7. VIEW WEST OF SCALE ROOM IN FULLSCALE WIND TUNNEL; ...
7. VIEW WEST OF SCALE ROOM IN FULL-SCALE WIND TUNNEL; SCALES ARE USED TO MEASURE FORCES ACTING ON MODEL AIRCRAFT SUSPENDED ABOVE. - NASA Langley Research Center, Full-Scale Wind Tunnel, 224 Hunting Avenue, Hampton, Hampton, VA
11. VIEW LOOKING EAST AT MODEL AIRCRAFT CONTROL ROOM; MODEL ...
11. VIEW LOOKING EAST AT MODEL AIRCRAFT CONTROL ROOM; MODEL OF BOEING 737 AT TOP OF PHOTOGRAPH IN FULL-SCALE WIND TUNNEL. - NASA Langley Research Center, Full-Scale Wind Tunnel, 224 Hunting Avenue, Hampton, Hampton, VA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ronald L. Boring; Vivek Agarwal; Kirk Fitzgerald
2013-03-01
The U.S. Department of Energy’s Light Water Reactor Sustainability program has developed a control room simulator in support of control room modernization at nuclear power plants in the U.S. This report highlights the recent completion of this reconfigurable, full-scale, full-scope control room simulator buildout at the Idaho National Laboratory. The simulator is fully reconfigurable, meaning it supports multiple plant models developed by different simulator vendors. The simulator is full-scale, using glasstop virtual panels to display the analog control boards found at current plants. The present installation features 15 glasstop panels, uniquely achieving a complete control room representation. The simulator ismore » also full-scope, meaning it uses the same plant models used for training simulators at actual plants. Unlike in the plant training simulators, the deployment on glasstop panels allows a high degree of customization of the panels, allowing the simulator to be used for research on the design of new digital control systems for control room modernization. This report includes separate sections discussing the glasstop panels, their layout to mimic control rooms at actual plants, technical details on creating a multi-plant and multi-vendor reconfigurable simulator, and current efforts to support control room modernization at U.S. utilities. The glasstop simulator provides an ideal testbed for prototyping and validating new control room concepts. Equally importantly, it is helping create a standardized and vetted human factors engineering process that can be used across the nuclear industry to ensure control room upgrades maintain and even improve current reliability and safety.« less
Wall and corner fire tests on selected wood products
H. C. Tran; M. L. Janssens
1991-01-01
As part of a fire growth program to develop and validate a compartment fire model, several bench-scale and full-scale tests were conducted. This paper reports the full-scale wall and corner test results of step 2 of this study. A room fire test following the ASTM proposed standard specifications was used for these full-scale tests. In step 1, we investigated the...
NASA Technical Reports Server (NTRS)
Hillenbrand, L. J.; Wray, J. A.
1974-01-01
A program of experimental fires was carried out to establish the advantages offered by new materials for improved fire safety. Four full-scale bedrooms, differing only in the materials used to furnish them, were built and burned to provide comparative data on the fire hazards produced. Cost and availability differences were not considered. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. Resistance to the ignition and spread of fire was substantially improved in the rooms furnished completely or partially with the new materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanc, Katya; Joe, Jeffrey; Rice, Brandon
Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digitalmore » modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control room. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report describes the initial upgrades to the HSSL and outlines the methodology for a pilot test of the HSSL configuration.« less
A Research Framework for Demonstrating Benefits of Advanced Control Room Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanc, Katya; Boring, Ronald; Joe, Jeffrey
Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digitalmore » modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research presented here is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report serves as an outline for planned research on the benefits of greater modernization in the main control rooms of nuclear power plants.« less
Tritium, deuterium, and helium permeation through EPDM O-rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swansiger, W.A.
1992-03-01
This paper discusses tritium permeabilities determined at room temperature, 1.0 MPa (150 psia) tritium for three 23.4 cm diameter EPDM (ethylene-propylene-diene monomer) O-rings using a full-scale mock-up of the Al-SX shipping container seal geometry. The AL-SX container is being developed by Sandia National Laboratories for shipping tritium reservoirs. To determine the tritium permeation rate as a function of temperature, a 50.8 mm diameter EPDM O-ring was tested from room temperature to 150{degrees}C at a pressure of 1.0 MPa. Additional permeation measurements were made under the following test conditions: deuterium and helium-4 at room temperature and a pressure of 1.0 MPamore » using the full-scale AL-SX fixture, tritium from 0.1 MPa to 1.0 MPa at 142{degrees}C using the 50.8 mm fixture, and deuterium form room temperature to 150{degrees}C at a pressure of 1.0 MPa using the three full-scale O-rings showed the average room temperature, 1.0 MPa steady state tritium permeation rate to be about 1 {times} 10{sup {minus}2} Pa-liter/sec (7.6 {times} 10{sup {minus}5} torr-liter/sec or 1 {times} 10{sup {minus}4} std cc/sec), well within the allowable limit of 7.1 {times} 10{sup {minus}2} Pa-liter/sec for tritium release form the AL-SX container.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanc, Katya Lee; Bower, Gordon Ross; Hill, Rachael Ann
In order to provide a basis for industry adoption of advanced technologies, the Control Room Upgrades Benefits Research Project will investigate the benefits of including advanced technologies as part of control room modernization This report describes the background, methodology, and research plan for the first in a series of full-scale studies to test the effects of advanced technology in NPP control rooms. This study will test the effect of Advanced Overview Displays in the partner Utility’s control room simulator
Reaction-to-Fire of Wood Products and Other Building Materials: Part 1, Room/Corner Test Performance
Ondrej Grexa; Mark A. Dietenberger; Robert H. White
2012-01-01
This project researched the assessment of reaction-to-fire of common materials using the full-scale room/corner test (ISO 9705) protocol and the predictions of time to flashover using results from the bench-scale cone calorimeter test (ISO 5660-1). Using a burner protocol of 100 kW for 10 min, followed by 300 kW for 10 min and the test materials on the walls only, we...
NASA Technical Reports Server (NTRS)
Blunck, R. D.; Krantz, D. E.
1974-01-01
An account of activities and data gathered in the Room Temperature Stretch Forming of One-third Scale External Tank Bulkhead Gores for space shuttle study, and a tooling design and production cost study are reported. The following study phases are described: (1) the stretch forming of three approximately one-third scale external tank dome gores from single sheets of 2219-T37 aluminum alloy; (2) the designing of a full scale production die, including a determination of tooling requirements; and (3) the determination of cost per gore at the required production rates, including manufacturing, packaging, and shipping.
Tracking a head-mounted display in a room-sized environment with head-mounted cameras
NASA Astrophysics Data System (ADS)
Wang, Jih-Fang; Azuma, Ronald T.; Bishop, Gary; Chi, Vernon; Eyles, John; Fuchs, Henry
1990-10-01
This paper presents our efforts to accurately track a Head-Mounted Display (HMD) in a large environment. We review our current benchtop prototype (introduced in {WCF9O]), then describe our plans for building the full-scale system. Both systems use an inside-oui optical tracking scheme, where lateraleffect photodiodes mounted on the user's helmet view flashing infrared beacons placed in the environment. Church's method uses the measured 2D image positions and the known 3D beacon locations to recover the 3D position and orientation of the helmet in real-time. We discuss the implementation and performance of the benchtop prototype. The full-scale system design includes ceiling panels that hold the infrared beacons and a new sensor arrangement of two photodiodes with holographic lenses. In the full-scale system, the user can walk almost anywhere under the grid of ceiling panels, making the working volume nearly as large as the room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
BLanc, Katya Le; Powers, David; Joe, Jeffrey
2015-08-01
Control room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. Nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Upgrades in the U.S. do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The goal of the control room upgrade benefits research is to identify previously overlooked benefits of modernization, identify candidate technologiesmore » that may facilitate such benefits, and demonstrate these technologies through human factors research. This report describes a pilot study to test upgrades to the Human Systems Simulation Laboratory at INL.« less
Data reduction of room tests for zone model validation
M. Janssens; H. C. Tran
1992-01-01
Compartment fire zone models are based on many simplifying assumptions, in particular that gases stratify in two distinct layers. Because of these assumptions, certain model output is in a form unsuitable for direct comparison to measurements made in full-scale room tests. The experimental data must first be reduced and transformed to be compatible with the model...
Application of a finite-element model to low-frequency sound insulation in dwellings.
Maluski, S P; Gibbs, B M
2000-10-01
The sound transmission between adjacent rooms has been modeled using a finite-element method. Predicted sound-level difference gave good agreement with experimental data using a full-scale and a quarter-scale model. Results show that the sound insulation characteristics of a party wall at low frequencies strongly depend on the modal characteristics of the sound field of both rooms and of the partition. The effect of three edge conditions of the separating wall on the sound-level difference at low frequencies was examined: simply supported, clamped, and a combination of clamped and simply supported. It is demonstrated that a clamped partition provides greater sound-level difference at low frequencies than a simply supported. It also is confirmed that the sound-pressure level difference is lower in equal room than in unequal room configurations.
Thatcher, T L; Wilson, D J; Wood, E E; Craig, M J; Sextro, R G
2004-08-01
Scale modeling is a useful tool for analyzing complex indoor spaces. Scale model experiments can reduce experimental costs, improve control of flow and temperature conditions, and provide a practical method for pretesting full-scale system modifications. However, changes in physical scale and working fluid (air or water) can complicate interpretation of the equivalent effects in the full-scale structure. This paper presents a detailed scaling analysis of a water tank experiment designed to model a large indoor space, and experimental results obtained with this model to assess the influence of furniture and people in the pollutant concentration field at breathing height. Theoretical calculations are derived for predicting the effects from losses of molecular diffusion, small scale eddies, turbulent kinetic energy, and turbulent mass diffusivity in a scale model, even without Reynolds number matching. Pollutant dispersion experiments were performed in a water-filled 30:1 scale model of a large room, using uranine dye injected continuously from a small point source. Pollutant concentrations were measured in a plane, using laser-induced fluorescence techniques, for three interior configurations: unobstructed, table-like obstructions, and table-like and figure-like obstructions. Concentrations within the measurement plane varied by more than an order of magnitude, even after the concentration field was fully developed. Objects in the model interior had a significant effect on both the concentration field and fluctuation intensity in the measurement plane. PRACTICAL IMPLICATION: This scale model study demonstrates both the utility of scale models for investigating dispersion in indoor environments and the significant impact of turbulence created by furnishings and people on pollutant transport from floor level sources. In a room with no furniture or occupants, the average concentration can vary by about a factor of 3 across the room. Adding furniture and occupants can increase this spatial variation by another factor of 3.
Influence of room lighting on grey-scale perception with a CRT-and a TFT monitor display.
Haak, R; Wicht, M J; Hellmich, M; Nowak, G; Noack, M J
2002-05-01
To determine the influence of ambient lighting on grey-scale perception using a cathode-ray tube (CRT) and a thin film transistor (TFT) computer display. A cathode ray tube (Nokia XS 446) and a liquid crystal display (Panasonic LC 50S) were used at reduced room lighting (70 lux) and under conditions recommended for a dental operatory (1000 lux). Twenty-seven observers examined twice a modified SMPTE test pattern [0 to 255; 255 to 0] grey-scale values. The corresponding contrast differences were allocated to four ranges of grey levels (I: 0-63; II: 64-127; III: 128-191; IV: 192-255). The influences of monitor type, grey-scale range and illumination were evaluated by means of repeated measures analysis of variance. Detection of differences in monochromatic intensity was significantly earlier with reduced lighting (P<0.0001). When full ambient lighting was used, the TFT display was superior compared to the CRT monitor in ranges II and III (P<0.0001), whereas no differences could be detected for grey intensities between 0 and 63 (P=0.71) and between 192 and 255 (P=0.36). Background lighting hampers grey-scale perception on computer displays. In this study of one TFT and one CRT monitor, the TFT in full ambient lighting was associated with earlier detection of grey scale differences than CRT.
Western Aeronautical Test Range (WATR) mission control Blue room
1994-12-05
Mission control Blue Room, seen here, in building 4800 at NASA's Dryden Flight Research Center, is part of the Western Aeronautical Test Range (WATR). All aspects of a research mission are monitored from one of two of these control rooms at Dryden. The WATR consists of a highly automated complex of computer controlled tracking, telemetry, and communications systems and control room complexes that are capable of supporting any type of mission ranging from system and component testing, to sub-scale and full-scale flight tests of new aircraft and reentry systems. Designated areas are assigned for spin/dive tests, corridors are provided for low, medium, and high-altitude supersonic flight, and special STOL/VSTOL facilities are available at Ames Moffett and Crows Landing. Special use airspace, available at Edwards, covers approximately twelve thousand square miles of mostly desert area. The southern boundary lies to the south of Rogers Dry Lake, the western boundary lies midway between Mojave and Bakersfield, the northern boundary passes just south of Bishop, and the eastern boundary follows about 25 miles west of the Nevada border except in the northern areas where it crosses into Nevada.
Western Aeronautical Test Range (WATR) mission control Gold room
NASA Technical Reports Server (NTRS)
1990-01-01
Mission control Gold room is seen here, located at the Dryden Flight Research Center of the Western Aeronautical Test Range (WATR). All aspects of a research mission are monitored from one of two of these control rooms at Dryden. The WATR consists of a highly automated complex of computer controlled tracking, telemetry, and communications systems and control room complexes that are capable of supporting any type of mission ranging from system and component testing, to sub-scale and full-scale flight tests of new aircraft and reentry systems. Designated areas are assigned for spin/dive tests, corridors are provided for low, medium, and high-altitude supersonic flight, and special STOL/VSTOL facilities are available at Ames Moffett and Crows Landing. Special use airspace, available at Edwards, covers approximately twelve thousand square miles of mostly desert area. The southern boundary lies to the south of Rogers Dry Lake, the western boundary lies midway between Mojave and Bakersfield, the northern boundary passes just south of Bishop, and the eastern boundary follows about 25 miles west of the Nevada border except in the northern areas where it crosses into Nevada.
ERIC Educational Resources Information Center
Milshtein, Amy
1998-01-01
Describes how the Hammond School District (Indiana) solved the problem of fitting the correct amount of space needed for students, teachers, and technology. Examines the district's solutions for furniture needs through the use of full-scale mockups of classroom arrangements; and the wiring, power needs, and lighting. (GR)
Saarinen, Pekka E.; Kalliomäki, Petri; Tang, Julian W.; Koskela, Hannu
2015-01-01
The use of hospital isolation rooms has increased considerably in recent years due to the worldwide outbreaks of various emerging infectious diseases. However, the passage of staff through isolation room doors is suspected to be a cause of containment failure, especially in case of hinged doors. It is therefore important to minimize inadvertent contaminant airflow leakage across the doorway during such movements. To this end, it is essential to investigate the behavior of such airflows, especially the overall volume of air that can potentially leak across the doorway during door-opening and human passage. Experimental measurements using full-scale mock-ups are expensive and labour intensive. A useful alternative approach is the application of Computational Fluid Dynamics (CFD) modelling using a time-resolved Large Eddy Simulation (LES) method. In this study simulated air flow patterns are qualitatively compared with experimental ones, and the simulated total volume of air that escapes is compared with the experimentally measured volume. It is shown that the LES method is able to reproduce, at room scale, the complex transient airflows generated during door-opening/closing motions and the passage of a human figure through the doorway between two rooms. This was a basic test case that was performed in an isothermal environment without ventilation. However, the advantage of the CFD approach is that the addition of ventilation airflows and a temperature difference between the rooms is, in principle, a relatively simple task. A standard method to observe flow structures is dosing smoke into the flow. In this paper we introduce graphical methods to simulate smoke experiments by LES, making it very easy to compare the CFD simulation to the experiments. The results demonstrate that the transient CFD simulation is a promising tool to compare different isolation room scenarios without the need to construct full-scale experimental models. The CFD model is able to reproduce the complex airflows and estimate the volume of air escaping as a function of time. In this test, the calculated migrated air volume in the CFD model differed by 20% from the experimental tracer gas measurements. In the case containing only a hinged door operation, without passage, the difference was only 10%. PMID:26151865
Diode laser-based air mass flux sensor for subsonic aeropropulsion inlets
NASA Astrophysics Data System (ADS)
Miller, Michael F.; Kessler, William J.; Allen, Mark G.
1996-08-01
An optical air mass flux sensor based on a compact, room-temperature diode laser in a fiber-coupled delivery system has been tested on a full-scale gas turbine engine. The sensor is based on simultaneous measurements of O 2 density and Doppler-shifted velocity along a line of sight across the inlet duct. Extensive tests spanning engine power levels from idle to full afterburner demonstrate accuracy and precision of the order of 1 2 of full scale in density, velocity, and mass flux. The precision-limited velocity at atmospheric pressure was as low as 40 cm s. Multiple data-reduction procedures are quantitatively compared to suggest optimal strategies for flight sensor packages.
Analytical model of flame spread in full-scale room/corner tests (ISO9705)
Mark Dietenberger; Ondrej Grexa
1999-01-01
A physical, yet analytical, model of fire growth has predicted flame spread and rate of heat release (RHR) for an ISO9705 test scenario using bench-scale data from the cone calorimeter. The test scenario simulated was the propane ignition burner at the comer with a 100/300 kW program and the specimen lined on the walls only. Four phases of fire growth were simulated....
Preliminary metallographic studies of ball fatigue under rolling-contact conditions
NASA Technical Reports Server (NTRS)
Bear, H Robert; Butler, Robert H
1957-01-01
The metallurgical results produced on balls tested in the rolling-contact fatigue spin rig were studied by metallographic examination. Origin and progression of fatigue failures were observed. These evaluations were made on SAE 52100 and AISI M-1 balls fatigue tested at room temperature (80 F) and 200 to 250 F. Most failures originated subsurface in shear; inclusions, structure changes, and directionalism adversely affected ball fatigue life. Structures in the maximum-shear-stress region of the balls of both materials were stable at room temperature and unstable at 200 to 250 F. Failures were of the same type as those found in full-scale bearings.
Bayramzadeh, Sara; Joseph, Anjali; Allison, David; Shultz, Jonas; Abernathy, James
2018-07-01
This paper describes the process and tools developed as part of a multidisciplinary collaborative simulation-based approach for iterative design and evaluation of operating room (OR) prototypes. Full-scale physical mock-ups of healthcare spaces offer an opportunity to actively communicate with and to engage multidisciplinary stakeholders in the design process. While mock-ups are increasingly being used in healthcare facility design projects, they are rarely evaluated in a manner to support active user feedback and engagement. Researchers and architecture students worked closely with clinicians and architects to develop OR design prototypes and engaged clinical end-users in simulated scenarios. An evaluation toolkit was developed to compare design prototypes. The mock-up evaluation helped the team make key decisions about room size, location of OR table, intra-room zoning, and doors location. Structured simulation based mock-up evaluations conducted in the design process can help stakeholders visualize their future workspace and provide active feedback. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Codina, R.; Ambrosini, D.
2018-03-01
For the last few decades, the effects of blast loading on structures have been studied by many researchers around the world. Explosions can be caused by events such as industrial accidents, military conflicts or terrorist attacks. Urban centers have been prone to various threats including car bombs, suicide attacks, and improvised explosive devices. Partially vented constructions subjected to external blast loading represent an important topic in protective engineering. The assessment of blast survivability inside structures and the development of design provisions with respect to internal elements require the study of the propagation and leakage of blast waves inside buildings. In this paper, full-scale tests are performed to study the effects of the leakage of blast waves inside a partially vented room that is subjected to different external blast loadings. The results obtained may be useful for proving the validity of different methods of calculation, both empirical and numerical. Moreover, the experimental results are compared with those computed using the empirical curves of the US Defense report/manual UFC 3-340. Finally, results of the dynamic response of the front masonry wall are presented in terms of accelerations and an iso-damage diagram.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, C.; Spielman, Z.; LeBlanc, K.
An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collectmore » and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.« less
A HUMAN AUTOMATION INTERACTION CONCEPT FOR A SMALL MODULAR REACTOR CONTROL ROOM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanc, Katya; Spielman, Zach; Hill, Rachael
Many advanced nuclear power plant (NPP) designs incorporate higher degrees of automation than the existing fleet of NPPs. Automation is being introduced or proposed in NPPs through a wide variety of systems and technologies, such as advanced displays, computer-based procedures, advanced alarm systems, and computerized operator support systems. Additionally, many new reactor concepts, both full scale and small modular reactors, are proposing increased automation and reduced staffing as part of their concept of operations. However, research consistently finds that there is a fundamental tradeoff between system performance with increased automation and reduced human performance. There is a need to addressmore » the question of how to achieve high performance and efficiency of high levels of automation without degrading human performance. One example of a new NPP concept that will utilize greater degrees of automation is the SMR concept from NuScale Power. The NuScale Power design requires 12 modular units to be operated in one single control room, which leads to a need for higher degrees of automation in the control room. Idaho National Laboratory (INL) researchers and NuScale Power human factors and operations staff are working on a collaborative project to address the human performance challenges of increased automation and to determine the principles that lead to optimal performance in highly automated systems. This paper will describe this concept in detail and will describe an experimental test of the concept. The benefits and challenges of the approach will be discussed.« less
Demonstration of SiC Pressure Sensors at 750 C
NASA Technical Reports Server (NTRS)
Okojie, Robert S.; Lukco, Dorothy; Nguyen, Vu; Savrun, Ender
2014-01-01
We report the first demonstration of MEMS-based 4H-SiC piezoresistive pressure sensors tested at 750 C and in the process confirmed the existence of strain sensitivity recovery with increasing temperature above 400 C, eventually achieving near or up to 100% of the room temperature values at 750 C. This strain sensitivity recovery phenomenon in 4H-SiC is uncharacteristic of the well-known monotonic decrease in strain sensitivity with increasing temperature in silicon piezoresistors. For the three sensors tested, the room temperature full-scale output (FSO) at 200 psig ranged between 29 and 36 mV. Although the FSO at 400 C dropped by about 60%, full recovery was achieved at 750 C. This result will allow the operation of SiC pressure sensors at higher temperatures, thereby permitting deeper insertion into the engine combustion chamber to improve the accurate quantification of combustor dynamics.
Wang, Yong-Hui; Meng, Fei; Zhang, Yang; Xu, Mao-Yu; Yue, Shou-Wei
2016-06-01
To investigate whether full-movement neuromuscular electrical stimulation, which can generate full range of movement, reduces spasticity and/or improves motor function more effectively than control, sensory threshold-neuromuscular electrical stimulation, and motor threshold-neuromuscular electrical stimulation in sub-acute stroke patients. A randomized, single-blind, controlled study. Physical therapy room and functional assessment room. A total of 72 adult patients with sub-acute post-stroke hemiplegia and plantar flexor spasticity. Patients received 30-minute sessions of neuromuscular electrical stimulation on the motor points of the extensor hallucis and digitorum longus twice a day, five days per week for four weeks. Composite Spasticity Scale, Ankle Active Dorsiflexion Score, and walking time in the Timed Up and Go Test were assessed at pretreatment, posttreatment, and at two-week follow-up. After four weeks of treatment, when comparing interclass pretreatment and posttreatment, only the full-movement neuromuscular electrical stimulation group had a significant reduction in the Composite Spasticity Scale (mean % reduction = 19.91(4.96)%, F = 3.878, p < 0.05) and improvement in the Ankle Active Dorsiflexion Score (mean scores = 3.29(0.91), F = 3.140, p < 0.05). Furthermore, these improvements were maintained two weeks after the treatment ended. However, there were no significant differences in the walking time after four weeks of treatment among the four groups (F = 1.861, p > 0.05). Full-movement neuromuscular electrical stimulation with a stimulus intensity capable of generating full movement can significantly reduce plantar flexor spasticity and improve ankle active dorsiflexion, but cannot decrease walking time in the Timed Up and Go Test in sub-acute stroke patients. © The Author(s) 2015.
Instrumentation and data acquisition for full-scale aircraft crash testing
NASA Technical Reports Server (NTRS)
Jones, Lisa E.; Fasanella, Edwin L.
1993-01-01
The Landing and Impact Dynamics Branch of the NASA Langley Research Center has been conducting full-scale aircraft crash tests since the 1970s. Using a pendulum method, aircraft are suspended by cables from a 240-ft high gantry and swung into the impact surface at various attitudes and velocities. Instrumentation for these tests include on-board high-speed cameras, strain gages, load cells, displacement transducers, and accelerometers. Transducers in the aircraft are hard-wired through a long umbilical cable to the data acquisition room. Up to 96 channels of data can be collected at a typical rate of 4000 samples per second. Data acquisition using an FM multiplexed analog system and a high-speed personal computer based digital system is described.
Xu, Peng; Kujundzic, Elmira; Peccia, Jordan; Schafer, Millie P; Moss, Gene; Hernandez, Mark; Miller, Shelly L
2005-12-15
This study evaluated the efficacy of an upper-room air ultraviolet germicidal irradiation (UVGI) system for inactivating airborne bacteria, which irradiates the upper part of a room while minimizing radiation exposure to persons in the lower part of the room. A full-scale test room (87 m3), fitted with a UVGI system consisting of 9 louvered wall and ceiling fixtures (504 W all lamps operating) was operated at 24 and 34 degrees C, between 25 and 90% relative humidity, and at three ventilation rates. Mycobacterium parafortuitum cells were aerosolized into the room such that their numbers and physiologic state were comparable both with and without the UVGI system operating. Airborne bacteria were collected in duplicate using liquid impingers and quantified with direct epifluorescent microscopy and standard culturing assay. Performance of the UVGI system degraded significantly when the relative humidity was increased from 50% to 75-90% RH, the horizontal UV fluence rate distribution was skewed to one side compared to being evenly dispersed, and the room air temperature was stratified from hot at the ceiling to cold at the floor. The inactivation rate increased linearly with effective UV fluence rate up to 5 microW cm(-2); an increase in the fluence rate above this level did not yield a proportional increase in inactivation rate.
NASA Technical Reports Server (NTRS)
Hillenbrand, L. J.; Wray, J. A.
1973-01-01
The plans for the present series of full-scale experimental fires were initiated at the suggestion of NASA following the presentation of a film and discussion illustrating Battelle-Columbus' recent work in fire research. That film showed bedroom-type fires carried out as a part of a program to determine the influence of the cyclic characteristics of real fires under limited ventilation on the burning and pyrolysis properties of the room furnishings. A new series of fires was suggested by NASA designed to show the performance of new fire resistant and fire retardant materials by providing comparative fire and smoldering environmental conditions. More recently, the goal for the new series of fires was written in a meeting with NASA personnel and others at Battelle on May 3 and 4, 1972. The goal was as follows: To establish the need for special materials of improved fire safety in domiciliary settings of public concern, and to assess, in a professionally acceptable manner, the potential of materials arising from the new space-age technology for this purpose. It was anticipated that some new materials arising from the space-age technology and not yet available through conventional commercial channels might provide significant improvements in fire safety if the best of the commercially available materials showed important shortcomings in this area. It was the intent of this program to assess the benefits that could accrue from the use of these new materials. Fire safety is a matter requiring the evaluation of a number of factors. For example, fire resistance and fire spread, visibility during the fire, toxicity of evolved gases, and the fire-fighting problem that is created must be evaluated before the relative hazard can be assessed. The plan of the program provided for sampling and instrumentation to evaluate these factors, consistent with the goal of technological utilization that has been specified. Arrangements were made with the Columbus Fire Department to use an existing six-story concrete building', designed and used as a fire training tower, as the site for the experimental fires. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. In particular: (1) The Typical room, furnished from conventional retail sources, ignited easily and burned rapidly so that after 8 minutes the contents of the room were nearly destroyed. (2) The Improved room, furnished with materials selected as being among the best commercially available, showed substantial improvement over the Typical room in that there was slower fire spread. However, the relatively complete destruction of the room contents that resulted, and the large amounts of smoke, made it clear that substantial further improvements were needed. This fire was stopped after 29 minutes. (3) The Space-age room, furnished completely with new materials that were not yet commercially available, did not ignite under the common ignition condition and soon demonstrated the substantial improvement in fire resistance available for those components close to the ignition source. A second and larger ignition arrangement showed that this room can burn, but the difficulty with which this was brought about confirmed the improved fire resistance available with use of these materials. (4) The Mixed room ensemble, furnished with 'materials identical to the Typical room except for the substitution of the bed from the Space-age room, illustrated the improvement in control of fire spread available by careful placement of fire materials in the important paths of fire development of an otherwise ordinary room. The most significant hazards at early times in each fire were due to the rapid rise in heat flux and the abrupt obscuration of vision by smoke. The most consistent toxicity hazard was due to CO and its importance would depend on the ability of the occupant to survive the initial heat and smoke menace which characterized each fire room. Other gases and vapors were shown to reach hazardous levels in certain fire rooms and, again, their significance to an occupant, would relate to the times in which such hazards occurred, and probably to the synergistic nature of the hazard arising from mixtures of such gases. Fire retardant items in the room are caused to pyrolyze by the heat of burning from other items in the room and so contribute to combustible and toxic vapor accumulations, even though they may not have entered into the burning process. This effect of a mixture of combustible materials to produce burning and pyrolysis not characteristic of any one item individually we have chosen to call the "ensemble effect". Further full-scale fire trials may be expected to show the significant changes that control the burning and pyrolytic processes and in that event a programmed fire chamber should be developed to yield realistic laboratory results.
Use of automatic door closers improves fire safety.
Waterman, T E
1979-01-01
In a series of 16 full-scale fire tests, investigators at the IIT Research Institute have concluded that automatic door control in the room of fire origin can significantly reduce the spread of toxic smoke and gases. The researchers also investigated the effects of sprinkler actuation, and the functional relationship between sprinklers and automatic door closers. This report presents the results of the study, and presents recommendations for health-care facilities.
Pressure Decay Testing Methodology for Quantifying Leak Rates of Full-Scale Docking System Seals
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H., Jr.; Daniels, Christopher C.; Wasowski, Janice L.; Garafolo, Nicholas G.; Penney, Nicholas; Steinetz, Bruce M.
2010-01-01
NASA is developing a new docking system to support future space exploration missions to low-Earth orbit and the Moon. This system, called the Low Impact Docking System, is a mechanism designed to connect the Orion Crew Exploration Vehicle to the International Space Station, the lunar lander (Altair), and other future Constellation Project vehicles. NASA Glenn Research Center is playing a key role in developing the main interface seal for this docking system. This seal will be relatively large with an outside diameter in the range of 54 to 58 in. (137 to 147 cm). As part of this effort, a new test apparatus has been designed, fabricated, and installed to measure leak rates of candidate full-scale seals under simulated thermal, vacuum, and engagement conditions. Using this test apparatus, a pressure decay testing and data processing methodology has been developed to quantify full-scale seal leak rates. Tests performed on untreated 54 in. diameter seals at room temperature in a fully compressed state resulted in leak rates lower than the requirement of less than 0.0025 lbm, air per day (0.0011 kg/day).
Methods for Evaluating Flammability Characteristics of Shipboard Materials
1994-02-28
E 23 • smoke optical properties; and • (toxic) gas production rates. In general, the prediction of these full-scale burning characteristics requires ...Method. The ASTM Room/Corner Test Method can be used to calculate the heat release rate of a material based upon oxygen depletion calorimetry. As can be...Clearly, more validation is required for the theoretical calculations . All are consistent in the use of calorimeter and UFT-type property data, all show
Teachers' Rooms Environmental Assessment Scale: Development and Psychometric Evaluation
ERIC Educational Resources Information Center
Arslan, Suna
2016-01-01
Teachers' rooms are important parts of educational environments, as the quality of the physical-spatial and psychosocial conditions may affect the personal and occupational developments of teachers as well as the education processes. In Study 1 (n = 245), a Teachers' Rooms-Environmental Assessment Scale (TREAS) measure of the current conditions of…
MNASA as a Test for Carbon Fiber Thermal Barrier Development
NASA Technical Reports Server (NTRS)
Bauer, Paul; McCool, Alex (Technical Monitor)
2001-01-01
A carbon fiber rope thermal barrier is being evaluated as a replacement for the conventional room temperature vulcanizing (RTV) thermal barrier that is currently used to protect o-rings in Reusable Solid Rocket Motor (RSRM) nozzle joints. Performance requirements include its ability to cool any incoming, hot propellant gases that fill and pressurize the nozzle joints, filter slag and particulates, and to perform adequately in various joint assembly conditions as well as dynamic flight motion. Modified National Aeronautics and Space Administration (MNASA) motors, with their inherent and unique ability to replicate select RSRM internal environment features, were an integral step in the development path leading to full scale RSRM static test demonstration of the carbon fiber rope (CFR) joint concept. These 1/4 scale RSRM motors serve to bridge the gap between the other classes of subscale test motors (extremely small and moderate duration, or small scale and short duration) and the critical asset RSRM static test motors. A series of MNASA tests have been used to demonstrate carbon fiber rope performance and have provided rationale for implementation into a full-scale static motor and flight qualification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spielman, Zachary; Hill, Racheal; LeBlanc, Katya
Control room modernization is critical to extending the life of the 99 operating commercial nuclear power plants (NPP) within the United States. However, due to the lack of evidence demonstrating the efficiency and effectiveness of recent candidate technologies, current NPP control rooms operate without the benefit of various newer technologies now available. As nuclear power plants begin to extend their licenses to continue operating for another 20 years, there is increased interest in modernizing the control room and supplementing the existing control boards with advanced technologies. As part of a series of studies investigating the benefits of advanced control roommore » technologies, the researchers conducted an experimental study to observe the effect of Task-Based Overview Displays (TODs) on operator workload and situation awareness (SA) while completing typical operating scenarios. Researchers employed the Situation Awareness Rating Technique (SART) and the NASA Task Load Index (TLX) as construct measures.« less
Basson, Marc D; Butler, Timothy
2006-11-01
Operating room (OR) activity transcends single ratios such as cases/room, but weighting multiple inputs and outputs may be arbitrary. Data-envelopment analysis (DEA) is a novel technique by which each facility is analyzed by the weightings that optimize its score. We performed DEA analysis of 23 Veterans Health Administration annual OR activity; 87,180 cases were performed, 24 publications generated, and 560 trainee-years of education delivered, in 168 ORs over 166,377 hours by 1,384 full-time equivalents of surgical and anesthesia providers and 523 nonproviders. Varying analyzed parameters produced similar efficiency rankings, with individual differences suggesting possible inefficiencies. We characterized returns to scale for efficient sites, suggesting whether patient flow might be efficiently further increased through these sites. We matched inefficient sites to similar efficient sites for comparison and suggested resource alterations to increase efficiency. Broader DEA application might characterize OR efficiency more informatively than conventional single-ratio rank ordering.
NASA Technical Reports Server (NTRS)
Finger, R. W.
1974-01-01
The effects of proof overload frequency and magnitude on the cyclic crack growth rates of 304 stainless steel weldments were investigated. The welding procedure employed was typical of those used on over-the-road cryogenic vessels. Tests were conducted at room temperature with an overload ratio of 1.50 to determine the effect of overload frequency. Effect of overload magnitude was determined from tests where a room temperature overload was applied between blocks of 1000 cycles applied at 78 K (-320 F). The cyclic stress level used in all tests was typical of the nominal membrane stress generally encountered in full scale vessels. Test results indicate that judicious selection of proof overload frequency and magnitude can reduce crack growth rates for cyclic stress levels.
Weight loss and jaundice in healthy term newborns in partial and full rooming-in.
Zuppa, Antonio Alberto; Sindico, Paola; Antichi, Eleonora; Carducci, Chiara; Alighieri, Giovanni; Cardiello, Valentina; Cota, Francesco; Romagnoli, Costantino
2009-09-01
An inadequate start of breastfeeding has been associated with reduced caloric intake, excessive weight loss and high serum bilirubin levels in the first days of life. The rooming-in has been proposed as an optimal model for the promotion of breastfeeding. The aim of this study was to compare two different feeding models (partial and full rooming-in) to evaluate differences as regard to weight loss, hyperbilirubinemia and prevalence of exclusive breastfeeding at discharge. A total of 903 healthy term newborns have been evaluated; all the newborns were adequate for gestational age, with birth weight > or = 2800 g and gestational age > or = 37 weeks. The maximum weight loss (mean +/- SD), expressed as percent of birth weight, was not different in the two models (partial vs. full rooming-in 5.8% +/- 1.7%vs. 6% +/- 1.7%). A weight loss > or = 10% occurred in less than 1% in both groups. There were no statistical differences neither as mean of total serum bilirubin (partial vs. full rooming-in 10.5 +/- 3.3 vs. 10.1 +/- 2.9 mg/dl), nor as prevalence of hyperbilirubinemia (total serum bilirubin > or = 12 mg/dl). The prevalence of severe hyperbilirubinemia (total serum bilirubin > or = 18 mg/dl) and the use of phototherapy were not statistically different. Maximum weight loss was similar in the two models, even dividing by total serum bilirubin levels. At the discharge, exclusively breastfed newborns were 81% in full rooming-in and 42.9% in partial rooming-in. In conclusion, our results allow considering our assistance models similar as regards to severe hyperbilirubinemia and pathological weight loss in term healthy newborns even if full rooming-in is associated with higher prevalence of exclusive breastfeeding at the discharge.
Design, construction, and evaluation of a 1:8 scale model binaural manikin.
Robinson, Philip; Xiang, Ning
2013-03-01
Many experiments in architectural acoustics require presenting listeners with simulations of different rooms to compare. Acoustic scale modeling is a feasible means to create accurate simulations of many rooms at reasonable cost. A critical component in a scale model room simulation is a receiver that properly emulates a human receiver. For this purpose, a scale model artificial head has been constructed and tested. This paper presents the design and construction methods used, proper equalization procedures, and measurements of its response. A headphone listening experiment examining sound externalization with various reflection conditions is presented that demonstrates its use for psycho-acoustic testing.
FY15 Report on Thermomechanical Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, Francis D.; Buchholz, Stuart
2015-08-01
Sandia is participating in the third phase of a United States (US)-German Joint Project that compares constitutive models and simulation procedures on the basis of model calculations of the thermomechanical behavior and healing of rock salt (Salzer et al. 2015). The first goal of the project is to evaluate the ability of numerical modeling tools to correctly describe the relevant deformation phenomena in rock salt under various influences. Among the numerical modeling tools required to address this are constitutive models that are used in computer simulations for the description of the thermal, mechanical, and hydraulic behavior of the host rockmore » under various influences and for the long-term prediction of this behavior. Achieving this goal will lead to increased confidence in the results of numerical simulations related to the secure disposal of radioactive wastes in rock salt. Results of the Joint Project may ultimately be used to make various assertions regarding stability analysis of an underground repository in salt during the operating phase as well as long-term integrity of the geological barrier in the post-operating phase A primary evaluation of constitutive model capabilities comes by way of predicting large-scale field tests. The Joint Project partners decided to model Waste Isolation Pilot Plant (WIPP) Rooms B & D which are full-scale rooms having the same dimensions. Room D deformed under natural, ambient conditions while Room B was thermally driven by an array of waste-simulating heaters (Munson et al. 1988; 1990). Existing laboratory test data for WIPP salt were carefully scrutinized and the partners decided that additional testing would be needed to help evaluate advanced features of the constitutive models. The German partners performed over 140 laboratory tests on WIPP salt at no charge to the US Department of Energy (DOE).« less
Experimental Plan for Crystal Accumulation Studies in the WTP Melter Riser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D.; Fowley, M.
2015-04-28
This experimental plan defines crystal settling experiments to be in support of the U.S. Department of Energy – Office of River Protection crystal tolerant glass program. The road map for development of crystal-tolerant high level waste glasses recommends that fluid dynamic modeling be used to better understand the accumulation of crystals in the melter riser and mechanisms of removal. A full-scale version of the Hanford Waste Treatment and Immobilization Plant (WTP) melter riser constructed with transparent material will be used to provide data in support of model development. The system will also provide a platform to demonstrate mitigation or recoverymore » strategies in off-normal events where crystal accumulation impedes melter operation. Test conditions and material properties will be chosen to provide results over a variety of parameters, which can be used to guide validation experiments with the Research Scale Melter at the Pacific Northwest National Laboratory, and that will ultimately lead to the development of a process control strategy for the full scale WTP melter. The experiments described in this plan are divided into two phases. Bench scale tests will be used in Phase 1 (using the appropriate solid and fluid simulants to represent molten glass and spinel crystals) to verify the detection methods and analytical measurements prior to their use in a larger scale system. In Phase 2, a full scale, room temperature mockup of the WTP melter riser will be fabricated. The mockup will provide dynamic measurements of flow conditions, including resistance to pouring, as well as allow visual observation of crystal accumulation behavior.« less
Field modeling of heat transfer in atrium
NASA Astrophysics Data System (ADS)
Nedryshkin, Oleg; Gravit, Marina; Bushuev, Nikolay
2017-10-01
The results of calculating fire risk are an important element in the system of modern fire safety assessment. The article reviews the work on the mathematical modeling of fire in the room. A comparison of different calculation models in the programs of fire risk assessment and fire modeling was performed. The results of full-scale fire tests and fire modeling in the FDS program are presented. The analysis of empirical and theoretical data on fire modeling is made, a conclusion is made about the modeling accuracy in the FDS program.
Andersen, Simone Nyholm; Broberg, Ole
2015-11-01
Current application of work system simulation in participatory ergonomics (PE) design includes a variety of different simulation media. However, the actual influence of the media attributes on the simulation outcome has received less attention. This study investigates two simulation media: full-scale mock-ups and table-top models. The aim is to compare, how the media attributes of fidelity and affordance influence the ergonomics identification and evaluation in PE design of hospital work systems. The results illustrate, how the full-scale mock-ups' high fidelity of room layout and affordance of tool operation support ergonomics identification and evaluation related to the work system entities space and technologies & tools. The table-top models' high fidelity of function relations and affordance of a helicopter view support ergonomics identification and evaluation related to the entity organization. Furthermore, the study addresses the form of the identified and evaluated conditions, being either identified challenges or tangible design criteria. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Interior of processing room. Scale is in front of windows ...
Interior of processing room. Scale is in front of windows for weighing shuckers' buckets of oyster meat. Blow tank for thoroughly cleaning the oyster meat and two skimming tables for rinsing and draining can also be seen. - J.C. Lore Oyster House, 14430 Solomons Island Road, Solomons, Calvert County, MD
Development of Trace Contaminant Control Prototypes for the Primary Life Support System (PLSS)
NASA Technical Reports Server (NTRS)
Wojtowicz, Marek; Cosgrove, Joseph E.; Serio, Michael E.; Nalette, Tim; Guerrero, Sandra V.; Papale, William; Wilburn, Monique S.
2017-01-01
Results are presented on the development of Trace Contaminant Control (TCC) Prototypes for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is non-regenerable, and the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on sorption and desorption of ammonia and formaldehyde, which are major TCs of concern, as well as pressure-drop calculations were used to design and test 1/6-scale and full-scale trace contaminant control system (TCCS) prototypes. Carbon sorbents were fabricated in both the granular and foam-supported forms. Sorbent performance was tested for ammonia sorption and vacuum regeneration in 1/6-scale, and pressure-drop characteristics were measured at flow rates relevant to the PLSS application.
Assessment of Suicidal Behavior in a Psychiatric Emergency Room in Lisbon.
Marques, João Gama; Guerreiro, Diogo Frasquilho; Sampaio, Daniel
2015-01-01
Some studies alerted for the burden of suicidal attempters at emergency rooms. In this study we characterized the suicidal patients admitted to a Portuguese emergency room. For three years, all patients assessed by the first author after suicidal behaviour were included. Suicidal intentionality was evaluated with the Pierce Suicide Intent Scale. Clinical records were searched for follow-up status and satisfaction level was assessed through telephone call. From 120 included patients 70.8% were female, with mean age of 42.35 years. Pierce Suicide Intent Scale suicidal intentionality was low in 30.1%, medium in 59.3%, and high in 10.6% of the sample. The most important predictors of Pierce Suicide Intent Scale intentionality were male gender (p < 0.001), family history of suicide (p < 0.01), divorced or widowed marital status (p < 0.013), and severe mental illness (p < 0.015). In 41.6% of the patients the follow-up status was unknown. Regarding satisfaction, only 19.5% gave a valid answer: 2.7% 'mildly satisfied', 4.4% 'moderately satisfied', and 12.5% 'very satisfied'. The Pierce Suicide Intent Scale is useful on suicidal behavior assessment at emergency rooms. Highly intentional suicidal behaviour is related to male sex, social problems and personal and familial psychiatric history. The quality of administrative records on this psychiatric emergency room setting are still unacceptable. The most important variables correlated with higher suicidal intentionality are the same described in other countries. Of the reachable patients, one fifth was satisfied with provided follow-up. We still need studies for better understanding of suicidal behaviour observed on this Portuguese emergency room.
Eliciting Unstated Requirements at Scale
2014-10-23
decide about food and snacks while working in my room 12 Attractive Furnishings put me in an energetic mood, enabling me to get more work done in my...me choices as I decide about food and snacks while working in my room 10 Good Room Service Selection keeps my stress level down and reduces
Comfort and Accessibility Evaluation of Light Rail Vehicles
NASA Astrophysics Data System (ADS)
Hirasawa, Takayuki; Matsuoka, Shigeki; Suda, Yoshihiro
A quantitative evaluation method for passenger rooms of light rail vehicles from viewpoint of comfort and accessibility is proposed as the result of physical modeling of in-vehicle behavior of passengers upon Gibson's ecological psychology approach. The model parameters are identified from experiments at real vehicles at the depot of Kumamoto municipal transport and at the full-scale mockup of the University of Tokyo. The developed model has realized quantitative evaluation of floor lowering effects by abolishing internal steps at passenger doorways and door usage restriction scenarios from viewpoint of both passengers and operators in comparison to commuter railway vehicles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K.; Fowley, M.
A full-scale, transparent mock-up of the Hanford Tank Waste Treatment and Immobilization Project High Level Waste glass melter riser and pour spout has been constructed to allow for testing with visual feedback of particle settling, accumulation, and resuspension when operating with a controlled fraction of crystals in the glass melt. Room temperature operation with silicone oil and magnetite particles simulating molten glass and spinel crystals, respectively, allows for direct observation of flow patterns and settling patterns. The fluid and particle mixture is recycled within the system for each test.
Minutes of the 23rd Eplosives Safety Seminar, volume 2
NASA Astrophysics Data System (ADS)
1988-08-01
Some areas of discussion at this seminar were: Hazards and risks of the disposal of chemical munitions using a cryogenic process; Special equipment for demilitarization of lethal chemical agent filled munitions; explosive containment room (ECR) repair Johnston Atoll chemical agent disposal system; Sympathetic detonation testing; Blast loads, external and internal; Structural reponse testing of walls, doors, and valves; Underground explosion effects, external airblast; Explosives shipping, transportation safety and port licensing; Explosive safety management; Underground explosion effects, model test and soil rock effects; Chemical risk and protection of workers; and Full scale explosives storage test.
Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thanachareonkit, Anothai; Lee, Eleanor S.; McNeil, Andrew
2013-08-31
Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in amore » sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the redirected light spreading it within a small range of outgoing angles. This solution was found to reduce glare to imperceptible levels while retaining for the most part the illuminance levels achieved solely by the daylighting film.« less
Galileo Galilei (GG): the space mission and the prototype
NASA Astrophysics Data System (ADS)
Nobili, A.
"GALILEO GALILEI (GG)" is a proposal to fly a small satellite in low Earth orbit aiming to test the Equivalence Principle of Galileo, Newton and Einstein to 1 part in 1017 at room temperature. Ground tests carried out with artificial test bodies on rotating torsion balances, and tests with celestial bodies based on Lunar Laser Ranging data, have found no violation to about 1 part in 1013 . Competing space pro jects are SCOPE (also at room temperature) aiming to 1 part in 1015 , and STEP (at very low temperature) aiming to 1 part in 1018 . GG is characterized by fast rotation and by the possibility to perform a full scale test on the ground. This talk will present the main features of the GG design, as compared to STEP and SCOPE, and report the experimental results obtained with the first and the second generation laboratory prototypes (natural frequencies, quality factor, stability, sensitivity). Interested scientists are welcome to visit the GG webpage at http://eotvos.dm.unipi.it/nobili.
State-resolved Thermal/Hyperthermal Dynamics of Atmospheric Species
2015-06-23
gas -room temperature ionic liquid (RTIL) interfaces. 2) Large scale trajectory simulations for theoretical analysis of gas - liquid scattering studies...areas: 1) Diode laser and LIF studies of hyperthermal CO2 and NO collisions at the gas -room temperature ionic liquid (RTIL) interfaces. 2) Large...scale trajectory simulations for theoretical analysis of gas - liquid scattering studies, 3) LIF data for state-resolved scattering of hyperthermal NO at
Looking Northwest at Office Building Boiler Room, Including Cinderblock Walls, ...
Looking Northwest at Office Building Boiler Room, Including Cinderblock Walls, Fuel Tank and Scale Weights - Hematite Fuel Fabrication Facility, Office, 3300 State Road P, Festus, Jefferson County, MO
The Helmholtz resonance behavior of single and multiple rooms
NASA Technical Reports Server (NTRS)
Hubbard, H. H.; Shepherd, K. P.
1986-01-01
The results of exploratory measurements of the noise fields inside rooms which are excited to resonance either acoustically or mechanically are presented. The data illustrate the nature and extent of the sound pressure level enhancements in single rooms and also how multiple rooms may resonate by means of either acoustic or mechanical coupling. Sound pressure level enhancements of about 5 dB were measured during resonance of rooms having flexible walls. For such conditions the sound pressure levels in the room were essentially uniform and in phase. Variability of up to 20 dB was measured in a room hallway complex having significant acoustic interactions. Resonant frequency prediction methods which work well at model scale, give only fair results for rooms.
Altitude Wind Tunnel Control Room at the Aircraft Engine Research Laboratory
1944-07-21
Operators in the control room for the Altitude Wind Tunnel at the National Advisory Committee for Aeronautics (NACA) Aircraft Engine Research Laboratory remotely operate a Wright R–3350 engine in the tunnel’s test section. Four of the engines were used to power the B–29 Superfortress, a critical weapon in the Pacific theater during World War II. The wind tunnel, which had been in operation for approximately six months, was the nation’s only wind tunnel capable of testing full-scale engines in simulated altitude conditions. The soundproof control room was used to operate the wind tunnel and control the engine being run in the test section. The operators worked with assistants in the adjacent Exhauster Building and Refrigeration Building to manage the large altitude simulation systems. The operator at the center console controlled the tunnel’s drive fan and operated the engine in the test section. Two sets of pneumatic levers near his right forearm controlled engine fuel flow, speed, and cooling. Panels on the opposite wall, out of view to the left, were used to manage the combustion air, refrigeration, and exhauster systems. The control panel also displayed the master air speed, altitude, and temperature gauges, as well as a plethora of pressure, temperature, and airflow readings from different locations on the engine. The operator to the right monitored the manometer tubes to determine the pressure levels. Despite just being a few feet away from the roaring engine, the control room remained quiet during the tests.
Ni, Zhe; Liu, Jianguo; Song, Mingying; Wang, Xiaowei; Ren, Lianhai; Kong, Xin
2015-03-01
Food waste treatment plants (FWTPs) are usually associated with odorous nuisance and health risks, which are partially caused by volatile organic compound (VOC) emissions. This study investigated the VOC emissions from a selected full-scale FWTP in China. The feedstock used in this plant was mainly collected from local restaurants. For a year, the FWTP was closely monitored on specific days in each season. Four major indoor treatment units of the plant, including the storage room, sorting/crushing room, hydrothermal hydrolysis unit, and aerobic fermentation unit, were chosen as the monitoring locations. The highest mean concentration of total VOC emissions was observed in the aerobic fermentation unit at 21,748.2-31,283.3 μg/m3, followed by the hydrothermal hydrolysis unit at 10,798.1-23,144.4 μg/m3. The detected VOC families included biogenic compounds (oxygenated compounds, hydrocarbons, terpenes, and organosulfur compounds) and abiogenic compounds (aromatic hydrocarbons and halocarbons). Oxygenated compounds, particularly alcohols, were the most abundant compounds in all samples. With the use of odor index analysis and principal components analysis, the hydrothermal hydrolysis and aerobic fermentation units were clearly distinguished from the pre-treatment units, as characterized by their higher contributions to odorous nuisance. Methanthiol was the dominant odorant in the hydrothermal hydrolysis unit, whereas aldehyde was the dominant odorant in the aerobic fermentation unit. Terpenes, specifically limonene, had the highest level of propylene equivalent concentration during the monitoring periods. This concentration can contribute to the increase in the atmospheric reactivity and ozone formation potential in the surrounding air. Copyright © 2015. Published by Elsevier B.V.
Reverberant acoustic energy in auditoria that comprise systems of coupled rooms
NASA Astrophysics Data System (ADS)
Summers, Jason E.
2003-11-01
A frequency-dependent model for reverberant energy in coupled rooms is developed and compared with measurements for a 1:10 scale model and for Bass Hall, Ft. Worth, TX. At high frequencies, prior statistical-acoustics models are improved by geometrical-acoustics corrections for decay within sub-rooms and for energy transfer between sub-rooms. Comparisons of computational geometrical acoustics predictions based on beam-axis tracing with scale model measurements indicate errors resulting from tail-correction assuming constant quadratic growth of reflection density. Using ray tracing in the late part corrects this error. For mid-frequencies, the models are modified to account for wave effects at coupling apertures by including power transmission coefficients. Similarly, statical-acoustics models are improved through more accurate estimates of power transmission measurements. Scale model measurements are in accord with the predicted behavior. The edge-diffraction model is adapted to study transmission through apertures. Multiple-order scattering is theoretically and experimentally shown inaccurate due to neglect of slope diffraction. At low frequencies, perturbation models qualitatively explain scale model measurements. Measurements confirm relation of coupling strength to unperturbed pressure distribution on coupling surfaces. Measurements in Bass Hall exhibit effects of the coupled stage house. High frequency predictions of statistical acoustics and geometrical acoustics models and predictions of coupling apertures all agree with measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
Volume IV contains the following attachments for Module IV: VOC monitoring plan for bin-room tests (Appendix D12); bin emission control and VOC monitoring system drawings; bin scale test room ventilation drawings; WIPP supplementary roof support system, underground storage area, room 1, panel 1, DOE/WIPP 91-057; and WIPP supplementary roof support system, room 1, panel 1, geotechnical field data analysis bi-annual report, DOE/WIPP 92-024.
Gillespie, Brigid M; Polit, Denise F; Hamlin, Lois; Chaboyer, Wendy
2012-01-01
This paper describes the development and validation of the Revised Perioperative Competence Scale (PPCS-R). There is a lack of a psychometrically tested sound self-assessment tools to measure nurses' perceived competence in the operating room. Content validity was established by a panel of international experts and the original 98-item scale was pilot tested with 345 nurses in Queensland, Australia. Following the removal of several items, a national sample that included all 3209 nurses who were members of the Australian College of Operating Room Nurses was surveyed using the 94-item version. Psychometric testing assessed content validity using exploratory factor analysis, internal consistency using Cronbach's alpha, and construct validity using the "known groups" technique. During item reduction, several preliminary factor analyses were performed on two random halves of the sample (n=550). Usable data for psychometric assessment were obtained from 1122 nurses. The original 94-item scale was reduced to 40 items. The final factor analysis using the entire sample resulted in a 40 item six-factor solution. Cronbach's alpha for the 40-item scale was .96. Construct validation demonstrated significant differences (p<.0001) in perceived competence scores relative to years of operating room experience and receipt of specialty education. On the basis of these results, the psychometric properties of the PPCS-R were considered encouraging. Further testing of the tool in different samples of operating room nurses is necessary to enable cross-cultural comparisons. Copyright © 2011 Elsevier Ltd. All rights reserved.
AUTOMOTIVE REPAIR SHOP, SLIDING DOOR LEADING TO BOILER ROOM ON ...
AUTOMOTIVE REPAIR SHOP, SLIDING DOOR LEADING TO BOILER ROOM ON SOUTH SIDE OF SOUTH WING, WITH SCALE. - Cedar City Automotive Repair Shop, Automotive Repair Shop, 820 North Main Street, Cedar City, Iron County, UT
8. INTERIOR VIEW, FIRST FLOOR, NORTHEAST ROOM, EAST WALL, ORIGINAL ...
8. INTERIOR VIEW, FIRST FLOOR, NORTHEAST ROOM, EAST WALL, ORIGINAL KITCHEN FIREPLACE AND BAKE OVEN, WITH SCALE - Edgemont, 212 Bridgetown Pike, 1/4 mile East of PA 413 (Middletown Township), Langhorne, Bucks County, PA
Interior view, room 1103, view looking from the southeast to ...
Interior view, room 1103, view looking from the southeast to fireplace and mantel and inglenook, with scale - National Park Seminary, Music Hall, Linden Lane at western edge of campus, Silver Spring, Montgomery County, MD
Smith, Casey; Qaisi, Ramy; Liu, Zhihong; Yu, Qingkai; Hussain, Muhammad Mustafa
2013-07-23
Utilization of graphene may help realize innovative low-power replacements for III-V materials based high electron mobility transistors while extending operational frequencies closer to the THz regime for superior wireless communications, imaging, and other novel applications. Device architectures explored to date suffer a fundamental performance roadblock due to lack of compatible deposition techniques for nanometer-scale dielectrics required to efficiently modulate graphene transconductance (gm) while maintaining low gate capacitance-voltage product (CgsVgs). Here we show integration of a scaled (10 nm) high-κ gate dielectric aluminum oxide (Al2O3) with an atmospheric pressure chemical vapor deposition (APCVD)-derived graphene channel composed of multiple 0.25 μm stripes to repeatedly realize room-temperature mobility of 11,000 cm(2)/V·s or higher. This high performance is attributed to the APCVD graphene growth quality, excellent interfacial properties of the gate dielectric, conductivity enhancement in the graphene stripes due to low tox/Wgraphene ratio, and scaled high-κ dielectric gate modulation of carrier density allowing full actuation of the device with only ±1 V applied bias. The superior drive current and conductance at Vdd = 1 V compared to other top-gated devices requiring undesirable seed (such as aluminum and poly vinyl alcohol)-assisted dielectric deposition, bottom gate devices requiring excessive gate voltage for actuation, or monolithic (nonstriped) channels suggest that this facile transistor structure provides critical insight toward future device design and process integration to maximize CVD-based graphene transistor performance.
Proteus DSA control room in Mojave, CA
2003-04-03
Proteus DSA control room in Mojave, CA (L to R) Jean-Pierre Soucy; Amphitech International Software engineer Craig Bomben; NASA Dryden Test Pilot Pete Siebold; (with headset, at computer controls) Scaled Composites pilot Bob Roehm; New Mexico State University (NMSU) UAV Technical Analysis Application Center (TAAC) Chuck Coleman; Scaled Composites Pilot Kari Sortland; NMSU TAAC Russell Wolfe; Modern Technology Solutions, Inc. Scaled Composites' unique tandem-wing Proteus was the testbed for a series of UAV collision-avoidance flight demonstrations. An Amphitech 35GHz radar unit installed below Proteus' nose was the primary sensor for the Detect, See and Avoid tests.
Teaching a La Cart: Music on Wheels
ERIC Educational Resources Information Center
Barrett, Joelle
2005-01-01
In this article, the author shares her experiences with teaching room-to-room or "from a cart". Depending on the building's structure, she often carried percussion instruments up and down stairs, pushed full-size pianos in and out of rooms, and transferred student books from one classroom to the next, doing what she thought was her job.Teaching…
Rooming-in Reduces Salivary Cortisol Level of Newborn
De Bernardo, Giuseppe; Riccitelli, Marina; Giordano, Maurizio; Sordino, Desiree; Longini, Mariangela
2018-01-01
Background Rooming-in practice improves breastfeeding and reduces newborn stress reactivity. When this modality is not available, partial rooming-in after birth can be considered. Salivary cortisol levels (SCLs) are considered reliable biomarkers to indicate stress. Objective To test the hypothesis that rooming-in duration impacts neonatal stress response in hospitalized newborns. Design/methods Forty term newborns, enrolled in the Neonatology and Obstetrics Nursing, C.G. Ruesch, Naples, Italy, were divided, according to the mother's choice, into the study (SG; n = 20) and control (CG; n = 20) groups if they received full (24 hs) or partial (14 hs) rooming-in care, respectively. Saliva samples were collected from all babies between 7:00 a.m. and 8:00 a.m. of the 3rd day of life by using oral swab. Salivary cortisol levels were measured using an enzyme immunoassay kit (Salimetrics LLC, PA, USA). Results A statistically significant difference in the SCLs between SG and CG was found (median: 258 ng/dl versus 488.5 ng/dl; p = 0.048). Conclusions Data support the practice of full rooming-in care compared with partial rooming-in. The rooming-in duration clearly reduces SCLs and likely neonatal stress. These lower SCLs may have long-term positive effects reducing the risk of metabolic syndrome, high blood pressure, and cognitive and behavioural changes. PMID:29706798
Jeong, Chang-Won; Ryu, Jong-Hyun; Joo, Su-Chong; Jun, Hong-Young; Heo, Dong-Woon; Lee, Jinseok; Kim, Kyong-Woo; Yoon, Kwon-Ha
2015-01-01
Technologies employing digital X-ray devices are developed for mobile settings. To develop a mobile digital X-ray fluoroscopy (MDF) for intraoperative guidance, using a novel flat panel detector to focus on diagnostics in outpatient clinics, operating and emergency rooms. An MDF for small-scale field diagnostics was configured using an X-ray source and a novel flat panel detector. The imager enabled frame rates reaching 30 fps in full resolution fluoroscopy with maximal running time of 5 minutes. Signal-to-noise (SNR), contrast-to-noise (CNR), and spatial resolution were analyzed. Stray radiation, exposure radiation dose, and effective absorption dose were measured for patients. The system was suitable for small-scale field diagnostics. SNR and CNR were 62.4 and 72.0. Performance at 10% of MTF was 9.6 lp/mm (53 μ m) in the no binned mode. Stray radiation at 100 cm and 150 cm from the source was below 0.2 μ Gy and 0.1 μ Gy. Exposure radiation in radiography and fluoroscopy (5 min) was 10.2 μ Gy and 82.6 mGy. The effective doses during 5-min-long fluoroscopy were 0.26 mSv (wrist), 0.28 mSv (elbow), 0.29 mSv (ankle), and 0.31 mSv (knee). The proposed MDF is suitable for imaging in operating rooms.
Detail of lockers, shelving, etc. in art rooms and supply ...
Detail of lockers, shelving, etc. in art rooms and supply room. San Bernardino Valley Union Junior College, Classics Building. Lockers, bins, and cupboards-plans, elevations, sections. Howard E. Jones, Architect, San Bernardino, California. Sheet 7, job no. 312. Scale 1/2 inch to the foot. February 15, 1927. - San Bernardino Valley College, Classics Building, 701 South Mount Vernon Avenue, San Bernardino, San Bernardino County, CA
Autonomous calibration of single spin qubit operations
NASA Astrophysics Data System (ADS)
Frank, Florian; Unden, Thomas; Zoller, Jonathan; Said, Ressa S.; Calarco, Tommaso; Montangero, Simone; Naydenov, Boris; Jelezko, Fedor
2017-12-01
Fully autonomous precise control of qubits is crucial for quantum information processing, quantum communication, and quantum sensing applications. It requires minimal human intervention on the ability to model, to predict, and to anticipate the quantum dynamics, as well as to precisely control and calibrate single qubit operations. Here, we demonstrate single qubit autonomous calibrations via closed-loop optimisations of electron spin quantum operations in diamond. The operations are examined by quantum state and process tomographic measurements at room temperature, and their performances against systematic errors are iteratively rectified by an optimal pulse engineering algorithm. We achieve an autonomous calibrated fidelity up to 1.00 on a time scale of minutes for a spin population inversion and up to 0.98 on a time scale of hours for a single qubit π/2 -rotation within the experimental error of 2%. These results manifest a full potential for versatile quantum technologies.
40 CFR 62.15105 - Who must complete the operator training course? By when?
Code of Federal Regulations, 2011 CFR
2011-07-01
... supervisors, and control room operators who have obtained full certification from the American Society of... supervisors, and control room operators who have obtained provisional certification from the American Society...
40 CFR 62.15105 - Who must complete the operator training course? By when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... supervisors, and control room operators who have obtained full certification from the American Society of... supervisors, and control room operators who have obtained provisional certification from the American Society...
13. FRIST FLOOR, SOUTHEAST ROOM, SOUTHWEST WALL, HEARTH WITH KETTLES ...
13. FRIST FLOOR, SOUTHEAST ROOM, SOUTHWEST WALL, HEARTH WITH KETTLES USED FOR RENDERING LARD (LEFT) AND MAKING APPLE BUTTER (RIGHT) WITH SCALE - Open Gate Farm, House, Ridge Road, 1 mile East of Elephant Road, Perkasie, Bucks County, PA
19. Southeast end room; view to southeast, 65mm lens plus ...
19. Southeast end room; view to southeast, 65mm lens plus electronic flash illumination. Note extent of failure; figure for scale. - Benicia Arsenal, Powder Magazine No. 5, Junction of Interstate Highways 680 & 780, Benicia, Solano County, CA
Simulating wall and corner fire tests on wood products with the OSU room fire model
H. C. Tran
1994-01-01
This work demonstrates the complexity of modeling wall and corner fires in a compartment. The model chosen for this purpose is the Ohio State University (OSU) room fire model. This model was designed to simulate fire growth on walls in a compartment and therefore lends itself to direct comparison with standard room test results. The model input were bench-scale data...
Microbes in the neonatal intensive care unit resemble those found in the gut of premature infants
2014-01-01
Background The source inoculum of gastrointestinal tract (GIT) microbes is largely influenced by delivery mode in full-term infants, but these influences may be decoupled in very low birth weight (VLBW, <1,500 g) neonates via conventional broad-spectrum antibiotic treatment. We hypothesize the built environment (BE), specifically room surfaces frequently touched by humans, is a predominant source of colonizing microbes in the gut of premature VLBW infants. Here, we present the first matched fecal-BE time series analysis of two preterm VLBW neonates housed in a neonatal intensive care unit (NICU) over the first month of life. Results Fresh fecal samples were collected every 3 days and metagenomes sequenced on an Illumina HiSeq2000 device. For each fecal sample, approximately 33 swabs were collected from each NICU room from 6 specified areas: sink, feeding and intubation tubing, hands of healthcare providers and parents, general surfaces, and nurse station electronics (keyboard, mouse, and cell phone). Swabs were processed using a recently developed ‘expectation maximization iterative reconstruction of genes from the environment’ (EMIRGE) amplicon pipeline in which full-length 16S rRNA amplicons were sheared and sequenced using an Illumina platform, and short reads reassembled into full-length genes. Over 24,000 full-length 16S rRNA sequences were produced, generating an average of approximately 12,000 operational taxonomic units (OTUs) (clustered at 97% nucleotide identity) per room-infant pair. Dominant gut taxa, including Staphylococcus epidermidis, Klebsiella pneumoniae, Bacteroides fragilis, and Escherichia coli, were widely distributed throughout the room environment with many gut colonizers detected in more than half of samples. Reconstructed genomes from infant gut colonizers revealed a suite of genes that confer resistance to antibiotics (for example, tetracycline, fluoroquinolone, and aminoglycoside) and sterilizing agents, which likely offer a competitive advantage in the NICU environment. Conclusions We have developed a high-throughput culture-independent approach that integrates room surveys based on full-length 16S rRNA gene sequences with metagenomic analysis of fecal samples collected from infants in the room. The approach enabled identification of discrete ICU reservoirs of microbes that also colonized the infant gut and provided evidence for the presence of certain organisms in the room prior to their detection in the gut. PMID:24468033
Wang, Rongmei; Shi, Nianke; Bai, Jinbing; Zheng, Yaguang; Zhao, Yue
2015-07-09
The present study was designed to implement an interprofessional simulation-based education program for nursing students and evaluate the influence of this program on nursing students' attitudes toward interprofessional education and knowledge about operating room nursing. Nursing students were randomly assigned to either the interprofessional simulation-based education or traditional course group. A before-and-after study of nursing students' attitudes toward the program was conducted using the Readiness for Interprofessional Learning Scale. Responses to an open-ended question were categorized using thematic content analysis. Nursing students' knowledge about operating room nursing was measured. Nursing students from the interprofessional simulation-based education group showed statistically different responses to four of the nineteen questions in the Readiness for Interprofessional Learning Scale, reflecting a more positive attitude toward interprofessional learning. This was also supported by thematic content analysis of the open-ended responses. Furthermore, nursing students in the simulation-based education group had a significant improvement in knowledge about operating room nursing. The integrated course with interprofessional education and simulation provided a positive impact on undergraduate nursing students' perceptions toward interprofessional learning and knowledge about operating room nursing. Our study demonstrated that this course may be a valuable elective option for undergraduate nursing students in operating room nursing education.
Sheu, R J; Sheu, R D; Jiang, S H; Kao, C H
2005-01-01
Full-scale Monte Carlo simulations of the cyclotron room of the Buddhist Tzu Chi General Hospital were carried out to improve the original inadequate maze design. Variance reduction techniques are indispensable in this study to facilitate the simulations for testing a variety of configurations of shielding modification. The TORT/MCNP manual coupling approach based on the Consistent Adjoint Driven Importance Sampling (CADIS) methodology has been used throughout this study. The CADIS utilises the source and transport biasing in a consistent manner. With this method, the computational efficiency was increased significantly by more than two orders of magnitude and the statistical convergence was also improved compared to the unbiased Monte Carlo run. This paper describes the shielding problem encountered, the procedure for coupling the TORT and MCNP codes to accelerate the calculations and the calculation results for the original and improved shielding designs. In order to verify the calculation results and seek additional accelerations, sensitivity studies on the space-dependent and energy-dependent parameters were also conducted.
Lap Shear Testing of Candidate Radiator Panel Adhesives
NASA Technical Reports Server (NTRS)
Ellis, David; Briggs, Maxwell; McGowan, Randy
2013-01-01
During testing of a subscale radiator section used to develop manufacturing techniques for a full-scale radiator panel, the adhesive bonds between the titanium heat pipes and the aluminum face sheets failed during installation and operation. Analysis revealed that the thermal expansion mismatch between the two metals resulted in relatively large shear stresses being developed even when operating the radiator at moderate temperatures. Lap shear testing of the adhesive used in the original joints demonstrated that the two-part epoxy adhesive fell far short of the strength required. A literature review resulted in several candidate adhesives being selected for lap shear joint testing at room temperature and 398 K, the nominal radiator operating temperature. The results showed that two-part epoxies cured at room and elevated temperatures generally did not perform well. Epoxy film adhesives cured at elevated temperatures, on the other hand, did very well with most being sufficiently strong to cause yielding in the titanium sheet used for the joints. The use of an epoxy primer generally improved the strength of the joint. Based upon these results, a new adhesive was selected for the second subscale radiator section.
NASA Astrophysics Data System (ADS)
Jankó, A.; Bánfi, R.
2009-04-01
The Royal Hungarian State Mapping Institute kept the smaller scales series of the third military survey of the Austro-Hungarian Monarchy, too, so the scales 1:200,000 and 1:750,000 maps. The results of the supervisions of larger scales were transferred onto these scales, 1:200,000 and 1:750,000 maps, for the territory of Central Europe. In 1943 a scale 1:500,000 aerial map was accomplished, too, for the territory of Pannonian basin. There are many other important series in the Map Room between 1919 and 1945, including the WWII German edition 1:300,000 scale map series of Central Europe and Russia to the Ural Mts.; and a series of scale 1:100,000 for the territory of Poland and Russia between 1939-1940.
A Tabletop Tool for Modeling Life Support Systems
NASA Technical Reports Server (NTRS)
Ramachandran, N.; Majumdar, A.; McDaniels, D.; Stewart, E.
2003-01-01
This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations.
Dolberg, Ornah T; Barkai, Gabriel; Leor, Agnes; Rapoport, Helena; Bloch, Miki; Schreiber, Shaul
2010-03-01
To assess the short- (3-9 months) and medium-term (30 months) occurrence and severity of post-traumatic stress disorder (PTSD) in civilian survivors of suicide bombing terrorist attacks. We evaluated 129 injured survivors of nine attacks in Israel who were treated in our emergency room between June 2000 and September 2002. Data on demographics, physical injuries and psychiatric symptoms were collected by both a structured clinical interview and standard assessment scales for depression, anxiety, and sleep quality. Diagnosis of PTSD was based on a Hebrew-validated DSM-IV SCID-PTSD rating scale. At the first assessment (short-term), 20 survivors (15.5%) met the criteria for full-blown PTSD and 54 (42%) for sub-clinical PTSD, while 55 (42.5%) evidenced no symptoms of PTSD. Two years later, only 54 patients could be located: 19 (35%) of them had either persistent or de novo PTSD and none had residual sub-clinical PTSD. Relatively few survivors of suicide bomb attacks had full-blown PTSD, while a substantial number of survivors had short-term sub-clinical PTSD. Two-year follow-up evaluations revealed that a significant a number of the patients available for testing (35%) had full-blown PTSD. These findings imply that medium-term follow-up of survivors is needed in order to establish the actual prevalence of PTSD.
Data for Room Fire Model Comparisons
Peacock, Richard D.; Davis, Sanford; Babrauskas, Vytenis
1991-01-01
With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system. PMID:28184121
Data for Room Fire Model Comparisons.
Peacock, Richard D; Davis, Sanford; Babrauskas, Vytenis
1991-01-01
With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system.
NASA Astrophysics Data System (ADS)
Mourid, Amina; El Alami, Mustapha
2018-05-01
In this paper, we present a comparative thermal study of the usual insulation materials used in the building as well as the innovate one like phase change materials (PCMs). Both experimental study and numerical approach were applied in this work for summer season. In the experimental study the PCM was installed on the outer surface on the ceiling of one of two full-scale rooms located at FSAC, Casablanca. A simulation model was performed with TRNSYS’17 software. We have established as a criterion of comparison the internal temperatures. An economic study also has been carried out. Based on this latter, that the PCM is most efficient.
NASA Technical Reports Server (NTRS)
Holanda, R.; Frause, L. M.
1977-01-01
The reliability of 45 state-of-the-art strain gage systems under full scale engine testing was investigated. The flame spray process was used to install 23 systems on the first fan rotor of a YF-100 engine; the others were epoxy cemented. A total of 56 percent of the systems failed in 11 hours of engine operation. Flame spray system failures were primarily due to high gage resistance, probably caused by high stress levels. Epoxy system failures were principally erosion failures, but only on the concave side of the blade. Lead-wire failures between the blade-to-disk jump and the control room could not be analyzed.
5. Credit BG. This interior view shows the weigh room, ...
5. Credit BG. This interior view shows the weigh room, looking west (240°): Electric lighting and scale read-outs (boxes with circular windows on the wall) are fitted with explosion-proof enclosures; these enclosures prevent malfunctioning electrical parts from sparking and starting fires or explosions. One marble table and scale have been removed at the extreme left of the view. Two remaining scales handle small and large quantities of propellants and additives. Marble tables do not absorb chemicals or conduct electricity; their mass also prevents vibration from upsetting the scales. The floor has an electrically conductive coating to dissipate static electric charges, thus preventing sparks which might ignite propellants. - Jet Propulsion Laboratory Edwards Facility, Weigh & Control Building, Edwards Air Force Base, Boron, Kern County, CA
Scalable room-temperature conversion of copper(II) hydroxide into HKUST-1 (Cu3 (btc)2).
Majano, Gerardo; Pérez-Ramírez, Javier
2013-02-20
Copper(II) hydroxide is converted directly to HKUST-1 (Cu(3) (btc)(2) ) after only 5 min at room-temperature in aqueous ethanolic solution without the need of additional solvents. Scale up to the kilogram scale does not influence porous properties yielding pure-phase product with a remarkable total surface area exceeding 1700 m(2) g(-1) featuring aggregates of nanometer-sized crystals (<600 nm) and extremely high space-time yields. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ali, Muhammad; Oshiki, Mamoru; Okabe, Satoshi
2014-06-15
It is still the biggest challenge to secure enough seeding biomass for rapid start-up of full-scale (anaerobic ammonium oxidation) anammox processes due to slow growth. Preservation of active anammox biomass could be one of the solutions. In this study, biomass of anammox bacterium, "Candidatus Brocadia sinica", immersed in various nutrient media were preserved at -80 °C, 4 °C and room temperature. After 45, 90 and 150 days of preservation, specific anammox activity (SAA) of the preserved anammox biomass was determined by measuring (29)N2 production rate and transcription levels of hzsA gene encoding hydrazine synthase alpha subunit. Storage in nutrient medium containing 3 mM of molybdate at room temperature with periodical (every 45 days) supply of NH4(+) and NO2(-) was proved to be the most effective storage technique for "Ca. Brocadia sinica" biomass. Using this preservation condition, 96, 92 and 65% of the initial SAA was sustained after 45, 90 and 150 days of storage, respectively. Transcription levels of hzsA gene in biomass correlated with the SAA (R(2) = 0.83), indicating it can be used as a genetic marker to evaluate the anammox activity of preserved biomass. Furthermore, the 90-day-stored biomass was successfully reactivated by immobilizing in polyvinyl alcohol (6%, w/v) and sodium alginate (2%, w/v) gel and then inoculated to up-flow column reactors. Total nitrogen removal rates rapidly increased to 7 kg-N m(-3) d(-1) within 35 days of operation. Based on these results, the room temperature preservation with molybdate addition is simple, cost-effective and feasible at a practical scale, which will accelerate the practical use of anammox process for wastewater treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Kemp, Wayne
This publication describes options for designing and equipping middle and high school music education suites and suggests means of gaining community support for including full service music suites in new and renovated facilities. It covers the basic music suite, practice rooms, small ensemble rehearsal rooms, recording/MIDI (musical instrument…
Langergraber, Guenter; Pressl, Alexander; Haberl, Raimund
2014-01-01
This paper describes the results of the first full-scale implementation of a two-stage vertical flow constructed wetland (CW) system developed to increase nitrogen removal. The full-scale system was constructed for the Bärenkogelhaus, which is located in Styria at the top of a mountain, 1,168 m above sea level. The Bärenkogelhaus has a restaurant with 70 seats, 16 rooms for overnight guests and is a popular site for day visits, especially during weekends and public holidays. The CW treatment system was designed for a hydraulic load of 2,500 L.d(-1) with a specific surface area requirement of 2.7 m(2) per person equivalent (PE). It was built in fall 2009 and started operation in April 2010 when the restaurant was re-opened. Samples were taken between July 2010 and June 2013 and were analysed in the laboratory of the Institute of Sanitary Engineering at BOKU University using standard methods. During 2010 the restaurant at Bärenkogelhaus was open 5 days a week whereas from 2011 the Bärenkogelhaus was open only on demand for events. This resulted in decreased organic loads of the system in the later period. In general, the measured effluent concentrations were low and the removal efficiencies high. During the whole period the ammonia nitrogen effluent concentration was below 1 mg/L even at effluent water temperatures below 3 °C. Investigations during high-load periods, i.e. events like weddings and festivals at weekends, with more than 100 visitors, showed a very robust treatment performance of the two-stage CW system. Effluent concentrations of chemical oxygen demand and NH4-N were not affected by these events with high hydraulic loads.
Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, Casey Robert; Rice, Brandon Charles; Bower, Gordon Ross
Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.
Graphene-based room-temperature implementation of a modified Deutsch-Jozsa quantum algorithm.
Dragoman, Daniela; Dragoman, Mircea
2015-12-04
We present an implementation of a one-qubit and two-qubit modified Deutsch-Jozsa quantum algorithm based on graphene ballistic devices working at room temperature. The modified Deutsch-Jozsa algorithm decides whether a function, equivalent to the effect of an energy potential distribution on the wave function of ballistic charge carriers, is constant or not, without measuring the output wave function. The function need not be Boolean. Simulations confirm that the algorithm works properly, opening the way toward quantum computing at room temperature based on the same clean-room technologies as those used for fabrication of very-large-scale integrated circuits.
Mao, Yiyin; shi, Li; Huang, Hubiao; Cao, Wei; Li, Junwei; Sun, Luwei; Jin, Xianda; Peng, Xinsheng
2013-06-25
Large scale, robust, well intergrown free-standing HKUST-1 membranes were converted from copper hydroxide nanostrand free-standing films in 1,3,5-benzenetricarboxylic acid water-ethanol solution at room temperature, and explored for gas separation. The truncated crystals are controllable and favorable for the dense intergrowth.
Length scale selects directionality of droplets on vibrating pillar ratchet
Agapov, Rebecca L.; Boreyko, Jonathan B.; Briggs, Dayrl P.; ...
2014-09-22
Directional control of droplet motion at room temperature is of interest for applications such as microfluidic devices, self-cleaning coatings, and directional adhesives. Here, arrays of tilted pillars ranging in height from the nanoscale to the microscale are used as structural ratchets to directionally transport water at room temperature. Water droplets deposited on vibrating chips with a nanostructured ratchet move preferentially in the direction of the feature tilt while the opposite directionality is observed in the case of microstructured ratchets. This remarkable switch in directionality is consistent with changes in the contact angle hysteresis. To glean further insights into the lengthmore » scale dependent asymmetric contact angle hysteresis, the contact lines formed by a nonvolatile room temperature ionic liquid placed onto the tilted pillar arrays were visualized and analyzed in situ in a scanning electron microscope. As a result, the ability to tune droplet directionality by merely changing the length scale of surface features all etched at the same tilt angle would be a versatile tool for manipulating multiphase flows and for selecting droplet directionality in other lap-on-chip applications.« less
Spilak, Michal P.; Sigsgaard, Torben; Takai, Hisamitsu; Zhang, Guoqiang
2016-01-01
People spend approximately one third of their life sleeping. Exposure to pollutants in the sleep environment often leads to a variety of adverse health effects, such as development and exacerbation of asthma. Avoiding exposure to these pollutants by providing a sufficient air quality in the sleep environment might be a feasible method to alleviate these health symptoms. We performed full-scale laboratory measurements using a thermal manikin positioned on an experimental bed. Three ventilation settings were tested: with no filtration system operated, use of portable air cleaner and use of a temperature-controlled laminar airflow (TLA) device. The first part of the experiment investigated the air-flow characteristics in the breathing zone. In the second part, particle removal efficiency was estimated. Measured in the breathing zone, the room air cleaner demonstrated high turbulence intensity, high velocity and turbulence diffusivity level, with a particle reduction rate of 52% compared to baseline after 30 minutes. The TLA device delivered a laminar airflow to the breathing zone with a reduction rate of 99.5%. During a periodical duvet lifting mimicking a subject’s movement in bed, the particle concentration was significantly lower with the TLA device compared to the room air cleaner. The TLA device provided a barrier which significantly reduced the introduction of airborne particles into the breathing zone. Further studies should be conducted for the understanding of the transport of resuspended particles between the duvet and the laying body. PMID:27898693
Spilak, Michal P; Sigsgaard, Torben; Takai, Hisamitsu; Zhang, Guoqiang
2016-01-01
People spend approximately one third of their life sleeping. Exposure to pollutants in the sleep environment often leads to a variety of adverse health effects, such as development and exacerbation of asthma. Avoiding exposure to these pollutants by providing a sufficient air quality in the sleep environment might be a feasible method to alleviate these health symptoms. We performed full-scale laboratory measurements using a thermal manikin positioned on an experimental bed. Three ventilation settings were tested: with no filtration system operated, use of portable air cleaner and use of a temperature-controlled laminar airflow (TLA) device. The first part of the experiment investigated the air-flow characteristics in the breathing zone. In the second part, particle removal efficiency was estimated. Measured in the breathing zone, the room air cleaner demonstrated high turbulence intensity, high velocity and turbulence diffusivity level, with a particle reduction rate of 52% compared to baseline after 30 minutes. The TLA device delivered a laminar airflow to the breathing zone with a reduction rate of 99.5%. During a periodical duvet lifting mimicking a subject's movement in bed, the particle concentration was significantly lower with the TLA device compared to the room air cleaner. The TLA device provided a barrier which significantly reduced the introduction of airborne particles into the breathing zone. Further studies should be conducted for the understanding of the transport of resuspended particles between the duvet and the laying body.
NASA Astrophysics Data System (ADS)
Allcorn, Eric; Nagasubramanian, Ganesan; Pratt, Harry D.; Spoerke, Erik; Ingersoll, David
2018-02-01
Flow batteries are an attractive technology for energy storage of grid-scale renewables. However, performance issues related to ion-exchange membrane (IEM) fouling and crossover of species have limited the success of flow batteries. In this work we propose the use of the solid-state sodium-ion conductor NaSICON as an IEM to fully eliminate active species crossover in room temperature, aqueous, neutral pH flow batteries. We measure the room temperature conductivity of NaSICON at 2.83-4.67 mS cm-1 and demonstrate stability of NaSICON in an aqueous electrolyte with conductivity values remaining near 2.5 mS cm-1 after 66 days of exposure. Charge and discharge of a full H-cell battery as well as symmetric cycling in a flow battery configuration using NaSICON as an IEM in both cases demonstrates the capability of the solid-state IEM. Extensive analysis of aged cells through electrochemical impedance spectroscopy (EIS) and UV-vis spectroscopy show no contaminant species having crossed over the NaSICON membrane after 83 days of exposure, yielding an upper limit to the permeability of NaSICON of 4 × 10-10 cm2 min-1. The demonstration of NaSICON as an IEM enables a wide new range of chemistries for application to flow batteries that would previously be impeded by species crossover and associated degradation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allcorn, Eric; Nagasubramanian, Ganesan; Pratt, III, Harry D.
Flow batteries are an attractive technology for energy storage of grid-scale renewables. However, performance issues related to ion-exchange membrane (IEM) fouling and crossover of species have limited the success of flow batteries. In this work we propose the use of the solid-state sodium-ion conductor NaSICON as an IEM to fully eliminate active species crossover in room temperature, aqueous, neutral pH flow batteries. We measure the room temperature conductivity of NaSICON at 2.83–4.67 mS cm –1 and demonstrate stability of NaSICON in an aqueous electrolyte with conductivity values remaining near 2.5 mS cm –1 after 66 days of exposure. Charge andmore » discharge of a full H-cell battery as well as symmetric cycling in a flow battery configuration using NaSICON as an IEM in both cases demonstrates the capability of the solid-state IEM. Extensive analysis of aged cells through electrochemical impedance spectroscopy (EIS) and UV–vis spectroscopy show no contaminant species having crossed over the NaSICON membrane after 83 days of exposure, yielding an upper limit to the permeability of NaSICON of 4 × 10 –10 cm 2 min –1. As a result, the demonstration of NaSICON as an IEM enables a wide new range of chemistries for application to flow batteries that would previously be impeded by species crossover and associated degradation.« less
Allcorn, Eric; Nagasubramanian, Ganesan; Pratt, III, Harry D.; ...
2018-01-04
Flow batteries are an attractive technology for energy storage of grid-scale renewables. However, performance issues related to ion-exchange membrane (IEM) fouling and crossover of species have limited the success of flow batteries. In this work we propose the use of the solid-state sodium-ion conductor NaSICON as an IEM to fully eliminate active species crossover in room temperature, aqueous, neutral pH flow batteries. We measure the room temperature conductivity of NaSICON at 2.83–4.67 mS cm –1 and demonstrate stability of NaSICON in an aqueous electrolyte with conductivity values remaining near 2.5 mS cm –1 after 66 days of exposure. Charge andmore » discharge of a full H-cell battery as well as symmetric cycling in a flow battery configuration using NaSICON as an IEM in both cases demonstrates the capability of the solid-state IEM. Extensive analysis of aged cells through electrochemical impedance spectroscopy (EIS) and UV–vis spectroscopy show no contaminant species having crossed over the NaSICON membrane after 83 days of exposure, yielding an upper limit to the permeability of NaSICON of 4 × 10 –10 cm 2 min –1. As a result, the demonstration of NaSICON as an IEM enables a wide new range of chemistries for application to flow batteries that would previously be impeded by species crossover and associated degradation.« less
Fabrication of All-SiC Fiber-Optic Pressure Sensors for High-Temperature Applications
Jiang, Yonggang; Li, Jian; Zhou, Zhiwen; Jiang, Xinggang; Zhang, Deyuan
2016-01-01
Single-crystal silicon carbide (SiC)-based pressure sensors can be used in harsh environments, as they exhibit stable mechanical and electrical properties at elevated temperatures. A fiber-optic pressure sensor with an all-SiC sensor head was fabricated and is herein proposed. SiC sensor diaphragms were fabricated via an ultrasonic vibration mill-grinding (UVMG) method, which resulted in a small grinding force and low surface roughness. The sensor head was formed by hermetically bonding two layers of SiC using a nickel diffusion bonding method. The pressure sensor illustrated a good linearity in the range of 0.1–0.9 MPa, with a resolution of 0.27% F.S. (full scale) at room temperature. PMID:27763494
Fabrication of All-SiC Fiber-Optic Pressure Sensors for High-Temperature Applications.
Jiang, Yonggang; Li, Jian; Zhou, Zhiwen; Jiang, Xinggang; Zhang, Deyuan
2016-10-17
Single-crystal silicon carbide (SiC)-based pressure sensors can be used in harsh environments, as they exhibit stable mechanical and electrical properties at elevated temperatures. A fiber-optic pressure sensor with an all-SiC sensor head was fabricated and is herein proposed. SiC sensor diaphragms were fabricated via an ultrasonic vibration mill-grinding (UVMG) method, which resulted in a small grinding force and low surface roughness. The sensor head was formed by hermetically bonding two layers of SiC using a nickel diffusion bonding method. The pressure sensor illustrated a good linearity in the range of 0.1-0.9 MPa, with a resolution of 0.27% F.S. (full scale) at room temperature.
The Effect of Furnishing on Perceived Spatial Dimensions and Spaciousness of Interior Space
von Castell, Christoph; Oberfeld, Daniel; Hecht, Heiko
2014-01-01
Despite the ubiquity of interior space design, there is virtually no scientific research on the influence of furnishing on the perception of interior space. We conducted two experiments in which observers were asked to estimate the spatial dimensions (size of the room dimensions in meters and centimeters) and to judge subjective spaciousness of various rooms. Experiment 1 used true-to-scale model rooms with a square surface area. Furnishing affected both the perceived height and the spaciousness judgments. The furnished room was perceived as higher but less spacious. In Experiment 2, rooms with different square surface areas and constant physical height were presented in virtual reality. Furnishing affected neither the perceived spatial dimensions nor the perceived spaciousness. Possible reasons for this discrepancy, such as the influence of the presentation medium, are discussed. Moreover, our results suggest a compression of perceived height and depth with decreasing surface area of the room. PMID:25409456
The effect of furnishing on perceived spatial dimensions and spaciousness of interior space.
von Castell, Christoph; Oberfeld, Daniel; Hecht, Heiko
2014-01-01
Despite the ubiquity of interior space design, there is virtually no scientific research on the influence of furnishing on the perception of interior space. We conducted two experiments in which observers were asked to estimate the spatial dimensions (size of the room dimensions in meters and centimeters) and to judge subjective spaciousness of various rooms. Experiment 1 used true-to-scale model rooms with a square surface area. Furnishing affected both the perceived height and the spaciousness judgments. The furnished room was perceived as higher but less spacious. In Experiment 2, rooms with different square surface areas and constant physical height were presented in virtual reality. Furnishing affected neither the perceived spatial dimensions nor the perceived spaciousness. Possible reasons for this discrepancy, such as the influence of the presentation medium, are discussed. Moreover, our results suggest a compression of perceived height and depth with decreasing surface area of the room.
Purwar, B; Ismail, K M; Turner, N; Farrell, A; Verzune, M; Annappa, M; Smith, I; El-Gizawy, Zeiad; Cooper, J C
2015-08-01
Spinal anaesthesia (SA) and general anaesthesia (GA) are widely used techniques for vaginal surgery for pelvic floor disorders with inconclusive evidence of the superiority of either. We conducted a randomised controlled trial (RCT) to assess the feasibility of a full scale RCT aiming to examine the effect of anaesthetic mode for vaginal surgery on operative, patient reported and length of hospital stay (LOHS) outcomes. Patients undergoing vaginal surgery, recruited through a urogynaecology service in a University teaching hospital, were randomised to receive either GA or SA. Patients were followed up for 12 weeks postoperatively. Pain was measured on a visual analogue scale; nausea was assessed with a four-point verbal rating scale. Patient's subjective perception of treatment outcome, quality of life (QoL) and functional outcomes were assessed using the International Consultation on Incontinence Modular Questionnaire (ICIQ) on vaginal symptoms and the SF-36 questionnaire. Sixty women were randomised, 29 to GA and 31 to SA. The groups were similar in terms of age and type of vaginal surgery performed. No statistically significant differences were noted between the groups with regard to pain, nausea, quality of life (QoL), functional outcomes as well as length of stay in the postoperative recovery room, use of analgesia postoperatively and LOHS. This study has demonstrated that a full RCT is feasible and should focus on the length of hospital stay in a subgroup of patients undergoing vaginal surgery where SA may help to facilitate enhanced recovery or day surgery.
Fabrication and Characteristics of an nc-Si/c-Si Heterojunction MOSFETs Pressure Sensor
Zhao, Xiaofeng; Wen, Dianzhong; Li, Gang
2012-01-01
A novel nc-Si/c-Si heterojunction MOSFETs pressure sensor is proposed in this paper, with four p-MOSFETs with nc-Si/c-Si heterojunction as source and drain. The four p-MOSFETs are designed and fabricated on a square silicon membrane by CMOS process and MEMS technology where channel resistances of the four nc-Si/c-Si heterojunction MOSFETs form a Wheatstone bridge. When the additional pressure is P, the nc-Si/c-Si heterojunction MOSFETs pressure sensor can measure this additional pressure P. The experimental results show that when the supply voltage is 3 V, length-width (L:W) ratio is 2:1, and the silicon membrane thickness is 75 μm, the full scale output voltage of the pressure sensor is 15.50 mV at room temperature, and pressure sensitivity is 0.097 mV/kPa. When the supply voltage and L:W ratio are the same as the above, and the silicon membrane thickness is 45 μm, the full scale output voltage is 43.05 mV, and pressure sensitivity is 2.153 mV/kPa. Therefore, the sensor has higher sensitivity and good temperature characteristics compared to the traditional piezoresistive pressure sensor. PMID:22778646
The Interaction of Focused Attention with Flow-field Sensitivity
NASA Technical Reports Server (NTRS)
Stoffregen, T.
1984-01-01
Two studies were performed to determine whether a subject's response to naturalistic optical flow specifying egomotion would be affected by a concurrent attention task. In the first study subjects stood in a moving room in which various areas of the optical flow generated by room movement were visible. Subjects responded to room motion with strong compensatory sway when the entire room was visible. When the side walls of the room were completely obscured by stationary screens, leaving only the front wall visible, sway was significantly reduced, though it remained greater than in an eyes-closed control. In Exp. 2 subjects were presented with either the full room (large sway response) or the room with only the front wall visible (moderate response), each in combination with either a hard or easy verbal addition task. Preliminary results show that swaying in the fully visible room and in the room with only the front wall visible increased when combined with either the hard or easy tasks. These preliminary results suggest that at the least the pick-up of optical flow specifying egomotion is not affected by concurrent attentional activity.
Perceptually relevant parameters for virtual listening simulation of small room acoustics
Zahorik, Pavel
2009-01-01
Various physical aspects of room-acoustic simulation techniques have been extensively studied and refined, yet the perceptual attributes of the simulations have received relatively little attention. Here a method of evaluating the perceptual similarity between rooms is described and tested using 15 small-room simulations based on binaural room impulse responses (BRIRs) either measured from a real room or estimated using simple geometrical acoustic modeling techniques. Room size and surface absorption properties were varied, along with aspects of the virtual simulation including the use of individualized head-related transfer function (HRTF) measurements for spatial rendering. Although differences between BRIRs were evident in a variety of physical parameters, a multidimensional scaling analysis revealed that when at-the-ear signal levels were held constant, the rooms differed along just two perceptual dimensions: one related to reverberation time (T60) and one related to interaural coherence (IACC). Modeled rooms were found to differ from measured rooms in this perceptual space, but the differences were relatively small and should be easily correctable through adjustment of T60 and IACC in the model outputs. Results further suggest that spatial rendering using individualized HRTFs offers little benefit over nonindividualized HRTF rendering for room simulation applications where source direction is fixed. PMID:19640043
Natural convection flows and associated heat transfer processes in room fires
NASA Astrophysics Data System (ADS)
Sargent, William Stapf
This report presents the results of experimental investigations of natural convection flows and associated heat transfer processes produced by small fires in rooms with a single door or window opening. Calculation procedures have been developed to model the major aspects of these flows.Two distinct sets of experiments were undertaken.First, in a roughly 1/4 scale facility, a slightly dense solution of brine was allowed to flow into a tank of fresh water. The resulting density difference produced a flow which simulated a very small fire in a room with adiabatic walls. Second, in an approximately 1/2 scale test room, a nearly stoichioinetric mixture of air and natural gas was burned at floor level to model moderate strength fires. In this latter facility, we directly measured the heat conducted through the walls, in addition to determining the gas temperature and composition throughout the room.These two facilities complemented each other. The former offered good flow visualization and allowed us to observe the basic flow phenomena in the absence of heat transfer effects. On the other hand, the latter, which involved relatively larger fires, was a more realistic simulation of an actual room fire, and allowed us to calculate the convective heat transfer to the ceiling and walls. In addition, the stronger sources present in these 1/2 scale tests produced significant secondary flows. These secondary flows along with heat transfer effects act to modify the gas temperature or density profiles within the room from those observed in the 1/4 scale experiments.Several calculation procedures have been developed, based on the far field properties of plumes when the density differences are small (the Boussinesq approximation). The simple point source plume solution is used along with hydraulic analysis of flow through an orifice to estimate the temperatures of the hot ceiling layer gas and of the cooler floor zone fluid, as well as the height of the interface between them. A finite source plume model is combined with conservation equations across the interface to compute the evolution of the plume above the interface. This calculation then provides the starting point for an integral analysis of the flow and heat transfer in the turbulent ceiling jet.The computed results both for the average floor and ceiling zone gas temperatures, and for the connective heat transfer in the ceiling jet agreed reasonably well with our experimental data. This agreement suggests that our computational procedures can be applied to answer practical questions, such as whether the connective heat flux from a given fire in a real room would be sufficient to trigger sprinklers or other detection systems in a given amount of time.
The Technique of the Film Cutting Room.
ERIC Educational Resources Information Center
Walter, Ernest
This book is more concerned with the "physical" in contrast to the "artistic" problems of the editing process. The functions of the editor and his assistants in relation to each stage in the production of a large-scale film are described in detail. All the routine operations of the editing room are discussed, from the receipt and documentation of…
Space Laboratory on a Table Top: A Next Generative ECLSS design and diagnostic tool
NASA Technical Reports Server (NTRS)
Ramachandran, N.
2005-01-01
This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale-time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations. Preliminary experimental and modeling work in this area will be presented. This involves testing of a single inlet-exit model with detailed 3-D flow visualization and quantitative diagnostics and computational modeling of the system.
Doyle, Richard J; Wang, Nina; Anthony, David; Borkan, Jeffrey; Shield, Renee R; Goldman, Roberta E
2012-10-01
We compared physicians' self-reported attitudes and behaviours regarding electronic health record (EHR) use before and after installation of computers in patient examination rooms and transition to full implementation of an EHR in a family medicine training practice to identify anticipated and observed effects these changes would have on physicians' practices and clinical encounters. We conducted two individual qualitative interviews with family physicians. The first interview was before and second interview was 8 months later after full implementation of an EHR and computer installation in the examination rooms. Data were analysed through project team discussions and subsequent coding with qualitative analysis software. At the first interviews, physicians frequently expressed concerns about the potential negative effect of the EHR on quality of care and physician-patient interaction, adequacy of their skills in EHR use and privacy and confidentiality concerns. Nevertheless, most physicians also anticipated multiple benefits, including improved accessibility of patient data and online health information. In the second interviews, physicians reported that their concerns did not persist. Many anticipated benefits were realized, appearing to facilitate collaborative physician-patient relationships. Physicians reported a greater teaching role with patients and sharing online medical information and treatment plan decisions. Before computer installation and full EHR implementation, physicians expressed concerns about the impact of computer use on patient care. After installation and implementation, however, many concerns were mitigated. Using computers in the examination rooms to document and access patients' records along with online medical information and decision-making tools appears to contribute to improved physician-patient communication and collaboration.
Interior building details of Building D, Room DM5: mezzanine hallway, ...
Interior building details of Building D, Room D-M5: mezzanine hallway, intact historic asphalt surface flooring, full height partition wall with hoppers and east brick retaining wall with voids from the original veiling joist; southerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
76 FR 17353 - Aviation Communications
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-29
... publication). The full text of this document is available for public inspection and copying during regular... Printing, Inc., 445 12th Street, SW., Room CY-B402, Washington, DC 20554. The full text may also be...
Human factors engineering verification and validation for APR1400 computerized control room
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shin, Y. C.; Moon, H. K.; Kim, J. H.
2006-07-01
This paper introduces the Advanced Power Reactor 1400 (APR1400) HFE V and V activities the Korea Hydro Nuclear Plant Co. LTD. (KHNP) has performed for the last 10 years and some of the lessons learned through these activities. The features of APR1400 main control room include large display panel, redundant compact workstations, computer-based procedure, and safety console. Several iterations of human factors evaluations have been performed from small scale proof of concept tests to large scale integrated system tests for identifying human engineering deficiencies in the human system interface design. Evaluations in the proof of concept test were focused onmore » checking the presence of any show stopper problems in the design concept. Later evaluations were mostly for finding design problems and for assuring the resolution of human factors issues of advanced control room. The results of design evaluations were useful not only for refining the control room design, but also for licensing the standard design. Several versions of APR1400 mock-ups with dynamic simulation models of currently operating Korea Standard Nuclear Plant (KSNP) have been used for the evaluations with the participation of operators from KSNP plants. (authors)« less
NASA Astrophysics Data System (ADS)
Tecle, Amanuel Sebhatu
Hurricane is one of the most destructive and costly natural hazard to the built environment and its impact on low-rise buildings, particularity, is beyond acceptable. The major objective of this research was to perform a parametric evaluation of internal pressure (IP) for wind-resistant design of low-rise buildings and wind-driven natural ventilation applications. For this purpose, a multi-scale experimental, i.e. full-scale at Wall of Wind (WoW) and small-scale at Boundary Layer Wind Tunnel (BLWT), and a Computational Fluid Dynamics (CFD) approach was adopted. This provided new capability to assess wind pressures realistically on internal volumes ranging from small spaces formed between roof tiles and its deck to attic to room partitions. Effects of sudden breaching, existing dominant openings on building envelopes as well as compartmentalization of building interior on the IP were systematically investigated. Results of this research indicated: (i) for sudden breaching of dominant openings, the transient overshooting response was lower than the subsequent steady state peak IP and internal volume correction for low-wind-speed testing facilities was necessary. For example a building without volume correction experienced a response four times faster and exhibited 30--40% lower mean and peak IP; (ii) for existing openings, vent openings uniformly distributed along the roof alleviated, whereas one sided openings aggravated the IP; (iii) larger dominant openings exhibited a higher IP on the building envelope, and an off-center opening on the wall exhibited (30--40%) higher IP than center located openings; (iv) compartmentalization amplified the intensity of IP and; (v) significant underneath pressure was measured for field tiles, warranting its consideration during net pressure evaluations. The study aimed at wind driven natural ventilation indicated: (i) the IP due to cross ventilation was 1.5 to 2.5 times higher for Ainlet/Aoutlet>1 compared to cases where Ainlet/Aoutlet<1, this in effect reduced the mixing of air inside the building and hence the ventilation effectiveness; (ii) the presence of multi-room partitioning increased the pressure differential and consequently the air exchange rate. Overall good agreement was found between the observed large-scale, small-scale and CFD based IP responses. Comparisons with ASCE 7-10 consistently demonstrated that the code underestimated peak positive and suction IP.
Wax, Joseph R; Pinette, Michael G; Carpenter, Molly; Chard, Renée; Blackstone, Jacquelyn; Cartin, Angelina
2005-10-01
To determine whether pain associated with second trimester genetic amniocentesis is decreased by using subfreezing rather than room temperature needles. Subjects were randomized to a -14 degrees C or room temperature (20-22 degrees C) 22-gauge spinal needle. Patients, blinded to allocation, recorded anticipated and actual pain before and after the procedure, respectively, using a 0-10 visual analog scale with 0 = no pain and 10 = excruciating pain. Thirty-three subjects were randomized to room temperature and 29 subjects to subfreezing needles. Anticipated pain was similar in room temperature, 5.1 +/- 1.7, and subfreezing groups, 4.9 +/- 2.0, respectively (p = 0.6). Actual pain was also similar in the room temperature, 3.6 +/- 2.0, and subfreezing groups, 2.8 +/- 2.0, respectively (p = 0.14). Similar numbers of subjects in the room temperature and subfreezing groups reported less actual pain (20 vs. 18), greater actual pain (4 vs. 4) or no difference in pain (9 vs. 5) than anticipated (p = 0.6). A subfreezing 22-gauge spinal needle does not decrease perceived pain associated with second trimester genetic amniocentesis.
Wiglesworth, Sophie; Farnworth, Louise
2016-09-01
Despite the increased use of sensory rooms, there is little published evidence related to their benefits. The purpose of this study was to explore staff and patient perspectives of the use of a sensory room in an Australian forensic mental health setting. Staff and patients on a forensic hospital unit were recruited for this study. Focus group data was obtained from the perspective of the healthcare staff. A sensory assessment identified patients' sensory preferences. The details of the patients sensory room use and stress experienced before and after using the sensory room were recorded. The results showed a mean decrease in stress that was attributed to the use of the sensory room. Stress reducing benefits of sensory room use may improve a patient's experience within a forensic mental health facility while applying a recovery approach. As a limitation of the study, patient stress was rated on an un-validated scale. Further research is needed for greater insight and evidence in evaluating the use of sensory rooms in forensic mental health settings in reducing stress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Academically Productive Talk in a College Classroom
ERIC Educational Resources Information Center
Rybakova, Katie; Whitt, Kate Cook
2017-01-01
The classic image of a college classroom often includes a professor standing at the front of a room or hall, often standing near a chalkboard or projector screen, lecturing to a room full of 30 to 100 students diligently taking notes. This model of instruction, often referred to as direct instruction, however, is grounded in somewhat-outdated…
Rasch analysis of the Trypophobia Questionnaire.
Imaizumi, Shu; Tanno, Yoshihiko
2018-02-14
This study aimed to assess Rasch-based psychometric properties of the Trypophobia Questionnaire measuring proneness to trypophobia, which refers to disgust and unpleasantness induced by the observation of clusters of objects (e.g., lotus seed pods). Rasch analysis was performed on data from 582 healthy Japanese adults. The results suggested that Trypophobia Questionnaire has a unidimensional structure with ordered response categories and sufficient person and item reliabilities, and that it does not have differential item functioning across sexes and age groups, whereas the targeting of the scale leaves room for improvements. When items that did not fit the Rasch model were removed, the shortened version showed slightly improved psychometric properties. However, results were not conclusive in determining whether the full or shortened version is better for practical use. Further assessment and validation are needed.
Shock wave propagation within a confined multi-chamber system
NASA Astrophysics Data System (ADS)
Julien, B.; Sochet, I.; Tadini, P.; Vaillant, T.
2018-07-01
The influence of a variation of the opening ratios of rooms and side walls on the propagation of a shock wave within a confined multi-chamber system is analyzed through the evolution of some of the shock parameters (maximum overpressure and positive impulse). The shock wave is generated by the detonation of a hemispherical gaseous charge in one of the rooms. Several small-scale experiments have been carried out using an adjustable model representative of a pyrotechnic workshop. Using the same approach as for a previous article dealing with the impact of the volume of the rooms, we were able to link the evolution of the arrival time of the shock wave within the building with the reference obtained in the free field. Moreover, using a new parameter taking into account the opening ratios of the rooms and side walls, a predictive law was developed to model the maximal overpressure in the rooms.
ERIC Educational Resources Information Center
Kuhlmeier, Valerie
2005-01-01
Many recent studies have explored young children's ability to use information from physical representations of space to guide search within the real world. In one commonly used procedure, children are asked to find a hidden toy in a room after observing a smaller toy being hidden in the analogous location in a scale model of the room.…
2015-01-01
Table 2: Segregation results in terms of STOI on a variety of novel noises (SNR=-2 dB) Babble-20 Cafeteria Factory Babble-100 Living Room Cafe Park...NOISEX-92 corpus [13], and a living room, a cafe and a park noise from the DEMAND corpus [12]. To put the performance of the noise-independent model in
Superior room-temperature ductility of typically brittle quasicrystals at small sizes
Zou, Yu; Kuczera, Pawel; Sologubenko, Alla; Sumigawa, Takashi; Kitamura, Takayuki; Steurer, Walter; Spolenak, Ralph
2016-01-01
The discovery of quasicrystals three decades ago unveiled a class of matter that exhibits long-range order but lacks translational periodicity. Owing to their unique structures, quasicrystals possess many unusual properties. However, a well-known bottleneck that impedes their widespread application is their intrinsic brittleness: plastic deformation has been found to only be possible at high temperatures or under hydrostatic pressures, and their deformation mechanism at low temperatures is still unclear. Here, we report that typically brittle quasicrystals can exhibit remarkable ductility of over 50% strains and high strengths of ∼4.5 GPa at room temperature and sub-micrometer scales. In contrast to the generally accepted dominant deformation mechanism in quasicrystals—dislocation climb, our observation suggests that dislocation glide may govern plasticity under high-stress and low-temperature conditions. The ability to plastically deform quasicrystals at room temperature should lead to an improved understanding of their deformation mechanism and application in small-scale devices. PMID:27515779
Clinical practices in the hospital care of healthy newborn infant in Brazil.
Moreira, Maria Elisabeth Lopes; Gama, Silvana Granado Nogueira da; Pereira, Ana Paula Esteves; Silva, Antonio Augusto Moura da; Lansky, Sônia; Souza Pinheiro, Rossiclei de; Carvalho Gonçalves, Annelise de; Carmo Leal, Maria do
2014-08-01
The aim of this study was to evaluate the care of healthy full-term newborns and to identify variations in childbirth care and practices in the first hour of life. We used data from the Birth in Brazil survey. Unadjusted and adjusted odds ratio (OR) of hospital-delivered care for the mother and during childbirth were estimated for the following outcomes: upper airways and gastric aspiration, use of inhaled oxygen, use of incubator, skin-to-skin contact after birth, rooming-in and breastfeeding in the delivery room and within the first hour of life. We observed wide variations in the care of healthy full-term newborn in the delivery room. Practices considered inadequate, such as use of inhaled oxygen, (9.5%) aspiration of airways (71.1%) and gastric suctioning (39.7%), and the use of incubator (8.8%) were excessively used. Breastfeeding in the delivery room was low (16%), even when the Baby-Friendly Hospital Initiative had been implemented (24%). The results suggest poor knowledge and compliance by health practitioners to good clinical practice. Such noncompliance was probably not due to the differences in resources, since most births take place in hospitals where the necessary resources are available.
Ott, T; Schmidtmann, I; Limbach, T; Gottschling, P F; Buggenhagen, H; Kurz, S; Pestel, G
2016-11-01
Simulation-based training (SBT) has developed into an established method of medical training. Studies focusing on the education of medical students have used simulation as an evaluation tool for defined skills. A small number of studies provide evidence that SBT improves medical students' skills in the clinical setting. Moreover, they were strictly limited to a few areas, such as the diagnosis of heart murmurs or the correct application of cricoid pressure. Other studies could not prove adequate transferability from the skills gained in SBT to the patient site. Whether SBT has an effect on medical students' skills in anesthesiology in the clinical setting is controversial. To explore this issue, we designed a prospective, randomized, single-blind trial that was integrated into the undergraduate anesthesiology curriculum of our department during the second year of the clinical phase of medical school. This study intended to explore the effect of SBT on medical students within the mandatory undergraduate anesthesiology curriculum of our department in the operating room with respect to basic skills in anesthesiology. After obtaining ethical approval, the participating students of the third clinical semester were randomized into two groups: the SIM-OR group was trained by a 225 min long SBT in basic skills in anesthesiology before attending the operating room (OR) apprenticeship. The OR-SIM group was trained after the operating room apprenticeship by SBT. During SBT the students were trained in five clinical skills detailed below. Further, two clinical scenarios were simulated using a full-scale simulator. The students had to prepare the patient and perform induction of anesthesia, including bag-mask ventilation after induction in scenario 1 and rapid sequence induction in scenario 2. Using the five-point Likert scale, five defined skills were evaluated at defined time points during the study period. 1) application of the safety checklist, 2) application of basic patient monitoring, 3) establishment of intravenous access, 4) bag-and-mask ventilation, and 5) adjustment of ventilatory parameters after the patients' airways were secured. A cumulative score of 5 points was defined as the best and a cumulative score of 25 as the worst rating for a defined time point. The primary endpoint was the cumulative score after day 1 in the operating room apprenticeship and the difference in cumulative scores from days 1 to 4. Our hypothesis was that the SIM-OR group would achieve a better score after day 1 in the operating room apprenticeship and would gain a larger increase in score from day 1 to day 4 than the OR-SIM group. 73 students were allocated to the OR-SIM group and 70 students to the SIM-OR group. There was no significant difference between the two groups after day 1 of the operating room apprenticeship and no difference in increase of the cumulative score from day 1 to day 4 (median of cumulative score on day 1: 'SIM-OR' 11.2 points vs. 'OR-SIM' 14.6 points; p = 0.067; median of difference from day 1 to day 4: 'SIM-OR' -3.7 vs. 'OR-SIM' -6.4; p = 0.110). With the methods applied, this study could not prove that 225 min of SBT before the operating room apprenticeship increased the medical students' clinical skills as evaluated in the operating room. Secondary endpoints indicate that medical students have better clinical skills at the end of the entire curriculum when they have been trained through SBT before the operating room apprenticeship. However, the authors believe that simulator training has a positive impact on students' acquisition of procedural and patient safety skills, even if the methods applied in this study may not mirror this aspect sufficiently.
Adir, Y; Bitterman, H; Kol, S; Melamed, Y
1991-01-01
During the recent Persian Gulf war, the civilian population in Israel was frequently instructed to stay in sealed rooms in preparation for a possible chemical missile attack. The war broke out in mid-winter, and in many instances it was necessary to heat the rooms. The use of open fires or malfunctioning heating appliances inside sealed rooms could create ideal conditions for carbon monoxide (CO) poisoning. Six patients with CO intoxication resulting from confinement inside sealed rooms were referred for hyperbaric oxygen (HBO) treatment. Indications for HBO therapy were loss of consciousness and metabolic acidosis. The treatment protocol consisted of 90-min exposure to 100% oxygen at 2.5 atmospheres absolute (ATA), with repeated exposures when required. All patients made a full recovery. The risk of CO poisoning should be taken into consideration and should determine the selection of heating devices for future use in similar circumstances.
Larsson, Madeleine; Truong, Xu-Bin; Björn, Annika; Ejlertsson, Jörgen; Bastviken, David; Svensson, Bo H; Karlsson, Anna
2015-01-01
Anaerobic digestion of alkaline kraft elemental chlorine-free bleaching wastewater in two mesophilic, lab-scale upflow anaerobic sludge bed reactors resulted in significantly higher biogas production (250±50 vs. 120±30 NmL g [Formula: see text]) and reduction of filtered total organic carbon (fTOC) (60±5 vs. 43±6%) for wastewater from processing of hardwood (HW) compared with softwood (SW). In all cases, the gas production was likely underestimated due to poor gas separation in the reactors. Despite changes in wastewater characteristics, a stable anaerobic process was maintained with hydraulic retention times (HRTs) between 7 and 14 h. Lowering the HRT (from 13.5 to 8.5 h) did not significantly affect the process, and the stable performance at 8.5 h leaves room for further decreases in HRT. The results show that this type of wastewater is suitable for a full-scale implementation, but the difference in methane potential between SW and HW is important to consider both regarding process dimensioning and biogas yield optimization.
On the (a)symmetry between the perception of time and space in large-scale environments.
Riemer, Martin; Shine, Jonathan P; Wolbers, Thomas
2018-04-23
Cross-dimensional interference between spatial and temporal processing is well documented in humans, but the direction of these interactions remains unclear. The theory of metaphoric structuring states that space is the dominant concept influencing time perception, whereas time has little effect upon the perception of space. In contrast, theories proposing a common neuronal mechanism representing magnitudes argue for a symmetric interaction between space and time perception. Here, we investigated space-time interactions in realistic, large-scale virtual environments. Our results demonstrate a symmetric relationship between the perception of temporal intervals in the supra-second range and room size (experiment 1), but an asymmetric relationship between the perception of travel time and traveled distance (experiment 2). While the perception of time was influenced by the size of virtual rooms and by the distance traveled within these rooms, time itself affected only the perception of room size, but had no influence on the perception of traveled distance. These results are discussed in the context of recent evidence from rodent studies suggesting that subsets of hippocampal place and entorhinal grid cells can simultaneously code for space and time, providing a potential neuronal basis for the interactions between these domains. © 2018 Wiley Periodicals, Inc.
Knauert, Melissa; Jeon, Sangchoon; Murphy, Terrence E.; Yaggi, H. Klar; Pisani, Margaret A.; Redeker, Nancy S.
2016-01-01
Purpose Sound levels in the intensive care unit (ICU) are universally elevated and are believed to contribute to sleep and circadian disruption. The purpose of this study is to compare overnight ICU sound levels and peak occurrence on A- versus C-weighted scales. Materials and Methods This was a prospective observational study of overnight sound levels in 59 medical ICU patient rooms. Sound level was recorded every 10 seconds on A- and C-weighted decibel scales. Equivalent sound level (Leq) and sound peaks were reported for full and partial night periods. Results The overnight A-weighted Leq of 53.6 dBA was well above World Health Organization (WHO) recommendations; overnight C-weighted Leq was 63.1 dBC (no WHO recommendations). Peak sound occurrence ranged from 1.8 to 23.3 times per hour. Illness severity, mechanical ventilation and delirium were not associated with Leq or peak occurrence. Leq and peak measures for A- and C-weighted decibel scales were significantly different from each other. Conclusions Sound levels in the medical ICU are high throughout the night. Patient factors were not associated with Leq or peak occurrence. Significant discordance between A- and C-weighted values suggests that low frequency sound is a meaningful factor in the medical ICU environment. PMID:27546739
Decomposition of potential efficiency gains from hospital mergers in Greece.
Flokou, Angeliki; Aletras, Vassilis; Niakas, Dimitris
2017-12-01
This paper evaluates the technical efficiency of 71 Greek public hospitals and examines potential efficiency gains from 13 candidate mergers among them. Efficiency assessments are performed using bootstrapped Data Envelopment Analysis (DEA) whilst merger analysis is conducted by applying the Bogetoft and Wang methodology which allows the overall potential merger gains to be decomposed into three main components of inefficiency, namely technical (or learning), scope (or harmony) and scale (or size) effects. Thus, the analysis provides important insights not only on the magnitude of the potential total efficiency gains but also on their sources. The overall analysis is conducted in the context of a complete methodological framework where methods for outlier detection, returns to scale identification, and bias corrections for DEA estimations are also applied. Mergers are analyzed under the assumptions of constant, variable and non-decreasing returns to scale in an input oriented DEA model with three inputs and three outputs. The main finding of the study indicates that almost all mergers show substantial potential room for efficiency improvement, which is mainly attributed to the pre-merger technical inefficiencies of the individual hospitals and therefore it might be possible to be achieved without the need of implementing full-scale mergers. The same -though, at a lower extent- applies to the harmony effect whilst the size effect shows marginal or even negative gains.
Costa, Annamaria; Colosio, Claudio; Gusmara, Claudia; Sala, Vittorio; Guarino, Marcella
2014-01-01
In the last decades, large-scale swine production has led to intensive rearing systems in which air quality can be easily degraded by aerial contaminants that can pose a health risk to the pigs and farm workers. This study evaluated the effects of fogging disinfectant procedure on productive performance, ammonia and dust concentration, aerobic bacteria and fungal spores spreading in the farrowing-weaning room. This trial was conducted in 2 identical farrowing-weaning rooms of a piggery. In both rooms, 30 pregnant sows were lodged in individual cages. At 75 days of age, the piglets were moved to the fattening room. In the treated room, with the birth of the first suckling-pig, the fogging disinfection with diluted Virkon S was applied once a day in the experimental room per 15 minutes at 11:00. The fogging disinfectant treatment was switched between rooms at the end of the first trial period. Temperature, relative humidity, dust (TSP-RF fractions and number of particles), ammonia concentration and aerial contaminants (enterococci, Micrococcaeae and fungal spores) were monitored in both rooms. Ammonia concentration reduction induced by fogging disinfection was estimated 18%, total suspended particles and the respirable fraction were significantly lower in the experimental room. Fungal spores resulted in a significant reduction by the fogging procedure, together with dust respirable fraction and fine particulate matter abatement. The fogging disinfection procedure improved air quality in the piggery, thereby enhancing workers and animals health.
Shot-noise-limited magnetometer with sub-picotesla sensitivity at room temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucivero, Vito Giovanni, E-mail: vito-giovanni.lucivero@icfo.es; Anielski, Pawel; Gawlik, Wojciech
2014-11-15
We report a photon shot-noise-limited (SNL) optical magnetometer based on amplitude modulated optical rotation using a room-temperature {sup 85}Rb vapor in a cell with anti-relaxation coating. The instrument achieves a room-temperature sensitivity of 70 fT/√(Hz) at 7.6 μT. Experimental scaling of noise with optical power, in agreement with theoretical predictions, confirms the SNL behaviour from 5 μT to 75 μT. The combination of best-in-class sensitivity and SNL operation makes the system a promising candidate for application of squeezed light to a state-of-the-art atomic sensor.
Sodium-Rich Ferric Pyrophosphate Cathode for Stationary Room-Temperature Sodium-Ion Batteries.
Shen, Bolei; Xu, Maowen; Niu, Yubin; Han, Jin; Lu, Shiyu; Jiang, Jian; Li, Yi; Dai, Chunlong; Hu, Linyu; Li, Changming
2018-01-10
In this article, carbon-coated Na 3.64 Fe 2.18 (P 2 O 7 ) 2 nanoparticles (∼10 nm) were successfully synthesized via a facile sol-gel method and employed as cathode materials for sodium-ion batteries. The results show that the carbon-coated Na 3.64 Fe 2.18 (P 2 O 7 ) 2 cathode delivers a high reversible capacity of 99 mAh g -1 at 0.2 C, outstanding cycling life retention of 96%, and high Coulomb efficiency of almost 100% even after 1000 cycles at 10 C. Furthermore, the electrochemical performances of full batteries consisting of carbon-coated Na 3.64 Fe 2.18 (P 2 O 7 ) 2 nanoparticles as the cathode and commercialized hard carbon as the anode are tested. The full batteries exhibit a reversible capacity of 86 mAh g -1 at 0.5 C and capacity retention of 80% after 100 cycles. Therefore, the above-mentioned cathode is a potential candidate for developing inexpensive sodium-ion batteries in large-scale energy storage with long life.
Vacuum system for room temperature X-ray lithography source (XLS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuchman, J.C.
1988-09-30
A prototype room-temperature X-Ray Lithography Source (XLS)was proposed to be built at Brookhaven National Laboratory as part of a technology-transfer- to-American-industry program. The overall machine comprises a full energy linac, a 170 meter long transport line, and a 39 meter circumference storage ring. The scope of this paper will be limited to describing the storage ring vacuum system. (AIP)
Vacuum system for room temperature X-ray lithography source (XLS)
NASA Astrophysics Data System (ADS)
Schuchman, J. C.
1988-09-01
A prototype room-temperature X-Ray Lithography Source (XLS)was proposed to be built at Brookhaven National Laboratory as part of a technology-transfer- to-American-industry program. The overall machine comprises a full energy linac, a 170 meter long transport line, and a 39 meter circumference storage ring. The scope of this paper will be limited to describing the storage ring vacuum system. (AIP)
ERIC Educational Resources Information Center
American Association of State Colleges and Universities, Washington, DC.
In 1980, full-time state resident undergraduate students attending AASCU-member institutions paid an average of $712 for tuition and fees, and $1,605 for room and board charges. These figures reflect a 10.6 percent average increase over 1979 costs. Including books and supplies, transportation, and personal expenses, the cost of college attendance…
Son, Dinh Thai; Yasuoka, Junko; Poudel, Krishna C; Otsuka, Keiko; Jimba, Masamine
2013-09-01
To explore the association between MMORPG addiction and mental health status, and between self-control ability and mental health status among young male MMORPG players in Hanoi, Vietnam. In this cross-sectional study, 10 computer game rooms were randomly selected out of 77 in five communes in Hanoi. From these game rooms, 350 MMORPG players were purposively recruited as a study group, of whom 344 completed the questionnaire. In the same five communes, 344 non-players were selected as a control group. An online game addiction scale, a self-control scale and the Vietnamese SRQ-20 were used to measure the degree of MMORPG addiction, self-control ability and level of mental disorders. MMORPG players had significantly higher mental disorders scale scores than non-players (p < .001). The strongest positive correlation was detected between MMORPG addiction scale scores and mental disorders scale scores (r = 0.730, p < .001). Self-control scale scores were negatively associated with mental disorders scale scores (r = -0.345, p < .001). The average amount of money spent on games per month, MMORPG addiction scale score and self-control scale score were considered the best predictors of a higher mental disorders scale score. Young, male MMORPG players with higher addiction scores were more likely to have higher mental disorders scale scores, and such mental status was negatively associated with the level of self-control in Hanoi, Vietnam. Closer attention should be paid to prevent mental disorders among MMORPG players.
52. Photocopy of scale drawing (from Station 'L' office files, ...
52. Photocopy of scale drawing (from Station 'L' office files, Portland, Oregon) Portland General Electric in house drawing, 1930 PLAN OF THE TURBINE ROOM BUILDING L1 SHOWING THE ARRANGEMENT OF TURBINE UNITS 1-4 - Portland General Electric Company, Station "L", 1841 Southeast Water Street, Portland, Multnomah County, OR
Full wafer size investigation of N+ and P+ co-implanted layers in 4H-SiC
NASA Astrophysics Data System (ADS)
Blanqué, S.; Lyonnet, J.; Pérez, R.; Terziyska, P.; Contreras, S.; Godignon, P.; Mestres, N.; Pascual, J.; Camassel, J.
2005-03-01
We report a full wafer size investigation of the homogeneity of electrical properties in the case of co-implanted nitrogen and phosphorus ions in 4H-SiC semi-insulating wafers. To match standard industrial requirements, implantation was done at room temperature. To achieve a detailed electrical knowledge, we worked on a 35 mm wafer on which 77 different reticules have been processed. Every reticule includes one Hall cross, one Van der Pauw test structure and different TLM patterns. Hall measurements have been made on all 77 different reticules, using an Accent HL5500 Hall System® from BioRad fitted with an home-made support to collect data from room temperature down to about 150 K. At room temperature, we find that the sheet carrier concentration is only 1/4 of the total implanted dose while the average mobility is 80.6 cm2/Vs. The standard deviation is, typically, 1.5 cm2/Vs.
[Minimally invasive surgery and robotic surgery: surgery 4.0?].
Feußner, H; Wilhelm, D
2016-03-01
Surgery can only maintain its role in a highly competitive environment if results are continuously improved, accompanied by further reduction of the interventional trauma for patients and with justifiable costs. Significant impulse to achieve this goal was expected from minimally invasive surgery and, in particular, robotic surgery; however, a real breakthrough has not yet been achieved. Accordingly, the new strategic approach of cognitive surgery is required to optimize the provision of surgical treatment. A full scale integration of all modules utilized in the operating room (OR) into a comprehensive network and the development of systems with technical cognition are needed to upgrade the current technical environment passively controlled by the surgeon into an active collaborative support system (surgery 4.0). Only then can the true potential of minimally invasive surgery and robotic surgery be exploited.
Ortho and para hydrogen dimers on G/SiC(0001): combined STM and DFT study.
Merino, P; Švec, M; Martínez, J I; Mutombo, P; Gonzalez, C; Martín-Gago, J A; de Andres, P L; Jelinek, P
2015-01-01
The hydrogen (H) dimer structures formed upon room-temperature H adsorption on single layer graphene (SLG) grown on SiC(0001) are addressed using a combined theoretical-experimental approach. Our study includes density functional theory (DFT) calculations for the full (6√3 × 6√3)R30° unit cell of the SLG/SiC(0001) substrate and atomically resolved scanning tunneling microscopy images determining simultaneously the graphene lattice and the internal structure of the H adsorbates. We show that H atoms normally group in chemisorbed coupled structures of different sizes and orientations. We make an atomic scale determination of the most stable experimental geometries, the small dimers and ellipsoid-shaped features, and we assign them to hydrogen adsorbed in para dimers and ortho dimers configuration, respectively, through comparison with the theory.
Sekine, Yoshika; Fukuda, Mitsuru; Takao, Yosuke; Ozano, Takahiro; Sakuramoto, Hikaru; Wang, Kuan Wei
2011-12-01
Urgent measures for indoor air pollution caused by volatile organic compounds are required in urban areas of China. Considering indoor air concentration levels and hazardous properties, formaldehyde and benzene should be given priority for pollution control in China. The authors proposed the use of air-cleaning devices, including stand-alone room air cleaners and in-duct devices. This study aimed to find the best combination of sorption and decomposition filters for the simultaneous removal of formaldehyde and benzene, employing four types of air filter units: an activated charcoal filter (ACF), an ACF impregnated with a trapping agent for acidic gases (ACID), a MnO2 filter (MDF) for oxidative decomposition of formaldehyde at room temperature and a photocatalyst filter (PHOTO) coupled with a parallel beam ultraviolet (UV) irradiation device. The performance of the combined systems under air flow rates of 35-165 m3 h(-1) was evaluated in a test chamber (2 m3) with a constant gas generation system. The experimental results and data analysis using a kinetic approach showed the combined system of ACF, PHOTO and MDF significantly reduced both concentrations of formaldehyde and benzene in air without any unpleasant odours caused by the UV-induced photocatalytic reaction. The system was then evaluated in a full-size laboratory (22 m3). This test proved the practical performance of the system even at full scale, and also suggested that the filters should be arranged in the order of PHOTO/ACF/MDF from upstream to downstream. The proposed system has the potential of being used for improving indoor air quality of houses and buildings in China.
Human Factors and Technical Considerations for a Computerized Operator Support System Prototype
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ulrich, Thomas Anthony; Lew, Roger Thomas; Medema, Heather Dawne
2015-09-01
A prototype computerized operator support system (COSS) has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Departmentmore » of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment. A COSS demonstration scenario has been developed for the prototype involving the Chemical & Volume Control System (CVCS) of the PWR simulator. It involves a primary coolant leak outside of containment that would require tripping the reactor if not mitigated in a very short timeframe. The COSS prototype presents a series of operator screens that provide the needed information and soft controls to successfully mitigate the event.« less
NASA Astrophysics Data System (ADS)
Wang, Ximei; Zhu, Liqun; Li, Weiping; Liu, Huicong; Li, Yihong
2009-03-01
Anodic films have been prepared on the AZ91D magnesium alloys in 1 mol/L Na 2SiO 3 with 10 vol.% silica sol addition under the constant voltage of 60 V at room temperature by half-wave and full-wave power sources. The weight of the anodic films has been scaled by analytical balance, and the thickness has been measured by eddy current instrument. The surface morphologies, chemical composition and structure of the anodic films have been characterized by scanning electron microscopy (SEM), energy dispersion spectrometry (EDS), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the thickness and weight of the anodic films formed by the two power sources both increase with the anodizing time, and the films anodized by full-wave power source grow faster than that by half-wave one. Furthermore, we have fitted polynomial to the scattered data of the weight and thickness in a least-squares sense with MATLAB, which could express the growth process of the anodic films sufficiently. The full-wave power source is inclined to accelerate the growth of the anodic films, and the half-wave one is mainly contributed to the uniformity and fineness of the films. The anodic film consists of crystalline Mg 2SiO 4 and amorphous SiO 2.
Menzel, A; Matiu, M; Michaelis, R; Jochner, S
2017-05-01
Indoor pollen concentrations are an underestimated human health issue. In this study, we measured hourly indoor birch pollen concentrations on 8 days in April 2015 with portable pollen traps in five rooms of a university building at Freising, Germany. These data were compared to the respective outdoor values right in front of the rooms and to background pollen data. The rooms were characterized by different aspects and window ventilation schemes. Meteorological data were equally measured directly in front of the windows. Outdoor concentration could be partly explained with phenological data of 56 birches in the surrounding showing concurrent high numbers of trees attaining flowering stages. Indoor pollen concentrations were lower than outdoor concentrations: mean indoor/outdoor (I/O) ratio was highest in a room with fully opened window and additional mechanical ventilation (.75), followed by rooms with fully opened windows (.35, .12) and lowest in neighboring rooms with tilted window (.19) or windows only opened for short ventilation (.07). Hourly I/O ratios depended on meteorology and increased with outside temperature and wind speed oriented perpendicular to the window opening. Indoor concentrations additionally depended on the previously measured concentrations, indicating accumulation of pollen inside the rooms even after the full flowering period. © 2016 The Authors. Indoor Air Published by John Wiley & Sons Ltd.
Point clouds segmentation as base for as-built BIM creation
NASA Astrophysics Data System (ADS)
Macher, H.; Landes, T.; Grussenmeyer, P.
2015-08-01
In this paper, a three steps segmentation approach is proposed in order to create 3D models from point clouds acquired by TLS inside buildings. The three scales of segmentation are floors, rooms and planes composing the rooms. First, floor segmentation is performed based on analysis of point distribution along Z axis. Then, for each floor, room segmentation is achieved considering a slice of point cloud at ceiling level. Finally, planes are segmented for each room, and planes corresponding to ceilings and floors are identified. Results of each step are analysed and potential improvements are proposed. Based on segmented point clouds, the creation of as-built BIM is considered in a future work section. Not only the classification of planes into several categories is proposed, but the potential use of point clouds acquired outside buildings is also considered.
Reverberant acoustic energy in auditoria that comprise systems of coupled rooms
NASA Astrophysics Data System (ADS)
Summers, Jason Erik
A frequency-dependent model for levels and decay rates of reverberant energy in systems of coupled rooms is developed and compared with measurements conducted in a 1:10 scale model and in Bass Hall, Fort Worth, TX. Schroeder frequencies of subrooms, fSch, characteristic size of coupling apertures, a, relative to wavelength lambda, and characteristic size of room surfaces, l, relative to lambda define the frequency regions. At high frequencies [HF (f >> f Sch, a >> lambda, l >> lambda)], this work improves upon prior statistical-acoustics (SA) coupled-ODE models by incorporating geometrical-acoustics (GA) corrections for the model of decay within subrooms and the model of energy transfer between subrooms. Previous researchers developed prediction algorithms based on computational GA. Comparisons of predictions derived from beam-axis tracing with scale-model measurements indicate that systematic errors for coupled rooms result from earlier tail-correction procedures that assume constant quadratic growth of reflection density. A new algorithm is developed that uses ray tracing rather than tail correction in the late part and is shown to correct this error. At midfrequencies [MF (f >> f Sch, a ˜ lambda)], HF models are modified to account for wave effects at coupling apertures by including analytically or heuristically derived power transmission coefficients tau. This work improves upon prior SA models of this type by developing more accurate estimates of random-incidence tau. While the accuracy of the MF models is difficult to verify, scale-model measurements evidence the expected behavior. The Biot-Tolstoy-Medwin-Svensson (BTMS) time-domain edge-diffraction model is newly adapted to study transmission through apertures. Multiple-order BTMS scattering is theoretically and experimentally shown to be inaccurate due to the neglect of slope diffraction. At low frequencies (f ˜ f Sch), scale-model measurements have been qualitatively explained by application of previously developed perturbation models. Measurements newly confirm that coupling strength between three-dimensional rooms is related to unperturbed pressure distribution on the coupling surface. In Bass Hall, measurements are conducted to determine the acoustical effects of the coupled stage house on stage and in the audience area. The high-frequency predictions of statistical- and geometrical-acoustics models agree well with measured results. Predictions of the transmission coefficients of the coupling apertures agree, at least qualitatively, with the observed behavior.
Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control.
Miller-Leiden, S; Lobascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
Effectiveness of In-Room Air Filtration and Dilution Ventilation for Tuberculosis Infection Control.
Miller-Leiden, S; Lohascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
Bloom, T F; Egeland, G M
1999-01-01
Exposures to 1,1,2-trichloro-1,2,2-trifluoroethane or fluorocarbon (FC) 113 were evaluated in a horizontal laminar airflow (HLAF) clean room and a vertical laminar airflow (VLAF) clean room. A full period consecutive samples measurement strategy was employed. Data were used to calculate 8-hour time-weighted averages (8-TWA) for major work groups and to characterize exposures associated with specific cleaning tasks. The MIRAN 1B infrared analyzer was used to estimate peak concentrations. In the HLAF clean room, 8-TWAs ranged from 193 to 439 ppm; in the VLAF clean room, 8-TWAs ranged from 110 to 935 ppm. These levels were below the current Occupational Safety and Health Administration permissible exposure limit and the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit for FC 113 of 1000 ppm. Short-term sample concentrations ranged from 104 ppm (inspection) to 1080 ppm (assembly) in the HLAF clean room and 51 ppm (packaging)-3380 ppm (flushing) in the VLAF clean room. In the VLAF clean room, several short-term concentrations measured during the flushing task--1421 ppm and 2522 ppm--were above the NIOSH short-term exposure limit (STEL) of 1250 ppm. These data suggest the possibility that the STEL may be exceeded for tasks involving direct work with liquid FC 113. Peak exposure levels may be reduced by modification of worker position in the HLAF clean room and by use of open wire tables in the VLAF clean room.
Dangerous (toxic) atmospheres in UK wood pellet and wood chip fuel storage.
Simpson, Andrew T; Hemingway, Michael A; Seymour, Cliff
2016-09-01
There is growing use of wood pellet and wood chip boilers in the UK. Elsewhere fatalities have been reported, caused by carbon monoxide poisoning following entry into wood pellet storage areas. The aim of this work was to obtain information on how safely these two fuels are being stored in the UK. Site visits were made to six small-scale boiler systems and one large-scale pellet warehouse, to assess storage practice, risk management systems and controls, user knowledge, and potential for exposure to dangerous atmospheres. Real time measurements were made of gases in the store rooms and during laboratory tests on pellets and chips. Volatile organic compounds (VOCs) emitted and the microbiological content of the fuel was also determined. Knowledge of the hazards associated with these fuels, including confined space entry, was found to be limited at the smaller sites, but greater at the large pellet warehouse. There has been limited risk communication between companies supplying and maintaining boilers, those manufacturing and supplying fuel, and users. Risk is controlled by restricting access to the store rooms with locked entries; some store rooms have warning signs and carbon monoxide alarms. Nevertheless, some store rooms are accessed for inspection and maintenance. Laboratory tests showed that potentially dangerous atmospheres of carbon monoxide and carbon dioxide, with depleted levels of oxygen may be generated by these fuels, but this was not observed at the sites visited. Unplanned ventilation within store rooms was thought to be reducing the build-up of dangerous atmospheres. Microbiological contamination was confined to wood chips.
Dangerous (toxic) atmospheres in UK wood pellet and wood chip fuel storage
Simpson, Andrew T.; Hemingway, Michael A.; Seymour, Cliff
2016-01-01
ABSTRACT There is growing use of wood pellet and wood chip boilers in the UK. Elsewhere fatalities have been reported, caused by carbon monoxide poisoning following entry into wood pellet storage areas. The aim of this work was to obtain information on how safely these two fuels are being stored in the UK. Site visits were made to six small-scale boiler systems and one large-scale pellet warehouse, to assess storage practice, risk management systems and controls, user knowledge, and potential for exposure to dangerous atmospheres. Real time measurements were made of gases in the store rooms and during laboratory tests on pellets and chips. Volatile organic compounds (VOCs) emitted and the microbiological content of the fuel was also determined. Knowledge of the hazards associated with these fuels, including confined space entry, was found to be limited at the smaller sites, but greater at the large pellet warehouse. There has been limited risk communication between companies supplying and maintaining boilers, those manufacturing and supplying fuel, and users. Risk is controlled by restricting access to the store rooms with locked entries; some store rooms have warning signs and carbon monoxide alarms. Nevertheless, some store rooms are accessed for inspection and maintenance. Laboratory tests showed that potentially dangerous atmospheres of carbon monoxide and carbon dioxide, with depleted levels of oxygen may be generated by these fuels, but this was not observed at the sites visited. Unplanned ventilation within store rooms was thought to be reducing the build-up of dangerous atmospheres. Microbiological contamination was confined to wood chips. PMID:27030057
Manganelli, Joe; Threatt, Anthony; Brooks, Johnell O; Healy, Stan; Merino, Jessica; Yanik, Paul; Walker, Ian; Green, Keith
2014-01-01
This article presents the results of an exploratory study in which 14 clinical and staff subject matter experts (SMEs) at a regional rehabilitation hospital were interviewed in order to understand how and why over-the-bed tables are used. It is important to understand how and why a device or environment is used when designing it, and not just what features and functions are preferred. This knowledge is valuable both for contextualizing user feature and function preferences and for characterizing and prioritizing design challenges and opportunities. Fourteen hospital clinical and support staff subject-matter experts participated in semi-structured interviews with scenario enactments in a medium-fidelity, full-scale mock-up of a typical patient room. During these interviews, they interacted with two personas played by actors and were asked to enact an example of a normal visit, from entering the room through treatment/service and then exiting. Data were analyzed via methodological triangulation including frequency analysis, content analysis, and affinity diagramming. The results include a use-case analysis with illustrative sketches, a list of needs statements, and final observations. Successfully using the over-the-bed table is dependent upon proper positioning, especially in bed during meals. There are fewer problems associated with over-the-bed table use while seated in a chair than when in the bed. The over-the-bed table is a key component in acute care, inpatient therapies. Clinicians are generally open to "smart" furniture in the patient room but question its cost-effectiveness, robustness, and flexibility. Evidence-based design, human factors, patient-centered care, quality care, technology.
Zerhouni, Oulmann; Bègue, Laurent; Brousse, Georges; Carpentier, Françoise; Dematteis, Maurice; Pennel, Lucie; Swendsen, Joel; Cherpitel, Cheryl
2013-01-01
Our objective is to present a focused review of the scientific literature on the effect of alcohol consumption on violence related-injuries assessed in the emergency room (ER) and to show how psychological and behavioral sciences could lead to a better understanding of the factors contributing to alcohol-related injuries in the ER. We retrieved published literature through a detailed search in Academic Search Premier, MEDLINE with Full Text PsycARTICLES, Psychology and Behavioral Sciences Collection, PsycINFO, PUBMed and SocINDEX with Full Text for articles related to emergency rooms, medical problems and sociocognitive models addressing alcohol intoxication articles. The first search was conducted in June 2011 and updated until August 2013. Literature shows that compared to uninjured patients; injured ones have a higher probability of: (i) having an elevated blood-alcohol concentration upon arrival at the ER; (ii) reporting having drunk alcohol during the six hours preceding the event; and (iii) suffering from drinking-related consequences that adversely affect their social life. The main neurocognitive and sociocognitive models on alcohol and aggression are also discussed in order to understand the aetiology of violence-related injuries in emergency rooms. Suggestions are made for future research and prevention. PMID:24084671
Hydrogen attack - Influence of hydrogen sulfide. [on carbon steel
NASA Technical Reports Server (NTRS)
Eliezer, D.; Nelson, H. G.
1978-01-01
An experimental study is conducted on 12.5-mm-thick SAE 1020 steel (plain carbon steel) plate to assess hydrogen attack at room temperature after specimen exposure at 525 C to hydrogen and a blend of hydrogen sulfide and hydrogen at a pressure of 3.5 MN/sq m for exposure times up to 240 hr. The results are discussed in terms of tensile properties, fissure formation, and surface scales. It is shown that hydrogen attack from a high-purity hydrogen environment is severe, with the formation of numerous methane fissures and bubbles along with a significant reduction in the room-temperature tensile yield and ultimate strengths. However, no hydrogen attack is observed in the hydrogen/hydrogen sulfide blend environment, i.e. no fissure or bubble formation occurred and the room-temperature tensile properties remained unchanged. It is suggested that the observed porous discontinuous scale of FeS acts as a barrier to hydrogen entry, thus reducing its effective equilibrium solubility in the iron lattice. Therefore, hydrogen attack should not occur in pressure-vessel steels used in many coal gasification processes.
Subjective scaling of spatial room acoustic parameters influenced by visual environmental cues
Valente, Daniel L.; Braasch, Jonas
2010-01-01
Although there have been numerous studies investigating subjective spatial impression in rooms, only a few of those studies have addressed the influence of visual cues on the judgment of auditory measures. In the psychophysical study presented here, video footage of five solo music∕speech performers was shown for four different listening positions within a general-purpose space. The videos were presented in addition to the acoustic signals, which were auralized using binaural room impulse responses (BRIR) that were recorded in the same general-purpose space. The participants were asked to adjust the direct-to-reverberant energy ratio (D∕R ratio) of the BRIR according to their expectation considering the visual cues. They were also directed to rate the apparent source width (ASW) and listener envelopment (LEV) for each condition. Visual cues generated by changing the sound-source position in the multi-purpose space, as well as the makeup of the sound stimuli affected the judgment of spatial impression. Participants also scaled the direct-to-reverberant energy ratio with greater direct sound energy than was measured in the acoustical environment. PMID:20968367
30. Photocopy of scale drawing (from Station 'L' office files, ...
30. Photocopy of scale drawing (from Station 'L' office files, Portland, Oregon) Portland General Electric in house drawing, c.1960 PLAN OF THE L.P. BOILER ROOM BUILDING L2 WHICH HOUSED THE ORIGINAL EIGHT BOILERS OF STATION 'L' - Portland General Electric Company, Station "L", 1841 Southeast Water Street, Portland, Multnomah County, OR
Janssen, Patricia A; Keen, Lois; Soolsma, Jetty; Seymour, Laurie C; Harris, Susan J; Klein, Michael C; Reime, Birgit
2005-01-01
To evaluate the success of a competency-based nursing orientation programme for a single-room maternity care unit by measuring improvement in self-reported competency after six months. Single-room maternity care has challenged obstetrical nurses to provide comprehensive nursing care during all phases of the in-hospital birth experience. In this model, nurses provide intrapartum, postpartum and newborn care in one room. To date, an evaluation of nursing education for single-room maternity care has not been published. A prospective cohort design comparing self-reported competencies prior to starting work in the single-room maternity care and six months after. Nurses completed a competency-based education programme in which they could select from a menu of learning methods and content areas according to their individual needs. Learning methods included classroom lectures, self-paced learning packages, and preceptorships in the clinical area. Competencies were measured by a standardized perinatal self-efficacy tool and a tool developed by the authors for this study, the Single-Room Maternity Care Competency Tool. A paired analysis was undertaken to take into account the paired (before and after) nature of the design. Scores on the perinatal self-efficacy scale and the single-room maternity care competency tool were improved. These differences were statistically significant. Improvements in perinatal and single-room maternity care-specific competencies suggest that our education programme was successful in preparing nurses for their new role in the single-room maternity care setting. This conclusion is supported by reported increases in nursing and patient satisfaction in the single-room maternity care compared with the traditional labour/delivery and postpartum settings. An education programme tailored to the learning needs of experienced clinical nurses contributes to improvements in nursing competencies and patient care.
A multidimensional framework for assessing patient room configurations.
Pati, Debajyoti; Harvey, Thomas E; Reyers, Evelyn; Evans, Jennie; Waggener, Laurie; Serrano, Marjorie; Saucier, Rachel; Nagle, Tina
2009-01-01
A framework for multidimensional assessment of patient room configurations is presented. Twenty-three issues are considered and categorized under six domains of assessment: (1) patient safety, (2) staff efficiency, (3) circulation, (4) infection control, (5) patient considerations, and (6) family amenities. Use of the framework to rank issues by importance and assess six alternative patient room configurations by a diverse group of experts in a symposium is described. One of the key questions posed during inpatient room design is the location of the bathroom. What issues are affected by the variations in room configuration that arise from bathroom location? A complete articulation of the issues that potentially are affected by room configuration is not available in the literature. The list of issues was developed by the authors in preparation for a symposium. The symposium was organized in May 2007 and attended by 14 experts from four institutions. Six alternative room configurations were used. Variations in the configurations included: (1) three same-handed and three mirror-image rooms; (2) three outboard, two inboard, and one nested bathroom; and (3) three rooms with footwall bathrooms and three with headwall bathrooms. In a four-step process, the attendees ranked the issues, discussed them in detail, rated each room configuration against each issue on a seven-point suitability scale, and conducted an overall assessment of the six configurations. Based on the ratings and rankings provided by the symposium participants, outboard bathroom locations were found to be most suitable, followed by nested and inboard configurations. Furthermore, configurations with patient bathrooms located on the footwall were rated as more suitable than headwall locations. The authors recommend, however, that the framework be used to determine a suitable room configuration in a specific context, rather than to identify configurations that will perform well universally.
On the accuracy of models for predicting sound propagation in fitted rooms.
Hodgson, M
1990-08-01
The objective of this article is to make a contribution to the evaluation of the accuracy and applicability of models for predicting the sound propagation in fitted rooms such as factories, classrooms, and offices. The models studied are 1:50 scale models; the method-of-image models of Jovicic, Lindqvist, Hodgson, Kurze, and of Lemire and Nicolas; the emprical formula of Friberg; and Ondet and Barbry's ray-tracing model. Sound propagation predictions by the analytic models are compared with the results of sound propagation measurements in a 1:50 scale model and in a warehouse, both containing various densities of approximately isotropically distributed, rectangular-parallelepipedic fittings. The results indicate that the models of Friberg and of Lemire and Nicolas are fundamentally incorrect. While more generally applicable versions exist, the versions of the models of Jovicic and Kurze studied here are found to be of limited applicability since they ignore vertical-wall reflections. The Hodgson and Lindqvist models appear to be accurate in certain limited cases. This preliminary study found the ray-tracing model of Ondet and Barbry to be the most accurate of all the cases studied. Furthermore, it has the necessary flexibility with respect to room geometry, surface-absorption distribution, and fitting distribution. It appears to be the model with the greatest applicability to fitted-room sound propagation prediction.
Yanke, Eric; Zellmer, Caroline; Van Hoof, Sarah; Moriarty, Helene; Carayon, Pascale; Safdar, Nasia
2015-01-01
Background Achieving and sustaining high levels of healthcare worker (HCW) compliance with contact isolation precautions is challenging. The aim of this study was to determine HCW work system barriers to, and facilitators of, adherence to contact isolation for patients with suspected or confirmed Clostridium difficile infection (CDI) using a human factors and systems engineering approach. Methods Prospective cohort study from September 2013 to November 2013 at a large academic medical center (hospital A) and an affiliated Veterans Administration (VA) hospital (hospital B). A human factors engineering (HFE) model for patient safety – the Systems Engineering Initiative for Patient Safety (SEIPS) model – was used to guide work system analysis and direct observation data collection. 288 observations were conducted. HCWs and visitors were assessed for compliance with all components of contact isolation precautions (hand hygiene, gowning, and gloving) before and after patient contact. Time required to complete contact isolation precautions was measured and adequacy of contact isolation supplies was assessed. Results Full compliance with contact isolation precautions was low at both hospitals: hospital A, 7%; hospital B, 22%. Lack of appropriate hand hygiene prior to room entry (Compliance: hospital A, 18%; hospital B, 29%) was the most common reason for lack of full compliance. More time was required for full compliance as compared to compliance with no components of contact isolation precautions before patient room entry, inside patient room, and after patient room exit (59.9 sec vs. 3.2 sec; P < .001; 507.3 sec vs. 149.7 sec; P = .006; 15.2 sec vs. 1.3 sec; P < .001). Compliance was lower when contact isolation supplies were inadequate (4% vs. 16%; P = .005). Conclusions Adherence to contact isolation precautions for CDI is a complex, time-consuming process. HFE analysis indicates multiple work system components serve as barriers and facilitators to full compliance with contact isolation precautions and should be addressed further to prevent CDI. PMID:25728149
Yanke, Eric; Zellmer, Caroline; Van Hoof, Sarah; Moriarty, Helene; Carayon, Pascale; Safdar, Nasia
2015-03-01
Achieving and sustaining high levels of health care worker (HCW) compliance with contact isolation precautions is challenging. The aim of this study was to determine HCW work system barriers to and facilitators of adherence to contact isolation for patients with suspected or confirmed Clostridium difficile infection (CDI) using a human factors and systems engineering approach. This prospective cohort study took place between September 2013 and November 2013 at a large academic medical center (hospital A) and an affiliated Veterans Administration hospital (hospital B). A human factors engineering (HFE) model for patient safety, the Systems Engineering Initiative for Patient Safety model, was used to guide work system analysis and direct observation data collection. There were 288 observations conducted. HCWs and visitors were assessed for compliance with all components of contact isolation precautions (hand hygiene, gowning, and gloving) before and after patient contact. Time required to complete contact isolation precautions was measured, and adequacy of contact isolation supplies was assessed. Full compliance with contact isolation precautions was low at both hospitals A (7%) and B (22%). Lack of appropriate hand hygiene prior to room entry (compliance for hospital A: 18%; compliance for hospital B: 29%) was the most common reason for lack of full compliance. More time was required for full compliance compared with compliance with no components of contact isolation precautions before patient room entry, inside patient room, and after patient room exit (59.9 vs 3.2 seconds, P < .001; 507.3 vs 149.7 seconds, P = .006; 15.2 vs 1.3 seconds, P < .001, respectively). Compliance was lower when contact isolation supplies were inadequate (4% vs 16%, P = .005). Adherence to contact isolation precautions for CDI is a complex, time-consuming process. HFE analysis indicates that multiple work system components serve as barriers and facilitators to full compliance with contact isolation precautions and should be addressed further to prevent CDI. Published by Elsevier Inc.
Lloyd-Hughes, J; Mosley, C D W; Jones, S P P; Lees, M R; Chen, A; Jia, Q X; Choi, E-M; MacManus-Driscoll, J L
2017-04-12
Colossal magnetoresistance (CMR) is demonstrated at terahertz (THz) frequencies by using terahertz time-domain magnetospectroscopy to examine vertically aligned nanocomposites (VANs) and planar thin films of La 0.7 Sr 0.3 MnO 3 . At the Curie temperature (room temperature), the THz conductivity of the VAN was dramatically enhanced by over 2 orders of magnitude under the application of a magnetic field with a non-Drude THz conductivity that increased with frequency. The direct current (dc) CMR of the VAN is controlled by extrinsic magnetotransport mechanisms such as spin-polarized tunneling between nanograins. In contrast, we find that THz CMR is dominated by intrinsic, intragrain transport: the mean free path was smaller than the nanocolumn size, and the planar thin-film exhibited similar THz CMR to the VAN. Surprisingly, the observed colossal THz magnetoresistance suggests that the magnetoresistance can be large for alternating current motion on nanometer length scales, even when the magnetoresistance is negligible on the macroscopic length scales probed by dc transport. This suggests that colossal magnetoresistance at THz frequencies may find use in nanoelectronics and in THz optical components controlled by magnetic fields. The VAN can be scaled in thickness while retaining a high structural quality and offers a larger THz CMR at room temperature than the planar film.
Lloyd-Hughes, James; Mosley, C. D. W.; Jones, S. P. P.; ...
2017-03-13
Colossal magnetoresistance (CMR) is demonstrated at terahertz (THz) frequencies by using terahertz time-domain magnetospectroscopy to examine vertically aligned nanocomposites (VANs) and planar thin films of La 0.7Sr 0.3MnO 3. At the Curie temperature (room temperature), the THz conductivity of the VAN was dramatically enhanced by over 2 orders of magnitude under the application of a magnetic field with a non-Drude THz conductivity that increased with frequency. The direct current (dc) CMR of the VAN is controlled by extrinsic magnetotransport mechanisms such as spin-polarized tunneling between nanograins. In contrast, we find that THz CMR is dominated by intrinsic, intragrain transport: themore » mean free path was smaller than the nanocolumn size, and the planar thin-film exhibited similar THz CMR to the VAN. Surprisingly, the observed colossal THz magnetoresistance suggests that the magnetoresistance can be large for alternating current motion on nanometer length scales, even when the magnetoresistance is negligible on the macroscopic length scales probed by dc transport. This suggests that colossal magnetoresistance at THz frequencies may find use in nanoelectronics and in THz optical components controlled by magnetic fields. As a result, the VAN can be scaled in thickness while retaining a high structural quality and offers a larger THz CMR at room temperature than the planar film.« less
Cartoon distraction alleviates anxiety in children during induction of anesthesia.
Lee, Jeongwoo; Lee, Jihye; Lim, Hyungsun; Son, Ji-Seon; Lee, Jun-Rae; Kim, Dong-Chan; Ko, Seonghoon
2012-11-01
We performed this study to determine the beneficial effects of viewing an animated cartoon and playing with a favorite toy on preoperative anxiety in children aged 3 to 7 years in the operating room before anesthesia induction. One hundred thirty children aged 3 to 7 years with ASA physical status I or II were enrolled. Subjects were randomly assigned to 1 of 3 groups: group 1 (control), group 2 (toy), and group 3 (animated cartoon). The children in group 2 were asked to bring their favorite toy and were allowed to play with it until anesthesia induction. The children in group 3 watched their selected animated cartoon until anesthesia induction. Children's preoperative anxiety was determined by the modified Yale Preoperative Anxiety Scale (mYPAS) and parent-recorded anxiety Visual Analog Scale (VAS) the night before surgery, in the preanesthetic holding room, and just before anesthesia induction. In the preanesthetic holding room, the group 2 mYPAS and parent-recorded anxiety VAS scores were significantly lower than those of groups 1 and 3 (mYPAS: P = 0.007; parent-recorded anxiety VAS: P = 0.02). In the operating room, the children in group 3 had the lowest mYPAS and parent-recorded anxiety VAS scores among the 3 groups (mYPAS: P < 0.001; parent-recorded anxiety VAS: P < 0.001). In group 3, the mYPAS and parent-recorded anxiety VAS scores of only 3 and 5 children were increased in the operating room compared with their scores in the preanesthetic holding room, whereas the anxiety scores of 32 and 34 children in group 1 and 25 and 32 children in group 2 had increased (P < 0.001). The number of children whose scores indicated no anxiety (mYPAS score <30) in the operating room was 3 (7%), 9 (23%), and 18 (43%) in groups 1, 2, and 3, respectively (P < 0.001). Allowing the viewing of animated cartoons by pediatric surgical patients is a very effective method to alleviate preoperative anxiety. Our study suggests that this intervention is an inexpensive, easy to administer, and comprehensive method for anxiety reduction in the pediatric surgical population.
126. View in Generator Room of exciter unit no. 1; ...
126. View in Generator Room of exciter unit no. 1; looking northwest. This unit includes a Pelton wheel manufactured by Allis Chalmers, no. 261, type C-1, Breaking Horse Power 600, head 370 feet, and 360 rpm; a General Electric DC generator, no. 1357609, type MPC 8, 340-350 form LD, 1360 amp, 350 rpm, 250 volts (no load), 250 volts (full load); and a General Electric induction motor, no. 4228863, type KT-4424, 20-500-360 form A, 60 cycles, 45 amp, 6,600 volts, 500 horsepower, continuous 50-degree centigrade rise, 350 rpm with full-load. Photo by Jet Lowe, HAER, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA
Villafranca, Alexander; Hamlin, Colin; Rodebaugh, Thomas L; Robinson, Sandra; Jacobsohn, Eric
2017-09-10
Disruptive intraoperative behavior has detrimental effects to clinicians, institutions, and patients. How clinicians respond to this behavior can either exacerbate or attenuate its effects. Previous investigations of disruptive behavior have used survey scales with significant limitations. The study objective was to develop appropriate scales to measure exposure and responses to disruptive behavior. We obtained ethics approval. The scales were developed in a sequence of steps. They were pretested using expert reviews, computational linguistic analysis, and cognitive interviews. The scales were then piloted on Canadian operating room clinicians. Factor analysis was applied to half of the data set for question reduction and grouping. Item response analysis and theoretical reviews ensured that important questions were not eliminated. Internal consistency was evaluated using Cronbach α. Model fit was examined on the second half of the data set using confirmatory factor analysis. Content validity of the final scales was re-evaluated. Consistency between observed relationships and theoretical predictions was assessed. Temporal stability was evaluated on a subsample of 38 respondents. A total of 1433 and 746 clinicians completed the exposure and response scales, respectively. Content validity indices were excellent (exposure = 0.96, responses = 1.0). Internal consistency was good (exposure = 0.93, responses = 0.87). Correlations between the exposure scale and secondary measures were consistent with expectations based on theory. Temporal stability was acceptable (exposure = 0.77, responses = 0.73). We have developed scales measuring exposure and responses to disruptive behavior. They generate valid and reliable scores when surveying operating room clinicians, and they overcome the limitations of previous tools. These survey scales are freely available.
Thomas, Anita A; Uspal, Neil G; Oron, Assaf P; Klein, Eileen J
2016-12-01
Just-in-time (JIT) training refers to education occurring immediately prior to clinical encounters. An in situ JIT room in a pediatric emergency department (ED) was created for procedural education. We examined trainee self-reported JIT room use, its impact on trainee self-perception of procedural competence/confidence, and the effect its usage has on the need for intervention by supervising physicians during procedures. Cross-sectional survey study of a convenience sample of residents rotating through the ED and supervising pediatric emergency medicine physicians. Outcomes included JIT room use, trainee procedural confidence, and frequency of supervisor intervention during procedures. Thirty-one of 32 supervising physicians (97%) and 122 of 186 residents (66%) completed the survey, with 71% of trainees reporting improved confidence, and 68% reporting improved procedural skills ( P < .05, +1.4-point average skills improvement on a 5-point Likert scale). Trainees perceived no difference among supervising physicians intervening in procedures with or without JIT room use ( P = .30, paired difference -0.0 points). Nearly all supervisors reported improved trainee procedural confidence, and 77% reported improved trainee procedural skills after JIT room use ( P < .05, paired difference +1.8 points); 58% of supervisors stated they intervene in procedures without trainee JIT room use, compared with 42% with JIT room use ( P < .05, paired difference -0.4 points). Use of the JIT room led to improved trainee confidence and supervisor reports of less procedural intervention. Although it carries financial and time costs, an in situ JIT room may be important for convenient JIT training.
Thomas, Anita A.; Uspal, Neil G.; Oron, Assaf P.; Klein, Eileen J.
2016-01-01
Background Just-in-time (JIT) training refers to education occurring immediately prior to clinical encounters. An in situ JIT room in a pediatric emergency department (ED) was created for procedural education. Objective We examined trainee self-reported JIT room use, its impact on trainee self-perception of procedural competence/confidence, and the effect its usage has on the need for intervention by supervising physicians during procedures. Methods Cross-sectional survey study of a convenience sample of residents rotating through the ED and supervising pediatric emergency medicine physicians. Outcomes included JIT room use, trainee procedural confidence, and frequency of supervisor intervention during procedures. Results Thirty-one of 32 supervising physicians (97%) and 122 of 186 residents (66%) completed the survey, with 71% of trainees reporting improved confidence, and 68% reporting improved procedural skills (P < .05, +1.4-point average skills improvement on a 5-point Likert scale). Trainees perceived no difference among supervising physicians intervening in procedures with or without JIT room use (P = .30, paired difference −0.0 points). Nearly all supervisors reported improved trainee procedural confidence, and 77% reported improved trainee procedural skills after JIT room use (P < .05, paired difference +1.8 points); 58% of supervisors stated they intervene in procedures without trainee JIT room use, compared with 42% with JIT room use (P < .05, paired difference −0.4 points). Conclusions Use of the JIT room led to improved trainee confidence and supervisor reports of less procedural intervention. Although it carries financial and time costs, an in situ JIT room may be important for convenient JIT training. PMID:28018542
Park, Seong-Hyun; Mattson, Richard H
2009-09-01
Clinical trials have not been reported concerning the health benefits of viewing indoor plants on stress and recovery of surgical patients within a hospital setting. Using various medical and psychologic measurements, this study performed a randomized clinical trial with surgical patients to evaluate whether plants in hospital rooms have therapeutic influences. Ninety (90) patients recovering from a hemorrhoidectomy were randomly assigned to either control or plant rooms. With half the patients, live plants were placed in their rooms during postoperative recovery periods. Data collected for each patient included length of hospitalization, analgesics used for postoperative pain control, vital signs, ratings of pain intensity, pain distress, anxiety and fatigue, the State-Trait Anxiety Inventory Form Y-1, the Environmental Assessment Scale, and the Patient's Room Satisfaction Questionnaire. Viewing plants during the recovery period had a positive influence linking directly to health outcomes of surgical patients. Patients in hospital rooms with plants and flowers had significantly more positive physiologic responses evidenced by lower systolic blood pressure, and lower ratings of pain, anxiety, and fatigue than patients in the control room. Patients with plants also felt more positively about their rooms and evaluated them with higher satisfaction when compared with patients in similar rooms without plants. Based on patients' comments, plants brightened up the room environment, reduced stress, and also conveyed positive impressions of hospital employees caring for patients. Findings of this study confirmed the therapeutic value of plants in the hospital environment as a noninvasive, inexpensive, and effective complementary medicine for surgical patients. Health care professionals and hospital administrators need to consider the use of plants and flowers to enhance healing environments for patients.
PBF Reactor Building (PER620). In subpile room, camera faces southeast ...
PBF Reactor Building (PER-620). In sub-pile room, camera faces southeast and looks up toward bottom of reactor vessel. Upper assembly in center of view is in-pile tube as it connects to vessel. Lower lateral constraints and rotating control cable are in position. Other connections have been bolted together. Note light bulbs for scale. Photographer: John Capek. Date: August 21, 1970. INEEL negative no. 70-3494 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
Hall, L. R.; Finger, R. W.
1972-01-01
Fracture and crack growth resistance characteristics of 304 stainless steel alloy weldments as relating to retesting of cryogenic vessels were examined. Welding procedures were typical of those used in full scale vessel fabrication. Fracture resistance survey tests were conducted in room temperature air, liquid nitrogen and liquid hydrogen. In air, both surface-flawed and center-cracked panels containing cracks in weld metal, fusion line, heat-affected zone, or parent metal were tested. In liquid nitrogen and liquid hydrogen, tests were conducted using center-cracked panels containing weld centerline cracks. Load-unload, sustained load, and cyclic load tests were performed in air or hydrogen gas, liquid nitrogen, and liquid hydrogen using surface-flawed specimens containing weld centerline cracks. Results were used to evaluate the effectiveness of periodic proof overloads in assuring safe and reliable operation of over-the-road cryogenic dewars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Yuanyuan; Browning, Nigel D.
As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelasticmore » scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Yuanyuan; Browning, Nigel D.
As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelasticmore » scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. Furthermore, we demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.« less
Actively cooled plate fin sandwich structural panels for hypersonic aircraft
NASA Technical Reports Server (NTRS)
Smith, L. M.; Beuyukian, C. S.
1979-01-01
An unshielded actively cooled structural panel was designed for application to a hypersonic aircraft. The design was an all aluminum stringer-stiffened platefin sandwich structure which used a 60/40 mixture of ethylene glycol/water as the coolant. Eight small test specimens of the basic platefin sandwich concept and three fatigue specimens from critical areas of the panel design was fabricated and tested (at room temperature). A test panel representative of all features of the panel design was fabricated and tested to determine the combined thermal/mechanical performance and structural integrity of the system. The overall findings are that; (1) the stringer-stiffened platefin sandwich actively cooling concept results in a low mass design that is an excellent contender for application to a hypersonic vehicle, and (2) the fabrication processes are state of the art but new or modified facilities are required to support full scale panel fabrication.
2011-02-15
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann
2011-02-15
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann
2011-02-15
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, training takes place atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann
2010-10-27
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, the 600-Ton Test Fixture outside the Launch Equipment Test Facility conducts a 500,000-pound pull test of a bridge crane lifting element, which is used to lift space shuttles in the Vehicle Assembly Building. The fixture proofload tests, in tension and compression, a variety of ground support equipment, including slings, lifting beams and other critical lifting hardware that require periodic proofloading. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, launch simulation towers and a cryogenic system. Photo credit: NASA/Jim Grossmann
2010-10-27
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, the 600-Ton Test Fixture outside the Launch Equipment Test Facility is prepared to conduct a 500,000-pound pull test of a bridge crane lifting element, which is used to lift space shuttles in the Vehicle Assembly Building. The fixture proofload tests, in tension and compression, a variety of ground support equipment, including slings, lifting beams and other critical lifting hardware that require periodic proofloading. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, launch simulation towers and a cryogenic system. Photo credit: NASA/Jim Grossmann
2011-02-15
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann
2010-10-27
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, the 600-Ton Test Fixture outside the Launch Equipment Test Facility conducts a 500,000-pound pull test of a bridge crane lifting element, which is used to lift space shuttles in the Vehicle Assembly Building. The fixture proofload tests, in tension and compression, a variety of ground support equipment, including slings, lifting beams and other critical lifting hardware that require periodic proofloading. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, launch simulation towers and a cryogenic system. Photo credit: NASA/Jim Grossmann
2011-02-15
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training on a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann
2010-10-27
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, the 600-Ton Test Fixture outside the Launch Equipment Test Facility conducts a 500,000-pound pull test of a bridge crane lifting element, which is used to lift space shuttles in the Vehicle Assembly Building. The fixture proofload tests, in tension and compression, a variety of ground support equipment, including slings, lifting beams and other critical lifting hardware that require periodic proofloading. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, launch simulation towers and a cryogenic system. Photo credit: NASA/Jim Grossmann
NASA Astrophysics Data System (ADS)
Fuxiao, Yu; Fang, Liu; Dazhi, Zhao; Toth, Laszlo S.
2014-08-01
Al-Fe alloys are attractive for applications at temperatures beyond those normally associated with the conventional aluminum alloys. Under proper solidification condition, a full eutectic microstructure can be generated in Al-Fe alloys at Fe concentration well in excess of the eutectic composition of 1.8 wt.% Fe. The microstructure in this case is characterized by the metastable regular eutectic Al-Al6Fe fibers of nano-scale in diameter, instead of the equilibrium eutectic Al-Al3Fe phase. In this study, the microstructure and mechanical properties of the Al-3Fe alloy with metastable Al6Fe particles deformed by equal channel angular extrusion were investigated. Severe plastic deformation results in a microstructure consisting of submicron equiaxed Al grains with a uniform distribution of submicron Al6Fe particles on the grain boundaries. The room temperature tensile properties of the alloy with this microstructure will be presented.
Quantum correlations from a room-temperature optomechanical cavity
NASA Astrophysics Data System (ADS)
Purdy, T. P.; Grutter, K. E.; Srinivasan, K.; Taylor, J. M.
2017-06-01
The act of position measurement alters the motion of an object being measured. This quantum measurement backaction is typically much smaller than the thermal motion of a room-temperature object and thus difficult to observe. By shining laser light through a nanomechanical beam, we measure the beam’s thermally driven vibrations and perturb its motion with optical force fluctuations at a level dictated by the Heisenberg measurement-disturbance uncertainty relation. We demonstrate a cross-correlation technique to distinguish optically driven motion from thermally driven motion, observing this quantum backaction signature up to room temperature. We use the scale of the quantum correlations, which is determined by fundamental constants, to gauge the size of thermal motion, demonstrating a path toward absolute thermometry with quantum mechanically calibrated ticks.
78 FR 54470 - National Committee on Vital and Health Statistics: Meeting Full Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-04
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Committee on Vital and Health Statistics: Meeting... Health Statistics (NCVHS); Full Committee Meeting. Time and Date: September 16, 2013 9:00 a.m.-2:45 p.m... Statistics, Centers for Disease Control and Prevention, 3311 Toledo Road, Room 2402, Hyattsville, Maryland...
Implementation of civionics in a second generation steel-free bridge deck
NASA Astrophysics Data System (ADS)
Klowak, Chad; Rivera, Evangeline; Mufti, Aftab
2005-05-01
As the design and construction of civil structures continue to evolve, it is becoming imperative that these structures be monitored for their health. In order to meet this need, the discipline of Civionics has emerged. Civionics is a new term coined from Civil-Electronics, which is derived from the application of electronics to civil structures. It is similar to the term Avionics, which is used in the aerospace industry. If structural health monitoring is to become part of civil structural engineering, it should include Civionics. It involves the application of electronics to civil structures and aims to assist engineers in realizing the full benefits of structural health monitoring (SHM). In past SHM field applications, the main reason for the failure of a sensor was not the installation of the sensor itself but the egress of the sensor cables. Often, the cables were not handled and protected correctly. For SHM to be successful, specifications must be written on the entire process, beginning with system design and concluding with data collection, interpretation, and management. Civionics specifications include the technical requirements for a SHM system which encompasses fibre optic sensors, cables, conduits, junction boxes and the control room. A specification for data collection and storage is currently being developed as well. In the spring of 2004 research engineers at the University of Manitoba constructed a full-scale second generation steel free bridge deck. The bridge deck is the first of its kind to fully incorporate a complete civionics structural health monitoring system to monitor the deck's behaviour during destructive testing. Throughout the construction of the bridge deck, the entire installation of the civionics system was carried out by research engineers simulating an actual implementation of such a system in a large scale construction environment. One major concern that consulting engineers have raised is the impact that a civionics system that uses conduit, junction boxes, and other electrical ancillary protection, will have when embedded and installed externally on full-scale infrastructure. The full-scale destructive testing of a second generation steel-free bridge deck using a civionics system designed and implemented following guidelines in a civioncs specification manual at the University of Manitoba will provide engineers with the information necessary to address the constructability and structural integrity issues. Civioncs combined with structural health monitoring will provide engineers with feedback necessary to aid in optimizing design techniques and understanding our infrastructures performance, behaviour and state of condition.
Innovative Designs for the Smart ICU.
Halpern, Neil A
2014-03-01
Successfully designing a new ICU requires clarity of vision and purpose and the recognition that the patient room is the core of the ICU experience for patients, staff, and visitors. The ICU can be conceptualized into three components: the patient room, central areas, and universal support services. Each patient room should be designed for single patient use and be similarly configured and equipped. The design of the room should focus upon functionality, ease of use, healing, safety, infection control, communications, and connectivity. All aspects of the room, including its infrastructure; zones for work, care, and visiting; environment, medical devices, and approaches to privacy; logistics; and waste management, are important elements in the design process. Since most medical devices used at the ICU bedside are really sophisticated computers, the ICU needs to be capable of supporting the full scope of medical informatics. The patient rooms, the central ICU areas (central stations, corridors, supply rooms, pharmacy, laboratory, staff lounge, visitor waiting room, on-call suite, conference rooms, and offices), and the universal support services (infection prevention, finishings and flooring, staff communications, signage and wayfinding, security, and fire and safety) work best when fully interwoven. This coordination helps establish efficient and safe patient throughput and care and fosters physical and social cohesiveness within the ICU. A balanced approach to centralized and decentralized monitoring and logistics also offers great flexibility. Synchronization of the universal support services in the ICU with the hospital's existing systems maintains unity of purpose and continuity across the enterprise and avoids unnecessary duplication of efforts. Copyright © 2014 The American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Evanoff, M G; Roehrig, H; Giffords, R S; Capp, M P; Rovinelli, R J; Hartmann, W H; Merritt, C
2001-06-01
This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.
Tao, Franklin Feng; Nguyen, Luan; Zhang, Shiran
2013-03-01
Here, we present the design of a new reactor-like high-temperature near ambient pressure scanning tunneling microscope (HT-NAP-STM) for catalysis studies. This HT-NAP-STM was designed for exploration of structures of catalyst surfaces at atomic scale during catalysis or under reaction conditions. In this HT-NAP-STM, the minimized reactor with a volume of reactant gases of ∼10 ml is thermally isolated from the STM room through a shielding dome installed between the reactor and STM room. An aperture on the dome was made to allow tip to approach to or retract from a catalyst surface in the reactor. This dome minimizes thermal diffusion from hot gas of the reactor to the STM room and thus remains STM head at a constant temperature near to room temperature, allowing observation of surface structures at atomic scale under reaction conditions or during catalysis with minimized thermal drift. The integrated quadrupole mass spectrometer can simultaneously measure products during visualization of surface structure of a catalyst. This synergy allows building an intrinsic correlation between surface structure and its catalytic performance. This correlation offers important insights for understanding of catalysis. Tests were done on graphite in ambient environment, Pt(111) in CO, graphene on Ru(0001) in UHV at high temperature and gaseous environment at high temperature. Atom-resolved surface structure of graphene on Ru(0001) at 500 K in a gaseous environment of 25 Torr was identified.
NASA Astrophysics Data System (ADS)
Lei, Xuefeng; Deng, Ying; Yin, Zhimin; Xu, Guofu
2014-06-01
2219-T87 aluminum alloy is widely used for fabricating liquid rocket propellant storage tank, due to its admirable cryogenic property. Welding is the dominant joining method in the manufacturing process of aerospace components. In this study, the tungsten inert gas welding and friction stir welding (FSW) characteristics of 4-mm-thick 2219-T87 alloy plate at room temperature (25 °C) and deep cryogenic temperature (-196 °C) were investigated by property measurements and microscopy methods. The studied 2219 base alloy exhibits a low strength plane anisotropy and excellent room temperature and cryogenic mechanical properties. The ultimate tensile strength values of TIG and FSW welding joints can reach 265 and 353 MPa at room temperature, and 342 and 438 MPa at -196 °C, respectively. The base metal consists of elongated deformed grains and many nano-scaled θ (Al2Cu) aging precipitates. Fusion zone and heat-affected zone (HAZ) of the TIG joint are characterized by coarsening dendritic grains and equiaxed recrystallized grains, respectively. The FSW-welded joint consists of the weld nugget zone, thermo-mechanically affected zone (TMAZ), and HAZ. In the weld nugget zone, a micro-scaled sub-grain structure is the main microstructure characteristic. The TMAZ and HAZ are both characterized by coarsened aging precipitates and elongated deformed grains. The excellent FSW welding properties are attributed to the preservation of the working structures and homogenous chemical compositions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, H.S.; Stone, C.M.
A pretest reference calculation for the Overtest for Simulated Defense High-Level Waste (DHLW) or Room B experiment is presented in this report. The overtest is one of several large-scale, in-situ experiments currently under construction near Carlsbad, New Mexico at the site of the Waste Isolation Pilot Plant (WIPP). Room B, a single isolated room in the underground salt formation, is to be subjected to a thermal load of approximately four times the areal heat output anticipated for a future repository with DHLW. The load will be supplied 3 years by canister heaters placed in the floor. Room B is heavilymore » instrumented for monitoring both temperature increases due to the thermal loading and deformations due to creep of the salt. Data from the experiment are not available at the present time, but the measurements will eventually be compared to the results presented to assess and improve thermal and mechanical modeling capabilities for the WIPP. The thermal/structural model used here represents the state of the art at the present time. A large number of plots are included since an appropriate result is presented for every Room B gauge location. 81 figs., 4 tabs.« less
NASA Astrophysics Data System (ADS)
Singh, Sukhdeep; Singh, Janpreet; Tripathi, S. K.
2018-05-01
Bismuth antimony telluride (Bi-Sb-Te) compounds have been investigated for the past many decades for thermoelectric (TE) power generation and cooling purpose. We synthesized this compound with a stoichiometry Bi1.2Sb0.8Te3 through melt cool technique and thin films of as synthesized material were deposited by thermal evaporation. The prime focus of the present work is to study the influence of annealing temperature on the room temperature (RT) power factor of thin films. Electrical conductivity and Seebeck coefficient were studied and power factors were calculated which showed a peak value at 323 K. The compounds performance is comparable to some very efficient Bi-Sb-Te reported stoichiometries at RT scale. The values observed show that material has an enormous potential for energy production at ambient temperature scales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, H.S.; Stone, C.M.
A pretest reference calculation for the 18-W/m/sup 2/ Mockup for Defense High-Level Waste (DHLW) or Room A experiment is presented in this report. The mockup is one of several large scale in situ experiments currently under construction near Carlsbad, New Mexico, at the site of the Waste Isolation Pilot Plant (WIPP). The 18-W/m/sup 2/ test is an in situ experiment developed to simulate closely the Reference Repository Conditions (RRC) for DHLW in salt. The test consists of three long, parallel rooms (A1, A2, A3) which are heated by canister heaters placed in the floor of each room. These heaters producemore » thermal loading which simulates an areal heat output of 18-W/m/sup 2/ for Room A2, which is the focus of the experiment. This load will be supplied for a period of three years. Rooms A1, A2, and A3 are heavily instrumented for monitoring both temperature increases due to the thermal loading and deformations due to creep of the salt. Data from the experiment are not available at the present time, but the measurements for Room A2 will eventually be compared to the results for Room A2 presented here to assess and improve thermal and mechanical modeling capabilities for the WIPP. The thermal/structural model used here represents the state-of-the-art at the present time. A large number of plots are included since an appropriate result is presented for every Room A2 gauge location. 55 refs., 70 figs., 4 tabs.« less
2013-04-01
and seven additional aircraft by fiscal year (FY) 16. As an interim solution, temporary trailers totaling 4,000 square feet (SF) are being used on a...hangar floor to accommodate office space and aircrew flight equipment workshop needs. However, the use of trailers comes at a direct cost to the...facility would have 18 classrooms, a gross motor room, a lobby with reception area, a conference room, administrative offices, a staff lounge, a full-service
Influence of perfusate temperature on nasal potential difference.
Bronsveld, Inez; Vermeulen, François; Sands, Dorotha; Leal, Teresinha; Leonard, Anissa; Melotti, Paola; Yaakov, Yasmin; de Nooijer, Roel; De Boeck, Kris; Sermet, Isabelle; Wilschanski, Michael; Middleton, Peter G
2013-08-01
Nasal potential difference (NPD) quantifies abnormal ion transport in cystic fibrosis. It has gained acceptance as an outcome measure for the investigation of new therapies. To quantify the effect of solution temperature on NPD, we first examined the effect of switching from room temperature (20-25°C) to warmed (32-37°C) solutions and vice versa during each perfusion step. Secondly, standard protocols were repeated at both temperatures in the same subjects. Changing solution temperature did not alter NPD during perfusion with Ringer's solution (<1 mV) (p>0.1). During perfusion with zero chloride solution, changing from room temperature to warmed solutions tended to decrease absolute NPD (i.e. it became less negative) by 0.9 mV (p>0.1); changing from warmed to room temperature increased NPD by 2.1 mV (p<0.05). During isoprenaline perfusion, changing from room temperature to warmed solutions increased NPD by 1.5 mV (p<0.01) and from warmed to room temperature decreased NPD by 1.4 mV (p<0.05). For full protocols at room temperature or warmed in the same subjects, mean values were similar (n = 24). During warmed perfusion, group results for total chloride response had a larger standard deviation. As this increased variability will probably decrease the power of trials, this study suggests that solutions at room temperature should be recommended for the measurement of NPD.
Quantifying object and material surface areas in residences
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodgson, Alfred T.; Ming, Katherine Y.; Singer, Brett C.
2005-01-05
The dynamic behavior of volatile organic compounds (VOCs) in indoor environments depends, in part, on sorptive interactions between VOCs in the gas phase and material surfaces. Since information on the types and quantities of interior material surfaces is not generally available, this pilot-scale study was conducted in occupied residences to develop and demonstrate a method for quantifying surface areas of objects and materials in rooms. Access to 33 rooms in nine residences consisting of bathrooms, bedroom/offices and common areas was solicited from among research group members living in the East San Francisco Bay Area. A systematic approach was implemented formore » measuring rooms and objects from 300 cm{sup 2} and larger. The ventilated air volumes of the rooms were estimated and surface area-to-volume ratios were calculated for objects and materials, each segregated into 20 or more categories. Total surface area-to-volume ratios also were determined for each room. The bathrooms had the highest total surface area-to-volume ratios. Bedrooms generally had higher ratios than common areas consisting of kitchens, living/dining rooms and transitional rooms. Total surface area-to-volume ratios for the 12 bedrooms ranged between 2.3 and 4.7 m{sup 2} m{sup -3}. The importance of individual objects and materials with respect to sorption will depend upon the sorption coefficients for the various VOC/materials combinations. When combined, the highly permeable material categories, which may contribute to significant interactions, had a median ratio of about 0.5 m{sup 2} m{sup -3} for all three types of rooms.« less
89. Photocopied August 1978. POWER HOUSE, GENERATOR ROOM, VIEW LOOKING ...
89. Photocopied August 1978. POWER HOUSE, GENERATOR ROOM, VIEW LOOKING EAST FROM ABOUT THE CENTER, FEBRUARY 26, 1918, AFTER MICHIGAN NORTHERN HAD BROUGHT THE GENERATOR INSTALLATION UP TO FULL CAPACITY. THE NARROW PANEL WESTINGHOUSE SWITCHBOARD INSTALLED IN 1916-17 IS AT THE UPPER RIGHT. THE NEW GENERAL ELECTRIC GENERATORS ARE BELOW THE GALLERY. NOTE THE D.C. EXCITER UNIT ON EXTENDED SHAFT ON THE UNIT IN THE FOREGROUND. A SIMILAR TYPE OF INSTALLATION WAS FOUND AT PENSTOCKS 45 THROUGH 48 AND 62 THROUGH 73. WHAT SEEM TO BE EXTENDED SHAFT UNITS IN THE BACKGROUND ARE MERELY THE OLD STANLEY ALTERNATORS BEFORE THEY HAD BEEN REMOVED FROM THE GENERATOR ROOM. (878) - Michigan Lake Superior Power Company, Portage Street, Sault Ste. Marie, Chippewa County, MI
Low-temperature operation of a Buck DC/DC converter
NASA Technical Reports Server (NTRS)
Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Myers, Ira T.
1995-01-01
Low-temperature (77 K) operation of a 42/28 V, 175 W, 50 kHz PWM Buck DC/DC converter designed with commercially available components is reported. Overall, the converter losses decreased at 77 K compared to room temperature operation. A full-load efficiency of 97 percent was recorded at liquid-nitrogen temperature, compared to 95.8 percent at room temperature. Power MOSFET operation improved significantly where as the output rectifier operation deteriorated at low-temperature. The performance of the output filter inductor and capacitor did not change significantly at 77 K compared to room temperature performance. It is possible to achieve high-density and high efficiency power conversion at low-temperatures due to improved electronic, electrical and thermal properties of materials.
NOAA Office of Exploration and Research > About OER > 2014 Funding
Room OER Symposium OER FY 2014 Federal Funding Opportunity: Closed Pre-Proposals were due on November 4 is the OER formal public announcement requesting pre-proposals and full proposals for fiscal year 2014. For the full FFO go to http://www.grants.gov/view-opportunity.html?oppId=243154. Pre-proposals
Room Temperature Monoclinic Phase in BaTiO3 Single Crystals
NASA Astrophysics Data System (ADS)
Denev, Sava; Kumar, Amit; Barnes, Andrew; Vlahos, Eftihia; Shepard, Gabriella; Gopalan, Venkatraman
2010-03-01
BaTiO3 is a well studied ferroelectric material for the last half century. It is well known to show phase transitions to tetragonal, orthorhombic and rhombohedral phases upon cooling. Yet, some old and some recent studies have argued that all these phases co-exist with a second phase with monoclinic distortion. Using optical second harmonic generation (SHG) at room temperature we directly present evidence for such monoclininc phase co-existing with tetragonal phase at room temperature. We observe domains with the expected tetragonal symmetry exhibiting 90^o and 180^o domain walls. However, at points of higher stress at the tips of the interpenetrating tetragonal domains we observe a well pronounced metastable ``staircase pattern'' with a micron-scale fine structure. Polarization studies show that this phase can be explained only by monoclinic symmetry. This phase is very sensitive to external perturbations such as temperature and fields, hence stabilizing this phase at room temperature could lead to large properties' tunability.
NASA Astrophysics Data System (ADS)
Zasimova, Marina; Ivanov, Nikolay
2018-05-01
The goal of the study is to validate Large Eddy Simulation (LES) data on mixing ventilation in an isothermal room at conditions of benchmark experiments by Hurnik et al. (2015). The focus is on the accuracy of the mean and rms velocity fields prediction in the quasi-free jet zone of the room with 3D jet supplied from a sidewall rectangular diffuser. Calculations were carried out using the ANSYS Fluent 16.2 software with an algebraic wall-modeled LES subgrid-scale model. CFD results on the mean velocity vector are compared with the Laser Doppler Anemometry data. The difference between the mean velocity vector and the mean air speed in the jet zone, both LES-computed, is presented and discussed.
MOCR activity during Day 6 of STS-3 mission
NASA Technical Reports Server (NTRS)
1982-01-01
Andrew A. Fullerton, the six-year-old son of STS-3 pilot C. Gordon Fullerton, watches a television monitor in the mission control center's viewing room (28802); Mrs. Marie J. Fullerton in the mission control center's viewing room. Other members of the STS-3 pilot's family are seated on each side of Mrs. Fullerton. His sister, Jeanne Dockham, is at left foreground; son Andrew A., at right foreground. Mr. and Mrs. E. G. Buettner, Mrs. Fullerton's parents, are seated at center, and beyond them is Mrs. Charles R. Fullerton, the astronaut's mother (28803); Mary Ann Austin seated at the remote manipulator sytem (RMS) console in the mission operations control room (MOCR) shares the scene with a representation of a 1/15-scale model of the Canadian-built remote manipulator system arm (28804).
Rösch, Petra; Harz, Michaela; Schmitt, Michael; Peschke, Klaus-Dieter; Ronneberger, Olaf; Burkhardt, Hans; Motzkus, Hans-Walter; Lankers, Markus; Hofer, Stefan; Thiele, Hans; Popp, Jürgen
2005-03-01
Microorganisms, such as bacteria, which might be present as contamination inside an industrial food or pharmaceutical clean room process need to be identified on short time scales in order to minimize possible health hazards as well as production downtimes causing financial deficits. Here we describe the first results of single-particle micro-Raman measurements in combination with a classification method, the so-called support vector machine technique, allowing for a fast, reliable, and nondestructive online identification method for single bacteria.
Rösch, Petra; Harz, Michaela; Schmitt, Michael; Peschke, Klaus-Dieter; Ronneberger, Olaf; Burkhardt, Hans; Motzkus, Hans-Walter; Lankers, Markus; Hofer, Stefan; Thiele, Hans; Popp, Jürgen
2005-01-01
Microorganisms, such as bacteria, which might be present as contamination inside an industrial food or pharmaceutical clean room process need to be identified on short time scales in order to minimize possible health hazards as well as production downtimes causing financial deficits. Here we describe the first results of single-particle micro-Raman measurements in combination with a classification method, the so-called support vector machine technique, allowing for a fast, reliable, and nondestructive online identification method for single bacteria. PMID:15746368
40 CFR 86.338-79 - Exhaust measurement accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... percent of full-scale chart deflection during the measurement of the emissions for each mode. The... percent of full-scale if the full-scale value is 155 ppm (or ppm C) or less. (2) Option. For CO analysis the analyzer's response may be less than 15 percent of full scale if the full-scale value is 5500 ppm...
Snoezelen Room and Childbirth Outcome: A Randomized Clinical Trial.
Jamshidi Manesh, Mansoureh; Kalati, Mahnaz; Hosseini, Fatemeh
2015-05-01
One of the strategies for a good outcome and pain free childbearing is to design the delivery room. The aim of this study was to evaluate the effects of snoezelen room on childbearing outcome such as pain intensity, duration of labor, and perinea status in nulliparous women. This study was a randomized controlled clinical trial consists of 100 childbearing women. They were randomly divided into 2 groups. The experimental group went to snoezelen room when their cervix dilation was 4 cm, while the control group went to physiologic delivery room with the same cervix dilation. The mean ± SD of VAS (Visual Analogue Scale) pain intensity of the experimental and control groups before the intervention were 5.1 ± 1.95 and 5.58 ± 1.62, respectively (P = 0.13). The mean ± SD of VAS pain intensity scores of the experimental and control groups after 3 hours spending in their assigned rooms were 5.26 ± 0.86 and 9.56 ± 1.48, respectively (P = 0.01). The mean ± SD of the first stage scores of the experimental and control groups were 6.95 ± 0.97 and 8.41 ± 0.67, respectively (P = 0.042). About 92% of participants' intervention vs. 66% of control participants had perinea laceration (P = 0.041). According to the findings of the present study, distracting senses in snoezelen room decreases mother's pain intensity, the length of labor, and incidence of episiotomy.
Snoezelen Room and Childbirth Outcome: A Randomized Clinical Trial
Jamshidi Manesh, Mansoureh; Kalati, Mahnaz; Hosseini, Fatemeh
2015-01-01
Background: One of the strategies for a good outcome and pain free childbearing is to design the delivery room. Objectives: The aim of this study was to evaluate the effects of snoezelen room on childbearing outcome such as pain intensity, duration of labor, and perinea status in nulliparous women. Patients and Methods: This study was a randomized controlled clinical trial consists of 100 childbearing women. They were randomly divided into 2 groups. The experimental group went to snoezelen room when their cervix dilation was 4 cm, while the control group went to physiologic delivery room with the same cervix dilation. Results: The mean ± SD of VAS (Visual Analogue Scale) pain intensity of the experimental and control groups before the intervention were 5.1 ± 1.95 and 5.58 ± 1.62, respectively (P = 0.13). The mean ± SD of VAS pain intensity scores of the experimental and control groups after 3 hours spending in their assigned rooms were 5.26 ± 0.86 and 9.56 ± 1.48, respectively (P = 0.01). The mean ± SD of the first stage scores of the experimental and control groups were 6.95 ± 0.97 and 8.41 ± 0.67, respectively (P = 0.042). About 92% of participants’ intervention vs. 66% of control participants had perinea laceration (P = 0.041). Conclusions: According to the findings of the present study, distracting senses in snoezelen room decreases mother’s pain intensity, the length of labor, and incidence of episiotomy. PMID:26082849
NASA Astrophysics Data System (ADS)
Wei, Wang; Chongchao, Pan; Yikai, Liang; Gang, Li
2017-11-01
With the rapid development of information technology, the scale of data center increases quickly, and the energy consumption of computer room also increases rapidly, among which, energy consumption of air conditioning cooling makes up a large proportion. How to apply new technology to reduce the energy consumption of the computer room becomes an important topic of energy saving in the current research. This paper study internet of things technology, and design a kind of green computer room environmental monitoring system. In the system, we can get the real-time environment data from the application of wireless sensor network technology, which will be showed in a creative way of three-dimensional effect. In the environment monitor, we can get the computer room assets view, temperature cloud view, humidity cloud view, microenvironment view and so on. Thus according to the condition of the microenvironment, we can adjust the air volume, temperature and humidity parameters of the air conditioning for the individual equipment cabinet to realize the precise air conditioning refrigeration. And this can reduce the energy consumption of air conditioning, as a result, the overall energy consumption of the green computer room will reduce greatly. At the same time, we apply this project in the computer center of Weihai, and after a year of test and running, we find that it took a good energy saving effect, which fully verified the effectiveness of this project on the energy conservation of the computer room.
Educational Gaming for Pharmacy Students - Design and Evaluation of a Diabetes-themed Escape Room.
Eukel, Heidi N; Frenzel, Jeanne E; Cernusca, Dan
2017-09-01
Objective. To design an educational game that will increase third-year professional pharmacy students' knowledge of diabetes mellitus disease management and to evaluate their perceived value of the game. Methods. Faculty members created an innovative educational game, the diabetes escape room. An authentic escape room gaming environment was established through the use of a locked room, an escape time limit, and game rules within which student teams completed complex puzzles focused on diabetes disease management. To evaluate the impact, students completed a pre-test and post-test to measure the knowledge they've gained and a perception survey to identify moderating factors that could help instructors improve the game's effectiveness and utility. Results. Students showed statistically significant increases in knowledge after completion of the game. A one-sample t -test indicated that students' mean perception was statistically significantly higher than the mean value of the evaluation scale. This statically significant result proved that this gaming act offers a potential instructional benefit beyond its novelty. Conclusion. The diabetes escape room proved to be a valuable educational game that increased students' knowledge of diabetes mellitus disease management and showed a positive perceived overall value by student participants.
Nurses in OR are more assertive than radiographers.
Johnson, L
1993-01-01
This study investigated two hypotheses: that there is a positive correlation between assertiveness and self-esteem, and that nurses rate lower than non-nurses on the constructs. A self-report survey incorporating scales for general assertiveness, situationally-specific assertiveness, global self-esteem and differentiated self-esteem was utilised. For the sample of 83 operating room nurses and 81 radiographers, correlations significant at the p < .001 level between the respective scales supported the first hypothesis. Analysis of variance yielded no significant differences between the two groups on either self-esteem measures or general assertiveness, with the nurses scoring significantly higher than radiographers on the situationally-specific assertiveness scale. Findings challenge the stereotype of the 'shrinking violet' nurse. Additional analysis revealed that the power component of differentiated self-esteem had a higher correlation with global self-esteem and with both assertiveness measures than any other component. Further, the operating room nurses were significantly more power-oriented than radiographers. The pre-eminence of power in the findings suggests that assertiveness and self-esteem are issues relating to the empowerment of nurses.
Kundhal, Pavi S; Grantcharov, Teodor P
2009-03-01
This study was conducted to validate the role of virtual reality computer simulation as an objective method for assessing laparoscopic technical skills. The authors aimed to investigate whether performance in the operating room, assessed using a modified Objective Structured Assessment of Technical Skill (OSATS), correlated with the performance parameters registered by a virtual reality laparoscopic trainer (LapSim). The study enrolled 10 surgical residents (3 females) with a median of 5.5 years (range, 2-6 years) since graduation who had similar limited experience in laparoscopic surgery (median, 5; range, 1-16 laparoscopic cholecystectomies). All the participants performed three repetitions of seven basic skills tasks on the LapSim laparoscopic trainer and one laparoscopic cholecystectomy in the operating room. The operating room procedure was video recorded and blindly assessed by two independent observers using a modified OSATS rating scale. Assessment in the operating room was based on three parameters: time used, error score, and economy of motion score. During the tasks on the LapSim, time, error (tissue damage and millimeters of tissue damage [tasks 2-6], error score [incomplete target areas, badly placed clips, and dropped clips [task 7]), and economy of movement parameters (path length and angular path) were registered. The correlation between time, economy, and error parameters during the simulated tasks and the operating room procedure was statistically assessed using Spearman's test. Significant correlations were demonstrated between the time used to complete the operating room procedure and time used for task 7 (r (s) = 0.74; p = 0.015). The error score demonstrated during the laparoscopic cholecystectomy correlated well with the tissue damage in three of the seven tasks (p < 0.05), the millimeters of tissue damage during two of the tasks, and the error score in task 7 (r (s) = 0.67; p = 0.034). Furthermore, statistically significant correlations were observed between the economy of motion score from the operative procedure and LapSim's economy parameters (path length and angular path in six of the tasks) (p < 0.05). The current study demonstrated significant correlations between operative performance in the operating room (assessed using a well-validated rating scale) and psychomotor performance in virtual environment assessed by a computer simulator. This provides strong evidence for the validity of the simulator system as an objective tool for assessing laparoscopic skills. Virtual reality simulation can be used in practice to assess technical skills relevant for minimally invasive surgery.
Chen, Connie E; Chen, Christopher T; Hu, Jia; Mehrotra, Ateev
2017-02-17
Walk-in clinics are growing in popularity around the world as a substitute for traditional medical care delivered in physician offices and emergency rooms, but their clinical efficacy is unclear. To assess the quality of care and patient satisfaction of walk-in clinics compared to that of traditional physician offices and emergency rooms for people who present with basic medical complaints for either acute or chronic issues. We searched CENTRAL, MEDLINE, Embase, six other databases, and two trials registers on 22 March 2016 together with reference checking, citation searching, and contact with study authors to identify additional studies. We applied no restrictions on language, publication type, or publication year. Study design: randomized trials, non-randomized trials, and controlled before-after studies. standalone physical clinics not requiring advance appointments or registration, that provided basic medical care without expectation of follow-up. Comparisons: traditional primary care practices or emergency rooms. We used standard methodological procedures expected by Cochrane and the Cochrane Effective Practice and Organisation of Care (EPOC) Group. The literature search identified 6587 citations, of which we considered 65 to be potentially relevant. We reviewed the abstracts of all 65 potentially relevant studies and retrieved the full texts of 12 articles thought to fit our study criteria. However, following independent author assessment of the full texts, we excluded all 12 articles. Controlled trial evidence about the mortality, morbidity, quality of care, and patient satisfaction of walk-in clinics is currently not available.
Polgár, Patricia; Farkas, Márta; Nagy, Orsolya; Kelemen, Oguz; Réthelyi, János; Bitter, István; Myers, Catherine E; Gluck, Mark A; Kéri, Szabolcs
2008-02-01
Recent meta-analytic evidence suggests that clinical neuropsychological methods are not likely to uncover circumscribed cognitive impairments in the deficit syndrome of schizophrenia. To overcome this issue, we adapted a cognitive neuroscience perspective and used a new "chaining" habit learning task. Participants were requested to navigate a cartoon character through a sequence of 4 rooms by learning to choose the open door from 3 colored doors in each room. The aim of the game was to learn the full sequence of rooms until the character reached the outside. In the training phase, each stimulus leading to reward (open door in each room) was trained via feedback until the complete sequence was learned. In the probe phase, the context of rewarded stimuli was manipulated: in a given room, in addition to the correct door of that room, there also appeared a door which was open in another room. Whereas the training phase is dominantly related to basal ganglia circuits, the context-dependent probe phase requires intact medial-temporal lobe functioning. Results revealed that deficit and non-deficit patients were similarly impaired on the probe phase compared with controls. However, the training phase was only compromised in deficit patients. More severe negative symptoms were associated with more errors on the training phase. Executive functions were unrelated to performance on the "chaining" task. These results indicate that the deficit syndrome is associated with prominently impaired stimulus-response reinforcement learning, which may indicate abnormal functioning of basal ganglia circuits.
12 CFR 1807.902 - Data collection and reporting.
Code of Federal Regulations, 2012 CFR
2012-01-01
... representatives, shall have full and free access to the Awardee's offices and facilities and all books, documents... Street, NW., Room 2200, New Executive Office Building, Washington, DC 20503 or on the Internet (http...
12 CFR 1807.902 - Data collection and reporting.
Code of Federal Regulations, 2014 CFR
2014-01-01
... representatives, shall have full and free access to the Awardee's offices and facilities and all books, documents... Street, NW., Room 2200, New Executive Office Building, Washington, DC 20503 or on the Internet (http...
12 CFR 1807.902 - Data collection and reporting.
Code of Federal Regulations, 2011 CFR
2011-01-01
... representatives, shall have full and free access to the Awardee's offices and facilities and all books, documents... Street, NW., Room 2200, New Executive Office Building, Washington, DC 20503 or on the Internet (http...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
... administration space. Food and beverage facilities would include two full service restaurants, a drive-in restaurant, a buffet, a coffee shop, three service bars, and a lounge. The hotel tower would have approximately 100 rooms and a full-service restaurant. Both the gaming facility and the hotel would be open 24...
Bonrath, Esther M; Dedy, Nicolas J; Gordon, Lauren E; Grantcharov, Teodor P
2015-08-01
The aim of the study was to determine whether individualized coaching improved surgical technical skill in the operating room to a higher degree than current residency training. Clinical training in the operating room is a valuable opportunity for surgeons to acquire skill and knowledge; however, it often remains underutilized. Coaching has been successfully used in various industries to enhance performance, but its role in surgery has been insufficiently investigated. This randomized controlled trial was conducted at one surgical training program. Trainees undergoing a minimally invasive surgery rotation were randomized to either conventional training (CT) or comprehensive surgical coaching (CSC). CT included ward and operating room duties, and regular departmental teaching sessions. CSC comprised performance analysis, debriefing, feedback, and behavior modeling. Primary outcome measures were technical performance as measured on global and procedure-specific rating scales, and surgical safety parameters, measured by error count. Operative performance was assessed by blinded video analysis of the first and last cases recorded by the participants during their rotation. Twenty residents were randomized and 18 completed the study. At posttraining the CSC group (n = 9) scored significantly higher on a procedure-specific skill scale compared with the CT group (n = 9) [median, 3.90 (interquartile range, 3.68-4.30) vs 3.60 (2.98-3.70), P = 0.017], and made fewer technical errors [10 (7-13) vs 18 (13-21), P = 0.003]. Significant within-group improvements for all skill metrics were only noted in the CSC group. Comprehensive surgical coaching enhances surgical training and results in skill acquisition superior to conventional training.
NASA Astrophysics Data System (ADS)
Kesler, Michael Steiner
Titanium aluminides are of interest as a candidate material for aerospace turbine applications due to their high strength to weight ratio. gamma-TiAl + alpha2-Ti3Al alloys have recently been incorporated in the low pressure turbine region but their loss of strength near 750C limits their high temperature use. Additions of Nb have been shown to have several beneficial effects in gamma+alpha2 alloys, including enhancements in strength and ductility of the gamma-phase, along with the stabilization of the cubic BCC beta-phase at forging temperatures allowing for thermomechanical processing. In the ternary Ti-Al-Nb system at high Nb-contents above approximately 10at%, there exists a two-phase gamma-TiAl + sigma-Nb2Al region at and above current service temperature for the target application. Limited research has been conducted on the mechanical properties of alloys with this microstructure, though they have demonstrated excellent high temperature strength, superior to that of gamma+alpha2 alloys. Because the sigma-phase does not deform at room temperature, high volume fractions of this phase result in poor toughness and no tensile elongation. Controlling the microstructural morphology by disconnecting the brittle matrix through heat treatments has improved the toughness at room temperature. In this study, attempts to further improve the mechanical properties of these alloys were undertaken by reducing the volume fraction of the sigma-phase and controlling the scale of the gamma+sigma microstructure through the aging of a meta-stable parent phase, the beta- phase, that was quenched-in to room temperature. Additions of beta-stabilizing elements, Cr and Mo, were needed in order to quench-in the beta-phase. The room temperature mechanical properties were evaluated by compression, Vickers' indentation and single edge notch bend tests at room temperature. The formation of the large gamma-laths at prior beta- phase grain boundaries was found to be detrimental to ductility due to strain localization in this coarsened region of the microstructure. Furthermore, samples aged from beta- phase single crystals proved to have excellent combinations of strength and ductility under compression. In the single crystals, microcracking did not develop until much larger plastic strains were reached. Lowering the volume fraction of the sigma-phase proved to enhance the fracture toughness in these alloys. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)
Augmented reality assisted surgery: a urologic training tool
Dickey, Ryan M; Srikishen, Neel; Lipshultz, Larry I; Spiess, Philippe E; Carrion, Rafael E; Hakky, Tariq S
2016-01-01
Augmented reality is widely used in aeronautics and is a developing concept within surgery. In this pilot study, we developed an application for use on Google Glass® optical head-mounted display to train urology residents in how to place an inflatable penile prosthesis. We use the phrase Augmented Reality Assisted Surgery to describe this novel application of augmented reality in the setting of surgery. The application demonstrates the steps of the surgical procedure of inflatable penile prosthesis placement. It also contains software that allows for detection of interest points using a camera feed from the optical head-mounted display to enable faculty to interact with residents during placement of the penile prosthesis. Urology trainees and faculty who volunteered to take part in the study were given time to experience the technology in the operative or perioperative setting and asked to complete a feedback survey. From 30 total participants using a 10-point scale, educational usefulness was rated 8.6, ease of navigation was rated 7.6, likelihood to use was rated 7.4, and distraction in operating room was rated 4.9. When stratified between trainees and faculty, trainees found the technology more educationally useful, and less distracting. Overall, 81% of the participants want this technology in their residency program, and 93% see this technology in the operating room in the future. Further development of this technology is warranted before full release, and further studies are necessary to better characterize the effectiveness of Augmented Reality Assisted Surgery in urologic surgical training. PMID:26620455
High-Temperature Modal Survey of a Hot-Structure Control Surface
NASA Technical Reports Server (NTRS)
Spivey, Natalie Dawn
2010-01-01
Ground vibration tests or modal surveys are routinely conducted for supporting flutter analysis for subsonic and supersonic vehicles; however, for hypersonic vehicle applications, thermoelastic vibration testing techniques are not well established and are not routinely performed for supporting hypersonic flutter analysis. New high-temperature material systems, fabrication technologies and high-temperature sensors expand the opportunities to develop advanced techniques for performing ground vibration tests at elevated temperatures. High-temperature materials have the unique property of increasing in stiffness when heated. When these materials are incorporated into a hot-structure, which includes metallic components that decrease in stiffness with increasing temperature, the interaction between the two materials systems needs to be understood because that interaction could ultimately affect the hypersonic flutter analysis. Performing a high-temperature modal survey will expand the research database for hypersonics and will help build upon the understanding of the dual material interaction. This paper will discuss the vibration testing of the Carbon-Silicon Carbide Ruddervator Subcomponent Test Article which is a truncated version of the full-scale X-37 hot-structure control surface. In order to define the modal characteristics of the test article during the elevated-temperature modal survey, two series of room-temperature modal test configurations had to be performed. The room-temperature test series included one with the test article suspended from a bungee cord (free-free) and the second with it mounted on the strongback (fixed boundary condition) in NASA Dryden's Flight Loads Lab large nitrogen test chamber.
Augmented reality assisted surgery: a urologic training tool.
Dickey, Ryan M; Srikishen, Neel; Lipshultz, Larry I; Spiess, Philippe E; Carrion, Rafael E; Hakky, Tariq S
2016-01-01
Augmented reality is widely used in aeronautics and is a developing concept within surgery. In this pilot study, we developed an application for use on Google Glass ® optical head-mounted display to train urology residents in how to place an inflatable penile prosthesis. We use the phrase Augmented Reality Assisted Surgery to describe this novel application of augmented reality in the setting of surgery. The application demonstrates the steps of the surgical procedure of inflatable penile prosthesis placement. It also contains software that allows for detection of interest points using a camera feed from the optical head-mounted display to enable faculty to interact with residents during placement of the penile prosthesis. Urology trainees and faculty who volunteered to take part in the study were given time to experience the technology in the operative or perioperative setting and asked to complete a feedback survey. From 30 total participants using a 10-point scale, educational usefulness was rated 8.6, ease of navigation was rated 7.6, likelihood to use was rated 7.4, and distraction in operating room was rated 4.9. When stratified between trainees and faculty, trainees found the technology more educationally useful, and less distracting. Overall, 81% of the participants want this technology in their residency program, and 93% see this technology in the operating room in the future. Further development of this technology is warranted before full release, and further studies are necessary to better characterize the effectiveness of Augmented Reality Assisted Surgery in urologic surgical training.
39. Photocopy of scale drawing (from Station 'L' office files, ...
39. Photocopy of scale drawing (from Station 'L' office files, Portland, Oregon) Portland General Electric in house drawing, 5/12/1927 SECTION (TOP) AND ELEVATION (BOTTOM) OF BOILER #9 WHICH IS LOCATED IN THE H.P. BOILER ROOM BUILDING L4, DIAGRAM OF THE GENERAL LAYOUT AND STEAM PIPING OF THE BOILER - Portland General Electric Company, Station "L", 1841 Southeast Water Street, Portland, Multnomah County, OR
Non-local electrical spin injection and detection in germanium at room temperature
NASA Astrophysics Data System (ADS)
Rortais, F.; Vergnaud, C.; Marty, A.; Vila, L.; Attané, J.-P.; Widiez, J.; Zucchetti, C.; Bottegoni, F.; Jaffrès, H.; George, J.-M.; Jamet, M.
2017-10-01
Non-local carrier injection/detection schemes lie at the very foundation of information manipulation in integrated systems. This paradigm consists in controlling with an external signal the channel where charge carriers flow between a "source" and a well separated "drain." The next generation electronics may operate on the spin of carriers in addition to their charge and germanium appears as the best hosting material to develop such a platform for its compatibility with mainstream silicon technology and the predicted long electron spin lifetime at room temperature. In this letter, we demonstrate injection of pure spin currents (i.e., with no associated transport of electric charges) in germanium, combined with non-local spin detection at 10 K and room temperature. For this purpose, we used a lateral spin valve with epitaxially grown magnetic tunnel junctions as spin injector and spin detector. The non-local magnetoresistance signal is clearly visible and reaches ≈15 mΩ at room temperature. The electron spin lifetime and diffusion length are 500 ps and 1 μm, respectively, the spin injection efficiency being as high as 27%. This result paves the way for the realization of full germanium spintronic devices at room temperature.
Research on OpenStack of open source cloud computing in colleges and universities’ computer room
NASA Astrophysics Data System (ADS)
Wang, Lei; Zhang, Dandan
2017-06-01
In recent years, the cloud computing technology has a rapid development, especially open source cloud computing. Open source cloud computing has attracted a large number of user groups by the advantages of open source and low cost, have now become a large-scale promotion and application. In this paper, firstly we briefly introduced the main functions and architecture of the open source cloud computing OpenStack tools, and then discussed deeply the core problems of computer labs in colleges and universities. Combining with this research, it is not that the specific application and deployment of university computer rooms with OpenStack tool. The experimental results show that the application of OpenStack tool can efficiently and conveniently deploy cloud of university computer room, and its performance is stable and the functional value is good.
48 CFR 34.005-5 - Full-scale development contracts.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Full-scale development... SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.005-5 Full-scale development contracts. Whenever practicable, the full-scale development contracts should provide for the contractors to...
48 CFR 34.005-5 - Full-scale development contracts.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Full-scale development... SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.005-5 Full-scale development contracts. Whenever practicable, the full-scale development contracts should provide for the contractors to...
Impact of animal-assisted therapy for outpatients with fibromyalgia.
Marcus, Dawn A; Bernstein, Cheryl D; Constantin, Janet M; Kunkel, Frank A; Breuer, Paula; Hanlon, Raymond B
2013-01-01
Animal-assisted therapy using dogs trained to be calm and provide comfort to strangers has been used as a complementary therapy for a range of medical conditions. This study was designed to evaluate the effects of brief therapy dog visits for fibromyalgia patients attending a tertiary outpatient pain management facility compared with time spent in a waiting room. Open label with waiting room control. Tertiary care, university-based, outpatient pain management clinic. A convenience sample of fibromyalgia patients was obtained through advertisements posted in the clinic. Participants were able to spend clinic waiting time with a certified therapy dog instead of waiting in the outpatient waiting area. When the therapy dog was not available, individuals remained in the waiting area. OUTCOME MEASURES.: Self-reported pain, fatigue, and emotional distress were recorded using 11-point numeric rating scales before and after the therapy dog visit or waiting room time. Data were evaluated from 106 therapy dog visits and 49 waiting room controls, with no significant between-group demographic differences in participants. Average intervention duration was 12 minutes for the therapy dog visit and 17 minutes for the waiting room control. Significant improvements were reported for pain, mood, and other measures of distress among patients after the therapy dog visit, but not the waiting room control. Clinically meaningful pain relief (≥2 points pain severity reduction) occurred in 34% after the therapy dog visit and 4% in the waiting room control. Outcome was not affected by the presence of comorbid anxiety or depression. Brief therapy dog visits may provide a valuable complementary therapy for fibromyalgia outpatients. Wiley Periodicals, Inc.
Kanda, K; Tsuchiya, J; Seto, M; Ohnaka, T; Tochihara, Y
1995-06-01
Thermal conditions in the bathroom and physiological responses were examined during winter and summer. The subjects were 22 male and 20 female elderly people, between 65 and 88 years old living in 25 houses in Gunma Prefecture, Japan. Heart rate, blood pressure, skin temperature and thermal sensation were measured during bathing. Changes in thermal sensation due to bathing were assessed in the living room and dressing room on a 9-point scale. Then they were asked about the purposes of bathing and the facilities of bathroom and dressing room. The results are summarized as follows: 1. The purpose of bathing in winter was to warm up for more than 80% of the subjects. In summer, all subjects felt refreshed by bathing. Eighty-five percent of the subjects took a bath every other day in both seasons. 2. Fifty-two percent of the bathrooms had no ventilating fans and 32% had no exclusive dressing rooms. 3. The average room temperature in the dressing rooms was 13-14 degrees C in winter. Thermal sensation was 'cool', 'slightly cold' or 'cold' for more than two-thirds of the subjects when they were partially nude, and there were no heaters in most dressing rooms. 4. The heart rate increased steadily, and reached a maximum value in a partially dressed condition in both seasons. 5. In winter, a marked increase of systolic blood pressure was observed in the partially nude condition. There was a significant difference between the before bathing condition and partially nude condition in winter.(ABSTRACT TRUNCATED AT 250 WORDS)
Effect of National Football League games on small animal emergency room caseload.
Rozanski, Elizabeth A; Rondeau, Mark P; Shaw, Scott P; Rush, John E
2009-07-01
To evaluate whether games of popular professional football teams have an effect on small animal emergency room caseload and percentage of dogs and cats that subsequently are hospitalized, are euthanatized, or die following admission to veterinary emergency rooms located within a dedicated fan base. Prospective study. 818 dogs and cats admitted to the emergency room. During the 2007 New England Patriots (NEP) football season, small animal emergency room caseload was recorded for Sunday (4-hour blocks, 8:00 AM until 12:00 midnight) and Monday night (7:00 PM to 11:00 PM). Number of dogs and cats that subsequently were hospitalized, died, or were euthanatized was recorded. Mean game importance rating (GIR) was determined for NEP games (scale, 1 [mild] to 3 [great]). Percentage of dogs and cats admitted from 12:00 noon to 4:00 PM on Sundays during NEP games (mean GIR, 1.7) versus non-NEP games was not different. Mean +/- SD percentage of dogs and cats admitted from 4:00 PM to 8:00 PM on Sundays during NEP games (mean GIR, 2.4) versus non-NEP games was significantly different (18 +/- 5% and 25 +/- 7% of daily caseload, respectively). Percentage of dogs and cats admitted from 8:00 PM to 12:00 midnight on Sundays during NEP games (mean GIR, 2.1) versus non-NEP games was not different. Game type (NEP vs non-NEP) during emergency room admission did not influence whether dogs and cats subsequently were hospitalized, died, or were euthanatized. Professional sporting events may influence veterinary emergency room caseloads.
STS-134 Orbit 2 flight controllers on consoles
2011-05-17
JSC2011-E-045472 (17 May 2011) --- A scale model of HM Bark Endeavour, namesake for the space shuttle currently making its final flight, adorns a console in the space shuttle flight control room in Mission Control in Houston. This model was first displayed in 1992 in the old shuttle control room during STS-49, the inaugural flight of the shuttle Endeavour. It was built by Dan Willett of JSC's Information Resources Directorate. The original sailing ship Endeavour was commanded by Lt. James Cook on a scientific voyage to the South Pacific, Australia and New Zealand from 1768 to 1771. Photo credit: NASA
Kim, Jae-Kwan; Kim, Jun Young; Yoon, Jae-Sik; Lee, Ji-Myon
2013-10-01
The formation of nanometer-scale (ns)-Si dots and clusters on p-GaN layers has been studied by controlling the early stage of growth during plasma-enhanced chemical vapor deposition (PECVD) at room temperature. We found that ns-Si dots and clusters formed on the p-GaN surface, indicating that growth was the Volmer-Weber mode. The deposition parameters such as radio frequency (RF) power and processing time mainly influenced the size of the ns-Si dots (40 nm-160 nm) and the density of the ns-Si dot clusters.
Indoor Spatial Updating With Impaired Vision
Legge, Gordon E.; Granquist, Christina; Baek, Yihwa; Gage, Rachel
2016-01-01
Purpose Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Methods Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. Results The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. Conclusions People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient. PMID:27978556
Indoor Spatial Updating With Impaired Vision.
Legge, Gordon E; Granquist, Christina; Baek, Yihwa; Gage, Rachel
2016-12-01
Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient.
Effect of breast-feeding on pain relief during infant immunization injections.
Abdel Razek, Aida; Az El-Dein, Nagwa
2009-04-01
Using a quasi-experimental design, this study was conducted in two maternal & child health centres in Jordan to examine the effects of breast-feeding on pain relief during neonatal immunization injections. Inclusion criteria were first year of age, breast-fed and no concurrent illness. Infants were divided into two groups (of 60 infants for each). One is intervention group: mothers were taken to a private room, seated and reclined on a comfortable chair with their infants awake in their arms, without cloth and with clean diapers. The mothers cradled their infants during breast-feeding to maintain full-body skin-to-skin contact during immunization injections. The other is control group: infants were observed during routine immunization in maternal & child health centres. Pain responses of infants during and after immunization were assessed by using Facial Pain Rating Scale and Neonatal/Infant Pain Scale (NIPS), before, during and after the procedure. Infants' heart rates and duration of crying for both groups were calculated. Findings revealed that the crying time was shorter in intervention (breast-fed) group than in the control group with a statistically significant difference in the duration of crying during and after immunization. We concluded that, breast-feeding and skin-to-skin contact significantly reduced crying in infants receiving immunization.
Choi, Young-Ji; Bradley, John S; Jeong, Dae-Up
2015-01-01
This paper examines how the individual variations of chair type, row spacing, as well as the presence of occupants and carpet, combine to influence the absorption characteristics of theater chairs as a function of sample perimeter-to-area (P/A) ratios. Scale models were used to measure the interactive effects of the four test variables on the chair absorption characteristics, avoiding the practical difficulties of full scale measurements. All of the test variables led to effects that could lead to important changes to auditorium acoustics conditions. At mid and higher frequencies, the various effects can usually be explained as due to, more or less, porous absorbing material. In the 125 and 250 Hz octave bands, the major changes were attributed to resonant absorbing mechanisms. The results indicate that for accurate predictions of the effective absorption of the chairs in an auditorium, one should use the P/A method and reverberation chamber tests of the chair absorption coefficients to predict the absorption coefficients of each block of chairs and use these results as input in a room acoustics computer model of the auditorium. The application of these results to auditorium acoustics design is described, more approximate approaches are considered, and relations to existing methods are discussed.
Altitude Wind Tunnel Control Room
1945-05-21
Researchers at the National Advisory Committee for Aeronautics (NACA) Aircraft Engine Research Laboratory monitor a ramjet's performance in the Altitude Wind Tunnel from the control room. The soundproof control room was just a few feet from the tunnel’s 20-foot-diameter test section. In the control room, the operators could control all aspects of the tunnel’s operation, including the air density, temperature, and speed. They also operated the engine or test article in the test section by controlling the angle-of-attack, speed, power, and other parameters. The men in this photograph are monitoring the engine’s thrust and lift. A NACA-designed 20-inch-diameter ramjet was installed in the tunnel in May 1945. Thrust figures from these runs were compared with drag data from tests of scale models in small supersonic tunnels to verify the ramjet’s feasibility. The tunnel was used to analyze the ramjet’s overall performance up to altitudes of 47,000 feet and speeds to Mach 1.84. The researchers found that an increase in altitude caused a reduction in the engine’s horsepower and identified optimal flameholder configurations.
4. Close view of the logs joining of the north ...
4. Close view of the logs joining of the north and south rooms, with scale (Note: hole with remains of peg SITU as seen in the east cabin) - The Hermitage, Alfred's Cabin, 4580 Rachel's Lane, Hermitage, Davidson County, TN
Pattern of emergency room mortality among road traffic crash victims.
Babalola, Oladimeji Ranti; Oluwadiya, Kehinde; Vrgoč, Goran; Akpati, Ugochukwu; Sindik, Joško; Čoklo, Miran; Marinović, Marin; Bakota, Bore
2015-11-01
Road traffic injuries are a major cause of death in the emergency room. The goal of this study was to highlight the demographic pattern of road traffic-related deaths in the accident and emergency room of a regional trauma centre. This was a 5-year retrospective study in which road traffic-related cases of emergency room mortality between June 2009 and June 2014 were reviewed. A total of 33 road traffic crash-related deaths occurred during this period with a male-to-female ratio of 2.3:1. Most of these patients were pedestrians with severe injuries involving two or more Abbreviated Injury Scale (AIS) coded regions. The mean time between injury and presentation in the first trauma facility was 112.1 (±55.4)min, and between presentation in the emergency room and death was 410 (±645)min. Mangled lower extremity, bilateral long bone lower limb fractures, pelvic injuries, blunt injuries to the chest and abdomen, and cranial fossae fractures were the common injury pattern. Median ISS and NISS in these patients were 22 (interquartile range [IQR]=11) and 25 (IQR=17), respectively. Severe injuries, delayed presentation, multiple referrals and delayed resuscitative measures contribute to road traffic crash-related mortality. Copyright © 2015 Elsevier Ltd. All rights reserved.
Patients' Experience of Winter Depression and Light Room Treatment
2017-01-01
Background. There is a need for more knowledge on the effects of light room treatment in patients with seasonal affective disorder and to explore patients' subjective experience of the disease and the treatment. Methods. This was a descriptive and explorative study applying qualitative content analysis. A purposeful sample of 18 psychiatric outpatients with a major depressive disorder with a seasonal pattern and a pretreatment score ≥12 on the 9-item Montgomery-Åsberg Depression self-rating scale was included (10 women and 8 men, aged 24–65 years). All patients had completed light room treatment (≥7/10 consecutive weekdays). Data was collected two weeks after treatment using a semistructured interview guide. Results. Patients described a clear seasonal pattern and a profound struggle to adapt to seasonal changes during the winter, including deterioration in sleep, daily rhythms, energy level, mood, activity, and cognitive functioning. Everyday life was affected with reduced work capacity, social withdrawal, and disturbed relations with family and friends. The light room treatment resulted in a radical and rapid improvement in all the major symptoms with only mild and transient side effects. Discussion. The results indicate that light room treatment is essential for some patients' ability to cope with seasonal affective disorder. PMID:28293623
75 FR 80013 - Radio Broadcasting Services; Jewett, TX
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-21
..., 2010, and released December 3, 2010. The full text of this Commission decision is available for... 12th Street, SW., Room CY-A257, Washington, DC 20554. The complete text of this decision also may be...
76 FR 43933 - Radio Broadcasting Services; Markham, TX
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-22
... released June 28, 2011. The full text of this Commission decision is available for inspection and copying...., Room CY-A257, Washington, DC 20554. The complete text of this decision also may be purchased from the...
Benchmark Testing of the Largest Titanium Aluminide Sheet Subelement Conducted
NASA Technical Reports Server (NTRS)
Bartolotta, Paul A.; Krause, David L.
2000-01-01
To evaluate wrought titanium aluminide (gamma TiAl) as a viable candidate material for the High-Speed Civil Transport (HSCT) exhaust nozzle, an international team led by the NASA Glenn Research Center at Lewis Field successfully fabricated and tested the largest gamma TiAl sheet structure ever manufactured. The gamma TiAl sheet structure, a 56-percent subscale divergent flap subelement, was fabricated for benchmark testing in three-point bending. Overall, the subelement was 84-cm (33-in.) long by 13-cm (5-in.) wide by 8-cm (3-in.) deep. Incorporated into the subelement were features that might be used in the fabrication of a full-scale divergent flap. These features include the use of: (1) gamma TiAl shear clips to join together sections of corrugations, (2) multiple gamma TiAl face sheets, (3) double hot-formed gamma TiAl corrugations, and (4) brazed joints. The structural integrity of the gamma TiAl sheet subelement was evaluated by conducting a room-temperature three-point static bend test.
Properties and rapid sintering of a nanostructured tetragonal zirconia composites
NASA Astrophysics Data System (ADS)
Shon, In-Jin; Yoon, Jin-Kook; Hong, Kyung-Tae
2017-09-01
4YSZ is generally used as oxygen sensors, fuel cells, thermal barrier and hip and knee joint replacements as a result of these excellent properties with its high biocompatibility, low density, good resistance against corrosion, high ionic conductivity, hard phase and melting point. However, 4YTZ with coarse grain has low resistance to wear and abrasion because of low hardness and low fracture toughness at room temperature. The fracture toughness and hardness of a 4YTZ can be improved by forming nanostructured composites and addition of a second hard phase. In this study, nanostuctured 4YTZ-graphene composites with nearly full density were achieved using high-frequency induction heated sintering for one min at a pressure of 80 MPa. The rapid consolidation and addition of graphene to 4YTZ retained the nano-scale structure of the ceramic by inhibiting grain growth. The grain size of 4YTZ was reduced remarkably by the addition of graphene and the addition of graphene to 4YTZ greatly improved the fracture toughness without decrease of hardness.
Overview of the ATLAS Insertable B-Layer (IBL) Project
NASA Astrophysics Data System (ADS)
Kagan, M. A.
2014-06-01
The first upgrade for the Pixel Detector will be a new pixel layer which is currently under construction and will be installed during the first shutdown of the LHC machine, in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe. Two different silicon sensor technologies, planar n-in-n and 3D, will be used, connected with the new generation 130nm IBM CMOS FE-I4 readout chip via solder bump-bonds. A production quality control test bench was set up in the ATLAS inner detector assembly clean room to verify and rate the performance of the detector elements before integration around the beam-pipe. An overview of the IBL project, of the module design, the qualification for these sensor technologies, the integration quality control setups and recent results in the construction of this full scale new concept detector is discussed.
2010-10-21
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller
2010-10-21
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller
2010-10-21
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller
2010-10-21
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller
Zhu, Yuanyuan; Browning, Nigel D.
2017-05-24
As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelasticmore » scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. Furthermore, we demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.« less
Accurate double many-body expansion potential energy surface for the 2(1)A' state of N2O.
Li, Jing; Varandas, António J C
2014-08-28
An accurate double many-body expansion potential energy surface is reported for the 2(1)A' state of N2O. The new double many-body expansion (DMBE) form has been fitted to a wealth of ab initio points that have been calculated at the multi-reference configuration interaction level using the full-valence-complete-active-space wave function as reference and the cc-pVQZ basis set, and subsequently corrected semiempirically via double many-body expansion-scaled external correlation method to extrapolate the calculated energies to the limit of a complete basis set and, most importantly, the limit of an infinite configuration interaction expansion. The topographical features of the novel potential energy surface are then examined in detail and compared with corresponding attributes of other potential functions available in the literature. Exploratory trajectories have also been run on this DMBE form with the quasiclassical trajectory method, with the thermal rate constant so determined at room temperature significantly enhancing agreement with experimental data.
Enabling Microfluidics: From Clean Rooms to Makerspaces
2016-09-30
anyone can make 133 and rapidly scale to bulk manufacturing . To enable others to take part in this type of product 134 design and development, we...cost molds for a fee; however, the 77 design process is slowed down waiting for molds to be manufactured and shipped. While 78 PDMS devices may be...finished prototype into a commercial product . An example of a rapid 101 prototyping method amenable to scaled-up manufacturing is laser cutting. Figure
Lee, S W; Southall, J C; Gleason, N R; Huang, E H; Bessler, M; Whelan, R L
2000-03-01
Our laboratory has demonstrated that significantly more cell-mediated immunosuppression occurs after full laparotomy than after either anesthesia control or carbon dioxide (CO2) pneumoperitoneum. We further demonstrated that the postoperative immunosuppression is related to the length of the incision. Other investigators believe that the immunosuppression observed after laparotomy is caused by peritoneal exposure to small amounts of lipopolysaccharide found in circulating air. They believe that the better-preserved immune function associated with laparoscopic surgery results from the avoidance of air contamination of the peritoneal cavity. To investigate this hypothesis, we determined and compared postoperative lymphocyte proliferation rates after (a) laparotomy in room air, (b) laparotomy in a CO2 chamber, (c) CO2 insufflation in a murine model, and (d) anesthesia alone. Female C3H/He mice (n = 21) were divided randomly into four groups: (a) anesthesia control, (b) air laparotomy, (c) CO2 laparotomy, and (d) CO2 insufflation. The control mice underwent no procedure. The group 2 animals underwent a full midline incision (xiphoid to pubis) and exposure to room air for 20 min and then were clipped closed. The group 3 mice underwent a full midline incision in a sealed CO2 chamber for 20 min, and the group 4 mice insufflation with CO2 gas at 4 to 6 mm Hg for 20 min. Splenocytes were harvested from all the animals on day 2 after the interventions. Lymphocyte proliferation then was assessed using the nonradioactive colorimetric MTS/PMS system 72 h after concanavalin-A stimulation. There was no significant difference in lymphocyte proliferation between the air and CO2 laparotomy groups. Lymphocyte proliferation in the anesthesia control and CO2 insufflation groups was significantly higher than in both the air laparotomy (p<0.05) and CO2 laparotomy (p<0.05) groups (p values by Tukey-Kramer test). There was no significant difference between the anesthesia control and CO2 pneumoperitoneum groups. Our results suggest that full laparotomy performed in a sealed CO2 chamber compared to room air laparotomy resulted in similar suppression of lymphocyte proliferation. Furthermore, no significant suppression of lymphocyte proliferation was observed in the CO2 pneumoperitoneum group. These results, with regard to lymphocyte proliferation rates, refute the hypothesis that postoperative immunosuppression is related to air exposure and support the alternative hypothesis that immunosuppression is related to incision length.
Ford, Clyde D; Lopansri, Bert K; Gazdik, Michaela A; Webb, Brandon; Snow, Gregory L; Hoda, Daanish; Adams, Barbara; Petersen, Finn Bo
2016-10-01
Contaminated surfaces and colonization pressure are risk factors for vancomycin-resistant Enterococcus (VRE) colonization in intensive care units (ICUs). Whether these apply to modern units dedicated to the care of hematologic malignancies and hematopoietic stem cell transplant (HSCT) procedures is unknown. We reviewed the records of 780 consecutive admissions for acute leukemia, autologous HSCT, or allogeneic HSCT in which the patient was at risk for hospital-acquired VRE and underwent weekly surveillance. We also obtained staff and room cultures, observed staff behavior, and performed VRE molecular strain typing on selected isolates. The overall rate of VRE colonization was 11.4 cases/1,000 patient days. Cultures of room surfaces revealed VRE isolates in 10% of terminally cleaned rooms. A prior VRE-colonized room occupant did not increase risk, and paired isolates from 20 patients and prior occupants were indistinguishable on molecular typing in only 1 pair. VRE colonization pressure was significantly associated with acquisition. Cultures of unit personnel and shared equipment were negative except for weighing scales. Observation of unit clinical personnel showed high compliance for hand sanitation and but less so for gowns. Conversely, ancillary staff showed poor compliance. Transmission of VRE from room surfaces seems to be an infrequent event. Encouraging adherence to surveillance, disinfection, and contact isolation protocols may decrease VRE colonization rates. Copyright © 2016. Published by Elsevier Inc.
Yield of illicit indoor cannabis cultivation in the Netherlands.
Toonen, Marcel; Ribot, Simon; Thissen, Jac
2006-09-01
To obtain a reliable estimation on the yield of illicit indoor cannabis cultivation in The Netherlands, cannabis plants confiscated by the police were used to determine the yield of dried female flower buds. The developmental stage of flower buds of the seized plants was described on a scale from 1 to 10 where the value of 10 indicates a fully developed flower bud ready for harvesting. Using eight additional characteristics describing the grow room and cultivation parameters, regression analysis with subset selection was carried out to develop two models for the yield of indoor cannabis cultivation. The median Dutch illicit grow room consists of 259 cannabis plants, has a plant density of 15 plants/m(2), and 510 W of growth lamps per m(2). For the median Dutch grow room, the predicted yield of female flower buds at the harvestable developmental stage (stage 10) was 33.7 g/plant or 505 g/m(2).
Quantum correlations from a room-temperature optomechanical cavity.
Purdy, T P; Grutter, K E; Srinivasan, K; Taylor, J M
2017-06-23
The act of position measurement alters the motion of an object being measured. This quantum measurement backaction is typically much smaller than the thermal motion of a room-temperature object and thus difficult to observe. By shining laser light through a nanomechanical beam, we measure the beam's thermally driven vibrations and perturb its motion with optical force fluctuations at a level dictated by the Heisenberg measurement-disturbance uncertainty relation. We demonstrate a cross-correlation technique to distinguish optically driven motion from thermally driven motion, observing this quantum backaction signature up to room temperature. We use the scale of the quantum correlations, which is determined by fundamental constants, to gauge the size of thermal motion, demonstrating a path toward absolute thermometry with quantum mechanically calibrated ticks. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
Acoustic buffeting by infrasound in a low vibration facility.
MacLeod, B P; Hoffman, J E; Burke, S A; Bonn, D A
2016-09-01
Measurement instruments and fabrication tools with spatial resolution on the atomic scale require facilities that mitigate the impact of vibration sources in the environment. One approach to protection from vibration in a building's foundation is to place the instrument on a massive inertia block, supported on pneumatic isolators. This opens the questions of whether or not a massive floating block is susceptible to acoustic forces, and how to mitigate the effects of any such acoustic buffeting. Here this is investigated with quantitative measurements of vibrations and sound pressure, together with finite element modeling. It is shown that a particular concern, even in a facility with multiple acoustic enclosures, is the excitation of the lowest fundamental acoustic modes of the room by infrasound in the low tens of Hz range, and the efficient coupling of the fundamental room modes to a large inertia block centered in the room.
Long distance spin communication in chemical vapour deposited graphene
NASA Astrophysics Data System (ADS)
Kamalakar, M. Venkata; Groenveld, Christiaan; Dankert, André; Dash, Saroj P.
2015-04-01
Graphene is an ideal medium for long-distance spin communication in future spintronic technologies. So far, the prospect is limited by the smaller sizes of exfoliated graphene flakes and lower spin transport properties of large-area chemical vapour-deposited (CVD) graphene. Here we demonstrate a high spintronic performance in CVD graphene on SiO2/Si substrate at room temperature. We show pure spin transport and precession over long channel lengths extending up to 16 μm with a spin lifetime of 1.2 ns and a spin diffusion length ~6 μm at room temperature. These spin parameters are up to six times higher than previous reports and highest at room temperature for any form of pristine graphene on industrial standard SiO2/Si substrates. Our detailed investigation reinforces the observed performance in CVD graphene over wafer scale and opens up new prospects for the development of lateral spin-based memory and logic applications.
Jiang, Hui-lin; Chan, Cangel Pui-yee; Leung, Yuk-ki; Li, Yun-mei; Graham, Colin A.; Rainer, Timothy H.
2014-01-01
Background and Purpose The objective of this study was to determine the performance of the Recognition Of Stroke In the Emergency Room (ROSIER) scale in risk-stratifying Chinese patients with suspected stroke in Hong Kong. Methods This was a prospective cohort study in an urban academic emergency department (ED) over a 7-month period. Patients over 18 years of age with suspected stroke were recruited between June 2011 and December 2011. ROSIER scale assessment was performed in the ED triage area. Logistic regression analysis was used to estimate the impacts of diagnostic variables, including ROSIER scale, past history and ED characteristics. Findings 715 suspected stroke patients were recruited for assessment, of whom 371 (52%) had acute cerebrovascular disease (302 ischaemic strokes, 24 transient ischaemic attacks (TIA), 45 intracerebral haemorrhages), and 344 (48%) had other illnesses i.e. stroke mimics. Common stroke mimics were spinal neuropathy, dementia, labyrinthitis and sepsis. The suggested cut-off score of>0 for the ROSIER scale for stroke diagnosis gave a sensitivity of 87% (95%CI 83–90), a specificity of 41% (95%CI 36–47), a positive predictive value of 62% (95%CI 57–66), and a negative predictive value of 75% (95%CI 68–81), and the AUC was 0.723. The overall accuracy at cut off>0 was 65% i.e. (323+141)/715. Interpretation The ROSIER scale was not as effective at differentiating acute stroke from stroke mimics in Chinese patients in Hong Kong as it was in the original studies, primarily due to a much lower specificity. If the ROSIER scale is to be clinically useful in Chinese suspected stroke patients, it requires further refinement. PMID:25343496
Heated Ultrasound Gel and Patient Satisfaction with Bedside Ultrasound Studies: The HUGS Trial
Krainin, Benjamin M.; Thaut, Lane C.; April, Michael D.; Curtis, Ryan A.; Kaelin, Andrea L.; Hardy, Garrett B.; Weymouth, Wells L.; Srichandra, Jonathan; Chin, Eric J.; Summers, Shane M.
2017-01-01
Introduction Our goal was to determine if heated gel for emergency department (ED) bedside ultrasonography improves patient satisfaction compared to room-temperature gel. Methods We randomized a convenience sample of ED patients determined by their treating physician to require a bedside ultrasound (US) study to either heated gel (102.0° F) or room-temperature gel (82.3° F). Investigators performed all US examinations. We informed all subjects that the study entailed investigation into various measures to improve patient satisfaction with ED US examinations but did not inform them of our specific focus on gel temperature. Investigators wore heat-resistant gloves while performing the examinations to blind themselves to the gel temperature. After completion of the US, subjects completed a survey including the primary outcome measure of patient satisfaction as measured on a 100-mm visual analogue scale (VAS). A secondary outcome was patient perceptions of sonographer professionalism measured by an ordinal scale (1–5). Results We enrolled 124 subjects; 120 completed all outcome measures. Of these, 59 underwent randomization to US studies with room-temperature gel and 61 underwent randomization to heated US gel. Patient 100-mm VAS satisfaction scores were 83.9 among patients undergoing studies with room-temperature gel versus 87.6 among subjects undergoing studies with heated gel (effect size 3.7, 95% confidence interval −1.3–8.6). There were similarly no differences between the two arms with regard to patient perceptions of sonographer professionalism. Conclusion The use of heated ultrasound gel appears to have no material impact on the satisfaction of ED patients undergoing bedside ultrasound studies. PMID:29085538
NASA Astrophysics Data System (ADS)
Lu, Haifei; Sun, Jingsong; Zhang, Hong; Lu, Shunmian; Choy, Wallace C. H.
2016-03-01
The exploration of low-temperature and solution-processed charge transporting and collecting layers can promote the development of low-cost and large-scale perovskite solar cells (PVSCs) through an all solution process. Here, we propose a room-temperature solution-processed and metal oxide-free nano-composite composed of a silver nano-network and graphene oxide (GO) flawless film for the transparent bottom electrode of a PVSC. Our experimental results show that the amount of GO flakes play a critical role in forming the flawless anti-corrosive barrier in the silver nano-network through a self-assembly approach under ambient atmosphere, which can effectively prevent the penetration of liquid or gaseous halides and their corrosion against the silver nano-network underneath. Importantly, we simultaneously achieve good work function alignment and surface wetting properties for a practical bottom electrode by controlling the degree of reduction of GO flakes. Finally, flexible PVSC adopting the room-temperature and solution-processed nano-composite as the flexible transparent bottom electrode has been demonstrated on a polyethylene terephthalate (PET) substrate. As a consequence, the demonstration of our room-temperature solution-processed and metal oxide-free flexible transparent bottom electrode will contribute to the emerging large-area flexible PVSC technologies.The exploration of low-temperature and solution-processed charge transporting and collecting layers can promote the development of low-cost and large-scale perovskite solar cells (PVSCs) through an all solution process. Here, we propose a room-temperature solution-processed and metal oxide-free nano-composite composed of a silver nano-network and graphene oxide (GO) flawless film for the transparent bottom electrode of a PVSC. Our experimental results show that the amount of GO flakes play a critical role in forming the flawless anti-corrosive barrier in the silver nano-network through a self-assembly approach under ambient atmosphere, which can effectively prevent the penetration of liquid or gaseous halides and their corrosion against the silver nano-network underneath. Importantly, we simultaneously achieve good work function alignment and surface wetting properties for a practical bottom electrode by controlling the degree of reduction of GO flakes. Finally, flexible PVSC adopting the room-temperature and solution-processed nano-composite as the flexible transparent bottom electrode has been demonstrated on a polyethylene terephthalate (PET) substrate. As a consequence, the demonstration of our room-temperature solution-processed and metal oxide-free flexible transparent bottom electrode will contribute to the emerging large-area flexible PVSC technologies. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00011h
77 FR 12814 - North Pacific Fishery Management Council; Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-02
....m. to 4 p.m. ADDRESSES: The meeting will be held at the Hilton Hotel, Aleutian Room, 500 W. Third... Bristol Bay red king crab fishery; statewide scallops. Determination of next committee meeting and/or full...
75 FR 62690 - Radio Broadcasting Services; Grants Pass, Oregon
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-13
..., adopted September 24, 2010, and released September 27, 2010. The full text of this Commission decision is..., Portals II, 445 12th Street, SW., Room CY-A257, Washington, DC 20554. The complete text of this decision...
Toxicity of combustion products from burning polymers: development and evaluation of methods
Wright, P. L.; Adams, C. H.
1976-01-01
Laboratory and room-scale experiments were conducted with natural and synthetic polymers: cotton, paper, wood, wool, acetate, acrylic, nylon, and urethane. Smoke and off-gases from single materials were generated in a dual-compartment 110-liter exposure chamber. Multicomponent, composite fuel loads were burned within a 100 m3 facility subdivided into rooms. In chamber experiments, mortality depended on the amount of material burned, i.e., fuel consumption (FC). Conventional dose (FC)/mortality curves were obtained, and the amount of fuel required to produce 50% mortality (FC50) was calculated. With simple flame ignition, cotton was the only material that produced smoke concentrations lethal to rats; FC50 values for cotton ranged from 2 g to 9 g, depending on the configuration of the cotton sample burned. When supplemental conductive heat was added to flame ignition, the following FC50 values were obtained; nylon, 7 g; acrylic, 8 g; newsprint, 9 g; cotton, 10 g; and wood, 11 g. Mortality resulting from any given material depended upon the specific conditions employed for its thermal decomposition. Toxicity of off-gasses from pyrolysis of phosphorus-containing trimethylol propane—polyurethane foams was markedly decreased by addition of a flame ignition source. Further studies are needed to determine the possible relevance of single-material laboratory scale smoke toxicity experiments. Room-scale burns were conducted to assess the relative contributions of single materials to toxicity of smoke produced by a multicomponent self-perpetuating fire. Preliminary results suggest that this approach permits a realistic evaluation of the contribution of single materials to the toxicity of smoke from residential fires. ImagesFIGURE 2. PMID:1026420
Custodial Services End of Year Report for 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konetzni, Joshua B.
Sandia’s Custodial Services Department is a full-service, in-house custodial department. The department consists of one manager, four team supervisors, three administrative support personnel, 11 lead custodians, 71 day-shift custodians, four swing shift custodians, and eight heavy floor care personnel. The department services approximately 3.5 million square feet of office, lobby, laboratory, break room, classroom, and conference room space and assists with the collection of recycling products, including aluminum, plastic, card board box, and mixed paper products. Detailed in this report are audits, awards, and certifications; department highlights; departmental promotions; custodial metrics.
NASA Astrophysics Data System (ADS)
Mekuria, Rufael; Cesar, Pablo; Doumanis, Ioannis; Frisiello, Antonella
2015-09-01
Compression of 3D object based video is relevant for 3D Immersive applications. Nevertheless, the perceptual aspects of the degradation introduced by codecs for meshes and point clouds are not well understood. In this paper we evaluate the subjective and objective degradations introduced by such codecs in a state of art 3D immersive virtual room. In the 3D immersive virtual room, users are captured with multiple cameras, and their surfaces are reconstructed as photorealistic colored/textured 3D meshes or point clouds. To test the perceptual effect of compression and transmission, we render degraded versions with different frame rates in different contexts (near/far) in the scene. A quantitative subjective study with 16 users shows that negligible distortion of decoded surfaces compared to the original reconstructions can be achieved in the 3D virtual room. In addition, a qualitative task based analysis in a full prototype field trial shows increased presence, emotion, user and state recognition of the reconstructed 3D Human representation compared to animated computer avatars.
Lean management in academic surgery.
Collar, Ryan M; Shuman, Andrew G; Feiner, Sandra; McGonegal, Amy K; Heidel, Natalie; Duck, Mary; McLean, Scott A; Billi, John E; Healy, David W; Bradford, Carol R
2012-06-01
Lean is a management system designed to enhance productivity by eliminating waste. Surgical practice offers many opportunities for improving efficiency. Our objective was to determine whether systematic implementation of lean thinking in an academic otolaryngology operating room improves efficiency and profitability and preserves team morale and educational opportunities. In an 18-month prospective quasi-experimental study, a multidisciplinary task force systematically implemented lean thinking within an otolaryngology operating room of an academic health system. Operating room turnover time and turnaround time were measured during a baseline period; an observer-effect period in which workers were made aware that their efficiency was being measured but before implementing lean changes; and an intervention period after redesign principles had been used. The impact on teamwork, morale, and surgical resident education were measured during the baseline and intervention periods through validated surveys. A profit model was applied to estimate the financial implications of the study. There was no difference between the baseline and observer-effect periods of the study for turnover time (p = 0.98) or turnaround time (p = 0.20). During the intervention period, the mean turnover time and turnaround time were significantly shorter than during the baseline period (29 vs 38 minutes; p < 0.001 and 69 vs 89 minutes; p < 0.001, respectively). The composite morale score suggested improved morale after implementation (p = 0.011). Educational metrics were unchanged before and after implementation. The annual opportunity revenue for the involved operating room is $330,000; when extrapolated throughout the operating rooms, lean thinking could create 6,500 hours of capacity annually. Application of lean management techniques to a single operating room and surgical service improved operating room efficiency and morale, sustained resident education, and can provide considerable financial gains when scaled to an entire academic surgical suite. Copyright © 2012. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Elbakary, Mohamed I.; Iftekharuddin, Khan M.; Papelis, Yiannis; Newman, Brett
2017-05-01
Air Traffic Management (ATM) concepts are commonly tested in simulation to obtain preliminary results and validate the concepts before adoption. Recently, the researchers found that simulation is not enough because of complexity associated with ATM concepts. In other words, full-scale tests must eventually take place to provide compelling performance evidence before adopting full implementation. Testing using full-scale aircraft produces a high-cost approach that yields high-confidence results but simulation provides a low-risk/low-cost approach with reduced confidence on the results. One possible approach to increase the confidence of the results and simultaneously reduce the risk and the cost is using unmanned sub-scale aircraft in testing new concepts for ATM. This paper presents the simulation results of using unmanned sub-scale aircraft in implementing ATM concepts compared to the full scale aircraft. The results of simulation show that the performance of sub-scale is quite comparable to that of the full-scale which validates use of the sub-scale in testing new ATM concepts. Keywords: Unmanned
76 FR 27004 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
... DEPARTMENT OF COMMERCE Submission for OMB Review; Comment Request The Department of Commerce will... of state and local government finance data collected on a nationwide scale using uniform definitions..., Departmental Paperwork Clearance Officer, (202) 482-0266, Department of Commerce, Room 6616, 14th and...
The Effects of Workload and Working Conditions on Operating Room Nurses and Technicians.
Uğurlu, Ziyafet; Karahan, Azize; Ünlü, Hayriye; Abbasoğlu, Aysel; Özhan Elbaş, Nalan; Avcı Işık, Sevcan; Tepe, Aylin
2015-09-01
This study was conducted between August 15 and September 20, 2013, to determine the effects of workload and working conditions on operating room (OR) nurses and technicians. The study sample included 74 OR nurses and technicians working in a private university's six hospitals. The Individual Workload Perception Scale and a questionnaire that collected data on risk and environmental factors were used. The mean age of study participants was 29.3 ± 6.7 years, and 62.2% of the participants were female. More than 90% of the nurses and technicians had experienced spills or splashing of blood or other body fluids; anesthetic gases and radiation had affected 63.5% and 71.6% of nurses and technicians, respectively; 63.5% reported lumbar pain; and 46.6% defined the work environment as very stressful. The average workload scale score was 32.4 ± 6.2 (min = 11, max = 55). OR nurses and technicians are exposed to many occupational risks. © 2015 The Author(s).
A robust molecular probe for Ångstrom-scale analytics in liquids
Nirmalraj, Peter; Thompson, Damien; Dimitrakopoulos, Christos; Gotsmann, Bernd; Dumcenco, Dumitru; Kis, Andras; Riel, Heike
2016-01-01
Traditionally, nanomaterial profiling using a single-molecule-terminated scanning probe is performed at the vacuum–solid interface often at a few Kelvin, but is not a notion immediately associated with liquid–solid interface at room temperature. Here, using a scanning tunnelling probe functionalized with a single C60 molecule stabilized in a high-density liquid, we resolve low-dimensional surface defects, atomic interfaces and capture Ångstrom-level bond-length variations in single-layer graphene and MoS2. Atom-by-atom controllable imaging contrast is demonstrated at room temperature and the electronic structure of the C60–metal probe complex within the encompassing liquid molecules is clarified using density functional theory. Our findings demonstrates that operating a robust single-molecular probe is not restricted to ultra-high vacuum and cryogenic settings. Hence the scope of high-precision analytics can be extended towards resolving sub-molecular features of organic elements and gauging ambient compatibility of emerging layered materials with atomic-scale sensitivity under experimentally less stringent conditions. PMID:27516157
Real-time atomistic observation of structural phase transformations in individual hafnia nanorods
Hudak, Bethany M.; Depner, Sean W.; Waetzig, Gregory R.; ...
2017-05-12
High-temperature phases of hafnium dioxide have exceptionally high dielectric constants and large bandgaps, but quenching them to room temperature remains a challenge. Scaling the bulk form to nanocrystals, while successful in stabilizing the tetragonal phase of isomorphous ZrO 2, has produced nanorods with a twinned version of the room temperature monoclinic phase in HfO 2. Here we use in situ heating in a scanning transmission electron microscope to observe the transformation of an HfO 2 nanorod from monoclinic to tetragonal, with a transformation temperature suppressed by over 1000°C from bulk. When the nanorod is annealed, we observe with atomic-scale resolutionmore » the transformation from twinned-monoclinic to tetragonal, starting at a twin boundary and propagating via coherent transformation dislocation; the nanorod is reduced to hafnium on cooling. Unlike the bulk displacive transition, nanoscale size-confinement enables us to manipulate the transformation mechanism, and we observe discrete nucleation events and sigmoidal nucleation and growth kinetics.« less
Diaconescu, Bogdan; Nenchev, Georgi; de la Figuera, Juan; Pohl, Karsten
2007-10-01
We describe the design and performance of a fast-scanning, variable temperature scanning tunneling microscope (STM) operating from 80 to 700 K in ultrahigh vacuum (UHV), which routinely achieves large scale atomically resolved imaging of compact metallic surfaces. An efficient in-vacuum vibration isolation and cryogenic system allows for no external vibration isolation of the UHV chamber. The design of the sample holder and STM head permits imaging of the same nanometer-size area of the sample before and after sample preparation outside the STM base. Refractory metal samples are frequently annealed up to 2000 K and their cooldown time from room temperature to 80 K is 15 min. The vertical resolution of the instrument was found to be about 2 pm at room temperature. The coarse motor design allows both translation and rotation of the scanner tube. The total scanning area is about 8 x 8 microm(2). The sample temperature can be adjusted by a few tens of degrees while scanning over the same sample area.
Application of full-scale three-dimensional models in patients with rheumatoid cervical spine.
Mizutani, Jun; Matsubara, Takeshi; Fukuoka, Muneyoshi; Tanaka, Nobuhiko; Iguchi, Hirotaka; Furuya, Aiharu; Okamoto, Hideki; Wada, Ikuo; Otsuka, Takanobu
2008-05-01
Full-scale three-dimensional (3D) models offer a useful tool in preoperative planning, allowing full-scale stereoscopic recognition from any direction and distance with tactile feedback. Although skills and implants have progressed with various innovations, rheumatoid cervical spine surgery remains challenging. No previous studies have documented the usefulness of full-scale 3D models in this complicated situation. The present study assessed the utility of full-scale 3D models in rheumatoid cervical spine surgery. Polyurethane or plaster 3D models of 15 full-sized occipitocervical or upper cervical spines were fabricated using rapid prototyping (stereolithography) techniques from 1-mm slices of individual CT data. A comfortable alignment for patients was reproduced from CT data obtained with the patient in a comfortable occipitocervical position. Usefulness of these models was analyzed. Using models as a template, appropriate shape of the plate-rod construct could be created in advance. No troublesome Halo-vests were needed for preoperative adjustment of occipitocervical angle. No patients complained of dysphasia following surgery. Screw entry points and trajectories were simultaneously determined with full-scale dimensions and perspective, proving particularly valuable in cases involving high-riding vertebral artery. Full-scale stereoscopic recognition has never been achieved with any existing imaging modalities. Full-scale 3D models thus appear useful and applicable to all complicated spinal surgeries. The combination of computer-assisted navigation systems and full-scale 3D models appears likely to provide much better surgical results.
78 FR 25861 - Radio Broadcasting Services; Peach Springs, Arizona
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-03
... Docket No. 12-374, adopted March 1, 2013, and released March 1, 2013. The full text of this Commission..., Portals II, 445 12th Street SW., Room CY- A257, Washington, DC 20554. The complete text of this decision...
77 FR 32075 - Petitions for Reconsideration of Action of Rulemaking Proceeding
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-31
.... 2950, released May 24, 2012. The full text of this document is available for viewing and copying in Room CY-B402, 445 12th Street SW., Washington, DC or may be purchased from the Commission's copy...
76 FR 11737 - Petition for Reconsideration of Action of Rulemaking Proceeding
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-03
.... 2925, released February 7, 2011. The full text of this document is available for viewing and copying in Room CY-B402, 445 12th Street, SW., Washington, DC or may be purchased from the Commission's copy...
Orientation based on nursing diagnoses. Old concepts in today's practice.
Anderson, L K; Vincent, N
1991-10-01
Although many operating room orientation programs contain content necessary to meet accrediting guidelines, very few tie the nursing process to the content. Our orientation is structured within a nursing framework (ie, Dr Gordon's "Eleven Functional Health Patterns") and emphasizes nursing diagnoses, theory, and clinical competencies. Although the new orientation program has been in effect for only two years, we feel the following list reflects the positive outcomes so far: decreased staff turnover (ie, one nurse out of 26 full-time equivalents in 18 months), increased success in recruiting nurses into the operating room (ie, multiple applicants as positions open), new nurses demonstrate comfort with basic perioperative nursing practice with-in six months, and nurses who did not complete new orientation program are requesting all or portions of the content. By using this plan, essential aspects of perioperative practice are consistent with hospital-wide nursing practice, practice standards for the operating room, and accrediting standards.
Amorphization of nanocrystalline 3C-SiC irradiated with Si+ ions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Weilin; Wang, Haiyan; Kim, Ickchan
2010-11-23
Irradiation induced amorphization in nanocrystalline and single crystal 3C-SiC has been studied using 1 MeV Si+ ions under the identical irradiation conditions at room temperature and 400 K. The disordering behavior has been characterized using in-situ ion channeling and ex-situ x-ray diffraction methods. The results show that, compared to single crystal 3C-SiC, full amorphization of small 3C-SiC grains (~3.8 nm in size) occurs at a slightly lower dose at room temperature. For grains with sizes of 3.0 - 3.8 nm, the amorphization dose is lower at room temperature than 400 K. A significantly lower dose for amorphization of smaller grainsmore » (2.0 nm in size) is observed at 400 K. The behavior has been interpreted based on the competition between the interface and interior amorphization.« less
Experimental system, and its evaluation for the control of surgically inducted infections
NASA Technical Reports Server (NTRS)
Tevebaugh, M. D.; Nelson, J. P.
1972-01-01
The effect is reported to design, fabricate, test and evaluate a prototype experimental system for the control of surgically induced infections. The purpose is to provide the cleanest possible environment within a hospital surgery room and eliminate contamination sources that could cause infections during surgery. The system design is described. The system provides for a portable laminar flow clean room, a full bubble helmet system with associated communications and ventilation subsystems for operating room personnel, and surgical gowns that minimize the migration of bacteria. The development test results consisting of portability, laminar flowrate, air flow pattern, electrostatic buildup, noise level, ventilation, human factors, electrical and material compatibility tests are summarized. The conclusions are that the experimental system is effective in reducing the airborne and wound contamination although the helmets and gowns may not be a significant part of this reduction. Definitive conclusions with regard to the infection rate cannot be made at this time.
Micro-environmental control for efficient local cooling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kong, Meng; Dang, Thong Q.; Zhang, Jianshun
Micro-environment is hereby defined as the air space and environment around a person that directly impacts his/her thermal sensation. Most existing HVAC systems condition the air of the entire room including the unoccupied space, which leaves a big potential to save energy. This study aims at evaluating the performance of three existing air terminal devices (ATDs) to locally remove enough heat from the micro-environment to manage the thermal balance so as not to sacrifice thermal comfort when the ambient unoccupied space temperature is increased by 2.2 °C from 23.9 °C to 26.1 °C in the summer to reduce the externalmore » cooling load. A computational fluid dynamics (CFD) model was developed, validated by full-scale chamber tests and applied to evaluate different configurations of the ATDs for local cooling. Results show that the predicted performance agreed well with the measurements, and the selected ATD, with only 50 W cooling power, was always able to remove a sufficient amount of heat from the microenvironment in a room of raised temperature, when the manikin was moved inside a semicircle movement range. The cooling performance of the jet was increased more by increasing the supply air flow rate than reducing the supply temperature and was highly dependent on the shooting angle. Finally, the heat flux from the manikin surface is very sensitive to the surface temperature and furniture placement, and proper specification of the surface temperature is crucial for the CFD simulation to match the measured results.« less
Micro-environmental control for efficient local cooling
Kong, Meng; Dang, Thong Q.; Zhang, Jianshun; ...
2017-06-01
Micro-environment is hereby defined as the air space and environment around a person that directly impacts his/her thermal sensation. Most existing HVAC systems condition the air of the entire room including the unoccupied space, which leaves a big potential to save energy. This study aims at evaluating the performance of three existing air terminal devices (ATDs) to locally remove enough heat from the micro-environment to manage the thermal balance so as not to sacrifice thermal comfort when the ambient unoccupied space temperature is increased by 2.2 °C from 23.9 °C to 26.1 °C in the summer to reduce the externalmore » cooling load. A computational fluid dynamics (CFD) model was developed, validated by full-scale chamber tests and applied to evaluate different configurations of the ATDs for local cooling. Results show that the predicted performance agreed well with the measurements, and the selected ATD, with only 50 W cooling power, was always able to remove a sufficient amount of heat from the microenvironment in a room of raised temperature, when the manikin was moved inside a semicircle movement range. The cooling performance of the jet was increased more by increasing the supply air flow rate than reducing the supply temperature and was highly dependent on the shooting angle. Finally, the heat flux from the manikin surface is very sensitive to the surface temperature and furniture placement, and proper specification of the surface temperature is crucial for the CFD simulation to match the measured results.« less
Use of patient safety culture instruments in operating rooms: A systematic literature review.
Zhao, Pujng; Li, Yaqin; Li, Zhi; Jia, Pengli; Zhang, Longhao; Zhang, Mingming
2017-05-01
To identify and qualitatively describe, in a literature review, how the instruments were used to evaluate patient safety culture in the operating rooms of published studies. Systematic searches of the literature were conducted using the major database including MEDLINE, EMbase, The Cochrane Library, and four Chinese databases including Chinese Biomedical Literature Database (CBM), Wanfang Data, Chinese Scientific Journal Database (VIP), and Chinese Journals Full-text Database (CNKI) for studies published up to March 2016. We summarized and analyzed the country scope, the instrument utilized in the study, the year when the instrument was used, and fields of operating rooms. Study populations, study settings, and the time span between baseline and follow-up phase were evaluated according to the study design. We identified 1025 references, of which 99 were obtained for full-text assessment; 47 of these studies were deemed relevant and included in the literature review. Most of the studies were from the USA. The most commonly used patient safety culture instrument was Safety Attitude Questionnaire. All identified instruments were used after 2002 and across many fields. Most included studies on patient safety culture were conducted in teaching hospitals or university hospitals. The study population in the cross-sectional studies was much more than that in the before-after studies. The time span between baseline and follow-up phase of before-after studies were almost over three months. Although patient safety culture is considered important in health care and patient safety, the number of studies in which patient safety culture has been estimated using the instruments in operating rooms, is fairly small. © 2017 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.
The University of Texas M.D. Anderson Cancer Center Proton Therapy Facility
NASA Astrophysics Data System (ADS)
Smith, Alfred; Newhauser, Wayne; Latinkic, Mitchell; Hay, Amy; McMaken, Bruce; Styles, John; Cox, James
2003-08-01
The University of Texas M.D. Anderson Cancer Center (MDACC), in partnership with Sanders Morris Harris Inc., a Texas-based investment banking firm, and The Styles Company, a developer and manager of hospitals and healthcare facilities, is building a proton therapy facility near the MDACC main complex at the Texas Medical Center in Houston, Texas USA. The MDACC Proton Therapy Center will be a freestanding, investor-owned radiation oncology center offering state-of-the-art proton beam therapy. The facility will have four treatment rooms: three rooms will have rotating, isocentric gantries and the fourth treatment room will have capabilities for both large and small field (e.g. ocular melanoma) treatments using horizontal beam lines. There will be an additional horizontal beam room dedicated to physics research and development, radiation biology research, and outside users who wish to conduct experiments using proton beams. The first two gantries will each be initially equipped with a passive scattering nozzle while the third gantry will have a magnetically swept pencil beam scanning nozzle. The latter will include enhancements to the treatment control system that will allow for the delivery of proton intensity modulation treatments. The proton accelerator will be a 250 MeV zero-gradient synchrotron with a slow extraction system. The facility is expected to open for patient treatments in the autumn of 2005. It is anticipated that 675 patients will be treated during the first full year of operation, while full capacity, reached in the fifth year of operation, will be approximately 3,400 patients per year. Treatments will be given up to 2-shifts per day and 6 days per week.
Cho, S. J.; Cox-Ganser, J. M.; Park, J.-H.
2015-01-01
We examined associations between observational dampness scores and measurements of microbial agents and moisture in three public schools. A dampness score was created for each room from 4-point-scale scores (0–3) of water damage, water stains, visible mold, moldy odor, and wetness for each of 8 room components (ceiling, walls, windows, floor, ventilation, furniture, floor trench, and pipes), when present. We created mixed microbial exposure indices (MMEIs) for each of 121 rooms by summing decile ranks of 8 analytes (total culturable fungi; total, Gram-negative, and Gram-positive culturable bacteria; ergosterol; (1→3)-β-D-glucan; muramic acid; and endotoxin) in floor dust. We found significant (P ≤ 0.01) linear associations between the dampness score and culturable bacteria (total, Gram-positive, and Gram-negative) and the MMEIs. Rooms with dampness scores greater than 0.25 (median) had significantly (P < 0.05) higher levels of most microbial agents, MMEIs, and relative moisture content than those with lower scores (≤0.25). Rooms with reported recent water leaks had significantly (P < 0.05) higher dampness scores than those with historical or no reported water leaks. This study suggests that observational assessment of dampness and mold using a standardized form may be valuable for identifying and documenting water damage and associated microbial contamination. PMID:25650175
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, H.S.; Stone, C.M.
A pretest reference calculation for the Geomechanical Evaluation or Room G experiment is presented. The Geomechanical Evaluation is one of several large-scale in situ tests currently under construction near Carlsbad, New Mexico, at the site of the Waste Isolation Pilot Plant (WIPP). The Room G experiment consists of isolated, two-dimensional drifts with different room spans, an isolated drift intersection, and a wedge pillar. The primary purpose of the experiment is to provide data for validating computational modeling capabilities used in analyzing nuclear waste repositories in salt. The calculation presented here addresses only one portion of the test, namely isolated driftmore » configurations which are initially 6.1 m (20 ft) wide by 3.05 m (10 ft) high. The Geomechanical Evaluation is heavily instrumented for monitoring deformations due to creep of the salt. Data from the experiment are not available at the present time, but the measurements for Room G will eventually be compared to the results presented in this report to assess and improve structural modeling capabilities for the WIPP. The model used for this calculation represents the state of the art at the present time. A large number of plots are included since an appropriate result is presented for every gage location associated with the 6.1 m wide drifts. 53 refs., 53 figs., 3 tabs.« less
Pretest reference calculation for the Heated Axisymmetric Pillar (WIPP Room H in situ experiment)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, H.S.; Stone, C.M.
A pretest reference calculation for the Heated Axisymmetric Pillar or Room H experiment is presented in this report. The Heated Axisymmetric Pillar is one of several large scale in situ experiments currently under construction near Carlsbad, New Mexico, at the site of the Waste Isolation Pilot Plant (WIPP). This test is an intermediate step in validating numerical techniques for design and performance calculations for radioactive waste repositories in salt. The test consists of a cylindrically shaped pillar, centrally located in an annular drift, which is uniformly heated by blanket heaters. These heaters produce a thermal output of 135 W/m/sup 2/.more » This load will be supplied for a period of three years. Room H is heavily instrumented for monitoring both temperature increases due to the thermal loading and deformations due to creep of the salt. Data from the experiment are not available at the present time, but the measurements for Room H will eventually be compared to the calculation presented in this report to assess and improve thermal and mechanical modeling capabilities for the WIPP. The thermal/structural model used in the calculation represents the state of the art at the present time. A large number of plots are included since an appropriate result is required for every Room H gauge location. 56 refs., 97 figs., 4 tabs.« less
A Method for Estimating Noise from Full-Scale Distributed Exhaust Nozzles
NASA Technical Reports Server (NTRS)
Kinzie, Kevin W.; Schein, David B.
2004-01-01
A method to estimate the full-scale noise suppression from a scale model distributed exhaust nozzle (DEN) is presented. For a conventional scale model exhaust nozzle, Strouhal number scaling using a scale factor related to the nozzle exit area is typically applied that shifts model scale frequency in proportion to the geometric scale factor. However, model scale DEN designs have two inherent length scales. One is associated with the mini-nozzles, whose size do not change in going from model scale to full scale. The other is associated with the overall nozzle exit area which is much smaller than full size. Consequently, lower frequency energy that is generated by the coalesced jet plume should scale to lower frequency, but higher frequency energy generated by individual mini-jets does not shift frequency. In addition, jet-jet acoustic shielding by the array of mini-nozzles is a significant noise reduction effect that may change with DEN model size. A technique has been developed to scale laboratory model spectral data based on the premise that high and low frequency content must be treated differently during the scaling process. The model-scale distributed exhaust spectra are divided into low and high frequency regions that are then adjusted to full scale separately based on different physics-based scaling laws. The regions are then recombined to create an estimate of the full-scale acoustic spectra. These spectra can then be converted to perceived noise levels (PNL). The paper presents the details of this methodology and provides an example of the estimated noise suppression by a distributed exhaust nozzle compared to a round conic nozzle.
Impact of different isolation procedures on the functionality of zein and kafirin
USDA-ARS?s Scientific Manuscript database
Commercial corn prolamin (zein) aggregates in water above room temperature into an extensible, viscoelastic gluten-like substance. This specific functionality of zein can be used in the production of superior gluten-free bread. The present study examined laboratory-scale isolation of such functional...
NASA Astrophysics Data System (ADS)
Gupta, Shashank; Nam, Donguk; Vuckovic, Jelena; Saraswat, Krishna
2018-04-01
A complementary metal-oxide semiconductor compatible on-chip light source is the holy grail of silicon photonics and has the potential to alleviate the key scaling issues arising due to electrical interconnects. Despite several theoretical predictions, a sustainable, room temperature laser from a group-IV material is yet to be demonstrated. In this work, we show that a particular loss mechanism, inter-valence-band absorption (IVBA), has been inadequately modeled until now and capturing its effect accurately as a function of strain is crucial to understanding light emission processes from uniaxially strained germanium (Ge). We present a detailed model of light emission in Ge that accurately models IVBA in the presence of strain and other factors such as polarization, doping, and carrier injection, thereby revising the road map toward a room temperature Ge laser. Strikingly, a special resonance between gain and loss mechanisms at 4%-5% 〈100 〉 uniaxial strain is found resulting in a high net gain of more than 400 cm-1 at room temperature. It is shown that achieving this resonance should be the goal of experimental work rather than pursuing a direct band gap Ge.
NASA Technical Reports Server (NTRS)
Schmidt, Gene I.; Rossow, Vernon J.; Vanaken, Johannes M.; Parrish, Cynthia L.
1987-01-01
The features of a 1/50-scale model of the National Full-Scale Aerodynamics Complex are first described. An overview is then given of some results from the various tests conducted with the model to aid in the design of the full-scale facility. It was found that the model tunnel simulated accurately many of the operational characteristics of the full-scale circuits. Some characteristics predicted by the model were, however, noted to differ from previous full-scale results by about 10%.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-01
... Capstone Mining Corp.'' Complainant alleges that Respondent is an Alaska corporation which operates as a... full text of the complaint can be found in the Commission's Electronic Reading Room at http://www.fmc...
Resonant tunneling in nanocolumns improved by quantum collimation.
Wensorra, Jakob; Indlekofer, Klaus Michael; Lepsa, Mihail Ion; Förster, Arno; Lüth, Hans
2005-12-01
We report on a quantum collimation effect based on surface depletion regions in AlAs/GaAs nanocolumns with an embedded resonant tunneling structure. The considered MBE-grown nanodevices have been fabricated by means of a top-down approach that employs a reproducible lithographic definition of the vertical nanocolumns. By analyzing the scaling properties of these nanodevices, we discuss how a collimation effect due to a saddle point in the confining potential can explain an improved device performance of the ultimately scaled structures at room temperature.
Oolong tea increases metabolic rate and fat oxidation in men.
Rumpler, W; Seale, J; Clevidence, B; Judd, J; Wiley, E; Yamamoto, S; Komatsu, T; Sawaki, T; Ishikura, Y; Hosoda, K
2001-11-01
According to traditional Chinese belief, oolong tea is effective in the control of body weight. Few controlled studies, however, have been conducted to measure the impact of tea on energy expenditure (EE) of humans. A randomized cross-over design was used to compare 24-h EE of 12 men consuming each of four treatments: 1) water, 2) full-strength tea (daily allotment brewed from 15 g of tea), 3) half-strength tea (brewed from 7.5 g tea) and 4) water containing 270 mg caffeine, equivalent to the concentration in the full-strength tea treatment. Subjects refrained from consuming caffeine or flavonoids for 4 d prior to the study. Tea was brewed each morning; beverages were consumed at room temperature as five 300 mL servings. Subjects received each treatment for 3 d; on the third day, EE was measured by indirect calorimetry in a room calorimeter. For the 3 d, subjects consumed a typical American diet. Energy content of the diet was tailored to each subject's needs as determined from a preliminary measure of 24-h EE by calorimetry. Relative to the water treatment, EE was significantly increased 2.9 and 3.4% for the full-strength tea and caffeinated water treatments, respectively. This increase over water alone represented an additional expenditure of 281 and 331 kJ/d for subjects treated with full-strength tea and caffeinated water, respectively. In addition, fat oxidation was significantly higher (12%) when subjects consumed the full-strength tea rather than water.
NASA Technical Reports Server (NTRS)
Jackson, Karen E.; Fasanella, Edwin L.; Lyle, Karen H.
2003-01-01
A 25-fps vertical drop test of a 1/5-scale model composite fuselage section was conducted to replicate a previous test of a full-scale fuselage section. The purpose of the test was to obtain experimental data characterizing the impact response of the 1/5-scale model fuselage section for comparison with the corresponding full-scale data. This comparison is performed to assess the scaling procedures and to determine if scaling effects are present. For the drop test, the 1/5-scale model fuselage section was configured in a similar manner as the full-scale section, with lead masses attached to the floor through simulated seat rails. Scaled acceleration and velocity responses are compared and a general assessment of structural damage is made. To further quantify the data correlation, comparisons of the average acceleration data are made as a function of floor location and longitudinal position. Also, the percentage differences in the velocity change (area under the acceleration curve) and the velocity change squared (proportional to kinetic energy) are compared as a function of floor location. Finally, correlation coefficients are calculated for corresponding 1/5- and full-scale data channels and these values are plotted versus floor location. From a scaling perspective, the differences between the 1/5- and full-scale tests are relatively small, indicating that appropriate scaling procedures were used in fabricating the test specimens and in conducting the experiments. The small differences in the scaled test data are attributed to minor scaling anomalies in mass, potential energy, and impact attitude.
Impact and fracture analysis of fish scales from Arapaima gigas.
Torres, F G; Malásquez, M; Troncoso, O P
2015-06-01
Fish scales from the Amazonian fish Arapaima gigas have been characterised to study their impact and fracture behaviour at three different environmental conditions. Scales were cut in two different directions to analyse the influence of the orientation of collagen layers. The energy absorbed during impact tests was measured for each sample and SEM images were taken after each test in order to analyse the failure mechanisms. The results showed that scales tested at cryogenic temperatures display fragile behaviour, while scales tested at room temperature did not fracture. Different failure mechanisms have been identified, analysed and compared with the failure modes that occur in bone. The impact energy obtained for fish scales was two to three times higher than the values reported for bone in the literature. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Anderson, B. H.; Dryer, M.; Hearth, D. P.
1957-01-01
The performance of a full-scale translating-spike inlet was obtained at Mach numbers of 1.8 and 2.0 and at angles of attach from 0 deg to 6 deg. Comparisons were made between the full-scale production inlet configuration and a geometrically similar quarter-scale model. The inlet pressure-recovery, cowl pressure-distribution, and compressor-face distortion characteristics of the full-scale inlet agreed fairly well with the quarter-scale results. In addition, the results indicated that bleeding around the periphery ahead of the compressor-face station improved pressure recovery and compressor-face distortion, especially at angle of attack.
Does the Room Matter? Active Learning in Traditional and Enhanced Lecture Spaces
ERIC Educational Resources Information Center
Stoltzfus, Jon R.; Libarkin, Julie
2016-01-01
SCALE-UP-type classrooms, originating with the Student-Centered Active Learning Environment with Upside-down Pedagogies project, are designed to facilitate active learning by maximizing opportunities for interactions between students and embedding technology in the classroom. Positive impacts when active learning replaces lecture are well…
A green single-step synthesis of iron nanoparticles using tea (Camellia sinensis) polyphenols is described that uses no added surfactants/polymers as a capping or reducing agents. The expeditious reaction between polyphenols and ferric nitrate occurs within few minutes at room te...
The Empathy Cycle: Refinement of a Nuclear Concept.
ERIC Educational Resources Information Center
Barrett-Lennard, G.T.
1981-01-01
Delineates a sequence of distinct stages involved in empathic interaction. There is room for considerable slippage between the inner resonation, communication, and reception levels, and measures based on data from different phases would at best be moderately associated. Principal existing (state) scales are located in reference to the model.…
Learning Theory and Psychometrics: Room for Growth
ERIC Educational Resources Information Center
Briggs, Derek C.
2017-01-01
In the United States, students have historically taken large-scale assessments for many different purposes. One purpose that is shared with many other countries is a desire to monitor aggregate trends in educational attainment in core subject domains such as literacy, mathematics, and science. In this commentary, the author examines testing,…
THE EFFECT OF ACTIVATED CARBON SURFACE MOISTURE ON LOW TEMPERATURE MERCURY ADSORPTION
Experiments with elemental mercury (Hg0) adsorption by activated carbons were performed using a bench-scale fixed-bed reactor at room temperature (27 degrees C) to determine the role of surface moisture in capturing Hg0. A bituminous-coal-based activated carbon (BPL) and an activ...
Why Online Education Will Attain Full Scale
ERIC Educational Resources Information Center
Sener, John
2010-01-01
Online higher education has attained scale and is poised to take the next step in its growth. Although significant obstacles to a full scale adoption of online education remain, we will see full scale adoption of online higher education within the next five to ten years. Practically all higher education students will experience online education in…
Full scale tank car coupler impact tests
DOT National Transportation Integrated Search
2003-11-15
Full scale tests were performed to investigate various : aspects of tank car behavior during coupler impacts. A tank car : was equipped with 37 accelerometers and an instrumented : coupler. Two series of full scale coupler impact tests, : comprising ...
Report for Task 8.4: Development of Control Room Layout Recommendations
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, Robert
Idaho National Laboratory (INL) has contracted Institutt for Energiteknikk (IFE) to support in the development of an end state vision for the US Nuclear industry and in particular for a utility that is currently moving forward with a control room modernization project. This support includes the development of an Overview display and technical support in conducting an operational study. Development of operational scenarios to be conducted using a full scope simulator at the INL HSSL. Additionally IFE will use the CREATE modelling tool to provide 3-D views of the potential and possible end state view after the completion of digitalmore » upgrade project.« less
The temperature dependence of the tensile properties of thermally treated Alloy 690 tubing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrod, D.L.; Gold, R.E.; Larsson, B.
1992-12-31
Tensile tests were run in air on full tube cross-sections of 22.23 mm OD by 1.27 mm wall thickness Alloy 690 steam generator production tubes from ten (10) heats of material at eight (8) temperatures between room temperature and 760{degrees}C. The tubing was manufactured to specification requirements consistent with the EPRI guidelines for Alloy 690 tubing. The room temperature stress-strain curves are described quite well by the Voce equation. Ductile fracture by dimpled rupture was observed at all test temperatures. The elevated temperature tensile properties are compared with design data given in the ASME Code.
The delivery room of the future: the fetal and neonatal resuscitation and transition suite.
Finer, Neil N; Rich, Wade; Halamek, Louis P; Leone, Tina A
2012-12-01
Despite advances in the understanding of fetal and neonatal physiology and the technology to monitor and treat premature and full-term neonates, little has changed in resuscitation rooms. The authors' vision for the Fetal and Neonatal Resuscitation and Transition Suite of the future is marked by improvements in the amount of physical space, monitoring technologies, portable diagnostic and therapeutic technologies, communication systems, and capabilities and training of the resuscitation team. Human factors analysis will play an important role in the design and testing of the improvements for safe, effective, and efficient resuscitation of the newborn. Copyright © 2012 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Boesdorfer, Sarah; Greenhalgh, Scott
2014-01-01
The "Next Generation Science Standards" (NGSS Lead States 2013) urge science teachers to include engineering practices and ideas in their already full science curriculum, but many teachers do not know where to start. Only 7% of high school science teachers report feeling "very well prepared" to teach engineering. The…
ERIC Educational Resources Information Center
Kemp, Wayne
2009-01-01
This publication describes options for designing and equipping middle and high school music education suites, and suggests ways of gaining community support for including full service music suites in new and renovated school facilities. In addition to basic music suites, and practice rooms, other options detailed include: (1) small ensemble…
RF Conditioning and Testing of Fundamental Power Couplers for SNS Superconducting Cavity Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. Stirbet; G.K. Davis; M. A. Drury
The Spallation Neutron Source (SNS) makes use of 33 medium beta (0.61) and 48 high beta (0.81) superconducting cavities. Each cavity is equipped with a fundamental power coupler, which should withstand the full klystron power of 550 kW in full reflection for the duration of an RF pulse of 1.3 msec at 60 Hz repetition rate. Before assembly to a superconducting cavity, the vacuum components of the coupler are submitted to acceptance procedures consisting of preliminary quality assessments, cleaning and clean room assembly, vacuum leak checks and baking under vacuum, followed by conditioning and RF high power testing. Similar acceptancemore » procedures (except clean room assembly and baking) were applied for the airside components of the coupler. All 81 fundamental power couplers for SNS superconducting cavity production have been RF power tested at JLAB Newport News and, beginning in April 2004 at SNS Oak Ridge. This paper gives details of coupler processing and RF high power-assessed performances.« less
Experimental and analytical studies of advanced air cushion landing systems
NASA Technical Reports Server (NTRS)
Lee, E. G. S.; Boghani, A. B.; Captain, K. M.; Rutishauser, H. J.; Farley, H. L.; Fish, R. B.; Jeffcoat, R. L.
1981-01-01
Several concepts are developed for air cushion landing systems (ACLS) which have the potential for improving performance characteristics (roll stiffness, heave damping, and trunk flutter), and reducing fabrication cost and complexity. After an initial screening, the following five concepts were evaluated in detail: damped trunk, filled trunk, compartmented trunk, segmented trunk, and roll feedback control. The evaluation was based on tests performed on scale models. An ACLS dynamic simulation developed earlier is updated so that it can be used to predict the performance of full-scale ACLS incorporating these refinements. The simulation was validated through scale-model tests. A full-scale ACLS based on the segmented trunk concept was fabricated and installed on the NASA ACLS test vehicle, where it is used to support advanced system development. A geometrically-scaled model (one third full scale) of the NASA test vehicle was fabricated and tested. This model, evaluated by means of a series of static and dynamic tests, is used to investigate scaling relationships between reduced and full-scale models. The analytical model developed earlier is applied to simulate both the one third scale and the full scale response.
Moreno, Lyman; Predicala, Bernardo; Nemati, Mehdi
2010-04-01
The effects of manure age on emission of H(2)S and required level of nitrite or molybdate to control these emissions were investigated in the present work. Molybdate mediated control of H(2)S emission was also studied in semi-pilot scale open systems, and in specifically designed chambers which simulated swine production rooms. With fresh 1-, 3- and 6-month old manures average H(2)S concentration in the headspace gas of the closed systems were 4856+/-460, 3431+/-208, 1037+/-98 ppm and non-detectable, respectively. Moreover, the level of nitrite or molybdate required to control the emission of H(2)S decreased as manure age increased. In the semi-pilot scale open system and chambers, average H(2)S concentration at the surface of agitated fresh manure were 831+/-26 and 88.4+/-5.7 ppm, respectively. Furthermore, 0.1-0.25 mM molybdate was sufficient to control the emission of H(2)S. A cost study for an average size swine operation showed that the cost of treatment with molybdate was less than 1% of the overall production cost for each market hog. Copyright 2009 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lloyd-Hughes, James; Mosley, C. D. W.; Jones, S. P. P.
Colossal magnetoresistance (CMR) is demonstrated at terahertz (THz) frequencies by using terahertz time-domain magnetospectroscopy to examine vertically aligned nanocomposites (VANs) and planar thin films of La 0.7Sr 0.3MnO 3. At the Curie temperature (room temperature), the THz conductivity of the VAN was dramatically enhanced by over 2 orders of magnitude under the application of a magnetic field with a non-Drude THz conductivity that increased with frequency. The direct current (dc) CMR of the VAN is controlled by extrinsic magnetotransport mechanisms such as spin-polarized tunneling between nanograins. In contrast, we find that THz CMR is dominated by intrinsic, intragrain transport: themore » mean free path was smaller than the nanocolumn size, and the planar thin-film exhibited similar THz CMR to the VAN. Surprisingly, the observed colossal THz magnetoresistance suggests that the magnetoresistance can be large for alternating current motion on nanometer length scales, even when the magnetoresistance is negligible on the macroscopic length scales probed by dc transport. This suggests that colossal magnetoresistance at THz frequencies may find use in nanoelectronics and in THz optical components controlled by magnetic fields. As a result, the VAN can be scaled in thickness while retaining a high structural quality and offers a larger THz CMR at room temperature than the planar film.« less
Method of installing a control room console in a nuclear power plant
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1994-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Advanced nuclear plant control room complex
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1993-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Airframe noise of a small model transport aircraft and scaling effects. [Boeing 747
NASA Technical Reports Server (NTRS)
Shearin, J. G.
1981-01-01
Airframe noise of a 0.01 scale model Boeing 747 wide-body transport was measured in the Langley Anechoic Noise Facility. The model geometry simulated the landing and cruise configurations. The model noise was found to be similar in noise characteristics to that possessed by a 0.03 scale model 747. The 0.01 scale model noise data scaled to within 3 dB of full scale data using the same scaling relationships as that used to scale the 0.03 scale model noise data. The model noise data are compared with full scale noise data, where the full scale data are calculated using the NASA aircraft noise prediction program.
Airframe noise of a small model transport aircraft and scaling effects
NASA Astrophysics Data System (ADS)
Shearin, J. G.
1981-05-01
Airframe noise of a 0.01 scale model Boeing 747 wide-body transport was measured in the Langley Anechoic Noise Facility. The model geometry simulated the landing and cruise configurations. The model noise was found to be similar in noise characteristics to that possessed by a 0.03 scale model 747. The 0.01 scale model noise data scaled to within 3 dB of full scale data using the same scaling relationships as that used to scale the 0.03 scale model noise data. The model noise data are compared with full scale noise data, where the full scale data are calculated using the NASA aircraft noise prediction program.
Owor, Betty E; Shepherd, Dionne N; Taylor, Nigel J; Edema, Richard; Monjane, Adérito L; Thomson, Jennifer A; Martin, Darren P; Varsani, Arvind
2007-03-01
Leaf samples from 155 maize streak virus (MSV)-infected maize plants were collected from 155 farmers' fields in 23 districts in Uganda in May/June 2005 by leaf-pressing infected samples onto FTA Classic Cards. Viral DNA was successfully extracted from cards stored at room temperature for 9 months. The diversity of 127 MSV isolates was analysed by PCR-generated RFLPs. Six representative isolates having different RFLP patterns and causing either severe, moderate or mild disease symptoms, were chosen for amplification from FTA cards by bacteriophage phi29 DNA polymerase using the TempliPhi system. Full-length genomes were inserted into a cloning vector using a unique restriction enzyme site, and sequenced. The 1.3-kb PCR product amplified directly from FTA-eluted DNA and used for RFLP analysis was also cloned and sequenced. Comparison of cloned whole genome sequences with those of the original PCR products indicated that the correct virus genome had been cloned and that no errors were introduced by the phi29 polymerase. This is the first successful large-scale application of FTA card technology to the field, and illustrates the ease with which large numbers of infected samples can be collected and stored for downstream molecular applications such as diversity analysis and cloning of potentially new virus genomes.
Surface tension anomalies in room temperature ionic liquids-acetone solutions
NASA Astrophysics Data System (ADS)
Abe, Hiroshi; Murata, Keisuke; Kiyokawa, Shota; Yoshimura, Yukihiro
2018-05-01
Surface tension anomalies were observed in room temperature ionic liquid (RTIL)-acetone solutions. The RTILs are 1-alkyl-3-methylimidazorium iodide with [Cnmim][I] in a [Cnmim][I]-x mol% acetone. The maximum value of the surface tension appeared at 40 mol% acetone, although density decreased monotonically with an increase in acetone concentration. A small alkyl chain length effect of the Cnmim+ cations was observed in the surface tension. By the Gibbs adsorption isotherm, it was found that I- anion-mediated surface structure became dominant above 40 mol%. In the different [Cnmim][TFSI]-acetone mixtures, normal decay of the surface tension was observed on the acetone concentration scale, where TFSI- is bis(trifluoromethanesulfonyl)imide.
Weather support area, floor plan and details. ("Alter COC, Bldg. ...
Weather support area, floor plan and details. ("Alter COC, Bldg. 2605, Weather Support Area, Floor Plan & Details" Also includes a site plan and a finish schedule. The exact location of this construction is obscure, but it appears to be the enclosure of space at the north end of room 101, the "Display Area" or "War Room") Strategic Air Command, Civil Engineering. Drawing no. B-1081, sheet no. 1 of 2, 9 July 1968; project no. MAR-132-8; CE-562; file drawer 2605-9, also 1315. Various scales. 29x41 inches. pencil on paper - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA
Fabrication of Josephson Junction without shadow evaporation
NASA Astrophysics Data System (ADS)
Wu, Xian; Ku, Hsiangsheng; Long, Junling; Pappas, David
We developed a new method of fabricating Josephson Junction (Al/AlOX/Al) without shadow evaporation. Statistics from room temperature junction resistance and measurement of qubits are presented. Unlike the traditional ``Dolan Bridge'' technique, this method requires two individual lithographies and straight evaporations of Al. Argon RF plasma is used to remove native AlOX after the first evaporation, followed by oxidation and second Al evaporation. Junction resistance measured at room temperature shows linear dependence on Pox (oxidation pressure), √{tox} (oxidation time), and inverse proportional to junction area. We have seen 100% yield of qubits made with this method. This method is promising because it eliminates angle dependence during Junction fabrication, facilitates large scale qubits fabrication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Dacheng; Department of Aeronautics, Fujian Key Laboratory for Plasma and Magnetic Resonance, School of Physics and Mechanical and Electrical Engineering, Xiamen University, Xiamen, Fujian 361005; Zhao Di
2011-04-18
This letter reports a stable air surface barrier discharge device for large-area sterilization applications at room temperature. This design may result in visually uniform plasmas with the electrode area scaled up (or down) to the required size. A comparison for the survival rates of Escherichia coli from air, N{sub 2} and O{sub 2} surface barrier discharge plasmas is presented, and the air surface plasma consisting of strong filamentary discharges can efficiently kill Escherichia coli. Optical emission measurements indicate that reactive species such as O and OH generated in the room temperature air plasmas play a significant role in the sterilizationmore » process.« less
Zhang, Yang; Tang, Liguo; Tian, Hua; Wang, Jiyang; Cao, Wenwu; Zhang, Zhongwu
2017-08-15
Resonant ultrasound spectroscopy (RUS) was used to determine the temperature dependence of full matrix material constants of PZT-8 piezoceramics from room temperature to 100 °C. Property variations from sample to samples can be eliminated by using only one sample, so that data self-consistency can be guaranteed. The RUS measurement system error was estimated to be lower than 2.35%. The obtained full matrix material constants at different temperatures all have excellent self-consistency, which can help accurately predict device performance at high temperatures using finite element simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K.; Fowley, M.; Miller, D.
2016-12-01
Five experiments were completed with the full-scale, room temperature Hanford Waste Treatment and Immobilization Plant (WTP) high-level waste (HLW) melter riser test system to observe particle flow and settling in support of a crystal tolerant approach to melter operation. A prototypic pour rate was maintained based on the volumetric flow rate. Accumulation of particles was observed at the bottom of the riser and along the bottom of the throat after each experiment. Measurements of the accumulated layer thicknesses showed that the settled particles at the bottom of the riser did not vary in thickness during pouring cycles or idle periods.more » Some of the settled particles at the bottom of the throat were re-suspended during subsequent pouring cycles, and settled back to approximately the same thickness after each idle period. The cause of the consistency of the accumulated layer thicknesses is not year clear, but was hypothesized to be related to particle flow back to the feed tank. Additional experiments reinforced the observation of particle flow along a considerable portion of the throat during idle periods. Limitations of the system are noted in this report and may be addressed via future modifications. Follow-on experiments will be designed to evaluate the impact of pouring rate on particle re-suspension, the influence of feed tank agitation on particle accumulation, and the effect of changes in air lance positioning on the accumulation and re-suspension of particles at the bottom of the riser. A method for sampling the accumulated particles will be developed to support particle size distribution analyses. Thicker accumulated layers will be intentionally formed via direct addition of particles to select areas of the system to better understand the ability to continue pouring and re-suspend particles. Results from the room temperature system will be correlated with observations and data from the Research Scale Melter (RSM) at Pacific Northwest National Laboratory, and coordinated with modeling efforts underway at Idaho National Laboratory.« less
[Cost-effectiveness of the deep vein thrombosis diagnosis process in primary care].
Fuentes Camps, Eva; Luis del Val García, José; Bellmunt Montoya, Sergi; Hmimina Hmimina, Sara; Gómez Jabalera, Efren; Muñoz Pérez, Miguel Ángel
2016-04-01
To analyse the cost effectiveness of the application of diagnostic algorithms in patients with a first episode of suspected deep vein thrombosis (DVT) in Primary Care compared with systematic referral to specialised centres. Observational, cross-sectional, analytical study. Patients from hospital emergency rooms referred from Primary Care to complete clinical evaluation and diagnosis. A total of 138 patients with symptoms of a first episode of DVT were recruited; 22 were excluded (no Primary Care report, symptoms for more than 30 days, anticoagulant treatment, and previous DVT). Of the 116 patients finally included, 61% women and the mean age was 71 years. Variables from the Wells and Oudega clinical probability scales, D-dimer (portable and hospital), Doppler ultrasound, and direct costs generated by the three algorithms analysed: all patients were referred systematically, referral according to Wells and Oudega scale. DVT was confirmed in 18.9%. The two clinical probability scales showed a sensitivity of 100% (95% CI: 85.1 to 100) and a specificity of about 40%. With the application of the scales, one third of all referrals to hospital emergency rooms could have been avoided (P<.001). The diagnostic cost could have been reduced by € 8,620 according to Oudega and € 9,741 according to Wells, per 100 patients visited. The application of diagnostic algorithms when a DVT is suspected could lead to better diagnostic management by physicians, and a more cost effective process. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Wang, Tianshuang; Yu, Qi; Zhang, Sufang; Kou, Xueying; Sun, Peng; Lu, Geyu
2018-03-08
The lower gas sensitivity, humidity dependence of the gas sensing properties, and long recovery times of room-temperature gas sensors severely limit their applications. Herein, to address these issues, a series of 3D inverse opal (IO) In 2 O 3 -ZnO heterogeneous composite microspheres (HCMs) are fabricated by ultrasonic spray pyrolysis (USP) employing self-assembled sulfonated polystyrene (S-PS) spheres as a sacrificial template. The 3D IO In 2 O 3 -ZnO HCMs possess highly ordered 3D inverse opal structures and bimodal (meso-scale and macro-scale) pores, which can provide large accessible surface areas and rapid mass transfer, resulting in enhanced gas sensing characteristics. Furthermore, the 3D IO architecture and n-n heterojunctions can extend the photoabsorption range to the visible light area, effectively prolonging the lifetimes of photo-generated charge carriers, and can increase separation of visible light-generated charges. As a result, the as-prepared 3D IO In 2 O 3 -ZnO HCMs deliver excellent NO 2 sensing performance under visible light irradiation at room temperature, such as high sensitivity (R gas /R air = 54.3 to 5 ppm NO 2 ), low detection limit (250 ppb), fast recovery time (188 s), excellent selectivity and humidity independence. These enhanced photo-electronic gas sensing properties are attributed to the combination of highly ordered 3D IO microspheres and In 2 O 3 -ZnO heterogeneous composites.
Fernández, L; Scher, H; VanderGheynst, J S
2015-12-01
Prior research has demonstrated that microalgae can be stored for extended periods of time at room temperature in water-in-oil (W/O) emulsions stabilized by surface modified silica nanoparticles. However, little research has been done to examine the impact of nanoparticle concentration on emulsion stability. Such information is important for large-scale production of emulsions for microalgae storage and delivery. Studies were done to examine the impact of silica nanoparticle concentration on emulsion stability and identify the lower limit for nanoparticle concentration. Emulsion physical stability was determined using internal phase droplet size measurements and biological stability was evaluated using cell density measurements. The results demonstrate that nanoparticle concentrations as low as 0·5wt% in the oil phase can be used without significant losses in emulsion stability and microalgae viability. Stabilization technologies are needed for long-term storage and application of microalgae in agricultural-scale systems. While prior work has demonstrated that water-in-oil emulsions containing silica nanoparticles offer a promising solution for long-term microalgae storage at room temperature, little research has been done to examine the impact of nanoparticle concentration on emulsion stability. Here, we show the effects of silica nanoparticle concentration on maintaining physical stability of emulsions and sustaining viable cells. The results enable informed decisions to be made regarding production of emulsions containing silica nanoparticles and associated impacts on stabilization of microalgae. © 2015 The Society for Applied Microbiology.
Pretest 3D finite element analysis of the WIPP Intermediate Scale Borehole Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arguello, J.G.
A three dimensional pretest finite element analysis of the Intermediate Scale Borehole Test has been performed. In the analysis, the 7.7 years simulation period includes the mining of Rooms C1 and C2, and the N1420 cross drift, at time zero; drilling of the borehole between the two rooms at 5.7 years; and 2 years of post-drilling response. An all salt configuration was used in the calculation. The 1984 Waste Isolation Pilot Plant (WIPP) reference elastic-secondary creep law, with reduced elastic moduli, was used to model the creeping response of the salt. Results show that after mining of the rooms andmore » cross drift a relatively high von Mises stress state exists around the perimeter of the pillar. However, by 5.7 years, or immediately prior to drilling of the borehole, the pillar has relaxed to an almost uniform von Mises stress of about 7--8 MPa. After the borehole is drilled, a relatively high von Mises stress field is once again set up in the immediate vicinity of the hole. This drives the creep closure of the borehole. The hole closes more in the vertical direction than in the horizontal direction, resulting in ovalling of the hole. At the end of the simulation, the von Mises stress around the borehole is still higher than that in the remained of the pillar. Thus, the closure rates are relatively high at the end of the simulation time.« less
Evaluating different concentrations of hydrogen peroxide in an automated room disinfection system.
Murdoch, L E; Bailey, L; Banham, E; Watson, F; Adams, N M T; Chewins, J
2016-09-01
A comparative study was made on the efficacy of 5, 10 and 35% weight by weight (w/w) hydrogen peroxide solutions when applied using an automated room disinfection system. Six-log biological indicators of methicillin-resistant Staphylococcus aureus (MRSA) and Geobacillus stearothermophilus were produced on stainless steel coupons and placed within a large, sealed, environmentally controlled enclosure. Five percent hydrogen peroxide was distributed throughout the enclosure using a Bioquell hydrogen peroxide vapour generator (BQ-50) for 40 min and left to reside for a further 200 min. Biological indicators were removed at 10-min intervals throughout the first 120 min of the process. The experiment was repeated for 10 and 35% hydrogen peroxide solutions. Five percent and 10% hydrogen peroxide solutions failed to achieve any reduction of MRSA, but achieved full kill of G. stearothermophilus spores at 70 and 40 min respectively. Thirty-five percent hydrogen peroxide achieved a 6-log reduction of MRSA after 30 min and full kill of G. stearothermophilus at 20 min. The concentration of 5% hydrogen peroxide within the enclosure after the 200-min dwell was measured at 9·0 ppm. This level exceeds the 15-min Short Term Exposure Limit (STEL) for hydrogen peroxide of 2·0 ppm. Users of automated hydrogen peroxide disinfection systems should review system efficacy and room re-entry protocols in light of these results. This research allows hospital infection control teams to consider the impact and risks of using low concentrations of hydrogen peroxide for disinfection within their facilities, and to question automated room disinfection system providers on the efficacy claims they make. The evidence that low concentration hydrogen peroxide solutions do not rapidly, autonomously break down, is in contradiction to the claims made by some hydrogen peroxide equipment providers and raises serious health and safety concerns. Facilities using hydrogen peroxide systems that claim autonomous break down of hydrogen peroxide should introduce monitoring procedures to ensure rooms are safe for re-entry and patient occupation. © 2016 The Society for Applied Microbiology.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-01
...: This is a summary of the Commission's document, Report No. 2937, released November 15, 2011. The full text of this document is available for viewing and copying in Room CY-B402, 445 12th Street SW...
Design of full-scale adsorption systems typically includes expensive and time-consuming pilot studies to simulate full-scale adsorber performance. Accordingly, the rapid small-scale column test (RSSCT) was developed and evaluated experimentally. The RSSCT can simulate months of f...
NASA Astrophysics Data System (ADS)
Mookerjea, Saurabh A.
Over the past decade the microprocessor clock frequency has hit a plateau. The main reason for this has been the inability to follow constant electric field scaling, which requires the transistor supply voltage to be scaled down as the transistor dimensions are reduced. Scaling the supply voltage down reduces the dynamic power quadratically but increases the static leakage power exponentially due to non-scalability of threshold voltage of the transistor, which is required to maintain the same ON state performance. This limitation in supply voltage scaling is directly related to MOSFET's (Metal Oxide Semiconductor Field Effect Transistor) sub-threshold slope (SS) limitation of 60 mV/dec at room temperature. Thus novel device design/materials are required that would allow the transistor to switch with sub-threshold slopes steeper than 60 mV/dec at room temperature, thus facilitating supply voltage scaling. Recently, a new class of devices known as super-steep slope (SS<60 mV/dec) transistors are under intense research for its potential to replace the ubiquitous MOSFET. The focus of this dissertation is on the design, fabrication and characterization of band-to-band tunneling field effect transistor (TFET) which belongs to the family of steep slope transistors. TFET with a gate modulated zener tunnel junction at the source allows sub-kT/q (sub-60 mV/dec at room temperature) sub-threshold slope (SS) device operation over a certain gate bias range near the off-state. This allows TFET to achieve much higher I ON-IOFF ratio over a specified gate voltage swing compared to MOSFETs, thus enabling aggressive supply voltage scaling for low power logic operation without impacting its ON-OFF current ratio. This dissertation presents the operating principle of TFET, the material selection strategy and device design for TFET fabrication. This is followed by a novel 6T SRAM design which circumvents the issue of unidirectional conduction in TFET. The switching behavior of TFET is studied through mixed-mode numerical simulations. The significance of correct benchmarking methodology to estimate the effective drive current and capacitance in TFET is highlighted and compared with MOSFET. This is followed by the fabrication details of homo-junction TFET. Analysis of the electrical characteristics of homo-junction TFET gives key insight into its device operation and identifies the critical factors that impact its performance. In order to boost the ON current, the design and fabrication of hetero-junction TFET is also presented.
Alsved, M; Civilis, A; Ekolind, P; Tammelin, A; Andersson, A Erichsen; Jakobsson, J; Svensson, T; Ramstorp, M; Sadrizadeh, S; Larsson, P-A; Bohgard, M; Šantl-Temkiv, T; Löndahl, J
2018-02-01
To evaluate three types of ventilation systems for operating rooms with respect to air cleanliness [in colony-forming units (cfu/m 3 )], energy consumption and comfort of working environment (noise and draught) as reported by surgical team members. Two commonly used ventilation systems, vertical laminar airflow (LAF) and turbulent mixed airflow (TMA), were compared with a newly developed ventilation technique, temperature-controlled airflow (T c AF). The cfu concentrations were measured at three locations in an operating room during 45 orthopaedic procedures: close to the wound (<40cm), at the instrument table and peripherally in the room. The operating team evaluated the comfort of the working environment by answering a questionnaire. LAF and T c AF, but not TMA, resulted in less than 10cfu/m 3 at all measurement locations in the room during surgery. Median values of cfu/m 3 close to the wound (250 samples) were 0 for LAF, 1 for T c AF and 10 for TMA. Peripherally in the room, the cfu concentrations were lowest for T c AF. The cfu concentrations did not scale proportionally with airflow rates. Compared with LAF, the power consumption of T c AF was 28% lower and there was significantly less disturbance from noise and draught. T c AF and LAF remove bacteria more efficiently from the air than TMA, especially close to the wound and at the instrument table. Like LAF, the new T c AF ventilation system maintained very low levels of cfu in the air, but T c AF used substantially less energy and provided a more comfortable working environment than LAF. This enables energy savings with preserved air quality. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Cho, S J; Cox-Ganser, J M; Park, J-H
2016-04-01
We examined associations between observational dampness scores and measurements of microbial agents and moisture in three public schools. A dampness score was created for each room from 4-point-scale scores (0-3) of water damage, water stains, visible mold, moldy odor, and wetness for each of 8 room components (ceiling, walls, windows, floor, ventilation, furniture, floor trench, and pipes), when present. We created mixed microbial exposure indices (MMEIs) for each of 121 rooms by summing decile ranks of 8 analytes (total culturable fungi; total, Gram-negative, and Gram-positive culturable bacteria; ergosterol; (1→3)-β-D-glucan; muramic acid; and endotoxin) in floor dust. We found significant (P ≤ 0.01) linear associations between the dampness score and culturable bacteria (total, Gram-positive, and Gram-negative) and the MMEIs. Rooms with dampness scores greater than 0.25 (median) had significantly (P < 0.05) higher levels of most microbial agents, MMEIs, and relative moisture content than those with lower scores (≤0.25). Rooms with reported recent water leaks had significantly (P < 0.05) higher dampness scores than those with historical or no reported water leaks. This study suggests that observational assessment of dampness and mold using a standardized form may be valuable for identifying and documenting water damage and associated microbial contamination. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Rastad, C; Ulfberg, J; Lindberg, P
2008-06-01
The most common way to provide bright light therapy to Swedish patients with Seasonal Affective Disorder (SAD), is treatment in a light therapy room. Since few studies have evaluated treatment provided in this setting and few have evaluated the effect of bright light in sub-clinical SAD (S-SAD), such a study including a one-month follow-up was designed. Fifty adults recruited from a previous prevalence study and clinically assessed as having SAD or S-SAD, were randomised to treatment in a light room or to a three-week waiting-list control group. The Hamilton Depression Rating Scale-Seasonal Affective Disorders Self-rating 29-items Version (SIGH-SAD/SR) was used to measure depressive mood at baseline, directly following treatment and at the one-month follow-up. ANCOVA with adjustment for baseline depression score, showed a significant main effect for the light room therapy group (p<0.001). Fifty-four percent (n=13/24) improved > or = 50% while no such improvement was seen in the control condition (n=0/24). After merging the two groups, repeated measures ANOVA confirmed the experimental analysis (p<0.001). At the one-month follow-up, 83.0% (n=39/47) had improved > or = 50% and 63.8% (n=30/47) had normal depression scores, i.e. < or = 8. Light room therapy was effective in reducing depressive symptoms in subjects with winter depressive mood. Results were maintained over a period of one month.
Infant Neurobehavioral Development
Lester, Barry M.; Miller, Robin J.; Hawes, Katheleen; Salisbury, Amy; Bigsby, Rosemarie; Sullivan, Mary C.; Padbury, James F.
2011-01-01
The trend toward single-room neonatal intensive care units (NICUs) is increasing; however scientific evidence is, at this point, mostly anecdotal. This is a critical time to assess the impact of the single-room NICU on improving medical and neurobehavioral outcomes of the preterm infant. We have developed a theoretical model that may be useful in studying how the change from an open-bay NICU to a single-room NICU could affect infant medical and neurobehavioral outcome. The model identifies mediating factors that are likely to accompany the change to a single-room NICU. These mediating factors include family centered care, developmental care, parenting and family factors, staff behavior and attitudes, and medical practices. Medical outcomes that plan to be measured are sepsis, length of stay, gestational age at discharge, weight gain, illness severity, gestational age at enteral feeding, and necrotizing enterocolitis (NEC). Neurobehavioral outcomes include the NICU Network Neurobehavioral Scale (NNNS) scores, sleep state organization and sleep physiology, infant mother feeding interaction scores, and pain scores. Preliminary findings on the sample of 150 patients in the open-bay NICU showed a “baseline” of effects of family centered care, developmental care, parent satisfaction, maternal depression, and parenting stress on the neurobehavioral outcomes of the newborn. The single-room NICU has the potential to improve the neurobehavioral status of the infant at discharge. Neurobehavioral assessment can assist with early detection and therefore preventative intervention to maximize developmental outcome. We also present an epigenetic model of the potential effects of maternal care on improving infant neurobehavioral status. PMID:21255702
NASA Technical Reports Server (NTRS)
Fares, Ehab; Duda, Benjamin; Khorrami, Mehdi R.
2016-01-01
Unsteady flow computations are presented for a Gulfstream aircraft model in landing configuration, i.e., flap deflected 39deg and main landing gear deployed. The simulations employ the lattice Boltzmann solver PowerFLOW(Trademark) to simultaneously capture the flow physics and acoustics in the near field. Sound propagation to the far field is obtained using a Ffowcs Williams and Hawkings acoustic analogy approach. Two geometry representations of the same aircraft are analyzed: an 18% scale, high-fidelity, semi-span model at wind tunnel Reynolds number and a full-scale, full-span model at half-flight Reynolds number. Previously published and newly generated model-scale results are presented; all full-scale data are disclosed here for the first time. Reynolds number and geometrical fidelity effects are carefully examined to discern aerodynamic and aeroacoustic trends with a special focus on the scaling of surface pressure fluctuations and farfield noise. An additional study of the effects of geometrical detail on farfield noise is also documented. The present investigation reveals that, overall, the model-scale and full-scale aeroacoustic results compare rather well. Nevertheless, the study also highlights that finer geometrical details that are typically not captured at model scales can have a non-negligible contribution to the farfield noise signature.
49 CFR 239.105 - Debriefing and critique.
Code of Federal Regulations, 2013 CFR
2013-10-01
... emergency situation or full-scale simulation to determine the effectiveness of its emergency preparedness... passenger train emergency situation or full-scale simulation. (b) Exceptions. (1) No debriefing and critique...; (2) How much time elapsed between the occurrence of the emergency situation or full-scale simulation...
49 CFR 239.105 - Debriefing and critique.
Code of Federal Regulations, 2011 CFR
2011-10-01
... emergency situation or full-scale simulation to determine the effectiveness of its emergency preparedness... passenger train emergency situation or full-scale simulation. (b) Exceptions. (1) No debriefing and critique...; (2) How much time elapsed between the occurrence of the emergency situation or full-scale simulation...
49 CFR 239.105 - Debriefing and critique.
Code of Federal Regulations, 2010 CFR
2010-10-01
... emergency situation or full-scale simulation to determine the effectiveness of its emergency preparedness... passenger train emergency situation or full-scale simulation. (b) Exceptions. (1) No debriefing and critique...; (2) How much time elapsed between the occurrence of the emergency situation or full-scale simulation...
49 CFR 239.105 - Debriefing and critique.
Code of Federal Regulations, 2012 CFR
2012-10-01
... emergency situation or full-scale simulation to determine the effectiveness of its emergency preparedness... passenger train emergency situation or full-scale simulation. (b) Exceptions. (1) No debriefing and critique...; (2) How much time elapsed between the occurrence of the emergency situation or full-scale simulation...
Effects of Various Architectural Parameters on Six Room Acoustical Measures in Auditoria.
NASA Astrophysics Data System (ADS)
Chiang, Wei-Hwa
The effects of architectural parameters on six room acoustical measures were investigated by means of correlation analyses, factor analyses and multiple regression analyses based on data taken in twenty halls. Architectural parameters were used to estimate acoustical measures taken at individual locations within each room as well as the averages and standard deviations of all measured values in the rooms. The six acoustical measures were Early Decay Time (EDT10), Clarity Index (C80), Overall Level (G), Bass Ratio based on Early Decay Time (BR(EDT)), Treble Ratio based on Early Decay Time (TR(EDT)), and Early Inter-aural Cross Correlation (IACC80). A comprehensive method of quantifying various architectural characteristics of rooms was developed to define a large number of architectural parameters that were hypothesized to effect the acoustical measurements made in the rooms. This study quantitatively confirmed many of the principles used in the design of concert halls and auditoria. Three groups of room architectural parameters such as the parameters associated with the depth of diffusing surfaces were significantly correlated with the hall standard deviations of most of the acoustical measures. Significant differences of statistical relations among architectural parameters and receiver specific acoustical measures were found between a group of music halls and a group of lecture halls. For example, architectural parameters such as the relative distance from the receiver to the overhead ceiling increased the percentage of the variance of acoustical measures that was explained by Barron's revised theory from approximately 70% to 80% only when data were taken in the group of music halls. This study revealed the major architectural parameters which have strong relations with individual acoustical measures forming the basis for a more quantitative method for advancing the theoretical design of concert halls and other auditoria. The results of this study provide designers the information to predict acoustical measures in buildings at very early stages of the design process without using computer models or scale models.
9 CFR 108.4 - Preparation of blueprints.
Code of Federal Regulations, 2014 CFR
2014-01-01
... regular blueprint paper or a good grade of white paper of any one of the American standard trimmed sizes... blueprint is revised. Indicate the scale used. (b) Use a single sheet of paper for each floor of all... floor. (e) Identify all rooms by letters or numbers. (f) Show the location of important stationary...
9 CFR 108.4 - Preparation of blueprints.
Code of Federal Regulations, 2011 CFR
2011-01-01
... regular blueprint paper or a good grade of white paper of any one of the American standard trimmed sizes... blueprint is revised. Indicate the scale used. (b) Use a single sheet of paper for each floor of all... floor. (e) Identify all rooms by letters or numbers. (f) Show the location of important stationary...
The Cosmic Connection Computer Interface For each count, the detector sends out a signal that is room temperature on the upper plot and the cosmic ray count rate per minute on the lower scale. Please contact us for more details on this setup. Sample Data for Cosmic Ray Detector Last modified: April 27
Spreading of lithium on a stainless steel surface at room temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skinner, C. H.; Capece, A. M.; Roszell, J. P.
Lithium conditioned plasma facing surfaces have lowered recycling and enhanced plasma performance on many fusion devices and liquid lithium plasma facing components are under consideration for future machines. A key factor in the performance of liquid lithium components is the wetting by lithium of its container. We have observed the surface spreading of lithium from a mm-scale particle to adjacent stainless steel surfaces using a scanning Auger microprobe that has elemental discrimination. Here, the spreading of lithium occurred at room temperature (when lithium is a solid) from one location at a speed of 0.62 μm/day under ultrahigh vacuum conditions. Separatemore » experiments using temperature programmed desorption (TPD) investigated bonding energetics between monolayer-scale films of lithium and stainless steel. While multilayer lithium desorption from stainless steel begins to occur just above 500 K (E des = 1.54 eV), sub-monolayer Li desorption occurred in a TPD peak at 942 K (E des = 2.52 eV) indicating more energetically favorable lithium-stainless steel bonding (in the absence of an oxidation layer) than lithium lithium bonding.« less
Spreading of lithium on a stainless steel surface at room temperature
Skinner, C. H.; Capece, A. M.; Roszell, J. P.; ...
2015-11-10
Lithium conditioned plasma facing surfaces have lowered recycling and enhanced plasma performance on many fusion devices and liquid lithium plasma facing components are under consideration for future machines. A key factor in the performance of liquid lithium components is the wetting by lithium of its container. We have observed the surface spreading of lithium from a mm-scale particle to adjacent stainless steel surfaces using a scanning Auger microprobe that has elemental discrimination. Here, the spreading of lithium occurred at room temperature (when lithium is a solid) from one location at a speed of 0.62 μm/day under ultrahigh vacuum conditions. Separatemore » experiments using temperature programmed desorption (TPD) investigated bonding energetics between monolayer-scale films of lithium and stainless steel. While multilayer lithium desorption from stainless steel begins to occur just above 500 K (E des = 1.54 eV), sub-monolayer Li desorption occurred in a TPD peak at 942 K (E des = 2.52 eV) indicating more energetically favorable lithium-stainless steel bonding (in the absence of an oxidation layer) than lithium lithium bonding.« less
Spreading of lithium on a stainless steel surface at room temperature
NASA Astrophysics Data System (ADS)
Skinner, C. H.; Capece, A. M.; Roszell, J. P.; Koel, B. E.
2016-01-01
Lithium conditioned plasma facing surfaces have lowered recycling and enhanced plasma performance on many fusion devices and liquid lithium plasma facing components are under consideration for future machines. A key factor in the performance of liquid lithium components is the wetting by lithium of its container. We have observed the surface spreading of lithium from a mm-scale particle to adjacent stainless steel surfaces using a scanning Auger microprobe that has elemental discrimination. The spreading of lithium occurred at room temperature (when lithium is a solid) from one location at a speed of 0.62 μm/day under ultrahigh vacuum conditions. Separate experiments using temperature programmed desorption (TPD) investigated bonding energetics between monolayer-scale films of lithium and stainless steel. While multilayer lithium desorption from stainless steel begins to occur just above 500 K (Edes = 1.54 eV), sub-monolayer Li desorption occurred in a TPD peak at 942 K (Edes = 2.52 eV) indicating more energetically favorable lithium-stainless steel bonding (in the absence of an oxidation layer) than lithium-lithium bonding.
Atomic-scale investigation and magnetic properties of Cu80Co20 nanowires
NASA Astrophysics Data System (ADS)
Hannour, A.; Lardé, R.; Jean, M.; Bran, J.; Pareige, P.; Le Breton, J. M.
2011-09-01
Cu80Co20 granular alloy nanowires were synthesized by electrodeposition method and investigated by x-ray diffraction (XRD), Laser Assisted Wide Angle Tomographic Atom Probe (LAWATAP), and SQUID magnetometry. XRD results reveal the existence of a fcc Cu matrix and fcc Co-rich nanograins, with a preferred orientation along the [200] direction (perpendicular to the substrate surface). The Co-rich nanograins could be coherent with the Cu matrix. 3D reconstructions of a nano-sized volume, obtained by LAWATAP, reveal the heterogeneous aspect of the Cu80Co20 nanowires: Co-rich nanoclusters with size between 2 and 10 nm are detected, and the presence of Cu and Co oxides is evidenced. Magnetization measurements indicate that the Co-rich nanoclusters are superparamagnetic, with a blocking temperature that extends up to, at least, room temperature. The presence of ferromagnetic domains at room temperature indicates that some Co-rich nanoclusters are correlated within a volume that corresponds to a so-called interacting superparamagnetic phase. As a matter of fact, by LAWATAP atomic-scale analysis, a very good correlation is obtained between microstructure and magnetic properties.
NASA Technical Reports Server (NTRS)
Rand, J. L.
1981-01-01
Previous attempts to develop an appropriate sensor for measuring the stress or strain of high altitude balloons during flight are reviewed as well as the various conditions that must be met by such a device. The design, development and calibration of a transducer which promises to satisfy the necessary design constraints are described. The thin film strain transducer has a low effective modulus so as not to interfere with the strain that would naturally occur in the balloon. In addition, the transducer has a high sensitivity to longitudinal strain (7.216 mV/V/unit strain) which is constant for all temperature from room temperature to -80 C and all strains from 5 percent compression to 10 percent tensile strain. At the same time, the sensor is relatively insensitive (0.27 percent) to transverse forces. The device has a standard 350 ohm impedance which is compatible with available bridge balance, amplification and telemetry instrumentation now available for balloon flight. Recommendations are included for improved coatings to provide passive thermal control as well as model, tethered and full scale flight testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Kan-Sheng; Xu, Rui; Luu, Norman S.
Efficient energy storage systems based on lithium-ion batteries represent a critical technology across many sectors including consumer electronics, electrified transportation, and a smart grid accommodating intermittent renewable energy sources. Nanostructured electrode materials present compelling opportunities for high-performance lithium-ion batteries, but inherent problems related to the high surface area to volume ratios at the nanometer-scale have impeded their adoption for commercial applications. Here, we demonstrate a materials and processing platform that realizes high-performance nanostructured lithium manganese oxide (nano-LMO) spinel cathodes with conformal graphene coatings as a conductive additive. The resulting nanostructured composite cathodes concurrently resolve multiple problems that have plagued nanoparticle-basedmore » lithium-ion battery electrodes including low packing density, high additive content, and poor cycling stability. Moreover, this strategy enhances the intrinsic advantages of nano-LMO, resulting in extraordinary rate capability and low temperature performance. With 75% capacity retention at a 20C cycling rate at room temperature and nearly full capacity retention at -20 degrees C, this work advances lithium-ion battery technology into unprecedented regimes of operation.« less
One-pot, bioinspired coatings to reduce the flammability of flexible polyurethane foams.
Davis, Rick; Li, Yu-Chin; Gervasio, Michelle; Luu, Jason; Kim, Yeon Seok
2015-03-25
In this manuscript, natural materials were combined into a single "pot" to produce flexible, highly fire resistant, and bioinspired coatings on flexible polyurethane foam (PUF). In one step, PUF was coated with a fire protective layer constructed of a polysaccharide binder (starch or agar), a boron fire retardant (boric acid or derivative), and a dirt char former (montmorillonite clay). Nearly all coatings produced a 63% reduction in a critical flammability value, the peak heat release rate (PHRR). One formulation produced a 75% reduction in PHRR. This technology was validated in full-scale furniture fire tests, where a 75% reduction in PHRR was measured. At these PHRR values, this technology could reduce the fire threat of furniture from significant fire damage in and beyond the room of fire origin to being contained to the burning furniture. This flammability reduction was caused by three mechanisms-the gas-phase and condensed-phase processes of the boron fire retardant and the condensed-phase process of the clay. We describe the one-pot coating process and the impact of the coating composition on flammability.
Hydrogenated Nano-/Micro-Crystalline Silicon Thin-Films for Thermoelectrics
NASA Astrophysics Data System (ADS)
Acosta, E.; Wight, N. M.; Smirnov, V.; Buckman, J.; Bennett, N. S.
2018-06-01
Thermoelectric technology has not yet been able to reach full-scale market penetration partly because most commercial materials employed are scarce/costly, environmentally unfriendly and in addition provide low conversion efficiency. The necessity to tackle some of these hurdles leads us to investigate the suitability of n-type hydrogenated microcrystalline silicon (μc-Si: H) in the fabrication of thermoelectric devices, produced by plasma enhanced chemical vapour deposition (PECVD), which is a mature process of proven scalability. This study reports an approach to optimise the thermoelectric power factor (PF) by varying the dopant concentration by means of post-annealing without impacting film morphology, at least for temperatures below 550°C. Results show an improvement in PF of more than 80%, which is driven by a noticeable increase of carrier mobility and Seebeck coefficient in spite of a reduction in carrier concentration. A PF of 2.08 × 10-4 W/mK2 at room temperature is reported for n-type films of 1 μm thickness, which is in line with the best values reported in recent literature for similar structures.
Chen, Kan-Sheng; Xu, Rui; Luu, Norman S; Secor, Ethan B; Hamamoto, Koichi; Li, Qianqian; Kim, Soo; Sangwan, Vinod K; Balla, Itamar; Guiney, Linda M; Seo, Jung-Woo T; Yu, Xiankai; Liu, Weiwei; Wu, Jinsong; Wolverton, Chris; Dravid, Vinayak P; Barnett, Scott A; Lu, Jun; Amine, Khalil; Hersam, Mark C
2017-04-12
Efficient energy storage systems based on lithium-ion batteries represent a critical technology across many sectors including consumer electronics, electrified transportation, and a smart grid accommodating intermittent renewable energy sources. Nanostructured electrode materials present compelling opportunities for high-performance lithium-ion batteries, but inherent problems related to the high surface area to volume ratios at the nanometer-scale have impeded their adoption for commercial applications. Here, we demonstrate a materials and processing platform that realizes high-performance nanostructured lithium manganese oxide (nano-LMO) spinel cathodes with conformal graphene coatings as a conductive additive. The resulting nanostructured composite cathodes concurrently resolve multiple problems that have plagued nanoparticle-based lithium-ion battery electrodes including low packing density, high additive content, and poor cycling stability. Moreover, this strategy enhances the intrinsic advantages of nano-LMO, resulting in extraordinary rate capability and low temperature performance. With 75% capacity retention at a 20C cycling rate at room temperature and nearly full capacity retention at -20 °C, this work advances lithium-ion battery technology into unprecedented regimes of operation.
Hydrogenated Nano-/Micro-Crystalline Silicon Thin-Films for Thermoelectrics
NASA Astrophysics Data System (ADS)
Acosta, E.; Wight, N. M.; Smirnov, V.; Buckman, J.; Bennett, N. S.
2017-11-01
Thermoelectric technology has not yet been able to reach full-scale market penetration partly because most commercial materials employed are scarce/costly, environmentally unfriendly and in addition provide low conversion efficiency. The necessity to tackle some of these hurdles leads us to investigate the suitability of n-type hydrogenated microcrystalline silicon (μc-Si: H) in the fabrication of thermoelectric devices, produced by plasma enhanced chemical vapour deposition (PECVD), which is a mature process of proven scalability. This study reports an approach to optimise the thermoelectric power factor (PF) by varying the dopant concentration by means of post-annealing without impacting film morphology, at least for temperatures below 550°C. Results show an improvement in PF of more than 80%, which is driven by a noticeable increase of carrier mobility and Seebeck coefficient in spite of a reduction in carrier concentration. A PF of 2.08 × 10-4 W/mK2 at room temperature is reported for n-type films of 1 μm thickness, which is in line with the best values reported in recent literature for similar structures.
ERIC Educational Resources Information Center
Alrashid, Tareq M.; Barker, James A.; Christian, Brian S.; Cox, Steven C.; Rabne, Michael W.; Slotta, Elizabeth A.; Upthegrove, Luella R.
1998-01-01
Describes Case Western Reserve University's (CWRU's) digital library project that examines the networked delivery of full-text materials and high-quality images to provide students excellent supplemental instructional resources delivered directly to their dormitory rooms. Reviews intellectual property (IP) management requirements and describes…
30 CFR 74.8 - Measurement, accuracy, and reliability requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... concentration, as defined by the relative standard deviation of the distribution of measurements. The relative standard deviation shall be less than 0.1275 without bias for both full-shift measurements of 8 hours or... Standards, Regulations, and Variances, 1100 Wilson Boulevard, Room 2350, Arlington, Virginia 22209-3939...
49 CFR 1001.1 - Records available from the Board.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Board Administrative Issuances. (b) The following records, so-called “reading room” documents, are... or date of issuance and are available for viewing and downloading from the Board's Electronic Reading Room at www.stb.dot.gov, the Board's website. Final decisions are maintained in a database that is full...
77 FR 37553 - Access Authorization Fees
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... PDR: You may examine and purchase copies of public documents at the NRC's PDR, Room O1-F21, One White... authorization. The formula for calculating fees remains based on current Office of Personnel Management (OPM) billing rates for personnel background investigations. The NRC designed the formula to recover the full...
78 FR 27342 - Radio Broadcasting Services; Moran, Texas
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-10
... instructions for submitting comments and additional information of the rulemaking process, see the..., adopted April 24, 2013, and released April 26, 2013. The full text of this Commission decision is... (Room CY-A257), 445 12th Street SW., Washington, DC 20554. The complete text of this decision may also...
Space Guidelines for Libraries.
ERIC Educational Resources Information Center
Wisconsin Coordinating Committee for Higher Education, Madison.
The following guidelines are recommended: stack space--for each 10 volumes, one square foot of space; reading room--25 square feet per station x 20% of the total undergraduate population; carrel space--25% of the graduate enrollment x 45 square feet; office and auxilliary space--135 square feet x full time equivalent staff. (NI)
The Establishment of a New Friction Stir Welding Process Development Facility at NASA/MSFC
NASA Technical Reports Server (NTRS)
Vaughn, Timothy P.
2012-01-01
The primary objective of full scale development is to mitigate scale-up issues before the vehicle ever reaches production and verify assembly design models. Only at full scale can the true challenges associated with production be identified and dealt with. Also, only at full scale can the delta shift between lab and subscale hardware manufacture and assembly be assessed.
van Det, M J; Meijerink, W J H J; Hoff, C; van Veelen, M A; Pierie, J P E N
2008-11-01
With the expanding implementation of minimally invasive surgery, the operating team is confronted with challenges in the field of ergonomics. Visual feedback is derived from a monitor placed outside the operating field. This crossover trial was conducted to evaluate and compare neck posture in relation to monitor position in a dedicated minimally invasive surgery (MIS) suite and a conventional operating room. Assessment of the neck was conducted for 16 surgeons, assisting surgeons, and scrub nurses performing a laparoscopic cholecystectomy in both types of operating room. Flexion and rotation of the cervical spine were measured intraoperatively using a video analysis system. A two-question visual analog scale (VAS) questionnaire was used to evaluate posture in relation to the monitor position. Neck rotation was significantly reduced in the MIS suite for the surgeon (p = 0.018) and the assisting surgeon (p < 0.001). Neck flexion was significantly improved in the MIS suite for the surgeon (p < 0.001) and the scrub nurse (p = 0.018). On the questionnaire, the operating room team scored their posture significantly higher in the MIS suite and also indicated fewer musculoskeletal complaints. The ergonomic quality of the neck posture is significantly improved in the MIS suite for the entire operating room team.
Dong, Wenjun; Huang, Huandi; Zhu, Yanjun; Li, Xiaoyun; Wang, Xuebin; Li, Chaorong; Chen, Benyong; Wang, Ge; Shi, Zhan
2012-10-26
A simple chemical solution route for the synthesis of large-scale high-quality Ag nanoparticle functionalized molybdenum oxide nanowire at room temperature has been developed. In the synthesis, the protonated amine was intercalated into the molybdenum bronze layers to reduce the electrostatic force of the lamellar structures, and then the Ag nanoparticle functionalized long nanowires could be easily induced by a redox reaction between a molybdenum oxide-amine intermediate and Ag(+) at room temperature. The intercalation lamellar structures improved the nucleation and growth of the Ag nanoparticles, with the result that uniform Ag nanoparticles occurred on the surface of the MoO(3) nanowire. In this way Ag nanoparticles with average sizes of around 6 nm, and high-purity nanowires with mean diameter of around 50 nm and with typical lengths of several tens to hundreds of micrometers were produced. The heteronanostructured nanowires were intricately and inseparably connected to each other with hydrogen bonds and/or bridge oxygen atoms and packed together, forming a paper-like porous network film. The Ag-MoO(3) nanowire film performs a promoted catalytic property for the epoxidation of cis-cyclooctene, and the heteronanostructured nanowire film sensor shows excellent sensing performance to hydrogen and oxygen at room temperature.
Yang, Manman; Wang, Zongyuan; Wang, Wei; Liu, Chang-Jun
2014-01-01
Argon glow discharge has been employed as a cheap, environmentally friendly, and convenient electron source for simultaneous reduction of HAuCl4 and PdCl2 on the anodic aluminum oxide (AAO) substrate. The thermal imaging confirms that the synthesis is operated at room temperature. The reduction is conducted with a short time (30 min) under the pressure of approximately 100 Pa. This room-temperature electron reduction operates in a dry way and requires neither hydrogen nor extra heating nor chemical reducing agent. The analyses using X-ray photoelectron spectroscopy (XPS) confirm all the metallic ions have been reduced. The characterization with X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM) shows that AuPd alloyed nanoparticles are formed. There also exist some highly dispersed Au and Pd monometallic particles that cannot be detected by XRD and transmission electron microscopy (TEM) because of their small particle sizes. The observed AuPd alloyed nanoparticles are spherical with an average size of 14 nm. No core-shell structure can be observed. The room-temperature electron reduction can be operated in a larger scale. It is an easy way for the synthesis of AuPd alloyed nanoparticles.
Energy-filtered cold electron transport at room temperature.
Bhadrachalam, Pradeep; Subramanian, Ramkumar; Ray, Vishva; Ma, Liang-Chieh; Wang, Weichao; Kim, Jiyoung; Cho, Kyeongjae; Koh, Seong Jin
2014-09-10
Fermi-Dirac electron thermal excitation is an intrinsic phenomenon that limits functionality of various electron systems. Efforts to manipulate electron thermal excitation have been successful when the entire system is cooled to cryogenic temperatures, typically <1 K. Here we show that electron thermal excitation can be effectively suppressed at room temperature, and energy-suppressed electrons, whose energy distribution corresponds to an effective electron temperature of ~45 K, can be transported throughout device components without external cooling. This is accomplished using a discrete level of a quantum well, which filters out thermally excited electrons and permits only energy-suppressed electrons to participate in electron transport. The quantum well (~2 nm of Cr2O3) is formed between source (Cr) and tunnelling barrier (SiO2) in a double-barrier-tunnelling-junction structure having a quantum dot as the central island. Cold electron transport is detected from extremely narrow differential conductance peaks in electron tunnelling through CdSe quantum dots, with full widths at half maximum of only ~15 mV at room temperature.
Amorphization of nanocrystalline 3C-SiC irradiated with Si+ ions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Weilin; Wang, H.; Zhang, Yanwen
2010-01-01
Irradiation induced amorphization in nanocrystalline and single crystal 3C-SiC has been studied using 1 MeV Si+ ions under identical irradiation conditions at room temperature and 400 K. The disordering behavior has been characterized using in-situ ion channeling and ex-situ x-ray diffraction methods. The results show that, compared to single crystal 3C-SiC, full amorphization of small 3C-SiC grains (~3.8 nm in size) at room temperature occurs at a slightly lower dose. Grain size decreases with increasing dose until a fully amorphized state is attained. The amorphization dose increases at 400 K relative to room temperature. However, at 400 K, the dosemore » for amorphization for 2.0 nm grains is about a factor of 4 and 8 smaller than for 3.0 nm grains and bulk single crystal 3C-SiC, respectively. The behavior is attributed to the dominance of defect-stimulated interfacial amorphization.« less
Connelly, Stephanie; Shin, Seung G.; Dillon, Robert J.; Ijaz, Umer Z.; Quince, Christopher; Sloan, William T.; Collins, Gavin
2017-01-01
Studies investigating the feasibility of new, or improved, biotechnologies, such as wastewater treatment digesters, inevitably start with laboratory-scale trials. However, it is rarely determined whether laboratory-scale results reflect full-scale performance or microbial ecology. The Expanded Granular Sludge Bed (EGSB) bioreactor, which is a high-rate anaerobic digester configuration, was used as a model to address that knowledge gap in this study. Two laboratory-scale idealizations of the EGSB—a one-dimensional and a three- dimensional scale-down of a full-scale design—were built and operated in triplicate under near-identical conditions to a full-scale EGSB. The laboratory-scale bioreactors were seeded using biomass obtained from the full-scale bioreactor, and, spent water from the distillation of whisky from maize was applied as substrate at both scales. Over 70 days, bioreactor performance, microbial ecology, and microbial community physiology were monitored at various depths in the sludge-beds using 16S rRNA gene sequencing (V4 region), specific methanogenic activity (SMA) assays, and a range of physical and chemical monitoring methods. SMA assays indicated dominance of the hydrogenotrophic pathway at full-scale whilst a more balanced activity profile developed during the laboratory-scale trials. At each scale, Methanobacterium was the dominant methanogenic genus present. Bioreactor performance overall was better at laboratory-scale than full-scale. We observed that bioreactor design at laboratory-scale significantly influenced spatial distribution of microbial community physiology and taxonomy in the bioreactor sludge-bed, with 1-D bioreactor types promoting stratification of each. In the 1-D laboratory bioreactors, increased abundance of Firmicutes was associated with both granule position in the sludge bed and increased activity against acetate and ethanol as substrates. We further observed that stratification in the sludge-bed in 1-D laboratory-scale bioreactors was associated with increased richness in the underlying microbial community at species (OTU) level and improved overall performance. PMID:28507535
Temperature evolution of the structural properties of monodomain ferroelectric thin film
NASA Astrophysics Data System (ADS)
Janolin, Pierre-Eymeric; Le Marrec, Françoise; Chevreul, Jacques; Dkhil, Brahim
2007-05-01
The structural evolution of epitaxial monodomain (only 180° domains) ferroelectric PbTiO3 thin film has been investigated, using high-resolution, temperature-dependent, x-ray diffraction. The full set of lattice parameters was obtained from room temperature up to 850K. It allowed the calculation of the different strains stored in the film at room temperature, underlying the difference between the mechanical strain and the misfit strain. The evolution of the misfit strain as a function of temperature was also calculated and was found to be consistent with the theoretical temperature-misfit strain phase diagram. These data strongly suggest that the film remains ferroelectric and tetragonal up to 940K.
14. NBS REMOTE MANIPULATOR SIMULATOR (RMS) CONTROL ROOM. THE RMS ...
14. NBS REMOTE MANIPULATOR SIMULATOR (RMS) CONTROL ROOM. THE RMS CONTROL PANEL IS IDENTICAL TO THE SHUTTLE ORBITER AFT FLIGHT DECK WITH ALL RMS SWITCHES AND CONTROL KNOBS FOR INVOKING ANY POSSIBLE FLIGHT OPERATIONAL MODE. THIS INCLUDES ALL COMPUTER AIDED OPERATIONAL MODES, AS WELL AS FULL MANUAL MODE. THE MONITORS IN THE AFT FLIGHT DECK WINDOWS AND THE GLASSES THE OPERATOR WEARS PROVIDE A 3-D VIDEO PICTURE TO AID THE OPERATOR WITH DEPTH PERCEPTION WHILE OPERATING THE ARM. THIS IS REQUIRED BECAUSE THE RMS OPERATOR CANNOT VIEW RMS MOVEMENTS IN THE WATER WHILE AT THE CONTROL PANEL. - Marshall Space Flight Center, Neutral Buoyancy Simulator Facility, Rideout Road, Huntsville, Madison County, AL
NASA Astrophysics Data System (ADS)
Marchewka, M. K.; Pietraszko, A.
2008-02-01
The piperazinium bis(4-hydroxybenzenesulphonate) crystallizes from water solution at room temperature in P2 1/ c space group of monoclinic system. The crystals are built up of doubly protonated piperazinium cations and ionized 4-hydroxybenzenesulphonate anions that interact through weak hydrogen bonds of O-H⋯O and N-H⋯O type. Mutual orientation of anions is determined by non-conventional hydrogen bonds of C-H⋯π type. Room temperature powder FT IR and FT Raman measurements were carried out. The vibrational spectra are in full agreement with the structure obtained from X-ray crystallography. The big single crystals of the title salt can be grown.
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
Education, Wechler's Full Scale IQ and "g."
ERIC Educational Resources Information Center
Colom, Roberto; Abad, Francisco J.; Garcia, Luis F.; Juan-Espinosa, Manuel
2002-01-01
Investigated whether average Full Scale IQ (FSIQ) differences can be attributed to "g" using the Spanish standardization sample of the Wechsler Adult Intelligence Scale III (WAIS III) (n=703 females and 666 men). Results support the conclusion that WAIS III FSIQ does not directly or exclusively measure "g" across the full range…
5 CFR 532.233 - Preparation for full-scale wage surveys.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Preparation for full-scale wage surveys... REGULATIONS PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532.233 Preparation for full-scale wage... the local wage survey committee. (e) Selection and appointment of data collectors. (1) The local wage...
Integrated Resilient Aircraft Control Project Full Scale Flight Validation
NASA Technical Reports Server (NTRS)
Bosworth, John T.
2009-01-01
Objective: Provide validation of adaptive control law concepts through full scale flight evaluation. Technical Approach: a) Engage failure mode - destabilizing or frozen surface. b) Perform formation flight and air-to-air tracking tasks. Evaluate adaptive algorithm: a) Stability metrics. b) Model following metrics. Full scale flight testing provides an ability to validate different adaptive flight control approaches. Full scale flight testing adds credence to NASA's research efforts. A sustained research effort is required to remove the road blocks and provide adaptive control as a viable design solution for increased aircraft resilience.
Calderón-Vallejo, Luisa Fernanda; Andrade, Cynthia Franco; Manjate, Elias Sete; Madera-Parra, Carlos Arturo; von Sperling, Marcos
2015-01-01
This study investigated the performance of sludge drying reed beds (SDRB) at full- and pilot-scale treating sludge from septic tanks in the city of Belo Horizonte, Brazil. The treatment units, planted with Cynodon spp., were based on an adaptation of the first-stage of the French vertical-flow constructed wetland, originally developed for treating sewage. Two different operational phases were investigated; in the first one, the full-scale unit was used together with six pilot-scale columns in order to test different feeding strategies. For the second phase, only the full-scale unit was used, including a recirculation of the filtered effluent (percolate) to one of the units of the French vertical wetland. Sludge application was done once a week emptying a full truck, during 25 weeks. The sludge was predominantly diluted, leading to low solids loading rates (median values of 18 kgTS m(-2) year(-1)). Chemical oxygen demand removal efficiency in the full-scale unit was reasonable (median of 71%), but the total solids removal was only moderate (median of 44%) in the full-scale unit without recirculation. Recirculation did not bring substantial improvements in the overall performance. The other loading conditions implemented in the pilot columns also did not show statistically different performances.
Geometry and Reynolds-Number Scaling on an Iced Business-Jet Wing
NASA Technical Reports Server (NTRS)
Lee, Sam; Ratvasky, Thomas P.; Thacker, Michael; Barnhart, Billy P.
2005-01-01
A study was conducted to develop a method to scale the effect of ice accretion on a full-scale business jet wing model to a 1/12-scale model at greatly reduced Reynolds number. Full-scale, 5/12-scale, and 1/12-scale models of identical airfoil section were used in this study. Three types of ice accretion were studied: 22.5-minute ice protection system failure shape, 2-minute initial ice roughness, and a runback shape that forms downstream of a thermal anti-ice system. The results showed that the 22.5-minute failure shape could be scaled from full-scale to 1/12-scale through simple geometric scaling. The 2-minute roughness shape could be scaled by choosing an appropriate grit size. The runback ice shape exhibited greater Reynolds number effects and could not be scaled by simple geometric scaling of the ice shape.
The Relative Utility of the Shipley-Hartford Scale: Prediction of WAIS-R IQ.
ERIC Educational Resources Information Center
Heinemann, Allen W.; And Others
1985-01-01
Examined Shipley-Hartford Scale effectiveness in predicting Wechsler Adult Intelligence Scale-Revised Full Scale intelligence quotients (IQ) in hospital patients (N=156). Analyses revealed overestimation of below average Full Scale IQs, underestimation of above average IQs. Advanced age was associated with low conceptual quotients, suggesting that…
Simulated life-threatening emergency during robot-assisted surgery.
Huser, Anna-Sophia; Müller, Dirk; Brunkhorst, Violeta; Kannisto, Päivi; Musch, Michael; Kröpfl, Darko; Groeben, Harald
2014-06-01
With the increasing use of robot-assisted techniques for urologic and gynecologic surgery in patients with severe comorbidities, the risk of a critical incidence during surgery increases. Due to limited access to the patient the start of effective measures to treat a life-threatening emergency could be delayed. Therefore, we tested the management of an acute emergency in an operating room setting with a full-size simulator in six complete teams. A full-size simulator (ISTAN, Meti, CA), modified to hold five trocars, was placed in a regular operating room and connected to a robotic system. Six teams (each with three nurses, one anesthesiologist, two urologists or gynecologists) were introduced to the scenario. Subsequently, myocardial fibrillation occurred. Time to first chest compression, removal of the robot, first defibrillation, and stabilization of circulation were obtained. After 7 weeks the simulation was repeated. The time to the start of chest compressions, removal of the robotic system, and first defibrillation were significantly improved at the second simulation. Time for restoration of stable circulation was improved from 417 ± 125 seconds to 224 ± 37 seconds (P=0.0054). Unexpected delays occurred during the first simulation because trocars had been removed from the patient but not from the robot, thus preventing the robot to be moved. Following proper training, resuscitation can be started within seconds. A repetition of the simulation significantly improved time for all steps of resuscitation. An emergency simulation of a multidisciplinary team in a real operating room setting can be strongly recommended.
Direct synthesis of BiCuChO-type oxychalcogenides by mechanical alloying
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pele, Vincent; Barreteau, Celine; CNRS, Orsay F-91405
2013-07-15
We report on the direct synthesis of BiCuChO based materials by mechanical alloying (Ch=Se, Te). We show that contrary to the synthesis paths used in the previous reports dealing with this family of materials, which use costly annealings in closed silica tubes under controlled atmosphere, this new synthesis route enables the synthesis of pure phase materials at room temperature under air, with reasonable milling time. This synthesis procedure is easily scalable for large scale applications. - Highlights: • Phase pure BiCuSeO doped and undoped prepared by mechanical alloying. • Synthesis performed under air at room temperature. • Electrical properties similarmore » to that of samples synthesized by a classical path.« less
Room-temperature ionic liquids: slow dynamics, viscosity, and the red edge effect.
Hu, Zhonghan; Margulis, Claudio J
2007-11-01
Ionic liquids (ILs) have recently attracted significant attention from academic and industrial sources. This is because, while their vapor pressures are negligible, many of them are liquids at room temperature and can dissolve a wide range of polar and nonpolar organic and inorganic molecules. In this Account, we discuss the progress of our laboratory in understanding the dynamics, spectroscopy, and fluid dynamics of selected imidazolium-based ILs using computational and analytical tools that we have recently developed. Our results indicate that the red edge effect, the non-Newtonian behavior, and the existence of locally heterogeneous environments on a time scale relevant to chemical and photochemical reactivity are closely linked to the viscosity and highly structured character of these liquids.
NASA Astrophysics Data System (ADS)
Royal, Kevin; Crawford, Christopher; Mullins, Andrew; Porter, Greg; Blanton, Hunter; Johnstone, Connor; Kistler, Ben; Olivera, Daniela
2017-09-01
The search for the electric dipole moment of the neutron requires the ambient magnetic field to be on the pT scale which is accomplished with large magnetic shielding rooms. These rooms are fitted with large mu-metal sheets to allow for passive cancellation of background magnetic fields. Active shielding technology cannot uniformly cancel background magnetic fields. These issues can be remedied by combining the methods into a hybrid system. The design used is composed of panels that have an active layer of cancellation between two sheets of mu-metal. The panels form a cube and draw in magnetic fields perpendicular to the surface which can then be reduced using active shielding. This work is supported by the Department of Energy under Contract DE-SC0008107.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hitchcock, D.; Colon-Mercado, H.; Krentz, T.
Hydrogen isotope separation is critical to the DOE’s mission in environmental remediation and nuclear nonproliferation. Isotope separation is also a critical technology for the NNSA, and the ability to perform the separations at room temperature with a relatively small amount of power and space would be a major advancement for their respective missions. Recent work has shown that 2-D materials such as graphene and hexagonal boron nitride can act as an isotopic sieve at room temperature; efficiently separating hydrogen isotopes in water with reported separation ratios of 10:1 for hydrogen: deuterium separation for a single pass. The work performed heremore » suggests that this technique has merit, and furthermore, we are investigating optimization and scale up of the required 2-D material based membranes.« less
Zhuo, Fangping; Li, Qiang; Gao, Jinghan; Ji, Yongjie; Yan, Qingfeng; Zhang, Yiling; Wu, Hong-Hui; Xi, Xiao-Qing; Chu, Xiangcheng; Cao, Wenwu
2018-04-11
(Pb 0.97 La 0.02 )(Zr x Sn 0.94- x Ti 0.06 )O 3 (PLZST) antiferroelectric ceramics with x = 0.75-0.90 have been fabricated and found to be a novel electrocaloric material system with a giant negative electrocaloric effect (Δ T = -11.5 K) and a large electrocaloric strength (|Δ T/Δ E| = 0.105 K cm kV -1 ) near room temperature. Additionally, the PLZST antiferroelectric ceramic also exhibits a large positive electrocaloric effect around the Curie temperature. The giant negative effect and the coexistence of both positive and negative electrocaloric effects in one material indicate a promising possibility to develop mid- to large-scale solid-state cooling devices with high efficiency.
Plasticity performance of Al 0.5 CoCrCuFeNi high-entropy alloys under nanoindentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Li-ping; Chen, Shu-ying; Ren, Jing-li
2017-04-01
The statistical and dynamic behaviors of the displacement-load curves of a high-entropy alloy, Al0.5 CoCrCuFeNi, were analyzed for the nanoindentation performed at two temperatures. Critical behavior of serrations at room temperature and chaotic flows at 200 °C were detected. These results are attributed to the interaction among a large number of slip bands. For the nanoindentation at room temperature, recurrent partial events between slip bands introduce a hierarchy of length scales, leading to a critical state. For the nanoindentation at 200 °C, there is no spatial interference between two slip bands, which is corresponding to the evolution of separated trajectorymore » of chaotic behavior« less
Assessment of mood: guides for clinicians.
Furukawa, Toshi A
2010-06-01
This article is one of the series of review articles aiming to present a convenient guideline for practicing clinicians in their selection of scales for clinical and research purposes. This article focuses on assessment scales for mood (depression, mania). After reviewing the basic principles of clinical psychometrics, we present a selective review of representative scales measuring depressed or manic mood. We reviewed and reported on reliability, validity, interpretability, and feasibility of the following rating scales: Patient Health Questionnaire-9 (PHQ-9), K6, Beck Depression Inventory II (BDI-II), and Quick Inventory of Depressive Symptomatology Self-Report (QIDS-SR) as self-report scales for depressed mood; Hamilton Rating Scale for Depression (HAM-D) and Montgomery-Asberg Depression Rating Scale (MADRS) as clinician-administered measure for depression; and Young Mania Rating Scale (YMRS) as a clinician-administered instrument for mania. Although the rating scales for mood represent a well-trodden terrain, this brief review of the most frequently used scales in the literature revealed there is still some room for improvement and for further research, especially with regard to their clinical interpretability. Copyright 2010 Elsevier Inc. All rights reserved.
An Analysis of Model Scale Data Transformation to Full Scale Flight Using Chevron Nozzles
NASA Technical Reports Server (NTRS)
Brown, Clifford; Bridges, James
2003-01-01
Ground-based model scale aeroacoustic data is frequently used to predict the results of flight tests while saving time and money. The value of a model scale test is therefore dependent on how well the data can be transformed to the full scale conditions. In the spring of 2000, a model scale test was conducted to prove the value of chevron nozzles as a noise reduction device for turbojet applications. The chevron nozzle reduced noise by 2 EPNdB at an engine pressure ratio of 2.3 compared to that of the standard conic nozzle. This result led to a full scale flyover test in the spring of 2001 to verify these results. The flyover test confirmed the 2 EPNdB reduction predicted by the model scale test one year earlier. However, further analysis of the data revealed that the spectra and directivity, both on an OASPL and PNL basis, do not agree in either shape or absolute level. This paper explores these differences in an effort to improve the data transformation from model scale to full scale.
Living Room vs. Concert Hall: Patterns of Music Consumption in Flanders
ERIC Educational Resources Information Center
Roose, Henk; Stichele, Alexander Vander
2010-01-01
In this article we probe the interplay between public and private music consumption using a large-scale survey of the Flemish population in Belgium. We analyze whether public and private music consumption have different correlates and to what extent there is convergence between the genres that people listen to at home and at concerts. Results show…
Movement and Learning: Integrating Physical Activity into the Classroom
ERIC Educational Resources Information Center
Reeves, Emily; Miller, Stacia; Chavez, Crystal
2016-01-01
We know the benefits of physical activity, and yet recess and physical education classes are being cut or scaled back to make room for meeting academic standards. Is cutting recess and physical education really benefiting academics? A look at some recent studies suggests that it is not. Integrating physical activity into the classroom may increase…
2013 Materials Research Society Fall Meeting
2014-06-18
metamaterials. Highlights included reports on significant breakthroughs in metasurface design and implementation, as well as important advances in...Mark Brongersma, Device Applications of Metafilms and Metasurfaces Monday, 8:30AM—Room 209, Hynes Metafilms and Metasurfaces have much potential to...patterning the constituent layers at length scales well below the wavelength of light. The resulting metafilms and metasurfaces offer opportunities
The Effect of Academic Stress upon the Anxiety and Depression Levels of Gifted High-School Students.
ERIC Educational Resources Information Center
Yadusky-Holahan, Mary; Holahan, William
1983-01-01
Scores of 60 gifted 12th graders on scales of anxiety and depression supported the hypotheses that depression was significantly higher during the second testing than during baseline. Students in single rooms reported more age specific problems. Implications include the need to promote greater social interaction in residence halls. (CL)
A Computer-Controlled Classroom Model of an Atomic Force Microscope
ERIC Educational Resources Information Center
Engstrom, Tyler A.; Johnson, Matthew M.; Eklund, Peter C.; Russin, Timothy J.
2015-01-01
The concept of "seeing by feeling" as a way to circumvent limitations on sight is universal on the macroscopic scale--reading Braille, feeling one's way around a dark room, etc. The development of the atomic force microscope (AFM) in 1986 extended this concept to imaging in the nanoscale. While there are classroom demonstrations that use…
Designs for Living and Learning: Transforming Early Childhood Environments, Second Edition
ERIC Educational Resources Information Center
Carter, Margie; Curtis, Deb
2015-01-01
You likely have dreams for your early childhood environment that are greater than rating scales, regulations, and room arrangements. "Designs for Living and Learning" has been a favorite resource among educators and caregivers for more than a decade, and this new edition is packed with even more ideas that can be used as you create…
Time-Lapse Videos for Physics Education: Specific Examples
ERIC Educational Resources Information Center
Vollmer, Michael; Möllmann, Klaus-Peter
2018-01-01
There are many physics experiments with long time scales such that they are usually neither shown in the physics class room nor in student labs. However, they can be easily recorded with time-lapse cameras and the respective time-lapse videos allow qualitative and/or quantitative analysis of the underlying physics. Here, we present some examples…
Center of parcel with mosaics. Mosaics consist of everyday throwaway ...
Center of parcel with mosaics. Mosaics consist of everyday throwaway objects of all kinds set in concrete mortar on ground. Leaning Tower of Bottle Village in front of Rumpus Room primary façade with 12' scale (in tenths). Camera facing north. - Grandma Prisbrey's Bottle Village, 4595 Cochran Street, Simi Valley, Ventura County, CA
Dedy, Nicolas J; Szasz, Peter; Louridas, Marisa; Bonrath, Esther M; Husslein, Heinrich; Grantcharov, Teodor P
2015-06-01
Nontechnical skills are critical for patient safety in the operating room (OR). As a result, regulatory bodies for accreditation and certification have mandated the integration of these competencies into postgraduate education. A generally accepted approach to the in-training assessment of nontechnical skills, however, is lacking. The goal of the present study was to develop an evidence-based and reliable tool for the in-training assessment of residents' nontechnical performance in the OR. The Objective Structured Assessment of Nontechnical Skills tool was designed as a 5-point global rating scale with descriptive anchors for each item, based on existing evidence-based frameworks of nontechnical skills, as well as resident training requirements. The tool was piloted on scripted videos and refined in an iterative process. The final version was used to rate residents' performance in recorded OR crisis simulations and during live observations in the OR. A total of 37 simulations and 10 live procedures were rated. Interrater agreement was good for total mean scores, both in simulation and in the real OR, with intraclass correlation coefficients >0.90 in all settings for average and single measures. Internal consistency of the scale was high (Cronbach's alpha = 0.80). The Objective Structured Assessment of Nontechnical Skills global rating scale was developed as an evidence-based tool for the in-training assessment of residents' nontechnical performance in the OR. Unique descriptive anchors allow for a criterion-referenced assessment of performance. Good reliability was demonstrated in different settings, supporting applications in research and education. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Xu, Chen; Ahmad, Zeeshan; Aryanfar, Asghar; Viswanathan, Venkatasubramanian; Greer, Julia R.
2017-01-01
Most next-generation Li ion battery chemistries require a functioning lithium metal (Li) anode. However, its application in secondary batteries has been inhibited because of uncontrollable dendrite growth during cycling. Mechanical suppression of dendrite growth through solid polymer electrolytes (SPEs) or through robust separators has shown the most potential for alleviating this problem. Studies of the mechanical behavior of Li at any length scale and temperature are limited because of its extreme reactivity, which renders sample preparation, transfer, microstructure characterization, and mechanical testing extremely challenging. We conduct nanomechanical experiments in an in situ scanning electron microscope and show that micrometer-sized Li attains extremely high strengths of 105 MPa at room temperature and of 35 MPa at 90 °C. We demonstrate that single-crystalline Li exhibits a power-law size effect at the micrometer and submicrometer length scales, with the strengthening exponent of -0.68 at room temperature and of -1.00 at 90 °C. We also report the elastic and shear moduli as a function of crystallographic orientation gleaned from experiments and first-principles calculations, which show a high level of anisotropy up to the melting point, where the elastic and shear moduli vary by a factor of ˜4 between the stiffest and most compliant orientations. The emergence of such high strengths in small-scale Li and sensitivity of this metal’s stiffness to crystallographic orientation help explain why the existing methods of dendrite suppression have been mainly unsuccessful and have significant implications for practical design of future-generation batteries.
Teamwork in the operating room: frontline perspectives among hospitals and operating room personnel.
Sexton, J Bryan; Makary, Martin A; Tersigni, Anthony R; Pryor, David; Hendrich, Ann; Thomas, Eric J; Holzmueller, Christine G; Knight, Andrew P; Wu, Yun; Pronovost, Peter J
2006-11-01
The Joint Commission on Accreditation of Healthcare Organizations is proposing that hospitals measure culture beginning in 2007. However, a reliable and widely used measurement tool for the operating room (OR) setting does not currently exist. OR personnel in 60 US hospitals were surveyed using the Safety Attitudes Questionnaire. The teamwork climate domain of the survey uses six items about difficulty speaking up, conflict resolution, physician-nurse collaboration, feeling supported by others, asking questions, and heeding nurse input. To justify grouping individual-level responses to a single score at each hospital OR level, the authors used a multilevel confirmatory factor analysis, intraclass correlations, within-group interrater reliability, and Cronbach's alpha. To detect differences at the hospital OR level and by caregiver type, the authors used multivariate analysis of variance (items) and analysis of variance (scale). The response rate was 77.1%. There was robust evidence for grouping individual-level respondents to the hospital OR level using the diverse set of statistical tests, e.g., Comparative Fit Index = 0.99, root mean squared error of approximation = 0.05, and acceptable intraclasss correlations, within-group interrater reliability values, and Cronbach's alpha = 0.79. Teamwork climate differed significantly by hospital (F59, 1,911 = 4.06, P < 0.001) and OR caregiver type (F4, 1,911 = 9.96, P < 0.001). Rigorous assessment of teamwork climate is possible using this psychometrically sound teamwork climate scale. This tool and initial benchmarks allow others to compare their teamwork climate to national means, in an effort to focus more on what excellent surgical teams do well.
The Pressure Available for Ground Cooling in Front of the Cowling of Air-cooled Airplane Engines
NASA Technical Reports Server (NTRS)
Stickle, George W; Joyner, Upshur T
1938-01-01
A study was made of the factors affecting the pressure available for ground cooling in front of a cowling. Most of the results presented were obtained with a set-up that was about one-third full scale. A number of isolated tests on four full-scale airplanes were made to determine the general applicability of the model results. The full-scale tests indicated that the model results may be applied qualitatively to full-scale design and quantitatively as a first approximation of the front pressure available for ground cooling.
Psychometric Testing of the Persian Version of the Perceived Perioperative Competence Scale-Revised.
Ajorpaz, Neda Mirbagher; Tafreshi, Mansoureh Zagheri; Mohtashami, Jamileh; Zayeri, Farid; Rahemi, Zahra
2017-12-01
The clinical competence of nursing students in operating room (OR) is an important issue in nursing education. The purpose of this study was to evaluate the psychometric properties of the Persian Perceived Perioperative Competence Scale-Revised (PPCS-R) instrument. This cross-sectional study was conducted across 12 universities in Iran. The psychometric properties and factor structure of the PPCS-R for OR students was examined. Based on the results of factor analysis, seven items were removed from the original version of the scale. The fitness indices of the Persian scale include comparative fit index (CFI) = .90, goodness-of-fit-index (GFI) = .86, adjusted goodness-of-fit index (AGFI) = .90, normed fit index (NFI) = .84, and root mean square error of approximation (RMSEA) = .04. High validity and reliability indicated the scale's value for measuring perceived perioperative competence of Iranian OR students.
Costs at U.S. Educational Institutions, 1982/83.
ERIC Educational Resources Information Center
Boyan, Douglas R.
Costs at U.S. educational institutions for 1982-1983 are identified. A listing of monthly maintenance rates (MMR) by institution within each state covers room, board, incidentals, and makes no distinction between on-campus and off-campus living. The MMR data and guidelines for additional expenses are for the foreign student in typical full-time…
USDA-ARS?s Scientific Manuscript database
This study supplemented the National Air Emissions Monitoring Study (NAEMS) by making comprehensive measurements, over a full calendar year, of odor emissions from five swine and four dairy rooms/buildings (subset of the total number of buildings monitored for the NAEMS project). The measurements ma...
What Do Students Pay for College? Web Tables. NCES 2012-263
ERIC Educational Resources Information Center
Ginder, Scott; Mason, Marcinda
2012-01-01
The Integrated Postsecondary Education Data System (IPEDS) has long collected and reported data on tuition, required fees, and room and board charges for first-time, full-time undergraduate (FTFTUG) students. These charges, along with other miscellaneous expenses, constitute what is known as the "published price of attendance" or the…
The effect of mentoring on clinical perioperative competence in operating room nursing students.
Mirbagher Ajorpaz, Neda; Zagheri Tafreshi, Mansoureh; Mohtashami, Jamileh; Zayeri, Farid; Rahemi, Zahra
2016-05-01
The aim of this study was to investigate the effects of mentoring on the clinical perioperative competence of nursing operating room students in Iran. Mentoring is an essential part of clinical education, which has been studied in different populations of students. However, there is a need to assess its effectiveness in operating room students' competence. A randomised controlled trial was performed. Sixty nursing operating room students were randomly assigned to experimental and control groups. Both the control and experimental groups had routine training in the form of faculty supervision. The experimental group had an additional mentoring program. Using the Persian Perceived Perioperative Competence Scale-Revised, clinical competence was compared between the two groups, before and after the intervention. Using SPSS 19, descriptive and inferential statistics, including chi-square and t-tests, were conducted. In the experimental group, the difference between the mean scores of clinical competence before (19·43 ± 2·80) and after (27·86 ± 1·87) the intervention was significant (p ≤ 0·001). After intervention, the difference between the mean scores of the control (3·9 ± 0·15) and experimental (8·61 ± 0·68) groups was significant (p ≤ 0·003). Findings affirmed the positive effect of mentorship programmes on clinical competence in nursing operating room students. Mentoring is an effective method for preparing nursing students in practice. Health care systems may improve as a result of staff-student relationships that ultimately increase the quality care for patients. © 2016 John Wiley & Sons Ltd.
Speech adjustments for room acoustics and their effects on vocal effort
Bottalico, Pasquale
2016-01-01
Objectives The aims of the present study are: (1) to analyze the effects of the acoustical environment and the voice style on time dose (Dt_p,) and fundamental frequency (mean fo and standard deviation std_fo), while taking into account the effect of short term vocal fatigue; (2) to predict the self-reported vocal effort from the voice acoustical parameters. Methods Ten male and ten female subjects were recorded while reading a text in normal and loud styles, in three rooms - anechoic, semi-reverberant and reverberant –with and without acrylic glass panels 0.5 m from the mouth, which increased external auditory feedback. Subjects quantified how much effort was required to speak in each condition on a visual analogue scale after each task. Results (Aim1) In the loud style, Dt_p, fo and std_fo increased. The Dt_p was higher in the reverberant room compared to the other two rooms. Both genders tended to increase fo in less reverberant environments, while a more monotonous speech was produced in rooms with greater reverberation. All three voice parameters increased with short-term vocal fatigue. (Aim2) A model of the vocal effort to acoustic vocal parameters is proposed. The SPL (Sound Pressure Level) contributed to 66% of the variance explained by the model, followed by the fundamental frequency (30%) and the modulation in amplitude (4%). Conclusions The results provide insight into how voice acoustical parameters can predict vocal effort. In particular, it increased when SPL and fo increased and when the amplitude voice modulation (std_ΔSPL) decreased. PMID:28029555
40 CFR 86.1372-2007 - Measuring smoke emissions within the NTE zone.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Zero and full-scale (100 percent opacity) span shall be adjusted prior to testing. (3) Post test zero...-test and post-test checks shall be less than two percent of full-scale. (4) Opacimeter calibration and... adjusted prior to testing. (3) Post-test zero and full scale span checks shall be performed. For valid...
40 CFR 86.1372 - Measuring smoke emissions within the NTE zone.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Zero and full-scale (100 percent opacity) span shall be adjusted prior to testing. (3) Post test zero...-test and post-test checks shall be less than two percent of full-scale. (4) Opacimeter calibration and... adjusted prior to testing. (3) Post-test zero and full scale span checks shall be performed. For valid...
40 CFR 86.1372-2007 - Measuring smoke emissions within the NTE zone.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Zero and full-scale (100 percent opacity) span shall be adjusted prior to testing. (3) Post test zero...-test and post-test checks shall be less than two percent of full-scale. (4) Opacimeter calibration and... adjusted prior to testing. (3) Post-test zero and full scale span checks shall be performed. For valid...
40 CFR 86.1372-2007 - Measuring smoke emissions within the NTE zone.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Zero and full-scale (100 percent opacity) span shall be adjusted prior to testing. (3) Post test zero...-test and post-test checks shall be less than two percent of full-scale. (4) Opacimeter calibration and... adjusted prior to testing. (3) Post-test zero and full scale span checks shall be performed. For valid...
40 CFR 86.1372-2007 - Measuring smoke emissions within the NTE zone.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Zero and full-scale (100 percent opacity) span shall be adjusted prior to testing. (3) Post test zero...-test and post-test checks shall be less than two percent of full-scale. (4) Opacimeter calibration and... adjusted prior to testing. (3) Post-test zero and full scale span checks shall be performed. For valid...
Sadef, Yumna; Poulsen, Tjalfe Gorm; Bester, Kai
2015-06-01
Knowledge about the effects of oxygen concentration, nutrient availability and moisture content on removal of organic micro-pollutants during aerobic composting is at present very limited. Impact of oxygen concentration, readily available nitrogen content (NH4(+), NO3(-)), and moisture content on biological transformation of 15 key organic micro-pollutants during composting, was therefore investigated using bench-scale degradation experiments based on non-sterile compost samples, collected at full-scale composting facilities. In addition, the adequacy of bench-scale composting experiments for representing full-scale composting conditions, was investigated using micro-pollutant concentration measurements from both bench- and full-scale composting experiments. Results showed that lack of oxygen generally prevented transformation of organic micro-pollutants. Increasing readily available nitrogen content from about 50 mg N per 100 g compost to about 140 mg N per 100 g compost actually reduced micro-pollutant transformation, while changes in compost moisture content from 50% to 20% by weight, only had minor influence on micro-pollutant transformation. First-order micro-pollutant degradation rates for 13 organic micro-pollutants were calculated using data from both full- and bench-scale experiments. First-order degradation coefficients for both types of experiments were similar and ranged from 0.02 to 0.03 d(-1) on average, indicating that if a proper sampling strategy is employed, bench-scale experiments can be used to represent full-scale composting conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.
Room-temperature continuous-wave electrically injected InGaN-based laser directly grown on Si
NASA Astrophysics Data System (ADS)
Sun, Yi; Zhou, Kun; Sun, Qian; Liu, Jianping; Feng, Meixin; Li, Zengcheng; Zhou, Yu; Zhang, Liqun; Li, Deyao; Zhang, Shuming; Ikeda, Masao; Liu, Sheng; Yang, Hui
2016-09-01
Silicon photonics would greatly benefit from efficient, visible on-chip light sources that are electrically driven at room temperature. To fully utilize the benefits of large-scale, low-cost manufacturing foundries, it is highly desirable to grow direct bandgap III-V semiconductor lasers directly on Si. Here, we report the demonstration of a blue-violet (413 nm) InGaN-based laser diode grown directly on Si that operates under continuous-wave current injection at room temperature, with a threshold current density of 4.7 kA cm-2. The heteroepitaxial growth of GaN on Si is confronted with a large mismatch in both the lattice constant and the coefficient of thermal expansion, often resulting in a high density of defects and even microcrack networks. By inserting an Al-composition step-graded AlN/AlGaN multilayer buffer between the Si and GaN, we have not only successfully eliminated crack formation, but also effectively reduced the dislocation density. The result is the realization of a blue-violet InGaN-based laser on Si.
Self-transducing silicon nanowire electromechanical systems at room temperature.
He, Rongrui; Feng, X L; Roukes, M L; Yang, Peidong
2008-06-01
Electronic readout of the motions of genuinely nanoscale mechanical devices at room temperature imposes an important challenge for the integration and application of nanoelectromechanical systems (NEMS). Here, we report the first experiments on piezoresistively transduced very high frequency Si nanowire (SiNW) resonators with on-chip electronic actuation at room temperature. We have demonstrated that, for very thin (~90 nm down to ~30 nm) SiNWs, their time-varying strain can be exploited for self-transducing the devices' resonant motions at frequencies as high as approximately 100 MHz. The strain of wire elongation, which is only second-order in doubly clamped structures, enables efficient displacement transducer because of the enhanced piezoresistance effect in these SiNWs. This intrinsically integrated transducer is uniquely suited for a class of very thin wires and beams where metallization and multilayer complex patterning on devices become impractical. The 30 nm thin SiNW NEMS offer exceptional mass sensitivities in the subzeptogram range. This demonstration makes it promising to advance toward NEMS sensors based on ultrathin and even molecular-scale SiNWs, and their monolithic integration with microelectronics on the same chip.
NASA Astrophysics Data System (ADS)
Vignola, Joseph F.; Bucaro, Joseph A.; Tressler, James F.; Ellingston, Damon; Kurdila, Andrew J.; Adams, George; Marchetti, Barbara; Agnani, Alexia; Esposito, Enrico; Tomasini, Enrico P.
2004-06-01
A large-scale survey (~700 m2) of frescos and wall paintings was undertaken in the U.S. Capitol Building in Washington, D.C. to identify regions that may need structural repair due to detachment, delamination, or other defects. The survey encompassed eight pre-selected spaces including: Brumidi's first work at the Capitol building in the House Appropriations Committee room; the Parliamentarian's office; the House Speaker's office; the Senate Reception room; the President's Room; and three areas of the Brumidi Corridors. Roughly 60% of the area surveyed was domed or vaulted ceilings, the rest being walls. Approximately 250 scans were done ranging in size from 1 to 4 m2. The typical mesh density was 400 scan points per square meter. A common approach for post-processing time series called Proper Orthogonal Decomposition, or POD, was adapted to frequency-domain data in order to extract the essential features of the structure. We present a POD analysis for one of these panels, pinpointing regions that have experienced severe substructural degradation.
Does a surgical simulator improve resident operative performance of laparoscopic tubal ligation?
Banks, Erika H; Chudnoff, Scott; Karmin, Ira; Wang, Cuiling; Pardanani, Setul
2007-11-01
The purpose of this study was to assess whether a surgical skills simulator laboratory improves resident knowledge and operative performance of laparoscopic tubal ligation. Twenty postgraduate year 1 residents were assigned randomly to either a surgical simulator laboratory on laparoscopic tubal ligation together with apprenticeship teaching in the operating room or to apprenticeship teaching alone. Tests that were given before and after the training assessed basic knowledge. Attending physicians who were blinded to resident randomization status evaluated postgraduate year 1 performance on a laparoscopic tubal ligation in the operating room with 3 validated tools: a task-specific checklist, global rating scale, and pass/fail grade. Postgraduate year 1 residents who were assigned randomly to the surgical simulator laboratory performed significantly better than control subjects on all 3 surgical assessment tools (the checklist, the global score, and the pass/fail analysis) and scored significantly better on the knowledge posttest (all P < .0005). Compared with apprenticeship teaching alone, a surgical simulator laboratory on laparoscopic tubal ligation improved resident knowledge and performance in the operating room.
Acoustic Treatment Design Scaling Methods. Volume 3; Test Plans, Hardware, Results, and Evaluation
NASA Technical Reports Server (NTRS)
Yu, J.; Kwan, H. W.; Echternach, D. K.; Kraft, R. E.; Syed, A. A.
1999-01-01
The ability to design, build, and test miniaturized acoustic treatment panels on scale-model fan rigs representative of the full-scale engine provides not only a cost-savings, but an opportunity to optimize the treatment by allowing tests of different designs. To be able to use scale model treatment as a full-scale design tool, it is necessary that the designer be able to reliably translate the scale model design and performance to an equivalent full-scale design. The primary objective of the study presented in this volume of the final report was to conduct laboratory tests to evaluate liner acoustic properties and validate advanced treatment impedance models. These laboratory tests include DC flow resistance measurements, normal incidence impedance measurements, DC flow and impedance measurements in the presence of grazing flow, and in-duct liner attenuation as well as modal measurements. Test panels were fabricated at three different scale factors (i.e., full-scale, half-scale, and one-fifth scale) to support laboratory acoustic testing. The panel configurations include single-degree-of-freedom (SDOF) perforated sandwich panels, SDOF linear (wire mesh) liners, and double-degree-of-freedom (DDOF) linear acoustic panels.
NASA Technical Reports Server (NTRS)
Penrose, C. J.
1987-01-01
The difficulties of modeling the complex recirculating flow fields produced by multiple jet STOVL aircraft close to the ground have led to extensive use of experimental model tests to predict intake Hot Gas Reingestion (HGR). Model test results reliability is dependent on a satisfactory set of scaling rules which must be validated by fully comparable full scale tests. Scaling rules devised in the U.K. in the mid 60's gave good model/full scale agreement for the BAe P1127 aircraft. Until recently no opportunity has occurred to check the applicability of the rules to the high energy exhaust of current ASTOVL aircraft projects. Such an opportunity has arisen following tests on a Tethered Harrier. Comparison of this full scale data and results from tests on a model configuration approximating to the full scale aircraft geometry has shown discrepancies between HGR levels. These discrepancies although probably due to geometry and other model/scale differences indicate some reexamination of the scaling rules is needed. Therefore the scaling rules are reviewed, further scaling studies planned are described and potential areas for further work are suggested.
Devcich, Daniel A; Weller, Jennifer; Mitchell, Simon J; McLaughlin, Scott; Barker, Lauren; Rudolph, Jenny W; Raemer, Daniel B; Zammert, Martin; Singer, Sara J; Torrie, Jane; Frampton, Chris Ma; Merry, Alan F
2016-10-01
Realising the full potential of the WHO Surgical Safety Checklist (SSC) to reduce perioperative harm requires the constructive engagement of all operating room (OR) team members during its administration. To facilitate research on SSC implementation, a valid and reliable instrument is needed for measuring OR team behaviours during its administration. We developed a behaviourally anchored rating scale (BARS) for this purpose. We used a modified Delphi process, involving 16 subject matter experts, to compile a BARS with behavioural domains applicable to all three phases of the SSC. We evaluated the instrument in 80 adult OR cases and 30 simulated cases using two medical student raters and seven expert raters, respectively. Intraclass correlation coefficients were calculated to assess inter-rater reliability. Internal consistency and instrument discrimination were explored. Sample size estimates for potential study designs using the instrument were calculated. The Delphi process resulted in a BARS instrument (the WHOBARS) with five behavioural domains. Intraclass correlation coefficients calculated from the OR cases exceeded 0.80 for 80% of the instrument's domains across the SSC phases. The WHOBARS showed high internal consistency across the three phases of the SSC and ability to discriminate among surgical cases in both clinical and simulated settings. Fewer than 20 cases per group would be required to show a difference of 1 point between groups in studies of the SSC, where α=0.05 and β=0.8. We have developed a generic instrument for comprehensively rating the administration of the SSC and informing initiatives to realise its full potential. We have provided data supporting its capacity for discrimination, internal consistency and inter-rater reliability. Further psychometric evaluation is warranted. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
NASA Technical Reports Server (NTRS)
Cezairliyan, Ared
1993-01-01
Rapid (subsecond) heating techniques developed at the National Institute of Standards and Technology for the measurements of selected thermophysical and related properties of metals and alloys at high temperatures (above 1000 C) are described. The techniques are based on rapid resistive self-heating of the specimen from room temperature to the desired high temperature in short times and measuring the relevant experimental quantities, such as electrical current through the specimen, voltage across the specimen, specimen temperature, length, etc., with appropriate time resolution. The first technique, referred to as the millisecond-resolution technique, is for measurements on solid metals and alloys in the temperature range 1000 C to the melting temperature of the specimen. It utilizes a heavy battery bank for the energy source, and the total heating time of the specimen is typically in the range of 100-1000 ms. Data are recorded digitally every 0.5 ms with a full-scale resolution of about one part in 8000. The properties that can be measured with this system are as follows: specific heat, enthalpy, thermal expansion, electrical resistivity, normal spectral emissivity, hemispherical total emissivity, temperature and energy of solid-solid phase transformations, and melting temperature (solidus). The second technique, referred to as the microsecond-resolution technique, is for measurements on liquid metals and alloys in the temperature range 1200 to 6000 C. It utilizes a capacitor bank for the energy source, and the total heating time of the specimen is typically in the range 50-500 micro-s. Data are recorded digitally every 0.5 micro-s with a full-scale resolution of about one part in 4000. The properties that can be measured with this system are: melting temperature (solidus and liquidus), heat of fusion, specific heat, enthalpy, and electrical resistivity. The third technique is for measurements of the surface tension of liquid metals and alloys at their melting temperature. It utilizes a modified millisecond-resolution heating system designed for use in a microgravity environment.
Ngai, K L; Habasaki, J; Prevosto, D; Capaccioli, S; Paluch, Marian
2012-07-21
By now it is well established that the structural α-relaxation time, τ(α), of non-associated small molecular and polymeric glass-formers obey thermodynamic scaling. In other words, τ(α) is a function Φ of the product variable, ρ(γ)/T, where ρ is the density and T the temperature. The constant γ as well as the function, τ(α) = Φ(ρ(γ)/T), is material dependent. Actually this dependence of τ(α) on ρ(γ)/T originates from the dependence on the same product variable of the Johari-Goldstein β-relaxation time, τ(β), or the primitive relaxation time, τ(0), of the coupling model. To support this assertion, we give evidences from various sources itemized as follows. (1) The invariance of the relation between τ(α) and τ(β) or τ(0) to widely different combinations of pressure and temperature. (2) Experimental dielectric and viscosity data of glass-forming van der Waals liquids and polymer. (3) Molecular dynamics simulations of binary Lennard-Jones (LJ) models, the Lewis-Wahnström model of ortho-terphenyl, 1,4 polybutadiene, a room temperature ionic liquid, 1-ethyl-3-methylimidazolium nitrate, and a molten salt 2Ca(NO(3))(2)·3KNO(3) (CKN). (4) Both diffusivity and structural relaxation time, as well as the breakdown of Stokes-Einstein relation in CKN obey thermodynamic scaling by ρ(γ)/T with the same γ. (5) In polymers, the chain normal mode relaxation time, τ(N), is another function of ρ(γ)/T with the same γ as segmental relaxation time τ(α). (6) While the data of τ(α) from simulations for the full LJ binary mixture obey very well the thermodynamic scaling, it is strongly violated when the LJ interaction potential is truncated beyond typical inter-particle distance, although in both cases the repulsive pair potentials coincide for some distances.
Jang, Sung Ho; Hyun, Yi Ji; Lee, Han Do
2016-06-01
We report on a patient who survived cardiac arrest and showed recovery of consciousness and an injured ARAS at the early stage of hypoxic-ischemic brain injury (HI- BI) for 3 weeks, which was demonstrated by diffusion tensor tractography (DTT).A 52-year-old male patient who had suffered cardiac arrest caused by acute coronary syndrome was resuscitated immediately by a layman and paramedics for ∼25 minutes. He was then transferred immediately to the emergency room of a local medical center. When starting rehabilitation at 2 weeks after onset, his consciousness was impaired, with a Glasgow Coma Scale (GCS) score of 8 and Coma Recovery Scale-Revised (GRS-R) score of 8. He underwent comprehensive rehabilitative therapy, including drugs for recovery of consciousness. He recovered well and rapidly so that his consciousness had recovered to full scores in terms of GCS:15 and GRS-R:23 at 5 weeks after onset.The left lower dorsal and right lower ventral ARAS had become thicker on 5-week DTT compared with 2-week DTT (Fig. 1B). Regarding the change of neural connectivity of the thalamic ILN, increased neural connectivity to the basal forebrain and prefrontal cortex was observed in both hemispheres on 5-week DTT compared with 2-week DTT.Recovery of an injured ARAS was demonstrated in a patient who survived cardiac arrest and his consciousness showed rapid and good recovery for 3 weeks at the early stage of HI-BI.
Perceptions of perioperative nursing competence: a cross-country comparison.
Gillespie, Brigid M; Harbeck, Emma B; Falk-Brynhildsen, Karin; Nilsson, Ulrica; Jaensson, Maria
2018-01-01
Throughout many countries, professional bodies rely on yearly self-assessment of competence for ongoing registration; therefore, nursing competence is pivotal to safe clinical practice. Our aim was to describe and compare perioperative nurses' perceptions of competence in four countries, while examining the effect of specialist education and years of experience in the operating room. We conducted a secondary analysis of cross-sectional surveys from four countries including; Australia, Canada, Scotland, and Sweden. The 40-item Perceived Perioperative Competence Scale-Revised (PPCS-R), was used with a total sample of 768 respondents. We used a factorial design to examine the influence of country, years of experience in the operating room and specialist education on nurses' reported perceived perioperative competence. Regardless of country origin, nurses with specialist qualifications reported higher perceived perioperative competence when compared to nurses without specialist education. However, cross-country differences were dependent on nurses' number of years of experience in the operating room. Nurses from Sweden with 6-10 years of experience in the operating room reported lower perceived perioperative competence when compared to Australian nurses. In comparing nurses with > 10 years of experience, Swedish nurses reported significantly lower perceived perioperative competence when compared to nurses from Australia, Canada and Scotland. Researchers need to consider educational level and years of experience in the perioperative context when examining constructs such as competence.
Using sieving and pretreatment to separate plastics during end-of-life vehicle recycling.
Stagner, Jacqueline A; Sagan, Barsha; Tam, Edwin Kl
2013-09-01
Plastics continue to be a challenge for recovering materials at the end-of-life for vehicles. However, it may be possible to improve the recovery of plastics by exploiting material characteristics, such as shape, or by altering their behavior, such as through temperature changes, in relation to recovery processes and handling. Samples of a 2009 Dodge Challenger front fascia were shredded in a laboratory-scale hammer mill shredder. A 2 × 2 factorial design study was performed to determine the effect of sample shape (flat versus curved) and sample temperature (room temperature versus cryogenic temperature) on the size of the particles exiting from the shredder. It was determined that sample shape does not affect the particle size; however, sample temperature does affect the particle size. At cryogenic temperatures, the distribution of particle sizes is much narrower than at room temperature. Having a more uniform particle size could make recovery of plastic particles, such as these more efficient during the recycling of end-of-life vehicles. Samples of Chrysler minivan headlights were also shredded at room temperature and at cryogenic temperatures. The size of the particles of the two different plastics in the headlights is statistically different both at room temperature and at cryogenic temperature, and the particles are distributed narrowly. The research suggests that incremental changes in end-of-life vehicle processing could be effective in aiding materials recovery.
Maillot, Pauline; Dommes, Aurélie; Dang, Nguyen-Thong; Vienne, Fabrice
2017-02-01
A virtual-reality training program has been developed to help older pedestrians make safer street-crossing decisions in two-way traffic situations. The aim was to develop a small-scale affordable and transportable simulation device that allowed transferring effects to a full-scale device involving actual walking. 20 younger adults and 40 older participants first participated in a pre-test phase to assess their street crossings using both full-scale and small-scale simulation devices. Then, a trained older group (20 participants) completed two 1.5-h training sessions with the small-scale device, whereas an older control group received no training (19 participants). Thereafter, the 39 older trained and untrained participants took part in a 1.5-h post-test phase again with both devices. Pre-test phase results suggested significant differences between both devices in the group of older participants only. Unlike younger participants, older participants accepted more often to cross and had more collisions on the small-scale simulation device than on the full-scale one. Post-test phase results showed that training older participants on the small-scale device allowed a significant global decrease in the percentage of accepted crossings and collisions on both simulation devices. But specific improvements regarding the way participants took into account the speed of approaching cars and vehicles in the far lane were notable only on the full-scale simulation device. The findings suggest that the small-scale simulation device triggers a greater number of unsafe decisions compared to a full-scale one that allows actual crossings. But findings reveal that such a small-scale simulation device could be a good means to improve the safety of street-crossing decisions and behaviors among older pedestrians, suggesting a transfer of learning effect between the two simulation devices, from training people with a miniature device to measuring their specific progress with a full-scale one. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kalkan, Fatih; Zaum, Christopher; Morgenstern, Karina
2012-10-01
A beetle type stage and a flexure scanning stage are combined to form a two stages scanning tunneling microscope (STM). It operates at room temperature in ultrahigh vacuum and is capable of scanning areas up to 300 μm × 450 μm down to resolution on the nanometer scale. This multi-scale STM has been designed and constructed in order to investigate prestructured metallic or semiconducting micro- and nano-structures in real space from atomic-sized structures up to the large-scale environment. The principle of the instrument is demonstrated on two different systems. Gallium nitride based micropillars demonstrate scan areas up to hundreds of micrometers; a Au(111) surface demonstrates nanometer resolution.
Wavelength-scale photonic-crystal laser formed by electron-beam-induced nano-block deposition.
Seo, Min-Kyo; Kang, Ju-Hyung; Kim, Myung-Ki; Ahn, Byeong-Hyeon; Kim, Ju-Young; Jeong, Kwang-Yong; Park, Hong-Gyu; Lee, Yong-Hee
2009-04-13
A wavelength-scale cavity is generated by printing a carbonaceous nano-block on a photonic-crystal waveguide. The nanometer-size carbonaceous block is grown at a pre-determined region by the electron-beam-induced deposition method. The wavelength-scale photonic-crystal cavity operates as a single mode laser, near 1550 nm with threshold of approximately 100 microW at room temperature. Finite-difference time-domain computations show that a high-quality-factor cavity mode is defined around the nano-block with resonant wavelength slightly longer than the dispersion-edge of the photonic-crystal waveguide. Measured near-field images exhibit photon distribution well-localized in the proximity of the printed nano-block. Linearly-polarized emission along the vertical direction is also observed.
Wijdicks, Eelco F M; Kramer, Andrew A; Rohs, Thomas; Hanna, Susan; Sadaka, Farid; O'Brien, Jacklyn; Bible, Shonna; Dickess, Stacy M; Foss, Michelle
2015-02-01
Impaired consciousness has been incorporated in prediction models that are used in the ICU. The Glasgow Coma Scale has value but is incomplete and cannot be assessed in intubated patients accurately. The Full Outline of UnResponsiveness score may be a better predictor of mortality in critically ill patients. Thirteen ICUs at five U.S. hospitals. One thousand six hundred ninety-five consecutive unselected ICU admissions during a six-month period in 2012. Glasgow Coma Scale and Full Outline of UnResponsiveness score were recorded within 1 hour of admission. Baseline characteristics and physiologic components of the Acute Physiology and Chronic Health Evaluation system, as well as mortality were linked to Glasgow Coma Scale/Full Outline of UnResponsiveness score information. None. We recruited 1,695 critically ill patients, of which 1,645 with complete data could be linked to data in the Acute Physiology and Chronic Health Evaluation system. The area under the receiver operating characteristic curve of predicting ICU mortality using the Glasgow Coma Scale was 0.715 (95% CI, 0.663-0.768) and using the Full Outline of UnResponsiveness score was 0.742 (95% CI, 0.694-0.790), statistically different (p = 0.001). A similar but nonsignificant difference was found for predicting hospital mortality (p = 0.078). The respiratory and brainstem reflex components of the Full Outline of UnResponsiveness score showed a much wider range of mortality than the verbal component of Glasgow Coma Scale. In multivariable models, the Full Outline of UnResponsiveness score was more useful than the Glasgow Coma Scale for predicting mortality. The Full Outline of UnResponsiveness score might be a better prognostic tool of ICU mortality than the Glasgow Coma Scale in critically ill patients, most likely a result of incorporating brainstem reflexes and respiration into the Full Outline of UnResponsiveness score.
Model helicopter rotor high-speed impulsive noise: Measured acoustics and blade pressures
NASA Technical Reports Server (NTRS)
Boxwell, D. A.; Schmitz, F. H.; Splettstoesser, W. R.; Schultz, K. J.
1983-01-01
A 1/17-scale research model of the AH-1 series helicopter main rotor was tested. Model-rotor acoustic and simultaneous blade pressure data were recorded at high speeds where full-scale helicopter high-speed impulsive noise levels are known to be dominant. Model-rotor measurements of the peak acoustic pressure levels, waveform shapes, and directively patterns are directly compared with full-scale investigations, using an equivalent in-flight technique. Model acoustic data are shown to scale remarkably well in shape and in amplitude with full-scale results. Model rotor-blade pressures are presented for rotor operating conditions both with and without shock-like discontinuities in the radiated acoustic waveform. Acoustically, both model and full-scale measurements support current evidence that above certain high subsonic advancing-tip Mach numbers, local shock waves that exist on the rotor blades ""delocalize'' and radiate to the acoustic far-field.
NASA Technical Reports Server (NTRS)
Stubbs, Sandy M.
1967-01-01
An experimental investigation was made to determine impact water pressures, accelerations, and landing dynamics of a 1/4-scale dynamic model of the command module of the Apollo spacecraft. A scaled-stiffness aft heat shield was used on the model to simulate the structural deflections of the full-scale heat shield. Tests were made on water to obtain impact pressure data at a simulated parachute letdown (vertical) velocity component of approximately 30 ft/sec (9.1 m/sec) full scale. Additional tests were made on water, sand, and hard clay-gravel landing surfaces at simulated vertical velocity components of 23 ft/sec (7.0 m/sec) full scale. Horizontal velocity components investigated ranged from 0 to 50 ft/sec (15 m/sec) full scale and the pitch attitudes ranged from -40 degrees to 29 degrees. Roll attitudes were O degrees, 90 degrees, and 180 degrees, and the yaw attitude was 0 degrees.
Mewes, André; Hensen, Bennet; Wacker, Frank; Hansen, Christian
2017-02-01
In this article, we systematically examine the current state of research of systems that focus on touchless human-computer interaction in operating rooms and interventional radiology suites. We further discuss the drawbacks of current solutions and underline promising technologies for future development. A systematic literature search of scientific papers that deal with touchless control of medical software in the immediate environment of the operation room and interventional radiology suite was performed. This includes methods for touchless gesture interaction, voice control and eye tracking. Fifty-five research papers were identified and analyzed in detail including 33 journal publications. Most of the identified literature (62 %) deals with the control of medical image viewers. The others present interaction techniques for laparoscopic assistance (13 %), telerobotic assistance and operating room control (9 % each) as well as for robotic operating room assistance and intraoperative registration (3.5 % each). Only 8 systems (14.5 %) were tested in a real clinical environment, and 7 (12.7 %) were not evaluated at all. In the last 10 years, many advancements have led to robust touchless interaction approaches. However, only a few have been systematically evaluated in real operating room settings. Further research is required to cope with current limitations of touchless software interfaces in clinical environments. The main challenges for future research are the improvement and evaluation of usability and intuitiveness of touchless human-computer interaction and the full integration into productive systems as well as the reduction of necessary interaction steps and further development of hands-free interaction.
Size-Dependent Brittle-to-Ductile Transition in Silica Glass Nanofibers.
Luo, Junhang; Wang, Jiangwei; Bitzek, Erik; Huang, Jian Yu; Zheng, He; Tong, Limin; Yang, Qing; Li, Ju; Mao, Scott X
2016-01-13
Silica (SiO2) glass, an essential material in human civilization, possesses excellent formability near its glass-transition temperature (Tg > 1100 °C). However, bulk SiO2 glass is very brittle at room temperature. Here we show a surprising brittle-to-ductile transition of SiO2 glass nanofibers at room temperature as its diameter reduces below 18 nm, accompanied by ultrahigh fracture strength. Large tensile plastic elongation up to 18% can be achieved at low strain rate. The unexpected ductility is due to a free surface affected zone in the nanofibers, with enhanced ionic mobility compared to the bulk that improves ductility by producing more bond-switching events per irreversible bond loss under tensile stress. Our discovery is fundamentally important for understanding the damage tolerance of small-scale amorphous structures.
Cost-effective fabrication of thermal- and chemical-stable ZIF-9 nanocrystals at ammonia atmosphere
NASA Astrophysics Data System (ADS)
Ebrahimi, Arash; Mansournia, Mohammadreza
2017-12-01
In this study, room temperature synthesis of zeolitic imidazolate framework-9 (ZIF-9) nanocrystals is reported for the first time at ammonia atmosphere in the absence of any organic additive. High thermal stability of the as-fabricated ZIF-9 up to 300 °C is illustrated by TG and XRD data. Also, the chemical resistance of product to harsh and severe solvothermal conditions introduces it to be an objective as potential material in many applications. Besides, the modest microporosity of the as-obtained ZIF-9 materials attracts more attentions for further investigation compared to those fabricated in organic solvents. By and large, the represented low-cost and room temperature synthetic method can be applicable in the large scale preparation of ZIF-9 for potentially practical utilization.
Ma, Xuedan; Roslyak, Oleskiy; Duque, Juan G; Pang, Xiaoying; Doorn, Stephen K; Piryatinski, Andrei; Dunlap, David H; Htoon, Han
2015-07-03
Pump-dependent photoluminescence imaging and second-order photon correlation studies have been performed on individual single-walled carbon nanotubes (SWCNTs) at room temperature. These studies enable the extraction of both the exciton diffusion constant and the Auger recombination coefficient. A linear correlation between these parameters is attributed to the effect of environmental disorder in setting the exciton mean free path and capture-limited Auger recombination at this length scale. A suppression of photon antibunching is attributed to the creation of multiple spatially nonoverlapping excitons in SWCNTs, whose diffusion length is shorter than the laser spot size. We conclude that complete antibunching at room temperature requires an enhancement of the exciton-exciton annihilation rate that may become realizable in SWCNTs allowing for strong exciton localization.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-09
... scale of the businesses, organizations, and governmental jurisdictions subject to regulation. To achieve... Number FAA-2010- 0218 using any of the following methods: Federal eRulemaking Portal: Go to http://www... comments to Docket Operations in Room W12-140 of the West Building Ground Floor at 1200 New Jersey Avenue...
Microbial desulfurization of coal
NASA Technical Reports Server (NTRS)
Dastoor, M. N.; Kalvinskas, J. J.
1978-01-01
Experiments indicate that several sulfur-oxidizing bacteria strains have been very efficient in desulfurizing coal. Process occurs at room temperature and does not require large capital investments of high energy inputs. Process may expand use of abundant reserves of high-sulfur bituminous coal, which is currently restricted due to environmental pollution. On practical scale, process may be integrated with modern coal-slurry transportation lines.
No Sense of the Struggle: Creating a Context for Survivance at the NMAI
ERIC Educational Resources Information Center
Atalay, Sonya
2006-01-01
The National Museum of the American Indian (NMAI) attempts to profoundly change the practice of museology and the role of Indigenous people in museums on a grand scale. In some ways it is successful in its mission, yet other areas leave room for improvement. This article focuses on the improvements that NMAI should adopt. The author also offers…
Design, Fabrication, Characterization and Modeling of Integrated Functional Materials
2013-10-01
coated microwire to change the temperature of an FBG. We show below that the proposed sensor probe, with a relatively poor thermal coupling with FBG...Seebeck coefficient and decreased thermal conductivity due to the phenomenological properties of nanometer length scales, including enhanced...nanocomposites as compared to bulk polycrystalline materials, in addition to similar thermal conductivities , results in enhanced room temperature ZT as
Mori, Mihoko; Hoshiko, Michiko; Hara, Kunio; Ishitake, Tatsuya; Saga, Tsuyoshi; Yamaki, Koichi
2012-01-01
To examine the effect of large-scale repair work on indoor formaldehyde (FA) levels and subjective symptoms in medical students during a gross anatomy dissection course. We measured the indoor FA levels, room air temperature, and room humidity during a gross anatomy dissection course. In addition, the prevalence of subjective symptoms, keeping allergy state, and wearing personal protective equipment were surveyed in two groups of students using a self-administered questionnaire. The mean indoor FA levels before and after repair work were 1.22 ppm and 0.14 ppm, respectively. The mean indoor FA level significantly decreased after repair work. The prevalences of most subjective symptoms before the anatomy practice were similar before and after the repair work. However, the prevalences of most subjective symptoms during the anatomy practice were lower after the repair work. The mean indoor FA levels and prevalences of subjective symptoms decreased after the repair work. We have to continuously monitor indoor FA levels, carry out private countermeasures to minimize exposure to FA, and maintain equipment for ventilation to be able to conduct practice in a comfortable environment.
Airfoil Ice-Accretion Aerodynamics Simulation
NASA Technical Reports Server (NTRS)
Bragg, Michael B.; Broeren, Andy P.; Addy, Harold E.; Potapczuk, Mark G.; Guffond, Didier; Montreuil, E.
2007-01-01
NASA Glenn Research Center, ONERA, and the University of Illinois are conducting a major research program whose goal is to improve our understanding of the aerodynamic scaling of ice accretions on airfoils. The program when it is completed will result in validated scaled simulation methods that produce the essential aerodynamic features of the full-scale iced-airfoil. This research will provide some of the first, high-fidelity, full-scale, iced-airfoil aerodynamic data. An initial study classified ice accretions based on their aerodynamics into four types: roughness, streamwise ice, horn ice, and spanwise-ridge ice. Subscale testing using a NACA 23012 airfoil was performed in the NASA IRT and University of Illinois wind tunnel to better understand the aerodynamics of these ice types and to test various levels of ice simulation fidelity. These studies are briefly reviewed here and have been presented in more detail in other papers. Based on these results, full-scale testing at the ONERA F1 tunnel using cast ice shapes obtained from molds taken in the IRT will provide full-scale iced airfoil data from full-scale ice accretions. Using these data as a baseline, the final step is to validate the simulation methods in scale in the Illinois wind tunnel. Computational ice accretion methods including LEWICE and ONICE have been used to guide the experiments and are briefly described and results shown. When full-scale and simulation aerodynamic results are available, these data will be used to further develop computational tools. Thus the purpose of the paper is to present an overview of the program and key results to date.
Haig, Sarah-Jane; Quince, Christopher; Davies, Robert L; Dorea, Caetano C; Collins, Gavin
2014-09-15
Previous laboratory-scale studies to characterise the functional microbial ecology of slow sand filters have suffered from methodological limitations that could compromise their relevance to full-scale systems. Therefore, to ascertain if laboratory-scale slow sand filters (L-SSFs) can replicate the microbial community and water quality production of industrially operated full-scale slow sand filters (I-SSFs), eight cylindrical L-SSFs were constructed and were used to treat water from the same source as the I-SSFs. Half of the L-SSFs sand beds were composed of sterilized sand (sterile) from the industrial filters and the other half with sand taken directly from the same industrial filter (non-sterile). All filters were operated for 10 weeks, with the microbial community and water quality parameters sampled and analysed weekly. To characterize the microbial community phyla-specific qPCR assays and 454 pyrosequencing of the 16S rRNA gene were used in conjunction with an array of statistical techniques. The results demonstrate that it is possible to mimic both the water quality production and the structure of the microbial community of full-scale filters in the laboratory - at all levels of taxonomic classification except OTU - thus allowing comparison of LSSF experiments with full-scale units. Further, it was found that the sand type composing the filter bed (non-sterile or sterile), the water quality produced, the age of the filters and the depth of sand samples were all significant factors in explaining observed differences in the structure of the microbial consortia. This study is the first to the authors' knowledge that demonstrates that scaled-down slow sand filters can accurately reproduce the water quality and microbial consortia of full-scale slow sand filters. Copyright © 2014 Elsevier Ltd. All rights reserved.
Singer, Brett C; Hodgson, Alfred T; Guevarra, Karla S; Hawley, Elisabeth L; Nazaroff, William W
2002-03-01
We measured the emissions of 26 gas-phase organic compounds in environmental tobacco smoke (ETS) using a model room that simulates realistic conditions in residences and offices. Exposure-relevant emission factors (EREFs), which include the effects of sorption and re-emission over a 24-h period, were calculated by mass balance from measured compound concentrations and chamber ventilation rates in a 50-m3 room constructed and furnished with typical materials. Experiments were conducted at three smoking rates (5, 10, and 20 cigarettes day(-1)), three ventilation rates (0.3, 0.6, and 2 h(-1)), and three furnishing levels (wallboard with aluminum flooring, wallboard with carpet, and full furnishings). Smoking rate did not affect EREFs, suggesting that sorption was linearly related to gas-phase concentration. Furnishing level and ventilation rate in the model room had little effect on EREFs of several ETS compounds including 1,3-butadiene, acrolein, acrylonitrile, benzene, toluene, and styrene. However, sorptive losses at low ventilation with full furnishings reduced EREFs for the ETS tracers nicotine and 3-ethenylpyridine by as much as 90 and 65% as compared to high ventilation, wallboard/aluminum experiments. Likewise, sorptive losses were 40-70% for phenol, cresols, naphthalene, and methylnaphthalenes. Sorption persisted for many compounds; for example, almost all of the sorbed nicotine and most of the sorbed cresol remained sorbed 3 days after smoking. EREFs can be used in models and with ETS tracer-based methods to refine and improve estimates of exposures to ETS constituents.
Characterization of the Boundary Layers on Full-Scale Bluefin Tuna
2014-09-30
NUWC-NPT Technical Report 12,163 30 September 2014 Characterization of the Boundary Layers on Full-Scale Bluefin Tuna Kimberly M. Cipolla...Center Division Newport, under Section 219 Research Project, “Characterization of the Boundary Layers on Full-Scale Bluefin Tuna ,” principal...K. Amaral (Code 1522). The author thanks Barbara Block (Stanford University), head of the Tuna Research and Conservation Center (TRCC) at the
Full-Scale Accelerated Testing of Multi-axial Geogrid Stabilized Flexible Pavements
2017-06-01
costs and reduced budgets, transportation officials are often tasked with applying innovative solutions to pavement design and construction projects... pavement designers . 1.2 Objective The objective of this effort was to construct and traffic full-scale flexible pavement sections to provide...Development Center (ERDC) constructed the full-scale test section as designed by Tensar under shelter in its Hangar 2 Pavement Test Facility. During
Nonlinear Analysis and Scaling Laws for Noncircular Composite Structures Subjected to Combined Loads
NASA Technical Reports Server (NTRS)
Hilburger, Mark W.; Rose, Cheryl A.; Starnes, James H., Jr.
2001-01-01
Results from an analytical study of the response of a built-up, multi-cell noncircular composite structure subjected to combined internal pressure and mechanical loads are presented. Nondimensional parameters and scaling laws based on a first-order shear-deformation plate theory are derived for this noncircular composite structure. The scaling laws are used to design sub-scale structural models for predicting the structural response of a full-scale structure representative of a portion of a blended-wing-body transport aircraft. Because of the complexity of the full-scale structure, some of the similitude conditions are relaxed for the sub-scale structural models. Results from a systematic parametric study are used to determine the effects of relaxing selected similitude conditions on the sensitivity of the effectiveness of using the sub-scale structural model response characteristics for predicting the full-scale structure response characteristics.
Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements
NASA Technical Reports Server (NTRS)
Vargas, Magda B.; Counter, Douglas
2011-01-01
Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-21
... stated that an extension would require them to continue to pay full price for a hotel room during the... accommodations, there were some comments from title II entities. Organizations representing the hotel industry and individual owners and operators of hotels and campgrounds provided the largest number of comments...
Fossil Ridge School Intermediate: Restructure the Culture--Transform the School
ERIC Educational Resources Information Center
Principal Leadership, 2013
2013-01-01
Ask a room full of sixth and seventh graders at Fossil Ridge Intermediate School in St. George, UT, to name their favorite part of the day and the answer is, in unison, always the same: REAL (respect, explore, achieve, lead) Time. This 35-minute block embedded into the school's schedule three days each week provides immediate, specific…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... include a main gaming hall, food and beverage services, retail space, banquet/meeting space, and administration space. Food and beverage facilities would include three full service restaurants, a five-tenant food court, a buffet, four bars and a lounge. The hotel would include 200 rooms, a resort style pool...
Energy-filtered cold electron transport at room temperature
Bhadrachalam, Pradeep; Subramanian, Ramkumar; Ray, Vishva; Ma, Liang-Chieh; Wang, Weichao; Kim, Jiyoung; Cho, Kyeongjae; Koh, Seong Jin
2014-01-01
Fermi-Dirac electron thermal excitation is an intrinsic phenomenon that limits functionality of various electron systems. Efforts to manipulate electron thermal excitation have been successful when the entire system is cooled to cryogenic temperatures, typically <1 K. Here we show that electron thermal excitation can be effectively suppressed at room temperature, and energy-suppressed electrons, whose energy distribution corresponds to an effective electron temperature of ~45 K, can be transported throughout device components without external cooling. This is accomplished using a discrete level of a quantum well, which filters out thermally excited electrons and permits only energy-suppressed electrons to participate in electron transport. The quantum well (~2 nm of Cr2O3) is formed between source (Cr) and tunnelling barrier (SiO2) in a double-barrier-tunnelling-junction structure having a quantum dot as the central island. Cold electron transport is detected from extremely narrow differential conductance peaks in electron tunnelling through CdSe quantum dots, with full widths at half maximum of only ~15 mV at room temperature. PMID:25204839
NASA Astrophysics Data System (ADS)
Wang, Meng; Jiang, Chunlei; Zhang, Songquan; Song, Xiaohe; Tang, Yongbing; Cheng, Hui-Ming
2018-06-01
Calcium-ion batteries (CIBs) are attractive candidates for energy storage because Ca2+ has low polarization and a reduction potential (-2.87 V versus standard hydrogen electrode, SHE) close to that of Li+ (-3.04 V versus SHE), promising a wide voltage window for a full battery. However, their development is limited by difficulties such as the lack of proper cathode/anode materials for reversible Ca2+ intercalation/de-intercalation, low working voltages (<2 V), low cycling stability, and especially poor room-temperature performance. Here, we report a CIB that can work stably at room temperature in a new cell configuration using graphite as the cathode and tin foils as the anode as well as the current collector. This CIB operates on a highly reversible electrochemical reaction that combines hexafluorophosphate intercalation/de-intercalation at the cathode and a Ca-involved alloying/de-alloying reaction at the anode. An optimized CIB exhibits a working voltage of up to 4.45 V with capacity retention of 95% after 350 cycles.
Wasicek, Philip; Kaswan, Sumesh; Messing, Susan; Gusenoff, Jeffrey A
2013-11-01
Medical photography of body contouring patients often requires complete nudity, placing patients in a vulnerable situation. We investigated patient perspectives on full body photography in an effort to better protect the patients and enhance comfort with the photography process. Sixty-five massive weight loss patients were identified who underwent body contouring surgery with full body photography. Photographs were taken at the time of initial consult, time of marking, and postoperatively. A retrospective chart review was performed to assess body mass indices and comorbidities, and a telephone survey inquired about several aspects of the photographic process. Fifty-six (86%) patients participated. Patients were more comfortable at the time of markings (P = 0.0004) and at the postoperative session (P = 0.0009). Patients' perception of positive body image increased after body contouring surgery (P < 0.0001). Patients who reported being comfortable at their initial session had a higher body mass index (P = 0.0027). Professionalism of the staff was rated as the most important aspect of the photographic process. Patients preferring a chaperone of the same sex tended to be less comfortable with the process (P = 0.015). Most patients preferred the surgeon as the photographer (P = 0.03). Patient comfort with full body photography improves quickly as they move through the surgical process. Maintaining professionalism is the most important factor in achieving patient trust and comfort. Limiting the number of observers in the room, providing explicit details of the photography process, and having at least 1 person of the same sex in the room can optimize patient safety and comfort.
Cyanobacteria, Toxins and Indicators: Full-Scale Monitoring & Bench-Scale Treatment Studies
Summary of: 1) Lake Erie 2014 bloom season full-scale treatment plant monitoring data for cyanobacteria and cyanobacteria toxins; 2) Follow-up work to examine the impact of pre-oxidation on suspensions of intact toxin-producing cyanobacterial cells.
NASA Astrophysics Data System (ADS)
Grujicic, M.; Galgalikar, R.; Snipes, J. S.; Ramaswami, S.
2016-01-01
In our recent work, a multi-length-scale room-temperature material model for SiC/SiC ceramic-matrix composites (CMCs) was derived and parameterized. The model was subsequently linked with a finite-element solver so that it could be used in a general room-temperature, structural/damage analysis of gas-turbine engine CMC components. Due to its multi-length-scale character, the material model enabled inclusion of the effects of fiber/tow (e.g., the volume fraction, size, and properties of the fibers; fiber-coating material/thickness; decohesion properties of the coating/matrix interfaces; etc.) and ply/lamina (e.g., the 0°/90° cross-ply versus plain-weave architectures, the extent of tow crimping in the case of the plain-weave plies, cohesive properties of the inter-ply boundaries, etc.) length-scale microstructural/architectural parameters on the mechanical response of the CMCs. One of the major limitations of the model is that it applies to the CMCs in their as-fabricated conditions (i.e., the effect of prolonged in-service environmental exposure and the associated material aging-degradation is not accounted for). In the present work, the model is upgraded to include such in-service environmental-exposure effects. To demonstrate the utility of the upgraded material model, it is used within a finite-element structural/failure analysis involving impact of a toboggan-shaped turbine shroud segment by a foreign object. The results obtained clearly revealed the effects that different aspects of the in-service environmental exposure have on the material degradation and the extent of damage suffered by the impacted CMC toboggan-shaped shroud segment.
van der Veer, Sabine N; Jager, Kitty J; Visserman, Ella; Beekman, Robert J; Boeschoten, Els W; de Keizer, Nicolette F; Heuveling, Lara; Stronks, Karien; Arah, Onyebuchi A
2012-08-01
Patient experience is an established indicator of quality of care. Validated tools that measure both experiences and priorities are lacking for chronic dialysis care, hampering identification of negative experiences that patients actually rate important. We developed two Consumer Quality (CQ) index questionnaires, one for in-centre haemodialysis (CHD) and the other for peritoneal dialysis and home haemodialysis (PHHD) care. The instruments were validated using exploratory factor analyses, reliability analysis of identified scales and assessing the association between reliable scales and global ratings. We investigated opportunities for improvement by combining suboptimal experience with patient priority. Sixteen dialysis centres participated in our study. The pilot CQ index for CHD care consisted of 71 questions. Based on data of 592 respondents, we identified 42 core experience items in 10 scales with Cronbach's α ranging from 0.38 to 0.88; five were reliable (α ≥ 0.70). The instrument identified information on centres' fire procedures as the aspect of care exhibiting the biggest opportunity for improvement. The pilot CQ index PHHD comprised 56 questions. The response of 248 patients yielded 31 core experience items in nine scales with Cronbach's α ranging between 0.53 and 0.85; six were reliable. Information on kidney transplantation during pre-dialysis showed most room for improvement. However, for both types of care, opportunities for improvement were mostly limited. The CQ index reliably and validly captures dialysis patient experience. Overall, most care aspects showed limited room for improvement, mainly because patients participating in our study rated their experience to be optimal. To evaluate items with high priority, but with which relatively few patients have experience, more qualitative instruments should be considered.
The frictional strength of talc gouge in high-velocity shear experiments
NASA Astrophysics Data System (ADS)
Chen, Xiaofeng; Elwood Madden, Andrew S.; Reches, Ze'ev
2017-05-01
Talc is present in several large-scale fault zones worldwide and is mineralogically stable at temperature of the upper crust. It is therefore necessary to gain a better understanding of the frictional behavior of talc under a wide range of slip velocity conditions occurring during the seismic cycle. We analyzed the frictional and structural characteristics of room-dry and water-saturated talc gouge by shear experiments on a confined gouge layer at slip velocity range of 0.002-0.66 m/s and normal stress up to 4.1 MPa. Room-dry talc showed a distinct slip-strengthening with the initial friction coefficient of μ 0.4 increased systematically to μ 1 at slip distance D > 1 m. Room-dry talc also displayed velocity-strengthening at slip distances shorter than 1 m. The water-saturated talc gouge displayed systematic low frictional strength of μ = 0.1-0.3 for the entire experimental range, with clear velocity-strengthening behavior with positive (a-b) values (rate dependence parameter of rate and state friction) of 0.01-0.04. The microstructural analyses revealed distributed shear and systematic dilation (up to 50%) for the room-dry talc, in contrast to the extreme slip localization and strong shear compaction for water-saturated talc. We propose that talc frictional strength is controlled by lubrication along cleavage surfaces that is facilitated by adsorbed water (room-dry) and surplus water (water-saturated). This mechanism can explain our experimental observations of slip-strengthening and velocity-strengthening for both types of talc gouge, as well as other clay minerals. It is thus expected that talc presence in fault zones would enhance creep and inhibit unstable slip.
Ng, Charis W L; Tan, Woan Shin; Gunapal, Pradeep P G; Wong, Lai Yin; Heng, Bee Hoon
2014-12-01
Depression in the elderly is a major public health issue. Socioeconomic status (SES) and social support are strong risk factors for depression. This study aimed to investigate the influence of SES and social support in elderly depression, and the modifying effect of social support on the relationship between SES and depression. A community-based survey was conducted on residents≥60 years old. Depressive symptoms were determined with scores≥5 using the 15-item Geriatric Depression Scale (GDS). Multivariable logistic regression was performed to determine the odds ratio (OR) of depressive symptoms with respect to SES and social support, and interaction terms between the two variables. Of 2447 responses analysed, 188 (7.8%) respondents had depressive symptoms. Living in 2-room housing, living alone/with a domestic helper, infrequent leisure time with children/grandchildren or being childless, and feeling socially isolated were independently associated with depressive symptoms. Relative to residents living with spouse and children in 4-/5-room housing, the highest ORs for depressive symptoms were those living with spouse and children in 2-room (OR: 3.06, P<0.05), followed by living with children only in 3-room (OR: 2.98, P<0.05), and living alone/with a domestic helper in 4-/5-room (OR: 2.73, P<0.05). Living with spouse only appears to buffer against depressive symptoms across socioeconomic classes, although the effect was not statistically significant. Low social support and low SES significantly increased the odds of depressive symptoms. The moderating effect of social support on depression was however not consistent across SES groups. Specific interventions need to target different SES groups to better help older adults at risk of developing depression.
van Dijk, A M; van Weert, J C M; Dröes, R M
2012-12-01
Recently, a new communication method was introduced in nursing homes for people with dementia. This so-called Veder Method, developed by professional actors with former educational background in care,combines proven effective emotion-oriented care methods, like reminiscence,with theatrical stimuli like songs and poetry. The method is applied during theatre shows and living room theatre activities. In this exploratory study the surplus value of a living room theatre activity according to the Veder method compared to a reminiscence group activity was evaluated. Within a quasi experimental design, three groups of nursing home residents with dementia were compared: Experimental group 1 (E1; N=64)joined a 'living room theatre activity' offered by trained caregivers. Experimental group 2 (E2; N=31) joined a 'living room theatre activity' offered by professional actors. The control group (N=52) received a reminiscence group activity. Behaviour, mood and quality of life were measured using standardized observation scales at three points in time: (T1) pretest; (T2)during the intervention and; (T3) posttest, two hours after the intervention. During and after the intervention, positive effects were found in favour of E2 on behaviour (i.e. laughing, recalled memories), mood (i.e. happy/content) and quality of life (i.e. social involvement, feeling at home). A living room theatre activity according to the Veder Method has more positive effect on nursing home residents compared to a normal reminiscence group activity, if offered by professional actors.This article is a slightly edited translation of Does theatre improve the quality of life of people with dementia? International Psychogeriatrics2012;24: 36r381 by the same authors.
Ma, Meng; Fallavollita, Pascal; Habert, Séverine; Weidert, Simon; Navab, Nassir
2016-06-01
In the modern day operating room, the surgeon performs surgeries with the support of different medical systems that showcase patient information, physiological data, and medical images. It is generally accepted that numerous interactions must be performed by the surgical team to control the corresponding medical system to retrieve the desired information. Joysticks and physical keys are still present in the operating room due to the disadvantages of mouses, and surgeons often communicate instructions to the surgical team when requiring information from a specific medical system. In this paper, a novel user interface is developed that allows the surgeon to personally perform touchless interaction with the various medical systems, switch effortlessly among them, all of this without modifying the systems' software and hardware. To achieve this, a wearable RGB-D sensor is mounted on the surgeon's head for inside-out tracking of his/her finger with any of the medical systems' displays. Android devices with a special application are connected to the computers on which the medical systems are running, simulating a normal USB mouse and keyboard. When the surgeon performs interaction using pointing gestures, the desired cursor position in the targeted medical system display, and gestures, are transformed into general events and then sent to the corresponding Android device. Finally, the application running on the Android devices generates the corresponding mouse or keyboard events according to the targeted medical system. To simulate an operating room setting, our unique user interface was tested by seven medical participants who performed several interactions with the visualization of CT, MRI, and fluoroscopy images at varying distances from them. Results from the system usability scale and NASA-TLX workload index indicated a strong acceptance of our proposed user interface.
Speech Adjustments for Room Acoustics and Their Effects on Vocal Effort.
Bottalico, Pasquale
2017-05-01
The aims of the present study are (1) to analyze the effects of the acoustical environment and the voice style on time dose (D t_p ) and fundamental frequency (mean f 0 and standard deviation std_f 0 ) while taking into account the effect of short-term vocal fatigue and (2) to predict the self-reported vocal effort from the voice acoustical parameters. Ten male and ten female subjects were recorded while reading a text in normal and loud styles, in three rooms-anechoic, semi-reverberant, and reverberant-with and without acrylic glass panels 0.5 m from the mouth, which increased external auditory feedback. Subjects quantified how much effort was required to speak in each condition on a visual analogue scale after each task. (Aim1) In the loud style, D t_p , f 0 , and std_f 0 increased. The D t_p was higher in the reverberant room compared to the other two rooms. Both genders tended to increase f 0 in less reverberant environments, whereas a more monotonous speech was produced in rooms with greater reverberation. All three voice parameters increased with short-term vocal fatigue. (Aim2) A model of the vocal effort to acoustic vocal parameters is proposed. The sound pressure level contributed to 66% of the variance explained by the model, followed by the f 0 (30%) and the modulation in amplitude (4%). The results provide insight into how voice acoustical parameters can predict vocal effort. In particular, it increased when SPL and f 0 increased and when the amplitude voice modulation decreased. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Growth Stresses in Thermally Grown Oxides on Nickel-Based Single-Crystal Alloys
NASA Astrophysics Data System (ADS)
Rettberg, Luke H.; Laux, Britta; He, Ming Y.; Hovis, David; Heuer, Arthur H.; Pollock, Tresa M.
2016-03-01
Growth stresses that develop in α-Al2O3 scale that form during isothermal oxidation of three Ni-based single crystal alloys have been studied to elucidate their role in coating and substrate degradation at elevated temperatures. Piezospectroscopy measurements at room temperature indicate large room temperature compressive stresses in the oxides formed at 1255 K or 1366 K (982 °C or 1093 °C) on the alloys, ranging from a high of 4.8 GPa for René N4 at 1366 K (1093 °C) to a low of 3.8 GPa for René N5 at 1255 K (982 °C). Finite element modeling of each of these systems to account for differences in coefficients of thermal expansion of the oxide and substrate indicates growth strains in the range from 0.21 to 0.44 pct at the oxidation temperature, which is an order of magnitude higher than the growth strains measured in the oxides on intermetallic coatings that are typically applied to these superalloys. The magnitudes of the growth strains do not scale with the parabolic oxidation rate constants measured for the alloys. Significant spatial inhomogeneities in the growth stresses were observed, due to (i) the presence of dendritic segregation and (ii) large carbides in the material that locally disrupts the structure of the oxide scale. The implications of these observations for failure during cyclic oxidation, fatigue cycling, and alloy design are considered.
Earthquake stress drop and laboratory-inferred interseismic strength recovery
Beeler, N.M.; Hickman, S.H.; Wong, T.-F.
2001-01-01
We determine the scaling relationships between earthquake stress drop and recurrence interval tr that are implied by laboratory-measured fault strength. We assume that repeating earthquakes can be simulated by stick-slip sliding using a spring and slider block model. Simulations with static/kinetic strength, time-dependent strength, and rate- and state-variable-dependent strength indicate that the relationship between loading velocity and recurrence interval can be adequately described by the power law VL ??? trn, where n=-1. Deviations from n=-1 arise from second order effects on strength, with n>-1 corresponding to apparent time-dependent strengthening and n<-1 corresponding to weakening. Simulations with rate and state-variable equations show that dynamic shear stress drop ????d scales with recurrence as d????d/dlntr ??? ??e(b-a), where ??e is the effective normal stress, ??=??/??e, and (a-b)=d??ss/dlnV is the steady-state slip rate dependence of strength. In addition, accounting for seismic energy radiation, we suggest that the static shear stress drop ????s scales as d????s/dlntr ??? ??e(1+??)(b-a), where ?? is the fractional overshoot. The variation of ????s with lntr for earthquake stress drops is somewhat larger than implied by room temperature laboratory values of ?? and b-a. However, the uncertainty associated with the seismic data is large and the discrepancy between the seismic observations and the rate of strengthening predicted by room temperature experiments is less than an order of magnitude. Copyright 2001 by the American Geophysical Union.
Display device for indicating the value of a parameter in a process plant
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1993-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Indicator system for advanced nuclear plant control complex
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1993-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Indicator system for a process plant control complex
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1993-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Console for a nuclear control complex
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1993-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Alarm system for a nuclear control complex
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1994-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Advanced nuclear plant control complex
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1993-01-01
An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.
Strontium Removal: Full-Scale Ohio Demonstrations
The objectives of this presentation are to present a brief overview of past bench-scale research to evaluate the impact lime softening on strontium removal from drinking water and present full-scale drinking water treatment studies to impact of lime softening and ion exchange sof...
49 CFR 239.105 - Debriefing and critique.
Code of Federal Regulations, 2014 CFR
2014-10-01
... emergency situation or full-scale simulation to determine the effectiveness of its emergency preparedness... passenger train emergency situation or full-scale simulation. To the extent practicable, all on-board...-scale simulation shall participate in the session either: (1) In person; (2) Offsite via teleconference...
Clown doctors as a treatment for preoperative anxiety in children: a randomized, prospective study.
Vagnoli, Laura; Caprilli, Simona; Robiglio, Arianna; Messeri, Andrea
2005-10-01
The induction of anesthesia is one of the most stressful moments for a child who must undergo surgery: it is estimated that 60% of children suffer anxiety in the preoperative period. Preoperative anxiety is characterized by subjective feelings of tension, apprehension, nervousness, and worry. These reactions reflect the child's fear of separation from parents and home environment, as well as of loss of control, unfamiliar routines, surgical instruments, and hospital procedures. High levels of anxiety have been identified as predictors of postoperative troubles that can persist for 6 months after the procedure. Both behavioral and pharmacologic interventions are available to treat preoperative anxiety in children. The aim of this study was to investigate the effects of the presence of clowns on a child's preoperative anxiety during the induction of anesthesia and on the parent who accompanies him/her until he/she is asleep. The sample was composed of 40 subjects (5-12 years of age) who had to undergo minor day surgery and were assigned randomly to the clown group (N = 20), in which the children were accompanied in the preoperative room by the clowns and a parent, or the control group (N = 20), in which the children were accompanied by only 1 of his/her parents. The anxiety of the children in the preoperative period was measured through the Modified Yale Preoperative Anxiety Scale instrument (observational behavioral checklist to measure the state anxiety of young children), and the anxiety of the parents was measured with the State-Trait Anxiety Inventory (Y-1/Y-2) instrument (self-report anxiety behavioral instrument that measures trait/baseline and state/situational anxiety in adults). In addition, a questionnaire for health professionals was developed to obtain their opinion about the presence of clowns during the induction of anesthesia, and a self-evaluation form was developed to be filled out by the clowns themselves about their interactions with the child. The clown group was significantly less anxious during the induction of anesthesia compared with the control group. In the control group there was an increased level of anxiety in the induction room in comparison to in the waiting room; in the clown group anxiety was not significantly different in the 2 locations. The questionnaire for health professionals indicated that the clowns were a benefit to the child, but the majority of the staff was opposed to continuing the program because of perceived interference with the procedures of the operating room. The correlation between the scores of the form to self-evaluate the effectiveness of the clowns and of the Modified Yale Preoperative Anxiety Scale is significant for both the waiting room and induction room. This study shows that the presence of clowns during the induction of anesthesia, together with the child's parents, was an effective intervention for managing children's and parents' anxiety during the preoperative period. We would encourage the promotion of this form of distraction therapy in the treatment of children requiring surgery, but the resistance of medical personnel make it very difficult to insert this program in the activity of the operating room.
Closed-Loop Acoustic Control of Reverberant Room for Satellite Environmental Testing
NASA Astrophysics Data System (ADS)
Janssens, Karl; Bianciardi, Fabio; Sabbatini, Danilo; Debille, Jan; Carrella, Alex
2012-07-01
The full satellite acoustic test is an important milestone in a satellite launch survivability verification campaign. This test is required to verify the satellite’s mechanical design against the high-level acoustic loads induced by the launch vehicle during the atmospheric flight. During the test, the satellite is subjected to a broadband diffuse acoustic field, reproducing the pressure levels observed during launch. The excitation is in most cases provided by a combination of horns for the low frequencies and noise generators for the higher frequencies. Acoustic control tests are commonly performed in reverberant rooms, controlling the sound pressure levels in third octave bands over the specified target spectrum. This paper discusses an automatic feedback control system for acoustic control of large reverberation rooms for satellite environmental testing. The acoustic control system consists of parallel third octave PI (Proportional Integral) feedback controllers that take the reverberation characteristics of the room into consideration. The drive output of the control system is shaped at every control step based on the comparison of the average third octave noise spectrum, measured from a number of microphones in the test room, with the target spectrum. Cross-over filters split the output drive into band- limited signals to feed each of the horns. The control system is realized in several steps. In the first phase, a dynamic process model is developed, including the non-linear characteristics of the horns and the reverberant properties of the room. The model is identified from dynamic experiments using system identification techniques. In the next phase, an adequate control strategy is designed which is capable of reaching the target spectrum in the required time period without overshoots. This control strategy is obtained from model-in-the-loop (MIL) simulations, evaluating the performance of various potential strategies. Finally, the proposed strategy is implemented in real-time and its control performance tested and validated.
NASA Technical Reports Server (NTRS)
Squires, P. K.
1982-01-01
Reasons for lack of correlation between data from a fifth-scale wind tunnel test of the Bell Helicopter Textron Model 222 and a full-scale test of the model 222 prototype in the NASA Ames 40-by 80-foot tunnel were investigated. This investigation centered around a carefully designed fifth-scale wind tunnel test of an accurately contoured model of the Model 222 prototype mounted on a replica of the full-scale mounting system. The improvement in correlation for drag characteristics in pitch and yaw with the fifth-scale model mounted on the replica system is shown. Interference between the model and mounting system was identified as a significant effect and was concluded to be a primary cause of the lack of correlation in the earlier tests.
Magnetically tunable graphene-based reflector under linear polarized incidence at room temperature
NASA Astrophysics Data System (ADS)
Yang, Liang; Tian, Jing; Giddens, Henry; Poumirol, Jean-Marie; Wu, JingBo; Kuzmenko, Alexey B.; Hao, Yang
2018-04-01
At the terahertz spectrum, the 2D material graphene has diagonal and Hall conductivities in the presence of a magnetic field. These peculiar properties provide graphene-based structures with a magnetically tunable response to electromagnetic waves. In this work, the absolute reflection intensity was measured for a graphene-based reflector illuminated by linearly polarized incident waves at room temperature, which demonstrated the intensity modulation depth (IMD) under different magnetostatic biases by up to 15%. Experimental data were fitted and analyzed by a modified equivalent circuit model. In addition, as an important phenomenon of the graphene gyrotropic response, Kerr rotation is discussed according to results achieved from full-wave simulations. It is concluded that the IMD is reduced for the best Kerr rotation in the proposed graphene-based reflector.
NASA Technical Reports Server (NTRS)
Podboy, Gary G.; Bridges, James E.; Henderson, Brenda S.
2010-01-01
A 48-microphone planar phased array system was used to acquire jet noise source localization data on both a full-scale F404-GE-F400 engine and on a 1/4th scale model of a F400 series nozzle. The full-scale engine test data show the location of the dominant noise sources in the jet plume as a function of frequency for the engine in both baseline (no chevron) and chevron configurations. Data are presented for the engine operating both with and without afterburners. Based on lessons learned during this test, a set of recommendations are provided regarding how the phased array measurement system could be modified in order to obtain more useful acoustic source localization data on high-performance military engines in the future. The data obtained on the 1/4th scale F400 series nozzle provide useful insights regarding the full-scale engine jet noise source mechanisms, and document some of the differences associated with testing at model-scale versus fullscale.
2006-03-31
Nonnegative Dynamical Sys- tems................................................. 18 2.10. Adaptive Control for General Anesthesia and Intensive Care...Unit Sedation 20 2.11. Neural Network Adaptive Control for Intensive Care Unit Sedation and In- traoperative Anesthesia ...control for operating room hypnosis and intefisive care unit sedation. 1.3. Goals of this Report The main goal of this report is to summarize the
Global Behavior in Large Scale Systems
2013-12-05
release. AIR FORCE RESEARCH LABORATORY AF OFFICE OF SCIENTIFIC RESEARCH (AFOSR)/RSL ARLINGTON, VIRGINIA 22203 AIR FORCE MATERIEL COMMAND AFRL-OSR-VA...and Research 875 Randolph Street, Suite 325 Room 3112, Arlington, VA 22203 December 3, 2013 1 Abstract This research attained two main achievements: 1...microscopic random interactions among the agents. 2 1 Introduction In this research we considered two main problems: 1) large deviation error performance in
Time-lapse videos for physics education: specific examples
NASA Astrophysics Data System (ADS)
Vollmer, Michael; Möllmann, Klaus-Peter
2018-05-01
There are many physics experiments with long time scales such that they are usually neither shown in the physics class room nor in student labs. However, they can be easily recorded with time-lapse cameras and the respective time-lapse videos allow qualitative and/or quantitative analysis of the underlying physics. Here, we present some examples from thermal physics (melting, evaporation, cooling) as well as diffusion processes
Strongly luminescent InP/ZnS core-shell nanoparticles.
Haubold, S; Haase, M; Kornowski, A; Weller, H
2001-05-18
The wide-bandgap semiconducting material, zinc sulfide, has been coated on indium phosphide nanoclusters to a 1-2-Å thickness. The resulting InP-ZnS core-shell particle (as shown in the TEM image; scale 1 cm=5 nm) exhibits bright luminescence at room temperature with quantum efficiencies as high as 23 %. © 2001 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.
Synchronization of natural convection in thermostatically-controlled adjacent cavities
NASA Astrophysics Data System (ADS)
Chavez-Martinez, Rafael; Sanchez-Lopez, Mario; Solorio-Ordaz, Francisco Javier; Sen, Mihir
2017-11-01
Synchronization is a phenomenon observed in complex dynamical systems. It was first noticed by Huygens in the 17th century, and since then has been observed in systems of different types such as mechanical, biological and social. In thermal systems, numerical and analytical studies have found that two or more similar heat sources, with independent thermostatic temperature control and communicating with each other through a common interface, can have temperature oscillations. In the present study, laboratory experiments were carried out to study the thermal synchronization in two cuboid rooms separated by a common wall. Computer-based thermostats independently control the temperature of each cavity. The experiments show the effect of the ambient temperature and the initial condition in the cavities on the phase difference Δϕ . The results demonstrate in-phase and out-of-phase synchronization. An increase of the temperature difference between the cavity and the ambient, ΔT , increases Δϕ . When ΔT <2° C, Δϕ oscillates around zero. Δϕ is negative independently of the initial condition. The results of these experiments will be useful in the desing of heating in full-scale buildings. This work is supported by DGAPA-UNAM Grant PAPIIT-IN114216.
Simulated and Experimental Damping Properties of a SMA/Fiber Glass Laminated Composite
NASA Astrophysics Data System (ADS)
Arnaboldi, S.; Bassani, P.; Biffi, C. A.; Tuissi, A.; Carnevale, M.; Lecis, N.; Loconte, A.; Previtali, B.
2011-07-01
In this article, an advanced laminated composite is developed, combining the high damping properties of shape memory alloy (SMA) with mechanical properties and light weight of a glass-fiber reinforced polymer. The composite is formed by stacking a glass-fiber reinforced epoxy core between two thin patterned strips of SMA alloy, and two further layers of fiber-glass reinforced epoxy. The bars of the laminated composite were assembled and cured in autoclave. The patterning was designed to enhance the interface adhesion between matrix and SMA inserts and optimally exploit the damping capacity of the SMA thin ribbons. The patterned ribbons of the SMA alloy were cut by means of a pulsed fiber laser source. Damping properties at different amplitudes on full scale samples were investigated at room temperature with a universal testing machine through dynamic tension tests, while temperature dependence was investigated by dynamic mechanical analyses (DMA) on smaller samples. Experimental results were used in conjunction with FEM analysis to optimize the geometry of the inserts. Experimental decay tests on the laminated composite have been carried out to identify the adimensional damping value related to their first flexural mode.
Using micro-3D printing to build acoustically driven microswimmers.
NASA Astrophysics Data System (ADS)
Bertin, Nicolas; Stephan, Olivier; Marmottant, Philippe; Spelman, Tamsin; Lauga, Eric; Dyfcom Team; Complex; Biological Fluids Team
2015-11-01
With no protection, a micron-sized free air bubble at room temperature in water has a life span shorter than a few tens of seconds. Using two-photon lithography, which is similar to 3D printing at the micron scale, we can build ``armors'' for these bubbles: micro-capsules with an opening to contain the bubble and extend its life to several hours in biological buffer solutions. When excited by an ultrasound transducer, a 20 μm bubble performs large amplitude oscillations in the capsule opening and generates a powerful acoustic streaming flow (velocity up to dozens of mm/s). A collaboration with the Dept. of Applied Mathematics and Theoretical Physics, University of Cambridge, is helping us predict the true resonance of these capsules and the full surrounding streaming flow. The present Bubbleboost project aims at creating red blood cell sized capsules (~ 10-20 μm) that can move on their own with a non-contact acoustic excitation for drug delivery applications. Another application of this research is in microfluidics: we are able to fabricate fields of capsules able to generate mixing effects in microchannels, or use the bubble-generated flow to guide passing objects at a junction. ERC Grant Agreement Bubbleboost no. 614655.
The High Temperature Tensile and Creep Behaviors of High Entropy Superalloy.
Tsao, Te-Kang; Yeh, An-Chou; Kuo, Chen-Ming; Kakehi, Koji; Murakami, Hideyuki; Yeh, Jien-Wei; Jian, Sheng-Rui
2017-10-04
This article presents the high temperature tensile and creep behaviors of a novel high entropy alloy (HEA). The microstructure of this HEA resembles that of advanced superalloys with a high entropy FCC matrix and L1 2 ordered precipitates, so it is also named as "high entropy superalloy (HESA)". The tensile yield strengths of HESA surpass those of the reported HEAs from room temperature to elevated temperatures; furthermore, its creep resistance at 982 °C can be compared to those of some Ni-based superalloys. Analysis on experimental results indicate that HESA could be strengthened by the low stacking-fault energy of the matrix, high anti-phase boundary energy of the strengthening precipitate, and thermally stable microstructure. Positive misfit between FCC matrix and precipitate has yielded parallel raft microstructure during creep at 982 °C, and the creep curves of HESA were dominated by tertiary creep behavior. To the best of authors' knowledge, this article is the first to present the elevated temperature tensile creep study on full scale specimens of a high entropy alloy, and the potential of HESA for high temperature structural application is discussed.
Laser-assisted heating of a plasmonic nanofluid in a microchannel
NASA Astrophysics Data System (ADS)
Walsh, Timothy
The work presented in this study analyses the theoretical modeling and experimentation of laser-assisted heating of plasmonic nanofluids (PNFs) in a microchannel for accurate, efficient, and ultra-fast heating of a microdroplet. Suspended plasmonic nanoparticles exhibit strong light absorption and scattering upon the excitation of localized surface plasmons (LSPs), resulting in intense and rapid photothermal heating. Several multi-stepped computational models were utilized to theoretically characterize and verify the laser-assisted heating behavior of gold nanoshells (GNS) and gold nanorod (GNR) plasmonic nanofluid droplets in a microchannel. From the experimental investigation, a full range of controllable steady-state temperatures, room temperature to 100°C, are confirmed to be achievable for the 780-nm-tuned plasmonic nanofluid. Droplet fluid heating is verified to occur as a result of LSP excitation, in time scales of milliseconds, and to be repeatable over many cycles. Additionally, the significance and effects of parameters in the process, such as nanoparticle structure, volumetric concentration, microchannel depth, and laser power density are established. The obtained results in this research may be integrated into other existing microfluidic technologies and biological techniques, such as the polymerase chain reaction, where accurate and ultra-fast heating of microdroplets in a microchannel can greatly improve efficiency.
NASA Astrophysics Data System (ADS)
Oumaya, Toru; Nakamura, Akira; Onojima, Daisuke; Takenaka, Nobuyuki
The pressurizer spray line of PWR plants cools reactor coolant by injecting water into pressurizer. Since the continuous spray flow rate during commercial operation of the plant is considered insufficient to fill the pipe completely, there is a concern that a water surface exists in the pipe and may periodically sway. In order to identify the flow regimes in spray line piping and assess their impact on pipe structure, a flow visualization experiment was conducted. In the experiment, air was used substituted for steam to simulate the gas phase of the pressurizer, and the flow instability causing swaying without condensation was investigated. With a full-scale mock-up made of acrylic, flow under room temperature and atmospheric pressure conditions was visualized, and possible flow regimes were identified based on the results of the experiment. Three representative patterns of swaying of water surface were assumed, and the range of thermal stress fluctuation, when the surface swayed instantaneously, was calculated. With the three patterns of swaying assumed based on the visualization experiment, it was confirmed that the thermal stress amplitude would not exceed the fatigue endurance limit prescribed in the Japanese Design and Construction Code.
Wernisch, Stefanie; Trapp, Oliver; Lindner, Wolfgang
2013-09-17
The interconversion of cis and trans isomers of dipeptides containing C-terminal proline was studied by dynamic chromatography on zwitterionic chiral stationary phases at temperatures ranging from -15°C to +45°C The cis-trans isomers could be separated below 0°C and above 0-10°C plateau formation and peak coalescence phenomena occurred, which is characteristic for a dynamic process at the time-scale of partitioning. At and above room temperature, full coalescence was observed, which allowed separations of enantiomers without interference from interconversion effects. Analysis of the dynamic elution profiles of the interconverting peptides allowed the determination of isomerization rate constants and thermodynamic activation parameters (isomerization enthalpy, entropy and activation energy). In accordance with established results, isomerization rates and thermodynamic parameters were found to depend on the nature of the N-terminal amino acid. Isomerization barriers were only slightly lower than values determined with other methods but significant differences in the relative contributions of the activation enthalpy and entropy as well as isomerization rates pointed toward selector-moderated isomerization dynamics. Copyright © 2013 Elsevier B.V. All rights reserved.
A continuum dislocation dynamics framework for plasticity of polycrystalline materials
NASA Astrophysics Data System (ADS)
Askari, Hesam Aldin
The objective of this research is to investigate the mechanical response of polycrystals in different settings to identify the mechanisms that give rise to specific response observed in the deformation process. Particularly the large deformation of magnesium alloys and yield properties of copper in small scales are investigated. We develop a continuum dislocation dynamics framework based on dislocation mechanisms and interaction laws and implement this formulation in a viscoplastic self-consistent scheme to obtain the mechanical response in a polycrystalline system. The versatility of this method allows various applications in the study of problems involving large deformation, study of microstructure and its evolution, superplasticity, study of size effect in polycrystals and stochastic plasticity. The findings from the numerical solution are compared to the experimental results to validate the simulation results. We apply this framework to study the deformation mechanisms in magnesium alloys at moderate to fast strain rates and room temperature to 450 °C. Experiments for the same range of strain rates and temperatures were carried out to obtain the mechanical and material properties, and to compare with the numerical results. The numerical approach for magnesium is divided into four main steps; 1) room temperature unidirectional loading 2) high temperature deformation without grain boundary sliding 3) high temperature with grain boundary sliding mechanism 4) room temperature cyclic loading. We demonstrate the capability of our modeling approach in prediction of mechanical properties and texture evolution and discuss the improvement obtained by using the continuum dislocation dynamics method. The framework was also applied to nano-sized copper polycrystals to study the yield properties at small scales and address the observed yield scatter. By combining our developed method with a Monte Carlo simulation approach, the stochastic plasticity at small length scales was studied and the sources of the uncertainty in the polycrystalline structure are discussed. Our results suggest that the stochastic response is mainly because of a) stochastic plasticity due to dislocation substructure inside crystals and b) the microstructure of the polycrystalline material. The extent of the uncertainty is correlated to the "effective cell length" in the sampling procedure whether using simulations and experimental approach.
1990-02-15
electrical activity mapping procedures. It is necessary to employ approximately 20 electrodes to conduct full- scale brain mapping procedures, using a...animal groups, likewise, showed no observable differences in the animal’s exploratory behavior, nuzzle response, lid-corneal and ear reflexes, pain ...SPECIFICATIONS FOR THE ENVIRONICS SERIES 100 GAS STANDARDS GENERATOR Accuracy of Flow 0.15 % of Full Scale Linearity 0.15 % of Full Scale Repeatability 0.10
Full-Scale Testing of Thermoplastic Composite I-Beams for Bridges
2017-06-01
ER D C/ CE RL T R- 17 -1 8 ACSIM Technology Standards Group Full-Scale Testing of Thermoplastic Composite I-Beams for Bridges Co ns tr...default. ACSIM Technology Standards Group ERDC/CERL TR-17-18 June 2017 Full-Scale Testing of Thermoplastic Composite I-Beams for Bridges Ghassan... tests were con- ducted on commercially available, thermoplastic polymer composite I- beams at U.S. Army Corps of Engineers, Engineer Research and
Converting Hangar High Expansion Foam Systems to Prevent Cockpit Damage: Full-Scale Validation Tests
2017-09-01
AFCEC-CO-TY-TR-2018-0001 CONVERTING HANGAR HIGH EXPANSION FOAM SYSTEMS TO PREVENT COCKPIT DAMAGE: FULL-SCALE VALIDATION TESTS Gerard G...REPORT NUMBER(S) 12. DISTRIBUTION/ AVAILABILITY STATEMENT 13. SUPPLEMENTARY NOTES 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: a. REPORT b...09-2017 Final Test Report May 2017 Converting Hangar High Expansion Foam Systems to Prevent Cockpit Damage: Full-Scale Validation Tests N00173-15-D
Improvement of CFD Methods for Modeling Full Scale Circulating Fluidized Bed Combustion Systems
NASA Astrophysics Data System (ADS)
Shah, Srujal; Klajny, Marcin; Myöhänen, Kari; Hyppänen, Timo
With the currently available methods of computational fluid dynamics (CFD), the task of simulating full scale circulating fluidized bed combustors is very challenging. In order to simulate the complex fluidization process, the size of calculation cells should be small and the calculation should be transient with small time step size. For full scale systems, these requirements lead to very large meshes and very long calculation times, so that the simulation in practice is difficult. This study investigates the requirements of cell size and the time step size for accurate simulations, and the filtering effects caused by coarser mesh and longer time step. A modeling study of a full scale CFB furnace is presented and the model results are compared with experimental data.