Sample records for frp denture base

  1. [Development of visible-light cured FRP denture].

    PubMed

    Yu, P Y

    1990-06-01

    Acrylic denture may be fractured easily because it has a relatively poor resistance to stresses of impact, and the thick acrylic denture base also uncomforted to denture wearers. In this study, for improvement of the mechanical properties, the FRP is applied to the denture base, and try to make a thin denture base. Using the visible light-curing system, the laboratory fabrication time is saved dramatically. To develop the visible light-cured FRP denture base, with various combination of matrix resins and reinforcements, the physical properties of FRP plates were investigated first. From the results of the bending test, hardness test, and manipulation considering, the sateen weave's glasscloth was choose as the reinforcement of the prepreg. The matrix resin of Bis-GMA/UDMA/3G at 48/48/4 wt% was determined. The 3 plies glasscloth included FRP plate is 0.8 mm thickness has the maximum bending strength about 50 kgf/mm2, which is about 5 times larger than that of acrylic resin. Succeeding the study of above, the FRP denture base was fabricated by using the 0.8 mm thickness 3 plies included prepreg. This repreg is manufactured in sheet form beforehand, which is ease to manipulate at laboratory. By using the visible light curing system, it is only taken 10 min. to make a FRP denture base. The following procedures of fabricating a FRP denture is the same as metalplate denture. The visible-light cured FRP denture has some advantages such as accuracy of fit, ease of fabrication and manipulation, and only 0.8 mm thickness but has superior strength.

  2. A development of visible light cured FRP plate denture.

    PubMed

    Kimura, H; Teraoka, F

    1990-12-01

    A FRP denture base, which was made from visible light curing prepreg, was developed. The visible light cured FRP denture base had advantages with respect to an adequate strength, bonding strength of acrylic base resin, esthetic properties and ease to manipulation. The matrix resin of Bis-GMA/UDMA/3 G at 48/48/4 was determined from the results of the bending test and manipulation processing. The sateen weave's glasscloth was used for the reinforcement of the prepreg. The adaptability of the FRP plate denture was better than that of the resin base denture constructed with microwave heating.

  3. [Development of denture base resin. 2. Manufacturing of visible-light cured prepreg and physical properties of FRP].

    PubMed

    Kimura, H; Yu, P Y; Teraoka, F; Sugita, M

    1989-09-01

    To develop the visible light-cured FRP denture base, we investigated the physical properties and the warp of FRP plate by using various combinations of matrix resin and reinforcement. From the results of the bending test, hardness test and manipulation processing, the matrix resin of Bis-GMA/UDMA/3 G at 48/48/4 wt% was determined. The sateen weave's glasscloth as the reinforcement of the prepreg was used. The maximum plies included FRP of 0.5 mm, 0.8 and 1.0 mm thickness have the same maximum bending strengths of 45 kgf/mm2, which is about 5 times larger than that of conventional acrylic resin. The warp of these FRP plates were not found.

  4. Smart FBG-based FRP anchor

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Zhang, Zhichun; Wang, Chuan; Ou, Jinping

    2006-03-01

    FRP ( Fiber Reinforced Polymer ) has become the popular material to alternate steel in civil engineering under harsh corrosion environment. But due to its low shear strength ability, the anchor for FRP is most important for its practical application. However, the strain state of the surface between FRP and anchor is not fully understood due to that there is no proper sensor to monitor the inner strain in the anchor by traditional method. In this paper, a new smart FBG-based FRP anchor is brought forward, and the inner strain distribution of FRP anchor has been monitored using FRP-OFBG sensors, a smart FBG-embedded FRP rebar, which is pre-embedded in the FRP rod and cast in the anchor. Based on the strain distribution information the bonding shear stress on the surface of FRP rod along the anchor can also be obtained. This method can supply important information for FRP anchor design and can also monitor the anchorage system, which is useful for the application of FRP in civil engineering. The experimental results also show that the smart FBG-based FRP anchor can give direct information of the load and damage of the FRP anchor.

  5. Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures.

    PubMed

    Stawarczyk, Bogna; Lümkemann, Nina; Eichberger, Marlis; Wimmer, Timea

    2017-12-19

    The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL)-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D) software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x -, y - and z -axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the vicinity of the denture teeth area and the bases. The conventional transfer of CAD/CAM-fabricated wax dentures into acrylic resin leads to the highest deviations from the STL-reference.

  6. Study on the quality of FRP fishing vessel based on improved Fishbone Chart

    NASA Astrophysics Data System (ADS)

    Sui, J. H.; Yu, Y. F.; Du, Q. F.; Jiang, D. W.

    2018-01-01

    The construction quality of FRP fishing vessels influences their production, use and industry development. In order to explore the factors that affect the construction quality of FRP fishing vessels, key factors affecting the construction quality of FRP fishing vessels are determined based on the quality problems of FRP fishing vessels constructed. The improved Fishbone Chart is used to analyze the eight factors of “human, machine, material, process, environment, inspection, design and information”. Taking the factors that affect the construction quality of FRP fishing vessels as the central target, the eight influencing factors were condensed into five aspects and a composite Fishbone Chart is drawn. The Fishbone Chart is used as the basic model, the influencing factors are sorted, screened and discriminated, and the system model convenient for construction site management and control is established. Finally, the causes of poor construction of FRP fishing vessels are analyzed and discussed, and relevant suggestions are put forward.

  7. Comparison of retention between maxillary milled and conventional denture bases: A clinical study.

    PubMed

    AlHelal, Abdulaziz; AlRumaih, Hamad S; Kattadiyil, Mathew T; Baba, Nadim Z; Goodacre, Charles J

    2017-02-01

    Clinical studies comparing the retention values of milled denture bases with those of conventionally processed denture bases are lacking. The purpose of this clinical study was to compare the retention values of conventional heat-polymerized denture bases with those of digitally milled maxillary denture bases. Twenty individuals with completely edentulous maxillary arches participated in this study. Definitive polyvinyl siloxane impressions were scanned (iSeries; Dental Wings), and the standard tessellation language files were sent to Global Dental Science for the fabrication of a computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base (group MB) (AvaDent). The impression was then poured to obtain a definitive cast that was used to fabricate a heat-polymerized acrylic resin denture base resin (group HB). A custom-designed testing device was used to measure denture retention (N). Each denture base was subjected to a vertical pulling force by using an advanced digital force gauge 3 times at 10-minute intervals. The average retention of the 2 fabrication methods was compared using repeated ANOVA (α=.05). Significantly increased retention was observed for the milled denture bases compared with that of the conventional heat-polymerized denture bases (P<.001). The retention offered by milled complete denture bases from prepolymerized poly(methyl methacrylate) resin was significantly higher than that offered by conventional heat- polymerized denture bases. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Effect of denture cleansers on color stability, surface roughness, and hardness of different denture base resins

    PubMed Central

    Porwal, Anand; Khandelwal, Meenakshi; Punia, Vikas; Sharma, Vivek

    2017-01-01

    Aim: The purpose of this study was to evaluate the effect of different denture cleansers on the color stability, surface hardness, and roughness of different denture base resins. Materials and Methods: Three denture base resin materials (conventional heat cure resin, high impact resin, and polyamide denture base resin) were immersed for 180 days in commercially available two denture cleansers (sodium perborate and sodium hypochlorite). Color, surface roughness, and hardness were measured for each sample before and after immersion procedure. Statistical Analysis: One-way analysis of variance and Tukey's post hoc honestly significant difference test were used to evaluate color, surface roughness, and hardness data before and after immersion in denture cleanser (α =0.05). Results: All denture base resins tested exhibited a change in color, surface roughness, and hardness to some degree in both denture cleansers. Polyamides resin immersed in sodium perborate showed a maximum change in color after immersion for 180 days. Conventional heat cure resin immersed in sodium hypochlorite showed a maximum change in surface roughness and conventional heat cure immersed in sodium perborate showed a maximum change in hardness. Conclusion: Color changes of all denture base resins were within the clinically accepted range for color difference. Surface roughness change of conventional heat cure resin was not within the clinically accepted range of surface roughness. The choice of denture cleanser for different denture base resins should be based on the chemistry of resin and cleanser, denture cleanser concentration, and duration of immersion. PMID:28216847

  9. On the clinical deformation of maxillary complete dentures. Influence of denture-base design and shape of denture-bearing tissue.

    PubMed

    el Ghazali, S; Glantz, P O; Strandman, E; Randow, K

    1989-04-01

    This paper aimed to study the influence of denture base design and the shape of the denture-supporting area on the functional deformation of maxillary complete dentures. Six strain-gauged duplicate maxillary dentures were made for the study of two test subjects with different shapes of the palatal vault. Each subject was supplied with two polymethyl methacrylate dentures, one with a 1-mm-thick palatal base and the other 2 mm thick. A third denture was constructed with a cobalt-chromium base. The functional loading tests included maximum biting and the chewing of the food test samples. An analysis based on chewing time and total number of chewing cycles per test piece was also made. The results showed that surface straining is highly complex at the anterior part of the maxillary dentures constructed from polymethyl methacrylate and that increasing the denture thickness per se might not be accompanied by a reduction of strain. The results also suggest that high thrust to the supporting tissue is produced with high palatal vault dentures made in polymethyl methacrylate. The study proposes that cobalt-chromium bases may be used in maxillary dentures to reduce functional deformation and thrust to the supporting tissues at the anterior part of the maxilla.

  10. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.

    PubMed

    Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-03-08

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.

  11. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins

    PubMed Central

    Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022

  12. Bonding of acrylic denture teeth to MMA/PMMA and light-curing denture base materials: the role of conditioning liquids.

    PubMed

    Palitsch, Anne; Hannig, Matthias; Ferger, Paul; Balkenhol, Markus

    2012-03-01

    The connection between resin denture teeth and the denture base is essential for the integrity of partial and full dentures. The aim of the present study was to analyse the bond strength of acrylic denture teeth to two light curing denture base materials compared to the gold-standard (MMA/PMMA) using different conditioning liquids. The ridge laps of 220 identical denture teeth were ground and pre-treated using different conditioning liquids (MMA, an experimental conditioning liquid as well as the two commercially available liquids Palabond and Versyo.bond). The denture base materials (PalaXpress, Versyo.com, Eclipse) were applied using a split mould to obtain tensile bond strength specimens of identical shape. Ten specimens per test group were either stored in water for 24h or thermocycled (5000×, 5-55°C) prior to tensile bond strength testing (cross-head speed 10mm/min). Data was subjected to parametric statistics (α=0.05). The three-way ANOVA revealed a significant influence of the material, pre-treatment as well as the storage. PalaXpress showed the highest bond strength (24.3MPa) of all materials tested after TC, whereas the use of MMA led to the most constant results. Lower values were recorded for Versyo.com (17.5MPa) and Eclipse (10.4MPa) bonded with Versyo.bond. The results indicate that MMA/PMMA based denture base resins provide reliable and durable bond strength to acrylic denture teeth. Using light-curing denture base materials requires the application of appropriate conditioning liquids to obtain acceptable bond strength. The use of MMA affects bond strength to light-curing denture base materials. The pre-treatment of denture teeth is critical regarding their bond-strength to denture base materials and in turn for the integrity of removable full and partial dentures. Light-curing denture base resins are more sensitive to the correct tooth pre-treatment compared to conventional MMA/PMMA materials, requiring specific conditioning liquids. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Elimination of deck joints using a corrosion resistant FRP approach.

    DOT National Transportation Integrated Search

    2009-09-01

    The research presented herein describes the development of durable link slabs for jointless bridge decks based on : using a fiber reinforced polymer (FRP) grid for reinforcement. Specifically the ductility of the FRP material was : utilized to accomm...

  14. Elimination of deck joints using a corrosion resistant FRP approach.

    DOT National Transportation Integrated Search

    2009-09-01

    The research presented herein describes the development of durable link slabs for jointless bridge decks based on using a fiber reinforced polymer (FRP) grid for reinforcement. Specifically the ductility of the FRP material was utilized to accommodat...

  15. Investigation of mRNA expression for secreted frizzled-related protein 2 (sFRP2) in chick embryos.

    PubMed

    Lin, Chung-Tien; Lin, Yu-Ting; Kuo, Tzong-Fu

    2007-08-01

    The roles of secreted frizzled-related protein 2 (sFRP2) in organ development of vertebrate animals are not well understood. We investigated expression of sFRP2 during embryogenesis of Arbor Acre broiler chicken eggs. Expression of sFRP2 was detected in the folds and lateral layer of developing brains. The sFRP2 signals in the developing eye were marked as a circle along the orbit. In younger embryos on days 3-6, the sFRP2 signals were consistent with growth of the sclerotome, suggesting that sFRP2 may be associated with somite development. Furthermore, with the exception of bones, sFRP2 mRNA was detectable in the interdigital tissue of embryos older than eight days as the limbs matured. This revealed that sFRP2 might play a role in myogenesis. In situ hybridization was also used to analyze the expression of sFRP2 in day 3-10 chick embryos. Signals were expressed in the gray matter of the developing brain coelom, including the optic lobe, metencephalon, myelencephalon, mesencephalon and diencephalon. The developing eyes contained an intercellular distribution of sFRP2 in the pigmented layer of the retina and photoreceptors. Furthermore, sFRP2 was expressed in the mantle layer of the neural tube and notochord. Based on these findings, it seems reasonable to suggest that sFRP2 may play an active role in embryogenesis, especially in development of the neural system, eyes, muscles and limbs.

  16. An experimental study on the shear strength of FRP perfobond shear connector

    NASA Astrophysics Data System (ADS)

    Gwon, S. C.; Kim, S. H.; Yoon, S. J.; Choi, C. W.

    2018-06-01

    In this study, push-out tests were conducted to investigate shear behaviour of FRP perfobond shear connector. The parameters influencing shear capacity of FRP perfobond shear connector are concrete dowel effect, shear resistance effect of the laterally reinforced FRP re- bar, and frictional effect between shear connector and concrete. The specimens were designed to consider these parameters. The specimens coated with sand to increase frictional resistance between the FRP re-bar and concrete. Based on the test results and the parameters, new equation was suggested to predict shear strength of FRP perfobond shear connectors. The predicted results and the experimental results were compared to check the feasibility of prediction.

  17. Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases.

    PubMed

    Nirale, Rutuja Madhukarrao; Thombre, Ram; Kubasad, Girish

    2012-02-01

    To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n = 20). Data were analyzed using student paired 't' and unpaired 't' test. Microwave disinfection produces significant shrinkage in both denture bases without relining (t = 17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability.

  18. CAD/CAM produces dentures with improved fit.

    PubMed

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  19. Repair and retrofit of concrete bridge girders using hybrid FRP sheets.

    DOT National Transportation Integrated Search

    2012-02-01

    The use of carbon fibers (CF) and glass fibers (GF) were combined to strengthen potentially non-ductile flexural : members. Based on tension tests of fiber-reinforced polymer (FRP) rovings and sheets, as well as theoretical : research on hybrid FRP, ...

  20. Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

    PubMed Central

    Thombre, Ram; Kubasad, Girish

    2012-01-01

    PURPOSE To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n = 20). Data were analyzed using student paired 't' and unpaired 't' test. RESULTS Microwave disinfection produces significant shrinkage in both denture bases without relining (t = 17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). CONCLUSION Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability. PMID:22439097

  1. Comparative evaluation of tensile bond strength of a polyvinyl acetate-based resilient liner following various denture base surface pre-treatment methods and immersion in artificial salivary medium: An in vitro study.

    PubMed

    Philip, Jacob M; Ganapathy, Dhanraj M; Ariga, Padma

    2012-07-01

    This study was formulated to evaluate and estimate the influence of various denture base resin surface pre-treatments (chemical and mechanical and combinations) upon tensile bond strength between a poly vinyl acetate-based denture liner and a denture base resin. A universal testing machine was used for determining the bond strength of the liner to surface pre-treated acrylic resin blocks. The data was analyzed by one-way analysis of variance and the t-test (α =.05). This study infers that denture base surface pre-treatment can improve the adhesive tensile bond strength between the liner and denture base specimens. The results of this study infer that chemical, mechanical, and mechano-chemical pre-treatments will have different effects on the bond strength of the acrylic soft resilient liner to the denture base. Among the various methods of pre-treatment of denture base resins, it was inferred that the mechano-chemical pre-treatment method with air-borne particle abrasion followed by monomer application exhibited superior bond strength than other methods with the resilient liner. Hence, this method could be effectively used to improve bond strength between liner and denture base and thus could minimize delamination of liner from the denture base during function.

  2. Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments.

    PubMed

    Akin, Hakan; Tugut, Faik; Guney, Umit; Kirmali, Omer; Akar, Turker

    2013-01-01

    This study evaluated the effect of various surface treatments on the tensile bond strength of a silicone-based soft denture liner to two chemically different denture base resins, heat-cured polymethyl methacrylate (PMMA), and light-activated urethane dimethacrylate or Eclipse denture base resin. PMMA test specimens were fabricated and relined with a silicone-based soft denture liner (group AC). Eclipse test specimens were prepared according to the manufacturer's recommendation. Before they were relined with a silicone-based soft denture liner, each received one of three surface treatments: untreated (control, group EC), Eclipse bonding agent applied (group EB), and laser-irradiated (group EL). Tensile bond strength tests (crosshead speed = 5 mm/min) were performed for all specimens, and the results were analyzed using the analysis of variance followed by Tukey's test (p = 0.05). Eclipse denture base and PMMA resins presented similar bond strengths to the silicone-based soft denture liner. The highest mean force was observed in group EL specimens, and the tensile bond strengths in group EL were significantly different (p < 0.05) from those in the other groups.

  3. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

    PubMed Central

    Al-mejrad, Lamya A.; Albarrag, Ahmed M.

    2017-01-01

    PURPOSE The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures. PMID:29142649

  4. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    PubMed

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P <.05). The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  5. Effect of long-term water immersion or thermal shock on mechanical properties of high-impact acrylic denture base resins.

    PubMed

    Sasaki, Hirono; Hamanaka, Ippei; Takahashi, Yutaka; Kawaguchi, Tomohiro

    2016-01-01

    The purpose of this study was to investigate the effect of long-term water immersion or thermal shock on the mechanical properties of high-impact acrylic denture base resins. Two high-impact acrylic denture base resins were selected for the study. Specimens of each denture base material tested were fabricated according to the manufacturers' instructions (n=10). The flexural strength at the proportional limit, the elastic modulus and the impact strength of the specimens were evaluated. The flexural strength at the proportional limit of the high-impact acrylic denture base resins did not change after six months' water immersion or thermocycling 50,000 times. The elastic moduli of the high-impact acrylic denture base resins significantly increased after six months' water immersion or thermocycling 50,000 times. The impact strengths of the high-impact acrylic denture base resins significantly decreased after water immersion or thermocycling as described above.

  6. Nonlinear micromechanics-based finite element analysis of the interfacial behaviour of FRP-strengthened reinforced concrete beams

    NASA Astrophysics Data System (ADS)

    Abd El Baky, Hussien

    This research work is devoted to theoretical and numerical studies on the flexural behaviour of FRP-strengthened concrete beams. The objectives of this research are to extend and generalize the results of simple experiments, to recommend new design guidelines based on accurate numerical tools, and to enhance our comprehension of the bond performance of such beams. These numerical tools can be exploited to bridge the existing gaps in the development of analysis and modelling approaches that can predict the behaviour of FRP-strengthened concrete beams. The research effort here begins with the formulation of a concrete model and development of FRP/concrete interface constitutive laws, followed by finite element simulations for beams strengthened in flexure. Finally, a statistical analysis is carried out taking the advantage of the aforesaid numerical tools to propose design guidelines. In this dissertation, an alternative incremental formulation of the M4 microplane model is proposed to overcome the computational complexities associated with the original formulation. Through a number of numerical applications, this incremental formulation is shown to be equivalent to the original M4 model. To assess the computational efficiency of the incremental formulation, the "arc-length" numerical technique is also considered and implemented in the original Bazant et al. [2000] M4 formulation. Finally, the M4 microplane concrete model is coded in FORTRAN and implemented as a user-defined subroutine into the commercial software package ADINA, Version 8.4. Then this subroutine is used with the finite element package to analyze various applications involving FRP strengthening. In the first application a nonlinear micromechanics-based finite element analysis is performed to investigate the interfacial behaviour of FRP/concrete joints subjected to direct shear loadings. The intention of this part is to develop a reliable bond--slip model for the FRP/concrete interface. The bond--slip relation is developed considering the interaction between the interfacial normal and shear stress components along the bonded length. A new approach is proposed to describe the entire tau-s relationship based on three separate models. The first model captures the shear response of an orthotropic FRP laminate. The second model simulates the shear characteristics of an adhesive layer, while the third model represents the shear nonlinearity of a thin layer inside the concrete, referred to as the interfacial layer. The proposed bond--slip model reflects the geometrical and material characteristics of the FRP, concrete, and adhesive layers. Two-dimensional and three-dimensional nonlinear displacement-controlled finite element (FE) models are then developed to investigate the flexural and FRP/concrete interfacial responses of FRP-strengthened reinforced concrete beams. The three-dimensional finite element model is created to accommodate cases of beams having FRP anchorage systems. Discrete interface elements are proposed and used to simulate the FRP/concrete interfacial behaviour before and after cracking. The FE models are capable of simulating the various failure modes, including debonding of the FRP either at the plate end or at intermediate cracks. Particular attention is focused on the effect of crack initiation and propagation on the interfacial behaviour. This study leads to an accurate and refined interpretation of the plate-end and intermediate crack debonding failure mechanisms for FRP-strengthened beams with and without FRP anchorage systems. Finally, the FE models are used to conduct a parametric study to generalize the findings of the FE analysis. The variables under investigation include two material characteristics; namely, the concrete compressive strength and axial stiffness of the FRP laminates as well as three geometric properties; namely, the steel reinforcement ratio, the beam span length and the beam depth. The parametric study is followed by a statistical analysis for 43 strengthened beams involving the five aforementioned variables. The response surface methodology (RSM) technique is employed to optimize the accuracy of the statistical models while minimizing the numbers of finite element runs. In particular, a face-centred design (FCD) is applied to evaluate the influence of the critical variables on the debonding load and debonding strain limits in the FRP laminates. Based on these statistical models, a nonlinear statistical regression analysis is used to propose design guidelines for the FRP flexural strengthening of reinforced concrete beams. (Abstract shortened by UMI.)

  7. Use of metal conditioner on reinforcement wires to improve denture repair strengths.

    PubMed

    Shimizu, Hiroshi; Mori, Nobuaki; Takahashi, Yutaka

    2008-03-01

    The purpose of this study was to evaluate the transverse strength of denture base resin repaired with autopolymerizing resin and metal wire using a metal conditioner, along with the synergistic effect of a surface preparation for denture base resin. It was found that the use of Co-Cr-Ni wires air abraded with 50 microm alumina, followed by treatment with a metal conditioner and dichloromethane for denture base resin, was the most effective method for repairing fractured denture base resin.

  8. Crack Monitoring Method for an FRP-Strengthened Steel Structure Based on an Antenna Sensor.

    PubMed

    Liu, Zhiping; Chen, Kai; Li, Zongchen; Jiang, Xiaoli

    2017-10-20

    Fiber-reinforced polymer (FRP) has been increasingly applied to steel structures for structural strengthening or crack repair, given its high strength-to-weight ratio and high stiffness-to-weight ratio. Cracks in steel structures are the dominant hidden threats to structural safety. However, it is difficult to monitor structural cracks under FRP coverage and there is little related research. In this paper, a crack monitoring method for an FRP-strengthened steel structure deploying a microstrip antenna sensor is presented. A theoretical model of the dual-substrate antenna sensor with FRP is established and the sensitivity of crack monitoring is studied. The effects of the weak conductivity of carbon fiber reinforced polymers (CFRPs) on the performance of crack monitoring are analyzed via contrast experiments. The effects of FRP thickness on the performance of the antenna sensor are studied. The influence of structural strain on crack detection coupling is studied through strain-crack coupling experiments. The results indicate that the antenna sensor can detect cracks in steel structures covered by FRP (including CFRP). FRP thickness affects the antenna sensor's performance significantly, while the effects of strain can be ignored. The results provide a new approach for crack monitoring of FRP-strengthened steel structures with extensive application prospects.

  9. Crack Monitoring Method for an FRP-Strengthened Steel Structure Based on an Antenna Sensor

    PubMed Central

    Liu, Zhiping; Li, Zongchen

    2017-01-01

    Fiber-reinforced polymer (FRP) has been increasingly applied to steel structures for structural strengthening or crack repair, given its high strength-to-weight ratio and high stiffness-to-weight ratio. Cracks in steel structures are the dominant hidden threats to structural safety. However, it is difficult to monitor structural cracks under FRP coverage and there is little related research. In this paper, a crack monitoring method for an FRP-strengthened steel structure deploying a microstrip antenna sensor is presented. A theoretical model of the dual-substrate antenna sensor with FRP is established and the sensitivity of crack monitoring is studied. The effects of the weak conductivity of carbon fiber reinforced polymers (CFRPs) on the performance of crack monitoring are analyzed via contrast experiments. The effects of FRP thickness on the performance of the antenna sensor are studied. The influence of structural strain on crack detection coupling is studied through strain–crack coupling experiments. The results indicate that the antenna sensor can detect cracks in steel structures covered by FRP (including CFRP). FRP thickness affects the antenna sensor’s performance significantly, while the effects of strain can be ignored. The results provide a new approach for crack monitoring of FRP-strengthened steel structures with extensive application prospects. PMID:29053614

  10. Development of ductile hybrid fiber reinforced polymer (D-H-FRP) reinforcement for concrete structures

    NASA Astrophysics Data System (ADS)

    Somboonsong, Win

    The corrosion of steel rebars has been the major cause of the reinforced concrete deterioration in transportation structures and port facilities. Currently, the Federal Highway Administration (FHWA) spends annually $31 billion for maintaining and repairing highways and highway bridges. The study reported herein represents the work done in developing a new type of reinforcement called Ductile Hybrid Fiber Reinforced Polymer or D-H-FRP using non-corrosive fiber materials. Unlike the previous FRP reinforcements that fail in a brittle manner, the D-H-FRP bars exhibit the stress-strain curves that are suitable for concrete reinforcement. The D-H-FRP stress-strain curves are linearly elastic with a definite yield point followed by plastic deformation and strain hardening resembling that of mild steel. In addition, the D-H-FRP reinforcement has integrated ribs required for concrete bond. The desirable mechanical properties of D-H-FRP reinforcement are obtained from the integrated design based on the material hybrid and geometric hybrid concepts. Using these concepts, the properties can be tailored to meet the specific design requirements. An analytical model was developed to predict the D-H-FRP stress-strain curves with different combination of fiber materials and geometric configuration. This model was used to optimize the design of D-H-FRP bars. An in-line braiding-pultrusion manufacturing process was developed at Drexel University to produce high quality D-H-FRP reinforcement in diameters that can be used in concrete structures. A series of experiments were carried out to test D-H-FRP reinforcement as well as their individual components in monotonic and cyclic tensile tests. Using the results from the tensile tests and fracture analysis, the stress-strain behavior of the D-H-FRP reinforcement was fully characterized and explained. Two series of concrete beams reinforced with D-H-FRP bars were studied. The D-H-FRP beam test results were then compared with companion steel reinforced concrete beams having the same ultimate strength. All D-H-FRP reinforced concrete beams show consistent performance with ultimate strengths and ductility similar to the steel reinforced control specimens and to theoretical predictions.

  11. Tensile strength and water absorption of alumina filled poly (methyl methacrylate) denture base material.

    PubMed

    Nizam, A; Mohamed, S H; Arifin, A; Mohd Ishak, Z A; Samsudin, A R

    2004-05-01

    The aim of this study was to evaluate the tensile properties and water absorption of denture base material prepared from high molecular weight poly methyl methacrylate (PMMA) and alumina (Al2O3) as particulate filler. Specimens for mechanical testing were prepared by adding composite powder to the monomer followed by hand mixing as in dental laboratory procedure. The tensile strength of the prepared denture base material was slightly higher than commercial denture base material, while the water absorption was almost the same for all formulation of denture base materials.

  12. Accelerating effects of cellulase in the removal of denture adhesives from acrylic denture bases.

    PubMed

    Harada-Hada, Kae; Mimura, Sumiyo; Hong, Guang; Hashida, Tatsumi; Abekura, Hitoshi; Murata, Hiroshi; Nishimura, Masahiro; Nikawa, Hiroki

    2017-04-01

    Studies of effective methods for the easy removal of denture adhesives from a denture base are not well represented in the literature. We previously assessed the removability of denture adhesives by immersing within denture cleaners, showing that some cleaners have a weak effect, insufficiently effective in daily use. In this study, we prepared a cellulase, as a potential component for denture adhesive removers, and we examined whether the addition of cellulase to denture cleaners is effective in the removal of cream denture adhesives. We prepared the cellulase Meicelase as one component for the liquefaction of denture adhesives. We used two denture cleaners and two cream adhesives. After the immersion of plates in sample solutions, we evaluated the area of the sample plate still covered with adhesives. Biofilm removal assay was also performed using denture cleaners containing cellulase. The addition of cellulase accelerated the removal of cream adhesives in immersion experiments to a rate faster than that of water and denture cleaners. However, it did not influence the removability of Candida albicans biofilms from acrylic resin specimens. Cellulase hastened the liquefaction of cream adhesives. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Strategic sensor locations of FPR bridge decks

    NASA Astrophysics Data System (ADS)

    Wu, Hwai-Chung; Warnemuende, Kraig; Yan, An; Mu, Bin

    2003-07-01

    Advanced fiber-reinforced polymer composite (FRP) has been increasingly used in bridge deck to replace concrete or steel. A FRP bridge deck can be designed to meet AASHTO HS-25 load requirements. FRP decks have many advantages over the conventional reinforced concrete or steel decks owing to their lightweight, high strength and corrosion resistance. However, such new deck system requires extensive monitoring to ensure its designed performance before its widespread acceptance by the bridge community. For inspection and evaluation purpose, a proper monitoring system consisting of various kinds of sensors installed in the FRP deck is critical. This paper provides a framework for designing an efficient monitoring system. The strategic sensor locations are identified based on the stress analysis of the FRP deck.

  14. Contribution of the palate to denture base support: an in vivo study.

    PubMed

    Ando, Takanori; Maeda, Yoshinobu; Wada, Masahiro; Gonda, Tomoya

    2014-01-01

    The aim of this study was to examine the contribution of the palate to denture base support. Four subjects with tooth- or implant-supported maxillary overdentures were enrolled. Recordings (strain values converted to load values) were performed using miniature strain gauges and force transducers for the following conditions: metal framework only (A), denture base with full palatal coverage (B), and denture base without palatal coverage (C). The palatal-supporting ratio (PSR) was calculated using the equation PSR = (B - C) / A. The PSR values were less than 10% in all subjects, suggesting that the palate plays a minimal role in denture base support.

  15. The use of natural teeth in overlay dentures.

    PubMed

    Frantz, W R

    1975-08-01

    A method has been described for the construction of tooth-supported dentures where the natural tooth was utilized and the acrylic resin for the denture base processed directly to the prepared cast. Based on the 112 dentures that were made, this technique is economical, provides support and stabilization, and has full patient acceptance.

  16. Investigation of rectangular concrete columns reinforced or prestressed with fiber reinforced polymer (FRP) bars or tendons

    NASA Astrophysics Data System (ADS)

    Choo, Ching Chiaw

    Fiber reinforced polymer (FRP) composites have been increasingly used in concrete construction. This research focused on the behavior of concrete columns reinforced with FRP bars, or prestressed with FRP tendons. The methodology was based the ultimate strength approach where stress and strain compatibility conditions and material constitutive laws were applied. Axial strength-moment (P-M) interaction relations of reinforced or prestressed concrete columns with FRP, a linearly-elastic material, were examined. The analytical results identified the possibility of premature compression and/or brittle-tension failure occurring in FRP reinforced and prestressed concrete columns where sudden and explosive type failures were expected. These failures were related to the rupture of FRP rebars or tendons in compression and/or in tension prior to concrete reaching its ultimate strain and strength. The study also concluded that brittle-tension failure was more likely to occur due to the low ultimate tensile strain of FRP bars or tendons as compared to steel. In addition, the failures were more prevalent when long term effects such as creep and shrinkage of concrete, and creep rupture of FRP were considered. Barring FRP failure, concrete columns reinforced with FRP, in some instances, gained significant moment resistance. As expected the strength interaction of slender steel or FRP reinforced concrete columns were dependent more on column length rather than material differences between steel and FRP. Current ACI minimum reinforcement ratio for steel (rhomin) reinforced concrete columns may not be adequate for use in FRP reinforced concrete columns. Design aids were developed in this study to determine the minimum reinforcement ratio (rhof,min) required for rectangular reinforced concrete columns by averting brittle-tension failure to a failure controlled by concrete crushing which in nature was a less catastrophic and more gradual type failure. The proposed method using rhof,min enabled the analysis of FRP reinforced concrete columns to be carried out in a manner similar to steel reinforced concrete columns since similar provisions in ACI 318 were consistently used in developing these aids. The design aids produced accurate estimates of rhof,min. When creep and shrinkage effects of concrete were considered, conservative rhof,min values were obtained in order to preserve an adequate margin of safety due to their unpredictability.

  17. Retention of denture bases fabricated by three different processing techniques – An in vivo study

    PubMed Central

    Chalapathi Kumar, V. H.; Surapaneni, Hemchand; Ravikiran, V.; Chandra, B. Sarat; Balusu, Srilatha; Reddy, V. Naveen

    2016-01-01

    Aim: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. Materials and Methods: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. Results: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. Conclusions: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique. PMID:27382542

  18. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with the oral tissues. After the denture base is constructed, the connected preformed teeth are...: Evaluation and Testing,’ ” and (2) “OTC Denture Reliners, Repair Kits, and Partially Fabricated Denture Kits...

  19. Estimating Landscape Fire Particulate Matter (PM) Emissions over Southern Africa using MSG-SEVIRI Fire Radiative Power (FRP) and MODIS Aerosol Optical Thickness Observations

    NASA Astrophysics Data System (ADS)

    Mota, Bernardo; Wooster, Martin J.

    2016-04-01

    The approach to estimating landscape fire fuel consumption based on the remotely sensed fire radiative power (FRP) thermal energy release rate, as opposed to burned area, is now relatively widely used in studies of fire emissions, including operationally within the Copernicus Atmosphere Monitoring Service (CAMS). Nevertheless, there are still limitations to the approach, including uncertainties associated with using only the few daily overpasses typically provided by polar orbiting satellite systems, the conversion between FRP and smoke emissions, and the increased likelihood that the more frequent data from geostationary systems fails to detect the (probably highly numerous) smaller (i.e. low FRP) component of a regions fire regime. In this study, we address these limitations to directly estimate fire emissions of Particular Matter (PM; or smoke aerosols) by presenting an approach combining the "bottom-up" FRP observations available every 15 minutes across Africa from the Meteosat Spinning Enhanced Visible and Infrared Imager (SEVIRI) Fire Radiative Product (FRP) processed at the EUMETSAT LSA SAF, and the "top-down" aerosol optical thickness (AOT) measures of the fire plumes themselves as measured by the Moderate-resolution Imaging Spectro-radiometer (MODIS) sensors aboard the Terra (MOD04_L2) and Aqua (MYD04_L2) satellites. We determine PM emission coefficients that relate directly to FRP measures by combining these two datasets, and the use of the almost continuous geostationary FRP observations allows us to do this without recourse to (uncertain) data on wind speed at the (unknown) height of the matching plume. We also develop compensation factors to address the detection limitations of small/low intensity (low FRP) fires, and remove the need to estimate fuel consumption by going directly from FRP to PM emissions. We derive the smoke PM emissions coefficients per land cover class by comparing the total fire radiative energy (FRE) released from individual fires and the MODIS AOD seen in the corresponding plume. Analysis was performed for plumes extracted from 31 study sites covering 10,000km2each, during 10 consecutive days, for the 2011 southern Africa fire season. Compensation factors associated with undetected low FRP fires was based on extraction and application of frequency density function shape parameters, characterized by analyzing 4 years (2009-2013) of MSG-SEVIRI FRP data in 0.5o degree cells. Using the derived emission coefficients and compensation factors we estimate Total Particulate Matter (TPM) emissions for 2011 on a daily basis and 0.25o spatial resolution across southern Africa. Preliminary results show agreement between our derived emission coefficients and those of past studies following similar methods but with MODIS FRP data, and our annual TPM estimate is in reasonable agreement with those of other emission inventories based on burned area approaches. The proposed approach shows strong potential to be applied to other regions, and also to other geostationary satellite FRP products. Once the smoke emissions coefficients have been derived via comparison to the AOD data, the method requires only the FRP data, which is available at very high temporal frequency from geostationary orbit. Therefore our approach can provide near real time smoke emissions estimates which are essential for operational activities such as NRT smoke dispersion modeling and air quality forecasting.

  20. Fire Radiative Power (FRP)-based Emission Factors of PM2.5, CO and NOX for Remote Sensing of Biomass Burning Emissions

    NASA Astrophysics Data System (ADS)

    Karandana Gamalathge, T. D.; Chen, L. W. A.

    2015-12-01

    Large-scale biomass burning such as forest fires represents an important and yet uncertain source of air pollutants and greenhouse gases on a global scale. Due to the highly accidental nature of forest fires, satellite remote sensing could be a promising method to develop regional and global fire emission inventories on a real-time basis. Reliable fire radiative power (FRP)-based fuel consumption and emission factors are critical in this approach. In an attempt to obtain the information, laboratory combustion experiments were conducted to simultaneously monitor FRP, fuel consumption, and emissions of fine particulate matter (PM2.5), carbon monoxide (CO), and reactive nitrogen oxides (NO and NO2). FRP were quantified using temperature-resolved values from a thermal imager instead of conventionally used average temperature, as the former provides more realistic estimates. For dry Ponderosa pine branches, a common fuel in the Sierra Nevada, a strong correlation (r2 ~ 0.8) between FRP and the mass reduction rate (MRR) was found. This led to a radiative energy yield (REY) of 8.5 ± 1.2 MJ/kg, assuming blackbody radiation and a flame emissivity of 0.5. Mass-based emission factors were determined with the carbon balance approach. Considering the ratio of mass-based emission factors and the REY, FRP-based emission factors: PM2.5: 11 g/MJ, CO: 8.0 g/MJ, NO: 0.33 g/MJ, and NO2: 0.07 g/MJ were quantified. The application of this approach to other fuel types and uncertainties in the measurements will be discussed.

  1. Comparative evaluation of the effect of denture cleansers on the surface topography of denture base materials: An in-vitro study.

    PubMed

    Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N S

    2015-08-01

    The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. The values obtained were analyzed statistically using one-way ANOVA and paired t-test. All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased.

  2. Comparative evaluation of the effect of denture cleansers on the surface topography of denture base materials: An in-vitro study

    PubMed Central

    Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N. S.

    2015-01-01

    Aims: The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Materials and Methods: Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. Statistical Analysis Used: The values obtained were analyzed statistically using one-way ANOVA and paired t-test. Results: All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Conclusion: Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased. PMID:26538915

  3. Effect of biofilm formation, and biocorrosion on denture base fractures.

    PubMed

    Sahin, Cem; Ergin, Alper; Ayyildiz, Simel; Cosgun, Erdal; Uzun, Gulay

    2013-05-01

    The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (α=0.05). Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P<.05); microorganisms diffused at least 52% of the denture base surface. The highest median quantitative biofilm value within all the denture base materials was obtained with P. aeruginosa on Lucitone 550. The type of denture base material did not alter the diffusion potential of the microorganisms significantly (P>.05). All the tested microorganisms had destructive effect over the structure and composition of the denture base materials.

  4. Effect of biofilm formation, and biocorrosion on denture base fractures

    PubMed Central

    Ergin, Alper; Ayyildiz, Simel; Cosgun, Erdal; Uzun, Gulay

    2013-01-01

    PURPOSE The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. MATERIALS AND METHODS Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (α=0.05). RESULTS Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P<.05); microorganisms diffused at least 52% of the denture base surface. The highest median quantitative biofilm value within all the denture base materials was obtained with P. aeruginosa on Lucitone 550. The type of denture base material did not alter the diffusion potential of the microorganisms significantly (P>.05). CONCLUSION All the tested microorganisms had destructive effect over the structure and composition of the denture base materials. PMID:23755339

  5. 2010 Federal Radionavigation Plan

    DOT National Transportation Integrated Search

    2011-04-15

    The Federal Radionavigation Plan (FRP) reflects the official positioning, : navigation, and timing (PNT) policy and planning for the Federal : Government. The FRP covers both terrestrial- and space-based, commonuse, : federally operated PNT systems. ...

  6. Effect of potentially chromogenic beverages on shear bond strength of acrylic denture teeth to heat-polymerized denture base resins

    PubMed Central

    Neppelenbroek, Karin Hermana; Urban, Vanessa Migliorini; de Oliveira, Denise Gusmão; Porto, Vinícius Carvalho; Almilhatti, Hercules Jorge; Campanha, Nara Hellen

    2016-01-01

    Background: Detachment of denture acrylic resin artificial teeth from denture base resin is one of the most common problems presented by denture wearers. Purpose: This study investigated the shear bond strength (SBS) and fracture type of bonding interface of two commercial acrylic teeth (Vipi Dent Plus e Biolux) to two denture base resins (Vipi Cril e Lucitone 550) after immersion in potentially chromogenic beverages (coffee, cola soft drink, and red wine) or control solution (distilled water). Materials and Methods: Maxillary central incisor acrylic teeth were placed at 45° to denture base resin and submitted to short polymerization cycle according to manufacturers. Specimens were divided according to the combination tooth/resin/solution (n = 8) and submitted to bond strength tests in a universal testing machine MTS-810 (0.5 mm/min). Subsequently, fracture area was analyzed by stereomicroscope at a magnification of ×10 and categorized into adhesive, cohesive, or mixed failure. Results: The bond strength of teeth/denture base resins interface was not significantly affected by tested solutions (P > 0.087), except for Biolux teeth immersed in coffee (P < 0.01). In all conditions, the Vipi Dent Plus teeth showed higher bond strength to Lucitone and Vipi Cril resins when compared to Biolux teeth (P < 0.003). All specimens’ failure modes were cohesive. Conclusions: The SBS of acrylic teeth to denture base resins was not generally influenced by immersion in the tested staining beverages. PMID:27621547

  7. Development of Dietary Polyphenol Preparations for Treating Veterans with Gulf War Illness

    DTIC Science & Technology

    2015-10-01

    chronic fatigue. We hypothesized that dietary supplementation with a Flavonoid- Rich Preparation (FRP), a combination of Concord Grape Juice (CGJ...We propose to test the feasibility of dietary supplementation with FRP in Veterans with GWI, and to gather evidence supporting the efficacy of FRP...fatigue and preserve against cognitive functions. Based on this, our overall goal is to test the potential efficacy of dietary supplementation with a

  8. Distributed Long-Gauge Optical Fiber Sensors Based Self-Sensing FRP Bar for Concrete Structure

    PubMed Central

    Tang, Yongsheng; Wu, Zhishen

    2016-01-01

    Brillouin scattering-based distributed optical fiber (OF) sensing technique presents advantages for concrete structure monitoring. However, the existence of spatial resolution greatly decreases strain measurement accuracy especially around cracks. Meanwhile, the brittle feature of OF also hinders its further application. In this paper, the distributed OF sensor was firstly proposed as long-gauge sensor to improve strain measurement accuracy. Then, a new type of self-sensing fiber reinforced polymer (FRP) bar was developed by embedding the packaged long-gauge OF sensors into FRP bar, followed by experimental studies on strain sensing, temperature sensing and basic mechanical properties. The results confirmed the superior strain sensing properties, namely satisfied accuracy, repeatability and linearity, as well as excellent mechanical performance. At the same time, the temperature sensing property was not influenced by the long-gauge package, making temperature compensation easy. Furthermore, the bonding performance between self-sensing FRP bar and concrete was investigated to study its influence on the sensing. Lastly, the sensing performance was further verified with static experiments of concrete beam reinforced with the proposed self-sensing FRP bar. Therefore, the self-sensing FRP bar has potential applications for long-term structural health monitoring (SHM) as embedded sensors as well as reinforcing materials for concrete structures. PMID:26927110

  9. Distributed Long-Gauge Optical Fiber Sensors Based Self-Sensing FRP Bar for Concrete Structure.

    PubMed

    Tang, Yongsheng; Wu, Zhishen

    2016-02-25

    Brillouin scattering-based distributed optical fiber (OF) sensing technique presents advantages for concrete structure monitoring. However, the existence of spatial resolution greatly decreases strain measurement accuracy especially around cracks. Meanwhile, the brittle feature of OF also hinders its further application. In this paper, the distributed OF sensor was firstly proposed as long-gauge sensor to improve strain measurement accuracy. Then, a new type of self-sensing fiber reinforced polymer (FRP) bar was developed by embedding the packaged long-gauge OF sensors into FRP bar, followed by experimental studies on strain sensing, temperature sensing and basic mechanical properties. The results confirmed the superior strain sensing properties, namely satisfied accuracy, repeatability and linearity, as well as excellent mechanical performance. At the same time, the temperature sensing property was not influenced by the long-gauge package, making temperature compensation easy. Furthermore, the bonding performance between self-sensing FRP bar and concrete was investigated to study its influence on the sensing. Lastly, the sensing performance was further verified with static experiments of concrete beam reinforced with the proposed self-sensing FRP bar. Therefore, the self-sensing FRP bar has potential applications for long-term structural health monitoring (SHM) as embedded sensors as well as reinforcing materials for concrete structures.

  10. Do CAD/CAM dentures really release less monomer than conventional dentures?

    PubMed

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  11. Elimination of deck joints using a corrosion resistant FRP approach

    NASA Astrophysics Data System (ADS)

    Aleti, Ashok Reddy

    The research presented herein describes the development of durable link slabs for jointless bridge decks based on using FRP grid for reinforcement. Specifically, the ductility of the FRP material was utilized to accommodate bridge deck deformations imposed by girder deflection, temperature variations, and concrete shrinkage. It would also provide a solution to a number of deterioration problems associated with bridge deck joints. The design concept of the link slabs was then examined to form the basis of design for FRP grid link slabs. Improved design of FRP grid link slab/concrete deck slab interface was confirmed in the numerical analysis. The mechanical properties between the FRP grid and concrete were evaluated. The behavior of the link slab was investigated and confirmed for durability. The results indicated that the technique would allow simultaneous achievement of structural need (lower flexural stiffness of the link slab approaching the behavior of a hinge) and durability need of the link slab. Also, the development length results confirm that the bond between the FRP grid and the concrete was highly improved. The overall investigation supports the contention that durable jointless concrete bridge decks may be designed and constructed with FRP grid link slabs. It is recommended that the link slab technique be used during new construction of the bridge decks and in repair and retrofit of the bridge decks.

  12. [The paper summarizes data on laboratory and clinical assessment of Corega dent Laboratory and clinical analysis of Corega denture adhesive cream mechanical properties].

    PubMed

    Kalivradzhiyan, E S; Podoprigora, A V; Kaverina, E Yu; Bobeshko, M N

    The paper summarizes data on laboratory and clinical assessment of Corega denture adhesive cream adhesive properties: adhesion strength and time of adhesive material fixing. Clinical assessment was based on Ulitovsky-Leontyev denture fixation index evaluated in 18 edentulous patients with full removable dentures 1 and 12 months after denture manufacturing. After one year of evaluation denture fixation in patients using Corega denture adhesive cream was 8-15% better (depending on alveolar bed anatomy) than in controls proving that Corega improves full denture adaptation to physiological atrophy of alveolar bone.

  13. Pultruded composites using soy-based polyurethane resin.

    DOT National Transportation Integrated Search

    2008-07-01

    Fiber Reinforced Polymer (FRP) composites offer inherent advantages over traditional materials with regard to high strength-to-weight ratio, design flexibility, corrosion resistance, low maintenance, and extended service life. FRP materials can be us...

  14. Failure strengths of denture teeth fabricated on injection molded or compression molded denture base resins.

    PubMed

    Robison, Nathan E; Tantbirojn, Daranee; Versluis, Antheunis; Cagna, David R

    2016-08-01

    Denture tooth fracture or debonding remains a common problem in removable prosthodontics. The purpose of this in vitro study was to explore factors determining failure strengths for combinations of different denture tooth designs (shape, materials) and injection or compression molded denture base resins. Three central incisor denture tooth designs were tested: nanohybrid composite (NHC; Ivoclar Phonares II), interpenetrating network (IPN; Dentsply Portrait), and microfiller reinforced polyacrylic (MRP; VITA Physiodens). Denture teeth of each type were processed on an injection molded resin (IvoBase HI; Ivoclar Vivadent AG) or a compression molded resin (Lucitone 199; Dentsply Intl) (n=11 or 12). The denture teeth were loaded at 45 degrees on the incisal edge. The failure load was recorded and analyzed with 2-way ANOVA (α=.05), and the fracture mode was categorized from observed fracture surfaces as cohesive, adhesive, or mixed failure. The following failure loads (mean ±SD) were recorded: NHC/injection molded 280 ±52 N; IPN/injection molded 331 ±41 N; MRP/injection molded 247 ±23 N; NHC/compression molded 204 ±31 N; IPN/compression molded 184 ±17 N; MRP/compression molded 201 ±16 N. Injection molded resin yielded significantly higher failure strength for all denture teeth (P<.001), among which IPN had the highest strength. Failure was predominantly cohesive in the teeth, with the exception of mixed mode for the IPN/compression group. When good bonding was achieved, the strength of the structure (denture tooth/base resin combination) was determined by the strength of the denture teeth, which may be affected by the processing technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    PubMed Central

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  16. Development of Dietary Polyphenol Preparations for Treating Veterans with Gulf War Illness

    DTIC Science & Technology

    2016-10-01

    chronic fatigue. We hypothesized that dietary supplementation with a Flavonoid Rich Preparation (FRP), a combination of Concord Grape Juice (CGJ) and...We propose to test the feasibility of dietary supplementation with FRP in Veterans with GWI, and to gather evidence supporting the efficacy of FRP in...fatigue and preserve against cognitive functions. Based on this, our overall goal is to test the potential efficacy of dietary supplementation with a

  17. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study.

    PubMed

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-06-01

    The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey's post-hoc test were used for statistical analysis. Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively.

  18. Allergic effects of the residual monomer used in denture base acrylic resins

    PubMed Central

    Rashid, Haroon; Sheikh, Zeeshan; Vohra, Fahim

    2015-01-01

    Denture base resins are extensively used in dentistry for a variety of purposes. These materials can be classified as chemical, heat, light, and microwave polymerization materials depending upon the factor which starts the polymerization reaction. Their applications include use during denture base construction, relining existing dentures, and for fabrication of orthodontic removable appliances. There have been increased concerns regarding the safe clinical application of these materials as their biodegradation in the oral environment leads to harmful effects. Along with local side effects, the materials have certain occupational hazards, and numerous studies can be found in the literature mentioning those. The purpose of this article is to outline the cytotoxic consequences of denture base acrylic resins and clinical recommendations for their use. PMID:26929705

  19. Applications of FRP-OFBG sensors on bridge cables

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Zhang, Zhichun; Deng, Nianchun; Zhao, Xuefeng; Li, Dongsheng; Wang, Chuang; Ou, Jinping

    2005-05-01

    It is still a practical problem how to effectively install FBG sensors on bridge cabes. In this paper, a simple and effective solution is introduced to develop smart bridge cables using FRP-OFBG bars developed in HIT (Harbin Institute of Technology). Here, the FRP-OFBG bar acts as one component of the cable and shows force resistance and well-protected sensors in service. The installation techniques and the sensing properties of FBGs in three kinds of cables, FRP cables, common steel-wire cable and extruded-anchor cable, are introduced and tested under dead load. Moreover, the preliminary introduction of a practical field application based on this solution has been also given. The experimental results show that the deformability of FRP-OFBG bars in the smart cables can reach the terminal and show wonderful accuracy, which shows that such kind of smart cable is practical in field application.

  20. Global Characterization of Biomass-Burning Patterns using Satellite Measurements of Fire Radiative Energy

    NASA Technical Reports Server (NTRS)

    Ichoku, Charles; Giglio, Louis; Wooster, Martin J.; Remer, Lorraine A.

    2008-01-01

    Remote sensing is the most practical means of measuring energy release from large open-air biomass burning. Satellite measurement of fire radiative energy (FRE) release rate or power (FRP) enables distinction between fires of different strengths. Based on a 1-km resolution fire data acquired globally by the MODerate-resolution Imaging Spectro-radiometer (MODIS) sensor aboard the Terra and Aqua satellites from 2000 to 2006, instanteaneous FRP values ranged between 0.02 MW and 1866 MW, with global daily means ranging between 20 and 40 MW. Regionally, at the Aqua-MODIS afternoon overpass, the mean FRP values for Alaska, Western US, Western Australia, Quebec and the rest of Canada are significantly higher than these global means, with Quebec having the overall highest value of 85 MW. Analysis of regional mean FRP per unit area of land (FRP flux) shows that a peak fire season in certain regions, fires can be responsible for up to 0.2 W/m(sup 2) at peak time of day. Zambia has the highest regional monthly mean FRP flux of approximately 0.045 W/m(sup 2) at peak time of day and season, while the Middle East has the lowest value of approximately 0.0005 W/m(sup 2). A simple scheme based on FRP has been devised to classify fires into five categories, to facilitate fire rating by strength, similar to earthquakes and hurricanes. The scheme uses MODIS measurements of FRP at 1-km resolution as follows: catagory 1 (less than 100 MW), category 2 (100 to less than 500 MW), category 3 (500 to less than 1000 MW), category 4 (1000 to less than 1500 MW), catagory 5 (greater than or equal to 1500 MW). In most regions of the world, over 90% of fires fall into category 1, while only less than 1% fall into each of categories 3 to 5, although these proportions may differ significantly from day to day and by season. The frequency of occurence of the larger fires is region specific, and could not be explained by ecosystem type alone. Time-series analysis of the propertions of higher category fires based on MODIS measured FRP from 2002 to 2006 does not show any moticeable trend because of the short time period.

  1. Microwave disinfection of maxillary and mandibular denture bases contaminated with Candida Albican.

    PubMed

    Bamigboye, S A; Dosumu, O O; Ajayi, D M

    2015-09-01

    Oral environment is not sterile, and dentures worn by the patients can be infected and therefore needs disinfection. Solution disinfectants such as sodium hypochlorite and glutaraldehyde can be used but they have side effects. Microwave disinfection method is more recent, however, there are conflicting reports at the moment on the appropriate power and time regimen for disinfection of denture. To determine the power and time regimen at which the disinfection of dentures can be achieved using microwave. Forty-five acrylic denture bases were fabricated for each of the jaws and infected with solution of a stock Candida albicans and 30 infected bases were employed as control. These were placed in normal saline and then subjected to different microwave power and time regimen. Aliquots from these post-microwave solution were titrated against sabauraud agar which was subsequently incubated at 37 degrees C for 48 hours. The agar were examined for candida growth. The denture bases subjected to microwave disinfection at 350W showed Candida growth after microwave treatment irrespective of the time employed. Conversely, those microwaved at 650W and 690W for four and six minutes showed no microbial growth. The microwave regimen of 650W at 4 and 6 minutes completely disinfected the denture bases. Disinfection at higher microwave energy should be done with caution as distortion of the denture may occur.

  2. FRP debonding monitoring using OTDR techniques

    NASA Astrophysics Data System (ADS)

    Hou, Shuang; Cai, C. S. Steve; Ou, Jinping

    2009-07-01

    Debonding failure has been reported as the dominant failure mode for FRP strengthening in flexure. This paper explores a novel debonding monitoring method for FRP strengthened structures by means of OTDR-based fiber optic technology. Interface slip as a key factor in debonding failures will be measured through sensing optic fibers, which is instrumented in the interface between FRP and concrete in the direction perpendicular to the FRP filaments. Slip in the interface will induce power losses in the optic fiber signals at the intersection point of the FRP strip and the sensing optic fiber and the signal change will be detected through OTDR device. The FRP double shear tests and three-point bending tests were conducted to verify the effectiveness of the proposed monitoring method. It is found that the early bebonding can be detected before it causes the interface failure. The sensing optic fiber shows signal changes in the slip value at about 36~156 micrometer which is beyond sensing capacity of the conventional sensors. The tests results show that the proposed method is feasible in slip measurement with high sensitivity, and would be cost effective because of the low price of sensors used, which shows its potential of large-scale applications in civil infrastructures, especially for bridges.

  3. An experimentally based analytical model for the shear capacity of FRP-strengthened reinforced concrete beams

    NASA Astrophysics Data System (ADS)

    Pellegrino, C.; Modena, C.

    2008-05-01

    This paper deals with the shear strengthening of Reinforced Concrete (RC) flexural members with externally bonded Fiber-Reinforced Polymers (FRPs). The interaction between an external FRP and an internal transverse steel reinforcement is not considered in actual code recommendations, but it strongly influences the efficiency of the shear strengthening rehabilitation technique and, as a consequence, the computation of interacting contributions to the nominal shear strength of beams. This circumstance is also discussed on the basis of the results of an experimental investigation of rectangular RC beams strengthened in shear with "U-jacketed" carbon FRP sheets. Based on experimental results of the present and other investigations, a new analytical model for describing the shear capacity of RC beams strengthened according to the most common schemes (side-bonded and "U-jacketed"), taking into account the interaction between steel and FRP shear strength contributions, is proposed.

  4. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study

    PubMed Central

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-01-01

    Background: The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. Materials and Methods: The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey’s post-hoc test were used for statistical analysis. Results: Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Conclusions: Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively. PMID:26124604

  5. Secreted Frizzled-related protein 2 as a target in antifibrotic therapeutic intervention.

    PubMed

    Mastri, Michalis; Shah, Zaeem; Hsieh, Karin; Wang, Xiaowen; Wooldridge, Bailey; Martin, Sean; Suzuki, Gen; Lee, Techung

    2014-03-15

    Progressive fibrosis is a pathological hallmark of many chronic diseases responsible for organ failure. Although there is currently no therapy on the market that specifically targets fibrosis, the dynamic fibrogenic process is known to be regulated by multiple soluble mediators that may be therapeutically intervened. The failing hamster heart exhibits marked fibrosis and increased expression of secreted Frizzled-related protein 2 (sFRP2) amenable to reversal by mesenchymal stem cell (MSC) therapy. Given the previous demonstration that sFRP2-null mice subjected to myocardial infarction exhibited reduced fibrosis and improved function, we tested whether antibody-based sFRP2 blockade might counteract the fibrogenic pathway and repair cardiac injury. Cardiomyopathic hamsters were injected intraperitoneally twice a week each with 20 μg of sFRP2 antibody. Echocardiography, histology, and biochemical analyses were performed after 1 mo. sFRP2 antibody increased left ventricular ejection fraction from 40 ± 1.2 to 49 ± 6.5%, whereas saline and IgG control exhibited a further decline to 37 ± 0.9 and 31 ± 3.2%, respectively. Functional improvement is associated with a ∼ 50% reduction in myocardial fibrosis, ∼ 65% decrease in apoptosis, and ∼ 75% increase in wall thickness. Consistent with attenuated fibrosis, both MSC therapy and sFRP2 antibody administration significantly increased the activity of myocardial matrix metalloproteinase-2. Gene expression analysis of the hamster heart and cultured fibroblasts identified Axin2 as a downstream target, the expression of which was activated by sFRP2 but inhibited by therapeutic intervention. sFRP2 blockade also increased myocardial levels of VEGF and hepatocyte growth factor (HGF) along with increased angiogenesis. These findings highlight the pathogenic effect of dysregulated sFRP2, which may be specifically targeted for antifibrotic therapy.

  6. A new concept in denture design for patients with few remaining teeth: case reports.

    PubMed

    Ling, B C

    1995-12-01

    This article presents an alternative to the conventional swing-lock de sign of removable partial denture construction. It incorporates the principles of sectional dentures as well as the swing-lock concept and overcomes some of the limitations of conventional swing-lock dentures. I-bar struts and stainless steel keepers form part of the first section of the denture. The second part of the denture consists of the denture base with the artificial teeth and magnetic retention units. This system has been used successfully in a number of patients whose situations were suitable for the conventional swing-lock design.

  7. FRCM and FRP composites for the repair of damaged PC girders.

    DOT National Transportation Integrated Search

    2015-01-01

    Fabric-reinforced-cementitious-matrix (FRCM) and fiber-reinforced polymer (FRP) composites have : emerged as novel strengthening technologies. FRCM is a composite material consisting of a sequence of : one or more layers of cement-based matrix reinfo...

  8. Function of fusion regulatory proteins (FRPs) in immune cells and virus-infected cells.

    PubMed

    Tsurudome, M; Ito, Y

    2000-01-01

    Two molecules that regulate cell fusion have been identified and designated fusion regulatory protein-1 (FRP-1) and FRP-2. FRP-1 is a complex composed of a glycosylated heavy chain and a nonglycosylated light chain that are disulfide linked. FRP-1 heavy chain is identical to 4F2/CD98 heavy chain, whereas FRP-2 is identical to integrin alpha3 subunit. The FRP-1 heavy chain is a multifunctional molecule: that is, fusion regulator, amino acid transporter, integrin regulator, comitogenic factor, Na+-Ca2+ exchanger, oncogenic protein, and so on. Several aspects of the structure and function of the FRP-1 system are reviewed: fusion regulatory molecular mechanisms, cross-talk between the FRP-1 and integrin, the FRP-1 system as amino acid transporter, and FRP-1-mediated T-cell activation. The FRP-1 system is involved in virus-mediated cell fusion and multinucleated giant cell formation of blood monocytes. Monoclonal antibodies against human FRP-1 heavy chain induce polykaryocytes that have properties as osteoclasts. Multiple steps participate in molecular mechanisms regulating cell fusion. The FRP-1 heavy chain supports amino acid transport activity and the FRP-1 light chains have recently been cloned as amino acid transporters that require association with the heavy chain to exhibit their activity. Novel pathways for monocyte-dependent regulation of T-cell activation have recently been found that are mediated by the FRP-1 system. In conclusion, the FRP-1 molecules are essential factors for basic cellular functions.

  9. Residual methyl methacrylate monomer, water sorption, and water solubility of hypoallergenic denture base materials.

    PubMed

    Pfeiffer, Peter; Rosenbauer, Ernst-Ulrich

    2004-07-01

    Denture base materials have the potential to cause irritation and allergic reaction to the oral mucosa. Water sorption and water solubility of denture base resins affect dimensional behavior and denture stability. A correlation between residual monomer and water sorption exists. This in vitro study compared the amount of residual monomer, quantity of water sorption, and solubility of 4 denture base materials purported to be hypoallergenic with those of a polymethyl methacrylate-based (PMMA) heat-polymerizing acrylic resin. The denture base resins Sinomer (heat-polymerized, modified methacrylate), Polyan (thermoplastic, modified methacrylate), Promysan (thermoplastic, enterephthalate-based), and Microbase (microwave polymerized, polyurethane-based), which are purported to be hypoallergenic, and Paladon 65 (heat-polymerized, methacrylate, control group) were examined. Specimens of each material were tested for residual methyl methacrylate (MMA) monomer (% wt, n=3), amount of water sorption (microg/mm3, n=5) and water solubility (microg/mm3, n=5), according to ISO 1567:2000. The residual MMA monomer concentrations were determined by gas chromatography (GC). The data were analyzed with 1-way ANOVA and the Bonferroni-Dunn multiple comparisons post hoc analysis for each test variable (alpha=.05). Significantly lower residual MMA monomer was shown for Sinomer and Polyan compared to the PMMA control group (0.90 +/- 0.20% wt, P<.05). Sinomer contained 0.31% +/- 0.00% wt MMA monomer, and Polyan exhibited residual MMA monomer content of 0.44% +/- 0.01% wt. Promysan and Microbase did not contain detectable residual MMA. Water sorption of Promysan (16.21 +/- 0.96 microg/mm3) was significantly lower than Paladon 65 (23.04 +/- 3.13 microg/mm3, P<.0001), whereas water solubility of the hypoallergenic denture base materials (0.34-0.84 +/- 0.05-0.09 microg/mm3) was not significantly lower than the PMMA material (0.40 +/- 0.06 microg/mm3, P>.05). Except for Sinomer, the tested denture base resins passed the requirements of ISO 1567 regarding residual MMA monomer (<2.2% wt). Sinomer failed to comply with the requirements for residual MMA monomer because the manufacturer claimed that the material did not contain any MMA. The tested denture base materials fulfilled the requirements regarding water sorption (<32 microg/mm3) and solubility (<1.6 microg/mm3). The tested hypoallergenic denture base materials exhibited significantly lower residual monomer content than PMMA. Promysan and Microbase showed no detectable residual MMA.

  10. LSA SAF Meteosat FRP Products: Part 2 - Evaluation and demonstration of use in the Copernicus Atmosphere Monitoring Service (CAMS)

    NASA Astrophysics Data System (ADS)

    Roberts, G.; Wooster, M. J.; Xu, W.; Freeborn, P. H.; Morcrette, J.-J.; Jones, L.; Benedetti, A.; Kaiser, J.

    2015-06-01

    Characterising the dynamics of landscape scale wildfires at very high temporal resolutions is best achieved using observations from Earth Observation (EO) sensors mounted onboard geostationary satellites. As a result, a number of operational active fire products have been developed from the data of such sensors. An example of which are the Fire Radiative Power (FRP) products, the FRP-PIXEL and FRP-GRID products, generated by the Land Surface Analysis Satellite Applications Facility (LSA SAF) from imagery collected by the Spinning Enhanced Visible and Infrared Imager (SEVIRI) on-board the Meteosat Second Generation (MSG) series of geostationary EO satellites. The processing chain developed to deliver these FRP products detects SEVIRI pixels containing actively burning fires and characterises their FRP output across four geographic regions covering Europe, part of South America and northern and southern Africa. The FRP-PIXEL product contains the highest spatial and temporal resolution FRP dataset, whilst the FRP-GRID product contains a spatio-temporal summary that includes bias adjustments for cloud cover and the non-detection of low FRP fire pixels. Here we evaluate these two products against active fire data collected by the Moderate Resolution Imaging Spectroradiometer (MODIS), and compare the results to those for three alternative active fire products derived from SEVIRI imagery. The FRP-PIXEL product is shown to detect a substantially greater number of active fire pixels than do alternative SEVIRI-based products, and comparison to MODIS on a per-fire basis indicates a strong agreement and low bias in terms of FRP values. However, low FRP fire pixels remain undetected by SEVIRI, with errors of active fire pixel detection commission and omission compared to MODIS ranging between 9-13 and 65-77% respectively in Africa. Higher errors of omission result in greater underestimation of regional FRP totals relative to those derived from simultaneously collected MODIS data, ranging from 35% over the Northern Africa region to 89% over the European region. High errors of active fire omission and FRP underestimation are found over Europe and South America, and result from SEVIRI's larger pixel area over these regions. An advantage of using FRP for characterising wildfire emissions is the ability to do so very frequently and in near real time (NRT). To illustrate the potential of this approach, wildfire fuel consumption rates derived from the SEVIRI FRP-PIXEL product are used to characterise smoke emissions of the 2007 Peloponnese wildfires within the European Centre for Medium-Range Weather Forecasting (ECMWF) Integrated Forecasting System (IFS), as a demonstration of what can be achieved when using geostationary active fire data within the Copernicus Atmosphere Monitoring System (CAMS). Qualitative comparison of the modelled smoke plumes with MODIS optical imagery illustrates that the model captures the temporal and spatial dynamics of the plume very well, and that high temporal resolution emissions estimates such as those available from geostationary orbit are important for capturing the sub-daily variability in smoke plume parameters such as aerosol optical depth (AOD), which are increasingly less well resolved using daily or coarser temporal resolution emissions datasets. Quantitative comparison of modelled AOD with coincident MODIS and AERONET AOD indicates that the former is overestimated by ∼ 20-30%, but captures the observed AOD dynamics with a high degree of fidelity. The case study highlights the potential of using geostationary FRP data to drive fire emissions estimates for use within atmospheric transport models such as those currently implemented as part of the Monitoring Atmospheric Composition and Climate (MACC) programme within the CAMS.

  11. Inhibitory effects of Lactobacillus rhamnosus and Lactobacillus casei on Candida biofilm of denture surface.

    PubMed

    Song, Young-Gyun; Lee, Sung-Hoon

    2017-04-01

    Candida albicans biofilm is associated with denture-related stomatitis and oral candidiasis of elderly. Probiotics are beneficial bacteria and have antibacterial activity against pathogenic bacteria. The purpose of this study was to investigate the antifungal activity of various probiotics against C. albicans and the inhibitory effects of probiotics on Candida biofilm on the denture surface. The spent culture media of various probiotics were investigated the antifungal efficacy against C. albicans. Candida biofilm was formed on a denture base resin and was then treated with Lactobacillus rhamnosus and Lactobacillus casei. Also, the biofilms of L. rhamnosus and L. casei were formed and were sequentially treated with C. albicans. Colony-forming units of C. albicans on the denture surface were counted after spreading on agar plate. The denture base resin was treated with the spent culture media for 30days, after which the denture surface roughness was analyzed with an atomic force microscope. L. rhamnosus and L. casei exhibited stronger antifungal activity than other probiotics. The spent culture medium of L. rhamnosus and L. casei exhibited the antifungal activity against blastoconidia and biofilm of C. albicans. L. rhamnosus and L. casei showed the antifungal activity against Candida biofilm, and the biofilm of L. rhamnosus and L. casei inhibited formation of Candida biofilm on denture surface. Neither of the probiotics affected the surface roughness of the denture base resin. L. rhamnosus and L. casei may be the ideal probiotics for the prevention and treatment of denture-related stomatitis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Experimental investigation of RC beams using BOTDA(R)-FRP-OF

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; He, Jianping; Huang, Ying; Ou, Jinping

    2008-04-01

    Brillouin based fiber optic sensing turns to be a promising technology for Structural Health Monitoring (SHM). However, the bare optical fiber is too fragile to act as a practical sensor, so high durability and large range (large strain) Brillouin distributed sensors are in great needs in field applications. For this reason, high durable and large range optical fiber Brillouin Optical Time Domain Analysis (Reflectometer) sensors packaged by Fiber Reinforcement Polymer (FRP), named BOTDA(R)-FRP-OF, have been studied and developed. Besides, in order to study the large strain, crack and slip between the rebar and concrete in reinforced concrete (RC) beams using BOTDR(A) technique, five RC Beams installed with BOTDA(R)-FRP-OF sensors have been set up. And the damage characteristics of the RC beams were investigated by comparing the strain measured by the BOTDA(R)-FRP-OF sensors and the strain from traditional electric strain gauges and Fiber Bragg Grating (FBG) sensors, respectively. The test results show that the BOTDA(R)-FRP-OF sensor can effectively detect the damage (including crack and slip) characteristic of RC beam, and it is suitable for the long-term structural health monitoring on concrete structures such as bridge, big dam and so on.

  13. Study on RC beams using BOTDA(R)-FRP-OF technique

    NASA Astrophysics Data System (ADS)

    He, Jianping; Zhou, Zhi; Huang, Ying; Ou, Jinping

    2008-03-01

    Brillouin based fiber optic sensing turns to be a promising technology for Structural Health Monitoring (SHM). However, the bare optical fiber is too fragile to act as a practical sensor, so high durability and large range (large strain) Brillouin distributed sensors are in great needs in field applications. For this reason, high durable and large range optical fiber Brillouin Optical Time Domain Analysis sensors packaged by Fiber Reinforcement Polymer (FRP), named BOTDA(R)-FRP-OF, have been studied and developed. Besides, in order to study the large strain, crack and slip between the rebar and concrete in reinforced concrete (RC) beams using BOTDR(A) technique, two RC Beams installed with BOTDA(R)-FRP-OF sensors have been set up. And the damage characteristics of the RC beams were investigated by comparing the strain measured by the BOTDA(R)-FRP-OF sensors and the strain from traditional electric strain gauges. The test results show that the BOTDA(R)-FRP-OF sensor can effectively detect the damage (including crack and slip) characteristic of RC beam, and it is suitable for the long-term structural health monitoring on concrete structures such as bridge, big dam and so on.

  14. An investigation into the impact of cryogenic environment on mechanical stresses in FRP composites

    NASA Astrophysics Data System (ADS)

    Fifo, O.; Basu, B.

    2015-07-01

    Fibre reinforced polymer (FRP) composites are fast becoming a highly utilised engineering material for high performance applications due to their light weight and high strength. Carbon fibre and other high strength fibres are commonly used in design of aerospace structures, wind turbine blades, etc. and potentially for propellant tanks of launch vehicles. For the aforementioned fields of application, stability of the material is essential over a wide range of temperature particularly for structures in hostile environments. Many studies have been conducted, experimentally, over the last decade to investigate the mechanical behaviour of FRP materials at varying subzero temperature. Likewise, tests on aging and cycling effect (room to low temperature) on the mechanical response of FRP have been reported. However, a relatively lesser focused area has been the mechanical behaviour of FRP composites under cryogenic environment. This article reports a finite element method of investigating the changes in the mechanical characteristics of an FRP material when temperature based analysis falls below zero. The simulated tests are carried out using a finite element package with close material properties used in the cited literatures. Tensile test was conducted and the results indicate that the mechanical responses agree with those reported in the literature sited.

  15. Effect of surface treatments on shear bond strength of denture teeth to denture base resins

    PubMed Central

    Bahrani, Farideh; Khaledi, Amir Ali Reza

    2014-01-01

    Background: Debonding of denture teeth from denture bases is the most common failure in removable dentures. The purpose of this study was to evaluate the effect of surface treatments on shear bond strength of denture teeth to heat-polymerized and autopolymerized denture base resins. Materials and Methods: In this experimental in vitro study, 60 maxillary central incisor acrylic teeth were divided into two groups. Group M was polymerized with heat-polymerized acrylic resin (Meliodent) by compression molding technique and group F was processed by autopolymerized acrylic resin (Futura Gen) by injection molding technique. Within each group, specimens were divided into three subgroups according to the teeth surface treatments (n = 10): (1) ground surface as the control group (M1 and F1), (2) ground surface combined with monomer application (M2 and F2), and (3) airborne particle abrasion by 50 μm Al2O3 (M3 and F3). The shear bond strengths of the specimens were tested by universal testing machine with crosshead speed of 5 mm/min. Data were analyzed by two-way analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD) tests (P < 0.05). Results: The mean shear bond strengths of the studied groups were 96.40 ± 14.01, 124.70 ± 15.64, and 118 ± 16.38 N for M1, M2, and M3 and 87.90 ± 13.48, 117 ± 13.88, and 109.70 ± 13.78 N for F1, F2, and F3, respectively. The surface treatment of the denture teeth significantly affected their shear bond strengths to the both the denture base resins (P < 0.001). However, there were no significant differences between the groups treated by monomer or airborne particle abrasion (P = 0.29). The highest percentage of failure mode was mixed in Meliodent and adhesive in Futura Gen. Conclusion: Monomer application and airborne particle abrasion of the ridge lap area of the denture teeth improved their shear bond strengths to the denture base resins regardless of the type of polymerization. PMID:24688570

  16. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Bactericidal efficacy of glycine-type amphoteric surfactant as a denture cleaner and its influence on properties of denture base resins.

    PubMed

    Hashiguchi, Makiko; Nishi, Yasuhiro; Kanie, Takahito; Ban, Seiji; Nagaoka, Eiichi

    2009-05-01

    The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before and after cleaning in Gly solutions, a commercial denture cleaner, and tap water. The microorganism removal rates of all the Gly solutions were higher than those of a commercial enzymatic denture cleaner (Polident) (p>0.05). The removal rate of Candida spp. by Polident was not significantly different from the removal rate using water. Changes in the surface roughness and color difference among the specimens were slight. There were no significant differences in the bending strengths of the two resins for all concentrations of Gly solution (p>0.05). These results suggested that glycine-type amphoteric surfactant solution may be effective as a denture cleaner in conjunction with an ultrasonic cleaning device.

  18. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

    PubMed

    Lau, Mayank; Amarnath, G S; Muddugangadhar, B C; Swetha, M U; Das, Kopal Anshuraj Ashok Kumar

    2014-04-01

    The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups. The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors. The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the article: Lau M, Amarnath GS, Muddugangadhar BC, Swetha MU, Das KA. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study. J Int Oral Health 2014;6(2):55-61.

  19. Wear rates of artificial denture teeth opposed by natural dentition.

    PubMed

    Douglas, W H; Delong, R; Pintado, M R; Latta, M A

    1993-01-01

    The wear rate of polymeric or composite-based artificial denture teeth on fixed, removable and implant prostheses is important in the maintenance of cuspal form, masticatory efficiency and occlusal stability. A servo-hydraulic based artificial mouth in which an occlusion was established between artificial denture teeth, and the palatal cusp of a human maxillary third molar was established and used to assess the wear resistance of 5 artificial denture tooth materials. Volumetric wear was determined for Dentsply Trublend SLM, Dentsply IPN, Vita Vitapan, Ivoclar Orthotyp and Ivoclar Orthosit denture teeth. Scanning electron microscopy was also done to assess the textural character of the wear facets of each denture tooth sample. The lowest volume loss was observed for Trublend SLM followed by IPN, Orthotyp, Vitapan and Orthosit. Textural assessment of the materials was consistent with the objective wear data.

  20. Evaluation of chitosan quaternary ammonium salt-modified resin denture base material.

    PubMed

    Song, Rong; Zhong, Zhaohua; Lin, Lexun

    2016-04-01

    Chitosan quaternary ammonium salt displays good antioxidant and antibacterial characteristics and it shows appreciable solubility in water. When added to the traditional denture material to form a resin base, it could promote good oral health by improving the oral environment. In this study, chitosan quaternary ammonium salt was added to the denture material following two different methods. After three months of immersion in artificial saliva, the specimens were tested for tensile strength and were scanned by electron microscope. The murine fibroblast cytotoxicity and antibacterial properties were also tested. The result showed no significant differences in the tensile strength and in the proliferation of murine L929 fibroblast cells. The two structures of chitosan quaternary ammonium salt-modified denture material had different degrees of corrosion resistance and antimicrobial properties. These results indicate that chitosan quaternary ammonium salt-modified resin denture base material has the potential to become a new generation oral denture composite material. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis.

    PubMed

    Schwindling, Franz Sebastian; Schwindling, Franz-Peter

    2016-07-01

    The purpose of this study was to assess the survival of mini dental implants (MDI) and to measure prosthetic maintenance needs in a dental practice-based setting. Patients with mandibular removable dentures were provided with MDI to improve denture retention. Complications and maintenance were analyzed by use of patient records and evaluated with Kaplan-Meier curves and the log rank test at a significance level of 0.05. Ninety-nine MDI were placed in 25 patients (mean age: 72 years). Two MDI fractured during placement and eight implants failed during the first weeks. No more implants were lost for up to seven years, resulting in 92% survival. Implant survival differed significantly depending on whether the maxilla was provided with complete dentures (94.9%) or with partial dentures (81%). All prostheses were in use at the time of data extraction. Denture base fractures were observed in six cases, an incidence of fractures of 24%. Some minor intervention was necessary: one resin tooth fractured, retention rings were changed in five cases, and repeated relining was required for 16% of the dentures. After mid-term observation, survival of MDI was good. However, the incidence of denture base fractures and of minor prosthetic complications should not be under-estimated. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases

    PubMed Central

    Alammari, Manal Rahma

    2017-01-01

    Background Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. Objective The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. Methods This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. Results One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p1<0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Conclusion Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability. PMID:29238483

  3. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    PubMed

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 <0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability.

  4. Effect of location of glass fiber-reinforced composite reinforcement on the flexural properties of a maxillary complete denture in vitro.

    PubMed

    Takahashi, Yutaka; Yoshida, Kaneyoshi; Shimizu, Hiroshi

    2011-07-01

    Objective. To evaluate the effect of the location of glass fiber-reinforced composite (FRC) reinforcement on the flexural load at the proportional limit (FL-PL) and the flexural deflection of a maxillary acrylic resin complete denture. Material and methods. Maxillary acrylic resin complete dentures strengthened with and without FRC reinforcement were tested. The polymerized FRC was embedded in the denture base resin in the doughy state and placed (1) under the ridge lap region, (2) in the anterior region, (3) in the middle region or (4) in the anterior and posterior regions. The FL-PL and flexural deflection value at the 100-N loading point of the reinforced maxillary denture specimens were tested. Results. All of the reinforced dentures had a higher FL-PL than the denture without reinforcement but the FL-PL values of all the dentures were not significantly different from each other. The efficiency of the FRC reinforcement compared to the unreinforced denture was 1.54-1.75 times greater. All of the reinforced dentures showed significantly lower deflection compared to the unreinforced denture, but the flexural deflections of all the dentures were not significantly different from each other. Conclusions. The location of the FRC reinforcement did not affect the fracture resistance of the maxillary acrylic resin complete denture. All of the reinforced dentures had higher FL-PL and lower flexural deflection than the denture without reinforcement.

  5. In vitro comparison of the tensile bond strength of denture adhesives on denture bases.

    PubMed

    Kore, Doris R; Kattadiyil, Mathew T; Hall, Dan B; Bahjri, Khaled

    2013-12-01

    With several denture adhesives available, it is important for dentists to make appropriate patient recommendations. The purpose of this study was to evaluate the tensile bond strength of denture adhesives on denture base materials at time intervals of up to 24 hours. Fixodent, Super Poligrip, Effergrip, and SeaBond denture adhesives were tested with 3 denture base materials: 2 heat-polymerized (Lucitone 199 and SR Ivocap) and 1 visible-light-polymerized (shade-stable Eclipse). Artificial saliva with mucin was used as a control. Tensile bond strength was tested in accordance with American Dental Association specifications at 5 minutes, 3 hours, 6 hours, 12 hours, and 24 hours after applying the adhesive. Maximum forces before failure were recorded in megapascals (MPa), and the data were subjected to a 2-way analysis of variance (α=.05). All 4 adhesives had greater tensile bond strength than the control. Fixodent, Super Poligrip, and SeaBond had higher tensile bond strength values than Effergrip. All adhesives had the greatest tensile bond strength at 5 minutes and the least at 24 hours. The 3 denture bases produced significantly different results with each adhesive (P<.001). Lucitone 199 with the adhesives had the greatest tensile bond strength, followed by Ivocap and Eclipse. All 4 adhesives had greater tensile bond strength than the control, and all 4 adhesives were strongest at the 5-minute interval. On all 3 types of denture bases, Effergrip produced significantly lower tensile bond strength, and Fixodent, Super Poligrip, and SeaBond produced significantly higher tensile bond strength. At 24 hours, the adhesive-base combinations with the highest tensile bond strength were Fixodent on Lucitone 199, Fixodent on Eclipse, Fixodent on Ivocap, and Super Poligrip on Ivocap. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  6. Constitutive Behavior and Finite Element Analysis of FRP Composite and Concrete Members.

    PubMed

    Ann, Ki Yong; Cho, Chang-Geun

    2013-09-10

    The present study concerns compressive and flexural constitutive models incorporated into an isoparametric beam finite element scheme for fiber reinforced polymer (FRP) and concrete composites, using their multi-axial constitutive behavior. The constitutive behavior of concrete was treated in triaxial stress states as an orthotropic hypoelasticity-based formulation to determine the confinement effect of concrete from a three-dimensional failure surface in triaxial stress states. The constitutive behavior of the FRP composite was formulated from the two-dimensional classical lamination theory. To predict the flexural behavior of circular cross-section with FRP sheet and concrete composite, a layered discretization of cross-sections was incorporated into nonlinear isoparametric beam finite elements. The predicted constitutive behavior was validated by a comparison to available experimental results in the compressive and flexural beam loading test.

  7. 21 CFR 872.3560 - OTC denture reliner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... applied as a permanent coating or lining on the base or tissue-contacting surface of a denture. The device... Reliners, Repair Kits, and Partially Fabricated Denture Kits.” [52 FR 30097, Aug. 12, 1987, as amended at...

  8. Age-related increase in Wnt inhibitor causes a senescence-like phenotype in human cardiac stem cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, Tamami; Hosoyama, Tohru; Regenerative Medicine Institute, Yamaguchi University Graduate School of Medicine

    Aging of cardiac stem/progenitor cells (CSCs) impairs heart regeneration and leads to unsatisfactory outcomes of cell-based therapies. As the precise mechanisms underlying CSC aging remain unclear, the use of therapeutic strategies for elderly patients with heart failure is severely delayed. In this study, we used human cardiosphere-derived cells (CDCs), a subtype of CSC found in the postnatal heart, to identify secreted factor(s) associated with CSC aging. Human CDCs were isolated from heart failure patients of various ages (2–83 years old). Gene expression of key soluble factors was compared between CDCs derived from young and elderly patients. Among these factors, SFRP1,more » a gene encoding a Wnt antagonist, was significantly up-regulated in CDCs from elderly patients (≥65 years old). sFRP1 levels was increased significantly also in CDCs, whose senescent phenotype was induced by anti-cancer drug treatment. These results suggest the participation of sFRP1 in CSC aging. We show that the administration of recombinant sFRP1 induced cellular senescence in CDCs derived from young patients, as indicated by increased levels of markers such as p16, and a senescence-associated secretory phenotype. In addition, co-administration of recombinant sFRP1 could abrogate the accelerated CDC proliferation induced by Wnt3A. Taken together, our results suggest that canonical Wnt signaling and its antagonist, sFRP1, regulate proliferation of human CSCs. Furthermore, excess sFRP1 in elderly patients causes CSC aging. - Highlights: • Wnt signaling regulates proliferation of human cardiac stem cells. • Expression of sFRP1, which is a Wnt antagonist, is up-regulated in elderly patients with heart failure. • Expression of sFRP1 is increased in anti-cancer drug-induced senescent human cardiac stem cells. • sFRP1 causes cellular senescence of young patients-derived cardiac stem cells.« less

  9. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    PubMed

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from the use of injection molding compared to CAD/CAM and compression molding. © 2017 by the American College of Prosthodontists.

  10. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles : Task 4A : design specifications.

    DOT National Transportation Integrated Search

    2015-08-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 4A, Design Specifications. : Structural design specifications are base...

  11. [A development of FRP frame for crown and bridge resin. (2) Rigidity and adaptability of FRP frame].

    PubMed

    Kimura, H; Teraoka, F

    1990-05-01

    Retainer and pontic of FRP frame for crown and bridge resin were constructed with two different prepregs, used glass cloth and roving as reinforcement. Rigidity and adaptability of the FRP frame and bonding strength of jointing of retainer and pontic were investigated. The glass content was about 50 wt% for both kinds of prepregs. Bonding strength and modulus of FRP plate reinforced with glass roving were about 1.5 times larger than that of the FRP plate reinforced with glass cloth. Bonding strength of FRP specimen constructed by curing the prepreg put on the FRP plate was about 3 kgf/mm2. However, the bonding strength of specimen constructed by curing simultaneously the two prepregs was about 12 kgf/mm2. Though discrepancy of the FRP frame to stone cast of abutment tooth was proportional to the length of pontic, that of the FRP frame with a 50 mm pontic was less than 0.05 mm.

  12. Effects of different surface treatments on the bond strength of acrylic denture teeth to polymethylmethacrylate denture base material.

    PubMed

    Akin, Hakan; Kirmali, Omer; Tugut, Faik; Coskun, Mehmet Emre

    2014-09-01

    The purpose of this study was to investigate the effects of various surface pretreatments in the ridge lap area of acrylic resin denture teeth on the shear bond strength to heat-polymerized polymethylmethacrylate (PMMA) denture base resin. Tooth debonding of the denture is a major problem for patients with removable prostheses. A total of 84 central incisor denture teeth were used in this study. Seven test groups with 12 specimens for each group were prepared as follows: untreated (control, group C), ground, with a tungsten carbide bur (group H), airborne-particle abrasion (group AA), primed with methyl methacrylate (group M), treated with izobutyl methacrylate (group iBMA), Eclipse Bonding Agent applied (group E), and Er:YAG laser irradiated (group L). Test specimens were produced according to the manufacturers' instructions and mounted to a universal testing machine for shear testing with a crosshead speed of 1 mm/min. Data were evaluated by one way variance analysis (ANOVA) and Tukey's test (α=0.05). Similar bond strength values were found between groups L and M, and these were the highest shear bond strengths among the groups. The lowest one was observed in group E. All surface treatments, except group E, exhibited significant difference when compared with group C (p<0.05). Lasing of the ridge lap area to enhance the bond strength of acrylic resin denture teeth to PMMA denture base resin might be an alternative to wetting with MMA monomer. To overcome tooth debonding, surface treatment of the ridge lap area should be performed as part of denture fabrication.

  13. Overdenture retained by teeth using a definitive denture base technique: a case report.

    PubMed

    Nascimento, D F F; dos Santos, J F F; Marchini, L

    2010-09-01

    This paper presents a technique involving the use of a definitive denture base to make overdentures. Cores with ball attachments were cemented over remaining lower teeth. Impressions of the edentulous maxilla and mandible were taken to obtain a definitive acrylic resin base. The definitive base of the mandible was perforated at the location of ball attachments and its female components were fixed to the base using acrylic resin directly in the patient's mouth. Wax rims were then made, jaw relationships recorded, teeth mounted and tried in, and the dentures were cured. This technique allowed for easy fixing of female components and better retention during the recording of jaw relationships, and can also be used in the construction of implant retained dentures.

  14. [The effect of denture base resins coated with antibacterial coating on water sorption, solubility and monomer elution].

    PubMed

    Yang, Yang; Gong, Hai-Huan; Song, Ai-Yang; Feng, Dan; Jin, Jie; Zhu, Song

    2015-02-01

    To determine the influence of denture base resins coated with antibacterial coating on water sorption, solubility and monomer elution. The values of water sorption and solubility were measured according to YY 0270-2003 and gas chromatography was used to examine the leachability of 4 commercially available heat-cured acrylic resins between experimental group and control group. Degree of crosslinking of the experimental heat-cured acrylic denture bases we remeasured by soxhlet extraction method. The data was analyzed by 17.0 software package. The values of water sorption, solubility and monomer elution of experimental group were lower compared to the control group. Degree of crosslinking of Heraeus reins was the highest among the experimental heat-cured acrylic denture bases. There is a same trend among water sorption, degree of crosslinking and the monomer elution. When the degree of crosslinking increases, the values of water sorption and monomer elution decrease. Antibacterial coating can improve the comprehensive properties of the denture base resins.

  15. Mechanical properties of injection-molded thermoplastic denture base resins.

    PubMed

    Hamanaka, Ippei; Takahashi, Yutaka; Shimizu, Hiroshi

    2011-03-01

    To investigate the mechanical properties of injection-molded thermoplastic denture base resins. Four injection-molded thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were used in this study. The flexural strength at the proportional limit (FS-PL), the elastic modulus, and the Charpy impact strength of the denture base resins were measured according to International Organization for Standardization (ISO) 1567 and ISO 1567:1999/Amd 1:2003. The descending order of the FS-PL was: conventional PMMA > polyethylene terephthalate, polycarbonate > two polyamides. The descending order of the elastic moduli was: conventional PMMA > polycarbonate > polyethylene terephthalate > two polyamides. The descending order of the Charpy impact strength was: polyamide (Nylon PACM12) > polycarbonate > polyamide (Nylon 12), polyethylene terephthalate > conventional PMMA. All of the injection-molded thermoplastic resins had significantly lower FS-PL, lower elastic moduli, and higher or similar impact strength compared to the conventional PMMA. The polyamide denture base resins had low FS-PL and low elastic moduli; one of them possessed very high impact strength, and the other had low impact strength. The polyethylene terephthalate denture base resin showed a moderately high FS-PL, moderate elastic modulus, and low impact strength. The polycarbonate denture base resin had a moderately high FS-PL, moderately high elastic modulus, and moderate impact strength.

  16. Dental health professional recommendation and consumer habits in denture cleansing.

    PubMed

    Axe, Alyson S; Varghese, Roshan; Bosma, MaryLynn; Kitson, Nicola; Bradshaw, David J

    2016-02-01

    Regular cleaning of dentures is essential to the oral and general health of denture wearers. Only limited systematic data are available on the recommendations that dental health care professionals (DHCPs) make to patients for denture cleaning. Data on denture wearers' cleaning regimens are also lacking. The purpose of this study was to provide data on recommendations that DHCPs make to patients for denture cleaning and on the cleaning regimens of denture wearers. DHCPs (n=613), including dentists and hygienists, were surveyed in developed (Japan, USA, Italy) and developing (Brazil, India) countries. A questionnaire assessing a range of denture cleaning recommendations was used. The questions addressed products, frequency, how to use remedies, the suggested dilution and duration of cleansing treatment, the location of dentures while cleaning, and the reasoning behind the recommendation of particular products or modes of treatment. Denture cleansing methods and the routine of denture wearers in developed and developing countries were also surveyed with a questionnaire (n=2862) and a 1-week diary (n=1462). An average of more than 2 treatments was recommended by DHCPs. Specialist denture cleanser tablets, "regular" toothpaste, mouthwash, soap and water, denture paste, foam or liquid denture cleanser, and dishwashing detergents were most commonly recommended; other product recommendations included baking soda, vinegar, salt water, and bleach. More than 10% of DHCPs made no primary recommendation on cleaning. Denture tablets were more commonly recommended in developed countries, whereas toothpaste was the most common recommendation in developing countries. Denture wearers used products and methods similar to those recommended by DHCPs. Toothpaste, water, and mouthwash were used more frequently than denture tablets. More than 75% of denture wearers reported using denture cleanser tablets for more than 5 minutes, whereas soap and toothpaste were typically used for less than 2 minutes. DHCP recommendations and denture wearer habits are diverse, with no consensus on the most appropriate denture cleaning methods. This reflects a lack of clear, systematic evidence upon which to base recommendations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Variations in Flexural Strength of Heat-polymerized Acrylic Resin after the Usage of Denture Cleansers.

    PubMed

    Ragher, Mallikarjuna; Vinayakumar, G; Patil, Sanketsopan; Chatterjee, Aishwarya; Mallikarjuna, D M; Dandekeri, Savita; Swetha, V; Pradeep, M R

    2016-04-01

    The objective of this study was to evaluate and compare changes in the flexural strength of heat-cured denture base resins when treated using denture cleansers. A total of 40 specimens with dimension 65 mm length, 10 mm width, and 3 mm thickness were prepared as per ISO 1567 specification. A total of 10 specimens were immersed in distilled water to be used as control. Of the remaining 30 samples, 10 were treated with Clinsodent, 10 with VI-Clean, and 10 with Clanden denture cleansers. Specimens in each group were subjected to three-point flexural load in universal testing machine at a cross-head speed of 5 mm/min. The peak load (N) was recorded and flexural strength was calculated. The findings were analyzed using Kruskal-Wallis analysis of variance and Mann-Whitney test. Heat-cured denture base resin selected for this study showed significant difference in flexural strength after immersion in denture cleansers Clinsodent, VI-Clean, and Clanden solutions, when compared with the control group. Findings of this study showed that denture cleansers altered the flexural strength of heat polymerized acrylic resins that endured soaking cycles which simulated 180 days of use. Hence, denture cleansers should be used with caution, once a day after brushing the dentures. It is advisable for patients to follow the manufacturer's instructions.

  18. Behaviour of concrete beams reinforced withFRP prestressed concrete prisms

    NASA Astrophysics Data System (ADS)

    Svecova, Dagmar

    The use of fibre reinforced plastics (FRP) to reinforce concrete is gaining acceptance. However, due to the relatively low modulus of FRP, in comparison to steel, such structures may, if sufficient amount of reinforcement is not used, suffer from large deformations and wide cracks. FRP is generally more suited for prestressing. Since it is not feasible to prestress all concrete structures to eliminate the large deflections of FRP reinforced concrete flexural members, researchers are focusing on other strategies. A simple method for avoiding excessive deflections is to provide sufficiently high amount of FRP reinforcement to limit its stress (strain) to acceptable levels under service loads. This approach will not be able to take advantage of the high strength of FRP and will be generally uneconomical. The current investigation focuses on the feasibility of an alternative strategy. This thesis deals with the flexural and shear behaviour of concrete beams reinforced with FRP prestressed concrete prisms. FRP prestressed concrete prisms (PCP) are new reinforcing bars, made by pretensioning FRP and embedding it in high strength grout/concrete. The purpose of the research is to investigate the feasibility of using such pretensioned rebars, and their effect on the flexural and shear behaviour of reinforced concrete beams over the entire loading range. Due to the prestress in the prisms, deflection of concrete beams reinforced with this product is substantially reduced, and is comparable to similarly steel reinforced beams. The thesis comprises both theoretical and experimental investigations. In the experimental part, nine beams reinforced with FRP prestressed concrete prisms, and two companion beams, one steel and one FRP reinforced were tested. All the beams were designed to carry the same ultimate moment. Excellent flexural and shear behaviour of beams reinforced with higher prestressed prisms is reported. When comparing deflections of three beams designed to have the same ultimate capacity, but reinforced with either steel, PCP or FRP rebars, the service load deflections of beams reinforced with PCP are comparable to that of a steel reinforced concrete beam, and are four times smaller than the deflection of the companion FRP reinforced beam. Similarly, the crack width of the PCP reinforced beams under service loads is comparable to that of the steel reinforced beam while the FRP reinforced beam developed unacceptably wide cracks. In the analytical part comprehensive analysis of the experimental data in both flexure and shear is performed. It is determined that the existing design expressions for ultimate flexural strength and service load deflection calculation cannot accurately predict the response of PCP reinforced beams. Accordingly, new expressions for calculation of deflection, crack width, tension stiffening, and ultimate capacity of the PCP reinforced beams are proposed. The predictions of the proposed methods of analysis agree very well with the corresponding experimental data. Based on the results of the current study, it is concluded that high strength concrete prisms prestressed with carbon fibre reinforced plastic bars can be used as reinforcement in concrete structures to avoid the problems of large deflections and wide cracks under service loads.

  19. Smart fiber-reinforced polymer anchorage system with optical fiber Bragg grating sensors

    NASA Astrophysics Data System (ADS)

    Huang, Minghua; Zhou, Zhi; He, Jianping; Chen, Genda; Ou, Jinping

    2010-03-01

    Civil Engineers have used fiber reinforced polymer (FRP) with high axial strength as an effective and economical alternative to steel in harsh corrosion environments. However, the practical applications of FRP are limited by the tendency of FRP materials to fail suddenly under lateral pressure and surface injury. For example, shear stresses result from the bonding effect between the FRP material and the structure of the anchorage system due to the lower shear strength of FRP. This paper proposes a novel smart FRP anchorage system with embedded optical fiber Bragg grating (FBG) sensors to monitor the axial strain state and accordingly the interfacial shear stress, as well as the interfacial damage characteristics of FRP anchorage. One FBG sensor was embedded in an FRP rod outside the anchorage region to evaluate the properties of the material, and seven FBG sensors were distributed along the rod in the anchor to monitor the axial strain variations and study the interfacial mechanical behaviors of the smart FRP anchorage under a static pulling load. The experimental results agreed well with theoretical predictions. The smart FRP anchorage system with optical FBG sensors proves effective and practical for monitoring the long-term mechanical behavior of FRP anchorage systems.

  20. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2016-08-01

    Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported. The purpose of this in vitro study was to compare the denture base adaptation of pack and press, pour, injection, and CAD-CAM techniques for fabricating dentures to determine which process produces the most accurate and reproducible adaptation. A definitive cast was duplicated to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. A master denture was made using the CAD-CAM process and was then used to create a putty mold for the fabrication of 30 standardized wax festooned dentures, 10 for each of the conventional processing techniques (pack and press, pour, injection). Scan files from 10 casts were sent to Global Dental Science, LLC for fabrication of the CAD-CAM test specimens. After specimens for each of the 4 techniques had been fabricated, they were hydrated for 24 hours and the intaglio surface laser scanned. The scan file of each denture was superimposed on the scan file of the corresponding preprocessing cast using surface matching software. Measurements were made at 60 locations, providing evaluation of fit discrepancies at the following areas: apex of the denture border, 6 mm from the denture border, crest of the ridge, palate, and posterior palatal seal. The use of median and interquartile range was used to assess accuracy and reproducibility. The Levine and Kruskal-Wallis analysis of variance was used to evaluate differences between processing techniques at the 5 specified locations (α=.05). The ranking of results based on median and interquartile range determined that the accuracy and reproducibility of the CAD-CAM technique was more consistently localized around zero at 3 of the 5 locations. Therefore, the CAD-CAM technique showed the best combination of accuracy and reproducibility among the tested fabrication techniques. The pack and press technique was more accurate at 2 of the 5 locations; however, its interquartile range (reproducibility) was the greatest of the 4 tested processing techniques. The pour technique was the most reproducible at 2 of the 5 locations; however, its accuracy was the lowest of the tested techniques. The CAD-CAM fabrication process was the most accurate and reproducible denture fabrication technique when compared with pack and press, pour, and injection denture base processing techniques. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Constitutive Behavior and Finite Element Analysis of FRP Composite and Concrete Members

    PubMed Central

    Ann, Ki Yong; Cho, Chang-Geun

    2013-01-01

    The present study concerns compressive and flexural constitutive models incorporated into an isoparametric beam finite element scheme for fiber reinforced polymer (FRP) and concrete composites, using their multi-axial constitutive behavior. The constitutive behavior of concrete was treated in triaxial stress states as an orthotropic hypoelasticity-based formulation to determine the confinement effect of concrete from a three-dimensional failure surface in triaxial stress states. The constitutive behavior of the FRP composite was formulated from the two-dimensional classical lamination theory. To predict the flexural behavior of circular cross-section with FRP sheet and concrete composite, a layered discretization of cross-sections was incorporated into nonlinear isoparametric beam finite elements. The predicted constitutive behavior was validated by a comparison to available experimental results in the compressive and flexural beam loading test. PMID:28788312

  2. LSA SAF Meteosat FRP products - Part 2: Evaluation and demonstration for use in the Copernicus Atmosphere Monitoring Service (CAMS)

    NASA Astrophysics Data System (ADS)

    Roberts, G.; Wooster, M. J.; Xu, W.; Freeborn, P. H.; Morcrette, J.-J.; Jones, L.; Benedetti, A.; Jiangping, H.; Fisher, D.; Kaiser, J. W.

    2015-11-01

    Characterising the dynamics of landscape-scale wildfires at very high temporal resolutions is best achieved using observations from Earth Observation (EO) sensors mounted onboard geostationary satellites. As a result, a number of operational active fire products have been developed from the data of such sensors. An example of which are the Fire Radiative Power (FRP) products, the FRP-PIXEL and FRP-GRID products, generated by the Land Surface Analysis Satellite Applications Facility (LSA SAF) from imagery collected by the Spinning Enhanced Visible and Infrared Imager (SEVIRI) onboard the Meteosat Second Generation (MSG) series of geostationary EO satellites. The processing chain developed to deliver these FRP products detects SEVIRI pixels containing actively burning fires and characterises their FRP output across four geographic regions covering Europe, part of South America and Northern and Southern Africa. The FRP-PIXEL product contains the highest spatial and temporal resolution FRP data set, whilst the FRP-GRID product contains a spatio-temporal summary that includes bias adjustments for cloud cover and the non-detection of low FRP fire pixels. Here we evaluate these two products against active fire data collected by the Moderate Resolution Imaging Spectroradiometer (MODIS) and compare the results to those for three alternative active fire products derived from SEVIRI imagery. The FRP-PIXEL product is shown to detect a substantially greater number of active fire pixels than do alternative SEVIRI-based products, and comparison to MODIS on a per-fire basis indicates a strong agreement and low bias in terms of FRP values. However, low FRP fire pixels remain undetected by SEVIRI, with errors of active fire pixel detection commission and omission compared to MODIS ranging between 9-13 % and 65-77 % respectively in Africa. Higher errors of omission result in greater underestimation of regional FRP totals relative to those derived from simultaneously collected MODIS data, ranging from 35 % over the Northern Africa region to 89 % over the European region. High errors of active fire omission and FRP underestimation are found over Europe and South America and result from SEVIRI's larger pixel area over these regions. An advantage of using FRP for characterising wildfire emissions is the ability to do so very frequently and in near-real time (NRT). To illustrate the potential of this approach, wildfire fuel consumption rates derived from the SEVIRI FRP-PIXEL product are used to characterise smoke emissions of the 2007 "mega-fire" event focused on Peloponnese (Greece) and used within the European Centre for Medium-Range Weather Forecasting (ECMWF) Integrated Forecasting System (IFS) as a demonstration of what can be achieved when using geostationary active fire data within the Copernicus Atmosphere Monitoring Service (CAMS). Qualitative comparison of the modelled smoke plumes with MODIS optical imagery illustrates that the model captures the temporal and spatial dynamics of the plume very well, and that high temporal resolution emissions estimates such as those available from a geostationary orbit are important for capturing the sub-daily variability in smoke plume parameters such as aerosol optical depth (AOD), which are increasingly less well resolved using daily or coarser temporal resolution emissions data sets. Quantitative comparison of modelled AOD with coincident MODIS and AERONET (Aerosol Robotic Network) AOD indicates that the former is overestimated by ~ 20-30 %, but captures the observed AOD dynamics with a high degree of fidelity. The case study highlights the potential of using geostationary FRP data to drive fire emissions estimates for use within atmospheric transport models such as those implemented in the Monitoring Atmospheric Composition and Climate (MACC) series of projects for the CAMS.

  3. Behaviour of fibre reinforced polymer confined reinforced concrete columns under fire condition

    NASA Astrophysics Data System (ADS)

    Chowdhury, Ershad Ullah

    In recent years, fibre reinforced polymer (FRP) materials have demonstrated enormous potential as materials for repairing and retrofitting concrete bridges that have deteriorated from factors such as electro-chemical corrosion and increased load requirements. However, concerns associated with fire remain an obstacle to applications of FRP materials in buildings and parking garages due to FRP's sensitivity to high temperatures as compared with other structural materials and to limited knowledge on their thermal and mechanical behaviour in fire. This thesis presents results from an ongoing study on the fire performance of FRP materials, fire insulation materials and systems, and FRP wrapped reinforced concrete columns. The overall goal of the study is to understand the fire behaviour of FRP materials and FRP strengthened concrete columns and ultimately, provide rational fire safety design recommendations and guidelines for FRP strengthened concrete columns. A combined experimental and numerical investigation was conducted to achieve the goals of this research study. The experimental work consisted of both small-scale FRP material testing at elevated temperatures and full-scale fire tests on FRP strengthened columns. A numerical model was developed to simulate the behaviour of unwrapped reinforced concrete and FRP strengthened reinforced concrete square or rectangular columns in fire. After validating the numerical model against test data available in literature, it was determined that the numerical model can be used to analyze the behaviour of concrete axial compressive members in fire. Results from this study also demonstrated that although FRP materials experience considerable loss of their mechanical and bond properties at temperatures somewhat below the glass transition temperature of the resin matrix, externally-bonded FRP can be used in strengthening concrete structural members in buildings, if appropriate supplemental fire protection system is provided over the FRP strengthening system.

  4. Estimation of Biomass Burning Emissions by Fusing Fire Radiative Power Observed from Polar-orbiting and Geostationary Satellites across the Continental United States

    NASA Astrophysics Data System (ADS)

    Li, F.; Zhang, X.; Kondragunta, S.

    2016-12-01

    Trace gases and aerosols released from biomass burning significantly disturb the energy balance of the Earth and also degrade regional air quality. However, biomass burning emissions (BBE) have been poorly estimated using the traditional bottom-up approach because of the substantial uncertainties in the burned area and fuel loads. Recently, Fire Radiative Power (FRP) derived from satellite fire observations enables the estimation of BBE at multiple spatial scales in near real time. Nonetheless, it is very challenging to accurately produce reliable FRP diurnal cycles from either polar-orbiting satellites or geostationary satellites for the calculation of the temporally integrated FRP, Fire Radiative Energy (FRE). Here we reconstruct FRP diurnal cycles by fusing FRP observed from polar-orbiting and geostationary satellites and estimate BBE from 2011 to 2015 across the Continental United States. Specifically, FRP from the Geostationary Operational Environmental Satellite (GOES) is preprocessed and calibrated using the collocated and concurred observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) over Landsat TM burn scars. The climatologically diurnal FRP curves are then calculated from the calibrated GOES FRP for the 25 Bailey's ecoregions. By fitting MODIS FRP and the calibrated GOES FRP to the climatological curves, FRP diurnal cycles are further reconstructed for individual days at a 0.25-degree grid. Both FRE estimated from FRP diurnal cycles and ecoregion specified FRE combustion rates are used to estimate hourly BBE. The estimated BBE is finally evaluated using QFED and GFED4.0 inventories and emissions modeled using Landsat TM 30m burn severities and 30m fuel loading from Fuel Characteristic Classification System. The results show that BBE estimates are greatly improved by using the reconstructed FRP diurnal cycles from high temporal (GOES) and high spatial resolution (MODIS) FRP observations.

  5. Reliability model for ductile hybrid FRP rebar using randomly dispersed chopped fibers

    NASA Astrophysics Data System (ADS)

    Behnam, Bashar Ramzi

    Fiber reinforced polymer composites or simply FRP composites have become more attractive to civil engineers in the last two decades due to their unique mechanical properties. However, there are many obstacles such as low elasticity modulus, non-ductile behavior, high cost of the fibers, high manufacturing costs, and absence of rigorous characterization of the uncertainties of the mechanical properties that restrict the use of these composites. However, when FRP composites are used to develop reinforcing rebars in concrete structural members to replace the conventional steel, a huge benefit can be achieved since FRP materials don't corrode. Two FRP rebar models are proposed that make use of multiple types of fibers to achieve ductility, and chopped fibers are used to reduce the manufacturing costs. In order to reach the most optimum fractional volume of each type of fiber, to minimize the cost of the proposed rebars, and to achieve a safe design by considering uncertainties in the materials and geometry of sections, appropriate material resistance factors have been developed, and a Reliability Based Design Optimization (RBDO), has been conducted for the proposed schemes.

  6. Self-sensing concrete-filled FRP tubes using FBG strain sensors

    NASA Astrophysics Data System (ADS)

    Yan, Xin; Li, Hui

    2007-07-01

    Concrete-filled fiber-reinforced polymer (FRP) tube is a type of newly developed structural column. It behaves brittle failure at its peak strength, and so the health monitoring on the hoop strain of the FRP tube is essential for the life cycle safety of the structure. Herein, three types of FRP tubes including 5-ply tube, 2-ply tube with local reinforcement and FRP-steel composite tube were embedded with the optic fiber Bragg grating (FBG) strain sensors in the inter-ply of FRP or the interface between FRP and steel in the middle height and the hoop direction. The compressive behaviors of the concrete-filled FRP tubes were experimentally studied. The hoop strains of the FRP tubes were recorded in real time using the embedded FBG strain sensors as well as the embedded or surface electric resistance strain gauges. Results indicated that the FBG strain sensors can faithfully record the hoop strains of the FRP tubes in compression as compared with the embedded or surface electric resistance strain gauges, and the strains recorded can reach more than μɛ.

  7. Application of sintered titanium alloys to metal denture bases: a study of titanium powder sheets for complete denture base.

    PubMed

    Doi, H; Harrori, M; Hasegawa, K; Yoshinari, M; Kawada, E; Oda, Y

    2001-02-01

    The purpose of this study was the fabrication of titanium powder sheets to enable the application of sintered titanium alloys as metal denture bases. The effects of titanium particle shape and size, binder content, and plasticizer content on the surface smoothness, tensile strength and elongation of titanium powder sheets was investigated. To select a suitable ratio of powdered metal contents for application as a metal denture base, the effects of aluminum content in Ti sheets and various other powder metal contents in Ti-Al sheets on the density, sintering shrinkage, and bending strength were evaluated. Based on the results of the above experiments, we developed a mixed powder sheet composed of 83Ti-7Al-10Cr with TA45 titanium powder (atomized, -45 microm), and 8 mass% binder content. This titanium alloy sheet had good formability and ductility. Its sintered titanium alloy had a density of 3.2 g/cm3, sintering shrinkage of 3.8%, and bending strength of 403 MPa. The titanium alloy sheet is clinically acceptable for fabricating denture bases.

  8. Impact of Packing and Processing Technique on Mechanical Properties of Acrylic Denture Base Materials

    PubMed Central

    Nejatian, Touraj; Sefat, Farshid; Johnson, Tony

    2015-01-01

    The fracture resistance of polymethylmethacrylate (PMMA) as the most popular denture base material is not satisfactory. Different factors can be involved in denture fracture. Among them, flexural fatigue and impact are the most common failure mechanisms of an acrylic denture base. It has been shown that there is a correlation between the static strength and fatigue life of composite resins. Therefore, the transverse strength of the denture base materials can be an important indicator of their service life. In order to improve the fracture resistance of PMMA, extensive studies have been carried out; however, only a few promising results were achieved, which are limited to some mechanical properties of PMMA at the cost of other properties. This study aimed at optimizing the packing and processing condition of heat-cured PMMA as a denture base resin in order to improve its biaxial flexural strength (BFS). The results showed that the plain type of resin with a powder/monomer ratio of 2.5:1 or less, packed conventionally and cured in a water bath for 2 h at 95 °C provides the highest BFS. Also, it was found that the performance of the dry heat processor is inconsistent with the number of flasks being loaded.

  9. In vitro evaluation of the flexural properties of All-on-Four provisional fixed denture base resin partially reinforced with fibers.

    PubMed

    Li, Bei Bei; Xu, Jia Bin; Cui, Hong Yan; Lin, Ye; Di, Ping

    2016-01-01

    The aim of this study was to assess the effects of partial carbon or glass fiber reinforcement on the flexural properties of All-on-Four provisional fixed denture base resin. The carbon or glass fibers were woven (3% by weight) together in three strands and twisted and tightened between the two abutments in a figure-of-"8" pattern. Four types of specimens were fabricated for the three-point loading test. The interface between the denture base resin and fibers was examined using scanning electron microscopy (SEM). Reinforcement with carbon or glass fibers between two abutments significantly increased the flexural strength and flexural modulus. SEM revealed relatively continuous contact between the fibers and acrylic resin. The addition of carbon or glass fibers between two abutments placed on All-on-Four provisional fixed denture base resin may be clinically effective in preventing All-on-Four denture fracture and can provide several advantages for clinical use.

  10. A clinical evaluation denture adhesives used by patients with xerostomia.

    PubMed

    Bogucki, Zdzislaw A; Napadlek, Piotr; Dabrowa, Tomasz

    2015-02-01

    The purpose of study was to analyze the participants' opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia.

  11. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing.

    PubMed

    Zhang, Yong-de; Jiang, Jin-gang; Liang, Ting; Hu, Wei-ping

    2011-12-01

    Artificial teeth are very complicated in shape, and not easy to be grasped and manipulated accurately by a single robot. The method of tooth-arrangement by multi-manipulator for complete denture manufacturing proposed in this paper. A novel complete denture manufacturing mechanism is designed based on multi-manipulator and dental arch generator. Kinematics model of the multi-manipulator tooth-arrangement robot is built by analytical method based on tooth-arrangement principle for full denture. Preliminary experiments on tooth-arrangement are performed using the multi-manipulator tooth-arrangement robot prototype system. The multi-manipulator tooth-arrangement robot prototype system can automatically design and manufacture a set of complete denture that is suitable for a patient according to the jaw arch parameters. The experimental results verified the validity of kinematics model of the multi-manipulator tooth-arrangement robot and the feasibility of the manufacture strategy of complete denture fulfilled by multi-manipulator tooth-arrangement robot.

  12. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data.

    PubMed

    Goodacre, Charles J; Garbacea, Antoanela; Naylor, W Patrick; Daher, Tony; Marchack, Christopher B; Lowry, Jean

    2012-01-01

    The clinical impression procedures described in this article provide a method of recording the morphology of the intaglio and cameo surfaces of complete denture bases and also identify muscular and phonetic locations for the prosthetic teeth. When the CAD/CAM technology for fabricating complete dentures becomes commercially available, it will be possible to scan the denture base morphology and tooth positions recorded with this technique and import those data into a virtual tooth arrangement program where teeth can be articulated and then export the data to a milling device for the fabrication of the complete dentures. A prototype 3-D tooth arrangement program is described in this article that serves as an example of the type of program than can be used to arrange prosthetic teeth virtually as part of the overall CAD/CAM fabrication of complete dentures. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. Biomass Combustions and Burning Emissions Inferred from GOES Fire Radiative Power

    NASA Astrophysics Data System (ADS)

    Zhang, X.; Kondragunta, S.; Schmidt, C.

    2007-12-01

    Biomass burning significantly affects air quality and climate changes. Current estimates of burning emissions are rather imprecise and vary markedly with different methodologies. This paper investigates biomass burning consumption and emissions using GOES (Geostationary Operational Environmental Satellites) WF_ABBA (Wildfire Automated Biomass Burning Algorithm) fire product. In doing this, we establish a set of representatives in diurnal patterns of half-hourly GOES Fire Radiative Power (FRP) for various ecosystems. The representative patterns are used to fill the missed and poor observations of half hourly FRP in GOES fire data for individual fire pixels. The simulated FRP is directly applied to the calculation of the biomass combusted during fire activities. The FRP-based biomass combustion is evaluated using the estimates using a traditional model which integrates burned area, fuel loading, and combustion factor. In the traditional model calculation, we derive burned areas from GOES WF_ABBA fire size. Fuel loading includes three different types (1) MODIS Vegetation Property-based Fuel System (MVPFS), (2) National Dangerous Rating Systems (NFDRS), and (3) the Fuel Characteristic Classification System (FCCS). By comparing the biomass combustions across the Contiguous United States (CONUS) from 2003-2005, we conclude that FRP is an effective tool to estimate the biomass burning emissions. Finally, we examine the temporal and spatial patterns in biomass combustions and emissions (PM2.5, CO, NH3) across the CONUS.

  14. Damping mathematical modelling and dynamic responses for FRP laminated composite plates with polymer matrix

    NASA Astrophysics Data System (ADS)

    Liu, Qimao

    2018-02-01

    This paper proposes an assumption that the fibre is elastic material and polymer matrix is viscoelastic material so that the energy dissipation depends only on the polymer matrix in dynamic response process. The damping force vectors in frequency and time domains, of FRP (Fibre-Reinforced Polymer matrix) laminated composite plates, are derived based on this assumption. The governing equations of FRP laminated composite plates are formulated in both frequency and time domains. The direct inversion method and direct time integration method for nonviscously damped systems are employed to solve the governing equations and achieve the dynamic responses in frequency and time domains, respectively. The computational procedure is given in detail. Finally, dynamic responses (frequency responses with nonzero and zero initial conditions, free vibration, forced vibrations with nonzero and zero initial conditions) of a FRP laminated composite plate are computed using the proposed methodology. The proposed methodology in this paper is easy to be inserted into the commercial finite element analysis software. The proposed assumption, based on the theory of material mechanics, needs to be further proved by experiment technique in the future.

  15. Parametric Study of Shear Strength of Concrete Beams Reinforced with FRP Bars

    NASA Astrophysics Data System (ADS)

    Thomas, Job; Ramadass, S.

    2016-09-01

    Fibre Reinforced Polymer (FRP) bars are being widely used as internal reinforcement in structural elements in the last decade. The corrosion resistance of FRP bars qualifies its use in severe and marine exposure conditions in structures. A total of eight concrete beams longitudinally reinforced with FRP bars were cast and tested over shear span to depth ratio of 0.5 and 1.75. The shear strength test data of 188 beams published in various literatures were also used. The model originally proposed by Indian Standard Code of practice for the prediction of shear strength of concrete beams reinforced with steel bars IS:456 (Plain and reinforced concrete, code of practice, fourth revision. Bureau of Indian Standards, New Delhi, 2000) is considered and a modification to account for the influence of the FRP bars is proposed based on regression analysis. Out of the 196 test data, 110 test data is used for the regression analysis and 86 test data is used for the validation of the model. In addition, the shear strength of 86 test data accounted for the validation is assessed using eleven models proposed by various researchers. The proposed model accounts for compressive strength of concrete ( f ck ), modulus of elasticity of FRP rebar ( E f ), longitudinal reinforcement ratio ( ρ f ), shear span to depth ratio ( a/ d) and size effect of beams. The predicted shear strength of beams using the proposed model and 11 models proposed by other researchers is compared with the corresponding experimental results. The mean of predicted shear strength to the experimental shear strength for the 86 beams accounted for the validation of the proposed model is found to be 0.93. The result of the statistical analysis indicates that the prediction based on the proposed model corroborates with the corresponding experimental data.

  16. Study on Antibacterial Property of PMMA Denture Base Materials with Negative Ion Powder

    NASA Astrophysics Data System (ADS)

    Liu, Meitian; Zhang, Xiaohui; Zhang, Jingting; Zheng, Qian; Liu, Bin

    2018-01-01

    To prepare the denture base resin with negative ion powder and evaluate the antibacterial effect of denture base resin with different contents of negative ion powder for clinical application. Method: Denture base material with negative ion powder was prepared by in-situ polymerization method, 50mm * 50mm * 2mm standard samples were prepared respectively. Antibacterial properties were tested with the film contact method. Experimental bacteria: Staphylococcus aureus (ATCC6538), Escherichia coli (ATCC8099).Result:With the increase of the amount of negative ion powder, the inhibition rate of the composite material to Escherichia coli and Staphylococcus aureus showed an increasing trend, and the number of residual bacteria on the surface showed a decreasing trend. When the content of negative ion powder was 2%, the composite material Staphylococcus aureus and Escherichia coli were 77.9% and 80.3% respectively. When the addition ratio was 5%, the bactericidal rate of the composite material to Staphylococcus aureus and Escherichia coli reached 98.2% and 99.1% respectively. Conclusion: The denture base material containing more than 2%wt negative ion powder has strong sterilization.

  17. Effect of thermal shock on mechanical properties of injection-molded thermoplastic denture base resins.

    PubMed

    Takahashi, Yutaka; Hamanaka, Ippei; Shimizu, Hiroshi

    2012-07-01

    This study investigated the effect of thermal shock on the mechanical properties of injection-molded thermoplastic denture base resins. Four thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were tested. Specimens of each denture base material were fabricated according to ISO 1567 and were either thermocycled or not thermocycled (n = 10). The flexural strength at the proportional limit (FS-PL), the elastic modulus and the Charpy impact strength of the denture base materials were estimated. Thermocycling significantly decreased the FS-PL of one of the polyamides and the PMMA and it significantly increased the FS-PL of one of the polyamides. In addition, thermocycling significantly decreased the elastic modulus of one of the polyamides and significantly increased the elastic moduli of one of the polyamides, the polyethylene terephthalate, polycarbonate and PMMA. Thermocycling significantly decreased the impact strength of one of the polyamides and the polycarbonate. The mechanical properties of injection-molded thermoplastic denture base resins changed after themocycling.

  18. Self-monitoring fiber reinforced polymer strengthening system for civil engineering infrastructures

    NASA Astrophysics Data System (ADS)

    Jiang, Guoliang; Dawood, Mina; Peters, Kara; Rizkalla, Sami

    2008-03-01

    Fiber reinforced polymer (FRP) materials are currently used for strengthening civil engineering infrastructures. The strengthening system is dependant on the bond characteristics of the FRP to the external surface of the structure to be effective in resisting the applied loads. This paper presents an innovative self-monitoring FRP strengthening system. The system consists of two components which can be embedded in FRP materials to monitor the global and local behavior of the strengthened structure respectively. The first component of the system is designed to evaluate the applied load acting on a structure based on elongation of the FRP layer along the entire span of the structure. Success of the global system has been demonstrated using a full-scale prestressed concrete bridge girder which was loaded up to failure. The test results indicate that this type of sensor can be used to accurately determine the load prior to failure within 15 percent of the measured value. The second sensor component consists of fiber Bragg grating sensors. The sensors were used to monitor the behavior of steel double-lap shear splices tested under tensile loading up to failure. The measurements were used to identify abnormal structural behavior such as epoxy cracking and FRP debonding. Test results were also compared to numerical values obtained from a three dimensional shear-lag model which was developed to predict the sensor response.

  19. Guidelines for the use of fiberglass reinforced plastic in utility FGD systems. [Flue gas desulfurization (FGD); contains glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rapoza, R.J.; Vollmer, H.R.; Haberly, K.L.

    1992-11-01

    Fiberglass reinforced plastic (FRP) materials offer excellent corrosion-resistant properties and long-term cost advantages compared to exotic alloys or organic lining systems. This guideline document provides potential buyers of FRP FGD (flue gas desulfurization) equipment with enough knowledge of FRP materials and methods to make informed decisions when procuring FRP equipment or services. It is divided into the following chapters: application criteria, procurement strategies, FRP basics, guidelines for designing FRP equipment, quality management. A glossary and manufacturers information/recommendations are included.

  20. PMMA denture base material enhancement: a review of fiber, filler, and nanofiller addition

    PubMed Central

    Gad, Mohammed M; Fouda, Shaimaa M; Al-Harbi, Fahad A; Näpänkangas, Ritva; Raustia, Aune

    2017-01-01

    This paper reviews acrylic denture base resin enhancement during the past few decades. Specific attention is given to the effect of fiber, filler, and nanofiller addition on poly(methyl methacrylate) (PMMA) properties. The review is based on scientific reviews, papers, and abstracts, as well as studies concerning the effect of additives, fibers, fillers, and reinforcement materials on PMMA, published between 1974 and 2016. Many studies have reported improvement of PMMA denture base material with the addition of fillers, fibers, nanofiller, and hybrid reinforcement. However, most of the studies were limited to in vitro investigations without bioactivity and clinical implications. Considering the findings of the review, there is no ideal denture base material, but the properties of PMMA could be improved with some modifications, especially with silanized nanoparticle addition and a hybrid reinforcement system. PMID:28553115

  1. Color Stability of Heat-cure Acrylic Resin Subjected to Simulated Short-term Immersion in Fast-acting Denture Cleansers.

    PubMed

    Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B

    2016-01-01

    Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.

  2. Evaluation of the durability and antiadhesive action of 2-methacryloyloxyethyl phosphorylcholine grafting on an acrylic resin denture base material.

    PubMed

    Takahashi, Nana; Iwasa, Fuminori; Inoue, Yuuki; Morisaki, Hirobumi; Ishihara, Kazuhiko; Baba, Kazuyoshi

    2014-08-01

    The polymer 2-methacryloyloxyethyl phosphorylcholine is currently used on medical devices to prevent infection. Denture plaque-associated infection is regarded as a source of serious dental and medical complications in the elderly population, and denture hygiene, therefore, is an issue of considerable importance for denture wearers. Furthermore, because denture bases are exposed to mechanical stresses, for example, denture brushing, the durability of the coating is important for retaining the antiadhesive function of 2-methacryloyloxyethyl phosphorylcholine. The purpose of this study is to investigate the durability and antiadhesive activity of two 2-methacryloyloxyethyl phosphorylcholine polymer coating techniques: poly-2-methacryloyloxyethyl phosphorylcholine grafting and poly-2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate coating. It was revealed that 2-methacryloyloxyethyl phosphorylcholine polymer coating of the denture base resin polymethyl methacrylate decreases bacterial biofilm formation. Durability was examined by rhodamine staining and elemental surface analysis and by determining the wetting properties of the 2-methacryloyloxyethyl phosphorylcholine polymer-modified polymethyl methacrylate after a friction test that comprised 500 brushing cycles. Antiadhesive activity was examined by using a Streptococcus mutans biofilm formation assay. Poly-2-methacryloyloxyethyl phosphorylcholine-grafted polymethyl methacrylate retained 2-methacryloyloxyethyl phosphorylcholine units and antiadhesive activity even after repetitive mechanical stress, whereas co-n-butyl methacrylate-coated polymethyl methacrylate did not. These results demonstrated that graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on denture surfaces may contribute to the durability of the coating and prevent microbial retention. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. CAD/CAM complete dentures: a review of two commercial fabrication systems.

    PubMed

    Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z

    2013-06-01

    The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.

  4. Analysis of the effects of removable dentures on the psychological status, quality of life, and masticatory function of the elderly

    NASA Astrophysics Data System (ADS)

    Dyas, R.; Nathanael, M.; Indrasari, M.; Masulili, C.; Rahardjo, T. B.; Agustin, D.; Hogervorst, E.; Kusdhany, L.

    2017-08-01

    Older age is a major risk factor for diseases of the teeth and mouth and dementia. Diseases of the teeth and mouth can lead to tooth loss. The use of removable dentures can help the elderly to replace lost teeth; therefore, dentures are expected to improve the masticatory function, quality of life, and psychological status of the elderly. The aim of this study was to analyze the effects of removable denture usage on the improvement of the psychological status, quality of life, and masticatory function of elderly people. The data was obtained from 30 respondents. The patients answered questionnaires before they used the dentures, 2 weeks after they began using dentures, and 2 months after they started wearing dentures. Four different questionnaires were used: EuroQol Five Dimensions questionnaire (EQ-5D) and Geriatric Depression Scale (GDS), to measure psychological status; a mastication questionnaire to measure masticatory function; and a validated quality of life questionnaire. Based on the results of this study, it is clear that after 2 months of denture usage, removable dentures in the elderly can significantly improve their quality of life, masticatory function, and psychological status(p<0.05).

  5. A Clinical Evaluation Denture Adhesives Used by Patients With Xerostomia

    PubMed Central

    Bogucki, Zdzislaw A.; Napadlek, Piotr; Dabrowa, Tomasz

    2015-01-01

    Abstract The purpose of study was to analyze the participants’ opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia. PMID:25700320

  6. Study protocol for a multi-center, randomized controlled trial to develop Japanese denture adhesive guidelines for patients with complete dentures: the Denture Adhesive Guideline trial: study protocol for a randomized controlled trial.

    PubMed

    Kimoto, Suguru; Kawai, Yasuhiko; Gunji, Atsuko; Kondo, Hisatomo; Nomura, Taro; Murakami, Tomohiko; Tsuboi, Akito; Hong, Guang; Minakuchi, Shunsuke; Sato, Yusuke; Ohwada, Gaku; Suzuki, Tetsuya; Kimoto, Katsuhiko; Hoshi, Noriyuki; Saita, Makiko; Yoneyama, Yoshikazu; Sato, Yohei; Morokuma, Masakazu; Okazaki, Joji; Maeda, Takeshi; Nakai, Kenichiro; Ichikawa, Tetsuo; Nagao, Kan; Fujimoto, Keiko; Murata, Hiroshi; Kurogi, Tadafumi; Yoshida, Kazuhiro; Nishimura, Masahiro; Nishi, Yasuhiro; Murakami, Mamoru; Hosoi, Toshio; Hamada, Taizo

    2016-10-18

    Denture adhesives, characterized as medical products in 1935 by the American Dental Association, have been considered useful adjuncts for improving denture retention and stability. However, many dentists in Japan are hesitant to acknowledge denture adhesives in daily practice because of the stereotype that dentures should be inherently stable, without the aid of adhesives. The aim of this study is to verify the efficacy of denture adhesives to establish guidelines for Japanese users. The null hypothesis is that the application of denture adhesives, including the cream and powder types, or a control (isotonic sodium chloride solution) would not produce different outcomes nor would they differentially improve the set outcomes between baseline and day 4 post-application. This ten-center, randomized controlled trial with parallel groups is ongoing. Three hundred edentulous patients with complete dentures will be allocated to three groups (cream-type adhesive, powder-type adhesive, and control groups). The participants will wear their dentures with the denture adhesive for 4 days, including during eight meals (three breakfasts, two lunches, and three dinners). The baseline measurements and final measurements for the denture adhesives will be performed on the first day and after breakfast on the fourth day. The primary outcome is a general satisfaction rating for the denture. The secondary outcomes are denture satisfaction ratings for various denture functions, occlusal bite force, resistance to dislodgement, masticatory performance, perceived chewing ability, and oral health-related quality of life. Between-subjects comparisons among the three groups and within-subjects comparisons of the pre- and post-intervention measurements will be performed. Furthermore, a multiple regression analysis will be performed. The main analyses will be based on the intention-to-treat principle. A sample size of 100 subjects per group, including an assumed dropout rate of 10 %, will be required to achieve 80 % power with a 5 % alpha level. This randomized clinical trial will provide information about denture adhesives to complete denture wearers, prosthodontic educators, and dentists in Japan. We believe this new evidence on denture adhesive use from Japan will aid dentists in their daily practice even in other countries. ClinicalTrials.gov NCT01712802 . Registered on 17 October 2012.

  7. Influence of inner circular sealing area impression method on the retention of complete dentures.

    PubMed

    Wang, Cun-Wei; Shao, Qi; Sun, Hui-Qiang; Mao, Meng-Yun; Zhang, Xin-Wei; Gong, Qi; Xiao, Guo-Ning

    2015-01-01

    The aims of the present study were to describe an impression method of "inner circular sealing area" and to evaluate the effect of the method on retention, aesthetics and comfort of complete dentures, which lack labial base for patients with maxillary protrusions. Three patients were subjected to the experiment, and two sets of complete maxillary dentures were made for each patient; the first set was made without labial base via an inner circular sealing area method (experimental group) and the second had an intact base that was made with conventional methods (control group). Retention force tests were implemented with a tensile strength assessment device to assess the retention and a visual analogue scale (VAS) was used to evaluate the comfort between the two groups. Results showed larger retention force, better aesthetics and more comfort in the experimental group. The improved two-step impression method formed an inner circular sealing area that prevented damage to the peripheral border seal effect of the denture caused by incomplete bases and obtained better denture retention.

  8. Adhesion properties in systems of laminated pigmented polymers, carbon-graphite fiber composite framework and titanium surfaces in implant suprastructures.

    PubMed

    Segerström, Susanna; Ruyter, I Eystein

    2009-09-01

    For long-term stability the adhering interfaces of an implant-retained supraconstruction of titanium/carbon-graphite fiber-reinforced (CGFR) polymer/opaquer layer/denture base polymer/denture teeth must function as a unity. The aim was to evaluate adhesion of CGFR polymer to a titanium surface or CGFR polymer to two different opaquer layers/with two denture base polymers. Titanium plates were surface-treated and silanized and combined with a bolt of CGFR polymer or denture base polymer (Probase Hot). Heat-polymerized plates of CGFR polymer (47 wt% fiber) based on poly(methyl methacrylate) and a copolymer matrix were treated with an opaquer (Sinfony or Ropak) before a denture base polymer bolt was attached (Probase Hot or Lucitone 199). All specimens were heat-polymerized, water saturated (200 days) and thermally cycled (5000 cycles, 5/55 degrees C) before shear bond testing. Silicatized titanium surfaces gave higher bond strength to CGFR polymer (16.2+/-2.34 and 18.6+/-1.32) MPa and cohesive fracture than a sandblasted surface (5.9+/-2.11) MPa where the fracture was adhesive. The opaquer Sinfony gave higher adhesion values and mainly cohesive fractures than the opaquer Ropak. Different surface treatments (roughened or polished) of the CGFR polymer had no effect on bond strength. The fracture surfaces of silicatized titanium/CGFR polymer/opaquer layer (Sinfony)/denture base polymers were mainly cohesive. A combination of these materials in an implant-retained supraconstruction is promising for in vivo evaluation.

  9. Tensile Bond Strength between Soft Liners and Two Chemically Different Denture Base Materials: Effect of Thermocycling.

    PubMed

    Tugut, Faik; Coskun, Mehmet Emre; Dogan, Derya Ozdemir; Kirmali, Omer; Akin, Hakan

    2016-06-01

    The bond strength of soft denture liner to a recently introduced denture base resin after thermocycling has not been compared to traditional denture base materials. The objective of this study was to investigate the effects of thermocycling on the tensile bond strength of soft denture liners to two chemically different denture base resins, polymethyl methacrylate (PMMA) and urethane dimethacrylate (UDMA). A total of 48 PMMA and UDMA tensile test specimens were fabricated by attaching two different soft denture liners (Molloplast-B, Permaflex) according to the manufacturers' instructions and assigned to two groups. Half of the specimens for each group were stored in water for 1 week, and the other half were thermocycled (5000 cycles) between baths of 5°C and 55°C. Specimens were mounted on a universal testing machine with a 5 mm/min crosshead speed. The data were analyzed with three-way ANOVA and post hoc Tukey-Kramer multiple comparisons tests (α = 0.05). The highest bond strength was measured in the specimens from the UDMA/Molloplast groups, and the lowest was seen in the PMMA/Permaflex group. No significant difference in bond strength was detected in PMMA/Permaflex groups after thermocycling (p = 0.082), whereas other groups exhibited significant differences after thermocycling (p < 0.05). Thermocycling decreased the bond strength values in both the PMMA and UDMA groups. Regardless of types of soft liners, PMMA specimens presented lower bond strength values than UDMA specimens, both before and after thermocycling. © 2015 by the American College of Prosthodontists.

  10. In-situ monitoring of curing and ageing effects in FRP plates using embedded FBG sensors

    NASA Astrophysics Data System (ADS)

    Xian, Guijun; Wang, Chuan; Li, Hui

    2010-04-01

    In recent years, fiber reinforced polymer (FRP) composites have been widely applied in civil engineering for retrofitting or renewal of existing structures. Since FRP composite may degrade when exposed to severe outdoor environments, a serious concern has been raised on its long term durability. In the present study, fiber Bragg grating (FBG) sensors were embedded in glass-, carbon- and basalt-fiber reinforced epoxy based FRP plates with wet lay-up technology, to in-situ monitor the stain changes in FRPs during the curing, and water immersion and freeze-thaw ageing processes. The study demonstrates that the curing of epoxy resin brings in a slight tension strain (e.g., 10 ~ 30 μɛ) along the fiber direction and a high contraction (e.g., ~ 1100μɛ) in the direction perpendicular to the fibers, mainly due to the resin shrinkage. The cured FRP strips were then subjected to distilled water immersion at 80oC and freeze-thaw cycles from -30°C to 30°C. Remarkable strain changes of FRPs due to the variation of the temperatures during freeze-thaw cycles indicate the potential property degradation from fatigue. The maximum strain change is dependent on the fiber types and directions to the fiber. Based on the monitored strain values with temperature change and water uptake content, CTE (coefficient of thermal expansion) and CME (coefficient of moisture expansion) are exactly determined for the FRPs.

  11. Detection method of flexion relaxation phenomenon based on wavelets for patients with low back pain

    NASA Astrophysics Data System (ADS)

    Nougarou, François; Massicotte, Daniel; Descarreaux, Martin

    2012-12-01

    The flexion relaxation phenomenon (FRP) can be defined as a reduction or silence of myoelectric activity of the lumbar erector spinae muscle during full trunk flexion. It is typically absent in patients with chronic low back pain (LBP). Before any broad clinical utilization of this neuromuscular response can be made, effective, standardized, and accurate methods of identifying FRP limits are needed. However, this phenomenon is clearly more difficult to detect for LBP patients than for healthy patients. The main goal of this study is to develop an automated method based on wavelet transformation that would improve time point limits detection of surface electromyography signals of the FRP in case of LBP patients. Conventional visual identification and proposed automated methods of time point limits detection of relaxation phase were compared on experimental data using criteria of accuracy and repeatability based on physiological properties. The evaluation demonstrates that the use of wavelet transform (WT) yields better results than methods without wavelet decomposition. Furthermore, methods based on wavelet per packet transform are more effective than algorithms employing discrete WT. Compared to visual detection, in addition to demonstrating an obvious saving of time, the use of wavelet per packet transform improves the accuracy and repeatability in the detection of the FRP limits. These results clearly highlight the value of the proposed technique in identifying onset and offset of the flexion relaxation response in LBP subjects.

  12. Quasi-plane-hypothesis of strain coordination for RC beams seismically strengthened with externally-bonded or near-surface mounted fiber reinforced plastic

    NASA Astrophysics Data System (ADS)

    Ren, Zhenhua; Zeng, Xiantao; Liu, Hanlong; Zhou, Fengjun

    2013-03-01

    The application of fiber reinforced plastic (FRP), including carbon FRP and glass FRP, for structural repair and strengthening has grown due to their numerous advantages over conventional materials such as externally bonded reinforcement (EBR) and near-surface mounted (NSM) strengthening techniques. This paper summarizes the results from 21 reinforced concrete beams strengthened with different methods, including externally-bonded and near-surface mounted FRP, to study the strain coordination of the FRP and steel rebar of the RC beam. Since there is relative slipping between the RC beam and the FRP, the strain of the FRP and steel rebar of the RC beam satisfy the quasi-plane-hypothesis; that is, the strain of the longitudinal fiber that parallels the neutral axis of the plated beam within the scope of the effective height ( h 0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. The strain of the FRP and steel rebar satisfies the equation: ɛ FRP= βɛ steel, and the value of β is equal to 1.1-1.3 according to the test results.

  13. Forensic odontology: A prosthodontic view

    PubMed Central

    Gosavi, Sulekha; Gosavi, Siddharth

    2012-01-01

    The most common role of the forensic dentist is the identification of deceased individuals. Dental identifications have always played a key role in natural and manmade disaster situations, and in particular, the mass casualties normally associated with aviation disasters. Because of the lack of a comprehensive fingerprint database, dental identification continues to be crucial in the world. An all-acrylic resin appliance such as a full denture or an all-acrylic partial denture (or orthodontic appliance), prior to delivery, could be inscribed with the patient's full name on a substrate (paper, metal) and sealed inconspicuously into the surface of a denture by various processes. It has been noted by several authors that in many cases of air disaster where the limbs are completely burnt off, some denture materials survive, especially the posterior part of acrylic dentures and metal-based dentures. Thus, marked dental prostheses (full and partial dentures, mouthguards and removal orthodontic appliances) would lead to rapid identification in the event of accidents and disaster. PMID:23087581

  14. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles, task 3 - FRP composite pile flexural testing.

    DOT National Transportation Integrated Search

    2014-06-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP : composite piles for load-bearing in bridges. This report covers Task 3, FRP Composite Pile Flexural Testing. : Hollow and concrete filled...

  15. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles, task 6 - FRP composite pile axial compression testing.

    DOT National Transportation Integrated Search

    2015-04-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP : composite piles for load-bearing in bridges. This report covers Task 6, FRP Composite Pile Axial Compression : Testing. : Hollow and conc...

  16. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles, task 1 - mechanical properties of FRP piles.

    DOT National Transportation Integrated Search

    2014-10-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP : composite piles for load-bearing in bridges. This report covers Task 1, Mechanical Properties of FRP Piles. : Mechanical and geotechnic...

  17. Evaluate the Effect of Commercially Available Denture Cleansers on Surface Hardness and Roughness of Denture Liners at Various Time Intervals

    PubMed Central

    Mohammed, Hilal S.; Singh, Sumeet; Hari, Prasad A.; Amarnath, G. S.; Kundapur, Vinaya; Pasha, Naveed; Anand, M.

    2016-01-01

    Background and objective: Chemical cleansing by denture cleansers is first choice for denture plaque control. The most common problems while using denture cleansers are hardening, porosity, odor sorption, water sorption, solubility, and colour change, bacterial and fungal growth. Chemical cleansing procedures have been found to have an effect on the physical and mechanical properties of denture liners. Thus, this study was conducted to evaluate the effect of commercially available denture cleansers on surface hardness and roughness of acrylic and silicon based denture liners at various time interval. Method: Two autopolymerising denture liners Kooliner (acrylic) and GC reline soft (silicon) were tested with two commercially available denture cleansers, polident and efferdent plus. Total of 120 specimens were prepared and all the specimens were divided into six groups based on the relining materials and denture cleansers used. Surface hardness and surface roughness was tested using Shore A durometer and profilometer respectively at the end of day 1, day 7, day 30 and day 90. All the specimens were stored in artificial saliva throughout the study. Cleanser solution was prepared daily by adding Polident and Efferdent plus denture cleanser tablet into 250ml of enough very warm (not hot) water. Acrylic and silicon liner groups were cleansed in a solution of denture cleanser and water for 15 minutes daily, rinsed with water and stored in artificial saliva at room temperature. The data was analyzed with one way ANOVA and independent t-test. Result: The acrylic soft lining showed gradual hardening and increase in surface roughness after immersion in denture cleanser and also with time. Acrylic liner material showed maximum hardness and roughness with Polident followed by Efferdent plus and water (control group). Silicone lining material showed a slight difference in hardness and roughness between the test group and control group. There was a slight increase in hardness in all the groups with time. Very slight increase in mean surface roughness of all the silicon liner groups from day 1 to day 90 was observed. A statistically significant change was noted between and within the all silicon liner groups on day 7, day 30 and day 90. Conclusion: The average surface hardness and surface roughness were lower in silicon liner material than acrylic liner material. Maximum surface roughness was noted by Polident followed by Efferdent Plus and Water for both acrylic liner group and silicon liner group. PMID:28190983

  18. Microtensile bond strength of different acrylic teeth to high-impact denture base resins.

    PubMed

    Colebeck, Amanda C; Monaco, Edward A; Pusateri, Christopher R; Davis, Elaine L

    2015-01-01

    This study evaluated the effect of denture base acrylic, denture tooth composition, and ridge-lap surface treatment on the microtensile bond strength (μTBS) of three commercially available denture teeth and two injection denture processing systems. Sixteen experimental groups were formed (n = 3), according to denture tooth surface treatment (no treatment or surface treatment recommended by the manufacturer), denture base processing technique and acrylic (SR-Ivocap-Ivocap Plus or Success-Lucitone 199), and tooth type-composition at bonding interface (BlueLine DCL-PMMA, Portrait IPN-PMMA, Phonares II-PMMA, Phonares II-NHC). Rectangular bar specimens with a 1 mm(2) cross sectional area were fabricated and subsequently thermocycled at 10,000 cycles between 5°C and 55°C with a 15-second dwell time. Select specimens underwent μTBS testing in a universal testing machine with a 1 kN load cell at 0.5 mm/min crosshead speed. Data were analyzed statistically by two and three-way ANOVA and Tukey post hoc test (α = 0.05). Mean μTBS ranged between 56.2 ± 5.6 and 60.8 ± 5.0 N/mm(2) for the Ivocap Plus specimens and 13.3 ± 5.12 to 60.1 ± 6.0 N/mm(2) for the Lucitone 199 specimens. Among the Ivocap specimens, BlueLine DCL and Phonares II NHC had significantly higher μTBS than Portrait IPN to Ivocap Plus acrylic. There were no statistically significant differences among Blueline, Phonares II PMMA, and Phonares II NHC, or between Phonares II PMMA and Portrait IPN. Within the Luctione 199 specimens, there was a significantly higher μTBS for BlueLine DCL and Phonares II NHC denture teeth with the manufacturer-recommended surface treatment when compared to control surface. BlueLine, Portrait, and Phonares II PMMA groups achieved significantly higher mean μTBS than the Phonares II NHC group. There were no statistically significant differences among BlueLine, Portrait, and Phonares II PMMA groups. When evaluating the μTBS of PMMA and NHC denture teeth to base resins, a stronger bond was achieved using materials produced by the same manufacturer. Within the Luctione 199 specimens, the Phonares II NHC group demonstrated significantly lower bond strength than other specimens, suggesting that gross ridge-lap reduction of NHC denture teeth is not recommended if a base acrylic by a different manufacturer from the tooth is going to be used. © 2014 American College of Prosthodontists.

  19. Quantifying atmospheric pollutant emissions from open biomass burning with multiple methods: a case study for Yangtze River Delta region, China

    NASA Astrophysics Data System (ADS)

    Yang, Y.; Zhao, Y.

    2017-12-01

    To understand the differences and their origins of emission inventories based on various methods for the source, emissions of PM10, PM2.5, OC, BC, CH4, VOCs, CO, CO2, NOX, SO2 and NH3 from open biomass burning (OBB) in Yangtze River Delta (YRD) are calculated for 2005-2012 using three (bottom-up, FRP-based and constraining) approaches. The inter-annual trends in emissions with FRP-based and constraining methods are similar with the fire counts in 2005-2012, while that with bottom-up method is different. For most years, emissions of all species estimated with constraining method are smaller than those with bottom-up method (except for VOCs), while they are larger than those with FRP-based (except for EC, CH4 and NH3). Such discrepancies result mainly from different masses of crop residues burned in the field (CRBF) estimated in the three methods. Among the three methods, the simulated concentrations from chemistry transport modeling with the constrained emissions are the closest to available observations, implying the result from constraining method is the best estimation for OBB emissions. CO emissions in the three methods are compared with other studies. Similar temporal variations were found for the constrained emissions, FRP-based emissions, GFASv1.0 and GFEDv4.1s, with the largest and the lowest emissions estimated for 2012 and 2006, respectively. The constrained CO emissions in this study are smaller than those in other studies based on bottom-up method and larger than those based on burned area and FRP derived from satellite. The contributions of OBB to two particulate pollution events in 2010 and 2012 are analyzed with the brute-force method. The average contribution of OBB to PM10 mass concentrations in June 8-14 2012 was estimated at 38.9% (74.8 μg m-3), larger than that in June 17-24, 2010 at 23.6 % (38.5 μg m-3). Influences of diurnal curves and meteorology on air pollution caused by OBB are also evaluated, and the results suggest that air pollution caused by OBB will become heavier if the meteorological conditions are unfavorable, and that more attention should be paid to the supervision in night. Quantified with the Monte-Carlo simulation, the uncertainties of OBB emissions with constraining method are significantly lower than those with bottom-up or FRP-based methods.

  20. Bridge-in-a-Backpack(TM). Task 7 : investigation of damage and repairs for concrete filled FRP tubular arches.

    DOT National Transportation Integrated Search

    2015-04-01

    This report includes fulfillment of Task 7 of a multi-task contract to further enhance concrete filled FRP tubes, or : the Bridge in a Backpack. : Damage due to impact of the FRP shell of the concrete filled FRP tubular arch bridges has been and stil...

  1. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base

    PubMed Central

    Shinawi, Lana Ahmed

    2017-01-01

    Background The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. Aim To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. Methods This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. Results ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. Conclusion CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits. PMID:28713496

  2. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    PubMed

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  3. Large scale distribution monitoring of FRP-OF based on BOTDR technique for infrastructures

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; He, Jianping; Yan, Kai; Ou, Jinping

    2007-04-01

    BOTDA(R) sensing technique is considered as one of the most practical solution for large-sized structures as the instrument. However, there is still a big obstacle to apply BOTDA(R) in large-scale area due to the high cost and the reliability problem of sensing head which is associated to the sensor installation and survival. In this paper, we report a novel low-cost and high reliable BOTDA(R) sensing head using FRP(Fiber Reinforced Polymer)-bare optical fiber rebar, named BOTDA(R)-FRP-OF. We investigated the surface bonding and its mechanical strength by SEM and intensity experiments. Considering the strain difference between OF and host matrix which may result in measurement error, the strain transfer from host to OF have been theoretically studied. Furthermore, GFRP-OFs sensing properties of strain and temperature at different gauge length were tested under different spatial and readout resolution using commercial BOTDA. Dual FRP-OFs temperature compensation method has also been proposed and analyzed. And finally, BOTDA(R)-OFs have been applied in Tiyu west road civil structure at Guangzhou and Daqing Highway. This novel FRP-OF rebar shows both high strengthen and good sensing properties, which can be used in long-term SHM for civil infrastructures.

  4. Structural Behavior of Concrete Beams Reinforced with Basalt Fiber Reinforced Polymer (BFRP) Bars

    NASA Astrophysics Data System (ADS)

    Ovitigala, Thilan

    The main challenge for civil engineers is to provide sustainable, environmentally friendly and financially feasible structures to the society. Finding new materials such as fiber reinforced polymer (FRP) material that can fulfill the above requirements is a must. FRP material was expensive and it was limited to niche markets such as space shuttles and air industry in the 1960s. Over the time, it became cheaper and spread to other industries such as sporting goods in the 1980-1990, and then towards the infrastructure industry. Design and construction guidelines are available for carbon fiber reinforced polymer (CFRP), aramid fiber reinforced polymer (AFRP) and glass fiber reinforced polymer (GFRP) and they are currently used in structural applications. Since FRP is linear elastic brittle material, design guidelines for the steel reinforcement are not valid for FRP materials. Corrosion of steel reinforcement affects the durability of the concrete structures. FRP reinforcement is identified as an alternative to steel reinforcement in corrosive environments. Although basalt fiber reinforced polymer (BFRP) has many advantages over other FRP materials, but limited studies have been done. These studies didn't include larger BFRP bar diameters that are mostly used in practice. Therefore, larger beam sizes with larger BFRP reinforcement bar diameters are needed to investigate the flexural and shear behavior of BFRP reinforced concrete beams. Also, shear behavior of BFRP reinforced concrete beams was not yet studied. Experimental testing of mechanical properties and bond strength of BFRP bars and flexural and shear behavior of BFRP reinforced concrete beams are needed to include BFRP reinforcement bars in the design codes. This study mainly focuses on the use of BFRP bars as internal reinforcement. The test results of the mechanical properties of BFRP reinforcement bars, the bond strength of BFRP reinforcement bars, and the flexural and shear behavior of concrete beams reinforced with BFRP reinforcement bars are presented and verified with other research studies, existing design codes and guidelines provided for other FRP bars. Based on the experimental testing results, analytical equations were developed and existing equations were modified to predict the actual structural behavior of FRP bar reinforced concrete beams with reasonable accuracy.

  5. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles, task 2 - FRP composite pile driving at the Richmond-Dresden bridge over the Kennebec River.

    DOT National Transportation Integrated Search

    2014-01-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP : composite piles for load-bearing in bridges. This report covers Task 2, FRP Composite Pile Driving at the : Richmond-Dresden Bridge over ...

  6. Fracture Surface Analysis of Clinically Failed Fixed Partial Dentures

    PubMed Central

    Taskonak, B.; Mecholsky, J.J.; Anusavice, K.J.

    2008-01-01

    Ceramic systems have limited long-term fracture resistance, especially when they are used in posterior areas or for fixed partial dentures. The objective of this study was to determine the site of crack initiation and the causes of fracture of clinically failed ceramic fixed partial dentures. Six Empress 2® lithia-disilicate (Li2O·2SiO2)-based veneered bridges and 7 experimental lithia-disilicate-based non-veneered ceramic bridges were retrieved and analyzed. Fractography and fracture mechanics methods were used to estimate the stresses at failure in 6 bridges (50%) whose fracture initiated from the occlusal surface of the connectors. Fracture of 1 non-veneered bridge (8%) initiated within the gingival surface of the connector. Three veneered bridges fractured within the veneer layers. Failure stresses of the all-core fixed partial dentures ranged from 107 to 161 MPa. Failure stresses of the veneered fixed partial dentures ranged from 19 to 68 MPa. We conclude that fracture initiation sites are controlled primarily by contact damage. PMID:16498078

  7. Concrete Infill Monitoring in Concrete-Filled FRP Tubes Using a PZT-Based Ultrasonic Time-of-Flight Method.

    PubMed

    Luo, Mingzhang; Li, Weijie; Hei, Chuang; Song, Gangbing

    2016-12-07

    Concrete-filled fiber-reinforced polymer tubes (CFFTs) have attracted interest for their structural applications in corrosive environments. However, a weak interfacial strength between the fiber-reinforced polymer (FRP) tube and the concrete infill may develop due to concrete shrinkage and inadequate concrete compaction during concrete casting, which will destroy the confinement effect and thereby reduce the load bearing capacity of a CFFT. In this paper, the lead zirconate titanate (PZT)-based ultrasonic time-of-flight (TOF) method was adopted to assess the concrete infill condition of CFFTs. The basic idea of this method is that the velocity of the ultrasonic wave propagation in the FRP material is about half of that in concrete material. Any voids or debonding created along the interface between the FRP tube and the concrete will delay the arrival time between the pairs of PZT transducers. A comparison of the arrival times of the PZT pairs between the intact and the defected CFFT was made to assess the severity of the voids or the debonding. The feasibility of the methodology was analyzed using a finite-difference time-domain-based numerical simulation. Experiments were setup to validate the numerical results, which showed good agreement with the numerical findings. The results showed that the ultrasonic time-of-flight method is able to detect the concrete infill condition of CFFTs.

  8. Concrete Infill Monitoring in Concrete-Filled FRP Tubes Using a PZT-Based Ultrasonic Time-of-Flight Method

    PubMed Central

    Luo, Mingzhang; Li, Weijie; Hei, Chuang; Song, Gangbing

    2016-01-01

    Concrete-filled fiber-reinforced polymer tubes (CFFTs) have attracted interest for their structural applications in corrosive environments. However, a weak interfacial strength between the fiber-reinforced polymer (FRP) tube and the concrete infill may develop due to concrete shrinkage and inadequate concrete compaction during concrete casting, which will destroy the confinement effect and thereby reduce the load bearing capacity of a CFFT. In this paper, the lead zirconate titanate (PZT)-based ultrasonic time-of-flight (TOF) method was adopted to assess the concrete infill condition of CFFTs. The basic idea of this method is that the velocity of the ultrasonic wave propagation in the FRP material is about half of that in concrete material. Any voids or debonding created along the interface between the FRP tube and the concrete will delay the arrival time between the pairs of PZT transducers. A comparison of the arrival times of the PZT pairs between the intact and the defected CFFT was made to assess the severity of the voids or the debonding. The feasibility of the methodology was analyzed using a finite-difference time-domain-based numerical simulation. Experiments were setup to validate the numerical results, which showed good agreement with the numerical findings. The results showed that the ultrasonic time-of-flight method is able to detect the concrete infill condition of CFFTs. PMID:27941617

  9. Potential pathogenic aspects of denture plaque.

    PubMed

    Coulthwaite, L; Verran, J

    2007-01-01

    Oral health status declines with age and as a result the need for removable prostheses increases. Oral health is a reflection of one's general health, affecting the ability of an individual to eat and speak, and contributes significantly to a sense of confidence and well-being. Currently, there are 15 million denture wearers in the UK, representing a significant consumer base and a special healthcare consideration. The microbiology of denture plaque has received little attention in comparison with dental plaque, yet it differs in location and composition. Denture plaque and poor denture hygiene is associated with stomatitis (Candida infection), may also serve as a reservoir of potentially infectious pathogens, and may contribute to oral malodour and to caries and periodontitis in people who have remaining natural teeth. Oral bacteria have been implicated in bacterial endocarditis, aspiration pneumonia, gastrointestinal infection and chronic obstructive pulmonary disease, among others, and dentures offer a reservoir for microorganisms associated with these infections. An effective oral hygiene regimen is important to control denture plaque biofilm and contributes to the control of associated oral and systemic diseases.

  10. In Vitro Evaluation of the Inhibitory Activity of Thymoquinone in Combatting Candida albicans in Denture Stomatitis Prevention

    PubMed Central

    Al-Khalifa, Khalifa S.; Gad, Mohammed M.; Al-Hariri, Mohammed; Alnassar, Talal

    2017-01-01

    Candida albicans adhesion and proliferation on denture bases may lead to denture stomatitis, which is a common and recurrent problem in denture wearers. The goal of this study was to assess the inhibitory effect of thymoquinone incorporated in the polymethyl methacrylate denture base material against Candida albicans. Eighty acrylic resin specimens were fabricated and divided into eight groups (n = 10) according to thymoquinone concentrations of 0.5%, 1%, 1.5%, 2%, 2.5%, 3%, and 5% of acrylic powder. Two methods were used to evaluate the effect of thymoquinone on Candida albicans: the slide count and the serial dilution test. A multivariate analysis of variance (MANOVA) and the post-hoc Tukey’s Honestly Significant Difference (HSD) test were performed to compare the difference of means between the observations taken at various intervals with baseline. The p value was statistically significant at ≤0.05. According to the slide count and the serial dilution test, the mean number of adhered Candida albicans in the control group was 5436.9 ± 266 and 4691.4 ± 176.8; however, this number dramatically decreased to 0 ± 0 and 32.4 ± 1.7 in group 8 (concentration 5%). These results suggest that the incorporation of thymoquinone into the acrylic resin denture base material might be effective in preventing Candida albicans adhesion. PMID:28698449

  11. New generation fiber reinforced polymer composites incorporating carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Soliman, Eslam

    The last five decades observed an increasing use of fiber reinforced polymer (FRP) composites as alternative construction materials for aerospace and infrastructure. The high specific strength of FRP attracted its use as non-corrosive reinforcement. However, FRP materials were characterized with a relatively low ductility and low shear strength compared with steel reinforcement. On the other hand, carbon nanotubes (CNTs) have been introduced in the last decade as a material with minimal defect that is capable of increasing the mechanical properties of polymer matrices. This dissertation reports experimental investigations on the use of multi-walled carbon nanotubes (MWCNTs) to produce a new generation of FRP composites. The experiments showed significant improvements in the flexure properties of the nanocomposite when functionalized MWCNTs were used. In addition, MWCNTs were used to produce FRP composites in order to examine static, dynamic, and creep behavior. The MWCNTs improved the off-axis tension, off-axis flexure, FRP lap shear joint responses. In addition, they reduced the creep of FRP-concrete interface, enhanced the fracture toughness, and altered the impact resistance significantly. In general, the MWCNTs are found to affect the behaviour of the FRP composites when matrix failure dominates the behaviour. The improvement in the mechanical response with the addition of low contents of MWCNTs would benefit many industrial and military applications such as strengthening structures using FRP composites, composite pipelines, aircrafts, and armoured vehicles.

  12. An exact stiffness theory for unidirectional xFRP composites

    NASA Astrophysics Data System (ADS)

    Klasztorny, M.; Konderla, P.; Piekarski, R.

    2009-01-01

    UD xFRP composites, i.e., isotropic plastics reinforced with long transversely isotropic fibres packed unidirectionally according to the hexagonal scheme are considered. The constituent materials are geometrically and physically linear. The previous formulations of the exact stiffness theory of such composites are revised, and the theory is developed further based on selected boundary-value problems of elasticity theory. The numerical examples presented are focussed on testing the theory with account of previous variants of this theory and experimental values of the effective elastic constants. The authors have pointed out that the exact stiffness theory of UD xFRP composites, with the modifications proposed in our study, will be useful in the engineering practice and in solving the current problems of the mechanics of composite materials.

  13. Complete denture base assessments using holograms: dimensional alterations after different activation methods

    NASA Astrophysics Data System (ADS)

    Dughir, Ciprian; Popovschi, Ana Maria; Cojocariu, Andreea Codruta; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Sinescu, Cosmin; de Sabata, Aldo; Duma, Virgil-Florin

    2016-03-01

    Holography is a well-developed method with a large range of applications, including dentistry. This study uses holographic methods for the study of total dental prosthesis. The issue is that the transformation of wax denture base in polymethylacrylate causes dimensional alterations and retractions in the final dental constructs. These could cause the failure of the stability of the complete denture in the oral cavity. Thus, the aim of this study is to determine and to compare using holography, total prosthesis obtained using three different manufacturing methods: pressing, injection, and polymerization. Each of the three types of dentures thus produced were recorded over the previously wax complete base holographic plates. The dimensional alterations that appear after using the different activation methods were thus determined. The most significant modification was remarked in the custom press technology, while the smallest variations were detected in the injection alternative.

  14. A novel design solution to the fraenal notch of maxillary dentures.

    PubMed

    White, J A P; Bond, I P; Jagger, D C

    2013-09-01

    This study investigates a novel design feature for the fraenal notch of maxillary dentures, using computational and experimental methods, and shows that its use could significantly increase the longevity of the prosthesis. A two-step process can be used to create the design feature with current denture base materials, but would be highly dependent on the individual skill of the dental technician. Therefore, an alternative form of manufacture, multi-material additive layer manufacture (or '3D printing'), has been proposed as a future method for the direct production of complete dentures with multi-material design features.

  15. Use of Candida-specific chicken egg yolk antibodies to inhibit the adhering of Candida to denture base materials: prevention of denture stomatitis.

    PubMed

    Kamikawa, Yoshiaki; Fujisaki, Junichi; Nagayama, Tomohiro; Kawasaki, Kiyotsugu; Hirabayashi, Daisuke; Hamada, Tomofumi; Sakamoto, Ryoich; Mukai, Hiroshi; Sugihara, Kazumasa

    2016-09-01

    Polyclonal anti-Candida chicken egg yolk antibodies (anti-IgY) were used to investigate the prevention of adherence of Candida species to denture base material in vitro. Candida is a potential virulence factor that can cause systemic infection and even death in immunocompromised individuals. Because long-term antifungal treatment may lead to the emergence of drug-resistant strains, it is necessary to develop novel preventive measures and treatments for candidiasis. Three types of chicken egg yolk antibodies were used in this study: non-specific antibody (control IgY), Candida albicans-specific antibody (anti-C.a.IgY) and Candida glabrata-specific antibody (anti-C.g.IgY). A mixture of different dilutions of each antibody with a suspension of Candida species and denture base material was incubated for 3 h, and then the colony-forming units of Candida on the denture base material were counted. Compared with control IgY, anti-C.a.IgY and anti-C.g.IgY significantly inhibited the adherence of C. albicans, but anti-C.a.IgY tended to be more potent than anti-C.g.IgY. The adherence of C. glabrata was also inhibited significantly by anti-C.a.IgY and anti-C.g.IgY with almost equivalent potency, indicating that their actions against C. glabrata were comparable. This study revealed the inhibitory effects of anti-C.a.IgY and anti-C.g.IgY against the adherence of C. albicans and C. glabrata to denture base material. This finding indicates the possibility of a beneficial effect of IgYs for the prevention of denture stomatitis and candidiasis in clinical settings. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  16. Optimizing variable radius plot size and LiDAR resolution to model standing volume in conifer forests

    Treesearch

    Ram Kumar Deo; Robert E. Froese; Michael J. Falkowski; Andrew T. Hudak

    2016-01-01

    The conventional approach to LiDAR-based forest inventory modeling depends on field sample data from fixed-radius plots (FRP). Because FRP sampling is cost intensive, combining variable-radius plot (VRP) sampling and LiDAR data has the potential to improve inventory efficiency. The overarching goal of this study was to evaluate the integration of LiDAR and VRP data....

  17. A simplified chair-side remount technique using customized mounting platforms.

    PubMed

    Chauhan, Mamta Devendrakumar; Dange, Shankar Pandharinath; Khalikar, Arun Narayan; Vaidya, Smita Padmakar

    2012-08-01

    Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms.

  18. A simplified chair-side remount technique using customized mounting platforms

    PubMed Central

    Dange, Shankar Pandharinath; Khalikar, Arun Narayan; Vaidya, Smita Padmakar

    2012-01-01

    Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms. PMID:22977726

  19. Reinforcing effects of different fibers on denture base resin based on the fiber type, concentration, and combination.

    PubMed

    Yu, Sang-Hui; Lee, Yoon; Oh, Seunghan; Cho, Hye-Won; Oda, Yutaka; Bae, Ji-Myung

    2012-01-01

    The aim of this study was to evaluate the reinforcing effects of three types of fibers at various concentrations and in different combinations on flexural properties of denture base resin. Glass (GL), polyaromatic polyamide (PA) and ultra-high molecular weight polyethylene (PE) fibers were added to heat-polymerized denture base resin with volume concentrations of 2.6%, 5.3%, and 7.9%, respectively. In addition, hybrid fiber-reinforced composite (FRC) combined with either two or three types of fibers were fabricated. The flexural strength, modulus and toughness of each group were measured with a universal testing machine at a crosshead speed of 5 mm/min. In the single fiber-reinforced composite groups, the 5.3% GL and 7.9% GL had the highest flexural strength and modulus; 5.3% PE was had the highest toughness. Hybrid FRC such as GL/PE, which showed the highest toughness and the flexural strength, was considered to be useful in preventing denture fractures clinically.

  20. Development of Meteorological Towers Using Advanced Composite Materials

    NASA Astrophysics Data System (ADS)

    Alshurafa, Sami A.

    The research program involved both numerical and experimental work. The numerical analysis was conducted to simulate the static and dynamic behaviour of the 81 m meteorological FRP guyed tower under wind and ice loading. The FRP tower consisted of 16 segments each made of 3 cells connected together to form an equilateral triangle having equal sides of 450 mm. The segments were interconnected using internal sleeves. Various non-linear finite element models were developed to study a number of design parameters for the 81 m FRP tower such as, different laminates containing a variety of stacking sequences of laminate orientations with various thicknesses, different cable diameters, and appropriate guy cable spacing levels. The effect of pre-stressing the guy cables up to 10 % of their breaking strength was investigated. The effect of fibre volume fraction on the design of the FRP tower was also examined. Furthermore, an 8.6 m FRP tower segment was designed using the finite element analysis and subject to the same loading conditions experienced by the bottom section of the 81 m FRP tower. A modal analysis was carried out for both the 8.6 m FRP tower segment with and without a mass on the top as well as for the 81 m FRP guyed tower to evaluate the vibration performance of these towers. The experimental work involved extensive material testing to define the material properties for use in the analysis of the 81 m FRP tower. It also involved the design and fabrication of a special collapsible mandrel for fabricating the FRP cells for the 8.6 m tower segment. The 8.6 m tower was tested horizontally under static lateral loading to 80 % of its estimated failure load using a "whiffle tree" arrangement, in order to simulate a uniformly distributed wind loading. Later, the same FRP tower was erected in a vertical position and was tested with and without a mass on top under dynamic loading to obtain the natural frequencies. Lastly, a comparative study was conducted between two 81 m FRP towers having different fibre volume fractions and a steel tower having a circular cross section.

  1. Immunoexpression of vascular endothelial growth factor in gingival mucosa with papilloma and condyloma acuminata.

    PubMed

    Scrieciu, Monica; MercuŢ, Veronica; Andrei, Oana Cella; Predescu, Anca Mihaela; Niculescu, Mihaela; Pisoschi, Cătălina Gabriela; BaniŢă, Ileana Monica

    2015-01-01

    The histological changes of the oral mucosa in contact with a metal alloy dentures is one of the current issues widely debated in the literature. To highlight the expression of vascular endothelial growth factor (VEGF) in human paraprosthetic gingival mucosa exposed to nickel and copper compounds using the immunohistochemical technique. The selected participants were wearers of fixed dentures made of nickel-based alloys and copper-based alloys. The gingival mucosa fragments were prelevated through excision after removing fixed denture and extraction one of its affected teeth. The gingival mucosa fragments were processed through the histological technique of paraffin inclusion. The paraffin-embedded tissue sections were usually stained with Hematoxylin-Eosin and processed by immunohistochemical technique with VEGF antibody. The gingival mucosa fragments from nickel-based alloys dentures wearers were diagnosed with papilloma and, also, gingival mucosa samples prelevated from copper-based alloys dentures wearers were diagnosed with condyloma acuminata. Immunohistochemical reaction for VEGF was different in the gingival mucosa fragments with papilloma compared with condyloma acuminata samples. In papillomatosis gingival mucosa fragments, VEGF was implicated in principal in vasodilatation and inflammation process, and secondary in angiogenesis. In gingival mucosa fragments with condyloma acuminata, the principal role of VEGF was in angiogenesis and secondary in inflammation.

  2. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

    PubMed Central

    2014-01-01

    PURPOSE This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and 100 µL of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at 37℃ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. RESULTS PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. CONCLUSION This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required. PMID:25006385

  3. Strengthening of reinforced concrete beams with basalt-based FRP sheets: An analytical assessment

    NASA Astrophysics Data System (ADS)

    Nerilli, Francesca; Vairo, Giuseppe

    2016-06-01

    In this paper the effectiveness of the flexural strengthening of RC beams through basalt fiber-reinforced sheets is investigated. The non-linear flexural response of RC beams strengthened with FRP composites applied at the traction side is described via an analytical formulation. Validation results and some comparative analyses confirm soundness and consistency of the proposed approach, and highlight the good mechanical performances (in terms of strength and ductility enhancement of the beam) produced by basalt-based reinforcements in comparison with traditional glass or carbon FRPs.

  4. Strengthening of reinforced concrete beams with basalt-based FRP sheets: An analytical assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nerilli, Francesca; Vairo, Giuseppe

    2016-06-08

    In this paper the effectiveness of the flexural strengthening of RC beams through basalt fiber-reinforced sheets is investigated. The non-linear flexural response of RC beams strengthened with FRP composites applied at the traction side is described via an analytical formulation. Validation results and some comparative analyses confirm soundness and consistency of the proposed approach, and highlight the good mechanical performances (in terms of strength and ductility enhancement of the beam) produced by basalt-based reinforcements in comparison with traditional glass or carbon FRPs.

  5. Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.

    PubMed

    Goto, Takaharu; Nagao, Kan; Ishida, Yuichi; Tomotake, Yoritoki; Ichikawa, Tetsuo

    2015-02-01

    This in vitro study investigated the effect of attachment installation conditions on the load transfer and denture movements of implant overdentures, and aims to clarify the differences among the three types of attachments, namely ball, Locator, and magnet attachments. Three types of attachments, namely ball, Locator, and magnetic attachments were used. An acrylic resin mandibular edentulous model with two implants placed in the bilateral canine regions and removable overdenture were prepared. The two implants and bilateral molar ridges were connected to three-axis load-cell transducers, and a universal testing machine was used to apply a 50 N vertical force to each site of the occlusal table in the first molar region. The denture movement was measured using a G(2) motion sensor. Three installation conditions, namely, the application of 0, 50, and 100 N loads were used to install each attachment on the denture base. The load transfer and denture movement were then evaluated. The resultant force decreased with increasing installation load for all attachments. In particular, the resultant force on implants on the loading side of the Locator attachment significantly decreased when the installation load was increased from 0 to 50 N, and that for magnetic attachment significantly decreased when the installation load was increased from 50 to 100 N. For the residual ridges on the loading side, the direction of the forces for all attachments changed to downward with increasing installation load. Furthermore, the yaw Euler angle increased with increasing installation load for the magnetic attachment. Subject to the limitations of this study, the use of any installation load greater than 0 N is recommended for the installation of ball and Locator attachments on a denture base. Regarding magnetic attachments, our results also recommend installation on a denture base using any installation load greater than 0 N, and suggest that the resultant force acting on the implant can be decreased by increasing the installation load; however, a large installation load of 100 N should be avoided when installing the attachment on the denture base to avoid increasing the denture movement. © 2014 by the American College of Prosthodontists.

  6. 2008 Federal Radionavigation Plan

    DOT National Transportation Integrated Search

    2009-01-01

    The Federal Radionavigation Plan (FRP) is the official source of radionavigation policy and planning for the Federal Government. The FRP covers common-use, Federally operated radionavigation systems. This edition of the FRP combines the Federal Radio...

  7. Dynamic response of RC beams strengthened with near surface mounted Carbon-FRP rods subjected to damage

    NASA Astrophysics Data System (ADS)

    Capozucca, R.; Blasi, M. G.; Corina, V.

    2015-07-01

    Near surface mounted (NSM) technique with fiber reinforced polymer (FRP) is becoming a common method in the strengthening of concrete beams. The availability of NSM FRP technique depends on many factors linked to materials and geometry - dimensions of the rods used, type of FRP material employed, rods’ surface configuration, groove size - and to adhesion between concrete and FRP rods. In this paper detection of damage is investigated measuring the natural frequency values of beam in the case of free-free ends. Damage was due both to reduction of adhesion between concrete and carbon-FRP rectangular and circular rods and cracking of concrete under static bending tests on beams. Comparison between experimental and theoretical frequency values evaluating frequency changes due to damage permits to monitor actual behaviour of RC beams strengthened by NSM CFRP rods.

  8. A state of the art review on reinforced concrete beams with openings retrofitted with FRP

    NASA Astrophysics Data System (ADS)

    Osman, Bashir H.; Wu, Erjun; Ji, Bohai; S Abdelgader, Abdeldime M.

    2016-09-01

    The use of externally bonded fiber reinforced polymer (FRP) sheets, strips or steel plates is a modern and convenient way for strengthening of reinforced concrete (RC) beams. Several researches have been carried out on reinforced concrete beams with web openings that strengthened using fiber reinforced polymer composite. Majority of researches focused on shear strengthening compared with flexural strengthening, while others studied the effect of openings on shear and flexural separately with various loading. This paper investigates the impact of more than sixty articles on opening reinforced concrete beams with and without strengthening by fiber reinforcement polymers FRP. Moreover, important practical issues, which are contributed in shear strengthening of beams with different strengthening techniques, such as steel plate and FRP laminate, and detailed with various design approaches are discussed. Furthermore, a simple technique of applying fiber reinforced polymer contributed with steel plate for strengthening the RC beams with openings under different load application is concluded. Directions for future research based on the existing gaps of the present works are presented.

  9. Using the Fire Weather Index (FWI) to improve the estimation of fire emissions from fire radiative power (FRP) observations

    NASA Astrophysics Data System (ADS)

    Di Giuseppe, Francesca; Rémy, Samuel; Pappenberger, Florian; Wetterhall, Fredrik

    2018-04-01

    The atmospheric composition analysis and forecast for the European Copernicus Atmosphere Monitoring Services (CAMS) relies on biomass-burning fire emission estimates from the Global Fire Assimilation System (GFAS). The GFAS is a global system and converts fire radiative power (FRP) observations from MODIS satellites into smoke constituents. Missing observations are filled in using persistence, whereby observed FRP values from the previous day are progressed in time until a new observation is recorded. One of the consequences of this assumption is an increase of fire duration, which in turn translates into an increase of emissions estimated from fires compared to what is available from observations. In this study persistence is replaced by modelled predictions using the Canadian Fire Weather Index (FWI), which describes how atmospheric conditions affect the vegetation moisture content and ultimately fire duration. The skill in predicting emissions from biomass burning is improved with the new technique, which indicates that using an FWI-based model to infer emissions from FRP is better than persistence when observations are not available.

  10. Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer.

    PubMed

    Koodaryan, Roodabeh; Hafezeqoran, Ali

    2016-12-01

    Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (α=.05). The bond strength values of A and S were significantly higher than those of N ( P <.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG ( P <.001). The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.

  11. 76 FR 63316 - Prospective Grant of Exclusive License: Secreted Frizzled Related Protein-1 (sFRP-1) and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-12

    ... Exclusive License: Secreted Frizzled Related Protein-1 (sFRP-1) and derivatives thereof and their Use In... belonging to the patent families having HHS Reference Numbers E-160-1997/0,/1,/2 and/3; E-014-2000/0; and E... Related Protein-1 (sFRP-1). sFRP-1, also known as SARP-2 (Secreted Apoptosis Related Protein-2). The IP...

  12. The Effect of Different Chemical Surface Treatments of Denture Teeth on Shear Bond Strength: A Comparative Study

    PubMed Central

    Palekar, Umesh; Awinashe, Vaibav; Mishra, Sunil Kumar; Kawadkar, Abhishek; Rahangdale, Tripti

    2014-01-01

    Background: The development of better cross linked acrylic resin teeth has solved the problems related to wearing and discoloration of acrylic teeth. The same cross linking at ridge lap region acts as a double edge sword as it weakens the bond between denture base and tooth. Aim of Study: The purpose of study was to evaluate the effect of surface treatment on the bond strength of resin teeth to denture base resin using monomethyl methacrylate monomer and dichloromethane with no surface treatment acting as control. Settings and Design:Denture base cylinder samples in wax (n=180) were made with maxillary central incisor attached at 450 (JIST 6506). These samples were randomly and equally divided into three groups of 60 each. These specimens were then flasked, dewaxed as per the standard protocol. Materials and Methods: Before acrylization, ridge lap area was treated as follows: Group A- no surface treatment act as control, Group B treated with monomethyl methacrylate monomer, Group C treated with dichloromethane. Digitally controlled acryliser was used for acrylization as per manufacturer’s instructions and shear bond strength was tested on Universal Testing Machine (Servo Hydraulic, 50kN High Strain, BISS Research). Statistical Analysis used: Result was statistically analyzed with One-way analysis of variance (ANOVA) and Post-hoc ANOVA Tukey’s HSD test at 5% level of significance. Results: The application of dichloromethane showed increased bond strength between cross linked acrylic resin teeth and heat cure denture base resin followed by monomethyl methacrylate monomer and control group. Conclusion: The application of dichloromethane on the ridge lap surface of the resin teeth before packing of the dough into the mold significantly increased the bond strength between cross linked acrylic resin teeth and heat cure denture base resin. PMID:25121057

  13. An Overview of the New FEER Smoke Emissions Product and Its Applications over Northern Sub-Saharan Africa

    NASA Astrophysics Data System (ADS)

    Ellison, L. T.; Ichoku, C. M.

    2012-12-01

    A new smoke emissions inventory is being derived by NASA's Fire Energetics and Emissions Research (FEER, http://feer.gsfc.nasa.gov/) group in conjunction with the NASA-funded interdisciplinary research project on the interactions and feedbacks between biomass burning and water cycle dynamics across the Northern Sub-Saharan African (NSSA) region. The vast amount of anthropogenic biomass burning conducted in NSSA during the dry months contributes significant amounts of gaseous and particulate emissions to the local climate system. The emissions product presented here is a result of the efforts made to utilize quantitative satellite measures of important fire and smoke variables to generate an accurate emissions product that can be used to quantify the relationship between biomass burning and regional climate impacts. This new product is based on a unique top-down approach whereby radiant energy and emission rates are related from independent yet coincident remotely sensed retrievals of fire radiative power (FRP) and aerosol optical depth (AOD) from the two active Moderate Resolution Imaging Spectroradiometer (MODIS) instruments. The algorithm produces a 1×1° global grid of coefficients of emission, Ce, that directly relate FRP to emission rates, or equivalently, fire radiative energy (FRE, the temporally integrated FRP curve) to emissions. Thus, emissions can be easily and quickly obtained in a given region by multiplying the Ce grid with FRP measurements acquired within that region. The Ce product offers the user flexibility in using any desired FRP data source, and the lag time in generating emissions is only constrained by that of obtaining FRP. The accuracy of this emissions product and its comparisons to other established emissions databases are presented here, as is a discussion of the contribution that this product will make toward accounting for climate variabilities in the NSSA region.

  14. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    PubMed

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  15. Oral mucosal lesions in denture wearers.

    PubMed

    Jainkittivong, Aree; Aneksuk, Vilaiwan; Langlais, Robert P

    2010-03-01

    To determine the prevalence of oral mucosal lesions (OMLs) and denture-related mucosal lesions (DMLs) in denture wearers and to co-relate the prevalence with age, gender, type of denture and any systemic conditions. Dental records of 380 denture wearers were retrospectively reviewed for OMLs and DMLs. We found 45% of the denture wearers had DMLs and 60.8% had OMLs not related to denture wearing. Although the prevalence of DMLs was higher in complete denture wearers than in partial denture wearers (49% vs. 42.2%), this difference was not significant. The most common DMLs were traumatic ulcer (19.5%) and denture-induced stomatitis (18.1%). When analysed by type, traumatic ulcer, denture hyperplasia, frictional keratosis and candidiasis were more common in complete denture wearers, whereas denture-induced stomatitis was more common in partial denture wearers. Frictional keratosis was more common in men than in women. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers, and the most common OML was fissured tongue (27.6%). No association between DMLs and systemic conditions or xerostomic drugs was noted. No differences in the prevalence of DMLs in association with denture type were found. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers. This difference was affected by age, and the data were similar to the findings observed in the elderly.

  16. Dynamic strain distribution of FRP plate under blast loading

    NASA Astrophysics Data System (ADS)

    Saburi, T.; Yoshida, M.; Kubota, S.

    2017-02-01

    The dynamic strain distribution of a fiber re-enforced plastic (FRP) plate under blast loading was investigated using a Digital Image Correlation (DIC) image analysis method. The testing FRP plates were mounted in parallel to each other on a steel frame. 50 g of composition C4 explosive was used as a blast loading source and set in the center of the FRP plates. The dynamic behavior of the FRP plate under blast loading were observed by two high-speed video cameras. The set of two high-speed video image sequences were used to analyze the FRP three-dimensional strain distribution by means of DIC method. A point strain profile extracted from the analyzed strain distribution data was compared with a directly observed strain profile using a strain gauge and it was shown that the strain profile under the blast loading by DIC method is quantitatively accurate.

  17. Optic fiber sensor-based smart bridge cable with functionality of self-sensing

    NASA Astrophysics Data System (ADS)

    He, Jianping; Zhou, Zhi; Jinping, Ou

    2013-02-01

    Bridge cables, characterized by distributed large span, serving in harsh environment and vulnerability to random damage, are the key load-sustaining components of cable-based bridges. To ensure the safety of the bridge structure, it is critical to monitor the loading conditions of these cables under lengthwise random damages. Aiming at obtaining accurate monitoring at the critical points as well as the general information of the cable force distributed along the entire cable, this paper presents a study on cable force monitoring by combining optical fiber Bragg grating (FBG) sensors and Brillouin optical time domain analysis/reflectory (BOTDA/R) sensing technique in one single optical fiber. A smart FRP-OF-FBG rebar based cable was fabricated by protruding a FRP packaged OF-FBG sensor into the bridge cable. And its sensing characteristics, stability under high stress state temperature self-compensation as well as BOTDA/R distributed data improvement by local FBG sensors have been investigated. The results show that FRP-OF-FBG rebar in the smart cable can deform consistantly along with the steel wire and the cable force obtained from the optical fiber sensors agree well with theoretical value with relative error less than ±5%. Besides, the temperature self-compensation method provides a significant cost-effective technique for the FRP-OF-FBG based cables' in situ cable force measurement. And furthermore, potential damages of the bridge cable, e.g. wire breaking and corrosion, can be characterized and symbolized by the discontinuity and fluctuation of the distributed BOTDA data thereafter accuracy improved by local FBG sensors.

  18. Using JPSS VIIRS Fire Radiative Power Data to Forecast Biomass Burning Emissions and Smoke Transport by the High Resolution Rapid Refresh Model

    NASA Astrophysics Data System (ADS)

    Ahmadov, R.; Grell, G. A.; James, E.; Alexander, C.; Stewart, J.; Benjamin, S.; McKeen, S. A.; Csiszar, I. A.; Tsidulko, M.; Pierce, R. B.; Pereira, G.; Freitas, S. R.; Goldberg, M.

    2017-12-01

    We present a new real-time smoke modeling system, the High Resolution Rapid Refresh coupled with smoke (HRRR-Smoke), to simulate biomass burning (BB) emissions, plume rise and smoke transport in real time. The HRRR is the NOAA Earth System Research Laboratory's 3km grid spacing version of the Weather Research and Forecasting (WRF) model used for weather forecasting. Here we make use of WRF-Chem (the WRF model coupled with chemistry) and simulate fine particulate matter (smoke) emissions emitted by BB. The HRRR-Smoke modeling system ingests fire radiative power (FRP) data from the Visible Infrared Imaging Radiometer Suite (VIIRS) sensor on the Suomi National Polar-orbiting Partnership (S-NPP) satellite to calculate BB emissions. The FRP product is based on processing 750m resolution "M" bands. The algorithms for fire detection and FRP retrieval are consistent with those used to generate the MODIS fire detection data. For the purpose of ingesting VIIRS fire data into the HRRR-Smoke model, text files are generated to provide the location and detection confidence of fire pixels, as well as FRP. The VIIRS FRP data from the text files are processed and remapped over the HRRR-Smoke model domains. We process the FRP data to calculate BB emissions (smoldering part) and fire size for the model input. In addition, HRRR-Smoke uses the FRP data to simulate the injection height for the flaming emissions using concurrently simulated meteorological fields by the model. Currently, there are two 3km resolution domains covering the contiguous US and Alaska which are used to simulate smoke in real time. In our presentation, we focus on the CONUS domain. HRRR-Smoke is initialized 4 times per day to forecast smoke concentrations for the next 36 hours. The VIIRS FRP data, as well as near-surface and vertically integrated smoke mass concentrations are visualized for every forecast hour. These plots are provided to the public via the HRRR-Smoke web-page: https://rapidrefresh.noaa.gov/HRRRsmoke/. Model evaluations for a case study are presented, where simulated smoke concentrations are compared with hourly PM2.5 measurements from EPA's Air Quality System network. These comparisons demonstrate the model's ability in simulating high aerosol loadings during major wildfire events in the western US.

  19. Factors affecting the distribution and prevalence of oral mucosal lesions in complete denture wearers.

    PubMed

    Mandali, Gamze; Sener, Işıl Damla; Turker, Sebnem Begum; Ulgen, Hasan

    2011-06-01

    To determine the frequency of the oral lesions related to gender, age, the length of time of denture usage, education level and economic status. The 153 patients with old complete dentures (CD) were asked to participate in the investigation. The subjects (76 male and 77 female) were 37-85 years of age with a mean age of 61.8 ± 9.8 years. Education, economic status and age factors were estimated in subgroups. The data obtained were evaluated by one-way anova, Mann-Whitney U-test, Kruskal-Wallis test, Student's t-test and chi-squared test. The level of statistical significance was set at p<0.05. The patients who had denture stomatitis and traumatic ulcers were statistically significantly older than the ones who did not have these lesions (p<0.05). Based on the length of denture usage, patients who had a flabby ridge, fibrous inflammatory hyperplasia, traumatic ulcers (p<0.01) and denture stomatitis (p<0.05) were using their dentures statistically significantly longer than the ones who had healthy tissues. The CD wearers should be advised to visit their dentist regularly to prevent oral mucosal lesions due to the changing supporting tissues during the length of denture usage and to improve their quality of life. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  20. Influence of different base thicknesses on maxillary complete denture processing: linear and angular graphic analysis on the movement of artificial teeth.

    PubMed

    Mazaro, José Vitor Quinelli; Gennari Filho, Humberto; Vedovatto, Eduardo; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza; Zavanelli, Adriana Cristina

    2011-09-01

    The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization. A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc). Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric. All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.

  1. Design and construction guidelines for strengthening bridges using fiber reinforced polymers (FRP).

    DOT National Transportation Integrated Search

    2014-09-01

    This research concerns the development of guidelines : for the design and use of externally-bonded FRP : strengthening systems on bridges in Michigan. Si : x representative international FRP-related guidelines : were analyzed and compared for applica...

  2. Study on effects of different patterns and cracking for wastes FRP (used banner) wrapping on compressive strength of confined concrete

    NASA Astrophysics Data System (ADS)

    Syazani Leman, Alif; Shahidan, Shahiron; Azmi, M. A. M.; Syamir Senin, Mohamad; Ali, N.; Abdullah, S. R.; Zuki, S. S. Mohd; Ibrahim, M. H. Wan; Nazri, Fadzli Mohamed

    2017-11-01

    Previous researches have shown that FRP are being introduce into wide variety of civil engineering applications. Fibre Reinforce Concrete (FRP) are also used as repairing method in concrete structures. FRP such as S-glass, AR-glass, E-glass, C-glass, and Aramid Fibre are the common material used in industry. The FRP strips provide the necessary longitudinal and hoop reinforcement. However, there are lots waste materials that can be form as fibre and used in repairing. Banner is a type of waste material fibre that can be used in repairing. In this study, banner will be used as the replacement of the common FRP. The confined concrete (cylinder) of 300mm height and 150mm diameter were cast with M35 grade concrete and tested until it is crack. Next banner are used as the wrapping along the cracking of the concrete with three different pattern that are full wrapping, two band wrapping and cross wrapping using epoxy. Epoxy is a common name for a type of strong adhesive used for sticking things together and covering surface. The objective of this study is to determine the maximum strength and the effect of different patterns wrapping of FRP (banner) on the compressive strength of confined concrete. The results are shows that banner are suitable as a replacement of material for FRP.

  3. FRP : Strengthened RC Structures

    NASA Astrophysics Data System (ADS)

    Teng, J. G.; Chen, J. F.; Smith, S. T.; Lam, L.

    2002-01-01

    The strengthening of reinforced concrete (RC) structures using advanced fibre-reinforced polymer (FRP) composites, and in particular the behaviour of FRP-strengthened RC structures is a topic which has become very popular in recent years. This popularity has arisen due to the need to maintain and upgrade essential infrastructure in all parts of the world, combined with the well-known advantages of FRP composites, such as good corrosion resistance and ease for site handling due to their light weight. The continuous reduction in the material cost of FRP composites has also contributed to their popularity. While a great amount of research now exists in the published literature on this topic, it is scattered in various journals and conference proceedings. This book therefore provides the first ever comprehensive, state-of-the-art summary of the existing research on FRP strengthening of RC structures, with the emphasis being on structural behaviour and strength models. The main topics covered include: Bond behaviour Flexural and shear strengthening of beams Column strengthening Flexural strengthening of slabs. For each area, the methods of strengthening are discussed, followed by a description of behaviour and failure modes and then the presentation of rational design recommendations, for direct use in practical design of FRP strengthening measures. Researchers, practicing engineers, code writers and postgraduate students in structural engineering and construction materials, as well as consulting firms, government departments, professional bodies, contracting firms and FRP material suppliers will find this an invaluable resource.

  4. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    PubMed

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  5. The development of crashworthy rails for fiber reinforced polymer honeycomb bridge deck system.

    DOT National Transportation Integrated Search

    2015-07-01

    Fiber reinforced polymer (FRP) honeycomb panels offer an efficient and rapid replacement to : concrete decks. The system consists of FRP honeycomb sandwich panels with adequate guardrails. Although : FRP bridge deck panels have already been designed ...

  6. The development of crashworthy rails for fiber reinforced polymer honeycomb bridge deck system : [summary].

    DOT National Transportation Integrated Search

    2015-07-01

    Fiber reinforced polymer (FRP) honeycomb panels offer an efficient and rapid : replacement to concrete decks. The system consists of FRP honeycomb sandwich panels : with adequate guardrails. Although FRP bridge deck panels have already been designed ...

  7. Polyurethane foam infill for fiber-reinforced polymer (FRP) bridge deck panels.

    DOT National Transportation Integrated Search

    2014-05-01

    Although still in their infancy, fiber-reinforced polymer (FRP) bridges have shown great promise in eliminating corrosion : concerns and meeting (or exceeding) FHWAs goal of 100-year life spans for bridges. While FRP bridges are cost-effective in ...

  8. Resilient Attachments as an Alternative to Conventional Cast Clasp Removable Partial Denture: 3-Year Follow-up.

    PubMed

    Schuh, Cristian; Adiel Skupien, Jovito; Mesko, Mauro Elias; Valentini, Fernanda; Pereira-Cenci, Tatiana; Boscato, Noéli

    2014-12-01

    The present clinical report describes the prosthodontic management for a patient with uncontrolled bleeding and diabetes mellitus treated with a maxillary complete denture and a mandibular partial fixed dental prosthesis designed to interface with a removable cast framework partial denture retained by 2 ERA attachments. This approach was undertaken to improve both retention and stability of the distal extension Kennedy Class I removable partial denture. The rehabilitation provided better anterior esthetics than if treated with a conventional clasp retained removable partial denture, by employing a simple, practical design and offering a significant biomechanical advantages, restoring both oral health and function. Thus, this treatment modality, involving an ERA system and transfixation in fixed crowns, is an effective treatment and can be indicated as a clinical alternative for edentulous and partially edentulous patients with systemic disorders or for patients in economic situations that might preclude implant-based rehabilitation.

  9. The effectiveness of adhesives on the retention of mandibular free end saddle partial dentures: An in vitro study.

    PubMed

    Quiney, Daniel; Nishio Ayre, Wayne; Milward, Paul

    2017-07-01

    Existing in vitro methods for testing denture adhesives do not fully replicate the complex oral geometries and environment; and in vivo methods are qualitative, prone to bias and not easily reproducible. The purpose of this study was to develop a novel, quantitative and more accurate model to test the effect of adhesives on the retentive force of mandibular free end saddle partial dentures. An in vitro model was developed based on an anatomically accurate cast of a clinical case. Experimentally, the amount of adhesive was varied (0.2g-1g) and the tensile force required for displacement was measured. Different commercially available adhesives were then tested at the optimum volume using the in vitro model. A 3D finite element model of the denture was used to assess how the forces to induce denture displacement varied according to the position of the force along the saddle length. The mass of adhesive was found to significantly alter retention forces, with 0.4-0.7g being the optimum range for this particular scenario. Use of adhesives significantly improved mandibular free end saddle partial denture retention with the worst performing adhesive increasing retention nine-fold whilst the best performing adhesive increased retention twenty three-fold. The finite element model revealed that 77% more force was required to displace the denture by positioning forces towards the mesial end of the saddle compared to the distal end. An in vitro denture adhesive model was developed, which demonstrated that mass of adhesive plays a significant role in enhancing denture retention and supported the design principle of placing as few teeth as clinically necessary on the distal end of the free end saddles. Limiting the position of teeth on free end saddles to the mesial and mid portion of the saddle will reduce displacements caused by mastication. The movement of mandibular free end saddle partial dentures can be restricted with the use of denture adhesives. Altering the mass of adhesive used can further improve the retention of mandibular free end saddle partial dentures for patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Effect of polymerization technique and glass fiber addition on the surface roughness and hardness of PMMA denture base material.

    PubMed

    Gad, Mohammed M; Rahoma, Ahmed; Al-Thobity, Ahmad M

    2018-06-20

    The current study evaluated the effects of autoclave polymerization both with and without glass fiber (GF) reinforcement on the surface roughness and hardness of acrylic denture base material. Ninety disc specimens (30×2.5 mm) were prepared from Vertex resin and divided according to polymerization techniques into a water bath, short and long autoclave polymerization groups. Tested groups were divided into three subgroups according to the GF concentration (0, 2.5, and 5 wt%). Profilometer and Vickers hardness tests were performed to measure surface roughness and hardness. ANOVA and Tukey-Kramer multiple comparison tests analyzed the results, and p≤0.05 was considered statistically significant. Autoclave polymerization significantly decreased the surface roughness and increased the hardness of acrylic resin without GF reinforcement (p<0.05). However, 5 wt% GF addition significantly increased surface roughness and decreased hardness of the autoclave polymerized denture base resin (p<0.05). Surface properties of Polymethyl methacrylate (PMMA) denture base material improved with autoclave polymerization and negatively affected with GFs addition.

  11. [Principles of bone tissue structures interaction with full removable dentures fixed on intraosseous implantates modelling].

    PubMed

    Shashmurina, V R; Chumachenko, E N; Olesova, V N; Volozhin, A I

    2008-01-01

    Math modelling "removable dentures-implantate-bone" with size and density of bone tissue as variables was created. It allowed to study biomechanical bases of mandibular bone tissue structures interaction with full removable dentures of different constructions and fixed on intraosseous implantates. Analysis of the received data showed that in the majority of cases it was expedient to recommend 3 bearing (abutments) system of denture making. Rest on 4 and more implantates was appropriate for patients with reduced density of spongy bone and significant mandibular bone atrophy. 2 abutment system can be used in patients with high density of spongy bone and absence of mandibular bone atrophy.

  12. Treatment of edentulism: optimizing outcomes with tissue management and impression techniques.

    PubMed

    Salinas, Thomas J

    2009-02-01

    Significant numbers of patients throughout the world seek treatment for edentulism. The trend toward tissue-integrated prostheses has been a monumental step in restoring edentulous patients to function; however, this treatment can be out of reach for those who fail to qualify or those who do not have sufficient resources to afford it. In these cases, conventional dentures remain an important primary course of treatment. Attention to detail when diagnosing, treatment planning, and performing treatment for these patients is still a prime consideration for the best possible outcome. In particular, many experienced denture wearers are afflicted with chronically inflamed denture-bearing mucosa. Clinicians must recognize the need for tissue conditioning, choices of impression materials, and accepted fabrication techniques that can have favorable outcomes when matched with patients who are philosophical and realistic in their expectations. The purpose of this article is to review impression philosophies, associated materials, and methods of tissue conditioning. Retention and stability of the denture bases can be augmented by the routine use of denture adhesive, and indications for use of denture adhesive will be discussed.

  13. Repair & Strengthening of Distressed/Damaged Ends of Prestressed Beams with FRP Composites

    DOT National Transportation Integrated Search

    2018-02-01

    Over the past few decades, fiber reinforced polymer (FRP) composites have emerged as a lightweight and efficient material used for the repair and retrofit of concrete infrastructures. FRP can be applied to concrete as either externally bonded laminat...

  14. Highly accelerated lifetime for externally applied bond critical fiber-reinforced polymer (FRP) infrastructure materials : [summary].

    DOT National Transportation Integrated Search

    2014-03-01

    The Florida Department of Transportation (FDOT) uses fiber-reinforced polymer (FRP) composites to repair bridges and strengthen bridge decks. Proven mechanical characteristics make FRP composites cost-effective in extending the life span of bridges o...

  15. Repairing/strengthening of bridges with post-tensioned FRP strands and performance evaluation.

    DOT National Transportation Integrated Search

    2008-06-01

    The proposed project is to take advantage of some new developments in bridge engineering to apply fiber reinforced polymers (FRP) post-tensioning strands on a selected structure. The use of externally post-tensioned FRP strands to repair/strengthen b...

  16. Splicing and local reinforcement of concrete filled FRP tubes.

    DOT National Transportation Integrated Search

    2014-01-01

    This report includes fulfillment of Task 1 of a multi-task contract to further enhance concrete filled FRP tubes, or : the Bridge in a Backpack. Task 1 investigates and develops a feasible solution for splicing the concrete filled FRP : tubes. This w...

  17. Denture-induced fibrous inflammatory hyperplasia: a retrospective study in a school of dentistry.

    PubMed

    Coelho, C M; Zucoloto, S; Lopes, R A

    2000-01-01

    The aim of this study was to investigate the denture-induced fibrous inflammatory hyperplasia (FIH) that occurs around the borders of an ill-fitting denture, in relation to frequency of the lesion, age and sex distribution, length of denture use, and frequency of dysplasia. A comprehensive review of FIH diagnosed in patients wearing dentures by the oral pathology diagnostic service at the University of São Paulo over 26 years (1971 to 1996) was undertaken, based on retrospective analysis of the oral histopathologic files. The frequency of FIH was 15% of the total number of pathologies diagnosed at the service of oral pathology in that period. The disorder occurred predominantly in the fifth and sixth decades of life and more often among females, at a proportion of 5:1. The frequency of FIH was higher for a length of denture use of between 1 and 10 years. Dysplasia was found in 4% of cases. The knowledge of some aspects of FIH, especially the possible histologic alteration of dysplasia, supports the importance of the diagnosis and treatment of the lesion and suggests that any excised tissue should be submitted to histopathologic evaluation. Education and regular review of patients who have worn dentures are essential if the development of FIH is to be prevented.

  18. Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique.

    PubMed

    Ye, Ye; Jiao, Ting; Zhu, Jiarui; Sun, Jian

    2018-01-24

    The purpose of the study was to evaluate the adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by the selective laser melting (SLM) technique. Twenty pairs of edentulous casts were randomly and evenly divided into two groups, and manufacturing of the Co-Cr alloy maxillary complete denture base was conducted either by the SLM technique or by the conventional method. The base-cast sets were transversally sectioned into three sections at the distal canines, mesial of the first molars and the posterior palatal zone. The gap between the metal base and cast was measured in these three sections with a stereoscopic microscope, and the data were analysed using t tests. A total of five specimens of 5 mm diameter were fabricated with the Co-Cr alloy by SLM and the traditional casting technology. A scanning electron microscope (SEM) was used to evaluate the differences in microstructure between these specimens. There was no statistical difference between the three sections in all four groups (P > 0.05). At the region of the canines, the clearance value for the SLM Co-Cr alloy group was larger than that of the conventional method group (P < 0.05). At the mesial of the first molar region and the posterior palatal zone, there was no statistical difference between the gaps observed in the two groups (P > 0.05). The SLM Co-Cr alloy has a denser microstructure behaviour and less casting defect than the cast Co-Cr alloy. The SLM technique showed initial feasibility for the manufacture of dental bases of complete dentures, but large sample studies are needed to prove its reliability in clinical applications. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures are appropriate for clinical use.

  19. Effect of the tapered end of a FRP plate on the interfacial stresses in a strengthened beam used in civil engineering applications

    NASA Astrophysics Data System (ADS)

    Mahi, B. E.; Benrahou, K. H.; Belakhdar, Kh.; Tounsi, A.; Bedia, E. A. Adda

    2014-09-01

    The interfacial stresses of a beam strengthened with a FRP plate, which is widely employed in the civil engineering for rehabilitation and retrofitting of conventional structures, is investigated. An important feature of the reinforced beam is significant stress concentrations in the adhesive at the ends of the FRP plate. To reduce these interfacial stresses, a FRP plate with a tapered end is often used. The finite-difference method is utilized in this work to predict the distribution of interfacial stresses in beams strengthened with a FRP plate having a tapered end. Numerical results from the analysis are presented to demonstrate the advantages of using tapers in the design of strengthened beams.

  20. Can plant-based natural flax replace mineral-based basalt and synthetic E-glass for fibre reinforced polymer tubular energy absorbers? A comparative study on quasi-static axial crushing

    NASA Astrophysics Data System (ADS)

    Yan, Libo; Wang, Bo; Kasal, Bohumil

    2017-12-01

    Using plant-based natural fibres to substitute glass fibres as reinforcement of composite materials is of particular interest due to their economic, technical and environmental significance. One potential application of plant-based natural fibre reinforced polymer (FRP) composites is in automotive engineering as crushable energy absorbers. Current study experimentally investigated and compared the energy absorption efficiency of plant-based natural flax, mineral-based basalt and glass FRP composite tubular energy absorbers subjected to quasi-static axial crushing. The effects of number of flax fabric layer, the use of foam-filler and the type of fibre materials on the crashworthiness characteristics and energy absorption capacities were discussed. In addition, the failure mechanisms of the hollow and foam-filled flax, basalt and glass FRP tubes in quasi-static axial crushing were analysed and compared. The test results showed that the energy absorption capabilities of both hollow and foam-filled energy absorbers made of flax were superior to the corresponding energy absorbers made of basalt and were close to energy absorbers made of glass. This study therefore indicated that flax fibre has the great potential to be suitable replacement of basalt and glass fibres for crushable energy absorber application.

  1. Elimination of deck joints using a corrosion resistant FRP approach : LTRC technical summary report 443.

    DOT National Transportation Integrated Search

    2009-01-01

    In the literature survey of fiber reinforced polymer (FRP) grid reinforced concrete : structures, a limited number of studies were found on FRP grid stiffened concrete slabs : in bridge deck applications and other non-structural applications in build...

  2. Development of advanced grid stiffened (AGS) fiber reinforced polymer (FRP) tube-encased concrete columns.

    DOT National Transportation Integrated Search

    2013-03-01

    In this project, a new type of confining device, a latticework of interlacing fiber reinforced polymer (FRP) ribs that are jacketed by a FRP skin, is proposed, manufactured, tested, and modeled to encase concrete cylinders. This systematic study incl...

  3. FRP/steel composite damage acoustic emission monitoring and analysis

    NASA Astrophysics Data System (ADS)

    Li, Dongsheng; Chen, Zhi

    2015-04-01

    FRP is a new material with good mechanical properties, such as high strength of extension, low density, good corrosion resistance and anti-fatigue. FRP and steel composite has gotten a wide range of applications in civil engineering because of its good performance. As the FRP/steel composite get more and more widely used, the monitor of its damage is also getting more important. To monitor this composite, acoustic emission (AE) is a good choice. In this study, we prepare four identical specimens to conduct our test. During the testing process, the AE character parameters and mechanics properties were obtained. Damaged properties of FRP/steel composite were analyzed through acoustic emission (AE) signals. By the growing trend of AE accumulated energy, the severity of the damage made on FRP/steel composite was estimated. The AE sentry function has been successfully used to study damage progression and fracture emerge release rate of composite laminates. This technique combines the cumulative AE energy with strain energy of the material rather than analyzes the AE information and mechanical separately.

  4. Design equations for the assessment and FRP-strengthening of reinforced rectangular concrete columns under combined biaxial bending and axial loads

    NASA Astrophysics Data System (ADS)

    Alessandri, S.; Monti, G.

    2008-05-01

    A simple procedure is proposed for the assessment of reinforced rectangular concrete columns under combined biaxial bending and axial loads and for the design of a correct amount of FRP-strengthening for underdesigned concrete sections. Approximate closed-form equations are developed based on the load contour method originally proposed by Bresler for reinforced concrete sections. The 3D failure surface is approximated along its contours, at a constant axial load, by means of equations given as the sum of the acting/resisting moment ratio in the directions of principal axes of the sections, raised to a power depending on the axial load, the steel reinforcement ratio, and the section shape. The method is extended to FRP-strengthened sections. Moreover, to make it possible to apply the load contour method in a more practical way, simple closed-form equations are developed for rectangular reinforced concrete sections with a two-way steel reinforcement and FRP strengthenings on each side. A comparison between the approach proposed and the fiber method (which is considered exact) shows that the simplified equations correctly represent the section interaction diagram.

  5. Performance range of SMA actuator wires and SMA-FRP structure in terms of manufacturing, modeling and actuation

    NASA Astrophysics Data System (ADS)

    Hübler, M.; Gurka, M.; Schmeer, S.; Breuer, U. P.

    2013-09-01

    In this contribution we present a comprehensive theoretical and experimental description of an active shape memory alloy (SMA) fiber reinforced composite (FRP) hybrid structure. The major influences on actuation performance arising from variations in the design and manufacturing process are discussed, utilizing a new phenomenological model to describe the actuating SMA material. The different material properties for the activated, respective the unactivated, SMA as well as the influence of different loading conditions or pre-treatment of the material are taken into account in this model. To validate our material model we performed new actuation experiments with an exemplary SMA-FRP structure, which we compared to finite element (FE) simulation results. Our FE-model is based on a material model for the actuating SMA elements derived from experiments and data on the actual microscopic geometry of the hybrid composite. Therefore it is able to predict very precisely the actuation behavior of a typical FRP structure for industrial use cases: a thin walled CFRP sheet with SMA wires attached to the top for performing a bending motion with a maximum deflection of approx. 25% of its length.

  6. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis

    PubMed Central

    Nawasrah, Amal; AlNimr, Amani; Ali, Aiman A.

    2016-01-01

    Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufacturer instruction for processing complete dentures. The other five groups were processed by adding different concentration of Yamani henna powder (Harazi) to the polymer in a concentration of henna: polymer 1%, 2.5%, 5%, 7.5% and 10%, respectively. Samples were incubated in artificial saliva rich with Candida albicans at 37 °C, and the effect of henna on Candida albicans was evaluated in two different methods: semi-quantitative slide count and a culture-based quantitative assay (quantitative). Variation in the number of live Candida was observed with the increase in the concentration of Yamani henna powder. It was observed that the variation in live Candida, between control group and group B (concentration of Yamani henna powder was 1%), was statistically significant with a p-value of 0.0001. Similarly, variations in live Candida were significant, when the concentration of powder was 7.5% or 10% in contrast with control group and p-values were 0.0001 and 0.001 respectively. Adding henna to acrylic resin denture could be effective in controlling Candida albicans proliferation on the denture surface; however, its effects on the physical properties of acrylic resin denture need further studies. PMID:27223294

  7. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

    PubMed

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  8. LSA SAF Meteosat FRP products - Part 1: Algorithms, product contents, and analysis

    NASA Astrophysics Data System (ADS)

    Wooster, M. J.; Roberts, G.; Freeborn, P. H.; Xu, W.; Govaerts, Y.; Beeby, R.; He, J.; Lattanzio, A.; Fisher, D.; Mullen, R.

    2015-11-01

    Characterizing changes in landscape fire activity at better than hourly temporal resolution is achievable using thermal observations of actively burning fires made from geostationary Earth Observation (EO) satellites. Over the last decade or more, a series of research and/or operational "active fire" products have been developed from geostationary EO data, often with the aim of supporting biomass burning fuel consumption and trace gas and aerosol emission calculations. Such Fire Radiative Power (FRP) products are generated operationally from Meteosat by the Land Surface Analysis Satellite Applications Facility (LSA SAF) and are available freely every 15 min in both near-real-time and archived form. These products map the location of actively burning fires and characterize their rates of thermal radiative energy release (FRP), which is believed proportional to rates of biomass consumption and smoke emission. The FRP-PIXEL product contains the full spatio-temporal resolution FRP data set derivable from the SEVIRI (Spinning Enhanced Visible and Infrared Imager) imager onboard Meteosat at a 3 km spatial sampling distance (decreasing away from the west African sub-satellite point), whilst the FRP-GRID product is an hourly summary at 5° grid resolution that includes simple bias adjustments for meteorological cloud cover and regional underestimation of FRP caused primarily by underdetection of low FRP fires. Here we describe the enhanced geostationary Fire Thermal Anomaly (FTA) detection algorithm used to deliver these products and detail the methods used to generate the atmospherically corrected FRP and per-pixel uncertainty metrics. Using SEVIRI scene simulations and real SEVIRI data, including from a period of Meteosat-8 "special operations", we describe certain sensor and data pre-processing characteristics that influence SEVIRI's active fire detection and FRP measurement capability, and use these to specify parameters in the FTA algorithm and to make recommendations for the forthcoming Meteosat Third Generation operations in relation to active fire measures. We show that the current SEVIRI FTA algorithm is able to discriminate actively burning fires covering down to 10-4 of a pixel and that it appears more sensitive to fire than other algorithms used to generate many widely exploited active fire products. Finally, we briefly illustrate the information contained within the current Meteosat FRP-PIXEL and FRP-GRID products, providing example analyses for both individual fires and multi-year regional-scale fire activity; the companion paper (Roberts et al., 2015) provides a full product performance evaluation and a demonstration of product use within components of the Copernicus Atmosphere Monitoring Service (CAMS).

  9. Incorporation of antimicrobial macromolecules in acrylic denture base resins: a research composition and update.

    PubMed

    Sivakumar, Indumathi; Arunachalam, Kuthalingam Subbiah; Sajjan, Suresh; Ramaraju, Alluri Venkata; Rao, Bheemalingeshwara; Kamaraj, Bindu

    2014-06-01

    Contemporary research in acrylic denture base materials focuses on the development of a novel poly(methyl methacrylate) (PMMA) resin with antimicrobial properties. Although PMMA resin has fulfilled all the requirements of an ideal denture base material, its susceptibility to microbial colonization in the oral environment is a formidable concern to clinicians. Many mechanisms including the absence of ionic charge in the methyl methacrylate resins, hydrophobic interactions, electrostatic interactions, and mechanical attachment have been found to contribute to the formation of biofilm. The present article outlines the basic categories of potential antimicrobial polymer (polymeric biocides) formulations (modified PMMA resins) and considers their applicability, biological status, and usage potential over the coming years. © 2013 by the American College of Prosthodontists.

  10. Do flexible acrylic resin lingual flanges improve retention of mandibular complete dentures?

    PubMed Central

    Ahmed Elmorsy, Ayman Elmorsy; Ahmed Ibraheem, Eman Mostafa; Ela, Alaa Aboul; Fahmy, Ahmed; Nassani, Mohammad Zakaria

    2015-01-01

    Objectives: The aim of this study was to compare the retention of conventional mandibular complete dentures with that of mandibular complete dentures having lingual flanges constructed with flexible acrylic resin “Versacryl.” Materials and Methods: The study sample comprised 10 completely edentulous patients. Each patient received one maxillary complete denture and two mandibular complete dentures. One mandibular denture was made of conventional heat-cured acrylic resin and the other had its lingual flanges made of flexible acrylic resin Versacryl. Digital force-meter was used to measure retention of mandibular dentures at delivery and at 2 weeks and 45 days following denture insertion. Results: The statistical analysis showed that at baseline and follow-up appointments, retention of mandibular complete dentures with flexible lingual flanges was significantly greater than retention of conventional mandibular dentures (P < 0.05). In both types of mandibular dentures, retention of dentures increased significantly over the follow-up period (P < 0.05). Conclusions: The use of flexible acrylic resin lingual flanges in the construction of mandibular complete dentures improved denture retention. PMID:26539387

  11. IN VITRO WEAR RESISTANCE OF THREE TYPES OF POLYMETHYL METHACRYLATE DENTURE TEETH

    PubMed Central

    Reis, Katia Rodrigues; Bonfante, Gerson; Pegoraro, Luiz Fernando; Conti, Paulo Cesar Rodrigues; de Oliveira, Pedro Cesar Garcia; Kaizer, Osvaldo Bazzan

    2008-01-01

    The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (α=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth. PMID:19089214

  12. Hybrid FRP-concrete bridge deck system final report II : long term performance of hybrid FRP-concrete bridge deck system.

    DOT National Transportation Integrated Search

    2009-06-01

    This report describes the investigation of the long term structural performance of a : hybrid FRP-concrete (HFRPC) bridge deck on steel girders. The study aimed at : assessing three long term aspects pertaining to the HFRPC bridge deck: (1) creep : c...

  13. Fiber reinforced polymer (FRP) composite piles used on pier rehabilitation, Little Diamond Island, Casco Bay, Portland, Maine.

    DOT National Transportation Integrated Search

    2012-10-01

    Fiber reinforced polymer (FRP) composite piles were used on a pier rehabilitation project at : Little Diamond Island in Casco Bay near Portland Maine. The project was the replacement : of an aging wooden pier at the ferry berthing terminal. The FRP p...

  14. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles : Task 5 : laminate durability testing : final report.

    DOT National Transportation Integrated Search

    2015-05-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 5, Laminate Durability Testing. : Mechanical properties of the FRP mat...

  15. Development of advanced grid stiffened (AGS) fiber reinforced polymer (FRP) tube-encased concrete columns : [technical summary].

    DOT National Transportation Integrated Search

    2013-03-01

    In recent years, the use of fi ber reinforced polymer (FRP) tube-encased concrete columns for new construction and rebuilding : of engineering structures has increased. The purpose in FRP tube-encased concrete columns is to replace the steel rebar by...

  16. Deformation Analysis of RC Ties Externally Strengthened with FRP Sheets

    NASA Astrophysics Data System (ADS)

    Gribniak, V.; Arnautov, A. K.; Kaklauskas, G.; Jakstaite, R.; Tamulenas, V.; Gudonis, E.

    2014-11-01

    The current study has two objectives: to validate the ability of the Atena finite-element software to estimate the deformations of reinforced concrete (RC) elements strengthened with fiber-reinforced polymer (FRP) sheets and to assess the effect of FRP-to-concrete bond strength on the results of numerical simulation. It is shown that the bond strength has to be selected according to the overall stiffness of the composite element. The numerical results found are corroborated experimentally by tensile tests of RC elements strengthened with basalt FRP sheets.

  17. Evaluation of tensile bond strength of heat cure and autopolymerizing silicone-based resilient denture liners before and after thermocycling.

    PubMed

    Madan, Nishtha; Datta, Kusum

    2012-01-01

    To assess the effect of simulated mouth conditions reproduced with thermocycling on the tensile bond strength of two silicone based resilient denture liners with acrylic resin bases. Two silicone-based soft denture liners (Mollosil - Chairside autopolymerization and Molloplast B - Heat polymerization) were tested. For each liner, 30 specimens with a cross-sectional area of 10 Χ 10 mm and thickness 3 mm were processed between two acrylic blocks (Trevalon). Specimens were divided into a control group that was stored for 24 hours in water at 37°C and a test group that was thermocycled (2500 cycles) between baths of 5° and 55°C. Tensile bond strength (kg/cm²) was determined in a universal testing machine using crosshead speed of 5 mm/min. The student t-test was used to determine the significance of the difference in bond strength between the two liners. The mean tensile bond strength for control and thermocycled specimens of the two liners were: Mollosil (6.82 kg/cm² and 8.41 kg/cm²) and Molloplast-B (16.30 kg/cm² and 13.67 kg/cm²), respectively. Comparison of bond strength of control specimens with thermocycled specimens of the liners indicated a significant difference for both Mollosil (P=0.045) and Molloplast-B (P=0.027). Comparison between control specimens of both liners and thermocycled specimens of both liners indicated a highly significant difference (P<0.001). Heat polymerized resilient denture liner Molloplast-B had higher tensile bond strength than autopolymerizing liner Mollosil regardless of thermocycling. The bond strength of Mollosil increased after thermocycling while that of Molloplast-B decreased after thermocycling. Although heat-polymerized denture liners require more processing time than autopolymerizing liners, but they display much better adhesion properties to denture base resin and should thus be preferred when soft liner has to be used for a longer duration of time.

  18. The effect of cycling deflection on the injection-molded thermoplastic denture base resins.

    PubMed

    Hamanaka, Ippei; Iwamoto, Misa; Lassila, Lippo Vj; Vallittu, Pekka K; Shimizu, Hiroshi; Takahashi, Yutaka

    2016-01-01

    The aim of this study was to evaluate the effect of cycling deflection on the flexural behavior of injection-molded thermoplastic resins. Six injection-molded thermoplastic resins (two polyamides, two polyesters, one polycarbonate, one polymethyl methacrylate) and, as a control, a conventional heat-polymerized denture based polymer of polymethyl methacrylate (PMMA) were used in this study. The cyclic constant magnitude (1.0 mm) of 5000 cycles was applied using a universal testing machine to demonstrate plasticization of the polymer. Loading was carried out in water at 23ºC with eight specimens per group (n = 8). Cycling load (N) and deformation (mm) were measured. Force required to deflect the specimens during the first loading cycle and final loading cycle was statistically significantly different (p < 0.05) with one polyamide based polymer (Valplast) and PMMA based polymers (Acrytone and Acron). The other polyamide based polymer (LucitoneFRS), polyester based polymers (EstheShot and EstheShotBright) and polycarbonate based polymer (ReigningN) did not show significant differences (p > 0.05). None of the materials fractured during the loading test. One polyamide based polymer (Valplast) displayed the highest deformation and PMMA based polymers (Acrytone and Acron) exhibited the second highest deformation among the denture base materials. It can be concluded that there were considerable differences in the flexural behavior of denture base polymers. This may contribute to the fatigue resistance of the materials.

  19. A clinical study to evaluate denture adhesive use in well-fitting dentures.

    PubMed

    Munoz, Carlos A; Gendreau, Linda; Shanga, Gilbert; Magnuszewski, Tabetha; Fernandez, Patricia; Durocher, John

    2012-02-01

    The objective of this study was the assessment of retention and stability and functional benefits of denture adhesive applied to well-fitting and well-made dentures. This was a randomized, crossover study to compare two marketed denture adhesives (test cream, Super Poligrip® Free, and test strip, Super Poligrip® Comfort Seal Strips) and an unmarketed cream adhesive (GlaxoSmith Kline Consumer Healthcare) with no adhesive as the negative control. Thirty-six subjects completed the study. One hour after the application of denture adhesive, retention and stability were measured using the Kapur Index and maxillary incisal bite force. Two hours after application, functional tests were used to assess denture movement and peanut particle migration under the denture. Subjects also rated confidence, comfort, satisfaction with dentures, and denture wobble in conjunction with the functional tests. Denture adhesives significantly (p < 0.05) improved retention and stability of well-fitting dentures. Subjects experienced significantly (p < 0.05) fewer dislodgements while eating an apple after adhesive was applied to dentures. Significant (p < 0.05) increases in subjective ratings of confidence and comfort as well as decreases in denture wobble were associated with the use of adhesive. There was significant (p < 0.05) improvement in satisfaction ratings for cream adhesives. A single application of each denture adhesive was well tolerated. The results of this study provide evidence that use of Super Poligrip® denture adhesives can enhance aspects of performance of complete well-fitting dentures as well as provide increased comfort, confidence, and satisfaction with dentures. © 2011 by the American College of Prosthodontists.

  20. Meteosat SEVIRI Fire Radiative Power (FRP) products from the Land Surface Analysis Satellite Applications Facility (LSA SAF) - Part 1: Algorithms, product contents and analysis

    NASA Astrophysics Data System (ADS)

    Wooster, M. J.; Roberts, G.; Freeborn, P. H.; Xu, W.; Govaerts, Y.; Beeby, R.; He, J.; Lattanzio, A.; Mullen, R.

    2015-06-01

    Characterising changes in landscape scale fire activity at very high temporal resolution is best achieved using thermal observations of actively burning fires made from geostationary Earth observation (EO) satellites. Over the last decade or more, a series of research and/or operational "active fire" products have been developed from these types of geostationary observations, often with the aim of supporting the generation of data related to biomass burning fuel consumption and trace gas and aerosol emission fields. The Fire Radiative Power (FRP) products generated by the Land Surface Analysis Satellite Applications Facility (LSA SAF) from data collected by the Meteosat Second Generation (MSG) Spinning Enhanced Visible and Infrared Imager (SEVIRI) are one such set of products, and are freely available in both near real-time and archived form. Every 15 min, the algorithms used to generate these products identify and map the location of new SEVIRI observations containing actively burning fires, and characterise their individual rates of radiative energy release (fire radiative power; FRP) that is believed proportional to rates of biomass consumption and smoke emission. The FRP-PIXEL product contains the highest spatial resolution FRP dataset, delivered for all of Europe, northern and southern Africa, and part of South America at a spatial resolution of 3 km (decreasing away from the west African sub-satellite point) at the full 15 min temporal resolution. The FRP-GRID product is an hourly summary of the FRP-PIXEL data, produced at a 5° grid cell size and including simple bias adjustments for meteorological cloud cover and for the regional underestimation of FRP caused, primarily, by the non-detection of low FRP fire pixels at SEVIRI's relatively coarse pixel size. Here we describe the enhanced geostationary Fire Thermal Anomaly (FTA) algorithm used to detect the SEVIRI active fire pixels, and detail methods used to deliver atmospherically corrected FRP information together with the per-pixel uncertainty metrics. Using scene simulations and analysis of real SEVIRI data, including from a period of Meteosat-8 "special operations", we describe some of the sensor and data pre-processing characteristics influencing fire detection and FRP uncertainty. We show that the FTA algorithm is able to discriminate actively burning fires covering down to 10-4 of a pixel, and is more sensitive to fire than algorithms used within many other widely exploited active fire products. We also find that artefacts arising from the digital filtering and geometric resampling strategies used to generate level 1.5 SEVIRI data can significantly increase FRP uncertainties in the SEVIRI active fire products, and recommend that the processing chains used for the forthcoming Meteosat Third Generation attempt to minimise the impact of these types of operations. Finally, we illustrate the information contained within the current Meteosat FRP-PIXEL and FRP-GRID products, providing example analyses for both individual fires and multi-year regional-scale fire activity. A companion paper (Roberts et al., 2015) provides a full product performance evaluation for both products, along with examples of their use for prescribing fire smoke emissions within atmospheric modelling components of the Copernicus Atmosphere Monitoring Service (CAMS).

  1. Long-Term Soft Denture Lining Materials

    PubMed Central

    Chladek, Grzegorz; Żmudzki, Jarosław; Kasperski, Jacek

    2014-01-01

    Long-term soft denture lining (LTSDL) materials are used to alleviate the trauma associated with wearing complete dentures. Despite their established clinical efficacy, the use of LTSDLs has been limited due to the unfavorable effects of the oral environment on some of their mechanical and performance characteristics. The unresolved issue of LTSDL colonization by Candida albicans is particularly problematic. Silicone-based LTSDL (SLTSDL) materials, which are characterized by more stable hardness, sorption and solubility than acrylic-based LTSDLs (ALTSDLs), are currently the most commonly used LTSDLs. However, SLTSDLs are more prone to debonding from the denture base. Moreover, due to their limitations, the available methods for determining bond strength do not fully reflect the actual stability of these materials under clinical conditions. SLTSDL materials exhibit favorable viscoelastic properties compared with ALTSDLs. Furthermore, all of the lining materials exhibit an aging solution-specific tendency toward discoloration, and the available cleansers are not fully effective and can alter the mechanical properties of LTSDLs. Future studies are needed to improve the microbiological resistance of LTSDLs, as well as some of their performance characteristics. PMID:28788163

  2. The engineering of construction specifications for externally bonded FRP composites

    NASA Astrophysics Data System (ADS)

    Yang, Xinbao

    This dissertation, consisting of six technical papers, presents the results of research on the theme of developing engineering and the construction specifications for externally bonded FRP composites. For particular, the work focuses on three critical aspects of the performance of FRP systems: fiber misalignment, corner radius, and lap splice length. Based on both experimental and theoretical investigations, the main contribution of this work is the development of recommendations on fiber misalignment limit, minimum corner radius, lap splice length to be used as guidance in the construction practice of FRP strengthening of concrete structures. The first three papers focus on the strength and stiffness degradation of CFRP laminates from fiber misalignment. It was concluded that misalignment affects strength more than stiffness. In practice, when all fibers in a laminate can be regarded as through fibers, it is recommended to use a reduction factor for strength and no reduction factor for stiffness to account for fiber misalignment. Findings from concrete beams strengthened with misaligned CFRP laminates verified these recommendations. The fourth and fifth papers investigate the effect of corner radius on the mechanical properties of CFRP laminates wrapped around a rectangular cross section. A unique reusable test device was fabricated to determine fiber stress and radial stress of CFRP laminates with different corner radii. Comparison performed with finite element analyses shows that the test method and the reusable device were viable and the stress concentration needs to be considered in FRP laminate wrapped corners. A minimum of 1.0 in. corner radius was recommended for practice. The sixth paper summarizes the research on the lap splice length of FRP laminates under static and repeated loads. Although a lap splice length of 1.5 in. is sufficient for CFRP laminates to develop the ultimate static tensile strength, a minimum of 4.0 in. is recommended in order to account for repeated loads.

  3. Stiffness and strength of fiber reinforced polymer composite bridge deck systems

    NASA Astrophysics Data System (ADS)

    Zhou, Aixi

    This research investigates two principal characteristics that are of primary importance in Fiber Reinforced Polymer (FRP) bridge deck applications: STIFFNESS and STRENGTH. The research was undertaken by investigating the stiffness and strength characteristics of the multi-cellular FRP bridge deck systems consisting of pultruded FRP shapes. A systematic analysis procedure was developed for the stiffness analysis of multi-cellular FRP deck systems. This procedure uses the Method of Elastic Equivalence to model the cellular deck as an equivalent orthotropic plate. The procedure provides a practical method to predict the equivalent orthotropic plate properties of cellular FRP decks. Analytical solutions for the bending analysis of single span decks were developed using classical laminated plate theory. The analysis procedures can be extended to analyze continuous FRP decks. It can also be further developed using higher order plate theories. Several failure modes of the cellular FRP deck systems were recorded and analyzed through laboratory and field tests and Finite Element Analysis (FEA). Two schemes of loading patches were used in the laboratory test: a steel patch made according to the ASSHTO's bridge testing specifications; and a tire patch made from a real truck tire reinforced with silicon rubber. The tire patch was specially designed to simulate service loading conditions by modifying real contact loading from a tire. Our research shows that the effects of the stiffness and contact conditions of loading patches are significant in the stiffness and strength testing of FRP decks. Due to the localization of load, a simulated tire patch yields larger deflection than the steel patch under the same loading level. The tire patch produces significantly different failure compared to the steel patch: a local bending mode with less damage for the tire patch; and a local punching-shear mode for the steel patch. A deck failure function method is proposed for predicting the failure of FRP decks. Using developed laminated composite theories and FEA techniques, a strength analysis procedure containing ply-level information was proposed and detailed for FRP deck systems. The behavior of the deck's unsupported (free) edges was also investigated using ply-level FEA.

  4. Evaluation and comparison of transverse and impact strength of different high strength denture base resins.

    PubMed

    Gupta, Abhinav; Tewari, R K

    2016-01-01

    The present study was undertaken to evaluate and compare the impact strength and transverse strength of the high-impact denture base materials. A conventional heat polymerized acrylic resin was used as a control. The entire experiment was divided into four main groups with twenty specimens each according to denture base material selected Trevalon, Trevalon Hi, DPI Tuff and Metrocryl Hi. These groups were further subgrouped into the two parameters selected, impact strength and flexural strength with ten specimens each. These specimens were then subjected to transverse bend tests with the help of Lloyds instrument using a three point bend principle. Impact tests were undertaken using an Izod-Charpy digital impact tester. This study was analyzed with one-way analysis of variance using Fisher f-test and Bonferroni t-test. There was a significant improvement in the impact strength of high-impact denture base resins as compared to control (Trevalon). However, in terms of transverse bend tests, only DPI Tuff showed higher transverse strength in comparison to control. Trevalon Hi and Metrocryl Hi showed a decrease in transverse strength. Within the limits of this in vitro study, (1) There is a definite increase in impact strength due to the incorporation of butadiene styrene rubber in this high strength denture base materials as compared to Trevalon used as a control. (2) Further investigations are required to prevent the unduly decrease of transverse strength. (3) It was the limitation of the study that the exact composition of the high-impact resins was not disclosed by the manufacturer that would have helped in better understanding of their behavior.

  5. A randomized clinical trial comparing the efficacy of mandibular implant-supported overdentures and conventional dentures in diabetic patients. Part V: food preference comparisons.

    PubMed

    Roumanas, Eleni D; Garrett, Neal R; Hamada, Michael O; Diener, Randy M; Kapur, Krishan K

    2002-01-01

    The functional benefits of replacing old dentures with new conventional mandibular dentures or implant-supported overdentures has not been fully determined. This study assessed the impact of these 2 types of replacement dentures on the food choices of diabetic patients. A total of 68 diabetic patients with original complete dentures participated in this study. Diabetes was controlled with insulin in 38 patients (IT) and without insulin in 30 patients (NIT). All subjects received conventional maxillary dentures; 25 received mandibular conventional dentures (CD), and 43 received overdentures with plastic clips and a Hader bar attached to 2 osseointegrated implants (IOD). Subjects rated their perceptions of taste acceptability, texture acceptability, and chewing ease on a 4-point nominal scale and eating frequency on a 5-point scale for 13 specific foods at baseline (with original dentures) and at 6 months post-treatment completion (PTC). Fisher exact tests were used to compare the change in percentage distributions of responses with treatment. A 2 x 2 x 2 repeated-measures analysis of variance (ANOVA) was performed to compare mean scores between the 2 denture groups, 2 diabetic groups, and 2 time intervals for each of the 13 foods and 4 questions related to food acceptability. At baseline, no significant differences were found between the frequency distributions of responses in the CD and IOD groups or the IT and NIT groups for all 52 comparisons. With both types of study dentures, a higher percentage of patients perceived deterioration rather than improvement in function. When percentage distributions based on actual positive or negative change (treatment effect) in patient responses were compared, significant differences were found for 3 of the 52 responses, in favor of the IOD group. ANOVA demonstrated significant mean differences for 4 of the 52 comparisons. Both types of study dentures resulted in declines in the perceived taste and texture acceptability of almost all test foods. Declines in perceived chewing ease and eating frequency were more common and greater in the CD than in the IOD group. Both types of study dentures failed to affect food choices, as evidenced by declines or limited improvement in the perceived frequency with which most foods were eaten.

  6. Three-year clinical outcome of single implant-retained mandibular overdentures--results of preliminary prospective study.

    PubMed

    Harder, Sönke; Wolfart, Stefan; Egert, Christopher; Kern, Matthias

    2011-10-01

    The aim of this preliminary prospective study was to evaluate the clinical outcome, the oral health-related quality of life (OHRQoL), and the subjective chewing ability of patients with mandibular complete dentures retained by a single implant placed in the mandible midline. Patients wearing complete dentures were treated with a single implant in the mandible, followed by relining of the dentures and incorporation of ball attachments for implant retention. Implant outcome, prosthodontic maintenance, subjective chewing ability, and the oral health impact profile of the patients were assessed at baseline and at four weeks after connecting the denture and implant. Eleven patients were enrolled in this investigation, and the mean observation period was 43.4 months (minimum period: 35, maximum period: 52 months). No implants were lost during observation period, but four dentures needed repair because of the fracture of the denture base in the midline area. A significant improvement was observed in the OHRQoL of the patients after the attachment of the mandibular dentures with a single midline implant. Furthermore, the subjective chewing ability of the patients was significantly improved after implant connection. Within the limitations of this preliminary prospective clinical study, single implant-supported mandibular overdentures were a successful treatment option for older edentulous patients who showed improvements in their OHRQoL and chewing ability. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Comparative effects of pyrolytic products of fiber reinforced plastic and wood shavings on the respiratory variables in mice.

    PubMed

    Kumar, Pravin; Deb, Utsab; Gautam, Anshoo; Vijayaraghavan, R; Ratna, Debdatta; Chakraborty, B C

    2010-08-01

    Comparative inhalation toxicity studies of pyrolytic products (smoke) from synthetic polymer, fiberglass reinforced plastic (FRP) and teak wood shavings were carried out in male Swiss albino mice. The breathing pattern and the respiratory variables were monitored using a computer program that recognizes the modifications of the respiratory pattern. Exposure to the smoke from both the polymers caused a concentration dependent decrease in normal breathing and an increase in sensory irritation measure. The acute lethal concentration 50 values for a 15 min static inhalation exposure to the smoke from FRP and teak wood shavings were found to be > 200.00 and 62.99 g/m(3), respectively. Hence the inhalation toxicity of smoke from FRP sample on a mass basis is approximately one-third that of the smoke from teak wood. The concentration of smoke causing 50% respiratory depression of the exposed animals were found to be 6.877 and 0.106 g/m(3) for FRP and teak wood samples, respectively. Thus the sensory irritancy of the smoke from FRP sample is approximately 65 times lesser than the smoke from teak wood. The higher sensory irritancy potential of wood smoke as compared to FRP smoke may be caused by a greater number of submicron particles (size range of 2 micron and less) and greater percentage of gases present in wood smoke as compared to FRP smoke. Thus in case of accidental fires, synthetic polymers like FRP may be a safer choice for structural parts and interiors than the natural wood.

  8. Impact of removable dentures on oral health-related quality of life among elderly adults in Taiwan.

    PubMed

    Yen, Yea-Yin; Lee, Huey-Er; Wu, Yi-Min; Lan, Shou-Jen; Wang, Wen-Chen; Du, Je-Kang; Huang, Shun-Te; Hsu, Kun-Jung

    2015-01-05

    Although the use of removable dentures can improve oral function and esthetics for elderly people, compared to those who do not wear removable dentures, those wearing removable dentures could have worse oral health related-quality of life (OHRQoL). Additional information is required to assess which factors related to denture wearing influence the OHRQoL of elderly individuals. The purpose of this study is to evaluate the association between denture wearing and OHRQoL in a sample of elderly individuals in Taiwan. The study population included 277 elderly people wearing removable dentures (mean age = 76.0 years). Using face-to-face interviews, we collected data on the participants' socio-demographic characteristics, dental care service usage (regular dental checkups, treatment during toothache, dental visits in the last year), and factors related to denture wearing (perceived oral pain, perceived loose denture, perceived oral ulcer, perceived halitosis, perceived dry mouth, and perceived total denture satisfaction scores). OHRQoL was measured using the Taiwanese version of the Geriatric Oral Health Assessment Index (GOHAI-T). The location and number of remaining natural teeth and the type of denture were also recorded. Hierarchical multiple regression analysis was performed using GOHAI-T scores as the dependent variable. All the predictors together accounted for 50% of the variance in GOHAI-T scores. Further, education level, number of natural teeth, denture status, perceived loose denture, perceived oral ulcer, and perceived total denture satisfaction scores had statistically significant influences on OHRQoL. When compared with other variables, factors related to denture wearing, especially perceived total denture satisfaction scores, had the greatest impact on GOHAI-T scores. Of the factors analyzed in this study, denture satisfaction was the strongest predictor of OHRQoL. This suggests that denture satisfaction is useful for assessing the effect of denture treatment on the OHRQoL of elderly individuals wearing removable dentures.

  9. Antimicrobial activity of denture adhesive associated with Equisetum giganteum- and Punica granatum-enriched fractions against Candida albicans biofilms on acrylic resin surfaces.

    PubMed

    Almeida, Nara Ligia Martins; Saldanha, Luiz Leonardo; da Silva, Rafaela Alves; Pinke, Karen Henriette; da Costa, Eliane Ferraz; Porto, Vinicius Carvalho; Dokkedal, Anne Lígia; Lara, Vanessa Soares

    2018-01-01

    Candida biofilms adhere to the internal surface of removable dentures, which is an etiological factor in the pathogenesis of denture stomatitis (DS). Adhesive materials are used at the base of maxillary complete dentures to improve their retention and chewing qualities. This article reports the antimicrobial activity of the enriched fractions of Equisetum giganteum and Punica granatum incorporated into a denture adhesive against C. albicans biofilm. The biofilms were induced on the surface of heat-cured acrylic resin specimens that were previously treated with a mixture of adhesive/herb extracts. The antimicrobial activity was evaluated by CFU counts, XTT reduction, and SEM and CLSM analysis. Both herb extracts amplified the anti-biofilm action of the adhesive on the acrylic resin by up to 12 h. Therefore, when these extracts were combined with COREGA®, they played a collaborative and innovative role in biofilm control and can be considered alternatives for temporary use in the treatment and/or prevention of DS.

  10. Complete denture tooth arrangement technology driven by a reconfigurable rule.

    PubMed

    Dai, Ning; Yu, Xiaoling; Fan, Qilei; Yuan, Fulai; Liu, Lele; Sun, Yuchun

    2018-01-01

    The conventional technique for the fabrication of complete dentures is complex, with a long fabrication process and difficult-to-control restoration quality. In recent years, digital complete denture design has become a research focus. Digital complete denture tooth arrangement is a challenging issue that is difficult to efficiently implement under the constraints of complex tooth arrangement rules and the patient's individualized functional aesthetics. The present study proposes a complete denture automatic tooth arrangement method driven by a reconfigurable rule; it uses four typical operators, including a position operator, a scaling operator, a posture operator, and a contact operator, to establish the constraint mapping association between the teeth and the constraint set of the individual patient. By using the process reorganization of different constraint operators, this method can flexibly implement different clinical tooth arrangement rules. When combined with a virtual occlusion algorithm based on progressive iterative Laplacian deformation, the proposed method can achieve automatic and individual tooth arrangement. Finally, the experimental results verify that the proposed method is flexible and efficient.

  11. Design and Fabrication of FRP Truck Trailer Side Racks.

    DTIC Science & Technology

    1983-08-01

    0.100 in. All contact surfaces in the mold were sealed with white shellac and finished with five coats of carnauba wax . The completed mold is shown in...Figure 10. 15 II Figure 10. FRP prototype mold. FRP molding procedures were duplicated for each part produced. In general, the waxed mold was coated

  12. Evaluation of the efficiency of denture cleaners for removing denture adhesives.

    PubMed

    Harada-Hada, Kae; Hong, Guang; Abekura, Hitoshi; Murata, Hiroshi

    2016-12-01

    We developed a new scoring index for assessing the removability of denture adhesives and evaluated the removal efficiency of denture cleaners. Although our understanding of the importance of denture care is increasing, little is known about the effectiveness and efficiency of denture cleaners on denture adhesives. Therefore, guidelines for proper cleaning are necessary. We used five denture cleaner solutions on two cream adhesives, one powder adhesive and one cushion adhesive. After immersion in the denture cleaners for a designated time, we evaluated the area of the sample plate still covered by denture adhesive. Cream adhesives were removed more completely after immersion in majority of the denture cleaners than in water. Powder adhesive was removed more quickly than cream adhesives. Cushion adhesive was not removed by immersion in either the denture cleaners or water control. Some denture cleaners could liquefy cream adhesives more than water, but these differences were not observed in case of powder and cushion adhesives. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  13. A review of the application Acoustic Emission (AE) incorporating mechanical approach to monitor Reinforced concrete (RC) strengthened with Fiber Reinforced Polymer (FRP) properties under fracture

    NASA Astrophysics Data System (ADS)

    Syed Mazlan, S. M. S.; Abdullah, S. R.; Shahidan, S.; Noor, S. R. Mohd

    2017-11-01

    Concrete durability may be affected by so many factors such as chemical attack and weathering action that reduce the performance and the service life of concrete structures. Low durability Reinforced concrete (RC) can be greatly improved by using Fiber Reinforce Polymer (FRP). FRP is a commonly used composite material for repairing and strengthening RC structures. A review on application of Acoustic Emission (AE) techniques of real time monitoring for various mechanical tests for RC strengthened with FRP involving four-point bending, three-point bending and cyclic loading was carried out and discussed in this paper. Correlations between each AE analyses namely b-value, sentry and intensity analysis on damage characterization also been critically reviewed. From the review, AE monitoring involving RC strengthened with FRP using b-value, sentry and intensity analysis are proven to be successful and efficient method in determining damage characterization. However, application of AE analysis using sentry analysis is still limited compared to b-value and intensity analysis in characterizing damages especially for RC strengthened with FRP specimen.

  14. Tensile and fatigue behavior of polymer composites reinforced with superelastic SMA strands

    NASA Astrophysics Data System (ADS)

    Daghash, Sherif M.; Ozbulut, Osman E.

    2018-06-01

    This study explores the use of superelastic shape memory alloy (SMA) strands, which consist of seven individual small-diameter wires, in an epoxy matrix and characterizes the tensile and fatigue responses of the developed SMA/epoxy composites. Using a vacuum assisted hand lay-up technique, twelve SMA fiber reinforced polymer (FRP) specimens were fabricated. The developed SMA-FRP composites had a fiber volume ratio of 50%. Tensile response of SMA-FRP specimens were characterized under both monotonic loading and increasing amplitude loading and unloading cycles. The degradation in superelastic properties of the developed SMA-FRP composites during fatigue loading at different strain amplitudes was investigated. The effect of loading rate on the fatigue response of SMA-FRP composites was also explored. In addition, fractured specimens were examined using the scanning electron microscopy (SEM) technique to study the failure mechanisms of the tested specimens. A good interfacial bonding between the SMA strands and epoxy matrix was observed. The developed SMA-FRP composites exhibited good superelastic behavior at different strain amplitudes up to at least 800 cycle after which significant degradation occurred.

  15. Contour scanning of textile preforms using a light-section sensor for the automated manufacturing of fibre-reinforced plastics

    NASA Astrophysics Data System (ADS)

    Schmitt, R.; Niggemann, C.; Mersmann, C.

    2008-04-01

    Fibre-reinforced plastics (FRP) are particularly suitable for components where light-weight structures with advanced mechanical properties are required, e.g. for aerospace parts. Nevertheless, many manufacturing processes for FRP include manual production steps without an integrated quality control. A vital step in the process chain is the lay-up of the textile preform, as it greatly affects the geometry and the mechanical performance of the final part. In order to automate the FRP production, an inline machine vision system is needed for a closed-loop control of the preform lay-up. This work describes the development of a novel laser light-section sensor for optical inspection of textile preforms and its integration and validation in a machine vision prototype. The proposed method aims at the determination of the contour position of each textile layer through edge scanning. The scanning route is automatically derived by using texture analysis algorithms in a preliminary step. As sensor output a distinct stage profile is computed from the acquired greyscale image. The contour position is determined with sub-pixel accuracy using a novel algorithm based on a non-linear least-square fitting to a sigmoid function. The whole contour position is generated through data fusion of the measured edge points. The proposed method provides robust process automation for the FRP production improving the process quality and reducing the scrap quota. Hence, the range of economically feasible FRP products can be increased and new market segments with cost sensitive products can be addressed.

  16. High-resolution nondestructive testing of multilayer dielectric materials using wideband microwave synthetic aperture radar imaging

    NASA Astrophysics Data System (ADS)

    Kim, Tae Hee; James, Robin; Narayanan, Ram M.

    2017-04-01

    Fiber Reinforced Polymer or Plastic (FRP) composites have been rapidly increasing in the aerospace, automotive and marine industry, and civil engineering, because these composites show superior characteristics such as outstanding strength and stiffness, low weight, as well as anti-corrosion and easy production. Generally, the advancement of materials calls for correspondingly advanced methods and technologies for inspection and failure detection during production or maintenance, especially in the area of nondestructive testing (NDT). Among numerous inspection techniques, microwave sensing methods can be effectively used for NDT of FRP composites. FRP composite materials can be produced using various structures and materials, and various defects or flaws occur due to environmental conditions encountered during operation. However, reliable, low-cost, and easy-to-operate NDT methods have not been developed and tested. FRP composites are usually produced as multilayered structures consisting of fiber plate, matrix and core. Therefore, typical defects appearing in FRP composites are disbondings, delaminations, object inclusions, and certain kinds of barely visible impact damages. In this paper, we propose a microwave NDT method, based on synthetic aperture radar (SAR) imaging algorithms, for stand-off imaging of internal delaminations. When a microwave signal is incident on a multilayer dielectric material, the reflected signal provides a good response to interfaces and transverse cracks. An electromagnetic wave model is introduced to delineate interface widths or defect depths from the reflected waves. For the purpose of numerical analysis and simulation, multilayered composite samples with various artificial defects are assumed, and their SAR images are obtained and analyzed using a variety of high-resolution wideband waveforms.

  17. [Study of the appearance difference of lower complete denture between functional and anatomic impression techniques].

    PubMed

    Zhong, Qun; Wu, Xue-yin; Shen, Qing-yi; Shen, Qing-ping

    2012-04-01

    To compare the difference in oblique external ridge, oblique internal ridge and alveolar process crest of lower complete denture base made through functional impression and anatomic impression techniques. Fifteen patients were chosen to treat with two kinds of complete dentures through functional impression and anatomic impression technique respectively. 3D laser scanner was used to scan the three-dimensional model of the denture base and the differences of the surface structural between two techniques in alveolar process crest, external and internal oblique ridges were analyzed, using paired t test with SPSS 12.0 software package. Between the two techniques, there were significant differences in the areas of internal and external oblique ridge(P<0.01); there was no significant difference in the main support areas(P>0.05). The results explain why there is less tenderness when functional impression technique is applied. The differences measured also indicate that sufficient buffering should be made in external and internal oblique ridge areas in clinic.

  18. Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.

    PubMed

    Gundogdu, Mustafa; Yesil Duymus, Zeynep; Alkurt, Murat

    2014-10-01

    Adhesive failure between acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to evaluate the effect of different surface treatments on the bond strength of 2 different resilient lining materials to an acrylic resin denture base. Ninety-six dumbbell-shaped specimens were fabricated from heat-polymerized acrylic resin, and 3 mm of the material was cut from the thin midsection. The specimens were divided into 6 groups according to their surface treatments: no surface treatment (control group), 36% phosphoric acid etching (acid group), erbium:yttrium-aluminum-garnet (Er:YAG) laser (laser group), airborne-particle abrasion with 50-μm Al2O3 particles (abrasion group), an acid+laser group, and an abrasion+laser group. The specimens in each group were divided into 2 subgroups according to the resilient lining material used: heat-polymerized silicone based resilient liner (Molloplast B) and autopolymerized silicone-based resilient liner (Ufi Gel P). After all of the specimens had been polymerized, they were stored in distilled water at 37°C for 1 week. A tensile bond strength test was then performed. Data were analyzed with a 2-way ANOVA, and the Sidak multiple comparison test was used to identify significant differences (α=.05). The effects of the surface treatments and resilient lining materials on the surface of the denture base resin were examined with scanning electron microscopy. The tensile bond strength was significantly different between Molloplast B and Ufi Gel P (P<.001). The specimens of the acid group had the highest tensile bond strength, whereas those of the abrasion group had the lowest tensile bond strength. The scanning electron microscopy observations showed that the application of surface treatments modified the surface of the denture base resin. Molloplast B exhibited significantly higher bond strength than Ufi Gel P. Altering the surface of the acrylic resin denture base with 36% phosphoric acid etching increased bond strength. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of gloss changes of two denture acrylic resin materials in four different beverages.

    PubMed

    Keyf, Filiz; Etikan, Ilker

    2004-03-01

    The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin. Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p < or = 0.05 significant), the Kruskal-Wallis analysis of variance (p < or = 0.05 significant) and the Mann-Whitney U-test with Bonforoni correction (when the difference between the samples was significant) (p < or = 0.05 significant). The results of this study revealed that gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p < or = 0.05). According to the Kruskal-Wallis analysis of variance, the difference between measurements for angles of illumination was statistically significant (p < or = 0.05). Also according to the Mann-Whitney U-test, the difference between two polished surfaces or two unpolished surfaces was statistically insignificant (p > 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p < or = 0.05). It was found that either the gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages demonstrated noticeable gloss changes. Cherry juice demonstrated the least change, while tea exhibited the greatest change.

  20. IMPROVDENT: improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures.

    PubMed

    Gray, Janine C; Navarro-Coy, Nuria; Pavitt, Sue H; Hulme, Claire; Godfrey, Mary; Craddock, Helen L; Brunton, Paul A; Brown, Sarah; Dillon, Sean; Dukanovic, Gillian; Fernandez, Catherine; Wright, Jonathan; Collier, Howard; Swithenbank, Shirley; Lee, Carol; Hyde, T Paul

    2012-08-31

    According to the UK Adult Dental Health Survey (2009) 15% of adults aged 65-74, 30% aged 75-84 and 47% aged >85 years are edentulous and require complete dentures. Patients' quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone). Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period). Patients will then wear each set of dentures for a period of 8 weeks (in random order) during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period).Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference) and confirmation period (adjusted denture preference). A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300). This trial aims to provide evidence on the costs and quality of dentures cast from two different commonly used impression materials; the intention is to significantly impact on the quality of denture production within NHS dentistry. ISRCTN Register: ISRCTN01528038 UKCRN Portfolio ID: 8305.

  1. Influence of psychological factors on the acceptance of complete dentures.

    PubMed

    al Quran, F; Clifford, T; Cooper, C; Lamey, P J

    2001-07-01

    To assess the influence of psychological factors on the acceptance of complete dentures in a population wearing dentures judged to be clinically satisfactory. Subjects were asked to complete personality profiles and also to rate their dentures using a denture satisfaction questionnaire. The survey was conducted in the prosthetics clinic of a teaching hospital. Patients were selected from those who had new complete dentures constructed in the department within the previous two years. The personality inventory was a self-administered questionnaire comprising 240 items covering the five domains of personality. Denture satisfaction was scored on a nine item scale with four Likert type responses to each. A group of 16% consistently complained about their dentures. Statistical analysis showed that personality factors especially Neuroticism had a significant relationship with denture satisfaction. Psychological factors significantly influence denture satisfaction and profiles may provide useful in predicting potential difficult denture wearers.

  2. Dentist-Patient Communication and Denture Quality Associated with Complete Denture Satisfaction Among Taiwanese Elderly Wearers.

    PubMed

    Chen, Jen-Hao; Huang, Hsiao-Ling; Lin, Ying-Chun; Chou, Tsau-Mau; Ebinger, John; Lee, Huey-Er

    2015-01-01

    The aim of this study was to explore individual (ie, sociodemographic characteristics, patient personality) and clinical factors (ie, dentist-patient communication, denture quality) associated with complete denture satisfaction among the Taiwanese elderly population. A multistage sampling and cross-sectional design was used to collect data. A total of 387 fully edentulous citizens, aged 65 years and older and who had received new sets of complete dentures, were selected. The participants completed clinical dental examinations and questionnaires by personal interview to collect information on denture satisfaction and associated variables. The relationship among three groups of these participants (satisfied, neutral, and dissatisfied) and potential factors were simultaneously examined using polytomous logistic regression analysis. Overall, 36.7% of the participants were dissatisfied with their dentures. Living status (crude odds ratio [COR] = 2.04), personality (COR = 4.86), dentist-patient communication (COR = 7.46), and denture quality (COR = 5.02) were associated with complete denture satisfaction. The multivariate regression model showed that dentist-patient communication (adjusted odds ratio [AOR] = 6.41) and denture quality (AOR = 4.40) were significant complete denture satisfaction factors that diluted the effect of living status and personality. Inadequate dentistpatient communication and low denture quality were associated with the dissatisfaction of patients with dentures. To increase complete denture satisfaction, the importance of training programs aimed at enhancing dentist-patient communication and denture quality cannot be overemphasized.

  3. Nonlinear behaviors of FRP-wrapped tall trees subjected to high wind loads

    NASA Astrophysics Data System (ADS)

    Kang, J.; Yi, Z. Z.; Choi, S. G.

    2017-12-01

    This study investigated the mechanical stability of historical tall trees wrapped with fiber-reinforced polymer (FRP) laminates using finite element (FE) analysis. High wind loads are considered as external loading conditions as they are one of the major threats on the structural stability of tall old trees. There have been several traditional practices to enhance the stability of tall trees exposed to high windstorms such as tree supporters and anchorages. They, however, have been sometimes causing negative effects with their misuses as the application guidelines for those methods were not adequately studied or documented. Furthermore, the oldest known trees in the country should be protected from the damage of external surface as well as ruin of the landscape. The objective of this study was to evaluate the structural effects of FRP wraps applied to tall trees subjected to high wind loads. The anisotropic material properties of wood and FRP laminates were considered in the analysis in addition to geometrically nonlinear behaviors. This study revealed that FRP wrapping for tall trees could effectively reduce the deflections and maximum stresses of trees, which results in the enhanced stability of tall trees. The optimum geometry and thicknesses of FRP wraps proposed in this study would provide fundemental guidelines for designing and constructing the application of innovative FRP wraps on tall trees, which are structurally unstable or should be preserved nationally and historically.

  4. Incremental dynamic analysis of concrete moment resisting frames reinforced with shape memory composite bars

    NASA Astrophysics Data System (ADS)

    Zafar, Adeel; Andrawes, Bassem

    2012-02-01

    Fiber reinforced polymer (FRP) reinforcing bars have been used in concrete structures as an alternative to conventional steel reinforcement, in order to overcome corrosion problems. However, due to the linear behavior of the commonly used reinforcing fibers, they are not considered in structures which require ductility and damping characteristics. The use of superelastic shape memory alloy (SMA) fibers with their nonlinear elastic behavior as reinforcement in the composite could potentially provide a solution for this problem. Small diameter SMA wires are coupled with polymer matrix to produce SMA-FRP composite, which is sought in this research as reinforcing bars. SMA-FRP bars are sought in this study to enhance the seismic performance of reinforced concrete (RC) moment resisting frames (MRFs) in terms of reducing their residual inter-story drifts while still maintaining the elastic characteristics associated with conventional FRP. Three story one bay and six story two bay RC MRF prototype structures are designed with steel, SMA-FRP and glass-FRP reinforcement. The incremental dynamic analysis technique is used to investigate the behaviors of the two frames with the three different reinforcement types under a suite of ground motion records. It is found that the frames with SMA-FRP composite reinforcement exhibit higher performance levels including lower residual inter-story drifts, high energy dissipation and thus lower damage, which are important for structures in highly seismic zones.

  5. Hader bar and clip attachment retained mandibular complete denture

    PubMed Central

    Singh, Kunwarjeet; Gupta, Nidhi; Kapoor, Vikram; Gupta, Ridhimaa

    2013-01-01

    Bar and clip attachments significantly improve the level of satisfaction of denture-wearing patients by enhancing the retention and stability of the prosthesis. These attachments have been most commonly used for connecting the prosthesis to implants, but they can be effectively used to retain tooth-supported prosthesis as well. The primary functions of bar attachments are splinting the abutments together, even distribution of forces to the abutments and supporting areas, guiding the prosthesis into place, improving the retention, stability, support and comfort of the patient. The primary requirement for the use of bar attachments is the availability of sufficient vertical and buccolingual space for the proper placement of the bar, sleeves, teeth arrangement and sufficient thickness of acrylic denture base to minimise incidence of denture fracture in the area of bar assembly. PMID:24145505

  6. Hader bar and clip attachment retained mandibular complete denture.

    PubMed

    Singh, Kunwarjeet; Gupta, Nidhi; Kapoor, Vikram; Gupta, Ridhimaa

    2013-10-21

    Bar and clip attachments significantly improve the level of satisfaction of denture-wearing patients by enhancing the retention and stability of the prosthesis. These attachments have been most commonly used for connecting the prosthesis to implants, but they can be effectively used to retain tooth-supported prosthesis as well. The primary functions of bar attachments are splinting the abutments together, even distribution of forces to the abutments and supporting areas, guiding the prosthesis into place, improving the retention, stability, support and comfort of the patient. The primary requirement for the use of bar attachments is the availability of sufficient vertical and buccolingual space for the proper placement of the bar, sleeves, teeth arrangement and sufficient thickness of acrylic denture base to minimise incidence of denture fracture in the area of bar assembly.

  7. 21 CFR 872.3165 - Precision attachment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... conjunction with removable partial dentures. Various forms of the device are intended to connect a lower partial denture with another lower partial denture, to connect an upper partial denture with another upper partial denture, to connect either an upper or lower partial denture to a tooth or a crown, or to connect...

  8. Denture plaque--past and recent concerns.

    PubMed

    Nikawa, H; Hamada, T; Yamamoto, T

    1998-05-01

    This paper critically reviews the history of denture plaque and identifies some concerns with the presence of Candida in the mouth. This review covers literature sources related to Candida albicans and its relationship to denture plaque. The articles selected for this review are from referred journals and describe C. albicans and its relationship to oral, gastrointestinal and pleuropulmonary infections. The relationship to caries, root caries and periodontal disease is also covered. Denture plaque containing Candida could cause not only oral candidiasis, like oral thrush or denture-induced stomatitis, but also caries, root caries and periodontitis of abutment teeth. However, there is only limited experimental evidence or information available on the cariogenicity of Candida. The continuous swallowing or aspiration of micro-organisms from denture plaque exposes patients, particularly the immunocompromised host or medicated elderly, to the risks of unexpected infections. The term, 'denture plaque' has been used throughout the review. However, the term 'plaque on denture' should be used because the microbial flora and its pathogenicity of denture plaque resembles those of plaque formed on the tooth surface, so called dental plaque. In addition, the term 'denture related stomatitis' would be preferable to 'denture induced stomatitis', since the inflammation of (palatal) mucosa is not induced by the denture, but by wearing the denture or by plaque on the denture.

  9. Clinical evaluation of three denture cushion adhesives by complete denture wearers.

    PubMed

    Koronis, Spyros; Pizatos, Evangelos; Polyzois, Gregory; Lagouvardos, Panagiotis

    2012-06-01

    The aim of this study was the clinical evaluation of three denture cushion adhesives and whether the results were correlated to Kapur Index for denture-supporting tissues. Various types of denture adhesives are used among denture patients. However, information on the clinical behaviour of denture cushions is limited. Thirty edentulous patients had their denture-supporting tissues scored by Kapur Index and their old dentures replaced. They received three brands of denture cushion adhesives (Fittydent(®) , Protefix(®) and Seabond(®)) and were instructed to use them in a sequence according to the group they were randomly assigned to. Each brand of adhesive was used for 48 h on the lower denture according to the manufacturer's suggestions. After each brand was used, participants spent 24 h without applying any sort of adhesive. Finally, a questionnaire evaluating and comparing the performance of each brand was filled out. Denture adhesives generally improved patient satisfaction and masticatory ability, especially in participants with poor Kapur Index and those who reported a poor retention of their old dentures. Fittydent(®) was the most preferred adhesive, showing the best retention and the longest duration of its effect, but also reported as difficult to remove from the denture-bearing area. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  10. Bridge-in-a-backpack(TM) task 3.3 : investigate soil-structure interaction-modeling and experimental results of concrete filled FRP tube arches.

    DOT National Transportation Integrated Search

    2015-12-01

    This report includes fulfillment of Task 3.3 of a multi-task contract to further enhance concrete filled FRP tubes, or : the Bridge in a Backpack. Task 3 is an investigation of soil-structure interaction for the FRP tubes. Task 3.3 is the : modeling ...

  11. Influence of denture surface roughness and host factors on dental calculi formation on dentures: a cross-sectional study.

    PubMed

    Matsumura, Keisuke; Sato, Yuji; Kitagawa, Noboru; Shichita, Toshiharu; Kawata, Daisuke; Ishikawa, Mariko

    2018-05-04

    Dental calculi formation on dentures can worsen the oral cavity environment by complicating oral hygiene. However, few studies have investigated the effect of how patients use and manage their dentures, denture surface roughness, and host factors such as oral cavity dryness and saliva properties on denture cleanliness and denture dental calculi formation. Accordingly, we conducted the present survey to evaluate these factors to clarify the strength of the influence of each factor. We enrolled 53 patients who had used dentures for at least 3 months and used a dental prosthesis that covered at least the six front teeth including the left and right mandibular canines. After staining the dentures, we divided the participants into a group that was positive for dental calculi (DCP group) and a group that was negative for dental calculi (DCN group). After removing all the stains, we evaluated the surface roughness of the dentures. A questionnaire was used to survey how the participants used and managed their dentures. Oral cavity dryness was evaluated, and resting saliva samples were collected to assess saliva properties. Correlations between the presence or absence of dental calculi and denture use and management were evaluated using a chi-square test. Correlations with denture surface roughness, oral cavity dryness, and saliva properties were evaluated using the Mann-Whitney U test. Correlations between the presence or absence of dental calculi and all factors were analyzed using multivariate analysis (quantification II). Surface roughness was significantly greater in the DCP group (p < 0.01), and the DCP group members wore their dentures during sleep significantly more often and used a denture cleaner when storing their dentures significantly less often (both p < 0.01). No significant differences were observed for oral cavity dryness or saliva properties. The multivariate analysis showed significant correlations of dental calculi formation with denture surface roughness and items related to denture use and management, but not for oral cavity dryness or saliva properties. Our findings indicate that dental calculi formation is influenced by how dentures are used and managed and by denture surface roughness, but not by oral cavity dryness and saliva properties.

  12. A Simplified Technique to Measure Plaque on the Intaglio Surfaces of Complete Dentures.

    PubMed

    Almas, Khalid; Salameh, Ziad; Kutkut, Ahmad; Al Doubali, Ahmad

    2015-04-01

    The main aim of this study was to develop a simplified quantitative denture plaque index that could help dentists to motivate denture patients to maintain optimal oral hygiene. The secondary aim was to assess specific areas of dentures more prone to accumulate plaque and subjects' oral hygiene habits related to their dentures. One hundred subjects who wore maxillary and/or mandibular complete dentures for at least one year were included in the study as a powered sample. Fifteen females and 85 males, age range 45-75 years, were recruited. The study was carried out at King Saud University (KSU), College of Dentistry. A plaque disclosing solution was used to assess the plaque covered areas of denture. A quantitative percentage (10 x 10%) score index was developed by assessing plaque scores from digital images of intaglio surfaces of the dentures. The weighted kappa method was used to assess inter-examiner agreement in the main study. The new denture plaque index was identified as ASKD-DPI (Almas, Salameh, Kutkut, and Doubali-Denture Plaque Index). It ranged from 0 - 100%, and reflected the percentage of the intaglio surfaces of maxillary and mandibular complete dentures that contained plaque. It also classified quantitative percentages: 30 subjects ranged from 0 - 30% (low DPI), 50 subjects ranged from 31 - 70% (moderate DPI), and 20 subjects ranged from 71 - 100% (high DPI) denture plaque score. A simplified denture plaque index (ASKD-DPI) technique was developed and tested in this study. ASKD-DPI may be used for evaluating denture plaque scores, monitoring denture hygiene, and measuring compliance of patients regarding plaque control for complete dentures.

  13. Quality of Life with Removable Dentures

    PubMed Central

    Hadzipasic-Nazdrajic, Amra

    2011-01-01

    Goal: To measure change in a quality of life after treatment with removable dentures and to describe differences in quality of life in patients with new and worn out dentures. Materials and methods: Measuring instrument was OHIP-49, translated from English into one of the languages in Bosnia-Herzegovina. Sample consisted of patients who wanted to make/replace mobile dentures or came to repair a broken dentures. Comprehensibility of the OHIP-BH49 was tested on a sub-sample of patients. Three measurements were made: before and after the insertion of dentu res and when patients came to repair their mobile dentures. Results: Sample consisted of 67 patients: 32 patients who sought prosthetic treatment, and 35 who came to repair their broken dentures. We received 89.7% correctly filled questionnaires. Minor changes were made in four (4) questions. Statistical analysis performed with the T-test revealed the significant differences, before and after the treatment with mobile dentures (t=39.5, p<0.001). There was a significant difference in OHIP scores in patients with a new dentures, compared to the patients who had worn out dentures (t=44.30, p<0.001). Substantial differences, between OHIP scores, regarding the time of wearing dentures or patients’ age were not observed. Discussion: Patients who wore dentures longer than 5 years, showed better quality of life, because they became accustomed to the dentures. Conclusions: Self-reported life quality improved considerably after insertion of a new dentures. Patients with a new dentures showed significantly better quality of life than patients with worn out dentures. One part of OHIP validation in Bosnia-Herzegovina has been done. PMID:23678299

  14. Development of a nondestructive evaluation method for FRP bridge decks

    NASA Astrophysics Data System (ADS)

    Brown, Jeff; Fox, Terra

    2010-05-01

    Open steel grids are typically used on bridges to minimize the weight of the bridge deck and wearing surface. These grids, however, require frequent maintenance and exhibit other durability concerns related to fatigue cracking and corrosion. Bridge decks constructed from composite materials, such as a Fiber-reinforced Polymer (FRP), are strong and lightweight; they also offer improved rideability, reduced noise levels, less maintenance, and are relatively easy to install compared to steel grids. This research is aimed at developing an inspection protocol for FRP bridge decks using Infrared thermography. The finite element method was used to simulate the heat transfer process and determine optimal heating and data acquisition parameters that will be used to inspect FRP bridge decks in the field. It was demonstrated that thermal imaging could successfully identify features of the FRP bridge deck to depths of 1.7 cm using a phase analysis process.

  15. A model for predicting the shear bearing capacity of FRP-strengthened beams

    NASA Astrophysics Data System (ADS)

    Sas, G.; Carolin, A.; Täljsten, B.

    2008-05-01

    The shear failure of reinforced concrete beams needs more attention than the bending failure since no or only small warning precedes the failure. For this reason, it is of utmost importance to understand the shear bearing capacity and also to be able to undertake significant rehabilitation work if necessary. In this paper, a design model for the shear strengthening of concrete beams by using fiber-reinforced polymers (FRP) is presented, and the limitations of the truss model analogy are highlighted. The fracture mechanics approach is used in analyzing the bond behavior between the FRP composites and concrete. The fracture energy of concrete and the axial rigidity of the FRP are considered to be the most important parameters. The effective strain in the FRP when the debonding occurs is determined. The limitations of the anchorage length over the cross section are analyzed. A simple iterative design method for the shear debonding is finally proposed.

  16. Improvdent: Improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures

    PubMed Central

    2012-01-01

    Background According to the UK Adult Dental Health Survey (2009) 15% of adults aged 65–74, 30% aged 75–84 and 47% aged >85 years are edentulous and require complete dentures. Patients’ quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. Methods/Design IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone). Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period). Patients will then wear each set of dentures for a period of 8 weeks (in random order) during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period). Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference) and confirmation period (adjusted denture preference). A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. Funding: IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300). Discussion This trial aims to provide evidence on the costs and quality of dentures cast from two different commonly used impression materials; the intention is to significantly impact on the quality of denture production within NHS dentistry. Trial Registration ISRCTN Register: ISRCTN01528038 UKCRN Portfolio ID: 8305 PMID:22937901

  17. Hardness and surface roughness of enamel and base layers of resin denture teeth after long-term repeated chemical disinfection.

    PubMed

    Neppelenbroek, Karin Hermana; Kurokawa, Luciana Ayumi; Procópio, Andréa Lemos Falcão; Pegoraro, Thiago Amadei; Hotta, Juliana; Mello Lima, Jozely Francisca; Urban, Vanessa Migliorini

    2015-01-01

    To evaluate the effect of successive cycles of disinfection in different denture cleansers on the surface roughness and the Vickers hardness of two layers of acrylic resin (base-BL and enamel-EL) of two commercial cross-linked artificial teeth. The occlusal surfaces of 60 acrylic resin denture posterior teeth (Trilux-TLX and SR Orthosit PE-SRO) embedded in autopolymerizing acrylic resin were ground fat with 1200-grit silicon carbide paper. Specimens were stored in distilled water at 37°C and then submitted to the microhardness (VHN) and roughness (μm) tests. Specimens were stored in distilled water at 37°C for 90 days and submitted to 720 disinfection cycles in sodium hypochlorite at 0.5%, 30% vinegar solution or distilled water (control). Afterward, micro-hardness and roughness tests were again performed. Data were analyzed using two-way ANOVA and Tukey's test (α=0.05). Hypochlorite immersion decreased the hardness of BL and EL of SRO teeth, with an average reduction of 10.11% (p<0.008). TLX teeth demonstrated a hardness reduction of 28.96% of both layers for all solutions including water (p<0.0000). The roughness of both teeth was not affected by denture cleansers (p>0.37). Hypochlorite promoted deleterious effects on the hardness of both layers of the artificial teeth tested. Immersion in vinegar and water also resulted in reduction of hardness of TLX teeth. The surface hardness of the different layers of cross-linked artificial teeth can be altered by daily disinfection in denture cleansers commonly indicated for removable dentures.

  18. Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.

    PubMed

    Farzin, M; Bahrani, F; Adelpour, E

    2013-09-01

    One of the most clinical challenging issues in prosthodontics is debonding of soft liners from the denture base. The aim of this study was to evaluate and compare tensile bond strength between soft liner and heat-cured acrylic resin when immersed in two different types of denture cleanser and distilled water, at different period of times. In this experimental in vivo study, 238 heat-cured acrylic blocks were made. A soft liner was embedded between the acrylic blocks. Samples were divided into four groups: 17 samples were in the control group and were not soaked in any solution .The remaining samples were divided into 3 groups (Distilled water, Calgon and Fittydent). Each group was then subdivided into two subcategories, regarding the immersion time variable; 15 and 45 minutes. All samples were placed in tension force and tensile bond strength was recorded with the testing machine. One- way ANOVA and Tucky HSD post-hoc test were adopted to analyze the yielded data (α> 0.05). Specimens which were immersed in two denture cleansers (Fittydent and Calgon) and in distilled water showed significant difference (p= 0.001) in bonding strength when compared to the control group. The subjects immersed in denture cleanser solutions and distilled water did not reveal any significant difference (p= 0.90). For all groups; most of the bonding failures (72%) were cohesive type. The effect of the denture cleansers and distilled water on the bond strength was not statistically different; however, the difference was significant between the immersed groups with the non-immersed group. Moreover, type of the denture cleanser did not show any effect on the tensile strength. The tensile strength increases with time of immersion.

  19. The effect of photo-activated glazes on the microhardness of acrylic baseplate resins.

    PubMed

    Emmanouil, J K; Kavouras, P; Kehagias, Th

    2002-01-01

    A comparative investigation of acrylic denture base surface microhardness, induced through glazing with different photo-activated liquids. Thermopolymerized acrylic resin Paladon 65 (Kulzer) was used for this study. The samples were mechanically thinned by silicon carbide grinding papers and finally, mechanically polished by alumina pastes. The samples were then glazed with Palaseal, Plaquit and Lightplast-Lack photo-activated liquids. Microhardness tests were carried out via a Zeiss optical microscope equipped with an Anton Paar microhardness tester fitted with a Knoop indenter. Microhardness testing performed on surfaces glazed by Plaquit, Lightplast-Lack, and Palaseal photo-activated liquids showed enhanced microhardness values compared to the mechanically polished acrylic resin denture base material. Comparative microhardness tests performed on acrylic base resin treated with photo-activated acrylic glazes showed that all increases the surface microhardness. The enhancement of surface microhardness of acrylic denture bases suggests that they are likely to resist wear during service.

  20. Mechanical properties of reinforced denture base resin: the effect of position and the number of woven glass fibers.

    PubMed

    Kanie, Takahito; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji

    2002-09-01

    This study examined the effects of the position and the number of woven glass fibers on the flexural strength, flexural modulus, and toughness of reinforced denture base resin. The woven glass fiber consisted of 1-4 laminated sheets. Chemical curing was used to polymerize three types of 4-mm-thick test specimens: fibers in compresrion, fibers in the center, and fibers in tension. Unreinforced specimens were produced as controls. A three-point flexural test was performed and the woven glass fiber content was calculated after the woven glass fiber was fired. The best results were obtained when the woven glass fiber was incorporated outside the base resin under tension, thereby increasing the flexural strength and flexural modulus. Furthermore, the denture base resin reinforced with woven glass fiber was made tougher by increasing the number of woven glass fibers incorporated into the portion under tension.

  1. Evaluation of Flexural Strength of Polymethyl Methacrylate modified with Silver Colloidal Nanoparticles subjected to Two Different Curing Cycles: An in vitro Study.

    PubMed

    Munikamaiah, Ranganath L; Jain, Saket K; Pal, Kapil S; Gaikwad, Ajay

    2018-03-01

    Silver colloidal nanoparticles have been incorporated into acrylic resins to induce antimicrobial properties. However, as additives, they can influence the mechanical properties of the final product. Mechanical properties are also dependent on different curing cycles. The aim of this study was to evaluate flexural strength of a denture base resin incorporated with different concentrations of silver colloidal nanoparticles subjected to two different curing cycles. Lucitone 199 denture base resin was used into which silver colloidal nanoparticles were incorporated at 0.5 and 5% by polymer mass. Specimens devoid of nanoparticles were used as controls. A total of 60 specimens were fabricated and divided into two groups. Each group was divided into three subgroups consisting of 10 specimens each. The specimens were fabricated according to American Dental Association (ADA) specification No. 12 and tested for flexural strength using universal testing machine. Silver colloidal nanoparticle incorporation at 0.5% concentration increased the mean flexural strength in both curing cycles by 7.5 and 4.4%, respectively, when compared with the control group. The study suggested that the mean flexural strength value of 0.5% silver colloidal nanoparticles in denture base resin was above the value of the control group both in short and long curing cycles, which makes it clinically suitable as a denture base material. However, at 5% concentration, the statistically significant amount of decrease in flexural strength compared with the value of control group both in short and long curing cycles gives it a questionable prognosis. The specimens incorporated with the antimicrobial agent 0.5% silver colloidal nanoparticles and processed by long curing cycles showed significant increase in its flexural strength compared with the control group, which makes it clinically suitable as a denture base material.

  2. Secreted Frizzled-related protein 1 (sFRP1) regulates spermatid adhesion in the testis via dephosphorylation of focal adhesion kinase and the nectin-3 adhesion protein complex

    PubMed Central

    Wong, Elissa W. P.; Lee, Will M.; Cheng, C. Yan

    2013-01-01

    Development of spermatozoa in adult mammalian testis during spermatogenesis involves extensive cell migration and differentiation. Spermatogonia that reside at the basal compartment of the seminiferous epithelium differentiate into more advanced germ cell types that migrate toward the apical compartment until elongated spermatids are released into the tubule lumen during spermiation. Apical ectoplasmic specialization (ES; a testis-specific anchoring junction) is the only cell junction that anchors and maintains the polarity of elongating/elongated spermatids (step 8–19 spermatids) in the epithelium. Little is known regarding the signaling pathways that trigger the disassembly of the apical ES at spermiation. Here, we show that secreted Frizzled-related protein 1 (sFRP1), a putative tumor suppressor gene that is frequently down-regulated in multiple carcinomas, is a crucial regulatory protein for spermiation. The expression of sFRP1 is tightly regulated in adult rat testis to control spermatid adhesion and sperm release at spermiation. Down-regulation of sFRP1 during testicular development was found to coincide with the onset of the first wave of spermiation at approximately age 45 d postpartum, implying that sFRP1 might be correlated with elongated spermatid adhesion conferred by the apical ES before spermiation. Indeed, administration of sFRP1 recombinant protein to the testis in vivo delayed spermiation, which was accompanied by down-regulation of phosphorylated (p)-focal adhesion kinase (FAK)-Tyr397 and retention of nectin-3 adhesion protein at the apical ES. To further investigate the functional relationship between p-FAK-Tyr397 and localization of nectin-3, we overexpressed sFRP1 using lentiviral vectors in the Sertoli-germ cell coculture system. Consistent with the in vivo findings, overexpression of sFRP1 induced down-regulation of p-FAK-Tyr397, leading to a decline in phosphorylation of nectin-3. In summary, this report highlights the critical role of sFRP1 in regulating spermiation via its effects on the FAK signaling and retention of nectin-3 adhesion complex at the apical ES.—Wong, E. W. P., Lee, W. M., Cheng, C. Y. Secreted Frizzled-related protein 1 (sFRP1) regulates spermatid adhesion in the testis via dephosphorylation of focal adhesion kinase and the nectin-3 adhesion protein complex. PMID:23073828

  3. Nanoindentation and surface roughness profilometry of poly methyl methacrylate denture base materials.

    PubMed

    Zafar, Muhammad Sohail; Ahmed, Naseer

    2014-01-01

    Polymers have a wide range of applications in dentistry. Poly methyl methacrylate (PMMA) is the most popular for making orthodontic retainers, dentures as well as synthetic teeth. Prior to clinical applications, the appliances are polished in the dental laboratory to achieve smooth, polished and comfortable surfaces. The objective of this study was to analyze the surface roughness profiles of PMMA dentures polished using two different approaches. In addition, the effects of ultrasonication and sandblasting were also evaluated on the fitting surface of PMMA dentures. This was an in vitro study using non-contact mode surface roughness profilometer and nano-indenter. Samples were polished using two different techniques (Standard and modified). Both cold cure and heat cure PMMA denture surfaces were evaluated for roughness, nanohardness and elastic modulus. The absolute hardness was recorded 297.72±19.04 MPa and 229.93±18.53 MPa for heat cured PMMA and cold cured PMMA. Manufactured acrylic teeth were harder (319.20±12.58 MPa) with an elastic modulus of (4.34±1.86 GPa). Modified polishing techniques (group 3) produced smoother surface. It was concluded that elastic moduli of acrylic tooth and heat cure PMMA is not very different. Surface treatments such as ultrasonication or sandblasting do not affect the roughness profiles of denture fitting surfaces.

  4. Alkaline Peroxides Versus Sodium Hypochlorite for Removing Denture Biofilm: a Crossover Randomized Trial.

    PubMed

    Peracini, Amanda; Regis, Rômulo Rocha; Souza, Raphael Freitas de; Pagnano, Valéria Oliveira; Silva, Cláudia Helena Lovato da; Paranhos, Helena de Freitas Oliveira

    2016-01-01

    This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.

  5. In vitro comparison of autoclave polymerization on the transverse strength of denture base resins.

    PubMed

    Durkan, Rukiye; Ozel, Mehmet Birol; Bağiş, Bora; Usanmaz, Ali

    2008-07-01

    The aim of this study was to determine the effect of autoclave polymerization on the transverse strength of denture base polymers. To this end, 30 rectangular test specimens were fabricated of two heat-polymerized denture base polymers. The test groups were: (I) control, i.e., conventional water bath to polymerize resins by heat at 100 degrees C for 30 minutes; (II) autoclave polymerization at 60 degrees C for 30 minutes followed by 130 degrees C for 10 minutes; and (III) autoclave polymerization at 60 degrees C for 30 minutes followed by 130 degrees C for 20 minutes. The specimens were tested with three-point bending test at a crosshead speed of 5 mm/min. It was revealed that the transverse strength of specimens increased with statistical significance when the autoclave was used for polymerization.

  6. [Experimental basis of a new material for the manufacture of bases dentures].

    PubMed

    Shturminskiĭ, V G

    2013-10-01

    The author studied the problem of improving the quality of prosthetic removable prostheses through the development of new basic material based on polypropylene copolymer. To this end, we examined the physical and chemical structure and hygienic properties of the produced material. The studies found that the developed material of polypropylene optimal solution for the partial plate denture bases, without flaws acrylic prosthesis and improves the properties of the previously used polypropylene plastics.

  7. Environmental stress-corrosion cracking of fiberglass: lessons learned from failures in the chemical industry.

    PubMed

    Myers, T J; Kytömaa, H K; Smith, T R

    2007-04-11

    Fiberglass reinforced plastic (FRP) composite materials are often used to construct tanks, piping, scrubbers, beams, grating, and other components for use in corrosive environments. While FRP typically offers superior and cost effective corrosion resistance relative to other construction materials, the glass fibers traditionally used to provide the structural strength of the FRP can be susceptible to attack by the corrosive environment. The structural integrity of traditional FRP components in corrosive environments is usually dependent on the integrity of a corrosion-resistant barrier, such as a resin-rich layer containing corrosion resistant glass fibers. Without adequate protection, FRP components can fail under loads well below their design by an environmental stress-corrosion cracking (ESCC) mechanism when simultaneously exposed to mechanical stress and a corrosive chemical environment. Failure of these components can result in significant releases of hazardous substances into plants and the environment. In this paper, we present two case studies where fiberglass components failed due to ESCC at small chemical manufacturing facilities. As is often typical, the small chemical manufacturing facilities relied largely on FRP component suppliers to determine materials appropriate for the specific process environment and to repair damaged in-service components. We discuss the lessons learned from these incidents and precautions companies should take when interfacing with suppliers and other parties during the specification, design, construction, and repair of FRP components in order to prevent similar failures and chemical releases from occurring in the future.

  8. [The reasons why 13 MK1 attachment were re-fabricated and some methods for improvement].

    PubMed

    Wu, Zhi-hong; Zhang, Xue-jun; Zhao, Jun

    2013-12-01

    To investigate the reasons why 13 MK1 attachment were re-fabricated and to suggest some improvement methods. Mechanics and denture production technology were reviewed in 13 cases with MK1 attachment denture to determine the causes of failure. In some cases, MK1 attachments were poorly designed, while in other cases problems were found during denture design and production process due to limited experiences at the initial stage. MK1 attachments were re-done based on the specific cause and the outcome was good after 1-1.5 years of follow-up. When using MK1 attachment, prosthodontists should be familiar with the characteristics and indications of MK1 attachment. Meanwhile, we should strengthen doctor-patient communication and follow up patients timely to improve the success rate of MK1 attached denture repair.

  9. Design Optimization of Hybrid FRP/RC Bridge

    NASA Astrophysics Data System (ADS)

    Papapetrou, Vasileios S.; Tamijani, Ali Y.; Brown, Jeff; Kim, Daewon

    2018-04-01

    The hybrid bridge consists of a Reinforced Concrete (RC) slab supported by U-shaped Fiber Reinforced Polymer (FRP) girders. Previous studies on similar hybrid bridges constructed in the United States and Europe seem to substantiate these hybrid designs for lightweight, high strength, and durable highway bridge construction. In the current study, computational and optimization analyses were carried out to investigate six composite material systems consisting of E-glass and carbon fibers. Optimization constraints are determined by stress, deflection and manufacturing requirements. Finite Element Analysis (FEA) and optimization software were utilized, and a framework was developed to run the complete analyses in an automated fashion. Prior to that, FEA validation of previous studies on similar U-shaped FRP girders that were constructed in Poland and Texas is presented. A finer optimization analysis is performed for the case of the Texas hybrid bridge. The optimization outcome of the hybrid FRP/RC bridge shows the appropriate composite material selection and cross-section geometry that satisfies all the applicable Limit States (LS) and, at the same time, results in the lightest design. Critical limit states show that shear stress criteria determine the optimum design for bridge spans less than 15.24 m and deflection criteria controls for longer spans. Increased side wall thickness can reduce maximum observed shear stresses, but leads to a high weight penalty. A taller cross-section and a thicker girder base can efficiently lower the observed deflections and normal stresses. Finally, substantial weight savings can be achieved by the optimization framework if base and side-wall thickness are treated as independent variables.

  10. Incorporation of Radio Frequency Identification Tag in Dentures to Facilitate Recognition and Forensic Human Identification

    PubMed Central

    Nuzzolese, E; Marcario, V; Di Vella, G

    2010-01-01

    Forensic identification using odontology is based on the comparison of ante-mortem and post mortem dental records. The insertion of a radio frequency identification (RFId) tag into dentures could be used as an aid to identify decomposed bodies, by storing personal identification data in a small transponder that can be radio-transmitted to a reader connected to a computer. A small passive, 12 x 2,1 mm, read-only RFId-tag was incorporated into the manufacture of three trial complete upper dentures and tested for a signal. The aim of this article is to demonstrate the feasibility of manufacturing such a dental prosthesis, the technical protocols for its implantation in the denture resin and its working principles. Future research and tests are required in order to verify human compatibility of the tagged denture and also to evaluate any potential deterioration in strength when subjected to high temperatures, or for damage resulting from everyday wear and tear. It should also be able to withstand the extreme conditions resulting from major accidents or mass disasters and procedures used to perform a forensic identification. PMID:20657641

  11. Occlusal force discrimination by denture patients.

    PubMed

    Pacer, R J; Bowman, D C

    1975-06-01

    A study was conducted on subjects with conventional dentures and with overlay dentures to compare their abilities to discriminate between occlusal forces. Perpendicular forces were applied to the dynamic center of the occlusal table of the mandibular denture. Each subject's ability to distinguish differences in values of force was observed and recorded. All subjects with dentures showed sensory threshold values close to those reported for natural teeth. A graphic plotting showed that the responses of subjects with overlay-type dentures were more closely correlated with the psychophysical law as expressed by Stevens as a power function. Since this phenomenon holds true for natural teeth, the overlay denture more closely resembles natural teeth in this type of sensory function than does the conventional denture. In addition to recognized advantages, such as preservation of the ridge and improved retention and stability, the overlay denture provides more typical sensory function than is provided by the conventional denture. This advantage should further motivate dentists and patients to consider the retention and utilization of at least two suitable teeth in an overlay-type denture service.

  12. On denture marking.

    PubMed

    Borrman, H I; DiZinno, J A; Wasén, J; René, N

    1999-06-01

    During the last decades in Sweden dentures have been permanently marked with a stainless steel metal band incorporated into the acrylic and containing the patient's birth date, a special number, and "S" for Sweden. The last recommendation issued by the National Board of Health and Welfare states that "the patients shall always be offered denture marking and be informed about the benefit thereof. Denture marking is not permitted if the patient refuses it". Requirements for denture markers have been that they should be biologically inert (when incorporated into the denture), not be expensive, be easy to inscribe, be possible to retrieve after an accident, and survive elevated temperatures for a reasonable time under normal circumstances. Although the frequency of edentulousness has decreased in recent years due to the improvement in oral health there remains a need to address the issue of marking of complete dentures, because there is a large variation in the oral status of populations in different countries. Given that only one marked denture can reveal the identity of a deceased person when all other methods fail to do so, makes it worthwhile. Furthermore, denture marking is important in long-term care facilities. We have investigated the issue of denture marking in Europe and in the United States. The results from the European survey show that denture marking is, to our knowledge regulated by law only in Sweden and Iceland. In the US denture marking is so far mandatory in 21 states while New York State requires dentures to be marked if the patient requests it and several other states impose the obligation to mark dentures on long-term care facilities. Since there is no international consensus regarding the issue of denture marking it is important to address it. A survey from the Nordic countries has shown that if denture marking was in general use, the contribution to the establishment of identity by forensic odontology in cases of fire would increase by about 10%. This means that about 25 more individuals could have been identified if their dentures were marked. Increased international collaboration is needed to solve the issue of denture marking for clinical and forensic purposes.

  13. Masticatory performance of complete denture wearers after using two adhesives: a crossover randomized clinical trial.

    PubMed

    de Oliveira Junior, Norberto Martins; Rodriguez, Larissa Santana; Mendoza Marin, Danny Omar; Paleari, André Gustavo; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-11-01

    Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (P<.001). No significant difference was found between the 2 denture adhesives evaluated. The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Patients' experiences with partial dentures: a qualitative study.

    PubMed

    Smith, Patricia A; Entwistle, Vikki A; Nuttall, Nigel

    2005-12-01

    The aim of the study was to gain insight into people's experiences of being given and using partial dentures. In-depth semi-structured interviews were carried out with 23 people of varied age, social background and denture wearing experience in Tayside, Scotland. Participants were encouraged to discuss how they came to have partial dentures, their day-to-day denture use and their interactions with dentists. The interview data were systematically coded using key theme headings, and summary charts were constructed to facilitate analysis. The initial decision that a partial denture was needed was generally difficult to accept. People perceived the main benefits of partial dentures to be improved appearance and confidence, but experienced a variety of difficulties with their dentures and often coped with these by only wearing them on social occasions. Participants had not always told their dentists about the difficulties they experienced. Barriers to seeking help with denture problems included financial constraints, previous experience of rushed appointments or poor communication from dentists and a perceived lack of entitlement to help when partial dentures were issued free. Partial dentures can be difficult to cope with. People experience a range of difficulties in wearing them, not all of which have been discussed with dentists. Informative and supportive communication when partial dentures are first needed, and subsequently, can improve the quality of patients' experiences and may help promote effective use and appropriate help-seeking by partial denture wearers.

  15. Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases.

    PubMed

    Consani, Rafael Leonardo Xediek; Domitti, Saide Sarckis; Consani, Simonides

    2002-09-01

    The pressure of final closure may be released when the flask is removed from the mechanical or pneumatic press and placed in the spring clamp. This release in pressure may result in dimensional changes that distort the denture base. The purpose of this study was to investigate differences between the dimensional stability of standardized simulated denture bases processed by traditional moist heat-polymerization and those processed by use of a new tension system. A metal master die was fabricated to simulate an edentulous maxillary arch without irregularities in the alveolar ridge walls. A silicone mold of this metallic die was prepared, and 40 stone casts were formed from the mold with type III dental stone. The casts were randomly assigned to 4 test groups (A-D) of 10 specimens each. A uniform denture base pattern was made on each stone cast with a 1.5-mm thickness of base-plate wax, measured with a caliper. The patterns were invested for traditional hot water processing. A polymethyl methacrylate dough was prepared and packed for processing. The flasks in groups A and B were closed with the traditional pressure technique and placed in spring clamps after final closure. The flasks in groups C and D were pressed between the metallic plates of the new tension system after the final closure. The group A and C flasks were immediately immersed in the water processing unit at room temperature (25 degrees +/- 2 degrees C). The unit was programmed to raise the temperature to 74 degrees C over 1 hour, and then maintained the temperature at 74 degrees C for 8 hours. The group B and D flasks were bench stored at room temperature (25 degrees +/- 2 degrees C) for 6 hours and were then subjected to the same moist heat polymerization conditions as groups A and C. All processed dentures were bench cooled for 3 hours. After recovery from the flasks, the base-cast sets were transversally sectioned into 3 parts (corresponding to 3 zones): (1) distal of the canines, (2) mesial of the first molars, and (3) mesial of the posterior palate). These areas had been previously established and standardized by use of a pattern denture in the sawing device to determine the sections in each base-cast set. Base-cast gaps were measured at 5 predetermined points on each section with an optical micrometer that had a tolerance of 0.001 mm. Collected data were analyzed with analysis of variance and Tukey's test. Denture bases processed with the new tension system exhibited significantly better base adaptation than those processed with traditional acrylic resin packing. Immediately after polymerization (Groups A and C), mean dimensional change values were 0.213 +/- 0.055 mm for the traditional packing technique and 0.173 +/- 0.050 mm for new tension system. After delayed polymerization (Groups B and D), the values were 0.216 +/- 0.074 mm for the traditional packing technique and 0.164 +/- 0.032 mm for new tension system. With both techniques, dimensional changes in the posterior palatal zone were greater (conventional = 0.286 +/- 0.038 mm; new system = 0.214 +/- 0.024 mm) than those elsewhere on the base-cast set. Within the limitations of this study, the new tension packing system was associated with decreased dimensional changes in the simulated maxillary denture bases processed with heat-polymerization.

  16. Candida albicans biofilm heterogeneity does not influence denture stomatitis but strongly influences denture cleansing capacity.

    PubMed

    O'Donnell, Lindsay E; Alalwan, Hasanain K A; Kean, Ryan; Calvert, Gareth; Nile, Christopher J; Lappin, David F; Robertson, Douglas; Williams, Craig; Ramage, Gordon; Sherry, Leighann

    2017-01-01

    Approximately 20  % of the UK population wear some form of denture prosthesis, resulting in denture stomatitis in half of these individuals. Candida albicans is primarily attributed as the causative agent, due to its biofilm -forming ability. Recently, there has been increasing evidence of C. albicans biofilm heterogeneity and the negative impact it can have clinically; however, this phenomenon has yet to be studied in relation to denture isolates. The aims of this study were to evaluate C. albicans biofilm formation of clinical denture isolates in a denture environment and to assess antimicrobial activity of common denture cleansers against these tenacious communities. C. albicans isolated from dentures of healthy and diseased individuals was quantified using real-time PCR and biofilm biomass assessed using crystal violet. Biofilm development on the denture substratum poly(methyl methacrylate), Molloplast B and Ufi-gel was determined. Biofilm formation was assessed using metabolic and biomass stains, following treatment with denture hygiene products. Although C. albicans was detected in greater quantities in diseased individuals, it was not associated with increased biofilm biomass. Denture substrata were shown to influence biofilm biomass, with poly(methyl methacrylate) providing the most suitable environment for C. albicans to reside. Of all denture hygiene products tested, Milton had the most effective antimicrobial activity, reducing biofilm biomass and viability the greatest. Overall, our results highlight the complex nature of denture- related disease, and disease development cannot always be attributed to a sole cause. It is the distinct combination of various factors that ultimately determines the pathogenic outcome.

  17. A phenomenological intra-laminar plasticity model for FRP composite materials

    NASA Astrophysics Data System (ADS)

    Zhou, Yinhua; Hou, Chi; Wang, Wenzhi; Zhao, Meiying; Wan, Xiaopeng

    2015-07-01

    The nonlinearity of fibre-reinforced polymer (FRP) composites have significant effects on the analysis of composite structures. This article proposes a phenomenological intralaminar plasticity model to represent the nonlinearity of FRP composite materials. Based on the model presented by Ladeveze et al., the plastic potential and hardening functions are improved to give a more rational description of phenomenological nonlinearity behavior. A four-parameter hardening model is built to capture important features of the hardening curve and consequently gives the good matching of the experiments. Within the frame of plasticity theory, the detailed constitutive model, the numerical algorithm and the derivation of the tangent stiffness matrix are presented in this study to improve model robustness. This phenomenological model achieved excellent agreement between the experimental and simulation results in element scale respectively for glass fibre-reinforced polymer (GFRP) and carbon fibre-reinforced polymer (CFRP). Moreover, the model is capable of simulating the nonlinear phenomenon of laminates, and good agreement is achieved in nearly all cases.

  18. Comparative Effect of Different Polymerization Techniques on the Flexural and Surface Properties of Acrylic Denture Bases.

    PubMed

    Gad, Mohammed M; Fouda, Shaimaa M; ArRejaie, Aws S; Al-Thobity, Ahmad M

    2017-05-22

    Polymerization techniques have been modified to improve physical and mechanical properties of polymethylmethacrylate (PMMA) denture base, as have the laboratory procedures that facilitate denture construction techniques. The purpose of the present study was to investigate the effect of autoclave polymerization on flexural strength, elastic modulus, surface roughness, and the hardness of PMMA denture base resins. Major Base and Vertex Implacryl heat-polymerized acrylic resins were used to fabricate 180 specimens. According to the polymerization technique, tested groups were divided into: group I (water-bath polymerization), group II (short autoclave polymerization cycle, 60°C for 30 minutes, then 130°C for 10 minutes), and group III (long autoclave polymerization cycle, 60°C for 30 minutes, then 130°C for 20 minutes). Each group was divided into two subgroups based on the materials used. Flexural strength and elastic modulus were determined by a three-point bending test. Surface roughness and hardness were evaluated with a profilometer and Vickers hardness (VH) test, respectively. One-way ANOVA and the Tukey-Kramer multiple-comparison test were used for results analysis, which were statistically significant at p ≤ 0.05. Autoclave polymerization showed a significant increase in flexural strength and hardness of the two resins (p < 0.05). The elastic modulus showed a significant increase in the major base resin, while a significant decrease was seen for Vertex Implacryl in all groups (p < 0.05); however, there was no significant difference in surface roughness between autoclave polymerization and water-bath polymerization (p > 0.05). Autoclave polymerization significantly increased the flexural properties and hardness of PMMA denture bases, while the surface roughness was within acceptable clinical limits. For a long autoclave polymerization cycle, it could be used as an alternative to water-bath polymerization. © 2017 by the American College of Prosthodontists.

  19. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    PubMed

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P < .05. The clinicians' overall mean rating of the clinical quality of the dentures was 91.5% (standard deviation 6.27%). The stability of the mandibular overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.

  20. The concept of sustainable prefab modular housing made of natural fiber reinforced polymer (NFRP)

    NASA Astrophysics Data System (ADS)

    Setyowati, E.; Pandelaki, E. E.

    2018-03-01

    This research aims to formulate the concept of public housing based on research results on natural fiber reinforced polymer (FRP) material which has been done in the road map of research. Research output is the public housing design and specifications of FRP made of water hyacinths and coconut fiber. Method used is descriptive review of the concept based on references and material test which consists of density, water absorption, modulus of rupture (MOR), tensile strength, absorption coefficient and Sound Transmission Loss (STL). The entire tests of material were carried out in the laboratory of materials and construction, while the acoustic tests carried out using the impedance tubes method. The test results concluded that the FRP material may have a density between 0.2481 – 0.2777 g/cm3, the absorption coefficient is average of 0.450 – 0.900, the Modulus of Elasticity is between 4061 – 15193 kg/cm2, while the average of sound transmission loss is 52 – 59 dB. Furthermore, that the concept of public housing must be able to be the embryo of the concept of environment-friendly and low emissions housing.

  1. The effect of cleaning substances on the surface of denture base material.

    PubMed

    Žilinskas, Juozas; Junevičius, Jonas; Česaitis, Kęstutis; Junevičiūtė, Gabrielė

    2013-12-11

    The aim of this study was to evaluate the effect of substances used for hygienic cleaning of dentures on the surface of the denture base material. Meliodent Heat Cure (Heraeus-Kulzer, Germany) heat-polymerized acrylic resin was used to produce plates with all the characteristics of removable denture bases (subsequently, "plates"). Oral-B Complete toothbrushes of various brush head types were fixed to a device that imitated tooth brushing movements; table salt and baking soda (frequently used by patients to improve tooth brushing results), toothpaste ("Colgate Total"), and water were also applied. Changes in plate surfaces were monitored by measuring surface reflection alterations on spectrometry. Measurements were conducted before the cleaning and at 2 and 6 hours after cleaning. No statistically significant differences were found between the 3 test series. All 3 plates used in the study underwent statistically significant (p<0.05 changed)--the reflection became poorer. The plates were most affected by the medium-bristle toothbrush with baking soda--the total reflection reduction was 4.82 ± 0.1%; among toothbrushes with toothpaste, the hard-type toothbrush had the greatest reflection-reducing effect--4.6 ± 0.05%, while the toothbrush with table salt inflicted the least damage (3.5 ± 0.16%) due to the presence of rounded crystals between the bristles and the resin surface. Toothbrushes with water had a uniform negative effect on the plate surface - 3.8 9 ± 0.07%. All substances used by the patients caused surface abrasion of the denture base material, which reduced the reflection; a hard toothbrush with toothpaste had the greatest abrasive effect, while soft toothbrushes inflicted the least damage.

  2. Surface discharge related properties of fiberglass reinforced plastic insulator for use in neutral beam injector of JT-60U.

    PubMed

    Yamano, Y; Takahashi, M; Kobayashi, S; Hanada, M; Ikeda, Y

    2008-02-01

    Neutral beam injection (NBI) used for JT-60U is required to generate negative ions of 500 keV energies. To produce such high-energy ions, three-stage electrostatic accelerators consisting of three insulator rings made of fiberglass reinforced plastic (FRP) are applied. The surface discharges along FRP insulators are one of the most serious problems in the development of NBI. To increase the hold-off voltage against surface flashover events, it is necessary to investigate the FRP insulator properties related to surface discharges in vacuum. This paper describes surface flashover characteristics for FRP and alumina samples under vacuum condition. The results show that the fold-off voltages for FRP samples are inferior to those of alumina ceramics. In addition, measurement results of surface resistivity and volume resistivity under vacuum and atmospheric conditions, secondary electron emission characteristics, and cathodoluminescence under some keV electron beam irradiation are also reported. These are important parameters to analyze surface discharge of insulators in vacuum.

  3. Surface discharge related properties of fiberglass reinforced plastic insulator for use in neutral beam injector of JT-60Ua)

    NASA Astrophysics Data System (ADS)

    Yamano, Y.; Takahashi, M.; Kobayashi, S.; Hanada, M.; Ikeda, Y.

    2008-02-01

    Neutral beam injection (NBI) used for JT-60U is required to generate negative ions of 500keV energies. To produce such high-energy ions, three-stage electrostatic accelerators consisting of three insulator rings made of fiberglass reinforced plastic (FRP) are applied. The surface discharges along FRP insulators are one of the most serious problems in the development of NBI. To increase the hold-off voltage against surface flashover events, it is necessary to investigate the FRP insulator properties related to surface discharges in vacuum. This paper describes surface flashover characteristics for FRP and alumina samples under vacuum condition. The results show that the fold-off voltages for FRP samples are inferior to those of alumina ceramics. In addition, measurement results of surface resistivity and volume resistivity under vacuum and atmospheric conditions, secondary electron emission characteristics, and cathodoluminescence under some keV electron beam irradiation are also reported. These are important parameters to analyze surface discharge of insulators in vacuum.

  4. Push-out tests and evaluation of FRP perfobond rib shear connectors performance

    NASA Astrophysics Data System (ADS)

    Kolpasky, Ludvik; Ryjacek, Pavel

    2017-09-01

    The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.

  5. Effect of long-time immersion of soft denture liners in water on viscoelastic properties.

    PubMed

    Iwasaki, Naohiko; Yamaki, Chisato; Takahashi, Hidekazu; Oki, Meiko; Suzuki, Tetsuya

    2017-09-26

    Aim of this study was to investigate the effect of long-time immersion of soft denture liners in 37°C water on viscoelastic properties. Six silicone-based and two acrylic resin-based soft denture liners were selected. Cylindrical specimens were stored in distilled water at 37°C for 6 months. Viscoelastic properties, which were instantaneous and delayed elastic displacements, viscous flow, and residual displacement, were determined using a creep meter, and analyzed with 2-way analysis of variance and Tukey's comparison (α=0.05). Viscoelastic properties and their time-dependent changes were varied among materials examined. The observed viscoelastic properties of three from six silicone-based liners did not significantly change after 6-month immersion, but those of two acrylic resin-based liners significantly changed with the increase of immersion time. However, the sum of initial instantaneous elastic displacement and delayed elastic displacement of two acrylic resin-based liners during 6-month immersion changed less than 10%, which might indicate clinically sufficient elastic performance.

  6. Diagnosis and treatment of orofacial pain in a patient with unserviceable complete dentures: A clinical report.

    PubMed

    Selecman, Audrey M; Ahuja, Swati A

    2018-02-08

    An ill-fitting complete denture has the potential to create pain and discomfort as well as conceal or confound the diagnosis of other primary sources of orofacial pain such as trigeminal neuralgia. Guidelines of the American Academy of Orofacial Pain offer an evidence-based approach for the assessment, diagnosis, and management of orofacial pain. A complete and accurate differential diagnosis is paramount to the success of treatment as well as to the circumvention of unnecessary therapy. The purpose of this clinical report was to emphasize an evidence-based approach to the diagnosis and treatment of orofacial pain in a patient with edentulism and a history of prolonged denture wear. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques.

    PubMed

    Zaparolli, Danilo; Peixoto, Raniel Fernandes; Pupim, Denise; Macedo, Ana Paula; Toniollo, Marcelo Bighetti; Mattos, Maria da Glória Chiarello de

    2017-12-01

    To compare the stress distribution of mandibular full dentures supported with implants according to the bar materials and manufacturing techniques using a qualitative photoelastic analysis. An acrylic master model simulating the mandibular arch was fabricated with four Morse taper implant analogs of 4.5×6mm. Four different bars were manufactured according to different material and techniques: fiber-reinforced resin (G1, Trinia, CAD/CAM), commercially pure titanium (G2, cpTi, CAD/CAM), cobalt‑chromium (G3, Co-Cr, CAD/CAM) and cobalt‑chromium (G4, Co-Cr, conventional cast). Standard clinical and laboratory procedures were used by an experienced dental technician to fabricate 4 mandibular implant-supported dentures. The photoelastic model was created based on the acrylic master model. A load simulation (150N) was performed in total occlusion against the antagonist. Dentures with fiber-reinforced resin bar (G1) exhibited better stress distribution. Dentures with machined Co-Cr bar (G3) exhibited the worst standard of stress distribution, with an overload on the distal part of the posteriors implants, followed by dentures with cast Co-Cr bar (G4) and machined cpTi bar (G2). The fiber-reinforced resin bar exhibited an adequate stress distribution and can serve as a viable alternative for oral rehabilitation with mandibular full dentures supported with implants. Moreover, the use of the G1 group offered advantages including reduced weight and less possible overload to the implants components, leading to the preservation of the support structure. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up.

    PubMed

    Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M

    2016-01-01

    In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan-Meier method. None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study.

  9. Multi-layered sensor yarns for in situ monitoring of textile reinforced composites

    NASA Astrophysics Data System (ADS)

    Haentzsche, E.; Onggar, T.; Nocke, A.; Hund, R. D.; Cherif, Ch

    2017-10-01

    In this contribution, the characteristic of yarns that have intrinsically conductivity as well as such with coaxial conductive coatings acting as in situ strain sensors are described. The objective of the based research projects is the real-time in situ sensing of both global stresses acting on fibre reinforced plastic (FRP) components and the detection of resulted local microscopic damages due to creep, delamination and micro-cracks in the fibre-matrix interphase of glass fibre (GFRP) and carbon fibre (CFRP) composites. Sensor materials similar to the particular FRP and its mechanical behaviour have been chosen. In the first approach, GF- and aramid-based sensor yarns have been developed with multiple tailored silver layer coating system capable to distinguish multiple scaled damage mechanism due to these effects globally and locally. The second approach bases on the piezoresistive effect of CF rovings for their usage as in situ strain sensors. In the next step, suitable fibre and polymer film-based cleading have been tested and evaluated, granting sufficient electrical isolation to avoid shortcircuits between the conductive sensor layers itself or between the sensor and intrinsically conductive CFRP respectively. Initially, the sensor performance of global strain measurement, means the accumulated strain along the integration length of the sensor yarn, has been evaluated during tensile stressing of FRP with integrated suchlike functionalised sensor yarns.

  10. Blast Design of Reinforced Concrete and Masonry Components Retrofitted with FRP

    DTIC Science & Technology

    2010-07-01

    1 BLAST DESIGN OF REINFORCED CONCRETE AND MASONRY COMPONENTS RETROFITTED WITH FRP Marlon L. Bazan, Ph.D. and Charles J. Oswald, P.E., Ph.D...as an alternative to traditional methods for strengthening and retrofitting concrete and masonry structures to resist blast loads. The development...and experimental validation of a methodology for modeling the response of blast loaded concrete and masonry structural components retrofitted with FRP

  11. The electrostatic properties of Fiber-Reinforced-Plastics double wall underground storage gasoline tanks

    NASA Astrophysics Data System (ADS)

    Li, Yipeng; Liu, Quanzhen; Meng, He; Sun, Lifu; Zhang, Yunpeng

    2013-03-01

    At present Fiber Reinforced Plastics (FRP) double wall underground storage gasoline tanks are wildly used. An FRP product with a resistance of more than 1011 Ω is a static non-conductor, so it is difficult for the static electricity in the FRP product to decay into the earth. In this paper an experimental system was built to simulate an automobile gasoline filling station. Some electrostatic parameters of the gasoline, including volume charge density, were tested when gasoline was unloaded into a FRP double wall underground storage tank. Measurements were taken to make sure the volume charge density in the oil-outlet was similar to the volume charge density in the tank. In most cases the volume charge density of the gasoline was more than 22.7 μC m-3, which is likely to cause electrostatic discharge in FRP double wall underground storage gasoline tanks. On the other hand, it would be hard to ignite the vapor by electrostatic discharge since the vapor pressure in the tanks is over the explosion limit. But when the tank is repaired or re-used, the operators must pay attention to the static electricity and some measurements should be taken to avoid electrostatic accident. Besides the relaxation time of charge in the FRP double wall gasoline storage tanks should be longer.

  12. Increased expression of the WNT antagonist sFRP-1 in glaucoma elevates intraocular pressure

    PubMed Central

    Wang, Wan-Heng; McNatt, Loretta G.; Pang, Iok-Hou; Millar, J. Cameron; Hellberg, Peggy E.; Hellberg, Mark H.; Steely, H. Thomas; Rubin, Jeffrey S.; Fingert, John H.; Sheffield, Val C.; Stone, Edwin M.; Clark, Abbot F.

    2008-01-01

    Elevated intraocular pressure (IOP) is the principal risk factor for glaucoma and results from excessive impedance of the fluid outflow from the eye. This abnormality likely originates from outflow pathway tissues such as the trabecular meshwork (TM), but the associated molecular etiology is poorly understood. We discovered what we believe to be a novel role for secreted frizzled-related protein-1 (sFRP-1), an antagonist of Wnt signaling, in regulating IOP. sFRP1 was overexpressed in human glaucomatous TM cells. Genes involved in the Wnt signaling pathway were expressed in cultured TM cells and human TM tissues. Addition of recombinant sFRP-1 to ex vivo perfusion-cultured human eyes decreased outflow facility, concomitant with reduced levels of β-catenin, the Wnt signaling mediator, in the TM. Intravitreal injection of an adenoviral vector encoding sFRP1 in mice produced a titer-dependent increase in IOP. Five days after vector injection, IOP increased 2 fold, which was significantly reduced by topical ocular administration of an inhibitor of a downstream suppressor of Wnt signaling. Thus, these data indicate that increased expression of sFRP1 in the TM appears to be responsible for elevated IOP in glaucoma and restoring Wnt signaling in the TM may be a novel disease intervention strategy for treating glaucoma. PMID:18274669

  13. Does the nature of the definitive impression material influence the outcome of (mandibular) complete dentures?

    PubMed

    McCord, J Fraser; McNally, Lisa M; Smith, Philip W; Grey, Nicholas J A

    2005-09-01

    The effects of impression materials on the outcome of complete dentures are poorly understood. This double-blind cross-over randomized controlled trial investigated eleven adult edentulous patients. Each received a maxillary denture and three mandibular dentures (which differed only in the three materials used to record the definitive impressions). The three mandibular dentures were given in a random order. Patients' opinions of each denture were recorded using a Linear Analogue Scale. There was a statistically-significant difference between the outcome of the dentures constructed when zinc-oxide eugenol was used, this material being least favoured (p < 0.001). It would therefore appear that care should be exercised when selecting impression materials when constructing mandibular complete dentures.

  14. Management of bruxism-induced complications in removable partial denture wearers using specially designed dentures: a clinical report.

    PubMed

    Baba, Kazuyoshi; Aridome, Kumiko; Pallegama, Ranjith Wasantha

    2008-01-01

    In patients with a limited number of remaining teeth, bruxism force can be destructive for both the remaining teeth and periodontal structures. This paper reports the successful management of four such patients with severe sleep bruxism, using conventional removable partial dentures and specially designed, splint-like removable partial dentures called a night denture. The night denture was fabricated in two different designs, which depended upon the pattern of the remaining tooth contacts. The patients were followed up for 2-6 years using a night denture in either of the two designs. Within the limitations of these four reports of clinical cases, the night denture appeared to be effective in managing the problems related to sleep bruxism.

  15. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    PubMed

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  16. Digital Denture Fabrication in Pre- and Postdoctoral Education: A Survey of U.S. Dental Schools.

    PubMed

    Fernandez, Monica A; Nimmo, Arthur; Behar-Horenstein, Linda S

    2016-01-01

    To survey chairs of prosthodontics or restorative departments and program directors of postdoctoral prosthodontic programs in the United States regarding digital denture fabrication. The key objectives of the survey were to identify the current trends in complete denture fabrication using CAD/CAM technology and to determine how and to what extent this technique is taught and used in U.S. pre- and postdoctoral prosthodontic programs. An invitation to participate in an online survey was sent to 52 prosthodontics/restorative chairs of U.S. dental schools and to all of the 50 program directors of postdoctoral prosthodontics programs. A version of the survey with the same questions was sent to a national sample of prosthodontics/restorative chairs and program directors of postdoctoral prosthodontics. The 20-item survey took approximately 15 minutes to complete. Dependent samples paired t-test was run on items that were the same in both surveys. The response rate for the survey was 63% for department chairs and 44% for program directors. All respondents with the exception of one department chair were aware of CAD/CAM technology used for denture fabrication. More than half of the program directors (52.4%) compared to 12.1% of chairs have incorporated some aspects of CAD/CAM denture fabrication technology into their curriculum. When asked if the fabrication cost prevented introducing this technology in the predoctoral/postdoctoral curriculum, 52.4% of the department chairs affirmed this response compared to 12.1% of the program directors. There was a significant difference between groups when asked if they had incorporated the CAD/CAM denture fabrication technique into the postgraduate/predoctoral curriculum. Department chairs reported less usage of CAD/CAM technology. Only 12.1% of department chairs reported using some aspects of CAD/CAM technology in the predoctoral curriculum compared to 52.4% in the postdoctoral curriculum (F = 13.528, p ≤ 0.001). While this technology is used in four predoctoral clinics, none of the chairs reported including CAD/CAM denture fabrication in their preclinical complete denture courses. For the schools using the technology, 33.3% of postdoctoral and 30.3% of predoctoral programs use it to make a denture with a try-in step; however, 19% of the postdoctoral and 18.2% of predoctoral programs process the dentures without a try-in appointment. Slightly less than half (42.9%) of graduate programs are using the technology to make just the denture bases. Only a small proportion (10% or less) of the total number of dentures processed in post- and predoctoral programs are made using CAD/CAM technology. The proportion of postdoctoral programs that process cases using CAD/CAM technology was significantly higher than in predoctoral programs (F = 5.106, p ≤ 0.028). Many schools indicated that they are in a "trial phase" to evaluate the technique, especially at the predoctoral level. Also, 19% (n = 4) of postdoctoral and 15.2% (n = 5) of predoctoral respondents have created continuing education courses. Of postdoctoral programs, 38.1% (n = 8) plan to introduce this technology at some point in the near future (next 1 to 4 years); 27.3% of predoctoral programs plan to as well. All program directors and department chairs who participated in the survey are aware of this technology with the exception of one department chair. More than half of the program directors reported that they have incorporated this technology in their curricula compared to only 12% of department chairs. Currently, only 10% or less of complete denture cases are processed using the CAD/CAM technology, at either the post- or predoctoral levels. Both groups reported that the main use of this technology is for the fabrication of denture bases and for processing dentures including the try-in step. The majority of respondents in both groups indicated they plan to add digital denture fabrication into their curricula within the next 1 to 4 years. © 2015 by the American College of Prosthodontists.

  17. Comparison of using different bridge prosthetic designs for partial defect restoration through mathematical modeling.

    PubMed

    Styranivska, Oksana; Kliuchkovska, Nataliia; Mykyyevych, Nataliya

    2017-01-01

    To analyze the stress-strain states of bone and abutment teeth during the use of different prosthetic designs of fixed partial dentures with the use of relevant mathematical modeling principles. The use of Comsol Multiphysics 3.5 (Comsol AB, Sweden) software during the mathematical modeling of stress-strain states provided numerical data for analytical interpretation in three different clinical scenarios with fixed dentures and different abutment teeth and demountable prosthetic denture with the saddle-shaped intermediate part. Microsoft Excel Software (Microsoft Office 2017) helped to evaluate absolute mistakes of stress and strain parameters of each abutment tooth during three modeled scenarios and normal condition and to summarize data into the forms of tables. In comparison with the fixed prosthetic denture supported by the canine, first premolar, and third molar, stresses at the same abutment teeth with the use of demountable denture with the saddle-shaped intermediate part decreased: at the mesial abutment tooth by 2.8 times, at distal crown by 6.1 times, and at the intermediate part by 11.1 times, respectively, the deformation level decreased by 3.1, 1.9, and 1.4 times at each area. The methods of mathematical modeling proved that complications during the use of fixed partial dentures based on the overload effect of the abutment teeth and caused by the deformation process inside the intermediate section of prosthetic construction.

  18. Speech intelligibility enhancement after maxillary denture treatment and its impact on quality of life.

    PubMed

    Knipfer, Christian; Riemann, Max; Bocklet, Tobias; Noeth, Elmar; Schuster, Maria; Sokol, Biljana; Eitner, Stephan; Nkenke, Emeka; Stelzle, Florian

    2014-01-01

    Tooth loss and its prosthetic rehabilitation significantly affect speech intelligibility. However, little is known about the influence of speech deficiencies on oral health-related quality of life (OHRQoL). The aim of this study was to investigate whether speech intelligibility enhancement through prosthetic rehabilitation significantly influences OHRQoL in patients wearing complete maxillary dentures. Speech intelligibility by means of an automatic speech recognition system (ASR) was prospectively evaluated and compared with subjectively assessed Oral Health Impact Profile (OHIP) scores. Speech was recorded in 28 edentulous patients 1 week prior to the fabrication of new complete maxillary dentures and 6 months thereafter. Speech intelligibility was computed based on the word accuracy (WA) by means of an ASR and compared with a matched control group. One week before and 6 months after rehabilitation, patients assessed themselves for OHRQoL. Speech intelligibility improved significantly after 6 months. Subjects reported a significantly higher OHRQoL after maxillary rehabilitation with complete dentures. No significant correlation was found between the OHIP sum score or its subscales to the WA. Speech intelligibility enhancement achieved through the fabrication of new complete maxillary dentures might not be in the forefront of the patients' perception of their quality of life. For the improvement of OHRQoL in patients wearing complete maxillary dentures, food intake and mastication as well as freedom from pain play a more prominent role.

  19. Biomechanical factors related to occlusal load transfer in removable complete dentures.

    PubMed

    Żmudzki, Jarosław; Chladek, Grzegorz; Kasperski, Jacek

    2015-08-01

    Owing to economic conditions, removable dentures remain popular despite the discomfort and reduced chewing efficiency experienced by most denture wearers. However, there is little evidence to confirm that the level of mucosal load exceeds the pressure pain threshold. This discrepancy stimulated us to review the current state of knowledge on the biomechanics of mastication with complete removable dentures. The loading beneath dentures was analyzed in the context of denture foundation characteristics, salivary lubrication, occlusal forces, and the biomechanics of mastication. The analysis revealed that the interpretation of data collected in vivo is hindered due to the simultaneous overlapping effects of many variables. In turn, problems with determining the pressure beneath a denture and analyzing frictional processes constitute principal limitations of in vitro model studies. Predefined conditions of finite element method simulations should include the effects of oblique mastication forces, simultaneous detachment and sliding of the denture on its foundation, and the stabilizing role of balancing contacts. This review establishes that previous investigations may have failed because of their unsubstantiated assumption that, in a well-working balanced occlusion, force is only exerted perpendicular to the occlusal plane, allowing the denture to sit firmly on its foundation. Recent improvements in the simulation of realistic biomechanical denture behavior raise the possibility of assessing the effects of denture design on the pressures and slides beneath the denture.

  20. Assessment of Hygiene Habits in Acrylic Denture Wearers: a Cross-sectional Study

    PubMed Central

    Aoun, Georges; Gerges, Elie

    2017-01-01

    Objectives: To assess the denture hygiene habits in a population of Lebanese denture wearers. Materials and Methods: One hundred and thirty-two (132) patients [71 women (53.8%) and 61 men (46.2%)] wearing their acrylic dentures for more than two years were included in this study. The hygiene methods related to their dentures were evaluated and the data obtained were analyzed statistically using the IBM® SPSS® statistics 20.0 (USA) statistical package. Results: Regardless of the cleaning technique, the big majority of our participants [123 out of 132 (93.1%)] cleaned their dentures daily. The two mostly used denture cleaning techniques were rinsing with tap water (34.1%) and brushing with toothpaste (31.8%). Nearly half of our patients (45.5%) soaked their dentures during the night; most of them with cleansing tablets dissolved in water (28.8%). Conclusions: Within the limitations of our study, it was concluded that in a sample of Lebanese population surveyed about denture hygiene habits, the daily frequency of denture cleaning is satisfactory, but the techniques and products used were self-estimated and, consequently, not sufficient. PMID:29109670

  1. An investigation into denture loss in hospitals in Kent, Surrey and Sussex.

    PubMed

    Mann, J; Doshi, M

    2017-08-25

    Background The loss of dentures for inpatients can have a detrimental effect on their well-being. Self-respect and dignity become compromised along with their ability to eat meals and communicate clearly, and long-term recovery.Aim This investigation aimed to identify the reported number of dentures lost in hospitals and the financial reimbursements given by trusts to replace them.Method Information on reported denture loss and reimbursement was collected in 12 trusts throughout Kent, Surrey and Sussex.Results Eleven out of 12 trusts returned data about how many dentures were lost in their hospitals, between them 695 dentures were reported lost over five years (2011-16). Seven trusts reported financial reimbursements for dentures losses; results showed £357,672 was reimbursed over six years (2010-16), the highest amount reimbursed for a single denture was £2,200.Conclusion The results indicate that denture loss is a problem in hospitals that contributes to the financial burden for the NHS. Consideration needs to be given by hospitals to find ways to reduce the number of dentures lost every year.

  2. An operational system for the assimilation of satellite information on wild-land fires for the needs of air quality modelling and forecasting

    NASA Astrophysics Data System (ADS)

    Sofiev, M.; Vankevich, R.; Lanne, M.; Prank, M.; Petukhov, V.; Ermakova, T.; Kukkonen, J.

    2009-03-01

    This paper investigates a potential of two remotely sensed wild-land fire characteristics: 4-μm Brightness Temperature Anomaly (TA) and Fire Radiative Power (FRP) for the needs of operational chemical transport modelling and the short-term forecasting of the atmospheric composition and air quality. Two treatments of the TA and FRP data are presented and a methodology for evaluating the emission fluxes is described. The method does not contain a complicated analysis of vegetation state, fuel load, burning efficiency and related factors, which are comparatively uncertain but inevitably involved in approaches based on burnt-area scars or similar products. The core of the current methodology is based on the empirical emission factors that have been derived from the analysis of several fire episodes in Europe (28 April-5 May 2006, 15-25 August 2006, August 2008 etc.). These episodes were characterised by: (i) well-identified FRP and TA values, and (ii) available independent observations of aerosol concentrations and optical thickness for the regions where fire smoke was dominant in comparison with contributions of other pollution sources. The emission factors were determined separately for the forested and grassland areas; in case of mixed-type land use an intermediate scaling was assumed. Despite significant difference between the TA and FRP products, an accurate non-linear fitting between the approaches was found. The agreement was comparatively weak only for small fires where the accuracy of both products is low. The re-analysis and forecasting applications of the Fire Assimilation System (FAS) showed that both TA and FRP products are suitable for evaluation of the emission fluxes from the wild-land fires. The concentrations of aerosols predicted by the regional dispersion modelling system SILAM appear within a factor of 2-3 from observations. The main areas of improvement include further refining the emission factors over the globe, explicit determination and appropriate treatment of the type of fires, evaluation of the injection height of the plumes and predicting the fire temporal evolution.

  3. Improved Bond Equations for Fiber-Reinforced Polymer Bars in Concrete.

    PubMed

    Pour, Sadaf Moallemi; Alam, M Shahria; Milani, Abbas S

    2016-08-30

    This paper explores a set of new equations to predict the bond strength between fiber reinforced polymer (FRP) rebar and concrete. The proposed equations are based on a comprehensive statistical analysis and existing experimental results in the literature. Namely, the most effective parameters on bond behavior of FRP concrete were first identified by applying a factorial analysis on a part of the available database. Then the database that contains 250 pullout tests were divided into four groups based on the concrete compressive strength and the rebar surface. Afterward, nonlinear regression analysis was performed for each study group in order to determine the bond equations. The results show that the proposed equations can predict bond strengths more accurately compared to the other previously reported models.

  4. Technical Quality of Complete Dentures: Influence on Masticatory Efficiency and Quality of Life.

    PubMed

    Tôrres, Ana Clara Soares Paiva; Maciel, Amanda de Queiroz; de Farias, Danielle Bezerra; de Medeiros, Annie Karoline Bezerra; Vieira, Flávia Patrícia Tavares Veras; Carreiro, Adriana da Fonte Porto

    2017-11-09

    To evaluate the effect of the technical quality of conventional complete dentures (CD) on masticatory efficiency and quality of life (QoL) of denture wearers during a 1-year follow-up. A prospective clinical trial with 32 edentulous patients (mean age of 60.2 years) wearing mandibular and maxillary dentures was conducted. All patients were evaluated wearing their preexisting dentures and after 3, 6, and 12 months postinsertion of new dentures. A reproducible method for objective evaluation of the technical quality of CDs was employed. Masticatory efficiency was evaluated by the colorimetric method using beads as artificial testing food. The oral health impact on patient QoL was measured using the OHIP-EDENT (Oral Health Impact Profile in Edentulous Adults) questionnaire. The nonparametric Wilcoxon test was applied to reveal any differences in technical quality between the preexisting and new dentures. The Friedman test was used to detect differences in masticatory efficiency and oral health impact on QoL. Spearman's correlation was applied to reveal correlation between the variables. Comparing preexisting and new dentures, significant improvement was found in technical quality between the dentures (p < 0.001). There was no statistically significant difference in masticatory efficiency. A significant decrease was found in the total OHIP-EDENT scores after denture replacement. A positive correlation was found between technical quality and OHIP in the new denture wearers (p = 0.011). According to the results of this study, denture quality significantly improved patients' oral health-related QoL; however, insertion of new dentures did not influence masticatory efficiency. © 2017 by the American College of Prosthodontists.

  5. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading.

    PubMed

    Im, So-Min; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2017-02-01

    The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture ( P <.05) and the control group ( P <.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

  6. Rheology of acrylic denture-base polymers.

    PubMed

    Mutlu, G; Huggett, R; Harrison, A; Goodwin, J W; Hughes, R W

    1990-10-01

    The aim of this study was to investigate the changing rheological behavior of a denture-base polymer from mixing to setting. In addition, monomer evaporation and exothermic behavior of the mix were evaluated. The results show that the material behaves as a pseudoplastic fluid. It is shown that the viscosity increases at different rates with respect to lapsed time, and increases with higher temperature. Also, it is shown that polymerization and monomer evaporation both play a part in dough formation.

  7. The Evaluation of 3-Dimensional Polymerization Changes of a Denture Resin Utilizing Injection Molding with Water Bath Polymerization and Microwave Polymerization

    DTIC Science & Technology

    2016-06-01

    bases, in The International journal of prosthodontics. 1990. p. 528-37. 8. Gharechahi, J., et al., Dimensional Changes of Acrylic Resin Denture Bases...by Different Techniques. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2006. 22    14. Yannikakis, S., et al...Prosthodontic Graduate Program Naval Postgraduate Dental School Uniformed Services University of the Health Sciences in partial fulfillment of the

  8. Determination of the effective anticandidal concentration of denture cleanser tablets on some denture base resins

    PubMed Central

    Hayran, Yeliz; Sarikaya, Işıl; Aydin, Ali; Tekin, Yadel Hazır

    2018-01-01

    Abstract Objective Although the effectiveness of chemical cleansing against Candida albicans biofilm has been shown, the effective concentration of denture cleanser tablets has not been studied. The aim of this study was to assess the effect of three denture materials against Candida albicans biofilm and to determine effective concentrations of denture cleanser tablets. Material and methods The surface-roughness of Acron-hi™, QC-20™ and Deflex™ (n=45 per resin) resins was standardized by using a profilometer and their contact angle or surface free energy was calculated. C. albicans biofilm was formed on all three resins and were treated with Polident 3 min™, Corega™ and Fittydent™ cleanser solutions at various concentrations and both resin-biofilm and cleanser-biofilm interest were determined by using a MTT protocol according to the European Committee on Antimicrobial Susceptibility Testing's antifungal susceptibility testing (AFST-EUCAST). Scanning electron microscopy was used to compare the efficacy of different resin materials against C. albicans biofilm. Anticandidal activity and surface free energy statistical parameters were calculated by using 3-way and 1-way ANOVA, respectively (p<0.05). Results Polident 3 min™ and Corega™ tablets significantly inhibited (p<0.05) the proliferation of C. albicans against all denture resins at 27-37 mg/mL. Scanning electron microscopy results indicated that there was no significant difference among resin specimens regarding biofilm formation on dentures. We failed to find a significant relationship between surface free energy and the anticandidal effect of resin types. However, the polarity value of the resins was statistically associated with their anticandidal activity. Conclusions The polarity of the resins, the concentrations of tablets and the chemical content of the cleanser may directly affect C. albicans biofilm formations. Polident 3 min™ and Corega™ tablets should be suggested for patients who use any denture resin types, whereas the Fittydent™ tablet should only be proposed for those who use Deflex™, when two tablets are dropped into 150 mL water. PMID:29364341

  9. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study.

    PubMed

    Shekhar, Abhishek; Das, Samiran; Bhattacharyya, Jayanta; Goel, Preeti; Majumdar, Sayan; Ghosh, Soumitra

    2018-01-01

    This study aims to find the effect of change in different salivary factors before and after complete denture insertion and to measure the maxillary denture retention in different arch forms. Thirty completely edentulous individuals (10 each of square, tapered, and ovoid arch form of maxilla) belonging to the age group of 40-70 years were selected. Salivary factors (flow, density, pH, viscosity, and total protein) were evaluated before and after denture insertion. Retention of maxillary denture was measured in all the different arch forms. Student's independent sample's t -test was applied. The correlation was analyzed by Pearson's correlation analysis. While mean flow rate and pH of saliva increased, mean viscosity, total protein, and density of saliva decreased after maxillary complete denture insertion. A positive correlation was found between retention and total maxillary basal surface area. Retention value was found to be greatest in square type and least in tapered type. Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  10. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    PubMed

    Polyzois, Gregory L; de Baat, Cees

    2012-06-01

    To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. The survey took place in Greece and the Netherlands with a sample of 284 and 165 consecutive complete denture wearers, respectively, by using a 9-item prepared questionnaire. Statistical analysis relied on chi-square test at α = 0.05. In this survey, 26 and 20% of Greek and Dutch patients, respectively, had tried denture adhesive, but only 27% of them in Greece as well as in the Netherlands currently used it; 49% of the Greek and 45% of the Dutch participants rated the overall performance of adhesives as good. Between the two populations, no differences were identified in a majority of the research variables, except where 27% of Greeks answered that they did not know the existence of denture adhesives compared to none of the Dutch patients and when 90% of the Dutch contrary to 70% of Greeks reported that they did not need denture adhesives as they could manage their dentures well. The usage of and attitudes towards denture adhesives between the Greek and Dutch sample were similar with only two exceptions concerning the knowledge of existence and the need of using denture adhesives. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  11. Balance between fibroblast growth factor 10 and secreted frizzled-relate protein-1 controls the development of hair follicle by competitively regulating β-catenin signaling.

    PubMed

    Zhang, Haihua; Nan, Weixiao; Wang, Shiyong; Si, Huazhe; Li, Guangyu

    2018-07-01

    Growth of hairs depends on the regular development of hair follicles which are hypothesized to be regulated by fibroblast growth factor 10 (FGF10) and secreted frizzled-relate protein-1 (sFRP1). In the current study, the effect of FGF10 or sFRP1 on hair follicle cells was assessed and the possible mechanism mediating the interaction between FGF10 and sFRP1 in hair follicle cells was explored. Out root sheath (ORS) and dermal papilla (DP) cells were isolated from mink skin tissues and subjected to administrations of FGF10 (50 ng/ml) or sFRP1 (10 ng/ml). Then proliferation, cell cycle distribution, and migration potentials of both cell types were detected. Moreover, the nuclear translocation of β-catenin was determined. The results showed that the administration of FGF10 increased cell proliferation and migration potential in both cell types, which was associated with the up-regulated nuclear level of β-catenin. To the contrary, the administration of sFRP1 decreased cell proliferation and migration potentials while induced the G1 cell cycle arrest in both cell types by inhibiting nuclear translocation of β-catenin. Compared with the sole administrations, the co-treatment of FGF10 and sFRP1 had a medium effect on cell proliferation, cell cycle distribution, cell migration, and nuclear β-catenin level, representing an antagonistic interaction between the two factors, which was exerted by competitively regulating β-catenin pathway. Conclusively, the cycle of hair follicles was promoted by FGF10 while blocked by sFRP1 and the interplay between the two factors controlled the development of hair follicles by competitively regulating β-catenin signaling. Copyright © 2018. Published by Elsevier Masson SAS.

  12. Multidisciplinary intensive functional restoration versus outpatient active physiotherapy in chronic low back pain: a randomized controlled trial.

    PubMed

    Roche-Leboucher, Ghislaine; Petit-Lemanac'h, Audrey; Bontoux, Luc; Dubus-Bausière, Valérie; Parot-Shinkel, Elsa; Fanello, Serge; Penneau-Fontbonne, Dominique; Fouquet, Natacha; Legrand, Erick; Roquelaure, Yves; Richard, Isabelle

    2011-12-15

    Randomized parallel group comparative trial with a 1-year follow-up period. To compare in a population of patients with chronic low back pain, the effectiveness of a functional restoration program (FRP), including intensive physical training and a multidisciplinary approach, with an outpatient active physiotherapy program at 1-year follow-up. Controlled studies conducted in the United States and in Northern Europe showed a benefit of FRPs, especially on return to work. Randomized studies have compared these programs with standard care. A previously reported study presented the effectiveness at 6 months of both functional restoration and active physiotherapy, with a significantly greater reduction of sick-leave days for functional restoration. A total of 132 patients with low back pain were randomized to either FRP (68 patients) or active individual therapy (64 patients). One patient did not complete the FRP; 19 patients were lost to follow-up (4 in the FRP group and 15 in the active individual treatment group). The number of sick-leave days in 2 years before the program was similar in both groups (180 ± 135.1 days in active individual treatment vs. 185 ± 149.8 days in FRP, P = 0.847). In both groups, at 1-year follow-up, intensity of pain, flexibility, trunk muscle endurance, Dallas daily activities and work and leisure scores, and number of sick-leave days were significantly improved compared with baseline. The number of sick-leave days was significantly lower in the FRP group. Both programs are efficient in reducing disability and sick-leave days. The FRP is significantly more effective in reducing sick-leave days. Further analysis is required to determine if this overweighs the difference in costs of both programs.

  13. The Auckland Optotypes: An open-access pictogram set for measuring recognition acuity.

    PubMed

    Hamm, Lisa M; Yeoman, Janice P; Anstice, Nicola; Dakin, Steven C

    2018-03-01

    When measuring recognition acuity in a research setting, the most widely used symbols are the Early Treatment of Diabetic Retinopathy Study (ETDRS) set of 10 Sloan letters. However, the symbols are not appropriate for patients unfamiliar with letters, and acuity for individual letters is variable. Alternative pictogram sets are available, but are generally comprised of fewer items. We set out to develop an open-access set of 10 pictograms that would elicit more consistent estimates of acuity across items than the ETDRS letters from visually normal adults. We measured monocular acuity for individual uncrowded optotypes within a newly designed set (The Auckland Optotype [TAO]), the ETDRS set, and Landolt Cs. Eleven visually normal adults were assessed on regular and vanishing formats of each set. Inter-optotype reliability and ability to detect subtle differences between participants were assessed using intraclass correlations (ICC) and fractional rank precision (FRP). The TAO vanishing set showed the strongest performance (ICC = 0.97, FRP = 0.90), followed by the other vanishing sets (Sloan ICC = 0.88, FRP = 0.74; Landolt ICC = 0.86, FRP = 0.80). Within the regular format, TAO again outperformed the existing sets (TAO ICC = 0.77, FRP = 0.75; Sloan ICC = 0.65, FRP = 0.64; Landolt ICC = 0.48, FRP = 0.63). For adults with normal visual acuity, the new optotypes (in both regular and vanishing formats) are more equally legible and sensitive to subtle individual differences than their Sloan counterparts. As this set does not require observers to be able to name Roman letters, and is freely available to use and modify, it may have wide application for measurement of acuity.

  14. Use of a Molecular Decoy to Segregate Transport from Antigenicity in the FrpB Iron Transporter from Neisseria meningitidis

    PubMed Central

    Saleem, Muhammad; Prince, Stephen M.; Rigby, Stephen E. J.; Imran, Muhammad; Patel, Hema; Chan, Hannah; Sanders, Holly; Maiden, Martin C. J.; Feavers, Ian M.; Derrick, Jeremy P.

    2013-01-01

    FrpB is an outer membrane transporter from Neisseria meningitidis, the causative agent of meningococcal meningitis. It is a member of the TonB-dependent transporter (TBDT) family and is responsible for iron uptake into the periplasm. FrpB is subject to a high degree of antigenic variation, principally through a region of hypervariable sequence exposed at the cell surface. From the crystal structures of two FrpB antigenic variants, we identify a bound ferric ion within the structure which induces structural changes on binding which are consistent with it being the transported substrate. Binding experiments, followed by elemental analysis, verified that FrpB binds Fe3+ with high affinity. EPR spectra of the bound Fe3+ ion confirmed that its chemical environment was consistent with that observed in the crystal structure. Fe3+ binding was reduced or abolished on mutation of the Fe3+-chelating residues. FrpB orthologs were identified in other Gram-negative bacteria which showed absolute conservation of the coordinating residues, suggesting the existence of a specific TBDT sub-family dedicated to the transport of Fe3+. The region of antigenic hypervariability lies in a separate, external sub-domain, whose structure is conserved in both the F3-3 and F5-1 variants, despite their sequence divergence. We conclude that the antigenic sub-domain has arisen separately as a result of immune selection pressure to distract the immune response from the primary transport function. This would enable FrpB to function as a transporter independently of antibody binding, by using the antigenic sub-domain as a ‘molecular decoy’ to distract immune surveillance. PMID:23457610

  15. Use of a molecular decoy to segregate transport from antigenicity in the FrpB iron transporter from Neisseria meningitidis.

    PubMed

    Saleem, Muhammad; Prince, Stephen M; Rigby, Stephen E J; Imran, Muhammad; Patel, Hema; Chan, Hannah; Sanders, Holly; Maiden, Martin C J; Feavers, Ian M; Derrick, Jeremy P

    2013-01-01

    FrpB is an outer membrane transporter from Neisseria meningitidis, the causative agent of meningococcal meningitis. It is a member of the TonB-dependent transporter (TBDT) family and is responsible for iron uptake into the periplasm. FrpB is subject to a high degree of antigenic variation, principally through a region of hypervariable sequence exposed at the cell surface. From the crystal structures of two FrpB antigenic variants, we identify a bound ferric ion within the structure which induces structural changes on binding which are consistent with it being the transported substrate. Binding experiments, followed by elemental analysis, verified that FrpB binds Fe(3+) with high affinity. EPR spectra of the bound Fe(3+) ion confirmed that its chemical environment was consistent with that observed in the crystal structure. Fe(3+) binding was reduced or abolished on mutation of the Fe(3+)-chelating residues. FrpB orthologs were identified in other Gram-negative bacteria which showed absolute conservation of the coordinating residues, suggesting the existence of a specific TBDT sub-family dedicated to the transport of Fe(3+). The region of antigenic hypervariability lies in a separate, external sub-domain, whose structure is conserved in both the F3-3 and F5-1 variants, despite their sequence divergence. We conclude that the antigenic sub-domain has arisen separately as a result of immune selection pressure to distract the immune response from the primary transport function. This would enable FrpB to function as a transporter independently of antibody binding, by using the antigenic sub-domain as a 'molecular decoy' to distract immune surveillance.

  16. Shape Optimization for Additive Manufacturing of Removable Partial Dentures - A New Paradigm for Prosthetic CAD/CAM

    PubMed Central

    2015-01-01

    With ever-growing aging population and demand for denture treatments, pressure-induced mucosa lesion and residual ridge resorption remain main sources of clinical complications. Conventional denture design and fabrication are challenged for its labor and experience intensity, urgently necessitating an automatic procedure. This study aims to develop a fully automatic procedure enabling shape optimization and additive manufacturing of removable partial dentures (RPD), to maximize the uniformity of contact pressure distribution on the mucosa, thereby reducing associated clinical complications. A 3D heterogeneous finite element (FE) model was constructed from CT scan, and the critical tissue of mucosa was modeled as a hyperelastic material from in vivo clinical data. A contact shape optimization algorithm was developed based on the bi-directional evolutionary structural optimization (BESO) technique. Both initial and optimized dentures were prototyped by 3D printing technology and evaluated with in vitro tests. Through the optimization, the peak contact pressure was reduced by 70%, and the uniformity was improved by 63%. In vitro tests verified the effectiveness of this procedure, and the hydrostatic pressure induced in the mucosa is well below clinical pressure-pain thresholds (PPT), potentially lessening risk of residual ridge resorption. This proposed computational optimization and additive fabrication procedure provides a novel method for fast denture design and adjustment at low cost, with quantitative guidelines and computer aided design and manufacturing (CAD/CAM) for a specific patient. The integration of digitalized modeling, computational optimization, and free-form fabrication enables more efficient clinical adaptation. The customized optimal denture design is expected to minimize pain/discomfort and potentially reduce long-term residual ridge resorption. PMID:26161878

  17. Study on digital teeth selection and virtual teeth arrangement for complete denture.

    PubMed

    Yu, Xiaoling; Cheng, Xiaosheng; Dai, Ning; Chen, Hu; Yu, Changjiang; Sun, Yuchun

    2018-03-01

    In dentistry, the complete denture is a conventional treatment for edentulous patients. The computer-aided design and computer-aided manufacturing (CAD/CAM) has been applied on the digital complete denture which is developed rapidly. Tooth selection and arrangement is one of the most important parts in digital complete denture. In this paper, we propose a new method of personalized teeth arrangement. This paper presents a method of arranging teeth virtually for a complete denture. First, scan and extract the feature points of the 3D triangular mesh data of artificial teeth (PLY format), then establish a tooth selection system. Second, scan and mark the anatomic characteristics of the maxillary and mandibular cast surfaces, such as facial midline, the curve of the arches. With the enter information, the study calculates the common arrangement lines of artificial teeth. Third, select the preferred artificial teeth and automatically arrange them virtually in the correct position by using our own software. After that, design the gingival part of the dentures on the basic of the arranged teeth on the screen and then fabricated it by using Computerized Numerical Control (CNC) technology, Rapid Prototyping (RP) technology or 3D printer technology. Finally, select artificial teeth were embedded in wax rims. This system can choose artificial teeth reasonably and the teeth placement can meet the dentist's request to a certain extent, whereas all the operations are based on the medical principles. The study performed here involves computer sciences, medicine, and dentistry, a teeth selection system was proposed and virtual teeth arrangement was described. This study has the capacity of helping operators to select teeth, which improved the accuracy of tooth arrangement, and customized complete denture. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Patient ratings of chewing ability from a randomised crossover trial: lingualised vs. first premolar/canine-guided occlusion for complete dentures.

    PubMed

    Heydecke, Guido; Akkad, Ahmed Shadi; Wolkewitz, Martin; Vogeler, Michael; Türp, Jens C; Strub, Joerg R

    2007-06-01

    Complex procedures involving a facebow transfer and the use of lingualised teeth are deemed to have a positive influence on the chewing ability with complete dentures. To determine if patients' ratings of their ability to chew depend on the method of complete denture fabrication. Edentulous patients (n = 20) participated in a within-subject crossover trial. Each patient received two sets of new complete dentures. One pair was manufactured based on intraoral tracing of centric relation and facebow transfer; semi-anatomical teeth with lingualised occlusion denture (LOD) were chosen. The second pair was made using a simplified procedure without facebow transfer; jaw relations were recorded with wax occlusion rims, and anatomical teeth with a first premolar/canine-guidance (CGD) were selected. The dentures were delivered in randomised order, and each was worn for 3 months. Three months after delivery, patients' ratings of each new prosthesis were recorded on visual analogue scales for their ability to chew seven index foods. Repeated measurements analysis of variance was performed to investigate possible carry-over effects accounting for confounding by treatment period. When comparing the two treatments, participants rated their ability to chew in general, to masticate carrots, hard sausage, steak and raw apple in particular, was significantly better with the CGD (anatomical teeth) than with the LOD (p < 0.05). Comprehensive methods for the fabrication of complete dentures including semi-anatomical lingualised teeth and a full registration do not seem to influence the perceived chewing ability, when compared with more simple procedures. Chewing ability for tough foods appears to benefit from the use of anatomical teeth.

  19. Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up

    PubMed Central

    Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M.

    2016-01-01

    Statement of Problem: In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. Aims and Objective: The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. Materials and Methods: The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan–Meier method. Results: None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. Conclusion: DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study. PMID:27141171

  20. Chronological grey scale changes in supporting alveolar bone by removable partial denture placement on patients with periodontal disease: A 6-month follow-up study using digital subtraction analysis.

    PubMed

    Watanabe, Chie; Wada, Junichiro; Mizutani, Koji; Watanabe, Hiroshi; Wakabayashi, Noriyuki

    2017-08-01

    The purpose was to assess the early effects of removable partial denture (RPD) placement on abutment teeth in patients with periodontal disease. Fifteen distal-extension RPDs and 19 abutment teeth were evaluated in 13 patients with moderate-to-severe periodontal diseases. Clinical periodontal records and grey level (GL) score based on digital subtraction radiography were measured on the day of denture placement (baseline) and at 1day, 1 week, 1 month, 3 months, and 6 months after the placement. Occlusal force on total dentition (Ft) and abutment tooth (Fa) were recorded with (baseline) and without denture on the day of the placement, and with denture in the follow-up examinations. No statistically significant difference between a follow-up period and the baseline was found in the clinical periodontal and occlusal force records, except for Ft with denture on the day of the placement, which was significantly lower than the baseline (p<0.05). The GL at distal crestal of the abutment was significantly higher at 1 week after the placement than at the baseline (p<0.05), while the scores of following examinations returned to the baseline level. The distal crestal bone of the abutment tooth transitorily reacts to mechanical stress due to the denture placement, while this does not suggest a detrimental effect within the limitation of the study design with a short-term observation period. The RPDs can be safely used for patients with periodontal diseases for at least 6 months if they are properly placed and maintained by professional care. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. CHIPPING FRACTURE RESISTANCE OF DENTURE TOOTH MATERIALS

    PubMed Central

    Quinn, G. D.; Giuseppetti, A. A.; Hoffman, K. H.

    2014-01-01

    Objective The applicability of the edge chipping method to denture tooth materials was assessed. These are softer materials than those usually tested by edge chipping. The edge chipping fracture resistances of polymethylmethacrylate (PMMA) based and two filled resin composite denture tooth materials were compared. Methods An edge chipping machine was used to chip rectangular blocks and flattened anterior denture teeth. Force versus edge distance data were collected over a broad range of forces and distances. Between 20 and 65 chips were made per condition depending upon the material, the scatter, and the indenter type. Different indenter types were used including Rockwell C, sharp conical 120°, Knoop, and Vickers. The edge toughness, Te, was evaluated for different indenter types. Results The edge chipping data collected on the blocks matched the data collected from flattened teeth. High scatter, particularly at large distances and loads, meant that many tests (up to 64) were necessary to compare the denture tooth materials and to ascertain the appropriate data trends. A linear force – distance trend analysis was adequate for comparing these materials. A power law trend might be more appropriate, but the large scatter obscured the definitive determination of the precise trend. Different indenters produce different linear trends, with the ranking of: sharp conical 120°, Rockwell C, and Knoop, from lowest to highest edge toughness. Vickers indenter data were extremely scattered and a sensible trend could not be obtained. Edge toughness was inversely correlated to hardness. Significance Edge chipping data collected either from simple laboratory scale test blocks or from actual denture teeth may be used to evaluate denture materials. The edge chipping method’s applicability has been extended to another class of restorative materials. PMID:24674342

  2. Measuring Radiant Emissions from Entire Prescribed Fires with Ground, Airborne and Satellite Sensors RxCADRE 2012

    NASA Technical Reports Server (NTRS)

    Dickinson, Matthew B.; Hudak, Andrew T.; Zajkowski, Thomas; Loudermilk, E. Louise; Schroeder, Wilfrid; Ellison, Luke; Kremens, Robert L.; Holley, William; Martinez, Otto; Paxton, Alexander; hide

    2015-01-01

    Characterising radiation from wildland fires is an important focus of fire science because radiation relates directly to the combustion process and can be measured across a wide range of spatial extents and resolutions. As part of a more comprehensive set of measurements collected during the 2012 Prescribed Fire Combustion and Atmospheric Dynamics Research (RxCADRE) field campaign, we used ground, airborne and spaceborne sensors to measure fire radiative power (FRP) from whole fires, applying different methods to small (2 ha) and large (.100 ha) burn blocks. For small blocks (n1/46), FRP estimated from an obliquely oriented long-wave infrared (LWIR) camera mounted on a boom lift were compared with FRP derived from combined data from tower-mounted radiometers and remotely piloted aircraft systems (RPAS). For large burn blocks (n1/43), satellite FRP measurements from the Moderate-resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) sensors were compared with near-coincident FRP measurements derived from a LWIR imaging system aboard a piloted aircraft. We describe measurements and consider their strengths and weaknesses. Until quantitative sensors exist for small RPAS, their use in fire research will remain limited. For oblique, airborne and satellite sensors, further FRP measurement development is needed along with greater replication of coincident measurements, which we show to be feasible.

  3. Complete denture services: clinical technique, lab costs, manpower, and reimbursement. One-year review.

    PubMed

    Ewoldsen, Nels

    2011-01-01

    Complete denture services at comprehensive care public health clinics are not common in part because of clinician concerns regarding outcomes. Educational debt forgiveness has attracted recent dental graduates to public health dentistry; however, not all recent graduates receive denture education experiences necessary to attain proficiency. While fundamental patient assessment and denture construction are taught, psychological assessment and communication with denture patients requires experience. A thorough understanding of occlusion, phonetics, esthetics and laboratory steps is also necessary. Expecting recent dental graduates to become proficient providing complete dentures at minimal reimbursement levels, with no mentorship or on-site laboratory support, is unrealistic. Public health dental clinics operate at full capacity performing emergency, preventive and restorative procedures. Complete dentures come with a laboratory fee approximately one-half the total reimbursement, meaning a remake drops clinic revenue to zero while doubling expenses. It is understandable that full schedules, marginal reimbursement, unpredictability and the risk of an occasional failure block clinician interest in providing denture services. This one-year report of services describes a three-appointment complete denture technique offering improved patient and laboratory communication, reduced chair time and controlled cost, resulting in high-quality complete dentures.

  4. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

    PubMed Central

    2017-01-01

    PURPOSE The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr–Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS Glass fiber mesh- and Cr–Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair. PMID:28243388

  5. Oral health-related quality of life in patients with non-metal clasp dentures: a randomised cross-over trial.

    PubMed

    Fueki, K; Yoshida-Kohno, E; Wakabayashi, N

    2017-05-01

    We investigated the efficacy of non-metal clasp dentures (NMCDs) with regard to the oral health-related quality of life (OHRQoL) and compare the findings with those for conventional metal clasp-retained dentures (MCDs). This single-centre, randomised controlled, two-phase, open label, cross-over trial included 28 partially dentate individuals. The patients were randomised to receive MCDs followed by NMCDs, or the opposite sequence (n = 14 in each group); each denture was worn for 3 months. OHRQoL was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J) at entry (T-entry; before treatment with the first denture) and at 3 months after treatment with each denture (T3). An examiner evaluated denture stability, oral appearance and surface roughness before denture delivery (T0) and at T3 and denture hygiene at T3. A total of 24 patients completed the trial. There were no complications related to the dentures, abutment teeth or denture-bearing mucosa during the follow-up periods for both dentures. The mean OHIP summary score was lower for NMCDs than for MCDs, and the difference (9 points) was greater than the minimal important difference (6 points), indicating the difference was clinically relevant. The effect size was medium (0·70). Statistical analyses with linear mixed models found a significant effect of the denture type on the OHIP summary score and scores for the Oro-facial appearance, Oro-facial pain and Psychological impact domains (NMCD < MCD; P < 0·05). The results of our study suggest that NMCDs allow for better OHRQoL compared with MCDs. © 2017 John Wiley & Sons Ltd.

  6. Nde of Frp Wrapped Columns Using Infrared Thermography

    NASA Astrophysics Data System (ADS)

    Halabe, Udaya B.; Dutta, Shasanka Shekhar; GangaRao, Hota V. S.

    2008-02-01

    This paper investigates the feasibility of using Infrared Thermography (IRT) for detecting debonds in Fiber Reinforced Polymer (FRP) wrapped columns. Laboratory tests were conducted on FRP wrapped concrete cylinders of size 6″×12″ (152.4 mm×304.8 mm) in which air-filled and water-filled debonds of various sizes were placed underneath the FRP wraps. Air-filled debonds were made by cutting plastic sheets into the desired sizes whereas water-filled debonds were made by filling water in custom made polyethylene pouches. Both carbon and glass fiber reinforced wraps were considered in this study. Infrared tests were conducted using a fully radiometric digital infrared camera which was successful in detecting air-filled as well as water-filled subsurface debonds. In addition to the laboratory testing, two field trips were made to Moorefield, West Virginia for detecting subsurface debonds in FRP wrapped timber piles of a railroad bridge using infrared testing. The results revealed that infrared thermography can be used as an effective nondestructive evaluation tool for detecting subsurface debonds in structural components wrapped with carbon or glass reinforced composite fabrics.

  7. Concrete Open-Wall Systems Wrapped with FRP under Torsional Loads

    PubMed Central

    Mancusi, Geminiano; Feo, Luciano; Berardi, Valentino P.

    2012-01-01

    The static behavior of reinforced concrete (RC) beams plated with layers of fiber-reinforced composite material (FRP) is widely investigated in current literature, which deals with both its numerical modeling as well as experiments. Scientific interest in this topic is explained by the increasing widespread use of composite materials in retrofitting techniques, as well as the consolidation and upgrading of existing reinforced concrete elements to new service conditions. The effectiveness of these techniques is typically influenced by the debonding of the FRP at the interface with concrete, where the transfer of stresses occurs from one element (RC member) to the other (FRP strengthening). In fact, the activation of the well-known premature failure modes can be regarded as a consequence of high peak values of the interfacial interactions. Until now, typical applications of FRP structural plating have included cases of flexural or shear-flexural strengthening. Within this context, the present study aims at extending the investigation to the case of wall-systems with open cross-section under torsional loads. It includes the results of some numerical analyses carried out by means of a finite element approximation.

  8. Role of DDC-4/sFRP-4, a secreted frizzled-related protein, at the onset of apoptosis in mammary involution.

    PubMed

    Lacher, M D; Siegenthaler, A; Jäger, R; Yan, Xi; Hett, S; Xuan, L; Saurer, S; Lareu, R R; Dharmarajan, A M; Friis, R

    2003-05-01

    Using differential display, we isolated DDC-4, a secreted frizzled-related protein (sFRP), which is induced in the physiological apoptosis of hormonally regulated, reproductive tissues such as mammary gland, prostate, corpus luteum and uterus. The role of this gene in apoptosis was studied in animals overexpressing ectopic DDC-4/sFRP-4. Transgenic mice bearing the DDC-4/sFRP-4 cDNA under the control of the MMTV-LTR promoter showed lactational insufficiency and many apoptotic cells in the alveoli between day 19 of pregnancy and day 4 of lactation as demonstrated by TUNEL reaction and the presence of activated caspase-3. We performed a PKB/Akt kinase assay and studied several of its substrates using phosphorylation-specific antibodies to show reduced phosphorylation in PKB/Akt itself, as well as in glycogen synthetase kinase-3beta (GSK-3beta), BAD, and Forkhead. Taken together, our results show a role for DDC-4/sFRP-4 in abrogating an epithelial cell survival pathway at the onset of mammary gland involution.

  9. An Experimental Evaluation of Mechanical Properties of Hybrid Reinforcements

    NASA Astrophysics Data System (ADS)

    Sai Kumar, A.; Ganesan, G.; Karthikeyan, K.

    2017-07-01

    This paper presents the mechanical properties of unidirectional hybrid reinforcements formed from continuous fibres impregnated with a fibre binding material which are used for reinforcing the concrete. Recently FRP (Fibre Reinforced Polymer) manufacturers and suppliers have been increased all over the world because of the superior performance of FRP products in the construction industry. Its non-corrosive nature has turned the attention of many researchers to make several studies on different type of FRP products. Through a vast research, several standards also have been formulated. In this regard a new combination of FRP materials is tried in this paper and its properties have been derived. Carbon fibre and glass fibres fuse in this study to form a new hybrid rebar. The design properties such as tensile strength, tensile modulus, and compressive strength have been studied as per ASTM standards and it has been identified that the Hybrid rebar show a superior performance in comparison with GFRP (Glass FRP) and Steel rebars. This extraordinary performance of hybrid composite material increases the extensive engineering applications such as transport industry, aeronautics, naval, automotive industries.

  10. Characterization of two types of osteoclasts from human peripheral blood monocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuasa, Kimitaka; Mori, Kouki; Ishikawa, Hitoshi

    2007-05-04

    The two osteoclastogenesis pathways, receptor activator nuclear factor (NF)-{kappa}B ligand (RANKL)-mediated and fusion regulatory protein-1 (FRP-1)-mediated osteoclastogenesis, have recently been reported. There were significant differences in differentiation and activation mechanisms between the two pathways. When monocytes were cultured with FRP-1 without adding M-CSF, essential for the RANKL system, TRAP-positive polykaryocyte formation occurred. FRP-1-mediated osteoclasts formed larger pits on mineralized calcium phosphate plates than RANKL+M-CSF-mediated osteoclasts did. Lacunae on dentin surfaces induced by FRP-1-mediated osteoclasts were inclined to be single and isolated. However, osteoclasts induced by RANKL+M-CSF made many connected pits on dentin surfaces as if they crawled on there. Interestingly,more » FRP-1 osteoclastogenesis was enhanced by M-CSF/IL-1{alpha}, while chemotactic behavior to the dentin slices was not effected. There were differences in pH and concentration of HCO3- at culture endpoint and in adherent feature to dentin surfaces. Our findings indicate there are two types of osteoclasts with distinct properties.« less

  11. Vibrational characteristics of FRP-bonded concrete interfacial defects in a low frequency regime

    NASA Astrophysics Data System (ADS)

    Cheng, Tin Kei; Lau, Denvid

    2014-04-01

    As externally bonded fiber-reinforced polymer (FRP) is a critical load-bearing component of strengthened or retrofitted civil infrastructures, the betterment of structural health monitoring (SHM) methodology for such composites is imperative. Henceforth the vibrational characteristics of near surface interfacial defects involving delamination and trapped air pockets at the FRP-concrete interface are investigated in this study using a finite element approach. Intuitively, due to its lower interfacial stiffness compared with an intact interface, a damaged region is expected to have a set of resonance frequencies different from an intact region when excited by acoustic waves. It has been observed that, when excited acoustically, both the vibrational amplitudes and frequency peaks in the response spectrum of the defects demonstrate a significant deviation from an intact FRP-bonded region. For a thin sheet of FRP bonded to concrete with sizable interfacial defects, the fundamental mode under free vibration is shown to be relatively low, in the order of kHz. Due to the low resonance frequencies of the defects, the use of low-cost equipment for interfacial defect detection via response spectrum analysis is highly feasible.

  12. Denture labeling: A new approach

    PubMed Central

    Bansal, Pardeep K.; Sharma, Akshey; Bhanot, Rajesh

    2011-01-01

    The need for denture labeling is important for forensic and social reasons in case patients need to be identified individually. The importance of denture marking has long been acknowledged by the dental profession. Over the years, various denture marking systems have been reported in the literature, but none till date fulfills all the prescribed ADA specifications. A simple, easy, inexpensive procedure for marking accurate identification marks on dentures with a lead foil is described here. The label caring the patient information is incorporated in the acrylic resin during the denture processing. PMID:21957379

  13. Dental Laboratory Career Ladder (AFSC 4Y1X1)

    DTIC Science & Technology

    1994-08-01

    analysis identified one job cluster and seven jobs: Base Dental Lab cluster, Orthodontic Appliance Fabricator job, Fixed Restoration Fabricator job, Crown...reline and repair, removable partial denture construction, crown and fixed partial denture construction, fabrication of orthodontic appliances, and...specialized prostheses. Preventive maintenance and safety precautions for dental laboratory equipment are also stressed . Entry into the career ladder

  14. [Burning mouth caused by denture material].

    PubMed

    Feilzer, A J

    2009-09-01

    A 60-year-old man with an edentulous maxilla was referred by his dentist to an allergy clinic with complaints of burning mouth and bad taste. In the majority of cases, it is hard or impossible to detect the cause of burning mouth. In this case, ultimately the complaint could be solved by eliminating exposure to possible allergenic components of denture base resins.

  15. The effect of denture adhesives on Candida albicans growth in vitro.

    PubMed

    Sampaio-Maia, Benedita; Figueiral, Maria Helena; Sousa-Rodrigues, Patricia; Fernandes, Maria Helena; Scully, Crispian

    2012-06-01

    Denture-wearing favours the growth of Candida. In view of the fact that many denture wearers regularly use adhesives to enhance denture retention, stability and function, the aim of this work was to study the effect of denture adhesives on Candida albicans growth in vitro. The denture adhesives tested were Corega(®) cream, Kukident(®) cream, Novafix(®) cream, Polident(®) cream, Protefix(®) cream, Steradent(®) cream, Aderyn(®) powder, Corega(®) ultra powder, Protefix(®) powder and Corega(®) strip. C. albicans growth curves were obtained in the presence or absence of a 1% solution of the denture adhesive diluted in Sabouraud broth. Macro- and microscopic morphological changes in C. albicans were analysed, as was microbial contamination of the denture adhesive. Most of the denture adhesives studied induced morphological changes in C. albicans cells and colonies, but only two had any significant inhibitory effect on yeast growth. Kukident(®) cream markedly inhibited C. albicans growth in a concentration-dependent way, reducing the growth rate by 95%, whereas Corega(®) cream also inhibited C. albicans growth but in a non-concentration-dependent way, reducing the growth rate by 37%. In addition, denture adhesives available as powders had detectable microbial contamination. Some commercially available denture adhesives showed microbial contamination and some had significant inhibitory effect on C. albicans growth. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  16. Knowledge of removable partial denture wearers on denture hygiene.

    PubMed

    Milward, P; Katechia, D; Morgan, M Z

    2013-11-01

    Regular good denture hygiene by individuals with removable partial dentures (RPDs) is an important component of oral health and in the prevention of further dental problems. These individuals should be provided with advice on the importance of denture care and be aware of this information. To establish deficiencies in patient knowledge surrounding denture hygiene by RPD wearers. The study was undertaken as an audit. Data was collected from April 2012 to October 2012 via a questionnaire completed by 196 RPD wearers attending as patients at the University Dental Hospital Wales and the dental units at St David's Hospital and Cynon Valley Hospital. The audit criterion was patients with RPDs should have knowledge of denture hygiene, with the standard set at 100%. While 91.8% of participants stated they were provided with instructions on denture hygiene when provided with their current prosthesis, 60.2% were shown to have less than an appropriate level of denture cleanliness, with 9.2% reporting that they slept wearing their prosthesis. The audit criterion and standard set were not achieved. A lack of knowledge surrounding denture hygiene was demonstrated among participants. As a part of the audit process the health education of RPD wearers' hygiene needs to be improved and awareness levels of the whole dental team needs to be raised. All partial dentures should receive information and regular reinforcement of key dental hygiene messages.

  17. The effect of joint surface contours and glass fiber reinforcement on the transverse strength of repaired acrylic resin: An in vitro study.

    PubMed

    Anasane, Nayana; Ahirrao, Yogesh; Chitnis, Deepa; Meshram, Suresh

    2013-03-01

    Denture fracture is an unresolved problem in complete denture prosthodontics. However, the repaired denture often experiences a refracture at the repaired site due to poor transverse strength. Hence, this study was conducted to evaluate the effect of joint surface contours and glass fiber reinforcement on the transverse strength of repaired acrylic resins. A total of 135 specimens of heat polymerized polymethyl methacrylate resin of dimensions 64 × 10 × 2.5 mm were fabricated. Fifteen intact specimens served as the control and 120 test specimens were divided into four groups (30 specimens each), depending upon the joint surface contour (butt, bevel, rabbet and round), with two subgroups based on type of the repair. Half of the specimens were repaired with plain repair resin and the other half with glass fibers reinforced repair resin. Transverse strength of the specimens was determined using three-point bending test. The results were analyzed using one-way ANOVA and Tukey post-hoc test (α= 0.05). Transverse strength values for all repaired groups were significantly lower than those for the control group (P < 0.001) (88.77 MPa), with exception of round surface design repaired with glass fiber reinforced repair resin (89.92 MPa) which was significantly superior to the other joint surface contours (P < 0.001). Glass fiber reinforced resin significantly improved the repaired denture base resins as compared to the plain repair resin (P < 0.001). Specimens repaired with glass fiber reinforced resin and round surface design exhibited highest transverse strength; hence, it can be advocated for repair of denture base resins.

  18. Different types of antagonists modify the outcome of complete denture renewal.

    PubMed

    Berteretche, Marie Violaine; Frot, Amélie; Woda, Alain; Pereira, Bruno; Hennequin, Martine

    2015-01-01

    The effect of renewing removable dentures on masticatory function was evaluated according to the occlusion offered by different types of mandibular arches. Twenty-eight patients with complete maxillary dentures were subdivided into three groups in terms of mandibular dentition type: dentate, partial denture, and complete denture. The participants were observed before and 8 weeks after maxillary denture renewal. The mandibular denture was also renewed in the partial and complete denture groups. The participants masticated carrots, peanuts, and three model foods of different hardnesses. The particle size distribution of the boluses obtained from natural foods was characterized by the median particle size (d50) in relation to the masticatory normative indicator (MNI). Chewing time (CT), number of chewing cycles (CC), and chewing frequency (CF) were video recorded. A self-assessment questionnaire for oral health-related quality of life (Geriatric Oral Health Assessment Index [GOHAI]) was used. Statistical analyses were carried out with a mixed model. Renewal of the dentures decreased d50 (P < .001). The number of participants with d50 values above the MNI cutoff decreased from 12 to 2 after renewal. Renewal induced an increase in mean CF while chewing model foods (P < .001). With all foods, renewal tended to affect CT, CC, and CF differently among the three groups (statistically significant renewal Å~ group interactions). The GOHAI score increased significantly for all groups. Denture renewal improves masticatory function. The complete denture group benefited least from renewal; the dentate group benefited most. This study confirmed the usefulness of denture renewal for improving functions and oral health- related quality of life.

  19. Evaluation of cleansing methods for previously worn prostheses.

    PubMed

    Glass, R Thomas; Conrad, Robert S; Bullard, James W; Goodson, Leigh B; Mehta, Naresh; Lech, Stanley J; Loewy, Zvi G

    2011-04-01

    Although there are many product claims that address the issue of denture sanitization, controlled scientific studies on previously worn dentures have not been performed. The purpose of this study was to evaluate procedures directed at sanitizing previously worn contaminated dentures from two regions of the United States. This study examined 51 previously worn dentures from two regions. An established method of denture retrieval, sectioning, and culturing was used, including isolation of anaerobes. Evaluation of microbial contamination posttreatment was used to determine the effects of soaking dentures in Polident (US and European formulations) for varying periods of times/temperatures, microwaving dentures with varying temperatures, sonicating dentures, and immersing the dentures while using a vacuum. A combination of analysis of variance (ANOVA) and general linear model (GLM) of the SPSS was used to analyze the data with P < .05 being considered statistically significant when using a two-tailed test. While all Polident treatments were found to significantly reduce microorganism loads in dentures, extended soaking (8 hours) and 65 degrees C (5 minutes) were the most effective. Microwaving was slightly more effective than either sonication or vacuum. Regardless the treatment, dentures underwent sanitization rather than sterilization. Denture-borne microorganisms can be significantly reduced by using a Polident solution for 8 hours at room temperature or for 5 minutes at 65 degrees C. Microwaving, sonication, and use of a vacuum were less effective. ClLINICAL IMPLICATIONS The importance of daily use of Polident solution for 8 hours or for 5 minutes at 65 degrees C to sanitize worn prostheses must be stressed.

  20. [Guywire dentures].

    PubMed

    Riakhovskiĭ, A N

    2000-01-01

    Analyzes possible complications and shortcomings of traditional prosthetic treatments. Presents a new approach to prosthetic treatment and describes the general design of guy dentures. Describes in brief the biomechanics, methods of making guy dentures, and discusses their advantages in comparison with the traditional dentures.

  1. Smart-aggregate-based damage detection of fiber-reinforced-polymer-strengthened columns under reversed cyclic loading

    NASA Astrophysics Data System (ADS)

    Howser, Rachel; Moslehy, Yashar; Gu, Haichang; Dhonde, Hemant; Mo, Y. L.; Ayoub, Ashraf; Song, Gangbing

    2011-07-01

    Structural health monitoring is an important aspect of the maintenance of large civil infrastructures, especially for bridge columns in areas of high seismic activity. In this project, recently developed innovative piezoceramic-based sensors were utilized to perform the health monitoring of a shear-critical reinforced concrete (RC) bridge column subjected to reversed cyclic loading. After the column failed, it was wrapped with fiber reinforced polymer (FRP) sheets, commonly used to retrofit seismically damaged structures. The FRP-strengthened column was retested under the same reversed cyclic loading pattern. Innovative piezoceramic-based sensors, called 'smart aggregates', were utilized as transducers for health monitoring purposes. On the basis of the smart aggregates developed, an active-sensing approach and an impact-hammer-based approach were used to evaluate the health status of the RC column during the loading procedure. Wave transmission energy is attenuated by the existence of cracks during the loading procedure, and this attenuation phenomenon alters the curve of the transfer function between the actuator and sensor. To detect the damage occurrence and evaluate the damage severity, transfer function curves were compared with those obtained during the period of healthy status. A transfer-function-based damage index matrix was developed to demonstrate the damage severity at different locations. Experimental results verified the effectiveness of the smart aggregates in health monitoring of the FRP-strengthened column as well as the unstrengthened column. The experimental results show that the proposed smart-aggregate-based approach can successfully detect damage occurrence and evaluate its severity.

  2. The stress-strain relationships in wood and fiber-reinforced plastic laminae of reinforced glued-laminated wood beams

    NASA Astrophysics Data System (ADS)

    Tingley, Daniel Arthur

    The reinforcement of wood and wood composite structural products to improve their mechanical properties has been in practice for many years. Recently, the use of high-strength fiber-reinforced plastic (FRP) as a reinforcement in such applications has been commercialized. The reinforcement is manufactured using a standard pultrusion process or alternatively a sheet-forming process commonly referred to as "pulforming". The high-modulus fibers are predominately unidirectional, although off-axis fibers are often used to enhance off-axis properties. The fibers used are either of a single type or multiple types, which are called "hybrids". Unidirectional, single, and hybrid fiber FRP physical properties and characteristics were compared to wood. Full-scale reinforced glulams were tested. Aramid-reinforced plastics (ARP) used as tensile reinforcements were found to be superior in strength applications to other types of FRP made with fiber, such as carbon and fiberglass. Carbon/aramid-reinforced plastic (CARP) was shown to be superior in both modulus and strength design situations. Fiberglass was shown to be suitable only in hybrid situations with another fiber such as aramid or carbon and only in limited use situations where modulus was a design criteria. The testing and analysis showed that the global response of reinforced glulam beams is controlled by localized strength variations in the wood such as slope of grain, knots, finger joints, etc. in the tensile zone. The elemental tensile strains in the extreme wood tensile laminae, due to global applied loads, were found to be well below the strain at failure in clear wood samples recovered from the failure area. Two areas affecting the relationship between the wood and the FRP were investigated: compatibility of the wood and FRP materials and interface characteristics between the wood and FRP. The optimum strain value at yield point for an FRP was assessed to be slightly higher than the clear wood value in tension for a species/grade to be reinforced. The effects of localized strength variations in the tensile wood laminae adjacent to the FRP were found to be the predominate cause of failure in full-scale reinforced glulams with less than 1.5% by cross section reinforcement.

  3. Fit-for-purpose phosphorus management: do riparian buffers qualify in catchments with sandy soils?

    PubMed

    Weaver, David; Summers, Robert

    2014-05-01

    Hillslope runoff and leaching studies, catchment-scale water quality measurements and P retention and release characteristics of stream bank and catchment soils were used to better understand reasons behind the reported ineffectiveness of riparian buffers for phosphorus (P) management in catchments with sandy soils from south-west Western Australia (WA). Catchment-scale water quality measurements of 60 % particulate P (PP) suggest that riparian buffers should improve water quality; however, runoff and leaching studies show 20 times more water and 2 to 3 orders of magnitude more P are transported through leaching than runoff processes. The ratio of filterable reactive P (FRP) to total P (TP) in surface runoff from the plots was 60 %, and when combined with leachate, 96 to 99 % of P lost from hillslopes was FRP, in contrast with 40 % measured as FRP at the large catchment scale. Measurements of the P retention and release characteristics of catchment soils (<2 mm) compared with stream bank soil (<2 mm) and the <75-μm fraction of stream bank soils suggest that catchment soils contain more P, are more P saturated and are significantly more likely to deliver FRP and TP in excess of water quality targets than stream bank soils. Stream bank soils are much more likely to retain P than contribute P to streams, and the in-stream mixing of FRP from the landscape with particulates from stream banks or stream beds is a potential mechanism to explain the change in P form from hillslopes (96 to 99 % FRP) to large catchments (40 % FRP). When considered in the context of previous work reporting that riparian buffers were ineffective for P management in this environment, these studies reinforce the notion that (1) riparian buffers are unlikely to provide fit-for-purpose P management in catchments with sandy soils, (2) most P delivered to streams in sandy soil catchments is FRP and travels via subsurface and leaching pathways and (3) large catchment-scale water quality measurements are not good indicators of hillslope P mobilisation and transport processes.

  4. Fire Detections and Fire Radiative Power Intercomparison Using Multiple Sensor Products over a Predominantly Gas Flaring Region

    NASA Astrophysics Data System (ADS)

    Sharma, A.; Wang, J.

    2014-12-01

    Gas flaring is a global environmental hazard severely impacting climate, economy and public health. The associated emissions are frequently unreported and have large uncertainties. Prior studies have established a direct relationship between radiative energy released from fires and the biomass burned, making fire radiative power (FRP), i.e., the rate of radiative energy release, an important proxy to characterize emissions. In this study fire properties from four different satellite products were obtained over a 10⁰ x 10⁰ gas flaring region in Russia for all days of May 2013. The target area is part of Russia's biggest gas flaring region, Khanty-Mansiysk autonomous okrug. The objective of the study is to investigate the consistency of fire detections, FRP retrievals and effects of gridding FRP data from the region on a uniform grid. The four products used were: MODIS Terra level2 thermal anomalies (MOD14), MODIS Aqua level2 thermal anomalies (MYD14), VIIRS Active fire product and a recent NOAA Nightfire product. 1 km nominal resolution FRP from MOD14 AND MYD14, subpixel radiant heat (RH) from NOAA Nightfire product and fire detections from all four products were recorded on a 0.25⁰ x 0.25⁰ grid on a daily basis. Results revealed the Nightfire product had maximum detections, almost six times the number of detections by other products, mainly because of the use of M10 (1.6 µm) band as their primary detection band. The M10 band is highly efficient in identifying radiant emissions from hot sources during night-time. The correlation (after omitting outliers) between gridded NOAA Nightfire RH and corresponding MOD14 FRP and MYD14 FRP gave a moderate regression value, with MODIS FRP being mostly higher than RH. As an extension to this work, a comprehensive study for a larger temporal domain also incorporating viewing geometries and cloud cover would advance our understanding of flare detections and associated FRP retrievals not just for the target region but also gas flaring regions globally.

  5. Candida albicans importance to denture wearers. A literature review.

    PubMed

    Gleiznys, Alvydas; Zdanavičienė, Eglė; Žilinskas, Juozas

    2015-01-01

    Opportunistic oral fungal infections have spred, especially in denture wearers. Denture stomatitis is a common inflammatory reaction, multifactorial etiology, which is usually associated with Candida species, particularly Candida albicans, due to its high virulence, ability to adhere and form biofilms on oral cavity tissues and denture surfaces. This article highlights the pathogenesis, clinical presentation, and management strategies of Candida-associated denture stomatitis commonly encountered in dental practice.

  6. The effect of various factors on the masticatory performance of removable denture wearer

    NASA Astrophysics Data System (ADS)

    Pratama, S.; Koesmaningati, H.; Kusdhany, L. S.

    2017-08-01

    An individual’s masticatory performance concerns his/her ability to break down food in order to facilitate digestion, and it therefore plays an important role in nutrition. Removable dentures are used to rehabilitate a loss of teeth, which could jeopardize masticatory performance. Further, there exist various other factors that can affect masticatory performance. The objective of this research is to analyze the relationship between various factors and masticatory performance. Thirty-four removable denture wearers (full dentures, single complete dentures, or partial dentures) participated in a cross-sectional study of masticatory performance using color-changeable chewing gum (Masticatory Performance Evaluating Gum Xylitol®). The volume of saliva was evaluated using measuring cups, while the residual ridge heights were measured using a modified mouth mirror no. 3 with metric measurements. The residual ridge height and removable-denture-wearing experience exhibited a significant relationship with masticatory performance. However, age, gender, saliva volume, denture type, and the number and location of the missing teeth did not have a statistically significant association with masticatory performance. The residual ridge height influences the masticatory performance of removable denture wearers, since the greater the ridge height, the better the performance. The experience of using dentures also has a statistically significant influence on masticatory performance.

  7. Elderly complete denture wearers: a social approach to tooth loss.

    PubMed

    Papadaki, Eftychia; Anastassiadou, Vassiliki

    2012-06-01

    To correlate emotional reactions to tooth loss with denture satisfaction attributes in elderly complete denture wearers. Total tooth loss is a serious life event, and poor oral health has an impact on daily life. Edentulism treated by rehabilitation with dentures can have a positive effect on patients' self-image and social behaviour. A group of 80 edentulous subjects undergoing routine prosthetic care in a Greek Department of Prosthetic Dentistry were interviewed using two structured questionnaires. The first questionnaire explored reactions to tooth loss, whereas the second measured their subjective experience of complete dentures. The responses to both questionnaires were compared using the statistical package SPSS v.17. The results showed significant correlation between aspects of tooth loss experience and complete denture satisfaction. Despite the fact that a substantial proportion of patients were satisfied with their complete dentures, some patients experienced increased social and psychological problems related to their edentulousness and the wearing of complete dentures. The aesthetic and functional aspects of complete dentures affected both patients' social behaviour and self-confidence. Total tooth loss was not only reflected in patient's social behaviour and self-image, but it had a complex and multifaceted impact on satisfaction from complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  8. Improved Bond Equations for Fiber-Reinforced Polymer Bars in Concrete

    PubMed Central

    Pour, Sadaf Moallemi; Alam, M. Shahria; Milani, Abbas S.

    2016-01-01

    This paper explores a set of new equations to predict the bond strength between fiber reinforced polymer (FRP) rebar and concrete. The proposed equations are based on a comprehensive statistical analysis and existing experimental results in the literature. Namely, the most effective parameters on bond behavior of FRP concrete were first identified by applying a factorial analysis on a part of the available database. Then the database that contains 250 pullout tests were divided into four groups based on the concrete compressive strength and the rebar surface. Afterward, nonlinear regression analysis was performed for each study group in order to determine the bond equations. The results show that the proposed equations can predict bond strengths more accurately compared to the other previously reported models. PMID:28773859

  9. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment.

    PubMed

    Kaur, Harsimran; Datta, Kusum

    2015-01-01

    To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA) were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P) and rest 80 to heat-cured resilient liner (Molloplast B). Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm) in the space provided by a spacer of 3 mm, thermocycled (5-55°C) for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student's t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B) increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  10. Five-year multicenter study of magnetic attachments used for natural overdenture abutments.

    PubMed

    Gonda, T; Yang, T C; Maeda, Y

    2013-04-01

    The purpose of this study was to examine a longitudinal clinical performance of magnetic attachments used for natural overdenture abutments. The study included 131 patients who had used removable prostheses (complete overdentures 31%, partial dentures 69%) more than 5 years (40-90 years old) with 211 magnetic attachments on natural abutments (Magfit 400 or 600; Aichi Steel co., Aichi, Japan) treated in 15 clinics using a standardized protocol. Analyses were performed on the degree of patient satisfaction regarding retention, complications of magnets (corrosion, detachment from denture base), abutments (pain during mastication, periodontal pocket formation, inflammation, mobility), and dentures (fracture etc.). Ninety-seven percent of patients were satisfied with the retention and stability of their dentures. No corrosion of magnet was observed, and 19 magnets were detached. Most frequent complication of abutments was periodontal pocket formation (52%), followed by the inflammation (29%), increase in mobility (27%) and pain (4%). Magnetic attachment on natural tooth abutments provided a viable and long-term treatment option. © 2013 Blackwell Publishing Ltd.

  11. 2012 Federal Radionavigation Plan.

    DOT National Transportation Integrated Search

    2012-01-01

    The Federal Radionavigation Plan (FRP) reflects the official positioning, : navigation, and timing (PNT) policy and planning for the Federal : Government. Within the construct of the National PNT Architecture, the : FRP covers both terrestrial- and s...

  12. 2014 Federal Radionavigation Plan.

    DOT National Transportation Integrated Search

    2015-01-01

    The Federal Radionavigation Plan (FRP) reflects the official positioning, : navigation, and timing (PNT) policy and planning for the Federal : Government. Within the construct of the National PNT Architecture, the : FRP covers both terrestrial- and s...

  13. Development of a Contemporary Animal Model of Candida albicans-Associated Denture Stomatitis Using a Novel Intraoral Denture System

    PubMed Central

    Johnson, Clorinda C.; Yu, Alika; Lee, Heeje; Fidel, Paul L.

    2012-01-01

    Denture stomatitis (DS) is a fungal infection characterized by inflammation of the oral mucosa in direct contact with the denture and affects up to 50% of denture wearers. Despite the prevalence, very little is known about the role of fungal or host factors that contribute to pathogenesis. Recently, we developed a novel intraoral denture system for rodent research. This denture system consists of custom-fitted fixed and removable parts to allow repeated sampling and longitudinal studies. The purpose of this study was to use this denture system to develop a clinically relevant animal model of DS. To establish DS, rats were inoculated with pelleted Candida albicans, which resulted in sustained colonization of the denture and palate for 8 weeks postinoculation. Biofilm formation on the denture was observed by week 4 and on the palate by week 6 postinoculation. Rats were monitored for clinical signs of disease by assigning a clinical score after macroscopic examination of the palate tissue according to Newton's method. By week 4 postinoculation, the majority of inoculated rats with dentures exhibited a clinical score of 1 (pinpoint erythema). By week 6 and week 8 postinoculation, increasing percentages of rats exhibited a clinical score of 2 (diffuse erythema/edema). Histological analysis of palate tissue demonstrated progressively increasing inflammatory cell recruitment throughout the time course of the infection. Palatal biofilm formation was commensurate with development of palatal erythema, which suggests a role for biofilm in the inflammatory response. PMID:22392931

  14. In Vitro Wear Resistance of Nano-Hybrid Composite Denture Teeth.

    PubMed

    Munshi, Nabeel; Rosenblum, Marc; Jiang, Shuying; Flinton, Robert

    2017-04-01

    To evaluate the wear resistance of nano-hybrid composite denture teeth as compared to two commonly used denture teeth: interpenetrating polymer network (IPN) and double crosslinking polymethylmethacrylate (PMMA) denture teeth. 18 styli and 18 disk specimens were prepared from the three denture tooth materials: nano-hybrid composite, IPN, and double crosslinking PMMA. The specimens were mounted in a two-body wear testing machine to simulate chewing in the complete denture. The amount of wear from the styli specimens were measured before and after using a digital micrometer, and the depth of the wear track from the disk specimens was measured using a noncontact 3D optical profilometer. The total wear from each denture tooth group was compared using one-way ANOVA with a 0.05 significance level. A Tukey post hoc test was used to determine differences between the three groups. The mean total wear in the nano-hybrid composite teeth group was 1.16 mm, SD = 0.5 mm, statistically significantly higher (p ≤ 0.0001) than the IPN (mean = 0.13 mm, SD = 0.05) and double crosslinking PMMA tooth groups (mean = 0.31 mm, SD = 0.19). There was no statistically significant difference between IPN denture teeth and double crosslinking PMMA denture teeth in the amount of wear. Nano-hybrid composite denture teeth exhibited statistically significantly more wear than the IPN and double crosslinking PMMA denture teeth. © 2015 by the American College of Prosthodontists.

  15. Evaluation of mechanical and thermal properties of commonly used denture base resins.

    PubMed

    Phoenix, Rodney D; Mansueto, Michael A; Ackerman, Neal A; Jones, Robert E

    2004-03-01

    The purpose of this investigation was to evaluate and compare the mechanical and thermal properties of 6 commonly used polymethyl methacrylate denture base resins. Sorption, solubility, color stability, adaptation, flexural stiffness, and hardness were assessed to determine compliance with ADA Specification No. 12. Thermal assessments were performed using differential scanning calorimetry and dynamic mechanical analysis. Results were assessed using statistical and observational analyses. All materials satisfied ADA requirements for sorption, solubility, and color stability. Adaptation testing indicated that microwave-activated systems provided better adaptation to associated casts than conventional heat-activated resins. According to flexural testing results, microwaveable resins were relatively stiff, while rubber-modified resins were more flexible. Differential scanning calorimetry indicated that microwave-activated systems were more completely polymerized than conventional heat-activated materials. The microwaveable resins displayed better adaptation, greater stiffness, and greater surface hardness than other denture base resins included in this investigation. Elastomeric toughening agents yielded decreased stiffness, decreased surface hardness, and decreased glass transition temperatures.

  16. Color change in acrylic denture base resin reinforced with wire mesh and glass cloth.

    PubMed

    Kanie, Takahito; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji

    2003-12-01

    In this study, the L*a*b* color system as a color system and light transmittance of the denture base resin reinforced with wire mesh and glass cloth were measured, and the color difference (deltaE*ab) was calculated using L*, a* and b* values which were measured both on a white calibration plate and on a null background. The thicknesses of test specimens, which were reinforced with wire mesh and glass cloth 0.5 and 1.0 mm below the surface, were 3 and 5 mm. L*, a* and b* values of wire mesh reinforcing specimens decreased in comparison with the non-reinforcing specimens (p<0.05). L* values of glass cloth-reinforcing specimens increased compared with the non-reinforcing specimens (p<0.05). The glass cloth is an effective reinforcing material and an aesthetically important property of denture base resin, since wire mesh makes the resin appear darker with the background condition greatly altering the color, while glass cloth makes the resin lighter.

  17. Effect of repair resin type and surface treatment on the repair strength of polyamide denture base resin.

    PubMed

    Gundogdu, Mustafa; Yanikoglu, Nuran; Bayindir, Funda; Ciftci, Hilal

    2015-01-01

    The purpose of the present study was to evaluate the effects of different repair resins and surface treatments on the repair strength of a polyamide denture base material. Polyamide resin specimens were prepared and divided into nine groups according to the surface treatments and repair materials. The flexural strengths were measured with a 3-point bending test. Data were analyzed with a 2-way analysis of variance, and the post-hoc Tukey test (α=0.05). The effects of the surface treatments on the surface of the polyamide resin were examined using scanning electron microscopy. The repair resins and surface treatments significantly affected the repair strength of the polyamide denture base material (p<0.05); however, no significant differences were observed interaction between the factors (p>0.05). The flexural strength of the specimens repaired with the polyamide resin was significantly higher than that of those repaired with the heat-polymerized and autopolymerizing acrylic resins.

  18. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  19. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  20. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  1. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  2. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  3. Influence of the mechanical properties of resilient denture liners on the retention of overdenture attachments.

    PubMed

    Kubo, Keitaro; Koike, Takashi; Ueda, Takayuki; Sakurai, Kaoru

    2018-03-15

    Information is lacking about the selection criteria for silicone resilient denture liners applied as a matrix material for attachments on overdentures. The purpose of this in vitro study was to investigate the mechanical properties of silicone resilient denture liners and their influence on the initial retention force of overdenture attachments and the reduction in retention force over time. Nine types of silicone resilient denture liner were injected and fixed to the matrix section of an experimental denture base. They were then fitted to an epoxy resin model that simulated the residual ridge with a patrix ball attachment (n=10). The retention force of the denture was measured with a digital force gauge, and the maximum force of traction (N) was regarded as the initial retention force. The retention force reduction (N) after repeated insertion and removal (n=5) was calculated by subtracting the retention force after 3348 cycles (3-year simulated insertion and removal) from the initial retention force. The intaglio of the matrix was observed with a scanning electron microscope (SEM) before and after the 3348 cycles. Four mechanical properties (hardness, strain-in-compression, tensile strength, and arithmetic mean roughness) of the resilient denture liners were measured. One-way ANOVA of the initial retention force of each lining material was performed, followed by the Scheffe test (α=.05). Pearson correlation analysis was used (α=.05) to analyze correlations of the initial retention force with the retention force reduction after insertion and removal and the mechanical properties of each material. Multiple regression analysis with the stepwise method extracted the initial retention force and the retention force reduction as dependent variables, and the resilient denture liner mechanical properties as explanatory variables (α=.05). The initial retention force of the resilient denture liners was 1.3 to 5.4 N. Multiple comparisons showed significant differences in some groups (P<.05). The retention force reduction of the resilient denture liners was 0.2 to 1.9 N. Multiple regression analysis with the stepwise method extracted hardness and strain-in-compression as explanatory variables for the initial retention force and the retention force reduction. Within the limitations of this in vitro study, we found that hardness influenced the initial retention force of the overdenture, and that strain-in-compression influenced the retention force reduction in the 3-year simulation. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Complete denture biofilm after brushing with specific denture paste, neutral soap and artificial saliva.

    PubMed

    Paranhos, Helena de Freitas Oliveira; Salles, Antônio Eduardo Sparça; Macedo, Leandro Dorigan de; Silva-Lovato, Cláudia Helena da; Pagnano, Valéria Oliveira; Watanabe, Evandro

    2013-01-01

    This study compared the levels of biofilm in maxillary and mandibular complete dentures and evaluated the number of colony-forming units (cfu) of yeasts, after using auxiliary brushing agents and artificial saliva. Twenty-three denture wearers with hyposalivation and xerostomia were instructed to brush the dentures 3 times a day during 3 weeks with the following products: Corega Brite denture dentifrice, neutral liquid soap, Corega Brite combined with Oral Balance (artificial saliva) or tap water. For biofilm quantification, the internal surfaces of the dentures were disclosed, photographed and measured using a software. For microbiological analysis, the biofilm was scrapped off, and the harvested material was diluted, sown in CHROMagar™ Candida and incubated at 37°C for 48 h. Data were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05). Mandibular dentures presented a mean biofilm percentage (µ=26.90 ± 21.10) significantly greater than the maxillary ones (µ=18.0 ± 15.0) (p<0.05). Brushing using Corega Brite combined with Oral Balance (µ=15.87 ± 18.47) was more effective (p<0.05) than using the denture dentifrice (µ=19.47 ± 17.24), neutral soap (µ=23.90 ± 18.63) or tap water (control; µ=32.50 ± 20.68). For the microbiological analysis, the chi-square test did not indicate significant difference between the hygiene products for either type of denture. The more frequently isolated species of yeasts were C. albicans, C. tropicalis and C. glabrata. In conclusion, mandibular dentures had more biofilm formation than maxillary ones. Denture brushing with Corega Brite dentifrice combined with the use of Oral Balance was the most effective method for reduction of biofilm levels, but the use of products did not show difference in yeast cfu counts.

  5. 2017 Federal Radionavigation Plan.

    DOT National Transportation Integrated Search

    2017-01-01

    The Federal Radionavigation Plan (FRP) reflects the official positioning, navigation, and timing (PNT) policy and planning for the Federal Government. Within the construct of the National PNT Architecture, the FRP covers both terrestrial- and space-b...

  6. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    PubMed

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  7. Flexural behaviour of RCC beams with externally bonded FRP

    NASA Astrophysics Data System (ADS)

    Vignesh, S. Arun; Sumathi, A.; Saravana Raja Mohan, K.

    2017-07-01

    The increasing use of carbon and glass fibre reinforced polymer (FRP) sheets for strengthening existing reinforced concrete beams has generated considerable interest in understanding the behavior of the FRP sheets when subjected to bending. The study on flexure includes various parameters like percentage of increase in strength of the member due to the externally bonded Fiber reinforced polymer, examining the crack patterns, reasons of debonding of the fibre from the structure, scaling, convenience of using the fibres, cost effectiveness etc. The present work aims to study experimentally about the reasons behind the failure due to flexure of an EB-FRP concrete beam by studying the various parameters. Deflection control may become as important as flexural strength for the design of FRPreinforced concrete structures. A numerical model is created using FEM software and the results are compared with that of the experiment.

  8. Detailed Evaluation of MODIS Fire Radiative Power Measurements

    NASA Technical Reports Server (NTRS)

    Ichoku, Charles

    2010-01-01

    Satellite remote sensing is providing us tremendous opportunities to measure the fire radiative energy (FRE) release rate or power (FRP) from open biomass burning, which affects many vegetated regions of the world on a seasonal basis. Knowledge of the biomass burning characteristics and emission source strengths of different (particulate and gaseous) smoke constituents is one of the principal ingredients upon which the assessment, modeling, and forecasting of their distribution and impacts depend. This knowledge can be gained through accurate measurement of FRP, which has been shown to have a direct relationship with the rates of biomass consumption and emissions of major smoke constituents. Over the last decade or so, FRP has been routinely measured from space by both the MODIS sensors aboard the polar orbiting Terra and Aqua satellites, and the SEVIRI sensor aboard the Meteosat Second Generation (MSG) geostationary satellite. During the last few years, FRP has been gaining recognition as an important parameter for facilitating the development of various scientific studies relating to the quantitative characterization of biomass burning and their emissions. Therefore, we are conducting a detailed analysis of the FRP products from MODIS to characterize the uncertainties associated with them, such as those due to the MODIS bow-tie effects and other factors, in order to establish their error budget for use in scientific research and applications. In this presentation, we will show preliminary results of the MODIS FRP data analysis, including comparisons with airborne measurements.

  9. Numerical Study on Deflection Behaviour of Concrete Beams Reinforced with GFRP Bars

    NASA Astrophysics Data System (ADS)

    Mohamed, Osama A.; Khattab, Rania; Hawat, Waddah Al

    2017-10-01

    Fiber-Reinforced Polymer (FRP) bars are gaining popularity as sustainable alternatives to conventional reinforcing steel bars in reinforced concrete applications. The production of FRP bars has lower environmental impact compared to steel reinforcing bars. In addition, the non-corroding FRP materials can potentially decrease the cost or need for maintenance of reinforced concrete structural elements, especially in harsh environmental conditions that can impact both concrete and reinforcement. FRP bars offer additional favourable properties including high tensile strength and low unit weight. However, the mechanical properties of FRP bars can lead to large crack widths and deflections. The objective of this study is to investigate the deflection behaviour of concrete beams reinforced with Glass FRP (GFRP) bars as a longitudinal main reinforcement. Six concrete beams reinforced with GFRP bars were modelled using the finite element computer program ANSYS. The main variable considered in the study is the reinforcement ratio. The deflection equations in current North American codes including ACI 440.1R-06, ACI 440.1R-15 and CSA S806-12 are used to compute deflections, and these are compared to numerical results. It was concluded in this paper that deflections predicted by ACI 440.1R-06 equations are lower than the numerical analysis results while ACI 440.1R-15 is in agreement with numerical analysis with tendency to be conservative. The values of deflections estimated by CSA S806-12 formulas are consistent with results of numerical analysis.

  10. Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars

    NASA Astrophysics Data System (ADS)

    Mohamed, Osama A.; Khattab, Rania

    2017-10-01

    Using Fibre Reinforced Polymer (FRP) bars to reinforce two-way concrete slabs can extend the service life, reduce maintenance cost and improve-life cycle cost efficiency. FRP reinforcing bars are more environmentally friendly alternatives to traditional reinforcing steel. Shear behaviour of reinforced concrete structural members is a complex phenomenon that relies on the development of internal load-carrying mechanisms, the magnitude and combination of which is still a subject of research. Many building codes and design standards provide design formulas for estimation of punching shear capacity of FRP reinforced flat slabs. Building code formulas take into account the effects of the axial stiffness of main reinforcement bars, the ratio of the perimeter of the critical section to the slab effective depth, and the slab thickness on the punching shear capacity of two-way slabs reinforced with FRP bars or grids. The goal of this paper is to compare experimental data published in the literature to the equations offered by building codes for the estimation of punching shear capacity of concrete flat slabs reinforced with FRP bars. Emphasis in this paper is on two North American codes, namely, ACI 440.1R-15 and CSA S806-12. The experimental data covered in this paper include flat slabs reinforced with GFRP, BFRP, and CFRP bars. Both ACI 440.1R-15 and CSA S806-12 are shown to be in good agreement with test results in terms of predicting the punching shear capacity.

  11. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  12. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  13. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  14. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  15. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  16. Evaluating the efficiency of humic acid to remove micro-organisms from denture base material.

    PubMed

    Meriç, Gökçe; Güvenir, Meryem; Süer, Kaya

    2016-09-01

    To evaluate the efficiency of humic acid substances on removing micro-organisms from denture base materials. Old denture wearer needs effective, easy-use and safe denture-cleaning material. Square-shaped, heat-polymerised acrylic resin specimens (n = 550) were prepared and divided into five groups (n = 110 for each) corresponding to the microbial contamination (Candida albicans, Staphylococcus aureus, Bacillus cereus, Enterococcus faecalis, Pseudomonas aeruginosa). Contaminated specimens were randomly assigned to the application of five different denture-cleaning agents as follows (n = 20 for each): Kloroben, Corsodyl, Steradent, Corega, experimental solution with humic acid. Ten specimens were assessed as an experimental control carried out simultaneously for the treatment groups for each micro-organism. It was divided into two groups: negative control and positive control (n = 5 for each). All acrylic specimens were incubated 37°C for 24 h (for bacterial strains) and 37°C for 48 h (for yeast strains). After incubation period, all brain-heart infusion broths (BHI) which contain disinfectant acrylic specimens were cultured on 5% sheep blood agar (for bacteria) and Sabouraud dextrose agar (SDA) for yeast using loop. The numbers of colony-forming units per millilitre (CFU/ml) were calculated. The results were analysed by Mann-Whitney U-test and Kruskal-Wallis tests (p = 0.05). Corsodyl and Kloroben completely eliminated the adherence of all investigated micro-organisms (100%) and showed the highest removal activity compared with other cleaning agents (p < 0.05). There was no statistically significant difference between Corsodyl and Kloroben (p ≥ 0.05), and there was no statistically significant difference between Corega, Steradent and experimental solution (p ≥ 0.05). Humic acid could be used as an alternative 'natural' solution for denture-cleaning agent. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  17. Present status of titanium removable dentures--a review of the literature.

    PubMed

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  18. Effectiveness of a Chlorhexidine Digluconate 0.12% and Cetylpyridinium Chloride 0.05% Solution in eliminating Candida albicans Colonizing Dentures: A Randomized Clinical in vivo Study.

    PubMed

    Aoun, Georges; Cassia, Antoine; Berberi, Antoine

    2015-06-01

    Effective denture hygiene is important for patients suffering from denture stomatitis (DS). This study aimed to evaluate the efficacy of a solution containing 0.12% chlorhexidine (CHX) digluconate and 0.05% cetylpyridinium chloride (CPC) in eliminating Candida albicans colonizing dentures. Forty denture wearers (11 men, 29 women; age range 40 to 80 years) with clinical evidence of DS were randomly divided into two groups, one test and one control. The dentures of the test group were treated by immersion in a solution of 0.12% CHX and 0.05% CPC while those of the control group were immersed in distilled water. Swabs were collected from the fitting surfaces of the upper dentures prior and post cleaner use and examined mycologically. Reduction in the number of colony-forming units (CFU) of Candida albicans after immersion of the dentures in a solution of 0.12% CHX and 0.05% CPC was significantly greater than that of the control group. A solution of 0.12% CHX and 0.05% CPC tested as a product of disinfection of the acrylic dentures showed significant results after immersion of 8 night hours for 4 days.

  19. Silver distribution and release from an antimicrobial denture base resin containing silver colloidal nanoparticles.

    PubMed

    Monteiro, Douglas Roberto; Gorup, Luiz Fernando; Takamiya, Aline Satie; de Camargo, Emerson Rodrigues; Filho, Adhemar Colla Ruvolo; Barbosa, Debora Barros

    2012-01-01

    The aim of this study was to evaluate a denture base resin containing silver colloidal nanoparticles through morphological analysis to check the distribution and dispersion of these particles in the polymer and by testing the silver release in deionized water at different time periods. A Lucitone 550 denture resin was used, and silver nanoparticles were synthesized by reduction of silver nitrate with sodium citrate. The acrylic resin was prepared in accordance with the manufacturers' instructions, and silver nanoparticle suspension was added to the acrylic resin monomer in different concentrations (0.05, 0.5, and 5 vol% silver colloidal). Controls devoid of silver nanoparticles were included. The specimens were stored in deionized water at 37°C for 7, 15, 30, 60, and 120 days, and each solution was analyzed using atomic absorption spectroscopy. Silver was not detected in deionized water regardless of the silver nanoparticles added to the resin and of the storage period. Micrographs showed that with lower concentrations, the distribution of silver nanoparticles was reduced, whereas their dispersion was improved in the polymer. Moreover, after 120 days of storage, nanoparticles were mainly located on the surface of the nanocomposite specimens. Incorporation of silver nanoparticles in the acrylic resin was evidenced. Moreover, silver was not detected by the detection limit of the atomic absorption spectrophotometer used in this study, even after 120 days of storage in deionized water. Silver nanoparticles are incorporated in the PMMA denture resin to attain an effective antimicrobial material to help control common infections involving oral mucosal tissues in complete denture wearers. © 2011 by the American College of Prosthodontists.

  20. Heat-cured acrylic resin versus light-activated resin: a patient, professional and technician-based evaluation of mandibular implant-supported overdentures.

    PubMed

    Asal, S A; Al-AlShiekh, H M

    2017-12-01

    Although light-activated resins (Eclipse) have been reported to possess superior physical and mechanical properties compared with the heat-cured acrylic resins (Lucitone-199), a few studies have compared overdentures with a locator attachment constructed from heat-cured acrylic resins with those constructed from light-activated resins. This clinical study was designed to compare the performance of a mandibular implant-supported overdenture constructed from a heat-cured acrylic resin (Lucitone-199) with that of an overdenture constructed from a light-activated resin (Eclipse). Ten participants received two identical mandibular implant-retained overdentures (Lucitone-199 and Eclipse) opposing one maxillary denture in a random order. Each mandibular overdenture was delivered and worn for 6 months, and two weeks of rest was advised between wears to minimize any carryover effects. Three questionnaires were devised. The first questionnaire (patient evaluation) focused on evaluating different aspects of the denture and overall satisfaction. The second questionnaire (professional dentist evaluation) was based on a clinical evaluation of soft tissues, complications, and the applied technique. The third questionnaire (technician evaluation) involved ranking the different manufacturing steps of the denture and overall preferences. The obtained data was statistically analyzed using an independent sample t-test and the Wilcoxon rank-sum test. The clinician and technician preferred the Eclipse dentures because of their technical aspects, whereas the patients preferred the Lucitone-199 dentures for their aesthetic properties. Implant-supported overdentures constructed from a heat-cured acrylic resin showed superior aesthetics and had a better odor compared with those constructed from a light-cured resin.

  1. Development of a self-stressing NiTiNb shape memory alloy (SMA)/fiber reinforced polymer (FRP) patch

    NASA Astrophysics Data System (ADS)

    El-Tahan, M.; Dawood, M.; Song, G.

    2015-06-01

    The objective of this research is to develop a self-stressing patch using a combination of shape memory alloys (SMAs) and fiber reinforced polymer (FRP) composites. Prestressed carbon FRP patches are emerging as a promising alternative to traditional methods to repair cracked steel structures and civil infrastructure. However, prestressing these patches typically requires heavy and complex fixtures, which is impractical in many applications. This paper presents a new approach in which the prestressing force is applied by restraining the shape memory effect of NiTiNb SMA wires. The wires are subsequently embedded in an FRP overlay patch. This method overcomes the practical challenges associated with conventional prestressing. This paper presents the conceptual development of the self-stressing patch with the support of experimental observations. The bond between the SMA wires and the FRP is evaluated using pull-out tests. The paper concludes with an experimental study that evaluates the patch response during activation subsequent monotonic tensile loading. The results demonstrate that the self-stressing patch with NiTiNb SMA is capable of generating a significant prestressing force with minimal tool and labor requirements.

  2. Design and fabrication of complete dentures using CAD/CAM technology

    PubMed Central

    Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686

  3. Research notes : modeling a composite reinforced bridge.

    DOT National Transportation Integrated Search

    2001-06-01

    In 1998, Oregon Department of Transportation (ODOT) used fiber reinforced polymer (FRP) composites to strengthen the historic Horsetail Falls Bridge. Because this was the first experience with FRP composites, research was conducted to verify that the...

  4. Smart FRP Composite Sandwich Bridge Decks in Cold Regions

    DOT National Transportation Integrated Search

    2011-07-01

    In this study, new and integrated Smart honeycomb Fiber-Reinforced Polymer (S-FRP) : sandwich materials for various transportation construction applications, with particular emphasis : on highway bridge decks in cold regions, were developed and teste...

  5. Influence of clinical baseline findings on the survival of 2 post systems: a randomized clinical trial.

    PubMed

    Schmitter, Marc; Rammelsberg, Peter; Gabbert, Olaf; Ohlmann, Brigitte

    2007-01-01

    The aim of this prospective randomized controlled trial was to evaluate the influence of clinical baseline characteristics on the survival of 2 post systems. One hundred patients needing a post were included. Half the patients received a glass fiber-reinforced post (FRP), and the other half received metal screw posts (MSP). The posts were assigned randomly. In addition to demographic data, the following parameters were recorded: type of tooth (incisor/canine versus molar/premolar), length of the post in relation to root length (percentage), extent of coronal tooth destruction (percentage), ferrule height (in millimeters), type of restoration (fixed or removable partial denture), and presence of antagonistic contacts (yes/no). After at least 1 year (mean: 13.84 months), the patients were recalled. Statistical analysis was performed using the log-rank test and Cox regression analysis. The survival rate of FRPs was 93.5%. In the MSP group, the survival rate was significantly lower (75.6%; log-rank test, P = .049). Additionally, the metal posts were associated with more unfavorable complications, for example, root fracture. The type of the tooth and the degree of coronal tooth destruction influenced the survival of MSPs, whereas no influence of these variables could be seen for FRPs. FRPs are superior to MSPs with respect to short-term clinical performance. Especially for MSPs, clinical survival depends on several variables.

  6. An in vitro study to compare the transverse strength of thermopressed and conventional compression-molded polymethylmethacrylate polymers.

    PubMed

    Raut, Anjana; Rao, Polsani Laxman; Vikas, B V J; Ravindranath, T; Paradkar, Archana; Malakondaiah, G

    2013-01-01

    Acrylic resins have been in the center stage of Prosthodontics for more than half a century. The flexural fatigue failure of denture base materials is the primary mode of clinical failure. Hence there is a need for superior physical and mechanical properties. This in vitro study compared the transverse strength of specimens of thermopressed injection-molded and conventional compression-molded polymethylmethacrylate polymers and examined the morphology and microstructure of fractured acrylic specimens. The following denture base resins were examined: Brecrystal (Thermopressed injection-molded, modified polymethylmethacrylate) and Pyrax (compression molded, control group). Specimens of each material were tested according to the American Society for Testing and Materials standard D790-03 for flexural strength testing of reinforced plastics and subsequently examined under SEM. The data was analyzed with Student unpaired t test. Flexural strength of Brecrystal (82.08 ± 1.27 MPa) was significantly higher than Pyrax (72.76 ± 0.97 MPa). The tested denture base materials fulfilled the requirements regarding flexural strength (>65 MPa). The scanning electron microscopy image of Brecrystal revealed a ductile fracture with crazing. The fracture pattern of control group specimens exhibited poorly defined crystallographic planes with a high degree of disorganization. Flexural strength of Brecrystal was significantly higher than the control group. Brecrystal showed a higher mean transverse strength value of 82.08 ± 1.27 MPa and a more homogenous pattern at microscopic level. Based on flexural strength properties and handling characteristics, Brecrystal may prove to be an useful alternative to conventional denture base resins.

  7. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  8. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  9. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  10. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  11. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  12. 21 CFR 872.3530 - Mechanical denture cleaner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mechanical denture cleaner. 872.3530 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3530 Mechanical denture cleaner. (a) Identification. A mechanical denture cleaner is a device, usually AC-powered, that consists of a container for...

  13. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  14. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  15. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  16. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  17. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  18. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  19. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  20. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  1. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  2. An operational system for the assimilation of the satellite information on wild-land fires for the needs of air quality modelling and forecasting

    NASA Astrophysics Data System (ADS)

    Sofiev, M.; Vankevich, R.; Lotjonen, M.; Prank, M.; Petukhov, V.; Ermakova, T.; Koskinen, J.; Kukkonen, J.

    2009-09-01

    This paper investigates a potential of two remotely sensed wild-land fire characteristics: 4-μm Brightness Temperature Anomaly (TA) and Fire Radiative Power (FRP) for the needs of operational chemical transport modelling and short-term forecasting of atmospheric composition and air quality. The treatments of the TA and FRP data are presented and a methodology for evaluating the emission fluxes of primary aerosols (PM2.5 and total PM) is described. The method does not include the complicated analysis of vegetation state, fuel load, burning efficiency and related factors, which are uncertain but inevitably involved in approaches based on burnt-area scars or similar products. The core of the current methodology is based on the empirical emission factors that are used to convert the observed temperature anomalies and fire radiative powers into emission fluxes. These factors have been derived from the analysis of several fire episodes in Europe (28.4-5.5.2006, 15.8-25.8.2006 and in August 2008). These episodes were characterised by: (i) well-identified FRP and TA values, and (ii) available ground-based observations of aerosol concentrations, and optical thickness for the regions where the contribution of the fire smoke to the concentrations of PM2.5 was dominant, in comparison with those of other pollution sources. The emission factors were determined separately for the forested and grassland areas; in case of mixed-type land use, an intermediate scaling was assumed. Despite significant differences between the TA and FRP methodologies, an accurate non-linear fitting was found between the predictions of these approaches. The agreement was comparatively weak only for small fires, for which the accuracy of both products is expected to be low. The applications of the Fire Assimilation System (FAS) in combination with the dispersion model SILAM showed that both the TA and FRP products are suitable for the evaluation of the emission fluxes from wild-land fires. The fire-originated concentrations of aerosols (PM2.5, PM10, sulphates and nitrates) and AOD, as predicted by the SILAM model were mainly within a factor of 2-3 compared with the observations. The main challenges of the FAS improvement include refining of the emission factors globally, determination of the types of fires (smouldering vs flaming), evaluation of the injection heights of the plumes, and predicting the temporal evolution of fires.

  3. Effect of phosphate group addition on the properties of denture base resins

    PubMed Central

    Puri, Gaurav; Berzins, David W.; Dhuru, Virendra B.; Raj, Periathamby A.; Rambhia, Sameer K.; Dhir, Gunjan; Dentino, Andrew R.

    2009-01-01

    Statement of problem Acrylic resins are prone to microbial adherence, especially by Candida albicans. Surface-charged resins alter the ionic interaction between the denture resin and Candida hyphae, and these resins are being developed as a means to reduce microbial colonization on the denture surface. Purpose The purpose of this study was to investigate the physical and mechanical properties of phosphate-containing polymethyl methacrylate resins for their suitability as a denture material. Material and methods Using PMMA with cross-linker (Lucitone 199) as a control, 4 experimental groups containing various levels of phosphate with and without cross-linker were generated. The properties examined were impact strength, fracture toughness, wettability (contact angle), and resin bonding ability to denture teeth. Impact strength was tested in the Izod configuration (n=16), and fracture toughness (n=13) was measured using the single-edge notched bend test. Wettability was determined by calculating the contact angle of water on the material surface (n=12), while ISO 1567 was used for bonding ability (n=12). The data were analyzed by 1- and 2-way ANOVA (α=.05). Results A trend of increased hydrophilicity, as indicated by lower contact angle, was observed with increased concentrations of phosphate. With regard to the other properties, no significant differences were found when compared with the control acrylic resin. Conclusions No adverse physical effect due to the addition of a phosphate-containing monomer was found in the acrylic denture resins. Additional mechanical and physical properties, biocompatibility, and clinical efficacy studies are needed to confirm the in vivo anti-Candida activity of these novel resins. PMID:18922259

  4. Long-term efficacy of denture cleansers in preventing Candida spp. biofilm recolonization on liner surface.

    PubMed

    Vieira, Ana Paula Coelho; Senna, Plínio Mendes; Silva, Wander José da; Del Bel Cury, Altair Antoninha

    2010-01-01

    This study evaluated the long-term efficacy of denture cleansers against Candida spp. biofilm recolonization on liner surface. Specimens were fabricated of a poly(methyl methacrylate)-based denture liner and had their surface roughness evaluated at baseline and after cleansing treatments. C. albicans or C. glabrata biofilms were formed on liner surface for 48 h, and then the specimens were randomly assigned to one of cleaning treatments: two alkaline peroxides (soaking for 3 or 15 min), 0.5% sodium hypochlorite (10 min) or distilled water (control; 15 min). After the treatments, the specimens were sonicated to disrupt the biofilm, and residual cells were counted (cell/mL). Long-term effectiveness of the cleaning processes was determined by submitting a set of cleaned specimens to biofilm growth conditions for 48 h followed by estimation of cell counts. The topography of specimens after cleaning treatments was analyzed by SEM. Data were analyzed by ANOVA and Tukey's test (α; = 0.05). Results of cell count estimation showed significant differences in cleanliness among the treatments (p < 0.001), and it could be observed by SEM. However, no significant difference (p > 0.05) was observed among the Candida species regarding the recolonization condition. Alkaline denture cleansers showed similar cleaning performance and both differed from the control (p < 0.001). Sodium hypochlorite was the only treatment that removed biofilm efficiently, since no viable cells were found after its use. In conclusion, alkaline peroxide denture cleansers were not effective in removing Candida spp. biofilm from denture liner surfaces and preventing biofilm recolonization.

  5. Novel denture-cleaning system based on hydroxyl radical disinfection.

    PubMed

    Kanno, Taro; Nakamura, Keisuke; Ikai, Hiroyo; Hayashi, Eisei; Shirato, Midori; Mokudai, Takayuki; Iwasawa, Atsuo; Niwano, Yoshimi; Kohno, Masahiro; Sasaki, Keiichi

    2012-01-01

    The purpose of this study was to evaluate a new denture-cleaning device using hydroxyl radicals generated from photolysis of hydrogen peroxide (H2O2). Electron spin resonance analysis demonstrated that the yield of hydroxyl radicals increased with the concentration of H2O2 and light irradiation time. Staphylococcus aureus, Pseudomonas aeruginosa, and methicillin-resistant S aureus were killed within 10 minutes with a > 5-log reduction when treated with photolysis of 500 mM H2O2; Candida albicans was killed within 30 minutes with a > 4-log reduction with photolysis of 1,000 mM H2O2. The clinical test demonstrated that the device could effectively reduce microorganisms in denture plaque by approximately 7-log order within 20 minutes.

  6. An audit to assess the quality and efficiency of complete and partial dentures delivered by junior hospital staff.

    PubMed

    Kalsi, Harpoonam J; Wang, Yon Jon; Bavisha, Kalpesh; Bartlett, David

    2010-03-01

    The average number of visits for the construction of metal-based and acrylic dentures by junior hospital staff was 10 visits. Our hypothesis was that supervision would optimise the number of visits and reduce any need for remakes. The first audit cycle was retrospective and included all patients treated by SHOs in the Prosthodontics Department. The standard of care was compared to the British Society for the Study of Prosthetic Dentistry. The re-audit showed that the time taken to completion was reduced by 2 visits for both denture types and the average length of time was reduced from 31 weeks to 22 weeks. These improvements were directly related to improved supervision by senior staff.

  7. Quantitative Evaluation of MODIS Fire Radiative Power Measurement for Global Smoke Emissions Assessment

    NASA Technical Reports Server (NTRS)

    Ichoku, Charles; Ellison, Luke

    2011-01-01

    Satellite remote sensing is providing us tremendous opportunities to measure the fire radiative energy (FRE) release rate or power (FRP) from open biomass burning, which affects many vegetated regions of the world on a seasonal basis. Knowledge of the biomass burning characteristics and emission source strengths of different (particulate and gaseous) smoke constituents is one of the principal ingredients upon which the assessment, modeling, and forecasting of their distribution and impacts depend. This knowledge can be gained through accurate measurement of FRP, which has been shown to have a direct relationship with the rates of biomass consumption and emissions of major smoke constituents. Over the last decade or so, FRP has been routinely measured from space by both the MODIS sensors aboard the polar orbiting Terra and Aqua satellites, and the SEVIRI sensor aboard the Meteosat Second Generation (MSG) geostationary satellite. During the last few years, FRP has steadily gained increasing recognition as an important parameter for facilitating the development of various scientific studies and applications relating to the quantitative characterization of biomass burning and their emissions. To establish the scientific integrity of the FRP as a stable quantity that can be measured consistently across a variety of sensors and platforms, with the potential of being utilized to develop a unified long-term climate data record of fire activity and impacts, it needs to be thoroughly evaluated, calibrated, and validated. Therefore, we are conducting a detailed analysis of the FRP products from MODIS to evaluate the uncertainties associated with them, such as those due to the effects of satellite variable observation geometry and other factors, in order to establish their error budget for use in diverse scientific research and applications. In this presentation, we will show recent results of the MODIS FRP uncertainty analysis and error mitigation solutions, and demonstrate their implications for biomass burning emissions assessment.

  8. Smart FRP Composite Sandwich Bridge Decks in Cold Regions

    DOT National Transportation Integrated Search

    2011-07-01

    In this study, new and integrated Smart honeycomb Fiber-Reinforced Polymer (S-FRP) sandwich materials for various transportation construction applications, with particular emphasis on highway bridge decks in cold regions, were developed and tested. T...

  9. Response of No-Name Creek FRP Bridge to Local Weather

    DOT National Transportation Integrated Search

    2012-09-01

    Since 1996, over 30 Fiber Reinforced Polymer (FRP) composite bridges have been installed in the United States. Bridge : locations are in Kansas, Missouri, New York, Iowa, Colorado, West Virginia, Ohio, California, Idaho, Washington, Pennsylvania, : I...

  10. Evaluation of Eco-Efficiency and Performance of Retrofit Materials

    NASA Astrophysics Data System (ADS)

    Gopinath, Smitha; Rama Chandra Murthy, A.; Iyer, Nagesh R.; Kokila, S.

    2015-12-01

    In this work three materials namely Fiber Reinforced Polymer (FRP), ferrocement and Textile Reinforced Concrete (TRC) have been evaluated towards their performance efficiency and eco-effectiveness for sustainable retrofitting applications. Investigations have been carried out for flexural strengthening of RC beams with FRP, ferrocement and TRC. It is observed that in the case of FRP, it is not possible to tailor the material according to design requirements and most of the time strengthened structure becomes over stiff. Eco-effectiveness of these retrofitting materials has been evaluated by computing the embodied energy. It is observed that the amount of CO2 emitted by TRC is less compared to other retrofit materials. Further, the performance point of retrofitted RC frames has been evaluated and damage index has been calculated to find out the effective retrofit material. It is concluded that, if RC frame is retrofitted with FRP and TRC, it undergoes less damage compared to ferrocement.

  11. Non-linear heterogeneous FE approach for FRP strengthened masonry arches

    NASA Astrophysics Data System (ADS)

    Bertolesi, Elisa; Milani, Gabriele; Fedele, Roberto

    2015-12-01

    A fast and reliable non-linear heterogeneous FE approach specifically conceived for the analysis of FRP-reinforced masonry arches is presented. The approach proposed relies into the reduction of mortar joints to interfaces exhibiting a non-linear holonomic behavior, with a discretization of bricks by means of four-noded elastic elements. The FRP reinforcement is modeled by means of truss elements with elastic-brittle behavior, where the peak tensile strength is estimated by means of a consolidated approach provided by the Italian guidelines CNR-DT200 on masonry strengthening with fiber materials, where the delamination of the strip from the support is taken into account. The model is validated against some recent experimental results relying into circular masonry arches reinforced at both the intrados and the extrados. Some sensitivity analyses are conducted varying the peak tensile strength of the trusses representing the FRP reinforcement.

  12. Perspectives Of Employment Of Pultruded FRP Structural Elements In Seismic Engineering Field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russo, Salvatore; Silvestri, Mirko

    2008-07-08

    Today the employment of FRP material in structural engineering is in common use, with excellent results in term of applications especially as reinforcement of existing structures. This success is related to the very reduced weight of FRP material, to its performance in term of strength and durability and thanks to the easy use in technical application. There is a modern way to use this material disguised as structural pultruded element (with weight equal to 1600-1800 kg/m{sup 3}) in new constructions, local reinforcements and in other seismic applications. Actually the international technical and scientific literature in form of draft, recommendations andmore » researches on this topic is very rich also taking into account Italian contribution. Some interesting applications of all FRP structures in seismic engineering field are showed in this research in real terms and in form of capability.« less

  13. Vacuum Surface Flashover Characteristics and Secondary Electron Emission Characteristics of Epoxy Resin and FRP Insulator

    NASA Astrophysics Data System (ADS)

    Yamano, Yasushi; Takahashi, Masahiro; Kobayashi, Shinichi; Hanada, Masaya; Ikeda, Yoshitaka

    Neutral beam injectors (NBI) used for JT-60 are required to generate negative ions of 500 keV energies. To produce such high-energy ions, the electrostatic accelerators consisting of 3-stage of electrodes and three insulator rings are applied. The insulators are made of Fiberglass Reinforced Plastic (FRP) which is composed of epoxy resin and glass fibers. The surface discharges along the insulators are one of the most serious problems in the development of NBI. To increase the hold-off voltage against surface flashover events, it is necessary to investigate the FRP and epoxy resin insulator properties related to surface discharges in vacuum. This paper describes surface flashover characteristics for epoxy resin, FRP and Alumina samples under vacuum condition. In addition, the measurements of secondary electron emission (SEE) characteristics are also reported. These are important parameters to analyze surface discharge characteristics of insulators in vacuum.

  14. Use of pultruded reinforced plastics in energy generation and energy related applications

    NASA Astrophysics Data System (ADS)

    Anderson, R.

    Applications of pultrusion-formed fiber-reinforced plastics (FRP) in the wind, oil, and coal derived energy industries are reviewed. FRP is noted to be a viable alternative to wood, aluminum, and steel for reasons of availability, price, and weight. Attention is given to the development of FRP wind turbine blades for the DOE 8 kW low cost, high reliability wind turbine program. The blades feature a NACA 23112 profile with a 15 in. chord on the system which was tested at Rocky Flats, CO. Fabricating the blades involved a plus and minus 45 deg roving orientation, a heavy fiber-glass nose piece to assure blade strength, and a separately manufactured foam core. Additional uses for FRP products have been found in the structural members of coal stack scrubbers using a vinyl ester resin in a fire retardant formulation, and as low cost, light weight sucker rods for deep well oil drilling.

  15. Sectional mandibular complete denture for a total maxillectomy patient with trismus: a clinical report.

    PubMed

    Celakil, Tamer; Demir, Azize; Keskin, Haluk

    2017-01-01

    This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  16. 21 CFR 872.3400 - Karaya and sodium borate with or without acacia denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... denture adhesive. 872.3400 Section 872.3400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... and sodium borate with or without acacia denture adhesive. (a) Identification. A karaya and sodium borate with or without acacia denture adhesive is a device composed of karaya and sodium borate with or...

  17. Effectiveness of Hexetidine 0.1% Compared to Chlorhexidine Digluconate 0.12% in Eliminating Candida Albicans Colonizing Dentures: A Randomized Clinical In Vivo Study.

    PubMed

    Aoun, Georges; Saadeh, Maria; Berberi, Antoine

    2015-08-01

    Denture hygiene is an important factor in the prevention and treatment of denture stomatitis (DS). This study aimed to evaluate the efficacy of two different mouthwashes (chlorhexidine digluconate 0.12% and hexetidine 0.1%) in eliminating Candida albicans on dentures. A total of 60 denture wearers (20 men, 40 women; age range 40-80 years) with clinical evidence of DS were randomly divided into 2 test groups and 1 control group. The dentures of each test group were treated by immersion in one of the two mouthwashes while those of the control group were immersed in distilled water. Swab samples from the palatal surfaces of the upper dentures were collected before and after of cleaner use and examined mycologically. Reduction in the number of colony-forming units of Candida albicans after immersion of the dentures with chlorhexidine digluconate 0.12% was significantly greater than that of the group using hexetidine 0.1% and those of the control group. Hexetidine 0.1% solution tested for the first time as a product of disinfection of the acrylic dentures showed average results after immersion of 8 night hours for 4 days and was less effective than chlorhexidine digluconate 0.12%.

  18. [Longitudinal survey and analysis among Chengdu residents on cognition and acceptance of implant dentures].

    PubMed

    Zuo, Yanping; Wang, Yongyue; Wang, Luming; Du, Bing

    2014-08-01

    This study aims to survey the cognition and acceptance of implant dentures among Chengdu residents in 2005 and 2013 and to comparatively analyze the differences and influencing factors. A questionnaire was designed for this study. Its main content included basic demographics of respondents (gender, age, cultural level, and income level), cognition level of implant dentures (concept and main characteristics of implant dentures), main concern of respondents regarding implant dentures and medical institutions, and acceptance level of the price of implant dentures, among others. The sampling survey was carried out among Chengdu residents in 2005 and 2013 using the designed questionnaire. The results were then statistically analyzed. Up to 908 valid questionnaires in 2005 and 905 valid questionnaires in 2013 were obtained. The level of cognition of implant dentures was higher in 2013 than in 2005, and the correlation between cognition and cultural level and that between cognition and income level were both positive. However, the correlation between cognition and age was negative. The success rate for implant dentures and medical treatment technology of medical institutions were the factors that the respondents were mainly concerned with. The main methods for disseminating information on implant dentures were the internet, television, newspapers, magazines, and introduction by friends. With the development of the society's economy and the improvement of culture and income level of Chengdu residents, the cognition and acceptance level of implant dentures have gradualy increased. Meanwhile, health education and medical technology still need to be strengthened.

  19. Correlation of masticatory muscle activity with masticatory ability in complete denture patients with canine guidance and balanced occlusion

    NASA Astrophysics Data System (ADS)

    Maxwell, D.; Odang, R. W.; Koesmaningati, H.

    2017-08-01

    Balanced occlusion is commonly used in complete denture occlusion scheme; however, canine guidance offers a simpler process and reduces alveolar ridge resorption. Correlative research of these two occlusion schemes is required. This study was done to analyze the correlation between masticatory muscle activity and masticatory ability of the subjects with canine guidance and balanced occlusion complete dentures. Ten denture wearers participated in this cross-over clinical trial, and five subjects were randomly selected to wear balanced occlusion followed by canine guidance complete dentures and vice versa. Electromyogram (EMG) activities of superficial masseter and anterior temporal muscles were measured and masticatory ability questionnaires were collected 30 days after the subjects wore each occlusal scheme. There were significant differences between the EMG activities of masticatory muscles in subjects who were given canine guidance and balanced occlusion complete dentures (p < 0.05). Subjects rated their masticatory ability as being significantly better when using canine guidance dentures (p = 0.046). There was a significant and strong correlation (p = 0.045; r = 0.642) between the EMG activity of anterior temporal muscles and masticatory ability when the subjects wore balanced occlusion dentures and between the EMG activity of superficial masseter muscles and masticatory ability (p = 0.043; r = 0.648) when wearing canine guidance dentures. Masticatory ability is better when using canine guidance dentures. There is a significant and strong correlation between masticatory muscle activity and masticatory ability.

  20. Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.

    PubMed

    Polyzois, Gregory; Lagouvardos, Panagiotis; Frangou, Maria; Stefaniotis, Theodoros

    2011-07-01

    The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega(®), Corega Ultra(®), Super Corega Powder(®) and Fittydent Cationic(®) were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland-Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p < 0.05), denture types (p < 0.05) and biting sites (p < 0.05) with both devices. Bland-Altman plot and Mountain plots indicated a poor agreement of the two devices. It was concluded that denture adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.

  1. Improving mechanical properties of maxillary complete dentures through a bioinspired engineering design.

    PubMed

    White, James A P; Bond, Ian P; Jagger, Daryll C

    2011-01-01

    This study investigated how ribbed design features, including palatal rugae, may be used to significantly improve the structural performance of a maxillary denture under load. A computer-aided design model of a generic maxillary denture, incorporating various rib features, was created and imported into a finite element analysis program. The denture and ribbed features were assigned the material properties of standard denture acrylic resin, and load was applied in two different ways: the first simulating a three-point flexural bend of the posterior section and the second simulating loading of the entire palatal region. To investigate the combined use of ribbing and reinforcement, the same simulations were repeated with the ribbed features having a Young modulus two orders of magnitude greater than denture acrylic resin. For a prescribed load, total displacements of tracking nodes were compared to those of a control denture (without ribbing) to assess relative denture rigidity. When subjected to flexural loading, an increase in rib depth was seen to result in a reduction of both the transverse displacement of the last molar and vertical displacement at the centerline. However, ribbed features assigned the material properties of denture acrylic resin require a depth that may impose on speech and bolus propulsion before significant improvements are observed. The use of ribbed features, when made from a significantly stiffer material (eg, fiber-reinforced polymer) and designed to mimic palatal rugae, offer an acceptable method of providing significant improvements in rigidity to a maxillary denture under flexural load.

  2. Detection of Fatigue Crack in Basalt FRP Laminate Composite Pipe using Electrical Potential Change Method

    NASA Astrophysics Data System (ADS)

    Altabey, Wael A.; Noori, Mohammed

    2017-05-01

    Novel modulation electrical potential change (EPC) method for fatigue crack detection in a basalt fibre reinforced polymer (FRP) laminate composite pipe is carried out in this paper. The technique is applied to a laminate pipe with an embedded crack in three layers [0º/90º/0º]s. EPC is applied for evaluating the dielectric properties of basalt FRP pipe by using an electrical capacitance sensor (ECS) to discern damages in the pipe. Twelve electrodes are mounted on the outer surface of the pipe and the changes in the modulation dielectric properties of the piping system are analyzed to detect damages in the pipe. An embedded crack is created by a fatigue internal pressure test. The capacitance values, capacitance change and node potential distribution of ECS electrodes are calculated before and after crack initiates using a finite element method (FEM) by ANSYS and MATLAB, which are combined to simulate sensor characteristics and fatigue behaviour. The crack lengths of the basalt FRP are investigated for various number of cycles to failure for determining crack growth rate. Response surfaces are adopted as a tool for solving inverse problems to estimate crack lengths from the measured electric potential differences of all segments between electrodes to validate the FEM results. The results show that, the good convergence between the FEM and estimated results. Also the results of this study show that the electrical potential difference of the basalt FRP laminate increases during cyclic loading, caused by matrix cracking. The results indicate that the proposed method successfully provides fatigue crack detection for basalt FRP laminate composite pipes.

  3. Space requirement of a prefabricated bar on two interforaminal implants: a prospective clinical study.

    PubMed

    Albrecht, Dominic; Ramierez, Ami; Kremer, Urs; Katsoulis, Joannis; Mericske-Stern, Regina; Enkling, Norbert

    2015-02-01

    This clinical study measured the dimensional changes of existing lower complete dentures due to the integration of a prefabricated implant bar. Additionally, the impact of this dimensional change on patient satisfaction and oral function was analyzed. Twenty edentulous patients (10 men/10 women; aged 65.9 ± 11.8 years) received two interforaminal implants. Subsequent to surgery, a chair side adapted, prefabricated bar (SFI Bar(®), C+M, Biel, Switzerland) was inserted, and the matrix was polymerized into the existing lower denture. The change of the denture's lingual dimension was recorded by means of a bicolored, silicone denture duplicate that was sectioned in the oro-vestibular direction in the regions of the symphysis (S) and the implants (I-left, I-right). On the sections, the dimensional increase was measured using a light microscope. Six months after bar insertion, patients answered a standardized questionnaire. All dentures exhibited increased lingual volume, more extensively at S than at I (P = 0.001). At S, the median diagonal size of the denture was doubled (+4.33 mm), and at I, the median increase was 50% (I-left/-right = +2.66/+2.62 mm). The original denture size influenced the volume increase (P = 0.024): smaller dentures led to a larger increase. The amount of denture increase did not have negative impact on either self-perceived oral function or patient satisfaction. Approximately, 95% of the patients were satisfied with the treatment results. The lingual size of a lower denture was enlarged by the integration of a prefabricated bar without any negative side effects. Thus, this attachment system is suitable to convert an existing full denture into an implant-supported overdenture. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. A Clinical Study to Examine the Effect of Complete Denture on Head Posture/Craniovertical Angle.

    PubMed

    Khare, Amit; Nandeeshwar, D B; Sangur, Rajashekar; Makkar, Sumit; Khare, Pooja; Chitumalla, Rajkiran; Prasad, Renuka

    2016-04-01

    Edentulous patients show some significant changes in ridge relationship caused by resorption of alveolar ridge. The changes are characterized by an upward rotation of mandible, increase in mandibular prognathism that ultimately results in change of natural head posture. This clinical study was planned to know the effect of complete denture on head posture in different age groups of Indian completely edentulous population, after placement of complete denture at various time intervals. The sample consisted of completely edentulous patients without previous experience of the dentures. They were divided into 2 age groups: Group A (45-60) and Group B (61-75). During placement of complete denture craniovertical angle was measured with the help of custom made ruler protector device. Readings were taken before denture placement, immediately after denture placement, 30 minutes, 24 hours and 30 days after dentures placement. The results of this study indicated that in most of the patients (90%) despite their age, change in head posture (extension) occurred immediately after the denture placement. Thereafter reading remains same for measurement at 30 minutes and 24 hours of denture placement. However after 30 days, observation revealed that all the patients showed reduced craniovertical angle (flexion). Even though the values of craniovertical angle remain higher than its baseline in both groups, significant changes were noticed only in Group A. Findings revealed that head posture was significantly altered by the placement of dentures in completely edentulous patients. Within the time interval of 30 minutes and 24 hours extension of head posture remained constant with slight variation. Although after 30 days, changes remained significant for group 'A', but no significant changes were observed in the subjects of group 'B'.

  5. Response of No-Name Creek FRP Bridge to Local Weather : Technical Summary

    DOT National Transportation Integrated Search

    2012-09-01

    Since 1996, over 30 Fiber Reinforced Polymer (FRP) composite bridges have been installed in the United States. Bridge locations are in Kansas, Missouri, New York, Iowa, Colorado, West Virginia, Ohio, California, Idaho, Washington, Pennsylvania, Illin...

  6. Long term monitoring of mechanical properties of FRP repair materials.

    DOT National Transportation Integrated Search

    2013-06-01

    Over the years, Fiber Reinforced Polymer (FRP) composites have gained popularity in transportation infrastructure as a material able to restore and increase the capacity of existing concrete elements. Properties such as a high strength to weight rati...

  7. Development and performance evaluation of fiber reinforced polymer bridge.

    DOT National Transportation Integrated Search

    2014-03-01

    Fiber reinforced polymers (FRP) have become more popular construction materials in the last decade due to the reduction of : material costs. The installation and performance evaluation of the first FRP-wrapped balsa wood bridge in Louisiana is descri...

  8. Research notes : non-destructive evaluation of FRP-strengthened reinforced concrete.

    DOT National Transportation Integrated Search

    2005-04-01

    Many reinforced concrete structures across the country are being strengthened with fiber reinforced polymer (FRP) composites to increase the load capacity. In many cases, composites provide the most cost effective strengthening option, and they do no...

  9. Response of No-Name Creek FRP Bridge to Local Weather : Technical Summary

    DOT National Transportation Integrated Search

    2012-09-01

    Since 1996, over 30 Fiber Reinforced Polymer (FRP) composite bridges have been installed : in the United States. Bridge locations are in Kansas, Missouri, New York, Iowa, Colorado, West : Virginia, Ohio, California, Idaho, Washington, Pennsylvania, I...

  10. Nondestructive evaluation of fiber reinforced polymer bridges and decks.

    DOT National Transportation Integrated Search

    2003-10-01

    The research described herein involved both nondestructive evaluation and destructive testing of an FRP honeycomb specimen. The specimen is representative of an FRP bridge that is to be constructed in Troupsburg, New York. The specimen was tested in ...

  11. Fiber reinforced polymer bridge decks : [technical summary].

    DOT National Transportation Integrated Search

    2011-01-01

    A number of researchers have addressed the use of Fiber Reinforced Polymer (FRP) deck as a replacement solution for deteriorated bridge decks made of traditional materials. The use of new, advanced materials such as FRP is advantageous when the bridg...

  12. A novel gene's role in an ancient mechanism: secreted Frizzled-related protein 1 is a critical component in the anterior-posterior Wnt signaling network that governs the establishment of the anterior neuroectoderm in sea urchin embryos.

    PubMed

    Khadka, Anita; Martínez-Bartolomé, Marina; Burr, Stephanie D; Range, Ryan C

    2018-01-01

    The anterior neuroectoderm (ANE) in many deuterostome embryos (echinoderms, hemichordates, urochordates, cephalochordates, and vertebrates) is progressively restricted along the anterior-posterior axis to a domain around the anterior pole. In the sea urchin embryo, three integrated Wnt signaling branches (Wnt/β-catenin, Wnt/JNK, and Wnt/PKC) govern this progressive restriction process, which begins around the 32- to 60-cell stage and terminates by the early gastrula stage. We previously have established that several secreted Wnt modulators of the Dickkopf and secreted Frizzled-related protein families (Dkk1, Dkk3, and sFRP-1/5) are expressed within the ANE and play important roles in modulating the Wnt signaling network during this process. In this study, we use morpholino and dominant-negative interference approaches to characterize the function of a novel Frizzled-related protein, secreted Frizzled-related protein 1 (sFRP-1), during ANE restriction. sFRP-1 appears to be related to a secreted Wnt modulator, sFRP3/4, that is essential to block Wnt signaling and establish the ANE in vertebrates. Here, we show that the sea urchin sFRP3/4 orthologue is not expressed during ANE restriction in the sea urchin embryo. Instead, our results indicate that ubiquitously expressed maternal sFRP-1 and Fzl1/2/7 signaling act together as early as the 32- to 60-cell stage to antagonize the ANE restriction mechanism mediated by Wnt/β-catenin and Wnt/JNK signaling. Then, starting from the blastula stage, Fzl5/8 signaling activates zygotic sFRP-1 within the ANE territory, where it works with the secreted Wnt antagonist Dkk1 (also activated by Fzl5/8 signaling) to antagonize Wnt1/Wnt8-Fzl5/8-JNK signaling in a negative feedback mechanism that defines the outer ANE territory boundary. Together, these data indicate that maternal and zygotic sFRP-1 protects the ANE territory by antagonizing the Wnt1/Wnt8-Fzl5/8-JNK signaling pathway throughout ANE restriction, providing precise spatiotemporal control of the mechanism responsible for the establishment of the ANE territory around the anterior pole of the sea urchin embryo.

  13. Effect of repair resin type and surface treatment on the repair strength of heat-polymerized denture base resin.

    PubMed

    Alkurt, Murat; Yeşil Duymuş, Zeynep; Gundogdu, Mustafa

    2014-01-01

    Acrylic resin denture fracture is common in prosthodontic practice. When fractured denture bases are repaired, recurrent fractures frequently occur at the repair surface interface or adjacent areas. The purpose of this study was to evaluate the effect of different surface treatments on the flexural strength of the acrylic resin denture base repaired with heat-polymerized acrylic resin, autopolymerizing resin, and light-polymerized acrylic resin. Ninety-six specimens of heat-polymerized acrylic resin were prepared according to the American Dental Association Specification No. 12 (65.0 × 10.0 × 2.5 mm) and sectioned into halves to create a repair gap (3.0 × 10 × 2.5 mm). The sectioned specimens were divided into 3 groups according to their repair materials. The specimens from each group were divided into 4 subgroups according to their surface treatments: a control group without any surface treatment; an experimental group treated with methyl methacrylate monomer (MMA group); an experimental group treated with airborne-particle abrasion with aluminum oxide particles of 250-μm particle size (abrasion group); and an experimental group treated with erbium:yttrium-aluminum-garnet laser (laser group). After the surface treatments, the 3 materials were placed into the repair gaps and then polymerized. After all of the specimens had been ground and polished, they were stored in distilled water at 37°C for 1 week and subjected to a 3-point bend test. Data were analyzed with a 2-way analysis of variance, and the Tukey honestly significant difference test was performed to identify significant differences (α=.05). The effects of the surface treatments and repair resins on the surface of the denture base resin were examined with scanning electron microscopy. Significant differences were found among the groups in terms of repair resin type (P<.001). All surface-treated specimens had higher flexural strength than controls, except the surface treated with the methyl methacrylate in the heat-polymerized group. A significant difference between the control and abrasion groups (P=.013) was found. The scanning electron microscopy observations showed that the application of surface treatments modified the surface of the denture base resin. The repair procedure with heat-polymerized resin exhibited significantly higher flexural strength than that of the autopolymerized and light-polymerized resins. In addition, the airborne-particle abrasion with aluminum oxide particles of 250-μm particle size improved the flexural strength of the specimens tested. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  14. Simultaneous life extension and crack monitoring of fatigue-damaged steel members using multifunctional carbon nanotube based composites

    NASA Astrophysics Data System (ADS)

    Ahmed, Shafique; Schumacher, Thomas; Thostenson, Erik T.; McConnell, Jennifer

    2017-04-01

    Steel structures including bridges are susceptible to cracking, particularly due to fatigue-sensitive details found in older designs. Therefore, one of the major challenges to keep those steel bridges in service is to rehabilitate existing and potential fatigue damage. There are several conventional approaches to extend the fatigue-life of damaged steel members, e.g., drilling a crack stop-hole to reduce the stress concentration at the crack tip as well as welding and bolting of steel plates or adhesive-bonding of fiber-reinforced polymers (FRP) to reduce the overall stresses. Improvement in material properties of FRP and adhesives make them a viable candidate to apply for extending the fatigue-life of steel members. However, drawbacks include the potential for debonding of the adhesive layer and/or interfaces between adhesive and adherents as well as difficulty in monitoring fatigue crack growth after rehabilitation. In this research, a holistic approach is proposed and evaluated for simultaneous extension of fatigue-life and monitoring by integrating a carbon nanotube (CNT)-based sensing layer with an adhesively-bonded FRP reinforcement. CNT-based sensing layers have a nerve-like electric resistance network, which enables distributed sensing capabilities to monitor stress levels, crack growth, and damage progression. Using laboratory-scale experiments, the simultaneous fatigue-life extension and crack monitoring capability of multifunctional CNT-based composites was evaluated. This paper introduces the fundamental concept of integrated fatigue-rehabilitation and monitoring of steel members, presents a laboratory-scale experiment to demonstrate the feasibility and effectiveness, and discusses challenges for implementation in real structures.

  15. Provision of a swing lock denture for a patient with Gorlin Goltz syndrome.

    PubMed

    Razaq, I; Durey, K; Nattress, B

    2012-09-01

    Swinglock dentures are used relatively infrequently but in cases of compromised anatomy or where the pattern of tooth loss is unfavourable, they provide a useful removable partial denture design option. The aim of this article is to provide a clear summary of the clinical and technical considerations necessary when providing a Swinglock denture.

  16. A System Approach to Navy Medical Education and Training. Appendix 44. Competency Curriculum for Dental Assistant.

    DTIC Science & Technology

    1974-08-31

    Prosthodontic Appliances - Partial Dentures .... ....... ....... .... 59 2. Removable Prosthodontic Appliances - Full Dentures ..... ........... . 60 3...PROCEDURES I This unit includes the following Modules: Number Title Page 1 Removable Prosthodontic Appliances - Partial Dentures 59. ......... ...... 2...Removable Prostbodontic Appliances - Full Dentures ..... ...... a .. .. .. . 60 3 Fixed Prosthodontic Appliances - Fixed Bridge. . 61 4 Mouthquard

  17. Expectations and satisfaction of denture patients in a university clinic.

    PubMed

    Davis, E L; Albino, J E; Tedesco, L A; Portenoy, B S; Ortman, L F

    1986-01-01

    These results indicate that patients' expectations of dentures before treatment were unrealistically high and that informational videotapes did not significantly affect these expectations. Satisfaction with current dentures was surprisingly high before treatment and increased significantly from pretreatment to postreatment for both groups in the study. While it is likely that this increase in satisfaction reflects a change from poor to excellent denture status, this finding may also be attributed to cognitive dissonance theory; that is, high satisfaction may represent the means by which patients justify the expenses of their denture treatment. Although the videotape presentations did not alter the expectations of patients and their satisfaction with dentures, the tapes represent a potential source of accurate, standardized information for both patient and student dentist.

  18. Surface Passivation of ZrO2 Artificial Dentures by Magnetized Coaxial Plasma deposition

    NASA Astrophysics Data System (ADS)

    Arai, Soya; Kurumi, Satoshi; Matsuda, Ken-Ichi; Suzuki, Kaoru; Hara, Katsuya; Kato, Tatsuya; Asai, Tomohiko; Hirose, Hideharu; Masutani, Shigeyuki; Nihon University Team

    2015-09-01

    Recent growth and fabrication technologies for functional materials have been greatly contributed to drastic development of oral surgery field. Zirconia based ceramics is expected to utilize artificial dentures because these ceramics have good biocompatibility, high hardness and aesthetic attractively. However, to apply these ceramics to artificial dentures, this denture is removed from a dental plate because of weakly bond. For improving this problem, synthesis an Al passivation-layer on the ceramics for bonding with these dental items is suitable. In order to deposit the passivation layer, we focused on a magnetized coaxial plasma deposition (MCPD). The greatest characteristic of MCPD is that high-melting point metal can be deposited on various substrates. Additionally, adhesion force between substrate and films deposited by the MCPD is superior to it of general deposition methods. In this study, we have reported on the growth techniques of Al films on ZrO2 for contributing to oral surgery by the MCPD. Surface of deposited films shows there were some droplets and thickness of it is about 200 nm. Thickness is increased to 500 nm with increasing applied voltage.

  19. A comparison of mandibular denture base deformation with different impression techniques for implant overdentures.

    PubMed

    Elsyad, Moustafa Abdou; El-Waseef, Fatma Ahmad; Al-Mahdy, Yasmeen Fathy; Fouad, Mohammed Mohammed

    2013-08-01

    This study aimed to evaluate mandibular denture base deformation along with three impression techniques used for implant-retained overdenture. Ten edentulous patients (five men and five women) received two implants in the canine region of the mandible and three duplicate mandibular overdentures which were constructed with mucostatic, selective pressure, and definitive pressure impression techniques. Ball abutments and respective gold matrices were used to connect the overdentures to the implants. Six linear strain gauges were bonded to the lingual polished surface of each duplicate overdenture at midline and implant areas to measure strain during maximal clenching and gum chewing. The strains recorded at midline were compressive while strains at implant areas were tensile. Clenching recorded significant higher strain when compared with gum chewing for all techniques. The mucostatic technique recorded the highest strain and the definite pressure technique recorded the lowest. There was no significant difference between the strain recorded with mucostatic technique and that registered with selective pressure technique. The highest strain was recorded at the level of ball abutment's top with the mucostatic technique during clenching. Definite pressure impression technique for implant-retained mandibular overdenture is associated with minimal denture deformation during function when compared with mucostatic and selective pressure techniques. Reinforcement of the denture base over the implants may be recommended to increase resistance of fracture when mucostatic or selective pressure impression technique is used. © 2012 John Wiley & Sons A/S.

  20. Design of FRP systems for strengthening concrete girders in shear.

    DOT National Transportation Integrated Search

    2011-06-01

    FRP systems have been used on a project-specific basis for the last two decades. They are now becoming a widely accepted method of : strengthening concrete structures. The acceptance and utilization of these new strengthening techniques depend on the...

  1. Highly accelerated lifetime for externally applied bond critical fiber-reinforced polymer (FRP) infrastructure materials.

    DOT National Transportation Integrated Search

    2014-03-01

    This report describes a research project to investigate accelerated aging protocols for fiber-reinforced : polymer (FRP) reinforcement of concrete. This research was conducted in three stages. In the first : stage, various spectroscopic techniques we...

  2. Polyurethane foam infill for fiber-reinforced polymer (FRP) bridge deck panels.

    DOT National Transportation Integrated Search

    2014-05-01

    The objective of the proposed research is to develop, test, and evaluate fiber-reinforced, polyurethane foams to replace the costly : honeycomb construction currently used to manufacture FRP bridge deck panels. The effort will focus on developing an ...

  3. Behavior of concrete specimens reinforced with composite materials : laboratory study

    DOT National Transportation Integrated Search

    2000-02-01

    The main objective of this study was to investigate the interaction between FRP composite and concrete by addressing the most important : variables in terms of FRP (fiber reinforced polymer) properties. Type of fibers, thickness of the laminates, fib...

  4. Finite element modeling of concrete structures strengthened with FRP laminates

    DOT National Transportation Integrated Search

    2001-05-01

    Linear and non-linear method models were developed for a reinforced concrete bridge that had been strengthened with fiber reinforced polymer (FRP) composites. ANSYS and SAP2000 modeling software were used; however, most of the development effort used...

  5. Long-term monitoring of mechanical properties of FRP repair materials.

    DOT National Transportation Integrated Search

    2013-07-01

    Fiber- reinforced polymer composites (FRP) are an attractive repair option for existing concrete structures. : CDOT has used this material on some projects, in particular the repair of the Castlewood Canyon Bridge in : 2003. Further use of the materi...

  6. Behavior of Concrete Cylinders Strengthened with a Basalt-FRP and Subjected to Mechanical Loads and Elevated Temperatures

    NASA Astrophysics Data System (ADS)

    Tulendinov, T.; Zesers, A.; Tamužs, V.

    2017-09-01

    Concrete samples were manufactured and strengthened with a basalt FRP (BFRP) using two kinds of winding patterns (spiral and tight). The efficiency of common and temperature-resistant epoxy binders were studied. Some of the samples were encased in an external concrete shell for an additional protection of the FRP reinforcement during heating. Both plain and polypropylene-microfiber-reinforced concretes were used for the external casing. Stress-strain relations of the samples before and after heating were obtained. The effects of high temperatures on the integrity of concrete samples with a BFRP reinforcement was investigated.

  7. Analytical, Numerical and Experimental Examination of Reinforced Composites Beams Covered with Carbon Fiber Reinforced Plastic

    NASA Astrophysics Data System (ADS)

    Kasimzade, A. A.; Tuhta, S.

    2012-03-01

    In the article, analytical, numerical (Finite Element Method) and experimental investigation results of beam that was strengthened with fiber reinforced plastic-FRP composite has been given as comparative, the effect of FRP wrapping number to the maximum load and moment capacity has been evaluated depending on this results. Carbon FRP qualitative dependences have been occurred between wrapping number and beam load and moment capacity for repair-strengthen the reinforced concrete beams with carbon fiber. Shown possibilities of application traditional known analysis programs, for the analysis of Carbon Fiber Reinforced Plastic (CFRP) strengthened structures.

  8. Comparison of Candida Albicans Adherence to Conventional Acrylic Denture Base Materials and Injection Molding Acrylic Materials

    PubMed Central

    Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh

    2017-01-01

    Statement of the Problem: Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. Purpose: The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Materials and Method: Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer’s instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×108 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Results: Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×103) comparing to injection molding acrylic resins (6×103) were statistically significant (p<0.001). Conclusion: Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis. PMID:28280761

  9. Comparison of Candida Albicans Adherence to Conventional Acrylic Denture Base Materials and Injection Molding Acrylic Materials.

    PubMed

    Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh

    2017-03-01

    Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer's instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×10 8 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×10 3 ) comparing to injection molding acrylic resins (6×10 3 ) were statistically significant ( p <0.001). Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis.

  10. In vitro treatment of Candida albicans biofilms on denture base material with volume dielectric barrier discharge plasma (VDBD) compared with common chemical antiseptics.

    PubMed

    Matthes, Rutger; Jablonowski, Lukasz; Koban, Ina; Quade, Antje; Hübner, Nils-Olaf; Schlueter, Rabea; Weltmann, Klaus-Dieter; von Woedtke, Thomas; Kramer, Axel; Kocher, Thomas

    2015-12-01

    To prevent oral candidiasis, it is crucial to inactivate Candida-based biofilms on dentures. Common denture cleansing solutions cannot sufficiently inactivate Candida albicans. Therefore, we investigated the anticandidal efficacy of a physical plasma against C. albicans biofilms in vitro. Argon or argon plasma with 1 % oxygen admixture was applied on C. albicans biofilms grown for 2, 7, or 16 days on polymethylmethacrylate discs; 0.1 % chlorhexidine digluconate (CHX) and 0.6 % sodium hypochlorite (NaOCl) solutions served as positive treatment controls. In addition, these two solutions were applied in combination with plasma for 30 min to assess potential synergistic effects. The anticandidal efficacy was determined by the number of colony forming units (CFU) in log(10) and expressed as reduction factor (RF, the difference between control and treated specimen). On 2-day-biofilms, plasma treatment alone or combined with 30 min CHX treatment led to significant differences of means of CFU (RF = 4.2 and RF = 4.3), clearly superior to CHX treatment alone (RF = 0.6). Plasma treatment of 7-day-or 16-day-old biofilms revealed no significant CFU reduction. The treatment of 7-day-old (RF = 1.7) and 16-day-old (RF = 1.3) biofilms was slightly more effective with NaOCl alone than with the combined treatment of NaOCl and plasma (RF = 1.6/RF = 1.9). The combination of CHX and plasma increased the RF immaterially. The use of plasma alone and in combination with antiseptics is promising anticandidal regimens for daily use on dentures when biofilms are not older than 2 days. Plasma could help to reduce denture-associated candidiasis.

  11. Crack detection and fatigue related delamination in FRP composites applied to concrete

    NASA Astrophysics Data System (ADS)

    Brown, Jeff; Baker, Rebecca; Kallemeyn, Lisa; Zendler, Andrew

    2008-03-01

    Reinforced concrete beams are designed to allow minor concrete cracking in the tension zone. The severity of cracking in a beam element is a good indicator of how well a structure is performing and whether or not repairs are needed to prevent structural failure. FRP composites are commonly used to increase the flexural and shear capacity of RC beam elements, but one potential disadvantage of this method is that strengthened surfaces are no longer visible and cracks or delaminations that result from excessive loading or fatigue may go undetected. This research investigated thermal imaging techniques for detecting load induced cracking in the concrete substrate and delamination of FRP strengthening systems applied to reinforced concrete (RC). One small-scale RC beam (5 in. x 6 in. x 60 in.) was strengthened with FRP and loaded to failure monotonically. An infrared thermography inspection was performed after failure. A second strengthened beam was loaded cyclically for 1,750,000 cycles to investigate how fatigue might affect substrate cracking and delamination growth throughout the service-life of a repaired element. No changes were observed in the FRP bond during/after the cyclic loading. The thermal imaging component of this research included pixel normalization to enhance detectability and characterization of this specific type of damage.

  12. Mechanical properties and aesthetics of FRP orthodontic wire fabricated by hot drawing.

    PubMed

    Imai, T; Watari, F; Yamagata, S; Kobayashi, M; Nagayama, K; Toyoizumi, Y; Nakamura, S

    1998-12-01

    The FRP wires 0.5 mm in diameter with a multiple fiber structure were fabricated by drawing the fiber polymer complex at 250 degrees C for an esthetic, transparent orthodontic wire. Biocompatible CaO-P2O5-SiO2-Al2O3 (CPSA) glass fibers of 8-20 microm in diameter were oriented unidirectionally in the longitudinal direction in PMMA matrix. The mechanical properties were investigated by 3-point flexural test. The FRP wire showed sufficient strength and a very good elastic recovery after deformation. Young's modulus and the flexural load at deflection 1 mm were nearly independent of the fiber diameter and linearly increased with the fiber fraction. The dependence on fiber fraction obeys well the rule of mixture. This FRP wire could cover the range of strength corresponding to the conventional metal orthodontic wires from Ni-Ti used in the initial stage of orthodontic treatments to Co-Cr used in the final stage by changing the volume ratio of glass fibers with the same external diameter. The estheticity in external appearance was excellent. Thus the new FRP wire can satisfy both mechanical properties necessary for an orthodontic wire and enough estheticity, which was not possible for the conventional metal wire.

  13. In-process, non-destructive multimodal dynamic testing of high-speed composite rotors

    NASA Astrophysics Data System (ADS)

    Kuschmierz, Robert; Filippatos, Angelos; Langkamp, Albert; Hufenbach, Werner; Czarske, Jürgern W.; Fischer, Andreas

    2014-03-01

    Fibre reinforced plastic (FRP) rotors are lightweight and offer great perspectives in high-speed applications such as turbo machinery. Currently, novel rotor structures and materials are investigated for the purpose of increasing machine efficiency, lifetime and loading limits. Due to complex rotor structures, high anisotropy and non-linear behavior of FRP under dynamic loads, an in-process measurement system is necessary to monitor and to investigate the evolution of damages under real operation conditions. A non-invasive, optical laser Doppler distance sensor measurement system is applied to determine the biaxial deformation of a bladed FRP rotor with micron uncertainty as well as the tangential blade vibrations at surface speeds above 300 m/s. The laser Doppler distance sensor is applicable under vacuum conditions. Measurements at varying loading conditions are used to determine elastic and plastic deformations. Furthermore they allow to determine hysteresis, fatigue, Eigenfrequency shifts and loading limits. The deformation measurements show a highly anisotropic and nonlinear behavior and offer a deeper understanding of the damage evolution in FRP rotors. The experimental results are used to validate and to calibrate a simulation model of the deformation. The simulation combines finite element analysis and a damage mechanics model. The combination of simulation and measurement system enables the monitoring and prediction of damage evolutions of FRP rotors in process.

  14. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P < .05). The labial strain on the palateless dentures with reinforcement was almost as low as the labial strain on dentures with palatal coverage in most implant configurations. Reinforcement of a palateless implant overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  15. Satisfaction in complete denture wearers with and without adhesives: A randomized, crossover, double-blind clinical trial

    PubMed Central

    Torres-Sánchez, Carlos; Montoya-Salazar, Vanessa; Gutierrez-Pérez, Jose-Luis; Jimenez-Castellanos, Emilio

    2018-01-01

    Background The purpose of this study was to compare the satisfaction of patients regarding retention, stability and accumulation of particles with a randomized, double-blind crossed method in users with complete dentures with and without adhesive. Material and Methods Seventeen edentulous individuals were randomized and received new upper and lower complete dentures. After a period of adaptation, they participated in some masticatory tests and clinical revisions, after use the protheses with and without the use of two denture adhesives: Adhesive A (Fittydent, Fittydent International GmbH) and adhesive B (Corega, GlaxoSmithKline) at 0, 7 and 14 days. Satisfaction was measured immediately after each test through a survey using a VAS scale (0-10) and data were analyzed with McNemar’s test with Bonferroni correction. Results The results showed significant differences (p<.01) between the study groups with adhesive A - B and the group without adhesive, but no significant differences were found between the two stickers for any of the variables studied. Conclusions Complete denture adhesives significantly improved the satisfaction of patients because a better retention, stability and less accumulation of particles of the food substitute between the denture and the mucosa is obtained compared with non-use of complete denture adhesives. Key words:Complete dentures, patient satisfaction, denture adhesives, clinical trials. PMID:29946414

  16. Mechanical and Physicochemical Properties of Newly Formed ZnO-PMMA Nanocomposites for Denture Bases.

    PubMed

    Cierech, Mariusz; Osica, Izabela; Kolenda, Adam; Wojnarowicz, Jacek; Szmigiel, Dariusz; Łojkowski, Witold; Kurzydłowski, Krzysztof; Ariga, Katsuhiko; Mierzwińska-Nastalska, Elżbieta

    2018-05-06

    The aim of this study was to investigate the selected properties of zinc oxide- polymethyl methacrylate (ZnO-PMMA) nanocomposites that can influence the microorganism deposition on their surface. Non-commercial ZnO-NPs were prepared, characterized and used for the preparation of PMMA nanocomposite. Roughness, absorbability, contact angle and hardness of this new nanomaterial were evaluated. PMMA without ZnO-NPs served as control. Compared to unenriched PMMA, incorporation of ZnO-NPs to 7.5% for PMMA nanocomposite increases the hardness (by 5.92%) and the hydrophilicity. After modification of the material with zinc oxide nanoparticles the roughness parameter did not change. All tested materials showed absorption within the range of 1.82 to 2.03%, which meets the requirements of International Organization for Standardization (ISO) standards for denture base polymers. The results showed no significant deterioration in the properties of acrylic resin that could disqualify the nanocomposite for clinical use. Increased hydrophilicity and hardness with absorbability within the normal range can explain the reduced microorganism growth on the denture base, as has been proven in a previous study.

  17. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    PubMed Central

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  18. Monitoring Poisson's Ratio Degradation of FRP Composites under Fatigue Loading Using Biaxially Embedded FBG Sensors.

    PubMed

    Akay, Erdem; Yilmaz, Cagatay; Kocaman, Esat S; Turkmen, Halit S; Yildiz, Mehmet

    2016-09-19

    The significance of strain measurement is obvious for the analysis of Fiber-Reinforced Polymer (FRP) composites. Conventional strain measurement methods are sufficient for static testing in general. Nevertheless, if the requirements exceed the capabilities of these conventional methods, more sophisticated techniques are necessary to obtain strain data. Fiber Bragg Grating (FBG) sensors have many advantages for strain measurement over conventional ones. Thus, the present paper suggests a novel method for biaxial strain measurement using embedded FBG sensors during the fatigue testing of FRP composites. Poisson's ratio and its reduction were monitored for each cyclic loading by using embedded FBG sensors for a given specimen and correlated with the fatigue stages determined based on the variations of the applied fatigue loading and temperature due to the autogenous heating to predict an oncoming failure of the continuous fiber-reinforced epoxy matrix composite specimens under fatigue loading. The results show that FBG sensor technology has a remarkable potential for monitoring the evolution of Poisson's ratio on a cycle-by-cycle basis, which can reliably be used towards tracking the fatigue stages of composite for structural health monitoring purposes.

  19. Monitoring Poisson’s Ratio Degradation of FRP Composites under Fatigue Loading Using Biaxially Embedded FBG Sensors

    PubMed Central

    Akay, Erdem; Yilmaz, Cagatay; Kocaman, Esat S.; Turkmen, Halit S.; Yildiz, Mehmet

    2016-01-01

    The significance of strain measurement is obvious for the analysis of Fiber-Reinforced Polymer (FRP) composites. Conventional strain measurement methods are sufficient for static testing in general. Nevertheless, if the requirements exceed the capabilities of these conventional methods, more sophisticated techniques are necessary to obtain strain data. Fiber Bragg Grating (FBG) sensors have many advantages for strain measurement over conventional ones. Thus, the present paper suggests a novel method for biaxial strain measurement using embedded FBG sensors during the fatigue testing of FRP composites. Poisson’s ratio and its reduction were monitored for each cyclic loading by using embedded FBG sensors for a given specimen and correlated with the fatigue stages determined based on the variations of the applied fatigue loading and temperature due to the autogenous heating to predict an oncoming failure of the continuous fiber-reinforced epoxy matrix composite specimens under fatigue loading. The results show that FBG sensor technology has a remarkable potential for monitoring the evolution of Poisson’s ratio on a cycle-by-cycle basis, which can reliably be used towards tracking the fatigue stages of composite for structural health monitoring purposes. PMID:28773901

  20. Lenticular card: a new method for denture identification.

    PubMed

    Colvenkar, Shreya S

    2010-01-01

    The need for denture marking is important for forensic and social reasons in case patients need to be identified individually. Majority of the surface marking and inclusion techniques are expensive, time consuming, and do not permit the incorporation of large amounts of information. In this article, the method to include a lenticular identification card stood out from the currently available denture marking methods in various ways. The lenticular card stores the patient's information has two or more images that can be viewed by changing the angle of view. The maxillary denture was processed according to the manufacturer's instructions. The lenticular identification card was incorporated in the external posterior buccal surface of the maxillary denture using salt and pepper technique. For testing of durability, denture with the identifier was placed in water for up to 4 months. The proposed method is simple, cheap, and can store a large amount of information, thus allowing quick identification of the denture wearer. The labels showed no sign of fading or deterioration.

  1. Influence of reinforcement on strains within maxillary implant overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    2015-01-01

    The purpose of this study was to examine the influence of reinforcement of an embedded cast on the strains within maxillary implant overdentures. A maxillary edentulous model with implants placed bilaterally in the canine positions, dome-shaped copings, and experimental overdentures was fabricated. Rosette-type strain gauges were attached in the canine positions and at three points along the midline of the polished surface of the denture and connected to the sensor interface controlled by a personal computer. Experimental dentures with five different reinforcements were tested: without reinforcement; with a cast cobalt-chrome reinforcement over the residual ridge and the tops of the copings; with the same reinforcement from first molar to first molar, over the residual ridge and the tops of the copings; with the same reinforcement over the residual ridge and the sides of the copings; and with the same reinforcement from first molar to first molar, over the residual ridge and the sides of the copings. A vertical occlusal load of 49 N was applied to the first premolar and then to the first molar, and the strains were measured and compared by analysis of variance. In both loading situations, significantly less strain was recorded in dentures with reinforcement than in those without reinforcement. When the first premolar was loaded on dentures with and without palatal reinforcement at the first premolars, the strains on the denture with reinforcement over the tops of the copings were significantly lower than on the denture with reinforcement over the sides of the copings at the canine position. Cast reinforcement over the residual ridge and the top of copings embedded in an acrylic base reduced the strain from occlusal stress on maxillary implant overdentures.

  2. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    PubMed

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  3. Denture Care: How Do I Clean Dentures?

    MedlinePlus

    ... Avoid stiff-bristled brushes, strong cleansers and harsh toothpaste, as these are too abrasive and can damage your dentures. Whitening toothpastes. Toothpastes advertised as whitening pastes often contain peroxide, ...

  4. The physical mechanisms of complete denture retention.

    PubMed

    Darvell, B W; Clark, R K

    2000-09-09

    The purpose of this article is to assist the practitioner to understand which factors are relevant to complete denture retention in the light of the current understanding of physics and materials science and thus to guide design. Atmospheric pressure, vacuum, adhesion, cohesion, surface tension, viscosity, base adaption, border seal, seating force and muscular control have all been cited at one time or another as major or contributory factors, but usually as an opinion without proper reference to fundamental principles. Although there has been a detailed analysis published, it seems appropriate that a restatement of the points in a collated form be made. In fact, denture retention is a dynamic issue dependent on the control of the flow of interposed fluid and thus its viscosity and film thickness, while the timescale of displacement loading affects the assessment. Surface tension forces at the periphery contribute to retention, but the most important concerns are good base adaptation and border seal. These must be achieved if full advantage is to be taken of the saliva flow-related effects.

  5. Repair of impact damaged utility poles with fiber reinforced polymers (FRP), phase II.

    DOT National Transportation Integrated Search

    2015-06-01

    Vehicle collisions with steel or aluminum utility poles are common occurrences that yield substantial but often repairable : damage. This project investigates the use of a fiber-reinforced polymer (FRP) composite system for in situ repair that : mini...

  6. Hybrid FRP-concrete bridge deck system final report I : development and system performance validation.

    DOT National Transportation Integrated Search

    2009-10-01

    In this study, the concept of the hybrid FRP-concrete structural systems was applied to both bridge : superstructure and deck systems. Results from the both experimental and computational analysis for : both the hybrid bridge superstructure and deck ...

  7. Behavior of hollow-core FRP-concrete-steel columns subjected to cyclic axial compression.

    DOT National Transportation Integrated Search

    2014-08-01

    This report presents the results of an experimental study that was conducted to investigate the effects of key parameters on the compressive behavior of fiber reinforced polymer (FRP)-concrete-steel double-skin tubular columns (FSDT). Hybrid FSDT col...

  8. "Nature cures:" An alternative herbal formulation as a denture cleanser.

    PubMed

    Sushma, R; Sathe, Tanuja Tanaji; Farias, Anand; Sanyal, Pronob Kumar; Kiran, Shashi

    2017-01-01

    Candida albicans is one of the microorganisms which harbor the oral cavity, especially in elderly. However, the incidence of existence of this increases in patients using removable dental prosthesis. There is therefore a need to test the anticandidal efficacy of these cost-effective, easily available products to be used as routine denture cleansers. (1) To evaluate antifungal properties of triphala churna on the heat cure denture base material. (2) To evaluate the antifungal effect of chlorhexidine gluconate on the heat cure denture base material. (3) To compare the antifungal effect of triphala churna and chlorhexidine gluconate with a control. (4) To evaluate which among triphala churna and chlorhexidine gluconate has a better antifungal property on the heat cure denture base material. Study population consisted of sixty dentures wearers from those attending the Outpatient Department of Prosthodontics of the School of Dentistry, Krishna Institute of Medical Sciences Deemed University, Karad. Swabs were collected from the dentures before and after the use of triphala and chlorhexidine. The swabs were cultured on Sabouraud dextrose agar and the total Candida counts were determined. Triphala as an antifungal is shown to have more efficacy than the conventional chlorhexidine mouthwash. Résumé Arrière-plan: Candida albicans est l'un des micro-organismes qui abritent la cavité buccale surtout chez les personnes âgées. Cependant, l'incidence de l'existence de cette augmentation chez les patients utilisant des prothèses dentaires amovibles. Il est donc nécessaire de tester l'efficacité anticancédique de ces produits rentables et faciles à utiliser pour être utilisés comme nettoyants de routine pour prothèses dentaires. Buts et Objectifs: (1) Évaluer les propriétés antifongiques de Triphala churna sur le matériau de base de la prothèse thermo-durcissable. (2) Évaluer l'effet antifongique du gluconate de chlorhexidine sur le matériau de base de la prothèse thermo-durcissable. (3) Comparer l'effet antifongique de Triphala churna et du gluconate de chlorhexidine avec un témoin. (4) Évaluer lequel parmi Triphala churna et le gluconate de chlorhexidine a une meilleure propriété antifongique sur le matériel de base de la prothèse de durcissement à chaud. Matériaux et Méthode: La population de l'étude était constituée de soixante porteurs de prothèses dentaires de ceux qui fréquentaient le Département de Prosthodontie de l'École des Sciences Dentaires de l'Institut Krishna des Sciences Médicales de l'Université de Karad. Des prélèvements ont été effectués sur les prothèses avant et après l'utilisation de Triphala et de chlorhexidine. On a cultivé les écouvillons sur de l'agar Sabouraud dextrose et on a déterminé le nombre total de candida. Triphala comme un anti fongique est démontré pour avoir plus d'efficacité que le lavage de la bouche classique chlorhexidine.

  9. Dissolution of cement, root caries, fracture, and retrofit of post and cores.

    PubMed

    Rosen, H

    1998-10-01

    Fixed partial denture abutments severely damaged by dental caries or fracture present a challenge to the dentist. The fixed partial denture may need to be removed for endodontic treatment with post and core fabrication. Frequently, the existing fixed partial denture can be recycled as a provisional restoration. Retrofitting the post and core greatly improves the stabilization of the interim as well as the remake of the definitive fixed partial denture. This article describes a chair side procedure for retrofitting posts and cores and, at the same appointment, converting the original fixed partial denture to an effective provisional restoration.

  10. Assessment of fire emission inventories during the South American Biomass Burning Analysis (SAMBBA) experiment

    NASA Astrophysics Data System (ADS)

    Pereira, Gabriel; Siqueira, Ricardo; Rosário, Nilton E.; Longo, Karla L.; Freitas, Saulo R.; Cardozo, Francielle S.; Kaiser, Johannes W.; Wooster, Martin J.

    2016-06-01

    Fires associated with land use and land cover changes release large amounts of aerosols and trace gases into the atmosphere. Although several inventories of biomass burning emissions cover Brazil, there are still considerable uncertainties and differences among them. While most fire emission inventories utilize the parameters of burned area, vegetation fuel load, emission factors, and other parameters to estimate the biomass burned and its associated emissions, several more recent inventories apply an alternative method based on fire radiative power (FRP) observations to estimate the amount of biomass burned and the corresponding emissions of trace gases and aerosols. The Brazilian Biomass Burning Emission Model (3BEM) and the Fire Inventory from NCAR (FINN) are examples of the first, while the Brazilian Biomass Burning Emission Model with FRP assimilation (3BEM_FRP) and the Global Fire Assimilation System (GFAS) are examples of the latter. These four biomass burning emission inventories were used during the South American Biomass Burning Analysis (SAMBBA) field campaign. This paper analyzes and inter-compared them, focusing on eight regions in Brazil and the time period of 1 September-31 October 2012. Aerosol optical thickness (AOT550 nm) derived from measurements made by the Moderate Resolution Imaging Spectroradiometer (MODIS) operating on board the Terra and Aqua satellites is also applied to assess the inventories' consistency. The daily area-averaged pyrogenic carbon monoxide (CO) emission estimates exhibit significant linear correlations (r, p > 0.05 level, Student t test) between 3BEM and FINN and between 3BEM_ FRP and GFAS, with values of 0.86 and 0.85, respectively. These results indicate that emission estimates in this region derived via similar methods tend to agree with one other. However, they differ more from the estimates derived via the alternative approach. The evaluation of MODIS AOT550 nm indicates that model simulation driven by 3BEM and FINN typically underestimate the smoke particle loading in the eastern region of Amazon forest, while 3BEM_FRP estimations to the area tend to overestimate fire emissions. The daily regional CO emission fluxes from 3BEM and FINN have linear correlation coefficients of 0.75-0.92, with typically 20-30 % higher emission fluxes in FINN. The daily regional CO emission fluxes from 3BEM_FRP and GFAS show linear correlation coefficients between 0.82 and 0.90, with a particularly strong correlation near the arc of deforestation in the Amazon rainforest. In this region, GFAS has a tendency to present higher CO emissions than 3BEM_FRP, while 3BEM_FRP yields more emissions in the area of soybean expansion east of the Amazon forest. Atmospheric aerosol optical thickness is simulated by using the emission inventories with two operational atmospheric chemistry transport models: the IFS from Monitoring Atmospheric Composition and Climate (MACC) and the Coupled Aerosol and Tracer Transport model to the Brazilian developments on the Regional Atmospheric Modelling System (CCATT-BRAMS). Evaluation against MODIS observations shows a good representation of the general patterns of the AOT550 nm time series. However, the aerosol emissions from fires with particularly high biomass consumption still lead to an underestimation of the atmospheric aerosol load in both models.

  11. Does Classification of Chronic Musculoskeletal Disorder Patients Into Psychosocial Subgroups Predict Differential Treatment Responsiveness and 1-Year Outcomes After a Functional Restoration Program?

    PubMed

    Asih, Sali; Mayer, Tom G; Williams, Mark; Choi, Yun Hee; Gatchel, Robert J

    2015-12-01

    The objectives of this study: (1) to assess whether Multidimensional Pain Inventory (MPI) profiles predicted differential responses to a functional restoration program (FRP) in chronic disabling occupational musculoskeletal disorder (CDOMD) patients; (2) to examine whether coping style improves following FRP; and (3) to determine whether discharge MPI profiles predict discharge psychosocial and 1-year socioeconomic outcomes. Consecutive CDOMD patients (N=716) were classified into Adaptive Coper (AC, n=209), Interpersonally Distressed (ID, n=154), Dysfunctional (DYS, n=310), and Anomalous (n=43) using the MPI, and reclassified at discharge. Profiles were compared on psychosocial measures and 1-year socioeconomic outcomes. An intent-to-treat sample analyzed the effect of drop-outs on treatment responsiveness. The MPI classification significantly predicted program completion (P=0.001), although the intent-to-treat analyses found no significant effects of drop-out on treatment responsiveness. There was a significant increase in the number of patients who became AC or Anomalous at FRP discharge and a decrease in those who were ID or DYS. Patients who changed or remained as DYS at FRP discharge reported the highest levels of pain, disability, and depression. No significant interaction effect was found between MPI group and time for pain intensity or disability. All groups improved on psychosocial measures at discharge. DYS patients had decreased work retention and a greater health care utilization at 1 year. An FRP was clinically effective for CDOMD patients regardless of initial MPI profiles. The FRP modified profiles, with patients changing from negative to positive profiles. Discharge DYS were more likely to have poor 1-year outcomes. Those classified as Anomalous had a good prognosis for functional recovery similar to ACs.

  12. Efficacy of bone substitute material in preserving volume when placing a maxillary immediate complete denture: study protocol for the PANORAMIX randomized controlled trial.

    PubMed

    Rignon-Bret, Christophe; Hadida, Alain; Aidan, Alexis; Nguyen, Thien-Huong; Pasquet, Gerard; Fron-Chabouis, Helene; Wulfman, Claudine

    2016-05-20

    Bone preservation is an essential issue in the context of last teeth extraction and complete edentulism. The intended treatment, whether a complete denture or an implant placement, is facilitated with a voluminous residual ridge. Bone resorption after multiple extractions has not been as well studied as the bone resorption that occurs after the extraction of a single tooth. Recent advances in bone substitute materials have revived this issue. The purpose of this study is to evaluate the interest in using bone substitute material to fill the socket after last teeth extraction in a maxillary immediate complete denture procedure compared with the conventional protocol without socket filling. A randomized, controlled, clinical trial was designed. The 34 participants eligible for maxillary immediate complete denture were divided into two groups. Complete dentures were prepared despite persistence of the last anterior teeth. The control group received a conventional treatment including denture placement immediately after extractions. In the experimental group, in addition to the immediate denture placement, a xenograft bone-substitute material (Bio-Oss Collagen®) was placed in the fresh sockets. The primary outcome of the study is to compare mean bone ridge height loss 1 year after maxillary immediate complete denture placement, with or without bone-substitute material, in incisor and canine sockets. The secondary outcomes are to compare the average bone ridge height and width loss for each extraction site. An original quantitative evaluation method using cone beam computed tomography was designed for reproducible measurements, with a radio-opaque denture duplicate. Two independent operators perform the radiologic measurements. The immediate complete denture technique limits bone resorption in multiple extraction situations and thus allows better denture retention and better options for implant placement. To compare the benefit of using any bone socket-filling material, we proposed a quantitative evaluation protocol of resorption in the specific case of the last anterior maxillary teeth extraction with immediate denture placement. ClinicalTrials.gov, NCT02120053 . Registered on 18 April 2014.

  13. [Oral rehabilitation with metalloceramic restorations in patients with non-differentiated systemic connective tissue dysplasia].

    PubMed

    Stafeev, А А

    2015-01-01

    False formation of connective tissues have a great influence on structure and function of organs and tissues of the human body. In prosthodontics, the changes in connective tissues greatly occur during clinical stages of preparing metal ceramic dentures. The algorithm of treatment patients with connective tissue dysplasia during metal ceramic dentures was developed and introduced into practical dentistry based on studying the morphology and functionality of dentition and clinical experience.

  14. Development of load and resistance factor design for FRP strengthening of reinforced concrete bridges.

    DOT National Transportation Integrated Search

    2006-05-01

    Externally bonded fiber reinforced polymer (FRP) composites are an increasingly adopted technology for the renewal of existing concrete structures. In order to encourage the further use of these materials, a design code is needed that considers the i...

  15. Assessment of mechanically fastened fiber reinforced polymer (MF-FRP) strips for extending bridge service life.

    DOT National Transportation Integrated Search

    2015-03-01

    The enhancement of load rating concrete structures by the installation of Fiber reinforced : polymer strips (FRP) is becoming a preferred short-term action. The addition of supplemental : tensile capacity to concrete beams by applying high tensile st...

  16. Plate & tube bridge deck evaluation in the deck test bed of the Troutville, Virginia, weigh station.

    DOT National Transportation Integrated Search

    2004-01-01

    This report addresses the laboratory and field performance of multi-cellular fiber-reinforced polymer (FRP) composite bridge deck systems. We focus specifically on FRP decks produced from adhesively bonded pultrusions where the core of the deck posse...

  17. Strengthening of Route 378 bridge over Wynantskill Creek in New York using FRP laminates

    DOT National Transportation Integrated Search

    2001-03-01

    This report describes application of Fiber-Reinforced Polymer (FRP) composite laminates to strengthen an aging reinforced-concrete T-beam bridge in South Troy, Rensselaer County, New York. Leakage at the end joints of this single-span structure led t...

  18. 46 CFR 160.135-11 - Fabrication of prototype lifeboats for approval.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... The Commandant may prescribe additional prototype tests and inspections necessary to maintain quality... inspecting— (i) Fiber Reinforced Plastic (FRP) Construction. (A) FRP components of each prototype lifeboat... system; (vii) Installation of the steering system; and (viii) Installation of the water spray fire...

  19. 46 CFR 160.135-11 - Fabrication of prototype lifeboats for approval.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... The Commandant may prescribe additional prototype tests and inspections necessary to maintain quality... inspecting— (i) Fiber Reinforced Plastic (FRP) Construction. (A) FRP components of each prototype lifeboat... system; (vii) Installation of the steering system; and (viii) Installation of the water spray fire...

  20. 46 CFR 160.135-11 - Fabrication of prototype lifeboats for approval.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... The Commandant may prescribe additional prototype tests and inspections necessary to maintain quality... inspecting— (i) Fiber Reinforced Plastic (FRP) Construction. (A) FRP components of each prototype lifeboat... system; (vii) Installation of the steering system; and (viii) Installation of the water spray fire...

  1. Evaluation of wearing surface materials for FRP bridge decks : final report.

    DOT National Transportation Integrated Search

    2005-07-01

    The wearing surface on many fiber reinforced polymer (FRP) composite bridge decks have cracked or delaminated after only a short time in service. Consequently, a set of tests were conducted on four wearing surface products in order to select the mate...

  2. A Review on Strengthening Steel Beams Using FRP under Fatigue

    PubMed Central

    Jumaat, Mohd Zamin; Ramli Sulong, N. H.

    2014-01-01

    In recent decades, the application of fibre-reinforced polymer (FRP) composites for strengthening structural elements has become an efficient option to meet the increased cyclic loads or repair due to corrosion or fatigue cracking. Hence, the objective of this study is to explore the existing FRP reinforcing techniques to care for fatigue damaged structural steel elements. This study covers the surface treatment techniques, adhesive curing, and support conditions under cyclic loading including fatigue performance, crack propagation, and failure modes with finite element (FE) simulation of the steel bridge girders and structural elements. FRP strengthening composites delay initial cracking, reduce the crack growth rate, extend the fatigue life, and decrease the stiffness decay with residual deflection. Prestressed carbon fibre-reinforced polymer (CFRP) is the best strengthening option. End anchorage prevents debonding of the CRRP strips at the beam ends by reducing the local interfacial shear and peel stresses. Hybrid-joint, nanoadhesive, and carbon-flex can also be attractive for strengthening systems. PMID:25243221

  3. Ultrasound assisted extraction of polyphenols and their distribution in whole mung bean, hull and cotyledon.

    PubMed

    Singh, Barinderjit; Singh, Narpinder; Thakur, Sheetal; Kaur, Amritpal

    2017-03-01

    In this study, extraction of polyphenols using different solvents (acetone, ethanol, methanol and water) with ultrasound and conventional method from whole mung bean (WMB), hull and cotyledon was conducted. Total phenolic content (TPC), total flavonoids content (TFC), total antioxidant activities (TAA), ferric reducing power (FRP) and DPPH radical scavenging activity were determined. Ultrasound treated extracts exhibited higher TPC, TFC, TAA, FRP and DPPH in different mung bean fractions than CSE. Among the solvents, acetone showed better TPC, TFC, TAA, FRP and DPPH. Hull had significantly higher TPC, TFC, TAA, FRP and DPPH than WMB and cotyledon. Sinapic acid (SA) was the major polyphenol in different fractions. Acetone extract of hull showed high polyphenol content. SA, ferulic acid, catechin, p-coumaric acid, resveratrol, quercetin and luteolin were the major contributors to antioxidant activity of acetone extract. Mung bean hull contained the maximum polyphenols and acetone was observed to be the best extraction medium for polyphenols in combination with ultrasound.

  4. Fluid shifts during thermal stress with and without fluid replacement

    NASA Technical Reports Server (NTRS)

    Myhre, L. G.; Robinson, S.

    1977-01-01

    Six unacclimatized men rested for 4 hr in a hot, dry environment without fluid replacement (DH). Another group of six men were exposed to the same thermal stress, replacing evaporative fluid loss with warm 0.1% NaCl solution (FRP). Total grams of circulating hemoglobin, determined by CO immediately prior to and again during the last minutes of heat exposure, increased an insignificant 1.6 and 1.3% during DH and FRP, respectively. With DH, body weight loss of 2.6% was accompanied by a 7.8% reduction in calculated plasma volume (PV). Even when body weight was maintained (FRP), PV decreased 2.9% during the heat exposure. Total circulating serum protein did not change as a result of the heat stress with either DH or FRP. In a test-retest series of experiments on four men, DH was not detrimental to sweat rate. It is shown that hemodilution is not a general response to acute heat exposure. The disproportionately large reduction in PV during thermal dehydration is confirmed.

  5. SIRT1 suppresses adipogenesis by activating Wnt/β-catenin signaling in vivo and in vitro

    PubMed Central

    Zhou, Yuanfei; Song, Tongxing; Peng, Jie; Zhou, Zheng; Wei, Hongkui; Zhou, Rui; Jiang, Siwen; Peng, Jian

    2016-01-01

    Sirtuin 1 (SIRT1) regulates adipocyte and osteoblast differentiation. However, the underlying mechanism should be investigated. This study revealed that SIRT1 acts as a crucial repressor of adipogenesis. RNA-interference-mediated SIRT1 knockdown or genetic ablation enhances adipogenic potential, whereas SIRT1 overexpression inhibits adipogenesis in mesenchymal stem cells (MSCs). SIRT1 also deacetylates the histones of sFRP1, sFRP2, and Dact1 promoters; inhibits the mRNA expression of sFRP1, sFRP2, and Dact1; activates Wnt signaling pathways; and suppresses adipogenesis. SIRT1 deacetylates β-catenin to promote its accumulation in the nucleus and thus induces the transcription of genes that block MSC adipogenesis. In mice, the partial absence of SIRT1 promotes the formation of white adipose tissues without affecting the development of the body of mice. Our study described the regulatory role of SIRT1 in Wnt signaling and proposed a regulatory mechanism of adipogenesis. PMID:27776347

  6. A review on strengthening steel beams using FRP under fatigue.

    PubMed

    Kamruzzaman, Mohamed; Jumaat, Mohd Zamin; Sulong, N H Ramli; Islam, A B M Saiful

    2014-01-01

    In recent decades, the application of fibre-reinforced polymer (FRP) composites for strengthening structural elements has become an efficient option to meet the increased cyclic loads or repair due to corrosion or fatigue cracking. Hence, the objective of this study is to explore the existing FRP reinforcing techniques to care for fatigue damaged structural steel elements. This study covers the surface treatment techniques, adhesive curing, and support conditions under cyclic loading including fatigue performance, crack propagation, and failure modes with finite element (FE) simulation of the steel bridge girders and structural elements. FRP strengthening composites delay initial cracking, reduce the crack growth rate, extend the fatigue life, and decrease the stiffness decay with residual deflection. Prestressed carbon fibre-reinforced polymer (CFRP) is the best strengthening option. End anchorage prevents debonding of the CRRP strips at the beam ends by reducing the local interfacial shear and peel stresses. Hybrid-joint, nanoadhesive, and carbon-flex can also be attractive for strengthening systems.

  7. Influence of length and diameter of implants associated with distal extension removable partial dentures.

    PubMed

    Verri, Fellippo Ramos; Pellizzer, Eduardo Piza; Rocha, Eduardo Passos; Pereira, João Antônio

    2007-09-01

    The aim of this study was to evaluate the influence of the length and diameter of the implant incorporated under the saddle of a distal-extension removable partial denture, acting as support. Six hemi-mandibular models were made with the presence of left inferior cuspid and first bicuspid, with the following differences: model A, without removable partial denture; model B, removable partial denture only; model C, removable partial denture and implant of 3.75 x x mm; model D, removable partial denture and implant of 3.75 x x3 mm; model E, removable partial denture and implant of 5 x x mm; and model F, removable partial denture and implant of 5 x x3 mm. These models were designed with the aid of AutoCAD 2000 (Autodesk, Inc., San Rafael, CA) and processed for finite element analysis by ANSYS 5.4 (Swanson Analysis Systems, Houston, PA). The loads applied were 50 N vertical on each cuspid point. It was noted that the presence of the removable partial denture overloaded the supporting tooth and other structures. The introduction of the implant reduced tensions, mainly at the extremities of the edentulous edge. Both the length and diameter tended to reduce tensions as their dimensions increased. Increasing the length of the implant had a great influence on the decrease of displacement and von Mises tension values. Increasing the diameter of the implant had a great influence on the decrease of von Mises tension values, but did not influence the displacement values. According to the results of this study, it is a good choice to use the greater and larger implant possible in the association between implant and distal extension removable partial denture.

  8. Effectiveness of Photodynamic Therapy for the Inactivation of Candida spp. on Dentures: In Vitro Study

    PubMed Central

    Mima, Ewerton Garcia de Oliveira; Ribeiro, Daniela Garcia; Dovigo, Livia Nordi; Vergani, Carlos Eduardo; Bagnato, Vanderlei Salvador

    2011-01-01

    Abstract Objective: This in vitro study evaluated the effectiveness of photodynamic therapy (PDT) for the inactivation of different species of Candida on maxillary complete dentures. Background data: The treatment of denture stomatitis requires the inactivation of Candida spp. on dentures. PDT has been reported as an effective method for Candida inactivation. Methods: Reference strains of C. albicans, C. glabrata, C. tropicalis, C. dubliniensis and C. krusei were tested. Thirty-four dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated with one of the strains and incubated at 37°C for 24 h. Dentures submitted to PDT (P+L+) were individually sprayed with 50 mg/L of Photogem® (PS) and, after 30 min, illuminated by LED light for 26 min (37.5 J/cm2). Additional dentures were treated only with PS (P+L-) or light (P-L+) or neither (P-L-). Samples of serial dilutions were spread on Sabouraud dextrose agar and incubated at 37°C for 48 h. The colonies were counted and the values of log (cfu/mL) were analyzed by Kruskall-Wallis and Dunn tests (p<0.05). Results: For all species of Candida, PDT resulted in significant reduction (p<0.05) of cfu/mL values from dentures when compared with P-L- (reductions from 1.73 to 3.99 log10). Significant differences (p<0.05), but lower reductions, were also observed for P+L- and P-L+when compared with P-L- for some species of Candida. Conclusions: PDT was an effective method for reducing Candida spp. on dentures. PMID:21916614

  9. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    PubMed

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p < 0.001). A 2 mm mean increase in OVD was observed in 47.7% of the dentures with < 6 occlusal contact changes and 88.9% of the dentures with ≥ 6 occlusal contact changes (p < 0.003). A significant change in the number of occlusal contacts was associated with an OVD increased up to two times. The short curing technique seems to be related to the decreased occlusal contacts and increased OVD. CLINICAL SIGNIFICANCES: More time is needed to adjust the occlusal errors of this method, because it has a negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  10. Inhibitory effect of zirconium oxide nanoparticles on Candida albicans adhesion to repaired polymethyl methacrylate denture bases and interim removable prostheses: a new approach for denture stomatitis prevention

    PubMed Central

    Gad, Mohammed M; Al-Thobity, Ahmad M; Shahin, Suliman Y; Alsaqer, Badar T; Ali, Aiman A

    2017-01-01

    Background Despite drawbacks, cold-cured acrylic resin is still the most common material used in denture repair. Zirconia nanoparticles were among the reinforcements added to increase the strength of the resin. The effect on Candida due to the addition of zirconia nanoparticles to the resin has not been investigated. Purpose The aim of this study was to evaluate the effect of zirconia nanoparticles added to cold-cured acrylic resin on Candida albicans adhesion. Materials and methods A total of 120 acrylic resin specimens with dimensions measuring 22×10×2.5 mm3 were prepared and divided into two equal groups. One group (repair) comprised heat-polymerized specimens that were sectioned at the center and prepared to create a 2 mm repair area that was repaired with cold-cured resin reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. The second group contained intact cold-cured acrylic resin specimens reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. Specimens were incubated at 37°C in artificial saliva containing C. albicans, and the effect of zirconia nanoparticles on C. albicans was assessed using two methods: 1) a slide count method and 2) a direct culture test. Variations in the number of living Candida were observed in relation to the different concentrations of zirconia nanoparticles. Analysis of variance (ANOVA) and post hoc Tukey’s tests were performed for data analysis. If the P-value was ≤0.05, then the difference was considered as statistically significant. Results It was found that C. albicans adhesion to repaired specimens was significantly decreased by the addition of zirconia nanoparticles (P<0.00001) in comparison with the control group. Intact cold-cured groups and groups repaired with cold-cured resin reinforced with 7.5% wt zirconia nanoparticles showed the lowest Candida count. Tukey’s test showed a significant difference between the repaired group and the intact cold-cured group, while the later demonstrated a lower Candida count. Conclusion The addition of zirconia nanoparticles to cold-cured acrylic resin is an effective method for reducing Candida adhesion to repaired polymethyl methacrylate (PMMA) denture bases and cold-cured removable prosthesis. Clinical significance Based on the results of the current study, zirconia nanoparticles have an antifungal effect, which could be incorporated in the repair material for repairing denture bases and in PMMA removable prostheses as a possible approach for denture stomatitis prevention. PMID:28814859

  11. Inhibitory effect of zirconium oxide nanoparticles on Candida albicans adhesion to repaired polymethyl methacrylate denture bases and interim removable prostheses: a new approach for denture stomatitis prevention.

    PubMed

    Gad, Mohammed M; Al-Thobity, Ahmad M; Shahin, Suliman Y; Alsaqer, Badar T; Ali, Aiman A

    2017-01-01

    Despite drawbacks, cold-cured acrylic resin is still the most common material used in denture repair. Zirconia nanoparticles were among the reinforcements added to increase the strength of the resin. The effect on Candida due to the addition of zirconia nanoparticles to the resin has not been investigated. The aim of this study was to evaluate the effect of zirconia nanoparticles added to cold-cured acrylic resin on Candida albicans adhesion. A total of 120 acrylic resin specimens with dimensions measuring 22×10×2.5 mm 3 were prepared and divided into two equal groups. One group (repair) comprised heat-polymerized specimens that were sectioned at the center and prepared to create a 2 mm repair area that was repaired with cold-cured resin reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. The second group contained intact cold-cured acrylic resin specimens reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. Specimens were incubated at 37°C in artificial saliva containing C. albicans , and the effect of zirconia nanoparticles on C. albicans was assessed using two methods: 1) a slide count method and 2) a direct culture test. Variations in the number of living Candida were observed in relation to the different concentrations of zirconia nanoparticles. Analysis of variance (ANOVA) and post hoc Tukey's tests were performed for data analysis. If the P -value was ≤0.05, then the difference was considered as statistically significant. It was found that C. albicans adhesion to repaired specimens was significantly decreased by the addition of zirconia nanoparticles ( P <0.00001) in comparison with the control group. Intact cold-cured groups and groups repaired with cold-cured resin reinforced with 7.5% wt zirconia nanoparticles showed the lowest Candida count. Tukey's test showed a significant difference between the repaired group and the intact cold-cured group, while the later demonstrated a lower Candida count. The addition of zirconia nanoparticles to cold-cured acrylic resin is an effective method for reducing Candida adhesion to repaired polymethyl methacrylate (PMMA) denture bases and cold-cured removable prosthesis. Based on the results of the current study, zirconia nanoparticles have an antifungal effect, which could be incorporated in the repair material for repairing denture bases and in PMMA removable prostheses as a possible approach for denture stomatitis prevention.

  12. Novel hybrid columns made of ultra-high performance concrete and fiber reinforced polymers

    NASA Astrophysics Data System (ADS)

    Zohrevand, Pedram

    The application of advanced materials in infrastructure has grown rapidly in recent years mainly because of their potential to ease the construction, extend the service life, and improve the performance of structures. Ultra-high performance concrete (UHPC) is one such material considered as a novel alternative to conventional concrete. The material microstructure in UHPC is optimized to significantly improve its material properties including compressive and tensile strength, modulus of elasticity, durability, and damage tolerance. Fiber-reinforced polymer (FRP) composite is another novel construction material with excellent properties such as high strength-to-weight and stiffness-to-weight ratios and good corrosion resistance. Considering the exceptional properties of UHPC and FRP, many advantages can result from the combined application of these two advanced materials, which is the subject of this research. The confinement behavior of UHPC was studied for the first time in this research. The stress-strain behavior of a series of UHPC-filled fiber-reinforced polymer (FRP) tubes with different fiber types and thicknesses were tested under uniaxial compression. The FRP confinement was shown to significantly enhance both the ultimate strength and strain of UHPC. It was also shown that existing confinement models are incapable of predicting the behavior of FRP-confined UHPC. Therefore, new stress-strain models for FRP-confined UHPC were developed through an analytical study. In the other part of this research, a novel steel-free UHPC-filled FRP tube (UHPCFFT) column system was developed and its cyclic behavior was studied. The proposed steel-free UHPCFFT column showed much higher strength and stiffness, with a reasonable ductility, as compared to its conventional reinforced concrete (RC) counterpart. Using the results of the first phase of column tests, a second series of UHPCFFT columns were made and studied under pseudo-static loading to study the effect of column parameters on the cyclic behavior of UHPCFFT columns. Strong correlations were noted between the initial stiffness and the stiffness index, and between the moment capacity and the reinforcement index. Finally, a thorough analytical study was carried out to investigate the seismic response of the proposed steel-free UHPCFFT columns, which showed their superior earthquake resistance, as compared to their RC counterparts.

  13. Rechargeable infection-responsive antifungal denture materials.

    PubMed

    Cao, Z; Sun, X; Yeh, C-K; Sun, Y

    2010-12-01

    Candida-associated denture stomatitis (CADS) is a significant clinical concern. We developed rechargeable infection-responsive antifungal denture materials for potentially managing the disease. Polymethacrylic acid (PMAA) was covalently bound onto diurethane dimethacrylate denture resins in the curing step. The PMAA resins bound cationic antifungal drugs such as miconazole and chlorhexidine digluconate (CG) through ionic interactions. The anticandidal activities of the drug-containing PMAA-resin discs were sustained for a prolonged period of time (weeks and months). Drug release was much faster at acidic conditions (pH 5) than at pH 7. Drugs bound to the denture materials could be "washed out" by treatment with EDTA, and the drug-depleted resins could be recharged with the same or a different class of anticandidal drugs. These results suggest clinical potential of the newly developed antifungal denture materials in the management of CADS and other infectious conditions.

  14. Inflammatory papillary hyperplasia: A systematic review

    PubMed Central

    Gual-Vaqués, Patricia; Jané-Salas, Enric; Egido-Moreno, Sonia; Ayuso-Montero, Raúl; Marí-Roig, Antoni

    2017-01-01

    Introduction Inflammatory papillary hyperplasia (IPH) is a benign lesion of the palatal mucosa. It is usually found in denture-wearers but also has been reported in patients without a history of use of a maxillary prosthesis use. Objetives The aim of this study is to review the literature to assess the prevalence of denture stomatitis and inflammatory papillary hyperplasia and the etiological factors associated. Material and Methods A search was carried out in PubMed (January 2005 to October 2015) with the key words “inflammatory papillary hyperplasia”, “denture stomatitis”, “granular stomatitis” and “Newton’s type III” The inclusion criteria were studies including at least a sample of 50 apparently healthy patients, articles published from 2005 to 2015 written in English. The exclusion criteria were reviews and non-human studies. Results Out of the 190 studies obtained initially from the search 16 articles were selected to be included in our systematic review. The prevalence of denture stomatitis was 29.56% and 4.44% for IPH. We found 5 cases of denture stomatitis among non-denture-wearer individuals. All IPH cases were associated with the use of prosthesis. Smoking and continued use of ill-fitting dentures turned out to be the most frequent risk factors for developing IPH. Conclusions IPH is a rare oral lesion and its pathogenesis still remains unclear. Its presentation among non-denture-wearers is extremely unusual. Key words:Inflammatory papillary hyperplasia, denture stomatitis, prevalence, granular stomatitis, Newton’s type III stomatitis. PMID:27918740

  15. VINEGAR AS AN ANTIMICROBIAL AGENT FOR CONTROL OF Candida spp. IN COMPLETE DENTURE WEARERS

    PubMed Central

    Pinto, Telma Maria Silva; Neves, Ana Christina Claro; Leão, Mariella Vieira Pereira; Jorge, Antonio Olavo Cardoso

    2008-01-01

    The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution (pH less than 3) overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests (germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation). The results were analyzed using Spearman's correlation and Student's t-test (p≤0.05). Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL) of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients. PMID:19082396

  16. Color stability of different denture teeth materials: an in vitro study.

    PubMed

    Mutlu-Sagesen, L; Ergün, G; Ozkan, Y; Bek, B

    2001-09-01

    The aim of this in vitro study was to compare the color stability of commercially available porcelain, reinforced acrylic, and conventional acrylic denture teeth materials used in removable prostheses. Two brands of porcelain (Unilux-Enta Lactona-Holland and Vivoperl-Ivoclar-Liechtenstein), 2 brands of reinforced acrylic (Optodent-Bayer-Germany and Ivolek-Ivoclar-Liechtenstein), and 2 brands of conventional acrylic (Isodent-Güney Diş Deposu-Turkey and Samed-Turkey), were made, for a total of 6 different denture teeth groups. Denture teeth were subjected to 3 staining solutions (filtered coffee, tea, and cola) and distilled water. From each group of denture teeth, 4 sets of maxillary anterior denture teeth were immersed in each of the 4 solutions. The color values of denture teeth were measured colorimetrically with the Gardner XL 20 Tristimulus Colorimeter (Gardner Lab. Inc., Bethesda, Maryland, USA). Color changes were characterized in the CIEL*a*b* color space. Color change values were determined after 1 day, 1 week, 2 weeks, and 4 weeks. The color difference values were calculated and then evaluated by two-way ANOVA statistically. The filtered coffee solution was found to be more chromogenic than the other 2 staining solutions, while porcelain denture teeth materials were more color stable. Assuming the color change of deltaE* < 1.0 as a discernible limit and deltaE* = 3.3 as an acceptable value, the filtered coffee, tea, and cola had slight staining effects on all 6 groups of denture teeth.

  17. Modeling delamination of FRP laminates under low velocity impact

    NASA Astrophysics Data System (ADS)

    Jiang, Z.; Wen, H. M.; Ren, S. L.

    2017-09-01

    Fiber reinforced plastic laminates (FRP) have been increasingly used in various engineering such as aeronautics, astronautics, transportation, naval architecture and their impact response and failure are a major concern in academic community. A new numerical model is suggested for fiber reinforced plastic composites. The model considers that FRP laminates has been constituted by unidirectional laminated plates with adhesive layers. A modified adhesive layer damage model that considering strain rate effects is incorporated into the ABAQUS / EXPLICIT finite element program by the user-defined material subroutine VUMAT. It transpires that the present model predicted delamination is in good agreement with the experimental results for low velocity impact.

  18. The importance of a two-step impression procedure for complete denture fabrication: a systematic review of the literature.

    PubMed

    Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M

    2016-10-01

    The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.

  19. The adhesive strength and initial viscosity of denture adhesives.

    PubMed

    Han, Jian-Min; Hong, Guang; Dilinuer, Maimaitishawuti; Lin, Hong; Zheng, Gang; Wang, Xin-Zhi; Sasaki, Keiichi

    2014-11-01

    To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.

  20. Relevance of Variations in the Opposing Dentition for the Functionality of Fixed and Removable Partial Dentures: A Systematic Review

    PubMed Central

    Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos

    2012-01-01

    The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a “biometric quality” tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture. PMID:23193407

Top