious differences in some organs and time points, suggesting that the blood flow and perfusion rate of the organ were altered in blood deficiency animals. Copyright © 2013 Elsevier B.V. All rights reserved.
ABO and Rh blood group genotypes in a cohort of Saudi stem cell donors.
Alzahrani, M; Jawdat, D; Alaskar, A; Cereb, N; Hajeer, A H
2018-04-01
The ABO and rhesus (Rh) blood group antigens are the most frequently studied genetic markers in a large group of people. Blood type frequencies vary in different racial/ethnic groups. Our objective was to investigate the distribution of the ABO and rhesus (Rh) blood groups by molecular typing method in a population of Saudi stem cell donors. Our data indicate that the most common blood group in our population is group O followed by group A then group B, and finally, the least common is group AB. © 2018 John Wiley & Sons Ltd.
European trauma guideline compliance assessment: the ETRAUSS study.
Hamada, Sophie Rym; Gauss, Tobias; Pann, Jakob; Dünser, Martin; Leone, Marc; Duranteau, Jacques
2015-12-08
Haemorrhagic shock is the leading cause of preventable death in trauma patients. The 2013 European trauma guidelines emphasise a comprehensive, multidisciplinary, protocol-based approach to trauma care. The aim of the present Europe-wide survey was to compare 2015 practice with the 2013 guidelines. A group of members of the Trauma and Emergency Medicine section of the European Society of Intensive Care Medicine developed a 50-item questionnaire based upon the core recommendations of the 2013 guidelines, employing a multistep approach. The questionnaire covered five fields: care structure and organisation, haemodynamic resuscitation targets, fluid management, transfusion and coagulopathy, and haemorrhage control. The sampling used a two-step approach comprising initial purposive sampling of eminent trauma care providers in each European country, followed by snowball sampling of a maximum number of trauma care providers. A total of 296 responses were collected, 243 (81 %) from European countries. Those from outside the European Union were excluded from the analysis. Approximately three-fourths (74 %) of responders were working in a designated trauma centre. Blunt trauma predominated, accounting for more than 90 % of trauma cases. Considerable heterogeneity was observed in all five core aspects of trauma care, along with frequent deviations from the 2013 guidelines. Only 92 (38 %) of responders claimed to comply with the recommended systolic blood pressure target, and only 81 (33 %) responded that they complied with the target pressure in patients with traumatic brain injury. Crystalloid use was predominant (n = 209; 86 %), and vasopressor use was frequent (n = 171, 76 %) but remained controversial. Only 160 respondents (66 %) declared that they used tranexamic acid always or often. This is the first European trauma survey, to our knowledge. Heterogeneity is significant across centres with regard to the clinical protocols for trauma patients and as to locally available resources. Deviations from guidelines are frequent, differ from region to region and are dependent upon specialty training. Further efforts are required to provide consensus guidelines and to improve their implementation across European countries.
Abras, Alba; Gállego, Montserrat; Muñoz, Carmen; Juiz, Natalia A; Ramírez, Juan Carlos; Cura, Carolina I; Tebar, Silvia; Fernández-Arévalo, Anna; Pinazo, María-Jesús; de la Torre, Leonardo; Posada, Elizabeth; Navarro, Ferran; Espinal, Paula; Ballart, Cristina; Portús, Montserrat; Gascón, Joaquim; Schijman, Alejandro G
2017-04-01
Trypanosoma cruzi, the causative agent of Chagas disease, is divided into six Discrete Typing Units (DTUs): TcI-TcVI. We aimed to identify T. cruzi DTUs in Latin-American migrants in the Barcelona area (Spain) and to assess different molecular typing approaches for the characterization of T. cruzi genotypes. Seventy-five peripheral blood samples were analyzed by two real-time PCR methods (qPCR) based on satellite DNA (SatDNA) and kinetoplastid DNA (kDNA). The 20 samples testing positive in both methods, all belonging to Bolivian individuals, were submitted to DTU characterization using two PCR-based flowcharts: multiplex qPCR using TaqMan probes (MTq-PCR), and conventional PCR. These samples were also studied by sequencing the SatDNA and classified as type I (TcI/III), type II (TcII/IV) and type I/II hybrid (TcV/VI). Ten out of the 20 samples gave positive results in the flowcharts: TcV (5 samples), TcII/V/VI (3) and mixed infections by TcV plus TcII (1) and TcV plus TcII/VI (1). By SatDNA sequencing, we classified the 20 samples, 19 as type I/II and one as type I. The most frequent DTU identified by both flowcharts, and suggested by SatDNA sequencing in the remaining samples with low parasitic loads, TcV, is common in Bolivia and predominant in peripheral blood. The mixed infection by TcV-TcII was detected for the first time simultaneously in Bolivian migrants. PCR-based flowcharts are very useful to characterize DTUs during acute infection. SatDNA sequence analysis cannot discriminate T. cruzi populations at the level of a single DTU but it enabled us to increase the number of characterized cases in chronically infected patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Spectral feature characterization methods for blood stain detection in crime scene backgrounds
NASA Astrophysics Data System (ADS)
Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.
2016-05-01
Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.
Lead in candy consumed and blood lead levels of children living in Mexico City.
Tamayo y Ortiz, Marcela; Téllez-Rojo, Martha María; Hu, Howard; Hernández-Ávila, Mauricio; Wright, Robert; Amarasiriwardena, Chitra; Lupoli, Nicola; Mercado-García, Adriana; Pantic, Ivan; Lamadrid-Figueroa, Héctor
2016-05-01
Recent studies have shown that lead exposure continues to pose a health risk in Mexico. Children are a vulnerable population for lead effects and Mexican candy has been found to be a source of exposure in children. There are no previous studies that estimates lead concentrations in candy that children living in Mexico City consume and its association with their blood lead level. To evaluate whether there is an association between reported recent consumption of candies identified to have lead, and blood lead levels among children in Mexico City. A subsample of 171 children ages 2-6 years old, from the Early Life Exposure in Mexico to Environmental Toxicants (ELEMENT) cohort study was assessed between June 2006 and July 2007. The candy reported most frequently were analyzed for lead using ICP-MS. The total weekly intake of lead through the consumption of candy in the previous week was calculated. Capillary blood lead levels (BLL) were measured using LeadCare (anodic stripping voltammetry). Lead concentrations ≥0.1ppm, the FDA permitted level (range: 0.13-0.7ppm) were found in 6 samples out of 138 samples from 44 different brands of candy. Median BLL in children was 4.5µg/dl. After adjusting for child's sex, age, BMI, maternal education & occupation, milk consumption, sucking the candy wrapper, use of lead-glazed pottery, child exposure behavior, living near a lead exposure site and use of folk remedies, an increase of 1µg of lead ingested through candy per week was associated with 3% change (95% CI: 0.1%, 5.2%) in BLL. Although lead concentrations in candy were mostly below the FDA permitted level, high lead concentrations were detected in 4% of the candy samples and 12% of brands analyzed. Although candy intake was modestly associated with children's BLL, lead should not be found in consumer products, especially in candy that children can consume due to the well documented long-lasting effect of lead exposure. Copyright © 2016 Elsevier Inc. All rights reserved.
[Detection and analysis of anti-Rh blood group antibodies].
Wu, Yuan-jun; Wu, Yong; Chen, Bao-chan; Liu, Yan
2008-06-01
To study the prevalence and distribution of anti-Rh blood group antibodies in Chinese population and its clinical significance. Irregular antibodies were screened and identified by Microcolum Gel Coomb's test. For those identified as positive anti-Rh samples, monoclonal antibodies (anti-D, -C, -c, -E and -e) were used to identify the specific antigen and confirm the accuracy of the irregular antibody tests. The titers, Ig-types and 37 Degrees Celsius-reactivity were tested to confirm its clinical significance. For evaluation of the origin of irregular antibodies, histories of pregnancy and transfusion were reviewed. For the newborns who had positive antibodies, their mothers were tested simultaneously to confirm the origin of the antibodies. 47 out of 54 000 (0.087%) patients were identified as positive with Rh blood group antibodies.Of them, 27 cases had history of pregnancy, 13 had transfusion and 1 had the histories of both. 6 newborns had antibodies derived form their mothers. The specificity of the antibody was as follows: 29 with anti-E (61.70%), 8 with anti-D (17.02%), anti-cE 5(10.64%), 4 with anti-c (8.51%) and 1 with anti-C (2.13%). All the 47 Rh blood group antibodies were IgG or IgG+IgM, and were reactive to red blood cells with corresponding antigens at 37 Degrees Celsius, with a highest titer of 1:4 096. The prevalence of Rh antibodies is lower in Chinese population as compared with that in White population.Of all the antibodies, anti-E is most frequently identified and anti-D was declining. Alloimmunization by pregnancy and transfusion is the major cause of Rh antibody production. Rh blood group antibodies derived from mothers are the major cause of Non-ABO-HDN.
Glenn, Jolene A.; Emmenegger, Eveline J.; Grady, Courtney A.; Roon, Sean R.; Gregg, Jacob L.; Conway, Carla M.; Winton, James R.; Hershberger, Paul K.
2012-01-01
Viral erythrocytic necrosis (VEN) is a condition that affects marine and anadromous fish species, including herrings and salmonids, in the Atlantic and Pacific oceans. Infection is frequently associated with severe anemia and causes episodic mortality among wild and hatchery fish when accompanied by additional stressors; VEN can be presumptively diagnosed by (1) light microscopic identification of a single characteristic—a round, magenta-colored, 0.8-μm-diameter inclusion body (IB) within the cytoplasm of erythrocytes and their precursors on Giemsa-stained blood films; or (2) observation (via transmission electron microscopy [TEM]) of the causative iridovirus, erythrocytic necrosis virus (ENV), within erythrocytes or their precursors. To better understand the kinetics of VEN, specific-pathogen-free Pacific herring Clupea pallasii were infected with ENV by intraperitoneal injection. At 1, 4, 7, 10, 14, 21, and 28 d postexposure, samples of blood, spleen, and kidney were collected and assessed (1) via light microscopy for the number of intracytoplasmic IBs in blood smears and (2) via TEM for the number of virions within erythrocytes. The mean prevalence of intracytoplasmic IBs in the blood cells increased from 0% at 0–4 d postexposure to 94% at 28 d postexposure. Viral load within circulating red blood cells peaked at 7 d postexposure, fell slightly, and then reached a plateau. However, blood cells observed within the kidney and spleen tissues demonstrated high levels of ENV between 14 and 28 d postexposure. The results indicate that the viral load within erythrocytes does not correlate well with IB prevalence and that the virus can persist in infected fish for more than 28 d.
Kehrmann, Jan; Chapot, Valerie; Buer, Jan; Rating, Philipp; Bornfeld, Norbert; Steinmann, Joerg
2018-05-01
The purpose of this investigation was to evaluate the performance of blood culture bottles in comparison to conventional microbiological culture techniques in detecting causative microorganisms of endophthalmitis and to determine their anti-infective susceptibility profiles. All consecutive cases with clinically suspected endophthalmitis in a university-based ophthalmology department between January 2009 and December 2016 were analysed in this retrospective comparative case series. Samples from 247 patients with suspected endophthalmitis underwent microbiological diagnostic work-up. All three culture methods were performed from 140 vitreous specimens. Vitreous fluid specimens were inoculated in blood culture bottles, aerobic and anaerobic broth solutions, and on solid media. Anti-infective susceptibility profiles were evaluated by semi-automated methods and/or gradient diffusion methods. Microorganisms were grown in 82 of 140 specimens for which all methods were performed (59%). Microorganisms were more frequently grown from blood culture bottles (55%) compared to broth solution (45%, p = 0.007) and solid media (33%, p < 0.0001). Considerable differences in the performance among culture media were detected for fungal pathogens. All grown fungi were detected by blood culture bottles (11 of 11, 100%). Broth solution recovered 64% and solid media 46% of grown fungi. No Gram-positive bacterium was resistant to vancomycin and all Gram-negative pathogens except for one isolate were susceptible to third-generation cephalosporins. In suspected endophthalmitis patients, blood culture bottles have a higher overall pathogen detection rate from vitreous fluid compared to conventional microbiological media, especially for fungi. The initial intravitreal antibiotic therapy with vancomycin plus third-generation cephalosporins appears to be an appropriate treatment approach for bacterial endophthalmitis.
Microbial contamination of the Tzu-Chi Cord Blood Bank from 2005 to 2006.
Chen, Shu-Huey; Zheng, Ya-Jun; Yang, Shang-Hsien; Yang, Kuo-Liang; Shyr, Ming-Hwang; Ho, Yu-Huai
2008-01-01
In total, 4502 units of cord blood (CB) were collected during a 2-year period from 2005 to 2006 by the Buddhist Tzu-Chi Stem Cells Center. The aim of this study was to analyze the incidence of microbial contamination and type of organism present in the cord blood. The clinical impact of microbial contamination on hematopoietic progenitor cell (HPC) grafts used for HPC transplantation is also discussed. First and second specimens were obtained for microbial assessment. These were collected in laboratory after cord blood collection and after cord blood unit manipulation, respectively. The samples were cultured and the results reviewed. The overall incidence of microbiological contamination was 1.8% (82/4502). Three CB units were contaminated with two different organisms. Infectious organisms comprised 9.4% (8/85) of total isolated microbes. These infectious microorganisms were beta-Streptococci group B, Candida tropicalis and Staphylococcus aureus which were isolated in 6, 1 and 1 of CB units respectively. Escherichia coli, Bacteroides fragilis, Lactobacillus spp., Enterococcus, beta-Streptococcus Group B, Bacteroides valgatus, Corynebacterium spp., Klebsiella pneumonia and Peptococcus spp. were the most frequently encountered microorganisms. A higher contamination rate of the CB units was noted after vaginal delivery (2.16%) compared to caesarian section (0.85%) (p < 0.01). Extensive training in CB collection, good procedures and good protocols can decrease the rate of microbial contamination. The use of a closed collecting system and an ex utero method have the advantage of a lower contamination rate. In our cord blood bank, we use a closed system but an in utero method. Similar to other studies, most of microorganisms reported here as contaminants are non-pathogenic.
The blood donation experience: self-reported motives and obstacles for donating blood.
Sojka, B Nilsson; Sojka, P
2008-01-01
The aim of the study was to investigate motives for donating blood as well as difficulties and obstacles associated with blood donation as perceived by the donors themselves. Six hundred consecutive blood donors (i.e. all blood donors with a history of at least one previous whole blood donation attending, during nine working days, the Blood Centre of Umeå University Hospital) received a self-administered questionnaire that contained questions aimed at elucidating motives for donating blood (general motives for donating blood, specific motives for the first donation and motives for continuing to be an active blood donor). Questions concerning difficulties and obstacles that had to be overcome in order to continue being a blood donor were also included in the questionnaire. Altogether 531 whole blood donors filled in the questionnaire (88.5%; 322 men and 209 women). No statistically significant differences were found between male and female blood donors concerning general reasons and motives related to donating blood. The most frequently reported reasons for giving blood the first time were 'influence from a friend' (47.2% of donors) and 'request via media' (23.5% of donors). Among general reasons/motives with highest ranking of importance, the most commonly reported motive for donating blood were 'general altruism' (40.3%), 'social responsibility/obligation' (19.7%) and 'influence from friends' (17.9%). General altruism' and 'social responsibility/obligation' were also the most frequent reasons for continuing to donate blood (68.4 and 16.0%, respectively). The most commonly reported obstacle to becoming a regular blood donor was 'laziness' (19.1%) followed by 'fear of needles' (10.5%). Altruism was the most common general motive for donating blood and also for continuing to be an active blood donor. Yet, for the first blood donation, direct 'influence from friends/relatives', 'media appeal' and other types of recruitment were more commonly reported as reasons or motives for donating blood than altruism. The findings support the notion that different strategies should be used/adopted to get people to donate blood the first time (e.g. recruitment through other blood donors using, for example, the 'bring a friend along' method) and to retain these subjects as active blood donors (e.g. by information and by strengthening their sense of being a blood donor or their self-efficacy etc.).
Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros
Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N.; Payne, Junaidi
2013-01-01
Objective To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. Results BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. Conclusions This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases. PMID:23593586
Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D
2012-02-01
The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.
Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter
2014-01-01
Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941
Machado, Patrícia; Manco, Licínio; Gomes, Cláudia; Mendes, Cristina; Fernandes, Natércia; Salomé, Graça; Sitoe, Luis; Chibute, Sérgio; Langa, José; Ribeiro, Letícia; Miranda, Juliana; Cano, Jorge; Pinto, João; Amorim, António; do Rosário, Virgílio E.; Arez, Ana Paula
2012-01-01
Background Pyruvate kinase (PK) deficiency, causing hemolytic anemia, has been associated to malaria protection and its prevalence in sub-Saharan Africa is not known so far. This work shows the results of a study undertaken to determine PK deficiency occurrence in some sub-Saharan African countries, as well as finding a prevalent PK variant underlying this deficiency. Materials and Methods Blood samples of individuals from four malaria endemic countries (Mozambique, Angola, Equatorial Guinea and Sao Tome and Principe) were analyzed in order to determine PK deficiency occurrence and detect any possible high frequent PK variant mutation. The association between this mutation and malaria was ascertained through association studies involving sample groups from individuals showing different malaria infection and outcome status. Results The percentage of individuals showing a reduced PK activity in Maputo was 4.1% and the missense mutation G829A (Glu277Lys) in the PKLR gene (only identified in three individuals worldwide to date) was identified in a high frequency. Heterozygous carrier frequency was between 6.7% and 2.6%. A significant association was not detected between either PK reduced activity or allele 829A frequency and malaria infection and outcome, although the variant was more frequent among individuals with uncomplicated malaria. Conclusions This was the first study on the occurrence of PK deficiency in several areas of Africa. A common PKLR mutation G829A (Glu277Lys) was identified. A global geographical co-distribution between malaria and high frequency of PK deficiency seems to occur suggesting that malaria may be a selective force raising the frequency of this 277Lys variant. PMID:23082140
Infrared Spectroscopy of Blood for Disease Identification
NASA Astrophysics Data System (ADS)
Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.
2003-09-01
Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.
Edmunds, L M; Rawlinson, A
1998-10-01
Blood contamination of 16 surfaces in the dental surgery was investigated using the Kastle-Meyer test for haemoglobin, after three types of periodontal procedures had been performed on a total of 30 patients. The effect of cleaning surfaces contaminated by blood was investigated using the same test. Cleaning materials used in the dental surgery were tested to rule out the possibility of false positive outcomes and the sensitivity of the test was determined prior to the study. The results show a marked variation in the degree of contamination and efficacy of cleaning following treatment. Overall, root planing was associated with the most widespread and frequent blood contamination and gingival surgery the least. The surgery work surface, edge of the spittoon, aspirator tube and ultrasonic scaler handpiece into which the ultrasonic insert fits, were the most frequently contaminated surfaces. The work surface, dentist's pen, light switch and handle were cleaned most effectively. The least effectively cleaned surfaces were the water dispenser switch, aspirator tube, bracket table and ultrasonic scaler handpiece. Methods for reducing this potential source of cross-infection are discussed.
Wang, Hongdan; Kang, Bing; Gao, Yue; Huo, Xiaodong; Li, Tao; Guo, Qiannan; Zhu, Bofeng; Liao, Shixiu
2017-04-10
To study the genetic polymorphisms and mutations of 20 frequently used autosomal microsatellites among ethnic Hans from Henan. Peripheral blood samples of 2604 individuals were collected. DNA was amplified and genotyped using a PowerPlex(TM) 21 system. The frequencies, forensic parameters and mutation rates of the 20 short tandem repeat (STR) loci were analyzed. A total of 323 alleles were found in this population and the allelic frequencies have ranged from 0.0003 to 0.5144. Except for D3S1358, TH01 and TPOX, mutations have been found in all of the remaining 17 STR loci, which totaled 47, with mutation rates ranging from 0 to 3.46 × 10 -3 . The 20 STR loci selected by the PowerPlex(TM) 21 system are highly polymorphic among ethnic Hans from Henan, and may be of great value in forensic and human population studies. As no similar study has been carried out previously, above results may be of great value for individual discrimination and paternal testing.
Prevalence of vitamin D deficiency and insufficiency among adult asthmatic patients in Karachi.
Kamran, Afshan; Alam, Syed Mahboob; Qadir, Farida
2014-11-01
Vitamin D deficiency has assumed pandemic proportions all over the world. It has been documented as a frequent problem in studies of young adults, elderly person and children in other countries, but there is no reliable data on vitamin D status of adult asthmatic patients in Pakistan. To determine the prevalence of vitamin D deficiency and insufficiency in adult asthmatic patients with moderate to severe asthma using a cross-sectional study design in Basic Medical Sciences Institute, Jinnah Postgraduate Medical Centre, Karachi.311 adult asthmatic patients with moderate to severe asthma were recruited from JPMC, tertiary care hospital in Karachi. Questionnaires were administered together demographics, height, weight, nutritional and physical activity assessment. Blood samples for vitamin D measurement were also taken. Results show high prevalence of vitamin D deficiency and insufficiency (88.10%) in adult patients with moderate to severe persistent asthma. Vitamin D deficiency and insufficiency was more frequently observed in female than in male patients.67.66% of the female patients had serum vitamin D level less than 20 ng/ml as compare to 56.1% of the male patients (p=0.01).
Energy demands in competitive soccer.
Bangsbo, J
1994-01-01
In elite outfield players, the average work rate during a soccer match, as estimated from variables such as heart rate, is approximately 70% of maximal oxygen uptake (VO2 max). This corresponds to an energy production of approximately 5700 kJ (1360 kcal) for a person weighing 75 kg with a VO2 max of 60 ml kg-1 min-1. Aerobic energy production appears to account for more than 90% of total energy consumption. Nevertheless, anaerobic energy production plays an essential role during soccer matches. During intensive exercise periods of a game, creatine phosphate, and to a lesser extent the stored adenosine triphosphate, are utilized. Both compounds are partly restored during a subsequent prolonged rest period. In blood samples taken after top-class soccer matches, the lactate concentration averages 3-9 mM, and individual values frequently exceed 10 mM during match-play. Furthermore, the adenosine diphosphate degradation products--ammonia/ammonium, hypoxanthine and uric acid--are elevated in the blood during soccer matches. Thus, the anaerobic energy systems are heavily taxes during periods of match-play. Glycogen in the working muscle seems to be the most important substrate for energy production during soccer matches. However, muscle triglycerides, blood free fatty acids and glucose are also used as substrates for oxidative metabolism in the muscles.
Sakalauskiene, Jurgina; Kubilius, Ricardas; Gleiznys, Alvydas; Vitkauskiene, Astra; Ivanauskiene, Egle; Šaferis, Viktoras
2014-10-08
The aim of the study was to analyze how metabolic control of type 1 diabetes is related to clinical and microbiological periodontal parameters. The study involved 56 subjects aged from 19 to 50 years divided into 2 groups: healthy subjects (the H group), and diabetic (type 1 diabetes) patients with chronic untreated generalized periodontitis (the DM group). The glycosylated hemoglobin value (HbA1c) was determined using the UniCel DxC 800 SYNCHRON System (Beckman Coulter, USA), and the concentration in blood was measured by the turbidimetric immunoinhibition method. A molecular genetic assay (Micro-IDent plus, Germany) was used to detect periodontopathogenic bacteria in plaque samples. Periodontitis was confirmed by clinical and radiological examination. Fusobacterium nucleatum, Capnocytophaga species, and Eikenella corrodens were the most frequently found bacteria in dental plaque samples (77.8%, 66.7%, and 33.4%, respectively), whereas Aggregatibacter actinomycetemcomitans was identified 40.7% less frequently in the DM group than in the H group. The strongest relationship was observed between the presence of 2 periodontal pathogens - F. nucleatum and Capnocytophaga spp. - and poorer metabolic control in type 1 diabetes patients (HbA1c) and all clinical parameters of periodontal pathology. Periodontal disease was more evident in type 1 diabetic patients, and the prevalence of periodontitis was greatly increased in subjects with poorer metabolic control.
Depression in sickle cell disease.
Hasan, Syed Parwez; Hashmi, Shahzad; Alhassen, Mohammed; Lawson, William; Castro, Oswaldo
2003-01-01
PURPOSE: To assess the prevalence of depressive symptoms and examine the contribution of demographics, disease severity, and health care use variables to depressive symptoms in sickle cell patients who had been in stable health for at least one month. PATIENTS AND METHODS: Subjects were a convenience sample of 27 men and 23 women selected during a routine visit to the sickle cell clinic at Howard University Hospital. Depression was assessed using a cut-off score from the Beck Depression Inventory (BDI) and related to a variety of health outcomes. RESULTS: The results of the analyses indicate that 44% (n=22) of the sample scored within the mild to severe (>20) range of depression on the BDI. Depressed sickle cell patients were more frequently treated in emergency rooms and more likely to be hospitalized with vaso-occlusive crises. Patients more likely to be depressed were: those with low family income (<$10,000); less than high school education; female; those who had multiple blood transfusions; poor pain control; inadequate social support; hydroxyurea use; and had histories of frequent vaso-occlusive crises. CONCLUSION: The prevalence of depressive symptoms in sickle cell patients is high compared to the general African American population. Our findings confirmed previous studies examining the occurrence of depression in adults with sickle cell disease. Treatment of depression should be strongly considered to improve the quality of life and probably disease course in sickle cell patients. PMID:12911250
NHEXAS PHASE I MARYLAND STUDY--LIPIDS IN BLOOD ANALYTICAL RESULTS
The Lipids in Blood data set presents concentrations of cholesterol and total triglycerides in blood serum. The data set presents measurements for up to 2 lipids in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent w...
Deshpande, Abhishek; Cadnum, Jennifer L; Fertelli, Dennis; Sitzlar, Brett; Thota, Priyaleela; Mana, Thriveen S; Jencson, Annette; Alhmidi, Heba; Koganti, Sreelatha; Donskey, Curtis J
2017-03-01
In a survey of 5 hospitals, we found that floors in patient rooms were frequently contaminated with pathogens and high-touch objects such as blood pressure cuffs and call buttons were often in contact with the floor. Contact with objects on floors frequently resulted in transfer of pathogens to hands. Published by Elsevier Inc.
McDonell, Michael G.; Skalisky, Jordan; Leickly, Emily; Orr, Michael F.; Roll, John; McPherson, Sterling; Hill-Kapturczak, Nathalie; Javors, Martin
2018-01-01
Phosphatidylethanol (PEth) can be detected in blood from 14 to as many as 28 days after alcohol consumption, depending on the amount and frequency of alcohol consumed. PEth may have utility for verifying abstinence in a contingency management (CM) intervention for alcohol use, particularly in settings where frequent verification of abstinence is impossible or impractical. Five nontreatment-seeking heavy drinkers (40% men) participated in an 11-week, ABA-phased within-subject experiment for which they submitted blood spots for PEth measurement, urine samples for ethyl glucuronide (EtG) testing, and self-report drinking data weekly. Participants received reinforcers for submitting samples throughout the A phases. During the B phase (CM phase), they received additional reinforcers when their PEth level was reduced from the previous week and was verified by a negative EtG (<150 ng/ml) urine test and self-report. PEth, EtG, and self-report outcomes were compared between A phases (Weeks 1–3, 8–11) and B phases (Weeks 4–7). During the A phases, 23% of PEth results indicated alcohol abstinence, whereas 53% of PEth samples submitted during the CM (B phase) indicated alcohol abstinence. Participants were more likely to submit EtG-negative urine samples and report lower levels of drinking and heavy drinking during the B phase, relative to the A phases. We also explored the ability of PEth to detect self-reported drinking. The combined PEth homologs (16:0/18:1 and 16:0/18:2) predicted self-reported drinking with area under the curve from 0.81 (1 week) to 0.80 (3 weeks). Results support the initial feasibility of a Peth-based CM intervention. PMID:28714726
Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar
2013-10-01
Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.
Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L
2007-01-01
Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958
Azzouz, Abdelmonaim; Rascón, Andrés J; Ballesteros, Evaristo
2016-06-01
Humans are exposed to hazardous substances including endocrine-disrupting chemicals (EDCs). These compounds have been associated with some diseases such as cancer and ascribed adverse effects on life-essential organs. The method, which allows the determination of both free and conjugated forms of EDCs, involves the liquid-liquid extraction from the sample with ethyl acetate, followed by its preconcentration and clean-up by SPE in a continuous system for the subsequent determination by GC-MS. The proposed method affords very low LODs and RSD. This allowed its successful application to the determination of EDCs in human urine, blood and breast milk. The most frequently founded were methylparaben, ethylparaben, bisphenol A and triclosan.
Patient identification in blood sampling.
Davidson, Anne; Bolton-Maggs, Paula
The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.
Moustafa, Mohamed Abdallah Mohamed; Shimozuru, Michito; Mohamed, Wessam; Taylor, Kyle Rueben; Nakao, Ryo; Sashika, Mariko; Tsubota, Toshio
2017-08-01
Sarcocystis and Hepatozoon species are protozoan parasites that are frequently detected in domestic and wild animals. Rodents are considered common intermediate and paratenic hosts for several Sarcocystis and Hepatozoon species. Here, blood DNA samples from a total of six rodents, including one Myodes rutilus, one Myodes rufocanus, and four Apodemus speciosus, collected from Hokkaido, Japan, were shown by conventional PCR of the 18S ribosomal RNA (rRNA) gene to contain Sarcocystis and Hepatozoon DNA. Sequencing of the DNA detected one Sarcocystis sp. in the M. rufocanus sample and two different Hepatozoon spp. in the M. rutilus and A. speciosus samples. Phylogenetic analysis showed that the detected Sarcocystis sp. sequence grouped with GenBank Sarcocystis sequences from rodents, snakes, and raccoons from Japan and China. The 18S rRNA partial gene sequences of both detected Hepatozoon spp. clustered with GenBank Hepatozoon sequences from snakes, geckos and voles in Europe, Africa, and Asia. This study provides evidence that wild rodents have a role in the maintenance of Sarcocystis and Hepatozoon species on the island of Hokkaido.
Impact of Parvovirus B19 Viremia in Liver Transplanted Children on Anemia: A Retrospective Study.
Würdinger, Michael; Modrow, Susanne; Plentz, Annelie
2017-06-13
Acute parvovirus B19 (B19V) infection in immunocompromised patients may lead to severe anemia. However, in adult transplant recipients, B19V reactivations without anemia and low-level viremia are common. The impact of B19V in pediatric transplant patients, with high risk of primary infection, is investigated here. In a six-month period, 159 blood samples of 54 pediatric liver transplant recipients were tested for B19V DNA by quantitative real-time PCR. Viremia was correlated with anemia and immunosuppression and compared with rates in adult transplant recipients. B19V DNA was detected in 5/54 patients. Primary B19V infections were observed in four patients prior to and in one patient after transplantation. Rates of viremia were significantly higher in pediatric recipients than in adults. Prolonged virus shedding after primary infection prior to transplantation accounts for most viremic cases. Anemia was significantly more frequent in samples from viremic patients, but remained mild. In 15% of anemic samples, B19V DNA was detected. Therefore, in anemic pediatric transplant recipients, diagnostics for B19V seem reasonable.
Tierney, Rosemary J; Edwards, Rachel Hood; Sitki-Green, Diane; Croom-Carter, Deborah; Roy, Sushmita; Yao, Qing-Yun; Raab-Traub, Nancy; Rickinson, Alan B
2006-01-15
Recent work using a heteroduplex tracking assay (HTA) to identify resident viral sequences has suggested that patients with infectious mononucleosis (IM) who are undergoing primary Epstein-Barr virus (EBV) infection frequently harbor different EBV strains. Here, we examine samples from patients with IM by use of a new Epstein-Barr nuclear antigen 2 HTA alongside the established latent membrane protein 1 HTA. Coresident allelic sequences were detected in ex vivo blood and throat wash samples from 13 of 14 patients with IM; most patients carried 2 or more type 1 strains, 1 patient carried 2 type 2 strains, and 1 patient carried both virus types. In contrast, coresident strains were detected in only 2 of 14 patients by in vitro B cell transformation, despite screening >20 isolates/patient. We infer that coacquisition of multiple strains is common in patients with IM, although only 1 strain tends to be rescued in vitro; whether nonrescued strains are present in low abundance or are transformation defective remains to be determined.
Rebound hyperglycaemia in diabetic cats.
Roomp, Kirsten; Rand, Jacquie
2016-08-01
Rebound hyperglycaemia (also termed Somogyi effect) is defined as hyperglycaemia caused by the release of counter-regulatory hormones in response to insulin-induced hypoglycaemia, and is widely believed to be common in diabetic cats. However, studies in human diabetic patients over the past quarter century have rejected the common occurrence of this phenomenon. Therefore, we evaluated the occurrence and prevalence of rebound hyperglycaemia in diabetic cats. In a retrospective study, 10,767 blood glucose curves of 55 cats treated with glargine using an intensive blood glucose regulation protocol with a median of five blood glucose measurements per day were evaluated for evidence of rebound hyperglycaemic events, defined in two different ways (with and without an insulin resistance component). While biochemical hypoglycaemia occurred frequently, blood glucose curves consistent with rebound hyperglycaemia with insulin resistance was confined to four single events in four different cats. In 14/55 cats (25%), a median of 1.5% (range 0.32-7.7%) of blood glucose curves were consistent with rebound hyperglycaemia without an insulin resistance component; this represented 0.42% of blood glucose curves in both affected and unaffected cats. We conclude that despite the frequent occurrence of biochemical hypoglycaemia, rebound hyperglycaemia is rare in cats treated with glargine on a protocol aimed at tight glycaemic control. For glargine-treated cats, insulin dose should not be reduced when there is hyperglycaemia in the absence of biochemical or clinical evidence of hypoglycaemia. © ISFM and AAFP 2015.
Voorn, Veronique M A; Marang-van de Mheen, Perla J; Wentink, Manon M; Kaptein, Ad A; Koopman-van Gemert, Ankie W M M; So-Osman, Cynthia; Vliet Vlieland, Thea P M; Nelissen, Rob G H H; van Bodegom-Vos, Leti
2014-10-01
Despite evidence that the blood-saving measures (BSMs) erythropoietin (EPO) and intra- and postoperative blood salvage are not (cost-)effective in primary elective total hip and knee arthroplasties, they are used frequently in Dutch hospitals. This study aims to assess the impact of barriers associated with the intention of physicians to stop BSMs. A survey among 400 orthopedic surgeons and 400 anesthesiologists within the Netherlands was performed. Multivariate logistic regression was used to identify barriers associated with intention to stop BSMs. A total of 153 (40%) orthopedic surgeons and 100 (27%) anesthesiologists responded. Of all responders 67% used EPO, perioperative blood salvage, or a combination. After reading the evidence on non-cost-effective BSMs, 50% of respondents intended to stop EPO and 53% to stop perioperative blood salvage. In general, barriers perceived most frequently were lack of attention for blood management (90% of respondents), department priority to prevent transfusions (88%), and patient characteristics such as comorbidity (81%). Barriers significantly associated with intention to stop EPO were lack of interest to save money and the impact of other involved parties. Barriers significantly associated with intention to stop perioperative blood salvage were concerns about patient safety, lack of alternatives, losing experience with the technique, and lack of interest to save money. Physicians experience barriers to stop using BSMs, related to their own technical skills, patient safety, current blood management policy, and lack of interest to save money. These barriers should be targeted in strategies to make BSM use cost-effective. © 2014 AABB.
[Hypothermia as the cause of death in forensic pathology: autopsy study].
Nikolić, Slobodan; Zivković, Magdalena; Zivković, Vladimir; Juković, Fehim
2010-01-01
The body cooling process goes through few clinical phases. These are followed by some morphological thanatological changes such as frost erythema and Wischnewsky's spots, which are used in diagnosis of death due to hypothermia. In such cases there is no any specific autopsy finding. To establish the frequency of hypothermia as the cause of death for a ten-year-period, and to analyze the sample according to gender and age, risk factors and autopsy findings of subjects. A retrospective autopsy study was performed for a ten-year-period (total of 12,765 forensic autopsies). The relevant data were collected from autopsy records, police reports and heteroanamnestic interviews. The sample was analyzed according to gender, age, scene of death, blood alcohol concentration, risk factors, and autopsy findings of all observed subjects. The sample included 67 subjects, 42 males and 25 females (chi2 = 4.31; p < 0.05), of average age 63.9 +/- 14.7 years (min=27, max=92; med=65, mod=55). Nineteen of subjects were found at in-door places. In 13 subjects blood alcohol concentration ranged from 0.50 to 3.32 promille (average 1.81 +/- 0.93). The younger the observed subject was, the higher the blood alcohol concentration (p = -0.251; p = 0.04). One third of the observed subjects were chronic alcohol abusers. Thirteen persons had psychiatric diseases. In 43 observed subjects the concomitant appearance of frost erythema and Wischniewsky's spots were established (chi2 = 49.59; df = 3; p < 0.001). In the analyzed ten-year period hypothermia was not often the cause of death; it was disclosed only in 0.5% of the total number of the studied autopsies. The most of the deceased were older males with cardiovascular problems found in unprotected open-air places. The most frequent thanatological findings in the analyzed subjects were frost erythema and Wischnewsky's spots.
Monitoring for bovine arboviruses in the most southwestern islands in Japan between 1994 and 2014.
Kato, Tomoko; Yanase, Tohru; Suzuki, Moemi; Katagiri, Yoshito; Ikemiyagi, Kazufumi; Takayoshi, Katsunori; Shirafuji, Hiroaki; Ohashi, Seiichi; Yoshida, Kazuo; Yamakawa, Makoto; Tsuda, Tomoyuki
2016-06-24
In Japan, epizootic arboviral infections have severely impacted the livestock industry for a long period. Akabane, Aino, Chuzan, bovine ephemeral fever and Ibaraki viruses have repeatedly caused epizootic abnormal births and febrile illness in the cattle population. In addition, Peaton, Sathuperi, Shamonda and D'Aguilar viruses and epizootic hemorrhagic virus serotype 7 have recently emerged in Japan and are also considered to be involved in abnormal births in cattle. The above-mentioned viruses are hypothesized to circulate in tropical and subtropical Asia year round and to be introduced to temperate East Asia by long-distance aerial dispersal of infected vectors. To watch for arbovirus incursion and assess the possibility of its early warning, monitoring for arboviruses was conducted in the Yaeyama Islands, located at the most southwestern area of Japan, between 1994 and 2014. Blood sampling was conducted once a year, in the autumn, in 40 to 60 healthy cattle from the Yaeyama Islands. Blood samples were tested for arboviruses. A total of 33 arboviruses including Akabane, Peaton, Chuzan, D' Aguilar, Bunyip Creek, Batai and epizootic hemorrhagic viruses were isolated from bovine blood samples. Serological surveillance for the bovine arboviruses associated with cattle diseases in young cattle (ages 6-12 months: had only been alive for one summer) clearly showed their frequent incursion into the Yaeyama Islands. In some cases, the arbovirus incursions could be detected in the Yaeyama Islands prior to their spread to mainland Japan. We showed that long-term surveillance in the Yaeyama Islands could estimate the activity of bovine arboviruses in neighboring regions and may provide a useful early warning for likely arbovirus infections in Japan. The findings in this study could contribute to the planning of prevention and control for bovine arbovirus infections in Japan and cooperative efforts among neighboring countries in East Asia.
Sampling and storage of blood for pH and blood gas analysis.
Haskins, S C
1977-02-15
Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.
Next-Generation Sequencing Reveals Frequent Opportunities for Exposure to Hepatitis C Virus in Ghana
Phillips, Richard O.; Mora, Nallely; Xia, Guo-liang; Campo, David S.; Purdy, Michael A.; Dimitrova, Zoya E.; Owusu, Dorcas O.; Punkova, Lili T.; Skums, Pavel; Owusu-Ofori, Shirley; Sarfo, Fred Stephen; Vaughan, Gilberto; Roh, Hajung; Opare-Sem, Ohene K.; Cooper, Richard S.; Khudyakov, Yury E.
2015-01-01
Globally, hepatitis C Virus (HCV) infection is responsible for a large proportion of persons with liver disease, including cancer. The infection is highly prevalent in sub-Saharan Africa. West Africa was identified as a geographic origin of two HCV genotypes. However, little is known about the genetic composition of HCV populations in many countries of the region. Using conventional and next-generation sequencing (NGS), we identified and genetically characterized 65 HCV strains circulating among HCV-positive blood donors in Kumasi, Ghana. Phylogenetic analysis using consensus sequences derived from 3 genomic regions of the HCV genome, 5'-untranslated region, hypervariable region 1 (HVR1) and NS5B gene, consistently classified the HCV variants (n = 65) into genotypes 1 (HCV-1, 15%) and genotype 2 (HCV-2, 85%). The Ghanaian and West African HCV-2 NS5B sequences were found completely intermixed in the phylogenetic tree, indicating a substantial genetic heterogeneity of HCV-2 in Ghana. Analysis of HVR1 sequences from intra-host HCV variants obtained by NGS showed that three donors were infected with >1 HCV strain, including infections with 2 genotypes. Two other donors share an HCV strain, indicating HCV transmission between them. The HCV-2 strain sampled from one donor was replaced with another HCV-2 strain after only 2 months of observation, indicating rapid strain switching. Bayesian analysis estimated that the HCV-2 strains in Ghana were expanding since the 16th century. The blood donors in Kumasi, Ghana, are infected with a very heterogeneous HCV population of HCV-1 and HCV-2, with HCV-2 being prevalent. The detection of three cases of co- or super-infections and transmission linkage between 2 cases suggests frequent opportunities for HCV exposure among the blood donors and is consistent with the reported high HCV prevalence. The conditions for effective HCV-2 transmission existed for ~ 3–4 centuries, indicating a long epidemic history of HCV-2 in Ghana. PMID:26683463
Siafakas, Nikolaos; Attilakos, Ahilleas; Vourli, Sofia; Stefos, Efstathios; Meletiadis, Joseph; Nikolaidou, Polyxeni; Zerva, Loukia
2011-01-01
Although enteroviral infections occur frequently during childhood, the circulation of particular serotypes has never been studied in Greece. The objectives of the present report were molecular detection and identification of human enteroviruses in children admitted with nonspecific febrile illness or meningitis to a university hospital during a 22-month period. A one-step Real-Time RT-PCR protocol was used for rapid enterovirus detection in genetic material extracted directly from clinical samples, and a sensitive reverse transcription-semi-nested PCR targeting part of the VP1-coding region was used for genotypic identification of the different serotypes. Twenty-one enterovirus strains were detected and identified in 20 stool samples, one cerebrospinal fluid (CSF) sample, one whole blood sample and one throat swab from 21 out of 134 febrile patients (15.7%). Ten strains belonged to Human Enterovirus Species B (HEV-B) (six serotypes) and eleven to HEV-A (four serotypes). Most of the strains were closely associated with virulent strains circulating in Europe and elsewhere. Detection of the emerging pathogen enterovirus 71 for a first time in Greece was particularly important. Copyright © 2011 Elsevier Ltd. All rights reserved.
Burrowing Owls, Pulex irritans, and Plague.
Belthoff, James R; Bernhardt, Scott A; Ball, Christopher L; Gregg, Michael; Johnson, David H; Ketterling, Rachel; Price, Emily; Tinker, Juliette K
2015-09-01
Western Burrowing Owls (Athene cunicularia hypugaea) are small, ground-dwelling owls of western North America that frequent prairie dog (Cynomys spp.) towns and other grasslands. Because they rely on rodent prey and occupy burrows once or concurrently inhabited by fossorial mammals, the owls often harbor fleas. We examined the potential role of fleas found on burrowing owls in plague dynamics by evaluating prevalence of Yersinia pestis in fleas collected from burrowing owls and in owl blood. During 2012-2013, fleas and blood were collected from burrowing owls in portions of five states with endemic plague-Idaho, Oregon, Washington, Colorado, and South Dakota. Fleas were enumerated, taxonomically identified, pooled by nest, and assayed for Y. pestis using culturing and molecular (PCR) approaches. Owl blood underwent serological analysis for plague antibodies and nested PCR for detection of Y. pestis. Of more than 4750 fleas collected from owls, Pulex irritans, a known plague vector in portions of its range, comprised more than 99.4%. However, diagnostic tests for Y. pestis of flea pools (culturing and PCR) and owl blood (PCR and serology) were negative. Thus, even though fleas were prevalent on burrowing owls and the potential for a relationship with burrowing owls as a phoretic host of infected fleas exists, we found no evidence of Y. pestis in sampled fleas or in owls that harbored them. We suggest that studies similar to those reported here during plague epizootics will be especially useful for confirming these results.
Oliveira, A T; Araújo, M L G; Pantoja-Lima, J; Aride, P H R; Tavares-Dias, M; Brinn, R P; Marcon, J L
2017-01-01
Intraerythrocytic parasites are frequently found in fish, including elasmobranchs. The Amazonian rivers present well defined annual hydrological cycles that results in drastic modifications of the environmental conditions with deep implications in the life cycle of the whole associated biota in those fluvial systems. The freshwater stingray Potamotrygon wallacei (stingray cururu) is a new species restricted to the Middle Rio Negro basin and it is subject to strong alterations in their natural habitats (igapós) a result of the constant variations in the water level of Rio Negro. This work demonstrates the occurrence of intraerythrocytic parasite Cyrilia sp. in this stingray species. Additionally, the prevalence and quantification of hemoparasites in different phases of Rio Negro were also established. Field sampling was carried in the Archipelago of Mariuá, Middle Rio Negro, involving different stages of the water cycle. The intraerythrocytic parasites were quantified by direct counting in blood smears using a total counting of 2000 erythrocytes in each blood smear. The presence of parasites intraerythrocytic generates changes in the morphology of blood cell. The largest amount of the hemoparasites was recorded in the drought period. We observed a decreasing tendency in the number of parasites in the blood between the drought periods and inundation. We concluded that the level of Negro River influences the incidence of intraerythrocytic parasites in the cururu stingray and the drought represents the period of larger susceptibility to the infestation.
Method of high-precision microsampled blood and plasma mass densitometry
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.
Uettwiller, Florence; Chemin, Aude; Bonnemaison, Elisabeth; Favrais, Géraldine; Saliba, Elie; Labarthe, François
2015-01-01
Objectives Hypoglycemia is frequent in very low birth weight (VLBW) neonates and compromises their neurological outcome. The aim of this study was to compare real-time continuous glucose monitoring system (RT-CGMS) to standard methods by intermittent capillary blood glucose testing in detecting and managing hypoglycemia. Study design Forty-eight VLBW neonates were enrolled in this prospective study. During their 3 first days of life, their glucose level was monitored either by RT-CGMS (CGM-group), or by intermittent capillary glucose testing (IGM-group) associated with a blind-CGMS to detect retrospectively missed hypoglycemia. Outcomes were the number and duration of hypoglycemic (≤50mg/dl) episodes per patient detected by CGMS. Results Forty-three monitorings were analyzed (IGM n = 21, CGM n = 22), with a median recording time of 72 hours. In the IGM group, blind-CGMS revealed a significantly higher number of hypoglycemia episodes than capillary blood glucose testing (1.2±0.4 vs 0.4±0.2 episode/patient, p<0.01). In the CGM-group, the use of RT-CGMS made it possible (i) to detect the same number of hypoglycemia episodes as blind-CGMS (1.2±0.4 episode/patient), (ii) to adapt the glucose supply in neonates with hypoglycemia (increased supply during days 1 and 2), and (iii) to significantly reduce the duration of hypoglycemia episodes per patient (CGM 44[10–140] min versus IGM 95[15–520] min, p<0.05). Furthermore, it reduced the number of blood samples (CGM 16.9±1.0 vs IGM 21.9±1.0 blood sample/patient, p<0.001). Conclusion RT-CGMS played a beneficial role in managing hypoglycemia in VLBW neonates by adjusting the carbohydrate supply to the individual needs and by reducing the duration of hypoglycemia episodes. The clinical significance of the biological differences observed in our study need to be explored. PMID:25590334
A technique for extracting blood samples from mice in fire toxicity tests
NASA Technical Reports Server (NTRS)
Bucci, T. J.; Hilado, C. J.; Lopez, M. T.
1976-01-01
The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.
Rutten, Niels; Gonzales, José L.; Elbers, Armin R. W.; Velthuis, Annet G. J.
2012-01-01
Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. Methodology/Principal Findings The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood), sampling location (farm or packing station) and location of sample preparation (laboratory or packing station). It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393) a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. Conclusions/Significance This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards. PMID:22523543
NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN BLOOD ANALYTICAL RESULTS
The Pesticides in Blood Serum data set contains analytical results for measurements of up to 17 pesticides in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were ge...
Mann, S; Yepes, F A Leal; Behling-Kelly, E; McArt, J A A
2017-08-01
Despite increased efforts in preventing the occurrence of metabolic disorders in transition cows, hyperketonemia remains a frequent early-lactation metabolic disease affecting an average of 40% of cows in herds in the United States. Despite the demonstrated economic effect of this disorder, controlled clinical trials comparing different treatment strategies in affected cows are lacking. The objective of our study was to investigate the effect of treatment with intravenous glucose, oral propylene glycol, or a combination of both on the reduction in blood β-hydroxybutyrate (BHB) concentrations of early-lactation hyperketonemic dairy cows. Multiparous Holstein cows between 3 to 9 d in milk were screened for hyperketonemia using a handheld meter 3 times per week, and enrolled at whole blood BHB concentration ≥1.2 mmol/L to 1 of 4 treatment groups: (1) 500 mL of a 50% dextrose solution i.v. once daily for 3 d (GLU, n = 9), (2) 300 mL of propylene glycol as a drench once daily for 3 d (PG, n = 9), (3) a combination treatment of a 500 mL of 50% dextrose solution i.v. and 300 mL of propylene glycol orally once daily for 3 d (GLU+PG, n = 8), or (4) an untreated control group (CTRL, n = 8). Blood samples were collected immediately before as well as at 1, 2, 4, 8, 12, 24, 36, 48, 60, and 72 h after administration of the first treatment through a jugular catheter and 3 times per week thereafter from coccygeal vessels. Concentrations of BHB were measured in whole blood, and plasma samples were analyzed for glucose, fatty acid (NEFA), insulin, glucagon, and electrolyte concentrations. The EDTA-anticoagulated blood samples were assessed for red blood cell indices, and smears were made for evaluation of red blood cell morphology. Outcomes were analyzed using repeated measures analysis. Overall least squares means (95% CI) of whole blood BHB concentrations between 1 h and d 11 relative to first treatment were 1.11 (0.95 to 1.30), 1.26 (1.07 to 1.47), 0.96 (0.81 to 1.13), and 1.53 (1.30 to 1.80) mmol/L for the GLU, PG, GLU+PG, and CTRL groups, respectively. Treatment with both glucose and propylene glycol led to a greater magnitude and more prolonged decrease in BHB concentrations compared with individual treatments. The NEFA and glucagon concentrations were lower immediately after treatment in GLU and GLU+PG groups compared with CTRL, and treatment with both glucose and propylene glycol was associated with a greater increase in glucose and insulin concentrations immediately after treatment compared with CTRL and GLU treatment alone. Treatments did not lead to differences in plasma mineral concentrations. We conclude that treatments varied in the magnitude of decreasing blood BHB concentrations in hyperketonemic postpartum cows, with the greatest decline after treatment with a combination of intravenous glucose and oral propylene glycol. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Prados Madrona, Dalmiro; Fernández Herrera, María Dolores; Prados Jiménez, Dalmiro; Gómez Giraldo, Sonsoles; Robles Campos, Rita
2014-01-01
Women seem more willing to donate blood than men despite the limitations that affect their donation rate. The aim of our study was to determine the role of women in altruistic donation of blood in Huelva, a province in south-western Spain. We registered 87,601 offers to donate whole blood between January 1st, 2005 and December 31st, 2009. We statistically analysed variables such as sex, age, offers, deferrals and donations, problems in venous access, vasovagal reactions, weight and blood pressure to establish their significance according to donor gender. With regards to gender, 52.3% of donors were women and 47.7% men. Of the 87,601 offers to donate blood, 46.5% were from females and 53.5% from males. More females than males made their first donation during the study period. However, 43.9 % of donations were from women, whereas 56.1% were from men. Overall 8.7% of offers were deferred, 62.7% of which due to a low haemoglobin concentration, which was the most frequent cause of deferral in women. Difficulties in venous access and vasovagal reactions were also more frequent in female donors than in male donors. By the end of the study period, donor fidelity was 58.6% for men and 48.6% for women. In the province of Huelva, women are more altruistically inclined than men to give blood, with the percentages of donors and first-time donors being higher among females. However, there are restrictions to women giving blood, especially low haemoglobin concentration, which reduce the number of female blood donations. Women also have more difficulty when blood is withdrawn and are more susceptible to vasovagal reactions, which negatively affect their experience as donors. Measures should be taken to reduce these barriers to encourage women to continue to offer to donate blood, thereby ensuring that they become regular donors, which is a key factor in guaranteeing an adequate supply of blood within the region of Andalusia.
Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.
Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir
2012-06-01
According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT has a higher sensitivity and therefore may be preferred as a prescreening method in endemic or nonendemic areas.
The role of procalcitonin as a marker of diabetic foot ulcer infection.
Massara, Mafalda; De Caridi, Giovanni; Serra, Raffaele; Barillà, David; Cutrupi, Andrea; Volpe, Alberto; Cutrupi, Francesco; Alberti, Antonino; Volpe, Pietro
2017-02-01
Foot ulcers are frequent in diabetic patients and are responsible for 85% of amputations, especially in the presence of infection. The diagnosis of diabetic foot ulcer infection is essentially based on clinical evaluation, but laboratory parameters such as erythrocyte sedimentation rate (ESR), white blood count (WBC), C-reactive protein (CRP) and, more recently, procalcitonin (PCT) could aid the diagnosis, especially when clinical signs are misleading. Fifteen diabetic patients with infected foot ulcers were admitted to our department and were compared with an additional group of patients with non-infected diabetic foot ulcers (NIDFUs). Blood samples were collected from all patients in order to evaluate laboratory markers. In the current study, the diagnostic accuracy of PCT serum levels was evaluated in comparison with other inflammatory markers such as CRP, ESR and WBC as an indicator to make the distinction between infected diabetic foot ulcers (IDFUs) and NIDFUs. CRP, WBC, ESR and especially PCT measurements represent effective biomarkers in the diagnosis of foot infections in diabetic patients particularly when clinical signs are misleading. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Marcos, R; Pereira, C; Maia, J P; Santos, M; Luzzago, C; Lauzi, S; Genchi, C; Faustino, A; Puente-Payo, P
2017-01-01
The prevalence of canine Dirofilaria infection in Maio Island (Cape Verde) was analysed by serology, morphological and molecular identification of the parasite species. Blood and sera were collected from 150 dogs and 80 cats aged over 6 months from various localities of the island. DNA was extracted from blood and samples were screened by polymerase chain reaction (PCR) using microfilaria-specific primers. No Dirofilaria immitis was found in dogs while D. repens microfilariae were found in 5.3% of dogs and 6% were positive by PCR. The species identity was confirmed by sequencing of PCR products, which showed almost 100% homology with D. repens European sequences published in GenBank. No difference in Dirofilaria infection was observed between males and females or in dogs with different weights. However, older dogs and those from the western part of Maio Island were more frequently infected. No Dirofilaria was found in cats. This study represents the first evidence of D. repens in Cape Verde (West Africa) and highlights the need for implementing control measures and for a better surveillance of dirofilariosis in Africa.
Growth hormone suppression test
GH suppression test; Glucose loading test; Acromegaly - blood test; Gigantism - blood test ... At least 3 blood samples are taken. The test is done in the following way: The first blood sample is collected between 6 ...
[Participation of leucocytes in pathogenesis of primary forms of lower limb chronic venous disease].
Bogachev, V Iu; Golovanova, O V; Sergeeva, N A; Kuznetsov, A N
2011-01-01
The purpose of the study was to test the hypothesis on participation of WBCs in damaging the venous wall in patients presenting with primary forms of lower limb chronic venous diseases LLCVD . The study included a total of fifteen consecutively selected patients (13 women and 2 men) diagnosed as having grade C2-C-4 LLCVD according to the CEAP classification. Static loading (30 minutes in the sitting position) was followed by simultaneous sampling of blood from the varicose vein of the cms and ulnar vein. The total blood count including determination of both the absolute values and percentage of blood formed elements was performed using the automated haematological counter «Advia 7» («Bayer», USA). The obtained findings were statistically processed using the Microsoft Office Excel software by means of the pared two-sample τ-test for the average values. The number of leukocytes and their subpopulations in blood samples obtained from the crural varicose veins turned out to be significantly less as compared with that in blood sampled from the ulnar vein. Thus, blood sampled from the crural varicose veins demonstrated a decrease in the counts of WBC by 9.6% in fourteen (93.3%) patients, that of neutrophils by 4.9% in twelve (80%) patients, that of lymphocytes by 16,8% in fifteen (100%) patients, and that oi monocytes by 24% in twelve (80%) patients. The mentioned differences were statistically significant at a = 0.05. The eosinophilic counts in blood sampled from the upper and lower extremities appeared similar in 66.7% of the examined subjects. In 33.3% of cases the eosinophilic count in blood samples from crural varicose vein was by 16.7% lower than that for blood samples form the ulnar vein. No differences for the rest parameters of the clinical blood count were revealed. The absolute lymphocytic count in the blood samples taken after the 30-minute static loading from the crural varicose veins was significantly lower as compared with that in blood sampled form the cubital vein. The counts for RBCs and blood platelets, as well as other qualitative haematological indices (haemoglobin, haematocrit, average volume of the RBC, erythrocytic diameter, etc.) in blood sampled form crural and ulnar veins in the same patient were identical, thus strongly suggesting the lack of either haemodynamic or haemorheological phenomena capable of leading to redistribution of the blood formed elements in varicose veins. Hence a decrease in the counts of leukocytes and their subpopulations in blood sampled from crural varicose veins might be associated with the «leukocytic trap» phenomenon.
Ignatova, E N; Tupoleva, T A; Ovchinnikova, E N; Romanova, T Yu; Yaroslavtseva, N G; Filatov, F P; Troitskaya, V V; Kuzmina, L A; Parovichnikova, E N; Gaponova, T V; Savchenko, V G
To evaluate the detection rate of markers for hepatitis B virus (HBV) in the blood samples taken from patients with blood system diseases, by applying the current approaches to examining donated blood and its components for markers of viral infections. The investigation included blood samples from patients with blood system diseases (n=364) and donors (n=5,011). The results of laboratory screening of donated blood samples (n=13,081) were retrospectively analyzed. Commercial kits of reagents were used for immunochemical assay and polymerase chain reaction. Patients with blood system diseases were recorded to have markers of active HBV infection in 12.6% of cases, anti-HBc in 31.3%, and anti-HBs in 37.6%. A retrospective analysis of the results of screening donated blood samples showed the presence of markers for active HBV infection in 0.28% of cases. A prospective examination of blood donors revealed markers of HBV infection in 4.83% of cases, including those of active forms in 0.54% and anti-HBc in 4.79%. The markers of active HBV infection in donors were only anti-HBc IgM in 0.42% of cases. The blood samples from donors with an anti-HBs titer of >200 mIU/ml contained anti-HBc IgM in 10.5%. In the last 5-7 years, the detection rate of markers of HBV infection in the blood samples of patients with blood system diseases have remained at a high level. Screening for decreed markers fails to identify people with inapparent infections among the donors. Even high anti-HBs concentrations in the donated blood may be a risk for HBV transmission by transfusion to a recipient.
Blus, L.J.; Henny, C.J.; Hoffman, D.J.; Grove, R.A.
1993-01-01
A study of wood ducks (Aix sponsa) was conducted along the Coeur d'Alene River system in northern Idaho in 1986 and 1987. Most of this area has been subjected to severe contamination from lead and other metals from mining and smelting since the 1880s. In 1986, a preliminary study of wood duck nesting was conducted in the contaminated area; incubating hens captured in nest boxes were bled and weighed. Blood samples were used to determine lead and cadmium concentrations and physiological characteristics. In 1987, an intensive study of wood ducks involved trapping and monitoring nest boxes in the contaminated area. Blood and tissue samples were also taken from wood ducks from a reference area without known contamination from metals. Lead levels in blood and tissues of most wood ducks from the contaminated area frequently exceeded those considered hazardous to birds; maximum levels (wet weight) of lead were 8 :g g?1 in blood and 14 :g g?1 in liver. Changes in physiological characteristics constituted the only evidence of potentially adverse effects from lead. In the contaminated area, nesting success (55% unadjusted, 35% Mayfield estimate) was less than in other areas where predation was low and nest boxes were used; but lead concentrations and physiological characteristics of blood were similar in successful and unsuccessful hens. Values of ALAD, hemoglobin, and body mass were negatively correlated with blood concentrations of lead, whereas protoporphyrin was positively correlated with lead levels in the blood. Some of the protoporphyrin values (1,091 :g dl?1 in a male and 756 :g dl?1 in a female) equalled those associated with lead toxicosis in experimental birds. ALAD activity was low in most birds from the contaminated area; values of 0 were obtained from 11 birds. Lead levels in blood, ALAD, protoporphyrin, and hemoglobin were significantly different between birds from the contaminated and reference areas. Concentrations of lead in ingesta of wood ducks ranged from 0.9 to 610 :g g?1 in the contaminated area and 0.2 to 0.6 :g g?1 in the reference area. Levels of cadmium in kidneys of wood ducks ranged from 1g g?1 to 20 :g g?1 in the contaminated area and from only to 0.1 :g g?1 to 1 :g g?1 in the reference area. Cadmium concentrations were less than known effect levels.
Cesaro, Paola; Petruzziello, Lucio; Casciano, Fabio; Costamagna, Guido; Pandolfi, Franco
2014-01-01
Background/Aim. Uncomplicated diverticular disease (UDD) is a frequent condition in adults. The pathogenesis of symptoms remains unknown. Bacteria are able to interact with Toll-like receptors (TLRs) and to induce inflammation through both innate immunity and T-cell recruitment. We investigated the pattern of TLRs 2 and 4 and the intestinal homing in patients with UDD before and after a course of Rifaximin. Methods. Forty consecutive patients with UDD and 20 healthy asymptomatic subjects were enrolled. Among UDD patients, 20 were assigned to a 2-month course of treatment with Rifaximin 1.2 g/day for 15 days/month and 20 received placebo. Blood sample and colonic biopsies were obtained from patients and controls. The samples were collected and analyzed at baseline and at the end of treatment. Flow cytometry was performed using monoclonal antibodies (CD3, CD4, CD8, CD103, TCR-gamma/delta, CD14, TLR2, and TLR4). Results. In UDD, TLR2 and TLR4 expression on immune cell subpopulations from blood and mucosa of the affected colon are altered as compared with controls. Rifaximin treatment induced significant modifications of altered conditions. Conclusions. Our data show the role of TLRs in the development of inflammation in UDD. TLRs distribution is altered in UDD and these alterations are reversed after antibiotic treatment. This trial is registered with ClinicalTrials.gov: NCT02068482. PMID:25133198
Changing Patterns of Blood Borne Sepsis in Special Care Baby Unit, Khoula Hospital
Gupta, Bhaskar; El Amin, Eisa
2010-01-01
Objectives Infection is a frequent and important cause of morbidity and mortality in neonatal units all over the world. Over the years, there has been a shift in the microorganisms responsible for neonatal septicemia. This study aims to analyze the changing patterns of blood borne organisms in the neonatal unit. Methods This retrospective study was undertaken at the neonatal intensive care unit of Khoula Hospital in Muscat, Sultanate of Oman to analyze the incidence of blood borne sepsis and its changing pattern from 1997-2000. Results Out of a total 2181 admissions to the neonatal intensive care unit, 71 (3.25%) babies had positive blood culture. A reduction in the incidence of blood borne sepsis with changing patterns of organisms was seen over the period of four years with incidence of Group B Streptococcus declining from 34% in 1997-1998 to 17.8% in 1999-2000 and the incidence of CONS (Staphylococcus epidermidis) increasing from 20% in 1997-1998 to 35% in 1999-2000. Conclusion Overall, due to survival and prolonged hospitalization of extremely low birth weight babies who need frequent invasive procedures, and the use of powerful antibiotics, the incidence of Staphylococcus epidermidis which was previously thought to be non pathogenic has increased over the years in neonatal intensive care units. PMID:22125709
NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...
NHEXAS PHASE I MARYLAND STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 374 blood samples over 80 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were generally drawn o...
Bedside arterial blood gas monitoring system using fluorescent optical sensors
NASA Astrophysics Data System (ADS)
Bartnik, Daniel J.; Rymut, Russell A.
1995-05-01
We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.
Human blood RNA stabilization in samples collected and transported for a large biobank
2012-01-01
Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904
Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F
2015-11-01
To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.
Alcohol consumption and cycling in contrast to driving.
Hagemeister, Carmen; Kronmaier, Markus
2017-08-01
In Germany, the legal blood alcohol limit for cyclists is much higher (0.16 percent) than the limit for drivers (0.05 percent) - as long as no crash has occurred. The proportion of police-recorded crashes with personal damage under the influence is higher for cyclists than drivers, and the blood alcohol concentrations are higher for cyclists than drivers. 63 women and 204 men who drive a car and use a bike and drink alcohol participated in the online study. In the sample, cycling under the influence (CUI) was more frequent and was observed more frequently among friends than driving under the influence (DUI). Persons who use a particular vehicle type more often in general and when they visit friends also use it more often after alcohol consumption. Persons who drink alcohol more often cycle more often after alcohol consumption. In all aspects covered, drink cycling was seen as more acceptable and less dangerous than drink driving. Persons who cycle more often under the influence observe drink cycling more often among their friends. They think they are less of a danger to themselves and others when cycling after alcohol consumption, and they agree less with the statement that one should leave one's bike parked after alcohol consumption. The attitudes that drinking is unsafe for one's own driving and that one should leave one's car parked are important predictors of (non-)drink driving. For cycling, the most important predictors are bike use frequency and observing drink cycling among friends. Copyright © 2017 Elsevier Ltd. All rights reserved.
Reference values for 34 frequently used laboratory tests in 80-year-old men and women.
Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders
2016-10-01
Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Cannabis effects on driving skills.
Hartman, Rebecca L; Huestis, Marilyn A
2013-03-01
Cannabis is the most prevalent illicit drug identified in impaired drivers. The effects of cannabis on driving continue to be debated, making prosecution and legislation difficult. Historically, delays in sample collection, evaluating the inactive Δ(9)-tetrahydrocannabinol (THC) metabolite 11-nor-9-carboxy-THC, and polydrug use have complicated epidemiologic evaluations of driver impairment after cannabis use. We review and evaluate the current literature on cannabis' effects on driving, highlighting the epidemiologic and experimental data. Epidemiologic data show that the risk of involvement in a motor vehicle accident (MVA) increases approximately 2-fold after cannabis smoking. The adjusted risk of driver culpability also increases substantially, particularly with increased blood THC concentrations. Studies that have used urine as the biological matrix have not shown an association between cannabis and crash risk. Experimental data show that drivers attempt to compensate by driving more slowly after smoking cannabis, but control deteriorates with increasing task complexity. Cannabis smoking increases lane weaving and impaired cognitive function. Critical-tracking tests, reaction times, divided-attention tasks, and lane-position variability all show cannabis-induced impairment. Despite purported tolerance in frequent smokers, complex tasks still show impairment. Combining cannabis with alcohol enhances impairment, especially lane weaving. Differences in study designs frequently account for inconsistencies in results between studies. Participant-selection bias and confounding factors attenuate ostensible cannabis effects, but the association with MVA often retains significance. Evidence suggests recent smoking and/or blood THC concentrations 2-5 ng/mL are associated with substantial driving impairment, particularly in occasional smokers. Future cannabis-and-driving research should emphasize challenging tasks, such as divided attention, and include occasional and chronic daily cannabis smokers.
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study
Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung
2016-01-01
Background To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. Objective In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. Methods We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants’ opinions regarding patient safety, timeliness, efficiency, and usability were recorded. Results In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Conclusions Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use. PMID:27784649
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.
Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho
2016-10-26
To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use.
2013-01-01
Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies. PMID:24168095
Perichart-Perera, Otilia; Balas-Nakash, Margie; Rodríguez-Cano, Ameyalli; Muñoz-Manrique, Cinthya; Monge-Urrea, Adriana; Vadillo-Ortega, Felipe
2010-02-01
Dietary and lifestyle changes in Mexico have been linked to an increase in chronic diseases such as obesity and cardiovascular disease. Important dietary changes such as an increase in the consumption of energy-dense foods (high in oils, animal or processed fats, and sugars) have been recently reported. The objective of this study was to identify how key dietary energy sources correlated with other indexes of cardiovascular disease in a Mexican school-age population. From 2004 to 2006, a convenience sample (n=228) of 9- to 13-year-olds, 48.2% girls and 51.8% boys, from three public urban schools were included. Anthropometric, blood pressure, and dietary assessment (two multiple pass 24-hour recalls) were done. More than half of children did not meet the fruit and vegetable recommended intake. High-fat dairy foods (14% of total energy intake), refined carbohydrates (13.5%), red/processed meat (8.5%), added sugars/desserts (7%), corn tortilla (6.5%), and soft drinks/sweetened beverages (5%) were the highest dietary energy sources consumed. In a subgroup of children (n=185), a fasting blood sample was collected for biochemical analysis. A positive association was observed between glucose and diastolic blood pressure with the intake of soft drinks/sweetened beverages, insulin concentrations and the intake of white bread, and triglyceride concentrations with the intake of added fats. Unhealthful dietary energy sources are frequently consumed by these children. Culturally competent nutrition counseling should be offered to Mexican-American children and their families with a significant risk of cardiovascular disease. Efforts should be made to design and implement nutrition education and health promotion strategies in schools. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
Kühnisch, Jirko; Seto, Jong; Lange, Claudia; Schrof, Susanne; Stumpp, Sabine; Kobus, Karolina; Grohmann, Julia; Kossler, Nadine; Varga, Peter; Osswald, Monika; Emmerich, Denise; Tinschert, Sigrid; Thielemann, Falk; Duda, Georg; Seifert, Wenke; el Khassawna, Thaqif; Stevenson, David A.; Elefteriou, Florent; Kornak, Uwe; Raum, Kay; Fratzl, Peter; Mundlos, Stefan; Kolanczyk, Mateusz
2014-01-01
Bone fragility due to osteopenia, osteoporosis or debilitating focal skeletal dysplasias is a frequent observation in the Mendelian disease Neurofibromatosis type 1 (NF1). To determine the mechanisms underlying bone fragility in NF1 we analyzed two conditional mouse models, Nf1Prx1 (limb knock-out) and Nf1Col1 (osteoblast specific knock-out), as well as cortical bone samples from individuals with NF1. We examined mouse bone tissue with micro-computed tomography, qualitative and quantitative histology, mechanical tensile analysis, small-angle X-ray scattering (SAXS), energy dispersive X-ray spectroscopy (EDX), and scanning acoustic microscopy (SAM). In cortical bone of Nf1Prx1 mice we detected ectopic blood vessels that were associated with diaphyseal mineralization defects. Defective mineral binding in the proximity of blood vessels was most likely due to impaired bone collagen formation, as these areas were completely devoid of acidic matrix proteins and contained thin collagen fibers. Additionally, we found significantly reduced mechanical strength of the bone material, which was partially caused by increased osteocyte volume. Consistent with these observations, bone samples from individuals with NF1 and tibial dysplasia showed increased osteocyte lacuna volume. Reduced mechanical properties were associated with diminished matrix stiffness, as determined by SAM. In line with these observations, bone tissue from individuals with NF1 and tibial dysplasia showed heterogeneous mineralization and reduced collagen fiber thickness and packaging. Collectively, the data indicate that bone fragility in NF1 tibial dysplasia is partly due to an increased osteocyte-related micro-porosity, hypomineralization, a generalized defect of organic matrix formation, exacerbated in the regions of tensional and bending force integration, and finally persistence of ectopic blood vessels associated with localized macro-porotic bone lesions. PMID:24465906
Jessup, David A.; Johnson, Christine K.; Estes, James A.; Carlson-Bremer, Daphne; Jarman, Walter M.; Reese, Stacey; Dodd, Erin; Tinker, M. Tim; Ziccardi, Michael H.
2010-01-01
As part of tagging and ecologic research efforts in 1997 and 1998, apparently healthy sea otters of four age-sex classes in six locations in Alaska and three in California were sampled for persistent organic pollutants (POPs) and other chemicals of ecologic or environmental concern (COECs). Published techniques for the detection of POPs (specifically Σpolychlorinated biphenyls [PCBs], ΣDDTs, Σhexachlorocyclohexanes [HCHs], Σpolycyclic aromatic hydrocarbons [PAHs], Σchlordanes [CHLs], hexachlorobenzene [HCB], dieldrin, and mirex) in the tissue of dead otters were modified for use with serum from live sea otters. Toxic equivalencies (TEQs) were calculated for POPs with proven bioactivity. Strong location effects were seen for most POPs and COECs; sea otters in California generally showed higher mean concentrations than those in Alaska. Differences in contaminant concentrations were detected among age and sex classes, with high levels frequently observed in subadults. Very high levels of ΣDDT were detected in male sea otters in Elkhorn Slough, California, where strong freshwater outflow from agricultural areas occurs seasonally. All contaminants except mirex differed among Alaskan locations; only ΣDDT, HCB, and chlorpyrifos differed within California. High levels of ΣPCB (particularly larger, more persistent congeners) were detected at two locations in Alaska where associations between elevated PCBs and military activity have been established, while higher PCB levels were found at all three locations in California where no point source of PCBs has been identified. Although POP and COEC concentrations in blood may be less likely to reflect total body burden, concentrations in blood of healthy animals may be more biologically relevant and less influenced by state of nutrition or perimortem factors than other tissues routinely sampled.
Muhammad, Raj; Shakeel, Muhammad; Rehman, Shoaib U; Lodhi, Muhammad A
2017-03-01
β-Thalassemia (β-thal) is the most prevalent hereditary blood disorder in Pakistan with a carrier rate of 5.0-8.0%. The homozygous affected children require frequent blood transfusions for their survival. This autosomal recessive disease can only be prevented through awareness programs, carrier screening, mutation detection, genetic counseling and prenatal diagnosis (PND). The present study aimed to determine the prevalence of various mutations causing β-thal and also to detect carriers of these mutations in families living in the Mardan Division, Khyber Pakhtunkhwa (KP) Province, Pakistan. The study was conducted at the Department of Biochemistry, Abdul Wali Khan University Mardan, Pakistan. Blood samples of β-thalassemic families were collected from various transfusion centers in Mardan Division. Using the amplification refractory mutation system-polymerase chain reaction (ARMS-PCR) technique, all samples were analyzed for the six most common mutations causing β-thal in this area. Six different mutant primers for the detection of different mutations were used. The most common mutations detected in thalassemic patients were frameshift codons (FSC) 8/9 (+G) (HBB: c.27_28insG), codons 41/42 (-TTCT) (HBB: c.126_129delCTTT), and IVS-I-5 (G>C) (HBB: c.92+5G>C). The predominant mutation for carrying the mutant genes for β-thal were FSC 8/9, IVS-I-5, codons 41/42, IVS-I-1. It was also found that 66.7% of marriages were consanguineous. The FSC 8/9 mutation was found to be the most common β-thal mutation with a frequency of 44.4%. This research project provides a strong incentive for the establishment of large scale mutation detection and PND services in the Mardan Division.
Red blood cell and leukocyte alloimmunization in patients awaiting kidney transplantation
da Silva, Silvia Fernandes Ribeiro; Ferreira, Gláucia Maria; da Silva, Sonia Leite; Alves, Tânia Maria de Oliveira; Ribeiro, Ilana Farias; Ribeiro, Thyciana Rodrigues; Cavalcante, Maria do Carmo Serpa
2013-01-01
Objective To determine the rates of red blood cell and leukocyte alloimmunization in patients with chronic kidney disease awaiting kidney transplantation. Methods In this cross-sectional and prospective study, the serum of 393 chronic kidney disease patients on a transplant waiting list in Ceará, Northeastern Brazil were tested for red cell and leukocyte antibodies. In addition, demographic, clinical and laboratory data were collected. Results The average age in the sample of 393 patients was 34.1 ± 14 years. Slightly more than half (208; 52.9%) were male. The average numbers of transfusions and gestations were 3.1 ± 3.3 and 1.6 ± 6, respectively. One third (33.6%) were alloimmunized: 78% with leukocyte antibodies, 9.1% with red cell antibodies and 12.9% with both. Red cell antibodies were detected in 29 cases (7.4%), 17 of whom were women, who had received more transfusions than the males (p-value < 0.0001). The most frequently detected red cell antibodies belonged to the Rh (24.1%) and Kell (13.8%) blood group systems. Leukocyte antibodies were detected in 30.5% of cases, 83 of whom were women, who had received more transfusions than the males (p-value < 0.0001) and were more reactive to panel reactive antibodies (p-value < 0.0001). The mean alloreactivity to panel reactive antibodies was 47.7 ± 31.2%. Conclusion Chronic kidney disease patients on the transplant waiting list in Ceará, Brazil, display high rates of red cell (7.4%) and leukocyte (30.5%) alloimmunization. In this sample, alloimmunization was significantly associated with the number of transfusions and gender. PMID:23904808
Murphy, Malia S Q; Hawken, Steven; Atkinson, Katherine M; Milburn, Jennifer; Pervin, Jesmin; Gravett, Courtney; Stringer, Jeffrey S A; Rahman, Anisur; Lackritz, Eve; Chakraborty, Pranesh; Wilson, Kumanan
2017-01-01
Background Knowledge of gestational age (GA) is critical for guiding neonatal care and quantifying regional burdens of preterm birth. In settings where access to ultrasound dating is limited, postnatal estimates are frequently used despite the issues of accuracy associated with postnatal approaches. Newborn metabolic profiles are known to vary by severity of preterm birth. Recent work by our group and others has highlighted the accuracy of postnatal GA estimation algorithms derived from routinely collected newborn screening profiles. This protocol outlines the validation of a GA model originally developed in a North American cohort among international newborn cohorts. Methods Our primary objective is to use blood spot samples collected from infants born in Zambia and Bangladesh to evaluate our algorithm’s capacity to correctly classify GA within 1, 2, 3 and 4 weeks. Secondary objectives are to 1) determine the algorithm's accuracy in small-for-gestational-age and large-for-gestational-age infants, 2) determine its ability to correctly discriminate GA of newborns across dichotomous thresholds of preterm birth (≤34 weeks, <37 weeks GA) and 3) compare the relative performance of algorithms derived from newborn screening panels including all available analytes and those restricted to analyte subsets. The study population will consist of infants born to mothers already enrolled in one of two preterm birth cohorts in Lusaka, Zambia, and Matlab, Bangladesh. Dried blood spot samples will be collected and sent for analysis in Ontario, Canada, for model validation. Discussion This study will determine the validity of a GA estimation algorithm across ethnically diverse infant populations and assess population specific variations in newborn metabolic profiles. PMID:29104765
Steiss, Janet E; Wright, James C
2008-10-01
To determine whether Labrador Retrievers participating in field trials develop respiratory alkalosis and hypocapnia primarily in conditions of high ambient temperatures. 16 Labrador Retrievers. At each of 5 field trials, 5 to 10 dogs were monitored during a test (retrieval of birds over a variable distance on land [1,076 to 2,200 m]; 36 assessments); ambient temperatures ranged from 2.2 degrees to 29.4 degrees C. For each dog, rectal temperature was measured and a venous blood sample was collected in a heparinized syringe within 5 minutes of test completion. Blood samples were analyzed on site for Hct; pH; sodium, potassium, ionized calcium, glucose, lactate, bicarbonate, and total CO2 concentrations; and values of PvO2 and PvCO2. Scatterplots of each variable versus ambient temperature were reviewed. Regression analysis was used to evaluate the effect of ambient temperature (< or = 21 degrees C and > 21 degrees C) on each variable. Compared with findings at ambient temperatures < or = 21 degrees C, venous blood pH was increased (mean, 7.521 vs 7.349) and PvCO2 was decreased (mean, 17.8 vs 29.3 mm Hg) at temperatures > 21 degrees C; rectal temperature did not differ. Two dogs developed signs of heat stress in 1 test at an ambient temperature of 29 degrees C; their rectal temperatures were higher and PvCO2 values were lower than findings in other dogs. When running distances frequently encountered at field trials, healthy Labrador Retrievers developed hyperthermia regardless of ambient temperature. Dogs developed respiratory alkalosis and hypocapnia at ambient temperatures > 21 degrees C.
Osenenko, Katherine M; Szabo, Shelagh M; Qatami, Lara; Korenblat Donato, Bonnie M; Al Madani, Abdulrazzak Ali; Al Awadi, Fatheya Fardallah; Al-Ansari, Jaber; Maclean, Ross; Levy, Adrian R
2015-09-01
Despite the high prevalence of type 2 diabetes mellitus (T2DM), few data exist describing its management in Dubai. This study characterized the treatment and estimated levels of glycemic, lipid, and blood pressure control among a sample with T2DM at a large Dubai Hospital. This retrospective cohort study systematically sampled charts from adults seeking care for T2DM from October 2009 to March 2010 until the target (N = 250) was reached. Data on patient characteristics, pharmacotherapy, complications, and laboratory testing were abstracted until September 2011. The frequency of treatments and modifications over the period was calculated, and measures of glycosylated hemoglobin A 1c , low-density lipoprotein, and blood pressure control were compared with guideline targets. Frequencies of complications were compared according to treatment type. One-third of the cohort comprised men, and the mean age was 58 years. At enrolment, the mean time from T2DM diagnosis was nearly 15 years and 74% had received insulin. During the study period, the most common regimens were insulin + oral combinations (55%) and oral combination therapy (39%). Overall, 67% received any insulin therapy during the study; and by study end, 78% had received insulin at any time. At the most recent assessment, guideline targets for glycosylated hemoglobin A 1c , blood pressure, and low-density lipoprotein were met by 23%, 29%, and 71%, respectively. Complications were more frequent among those treated with combination or insulin therapies. This study provides baseline data from Dubai for future comparisons of the effectiveness of new treatments, and to better understand the humanistic and economic burden of T2DM and its complications. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples
2011-01-01
Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640
Dinhopl, Nora; Mostegl, Meike M.; Richter, Barbara; Nedorost, Nora; Maderner, Anton; Fragner, Karin; Weissenböck, Herbert
2011-01-01
In captive penguins, avian malaria due to Plasmodium parasites is a well-recognized disease problem as these protozoa may cause severe losses among valuable collections of zoo birds. In blood films from naturally infected birds, identification and differentiation of malaria parasites based on morphological criteria are difficult because parasitaemia is frequently light and blood stages, which are necessary for identification of parasites, are often absent. Post-mortem diagnosis by histological examination of tissue samples is sometimes inconclusive due to the difficulties in differentiating protozoal tissue stages from fragmented nuclei in necrotic tissue. The diagnosis of avian malaria would be facilitated by a technique with the ability to specifically identify developmental stages of Plasmodium in tissue samples. Thus, a chromogenic in-situ hybridization (ISH) procedure with a digoxigenin-labelled probe, targeting a fragment of the 18S rRNA, was developed for the detection of Plasmodium parasites in paraffin wax-embedded tissues. This method was validated in comparison with traditional techniques (histology, polymerase chain reaction), on various tissues from 48 captive penguins that died at the zoological garden Schönbrunn, Vienna, Austria. Meronts of Plasmodium gave clear signals and were easily identified using ISH. Potential cross-reactivity of the probe was ruled out by the negative outcome of the ISH against a number of protozoa and fungi. Thus, ISH proved to be a powerful, specific and sensitive tool for unambiguous detection of Plasmodium parasites in paraffin wax-embedded tissue samples. PMID:21711191
Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples
NASA Technical Reports Server (NTRS)
Malik, W. M.
1967-01-01
Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.
A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment.
Vutukuru, Manjula Ramya; Sharma, Divya Khandige; Ragavendar, M S; Schmolke, Susanne; Huang, Yiwei; Gumbrecht, Walter; Mitra, Nivedita
2016-12-01
Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200μL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques. Copyright © 2016 Elsevier B.V. All rights reserved.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples consisted of two 3-mL tubes. The prim...
Guatteo, R; Joly, A; Beaudeau, F
2012-03-23
To describe both shedding and serological patterns following abortions detected as being associated with Coxiella burnetii (Cb), 24 cows experiencing an abortion due to Cb were followed over a one month period. Samples taken on the day of abortion (D0) were followed 3-fold by weekly samplings from day 14 (D14) to D28 after the abortion. Milk and vaginal mucus were collected at each weekly sampling and tested using real-time PCR while blood samples were collected 2-fold on D21 and D28 and tested using ELISA. We found a very short duration of C. burnetii shedding in vaginal mucus after abortion, highlighting the need to collect samples as rapidly as possible following an abortion to avoid false negative results. In contrast with previous results, concomitancy of vaginal and mucus shedding was frequent, especially for cows shedding a high bacterial load on DO leading to the hypothesis that the clinical onset of the infection influences the modalities of Cb shedding. Lastly, serological results indicating a lack of sensitivity to detect Cb shedder cows (especially for cows for which Ct values were high) suggest that ELISA is not a useful tool to diagnose abortions at the individual level. Copyright © 2011 Elsevier B.V. All rights reserved.
Pilger, Daniel; Hauser, Andrea; Kuecherer, Claudia; Mugenyi, Kizito; Kabasinguzi, Rose; Somogyi, Sybille; Harms, Gundel; Kunz, Andrea
2011-01-01
Nevirapine single-dose (NVP-SD) reduces mother-to-child transmission of HIV type-1 (HIV-1), but frequently induces resistance mutations in the HIV-1 genome. Little is known about drug-resistant HIV-1 variants in the breast milk of women who have taken NVP-SD. Blood and breast milk samples of 39 HIV-1-infected Ugandan women were taken 6-12 weeks after NVP-SD intake. Samples were analysed by population sequencing and allele-specific real-time PCR (AS-PCR) with detection limits for NVP-resistant HIV-1 variants (K103N and Y181C) of < 1% of the total viral population. AS-PCR results for both plasma and breast milk were obtained for 19 women who constituted the final study group (HIV-1 subtype frequencies were A1 n = 11, D n = 5, G n = 2 and C n = 1). A total of 7 (37%) and 10 (53%) women carried NVP-resistant virus in breast milk and plasma, respectively. Overall, 71% (5/7) women with NVP-resistant HIV-1 in breast milk displayed >1 drug-resistant variant. Resistance in breast milk was higher at week 6 (6/13 samples [46%]) compared with week 12 (1/6 samples [17%]). In total, 10 drug-resistant populations harbouring the K103N and/or Y181C mutation were detected in the 19 breast milk samples; 7 (70%) were caused by resistant minorities (< 5% of the total HIV-1 population). In the four women with drug-resistant virus in both plasma and breast milk, the mutation patterns differed between the two compartments. Minor populations of drug-resistant HIV-1 were frequently found in breast milk of Ugandan women after exposure to NVP-SD. Further studies need to explore the role of minor drug-resistant variants in the postnatal transmission of (resistant) HIV-1.
[Identification of Animal Whole Blood Based on Near Infrared Transmission Spectroscopy].
Wan, Xiong; Wang, Jian; Liu, Peng-xi; Zhang, Ting-ting
2016-01-01
The inspection and classification for blood products are important but complicated in import-export ports or inspection and quarantine departments. For the inspection of whole blood products, open sampling can cause pollution and virulence factors in bloods samples may even endanger inspectors. Thus non-contact classification and identification methods for whole bloods of animals are needed. Spectroscopic techniques adopted in the flowcytometry need sampling blood cells during the detection; therefore they can not meet the demand of non-contact identification and classification for whole bloods of animals. Infrared absorption spectroscopy is a technique that can be used to analyze the molecular structure and chemical bonds of detected samples under the condition of non-contact. To find a feasible spectroscopic approach of non-contact detection for the species variation in whole blood samples, a near infrared transmitted spectra (NITS, 4 497.669 - 7 506.4 cm(-1)) experiment of whole blood samples of three common animals including chickens, dogs and cats has been conducted. During the experiment, the spectroscopic resolution is 5 cm(-1), and each spectrogram is an average of 5 measured spectral data. Experimental results show that all samples have a sharp absorption peak between 5 184 and 5 215 cm(-1), and a gentle absorption peak near 7 000 cm(-1). Besides, the NITS curves of different samples of same animals are similar, and only have slight differences in the whole transmittance. A correlation coefficient (CC) is induced to distinguish the differences of the three animals' whole bloods in NITS curves, and the computed CCs between NITS curves of different samples of the same animals, are greater than 0.99, whereas CCs between NITS curves of the whole bloods of different animals are from 0.509 48 to 0.916 13. Among which CCs between NITS curves of the whole bloods of chickens and cats are from 0.857 23 to 0.912 44, CCs between NITS curves of the whole bloods of chickens and dogs are from 0.509 48 to 0.664 82, and CCs between NITS curves of the whole bloods of cats and dogs are from 0.872 75 to 0.916 13. The cat and the dog belong to the class of mammal, and the CCs between their whole bloods NITS curves are greater than those between chickens and cats, or chickens and dogs, which are hetero-class animals. Namely, the whole bloods NITS curves of the cat and the dog have higher similarity. These results of NITS provide a feasible method of non-contact identification of animal whole bloods.
Westenbrink, W
1992-01-01
Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.
Congleton, J.L.; LaVoie, W.J.
2001-01-01
Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.
Epidemiological characterization of lumpy skin disease outbreaks in Russia in 2016.
Sprygin, A; Artyuchova, E; Babin, Y; Prutnikov, P; Kostrova, E; Byadovskaya, O; Kononov, A
2018-05-10
In 2015, the lumpy skin disease virus spread throughout the Russian Federation. Following a modified stamping-out campaign, the disease re-emerged with a greater incidence across 16 regions of Southern and Central Russia. A total of 313 outbreaks were reported to OIE. The highest outbreak frequency was observed in the republics of Chechnya (108), Kalmykiya (57), and Ingushetiya (35). The disease cases predominantly occurred in June and July 2016, starting from May to December; however, no association between outbreaks and altitudes was identified (p > .05). Samples taken from infected cattle were subjected to PCR analysis, which identified the genome of the virus most frequently in skin nodules (78%), nasal swabs (23.4%), blood (13%) and sera (14.5%). Interestingly, LSDV genome was occasionally identified in lung and milk samples. Based on the PRO30 sequence analysis, lumpy skin disease virus (LSDV) strains circulating in Russia were all identical and fell within the cluster of field LSDV found worldwide. © 2018 Blackwell Verlag GmbH.
NHEXAS PHASE I REGION 5 STUDY--METALS IN BLOOD ANALYTICAL RESULTS
This data set includes analytical results for measurements of metals in 165 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood samples were collected by venipun...
NHEXAS PHASE I REGION 5 STUDY--VOCS IN BLOOD ANALYTICAL RESULTS
This data set includes analytical results for measurements of VOCs (volatile organic compounds) in 145 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood sample...
Mosher, Ruby A; Coetzee, Johann F; Allen, Portia S; Havel, James A; Griffith, Gary R; Wang, Chong
2014-02-01
To determine the effects of protease inhibitors and holding times and temperatures before processing on the stability of substance P in bovine blood samples. Blood samples obtained from a healthy 6-month-old calf. Blood samples were dispensed into tubes containing exogenous substance P and 1 of 6 degradative enzyme inhibitor treatments: heparin, EDTA, EDTA with 1 of 2 concentrations of aprotinin, or EDTA with 1 of 2 concentrations of a commercially available protease inhibitor cocktail. Plasma was harvested immediately following collection or after 1, 3, 6, 12, or 24 hours of holding at ambient (20.3° to 25.4°C) or ice bath temperatures. Total substance P immunoreactivity was determined with an ELISA; concentrations of the substance P parent molecule, a metabolite composed of the 9 terminal amino acids, and a metabolite composed of the 5 terminal amino acids were determined with liquid chromatography-tandem mass spectrometry. Regarding blood samples processed immediately, no significant differences in substance P concentrations or immunoreactivity were detected among enzyme inhibitor treatments. In blood samples processed at 1 hour of holding, substance P parent molecule concentration was significantly lower for ambient temperature versus ice bath temperature holding conditions; aprotinin was the most effective inhibitor of substance P degradation at the ice bath temperature. The ELISA substance P immunoreactivity was typically lower for blood samples with heparin versus samples with other inhibitors processed at 1 hour of holding in either temperature condition. Results suggested that blood samples should be chilled and plasma harvested within 1 hour after collection to prevent substance P degradation.
Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine
2010-09-01
Scand J Caring Sci; 2010; 24; 581-591 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory. To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories. Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing. The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff. The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.
Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew
2007-01-01
The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.
Moore, Carmel; Sambrook, Jennifer; Walker, Matthew; Tolkien, Zoe; Kaptoge, Stephen; Allen, David; Mehenny, Susan; Mant, Jonathan; Di Angelantonio, Emanuele; Thompson, Simon G; Ouwehand, Willem; Roberts, David J; Danesh, John
2014-09-17
Ageing populations may demand more blood transfusions, but the blood supply could be limited by difficulties in attracting and retaining a decreasing pool of younger donors. One approach to increase blood supply is to collect blood more frequently from existing donors. If more donations could be safely collected in this manner at marginal cost, then it would be of considerable benefit to blood services. National Health Service (NHS) Blood and Transplant in England currently allows men to donate up to every 12 weeks and women to donate up to every 16 weeks. In contrast, some other European countries allow donations as frequently as every 8 weeks for men and every 10 weeks for women. The primary aim of the INTERVAL trial is to determine whether donation intervals can be safely and acceptably decreased to optimise blood supply whilst maintaining the health of donors. INTERVAL is a randomised trial of whole blood donors enrolled from all 25 static centres of NHS Blood and Transplant. Recruitment of about 50,000 male and female donors started in June 2012 and was completed in June 2014. Men have been randomly assigned to standard 12-week versus 10-week versus 8-week inter-donation intervals, while women have been assigned to standard 16-week versus 14-week versus 12-week inter-donation intervals. Sex-specific comparisons will be made by intention-to-treat analysis of outcomes assessed after two years of intervention. The primary outcome is the number of blood donations made. A key secondary outcome is donor quality of life, assessed using the Short Form Health Survey. Additional secondary endpoints include the number of 'deferrals' due to low haemoglobin (and other factors), iron status, cognitive function, physical activity, and donor attitudes. A comprehensive health economic analysis will be undertaken. The INTERVAL trial should yield novel information about the effect of inter-donation intervals on blood supply, acceptability, and donors' physical and mental well-being. The study will generate scientific evidence to help formulate blood collection policies in England and elsewhere. Current Controlled Trials ISRCTN24760606, 25 January 2012.
Compression and flexural strength of bone cement mixed with blood.
Tan, J H; Koh, B Th; Ramruttun, A K; Wang, W
2016-08-01
To assess the compression and flexural strength of bone cement mixed with 0 ml, 1 ml, or 2 ml of blood. High viscosity polymethyl methacrylate (PMMA) loaded with or without gentamicin was used. Blood was collected from total knee arthroplasty patients. In the same operating room, one pack of cement each was mixed with 0 ml (control), 1 ml, or 2 ml of blood for 1 minute during the dough phase. The dough was extruded into cylindrical and rectangular moulds for 20 minutes of setting, and then cured in phosphate buffered saline at 37±1ºC for 7 days. The samples were visually inspected for fractures and areas of weakness, and then scanned using microcomputed tomography. 48 gentamicin-loaded and 59 non-gentamicin-loaded samples mixed with 0 ml (control), 1 ml, or 2 ml of blood were randomised for flexural and compression strength testing; each group had at least 6 samples. In samples loaded with or without gentamicin, the flexural and compressive strength was highest in controls, followed by samples mixed with 1 ml or 2 ml of blood. In samples mixed with 2 ml of blood, the flexural strength fell below the standard of 50 MPa. In samples mixed with 2 ml of blood and all gentamicin-loaded samples, the compressive strength fell below the standard of 70 MPa. Microcomputed tomography revealed areas of voids and pores indicating the presence of laminations and partitions within. The biomechanical strength of PMMA contaminated with blood may decrease. Precautions such as saline lavage, pack drying the bone, change of gloves, and prompt insertion of the implant should be taken to prevent blood from contaminating bone cement.
Integrated Blood Barcode Chips
Fan, Rong; Vermesh, Ophir; Srivastava, Alok; Yen, Brian K.H.; Qin, Lidong; Ahmad, Habib; Kwong, Gabriel A.; Liu, Chao-Chao; Gould, Juliane; Hood, Leroy; Heath, James R.
2008-01-01
Blood comprises the largest version of the human proteome1. Changes of plasma protein profiles can reflect physiological or pathological conditions associated with many human diseases, making blood the most important fluid for clinical diagnostics2-4. Nevertheless, only a handful of plasma proteins are utilized in routine clinical tests. This is due to a host of reasons, including the intrinsic complexity of the plasma proteome1, the heterogeneity of human diseases and the fast kinetics associated with protein degradation in sampled blood5. Simple technologies that can sensitively sample large numbers of proteins over broad concentration ranges, from small amounts of blood, and within minutes of sample collection, would assist in solving these problems. Herein, we report on an integrated microfluidic system, called the Integrated Blood Barcode Chip (IBBC). It enables on-chip blood separation and the rapid measurement of a panel of plasma proteins from small quantities of blood samples including a fingerprick of whole blood. This platform holds potential for inexpensive, non-invasive, and informative clinical diagnoses, particularly, for point-of-care. PMID:19029914
[Obstructive sleep apnea syndrome, hypertension and artery].
Baguet, Jean-Philippe; Barone-Rochette, Gilles; Pépin, Jean-Louis
2009-04-01
Obstructive sleep apnea syndrome (OSAS), due to upper airway collapse, is frequent but still underestimated. The dose-response relation between OSAS and hypertension (HTN) is now well established. Logically, therefore, blood pressure must be tested in every apneic patient, if necessary by ambulatory blood pressure monitoring. Multiple mechanisms explain this relation, most importantly the increase in sympathetic activity during apnea episodes. OSAS-related hypertension has several characteristics: it is highly prevalent, predominantly diastolic and nocturnal, and frequently affects non-dippers; and the HTN tends to be resistant to treatment. OSAS promotes the formation of arterial lesions (parietal thickening of the carotid artery, increased aortic stiffness, and endothelial dysfunction); the more severe the OSAS, the more severe the lesions. The beneficial effects on blood pressure of continuous positive airway pressure (CPAP), the benchmark treatment for OSAS, are still debated but appear to be significant for untreated or refractory hypertension, for severe OSAS, and when CPAP compliance is good. It also seems promising for the reduction of arterial lesions linked to OSAS.
NASA Astrophysics Data System (ADS)
Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.
2016-05-01
Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.
Whole blood analysis rotor assembly having removable cellular sedimentation bowl
Burtis, C.A.; Johnson, W.F.
1975-08-26
A rotor assembly for performing photometric analyses using whole blood samples is described. Following static loading of a gross blood sample within a centrally located, removable, cell sedimentation bowl, the red blood cells in the gross sample are centrifugally separated from the plasma, the plasm displaced from the sedimentation bowl, and measured subvolumes of plasma distributed to respective sample analysis cuvettes positioned in an annular array about the rotor periphery. Means for adding reagents to the respective cuvettes are also described. (auth)
Putnam, Larry D.; Hoogestraat, Galen K.; Sawyer, J. Foster
2008-01-01
Onsite wastewater disposal systems (OWDS) are used extensively in the Black Hills of South Dakota where many of the watersheds and aquifers are characterized by fractured or solution-enhanced bedrock with thin soil cover. A study was conducted during 2006-08 to characterize water-quality effects and indicators of OWDS. Water samples were collected and analyzed for potential indicators of OWDS, including chloride, bromide, boron, nitrite plus nitrate (NO2+NO3), ammonia, major ions, nutrients, selected trace elements, isotopes of nitrate, microbiological indicators, and organic wastewater compounds (OWCs). The microbiological indicators were fecal coliforms, Escherichia coli (E. coli), enterococci, Clostridium perfringens (C. perfringens), and coliphages. Sixty ground-water sampling sites were located either downgradient from areas of dense OWDS or in background areas and included 25 monitoring wells, 34 private wells, and 1 spring. Nine surface-water sampling sites were located on selected streams and tributaries either downstream or upstream from residential development within the Precambrian setting. Sampling results were grouped by their hydrogeologic setting: alluvial, Spearfish, Minnekahta, and Precambrian. Mean downgradient dissolved NO2+NO3 concentrations in ground water for the alluvial, Spearfish, Minnekahta, and Precambrian settings were 0.734, 7.90, 8.62, and 2.25 milligrams per liter (mg/L), respectively. Mean downgradient dissolved chloride concentrations in ground water for these settings were 324, 89.6, 498, and 33.2 mg/L, respectively. Mean downgradient dissolved boron concentrations in ground water for these settings were 736, 53, 64, and 43 micrograms per liter (ug/L), respectively. Mean dissolved surface-water concentrations for NO2+NO3, chloride, and boron for downstream sites were 0.222 mg/L, 32.1 mg/L, and 28 ug/L, respectively. Mean values of delta-15N and delta-18O (isotope ratios of 14N to 15N and 18O to 16O relative to standard ratios) for nitrate in ground-water samples were 10.4 and -2.0 per mil (0/100), respectively, indicating a relatively small contribution from synthetic fertilizer and probably a substantial contribution from OWDS. The surface-water sample with the highest dissolved NO2+NO3 concentration of 1.6 mg/L had a delta-15N value of 12.36 0/100, which indicates warm-blooded animals (including humans) as the nitrate source. Fecal coliforms were detected in downgradient ground water most frequently in the Spearfish (19 percent) and Minnekahta (9.7 percent) settings. E. coli was detected most frequently in the Minnekahta (29 percent) and Spearfish (13 percent) settings. Enterococci were detected more frequently than other microbiological indicators in all four settings. Fecal coliforms and E. coli were detected in 73 percent and 95 percent of all surface-water samples, respectively. Enterococci, coliphages (somatic), and C. perfringens were detected in 50, 70, and 50 percent of surface-water samples, respectively. Of the 62 OWC analytes, 12 were detected only in environmental samples, 10 were detected in at least one environmental and one blank sample (not necessarily companion pairs), 2 were detected only in blank samples, and 38 were not detected in any blank, environmental, or replicate sample from either ground or surface water. Eleven different organic compounds were detected in ground-water samples at eight different sites. The most frequently occurring compound was DEET, which was found in 32 percent of the environmental samples, followed by tetrachloroethene, which was detected in 20 percent of the samples. For surface-water samples, 16 organic compounds were detected in 9 of the 10 total samples. The compound with the highest occurrence in surface-water samples was camphor, which was detected in 50 percent of samples. The alluvial setting was characterized by relatively low dissolved NO2+NO3 concentrations, detection of ammonia nitrogen, and relatively high concentr
Vasků, A; Soucek, M; Goldbergová, M; Vácha, J
2003-01-01
The aim of the study was to assess the association between promoter polymorphism [A(-596)G] in interleukin-6 gene and office systolic and diastolic blood pressures, and the heart rate (HR) in apparently healthy Czech subjects. Furthermore, we evaluated the possible influence of gender, BMI and smoking on these supposed associations. An age-matched (40-50 years) and gender-matched (F/M=81/89) sample of apparently healthy Czech subjects (n=170, F/M=81/89) without hypertension, other cardiovascular diseases or diabetes was examined. The A(-596)G Il-6 gene polymorphism was detected by the PCR method. No differences in genotype distribution and/or allelic frequency was found between groups with lower systolic blood pressure (Ł 122 mm Hg) and higher systolic blood pressure (> 122 mm Hg). Similarly, no differences in the IL-6 polymorphism were found between lower (Ł 86 mm Hg) and higher (> 86 mm Hg) diastolic blood pressure groups. However, we proved a significant increase of genotypes AG+GG as well as the allele (-596)G in higher (>78 beats/min) heart rate group. The genotypes AG+GG represent significantly higher relative risk for higher HR frequency, especially in women. Among lean persons with a low heart rate frequency, fewer AG+GG genotypes were determined than among any other subjects. The genotypes AG+GG are more frequent in non-smoking persons with higher HR compared to non-smoking subjects with lower HR, especially in women. Gender, BMI and smoking substantially modify the distribution of A(-596)G Il-6 gene polymorphism in apparently healthy persons with lower or higher heart rate.
Kika, T M; Lepira, F B; Kayembe, P K; Makulo, J R; Sumaili, E K; Kintoki, E V; M'Buyamba-Kabangu, J R
Uncontrolled hypertension remains an important issue in daily clinical practice worldwide. Although the majority of patients are treated in primary care, most of the data on blood pressure control originate from population-based studies or secondary healthcare. The aim of this study was to evaluate the frequency of uncontrolled hypertension and associated risk factors among hypertensive patients followed at primary care facilities in Kinshasa, the capital city of Democratic Republic of the Congo. A sample of 298 hypertensive patients seen at primary healthcare facilities, 90 men and 208 women, aged ≥ 18 years, were consecutively included in this cross-sectional study. The majority (66%) was receiving monotherapy, and diuretics (43%) were the most used drugs. According to 2007 European Society of Hypertension/European Society of Cardiology hypertension guidelines, uncontrolled hypertension was defined as blood pressure ≥ 140/90 or ≥ 130/80 mmHg (diabetes or chronic kidney disease). Logistic regression analysis was used to identify the determinants of uncontrolled hypertension. Uncontrolled hypertension was observed in 231 patients (77.5%), 72 men and 159 women. Uncontrolled systolic blood pressure (SBP) was more frequent than uncontrolled diastolic blood pressure (DBP) and increased significantly with advancing age (p = 0.002). The proportion of uncontrolled SBP and DBP was significantly higher in patients with renal failure (p = 0.01) and those with high (p = 0.03) to very high (p = 0.02) absolute cardiovascular risk. The metabolic syndrome (OR 2.40; 95% CI 1.01-5.74; p = 0.04) emerged as the main risk factor associated with uncontrolled hypertension. Uncontrolled hypertension was common in this case series and was associated with factors related to lifestyle and diet, which interact with blood pressure control.
Lindsay, Holly; Bhar, Saleh; Bonifant, Challice; Sartain, Sarah; Whittle, Sarah B.; Lee-Kim, Youngna; Shah, Mona D.
2018-01-01
Paediatric haematology, oncology and bone marrow transplant (BMT) patients frequently require transfusion of blood products. Our institution required a new transfusion consent be obtained every admission. The objectives of this project were to: revise inpatient blood products consent form to be valid for 1 year, decrease provider time spent consenting from 15 to <5 min per admission, and improve provider frustration with the consent process. Over 6 months, we determined the average number of hospitalisations requiring transfusions in a random sampling of haematology/oncology/BMT inpatients. We surveyed nurses and providers regarding frustration levels and contact required regarding consents. Four and 12 months after implementation of the annual consent, providers and nurses were resurveyed, and new inpatient cohorts were assessed. Comparison of preintervention and postintervention time data allowed calculation of provider time reduction, a surrogate measure of improved work efficiency. Prior to the annual consent, >33 hours were spent over 6 months obtaining consent on 40 patients, with >19 hours spent obtaining consent when no transfusions were administered during admission. Twelve months after annual consent implementation, 97.5% (39/40) of analysed patients had a completed annual blood products transfusion consent and provider work efficiency had improved by 94.6% (>30 hours). Although several surveyed variables improved following annual consent implementation, provider frustration with consent process remained 6 out of a max score of 10, the same level as prior to the intervention. Development of an annual inpatient blood products consent form decreased provider time from 15 to <1 min per admission, decreased consenting numbers and increased work efficiency by >90%. PMID:29333497
Lindsay, Holly; Bhar, Saleh; Bonifant, Challice; Sartain, Sarah; Whittle, Sarah B; Lee-Kim, Youngna; Shah, Mona D
2018-01-01
Paediatric haematology, oncology and bone marrow transplant (BMT) patients frequently require transfusion of blood products. Our institution required a new transfusion consent be obtained every admission. The objectives of this project were to: revise inpatient blood products consent form to be valid for 1 year, decrease provider time spent consenting from 15 to <5 min per admission, and improve provider frustration with the consent process. Over 6 months, we determined the average number of hospitalisations requiring transfusions in a random sampling of haematology/oncology/BMT inpatients. We surveyed nurses and providers regarding frustration levels and contact required regarding consents. Four and 12 months after implementation of the annual consent, providers and nurses were resurveyed, and new inpatient cohorts were assessed. Comparison of preintervention and postintervention time data allowed calculation of provider time reduction, a surrogate measure of improved work efficiency. Prior to the annual consent, >33 hours were spent over 6 months obtaining consent on 40 patients, with >19 hours spent obtaining consent when no transfusions were administered during admission. Twelve months after annual consent implementation, 97.5% (39/40) of analysed patients had a completed annual blood products transfusion consent and provider work efficiency had improved by 94.6% (>30 hours). Although several surveyed variables improved following annual consent implementation, provider frustration with consent process remained 6 out of a max score of 10, the same level as prior to the intervention. Development of an annual inpatient blood products consent form decreased provider time from 15 to <1 min per admission, decreased consenting numbers and increased work efficiency by >90%.
Mechanisms of red blood cells agglutination in antibody-treated paper.
Jarujamrus, Purim; Tian, Junfei; Li, Xu; Siripinyanond, Atitaya; Shiowatana, Juwadee; Shen, Wei
2012-05-07
Recent reports on using bio-active paper and bio-active thread to determine human blood type have shown a tremendous potential of using these low-cost materials to build bio-sensors for blood diagnosis. In this work we focus on understanding the mechanisms of red blood cell agglutination in the antibody-loaded paper. We semi-quantitatively evaluate the percentage of antibody molecules that are adsorbed on cellulose fibres and can potentially immobilize red blood cells on the fibre surface, and the percentage of the molecules that can desorb from the cellulose fibre surface into the blood sample and cause haemagglutination reaction in the bulk of a blood sample. Our results show that 34 to 42% of antibody molecules in the papers treated with commercial blood grouping antibodies can desorb from the fibre surface. When specific antibody molecules are released into the blood sample via desorption, haemagglutination reaction occurs in the blood sample. The reaction bridges the red cells in the blood sample bulk to the layer of red cells immobilized on the fibre surface by the adsorbed antibody molecules. The desorbed antibody also causes agglutinated lumps of red blood cells to form. These lumps cannot pass through the pores of the filter paper. The immobilization and filtration of agglutinated red cells give reproducible identification of positive haemagglutination reaction. Results from this study provide information for designing new bio-active paper-based devices for human blood typing with improved sensitivity and specificity.
NASA Astrophysics Data System (ADS)
Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.
2018-01-01
Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.
Low central venous pressure with milrinone during living donor hepatectomy.
Ryu, H-G; Nahm, F S; Sohn, H-M; Jeong, E-J; Jung, C-W
2010-04-01
Maintaining a low central venous pressure (CVP) has been frequently used in liver resections to reduce blood loss. However, decreased preload carries potential risks such as hemodynamic instability. We hypothesized that a low CVP with milrinone would provide a better surgical environment and hemodynamic stability during living donor hepatectomy. Thirty-eight healthy adult liver donors were randomized to receive either milrinone (milrinone group, n = 19) or normal saline (control group, n = 19) infusion during liver resection. The surgical field was assessed using a four-point scale. Intraoperative vital signs, blood loss, the use of vasopressors and diuretics and postoperative laboratory data were compared between groups. The milrinone group showed a superior surgical field (p < 0.001) and less blood loss (142 +/- 129 mL vs. 378 +/- 167 mL, p < 0.001). Vital signs were well maintained in both groups but the milrinone group required smaller amounts of vasopressors and less-frequent diuretics to maintain a low CVP. The milrinone group also showed a more rapid recovery pattern after surgery. Milrinone-induced low CVP improves the surgical field with less blood loss during living donor hepatectomy and also has favorable effects on intraoperative hemodynamics and postoperative recovery.
The Pesticides and PCBs in Blood data set contains analytical results for measurements of up to 11 pesticides and up to 36 PCBs in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples co...
Bruggeman, Jason E; Route, William T; Redig, Patrick T; Key, Rebecca L
2018-04-10
Most studies examining bald eagle (Haliaeetus leucocephalus) exposure to lead (Pb) have focused on adults that ingested spent Pb ammunition during the fall hunting season, often at clinical or lethal levels. We sampled live bald eagle nestlings along waterbodies to quantify Pb concentrations in 3 national park units and 2 nearby study areas in the western Great Lakes region. We collected 367 bald eagle nestling feather samples over 8 years during spring 2006-2015 and 188 whole blood samples over 4 years during spring 2010-2015. We used Tobit regression models to quantify relationships between Pb concentrations in nestling feathers and blood using study area, year, and nestling attributes as covariates. Pb in nestling feather samples decreased from 2006 to 2015, but there was no trend for Pb in blood samples. Pb concentrations in nestling feather and blood samples were significantly higher in study areas located closer to and within urban areas. Pb in feather and blood samples from the same nestling was positively correlated. Pb in feathers increased with nestling age, but this relationship was not observed for blood. Our results reflect how Pb accumulates in tissues as nestlings grow, with Pb in feathers and blood indexing exposure during feather development and before sampling, respectively. Some nestlings had Pb concentrations in blood that suggested a greater risk to sublethal effects from Pb exposure. Our data provides baselines for Pb concentrations in feathers and blood of nestling bald eagles from a variety of waterbody types spanning remote, lightly populated, and human-dominated landscapes.
Device and method for automated separation of a sample of whole blood into aliquots
Burtis, Carl A.; Johnson, Wayne F.
1989-01-01
A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.
... better than treating it. Vaccines are available to prevent pneumococcal pneumonia and the flu. Other preventive measures include washing your hands frequently and not smoking. NIH: National Heart, Lung, and Blood Institute
[Blood sampling using "dried blood spot": a clinical biology revolution underway?].
Hirtz, Christophe; Lehmann, Sylvain
2015-01-01
Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.
de Las Hazas, María Carmen López; Motilva, Maria José; Piñol, Carme; Macià, Alba
2016-10-01
In this study, a fast and simple blood sampling and sample pre-treatment method based on the use of the dried blood spot (DBS) cards and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) for the quantification of olive oil phenolic metabolites in human blood was developed and validated. After validation, the method was applied to determine hydroxytyrosol metabolites in human blood samples after the acute intake of an olive oil phenolic extract. Using the FTA DMPK-A DBS card under optimum conditions, with 20µL as the blood solution volume, 100µL of methanol/Milli-Q water (50/50, v/v) as the extraction solvent and 7 disks punched out from the card, the main hydroxytyrosol metabolites (hydroxytyrosol-3-O-sulphate and hydroxytyrosol acetate sulphate) were identified and quantified. The developed methodology allowed detecting and quantifying the generated metabolites at low μM levels. The proposed method is a significant improvement over existing methods to determine phenolic metabolites circulating in blood and plasma samples, thus making blood sampling possible with the volunteer pricking their own finger, and the subsequent storage of the blood in the DBS cards prior to chromatographic analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Teranishi, Hideto; Ohzono, Nanae; Inamura, Norikazu; Kato, Atsushi; Wakabayashi, Tokio; Akaike, Hiroto; Terada, Kihei; Ouchi, Kazunobu
2015-03-01
Febrile neutropenia is the main treatment-related cause of mortality in cancer patients. During June 2012 to April 2014, 97 blood culture samples were collected from patients receiving chemotherapy for hematological malignancy and cancer with febrile neutropenia episodes (FNEs). The samples were examined for the presence of bacteria and fungi using real-time PCR amplification and sequencing of 16S and 18S rRNA genes. Bacteria were identified in 20 of 97 samples (20.6%) by the real-time PCR assay and in 10 of 97 (10.3%) samples by blood culture. In 6 blood culture-positive samples, the real-time PCR assay detected the same type of bacteria. No fungi were detected by the real-time PCR assay or blood culture. During antibiotic therapy, all samples were negative by blood culture, but the real-time PCR assay yielded a positive result in 2 cases of 2 (100%). The bacterial DNA copy number was not well correlated with the serum C-reactive protein titer of patients with FNEs. We conclude that a real-time PCR assay could provide better detection of causative microbes' in a shorter time, and with a smaller blood sample than blood culture. Using a real-time PCR assay in combination with blood culture could improve microbiological documentation of FNEs. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Non-terminal blood sampling techniques in guinea pigs.
Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens
2014-10-11
Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.
The counting of native blood cells by digital microscopy
NASA Astrophysics Data System (ADS)
Torbin, S. O.; Doubrovski, V. A.; Zabenkov, I. V.; Tsareva, O. E.
2017-03-01
An algorithm for photographic images processing of blood samples in its native state was developed to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cells' samples. Special "photo templates" were suggested to use in order to identify red blood cells. The effect of "highlighting" of leukocytes, which was found by authors, was used to increase the accuracy of this type of cells counting. Finally to raise the resolution of platelets from leukocytes the areas of their photo images were used, but not their sizes. It is shown that the accuracy of cells counting for native blood samples may be comparable with the accuracy of similar studies for smears. At the same time the proposed native blood analysis simplifies greatly the procedure of sample preparation in comparison to smear, permits to move from the detection of blood cells ratio to the determination of their concentrations in the sample.
Blood Pressure Regulation: Every Adaptation is an Integration?
Joyner, Michael J.; Limberg, Jacqueline K.
2013-01-01
This focused review serves to explore relevant issues in regard to blood pressure regulation and by doing so, provides the initial stimulus paper for the Thematic Review series “Blood Pressure Regulation” to be published in the European Journal of Applied Physiology over the coming months. In this introduction, we highlight how variable normal blood pressure can be and challenge the reader to take another look at some key concepts related to blood pressure regulation. We point out that there is frequently an underappreciated balance between peripheral vasodilation and systemic blood pressure regulation and ask the question: Are changes in blood pressure, in effect, reasonable and integrated adaptations to the physiological challenge at hand? We conclude with the idea that blood pressure regulatory systems are both flexible and redundant; ensuring a wide variety of activities associated with life can be accompanied by a perfusion pressure that can serve multiple masters. PMID:23558925
Akers, D Brad; MacCarthy, Michael F; Cunningham, Jeffrey A; Annis, Jonathan; Mihelcic, James R
2015-03-03
Thousands of households in coastal Madagascar rely on locally manufactured pitcher-pump systems to provide water for drinking, cooking, and household use. These pumps typically include components made from lead (Pb). In this study, concentrations of Pb in water were monitored at 18 household pitcher pumps in the city of Tamatave over three sampling campaigns. Concentrations of Pb frequently exceeded the World Health Organization's provisional guideline for drinking water of 10 μg/L. Under first-draw conditions (i.e., after a pump had been inactive for 1 h), 67% of samples analyzed were in excess of 10 μg/L Pb, with a median concentration of 13 μg/L. However, flushing the pump systems before collecting water resulted in a statistically significant (p < 0.0001) decrease in Pb concentrations: 35% of samples collected after flushing exceeded 10 μg/L, with a median concentration of 9 μg/L. Based on measured Pb concentrations, a biokinetic model estimates that anywhere from 15% to 70% of children living in households with pitcher pumps may be at risk for elevated blood lead levels (>5 μg/dL). Measured Pb concentrations in water were not correlated at statistically significant levels with pump-system age, well depth, system manufacturer, or season of sample collection; only the contact time (i.e., flushed or first-draw condition) was observed to correlate significantly with Pb concentrations. In two of the 18 systems, Pb valve weights were replaced with iron, which decreased the observed Pb concentrations in the water by 57-89% in one pump and by 89-96% in the other. Both systems produced samples exclusively below 10 μg/L after substitution. Therefore, relatively straightforward operational changes on the part of the pump-system manufacturers and pump users might reduce Pb exposure, thereby helping to ensure the continued sustainability of pitcher pumps in Madagascar.
Jones, Trevor G.; Warber, Kimbrough D.; Roberts, Billy D.
2010-01-01
Background Hemoglobin A1c (HbA1c) has been endorsed as a tool for the diagnosis of diabetes. This test requires instrumentation that may not be available in underdeveloped areas. Dried blood spot (DBS) samples collected by finger stick procedures offer a mechanism to transport samples to laboratories that do measure HbA1c. Methods Whole blood (ethylenediaminetetraacetic acid) was applied to Ahlstrom 226 filter paper. These DBS samples were compared to whole blood samples using the Roche Tina-quant® II immunoturbidometric assay. Hemoglobin A1c stability on DBS was assessed at three temperatures—4, 25, and 40°C—for up to 9 days. A 44-day study was also done for DBS at 20–25°C. Results The Tina-quant® II DBS method showed excellent agreement with whole blood HbA1c results (r2 = 0.99) with a slight positive mean bias of 0.08 ± 0.04% HbA1c (95% confidence interval). The variation in HbA1c on DBS samples subjected to different temperatures and times did not exceed 5.6%. Conclusions Dried blood spot samples represent an alternative to whole blood for HbA1c by measurement when transporting whole blood is not feasible. PMID:20307383
van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H
2017-10-01
In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Quasi-static acoustic tweezing thromboelastometry.
Holt, R G; Luo, D; Gruver, N; Khismatullin, D B
2017-07-01
Essentials Blood coagulation measurement during contact with an artificial surface leads to unreliable data. Acoustic tweezing thromboelastometry is a novel non-contact method for coagulation monitoring. This method detects differences in the blood coagulation state within 10 min. Coagulation data were obtained using a much smaller sample volume (4 μL) than currently used. Background Thromboelastography is widely used as a tool to assess the coagulation status of critical care patients. It allows observation of changes in material properties of whole blood, beginning with early stages of clot formation and ending with clot lysis. However, the contact activation of the coagulation cascade at surfaces of thromboelastographic systems leads to inherent variability and unreliability in predicting bleeding or thrombosis risks. Objectives To develop acoustic tweezing thromboelastometry as a non-contact method for perioperative assessment of blood coagulation. Methods Acoustic tweezing is used to levitate microliter drops of biopolymer and human blood samples. By quasi-statically changing the acoustic pressure we control the sample drop location and deformation. Sample size, deformation and location are determined by digital imaging at each pressure. Results Simple Newtonian liquid solutions maintain a constant, reversible location vs. deformation curve. In contrast, the location/deformation curves for gelatin, alginate, whole blood and blood plasma uniquely change as the samples solidify. Increasing elasticity causes the sample to deform less, leading to steeper stress/strain curves. By extracting a linear regime slope, we show that whole blood or blood plasma exhibits a unique slope profile as it begins to clot. By exposing blood samples to pro- or antithrombotic agents, the slope profile changes, allowing detection of hyper- or hypocoagulable states. Conclusions We demonstrate that quasi-static acoustic tweezing can yield information about clotting onset, maturation and strength. The advantages of small sample size, non-contact and rapid measurement make this technique desirable for real-time monitoring of blood coagulation. © 2017 International Society on Thrombosis and Haemostasis.
Elbashir, Ahmed B; Abdelbagi, Azhari O; Hammad, Ahmed M A; Elzorgani, Gafar A; Laing, Mark D
2015-03-01
Ninety-six human blood samples were collected from six locations that represent areas of intensive pesticide use in Sudan, which included irrigated cotton schemes (Wad Medani, Hasaheesa, Elmanagil, and Elfaw) and sugarcane schemes (Kenana and Gunaid). Blood samples were analyzed for organochlorine pesticide residues by gas liquid chromatography (GLC) equipped with an electron capture detector (ECD). Residues of p,p'-dichlorodiphenyldichloroethylene (DDE), heptachlor epoxide, γ-HCH, and dieldrin were detected in blood from all locations surveyed. Aldrin was not detected in any of the samples analyzed, probably due to its conversion to dieldrin. The levels of total organochlorine burden detected were higher in the blood from people in the irrigated cotton schemes (mean 261 ng ml(-1), range 38-641 ng ml(-1)) than in the blood of people from the irrigated sugarcane schemes (mean 204 ng ml(-1), range 59-365 ng ml(-1)). The highest levels of heptachlor epoxide (170 ng ml(-1)) and γ-HCH (92 ng ml(-1)) were observed in blood samples from Hasaheesa, while the highest levels of DDE (618 ng ml(-1)) and dieldrin (82 ng ml(-1)) were observed in blood samples from Wad Medani and Kenana, respectively. The organochlorine levels in blood samples seemed to decrease with increasing distance from the old irrigated cotton schemes (Wad Medani, Hasaheesa, and Elmanagil) where the heavy application of these pesticides took place historically.
Añez, Germán; Heisey, Daniel A. R.; Chancey, Caren; Fares, Rafaelle C. G.; Espina, Luz M.; Souza, Kátia P. R.; Teixeira-Carvalho, Andréa; Krysztof, David E.; Foster, Gregory A.; Stramer, Susan L.; Rios, Maria
2016-01-01
Background Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Methods We used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples was determined by culture in mosquito cells. Results DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log10 PCR-detectable units/ml. Conclusions DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma. PMID:26871560
Anez, German; Heisey, Daniel A. R.; Chancey, Caren; ...
2016-02-12
Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Here, we used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples wasmore » determined by culture in mosquito cells. As a result, DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log 10 PCR-detectable units/ml. In conclusion, DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anez, German; Heisey, Daniel A. R.; Chancey, Caren
Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Here, we used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples wasmore » determined by culture in mosquito cells. As a result, DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log 10 PCR-detectable units/ml. In conclusion, DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma.« less
De la Salle, Barbara
2017-02-15
The complete blood count (CBC) is one of the most frequently requested tests in laboratory medicine, performed in a range of healthcare situations. The provision of an ideal assay material for external quality assessment is confounded by the fragility of the cellular components of blood, the lack of commutability of stabilised whole blood material and the lack of certified reference materials and methods to which CBC results can be traced. The choice of assay material between fresh blood, extended life assay material and fully stabilised, commercially prepared, whole blood material depends upon the scope and objectives of the EQA scheme. The introduction of new technologies in blood counting and the wider clinical application of parameters from the extended CBC will bring additional challenges for the EQA provider.
Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C
2015-12-01
Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.
Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J
2017-07-01
To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged <8 years, 83% of those aged 9-18 years and 73% of those aged >18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.
Seibel, J; Bodié, K; Weber, S; Bury, D; Kron, M; Blaich, G
2010-10-01
The investigation of clinical pathology parameters (haematology, clinical chemistry and coagulation) is an important part of the preclinical evaluation of drug safety. However, the blood sampling method employed should avoid or minimize stress and injury in laboratory animals. In the present study, we compared the clinical pathology results from blood samples collected terminally from the vena cava (VC) immediately before necropsy with samples taken from the sublingual vein (VS) also prior to necropsy in order to determine whether the sampling method has an influence on clinical pathology parameters. Forty-six 12-week-old male Sprague-Dawley rats were assigned to two groups (VC or VS; n = 23 each). All rats were anaesthetized with isoflurane prior to sampling. In the VC group, blood was withdrawn from the inferior VC. For VS sampling, the tongue was gently pulled out and the VS was punctured. The haematology, coagulation and clinical chemistry parameters were compared. Equivalence was established for 13 parameters, such as mean corpuscular volume, white blood cells and calcium. No equivalence was found for the remaining 26 parameters, although they were considered to be similar when compared with the historical data and normal ranges. The most conspicuous finding was that activated prothrombin time was 30.3% less in blood taken from the VC (16.6 ± 0.89 s) than that in the VS samples (23.8 ± 1.58 s). Summing up, blood sampling from the inferior VC prior to necropsy appears to be a suitable and reliable method for terminal blood sampling that reduces stress and injury to laboratory rats in preclinical drug safety studies.
George, Elizabeth; Lai, Mei I; Teh, Lai Kuan; Ramasamy, Rajesh; Goh, Ern Huei; Asokan, Kamalan; Tan, J A M A; Vasudevan, Maithili; Low, Sharon
2011-12-01
Detection and quantification of Hb subtypes of human blood is integral to presumptive identification of thalassaemias. It has been used in neonatal screening of thalassaemia and Hb variants. The use of discarded red blood cells following processing of the cord blood for stem cells provides readily available diagnostic material for thalassaemia screening. In this study, we determined the range of Hb subtypes in 195 consecutive cord blood samples collected for cord blood banking. The 'cord blood samples' analysed were those of the remaining red blood cells after the cord blood was processed for stem cell storage. Quantification of Hb subtypes by high performance liquid chromatography (HPLC) was done on BioRad Variant II Hb testing system. Only 73 (36.5%) of the samples could be analyzed neat without dilution. With a 1:300 dilution with wash solution the acceptable area as recommended by the manufacturer for reading of a C-gram within the 1 to 3 million ranges were achieved in all. Eighteen (9%) 12 showed classical Hb Barts (y4) prerun peaks were confirmed by Sebia Hydrasys automated Hb gel electrophoresis and quantified by Sebia Capillarys 2 capillary electrophoresis. Only 1 (0.5%) was presumptively identified with HbH disease. Due to the limited number of samples no beta-thalassaemia major, Hb E beta-thalassaemia and Hb Barts hydrops fetalis were found. The HPLC assay was possible at a cost US$ 5 per sample and a turnover time of 10 samples per hour without technical difficulties. This study reports an effective and valuable protocol for thalassaemia screening in red blood cells which would otherwise be discarded during cord blood processing. Cord blood with severe and intermediate forms of thalassaemia can be preselected and not stored.
A method for estimating radioactive cesium concentrations in cattle blood using urine samples.
Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji
2017-12-01
In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.
de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa
2003-07-01
We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.
Sarkodie, Francis; Owusu-Dabo, Ellis; Hassall, Oliver; Bates, Imelda; Bygbjerg, Ib C; Ullum, Henrik
2016-09-01
To describe the recalled medical history, clinical manifestations, and treatment of yaws and syphilis by syphilis seroreactive blood donors in Kumasi, Ghana. Of the blood donors at Komfo Anokye Teaching Hospital, Kumasi, Ghana tested with the syphilis rapid diagnostic test (RDT) and later by rapid plasma reagin (RPR) test, 526 were seroreactive. Four hundred and seventy-one (89.5%) of these subjects were confirmed with the Ortho-Vitros Syphilis TP test as the gold standard and were interviewed to determine past or present clinical manifestations of yaws and syphilis. Of the 471 respondent donors, 28 (5.9%) gave a history of skin lesions and sores; four (14.3%) of these subjects, who were all male and RPR-positive, recalled a diagnosis of syphilis. All four reported having had skin lesions/bumps with slow-healing sores, but only one of them had had these symptoms before the age of 15 years. A small proportion of confirmed seroreactive donors in this sample had any recall of symptoms or treatment for yaws or syphilis. These data suggest that clinical questioning adds little further information to the current screening algorithm. The relative contribution of yaws and syphilis to frequent positive tests in endemic areas remains speculative. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Molecular Detection of Bartonella Species in Blood-Feeding Bat Flies from Mexico.
Moskaluk, Alexandra E; Stuckey, Matthew J; Jaffe, David A; Kasten, Rickie W; Aguilar-Setién, Alvaro; Olave-Leyva, José Ignacio; Galvez-Romero, Guillermo; Obregón-Morales, Cirani; Salas-Rojas, Mónica; García-Flores, María Martha; Aréchiga-Ceballos, Nidia; García-Baltazar, Anahí; Chomel, Bruno B
2018-05-01
Bartonellae are emerging blood-borne bacteria that have been recovered from a wide range of mammalian species and arthropod vectors around the world. Bats are now recognized as a potential wildlife reservoir for a diverse number of Bartonella species, including the zoonotic Candidatus B. mayotimonensis. These bat-borne Bartonella species have also been detected in the obligate ectoparasites of bats, such as blood-feeding flies, which could transmit these bacteria within bat populations. To better understand this potential for transmission, we investigated the relatedness between Bartonella detected or isolated from bat hosts sampled in Mexico and their ectoparasites. Bartonella spp. were identified in bat flies collected on two bat species, with the highest prevalence in Trichobius parasiticus and Strebla wiedemanni collected from common vampire bats (Desmodus rotundus). When comparing Bartonella sequences from a fragment of the citrate synthase gene (gltA), vector-associated strains were diverse and generally close to, but distinct from, those recovered from their bacteremic bat hosts in Mexico. Complete Bartonella sequence concordance was observed in only one bat-vector pair. The diversity of Bartonella strains in bat flies reflects the frequent host switch by bat flies, as they usually do not live permanently on their bat host. It may also suggest a possible endosymbiotic relationship with these vectors for some of the Bartonella species carried by bat flies, whereas others could have a mammalian host.
Alcaide, F; Carratala, J; Liñares, J; Gudiol, F; Martin, R
1996-01-01
From January 1988 to December 1994, 66 consecutive blood culture isolates of viridans group streptococci collected from febrile neutropenic cancer patients were tested for antimicrobial susceptibilities by the agar dilution method. The antibiotics studied were erythromycin, clarithromycin, roxithromycin, dirithromycin, azithromycin, josamycin, diacetyl-midecamycin, spiramycin, and quinupristin-dalfopristin. A total of 26 (39.4%) strains were resistant to erythromycin with an MIC range of 0.5 to > 128 micrograms/ml. The strains were classified into three groups according to their penicillin susceptibility: 42 (63.6%) were susceptible, 8 (12.1%) were intermediately resistant, and 16 (24.3%) were highly resistant. The percentages of erythromycin-resistant strains in each group were 23.8, 62.5, and 68.8%, respectively. Streptococcus mitis was the species most frequently isolated (83.3%) and showed the highest rates of penicillin (40%) and erythromycin (43.6%) resistance. MICs of all macrolide antibiotics tested and of quinupristin-dalfopristin were higher for penicillin-resistant strains than for penicillin-susceptible strains. All macrolide antibiotics tested had cross-resistance to erythromycin, which was not observed with quinupristin-dalfopristin. Our study shows a high rate of macrolide resistance among viridans group streptococci isolated from blood samples of neutropenic cancer patients, especially those infected with penicillin-resistant strains. These findings make macrolides unsuitable prophylactic agents against viridans group streptococcal bacteremia in this patient population. PMID:8878591
DIELECTROPHORESIS-BASED MICROFLUIDIC SEPARATION AND DETECTION SYSTEMS
Yang, Jun; Vykoukal, Jody; Noshari, Jamileh; Becker, Frederick; Gascoyne, Peter; Krulevitch, Peter; Fuller, Chris; Ackler, Harold; Hamilton, Julie; Boser, Bernhard; Eldredge, Adam; Hitchens, Duncan; Andrews, Craig
2009-01-01
Diagnosis and treatment of human diseases frequently requires isolation and detection of certain cell types from a complex mixture. Compared with traditional separation and detection techniques, microfluidic approaches promise to yield easy-to-use diagnostic instruments tolerant of a wide range of operating environments and capable of accomplishing automated analyses. These approaches will enable diagnostic advances to be disseminated from sophisticated clinical laboratories to the point-of-care. Applications will include the separation and differential analysis of blood cell subpopulations for host-based detection of blood cell changes caused by disease, infection, or exposure to toxins, and the separation and analysis of surface-sensitized, custom dielectric beads for chemical, biological, and biomolecular targets. Here we report a new particle separation and analysis microsystem that uses dielectrophoretic field-flow fractionation (DEP-FFF). The system consists of a microfluidic chip with integrated sample injector, a DEP-FFF separator, and an AC impedance sensor. We show the design of a miniaturized impedance sensor integrated circuit (IC) with improved sensitivity, a new packaging approach for micro-flumes that features a slide-together compression package and novel microfluidic interconnects, and the design, control, integration and packaging of a fieldable prototype. Illustrative applications will be shown, including the separation of different sized beads and different cell types, blood cell differential analysis, and impedance sensing results for beads, spores and cells. PMID:22025905
Michałowski, Jarosław M; Droździel, Dawid; Matuszewski, Jacek; Koziejowski, Wojtek; Jednoróg, Katarzyna; Marchewka, Artur
2017-08-01
Emotionally charged pictorial materials are frequently used in phobia research, but no existing standardized picture database is dedicated to the study of different phobias. The present work describes the results of two independent studies through which we sought to develop and validate this type of database-a Set of Fear Inducing Pictures (SFIP). In Study 1, 270 fear-relevant and 130 neutral stimuli were rated for fear, arousal, and valence by four groups of participants; small-animal (N = 34), blood/injection (N = 26), social-fearful (N = 35), and nonfearful participants (N = 22). The results from Study 1 were employed to develop the final version of the SFIP, which includes fear-relevant images of social exposure (N = 40), blood/injection (N = 80), spiders/bugs (N = 80), and angry faces (N = 30), as well as 726 neutral photographs. In Study 2, we aimed to validate the SFIP in a sample of spider, blood/injection, social-fearful, and control individuals (N = 66). The fear-relevant images were rated as being more unpleasant and led to greater fear and arousal in fearful than in nonfearful individuals. The fear images differentiated between the three fear groups in the expected directions. Overall, the present findings provide evidence for the high validity of the SFIP and confirm that the set may be successfully used in phobia research.
Historical exposure to inorganic mercury at the smelter works of Abbadia San Salvatore, Italy.
Bellander, T; Merler, E; Ceccarelli, F; Boffetta, P
1998-02-01
Metallic mercury production from cinnabar ore may result in high exposures to inorganic mercury, that are difficult to assess separately from the exposures originating from underground extraction, and previously have only been scantily described. We retrieved and analysed the air and biological mercury determinations on workers involved in the smelting process of the Abbadia San Salvatore mine (Monte Amiata, Italy). Native mercury was not present in the ore, and the exposure in the underground extraction was low. The smelter operated from 1897 to 1983. Blood and urine (24/h urine collections and concentration samples) had been sampled in 1968 to 1982, and analysed for mercury by atomic absorption spectrophotometry, and relate to all subjects. Exposure to mercury in air had been determined in a small set of personal samples in 1982. The data relate to all jobs in the smelter process, and all jobs entailed substantial exposure to mercury. The overall distribution of breathing zone air, blood and urinary levels is right-skewed and similar to the log-normal distribution (air, median 48 micrograms/m3, n = 49; blood, arithmetic mean AM 49 micrograms/L; geometric mean GM 26 micrograms/L, n = 192; urinary excretion, AM 140 micrograms/24 h, GM 78 micrograms/24 h, n = 839; and urinary concentration, AM 160 micrograms/L, GM 83 micrograms/L, n = 632). Air, blood and urinary values show a high ratio of the between- and within-job variance, indicating differences in exposure by job. Cinnabar pigment production, of which the exposure has not been characterised previously, was the job with the highest air (AM 160 micrograms/m3) and urinary levels (excretion AM 690 micrograms/24 h; concentration AM 1100 micrograms/L). Other jobs with high urinary levels were soot purification, laboratory work, and bottling. Cleaning of condensers showed the highest blood level (AM 280 micrograms/L). There is a downwards time trend in mercury concentration in blood and in urine. The corresponding trend is not seen for urinary excretion levels, the reason for this being unclear. Roasters, which is the most frequently monitored group, show however a decreasing trend in all sets of data (e.g. the mean of urinary excretion decreased from 300 micrograms/24 h in 1968/69 to 50 micrograms/24 h in 1980/81). The mercury exposure experienced by the smelters of Abbadia San Salvatore is in line with the few available data on workers from other mercury mines and smelters, and our data confirm the high exposure levels in this occupational group, in particular at cinnabar pigment production, soot purification, and condenser cleaning.
[The effect of work-related stress on the occurrence of increased blood pressure].
Budaj, A; Cybulski, J; Kułakowski, P; Makowska, E; Rezler, J; Lange, J; Gorzkowska, J; Abramowski, S
In 546 officials the arterial blood pressure was measured twice at the beginning and at the end of a working day, filling also an inquiry form. As hypertension systolic BP over 160 mm Hg (21.3 kPa) or more, and diastolic BP 96 mm Hg (12.7 kPa) or more were accepted. In 90 subjects (16.5%) above normal pressure values were found. Hypertension had been diagnosed previously in 50 subjects in this group (55.5%) but only 13 of them (26%) were treated systematically. Excessive stress of work was complained of by 62.6% of the subjects. Increased blood pressure was found significantly more frequently in the group perceiving excessive stress of work (19.9%) as compared to those not experiencing this stress (10.8%, p less than 0.1). In the group in managerial posts these proportions were 24.8% and 14.4% respectively (p less than 0.1). Blood pressure rise to abnormal levels during the working day occurred also significantly more frequently in the group experiencing it this was noted only in 1.6% of cases (p less than 0.5). The knowledge of own hypertension was very low in this group. These results indicate the necessity of increasing prophylactic measures in the form of greater frequency of control measurements of the blood pressure, better health education, and limitation of stress situations in working environment.
NASA Astrophysics Data System (ADS)
Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham
2011-09-01
A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.
[A fatal case series of Rocky Mountain spotted fever in Sonora, México].
Delgado-De la Mora, Jesús; Licona-Enríquez, Jesús David; Leyva-Gastélum, Marcia; Delgado-De la Mora, David; Rascón-Alcantar, Adela; Álvarez-Hernández, Gerardo
2018-03-15
Rocky Mountain spotted fever is a highly lethal infectious disease, particularly if specific treatment with doxycycline is given belatedly. To describe the clinical profile of fatal Rocky Mountain spotted fever cases in hospitalized patients in the state of Sonora, México. We conducted a cross-sectional study on a series of 47 deaths caused by Rickettsia rickettsii from 2013 to 2016. The diagnosis of Rocky Mountain spotted fever was confirmed in a single blood sample by polymerase chain reaction (PCR) or by a four-fold increase in immunoglobulin G measured in paired samples analyzed by indirect immunofluorescence. Clinical and laboratory characteristics were compared stratifying subjects into two groups: pediatric and adult. There were no differences in clinical characteristics between groups; petechial rash was the most frequent sign (96%), followed by headache (70%) and myalgia (67%). Although that doxycycline was administered before the fifth day from the onset of symptoms, death occurred in 55% of patients. In clinical laboratory, thrombocytopenia, and biomarkers of liver acute failure and acute kidney failure were the most frequent. Rocky Mountain spotted fever remains as one of the most lethal infectious diseases, which may be related not only to the lack of diagnostic suspicion and delayed administration of doxycycline, but to genotypic characteristics of Rickettsia rickettsii that may play a role in the variability of the fatality rate that has been reported in other geographical regions where the disease is endemic.
Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear.
Hassanpour, Gholamreza; Mirhendi, Hossein; Mohebali, Mehdi; Raeisi, Ahmad; Zeraati, Hojjat; Keshavarz, Hossein
2016-01-01
We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan- Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. A single primer/probe set for pan-species Plasmodium -specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum . All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples.
Peiffer-Smadja, Nathan; Ouedraogo, Ramatou; D'Ortenzio, Eric; Cissé, Papa Ndiaga; Zeggani, Zahra; Beavogui, Abdoul Habib; Faye, Sylvain Landry; Le Marcis, Frédéric; Yazdanpanah, Yazdan; Nguyen, Vinh-Kim
2017-05-02
There are few data on the acceptability of vaccination or blood sampling during Ramadan fasting month in Muslim countries. This could impact vaccination campaigns, clinical trials or healthcare during Ramadan. Using a semi-structured questionnaire, we conducted a cross-sectional study on 201 practising Muslims and 10 religious leaders in Conakry, Guinea in the wake of the recent epidemic Ebola epidemic. Acceptability of vaccination and blood sampling during Ramadan were investigated as well as reasons for refusal. Vaccination was judged acceptable during Ramadan by 46% (93/201, 95% CI 0.40-0.53) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.11). Blood sampling was judged acceptable during Ramadan by 54% (108/201, 95% CI 0.47-0.60) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.19). The percentage of participants that judged both blood sampling and vaccination acceptable during Ramadan was 40% (81/201, 95% CI 0.34-0.47) for practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) for religious leaders (p=0.048). The most common reasons for refusal of vaccination or blood sampling were that nothing should enter or leave the body during Ramadan (43%), that adverse events could lead to breaking the fast (32%), that blood should not be seen during Ramadan (9%) and that the Quran explicitly forbids it (9%). Although most Muslims leaders and scientists consider that injections including immunization and blood sampling should be authorized during Ramadan, many Muslims in our study judged vaccination or blood sampling unacceptable when fasting. Widely available recommendations on healthcare during Ramadan would be useful to inform Muslims. Copyright © 2017. Published by Elsevier Ltd.
Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien
2015-02-17
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
Jacobs, V R; Niemeyer, M; Gottschalk, N; Schneider, K T; Kiechle, M
2005-12-01
Private umbilical cord blood (UCB) banking after delivery has increased over the last decade. For adult/somatic stem cell research UCB is an essential source of stem cells and researchers question if the number of UCB samples for research might be reduced by private banking. A survey among seven private blood banks in Germany and analysis and comparison of the number of UCB samples donated for research within the STEMMAT project with private blood banking were performed from 03/2003 to 06/2005 at the Frauenklinik (OB/GYN), Technical University Munich, Germany. Within 27.5 months 1,551 UCB samples were collected for research purposes; the effective recruitment rate was higher than expectations at an effective 66.2 %. Private UCB banking [n = 24] was distributed among three cord blood banks [n = 16, 6 and 4]. The rate of private blood banking was 0.99 % for all deliveries, thus reducing the effective rate for research purpose by only 1.5 %. Under the assumption of active and successful recruitment of scientific UCB samples, private blood banking does not significantly reduce this rate and therefore is a negligible rival in the competition for sufficient numbers of UCB samples for research.
Inflammatory bowel disease exacerbation associated with Epstein-Barr virus infection.
Dimitroulia, Evangelia; Pitiriga, Vassiliki C; Piperaki, Evangelia-Theophano; Spanakis, Nicholas E; Tsakris, Athanassios
2013-03-01
Epstein-Barr virus infection is associated with inflammatory bowel disease, but its role as a pathogenetic or exacerbating factor remains unclear. The aim of this study was to evaluate the association between Epstein-Barr virus infection and inflammatory bowel disease, particularly in regard to exacerbation of disease activity. This was a nonrandomized crosssectional study in subgroups of patients with inflammatory bowel disease compared with a control group with noninflammatory disease. Participants were patients treated for ulcerative colitis or Crohn's disease and individuals undergoing evaluation for noninflammatory disease recruited from 2 urban adult gastrointestinal referral centers in Greece. Diagnosis of inflammatory bowel disease was based on standard clinical and endoscopic criteria. Demographic and clinical characteristics of all participants were recorded. Whole blood samples and fresh tissue samples from biopsy of intestinal sites were obtained from each participant. The presence of Epstein-Barr virus was determined by amplifying the LMP1 gene of the virus in blood and intestinal tissue samples. The study comprised 94 patients with inflammatory bowel disease (63 with ulcerative colitis and 31 with Crohn's disease) and 45 controls with noninflammatory disease. Of the 94 patients, 67 (71.3%) had disease exacerbation and 27 (28.7%) were in remission. The prevalence of Epstein-Barr virus genome was significantly higher in patients than in controls for intestinal tissue (44 patients, 46.8% vs 6 controls, 13.3%; p = 0.001), but not for whole blood (24 patients, 25.5% vs 9 controls, 20%; p = 0.3). The viral genome was found significantly more frequently in intestinal samples from patients with disease exacerbation compared with patients in remission (38 patients with exacerbation, 56.7% vs 6 patients in remission, 22.2%; p = 0.001), but no significant difference was found for whole blood (18 patients with exacerbation, 26.8% vs 6 patients in remission, 22.2%; p = 0.79). Neither disease exacerbation nor the presence of virus genome was related to demographic or clinical characteristics. The exact location of Epstein-Barr virus in the intestinal tissues could not be specified because morphological data by immunohistochemistry or in situ hybridization were not available. Although causality could not be determined, the significantly higher prevalence of Epstein-Barr virus in intestinal tissue from patients with inflammatory bowel disease compared with controls and in patients with exacerbation compared with patients in remission suggests a potential viral involvement in the severity of inflammatory bowel disease. These findings merit further investigation in view of a potential for usefulness of antiviral therapy against Epstein-Barr virus infection in patients with exacerbation of inflammatory bowel disease.
Ruzauskas, Modestas; Siugzdiniene, Rita; Klimiene, Irena; Virgailis, Marius; Mockeliunas, Raimundas; Vaskeviciute, Lina; Zienius, Dainius
2014-11-28
Among coagulase-negative staphylococci, Staphylococcus haemolyticus is the second most frequently isolated species from human blood cultures and has the highest level of antimicrobial resistance. This species has zoonotic character and is prevalent both in humans and animals. Recent studies have indicated that methicillin-resistant S. haemolyticus (MRSH) is one of the most frequent isolated Staphylococcus species among neonates in intensive care units. The aim of this study was to determine the presence of MRSH in different groups of companion animals and to characterize isolates according their antimicrobial resistance. Samples (n = 754) were collected from healthy and diseased dogs and cats, female dogs in pure-breed kennels, healthy horses, and kennel owners. Classical microbiological tests along with molecular testing including PCR and 16S rRNA sequencing were performed to identify MRSH. Clonality of the isolates was assessed by Pulsed Field Gel Electrophoresis using the SmaI restriction enzyme. Antimicrobial susceptibility testing was performed using the broth micro-dilution method. Detection of genes encoding antimicrobial resistance was performed by PCR. Statistical analysis was performed using the R Project of Statistical Computing, "R 1.8.1" package. From a total of 754 samples tested, 12 MRSH isolates were obtained. No MRSH were found in horses and cats. Eleven isolates were obtained from dogs and one from a kennel owner. Ten of the dog isolates were detected in pure-breed kennels. The isolates demonstrated the same clonality only within separate kennels.The most frequent resistances of MRSH isolates was demonstrated to benzylpenicillin (91.7%), erythromycin (91.7%), gentamicin (75.0%), tetracycline (66.7%), fluoroquinolones (41.7%) and co-trimoxazole (41.7%). One isolate was resistant to streptogramins. All isolates were susceptible to daptomycin, rifampin, linezolid and vancomycin. The clone isolated from the kennel owner and one of the dogs was resistant to beta-lactams, macrolides, gentamicin and tetracycline. Pure-breed kennels keeping 6 or more females were determined to be a risk factor for the presence of MRSH strains. MRSH isolated from companion animals were frequently resistant to some classes of critically important antimicrobials, although they remain susceptible to antibiotics used exclusively in human medicine.
Agglutination reactions of human leucocytes
Schulz, Jeanette; Muller, Helga
1963-01-01
Agglutination tests with various sera and leucocytes from 58 leukaemic patients and 61 patients without leukaemia are reported. The agglutination of white blood cells by guinea-pig serum is of limited value in the diagnosis of leukaemia, though the test may be helpful in distinguishing leukaemia from other lymphomatous disorders. Leuco-autoagglutinins were demonstrated more frequently than expected. Eleven leukaemic and six non-leukaemic sera agglutinated autologous leucocytes. White blood cell agglutinins showed no apparent relationship to maturity or numbers of circulating leucocytes or to previous blood transfusions, x-irradiation, or therapy with antimetabolites. PMID:14044034
2011-06-27
study will incorporate new phlebotomy procedures that will reduce the potential for clotting and hemolysis in the blood . The increase of RDW in the...observed blood clotting or hemolysis (≤ 5% of data), which can frequently result in anomalous hematological and/or serum chemistry values, anomalous...exposure concentrations were identified for both males and females, including: (1) increased red blood cell distribution width (RDW) in rats from the
Zou, Ping; Dennis, Cindy-Lee; Lee, Ruth; Parry, Monica
2017-01-01
Responding to high prevalence of hypertension and patients’ preference of integrating traditional Chinese medicine for blood pressure control, the Dietary Approach to Stop Hypertension With Sodium Reduction for Chinese Canadian (DASHNa-CC) intervention was newly designed as a culturally sensitive dietary educational intervention to facilitate middle-aged and senior Chinese Canadians’ blood pressure control in community. The aim of this study was to report the hypertension prevalence rate according to the data from blood pressure screening events, to describe the characteristics of health service utilization among aged Chinese Canadians, and to report the evaluation of participant satisfaction to the DASHNa-CC intervention. This study was designed as a pilot randomized controlled trial with a sample size of 60. Among 618 Chinese Canadians participated in blood pressure screening events, 54.5% (n = 337) having various levels of hypertension. Across 2 months, 38 (63.3%) participants made a total of 47 visits to see their family physicians; 20 (33.3%) participants consulted their family members 224 times for lifestyle modifications and hypertension self-management. Various forms of Chinese media were frequently used as sources of health care information, and English media were rarely accessed. Participants highly satisfied with the contents, delivery approaches, and integration of traditional Chinese medicine in the intervention. Results indicated that middle-aged and senior Chinese Canadians have high hypertension prevalence and specific characteristics of health service utilization. It is important to implement interventions, which are culturally tailored, language appropriate, using proper technology and incorporating traditional Chinese medicine, in Chinese Canadian community for hypertension control. PMID:28853303
Acute and chronic alcohol use correlated with methods of suicide in a Swiss national sample.
Pfeifer, P; Bartsch, C; Hemmer, A; Reisch, T
2017-09-01
Chronic and acute alcohol use are highly associated risk factors for suicides worldwide. Therefore, we examined suicide cases with and without alcohol use disorder (AUD) using data from the SNSF project "Suicide in Switzerland: A detailed national survey". Our investigations focus on correlations between acute and chronic alcohol use with reference to suicide and potential interactions with the methods of suicide. We used data from the SNSF project in which all cases of registered completed suicide in Switzerland reported to any of the seven Swiss institutes of legal and forensic medicine between 2000 and 2010 were collected. We extracted cases that were tested for blood alcohol to use in our analysis. We compared clinical characteristics, blood alcohol concentrations, and methods of suicide in cases with and without AUD. Out of 6497 cases, 2946 subjects were tested for acute alcohol use and included in our analysis. Of the latter, 366 (12.4%) persons had a medical history of AUD. Subjects with AUD significantly had higher blood alcohol concentrations and were more often in medical treatment before suicide. Drug intoxication as method of suicide was more frequent in cases with AUD compared to NAUD. Overall, we found a high incidence of acute alcohol use at the time of death in chronic alcohol misusers (AUD). The five methods of suicide most commonly used in Switzerland differed considerably between individuals with and without AUD. Blood alcohol concentrations varied across different methods of suicide independently from the medical history in both groups. Copyright © 2017 Elsevier B.V. All rights reserved.
Morphological aspects of myocardial bridges.
Lujinović, Almira; Kulenović, Amela; Kapur, Eldan; Gojak, Refet
2013-11-01
Although some myocardial bridges can be asymptomatic, their presence often causes coronary disease either through direct compression of the "tunnel" segment or through stimulation and accelerated development of atherosclerosis in the segment proximally to the myocardial bridge. The studied material contained 30 human hearts received from the Department of Anatomy. The hearts were preserved 3 to 5 days in 10% formalin solution. Thereafter, the fatty tissue was removed and arterial blood vessels prepared by careful dissection with special reference to the presence of the myocardial bridges. Length and thickness of the bridges were measured by the precise electronic caliper. The angle between the myocardial bridge fibre axis and other axis of the crossed blood vessel was measured by a goniometer. The presence of the bridges was confirmed in 53.33% of the researched material, most frequently (43.33%) above the anterior interventricular branch. The mean length of the bridges was 14.64 ± 9.03 mm and the mean thickness was 1.23 ± 1.32 mm. Myocardial bridge fibres pass over the descending blood vessel at the angle of 10-90 degrees. The results obtained on a limited sample suggest that the muscular index of myocardial bridge is the highest for bridges located on RIA, but that the difference is not significant in relation to bridges located on other branches. The results obtained suggest that bridges located on other branches, not only those on RIA, could have a great contractive power and, consequently, a great compressive force, which would be exerted on the wall of a crossed blood vessel.
Light scattering method to measure red blood cell aggregation during incubation
NASA Astrophysics Data System (ADS)
Grzegorzewski, B.; Szołna-Chodór, A.; Baryła, J.; DreŻek, D.
2018-01-01
Red blood cell (RBC) aggregation can be observed both in vivo as well as in vitro. This process is a cause of alterations of blood flow in microvascular network. Enhanced RBC aggregation makes oxygen and nutrients delivery difficult. Measurements of RBC aggregation usually give a description of the process for a sample where the state of a solution and cells is well-defined and the system reached an equilibrium. Incubation of RBCs in various solutions is frequently used to study the effects of the solutions on the RBC aggregation. The aggregation parameters are compared before and after incubation while the detailed changes of the parameters during incubation remain unknown. In this paper we have proposed a method to measure red blood cell aggregation during incubation based on the well-known technique where backscattered light is used to assess the parameters of the RBC aggregation. Couette system consisting of two cylinders is adopted in the method. The incubation is observed in the Couette system. In the proposed method following sequence of rotations is adapted. Two minutes rotation is followed by two minutes stop. In this way we have obtained a time series of back scattered intensity consisting of signals respective for disaggregation and aggregation. It is shown that the temporal changes of the intensity manifest changes of RBC aggregation during incubation. To show the ability of the method to assess the effect of incubation time on RBC aggregation the results are shown for solutions that cause an increase of RBC aggregation as well as for the case where the aggregation is decreased.
Modeling laser speckle imaging of perfusion in the skin (Conference Presentation)
NASA Astrophysics Data System (ADS)
Regan, Caitlin; Hayakawa, Carole K.; Choi, Bernard
2016-02-01
Laser speckle imaging (LSI) enables visualization of relative blood flow and perfusion in the skin. It is frequently applied to monitor treatment of vascular malformations such as port wine stain birthmarks, and measure changes in perfusion due to peripheral vascular disease. We developed a computational Monte Carlo simulation of laser speckle contrast imaging to quantify how tissue optical properties, blood vessel depths and speeds, and tissue perfusion affect speckle contrast values originating from coherent excitation. The simulated tissue geometry consisted of multiple layers to simulate the skin, or incorporated an inclusion such as a vessel or tumor at different depths. Our simulation used a 30x30mm uniform flat light source to optically excite the region of interest in our sample to better mimic wide-field imaging. We used our model to simulate how dynamically scattered photons from a buried blood vessel affect speckle contrast at different lateral distances (0-1mm) away from the vessel, and how these speckle contrast changes vary with depth (0-1mm) and flow speed (0-10mm/s). We applied the model to simulate perfusion in the skin, and observed how different optical properties, such as epidermal melanin concentration (1%-50%) affected speckle contrast. We simulated perfusion during a systolic forearm occlusion and found that contrast decreased by 35% (exposure time = 10ms). Monte Carlo simulations of laser speckle contrast give us a tool to quantify what regions of the skin are probed with laser speckle imaging, and measure how the tissue optical properties and blood flow affect the resulting images.
de Kort, Sandra W K; Willemsen, Ruben H; van der Kaay, Danielle C M; Hokken-Koelega, Anita C S
2009-07-01
We previously reported that short, small for gestational age (SGA) children who were born preterm have a lower body fat percentage and a higher blood pressure, insulin secretion and disposition index than short SGA children born at term. Whether preterm birth also influences these parameters during GH treatment is unknown. To compare blood pressure, insulin sensitivity, beta-cell function and body composition during 4 years of GH treatment, between preterm and term short SGA children. A total of 404 prepubertal non-GH-deficient short SGA children were divided into 143 preterm (< 36 weeks) and 261 term children. Height, blood pressure (n = 404), body composition measured by dual energy X-ray absorptiometry (DXA) (n = 138) and insulin sensitivity and beta-cell function calculated from a frequent sampling intravenous glucose tolerance test (FSIGT) with tolbutamide (n = 74) or from the homeostasis model assessment of insulin resistance (HOMA-IR) (n = 204). In preterm and term children, GH treatment resulted in a similar decrease in systolic and diastolic blood pressure, body fat percentage, limb fat/total fat ratio and insulin sensitivity, and a similar increase in insulin secretion and disposition index. Lean body mass (LBM) corrected for gender and height increased in term children and did not change in preterm children. Multiple regression analysis revealed that this difference in GH effect on LBM was not associated with gestational age. The effect of GH treatment on metabolic and cardiovascular risk factors is similar in preterm and term short, SGA children.
Zamengo, Luca; Frison, Giampietro; Tedeschi, Gianpaola; Frasson, Samuela
2016-08-01
Blood alcohol concentration is the most frequent analytical determination carried out in forensic toxicology laboratories worldwide. It is usually required to assess if an offence has been committed by comparing blood alcohol levels with specified legal limits, which can vary widely among countries. Due to possible serious legal consequences associated with non-compliant alcohol levels, measurement uncertainty should be carefully evaluated, along with other metrological aspects which can influence the final result. The whole procedure can be time-consuming and error-generating in routine practice, increasing the risks for unreliable assessments. A software application named Ethanol WorkBook (EtWB) was developed at the author's laboratory by using Visual Basic for Application language and MS Excel(®), with the aim of providing help to forensic analysts involved in blood alcohol determinations. The program can (i) calculate measurement uncertainties and decision limits with different methodologies; (ii) assess compliance to specification limits with a guard-band approach; (iii) manage quality control (QC) data and create control charts for QC samples; (iv) create control maps from real cases data archives; (v) provide laboratory reports with graphical outputs for elaborated data and (vi) create comprehensive searchable case archives. A typical example of drink driving case is presented and discussed to illustrate the importance of a metrological approach for reliable compliance assessment and to demonstrate software application in routine practice. The tool is made freely available to the scientific community at request. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Faraji, Reza; Behjati-Ardakani, Mostafa; Moshtaghioun, Seyed Mohammad; Kalantar, Seyed Mehdi; Namayandeh, Seyedeh Mahdieh; Soltani, Mohammadhossien; Emami, Mahmood; Zandi, Hengameh; Firoozabadi, Ali Dehghani; Kazeminasab, Mahmood; Ahmadi, Nastaran; Sarebanhassanabadi, Mohammadtaghi
2018-02-01
Broad-range bacterial rDNA polymerase chain reaction (PCR) followed by sequencing may be identified as the etiology of infective endocarditis (IE) from surgically removed valve tissue; therefore, we reviewed the value of molecular testing in identifying organisms' DNA in the studies conducted until 2016. We searched Google Scholar, Scopus, ScienceDirect, Cochrane, PubMed, and Medline electronic databases without any time limitations up to December 2016 for English studies reporting microorganisms involved in infective endocarditis microbiology using PCR and real-time PCR. Most studies were prospective. Eleven out of 12 studies used valve tissue samples and blood cultures while only 1 study used whole blood. Also, 10 studies used the molecular method of PCR while 2 studies used real-time PCR. Most studies used 16S rDNA gene as the target gene. The bacteria were identified as the most common microorganisms involved in infective endocarditis. Streptococcus spp. and Staphylococcus spp. were, by far, the most predominant bacteria detected. In all studies, PCR and real-time PCR identified more pathogens than blood and tissue cultures; moreover, the sensitivity and specificity of PCR and real-time PCR were more than cultures in most of the studies. The highest sensitivity and specificity were 96% and 100%, respectively. The gram positive bacteria were the most frequent cause of infective endocarditis. The molecular methods enjoy a greater sensitivity compared to the conventional blood culture methods; yet, they are applicable only to the valve tissue of the patients undergoing cardiac valve surgery. Copyright © 2017. Published by Elsevier Taiwan.
2012-04-26
ISS030-E-257690 (26 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares for IMMUNE venous blood sample draws in the Columbus laboratory of the International Space Station. Following the blood draws, the samples were temporarily stowed in the Minus Eighty Laboratory Freezer for ISS 1 (MELFI-1) and later packed together with saliva samples on the Soyuz TMA-22 for return to Earth for analysis.
In vitro production of GHB in blood and serum samples under various storage conditions.
Zörntlein, S W; Kopp, A; Becker, J; Kaufmann, T J; Röhrich, J; Urban, R
2012-01-10
The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly, with the consequence of winning valuable time for the potential victim, but only if serum is collected for GHB determination or if the whole blood sample is frozen immediately after collection and the procedure well documented. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Algorithm-based arterial blood sampling recognition increasing safety in point-of-care diagnostics.
Peter, Jörg; Klingert, Wilfried; Klingert, Kathrin; Thiel, Karolin; Wulff, Daniel; Königsrainer, Alfred; Rosenstiel, Wolfgang; Schenk, Martin
2017-08-04
To detect blood withdrawal for patients with arterial blood pressure monitoring to increase patient safety and provide better sample dating. Blood pressure information obtained from a patient monitor was fed as a real-time data stream to an experimental medical framework. This framework was connected to an analytical application which observes changes in systolic, diastolic and mean pressure to determine anomalies in the continuous data stream. Detection was based on an increased mean blood pressure caused by the closing of the withdrawal three-way tap and an absence of systolic and diastolic measurements during this manipulation. For evaluation of the proposed algorithm, measured data from animal studies in healthy pigs were used. Using this novel approach for processing real-time measurement data of arterial pressure monitoring, the exact time of blood withdrawal could be successfully detected retrospectively and in real-time. The algorithm was able to detect 422 of 434 (97%) blood withdrawals for blood gas analysis in the retrospective analysis of 7 study trials. Additionally, 64 sampling events for other procedures like laboratory and activated clotting time analyses were detected. The proposed algorithm achieved a sensitivity of 0.97, a precision of 0.96 and an F1 score of 0.97. Arterial blood pressure monitoring data can be used to perform an accurate identification of individual blood samplings in order to reduce sample mix-ups and thereby increase patient safety.
Madrona, Dalmiro Prados; Herrera, María Dolores Fernández; Jiménez, Dalmiro Prados; Giraldo, Sonsoles Gómez; Campos, Rita Robles
2014-01-01
Background Women seem more willing to donate blood than men despite the limitations that affect their donation rate. The aim of our study was to determine the role of women in altruistic donation of blood in Huelva, a province in south-western Spain. Materials and methods We registered 87,601 offers to donate whole blood between January 1st, 2005 and December 31st, 2009. We statistically analysed variables such as sex, age, offers, deferrals and donations, problems in venous access, vasovagal reactions, weight and blood pressure to establish their significance according to donor gender. Results With regards to gender, 52.3% of donors were women and 47.7% men. Of the 87,601 offers to donate blood, 46.5% were from females and 53.5% from males. More females than males made their first donation during the study period. However, 43.9 % of donations were from women, whereas 56.1% were from men. Overall 8.7% of offers were deferred, 62.7% of which due to a low haemoglobin concentration, which was the most frequent cause of deferral in women. Difficulties in venous access and vasovagal reactions were also more frequent in female donors than in male donors. By the end of the study period, donor fidelity was 58.6% for men and 48.6% for women. Discussion In the province of Huelva, women are more altruistically inclined than men to give blood, with the percentages of donors and first-time donors being higher among females. However, there are restrictions to women giving blood, especially low haemoglobin concentration, which reduce the number of female blood donations. Women also have more difficulty when blood is withdrawn and are more susceptible to vasovagal reactions, which negatively affect their experience as donors. Measures should be taken to reduce these barriers to encourage women to continue to offer to donate blood, thereby ensuring that they become regular donors, which is a key factor in guaranteeing an adequate supply of blood within the region of Andalusia. PMID:23245721
Liu, Jue; Zhang, Shikun; Wang, Qiaomei; Shen, Haiping; Zhang, Yiping; Liu, Min
2017-12-03
ABO and RhD blood groups are key factors affecting blood transfusion safety. The distribution of ABO and RhD blood groups varies globally, but limited data exist for ethnic distributions of these blood groups in Asian populations. We aimed to evaluate the distribution of ABO and RhD blood groups among Chinese ethnic groups. A population-based cross-sectional study. Data on ABO groups and ethnicities were obtained from the National Free Preconception Health Examination Project (NFPHEP) with participants from 220 counties of 31 provinces in China PARTICIPANTS: There were 3 832 034 participants aged 21-49 years who took part in the NFPHEP from January 2010 to December 2012 and were included in this study. The proportion of ABO and RhD blood groups among different ethnic groups was calculated. ABO and RhD blood distribution was significantly different among nine ethnic groups (P<0.001). Compared with other ethnic groups, the Yi group had more A phenotypes (34.0%), and the Manchu (33.7%) and Mongolian (33.3%) ethnic groups had more B phenotypes. The Zhuang group had the greatest proportion of O phenotypes (41.8%), followed by the Miao group (37.7%). AB phenotypes were more frequent in the Uygur ethnic group (10.6%) but lower in the Zhuang group (5.5%). Meanwhile, RhD negativity (RhD-) was greater in the Uygur group (3.3%) than in the Mongolian (0.3%) and Manchu ethnic groups (0.4%). O RhD- blood groups were more frequent in the Uygur group (0.8%) than in the other ethnic groups (0.1%-0.4%, P<0.001). ABO and RhD blood phenotypes vary across different ethnic groups in China. The diversity in the distribution of the ABO and RhD blood groups in different ethnic groups should be considered when developing rational and evidence-based strategies for blood collection and management. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Kim, Seoyoun; Ferraro, Kenneth F.
2014-01-01
Purpose of the Study: The study investigates whether productive activities by older adults reduce bodily inflammation, as indicated by C-reactive protein (CRP), a biomeasure associated with the risk of cardiovascular diseases. Design and Methods: The study uses a representative survey of adults aged 57–85 from the National Social Life, Health, and Aging Project (N = 1,790). Linear regression models were used to analyze the effects of multiple roles (employment, volunteering, attending meetings, and caregiving) and the frequency of activity within each role on log values of CRP concentration (mg/L) drawn from assayed blood samples. Results: Number of roles for productive activities was associated with lower levels of CRP net of chronic conditions, lifestyle factors, and socioeconomic resources. When specific types of activity were examined, volunteering manifested the strongest association with lower levels of inflammation, particularly in the 70+ group. There was no evidence that frequent engagement in volunteer activity was associated with heightened inflammation. Implications: Productive activities—and frequent volunteering in particular—may protect individuals from inflammation that is associated with increased risk of hypertension and cardiovascular disease. PMID:23969258
Current alcohol use is associated with a reduced risk of hot flashes in midlife women.
Schilling, Chrissy; Gallicchio, Lisa; Miller, Susan R; Babus, Janice K; Lewis, Lynn M; Zacur, Howard; Flaws, Jodi A
2005-01-01
To examine the relation between current alcohol use, estradiol, estrone, and testosterone levels, and hot flashes in midlife women using a case-control study design. Cases were midlife women (45-54 years) who reported ever experiencing hot flashes. Controls were midlife women (45-54 years) who reported never experiencing hot flashes. Each participant completed a questionnaire and provided a blood sample that was used to measure estradiol, estrone, and testosterone levels by enzyme-linked immunosorbent assay. The results indicate that current alcohol use (at least one day per month) was significantly associated with a reduced risk of hot flashes compared to non-use of alcohol, independent of age and smoking habits. The hot flashes experienced by current alcohol users were less severe and less frequent than those experienced by non-users of alcohol. Further, current alcohol users had similar levels of estradiol, estrone, and testosterone compared to non-users of alcohol. These data suggest that current alcohol use is associated with a reduced risk of any, severe, and frequent hot flashes in midlife women by a mechanism that may not include changes in sex steroid hormone levels.
Factors associated with personal protection equipment use and hand hygiene among hemodialysis staff.
Shimokura, Gayle; Weber, David J; Miller, William C; Wurtzel, Heather; Alter, Miriam J
2006-04-01
Because exposure to blood by health care workers is frequent during hemodialysis, gloves are required for all contact with patients and their equipment, followed by hand hygiene. In this study, we investigated factors associated with performing these practices as recommended. Staff members from a sample of 45 US hemodialysis facilities were surveyed using an anonymous self-administered questionnaire. Factors independently associated with reporting increased compliance with recommended hand hygiene and glove use practices during patient care were identified with multivariate modeling. Of 605 eligible staff members, 420 (69%) responded: registered nurses, 41%; dialysis technicians, 51%; and licensed practical nurses, 8%. Only 35% reported that dialysis patients were at risk for bloodborne virus infections, and only 36% reported always following recommended hand hygiene and glove use practices. Independent factors associated with more frequent compliance were being a technician (versus a registered nurse) and reporting always doing what was needed to protect themselves from infection. Compliance with recommended hand hygiene and glove use practices by hemodialysis staff was low. The rationale for infection control practices specific to the hemodialysis setting was poorly understood by all staff. Infection control training should be tailored to this setting and should address misconceptions.
[Mediterranean visceral leishmaniasis].
Marty, Pierre; Pomares, Christelle; Michel, Grégory; Delaunay, Pascal; Ferrua, Bernard; Rosenthal, Eric
2011-01-01
Mediterranean visceral leishmaniasis is a parasitic zoonosis due to Leishmania infantum. The dog is the reservoir species and also the main victim. The vector is the female Phlebotomus sand fly. In the southern Mediterranean region the disease is most frequent in children, whereas in Europe, and particularly in France, it is mostly an opportunistic infection associated with immunosuppression. Frequent asymptomatic carriage has been detected in southern Europe. The classic symptom triad consists of fever, pallor and splenomegaly. Biological signs include low cell blood counts (anemia, leukoneutropenia, and thrombocytopenia) and an inflammatory syndrome. Commercial serologic tests such as those based on immunoblotting are very useful. The gold standard for diagnosis is parasite detection in bone marrow or blood. PCR is useful for therapeutic follow-up. Treatment is currently based on liposomal amphotericin B (AmBisome).
Pasanisi, Eugenia; Cortés-Gómez, Adriana A; Pérez-López, Marcos; Soler, Francisco; Hernández-Moreno, David; Guerranti, Cristiana; Martellini, Tania; Fuentes-Mascorro, Gisela; Romero, Diego; Cincinelli, Alessandra
2016-12-01
Lepidochelys olivacea is the most abundant and globally distributed sea turtle species in the world and thus, monitoring this species for persistent organic pollutants, such as perfluorinated chemicals, is fundamental for their protection. This study was the first to evaluate the occurrence of five PFCAs (PFOA, PFNA, PFDA, PFUnA, PFDoA) in liver and blood samples of Olive Ridley turtle population from the Escobilla beach (Oaxaca, Mexico). PFDA and PFUnA were the predominant PFCs in blood samples (detected in 93% and 84% of samples, respectively) and were also present in the highest concentrations. Liver samples showed higher PFCA concentrations than whole blood samples, with PFNA and PFDA the most abundant PFCs congeners in liver samples, detected in 65% and 47% of the samples, respectively. The measured levels of contaminants in the blood samples of Lepidochelys olivacea sea turtles were compared to the levels reported in the literature for other turtle species. While linear significant correlations between PFNA, PFDA and PFUnA concentrations in blood samples and curved carapace lengths were determined, no correlation was found for PFOA, supporting the hypothesis that sea turtles could have a higher ability to eliminate this perfluorinated chemical from their blood than other PFCAs. However, we do not know if the concentrations are species or sampling areas dependent. Copyright © 2016 Elsevier B.V. All rights reserved.
Stability of carboxyhemoglobin in stored and mailed blood samples.
Hampson, Neil B
2008-02-01
Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.
Ernst, D; Clerc, J; Decullier, E; Gavanier, G; Dupuis, O
2012-10-01
At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; P<0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3-18.2]; P<0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians. Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Kennedy, Laura; Vass, J. Keith; Haggart, D. Ross; Moore, Steve; Burczynski, Michael E.; Crowther, Dan; Miele, Gino
2008-01-01
Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene™ RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2™ enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene™ blood samples also advocate a short, fixed room temperature storage time for all PAXgene™ blood samples collected for the purposes of global transcriptional profiling in clinical studies. PMID:19578521
[Nocturnal hypoxemia and arrhythmia in patients with chronic obstructive lung diseases (COLD)].
Skwarski, K
1989-05-01
A decrease in the arterial blood saturation by oxygen in patients with POChP is a frequent phenomenon. It is more serious in patients type blue boaters and less frequent among patients type pink puffers. The aim of the paper was to compare the arterial blood saturation by oxygen in the groups examined during two nights: during the first night the patients breathed atmospheric air whereas during the second night they were given oxygen. The author also studied the influence of oxygenation of an organism on the frequency of cardiac rhythm disorders (ZRS). The author examined a group of 20 patients with the predominance of chronic bronchitis--blue boaters (average VC was 1.95 l, FEV1--0.81 l, PaO2 while breathing atmospheric air 52 mm Hg and 68 mm Hg after giving oxygen, PaCO2 47 and 51 mm Hg respectively) and 20 patients with the predominance of emphysema--pink puffers (average VC--2.30 l, FEV1--0.86 l, PaO2 while breathing atmospheric air 60 mm Hg and 70 mm Hg after giving oxygen, PaCO2 39 and 40 mm respectively). It was found that the patients with heavy hypoxaemia and hypercapnia had worse arterial blood saturation by oxygen during the two nights of investigation in comparison with the other group. The author also found more frequent cardiac rhythm disorders in this group of patients. Giving oxygen improved blood oxygenation in the two groups and lowered the frequency of cardiac rhythm disorders. The results obtained indicate to the need of oxygen therapy in patients with advanced POChP, especially during the night so as to avoid nocturnal hypoxaemia of an organism.
Jin, Ling; Escher, Beate I; Limpus, Colin J; Gaus, Caroline
2015-11-01
Conventional target analysis of biological samples such as blood limits our ability to understand mixture effects of chemicals. This study aimed to establish a rapid passive sampling technique using the polymer polydimethylsiloxane (PDMS) for exhaustive extraction of mixtures of neutral organic chemicals accumulated in blood of green turtles, in preparation for screening in in vitro bioassays. We designed a PDMS-blood partitioning system based on the partition coefficients of chemicals between PDMS and major blood components. The sampling kinetics of hydrophobic test chemicals (polychlorinated dibenzo-p-dioxins; PCDDs) from blood into PDMS were reasonably fast reaching steady state in <96 h. The geometric mean of the measured PDMS-blood partition coefficients for PCDDs, polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) was 14 L blood kg PDMS(-1) and showed little variability (95% confidence interval from 8.4 to 29) across a wide range of hydrophobicity (logKow 5.7-8.3). The mass transfer of these chemicals from 5 mL blood into 0.94 g PDMS was 62-84%, which is similar to analytical recoveries in conventional solvent extraction methods. The validated method was applied to 15 blood samples from green turtles with known concentrations of PCDD/Fs, dioxin-like PCBs, PBDEs and organochlorine pesticides. The quantified chemicals explained most of the dioxin-like activity (69-98%), but less than 0.4% of the oxidative stress response. The results demonstrate the applicability of PDMS-based passive sampling to extract bioaccumulative chemicals from blood as well as the value of in vitro bioassays for capturing the combined effects of unknown and known chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique
2015-08-01
As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
Improving blood transfusion practice by regular education in the United Arab Emirates.
Sajwani, F H
2012-07-01
A cross-match to transfused unit ratio of less than 2.0 is frequently used to assess performance in many hospital blood banks. This brief report was initiated to evaluate the practice at a local hospital and to emphasize the importance of regular educational sessions to improve blood transfusion practice. Retrospective data on cross-match : transfused (C : T) ratio of all departments was collected and educational sessions were given to improve practice. Thereafter, a new set of data was collected and change in practice was assessed. Initial data showed total (C : T) ratio of 1.95. After medical staff education, analysis showed clinically significant improvement in blood utilization practice with a (C : T) ratio of 1.60. This brief report indicates the importance of regular physician education, the potential role of blood transfusion committee, and the need to implement clear guidelines for blood transfusion. © 2012 American Association of Blood Banks.
Aguado, Alba; López, Flora; Miravet, Sonia; Oriol, Pilar; Fuentes, M Isabel; Henares, Belén; Badia, Teresa; Esteve, Lluis; Peligro, Javier
2009-05-08
Information on hypertension in the very elderly is sparse. Until recently evidence of benefits from pharmacological treatment was inconclusive. We estimated the prevalence of hypertension in subjects aged 80 or more, the proportion of awareness, treatment and control. Explanatory variables associated with good control were also studied. Cross sectional, population-based study, conducted in Martorell, an urban Spanish municipality, in 2005. By simple random sampling from the census, 323 subjects aged 80 or more were included. Patients were visited at home or in the geriatric institution and after giving informed consent, the study variables were collected. These included: supine and standing blood pressure and information about diagnosis and treatment of hypertension. The estimation and 95% confidence interval were obtained and a logistic regression model was used to study explanatory variables associated with blood pressure below 140/90 mm Hg. The prevalence of hypertension was 72.8% (95%CI: 69.5-76.6%) and 93% of the patients were aware of this condition, of whom 96.3% (95%CI: 93.65-97.9%) had been prescribed pharmacological treatment and 30.7% (95%CI: 25.8 - 36.1%) had blood pressure below 140/90 mm Hg. Some of the patients (43%) had one antihypertensive drug and 39.5% had two in combination. Explanatory variables associated with blood pressure below 140/90 mm Hg included prescription of a diuretic, OR: 0.31 (95%CI: 0.14-0.66), and history of ischemic heart disease, OR: 0.21 (95%CI: 0.1-0.47). The prevalence of hypertension in population aged 80 or more was over 70%. Most patients were aware of this condition and they had antihypertensive medication prescribed. Approximately one third of treated patients had blood pressure below 140/90 mm Hg. Patients with heart disease and with diuretics had more frequently blood pressure below this value.
Aguado, Alba; López, Flora; Miravet, Sonia; Oriol, Pilar; Fuentes, M Isabel; Henares, Belén; Badia, Teresa; Esteve, Lluis; Peligro, Javier
2009-01-01
Background Information on hypertension in the very elderly is sparse. Until recently evidence of benefits from pharmacological treatment was inconclusive. We estimated the prevalence of hypertension in subjects aged 80 or more, the proportion of awareness, treatment and control. Explanatory variables associated with good control were also studied. Methods Cross sectional, population-based study, conducted in Martorell, an urban Spanish municipality, in 2005. By simple random sampling from the census, 323 subjects aged 80 or more were included. Patients were visited at home or in the geriatric institution and after giving informed consent, the study variables were collected. These included: supine and standing blood pressure and information about diagnosis and treatment of hypertension. The estimation and 95% confidence interval were obtained and a logistic regression model was used to study explanatory variables associated with blood pressure below 140/90 mm Hg. Results The prevalence of hypertension was 72.8% (95%CI: 69.5 – 76.6%) and 93% of the patients were aware of this condition, of whom 96.3% (95%CI: 93.65 – 97.9%) had been prescribed pharmacological treatment and 30.7% (95%CI: 25.8 – 36.1%) had blood pressure below 140/90 mm Hg. Some of the patients (43%) had one antihypertensive drug and 39.5% had two in combination. Explanatory variables associated with blood pressure below 140/90 mm Hg included prescription of a diuretic, OR: 0.31 (95%CI: 0.14 – 0.66), and history of ischemic heart disease, OR: 0.21 (95%CI: 0.1 – 0.47). Conclusion The prevalence of hypertension in population aged 80 or more was over 70%. Most patients were aware of this condition and they had antihypertensive medication prescribed. Approximately one third of treated patients had blood pressure below 140/90 mm Hg. Patients with heart disease and with diuretics had more frequently blood pressure below this value. PMID:19426484
Ohlsson, Pelle; Petersson, Klara; Augustsson, Per; Laurell, Thomas
2018-06-14
Sepsis is a common and often deadly systemic response to an infection, usually caused by bacteria. The gold standard for finding the causing pathogen in a blood sample is blood culture, which may take hours to days. Shortening the time to diagnosis would significantly reduce mortality. To replace the time-consuming blood culture we are developing a method to directly separate bacteria from red and white blood cells to enable faster bacteria identification. The blood cells are moved from the sample flow into a parallel stream using acoustophoresis. Due to their smaller size, the bacteria are not affected by the acoustic field and therefore remain in the blood plasma flow and can be directed to a separate outlet. When optimizing for sample throughput, 1 ml of undiluted whole blood equivalent can be processed within 12.5 min, while maintaining the bacteria recovery at 90% and the blood cell removal above 99%. That makes this the fastest label-free microfluidic continuous flow method per channel to separate bacteria from blood with high bacteria recovery (>80%). The high throughput was achieved by matching the acoustic impedance of the parallel stream to that of the blood sample, to avoid that acoustic forces relocate the fluid streams.
Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio
2012-01-01
Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296
Microfluidic, marker-free isolation of circulating tumor cells from blood samples
Karabacak, Nezihi Murat; Spuhler, Philipp S; Fachin, Fabio; Lim, Eugene J; Pai, Vincent; Ozkumur, Emre; Martel, Joseph M; Kojic, Nikola; Smith, Kyle; Chen, Pin-i; Yang, Jennifer; Hwang, Henry; Morgan, Bailey; Trautwein, Julie; Barber, Thomas A; Stott, Shannon L; Maheswaran, Shyamala; Kapur, Ravi; Haber, Daniel A; Toner, Mehmet
2014-01-01
The ability to isolate and analyze rare circulating tumor cells (CTCs) has the potential to further our understanding of cancer metastasis and enhance the care of cancer patients. In this protocol, we describe the procedure for isolating rare CTCs from blood samples by using tumor antigen–independent microfluidic CTC-iChip technology. The CTC-iChip uses deterministic lateral displacement, inertial focusing and magnetophoresis to sort up to 107 cells/s. By using two-stage magnetophoresis and depletion antibodies against leukocytes, we achieve 3.8-log depletion of white blood cells and a 97% yield of rare cells with a sample processing rate of 8 ml of whole blood/h. The CTC-iChip is compatible with standard cytopathological and RNA-based characterization methods. This protocol describes device production, assembly, blood sample preparation, system setup and the CTC isolation process. Sorting 8 ml of blood sample requires 2 h including setup time, and chip production requires 2–5 d. PMID:24577360
Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.
1991-01-01
The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.
2012-01-01
Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433
Cannabis Effects on Driving Skills
Hartman, Rebecca L.; Huestis, Marilyn A.
2013-01-01
BACKGROUND Cannabis is the most prevalent illicit drug identified in impaired drivers. The effects of cannabis on driving continue to be debated, making prosecution and legislation difficult. Historically, delays in sample collection, evaluating the inactive Δ9-tetrahydrocannabinol (THC) metabolite 11-nor-9-carboxy-THC, and polydrug use have complicated epidemiologic evaluations of driver impairment after cannabis use. CONTENT We review and evaluate the current literature on cannabis’ effects on driving, highlighting the epidemiologic and experimental data. Epidemiologic data show that the risk of involvement in a motor vehicle accident (MVA) increases approximately 2-fold after cannabis smoking. The adjusted risk of driver culpability also increases substantially, particularly with increased blood THC concentrations. Studies that have used urine as the biological matrix have not shown an association between cannabis and crash risk. Experimental data show that drivers attempt to compensate by driving more slowly after smoking cannabis, but control deteriorates with increasing task complexity. Cannabis smoking increases lane weaving and impaired cognitive function. Critical-tracking tests, reaction times, divided-attention tasks, and lane-position variability all show cannabis-induced impairment. Despite purported tolerance in frequent smokers, complex tasks still show impairment. Combining cannabis with alcohol enhances impairment, especially lane weaving. SUMMARY Differences in study designs frequently account for inconsistencies in results between studies. Participant-selection bias and confounding factors attenuate ostensible cannabis effects, but the association with MVA often retains significance. Evidence suggests recent smoking and/or blood THC concentrations 2–5 ng/mL are associated with substantial driving impairment, particularly in occasional smokers. Future cannabis-and-driving research should emphasize challenging tasks, such as divided attention, and include occasional and chronic daily cannabis smokers. PMID:23220273
Epidemiology of Candida isolates from Intensive Care Units in Colombia from 2010 to 2013.
Motoa, Gabriel; Muñoz, Juan Sebastián; Oñate, José; Pallares, Christian José; Hernández, Cristhian; Villegas, María Virginia
The frequency of Candida isolates as a cause of hospital infections has risen in recent years, leading to high rates of morbidity and mortality. The knowledge of the epidemiology of those hospital acquired fungal infections is essential to implement an adequate antifungal therapy. To describe the epidemiology of Candida infections in Intensive Care Units (ICUs) from a surveillance network in Colombia. Information was collected from the microbiology laboratories of 20 tertiary healthcare institutions from 10 Colombian cities using the Whonet® software version 5.6. A general descriptive analysis of Candida species and susceptibility profiles focusing on fluconazole and voriconazole was completed between 2010 and 2013, including a sub-analysis of healthcare associated infections (HAIs) during the last year. Candida isolates made up 94.5% of the 2680 fungal isolates considered, with similar proportions for Candida albicans and non-C. albicans Candida species (48.3% and 51.7%, respectively). Among the latter, Candida tropicalis (38.6%) and Candida parapsilosis (28.5%) were the most frequent species. Of note, among the blood isolates C. albicans was not the main species. Most of the species isolated were susceptible to fluconazole and voriconazole. From the HAIs reported, 25.5% were caused by Candida; central line-associated bloodstream infection was the most common HAI (58.8%). There were no statistically significant differences regarding length of hospital stay and device days among HAIs. In ICUs of Colombia, non-C. albicans Candida species are as frequent as C. albicans, except in blood samples where non-C. albicans Candida isolates predominate. Further studies are needed to evaluate Candida associated risk factors and to determine its clinical impact. Copyright © 2016 Asociación Española de Micología. Publicado por Elsevier España, S.L.U. All rights reserved.
Foo, Lee Kien; McGree, James; Duffull, Stephen
2012-01-01
Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models. Copyright © 2012 John Wiley & Sons, Ltd.
Dayre McNally, J; Matheson, Loren A; Sankaran, Koravangattu; Rosenberg, Alan M
2008-11-01
This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.
Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.
2015-01-01
Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197
Nirogi, Ramakrishna; Ajjala, Devender Reddy; Kandikere, Vishwottam; Aleti, Raghupathi; Srikakolapu, SuryaRao; Vurimindi, Himabindu
2012-10-15
Deferasirox is an iron chelating agent for the treatment of transfusional iron over load in patients with chronic anemia. These anemic patients require close monitoring of the deferasirox exposures for ensuring its therapeutic efficacy. Dried blood spot (DBS) sampling methodology has the advantages of low volume of blood withdrawal and ease of transportation and storage over liquid blood methods. A LC-MS/MS based analytical method was developed using reversed phase column with gradient elution program and quantitated in MRM mode. Linearity range for the liquid blood was 1-1000 ng/mL and for DBS was 5-5000 ng/mL under similar mass spectrometry conditions. The method was validated with respective (M-H)(-) ions, m/z 372→118 for deferasirox and m/z 410→348 for fluvastatin (internal standard). The validated method was applied for the analysis of DBS samples from a rat pharmacokinetic study and results were compared against liquid blood samples from the same animal. The mean C(max) from DBS sample (1121 ng/mL) was comparable to mean C(max) found in blood samples (1015 ng/mL) at 2h after oral dose of deferasirox. All the other calculated pharmacokinetic parameters were quite comparable for both liquid blood and DBS samples. Copyright © 2012. Published by Elsevier B.V.
Cura, C I; Lucero, R H; Bisio, M; Oshiro, E; Formichelli, L B; Burgos, J M; Lejona, S; Brusés, B L; Hernández, D O; Severini, G V; Velazquez, E; Duffy, T; Anchart, E; Lattes, R; Altcheh, J; Freilij, H; Diez, M; Nagel, C; Vigliano, C; Favaloro, L; Favaloro, R R; Merino, D E; Sosa-Estani, S; Schijman, A G
2012-04-01
Genetic diversity of Trypanosoma cruzi may play a role in pathogenesis of Chagas disease forms. Natural populations are classified into 6 Discrete Typing Units (DTUs) Tc I-VI with taxonomical status. This study aimed to identify T. cruzi DTUs in bloodstream and tissue samples of Argentinean patients with Chagas disease. PCR-based strategies allowed DTU identification in 256 clinical samples from 239 Argentinean patients. Tc V prevailed in blood from both asymptomatic and symptomatic cases and Tc I was more frequent in bloodstream, cardiac tissues and chagoma samples from immunosuppressed patients. Tc II and VI were identified in a minority of cases, while Tc III and Tc IV were not detected in the studied population. Interestingly, Tc I and Tc II/VI sequences were amplified from the same skin biopsy slice from a kidney transplant patient suffering Chagas disease reactivation. Further data also revealed the occurrence of mixed DTU populations in the human chronic infection. In conclusion, our findings provide evidence of the complexity of the dynamics of T. cruzi diversity in the natural history of human Chagas disease and allege the pathogenic role of DTUs I, II, V and VI in the studied population.
Bacteria associated with Amblyomma cajennense tick eggs
Machado-Ferreira, Erik; Vizzoni, Vinicius Figueiredo; Piesman, Joseph; Gazeta, Gilberto Salles; Soares, Carlos Augusto Gomes
2015-01-01
Abstract Ticks represent a large group of pathogen vectors that blood feed on a diversity of hosts. In the Americas, the Ixodidae ticks Amblyomma cajennense are responsible for severe impact on livestock and public health. In the present work, we present the isolation and molecular identification of a group of culturable bacteria associated with A. cajennense eggs from females sampled in distinct geographical sites in southeastern Brazil. Additional comparative analysis of the culturable bacteria from Anocentor nitens, Rhipicephalus sanguineus and Ixodes scapularis tick eggs were also performed. 16S rRNA gene sequence analyses identified 17 different bacterial types identified as Serratia marcescens, Stenotrophomonas maltophilia, Pseudomonas fluorescens, Enterobacter spp., Micrococcus luteus, Ochrobactrum anthropi, Bacillus cereus and Staphylococcus spp., distributed in 12 phylogroups. Staphylococcus spp., especially S. sciuri, was the most prevalent bacteria associated with A. cajennense eggs, occurring in 65% of the samples and also frequently observed infecting A. nitens eggs. S. maltophilia, S. marcescens and B. cereus occurred infecting eggs derived from specific sampling sites, but in all cases rising almost as pure cultures from infected A. cajennense eggs. The potential role of these bacterial associations is discussed and they possibly represent new targets for biological control strategies of ticks and tick borne diseases. PMID:26537602
Stability of selected serum proteins after long-term storage in the Janus Serum Bank.
Gislefoss, Randi E; Grimsrud, Tom K; Mørkrid, Lars
2009-01-01
Human serum from biobanks is frequently used in prospective epidemiological studies. Long-term storage may modify its composition. A better understanding of the stability of the serum components may improve the interpretation of future studies. The concentrations of selected proteins; immunoglobulins, carrier proteins and enzymes in samples stored at -25 degrees C for 25 years and 2 years were compared with 1-month-old samples. For each length of storage time, 130 specimens were randomly selected from apparently healthy male blood donors aged 40-49 years. We examined the distribution of values, compared dispersion and localization of central tendency, and established reference intervals for each component. The study demonstrated non-significant or numerically small group differences in the concentrations of albumin, aspartate amino transferase, cystatin C, immunoglobulin E, immunoglobulin G, and sex hormone binding globulin. Mean values between fresh and 25-year-old samples suggested larger differences during storage for alanine amino transferase (-73.4%), creatinine kinase (-96.1%), insulin C-peptide (-98.7%), ferritin (-18.5%) and transferrin (+8.2%). The findings showed that long-term storage can introduce a considerable bias for vulnerable components.
Fajfr, Miroslav; Pliskova, Lenka; Kutova, Radka; Matyskova-Kubisova, Michaela; Navratil, Pavel; Radocha, Jakub; Valenta, Zbynek; Dusilova-Sulkova, Sylvie
2017-12-01
Human polyomaviruses such as JC polyomavirus and BK polyomavirus have long been well known pathogens of immunocompromised patients. Several new members of this viral family have been described during the last decade. Human polyomavirus 9 seems to be a novel pathogen of transplanted patients according to some studies. The aim of our study was to determine the presence of human polyomavirus 9 in patients after kidney or stem cell transplantation (SCT) at the University Hospital in Hradec Kralove, Czech Republic. Overall 100 patients, 65 after kidney transplantation and 35 after SCT, were included into the study. At least three follow-up samples from each patient were examined for human polyomavirus 9 DNA presentation with the two previously described in-house PCR protocols. Despite the frequent reactivation of human CMV (14.3% in kidney transplantation and 63.3% after SCT) or BK polyomavirus in our patient group, there was no positivity for human polyomavirus 9 either in blood samples or urine samples. One of the possible reasons for this discrepancy versus previous published studies could be a relatively low proportion of patients treated by induction therapy before kidney transplantation in our study cohort. © 2017 Wiley Periodicals, Inc.
Impact of Parvovirus B19 Viremia in Liver Transplanted Children on Anemia: A Retrospective Study
Würdinger, Michael; Modrow, Susanne; Plentz, Annelie
2017-01-01
Acute parvovirus B19 (B19V) infection in immunocompromised patients may lead to severe anemia. However, in adult transplant recipients, B19V reactivations without anemia and low-level viremia are common. The impact of B19V in pediatric transplant patients, with high risk of primary infection, is investigated here. In a six-month period, 159 blood samples of 54 pediatric liver transplant recipients were tested for B19V DNA by quantitative real-time PCR. Viremia was correlated with anemia and immunosuppression and compared with rates in adult transplant recipients. B19V DNA was detected in 5/54 patients. Primary B19V infections were observed in four patients prior to and in one patient after transplantation. Rates of viremia were significantly higher in pediatric recipients than in adults. Prolonged virus shedding after primary infection prior to transplantation accounts for most viremic cases. Anemia was significantly more frequent in samples from viremic patients, but remained mild. In 15% of anemic samples, B19V DNA was detected. Therefore, in anemic pediatric transplant recipients, diagnostics for B19V seem reasonable. PMID:28608818
Feline immudeficiency virus subtypes B and A in cats from São Luis, Maranhão, Brazil.
Martins, Nathálya Dos S; Rodrigues, Ana Paula de S; da Luz, Luciana A; Dos Reis, Luana da L; de Oliveira, Renata M; de Oliveira, Rudson A; Abreu-Silva, Ana Lucia; Dos Reis, Jenner Karlisson P; Melo, Ferdinan A
2018-02-01
Feline immunodeficiency virus (FIV) is a retrovirus of the genus Lentivirus that is distributed worldwide, with prevalence rates varying between 2.5% and 44%. FIV causes immunosuppression, with depletion of TCD4 + lymphocytes, with the majority of clinical signs caused by secondary and opportunistic infections. Blood samples were collected from nine domestic cats (Felis catus domesticus) from the city of São Luís, Maranhão State, Brazil. All samples were positive in a rapid immunochromatographic test (SNAP® Combo FeLV Ag/FIV Antibody Test) and in a polymerase chain reaction (PCR) assay. Phylogenetic analysis showed that six samples clustered within subtype B, one within subtype A, and two did not cluster with any known subtype. Five unique haplotypes (Hap-1, Hap-2, Hap-3, Hap-5 and Hap-6) and a shared haplotype (Hap-4) were found, this last one being the most frequent. This is the first report on the genetic diversity of FIV in the city of São Luís and the first report of subtype A in Brazil. New variations of the virus are also reported.
Gram-negative diabetic foot osteomyelitis: risk factors and clinical presentation.
Aragón-Sánchez, Javier; Lipsky, Benjamin A; Lázaro-Martínez, Jose L
2013-03-01
Osteomyelitis frequently complicates infections in the feet of patients with diabetes. Gram-positive cocci, especially Staphylococcus aureus, are the most commonly isolated pathogens, but gram-negative bacteria also cause some cases of diabetic foot osteomyelitis (DFO). These gram-negatives require different antibiotic regimens than those commonly directed at gram-positives. There are, however, few data on factors related to their presence and how they influence the clinical picture. We conducted a retrospective study to determine the variables associated with the isolation of gram-negative bacteria from bone samples in cases of DFO and the clinical presentation of these infections. Among 341 cases of DFO, 150 had a gram-negative isolate (alone or combined with a gram-positive isolate) comprising 44.0% of all patients and 50.8% of those with a positive bone culture. Compared with gram-positive infections, wounds with gram-negative organisms more often had a fetid odor, necrotic tissue, signs of soft tissue infection accompanying osteomyelitis, and clinically severe infection. By multivariate analysis, the predictive variables related to an increased likelihood of isolating gram-negatives from bone samples were glycated hemoglobin <7% (odds ratio [OR] = 2.0, 95% confidence interval [CI] = 1.1-3.5) and a wound caused by traumatic injury (OR = 2.0, 95% CI = 1.0-3.9). Overall, patients whose bone samples contained gram-negatives had a statistically significantly higher prevalence of leukocytosis and higher white blood cell counts than those without gram-negatives. In conclusion, gram-negative organisms were isolated in nearly half of our cases of DFO and were associated with more severe infections, higher white blood cell counts, lower glycated hemoglobin levels, and wounds of traumatic etiology.
Heervä, Eetu; Alanne, Maria H; Peltonen, Sirkku; Kuorilehto, Tommi; Hentunen, Teuvo; Väänänen, Kalervo; Peltonen, Juha
2010-09-01
Neurofibromatosis 1 syndrome (NF1) presents with skeletal involvement suggesting that altered bone dynamics is associated with NF1. Histological analysis of three cases of NF1-related pseudarthrosis revealed numerous osteoclasts in contact with adjacent bone, and within the pseudarthrosis tissue itself. These findings prompted us to evaluate the differentiation and resorption capacity of NF1-osteoclast like cells (OLCs) in vitro. Osteoclast progenitors were isolated from peripheral blood of 17 patients with NF1 and allowed to differentiate into OLCs on bone slices. The following differences were found between NF1 and control samples: samples from NF1 patients resulted in a higher number of resorbing OLCs; NF1 OLCs were larger in size; their nuclei were more numerous; actin rings were more frequent; and the resorption pits in NF1 samples were more numerous and larger. Bone resorption markers revealed that the resorption activity in NF1 OLC cultures was approximately two times higher than in controls. Following deprivation from serum, the number of NF1 OLCs remained essentially the same during 24h, whereas the number of control OLCs was dramatically reduced during the same time. Three patients had NF1-related lytic bone lesions, and their in vitro results differed from those of other patients. Our results demonstrate that OLCs derived from blood of patients with NF1 display elevated resorption activity under conditions isolated from microenvironment operative in vivo. Thus, increased osteoclast activity may be a phenotypic property of the NF1 syndrome, and at least in part explain selected skeletal findings in NF1, such as osteoporosis/osteopenia. Copyright 2010 Elsevier Inc. All rights reserved.
Accuracy of pulse oximetry in children.
Ross, Patrick A; Newth, Christopher J L; Khemani, Robinder G
2014-01-01
For children with cyanotic congenital heart disease or acute hypoxemic respiratory failure, providers frequently make decisions based on pulse oximetry, in the absence of an arterial blood gas. The study objective was to measure the accuracy of pulse oximetry in the saturations from pulse oximetry (SpO2) range of 65% to 97%. This institutional review board-approved prospective, multicenter observational study in 5 PICUs included 225 mechanically ventilated children with an arterial catheter. With each arterial blood gas sample, SpO2 from pulse oximetry and arterial oxygen saturations from CO-oximetry (SaO2) were simultaneously obtained if the SpO2 was ≤ 97%. The lowest SpO2 obtained in the study was 65%. In the range of SpO2 65% to 97%, 1980 simultaneous values for SpO2 and SaO2 were obtained. The bias (SpO2 - SaO2) varied through the range of SpO2 values. The bias was greatest in the SpO2 range 81% to 85% (336 samples, median 6%, mean 6.6%, accuracy root mean squared 9.1%). SpO2 measurements were close to SaO2 in the SpO2 range 91% to 97% (901 samples, median 1%, mean 1.5%, accuracy root mean squared 4.2%). Previous studies on pulse oximeter accuracy in children present a single number for bias. This study identified that the accuracy of pulse oximetry varies significantly as a function of the SpO2 range. Saturations measured by pulse oximetry on average overestimate SaO2 from CO-oximetry in the SpO2 range of 76% to 90%. Better pulse oximetry algorithms are needed for accurate assessment of children with saturations in the hypoxemic range.
Helmus, Janine; Zorell, Sarah; Bajanowski, Thomas; Poetsch, Micaela
2018-01-01
DNA traces on clothes of drowned bodies can provide important evidence for police investigations, especially in cases of suspected suicides or homicides. However, it is generally assumed that the water "erodes" a large part of the DNA depending especially on the exposure time. In forensic casework, DNA of suspects could be found frequently on clothes of drowned bodies after hours, sometimes days of exposure to water. This study was conducted to attempt a general statement about the conditions under which sufficient DNA remains can be expected for molecular genetic analysis. For this purpose, different scenarios were designed including DNA from three to five people, different types of waters (tap, pond, bathtub and river) for various time periods, with higher water pressure, different temperature, and soapy water (bathtub). Epithelial cells and blood cells were mounted on cotton cloths, and the DNA left after exposure was analyzed using the Powerplex® ESX17fast kit. In the indoor experiments, complete profiles could be seen even after 10 min rinsing of clothes under the tap and after 1 week in the bathtub. Outdoors, the results differed considerably between summer and winter as well as between pond and river. The longest exposure time still resulting in a complete profile was 2 weeks for a sample with skin cells in the pond during winter. In summer, the time period for erasing the bulk of DNA was 4 hours regarding epithelial samples and more than 1 day for blood samples in pond and river environments. All in all, the results demonstrate that DNA could still be recovered from clothes exposed to water for more than 1 week.