Sample records for full thickness human

  1. Full-Thickness Skin Wound Healing Using Human Placenta-Derived Extracellular Matrix Containing Bioactive Molecules

    PubMed Central

    Choi, Ji Suk; Kim, Jae Dong; Yoon, Hyun Soo

    2013-01-01

    The human placenta, a complex organ, which facilitates exchange between the fetus and the mother, contains abundant extracellular matrix (ECM) components and well-preserved endogenous growth factors. In this study, we designed a new dermal substitute from human placentas for full-thickness wound healing. Highly porous, decellularized ECM sheets were fabricated from human placentas via homogenization, centrifugation, chemical and enzymatic treatments, molding, and freeze-drying. The physical structure and biological composition of human placenta-derived ECM sheets dramatically supported the regeneration of full-thickness wound in vivo. At the early stage, the ECM sheet efficiently absorbed wound exudates and tightly attached to the wound surface. Four weeks after implantation, the wound was completely closed, epidermic cells were well arranged and the bilayer structure of the epidermis and dermis was restored. Moreover, hair follicles and microvessels were newly formed in the ECM sheet-implanted wounds. Overall, the ECM sheet produced a dermal substitute with similar cellular organization to that of normal skin. These results suggest that human placenta-derived ECM sheets provide a microenvironment favorable to the growth and differentiation of cells, and positive modulate the healing of full-thickness wounds. PMID:22891853

  2. Topical Modulation of the Burn Wound Inflammatory Response to Improve Short and Long Term Outcomes

    DTIC Science & Technology

    2017-10-01

    casualty, treatment, organ failure, systemic inflammatory response syndrome , thermal injury, wound model, intervention 3. ACCOMPLISHMENTS:   What...thickness burns have a blister response. Using human eye or H&E studies, we did not observe any blisters in the pig model. However, the OCT...the deeper the partial thickness burn, the bigger the blister, until it gets close to full-thickness burns. The full-thickness burns are dry and

  3. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model.

    PubMed

    Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul

    2015-11-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.

  4. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model

    PubMed Central

    Park, Gi-Young; Lee, Sang Chul

    2015-01-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340

  5. Pre-vascularization Enhances Therapeutic Effects of Human Mesenchymal Stem Cell Sheets in Full Thickness Skin Wound Repair.

    PubMed

    Chen, Lei; Xing, Qi; Zhai, Qiyi; Tahtinen, Mitchell; Zhou, Fei; Chen, Lili; Xu, Yingbin; Qi, Shaohai; Zhao, Feng

    2017-01-01

    Split thickness skin graft (STSG) implantation is one of the standard therapies for full thickness wound repair when full thickness autologous skin grafts (FTG) or skin flap transplants are inapplicable. Combined transplantation of STSG with dermal substitute could enhance its therapeutic effects but the results remain unsatisfactory due to insufficient blood supply at early stages, which causes graft necrosis and fibrosis. Human mesenchymal stem cell (hMSC) sheets are capable of accelerating the wound healing process. We hypothesized that pre-vascularized hMSC sheets would further improve regeneration by providing more versatile angiogenic factors and pre-formed microvessels. In this work, in vitro cultured hMSC cell sheets (HCS) and pre-vascularized hMSC cell sheets (PHCS) were implanted in a rat full thickness skin wound model covered with an autologous STSG. Results demonstrated that the HCS and the PHCS implantations significantly reduced skin contraction and improved cosmetic appearance relative to the STSG control group. The PHCS group experienced the least hemorrhage and necrosis, and lowest inflammatory cell infiltration. It also induced the highest neovascularization in early stages, which established a robust blood micro-circulation to support grafts survival and tissue regeneration. Moreover, the PHCS grafts preserved the largest amount of skin appendages, including hair follicles and sebaceous glands, and developed the smallest epidermal thickness. The superior therapeutic effects seen in PHCS groups were attributed to the elevated presence of growth factors and cytokines in the pre-vascularized cell sheet, which exerted a beneficial paracrine signaling during wound repair. Hence, the strategy of combining STSG with PHCS implantation appears to be a promising approach in regenerative treatment of full thickness skin wounds.

  6. Creating a Full-thickness Choroidal Incision: An Ex Vivo Analysis of Human and Porcine Tissue Contraction Dynamics

    PubMed Central

    LoBue, Stephen A.; Yamada, Norihiro; Choi, Moon Jeong; Olsen, Timothy W.

    2017-01-01

    Purpose We hypothesized that the elastic nature of the choroid leads to tissue contraction following a full-thickness, sharp incision. Furthermore, we sought to quantify, measure, and compare tissue contraction in ex vivo porcine globes and human globes of various ages using predetermined variables. Method A full-thickness, ex vivo choroidal incision was performed in either pig (n = 97) or human (n = 30) specimens. Variables included trephine diameter (1.5, 2.0, or 2.5 mm) versus a straight surgical blade, and temperature (1.7 °–4.4° vs. 36.6°F). Central centripetal and surround centrifugal tissue contractions were measured. Mean percentage tissue contraction was assessed as a ratio of trephine diameter to final tissue contraction measured immediately following each incision using a standardized device. Results For trephination in pig specimens, centripetal contraction ranged from 38% to 50% with a mean of 44%. Centrifugal contraction was approximately 15%. Human choroidal contraction was 39% and 15%, respectively, with a statistically significant inverse relationship to age (R2 = 0.35, P ≤ 0.01). Asymmetric contraction was noted when incisions were closer to choroidal attachment sites to the sclera, such as near vortex ampullae. Linear incisions resulted in contraction that correlated with incision length (R2 = 0.35, P ≤ 0.001). Conclusions A full-thickness choroidal incision results in significant tissue contraction. For circular incisions, the centripetal contraction approaches 50% of the original incision size. For linear incisions, the contraction corresponds directly with incision length. In human specimens, there is less contraction with advancing age. Translational Relevance Our findings have clinical relevance for choroidal biopsy, traumatic injury, and choroidal translocation surgery. PMID:29134136

  7. Expression of proliferative and inflammatory markers in a full-thickness human skin equivalent following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide

    PubMed Central

    Black, Adrienne T.; Hayden, Patrick J.; Casillas, Robert P.; Heck, Diane E.; Gerecke, Donald R.; Sinko, Patrick J.; Laskin, Debra L.; Laskin, Jeffrey D.

    2010-01-01

    Sulfur mustard is a potent vesicant that induces inflammation, edema and blistering following dermal exposure. To assess molecular mechanisms mediating these responses, we analyzed the effects of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide, on EpiDerm-FT™, a commercially available full-thickness human skin equivalent. CEES (100–1000 μM) caused a concentration-dependent increase in pyknotic nuclei and vacuolization in basal keratinocytes; at high concentrations (300–1000 μM), CEES also disrupted keratin filament architecture in the stratum corneum. This was associated with time-dependent increases in expression of proliferating cell nuclear antigen, a marker of cell proliferation, and poly(ADP-ribose) polymerase (PARP) and phosphorylated histone H2AX, markers of DNA damage. Concentration- and time-dependent increases in mRNA and protein expression of eicosanoid biosynthetic enzymes including COX-2, 5-lipoxygenase, microsomal PGE2 synthases, leukotriene (LT) A4 hydrolase and LTC4 synthase were observed in CEES-treated skin equivalents, as well as in antioxidant enzymes, glutathione S-transferases A1–2 (GSTA1–2), GSTA3 and GSTA4. These data demonstrate that CEES induces rapid cellular damage, cytotoxicity and inflammation in full-thickness skin equivalents. These effects are similar to human responses to vesicants in vivo and suggest that the full thickness skin equivalent is a useful in vitro model to characterize the biological effects of mustards and to develop potential therapeutics. PMID:20840853

  8. Expression of proliferative and inflammatory markers in a full-thickness human skin equivalent following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide.

    PubMed

    Black, Adrienne T; Hayden, Patrick J; Casillas, Robert P; Heck, Diane E; Gerecke, Donald R; Sinko, Patrick J; Laskin, Debra L; Laskin, Jeffrey D

    2010-12-01

    Sulfur mustard is a potent vesicant that induces inflammation, edema and blistering following dermal exposure. To assess molecular mechanisms mediating these responses, we analyzed the effects of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide, on EpiDerm-FT™, a commercially available full-thickness human skin equivalent. CEES (100-1000 μM) caused a concentration-dependent increase in pyknotic nuclei and vacuolization in basal keratinocytes; at high concentrations (300-1000 μM), CEES also disrupted keratin filament architecture in the stratum corneum. This was associated with time-dependent increases in expression of proliferating cell nuclear antigen, a marker of cell proliferation, and poly(ADP-ribose) polymerase (PARP) and phosphorylated histone H2AX, markers of DNA damage. Concentration- and time-dependent increases in mRNA and protein expression of eicosanoid biosynthetic enzymes including COX-2, 5-lipoxygenase, microsomal PGE₂ synthases, leukotriene (LT) A₄ hydrolase and LTC₄ synthase were observed in CEES-treated skin equivalents, as well as in antioxidant enzymes, glutathione S-transferases A1-2 (GSTA1-2), GSTA3 and GSTA4. These data demonstrate that CEES induces rapid cellular damage, cytotoxicity and inflammation in full-thickness skin equivalents. These effects are similar to human responses to vesicants in vivo and suggest that the full thickness skin equivalent is a useful in vitro model to characterize the biological effects of mustards and to develop potential therapeutics. Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Animal models for transdermal drug delivery.

    PubMed

    Panchagnula, R; Stemmer, K; Ritschel, W A

    1997-06-01

    The purpose of this investigation was to compare the permeation characteristics of two different compounds (extremely polar and nonpolar), i.e., tritium-labeled water (W) and 14C-labeled 7-hydroxycoumarin (7-OHC), among 16 different species, including human skin. Snake skin exhibited highest permeability for both W and 7-OHC. Permeability and lag time values of W and 7-OHC across Brattleboro rat and hairless guinea pig are very close to human skin. Skin thickness in micrometers (full thickness, epidermis and stratum corneum, and stratum corneum), and number of hair follicles present in each cm2 were determined for each species. There was no relationship between number of hair follicles and permeability values for both W and 7-OHC. The skin thickness (full) was related to the relative permeability values of W, whereas for 7-OHC it was not.

  10. 3D biomaterial matrix to support long term, full thickness, immuno-competent human skin equivalents with nervous system components.

    PubMed

    Vidal, Sarah E Lightfoot; Tamamoto, Kasey A; Nguyen, Hanh; Abbott, Rosalyn D; Cairns, Dana M; Kaplan, David L

    2018-04-24

    Current commercially available human skin equivalents (HSEs) are used for relatively short term studies (∼1 week) due in part to the time-dependent contraction of the collagen gel-based matrix and the limited cell types and skin tissue components utilized. In contrast, here we describe a new matrix consisting of a silk-collagen composite system that provides long term, stable cultivation with reduced contraction and degradation over time. This matrix supports full thickness skin equivalents which include nerves. The unique silk-collagen composite system preserves cell-binding domains of collagen while maintaining the stability and mechanics of the skin system for long-term culture with silk. The utility of this new composite protein-based biomaterial was demonstrated by bioengineering full thickness human skin systems using primary cells, including nerves and immune cells to establish an HSE with a neuro-immuno-cutaneous system. The HSEs with neurons and hypodermis, compared to in vitro skin-only HSEs controls, demonstrated higher secretion of pro-inflammatory cytokines. Proteomics analysis confirmed the presence of several proteins associated with inflammation across all sample groups, but HSEs with neurons had the highest amount of detected protein due to the complexity of the model. This improved, in vitro full thickness HSE model system utilizes cross-linked silk-collagen as the biomaterial and allows reduced reliance on animal models and provides a new in vitro tissue system for the assessment of chronic responses related to skin diseases and drug discovery. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Effects of ultrasound and sodium lauryl sulfate on the transdermal delivery of hydrophilic permeants: Comparative in vitro studies with full-thickness and split-thickness pig and human skin

    PubMed Central

    Seto, Jennifer E.; Polat, Baris E.; Lopez, Renata F.V.; Blankschtein, Daniel; Langer, Robert

    2010-01-01

    The simultaneous application of ultrasound and the surfactant sodium lauryl sulfate (referred to as US/SLS) to skin enhances transdermal drug delivery (TDD) in a synergistic mechanical and chemical manner. Since full-thickness skin (FTS) and split-thickness skin (STS) differ in mechanical strength, US/SLS treatment may have different effects on their transdermal transport pathways. Therefore, we evaluated STS as an alternative to the well-established US/SLS-treated FTS model for TDD studies of hydrophilic permeants. We utilized the aqueous porous pathway model to compare the effects of US/SLS treatment on the skin permeability and the pore radius of pig and human FTS and STS over a range of skin electrical resistivity values. Our findings indicate that the US/SLS-treated pig skin models exhibit similar permeabilities and pore radii, but the human skin models do not. Furthermore, the US/SLS-enhanced delivery of gold nanoparticles and quantum dots (two model hydrophilic macromolecules) is greater through pig STS than through pig FTS, due to the presence of less dermis that acts as an artificial barrier to macromolecules. In spite of greater variability in correlations between STS permeability and resistivity, our findings strongly suggest the use of 700-μm-thick pig STS to investigate the in vitro US/SLS-enhanced delivery of hydrophilic macromolecules. PMID:20346994

  12. Significantly Accelerated Wound Healing of Full-Thickness Skin Using a Novel Composite Gel of Porcine Acellular Dermal Matrix and Human Peripheral Blood Cells.

    PubMed

    Kuna, Vijay K; Padma, Arvind M; Håkansson, Joakim; Nygren, Jan; Sjöback, Robert; Petronis, Sarunas; Sumitran-Holgersson, Suchitra

    2017-02-16

    Here we report the fabrication of a novel composite gel from decellularized gal-gal-knockout porcine skin and human peripheral blood mononuclear cells (hPBMCs) for full-thickness skin wound healing. Decellularized skin extracellular matrix (ECM) powder was prepared via chemical treatment, freeze drying, and homogenization. The powder was mixed with culture medium containing hyaluronic acid to generate a pig skin gel (PSG). The effect of the gel in regeneration of full-thickness wounds was studied in nude mice. We found significantly accelerated wound closure already on day 15 in animals treated with PSG only or PSG + hPBMCs compared to untreated and hyaluronic acid-treated controls (p < 0.05). Addition of the hPBMCs to the gel resulted in marked increase of host blood vessels as well as the presence of human blood vessels. At day 25, histologically, the wounds in animals treated with PSG only or PSG + hPBMCs were completely closed compared to those of controls. Thus, the gel facilitated generation of new skin with well-arranged epidermal cells and restored bilayer structure of the epidermis and dermis. These results suggest that porcine skin ECM gel together with human cells may be a novel and promising biomaterial for medical applications especially for patients with acute and chronic skin wounds.

  13. Effects of ultrasound and sodium lauryl sulfate on the transdermal delivery of hydrophilic permeants: Comparative in vitro studies with full-thickness and split-thickness pig and human skin.

    PubMed

    Seto, Jennifer E; Polat, Baris E; Lopez, Renata F V; Blankschtein, Daniel; Langer, Robert

    2010-07-01

    The simultaneous application of ultrasound and the surfactant sodium lauryl sulfate (referred to as US/SLS) to skin enhances transdermal drug delivery (TDD) in a synergistic mechanical and chemical manner. Since full-thickness skin (FTS) and split-thickness skin (STS) differ in mechanical strength, US/SLS treatment may have different effects on their transdermal transport pathways. Therefore, we evaluated STS as an alternative to the well-established US/SLS-treated FTS model for TDD studies of hydrophilic permeants. We utilized the aqueous porous pathway model to compare the effects of US/SLS treatment on the skin permeability and the pore radius of pig and human FTS and STS over a range of skin electrical resistivity values. Our findings indicate that the US/SLS-treated pig skin models exhibit similar permeabilities and pore radii, but the human skin models do not. Furthermore, the US/SLS-enhanced delivery of gold nanoparticles and quantum dots (two model hydrophilic macromolecules) is greater through pig STS than through pig FTS, due to the presence of less dermis that acts as an artificial barrier to macromolecules. In spite of greater variability in correlations between STS permeability and resistivity, our findings strongly suggest the use of 700microm-thick pig STS to investigate the in vitro US/SLS-enhanced delivery of hydrophilic macromolecules. 2010 Elsevier B.V. All rights reserved.

  14. Expression profiles of phases 1 and 2 metabolizing enzymes in human skin and the reconstructed skin models Episkin and full thickness model from Episkin.

    PubMed

    Luu-The, Van; Duche, Daniel; Ferraris, Corinne; Meunier, Jean-Roch; Leclaire, Jacques; Labrie, Fernand

    2009-09-01

    Episkin and full thickness model from Episkin (FTM) are human skin models obtained from in vitro growth of keratinocytes into the five typical layers of the epidermis. FTM is a full thickness reconstructed skin model that also contains fibroblasts seeded in a collagen matrix. To assess whether enzymes involved in chemical detoxification are expressed in Episkin and FTM and how their levels compare with the human epidermis, dermis and total skin. Quantification of the mRNA expression levels of phases 1 and 2 metabolizing enzymes in cultured Episkin and FTM and human epidermis, dermis and total skin using Realtime PCR. The data show that the expression profiles of 61 phases 1 and 2 metabolizing enzymes in Episkin, FTM and epidermis are generally similar, with some exceptions. Cytochrome P450-dependent enzymes and flavin monooxygenases are expressed at low levels, while phase 2 metabolizing enzymes are expressed at much higher levels, especially, glutathione-S-transferase P1 (GSTP1) catechol-O-methyl transferase (COMT), steroid sulfotransferase (SULT2B1b), and N-acetyl transferase (NAT5). The present study also identifies the presence of many enzymes involved in cholesterol, arachidonic acid, leukotriene, prostaglandin, eicosatrienoic acids, and vitamin D3 metabolisms. The present data strongly suggest that Episkin and FTM represent reliable and valuable in vitro human skin models for studying the function of phases 1 and 2 metabolizing enzymes in xenobiotic metabolisms. They could be used to replace invasive methods or laboratory animals for skin experiments.

  15. Fibrin gel as a scaffold for skin substitute – production and clinical experience.

    PubMed

    Kljenak, Antun; Tominac Trcin, Mirna; Bujić, Marina; Dolenec, Tamara; Jevak, Martina; Mršić, Gordan; Zmiš, Gordana; Barčot, Zoran; Muljačić, Ante; Popović, Maja

    2016-06-01

    The purpose of this study was to create a fibrin-based human skin substitute in vitro with epidermal and dermal component and to assess its healing potential in deep partial and full thickness burns. Fibrin scaffolds were prepared from commercial fibrin glue kits. Human fibroblasts were cultured in fibrin gel. Human keratinocytes were seeded on the top of the gel. Viability of cells was determined fluorimetrically. Scanning electron microscope and immunocytochemistry analysis of cultured cells were performed. After hydrosurgical preparation of deep burn necrotic tissue, wound bed was prepared for skin substitutes. Progress of healing was documented using visual estimation and photos. Scanning electron microscope images showed good cell attachment and colony spreading of keratinocytes and fibroblasts on fibrin scaff old. Immunofluorescent staining of cell cultures on fibrin scaffold showed expression of vimentin, a marker of fibroblast cells, cytokeratin 19, a marker of epithelial stem cells, as well as involucrin, a marker of differentiated keratinocytes. Clinical results clearly showed that appearance of the skin did not differ significantly from the areas of transplanted skin using split-thickness skin graft techniques. In conclusion, using these fibrin-cultured autografts on massive full-thickness burn resulted in good healing.

  16. Cell suspension cultures of allogenic keratinocytes are efficient carriers for ex vivo gene transfer and accelerate the healing of full-thickness skin wounds by overexpression of human epidermal growth factor.

    PubMed

    Vranckx, Jan Jeroen; Hoeller, Daniela; Velander, Patrik E M; Theopold, Christoph F P; Petrie, Nicola; Takedo, Akira; Eriksson, Elof; Yao, Feng

    2007-01-01

    The concept of using growth factor therapy to induce wound repair has been endorsed in studies that show reduced growth factors in wound fluid from chronic and aged wounds. In this study, we used cell suspensions of allogenic keratinocytes as gene-delivery vehicles for human epidermal growth factor (hEGF) and analyzed their impact on wound repair in a porcine wound-healing model. Full-thickness wounds were created on the backs of six Yorkshire pigs and covered with a wound chamber to create a wet wound-healing environment. First, 5 x 10(5) allogenic, autogenic, or mixed keratinocytes were transplanted into wounds and healing parameters were analyzed. Second, we measured long-term reepithelialization and contraction rates from day 8 until day 35. In the third experiment, allogenic keratinocytes were transfected with an hEGF-expressing plasmid pCEP-hEGF and transplanted in full-thickness wounds to improve repair. Wounds treated with autogenic, allogenic, or mixed keratinocytes showed a significantly higher rate of reepithelialization relative to saline-treated control wounds. Repetitive biopsies indicated that the use of allogenic keratinocytes did not lead to long-term wound breakdown. Wounds treated with hEGF-expressing allogenic keratinocytes reepithelialized faster than wounds treated with allogenic keratinocytes or control wounds. With a peak hEGF expression of 920.8 pg/mL, hEGF was detectable until day 5 after transplantation compared with minimal hEGF expression in control wounds. This study shows that allogenic keratinocytes can serve as efficient gene transfer vehicles for ex vivo growth factor delivery to full-thickness wounds and overexpression of hEGF further improves reepithelialization rates.

  17. Efficacy and Safety of the Collagenase of the Bacterium Clostridium Histolyticum for the Treatment of Capsular Contracture after Silicone Implants: Ex-Vivo Study on Human Tissue.

    PubMed

    Fischer, Sebastian; Hirche, Christoph; Diehm, Yannick; Nuutila, Kristo; Kiefer, Jurij; Gazyakan, Emre; Bueno, Ericka M; Kremer, Thomas; Kneser, Ulrich; Pomahac, Bohdan

    2016-01-01

    The fibrotic capsule that surrounds silicone implants consists mainly of collagen. The FDA-approved collagenase of the bacterium clostridium histolyticum provides a reasonable treatment option. Safety and efficacy at the female breast site must be evaluated before clinical utilization. We incubated 20 samples of fibrotic capsule as well as 12 full thickness skin grafts harvested from the female breast site for 24 hours with different doses of collagenase. Outcome measures involved histological assessment of thickness and density of the capsule tissue as well as the skin grafts. Furthermore, we performed a collagen assay and immunohistochemistry staining for collagen subtypes. Collagenase treatment was able to degrade human capsule contracture tissue ex-vivo. The remaining collagen subtype after degradation was type 4 only. 0.3 mg/ml of collagenase was most effective in reducing capsule thickness when compared with higher concentrations. Of note, effectiveness was inversely related to capsule density, such that there was less reduction in thickness with higher capsule densities and vice versa. Furthermore, the application of 0.3mg/ml collagenase did not lead to thinning or perforation of full thickness skin grafts. Adjustment of collagenase dose will depend on thickness and density of the contracted capsule. A concentration of 0.3mg/ml seems to be safe and effective in an ex-vivo setting. The remaining collagen subtype 4 is suitable to serve as a neo-capsule/acellular tissue matrix. Collagenase treatment for capsular contracture may soon become a clinical reality.

  18. Preparation of a Three-Dimensional Full Thickness Skin Equivalent.

    PubMed

    Reuter, Christian; Walles, Heike; Groeber, Florian

    2017-01-01

    In vitro test systems are a promising alternative to animal models. Due to the use of human cells in a three-dimensional arrangement that allows cell-cell or cell-matrix interactions these models may be more predictive for the human situation compared to animal models or two-dimensional cell culture systems. Especially for dermatological research, skin models such as epidermal or full-thickness skin equivalents (FTSE) are used for different applications. Although epidermal models provide highly standardized conditions for risk assessment, FTSE facilitate a cellular crosstalk between the dermal and epidermal layer and thus can be used as more complex models for the investigation of processes such as wound healing, skin development, or infectious diseases. In this chapter, we describe the generation and culture of an FTSE, based on a collagen type I matrix and provide troubleshooting tips for commonly encountered technical problems.

  19. Penetration of Chlorhexidine into Human Skin ▿

    PubMed Central

    Karpanen, T. J.; Worthington, T.; Conway, B. R.; Hilton, A. C.; Elliott, T. S. J.; Lambert, P. A.

    2008-01-01

    This study evaluated a model of skin permeation to determine the depth of delivery of chlorhexidine into full-thickness excised human skin following topical application of 2% (wt/vol) aqueous chlorhexidine digluconate. Skin permeation studies were performed on full-thickness human skin using Franz diffusion cells with exposure to chlorhexidine for 2 min, 30 min, and 24 h. The concentration of chlorhexidine extracted from skin sections was determined to a depth of 1,500 μm following serial sectioning of the skin using a microtome and analysis by high-performance liquid chromatography. Poor penetration of chlorhexidine into skin following 2-min and 30-min exposures to chlorhexidine was observed (0.157 ± 0.047 and 0.077 ± 0.015 μg/mg tissue within the top 100 μm), and levels of chlorhexidine were minimal at deeper skin depths (less than 0.002 μg/mg tissue below 300 μm). After 24 h of exposure, there was more chlorhexidine within the upper 100-μm sections (7.88 ± 1.37 μg/mg tissue); however, the levels remained low (less than 1 μg/mg tissue) at depths below 300 μm. There was no detectable penetration through the full-thickness skin. The model presented in this study can be used to assess the permeation of antiseptic agents through various layers of skin in vitro. Aqueous chlorhexidine demonstrated poor permeation into the deeper layers of the skin, which may restrict the efficacy of skin antisepsis with this agent. This study lays the foundation for further research in adopting alternative strategies for enhanced skin antisepsis in clinical practice. PMID:18676882

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, Adrienne T.; Hayden, Patrick J.; Casillas, Robert P.

    Sulfur mustard is a potent vesicant that induces inflammation, edema and blistering following dermal exposure. To assess molecular mechanisms mediating these responses, we analyzed the effects of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide, on EpiDerm-FT{sup TM}, a commercially available full-thickness human skin equivalent. CEES (100-1000 {mu}M) caused a concentration-dependent increase in pyknotic nuclei and vacuolization in basal keratinocytes; at high concentrations (300-1000 {mu}M), CEES also disrupted keratin filament architecture in the stratum corneum. This was associated with time-dependent increases in expression of proliferating cell nuclear antigen, a marker of cell proliferation, and poly(ADP-ribose) polymerase (PARP) and phosphorylated histonemore » H2AX, markers of DNA damage. Concentration- and time-dependent increases in mRNA and protein expression of eicosanoid biosynthetic enzymes including COX-2, 5-lipoxygenase, microsomal PGE{sub 2} synthases, leukotriene (LT) A{sub 4} hydrolase and LTC{sub 4} synthase were observed in CEES-treated skin equivalents, as well as in antioxidant enzymes, glutathione S-transferases A1-2 (GSTA1-2), GSTA3 and GSTA4. These data demonstrate that CEES induces rapid cellular damage, cytotoxicity and inflammation in full-thickness skin equivalents. These effects are similar to human responses to vesicants in vivo and suggest that the full thickness skin equivalent is a useful in vitro model to characterize the biological effects of mustards and to develop potential therapeutics.« less

  1. Interactions of donor sources and media influence the histo-morphological quality of full-thickness skin models.

    PubMed

    Lange, Julia; Weil, Frederik; Riegler, Christoph; Groeber, Florian; Rebhan, Silke; Kurdyn, Szymon; Alb, Miriam; Kneitz, Hermann; Gelbrich, Götz; Walles, Heike; Mielke, Stephan

    2016-10-01

    Human artificial skin models are increasingly employed as non-animal test platforms for research and medical purposes. However, the overall histopathological quality of such models may vary significantly. Therefore, the effects of manufacturing protocols and donor sources on the quality of skin models built-up from fibroblasts and keratinocytes derived from juvenile foreskins is studied. Histo-morphological parameters such as epidermal thickness, number of epidermal cell layers, dermal thickness, dermo-epidermal adhesion and absence of cellular nuclei in the corneal layer are obtained and scored accordingly. In total, 144 full-thickness skin models derived from 16 different donors, built-up in triplicates using three different culture conditions were successfully generated. In univariate analysis both media and donor age affected the quality of skin models significantly. Both parameters remained statistically significant in multivariate analyses. Performing general linear model analyses we could show that individual medium-donor-interactions influence the quality. These observations suggest that the optimal choice of media may differ from donor to donor and coincides with findings where significant inter-individual variations of growth rates in keratinocytes and fibroblasts have been described. Thus, the consideration of individual medium-donor-interactions may improve the overall quality of human organ models thereby forming a reproducible test platform for sophisticated clinical research. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Suppression of α Smooth Muscle Actin Accumulation by Bovine Fetal Dermal Collagen Matrix in Full Thickness Skin Wounds

    PubMed Central

    Lineaweaver, William; Bush, Katie; James, Kenneth

    2015-01-01

    Abstract The suppression of elements associated with wound contracture and unfavorable scarring is a potentially important strategy in clinical wound management. In this study, the presence of α smooth muscle actin (αSMA), a protein involved in wound contraction, was analyzed in a series of wounds in which bovine fetal collagen (BFC) acellular dermal matrix (PriMatrix) was used in staged split thickness skin graft procedures. The results obtained through histological and quantitative image analyses of incidental biopsies from these wounds demonstrated a suppression of αSMA in the wound regions occupied by assimilated BFC relative to increased levels of αSMA found in other areas of the wound. The αSMA levels found in assimilated BFC were similar to αSMA levels in uninjured human dermis. These findings suggest a mechanism by which application of BFC could decrease contraction of full thickness skin wounds. PMID:25695450

  3. Suppression of α Smooth Muscle Actin Accumulation by Bovine Fetal Dermal Collagen Matrix in Full Thickness Skin Wounds.

    PubMed

    Lineaweaver, William; Bush, Katie; James, Kenneth

    2015-06-01

    The suppression of elements associated with wound contracture and unfavorable scarring is a potentially important strategy in clinical wound management. In this study, the presence of α smooth muscle actin (αSMA), a protein involved in wound contraction, was analyzed in a series of wounds in which bovine fetal collagen (BFC) acellular dermal matrix (PriMatrix) was used in staged split thickness skin graft procedures. The results obtained through histological and quantitative image analyses of incidental biopsies from these wounds demonstrated a suppression of αSMA in the wound regions occupied by assimilated BFC relative to increased levels of αSMA found in other areas of the wound. The αSMA levels found in assimilated BFC were similar to αSMA levels in uninjured human dermis. These findings suggest a mechanism by which application of BFC could decrease contraction of full thickness skin wounds.

  4. Full-thickness tears of the supraspinatus tendon: A three-dimensional finite element analysis.

    PubMed

    Quental, C; Folgado, J; Monteiro, J; Sarmento, M

    2016-12-08

    Knowledge regarding the likelihood of propagation of supraspinatus tears is important to allow an early identification of patients for whom a conservative treatment is more likely to fail, and consequently, to improve their clinical outcome. The aim of this study was to investigate the potential for propagation of posterior, central, and anterior full-thickness tears of different sizes using the finite element method. A three-dimensional finite element model of the supraspinatus tendon was generated from the Visible Human Project data. The mechanical behaviour of the tendon was fitted from experimental data using a transversely isotropic hyperelastic constitutive model. The full-thickness tears were simulated at the supraspinatus tendon insertion by decreasing the interface area. Tear sizes from 10% to 90%, in 10% increments, of the anteroposterior length of the supraspinatus footprint were considered in the posterior, central, and anterior regions of the tendon. For each tear, three finite element analyses were performed for a supraspinatus force of 100N, 200N, and 400N. Considering a correlation between tendon strain and the risk of tear propagation, the simulated tears were compared qualitatively and quantitatively by evaluating the volume of tendon for which a maximum strain criterion was not satisfied. The finite element analyses showed a significant impact of tear size and location not only on the magnitude, but also on the patterns of the maximum principal strains. The mechanical outcome of the anterior full-thickness tears was consistently, and significantly, more severe than that of the central or posterior full-thickness tears, which suggests that the anterior tears are at greater risk of propagating than the central or posterior tears. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. In Vivo Assessment of Printed Microvasculature in a Bilayer Skin Graft to Treat Full-Thickness Wounds

    PubMed Central

    Yanez, Maria; Rincon, Julio; Dones, Aracely; De Maria, Carmelo; Gonzales, Raoul

    2015-01-01

    Chronic wounds such as diabetic foot ulcers and venous leg ulcers are common problems in people suffering from type 2 diabetes. These can cause pain, and nerve damage, eventually leading to foot or leg amputation. These types of wounds are very difficult to treat and sometimes take months or even years to heal because of many possible complications during the process. Allogeneic skin grafting has been used to improve wound healing, but the majority of grafts do not survive several days after being implanted. We have been studying the behavior of fibroblasts and keratinocytes in engineered capillary-like endothelial networks. A dermo-epidermal graft has been implanted in an athymic nude mouse model to assess the integration with the host tissue as well as the wound healing process. To build these networks into a skin graft, a modified inkjet printer was used, which allowed the deposit of human microvascular endothelial cells. Neonatal human dermal fibroblast cells and neonatal human epidermal keratinocytes were manually mixed in the collagen matrix while endothelial cells printed. A full-thickness wound was created at the top of the back of athymic nude mice and the area was covered by the bilayered graft. Mice of the different groups were followed until completion of the specified experimental time line, at which time the animals were humanely euthanized and tissue samples were collected. Wound contraction improved by up to 10% when compared with the control groups. Histological analysis showed the neoskin having similar appearance to the normal skin. Both layers, dermis and epidermis, were present with thicknesses resembling normal skin. Immunohistochemistry analysis showed favorable results proving survival of the implanted cells, and confocal images showed the human cells' location in the samples that were collocated with the bilayer printed skin graft. PMID:25051339

  6. In vivo assessment of printed microvasculature in a bilayer skin graft to treat full-thickness wounds.

    PubMed

    Yanez, Maria; Rincon, Julio; Dones, Aracely; De Maria, Carmelo; Gonzales, Raoul; Boland, Thomas

    2015-01-01

    Chronic wounds such as diabetic foot ulcers and venous leg ulcers are common problems in people suffering from type 2 diabetes. These can cause pain, and nerve damage, eventually leading to foot or leg amputation. These types of wounds are very difficult to treat and sometimes take months or even years to heal because of many possible complications during the process. Allogeneic skin grafting has been used to improve wound healing, but the majority of grafts do not survive several days after being implanted. We have been studying the behavior of fibroblasts and keratinocytes in engineered capillary-like endothelial networks. A dermo-epidermal graft has been implanted in an athymic nude mouse model to assess the integration with the host tissue as well as the wound healing process. To build these networks into a skin graft, a modified inkjet printer was used, which allowed the deposit of human microvascular endothelial cells. Neonatal human dermal fibroblast cells and neonatal human epidermal keratinocytes were manually mixed in the collagen matrix while endothelial cells printed. A full-thickness wound was created at the top of the back of athymic nude mice and the area was covered by the bilayered graft. Mice of the different groups were followed until completion of the specified experimental time line, at which time the animals were humanely euthanized and tissue samples were collected. Wound contraction improved by up to 10% when compared with the control groups. Histological analysis showed the neoskin having similar appearance to the normal skin. Both layers, dermis and epidermis, were present with thicknesses resembling normal skin. Immunohistochemistry analysis showed favorable results proving survival of the implanted cells, and confocal images showed the human cells' location in the samples that were collocated with the bilayer printed skin graft.

  7. A comparison of scaffold-free and scaffold-based reconstructed human skin models as alternatives to animal use.

    PubMed

    Kinikoglu, Beste

    2017-12-01

    Tissue engineered full-thickness human skin substitutes have various applications in the clinic and in the laboratory, such as in the treatment of burns or deep skin defects, and as reconstructed human skin models in the safety testing of drugs and cosmetics and in the fundamental study of skin biology and pathology. So far, different approaches have been proposed for the generation of reconstructed skin, each with its own advantages and disadvantages. Here, the classic tissue engineering approach, based on cell-seeded polymeric scaffolds, is compared with the less-studied cell self-assembly approach, where the cells are coaxed to synthesise their own extracellular matrix (ECM). The resulting full-thickness human skin substitutes were analysed by means of histological and immunohistochemical analyses. It was found that both the scaffold-free and the scaffold-based skin equivalents successfully mimicked the functionality and morphology of native skin, with complete epidermal differentiation (as determined by the expression of filaggrin), the presence of a continuous basement membrane expressing collagen VII, and new ECM deposition by dermal fibroblasts. On the other hand, the scaffold-free model had a thicker epidermis and a significantly higher number of Ki67-positive proliferative cells, indicating a higher capacity for self-renewal, as compared to the scaffold-based model. 2017 FRAME.

  8. Accelerated wound healing in a diabetic rat model using decellularized dermal matrix and human umbilical cord perivascular cells

    PubMed Central

    Milan, P. Brouki; Lotfibakhshaiesh, N.; Joghataie, M.T.; Ai, J.; Pazouki, A.; Kaplan, D.L.; kargozar, S.; Amini, N.; Hamblin, M.R.; Mozafari, M.; Samadikuchaksaraei, A.

    2016-01-01

    There is an unmet clinical need for novel wound healing strategies to treat full thickness skin defects, especially in diabetic patients. We hypothesized that a scaffold could perform dual roles of a biomechanical support and a favorable biochemical environment for stem cells. Human umbilical cord perivascular cells (HUCPVCs) have been recently reported as a type of mesenchymal stem cell that can accelerate early wound healing in skin defects. However, there are only a limited number of studies that have incorporated these cells into natural scaffolds for dermal tissue engineering. The aim of the present study was to promote angiogenesis and accelerate wound healing by using HUCPVCs and decellularized dermal matrix (DDM) in a rat model of diabetic wounds. The DDM scaffolds were prepared from harvested human skin samples and histological, ultrastructural, molecular and mechanical assessments were carried out. In comparison with the control (without any treatment) and DDM alone group, full thickness excisional wounds treated with HUCPVCs-loaded DDM scaffolds demonstrated an accelerated wound closure rate, faster re-epithelization, more granulation tissue formation and decreased collagen deposition. Furthermore, immunofluorescence analysis showed that the VEGFR-2 expression and vascular density in the HUCPVCs-loaded DDM scaffold treated group were also significantly higher than the other groups at 7 days post implantation. Since the rates of angiogenesis, re-epithelization and formation of granulation tissue are directly correlated with full thickness wound healing in patients, the proposed HUCPVCs-loaded DDM scaffolds may fulfil a role neglected by current treatment strategies. This pre-clinical proof-of-concept study warrants further clinical evaluation. Statement of Significance The aim of the present study was to design a novel tissue-engineered system to promote angiogenesis, re-epithelization and granulation of skin tissue using human umbilical cord perivascular stem cells and decellularized dermal matrix natural scaffolds in rat diabetic wound models. The authors of this research article have been working on stem cells and tissue engineering scaffolds for years. According to our knowledge, there is a lack of an efficient system for the treatment of skin defects using tissue engineering strategy. Since the rates of angiogenesis, re-epithelization and granulation tissue are directly correlated with full thickness wound healing, the proposed HUCPVCs-loaded DDM scaffolds perfectly fills the niche neglected by current treatment strategies. This pre-clinical study demonstrates the proof-of-concept that necessitates clinical evaluations. PMID:27591919

  9. Accelerated wound healing in a diabetic rat model using decellularized dermal matrix and human umbilical cord perivascular cells.

    PubMed

    Milan, P Brouki; Lotfibakhshaiesh, N; Joghataie, M T; Ai, J; Pazouki, A; Kaplan, D L; Kargozar, S; Amini, N; Hamblin, M R; Mozafari, M; Samadikuchaksaraei, A

    2016-11-01

    There is an unmet clinical need for novel wound healing strategies to treat full thickness skin defects, especially in diabetic patients. We hypothesized that a scaffold could perform dual roles of a biomechanical support and a favorable biochemical environment for stem cells. Human umbilical cord perivascular cells (HUCPVCs) have been recently reported as a type of mesenchymal stem cell that can accelerate early wound healing in skin defects. However, there are only a limited number of studies that have incorporated these cells into natural scaffolds for dermal tissue engineering. The aim of the present study was to promote angiogenesis and accelerate wound healing by using HUCPVCs and decellularized dermal matrix (DDM) in a rat model of diabetic wounds. The DDM scaffolds were prepared from harvested human skin samples and histological, ultrastructural, molecular and mechanical assessments were carried out. In comparison with the control (without any treatment) and DDM alone group, full thickness excisional wounds treated with HUCPVCs-loaded DDM scaffolds demonstrated an accelerated wound closure rate, faster re-epithelization, more granulation tissue formation and decreased collagen deposition. Furthermore, immunofluorescence analysis showed that the VEGFR-2 expression and vascular density in the HUCPVCs-loaded DDM scaffold treated group were also significantly higher than the other groups at 7days post implantation. Since the rates of angiogenesis, re-epithelization and formation of granulation tissue are directly correlated with full thickness wound healing in patients, the proposed HUCPVCs-loaded DDM scaffolds may fulfil a role neglected by current treatment strategies. This pre-clinical proof-of-concept study warrants further clinical evaluation. The aim of the present study was to design a novel tissue-engineered system to promote angiogenesis, re-epithelization and granulation of skin tissue using human umbilical cord perivascular stem cells and decellularized dermal matrix natural scaffolds in rat diabetic wound models. The authors of this research article have been working on stem cells and tissue engineering scaffolds for years. According to our knowledge, there is a lack of an efficient system for the treatment of skin defects using tissue engineering strategy. Since the rates of angiogenesis, re-epithelization and granulation tissue are directly correlated with full thickness wound healing, the proposed HUCPVCs-loaded DDM scaffolds perfectly fills the niche neglected by current treatment strategies. This pre-clinical study demonstrates the proof-of-concept that necessitates clinical evaluations. Copyright © 2016. Published by Elsevier Ltd.

  10. Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel

    2008-04-01

    The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.

  11. Effect of skin graft thickness on scar development in a porcine burn model.

    PubMed

    DeBruler, Danielle M; Blackstone, Britani N; McFarland, Kevin L; Baumann, Molly E; Supp, Dorothy M; Bailey, J Kevin; Powell, Heather M

    2018-06-01

    Animal models provide a way to investigate scar therapies in a controlled environment. It is necessary to produce uniform, reproducible scars with high anatomic and biologic similarity to human scars to better evaluate the efficacy of treatment strategies and to develop new treatments. In this study, scar development and maturation were assessed in a porcine full-thickness burn model with immediate excision and split-thickness autograft coverage. Red Duroc pigs were treated with split-thickness autografts of varying thickness: 0.026in. ("thin") or 0.058in. ("thick"). Additionally, the thin skin grafts were meshed and expanded at 1:1.5 or 1:4 to evaluate the role of skin expansion in scar formation. Overall, the burn-excise-autograft model resulted in thick, raised scars. Treatment with thick split-thickness skin grafts resulted in less contraction and reduced scarring as well as improved biomechanics. Thin skin autograft expansion at a 1:4 ratio tended to result in scars that contracted more with increased scar height compared to the 1:1.5 expansion ratio. All treatment groups showed Matrix Metalloproteinase 2 (MMP2) and Transforming Growth Factor β1 (TGF-β1) expression that increased over time and peaked 4 weeks after grafting. Burns treated with thick split-thickness grafts showed decreased expression of pro-inflammatory genes 1 week after grafting, including insulin-like growth factor 1 (IGF-1) and TGF-β1, compared to wounds treated with thin split-thickness grafts. Overall, the burn-excise-autograft model using split-thickness autograft meshed and expanded to 1:1.5 or 1:4, resulted in thick, raised scars similar in appearance and structure to human hypertrophic scars. This model can be used in future studies to study burn treatment outcomes and new therapies. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  12. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    PubMed

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P < 0.001). Logistic regression revealed that having a full-thickness tear was the most reliable risk factor for tear progression (P < 0.001). This study found that 28/34 (82.4%) of symptomatic full-thickness rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be monitored more carefully for progression than partial-thickness tears. IV.

  13. Hydroxyapatite paste Ostim, without elevation of full-thickness flaps, improves alveolar healing stimulating BMP- and VEGF-mediated signal pathways: an experimental study in humans.

    PubMed

    Canuto, R A; Pol, R; Martinasso, G; Muzio, G; Gallesio, G; Mozzati, M

    2013-08-01

    Tooth extraction is considered as the starting point of jaw atrophy via osteoclast activity stimulation. The maintenance of dental alveolar bone depends on surgery procedure and use of materials to maintain prior space favoring bone regeneration. Among substitutes used in dentistry to fill bone defects, Ostim-Pastes (Ostim) is a nanocrystalline paste tested for treatment of severe clinical conditions. This research first investigated the effect of Ostim on alveolar healing, comparing in the same healthy subjects, an Ostim-filled socket with a not-filled one. Moreover, it also proposed a new surgical protocol for the post-extractive socket treatment using the graft materials without elevation of full-thickness flaps. Fourteen patients were enrolled to bilateral maxillary or mandibular extraction that was performed without elevation of full-thickness flaps. In each patient, one socket was filled using Ostim, and the other one was allowed to undergo natural healing. No suture was carried out. Clinical and biologic parameters were screened at 1, 7, and 14 days. Obtained results evidenced that nanocrystalline hydroxyapatite supports bone regeneration, increasing the synthesis of pro-osteogenic factors as bone morphogenetics protein (BMP)-4, BMP-7, alkaline phosphatase, and osteocalcin. Moreover, filling post-extractive socket with nanocrystalline hydroxyapatite paste leads to a complete epithelialization already at 7 days after extraction, despite the fact that the teeth were extracted without elevation of full-thickness flaps . The improved epithelialization is mediated by increased vascular endothelial growth factor (VEGF) expression. No significant change was observed in inflammatory parameters, with exception of an early and transient IL-1β induction, that could trigger and improve alveolar healing. Clinical and biomolecular observations of this explorative study evidenced that nanocrystalline hydroxyapatite improves alveolar socket healing, increasing angiogenesis, epithelialization, and osteogenesis, also in absence of elevation of full-thickness flaps. © 2011 John Wiley & Sons A/S.

  14. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity.

    PubMed

    Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong

    2015-03-01

    The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade showed a 7.64-times higher failure rate (95% CI, 1.43-36.04) than did those with a lower tendinosis grade (P = .013). All functional outcome scores improved after surgery (all P < .001); however, there was no difference between groups. The high-grade partial-thickness rotator cuff tears showed more severe tendinosis compared with the small full-thickness tears in this study. Contrary to previous impressions that tear size or fatty infiltration is the factor that most influences healing, tendinosis severity assessed by preoperative MRI was the only factor associated with failure to heal, given the numbers available for analysis, in patients with partial-thickness and small full-thickness rotator cuff tears. Surgeons should pay more attention to tendon quality during repair surgery or rehabilitation in smaller rotator cuff tears, especially in high-grade partial-thickness tears with severe tendinosis. © 2014 The Author(s).

  15. Prenatal factors associated with the neonatal line thickness in human deciduous incisors.

    PubMed

    Kurek, M; Żądzińska, E; Sitek, A; Borowska-Strugińska, B; Rosset, I; Lorkiewicz, W

    2015-06-01

    The neonatal line (NNL) is used to distinguish developmental events observed in enamel which occurred before and after birth. However, there are few studies reporting relationship between the characteristics of the NNL and factors affecting prenatal conditions. The aim of the study was to determine prenatal factors that may influence the NNL thickness in human deciduous teeth. The material consisted of longitudinal ground sections of 60 modern human deciduous incisors obtained from full-term healthy children with reported birth histories and prenatal factors. All teeth were sectioned in the labio-lingual plane using diamond blade (Buechler IsoMet 1000). Final specimens were observed using scanning electron microscopy at magnifications 320×. For each tooth, linear measurements of the NNL thickness were taken on its labial surface at the three levels from the cemento-enamel junction. The difference in the neonatal line thickness between tooth types and between males and females was statistically significant. A multiple regression analyses confirmed influence of two variables on the NNL thickness standardised on tooth type and the children's sex (z-score values). These variables are the taking of an antispasmodic medicine by the mother during pregnancy and the season of the child's birth. These two variables together explain nearly 17% of the variability of the NNL. Children of mothers taking a spasmolytic medicine during pregnancy were characterised by a thinner NNL compared with children whose mothers did not take such medication. Children born in summer and spring had a thinner NNL than children born in winter. These results indicate that the prenatal environment significantly contributes to the thickness of the NNL influencing the pace of reaching the post-delivery homeostasis by the newborn's organism. Copyright © 2014 Elsevier GmbH. All rights reserved.

  16. Human Tau Isoforms Assemble into Ribbon-like Fibrils That Display Polymorphic Structure and Stability*

    PubMed Central

    Wegmann, Susanne; Jung, Yu Jin; Chinnathambi, Subashchandrabose; Mandelkow, Eva-Maria; Mandelkow, Eckhard; Muller, Daniel J.

    2010-01-01

    Fibrous aggregates of Tau protein are characteristic features of Alzheimer disease. We applied high resolution atomic force and EM microscopy to study fibrils assembled from different human Tau isoforms and domains. All fibrils reveal structural polymorphism; the “thin twisted” and “thin smooth” fibrils resemble flat ribbons (cross-section ∼10 × 15 nm) with diverse twist periodicities. “Thick fibrils” show periodicities of ∼65–70 nm and thicknesses of ∼9–18 nm such as routinely reported for “paired helical filaments” but structurally resemble heavily twisted ribbons. Therefore, thin and thick fibrils assembled from different human Tau isoforms challenge current structural models of paired helical filaments. Furthermore, all Tau fibrils reveal axial subperiodicities of ∼17–19 nm and, upon exposure to mechanical stress or hydrophobic surfaces, disassemble into uniform fragments that remain connected by thin thread-like structures (∼2 nm). This hydrophobically induced disassembly is inhibited at enhanced electrolyte concentrations, indicating that the fragments resemble structural building blocks and the fibril integrity depends largely on hydrophobic and electrostatic interactions. Because full-length Tau and repeat domain constructs assemble into fibrils of similar thickness, the “fuzzy coat” of Tau protein termini surrounding the fibril axis is nearly invisible for atomic force microscopy and EM, presumably because of its high flexibility. PMID:20566652

  17. Reconstitution of full-thickness skin by microcolumn grafting.

    PubMed

    Tam, Joshua; Wang, Ying; Vuong, Linh N; Fisher, Jeremy M; Farinelli, William A; Anderson, R Rox

    2017-10-01

    In addition to providing a physical barrier, skin also serves a diverse range of physiological functions through different specialized resident cell types/structures, including melanocytes (pigmentation and protection against ultraviolet radiation), Langerhans cells (adaptive immunity), fibroblasts (maintaining extracellular matrix, paracrine regulation of keratinocytes), sweat glands (thermoregulation) and hair follicles (hair growth, sensation and a stem cell reservoir). Restoration of these functional elements has been a long-standing challenge in efforts to engineer skin tissue, while autologous skin grafting is limited by the scarcity of donor site skin and morbidity caused by skin harvesting. We demonstrate an alternative approach of harvesting and then implanting μm-scale, full-thickness columns of human skin tissue, which can be removed from a donor site with minimal morbidity and no scarring. Fresh human skin microcolumns were used to reconstitute skin in wounds on immunodeficient mice. The restored skin recapitulated many key features of normal human skin tissue, including epidermal architecture, diverse skin cell populations, adnexal structures and sweat production in response to cholinergic stimulation. These promising preclinical results suggest that harvesting and grafting of microcolumns may be useful for reconstituting fully functional skin in human wounds, without donor site morbidity. © 2016 The Authors Journal of Tissue Engineering and Regenerative Medicine Published by John Wiley & Sons Ltd. © 2016 The Authors Journal of Tissue Engineering and Regenerative Medicine Published by John Wiley & Sons Ltd.

  18. Going skin deep: A direct comparison of penetration potential of lipid-based nanovesicles on the isolated perfused human skin flap model.

    PubMed

    Ternullo, Selenia; de Weerd, Louis; Holsæter, Ann Mari; Flaten, Gøril Eide; Škalko-Basnet, Nataša

    2017-12-01

    Phospholipid-based nanocarriers are attractive drug carriers for improved local skin therapy. In the present study, the recently developed isolated perfused human skin flap (IPHSF) model was used to directly compare the skin penetration enhancing potential of the three commonly used nanocarriers, namely conventional liposomes (CLs), deformable liposomes (DLs) and solid lipid nanoparticles (SLNs). Two fluorescent markers, calcein (hydrophilic) or rhodamine (lipophilic), were incorporated individually in the three nanosystems. The nanocarrier size ranged between 200 and 300nm; the surface charge and entrapment efficiency for both markers were dependent on the lipid composition and the employed surfactant. Both carrier-associated markers could not penetrate the full thickness human skin, confirming their suitability for dermal drug delivery. CLs exhibited higher retention of both markers on the skin surface compared to DLs and SLNs, indicating a depo formation. DLs and SLNs enabled the deeper penetration of the two markers into the skin layers. In vitro and ex vivo skin penetration studies performed on the cellophane membrane and full thickness pig/human skin, respectively, confirmed the findings. In conclusion, efficient dermal drug delivery can be achieved by optimization of a lipid nanocarrier on the suitable skin-mimicking model to assure system's accumulation in the targeted skin layer. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A novel model of human skin pressure ulcers in mice.

    PubMed

    Maldonado, Andrés A; Cristóbal, Lara; Martín-López, Javier; Mallén, Mar; García-Honduvilla, Natalio; Buján, Julia

    2014-01-01

    Pressure ulcers are a prevalent health problem in today's society. The shortage of suitable animal models limits our understanding and our ability to develop new therapies. This study aims to report on the development of a novel and reproducible human skin pressure ulcer model in mice. Male non-obese, diabetic, severe combined immunodeficiency mice (n = 22) were engrafted with human skin. A full-thickness skin graft was placed onto 4×3 cm wounds created on the dorsal skin of the mice. Two groups with permanent grafts were studied after 60 days. The control group (n = 6) was focused on the process of engraftment. Evaluations were conducted with photographic assessment, histological analysis and fluorescence in situ hybridization (FISH) techniques. The pressure ulcer group (n = 12) was created using a compression device. A pressure of 150 mmHg for 8 h, with a total of three cycles of compression-release was exerted. Evaluations were conducted with photographic assessment and histological analysis. Skin grafts in the control group took successfully, as shown by visual assessment, FISH techniques and histological analysis. Pressure ulcers in the second group showed full-thickness skin loss with damage and necrosis of all the epidermal and dermal layers (ulcer stage III) in all cases. Complete repair occurred after 40 days. An inexpensive, reproducible human skin pressure ulcer model has been developed. This novel model will facilitate the development of new clinically relevant therapeutic strategies that can be tested directly on human skin.

  20. Sulfur Mustard (SM) Lesions in Organ-Cultured Human Skin: Markers of Injury and Inflammatory Mediators

    DTIC Science & Technology

    1990-04-16

    18. SUB3ECT TERMS (oont’d) epidermal injury organ culture •ranuaear vacuoles C-leucine incorpora’tion by full-thickness human akin explants hi stamine ...mast- cell degranulation prostaglandin E2 lysobomal enzymes: acid phosphatase, B-glucuronidase, 0-galactcsidase, lysozyme and lactic dehydrogenase...that histamline (from local mast cells ), and PA and POgk (probably from mast cells and epidermal cells ) are s3e of the early mediators of the inflmma

  1. Accuracy of Currently Used Paper Burn Diagram vs a Three-Dimensional Computerized Model.

    PubMed

    Benjamin, Nicole C; Lee, Jong O; Norbury, William B; Branski, Ludwik K; Wurzer, Paul; Jimenez, Carlos J; Benjamin, Debra A; Herndon, David N

    Burn units have historically used paper diagrams to estimate percent burn; however, unintentional errors can occur. The use of a computer program that incorporates wound mapping from photographs onto a three-dimensional (3D) human diagram could decrease subjectivity in preparing burn diagrams and subsequent calculations of TBSA burned. Analyses were done on 19 burned patients who had an estimated TBSA burned of ≥20%. The patients were admitted to Shriners Hospitals for Children or the University of Texas Medical Branch in Galveston, Texas, from July 2012 to September 2013 for treatment. Digital photographs were collected before the patient's first surgery. Using BurnCase 3D (RISC Software GmbH, Hagenberg, Austria), a burn mapping software, the user traced partial- and full-thickness burns from photographs. The program then superimposed tracings onto a 3D model and calculated percent burned. The results were compared with the Lund and Browder diagrams completed after the first operation. A two-tailed t-test was used to calculate statistical differences. For partial-thickness burns, burn sizes calculated using Lund and Browder diagrams were significantly larger than those calculated using BurnCase 3D (15% difference, P < .01). The opposite was found for full-thickness burns, with burn sizes being smaller when calculated using Lund and Browder diagrams (11% difference, P < .05). In conclusion, substantial differences exist in percent burn estimations derived from BurnCase 3D and paper diagrams. In our studied cohort, paper diagrams were associated with overestimation of partial-thickness burn size and underestimation of full-thickness burn size. Additional studies comparing BurnCase 3D with other commonly used methods are warranted.

  2. Adenoviral Mediated Gene Transfer of IGF-1 Enhances Wound Healing and Induces Angiogenesis

    PubMed Central

    Balaji, S.; LeSaint, M.; Bhattacharya, S. S.; Moles, C.; Dhamija, Y.; Kidd, M.; Le, L.D.; King, A.; Shaaban, A.; Crombleholme, T. M.; Bollyky, P.; Keswani, S. G.

    2014-01-01

    Background Chronic wounds are characterized by a wound healing and neovascularization deficit. Strategies to increase neovascularization can significantly improve chronic wound healing. Insulin like growth factor (IGF-1) is reported to be a keratinocyte mitogen and is believed to induce angiogenesis via a vascular endothelial growth factor (VEGF) dependent pathway. Using a novel ex vivo human dermal wound model and a diabetic impaired wound healing murine model, we hypothesized that adenoviral over expression of IGF-1 (Ad-IGF-1) will enhance wound healing and induce angiogenesis through a VEGF dependent pathway. Methods Ex vivo: 6 mm full thickness punch biopsies were obtained from normal human skin, and 3 mm full thickness wounds were created at the center. Skin explants were maintained at air liquid interface. Db/db murine model: 8 mm full thickness dorsal wounds in diabetic (db/db) mice were created. Treatment groups in both human ex vivo and in vivo db/db wound models include 1×108 PFU of Ad-IGF-1 or Ad-LacZ, and PBS (n=4–5/group). Cytotoxicity (LDH) was quantified at days 3, 5 and 7 for the human ex vivo wound model. Epithelial gap closure (H&E; Trichrome), VEGF expression (ELISA) and capillary density (CD 31+ CAPS/HPF) were analyzed at day 7. Results In the human ex vivo organ culture, the adenoviral vectors did not demonstrate any significant difference in cytotoxicity compared to PBS. Ad-IGF-1 over expression significantly increases basal keratinocyte migration, with no significant effect on epithelial gap closure. There was a significant increase in capillary density in the Ad-IGF-1 wounds. However, there was no effect on VEGF levels in Ad-IGF-1 samples compared to controls. In db/db wounds, Ad-IGF-1 over expression significantly improves epithelial gap closure and granulation tissue with a dense cellular infiltrate compared to controls. Ad-IGF-1 also increases capillary density, again with no significant difference in VEGF levels in the wounds compared to control treatments. Conclusions In two different models, our data demonstrates that adenoviral mediated gene transfer of IGF-1 results in enhanced wound healing and induces angiogenesis via a VEGF-independent pathway. Understanding the underlying mechanisms of IGF-1 effects on angiogenesis may help produce novel therapeutics for chronic wounds or diseases characterized by a deficit in neovascularization. PMID:24725678

  3. Surgical correction of cryptotia combined with an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap.

    PubMed

    Yu, Xiaobo; Yang, Qinghua; Jiang, Haiyue; Pan, Bo; Zhao, Yanyong; Lin, Lin

    2017-11-01

    Cryptotia is a common congenital ear deformity in Asian populations. In cryptotia, a portion of the upper ear is hidden and fixed in a pocket of the skin of the mastoid. Here we describe our method for cryptotia correction by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. We developed a new method for correcting cryptotia by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. Following ear release, the full-thickness skin rotation flap is rotated into the defect, and the donor site is covered with an ultra-delicate split-thickness skin graft raised in continuity with the flap. All patients exhibited satisfactory release of cryptotia. No cases involved partial or total flap necrosis, and post-operative outcomes using this new technique for cryptotia correction have been more than satisfactory. Our method of using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap to correct cryptotia is simple and reliable. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Demonstration of anatomical development of the human macula within the first 5 years of life using handheld OCT.

    PubMed

    Alabduljalil, Talal; Westall, Carol A; Reginald, Arun; Farsiu, Sina; Chiu, Stephanie J; Arshavsky, Alec; Toth, Cynthia A; Lam, Wai-Ching

    2018-06-23

    To demonstrate the anatomical development of the human macula using handheld spectral domain optical coherence tomography (SD-OCT) during the first 5 years of life. This study is a cross-sectional, observational case series. Thirty-five normal eyes of 35 full-term/late preterm infants and children under 5 years of age were included. Handheld SD-OCT was used to image the macula of each eye. The data were analyzed using the Duke OCT Retinal Analysis Program v17 software. Retinal thickness maps were generated for the total retinal thickness (TRT), the inner retinal layers thickness (IRL), and the photoreceptor layer thickness (PRL). Based on the early treatment diabetic retinopathy study macular map, average thickness measurements were taken at 4 circles centered on the fovea (diameter): the foveal center (0.5 mm), sector 1 (S1) (1 mm), sector 2 (S2) (3 mm), sector 3 (S3) (6 mm). The median age at participation was 24 months (range 5-52 months). The TRT increased throughout the first 5 years of life, and this increase was statistically significant at the foveal center and S1 (p = 0.01, p = 0.016, respectively). The IRL did not show any significant change in thickness from birth and throughout the first 5 years of life. The PRL thickness showed thickening in the first 24 months of age at the foveal center and S1 which was statistically significant at S1 (p = 0.066, p = 0.016, respectively). Interestingly, this PRL thickness increase plateaus beyond 24 months of age. The photoreceptors inner segment/outer segment (IS/OS) band was identified as a distinct layer in all our subjects. Our findings conform with the literature that the anatomical development of the macular IRL completes before 5 months of age and hence before the PRL. We also identify 24 months of age as an important developmental milestone for photoreceptors development in the human macula.

  5. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    PubMed

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Updates in biological therapies for knee injuries: full thickness cartilage defect.

    PubMed

    Nicolini, Alexandre Pedro; Carvalho, Rogerio Teixeira; Dragone, Bruno; Lenza, Mario; Cohen, Moises; Ferretti, Mario

    2014-09-01

    Full thickness cartilage defect might occur at different ages, but a focal defect is a major concern in the knee of young athletes. It causes impairment and does not heal by itself. Several techniques were described to treat symptomatic full thickness cartilage defect. Recently, several advances were described on the known techniques of microfracture, osteochondral allograft, cell therapy, and others. This article brings an update of current literature on these well-described techniques for full thickness cartilage defect.

  7. Revision Vaginoplasty: A Comparison of Surgical Outcomes of Laparoscopic Intestinal versus Perineal Full-Thickness Skin Graft Vaginoplasty.

    PubMed

    Van der Sluis, Wouter B; Bouman, Mark-Bram; Buncamper, Marlon E; Mullender, Margriet G; Meijerink, Wilhelmus J

    2016-10-01

    Vaginal (re)construction can greatly improve the quality of life of indicated patients. If primary vaginoplasty fails, multiple surgical approaches exist for revision. The authors compared surgical results of laparoscopic intestinal versus full-thickness skin graft revision vaginoplasty. A retrospective chart review of patients who underwent revision vaginoplasty at the authors' institution was conducted. Patient demographics, surgical characteristics, complications, hospitalization, reoperations, and neovaginal depth for both surgical techniques were recorded and compared. The authors studied a consecutive series of 50 transgender and three biological women who underwent revision vaginoplasty, of which 21 were laparoscopic intestinal and 32 were perineal full-thickness skin graft vaginoplasties, with a median clinical follow-up of 3.2 years (range, 0.5 to 19.7 years). Patient demographics did not differ significantly. There was no mortality. Two intraoperative rectal perforations (10 percent) occurred in the intestinal group versus six (19 percent) in the full-thickness skin graft group. Operative time was shorter for the full-thickness skin graft vaginoplasty group (131 ± 35 minutes versus 191 ± 45 minutes; p < 0.01). Hospitalization length did not differ significantly. Successful vaginal (re)construction was achieved in 19 intestinal (91 percent) and 26 full-thickness skin graft (81 percent) vaginoplasty procedures. A deeper neovagina was achieved with intestinal vaginoplasty (15.9 ± 1.4 cm versus 12.5 ± 2.8 cm; p < 0.01). Both laparoscopic intestinal and full-thickness skin graft vaginoplasty can be used as secondary vaginal reconstruction. Intraoperative and postoperative complications do not differ significantly, but rectal perforation was more prevalent in the full-thickness skin graft vaginoplasty group. Although the operative time of laparoscopic intestinal vaginoplasty is longer, adequate neovaginal depth was more frequently achieved than in secondary perineal full-thickness skin graft vaginoplasty. Therapeutic, III.

  8. Skin corrosion test: a comparison between reconstructed human epidermis and full thickness skin models.

    PubMed

    Catarino, Carolina Motter; do Nascimento Pedrosa, Tatiana; Pennacchi, Paula Comune; de Assis, Silvia Romano; Gimenes, Fabrícia; Consolaro, Márcia Edilaine Lopes; de Moraes Barros, Silvia Berlanga; Maria-Engler, Silvya Stuchi

    2018-04-01

    Currently, there is a strong global trend towards the development of in vitro models to replace the use of animals in safety evaluation tests. Reconstructed Human Epidermis (RHE) models have been employed as an alternative method to animal testing of skin corrosion and irritation potential of chemical compounds. However, the consequences of an absence of the dermal compartment in these models should be considered since the cross-talk between fibroblasts and keratinocytes is fundamental for promoting proper epidermal stratification, homeostasis, inflammatory response and wound healing. In this study, we compare in-house developed models of Reconstructed Human Epidermis (i.e. USP-RHE) and full thickness skin (i.e. USP-FTS) regarding their response when submitted to skin corrosion assays, based on Guideline 431 (OECD). The results show that both models correctly classified the four substances tested (2-phenylethyl bromide, benzylacetone, lactic acid, octanoic acid) as corrosive or non-corrosive. Furthermore, we have demonstrated higher cell viability of the USP-FTS model compared to the USP-RHE model, a sign of its improved barrier function, following the exposure to the substances test on the corrosion assay. This emphasizes the importance of employing in vitro models that are more physiologically relevant and that better mimic the in vivo situation for the toxicological screening of substances. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Development of a Porcine Full-Thickness Burn Hypertrophic Scar Model and Investigation of the Effects of Shikonin on Hypertrophic Scar Remediation

    PubMed Central

    Deng, Xingwang; Chen, Qian; Qiang, Lijuan; Chi, Mingwei; Xie, Nan; Wu, Yinsheng; Yao, Ming; Zhao, Dan; Ma, Jiaxiang; Zhang, Ning; Xie, Yan

    2018-01-01

    Hypertrophic scars formed after burns remain a challenge in clinical practice. Development of effective scar therapies relies on validated animal models that mimic human hypertrophic scars. A consistent porcine full-thickness burn hypertrophic scar model has yet to be developed. We have previously reported that Shikonin induces apoptosis and reduces collagen production in hypertrophic scar fibroblasts in vitro and may therefore hold potential as a novel scar remediation therapy. In this study, we aimed to validate the potential of Shikonin on scar remediation in vivo. A novel porcine hypertrophic scar model was created after full-thickness burn wounds, and the effect of Shikonin on scar remediation was investigated. Clinical scar assessments, histology, and immunohistochemistry were used to evaluate scar appearance, morphology, and protein expression. Eight weeks after scar formation, clinical scar assessment indicated that the score of hypertrophic scars treated with Shikonin was significantly lower than that of the control group. Hypertrophic scars treated with Shikonin appeared flat, pink, and pliable. In addition, histological analysis indicated that hypertrophic scars treated with Shikonin exhibited reduced thickness of the epidermis and dermis, thin and even epithelial layers, reduced numbers of keratinocytes, uniform distribution of fibroblasts, and a parallel and loose arrangement of collagen fibers in the dermis. Moreover, immunohistochemical analysis indicated that Shikonin inhibited the expression of p63, cytokeratin 10, alpha-smooth muscle actin, transforming growth factor-beta 1, and collagen I, which play important roles in hypertrophic scar formation. Based on these results, we conclude that Shikonin has potential as a novel scar therapy. PMID:29922164

  10. Forty-Year Follow-up of Full-Thickness Skin Graft After Thermal Burn Injury to the Volar Hand.

    PubMed

    Weeks, Dexter; Kasdan, Morton L; Wilhelmi, Bradon J

    2016-01-01

    The hands are commonly affected in severe thermal burn injuries. Resulting contractures lead to significant loss of function. Burn contracture release and skin grafting are necessary to restore hand function. We report a case in which surgical reconstruction of a volar hand burn was performed with full-thickness skin grafting. The patient had a 40-year follow-up to assess the function and cosmesis of the repaired hand. We report a case in which a 15-month-old boy presented after receiving third-degree burns to the left volar hand, including the flexural aspects of the index, long, and ring fingers by placing it on a hot kitchen stove burner. The patient subsequently underwent scar contracture release and full-thickness skin grafting. Eleven years after reconstruction, further contractures developed associated with the patient's growth, which were reconstructed with repeat full-thickness skin graft from the inguinal region. No recurrence was witnessed afterward and 40 years after initial injury, the patient maintains full activities of daily living and use of his hand in his occupation. There is debate regarding the superiority of split-thickness versus full-thickness grafts during reconstruction. Our case strengthens the argument for durability of a full-thickness skin graft following thermal burn injury.

  11. Endoscopic full-thickness resection of gastric subepithelial tumors: a single-center series.

    PubMed

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; von Renteln, Daniel; Muehleisen, Helmut; Caca, Karel

    2015-02-01

    Endoscopic full-thickness resection of gastric subepithelial tumors with a full-thickness suturing device has been described as feasible in two small case series. The aim of this study was to evaluate the efficacy, safety, and clinical outcome of this resection technique. After 31 patients underwent endoscopic full-thickness resection, the data were analyzed retrospectively. Before snare resection, 1 to 3 full-thickness sutures were placed underneath each tumor with a device originally designed for endoscopic anti-reflux therapy. All tumors were resected successfully. Bleeding occurred in 12 patients (38.7 %); endoscopic hemostasis could be achieved in all cases. Perforation occurred in 3 patients (9.6 %), and all perforations could be managed endoscopically. Complete resection was histologically confirmed in 28 of 31 patients (90.3 %). Mean follow-up was 213 days (range, 1 - 1737), and no tumor recurrences were observed. Endoscopic full-thickness resection of gastric subepithelial tumors with the suturing technique described above is feasible and effective. After the resection of gastrointestinal stromal tumors (GISTs), we did not observe any recurrences during follow-up, indicating that endoscopic full-thickness resection may be an alternative to surgical resection for selected patients. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Cutaneous wound healing after treatment with plant-derived human recombinant collagen flowable gel.

    PubMed

    Shilo, Shani; Roth, Sigal; Amzel, Tal; Harel-Adar, Tamar; Tamir, Eran; Grynspan, Frida; Shoseyov, Oded

    2013-07-01

    Chronic wounds, particularly diabetic ulcers, represent a main public health concern with significant costs. Ulcers often harbor an additional obstacle in the form of tunneled or undermined wounds, requiring treatments that can reach the entire wound tunnel, because bioengineered grafts are typically available only in a sheet form. While collagen is considered a suitable biodegradable scaffold material, it is usually extracted from animal and human cadaveric sources, and accompanied by potential allergic and infectious risks. The purpose of this study was to test the performance of a flowable gel made of human recombinant type I collagen (rhCollagen) produced in transgenic tobacco plants, indicated for the treatment of acute, chronic, and tunneled wounds. The performance of the rhCollagen flowable gel was tested in an acute full-thickness cutaneous wound-healing rat model and compared to saline treatment and two commercial flowable gel control products made of bovine collagen and cadaver human skin collagen. When compared to the three control groups, the rhCollagen-based gel accelerated wound closure and triggered a significant jumpstart to the healing process, accompanied by enhanced re-epithelialization. In a cutaneous full-thickness wound pig model, the rhCollagen-based flowable gel induced accelerated wound healing compared to a commercial product made of bovine tendon collagen. By day 21 post-treatment, 95% wound closure was observed with the rhCollagen product compared to 68% closure in wounds treated with the reference product. Moreover, rhCollagen treatment induced an early angiogenic response and induced a significantly lower inflammatory response than in the control group. In summary, rhCollagen flowable gel proved to be efficacious in animal wound models and is expected to be capable of reducing the healing time of human wounds.

  13. Cutaneous Wound Healing After Treatment with Plant-Derived Human Recombinant Collagen Flowable Gel

    PubMed Central

    Roth, Sigal; Amzel, Tal; Harel-Adar, Tamar; Tamir, Eran; Grynspan, Frida; Shoseyov, Oded

    2013-01-01

    Chronic wounds, particularly diabetic ulcers, represent a main public health concern with significant costs. Ulcers often harbor an additional obstacle in the form of tunneled or undermined wounds, requiring treatments that can reach the entire wound tunnel, because bioengineered grafts are typically available only in a sheet form. While collagen is considered a suitable biodegradable scaffold material, it is usually extracted from animal and human cadaveric sources, and accompanied by potential allergic and infectious risks. The purpose of this study was to test the performance of a flowable gel made of human recombinant type I collagen (rhCollagen) produced in transgenic tobacco plants, indicated for the treatment of acute, chronic, and tunneled wounds. The performance of the rhCollagen flowable gel was tested in an acute full-thickness cutaneous wound-healing rat model and compared to saline treatment and two commercial flowable gel control products made of bovine collagen and cadaver human skin collagen. When compared to the three control groups, the rhCollagen-based gel accelerated wound closure and triggered a significant jumpstart to the healing process, accompanied by enhanced re-epithelialization. In a cutaneous full-thickness wound pig model, the rhCollagen-based flowable gel induced accelerated wound healing compared to a commercial product made of bovine tendon collagen. By day 21 post-treatment, 95% wound closure was observed with the rhCollagen product compared to 68% closure in wounds treated with the reference product. Moreover, rhCollagen treatment induced an early angiogenic response and induced a significantly lower inflammatory response than in the control group. In summary, rhCollagen flowable gel proved to be efficacious in animal wound models and is expected to be capable of reducing the healing time of human wounds. PMID:23259631

  14. Effect of evaporative surface cooling on thermographic assessment of burn depth

    NASA Technical Reports Server (NTRS)

    Anselmo, V. J.; Zawacki, B. E.

    1977-01-01

    Differences in surface temperature between evaporating and nonevaporating, partial- and full-thickness burn injuries were studied in 20 male, white guinea pigs. Evaporative cooling can disguise the temperature differential of the partial-thickness injury and lead to a false full-thickness diagnosis. A full-thickness burn with blister intact may retain enough heat to result in a false partial-thickness diagnosis. By the fourth postburn day, formation of a dry eschar may allow a surface temperature measurement without the complication of differential evaporation. For earlier use of thermographic information, evaporation effects must be accounted for or eliminated.

  15. SUCCESSFUL CLOSURE OF FULL-THICKNESS MACULAR HOLES SECONDARY TO MACULAR VITELLIFORM LESIONS.

    PubMed

    Galvin, Justin C; Chua, Brian E; Fung, Adrian T

    2017-03-22

    To describe the first reported cases of full-thickness macular holes secondary to vitelliform lesions that were successfully closed with vitrectomy surgery and gas tamponade. Two female patients developed visual loss secondary to bilateral vitelliform lesions and associated full-thickness macular holes. The patients underwent 25-gauge pars plana vitrectomy, internal limiting membrane peeling, and 26% sulfur hexafluoride gas, followed by 3 days of face-down positioning. In both patients, the macular holes remain closed 3 and 25 months postoperatively. Vitrectomy surgery with gas tamponade may successfully close full-thickness macular holes secondary to macular vitelliform lesions.

  16. On the homogeneity and heterogeneity of cortical thickness profiles in Homo sapiens sapiens.

    PubMed

    Koten, Jan Willem; Schüppen, André; Morozova, Maria; Lehofer, Agnes; Koschutnig, Karl; Wood, Guilherme

    2017-12-20

    Cortical thickness has been investigated since the beginning of the 20th century, but we do not know how similar the cortical thickness profiles among humans are. In this study, the local similarity of cortical thickness profiles was investigated using sliding window methods. Here, we show that approximately 5% of the cortical thickness profiles are similarly expressed among humans while 45% of the cortical thickness profiles show a high level of heterogeneity. Therefore, heterogeneity is the rule, not the exception. Cortical thickness profiles of somatosensory homunculi and the anterior insula are consistent among humans, while the cortical thickness profiles of the motor homunculus are more variable. Cortical thickness profiles of homunculi that code for muscle position and skin stimulation are highly similar among humans despite large differences in sex, education, and age. This finding suggests that the structure of these cortices remains well preserved over a lifetime. Our observations possibly relativize opinions on cortical plasticity.

  17. Models of wound healing: an emphasis on clinical studies.

    PubMed

    Wilhelm, K-P; Wilhelm, D; Bielfeldt, S

    2017-02-01

    The healing of wounds has always provided challenges for the medical community whether chronic or acute. Understanding the processes which enable wounds to heal is primarily carried out by the use of models, in vitro, animal and human. It is generally accepted that the use of human models offers the best opportunity to understand the factors that influence wound healing as well as to evaluate efficacy of treatments applied to wounds. The objective of this article is to provide an overview of the different methodologies that are currently used to experimentally induce wounds of various depths in human volunteers and examines the information that may be gained from them. There is a number of human volunteer healing models available varying in their invasiveness to reflect the different possible depth levels of wounds. Currently available wound healing models include sequential tape stripping, suction blister, abrasion, laser, dermatome, and biopsy techniques. The various techniques can be utilized to induce wounds of variable depth, from removing solely the stratum corneum barrier, the epidermis to even split-thickness or full thickness wounds. Depending on the study objective, a number of models exist to study wound healing in humans. These models provide efficient and reliable results to evaluate treatment modalities. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Effect of gender and sports on the risk of full-thickness articular cartilage lesions in anterior cruciate ligament-injured knees: a nationwide cohort study from Sweden and Norway of 15 783 patients.

    PubMed

    Røtterud, Jan Harald; Sivertsen, Einar A; Forssblad, Magnus; Engebretsen, Lars; Årøen, Asbjørn

    2011-07-01

    The presence of an articular cartilage lesion in anterior cruciate ligament-injured knees is considered a predictor of osteoarthritis. This study was undertaken to evaluate risk factors for full-thickness articular cartilage lesions in anterior cruciate ligament-injured knees, in particular the role of gender and the sport causing the initial injury. Cohort study (prognosis); Level of evidence, 2. Primary unilateral anterior cruciate ligament reconstructions prospectively registered in the Swedish and the Norwegian National Knee Ligament Registry during 2005 through 2008 were included (N = 15 783). Logistic regression analyses were used to evaluate risk factors for cartilage lesions. A total of 1012 patients (6.4%) had full-thickness cartilage lesions. The median time from injury to surgery was 9 months (range, 0 days-521 months). Male patients had an increased odds of full-thickness cartilage lesions compared with females (odds ratio = 1.22; 95% confidence interval, 1.04-1.42). In males, team handball had an increase in the odds of full-thickness cartilage lesions compared with soccer (odds ratio = 2.36; 95% confidence interval, 1.33-4.19). Among female patients, no sport investigated showed a significant decrease or increase in the odds of full-thickness cartilage lesions. The odds of a full-thickness cartilage lesion increased by 1.006 (95% confidence interval, 1.005-1.008) for each month elapsed from time of injury until anterior cruciate ligament reconstruction when all patients were considered, while time from injury to surgery did not affect the odds significantly in those patients reconstructed within 1 year of injury (odds ratio = 0.98; 95% confidence interval, 0.95-1.02). Previous surgery increased the odds of having a full-thickness cartilage lesion (odds ratio = 1.40; 95% confidence interval, 1.21-1.63). One year of increasing patient age also increased the odds (odds ratio = 1.05; 95% confidence interval, 1.05-1.06). Male gender is associated with an increased risk of full-thickness articular cartilage lesions in anterior cruciate ligament-injured knees. Male team handball players had an increased risk of full-thickness lesions. No other sports investigated were found to have significant effect on the risk in either gender. Furthermore, age, previous surgery, and time from injury to surgery exceeding 12 months are risk factors for full-thickness cartilage lesions.

  19. Vitrectomy for full-thickness macular hole in adult-onset Coats’ disease

    PubMed Central

    Kumar, Vinod; Kumar, Pradeep; Garg, Gaurav; Damodaran, Saurabh

    2017-01-01

    The occurrence of full thickness macular hole in Coats’ disease is extremely rare. The purpose of this case report is to report pars plana vitrectomy for the treatment of full thickness macular hole in a patient with adult onset Coats disease. A young male presented with decreased vision in his right eye because of full thickness macular hole. The macular hole was found to be associated with adult onset Coats’ disease that was evident on ultra-wide field imaging. The patient underwent laser photocoagulation to the vascular telangiectasia followed by pars plana vitrectomy, large internal limiting membrane peeling and gas tamponade. This resulted in regression of exudation, closure of macular hole and improvement in vision. Coats disease of adult onset can present with decreased vision because of full thickness macular hole. Vitrectomy with internal limiting membrane peeling can result in excellent visual outcome. PMID:29133668

  20. Differential effects of Losartan and Atorvastatin in partial and full thickness burn wounds

    PubMed Central

    Akershoek, Johanneke J.; Brouwer, Katrien M.; Vlig, Marcel; Boekema, Bouke K. H. L.; Beelen, Rob H. J.; Middelkoop, Esther

    2017-01-01

    Healing of burn wounds is often associated with scar formation due to excessive inflammation and delayed wound closure. To date, no effective treatment is available to prevent the fibrotic process. The Renin Angiotensin System (RAS) was shown to be involved in fibrosis in various organs. Statins (e.g. Atorvastatin), Angiotensin receptor antagonists (e.g. Losartan) and the combination of these drugs are able to reduce the local RAS activation, and reduced fibrosis in other organs. We investigated whether inhibition of the RAS could improve healing of burn wounds by treatment with Atorvastatin, Losartan or the combination of both drugs. Therefore, full and partial thickness burn wounds were inflicted on both flanks of Yorkshire pigs. Oral administration of Atorvastatin, Losartan or the combination was started at post-burn day 1 and continued for 28 days. Full thickness wounds were excised and transplanted with an autologous meshed split-thickness skin graft at post-burn day 14. Partial thickness wounds received conservative treatment. Atorvastatin treatment resulted in enhanced graft take and wound closure of the full thickness wounds, faster resolution of neutrophils compared to all treatments and reduced alpha-smooth muscle actin positive cells compared to control treatment. Treatment with Losartan and to a lesser extent the combination therapy resulted in diminished graft take, increased wound contraction and poorer scar outcome. In contrast, Losartan treatment in partial thickness wounds decreased the alpha-smooth muscle actin+ fibroblasts and contraction. In conclusion, we showed differential effects of Losartan and Atorvastatin in full and partial thickness wounds. The extensive graft loss seen in Losartan treated wounds is most likely responsible for the poor clinical outcome of these full thickness burn wounds. Therefore, Losartan treatment should not be started before transplantation in order to prevent graft loss. Atorvastatin seems to accelerate the healing process in full thickness wounds possibly by dampening the pro-inflammatory response. PMID:28614412

  1. Differential effects of Losartan and Atorvastatin in partial and full thickness burn wounds.

    PubMed

    Akershoek, Johanneke J; Brouwer, Katrien M; Vlig, Marcel; Boekema, Bouke K H L; Beelen, Rob H J; Middelkoop, Esther; Ulrich, Magda M W

    2017-01-01

    Healing of burn wounds is often associated with scar formation due to excessive inflammation and delayed wound closure. To date, no effective treatment is available to prevent the fibrotic process. The Renin Angiotensin System (RAS) was shown to be involved in fibrosis in various organs. Statins (e.g. Atorvastatin), Angiotensin receptor antagonists (e.g. Losartan) and the combination of these drugs are able to reduce the local RAS activation, and reduced fibrosis in other organs. We investigated whether inhibition of the RAS could improve healing of burn wounds by treatment with Atorvastatin, Losartan or the combination of both drugs. Therefore, full and partial thickness burn wounds were inflicted on both flanks of Yorkshire pigs. Oral administration of Atorvastatin, Losartan or the combination was started at post-burn day 1 and continued for 28 days. Full thickness wounds were excised and transplanted with an autologous meshed split-thickness skin graft at post-burn day 14. Partial thickness wounds received conservative treatment. Atorvastatin treatment resulted in enhanced graft take and wound closure of the full thickness wounds, faster resolution of neutrophils compared to all treatments and reduced alpha-smooth muscle actin positive cells compared to control treatment. Treatment with Losartan and to a lesser extent the combination therapy resulted in diminished graft take, increased wound contraction and poorer scar outcome. In contrast, Losartan treatment in partial thickness wounds decreased the alpha-smooth muscle actin+ fibroblasts and contraction. In conclusion, we showed differential effects of Losartan and Atorvastatin in full and partial thickness wounds. The extensive graft loss seen in Losartan treated wounds is most likely responsible for the poor clinical outcome of these full thickness burn wounds. Therefore, Losartan treatment should not be started before transplantation in order to prevent graft loss. Atorvastatin seems to accelerate the healing process in full thickness wounds possibly by dampening the pro-inflammatory response.

  2. Assessing the Impact of Mechanical Damage on Full-Thickness Porcine and Human Skin Using an In Vitro Approach

    PubMed Central

    Builles, Nicolas; Frouin, Éric; Scott, Dan; Ramos, Jeanne; Marti-Mestres, Gilberte

    2015-01-01

    For most xenobiotics, the rates of percutaneous absorption are limited by diffusion through the horny layer of skin. However, percutaneous absorption of chemicals may seriously increase when the skin is damaged. The aim of this work was to develop an in vitro representative model of mechanically damaged skins. The epidermal barrier was examined following exposure to a razor, a rotating brush, and a microneedle system in comparison to tape-stripping which acted as a reference. Excised full-thickness skins were mounted on a diffusion chamber in order to evaluate the effect of injuries and to mimic physiological conditions. The transepidermal water loss (TEWL) was greatly increased when the barrier function was compromised. Measurements were made for all the damaged biopsies and observed histologically by microscopy. On human and porcine skins, the tape-stripping application (0 to 40 times) showed a proportional increase in TEWL which highlights the destruction of the stratum corneum. Similar results were obtained for all cosmetic instruments. This is reflected in our study by the nonsignificant difference of the mean TEWL scores between 30 strips and mechanical damage. For a specific appreciation, damaged skins were then selected to qualitatively evaluate the absorption of a chlorogenic acid solution using fluorescence microscopy. PMID:26247021

  3. Validation of the 3D Skin Comet assay using full thickness skin models: Transferability and reproducibility.

    PubMed

    Reisinger, Kerstin; Blatz, Veronika; Brinkmann, Joep; Downs, Thomas R; Fischer, Anja; Henkler, Frank; Hoffmann, Sebastian; Krul, Cyrille; Liebsch, Manfred; Luch, Andreas; Pirow, Ralph; Reus, Astrid A; Schulz, Markus; Pfuhler, Stefan

    2018-03-01

    Recently revised OECD Testing Guidelines highlight the importance of considering the first site-of-contact when investigating the genotoxic hazard. Thus far, only in vivo approaches are available to address the dermal route of exposure. The 3D Skin Comet and Reconstructed Skin Micronucleus (RSMN) assays intend to close this gap in the in vitro genotoxicity toolbox by investigating DNA damage after topical application. This represents the most relevant route of exposure for a variety of compounds found in household products, cosmetics, and industrial chemicals. The comet assay methodology is able to detect both chromosomal damage and DNA lesions that may give rise to gene mutations, thereby complementing the RSMN which detects only chromosomal damage. Here, the comet assay was adapted to two reconstructed full thickness human skin models: the EpiDerm™- and Phenion ® Full-Thickness Skin Models. First, tissue-specific protocols for the isolation of single cells and the general comet assay were transferred to European and US-American laboratories. After establishment of the assay, the protocol was then further optimized with appropriate cytotoxicity measurements and the use of aphidicolin, a DNA repair inhibitor, to improve the assay's sensitivity. In the first phase of an ongoing validation study eight chemicals were tested in three laboratories each using the Phenion ® Full-Thickness Skin Model, informing several validation modules. Ultimately, the 3D Skin Comet assay demonstrated a high predictive capacity and good intra- and inter-laboratory reproducibility with four laboratories reaching a 100% predictivity and the fifth yielding 70%. The data are intended to demonstrate the use of the 3D Skin Comet assay as a new in vitro tool for following up on positive findings from the standard in vitro genotoxicity test battery for dermally applied chemicals, ultimately helping to drive the regulatory acceptance of the assay. To expand the database, the validation will continue by testing an additional 22 chemicals. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Spontaneous cell sorting of fibroblasts and keratinocytes creates an organotypic human skin equivalent.

    PubMed

    Wang, C K; Nelson, C F; Brinkman, A M; Miller, A C; Hoeffler, W K

    2000-04-01

    We show that an inherent ability of two distinct cell types, keratinocytes and fibroblasts, can be relied upon to accurately reconstitute full-thickness human skin including the dermal-epidermal junction by a cell-sorting mechanism. A cell slurry containing both cell types added to silicone chambers implanted on the backs of severe combined immunodeficient mice sorts out to reconstitute a clearly defined dermis and stratified epidermis within 2 wk, forming a cell-sorted skin equivalent. Immunostaining of the cell-sorted skin equivalent with human cell markers showed patterns similar to those of normal full-thickness skin. We compared the cell-sorted skin equivalent model with a composite skin model also made on severe combined immunodeficient mice. The composite grafts were constructed from partially differentiated keratinocyte sheets placed on top of a dermal equivalent constructed of devitalized dermis. Electron microscopy revealed that both models formed ample numbers of normal appearing hemidesmosomes. The cell-sorted skin equivalent model, however, had greater numbers of keratin intermediate filaments within the basal keratinocytes that connected to hemidesmosomes, and on the dermal side both collagen filaments and anchoring fibril connections to the lamina densa were more numerous compared with the composite model. Our results may provide some insight into why, in clinical applications for treating burns and other wounds, composite grafts may exhibit surface instability and blistering for up to a year following grafting, and suggest the possible usefulness of the cell-sorted skin equivalent in future grafting applications.

  5. Prospective randomized comparison of scar appearances between cograft of acellular dermal matrix with autologous split-thickness skin and autologous split-thickness skin graft alone for full-thickness skin defects of the extremities.

    PubMed

    Yi, Ju Won; Kim, Jae Kwang

    2015-03-01

    The purpose of this study was to evaluate the clinical outcomes of cografting of acellular dermal matrix with autologous split-thickness skin and autologous split-thickness skin graft alone for full-thickness skin defects on the extremities. In this prospective randomized study, 19 consecutive patients with full-thickness skin defects on the extremities following trauma underwent grafting using either cograft of acellular dermal matrix with autologous split-thickness skin graft (nine patients, group A) or autologous split-thickness skin graft alone (10 patients, group B) from June of 2011 to December of 2012. The postoperative evaluations included observation of complications (including graft necrosis, graft detachment, or seroma formation) and Vancouver Scar Scale score. No statistically significant difference was found regarding complications, including graft necrosis, graft detachment, or seroma formation. At week 8, significantly lower Vancouver Scar Scale scores for vascularity, pliability, height, and total score were found in group A compared with group B. At week 12, lower scores for pliability and height and total scores were identified in group A compared with group B. For cases with traumatic full-thickness skin defects on the extremities, a statistically significant better result was achieved with cograft of acellular dermal matrix with autologous split-thickness skin graft than with autologous split-thickness skin graft alone in terms of Vancouver Scar Scale score. Therapeutic, II.

  6. An equation for the prediction of human skin permeability of neutral molecules, ions and ionic species.

    PubMed

    Zhang, Keda; Abraham, Michael H; Liu, Xiangli

    2017-04-15

    Experimental values of permeability coefficients, as log K p , of chemical compounds across human skin were collected by carefully screening the literature, and adjusted to 37°C for the effect of temperature. The values of log K p for partially ionized acids and bases were separated into those for their neutral and ionic species, forming a total data set of 247 compounds and species (including 35 ionic species). The obtained log K p values have been regressed against Abraham solute descriptors to yield a correlation equation with R 2 =0.866 and SD=0.432 log units. The equation can provide valid predictions for log K p of neutral molecules, ions and ionic species, with predictive R 2 =0.858 and predictive SD=0.445 log units calculated by the leave-one-out statistics. The predicted log K p values for Na + and Et 4 N + are in good agreement with the observed values. We calculated the values of log K p of ketoprofen as a function of the pH of the donor solution, and found that log K p markedly varies only when ketoprofen is largely ionized. This explains why models that neglect ionization of permeants still yield reasonable statistical results. The effect of skin thickness on log K p was investigated by inclusion of two indicator variables, one for intermediate thickness skin and one for full thickness skin, into the above equation. The newly obtained equations were found to be statistically very close to the above equation. Therefore, the thickness of human skin used makes little difference to the experimental values of log K p . Copyright © 2017 Elsevier B.V. All rights reserved.

  7. [Effects of human amniotic epithelial stem cells-derived exosomes on healing of wound with full-thickness skin defect in rats].

    PubMed

    Zhao, B; Wu, G F; Zhang, Y J; Zhang, W; Yang, F F; Xiao, D; Zeng, K X; Shi, J H; Su, L L; Hu, D H

    2017-01-20

    Objective: To investigate the effects of human amniotic epithelial stem cells-derived exosomes on healing of wound with full-thickness skin defect in rats. Methods: (1) Human amniotic epithelial stem cells were isolated from the amnion tissue of 5 full-term pregnant women in Department of Obstetrics of our hospital by the method of trypsin digestion, and their morphology was observed. The third passage of cells were stained with rhodamine-phalloidin for cytoskeleton observation. The third passage of cells were identified with flow cytometry through the detection of expressions of cell surface markers CD29, CD31, CD34, CD90, CD105, SSEA3, SSEA4 and immunity-related marker human leukocyte antigen-D related site (HLA-DR). The third passage of cells were also assessed the ability of adipogenic and osteogenic differentiation. (2) The third passage of human amniotic epithelial stem cells were cultured in DMEM medium supplemented with 10% exosome-free fetal bovine serum. Exosomes were isolated from culture supernatant by the method of ultracentrifugation and represented with scanning electron microscope for morphologic observation. (3) Six adult SD rats were anesthetized, and four 1 cm×1 cm sized wounds with full-thickness skin defect were made on the back of each rat. The wounds on the back of each rat were divided into control group, 25 μg/mL exosomes group, 50 μg/mL exosomes group, and 100 μg/mL exosomes group according to the random number table (with 6 wounds in each group), and a total volume of 100 μL phosphate buffered saline, 25 μg/mL exosomes, 50 μg/mL exosomes, and 100 μg/mL exosomes were evenly injected around the wound through multiple subcutaneous sites, respectively. The wound healing rate was calculated based on measurement on post injury day (PID) 7, 14, and 21. On PID 21, the healed wound tissue of each group was collected and stained with HE to observe and count skin accessories, and the arrangement of collagen fibers was observed with Masson staining. Data were processed with analysis of variance for repeated measurement, analysis of variance of randomized block design, one-way analysis of variance, and Bonferroni test. Results: (1) The cells, which were isolated and cultured, displayed typical cobblestone morphology with many microvilli on cell surface. Among the cells, the positive expression rates of CD29, CD90, SSEA3, and SSEA4 were above 50.0%, and the rate of CD105 was 8.0%, while the rates of CD31, CD34, and HLA-DR were almost 0. The cells could differentiate into adipocytes and osteoblasts. The above results revealed that the cells cultured were human amniotic epithelial stem cells. (2) Human amniotic epithelial stem cells-derived exosomes were round or oval vesicles with diameter from 50 to 150 nm. (3) On PID 7 and 21, wound healing rates of the four groups were close (with P values above 0.05). On PID 14, wound healing rates of 50 and 100 μg/mL exosomes groups were (89.8±4.3)% and (92.0±4.6)% respectively, significantly higher than the wound healing rate of control group [(80.3±6.4)%, P <0.05 or P <0.01]. Moreover, the wound healing rate of 100 μg/mL exosomes group was significantly higher than that of 25 μg/mL exosomes group [(83.3±5.1)%, P <0.05]. On PID 21, the numbers of skin accessories in 50 and 100 μg/mL exosomes groups were 4.3±1.4 and 5.1±1.6 respectively, obviously more than those of control group and 25 μg/mL exosomes group (respectively 1.4±0.5 and 1.8±0.6, with P values below 0.01). Well reorganized collagen fibers were observed just in the healed wound tissue of 50 and 100 μg/mL exosomes groups. Conclusions: Human amniotic epithelial stem cells-derived exosomes can promote healing of wound with full-thickness skin defect in rats.

  8. Reconstruction of full-thickness defects with bovine-derived collagen/elastin matrix: a series of challenging cases and the first reported post-burn facial reconstruction.

    PubMed

    Haik, Josef; Weissman, Oren; Hundeshagen, Gabriel; Farber, Nimrod; Harats, Moti; Rozenblatt, Shira M; Kamolz, Lars Peter; Winkler, Eyal; Zilinsky, Isaac

    2012-07-01

    Reconstruction of full-thickness defects may benefit from integration of dermal substitutes, which serve as a foundation for split-thickness skin grafts, thus enhancing short and long-term results. We present a series of 7 patients who were treated between 2010 and 2012 for complicated full-thickness defects by the second-generation collagen/elastin matrix Matriderm® covered by a split-thickness skin graft. The defects resulted from malignancy resection, trauma, and post-burn scar reconstruction. Overall graft take was excellent and no complications were noted regarding the dermal substitute. Graft quality was close to normal skin in terms of elasticity, pliability, texture, and color. Good contour and cushioning of defects in weight bearing areas was also achieved. Matriderm was found to be a useful adjunct to full-thickness defect reconstruction, especially in difficult areas where the desired result is a scar of the highest quality possible.

  9. Associations between cortical thickness and general intelligence in children, adolescents and young adults

    PubMed Central

    Menary, Kyle; Collins, Paul F.; Porter, James N.; Muetzel, Ryan; Olson, Elizabeth A.; Kumar, Vipin; Steinbach, Michael; Lim, Kelvin O.; Luciana, Monica

    2013-01-01

    Neuroimaging research indicates that human intellectual ability is related to brain structure including the thickness of the cerebral cortex. Most studies indicate that general intelligence is positively associated with cortical thickness in areas of association cortex distributed throughout both brain hemispheres. In this study, we performed a cortical thickness mapping analysis on data from 182 healthy typically developing males and females ages 9 to 24 years to identify correlates of general intelligence (g) scores. To determine if these correlates also mediate associations of specific cognitive abilities with cortical thickness, we regressed specific cognitive test scores on g scores and analyzed the residuals with respect to cortical thickness. The effect of age on the association between cortical thickness and intelligence was examined. We found a widely distributed pattern of positive associations between cortical thickness and g scores, as derived from the first unrotated principal factor of a factor analysis of Wechsler Abbreviated Scale of Intelligence (WASI) subtest scores. After WASI specific cognitive subtest scores were regressed on g factor scores, the residual score variances did not correlate significantly with cortical thickness in the full sample with age covaried. When participants were grouped at the age median, significant positive associations of cortical thickness were obtained in the older group for g-residualized scores on Block Design (a measure of visual-motor integrative processing) while significant negative associations of cortical thickness were observed in the younger group for g-residualized Vocabulary scores. These results regarding correlates of general intelligence are concordant with the existing literature, while the findings from younger versus older subgroups have implications for future research on brain structural correlates of specific cognitive abilities, as well as the cognitive domain specificity of behavioral performance correlates of normative gray matter thinning during adolescence. PMID:24744452

  10. Comparative cortical bone thickness between the long bones of humans and five common non-human mammal taxa.

    PubMed

    Croker, Sarah L; Reed, Warren; Donlon, Denise

    2016-03-01

    The task of identifying fragments of long bone shafts as human or non-human is difficult but necessary, for both forensic and archaeological cases, and a fast simple method is particularly useful. Previous literature suggests there may be differences in the thickness of the cortical bone between these two groups, but this has not been tested thoroughly. The aim of this study was not only to test this suggestion, but also to provide data that could be of practical assistance for future comparisons. The major limb bones (humerus, radius, femur and tibia) of 50 Caucasoid adult skeletons of known age and sex were radiographed, along with corresponding skeletal elements from sheep, pigs, cattle, large dogs and kangaroos. Measurements were taken from the radiographs at five points along the bone shaft, of shaft diameter, cortical bone thickness, and a cortical thickness index (sum of cortices divided by shaft diameter) in both anteroposterior and mediolateral orientations. Each variable for actual cortical bone thickness as well as cortical thickness indices were compared between the human group (split by sex) and each of the non-human groups in turn, using Student's t-tests. Results showed that while significant differences did exist between the human groups and many of the non-human groups, these were not all in the same direction. That is, some variables in the human groups were significantly greater than, and others were significantly less than, the corresponding variable in the non-human groups, depending on the particular non-human group, sex of the human group, or variable under comparison. This was the case for measurements of both actual cortical bone thickness and cortical thickness index. Therefore, for bone shaft fragments for which the skeletal element is unknown, the overlap in cortical bone thickness between different areas of different bones is too great to allow identification using this method alone. However, by providing extensive cortical bone thickness data for a range of bones, this study may be able to assist in the identification of some bone fragments by providing another piece of evidence that, used in conjunction with other clues, can provide a likely determination of the origin of a bone fragment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. In vitro 3D full thickness skin equivalent tissue model using silk and collagen biomaterials

    PubMed Central

    Bellas, Evangelia; Seiberg, Miri; Garlick, Jonathan; Kaplan, David L.

    2013-01-01

    Current approaches to develop skin equivalents often only include the epidermal and dermal components. Yet, full thickness skin includes the hypodermis, a layer below the dermis of adipose tissue containing vasculature, nerves and fibroblasts, necessary to support the epidermis and dermis. In the present study, we developed a full thickness skin equivalent including an epidermis, dermis and hypodermis that could serve as an in vitro model for studying skin development, disease or as a platform for consumer product testing as a means to avoid animal testing. The full thickness skin equivalent was easy to handle and was maintained in culture for greater than 14 days while expressing physiologically relevant morphologies of both the epidermis and dermis, as seen by keratin 10, collagen I and collagen IV expression. The skin equivalent produced glycerol and leptin, markers of adipose tissue metabolism. This work serves as a foundation for our understanding of some of the necessary factors needed to develop a stable, functional model of full-thickness skin. PMID:23161763

  12. Development of a reconstructed cornea from collagen-chondroitin sulfate foams and human cell cultures.

    PubMed

    Vrana, N Engin; Builles, Nicolas; Justin, Virginie; Bednarz, Jurgen; Pellegrini, Graziella; Ferrari, Barbara; Damour, Odile; Hulmes, David J S; Hasirci, Vasif

    2008-12-01

    To develop an artificial cornea, the ability to coculture the different cell types present in the cornea is essential. Here the goal was to develop a full-thickness artificial cornea using an optimized collagen-chondroitin sulfate foam, with a thickness close to that of human cornea, by coculturing human corneal epithelial and stromal cells and transfected human endothelial cells. Corneal extracellular matrix was simulated by a porous collagen/glycosaminoglycan-based scaffold seeded with stromal keratocytes and then, successively, epithelial and endothelial cells. Scaffolds were characterized for bulk porosity and pore size distribution. The performance of the three-dimensional construct was studied by histology, immunofluorescence, and immunohistochemistry. The scaffold had 85% porosity and an average pore size of 62.1 microm. Keratocytes populated the scaffold and produced a newly synthesized extracellular matrix as characterized by immunohistochemistry. Even though the keratocytes lost their CD34 phenotype marker, the absence of smooth muscle actin fibers showed that these cells had not differentiated into myofibroblasts. The epithelial cells formed a stratified epithelium and began basement membrane deposition. An endothelial cell monolayer beneath the foam was also apparent. These results demonstrate that collagen-chondroitin sulfate scaffolds are good substrates for artificial cornea construction with good resilience, long-term culture capability, and handling properties.

  13. In vivo characterization of structural changes after topical application of glucocorticoids in healthy human skin

    NASA Astrophysics Data System (ADS)

    Jung, Sora; Lademann, Jürgen; Darvin, Maxim E.; Richter, Claudia; Pedersen, Claus Bang; Richter, Heike; Schanzer, Sabine; Kottner, Jan; Blume-Peytavi, Ulrike; Røpke, Mads Almose

    2017-07-01

    Topical glucocorticoids (GC) are known to induce changes in human skin with the potential to develop skin atrophy. Here, atrophogenic effects and subsequent structural changes in the skin after topical application of GC were investigated in vivo. Sixteen healthy volunteers were topically treated daily on the forearms with clobetasol propionate, betamethasone dipropionate, and the petrolatum vehicle for 4 weeks. All treated skin areas and a nontreated control area were examined by ultrasound, optical coherence tomography, confocal laser scanning microscopy, multiphoton tomography (MPT), and resonance Raman spectroscopy at baseline 1 day after last application and 1 week after last application. Investigated parameters included stratum corneum thickness, epidermal, and full skin thickness, keratinocyte size and density, keratinocyte nucleus-to-cytoplasm ratio, skin surface classification, relative collagen and elastin signal intensity, second-harmonic generation-to-autofluorescence aging index of dermis (SAAID), and the antioxidant status of the skin. A reduction in epidermal and dermal skin thickness was observed in GC treated as well as in vehicle-treated and untreated skin areas on the volar forearm. MPT analysis showed an increased epidermal cell density and reduced cell size and nucleus-to-cytoplasm ratio and a significant increase of SAAID after GC treatment indicating a restructuring or compression of collagen fibers clinically being observed as atrophic changes.

  14. Femtosecond laser subsurface scleral treatment in cadaver human sclera and evaluation using two-photon and confocal microscopy

    NASA Astrophysics Data System (ADS)

    Sun, Hui; Fan, Zhongwei; Yan, Ying; Lian, Fuqiang; Kurtz, Ron; Juhasz, Tibor

    2016-03-01

    Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial-thickness drainage channels can be created with femtosecond laser in the translucent sclera for the potential treatment of glaucoma. We demonstrate the creation of partial-thickness subsurface drainage channels with the femtosecond laser in the cadaver human eyeballs and describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. A femtosecond laser operating at a wavelength of 1700 nm was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of cadaver human eyes. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such partial thickness subsurface scleral channels. Our studies suggest that the confocal and two-photon microscopy can be used to investigate femtosecond-laser created partial-thickness drainage channels in the sclera of cadaver human eyes.

  15. Multichannel noninvasive human-machine interface via stretchable µm thick sEMG patches for robot manipulation

    NASA Astrophysics Data System (ADS)

    Zhou, Ying; Wang, Youhua; Liu, Runfeng; Xiao, Lin; Zhang, Qin; Huang, YongAn

    2018-01-01

    Epidermal electronics (e-skin) emerging in recent years offer the opportunity to noninvasively and wearably extract biosignals from human bodies. The conventional processes of e-skin based on standard microelectronic fabrication processes and a variety of transfer printing methods, nevertheless, unquestionably constrains the size of the devices, posing a serious challenge to collecting signals via skin, the largest organ in the human body. Herein we propose a multichannel noninvasive human-machine interface (HMI) using stretchable surface electromyography (sEMG) patches to realize a robot hand mimicking human gestures. Time-efficient processes are first developed to manufacture µm thick large-scale stretchable devices. With micron thickness, the stretchable µm thick sEMG patches show excellent conformability with human skin and consequently comparable electrical performance with conventional gel electrodes. Combined with the large-scale size, the multichannel noninvasive HMI via stretchable µm thick sEMG patches successfully manipulates the robot hand with eight different gestures, whose precision is as high as conventional gel electrodes array.

  16. Growth factors in porcine full and partial thickness burn repair. Differing targets and effects of keratinocyte growth factor, platelet-derived growth factor-BB, epidermal growth factor, and neu differentiation factor.

    PubMed Central

    Danilenko, D. M.; Ring, B. D.; Tarpley, J. E.; Morris, B.; Van, G. Y.; Morawiecki, A.; Callahan, W.; Goldenberg, M.; Hershenson, S.; Pierce, G. F.

    1995-01-01

    The topical application of recombinant growth factors such as epidermal growth factor, platelet-derived growth factor-BB homodimer (rPDGF-BB), keratinocyte growth factor (rKGF), and neu differentiation factor has resulted in significant acceleration of healing in several animal models of wound repair. In this study, we established highly reproducible and quantifiable full and deep partial thickness porcine burn models in which burns were escharectomized 4 or 5 days postburn and covered with an occlusive dressing to replicate the standard treatment in human burn patients. We then applied these growth factors to assess their efficacy on several parameters of wound repair: extracellular matrix and granulation tissue production, percent reepithelialization, and new epithelial area. In full thickness burns, only rPDGF-BB and the combination of rPDGF-BB and rKGF induced significant changes in burn repair. rPDGF-BB induced marked extracellular matrix and granulation tissue production (P = 0.013) such that the burn defect was filled within several days of escharectomy, but had no effect on new epithelial area or reepithelialization. The combination of rPDGF-BB and rKGF in full thickness burns resulted in a highly significant increase in extracellular matrix and granulation tissue area (P = 0.0009) and a significant increase in new epithelial area (P = 0.007), but had no effect on reepithelialization. In deep partial thickness burns, rKGF induced the most consistent changes. Daily application of rKGF induced a highly significant increase in new epithelial area (P < 0.0001) but induced only a modest increase in reepithelialization (83.7% rKGF-treated versus 70.2% control; P = 0.016) 12 days postburn. rKGF also doubled the number of fully reepithelialized burns (P = 0.02) at 13 days postburn, at least partially because of marked stimulation of both epidermal and follicular proliferation as assessed by proliferating cell nuclear antigen expression. In situ hybridization for KGFR in porcine burns revealed strong expression of KGFR on hair follicles and basal epidermis, confirming direct rKGF action on follicular as well as epidermal keratinocytes. Although the epithelial proliferation induced by rKGF resulted in marked neoepidermal psoriasiform hyperplasia with exaggerated rete ridges and neoepidermal and follicular maturation as assessed by expression of cytokeratin 10, a marker of keratinocyte terminal differentiation was not delayed and appeared to be accelerated in some rKGF-treated burns. Recombinant epidermal growth factor induced a trend toward increased new epithelial area in deep partial thickness burns, but had no effect on reepithelialization. The recombinant neu differentiation factor-alpha 2 isoform had no significant biological effects in either full or deep partial thickness burns.(ABSTRACT TRUNCATED AT 250 WORDS) Images Figure 1 Figure 2 Figure 4 Figure 7 Figure 8 PMID:7485390

  17. Integrated carbon fiber electrodes within hollow polymer microneedles for transdermal electrochemical sensing

    PubMed Central

    Miller, Philip R.; Gittard, Shaun D.; Edwards, Thayne L.; Lopez, DeAnna M.; Xiao, Xiaoyin; Wheeler, David R.; Monteiro-Riviere, Nancy A.; Brozik, Susan M.; Polsky, Ronen; Narayan, Roger J.

    2011-01-01

    In this study, carbon fiber electrodes were incorporated within a hollow microneedle array, which was fabricated using a digital micromirror device-based stereolithography instrument. Cell proliferation on the acrylate-based polymer used in microneedle fabrication was examined with human dermal fibroblasts and neonatal human epidermal keratinocytes. Studies involving full-thickness cadaveric porcine skin and trypan blue dye demonstrated that the hollow microneedles remained intact after puncturing the outermost layer of cadaveric porcine skin. The carbon fibers underwent chemical modification in order to enable detection of hydrogen peroxide and ascorbic acid; electrochemical measurements were demonstrated using integrated electrode-hollow microneedle devices. PMID:21522504

  18. Full-thickness knee articular cartilage defects in national football league combine athletes undergoing magnetic resonance imaging: prevalence, location, and association with previous surgery.

    PubMed

    Nepple, Jeffrey J; Wright, Rick W; Matava, Matthew J; Brophy, Robert H

    2012-06-01

    To better define the prevalence and location of full-thickness articular cartilage lesions in elite football players undergoing knee magnetic resonance imaging (MRI) at the National Football League (NFL) Invitational Combine and assess the association of these lesions with previous knee surgery. We performed a retrospective review of all participants in the NFL Combine undergoing a knee MRI scan from 2005 to 2009. Each MRI scan was reviewed for evidence of articular cartilage disease. History of previous knee surgery including anterior cruciate ligament reconstruction, meniscal procedures, and articular cartilage surgery was recorded for each athlete. Knees with a history of previous articular cartilage restoration surgery were excluded from the analysis. A total of 704 knee MRI scans were included in the analysis. Full-thickness articular cartilage lesions were associated with a history of any previous knee surgery (P < .001) and, specifically, previous meniscectomy (P < .001) but not with anterior cruciate ligament reconstruction (P = .7). Full-thickness lesions were present in 27% of knees with a previous meniscectomy compared with 12% of knees without any previous meniscal surgery. Full-thickness lesions in the lateral compartment were associated with previous lateral meniscectomy (P < .001); a similar relation was seen for medial meniscus tears in the medial compartment (P = .01). Full-thickness articular cartilage lesions of the knee were present in 17.3% of elite American football players at the NFL Combine undergoing MRI. The lateral compartment appears to be at greater risk for full-thickness cartilage loss. Previous knee surgery, particularly meniscectomy, is associated with these lesions. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Evaluating outcomes of endoscopic full-thickness plication for gastroesophageal reflux disease (GERD) with impedance monitoring.

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel

    2010-05-01

    Endoscopic full-thickness plication allows transmural suturing at the gastroesophageal junction to recreate the antireflux barrier. Multichannel intraluminal impedance monitoring (MII) can be used to detect nonacid or weakly acidic reflux, acidic swallows, and esophageal clearance time. This study used MII to evaluate the outcome of endoscopic full-thickness plication. In this study, 12 subsequent patients requiring maintenance proton pump inhibitor therapy underwent endoscopic full-thickness plication for treatment of gastroesophageal reflux disease. With patients off medication, MII was performed before and 6-months after endoscopic full-thickness plication. The total median number of reflux episodes was significantly reduced from 105 to 64 (p = 0.016). The median number of acid reflux episodes decreased from 73 to 43 (p = 0.016). Nonacid reflux episodes decreased from 23 to 21 (p = 0.306). The median bolus clearance time was 12 s before treatment and 11 s at 6 months (p = 0.798). The median acid exposure time was reduced from 6.8% to 3.4% (p = 0.008), and the DeMeester scores were reduced from 19 to 12 (p = 0.008). Endoscopic full-thickness plication significantly reduced total reflux episodes, acid reflux episodes, and total reflux exposure time. The DeMeester scores and total acid exposure time for the distal esophagus were significantly improved. No significant changes in nonacid reflux episodes and median bolus clearance time were encountered.

  20. Effect of piracetam and nimodipine on full-thickness skin burns in rabbits.

    PubMed

    Sari, Elif; Dincel, Gungor C

    2016-08-01

    The potential of several drugs for full-thickness skin burns has been investigated, but the treatment of such burns remains a challenge in plastic surgery. The present study was designed to determine the effect of systemic and topical administration of piracetam and nimodipine on full-thickness skin burn wound healing. A total of 36 New Zealand male rabbits were divided into six groups. Full-thickness skin burns were produced in all the groups, except the control group. Piracetam was administered systemically (piracetam-IV) and topically (piracetam-C) for 14 days, and nimodipine was administered systemically (nimodipine-IV) and topically (nimodipine-C) over the burn wounds for 14 days. The sham group underwent burn injury but was not administered any drug. After 21 days, gross examination and histopathological analysis were performed and the results were compared statistically. Nimodipine-C and nimodipine-IV had no effect on burn wound healing. However, both piracetam-IV and piracetam-C significantly enhanced the healing of the full-thickness skin burn wounds, although the latter was more effective, useful and practical in burn wound healing. The histopathological features of the wounds in the piracetam-C group were closer to those of the control group than those of the other groups. Piracetam-C rather than piracetam-IV may promote full-thickness burn wound healing in rabbits. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. An In Vitro Skin Equivalent for Evaluation of Skin Absorption of Compounds

    DTIC Science & Technology

    2008-12-01

    1023-1033. Uchida, Y., M. Behne, D. Quiec, P. M. Elias, and W. M. Holleran, 2001: Vitamin C Stimulates Sphingolipid Production and Markers of...dermal fibroblasts and human keratinocytes, and conditions such as addition of ascorbic acid are being used to look at effects on morphogenesis...and Epiderm FT ® (Full thickness SE) (MatTek Corporation, Ashland MA, USA) (Bernard, F.- X., Barrault, C . et al. 2000;Boelsma, E., Gibbs, S. et al

  2. Use of cultured human epidermal keratinocytes for allografting burns and conditions for temporary banking of the cultured allografts.

    PubMed

    Bolívar-Flores, J; Poumian, E; Marsch-Moreno, M; Montes de Oca, G; Kuri-Harcuch, W

    1990-02-01

    Five children who suffered burns clinically regarded as full skin thickness loss were grafted with cultured allogeneic skin from newborn prepuce. The wounds had remained open and infected without healing for about 20 days before the patients were received in the burn unit. To avoid losing surviving deep epidermal cells the wounds were débrided but not deeply excised and, a few days before allografting, they were washed with isodine solution and sterile water, and treated with silvadene cream application. All children received 76 cultured allografts of about 60 cm2 each. After allografting, the wounds were epithelized in 7-10 days and the allogeneic grafted skin began desquamation suggesting that the allograft did not 'take' permanently but was replaced by the newly formed skin. On the other hand, since allografting is an adequate therapy to provide early temporary coverage in extensively burned patients, we developed conditions for banking cultured skin to make it available for immediate use. The conditions described allow banking of the cultured grafts for 15-20 days with retention of clonal growth ability similar to that of unstored epithelia. The results show that cultured epidermal cells obtained from human newborn foreskin, when used as allografts for coverage of full skin or deep partial skin thickness burns, allow rapid epithelization of the burn wounds.

  3. Randomized, Paired-site Comparison of Autologous Engineered Skin Substitutes and Split-thickness Skin Graft for Closure of Extensive, Full-thickness Burns

    PubMed Central

    Boyce, Steven T.; Simpson, Peggy S.; Rieman, Mary T.; Warner, Petra M.; Yakuboff, Kevin P.; Bailey, J. Kevin; Nelson, Judith K.; Fowler, Laura A.; Kagan, Richard J.

    2016-01-01

    Objectives Stable closure of full-thickness burn wounds remains a limitation to recovery from burns of greater than 50% of the total body surface area (TBSA). Hypothetically, engineered skin substitutes (ESS) consisting of autologous keratinocytes and fibroblasts attached to collagen-based scaffolds may reduce requirements for donor skin, and decrease mortality. Methods ESS were prepared from split-thickness skin biopsies collected after enrollment of 16 pediatric burn patients into an approved study protocol. ESS and split-thickness autograft (AG) were applied to 15 subjects with full-thickness burns involving a mean of 76.9% TBSA. Data consisted of photographs, tracings of donor skin and healed wounds, comparison of mortality with the National Burn Repository (NBR), correlation of TBSA closed wounds with TBSA full-thickness burn, frequencies of regrafting, and immunoreactivity to the biopolymer scaffold. Results One subject expired before ESS application, and 15 subjects received 2056 ESS grafts. The ratio of closed wound to donor areas was 108.7±9.7 for ESS compared with a maximum of 4.0±0.0 for AG. Mortality for enrolled subjects was 6.25%, and 30.3% for a comparable population from the NBR (p<0.05). Engraftment was 83.5±2.0% for ESS and 96.5±0.9 for AG. Percentage TBSA closed was 29.9±3.3% for ESS, and 47.0±2.0 for AG. These values were significantly different between the graft types. Correlation of % TBSA closed with ESS with % TBSA full-thickness burn generated an R2 value of 0.65 (p<0.001). Conclusions These results indicate that autologous ESS reduce mortality and requirements for donor skin harvesting, for grafting of full-thickness burns of greater than 50% TBSA. PMID:27404165

  4. Randomized, Paired-Site Comparison of Autologous Engineered Skin Substitutes and Split-Thickness Skin Graft for Closure of Extensive, Full-Thickness Burns.

    PubMed

    Boyce, Steven T; Simpson, Peggy S; Rieman, Mary T; Warner, Petra M; Yakuboff, Kevin P; Bailey, J Kevin; Nelson, Judith K; Fowler, Laura A; Kagan, Richard J

    Stable closure of full-thickness burn wounds remains a limitation to recovery from burns of greater than 50% of the total body surface area (TBSA). Hypothetically, engineered skin substitutes (ESS) consisting of autologous keratinocytes and fibroblasts attached to collagen-based scaffolds may reduce requirements for donor skin, and decrease mortality. ESS were prepared from split-thickness skin biopsies collected after enrollment of 16 pediatric burn patients into an approved study protocol. ESS and split-thickness autograft (AG) were applied to 15 subjects with full-thickness burns involving a mean of 76.9% TBSA. Data consisted of photographs, tracings of donor skin and healed wounds, comparison of mortality with the National Burn Repository, correlation of TBSA closed wounds with TBSA full-thickness burn, frequencies of regrafting, and immunoreactivity to the biopolymer scaffold. One subject expired before ESS application, and 15 subjects received 2056 ESS grafts. The ratio of closed wound to donor areas was 108.7 ± 9.7 for ESS compared with a maximum of 4.0 ± 0.0 for AG. Mortality for enrolled subjects was 6.25%, and 30.3% for a comparable population from the National Burn Repository (P < .05). Engraftment was 83.5 ± 2.0% for ESS and 96.5 ± 0.9% for AG. Percentage TBSA closed was 29.9 ± 3.3% for ESS, and 47.0 ± 2.0% for AG. These values were significantly different between the graft types. Correlation of % TBSA closed with ESS with % TBSA full-thickness burn generated an R value of 0.65 (P < .001). These results indicate that autologous ESS reduce mortality and requirements for donor skin harvesting, for grafting of full-thickness burns of greater than 50% TBSA.

  5. Bioengineering methods employed in the study of wound healing of sulphur mustard burns.

    PubMed

    Graham, John S; Schomacker, Kevin T; Glatter, Robert D; Briscoe, Crystal M; Braue, Ernest H; Squibb, Katherine S

    2002-02-01

    Sulphur mustard (SM) is a potent incapacitating chemical warfare agent that remains a threat to war fighters and civilians worldwide. SM lesions may require weeks or months to heal, depending upon their severity. This study was undertaken to find a treatment regimen that promotes speedier healing of deep cutaneous SM burns in a weanling pig model. The principal objective of the study was to compare four treatment regimens and establish which achieved the shortest healing time. Twelve Yorkshire Cross weanling pigs were exposed to SM liquid for 2h, generating six large deep dermal/full thickness burns on the ventrum of each animal. Three additional animals served as sham-exposed controls. Surgical intervention occurred at 48 h postexposure. Treatments included: (i) full-thickness debridement of the burns with a computer controlled, raster scanned continuous wave CO2 laser followed by autologous split-thickness skin grafting; (ii) full-thickness sharp surgical tangential excision followed by skin grafting, the 'Gold Standard' used in human deep dermal/full-thickness thermal burns management; (iii) partial-thickness laser ablation with no grafting; and (iv) partial-thickness sharp surgical excision with no grafting. Several non-invasive bioengineering methods were used to monitor the progress of wound healing throughout a 36-day healing period: reflectance colourimetry, evaporimetry, laser Doppler perfusion imaging and ballistometry. Bioengineering methods indicated that laser debridement followed by autologous split-thickness skin grafting was as efficacious in improving the wound healing of deep SM burns in weanling swine as the 'Gold Standard.' Regardless of the method of debridement, barrier function, skin colour and mechanical properties returned to near-normal levels within 15 days of treatment in the grafted sites. Regardless of surgical approach, blood flux levels remained approximately 50-60% of normal tissue throughout the 36-day postsurgical observation period. Mid-dermal debridement by sharp surgical tangential excision or laser ablation without the use of skin grafts did not produce as good a result as those attained through the use of grafts, but was better than no surgical treatment of the wounds. Bioengineering methods were useful in evaluating multiple characteristics during wound healing: (i) reflectance colourimetry for skin colour, (ii) evaporimetry to measure transepidermal water loss as an indicator of barrier function, (iii) laser Doppler perfusion imaging to assess cutaneous blood flow, and (iv) ballistometry to measure the mechanical properties of skin hardness and elasticity. Perhaps the most useful method was evaporimetry, as a restored barrier function was the best indicator of healed wounds. The use of reflectance colourimetry and ballistometry will continue in future wound healing studies for their contributions in judging cosmetic and functional outcomes. While useful, laser Doppler perfusion imaging was found to be rather time consuming. This methodology will be limited in the future to burn depth estimation prior to treatment, and for evaluation of pharmaceuticals specifically designed to improve or sustain blood flow into damaged areas.

  6. β1 Integrins Mediate Attachment of Mesenchymal Stem Cells to Cartilage Lesions

    PubMed Central

    Zwolanek, Daniela; Flicker, Magdalena; Kirstätter, Elisabeth; Zaucke, Frank; van Osch, Gerjo J.V.M.; Erben, Reinhold G.

    2015-01-01

    Abstract Mesenchymal stem cells (MSC) may have great potential for cell-based therapies of osteoarthritis. However, after injection in the joint, only few cells adhere to defective articular cartilage and contribute to cartilage regeneration. Little is known about the molecular mechanisms of MSC attachment to defective articular cartilage. Here, we developed an ex vivo attachment system, using rat osteochondral explants with artificially created full-thickness cartilage defects in combination with genetically labeled MSC isolated from bone marrow of human placental alkaline phosphatase transgenic rats. Binding of MSC to full-thickness cartilage lesions was improved by serum, but not hyaluronic acid, and was dependent on the presence of divalent cations. Additional in vitro tests showed that rat MSC attach, in a divalent cation-dependent manner, to collagen I, collagen II, and fibronectin, but not to collagen XXII or cartilage oligomeric matrix protein (COMP). RGD peptides partially blocked the adhesion of MSC to fibronectin in vitro and to cartilage lesions ex vivo. Furthermore, the attachment of MSC to collagen I and II in vitro and to cartilage lesions ex vivo was almost completely abolished in the presence of a β1 integrin blocking antibody. In conclusion, our data suggest that attachment of MSC to ex vivo full-thickness cartilage lesions is almost entirely β1 integrin-mediated, whereby both RGD- and collagen-binding integrins are involved. These findings suggest a key role of integrins during MSC attachment to defective cartilage and may pave the way for improved MSC-based therapies in the future. PMID:26309781

  7. Antecedent thermal injury worsens split-thickness skin graft quality: A clinically relevant porcine model of full-thickness burn, excision and grafting.

    PubMed

    Carlsson, Anders H; Rose, Lloyd F; Fletcher, John L; Wu, Jesse C; Leung, Kai P; Chan, Rodney K

    2017-02-01

    Current standard of care for full-thickness burn is excision followed by autologous split-thickness skin graft placement. Skin grafts are also frequently used to cover surgical wounds not amenable to linear closure. While all grafts have potential to contract, clinical observation suggests that antecedent thermal injury worsens contraction and impairs functional and aesthetic outcomes. This study evaluates the impact of antecedent full-thickness burn on split-thickness skin graft scar outcomes and the potential mediating factors. Full-thickness contact burns (100°C, 30s) were created on the backs of anesthetized female Yorkshire Pigs. After seven days, burn eschar was tangentially excised and covered with 12/1000th inch (300μm) split-thickness skin graft. For comparison, unburned wounds were created by sharp excision to fat before graft application. From 7 to 120days post-grafting, planimetric measurements, digital imaging and biopsies for histology, immunohistochemistry and gene expression were obtained. At 120days post-grafting, the Observer Scar Assessment Scale, colorimetry, contour analysis and optical graft height assessments were performed. Twenty-nine porcine wounds were analyzed. All measured metrics of clinical skin quality were significantly worse (p<0.05) in burn injured wounds. Histological analysis supported objective clinical findings with marked scar-like collagen proliferation within the dermis, increased vascular density, and prolonged and increased cellular infiltration. Observed differences in contracture also correlated with earlier and more prominent myofibroblast differentiation as demonstrated by α-SMA staining. Antecedent thermal injury worsens split-thickness skin graft quality, likely by multiple mechanisms including burn-related inflammation, microscopically inadequate excision, and dysregulation of tissue remodeling. A valid, reliable, clinically relevant model of full-thickness burn, excision and skin replacement therapy has been demonstrated. Future research to enhance quality of skin replacement therapies should be directed toward modulation of inflammation and assessments for complete excision. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  8. Cranial vault thickness in primates: Homo erectus does not have uniquely thick vault bones.

    PubMed

    Copes, Lynn E; Kimbel, William H

    2016-01-01

    Extremely thick cranial vaults have been noted as a diagnostic characteristic of Homo erectus since the first fossil of the species was identified, but relatively little work has been done on elucidating its etiology or variation across fossils, living humans, or extant non-human primates. Cranial vault thickness (CVT) is not a monolithic trait, and the responsiveness of its layers to environmental stimuli is unknown. We obtained measurements of cranial vault thickness in fossil hominins from the literature and supplemented those data with additional measurements taken on African fossil specimens. Total CVT and the thickness of the cortical and diploë layers individually were compared to measures of CVT in extant species measured from more than 500 CT scans of human and non-human primates. Frontal and parietal CVT in fossil primates was compared to a regression of CVT on cranial capacity calculated for extant species. Even after controlling for cranial capacity, African and Asian H. erectus do not have uniquely high frontal or parietal thickness residuals, either among hominins or extant primates. Extant primates with residual CVT thickness similar to or exceeding H. erectus (depending on the sex and bone analyzed) include Nycticebus coucang, Perodicticus potto, Alouatta caraya, Lophocebus albigena, Galago alleni, Mandrillus sphinx, and Propithecus diadema. However, the especially thick vaults of extant non-human primates that overlap with H. erectus values are composed primarily of cortical bone, while H. erectus and other hominins have diploë-dominated vault bones. Thus, the combination of thick vaults comprised of a thickened diploë layer may be a reliable autapomorphy for members of the genus Homo. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Multilayered Electrospun Scaffolds for Tendon Tissue Engineering

    PubMed Central

    Chainani, Abby; Hippensteel, Kirk J.; Kishan, Alysha; Garrigues, N. William; Ruch, David S.; Guilak, Farshid

    2013-01-01

    Full-thickness rotator cuff tears are one of the most common causes of shoulder pain in people over the age of 65. High retear rates and poor functional outcomes are common after surgical repair, and currently available extracellular matrix scaffold patches have limited abilities to enhance new tendon formation. In this regard, tissue-engineered scaffolds may provide a means to improve repair of rotator cuff tears. Electrospinning provides a versatile method for creating nanofibrous scaffolds with controlled architectures, but several challenges remain in its application to tissue engineering, such as cell infiltration through the full thickness of the scaffold as well as control of cell growth and differentiation. Previous studies have shown that ligament-derived extracellular matrix may enhance differentiation toward a tendon or ligament phenotype by human adipose stem cells (hASCs). In this study, we investigated the use of tendon-derived extracellular matrix (TDM)-coated electrospun multilayered scaffolds compared to fibronectin (FN) or phosphate-buffered saline (PBS) coating for use in rotator cuff tendon tissue engineering. Multilayered poly(ɛ-caprolactone) scaffolds were prepared by sequentially collecting electrospun layers onto the surface of a grounded saline solution into a single scaffold. Scaffolds were then coated with TDM, FN, or PBS and seeded with hASCs. Scaffolds were maintained without exogenous growth factors for 28 days in culture and evaluated for protein content (by immunofluorescence and biochemical assay), markers of tendon differentiation, and tensile mechanical properties. The collagen content was greatest by day 28 in TDM-scaffolds. Gene expression of type I collagen, decorin, and tenascin C increased over time, with no effect of scaffold coating. Sulfated glycosaminoglycan and dsDNA contents increased over time in culture, but there was no effect of scaffold coating. The Young's modulus did not change over time, but yield strain increased with time in culture. Histology demonstrated cell infiltration through the full thickness of all scaffolds and immunofluorescence demonstrated greater expression of type I, but not type III collagen through the full thickness of the scaffold in TDM-scaffolds compared to other treatment groups. Together, these data suggest that nonaligned multilayered electrospun scaffolds permit tenogenic differentiation by hASCs and that TDM may promote some aspects of this differentiation. PMID:23808760

  10. Repair of full-thickness cartilage defects with cells of different origin in a rabbit model.

    PubMed

    Yan, Hui; Yu, Changlong

    2007-02-01

    The purpose of this study was to evaluate the repaired tissues formed in full-thickness cartilage defects in a rabbit model implanted with 4 types of chondrogenic cells, including chondrocytes, mesenchymal stem cells (MSCs) and fibroblasts from rabbit, and human umbilical cord blood (hUCB) stem cells. Chondrocytes, MSCs, and fibroblasts were isolated from 6-week-old New Zealand rabbits; hUCB stem cells were isolated from the umbilical cord blood of newborn children. These 4 types of cells were cultured in vitro and embedded in polylactic acid (PLA) matrices. Full-thickness defects were produced in the femoral trochlear grooves of both knees in 36 adult New Zealand White rabbits. Cell/PLA composites were transplanted into cartilage defects. A total of 5 groups were formed according to implanted cell type: Group A, chondrocytes; Group B, MSCs; Group C, fibroblasts; Group D, hUCB stem cells; and Group E, no cells (control group). Repaired tissues were evaluated grossly, histologically, and immunohistochemically at 6 weeks and 12 weeks after implantation. In Groups A and B, defects were repaired with hyaline-like cartilage. In Group C, defects were repaired with fibrous tissue. In Group D, defects were repaired primarily with fibrous tissue and scattered chondrocytes; in some specimens, defects were repaired with a thin layer of hyaline-like cartilage at 12 weeks. In Group E, defects were repaired with fibrous tissue. Histologic scores in Groups A and B were significantly higher than those in Groups C, D, and E at 6 and 12 weeks after transplantation. Full-thickness cartilage defects treated with chondrocyte or MSC transplantation were repaired with hyaline-like cartilage tissue, and repair was significantly better than in tissues treated with fibroblasts and hUCB stem cells, as well as in the control group. Repaired tissues treated with MSCs appeared to have better cell arrangement, subchondral bone remodeling, and integration with surrounding cartilage than did repaired tissues generated by chondrocyte implantation. MSCs might be the most suitable cell source for cartilage repair. Further investigation into hUCB stem cell transplantation is needed. In our study of rabbits, MSCs supplied the most promising cell source for cartilage repair.

  11. Wound dressings composed of copper-doped borate bioactive glass microfibers stimulate angiogenesis and heal full-thickness skin defects in a rodent model.

    PubMed

    Zhao, Shichang; Li, Le; Wang, Hui; Zhang, Yadong; Cheng, Xiangguo; Zhou, Nai; Rahaman, Mohamed N; Liu, Zhongtang; Huang, Wenhai; Zhang, Changqing

    2015-01-01

    There is a need for better wound dressings that possess the requisite angiogenic capacity for rapid in situ healing of full-thickness skin wounds. Borate bioactive glass microfibers are showing a remarkable ability to heal soft tissue wounds but little is known about the process and mechanisms of healing. In the present study, wound dressings composed of borate bioactive glass microfibers (diameter = 0.4-1.2 μm; composition 6Na2O, 8K2O, 8MgO, 22CaO, 54B2O3, 2P2O5; mol%) doped with 0-3.0 wt.% CuO were created and evaluated in vitro and in vivo. When immersed in simulated body fluid, the fibers degraded and converted to hydroxyapatite within ∼7 days, releasing ions such as Ca, B and Cu into the medium. In vitro cell culture showed that the ionic dissolution product of the fibers was not toxic to human umbilical vein endothelial cells (HUVECs) and fibroblasts, promoted HUVEC migration, tubule formation and secretion of vascular endothelial growth factor (VEGF), and stimulated the expression of angiogenic-related genes of the fibroblasts. When used to treat full-thickness skin defects in rodents, the Cu-doped fibers (3.0 wt.% CuO) showed a significantly better capacity to stimulate angiogenesis than the undoped fibers and the untreated defects (control) at 7 and 14 days post-surgery. The defects treated with the Cu-doped and undoped fibers showed improved collagen deposition, maturity and orientation when compared to the untreated defects, the improvement shown by the Cu-doped fibers was not markedly better than the undoped fibers at 14 days post-surgery. These results indicate that the Cu-doped borate glass microfibers have a promising capacity to stimulate angiogenesis and heal full-thickness skin defects. They also provide valuable data for understanding the role of the microfibers in healing soft tissue wounds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Full-thickness myotomy is associated with higher rate of postoperative gastroesophageal reflux disease

    PubMed Central

    Wang, Xue-Hong; Tan, Yu-Yong; Zhu, Hong-Yi; Li, Chen-Jie; Liu, De-Liang

    2016-01-01

    AIM To compare long-term occurrence of gastroesophageal reflux disease (GERD) between two different types of peroral endoscopic myotomy (POEM) for achalasia. METHODS We included all patients with achalasia who underwent POEM at our hospital from August 2011 to October 2012 and had complete GERD evaluation with ≥ 3 years of follow-up. They were divided into circular or full-thickness myotomy groups according to the depth of myotomy. Demographics, Eckardt score, manometry results, 24-h pH monitoring, and GERD symptoms were recorded and compared between the two groups. RESULTS We studied 56 patients (32 circular myotomy and 24 full-thickness myotomy) with complete GERD evaluation. There was no significant difference between the two groups in terms of treatment success (defined as Eckardt score ≤ 3), postoperative Eckardt score, mean basal lower esophageal sphincter pressure, and 4-s integrated relaxation pressure (4sIRP). Postoperative abnormal esophageal acid exposure was found in 25 patients (44.6%). A total of 13 patients (23.2%) had GERD symptoms and 12 had esophagitis (21.4%). Clinically relevant GERD (abnormal esophageal acid exposure associated with GERD symptoms and/or esophagitis) was diagnosed in 13 patients (23.2%). Multivariate analysis revealed that full-thickness myotomy and low level of postoperative 4sIRP were predictive factors for clinically relevant GERD. CONCLUSION Efficacy and manometry are comparable between achalasia patients treated with circular or full-thickness myotomy. But patients with full-thickness myotomy and low postoperative 4sIRP have more GERD. PMID:27895430

  13. Full-thickness myotomy is associated with higher rate of postoperative gastroesophageal reflux disease.

    PubMed

    Wang, Xue-Hong; Tan, Yu-Yong; Zhu, Hong-Yi; Li, Chen-Jie; Liu, De-Liang

    2016-11-14

    To compare long-term occurrence of gastroesophageal reflux disease (GERD) between two different types of peroral endoscopic myotomy (POEM) for achalasia. We included all patients with achalasia who underwent POEM at our hospital from August 2011 to October 2012 and had complete GERD evaluation with ≥ 3 years of follow-up. They were divided into circular or full-thickness myotomy groups according to the depth of myotomy. Demographics, Eckardt score, manometry results, 24-h pH monitoring, and GERD symptoms were recorded and compared between the two groups. We studied 56 patients (32 circular myotomy and 24 full-thickness myotomy) with complete GERD evaluation. There was no significant difference between the two groups in terms of treatment success (defined as Eckardt score ≤ 3), postoperative Eckardt score, mean basal lower esophageal sphincter pressure, and 4-s integrated relaxation pressure (4sIRP). Postoperative abnormal esophageal acid exposure was found in 25 patients (44.6%). A total of 13 patients (23.2%) had GERD symptoms and 12 had esophagitis (21.4%). Clinically relevant GERD (abnormal esophageal acid exposure associated with GERD symptoms and/or esophagitis) was diagnosed in 13 patients (23.2%). Multivariate analysis revealed that full-thickness myotomy and low level of postoperative 4sIRP were predictive factors for clinically relevant GERD. Efficacy and manometry are comparable between achalasia patients treated with circular or full-thickness myotomy. But patients with full-thickness myotomy and low postoperative 4sIRP have more GERD.

  14. Preparation of Partial-Thickness Burn Wounds in Rodents Using a New Experimental Burning Device.

    PubMed

    Sakamoto, Michiharu; Morimoto, Naoki; Ogino, Shuichi; Jinno, Chizuru; Kawaguchi, Atsushi; Kawai, Katsuya; Suzuki, Shigehiko

    2016-06-01

    The manual application of hot water or hot metal to an animal's skin surface is often used to prepare burn wound models. However, manual burn creation is subject to human variability. We developed a new device that can control the temperature, time, and pressure of contact to produce precise and reproducible animal burn wounds and investigated the conditions required to prepare various burn wounds using our new device. We prepared burn wounds on F344 rats using 3 contact times 2, 4, and 10 seconds using a stamp heated to 80°C. We observed the wound-healing process macroscopically and histologically and evaluated the burn depth using a laser speckle contrast-imaging device, which evaluated the blood flow of the wound. The changes in the burned area over time, tissue perfusion of the burn wounds, histological evaluation of the burn depth by hematoxylin-eosin and azocarmine and aniline blue staining, and the epithelialization rate (the ratio of the epithelialized area to the wound length) were evaluated on histological sections. Results indicated that the burn wounds prepared with contact times of 2, 4, and 10 seconds corresponded to superficial dermal burns, deep dermal burns, and full-thickness burns, respectively. We demonstrated that partial- and full-thickness burn wounds can be precisely and reproducibly created with our new automated burning device.

  15. A Mosaicking Approach for In Vivo Thickness Mapping of the Human Tympanic Membrane Using Low Coherence Interferometry.

    PubMed

    Pande, Paritosh; Shelton, Ryan L; Monroy, Guillermo L; Nolan, Ryan M; Boppart, Stephen A

    2016-10-01

    The thickness of the human tympanic membrane (TM) is known to vary considerably across different regions of the TM. Quantitative determination of the thickness distribution and mapping of the TM is of significant importance in hearing research, particularly in mathematical modeling of middle-ear dynamics. Change in TM thickness is also associated with several middle-ear pathologies. Determination of the TM thickness distribution could therefore also enable a more comprehensive diagnosis of various otologic diseases. Despite its importance, very limited data on human TM thickness distribution, obtained almost exclusively from ex vivo samples, are available in the literature. In this study, the thickness distribution for the in vivo human TM is reported for the first time. A hand-held imaging system, which combines a low coherence interferometry (LCI) technique for single-point thickness measurement, with video-otoscopy for recording the image of the TM, was used to collect the data used in this study. Data were acquired by pointing the imaging probe over different regions of the TM, while simultaneously recording the LCI and concomitant TM surface video image data from an average of 500 locations on the TM. TM thickness distribution maps were obtained by mapping the LCI imaging sites onto an anatomically accurate wide-field image of the TM, which was generated by mosaicking the sequence of multiple small field-of-view video-otoscopy images. Descriptive statistics of the thickness measurements obtained from the different regions of the TM are presented, and the general thickness distribution trends are discussed.

  16. Retinal tissue thickness in type 1 and type 2 diabetes.

    PubMed

    Srinivasan, Sangeetha; Pritchard, Nicola; Sampson, Geoff P; Edwards, Katie; Vagenas, Dimitrios; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan

    2016-01-01

    The objective was to investigate full retinal and inner retinal thickness in individuals with type 1 and type 2 diabetes. Eighty-four individuals with type 1 diabetes (T1DM), 67 individuals with type 2 diabetes (T2DM) and 42 non-diabetic individuals (control group) were enrolled. Participants underwent full retinal thickness evaluation in the central retinal, parafoveal and perifoveal zones and in the retinal nerve fibre layer (RNFL) and ganglion cell complex (GCC), using spectral domain optical coherence tomography. As a preliminary step, the key variables of interest - age, sex, diabetic retinopathy (DR), duration of diabetes and HbA1c levels - were analysed and compared between the three groups. Full retinal thickness, RNFL and GCC thicknesses were also compared between the groups. The relationship between the type of diabetes and retinal tissue thickness was explored, adjusting for the five potential confounders. Compared to individuals with T1DM, individuals with T2DM had significantly reduced full retinal thickness in the parafovea and perifovea and reduced RNFL and GCC thickness. The mean differences were six (p = 0.020), seven (p = 0.008), six (p = 0.021) and four micrometres (p = 0.013) for the parafovea, perifovea, RNFL and GCC thicknesses, respectively. Thicknesses within the central zone (p = 0.018) and at the parafovea (p = 0.007) were significantly reduced in T2DM when compared to the control group. After adjusting for age, sex, diabetic retinopathy, duration of diabetes and HbA1c levels, the relationship between type of diabetes and retinal tissue thickness was not statistically significant (p > 0.056). Retinal tissue thickness is not significantly different between type 1 and type 2 diabetes, when adjusted for age, sex, diabetic retinopathy, duration of diabetes and HbA1c levels. © 2016 Optometry Australia.

  17. Review of Pure Endoscopic Full-Thickness Resection of the Upper Gastrointestinal Tract

    PubMed Central

    Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Masaki, Tsutomu

    2015-01-01

    Natural-orifice transluminal endoscopic surgery (NOTES) using flexible endoscopy has attracted attention as a minimally invasive surgical method that does not cause an operative wound on the body surface. However, minimizing the number of devices involved in endoscopic, compared to laparoscopic, surgeries has remained a challenge, causing endoscopic surgeries to gradually be phased out of use. If a flexible endoscopic full-thickness suturing device and a counter-traction device were developed to expand the surgical field for gastrointestinal-tract collapse, then endoscopic full-thickness resection using NOTES, which is seen as an extension of endoscopic submucosal dissection for full-thickness excision of tumors involving the gastrointestinal-tract wall, might become an extremely minimally invasive surgical method that could be used to resect only full-thickness lesions approached by the shortest distance via the mouth. It is expected that gastroenterological endoscopists will use this surgery if device development is advanced. This extremely minimally invasive surgery would have an immeasurable impact with regard to mitigating the burden on patients and reducing healthcare costs. Development of a new surgical method using a multipurpose flexible endoscope is therefore considered a socially urgent issue. PMID:26343069

  18. Dynamic histomorphometric evaluation of human fetal bone formation.

    PubMed

    Glorieux, F H; Salle, B L; Travers, R; Audra, P H

    1991-01-01

    We have evaluated dynamic and static parameters of bone formation in femoral metaphyses collected from two human fetuses at 19 weeks of gestation. Tetracycline was administered to the mother at set intervals (2-5-2 day schedule) before interruption of pregnancy. Labels were distinct and sharply linear, suggesting a well organized calcification front at this early stage of mineralization. Mineral apposition rate (MAR) was fastest (4.1 +/- 0.3 microns/d) in the periosteal (Ps) envelope, and about half that value in the endosteal envelopes (endocortical: 2.5 +/- 0.1, cancellous 2.1 +/- 0.1 microns/d). Because cellular activities may vary throughout the metaphyseal area, sections were arbitrarily separated in 0.75 mm layers starting from the growth plate. Three measured parameters decreased rapidly with increasing distance from the physis: Ps MAR: 4.9 to 2.3 microns/d, trabecular osteoid thickness: 5.9 to 1.2 microns, and cartilage volume (CgV/TV): 5.4% to 1.2%. Others did not vary significantly along the metaphysis. Comparison of several static parameters with those measured in five autopsy specimens from full-term infants showed that bone and cartilage volume, and trabecular thickness increased while osteoid thickness and parameters of resorption decreased in the second half of the gestation period. The study indicates that fetal bone matrix mineralization is already highly organized at mid-gestation, and validates the use of histomorphometry to assess bone maturation during early skeletal development.

  19. Feasibility of pure EFTR using an innovative new endoscopic suturing device: the Double-arm-bar Suturing System (with video).

    PubMed

    Mori, Hirohito; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Rafiq, Kazi; Oryu, Makoto; Fujiwara, Masao; Suzuki, Yasuyuki; Masaki, Tsutomu

    2014-02-01

    Endoscopic full-thickness resection (EFTR) requires a reliable full-thickness suturing device and an endoscopic counter-traction device to prevent the collapse of the digestive tract. The present study aimed to assess the reliability of newly developed flexible endoscopy suturing devices and the feasibility of pure EFTR. A total of 30 EFTRs were performed and allocated to three groups (N = 10 for each group). The full-thickness sutures were placed using over-the-scope clips (OTSCs), hand-sewn sutures, or the Double-arm-bar Suturing System (DBSS). Air leak tests were conducted in the three groups. The times required for the placement of one OTSC suture and single-stitch simple interrupted sutures (hand-sewn and DBSS sutures, respectively) were also compared. All 30 full-thickness sutures were completely and successfully placed. Regarding the air leak tests, the Mann-Whitney U test showed significant differences between OTSC and hand-sewn sutures (p = 0.003). There was also a significant difference between OTSC and DBSS sutures (p = 0.023). There was no significant difference between hand-sewn and DBSS sutures (p = 0.542). A significant difference was found in the suture time for single-stitch simple interrupted sutures among the OTSC, hand-sewn, and DBSS sutures. The Mann-Whitney U test revealed a significant difference between OTSC and hand-sewn sutures (p = 0.0001). There was no significant difference between OTSC and DBSS sutures (p = 0.533), while a significant difference was found between hand-sewn and DBSS sutures (p = 0.0001). Pure EFTR is feasible if the mechanical counter traction system is used to expand a small operative field and DBSS is used to make full-thickness sutures. The high safety of full-thickness resection and full-thickness suturing allows for clinical applications of this method.

  20. Full-thickness skin wound healing using autologous keratinocytes and dermal fibroblasts with fibrin: bilayered versus single-layered substitute.

    PubMed

    Idrus, Ruszymah Bt Hj; Rameli, Mohd Adha bin P; Low, Kiat Cheong; Law, Jia Xian; Chua, Kien Hui; Latiff, Mazlyzam Bin Abdul; Saim, Aminuddin Bin

    2014-04-01

    Split-skin grafting (SSG) is the gold standard treatment for full-thickness skin defects. For certain patients, however, an extensive skin lesion resulted in inadequacies of the donor site. Tissue engineering offers an alternative approach by using a very small portion of an individual's skin to harvest cells for propagation and biomaterials to support the cells for implantation. The objective of this study was to determine the effectiveness of autologous bilayered tissue-engineered skin (BTES) and single-layer tissue-engineered skin composed of only keratinocytes (SLTES-K) or fibroblasts (SLTES-F) as alternatives for full-thickness wound healing in a sheep model. Full-thickness skin biopsies were harvested from adult sheep. Isolated fibroblasts were cultured using medium Ham's F12: Dulbecco modified Eagle medium supplemented with 10% fetal bovine serum, whereas the keratinocytes were cultured using Define Keratinocytes Serum Free Medium. The BTES, SLTES-K, and SLTES-F were constructed using autologous fibrin as a biomaterial. Eight full-thickness wounds were created on the dorsum of the body of the sheep. On 4 wounds, polyvinyl chloride rings were used as chambers to prevent cell migration at the edge. The wounds were observed at days 7, 14, and 21. After 3 weeks of implantation, the sheep were euthanized and the skins were harvested. The excised tissues were fixed in formalin for histological examination via hematoxylin-eosin, Masson trichrome, and elastin van Gieson staining. The results showed that BTES, SLTES-K, and SLTES-F promote wound healing in nonchambered and chambered wounds, and BTES demonstrated the best healing potential. In conclusion, BTES proved to be an effective tissue-engineered construct that can promote the healing of full-thickness skin lesions. With the support of further clinical trials, this procedure could be an alternative to SSG for patients with partial- and full-thickness burns.

  1. Wound contraction effects and antibacterial properties of Tualang honey on full-thickness burn wounds in rats in comparison to hydrofibre

    PubMed Central

    2010-01-01

    Background Full-thickness burn wounds require excision and skin grafting. Multiple surgical procedures are inevitable in managing moderate to severe full-thickness burns. Wound bed preparations prior to surgery are necessary in order to prevent wound infection and promote wound healing. Honey can be used to treat burn wounds. However, not all the honey is the same. This study aims to evaluate the wound contraction and antibacterial properties of locally-produced Tualang honey on managing full-thickness burn wounds in vivo. Methods Thirty-six female Sprague Dawley rats were randomly divided into three groups. Under anaesthesia, three full-thickness burn wounds were created on the dorsum of the rats. The full-thickness burn wounds were inoculated with a specific organism (104), namely Pseudomonas aeruginosa (n = 12), Klebsiella pneumoniae (n = 12), or Acinetobacter baumannii (n = 12). The three burn wounds were dressed with Tualang honey, hydrofibre and hydrofibre silver respectively. Swab samples were obtained every 3 days (day 3, 6, 9, 12, 15, 18 and 21) for quantitative and semi-quantitative microbiological analyses. Clinical assessments, including observations concerning the appearance and wound size, were measured at the same time. Results There was a rapid 32.26% reduction in wound size by day 6 (p = 0.008) in the Tualang honey-treated wounds, and 49.27% by day 15 (p = 0.005). The wounds remained smaller by day 18 (p < 0.032). Tualang honey-treated rats demonstrated a reduction in bacterial growth in Pseudomonas aeruginosa inoculated wounds (p = 0.005). However, hydrofibre silver and hydrofibre-treated wounds are superior to honey-treated wounds with Acinetobacter baumannii (p = 0.035). There was no statistical significant of antibacterial property in Klebsiella pneumonia inoculated wounds. Conclusions Tualang honey has better results with regards to its control of Pseudomonas aeruginosa and its wound contraction effects on full-thickness burn wound in vivo. PMID:20815896

  2. Skin resurfacing in a circumferential full thickness burn to the penis: lessons learnt.

    PubMed

    Jabir, Shehab; Frew, Quentin; Thompson, Richard; Dziewulski, Peter

    2013-08-13

    A circumferential full-thickness burn to the penis is a rarely encountered injury. However, when it does occur, it proves a management challenge to the plastic and burns surgeon in terms of reconstruction. This is due to the need of not only regaining adequate function of the organ, but also because of the need for a pleasing aesthetic outcome. Split-skin grafts have been utilised successfully to resurface full thickness burns of the penis and have given good results. Yet the success of split-skin grafts, especially those applied to an anatomically challenging region of the body such as the penis, depends on a number of carefully thought-out steps. We discuss the case of a circumferential full-thickness burn to the penis which was treated with split-skin grafting and highlight important pitfalls that the plastic and burns surgeon need to be aware of to ensure a successful outcome.

  3. Skin resurfacing in a circumferential full thickness burn to the penis: lessons learnt

    PubMed Central

    Jabir, Shehab; Frew, Quentin; Thompson, Richard; Dziewulski, Peter

    2013-01-01

    A circumferential full-thickness burn to the penis is a rarely encountered injury. However, when it does occur, it proves a management challenge to the plastic and burns surgeon in terms of reconstruction. This is due to the need of not only regaining adequate function of the organ, but also because of the need for a pleasing aesthetic outcome. Split-skin grafts have been utilised successfully to resurface full thickness burns of the penis and have given good results. Yet the success of split-skin grafts, especially those applied to an anatomically challenging region of the body such as the penis, depends on a number of carefully thought-out steps. We discuss the case of a circumferential full-thickness burn to the penis which was treated with split-skin grafting and highlight important pitfalls that the plastic and burns surgeon need to be aware of to ensure a successful outcome. PMID:23946511

  4. Fluorescein permeability and electrical resistance of human skin during low frequency ultrasound application.

    PubMed

    Cancel, Limary M; Tarbell, John M; Ben-Jebria, Abdellaziz

    2004-09-01

    Transdermal drug delivery offers an alternative to injections and oral medication but is limited by the low skin permeability of most drugs. The use of low-frequency ultrasound over long periods of time, typically over an hour, has been shown to enhance skin permeability, a phenomenon referred to as sonophoresis. In this study, we investigated the effects of short time sonication of human skin at 20 kHz and at variable intensities and duty cycles on the dynamics of fluorescein transport across the skin (permeability) as well as the changes in the skin's structural integrity (electrical resistance). We found that a short application of ultrasound enhanced the transport of fluorescein across human skin by a factor in the range of 2-9 for full thickness skin samples and by a factor in the range of 2-28 000 for heat-stripped stratum corneum samples (however, samples with very high (10(3)) enhancement were likely to have been damaged by ultrasound). The electrical resistance of the skin decreased by an average of 20% for full thickness samples and 58% for stratum corneum samples. Increasing the duty cycle from 10 to 60% caused a significant increase in permeability enhancement from 2.3 to 9.1, and an increase in intensity from 8 to 23 mW cm(-2) induced a significant increase in permeability enhancement from 2 to 7.4, indicating a clear dependence of the permeability on both duty cycle and intensity. The increase in solute flux upon ultrasound exposure was immediate, demonstrating for the first time the fast response dynamics of sonophoretic enhancement. In addition, a quantitative analysis of the thermal and convective dispersion effects associated with ultrasound application showed that each contributes significantly to the overall permeability enhancement observed.

  5. Regulation of Hsp27 and Hsp70 expression in human and mouse skin construct models by caveolae following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, Adrienne T.; Hayden, Patrick J.; Casillas, Robert P.

    Dermal exposure to the vesicant sulfur mustard causes marked inflammation and tissue damage. Basal keratinocytes appear to be a major target of sulfur mustard. In the present studies, mechanisms mediating skin toxicity were examined using a mouse skin construct model and a full-thickness human skin equivalent (EpiDerm-FT{sup TM}). In both systems, administration of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide (CEES, 100-1000 {mu}M) at the air surface induced mRNA and protein expression of heat shock proteins 27 and 70 (Hsp27 and Hsp70). CEES treatment also resulted in increased expression of caveolin-1, the major structural component of caveolae. Immunohistochemistry revealedmore » that Hsp27, Hsp70 and caveolin-1 were localized in basal and suprabasal layers of the epidermis. Caveolin-1 was also detected in fibroblasts in the dermal component of the full thickness human skin equivalent. Western blot analysis of caveolar membrane fractions isolated by sucrose density centrifugation demonstrated that Hsp27 and Hsp70 were localized in caveolae. Treatment of mouse keratinocytes with filipin III or methyl-{beta}-cyclodextrin, which disrupt caveolar structure, markedly suppressed CEES-induced Hsp27 and Hsp70 mRNA and protein expression. CEES treatment is known to activate JNK and p38 MAP kinases; in mouse keratinocytes, inhibition of these enzymes suppressed CEES-induced expression of Hsp27 and Hsp70. These data suggest that MAP kinases regulate Hsp 27 and Hsp70; moreover, caveolae-mediated regulation of heat shock protein expression may be important in the pathophysiology of vesicant-induced skin toxicity.« less

  6. Depth-Dependent Transverse Shear Properties of the Human Corneal Stroma

    PubMed Central

    Petsche, Steven J.; Chernyak, Dimitri; Martiz, Jaime; Levenston, Marc E.

    2012-01-01

    Purpose. To measure the transverse shear modulus of the human corneal stroma and its profile through the depth by mechanical testing, and to assess the validity of the hypothesis that the shear modulus will be greater in the anterior third due to increased interweaving of lamellae. Methods. Torsional rheometry was used to measure the transverse shear properties of 6 mm diameter buttons of matched human cadaver cornea pairs. One cornea from each pair was cut into thirds through the thickness with a femtosecond laser and each stromal third was tested individually. The remaining intact corneas were tested to measure full stroma shear modulus. The shear modulus from a 1% shear strain oscillatory test was measured at various levels of axial compression for all samples. Results. After controlling for axial compression, the transverse shear moduli of isolated anterior layers were significantly higher than central and posterior layers. Mean modulus values at 0% axial strain were 7.71 ± 6.34 kPa in the anterior, 1.99 ± 0.45 kPa in the center, 1.31 ± 1.01 kPa in the posterior, and 9.48 ± 2.92 kPa for full thickness samples. A mean equilibrium compressive modulus of 38.7 ± 8.6 kPa at 0% axial strain was calculated from axial compression measured during the shear tests. Conclusions. Transverse shear moduli are two to three orders of magnitude lower than tensile moduli reported in the literature. The profile of shear moduli through the depth displayed a significant increase from posterior to anterior. This gradient supports the hypothesis and corresponds to the gradient of interwoven lamellae seen in imaging of stromal cross-sections. PMID:22205608

  7. Regulation of Hsp27 and Hsp70 expression in human and mouse skin construct models by caveolae following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide

    PubMed Central

    Black, Adrienne T.; Hayden, Patrick J.; Casillas, Robert P.; Heck, Diane E.; Gerecke, Donald R.; Sinko, Patrick J.; Laskin, Debra L.; Laskin, Jeffrey D.

    2012-01-01

    Dermal exposure to the vesicant sulfur mustard causes marked inflammation and tissue damage. Basal keratinocytes appear to be a major target of sulfur mustard. In the present studies, mechanisms mediating skin toxicity were examined using a mouse skin construct model and a full-thickness human skin equivalent (EpiDerm-FTTM). In both systems, administration of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide (CEES, 100–1000 µM) at the air surface induced mRNA and protein expression of heat shock proteins 27 and 70 (Hsp27 and Hsp70). CEES treatment also resulted in increased expression of caveolin-1, the major structural component of caveolae. Immunohistochemistry revealed that Hsp27, Hsp70 and caveolin-1 were localized in basal and suprabasal layers of the epidermis. Caveolin-1 was also detected in fibroblasts in the dermal component of the full thickness human skin equivalent. Western blot analysis of caveolar membrane fractions isolated by sucrose density centrifugation demonstrated that Hsp27 and Hsp70 were localized in caveolae. Treatment of mouse keratinocytes with filipin III or methyl-β-cyclodextrin, which disrupt caveolar structure, markedly suppressed CEES-induced Hsp27 and Hsp70 mRNA and protein expression. CEES treatment is known to activate JNK and p38 MAP kinases; in mouse keratinocytes, inhibition of these enzymes suppressed CEES-induced expression of Hsp27 and Hsp70. These data suggest that MAP kinases regulate Hsp 27 and Hsp70; moreover, caveolae-mediated regulation of heat shock protein expression may be important in the pathophysiology of vesicant-induced skin toxicity. PMID:21457723

  8. Regulation of Hsp27 and Hsp70 expression in human and mouse skin construct models by caveolae following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide.

    PubMed

    Black, Adrienne T; Hayden, Patrick J; Casillas, Robert P; Heck, Diane E; Gerecke, Donald R; Sinko, Patrick J; Laskin, Debra L; Laskin, Jeffrey D

    2011-06-01

    Dermal exposure to the vesicant sulfur mustard causes marked inflammation and tissue damage. Basal keratinocytes appear to be a major target of sulfur mustard. In the present studies, mechanisms mediating skin toxicity were examined using a mouse skin construct model and a full-thickness human skin equivalent (EpiDerm-FT™). In both systems, administration of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide (CEES, 100-1000μM) at the air surface induced mRNA and protein expression of heat shock proteins 27 and 70 (Hsp27 and Hsp70). CEES treatment also resulted in increased expression of caveolin-1, the major structural component of caveolae. Immunohistochemistry revealed that Hsp27, Hsp70 and caveolin-1 were localized in basal and suprabasal layers of the epidermis. Caveolin-1 was also detected in fibroblasts in the dermal component of the full thickness human skin equivalent. Western blot analysis of caveolar membrane fractions isolated by sucrose density centrifugation demonstrated that Hsp27 and Hsp70 were localized in caveolae. Treatment of mouse keratinocytes with filipin III or methyl-β-cyclodextrin, which disrupt caveolar structure, markedly suppressed CEES-induced Hsp27 and Hsp70 mRNA and protein expression. CEES treatment is known to activate JNK and p38 MAP kinases; in mouse keratinocytes, inhibition of these enzymes suppressed CEES-induced expression of Hsp27 and Hsp70. These data suggest that MAP kinases regulate Hsp 27 and Hsp70; moreover, caveolae-mediated regulation of heat shock protein expression may be important in the pathophysiology of vesicant-induced skin toxicity. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. THE ASSOCIATION OF EPIRETINAL MEMBRANE WITH MACULAR HOLE FORMATION AFTER RHEGMATOGENOUS RETINAL DETACHMENT REPAIR.

    PubMed

    Khurana, Rahul N; Wykoff, Charles C; Bansal, Alok S; Akiyama, Kunihiko; Palmer, James D; Chen, Eric; Chang, Louis K; Major, James C; Wu, Chengqing; Wang, Rui; Croft, Daniel E; Wong, Tien P

    2017-06-01

    To describe the clinical and optical coherence tomography findings associated with the development of full-thickness macular holes after rhegmatogenous retinal detachment (RRD) repair. Retrospective, interventional case series. All patients who developed full-thickness macular holes after successful RRD repair from 3 clinical practices were reviewed. All cases of combined/simultaneous full-thickness macular hole and RRD were excluded. The main outcome measure was the presence of an epiretinal membrane at time of diagnosis of macular hole. Twenty-five full-thickness macular holes were diagnosed after successful retinal detachment repair. Surgical approach to RRD repair included pneumatic retinopexy (6, 24%), scleral buckle alone (5, 20%), pars plana vitrectomy only (8, 32%), and combined scleral buckle and pars plana vitrectomy (6, 24%). The preceding RRD involved the macula in 19 patients (76%) before the formation of the macular hole. The median time to full-thickness macular hole diagnosis after RRD repair was 63 days (range, 4-4,080 days). An epiretinal membrane was present in all 25 (100%) macular holes. Two macular holes (8%) spontaneously closed, whereas the other 23 (92%) were successfully closed with a single surgical procedure. Mean visual acuity improved by approximately 5 lines to 20/72 (range, 20/20 to counting fingers at 1 foot) from 20/240 (range, 20/30 to hand motions) after macular hole repair (P < 0.0001). Full-thickness macular hole formation can occur after all types of RRD repair and is associated with an epiretinal membrane. The epiretinal membrane may play a role in the pathogenesis of secondary macular hole formation after RRD repair.

  10. A Novel Collagen-Gelatin Scaffold for the Treatment of Deep Dermal Wounds-An Evaluation in a Minipig Model.

    PubMed

    Held, Manuel; Rahmanian-Schwarz, Afshin; Schiefer, Jennifer; Rath, Rebekka; Werner, Jan-Ole; Rahmanian, Shahab; Schaller, Hans-Eberhard; Petersen, Wiebke

    2016-06-01

    Today, autologous skin transplantation is frequently used for full-thickness skin defects. There is still a high demand for new wound-healing products to replace autologous skin transplantation. In this context, the effect of a new collagen-gelatin scaffold on full-thickness skin defects was evaluated. Four full-thickness skin defects were created surgically on the dorsum of 6 Göttingen minipigs. Three wounds were randomly treated with a novel collagen-gelatin scaffold in different thicknesses, whereas the fourth wound was left untreated and served as a control wound. During the experimental period of 21 days, a close-up photographic documentation was performed. Afterwards, the areas of the initial wounds were excised and examined histologically. The systematic evaluation of 24 wounds showed that treatment with the new collagen-gelatin scaffold led to an accelerated wound repair of 1.1 days. Compared to control wounds, it also demonstrated improved skin quality in regard to epidermal thickness. The new collagen-gelatin scaffold supports and accelerates dermal wound repair compared to untreated control wounds. Nevertheless, wound treatment with the scaffold was only performed on the first day. In further studies, the impact of multiple scaffold applications on full-thickness skin defects should be investigated.

  11. Distribution, Complications, and Outcome of Footpad Injuries in Pet and Military Working Dogs.

    PubMed

    Hansen, Lane A; Hazenfield, Kurt M; Olea-Popelka, Francisco; Smeak, Dan D

    2015-01-01

    This study reports the findings of 120 traumatic pad injuries in pet and military dogs. Most dogs (68%) presented with a laceration to a thoracic limb footpad, and one-third of dogs were middle-aged castrated males. Metacarpal pads were most commonly injured. Short-term complications were noted in 27% of dogs. No long-term complications were identified. No disability from pad injury was present at the completion of healing. Concurrent injuries to adjacent structures were uncommon and did not affect outcome. Dogs with full-thickness pad lacerations were at greater risk for major short-term complications compared to dogs with partial-thickness pad lacerations (odds ratio, 7.27; P = .001). Military working dogs with full-thickness pad lacerations were at greater risk for major short-term complications than pet dogs with a similar injury. When major complications developed in dogs with full-thickness pad injuries, time to final healing was significantly longer (by a median of 12 days). The partial-thickness pad lesions healed uneventfully regardless of whether they were bandaged, surgically repaired, or left to heal by second intention. Suture repair and bandaging of full-thickness lesions could not be shown to either decrease the risk for complications or improve healing. Future work should focus on establishing standards for footpad treatment to reduce complications.

  12. Development of the mechanical properties of engineered skin substitutes after grafting to full-thickness wounds.

    PubMed

    Sander, Edward A; Lynch, Kaari A; Boyce, Steven T

    2014-05-01

    Engineered skin substitutes (ESSs) have been reported to close full-thickness burn wounds but are subject to loss from mechanical shear due to their deficiencies in tensile strength and elasticity. Hypothetically, if the mechanical properties of ESS matched those of native skin, losses due to shear or fracture could be reduced. To consider modifications of the composition of ESS to improve homology with native skin, biomechanical analyses of the current composition of ESS were performed. ESSs consist of a degradable biopolymer scaffold of type I collagen and chondroitin-sulfate (CGS) that is populated sequentially with cultured human dermal fibroblasts (hF) and epidermal keratinocytes (hK). In the current study, the hydrated biopolymer scaffold (CGS), the scaffold populated with hF dermal skin substitute (DSS), or the complete ESS were evaluated mechanically for linear stiffness (N/mm), ultimate tensile load at failure (N), maximum extension at failure (mm), and energy absorbed up to the point of failure (N-mm). These biomechanical end points were also used to evaluate ESS at six weeks after grafting to full-thickness skin wounds in athymic mice and compared to murine autograft or excised murine skin. The data showed statistically significant differences (p <0.05) between ESS in vitro and after grafting for all four structural properties. Grafted ESS differed statistically from murine autograft with respect to maximum extension at failure, and from intact murine skin with respect to linear stiffness and maximum extension. These results demonstrate rapid changes in mechanical properties of ESS after grafting that are comparable to murine autograft. These values provide instruction for improvement of the biomechanical properties of ESS in vitro that may reduce clinical morbidity from graft loss.

  13. Strength and deformation characteristics of pavements

    NASA Astrophysics Data System (ADS)

    Shook, J. F.; Kallas, B. F.; McCullough, B. F.; Taute, A.; Rada, G.; Witczak, M. W.; Heisey, J. S.; Stokoe, K. H.; Meyer, A. H.; Huffman, M. S.

    The Colorado experimental base project was a full-scale field experment constructed with various thicknesses of two full depth hot mix sand asphalt beans, one full depth asphalt concrete base, and one thickness of a standard design with untreated base and subbase layers. Relative thicknesses of one asphalt concrete base, two hot mix sand asphalt bases, and one standard design with untreated base and subbase required to give an equal level of pavement performance were determined. Certain measured properties of the pavement and the pavement components were related to observed levels of performance by using both empirical and theoretical models for pavement behavior.

  14. [Endoscopic full-thickness resection].

    PubMed

    Meier, B; Schmidt, A; Caca, K

    2016-08-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.

  15. Human skin absorption of Bis-2-(chloroethyl)sulphide (sulphur mustard) in vitro.

    PubMed

    Chilcott, R P; Jenner, J; Carrick, W; Hotchkiss, S A; Rice, P

    2000-01-01

    The purpose of this study was to measure the absorption and intra-epidermal fate of 35S-radiolabelled sulphur mustard (35SM) in human breast skin in vitro. Skin (full-thickness or heat-separated epidermis) was placed into static diffusion cells and was exposed to droplets of liquid 35SM or saturated 35SM vapour. Amounts of 35SM penetrating the skin were measured from which skin absorption rates were calculated. Unbound radiolabel was washed from the surface, extracted from the skin and analysed to determine the identity of the radiolabelled species in order to measure the extent of hydrolysis of sulphur mustard. Penetration rates of liquid 35SM measured in vitro (71-294 microg cm(-2) h(-1)) were in agreement with those measured previously in vivo using human volunteers (60-240 microg cm(-2) h(-1)). Rates of liquid 35SM skin absorption under occluded, infinite dose conditions were highest through heat-separated epidermal membranes (294+/-58 microg cm(-2) h(-1)) and lowest through full-thickness skin (71+/-14 microg cm(-2) h(-1)). Fluxes of saturated 35SM vapour (110+/-75 microg cm(-2) h(-1)) through heat-separated membranes were similar to those previously measured through human forearm skin in vivo (162 microg cm(-2) h(-1)). Although hydrolysis of 35SM did occur, both on the surface and within the skin, it accounted for only a small percentage of the total applied dose (<2.7+/-1.2%). The difference in total amount of liquid 35SM penetrated between occluded and unoccluded conditions in vitro (79+/-14%) was similar to that lost as vapour from unoccluded skin in vivo (80%). A substantial reservoir of 35SM (14-36% of the applied dose) was measured within heat-separated epidermal membranes for up to 24 h which may have significant implications for the management of personnel exposed to sulphur mustard.

  16. Penile Inversion Vaginoplasty with or without Additional Full-Thickness Skin Graft: To Graft or Not to Graft?

    PubMed

    Buncamper, Marlon E; van der Sluis, Wouter B; de Vries, Max; Witte, Birgit I; Bouman, Mark-Bram; Mullender, Margriet G

    2017-03-01

    Penile inversion vaginoplasty is considered to be the gold standard for gender reassignment surgery in transgender women. The use of additional full-thickness skin graft as neovaginal lining is controversial. Some believe that having extra penile skin for the vulva gives better aesthetic results. Others believe that it gives inferior functional results because of insensitivity and skin graft contraction. Transgender women undergoing penile inversion vaginoplasty were studied prospectively. The option to add full-thickness skin graft is offered in patients where the penile skin length lies between 7 and 12 cm. Neovaginal depth was measured at surgery and during follow-up (3, 13, 26, and 52 weeks postoperatively). Satisfaction with the aesthetic result, neovaginal depth, and dilation regimen during follow-up were recorded. Satisfaction, sexual function, and genital self-image were assessed using questionnaires. A total of 100 patients were included (32 with and 68 without additional full-thickness skin graft). Patient-reported aesthetic outcome, overall satisfaction with the neovagina, sexual function, and genital self-image were not significantly associated with surgical technique. The mean intraoperative neovaginal depth was 13.8 ± 1.4 cm. After 1 year, this was 11.5 ± 2.5 cm. The largest decline (-15 percent) in depth is observed in the first 3 postoperative weeks (p < 0.01). The authors can confirm neither of the suggested arguments, for or against full-thickness skin graft use, in penile inversion vaginoplasty. The additional use of full-thickness skin graft does not influence neovaginal shrinkage, nor does it affect the patient- and physician-reported aesthetic or functional outcome. Therapeutic, IV.

  17. Delaminated rotator cuff tear: extension of delamination and cuff integrity after arthroscopic rotator cuff repair.

    PubMed

    Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John

    2015-05-01

    The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Comparison of a new hydro-surgical technique to traditional methods for the preparation of full-thickness skin grafts from canine cadaveric skin and report of a single clinical case.

    PubMed

    Townsend, F I; Ralphs, S C; Coronado, G; Sweet, D C; Ward, J; Bloch, C P

    2012-01-01

    To compare the hydro-surgical technique to traditional techniques for removal of subcutaneous tissue in the preparation of full-thickness skin grafts. Ex vivo experimental study and a single clinical case report. Four canine cadavers and a single clinical case. Four sections of skin were harvested from the lateral flank of recently euthanatized dogs. Traditional preparation methods used included both a blade or scissors technique, each of which were compared to the hydro-surgical technique individually. Preparation methods were compared based on length of time for removal of the subcutaneous tissue from the graft, histologic grading, and measurable thickness as compared to an untreated sample. The hydro-surgical technique had the shortest skin graft preparation time as compared to traditional techniques (p = 0.002). There was no significant difference in the histological grading or measurable subcutaneous thickness between skin specimens. The hydro-surgical technique provides a rapid, effective debridement of subcutaneous tissue in the preparation of full-thickness skin grafts. There were not any significant changes in histological grade and subcutaneous tissue remaining among all treatment types. Additionally the hydro-surgical technique was successfully used to prepare a full-thickness meshed free skin graft in the reconstruction of a traumatic medial tarsal wound in a dog.

  19. Live cell refractometry using Hilbert phase microscopy and confocal reflectance microscopy.

    PubMed

    Lue, Niyom; Choi, Wonshik; Popescu, Gabriel; Yaqoob, Zahid; Badizadegan, Kamran; Dasari, Ramachandra R; Feld, Michael S

    2009-11-26

    Quantitative chemical analysis has served as a useful tool for understanding cellular metabolisms in biology. Among many physical properties used in chemical analysis, refractive index in particular has provided molecular concentration that is an important indicator for biological activities. In this report, we present a method of extracting full-field refractive index maps of live cells in their native states. We first record full-field optical thickness maps of living cells by Hilbert phase microscopy and then acquire physical thickness maps of the same cells using a custom-built confocal reflectance microscope. Full-field and axially averaged refractive index maps are acquired from the ratio of optical thickness to physical thickness. The accuracy of the axially averaged index measurement is 0.002. This approach can provide novel biological assays of label-free living cells in situ.

  20. Live Cell Refractometry Using Hilbert Phase Microscopy and Confocal Reflectance Microscopy†

    PubMed Central

    Lue, Niyom; Choi, Wonshik; Popescu, Gabriel; Yaqoob, Zahid; Badizadegan, Kamran; Dasari, Ramachandra R.; Feld, Michael S.

    2010-01-01

    Quantitative chemical analysis has served as a useful tool for understanding cellular metabolisms in biology. Among many physical properties used in chemical analysis, refractive index in particular has provided molecular concentration that is an important indicator for biological activities. In this report, we present a method of extracting full-field refractive index maps of live cells in their native states. We first record full-field optical thickness maps of living cells by Hilbert phase microscopy and then acquire physical thickness maps of the same cells using a custom-built confocal reflectance microscope. Full-field and axially averaged refractive index maps are acquired from the ratio of optical thickness to physical thickness. The accuracy of the axially averaged index measurement is 0.002. This approach can provide novel biological assays of label-free living cells in situ. PMID:19803506

  1. Learning from regeneration research organisms: The circuitous road to scar free wound healing

    PubMed Central

    Erickson, Jami R.; Echeverri, Karen

    2018-01-01

    The skin is the largest organ in the body and plays multiple essential roles ranging from regulating temperature, preventing infection and ultimately defining who we are physically. It is a highly dynamic organ that constantly replaces the outermost cells throughout life. However, when faced with a major injury, human skin cannot restore a significant lesion to its original functionality, instead a reparative scar is formed. In contrast to this, many other species have the unique ability to regenerate full thickness skin without formation of scar tissue. Here we review recent advances in the field that shed light on how the skin cells in regenerative species react to injury to prevent scar formation versus scar forming humans. PMID:29179946

  2. Elephantiasis Nostras Verrucosa. Excision with full-thickness skin grafting of the penis, scrotum, and perineal area.

    PubMed

    Judge, Nathan; Kilic, Ali

    2016-11-13

    Elephantiasis nostras verrucosa is a rare cutaneous complication of chronic lymphatic obstruction. It is most commonly caused by bacterial infection, trauma, neoplasia, obesity, and venous stasis. In this report, we describe a case of elephantiasis nostras verrucosa involving the scrotum and perineal area in a 32-year-old. The lesions were excised, and full-thickness skin grafting of the penis, scrotum, and perineal skin was performed. This case demonstrates the efficacy of excision with full-thickness skin grafting of the penis, scrotum, and perineal area in a patient with elephantiasis nostras verrucosa confined to the scrotum and perineal region.

  3. [The cutaneous groin flap for coverage of a full-thickness abdominal wall defect].

    PubMed

    Doebler, O; Spierer, R

    2010-08-01

    A full-thickness defect of the abdominal wall is rare and may occur as a complication of extended abdominal surgery procedures. We report about a 69-year-old patient who was presented to our department with a full-thickness abdominal wall defect and a fully exposed collagen-mesh for reconstructive wound closure. 13 operations with resections of necrotic parts of the abdominal wall were performed following a complicated intraabdominal infection. After debridement and mesh explantation, closure of the remaining defect of the lower abdominal region was achieved by a cutaneous groin flap. Georg Thieme Verlag KG Stuttgart New York.

  4. Three-dimensional bioprinting of thick vascularized tissues

    NASA Astrophysics Data System (ADS)

    Kolesky, David B.; Homan, Kimberly A.; Skylar-Scott, Mark A.; Lewis, Jennifer A.

    2016-03-01

    The advancement of tissue and, ultimately, organ engineering requires the ability to pattern human tissues composed of cells, extracellular matrix, and vasculature with controlled microenvironments that can be sustained over prolonged time periods. To date, bioprinting methods have yielded thin tissues that only survive for short durations. To improve their physiological relevance, we report a method for bioprinting 3D cell-laden, vascularized tissues that exceed 1 cm in thickness and can be perfused on chip for long time periods (>6 wk). Specifically, we integrate parenchyma, stroma, and endothelium into a single thick tissue by coprinting multiple inks composed of human mesenchymal stem cells (hMSCs) and human neonatal dermal fibroblasts (hNDFs) within a customized extracellular matrix alongside embedded vasculature, which is subsequently lined with human umbilical vein endothelial cells (HUVECs). These thick vascularized tissues are actively perfused with growth factors to differentiate hMSCs toward an osteogenic lineage in situ. This longitudinal study of emergent biological phenomena in complex microenvironments represents a foundational step in human tissue generation.

  5. Status of the contralateral rotator cuff in patients undergoing rotator cuff repair.

    PubMed

    Ro, Kyung-Han; Park, Jong-Hoon; Lee, Soon-Hyuck; Song, Dong-Ik; Jeong, Ha-Joon; Jeong, Woong-Kyo

    2015-05-01

    Although the prevalence of rotator cuff tear (RCT) in the general population has been analyzed, little information is available on the status of the opposite-side rotator cuff in patients who have undergone arthroscopic rotator cuff repair. To identify the characteristics of the contralateral shoulder and to identify factors associated with RCT of the contralateral shoulder in patients who underwent surgery for symptomatic RCT. The hypothesis was that the prevalence of RCT in the contralateral shoulder would be higher in patients with increasingly larger cuff tears requiring surgical intervention. Case series; Level of evidence, 4. The study cohort consisted of 140 patients with RCT who underwent arthroscopic rotator cuff repair. Opposite-shoulder rotator cuff tendons of all patients were evaluated by ultrasonography. Demographic information and factors related to contralateral RCT were investigated, and risk factors associated with contralateral RCT were assessed. Of the 140 patients who underwent arthroscopic rotator cuff repair, 54 (38.6%) had an RCT of the contralateral shoulder. Of 51 patients with partial-thickness and small-sized full-thickness tears of the operated shoulder, 35 (68.6%) had no tears; 14 (27.5%) had partial-thickness tears; and 2 (3.9%) had small-sized full-thickness tears of the contralateral shoulder. Of 75 patients with medium-sized full-thickness tears, 43 (57.3%) had no tears; 12 (16%) had partial-thickness tears; and 20 (26.7%) had full-thickness tears of the contralateral shoulder. Of 14 patients with large to massive full-thickness tears, 8 (57.1%) had no tears; 1 (7.1%) had a partial-thickness tear; and 5 (35.7%) had full-thickness tears of the contralateral shoulder. The prevalence of RCT of the contralateral shoulder differed significantly among groups classified by tear size (P=.007). The mean American Shoulder and Elbow Surgeons score was significantly lower in the RCT than in the nontear group (55.8±16.9 vs 61.6±13.3; P=.03). Of 29 subjects with symptomatic tears involving the nondominant arm, 17 (58.6%) had contralateral asymptomatic RCT, compared with 37 of 111 (33.3%) subjects with symptomatic tears involving the dominant arm (P=.007). The prevalence of RCT of the contralateral asymptomatic shoulder tends to be higher in patients with more symptomatic RCT on one side, in patients with medium-sized or larger RCT in the operated shoulder, and in patients with symptomatic RCT in the nondominant arm. © 2015 The Author(s).

  6. A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft.

    PubMed

    Lim, Hyoseob; Han, Dae Hee; Lee, Il Jae; Park, Myong Chul

    2014-03-01

    Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.

  7. [Late results following surgical correction of syndactyly and symbrachydactyly].

    PubMed

    Deutinger, M; Mandl, H; Frey, M; Holle, J; Freilinger, G

    1989-02-01

    Growth and the type of surgical treatment of the hand play an important role in the results of surgery in children. 29 patients have been operated on because of syndactyly and symbrachydactyly and were controlled. The following parameters were assessed: kind of incision and skin graft, functional results, x-ray to examine the skeleton and the depth of the commissure, colour of the skin graft and use of the hand. After operation of syndactyly all patients were able to use their hands normally, although full extend of flexion and extension was achieved only in 20 of 22 hands. In 5 divided pairs of fingers there was recurrence of syndactyly. In all cases except one, a split thickness skin graft has been used. After operative treatment of symbrachydactyly and complex syndactyly, full extent of flexion was achieved in 13 of 19 hands, in 6 hands the range of flexion was incomplete because of skeleton abnormalities. Recurrence occurred in 9 divided pairs of fingers; in 7 cases, a split thickness skin graft had been used. Despite this, all patients were able to use their hands normally. The use of split thickness skin grafts resulted in a 60% recurrence rate, whereas the use of full thickness skin graft led merely to 7.5% recurrence rate. Our results show the advantage of the full thickness skin graft. As a consequence, full thickness skin graft should be used in all cases. Furthermore, the operation should be performed at an early age, if fingers of unequal length have to be separated. Zig-zag incision should be used in all cases.

  8. The role of resveratrol on full - Thickness uterine wound healing in rats.

    PubMed

    Sayin, Oya; Micili, Serap Cilaker; Goker, Asli; Kamaci, Gonca; Ergur, Bekir Ugur; Yilmaz, Osman; Guner Akdogan, Gul

    2017-10-01

    Healing of the uterus after cesarean section and myomectomy operation is clinically important. In this study, we aimed to investigate the effects of resveratrol (3,5,4'-o-trihydroxystilbene) on the wound healing process of the uterus in rats treated with resveratrol following full thickness injury of the uterus. Twenty-one female wistar albino rats were divided randomly into three groups (1) control group with no intervention (2) injury group with uterine full thickness injury (3) resveratrol group with uterine full thickness injury and treated with resveratrol. Resveratrol was injected by oral gavage at the doses of 0.5 mg/kg/day for 30 days following uterine full thickness injury. Vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF) distributions were assessed using the immunohistochemical methods in tissue and ELISA methods in the tissue homogenate. Glutathione peroxidase (GPx) and superoxide dismutase (SOD) activities were evaluated with colorimetric method and malondialdehyde (MDA) levels also were measured using high performance liquid chromatography in the tissue homogenate. The effects of resveratrol on the uterine histology also were evaluated histologically with the light microscopy. Histological evaluation and immunohistochemical evaluations showed that treatment with a resveratrol significantly increased the thickness of the uterine wall and VEGF expression and decreased expression PDGF during wound healing. Biochemically, GPx and SOD activities were increased significantly after treatment with resveratrol. Additionally, resveratrol administration decreased MDA levels. These results showed that the antioxidant effects of resveratrol has been shown to have a positive influence on wound healing of the uterus. Copyright © 2017. Published by Elsevier B.V.

  9. Autologous chondrocyte implantation: Is it likely to become a saviour of large-sized and full-thickness cartilage defect in young adult knee?

    PubMed

    Zhang, Chi; Cai, You-Zhi; Lin, Xiang-Jin

    2016-05-01

    A literature review of the first-, second- and third-generation autologous chondrocyte implantation (ACI) technique for the treatment of large-sized (>4 cm(2)) and full-thickness knee cartilage defects in young adults was conducted, examining the current literature on features, clinical scores, complications, magnetic resonance image (MRI) and histological outcomes, rehabilitation and cost-effectiveness. A literature review was carried out in the main medical databases to evaluate the several studies concerning ACI treatment of large-sized and full-thickness knee cartilage defects in young adults. ACI technique has been shown to relieve symptoms and improve functional assessment in large-sized (>4 cm(2)) and full-thickness knee articular cartilage defect of young adults in short- and medium-term follow-up. Besides, low level of evidence demonstrated its efficiency and durability at long-term follow-up after implantation. Furthermore, MRI and histological evaluations provided the evidence that graft can return back to the previous nearly normal cartilage via ACI techniques. Clinical outcomes tend to be similar in different ACI techniques, but with simplified procedure, low complication rate and better graft quality in the third-generation ACI technique. ACI based on the experience of cell-based therapy, with the high potential to regenerate hyaline-like tissue, represents clinical development in treatment of large-sized and full-thickness knee cartilage defects. IV.

  10. Evaluation of dermal-epidermal skin equivalents ('composite-skin') of human keratinocytes in a collagen-glycosaminoglycan matrix(Integra artificial skin).

    PubMed

    Kremer, M; Lang, E; Berger, A C

    2000-09-01

    Integra artificial skin (Integra LifeSciences Corp., Plainsboro, NJ, USA) is a dermal template consisting of bovine collagen, chondroitin-6-sulphate and a silastic membrane manufactured as Integra. This product has gained widespread use in the clinical treatment of third degree burn wounds and full thickness skin defects of different aetiologies. The product was designed to significantly reduce the time needed to achieve final wound closure in the treatment of major burn wounds, to optimise the sparse autologous donor skin resources and to improve the durable mechanical quality of the skin substitute. The clinical procedure requires two stages. The first step creates a self neodermis, the second creates a self epidermis on the neodermis. However, it is desirable to cover major burn wounds early in a single step by a skin substitute consisting of a dermal equivalent seeded in vitro with autologous keratinocytes ('composite-skin') out of which a full thickness skin develops in vivo.The goal of this experimental study was to develop a method to integrate human keratinocytes in homogeneous distribution and depth into Integra Artificial Skin. The seeded cell-matrix composites were grafted onto athymic mice in order to evaluate their potential to reconstitute a human epidermis in vivo. We were able to demonstrate that the inoculated human keratinocytes reproducibly displayed a homogeneous pattern of distribution, adherence, proliferation and confluence. The cell-matrix composites grafted in this model exhibited good wound adherence, complete healing, minor wound contraction and had the potential to reconstitute an elastic, functional and durable human skin. Histologically we were able to show that the inoculated human keratinocytes in vivo colonised the matrix in a histomorphologically characteristic epidermal pattern (keratomorula, keratinocyte bubbling) and developed a persisting, stratified, keratinising epidermis which immunohistologically proved to be of human origin. These experimental results demonstrate the establishment of an effective cell cultivation process which may be suitable for scale-up production of the epidermal component as large-scale composite-skin grafts. When seeded into Integratrade mark and grafted onto the nude mouse a replacement skin with normal functioning dermal-epidermal components was developed. These results encourage the design of a clinical trial to assess the function of this composite graft in man.

  11. Comparison of interleukin 10 homologs on dermal wound healing using a novel human skin ex vivo organ culture model

    PubMed Central

    Balaji, Swathi; Moles, Chad M.; Bhattacharya, Sukanta S.; LeSaint, Maria; Dhamija, Yashu; Le, Louis D.; King, Alice; Kidd, Mykia; Bouso, Muhammad F.; Shaaban, Aimen; Crombleholme, Timothy M.; Bollyky, Paul; Keswani, Sundeep G.

    2015-01-01

    Background Anti-inflammatory cytokine interleukin (IL)-10 has been shown to induce regenerative healing in postnatal wounds. A viral homolog of IL-10 produced by human cytomegalovirus (CMV IL-10) similarly generates potent immunoregulatory effects, but its effects on wound healing have not been investigated. Currently, there are limited cost-effective methods of screening vulnerary therapeutics. Taken together, we aim to develop and validate a novel human ex vivo dermal wound model and hypothesize that CMV IL-10 will enhance dermal wound healing. Methods Full-thickness circular (6-mm) explants were taken from surgical skin samples and 3-mm full-thickness wounds were created. Explants were embedded in collagen I matrix and maintained in specially formulated media with the epidermis at air–liquid interface, and treated with human IL-10 or CMV IL-10 (200 ng/mL). The viability of cultured explants was validated by histology and lactate dehydrogenase (LDH) activity. Epithelial gap, epithelial height, basal keratinocyte migration, vascular endothelial growth factor levels, and neovascularization were measured at days 3 and 7 to determine IL-10 effects on wound healing. Results Culture explants at day 7 appeared similar to fresh skin in morphology, cell, and vessel density. By day 14, the epidermis separated from the dermis and the cell density diminished. Day 7 wounds appeared viable with advancing epithelial and basal keratinocyte migration with no evidence of necrosis. Cytotoxicity analysis via the quantification of LDH revealed no differences between controls and treated groups. There was a slight increase in the quantity of LDH in media at day 3; however, this decreased at day 5 and continued to decline up to day 21. CMV IL-10 treatment resulted in a significant decrease in the epithelial gap and an increase in epithelial height. There were no differences in the rates of basal keratinocyte migration at day 7 between treated and control groups. Interestingly, human IL-10 increased vascular endothelial growth factor expression and neovascularization compared with controls. Conclusions The human ex vivo wound model provides a simple and viable design to study dermal wound healing. Both IL-10 homologs demonstrate vulnerary effects. The viral homolog demonstrates enhanced effects on wound closure compared with human IL-10. These data represent a novel tool that can be used to screen therapeutics, such as CMV IL-10, before preclinical studies. PMID:24814764

  12. Further morphological evidence on South African earliest Homo lower postcanine dentition: Enamel thickness and enamel dentine junction.

    PubMed

    Pan, Lei; Dumoncel, Jean; de Beer, Frikkie; Hoffman, Jakobus; Thackeray, John Francis; Duployer, Benjamin; Tenailleau, Christophe; Braga, José

    2016-07-01

    The appearance of the earliest members of the genus Homo in South Africa represents a key event in human evolution. Although enamel thickness and enamel dentine junction (EDJ) morphology preserve important information about hominin systematics and dietary adaptation, these features have not been sufficiently studied with regard to early Homo. We used micro-CT to compare enamel thickness and EDJ morphology among the mandibular postcanine dentitions of South African early hominins (N = 30) and extant Homo sapiens (N = 26), with special reference to early members of the genus Homo. We found that South African early Homo shows a similar enamel thickness distribution pattern to modern humans, although three-dimensional average and relative enamel thicknesses do not distinguish australopiths, early Homo, and modern humans particularly well. Based on enamel thickness distributions, our study suggests that a dietary shift occurred between australopiths and the origin of the Homo lineage. We also observed that South African early Homo postcanine EDJ combined primitive traits seen in australopith molars with derived features observed in modern human premolars. Our results confirm that some dental morphological patterns in later Homo actually occurred early in the Homo lineage, and highlight the taxonomic value of premolar EDJ morphology in hominin species. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Full-thickness skin with mature hair follicles generated from tissue culture expanded human cells.

    PubMed

    Wu, Xunwei; Scott, Larry; Washenik, Ken; Stenn, Kurt

    2014-12-01

    The goal of regenerative medicine is to reconstruct fully functional organs from tissue culture expanded human cells. In this study, we report a method for human reconstructed skin (hRSK) when starting with human cells. We implanted tissue culture expanded human epidermal and dermal cells into an excision wound on the back of immunodeficient mice. Pigmented skin covered the wound 4 weeks after implantation. Hair shafts were visible at 12 weeks and prominent at 14 weeks. Histologically, the hRSK comprises an intact epidermis and dermis with mature hair follicles, sebaceous glands and most notably, and unique to this system, subcutis. Morphogenesis, differentiation, and maturation of the hRSK mirror the human fetal process. Human antigen markers demonstrate that the constituent cells are of human origin for at least 6 months. The degree of new skin formation is most complete when using tissue culture expanded cells from fetal skin, but it also occurs with expanded newborn and adult cells; however, no appendages formed when we grafted both adult dermal and epidermal cells. The hRSK system promises to be valuable as a laboratory model for studying biological, pathological, and pharmaceutical problems of human skin.

  14. Effects of oriental sweet gum storax on porcine wound healing.

    PubMed

    Ocsel, Hakan; Teke, Zafer; Sacar, Mustafa; Kabay, Burhan; Duzcan, S Ender; Kara, Inci Gokalan

    2012-08-01

    The objective of the present study was to assess the effects of oriental sweet gum (Liquidambar orientalis Mill.) storax on partial-thickness and full-thickness wounds compared to conventional wound dressings in a porcine model. Six young Yorkshire pigs were used. Sixteen square excisional wounds measuring 3 × 3 cm were performed per animal. The wounds were allocated to one of the four treatment modalities: storax, hydrocolloid dressing, silver sulfadiazine, and control groups. Partial-thickness wounds were created in two pigs, and tissue samples were harvested on days 4 and 8, respectively. Full-thickness wounds were created in four pigs, and tissue samples were taken on days 4, 8, 14, and 21, respectively. Histologically, all wounds were examined for re-epithelialization and granulation tissue formation. Tissue hydroxyproline content and wound contraction areas were measured. In storax-applied group, there was a greater depth of granulation tissue at 4 and 8 days compared to all other groups (p < .0125), and there was a faster re-epithelialization at 21 days compared to both hydrocolloid dressing and control groups in full-thickness wounds (p < .0125). Tissue hydroxyproline content and wound contraction did not differ significantly between the groups. The results of this study indicate that topical application of storax enhanced both re-epithelialization and granulation tissue formation in full-thickness wounds. Further studies are indicated in this important area of wound healing research to evaluate the clinical efficacy of this storax and search for the mechanisms that explain its effects.

  15. A Computer Program to Evaluate Experimental Therapies for Treating Burned Patients

    PubMed Central

    Flora, Jairus D.; Flora, Sharyl Ann

    1980-01-01

    Determining the worth of new therapies for burn patients has been difficult because of the rarity of the burn injury and the disparate survival chances associated with different sizes of burns. Recently a burn survival model has been developed that estimates the risk of death from a burn as a function of the patient's age, sex, area of full thickness (third degree) burn, area of partial thickness burn, involvement of the perineum, and time from burn to admission. An alternative risk model uses the total area burned in place of the areas of partial thickness burn and full thickness burn, and is appropriate if the amount of full thickness burn is not determined accurately. This paper describes a program that uses these risk models to correct or standardize for demographic and severity factors, then, after that adjustment, tests whether a group of burn patients who received a new or experimental therapy shows a significantly better survival rate than that predicted by a baseline model. The program is a simple one written in Fortran for easy adaptation to other computer systems.

  16. The Combination of Preoperative Bone Marrow Lesions and Partial-Thickness Cartilage Loss Did Not Result in Inferior Outcomes After Medial Unicompartmental Knee Arthroplasty.

    PubMed

    Berend, Keith R; Lombardi, Adolph V; Jacobs, Cale A

    2017-10-01

    The purpose of this study is to compare patient-reported outcomes and revision rates between medial unicompartmental knee arthroplasty (UKA) patients based on the presence of medial bone marrow lesions (BMLs) and/or partial- vs full-thickness cartilage loss. BMLs were graded on preoperative magnetic resonance imaging (MRI) findings from 174 UKAs performed between 2009 and 2013 using the MRI Osteoarthritis Knee Score criteria by a single evaluator blinded to the patient's outcome. A second evaluator blinded to the MRI findings and postoperative outcomes assessed medial joint space present on both weight-bearing and valgus stress radiographs. Preoperative and postoperative Knee Society Knee Scores, Pain Scores, and Function Scores were then compared between 4 groups of patients: patients with BML with either partial- or full-thickness cartilage loss, and patients without BML with either partial- or full-thickness cartilage loss. In total, 152 of 174 (87%) patients had minimum 2-year follow-up. One patient in the no BML/full-thickness loss group was converted to total knee arthroplasty secondary to arthrofibrosis; however, there were no statistical differences in revision rate between the 4 groups as no other revisions were performed (P = .61). Similarly, preoperative and postoperative Knee Society Knee Scores, Pain Scores, and Function Scores did not differ between groups, nor did postoperative University of California, Los Angeles activity scores. Medial tibial BMLs were not associated with inferior outcomes, either in patients with partial- or full-thickness cartilage loss. Although the current results do not allow for the presence of preoperative BML to be considered an indication for UKA, these results definitively support that BMLs are not a contraindication for medial UKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Full-Depth Asphalt Pavements for Parking Lots and Driveways.

    ERIC Educational Resources Information Center

    Asphalt Inst., College Park, MD.

    The latest information for designing full-depth asphalt pavements for parking lots and driveways is covered in relationship to the continued increase in vehicle registration. It is based on The Asphalt Institute's Thickness Design Manual, Series No. 1 (MS-1), Seventh Edition, which covers all aspects of asphalt pavement thickness design in detail,…

  18. 49 CFR 173.137 - Class 8-Assignment of packing group.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... subchapter) as follows: (a) Packing Group I. Materials that cause full thickness destruction of intact skin... full thickness destruction of intact skin tissue within an observation period of up to 14 days starting... destruction of intact skin tissue within an observation period of up to 14 days starting after the exposure...

  19. Learning curve of office-based ultrasonography for rotator cuff tendons tears.

    PubMed

    Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook

    2013-07-01

    To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.

  20. Automatic cortical thickness analysis on rodent brain

    NASA Astrophysics Data System (ADS)

    Lee, Joohwi; Ehlers, Cindy; Crews, Fulton; Niethammer, Marc; Budin, Francois; Paniagua, Beatriz; Sulik, Kathy; Johns, Josephine; Styner, Martin; Oguz, Ipek

    2011-03-01

    Localized difference in the cortex is one of the most useful morphometric traits in human and animal brain studies. There are many tools and methods already developed to automatically measure and analyze cortical thickness for the human brain. However, these tools cannot be directly applied to rodent brains due to the different scales; even adult rodent brains are 50 to 100 times smaller than humans. This paper describes an algorithm for automatically measuring the cortical thickness of mouse and rat brains. The algorithm consists of three steps: segmentation, thickness measurement, and statistical analysis among experimental groups. The segmentation step provides the neocortex separation from other brain structures and thus is a preprocessing step for the thickness measurement. In the thickness measurement step, the thickness is computed by solving a Laplacian PDE and a transport equation. The Laplacian PDE first creates streamlines as an analogy of cortical columns; the transport equation computes the length of the streamlines. The result is stored as a thickness map over the neocortex surface. For the statistical analysis, it is important to sample thickness at corresponding points. This is achieved by the particle correspondence algorithm which minimizes entropy between dynamically moving sample points called particles. Since the computational cost of the correspondence algorithm may limit the number of corresponding points, we use thin-plate spline based interpolation to increase the number of corresponding sample points. As a driving application, we measured the thickness difference to assess the effects of adolescent intermittent ethanol exposure that persist into adulthood and performed t-test between the control and exposed rat groups. We found significantly differing regions in both hemispheres.

  1. Pediatric Helicobacter pylori gastropathy demonstrates a unique pattern of gastric foveolar hyperplasia.

    PubMed

    Saghier, Sadaf; Schwarz, Steven M; Anderson, Virginia; Gupta, Raavi; Heidarian, Amin; Rabinowitz, Simon S

    2018-04-25

    Helicobacter pylori (Hp) are the most common agents causing gastric mucosal injury worldwide. Foveolar hyperplasia is a key component of the stomach's reaction to injury. This study examines histopathologic characteristics associated with Helicobacter pylori and with non- Helicobacter pylori-associated gastropathy in children and adolescents, and compares the prevalence of foveolar hyperplasia among these disease subgroups and normal control subjects. Eighty-one gastric antral and corpus biopsies from subjects 2-19 years of age were studied. Twenty-two subjects with Helicobacter pylori gastritis were compared to 23 with non-Helicobacter pylori gastropathy and to 36 controls (normal biopsies). Foveolar length, full mucosal thickness, and the foveolar length: full mucosal thickness ratio were derived by a morphometric technique previously developed to analyze adult gastric tissue. Compared to controls, Helicobacter pylori gastritis demonstrated significant increases in antral foveolar length (P < .0001), full mucosal thickness (P < .0001), as well as corpus foveolar length (P < .05) and corpus full mucosal thickness (P < .05). Non-Helicobacter pylori-associated gastropathy also was characterized by increased antral foveolar length (P < .0001) and full mucosal thickness (P < .001) but corresponding corpus measurements did not differ from controls. Antral foveolar length in non-Helicobacter pylori gastropathy was increased, when compared to Helicobacter pylori gastritis (P < .05), while corpus values were not. The non-Helicobacter pylori gastropathy group demonstrated increased antral foveolar length: full mucosal thickness ratios, compared with Helicobacter pylori gastritis (P < .001) and with normal controls (P < .0001). An objective, quantitative approach to measuring foveolar hyperplasia in adults was successfully applied to pediatric biopsies and yielded a richer characterization of gastric pathology in children. Foveolar hyperplasia appears to be a generalized phenomenon in the presence of pediatric Helicobacter pylori gastritis but is limited to the antrum in non-Helicobacter pylori gastropathy. © 2018 John Wiley & Sons Ltd.

  2. Human Skin 3D Bioprinting Using Scaffold-Free Approach.

    PubMed

    Pourchet, Léa J; Thepot, Amélie; Albouy, Marion; Courtial, Edwin J; Boher, Aurélie; Blum, Loïc J; Marquette, Christophe A

    2017-02-01

    Organ in vitro synthesis is one of the last bottlenecks between tissue engineering and transplantation of synthetic organs. Bioprinting has proven its capacity to produce 3D objects composed of living cells but highly organized tissues such as full thickness skin (dermis + epidermis) are rarely attained. The focus of the present study is to demonstrate the capability of a newly developed ink formulation and the use of an open source printer, for the production of a really complete skin model. Proofs are given through immunostaining and electronic microscopy that the bioprinted skin presents all characteristics of human skin, both at the molecular and macromolecular level. Finally, the printability of large skin objects is demonstrated with the printing of an adult-size ear. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Learning from regeneration research organisms: The circuitous road to scar free wound healing.

    PubMed

    Erickson, Jami R; Echeverri, Karen

    2018-01-15

    The skin is the largest organ in the body and plays multiple essential roles ranging from regulating temperature, preventing infection and ultimately defining who we are physically. It is a highly dynamic organ that constantly replaces the outermost cells throughout life. However, when faced with a major injury, human skin cannot restore a significant lesion to its original functionality, instead a reparative scar is formed. In contrast to this, many other species have the unique ability to regenerate full thickness skin without formation of scar tissue. Here we review recent advances in the field that shed light on how the skin cells in regenerative species react to injury to prevent scar formation versus scar forming humans. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Mapping the spatial and temporal progression of human dental enamel biomineralization using synchrotron X-ray diffraction.

    PubMed

    Simmons, Lisa M; Montgomery, Janet; Beaumont, Julia; Davis, Graham R; Al-Jawad, Maisoon

    2013-11-01

    The complex biological, physicochemical process of human dental enamel formation begins in utero and for most teeth takes several years to complete. Lost enamel tissue cannot regenerate, therefore a better understanding of the spatial and temporal progression of mineralization of this tissue is needed in order to design improved in vivo mineral growth processes for regenerative dentistry and allow the possibility to grow a synthetic whole or partial tooth. Human dental enamel samples across a range of developmental stages available through archaeological collections have been used to explore the spatial and temporal progression of enamel biomineralization. Position sensitive synchrotron X-ray diffraction was used to quantify spatial and temporal variations in crystallite organization, lattice parameters and crystallite thickness at three different stages in enamel maturation. In addition X-ray microtomography was used to study mineral content distributions. An inverse correlation was found between the spatial variation in mineral content and the distribution of crystallite organization and thickness as a function of time during enamel maturation. Combined X-ray microtomography and synchrotron X-ray diffraction results show that as enamel matures the mineral content increases and the mineral density distribution becomes more homogeneous. Starting concurrently but proceeding at a slower rate, the enamel crystallites become more oriented and larger; and the crystallite organization becomes spatially more complex and heterogeneous. During the mineralization of human dental enamel, the rate of mineral formation and mineral organization are not identical. Whilst the processes start simultaneously, full mineral content is achieved earlier, and crystallite organization is slower and continues for longer. These findings provide detailed insights into mineral development in human dental enamel which can inform synthetic biomimetic approaches for the benefit of clinical dentistry. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Human skin cell fractions fail to self-organize within a gellan gum/hyaluronic acid matrix but positively influence early wound healing.

    PubMed

    Cerqueira, Mariana T; da Silva, Lucília P; Santos, Tírcia C; Pirraco, Rogério P; Correlo, Vitor M; Marques, Alexandra P; Reis, Rui L

    2014-05-01

    Split-thickness autografts still are the current gold standard to treat skin, upon severe injuries. Nonetheless, autografts are dependent on donor site availability and often associated to poor quality neoskin. The generation of dermal-epidermal substitutes by tissue engineering is seen as a promising strategy to overcome this problematic. However, solutions that can be safely and conveniently transplanted in one single surgical intervention are still very challenging as their production normally requires long culture time, and graft survival is many times compromised by delayed vascularization upon transplantation. This work intended to propose a strategy that circumvents the prolonged and laborious preparation period of skin substitutes and allows skin cells self-organization toward improved healing. Human dermal/epidermal cell fractions were entrapped directly from isolation within a gellan gum/hyaluronic acid (GG-HA) spongy-like hydrogel formed from an off-the-shelf dried polymeric network. Upon transplantation into full-thickness mice wounds, the proposed constructs accelerated the wound closure rate and re-epithelialization, as well as tissue neovascularization. A synergistic effect of the GG-HA matrix and the transplanted cells over those processes was demonstrated at early time points. Despite the human-derived and chimeric blood vessels found, the proposed matrix did not succeed in prolonging cells residence time and in sustaining the self-organization of transplanted human cells possibly due to primitive degradation. Despite this, the herein proposed approach open the opportunity to tackle wound healing at early stages contributing to re-epithelialization and neovascularization.

  6. Human Skin Cell Fractions Fail to Self-Organize Within a Gellan Gum/Hyaluronic Acid Matrix but Positively Influence Early Wound Healing

    PubMed Central

    Cerqueira, Mariana T.; da Silva, Lucília P.; Santos, Tírcia C.; Pirraco, Rogério P.; Correlo, Vitor M.; Reis, Rui L.

    2014-01-01

    Split-thickness autografts still are the current gold standard to treat skin, upon severe injuries. Nonetheless, autografts are dependent on donor site availability and often associated to poor quality neoskin. The generation of dermal–epidermal substitutes by tissue engineering is seen as a promising strategy to overcome this problematic. However, solutions that can be safely and conveniently transplanted in one single surgical intervention are still very challenging as their production normally requires long culture time, and graft survival is many times compromised by delayed vascularization upon transplantation. This work intended to propose a strategy that circumvents the prolonged and laborious preparation period of skin substitutes and allows skin cells self-organization toward improved healing. Human dermal/epidermal cell fractions were entrapped directly from isolation within a gellan gum/hyaluronic acid (GG-HA) spongy-like hydrogel formed from an off-the-shelf dried polymeric network. Upon transplantation into full-thickness mice wounds, the proposed constructs accelerated the wound closure rate and re-epithelialization, as well as tissue neovascularization. A synergistic effect of the GG-HA matrix and the transplanted cells over those processes was demonstrated at early time points. Despite the human-derived and chimeric blood vessels found, the proposed matrix did not succeed in prolonging cells residence time and in sustaining the self-organization of transplanted human cells possibly due to primitive degradation. Despite this, the herein proposed approach open the opportunity to tackle wound healing at early stages contributing to re-epithelialization and neovascularization. PMID:24299468

  7. Thickness-dependent electrocaloric effect in mixed-phase Pb0.87Ba0.1 La0.02(Zr0.6Sn0.33Ti0.07)O3 thin films

    PubMed Central

    Correia, T. M.

    2016-01-01

    Full-perovskite Pb0.87Ba0.1La0.02(Zr0.6Sn0.33Ti0.07)O3 (PBLZST) thin films were fabricated by a sol–gel method. These revealed both rhombohedral and tetragonal phases, as opposed to the full-tetragonal phase previously reported in ceramics. The fractions of tetragonal and rhombohedral phases are found to be strongly dependent on film thickness. The fraction of tetragonal grains increases with increasing film thickness, as the substrate constraint throughout the film decreases with film thickness. The maximum of the dielectric constant (εm) and the corresponding temperature (Tm) are thickness-dependent and dictated by the fraction of rhombohedral and tetragonal phase, with εm reaching a minimum at 400 nm and Tm shifting to higher temperature with increasing thickness. With the thickness increase, the breakdown field decreases, but field-induced antiferroelectric–ferroelectric (EAFE−FE) and ferroelectric–antiferroelectric (EFE−AFE) switch fields increase. The electrocaloric effect increases with increasing film thickness. This article is part of the themed issue ‘Taking the temperature of phase transitions in cool materials’. PMID:27402937

  8. Electromechanical properties of human osteoarthritic and asymptomatic articular cartilage are sensitive and early detectors of degeneration.

    PubMed

    Hadjab, I; Sim, S; Karhula, S S; Kauppinen, S; Garon, M; Quenneville, E; Lavigne, P; Lehenkari, P P; Saarakkala, S; Buschmann, M D

    2018-03-01

    To evaluate cross-correlations of ex vivo electromechanical properties with cartilage and subchondral bone plate thickness, as well as their sensitivity and specificity regarding early cartilage degeneration in human tibial plateau. Six pairs of tibial plateaus were assessed ex vivo using an electromechanical probe (Arthro-BST) which measures a quantitative parameter (QP) reflecting articular cartilage compression-induced streaming potentials. Cartilage thickness was then measured with an automated thickness mapping technique using Mach-1 multiaxial mechanical tester. Subsequently, a visual assessment was performed by an experienced orthopedic surgeon using the International Cartilage Repair Society (ICRS) grading system. Each tibial plateau was finally evaluated with μCT scanner to determine the subchondral-bone plate thickness over the entire surface. Cross-correlations between assessments decreased with increasing degeneration level. Moreover, electromechanical QP and subchondral-bone plate thickness increased strongly with ICRS grade (ρ = 0.86 and ρ = 0.54 respectively), while cartilage thickness slightly increased (ρ = 0.27). Sensitivity and specificity analysis revealed that the electromechanical QP is the most performant to distinguish between different early degeneration stages, followed by subchondral-bone plate thickness and then cartilage thickness. Lastly, effect sizes of cartilage and subchondral-bone properties were established to evaluate whether cartilage or bone showed the most noticeable changes between normal (ICRS 0) and each early degenerative stage. Thus, the effect sizes of cartilage electromechanical QP were almost twice those of the subchondral-bone plate thickness, indicating greater sensitivity of electromechanical measurements to detect early osteoarthritis. The potential of electromechanical properties for the diagnosis of early human cartilage degeneration was highlighted and supported by cartilage thickness and μCT assessments. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  9. Influence of a fat layer on the near infrared spectra of human muscle: quantitative analysis based on two-layered Monte Carlo simulations and phantom experiments

    NASA Technical Reports Server (NTRS)

    Yang, Ye; Soyemi, Olusola O.; Landry, Michelle R.; Soller, Babs R.

    2005-01-01

    The influence of fat thickness on the diffuse reflectance spectra of muscle in the near infrared (NIR) region is studied by Monte Carlo simulations of a two-layer structure and with phantom experiments. A polynomial relationship was established between the fat thickness and the detected diffuse reflectance. The influence of a range of optical coefficients (absorption and reduced scattering) for fat and muscle over the known range of human physiological values was also investigated. Subject-to-subject variation in the fat optical coefficients and thickness can be ignored if the fat thickness is less than 5 mm. A method was proposed to correct the fat thickness influence. c2005 Optical Society of America.

  10. Penile Analogue of Stratified Mucin-Producing Intraepithelial Lesion of the Cervix: The First Described Case. A Diagnostic Pitfall.

    PubMed

    Michal, Michael; Michal, Michal; Miesbauerova, Marketa; Hercogova, Jana; Skopalikova, Barbora; Kazakov, Dmitry V

    2016-05-01

    The authors report a case where undifferentiated (classic) penile intraepithelial neoplasia was associated with the presence of goblet cells throughout the full epithelial thickness and which later progressed into an invasive carcinoma. The lesion evolved in three consecutive biopsies from only surface epithelium occupying numerous goblet cells in the first to variably sized solid nodules in the dermis composed of atypical squamous and/or basaloid cells intermixed with numerous goblet cells in the third biopsy. Both cellular components expressed CK7 and p16 protein. Human Papillomavirus (HPV) genotyping revealed high risk HPV type 16. To the best of our knowledge, this is the first description of such a lesion occurring on the penis, which can be considered the penile analogue of cervical stratified mucin-producing intraepithelial lesion (SMILE). The correct diagnosis was rendered retrospectively, after recognition of the existence of a vulvar lesion resembling cervical SMILE. The initial biopsy was misinterpreted as extramammary Paget disease, which also constitutes the main pitfall in the differential diagnosis. Another important differential diagnosis is penile/vulvar mucinous metaplasia. The finding of atypical squamous epithelial cells positive for p16 associated with mucinous cells present throughout the full epithelial thickness is a clue to the diagnosis of penile SMILE.

  11. Improved Methods to Produce Tissue-Engineered Skin Substitutes Suitable for the Permanent Closure of Full-Thickness Skin Injuries

    PubMed Central

    Larouche, Danielle; Cantin-Warren, Laurence; Desgagné, Maxime; Guignard, Rina; Martel, Israël; Ayoub, Akram; Lavoie, Amélie; Gauvin, Robert; Auger, François A.; Moulin, Véronique J.; Germain, Lucie

    2016-01-01

    Abstract There is a clinical need for skin substitutes to replace full-thickness skin loss. Our group has developed a bilayered skin substitute produced from the patient's own fibroblasts and keratinocytes referred to as Self-Assembled Skin Substitute (SASS). After cell isolation and expansion, the current time required to produce SASS is 45 days. We aimed to optimize the manufacturing process to standardize the production of SASS and to reduce production time. The new approach consisted in seeding keratinocytes on a fibroblast-derived tissue sheet before its detachment from the culture plate. Four days following keratinocyte seeding, the resulting tissue was stacked on two fibroblast-derived tissue sheets and cultured at the air–liquid interface for 10 days. The resulting total production time was 31 days. An alternative method adapted to more contractile fibroblasts was also developed. It consisted in adding a peripheral frame before seeding fibroblasts in the culture plate. SASSs produced by both new methods shared similar histology, contractile behavior in vitro and in vivo evolution after grafting onto mice when compared with SASSs produced by the 45-day standard method. In conclusion, the new approach for the production of high-quality human skin substitutes should allow an earlier autologous grafting for the treatment of severely burned patients. PMID:27872793

  12. The healing effects of autologous platelet gel on acute human skin wounds.

    PubMed

    Hom, David B; Linzie, Bradley M; Huang, Trevor C

    2007-01-01

    To compare the healing of full-thickness skin punch wounds treated with topical autologous platelet gel (APG) vs conventional therapy (antibiotic ointment and/or occlusive dressings) in healthy volunteers. A prospective, single-blind, pilot study comprising 80 full-thickness skin punch wounds (4 mm diameter) was conducted on the thighs of 8 healthy volunteers. With each subject serving as his or her own control (5 punch sites per leg), APG was applied topically on one thigh, and an antibiotic ointment and/or a semiocclusive dressing was applied on the other thigh. Healing was monitored for spontaneous wound closure by clinical assessment and by digital photographs over 6 months. Over 35 days, 64 serial dermal biopsy specimens (6 mm diameter) were analyzed (using hematoxylin-eosin, Mason trichrome, CD-34, and Ki-67 stains) to measure differences between treated and control sites for cellularity, granulation formation, vascularity, epithelialization, and cellular replication. Over a 42-day period, the APG-treated sites had statistically increased wound closure compared with controls by visual clinical assessment and by digital planimetry photographic measurements (P

  13. [Repairing severe cicatricial contracture deformity in web-space by kite-like incision combined with full-thickness skin grafting].

    PubMed

    Liang, Liming; Chai, Jiake; Jia, Xiaoming; Wang, Yirong; Meng, Suyu; Liu, Tao

    2012-12-01

    To investigate the effectiveness of repairing severe cicatricial contracture deformity in the web-space by kite-like incision combined with full-thickness skin grafting. Between June 2008 and September 2011, 31 patients (87 web-spaces) with severe cicatricial contracture deformities in the web-spaces were treated. There were 24 males and 7 females, aged 5-43 years (median, 22 years). The causes of injuries were flame burn (26 cases), scald (3 cases), electric arc burn (1 case), and chemical burn (1 case). The degree of burn was deep second degree (14 cases) and third degree (17 cases). The interval time from injury to operation was 10 months to 17 years (median, 2.2 years). The kite-like incision was marked on the scar in the web-space. The rhombic scar between the adjacent metacarpophalangeal joints was excised, and cicatricial contracture was released completely. The secondary wound in the web-space was repaired with full-thickness autogeneic skin grafting. The secondary wound at donor site was directly sutured. All full-thickness skin grafts survived well. The incisions at donor sites healed primarily. Of 31 patients, 29 (82 web-spaces) were followed up 6-18 months (mean, 13 months). The sizes and depths of reconstructed web-spaces were similar to those of normal ones. No secondary cicatricial contracture was observed, and the function of fingers recovered well. The short-term effectiveness is satisfactory by kite-like incision combined with full-thickness skin grafting for repairing severe cicatricial contracture deformities in the web-space, while the long-term effectiveness needs further observation.

  14. [Vacuum sealing drainage combined with free skin graft in repairing cutaneous deficiency of traumatic shank amputation stump].

    PubMed

    Zhao, Xiao-fei; Li, Chun-you; Jin, Guo-qiang; Ming, Xiao-feng; Wang, Guo-jie

    2014-12-01

    To observe clinical efficacy in treating cutaneous deficiency of traumatic shank amputation stump with full-thickness skin graft combined with vacuum sealing drainage. From September 2009 to December 2012, 15 patients with cutaneous deficiency of traumatic shank amputation stump were treated with full-thickness skin graft combined with vacuum sealing drainage. Among patients, there were 11 males and 4 females with an average age of 41.5 (ranged from 25 to 62) years old. Ten cases were caused by traffic accident and 5 cases were caused by heavy object, 9 cases on left and 6 cases on right. Six patients with smashed wound were treated with debridement and amputation, combined with vacuum aspiration in-emergency; 9 patients caused by infection and necrosis were treated with debridement and amputation, combined with vacuum aspiration, and full-thickness skin graft were performed at stage II. The skin defect area of residual limbs ranged from 40 cm x 20 cm to 25 cm x 15 cm. All patients were followed up from 3 months to 1 year. Full-thickness skin graft of residual limbs were survived,and obtained satisfactory walking function with prosthetic. Residual skin increased thicken, wearproof without rupture and pain. Full-thickness skin graft combined with vacuum sealing drainage in treating cutaneous deficiency of traumatic shank amputation stump could reserve the length of residual limbs, increase survival rate of skin graft with less scar of survival skin, get good wearability and it is conducive to prosthetic wear. It is a simple and easy treatment method.

  15. Full thickness skin grafts in periocular reconstructions: long-term outcomes.

    PubMed

    Rathore, Deepa S; Chickadasarahilli, Swaroop; Crossman, Richard; Mehta, Purnima; Ahluwalia, Harpreet Singh

    2014-01-01

    To evaluate the outcomes of eyelid reconstruction in patients who underwent full thickness skin grafts. A retrospective, noncomparative intervention study of patients who underwent periocular reconstruction with full thickness skin grafts between 2005 and 2011. One hundred consecutive Caucasian patients were included in the study, 54 women and 46 men. Mean follow up was 32 months. Indications for full thickness skin grafts were excision of eyelid tumors (98%) and cicatricial ectropion (2%). Site of lid defects were lower lid (60%), medial canthus (32%), upper lid (6%), and lateral canthus (2%). The skin graft donor sites were supraclavicular (44%), upper eyelid (24%), inner brachial (18%), and postauricular (14%).Early postoperative complications included lower eyelid graft contracture (1%) and partial failure (1%). Late sequelae included lower eyelid graft contracture (4%) and hypertrophic scarring (23%). Of the 23 patients with hypertrophic scar, 21 achieved good outcomes following massage with silicone gel and steroid ointment and 2 had persistent moderate lumpiness. No statistically significant association was found between graft hypertrophy and donor site or graft size. As high as 95% of all patients achieved good final eyelid position. Good color match was seen in 94% and graft hypopigmentation in 6%. An association between hypopigmentation and supraclavicular and inner brachial donor site was found to be statistically significant. Most patients (94%) achieved good eyelid position and color match. Majority (91%) of the early postoperative cicatricial sequelae can be reversed by massage, steroid ointment, and silicone gel application. Full thickness skin grafts have excellent graft survival rates and have minimal donor site morbidity.

  16. Do Magnetic Resonance Imaging Characteristics of Full-Thickness Rotator Cuff Tears Correlate With Sleep Disturbance?

    PubMed

    Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S

    2017-11-01

    Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.

  17. Duodenal endoscopic full-thickness resection (with video).

    PubMed

    Schmidt, Arthur; Meier, Benjamin; Cahyadi, Oscar; Caca, Karel

    2015-10-01

    Endoscopic resection of duodenal non-lifting adenomas and subepithelial tumors is challenging and harbors a significant risk of adverse events. We report on a novel technique for duodenal endoscopic full-thickness resection (EFTR) by using an over-the-scope device. Data of 4 consecutive patients who underwent duodenal EFTR were analyzed retrospectively. Main outcome measures were technical success, R0 resection, histologic confirmation of full-thickness resection, and adverse events. Resections were done with a novel, over-the-scope device (full-thickness resection device, FTRD). Four patients (median age 60 years) with non-lifting adenomas (2 patients) or subepithelial tumors (2 patients) underwent EFTR in the duodenum. All lesions could be resected successfully. Mean procedure time was 67.5 minutes (range 50-85 minutes). Minor bleeding was observed in 2 cases; blood transfusions were not required. There was no immediate or delayed perforation. Mean diameter of the resection specimen was 28.3 mm (range 22-40 mm). Histology confirmed complete (R0) full-thickness resection in 3 of 4 cases. To date, 2-month endoscopic follow-up has been obtained in 3 patients. In all cases, the over-the-scope clip was still in place and could be removed without adverse events; recurrences were not observed. EFTR in the duodenum with the FTRD is a promising technique that has the potential to spare surgical resections. Modifications of the device should be made to facilitate introduction by mouth. Prospective studies are needed to further evaluate efficacy and safety for duodenal resections. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  18. Synthesis and preparation of biodegradable hybrid dextran hydrogel incorporated with biodegradable curcumin nanomicelles for full thickness wound healing.

    PubMed

    Alibolandi, Mona; Mohammadi, Marzieh; Taghdisi, Seyed Mohammad; Abnous, Khalil; Ramezani, Mohammad

    2017-10-30

    There is a clinical need for a novel, more efficient therapy for full thickness wound healing. In the current study, curcumin encapsulated PEG-PLA [poly(lactide)-block-poly(ethylene glycol)] nanomicelles were incorporated into dextran hydrogel for a full thickness dermal wound healing application. To assess the application of the hydrogel as a therapeutic wound dressing, its morphology, swelling pattern, kinetics of degradation, and capacity to control curcumin release were evaluated. It was found that the prepared hybrid hydrogel had acceptable biocompatibility, incorporation capacity of curcumin nanomicelles, and mechanical properties. An in vitro release experiment also demonstrated the sustained release of curcumin from dextran hydrogel, which was first controlled by the diffusion of curcumin from hydrogel and continued through hydrogel matrix erosion at the terminal phase. An in vivo wound healing experiment was carried out using dressing hydrogels on full thickness wounds in BALB/c mice. An histological study demonstrated that the application of curcumin nanomicelles incorporated hydrogel could significantly augment the re-epithelialization of epidermis and collagen deposition in the wound area. Expression of CD31 and vimentin in wound tissue was investigated using immunohistochemistry tests on the eighth day post wounding. The results obtained demonstrated that curcumin nanomicelles incorporated hydrogel could significantly accelerate angiogenesis, fibroblast accumulation, and the process of wound healing. Together, the data indicate that the prepared hybrid curcumin PEG-PLA nanomicelles incorporated dextran hydrogel is a promising candidate for full thickness wound treatment that increases re-epithelialization, collagen deposition, angiogenesis, and tissue granulation. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development of a primary melanoma in situ within a full-thickness skin graft overlying a free muscle flap: a case report.

    PubMed

    Dabek, Robert J; Baletic, Nemanja; McUmber, Harrison; Nahed, Brian; Haynes, Alex; Eberlin, Kyle R; Bojovic, Branko

    2018-01-01

    The development of a primary melanoma within the confines of free tissue transfer is a rare occurrence. In this report, we describe the development of a primary melanoma in situ within a full-thickness skin graft overlying a free latissimus dorsi muscle flap used to cover a scalp defect.

  20. Shoulder disorders in an outpatient clinic: an epidemiological study.

    PubMed

    Malavolta, Eduardo Angeli; Gracitelli, Mauro Emilio Conforto; Assunção, Jorge Henrique; Pinto, Gustavo de Mello Ribeiro; da Silveira, Arthur Zorzi Freire; Ferreira, Arnaldo Amado

    2017-01-01

    To describe shoulder disorders in patients evaluated by two shoulder and elbow surgeons. This cross-sectional study analyzed patients evaluated by two authors, excluding acute fractures and dislocations and patients with symptoms not involving the shoulder. Age and sex distribution was determined for the different diagnoses. We evaluated 1001 patients. Mean age was 51.43±15.15 years and 51.0% were female. Disorders of the rotator cuff occurred in 64.3% (41.2% tendinopathy, 11.0% partial tears and 12.2% full-thickness tears). Adhesive capsulitis occurred in 13.5% of cases and glenohumeral instability in 8.1%. Rotator cuff disorders were more common in women, with a peak between 50 and 59 years for tendinopathy and partial tears and between 60 and 69 years for full-thickness tears. Glenohumeral instability was more frequent in men, with a peak between 30 and 39 years. The most frequent diagnosis was rotator cuff tendinopathy, followed by adhesive capsulitis, full-thickness rotator cuff tears, partial rotator cuff tears and glenohumeral instability. Rotator cuff lesions were more common in women, with a peak between 60 and 69 years for full-thickness tears. Level of Evidence IV, Case Series.

  1. Negative pressure wound therapy using polyvinyl alcohol foam to bolster full-thickness mesh skin grafts in dogs.

    PubMed

    Or, Matan; Van Goethem, Bart; Kitshoff, Adriaan; Koenraadt, Annika; Schwarzkopf, Ilona; Bosmans, Tim; de Rooster, Hilde

    2017-04-01

    To report the use of negative pressure wound therapy (NPWT) with polyvinyl alcohol (PVA) foam to bolster full-thickness mesh skin grafts in dogs. Retrospective case series. Client-owned dogs (n = 8). Full-thickness mesh skin graft was directly covered with PVA foam. NPWT was maintained for 5 days (in 1 or 2 cycles). Grafts were evaluated on days 2, 5, 10, 15, and 30 for graft appearance and graft take, granulation tissue formation, and complications. Firm attachment of the graft to the recipient bed was accomplished in 7 dogs with granulation tissue quickly filling the mesh holes, and graft take considered excellent. One dog had bandage complications after cessation of the NPWT, causing partial graft loss. The PVA foam did not adhere to the graft or damage the surrounding skin. The application of NPWT with a PVA foam after full-thickness mesh skin grafting in dogs provides an effective method for securing skin grafts, with good graft acceptance. PVA foam can be used as a primary dressing for skin grafts, obviating the need for other interposing materials to protect the graft and the surrounding skin. © 2017 The American College of Veterinary Surgeons.

  2. Collagen-cellulose nanocrystal scaffolds containing curcumin-loaded microspheres on infected full-thickness burns repair.

    PubMed

    Guo, Rui; Lan, Yong; Xue, Wei; Cheng, Biao; Zhang, Yuanming; Wang, Changyong; Ramakrishna, Seeram

    2017-12-01

    Burn infection is a serious problem that delays wound healing and leads to death. Curcumin (Cur) has been shown to exhibit antioxidant, anti-inflammatory, antimicrobial and anticarcinogenic activity. However, its instability, extremely low aqueous solubility and bioavailability in physiological fluids may make it difficult to maintain local Cur concentrations above the minimum inhibitory concentration for burn infection treatment. The objective of this study was to construct complexes of Cur/gelatin microspheres (GMs) and porous collagen (Coll)-cellulose nanocrystals (CNCs) composite scaffolds for full-thickness burn infection treatment. The Cur/GMs/Coll-CNCs scaffolds had high porosity, available pore size, and a long and sustained Cur release profile. Furthermore, the composite scaffold exhibited remarkably strong antibacterial activity. Hence, we evaluated the wound-healing effects and antibacterial properties of Cur/GMs/Coll-CNCs scaffolds in a rat full-thickness burn infection model. The Cur/GMs/Coll-CNCs scaffold was able to prevent not only local inflammation but also accelerated dermis regeneration. Thus, we conclude that Cur/GMs/Coll-CNCs scaffolds can act as an effective dermal regeneration template for full-thickness burn wound infection healing in rats models. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Vertex- and atlas-based comparisons in measures of cortical thickness, gyrification and white matter volume between humans and chimpanzees.

    PubMed

    Hopkins, William D; Li, Xiang; Crow, Tim; Roberts, Neil

    2017-01-01

    What changes in cortical organisation characterise global and localised variation between humans and chimpanzees remains a topic of considerable interest in evolutionary neuroscience. Here, we examined regional variation in cortical thickness, gyrification and white matter in samples of human and chimpanzee brains. Both species were MRI scanned on the same platform using identical procedures. The images were processed and segmented by FSL and FreeSurfer and the relative changes in cortical thickness, gyrification and white matter across the entire cortex were compared between species. In general, relative to chimpanzees, humans had significantly greater gyrification and significantly thinner cortex, particularly in the frontal lobe. Human brains also had disproportionately higher white matter volumes in the frontal lobe, particularly in prefrontal regions. Collectively, the findings suggest that after the split from the common ancestor, white matter expansion and subsequently increasing gyrification occurred in the frontal lobe possibly due to increased selection for human cognitive and motor specialisations.

  4. Transcriptional changes in organoculture of full-thickness human skin following topical application of all-trans retinoic acid

    PubMed Central

    Gillbro, J M; Al-Bader, T; Westman, M; Olsson, M J; Mavon, A

    2014-01-01

    Synopsis Objective Retinoids are used as therapeutic agents for numerous skin diseases, for example, psoriasis, acne and keratinization disorders. The same substances have also been recognized in the treatment for hyperpigmentation disorders such as melasma. Other studies on photo-damaged skin have shown that retinoids reduce wrinkles, surface roughness, mottled pigmentation, and visual skin appearance as a whole. We tested the hypothesis that an organoculture of full-thickness human skin could be used as a preclinical model to investigate the retinoid transcriptional profile in human skin in vitro. Methods Full-thickness skin explants were exposed to topically applied all-trans retinoic acid (RA) for 24 h. The gene expression profile was analysed using oligonucleotide microarrays, and data were validated with real-time (RT) PCR. Results We showed that the expression of 93 genes was significantly altered more than twofold. Several of the altered genes, for example, KRT4, CYP26 and LCN2, have previously been shown to be affected by RA in keratinocyte monocultures, reconstructed epidermis and skin biopsies from patients treated topically or orally with RA. In addition, genes, such as SCEL, NRIP1, DGAT2, RDH12 EfnB2, MAPK14, SAMD9 and CEACAM6 not previously reported to be affected by RA in human skin, were identified for the first time in this study. Conclusion The results in the present study show that full-thickness human explants represent a valuable pre-clinical model for studying the effects of retinoids in skin. Résumé Objectif Les rétinoïdes sont utilisés comme agents thérapeutiques pour de nombreuses maladies de la peau, p.ex. le psoriasis, l'acné et les troubles de la kératinisation. Les mêmes substances ont également été reconnues dans le traitement des troubles de l' hyperpigmentation tels que le melasma. D'autres études sur la peau photo-endommagée ont montré que les rétinoïdes réduisent les rides, la rugosité de la surface, la pigmentation tachetée, et l'aspect visuel de la peau dans son ensemble. Nous avons testé l'hypothèse selon laquelle une organoculture de épaisseur intégrale de la peau humaine pourrait être utilisée comme modèle préclinique pour étudier le profil transcriptionnel des rétinoïdes dans la peau humaine in vitro. Méthodes Des explants de peau intégrale ont été exposés à l'application topique de all-trans acide rétinoïque (RA) pendant 24 heures. Le profil d' expression des gènes a été analysé en utilisant des puces DNA array et les données ont été validées par (RT) -PCR. Resultats Nous avons montré que l'expression de 93 gènes a été modifiée de façon significative par plus d'un facteur 2. Plusieurs des gènes modifiés par exemple KRT4, CYP26 et LCN2 ont été montrés précédemment d'être affectés par RA dans les monocultures de kératinocytes, dans l'épiderme reconstruit et dans des biopsies cutanées de patients traités par voie topique ou par voie orale avec RA. En outre, des gènes tels que SCEL, NRIP1, DGAT2, RDH12 EfnB2, MAPK14, SAMD9 et CEACAM6 non signalés précédemment, sont touchés par RA dans la peau humaine, et ont été identifiés pour la première fois dans cette étude. Conclusion Les résultats de la présente étude montrent que les explants humains de pleine épaisseur représentent un modèle préclinique précieux pour l'étude des effets des rétinoïdes dans la peau. PMID:24697191

  5. Prefabricated scalping forehead flap with skeletal support.

    PubMed

    Fujiwara, Masao; Suzuki, Ayano; Mizukami, Takahide; Terai, Tsutomu; Fukamizu, Hidekazu

    2009-07-01

    It is difficult to reconstruct a nose with adequate shape, color, and texture in patients who have full-thickness nasal defects with extensive loss of skeletal support. The scalping forehead flap is a reliable technique for nasal reconstruction. To our knowledge, however, there have been no reports about a prefabricated scalping forehead flap with a bone graft as skeletal support. In the case reported here, a prefabricated scalping forehead flap combined with an iliac bone graft as skeletal support was used to successfully reconstruct a full-thickness defect of the nose associated with partial frontal bone loss and complete loss of the nasal bones. Acceptable functional and aesthetic results were achieved. This method may be a good alternative for reconstruction of full-thickness nasal defects with extensive loss of skeletal support.

  6. Complete horizontal skin cell resurfacing and delayed vertical cell infiltration into porcine reconstructive tissue matrix compared to bovine collagen matrix and human dermis.

    PubMed

    Mirastschijski, Ursula; Kerzel, Corinna; Schnabel, Reinhild; Strauss, Sarah; Breuing, Karl-Heinz

    2013-10-01

    Xenogenous dermal matrices are used for hernia repair and breast reconstruction. Full-thickness skin replacement is needed after burn or degloving injuries with exposure of tendons or bones. The authors used a human skin organ culture model to study whether porcine reconstructive tissue matrix (Strattice) is effective as a dermal tissue replacement. Skin cells or split-thickness skin grafts were seeded onto human deepidermized dermis, Strattice, and Matriderm. Cellular resurfacing and matrix infiltration were monitored by live fluorescence imaging, histology, and electron microscopy. Proliferation, apoptosis, cell differentiation, and adhesion were analyzed by immunohistochemistry. Epithelial resurfacing and vertical proliferation were reduced and delayed with both bioartificial matrices compared with deepidermized dermis; however, no differences in apoptosis, cell differentiation, or basement membrane formation were found. Vertical penetration was greatest on Matriderm, whereas no matrix infiltration was found on Strattice in the first 12 days. Uncompromised horizontal resurfacing was greatest with Strattice but was absent with Matriderm. Strattice showed no stimulatory effect on cellular inflammation. Matrix texture and surface properties governed cellular performance on tissues. Although dense dermal compaction delayed vertical cellular ingrowth for Strattice, it allowed uncompromised horizontal resurfacing. Dense dermal compaction may slow matrix decomposition and result in prolonged biomechanical stability of the graft. Reconstructive surgeons should choose the adequate matrix substitute depending on biomechanical requirements at the recipient site. Strattice may be suitable as a dermal replacement at recipient sites with high mechanical load requirements.

  7. Non-thermal near-infrared exposure photobiomodulates cellular responses to ionizing radiation in human full thickness skin models.

    PubMed

    König, Anke; Zöller, Nadja; Kippenberger, Stefan; Bernd, August; Kaufmann, Roland; Layer, Paul G; Heselich, Anja

    2018-01-01

    Ionizing and near-infrared radiation are both part of the therapeutic spectrum in cancer treatment. During cancer therapy ionizing radiation is typically used for non-invasive reduction of malignant tissue, while near-infrared photobiomodulation is utilized in palliative medical approaches, e.g. for pain reduction or impairment of wound healing. Furthermore, near-infrared is part of the solar wavelength spectrum. A combined exposure of these two irradiation qualities - either intentionally during medical treatment or unintentionally due to solar exposure - is therefore presumable for cancer patients. Several studies in different model organisms and cell cultures show a strong impact of near-infrared pretreatment on ionizing radiation-induced stress response. To investigate the risks of non-thermal near-infrared (NIR) pretreatment in patients, a human in vitro full thickness skin models (FTSM) was evaluated for radiation research. FTSM were pretreated with therapy-relevant doses of NIR followed by X-radiation, and then examined for DNA-double-strand break (DSB) repair, cell proliferation and apoptosis. Double-treated FTSM revealed a clear influence of NIR on X-radiation-induced stress responses in cells in their typical tissue environment. Furthermore, over a 24h time period, double-treated FTSM presented a significant persistence of DSBs, as compared to samples exclusively irradiated by X-rays. In addition, NIR pretreatment inhibited apoptosis induction of integrated fibroblasts, and counteracted the radiation-induced proliferation inhibition of basal keratinocytes. Our work suggests that cancer patients treated with X-rays should be prevented from uncontrolled NIR irradiation. On the other hand, controlled double-treatment could provide an alternative therapy approach, exposing the patient to less radiation. Copyright © 2017. Published by Elsevier B.V.

  8. Articular cartilage repair with recombinant human type II collagen/polylactide scaffold in a preliminary porcine study.

    PubMed

    Muhonen, Virpi; Salonius, Eve; Haaparanta, Anne-Marie; Järvinen, Elina; Paatela, Teemu; Meller, Anna; Hannula, Markus; Björkman, Mimmi; Pyhältö, Tuomo; Ellä, Ville; Vasara, Anna; Töyräs, Juha; Kellomäki, Minna; Kiviranta, Ilkka

    2016-05-01

    The purpose of this study was to investigate the potential of a novel recombinant human type II collagen/polylactide scaffold (rhCo-PLA) in the repair of full-thickness cartilage lesions with autologous chondrocyte implantation technique (ACI). The forming repair tissue was compared to spontaneous healing (spontaneous) and repair with a commercial porcine type I/III collagen membrane (pCo). Domestic pigs (4-month-old, n = 20) were randomized into three study groups and a circular full-thickness chondral lesion with a diameter of 8 mm was created in the right medial femoral condyle. After 3 weeks, the chondral lesions were repaired with either rhCo-PLA or pCo together with autologous chondrocytes, or the lesion was only debrided and left untreated for spontaneous repair. The repair tissue was evaluated 4 months after the second operation. Hyaline cartilage formed most frequently in the rhCo-PLA treatment group. Biomechanically, there was a trend that both treatment groups resulted in better repair tissue than spontaneous healing. Adverse subchondral bone reactions developed less frequently in the spontaneous group (40%) and the rhCo-PLA treated group (50%) than in the pCo control group (100%). However, no statistically significant differences were found between the groups. The novel rhCo-PLA biomaterial showed promising results in this proof-of-concept study, but further studies will be needed in order to determine its effectiveness in articular cartilage repair. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:745-753, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Gellan gum-hyaluronic acid spongy-like hydrogels and cells from adipose tissue synergize promoting neoskin vascularization.

    PubMed

    Cerqueira, Mariana Teixeira; da Silva, Lucília Pereira; Santos, Tírcia Carlos; Pirraco, Rogério Pedro; Correlo, Vítor Manuel; Reis, Rui Luís; Marques, Alexandra Pinto

    2014-11-26

    Currently available substitutes for skin wound healing often result in the formation of nonfunctional neotissue. Thus, urgent care is still needed to promote an effective and complete regeneration. To meet this need, we proposed the assembling of a construct that takes advantage of cell-adhesive gellan gum-hyaluronic acid (GG-HA) spongy-like hydrogels and a powerful cell-machinery obtained from adipose tissue, human adipose stem cells (hASCs), and microvascular endothelial cells (hAMECs). In addition to a cell-adhesive character, GG-HA spongy-like hydrogels overpass limitations of traditional hydrogels, such as reduced physical stability and limited manipulation, due to improved microstructural arrangement characterized by pore wall thickening and increased mean pore size. The proposed constructs combining cellular mediators of the healing process within the spongy-like hydrogels that intend to recapitulate skin matrix aim to promote neoskin vascularization. Stable and off-the-shelf dried GG-HA polymeric networks, rapidly rehydrated at the time of cell seeding then depicting features of both sponges and hydrogels, enabled the natural cell entrapment/encapsulation and attachment supported by cell-polymer interactions. Upon transplantation into mice full-thickness excisional wounds, GG-HA spongy-like hydrogels absorbed the early inflammatory cell infiltrate and led to the formation of a dense granulation tissue. Consequently, spongy-like hydrogel degradation was observed, and progressive wound closure, re-epithelialization, and matrix remodelling was improved in relation to the control condition. More importantly, GG-HA spongy-like hydrogels promoted a superior neovascularization, which was enhanced in the presence of human hAMECs, also found in the formed neovessels. These observations highlight the successful integration of a valuable matrix and prevascularization cues to target angiogenesis/neovascularization in skin full-thickness excisional wounds.

  10. Gelatin/chondroitin sulfate nanofibrous scaffolds for stimulation of wound healing: In-vitro and in-vivo study.

    PubMed

    Pezeshki-Modaress, Mohamad; Mirzadeh, Hamid; Zandi, Mojgan; Rajabi-Zeleti, Sareh; Sodeifi, Niloofar; Aghdami, Nasser; Mofrad, Mohammad R K

    2017-07-01

    In this research, fabrication of gelatin/chondroitin sulfate (GAG) nanofibrous scaffolds using electrospinning technique for skin tissue engineering was studied. The influence of GAG content on chemical, physical, mechanical and biological properties of the scaffolds were investigated. Human dermal fibroblast (HDF) cells were cultured and bioactivity of electrospun gelatin/GAG scaffolds for skin tissue engineering was assayed. Biological results illustrated that HDF cells attached and spread well on gelatin/GAG nanofibrous scaffolds displaying spindle-like shapes and stretching. MTS assay was performed to evaluate the cell proliferation on electrospun gelatin/GAG scaffolds. The results confirmed the influence of GAG content as well as the nanofibrous structure on cell proliferation and attachment of substrates. The gelatin/GAG nanofibrous scaffolds with the desired thickness for in-vivo evaluations were used on the full-thickness wounds. Pathobiological results showed that cell loaded gelatin/GAG scaffolds significantly accelerated wounds healing. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2020-2034, 2017. © 2017 Wiley Periodicals, Inc.

  11. Enhanced cortical thickness measurements for rodent brains via Lagrangian-based RK4 streamline computation

    NASA Astrophysics Data System (ADS)

    Lee, Joohwi; Kim, Sun Hyung; Oguz, Ipek; Styner, Martin

    2016-03-01

    The cortical thickness of the mammalian brain is an important morphological characteristic that can be used to investigate and observe the brain's developmental changes that might be caused by biologically toxic substances such as ethanol or cocaine. Although various cortical thickness analysis methods have been proposed that are applicable for human brain and have developed into well-validated open-source software packages, cortical thickness analysis methods for rodent brains have not yet become as robust and accurate as those designed for human brains. Based on a previously proposed cortical thickness measurement pipeline for rodent brain analysis,1 we present an enhanced cortical thickness pipeline in terms of accuracy and anatomical consistency. First, we propose a Lagrangian-based computational approach in the thickness measurement step in order to minimize local truncation error using the fourth-order Runge-Kutta method. Second, by constructing a line object for each streamline of the thickness measurement, we can visualize the way the thickness is measured and achieve sub-voxel accuracy by performing geometric post-processing. Last, with emphasis on the importance of an anatomically consistent partial differential equation (PDE) boundary map, we propose an automatic PDE boundary map generation algorithm that is specific to rodent brain anatomy, which does not require manual labeling. The results show that the proposed cortical thickness pipeline can produce statistically significant regions that are not observed in the previous cortical thickness analysis pipeline.

  12. Yield Strength Testing in Human Cadaver Nasal Septal Cartilage and L-Strut Constructs.

    PubMed

    Liu, Yuan F; Messinger, Kelton; Inman, Jared C

    2017-01-01

    To our knowledge, yield strength testing in human nasal septal cartilage has not been reported to date. An understanding of the basic mechanics of the nasal septum may help surgeons decide how much of an L-strut to preserve and how much grafting is needed. To determine the factors correlated with yield strength of the cartilaginous nasal septum and to explore the association between L-strut width and thickness in determining yield strength. In an anatomy laboratory, yield strength of rectangular pieces of fresh cadaver nasal septal cartilage was measured, and regression was performed to identify the factors correlated with yield strength. To measure yield strength in L-shaped models, 4 bonded paper L-struts models were constructed for every possible combination of the width and thickness, for a total of 240 models. Mathematical modeling using the resultant data with trend lines and surface fitting was performed to quantify the associations among L-strut width, thickness, and yield strength. The study dates were November 1, 2015, to April 1, 2016. The factors correlated with nasal cartilage yield strength and the associations among L-strut width, thickness, and yield strength in L-shaped models. Among 95 cartilage pieces from 12 human cadavers (mean [SD] age, 67.7 [12.6] years) and 240 constructed L-strut models, L-strut thickness was the only factor correlated with nasal septal cartilage yield strength (coefficient for thickness, 5.54; 95% CI, 4.08-7.00; P < .001), with an adjusted R2 correlation coefficient of 0.37. The mean (SD) yield strength R2 varied with L-strut thickness exponentially (0.93 [0.06]) for set widths, and it varied with L-strut width linearly (0.82 [0.11]) or logarithmically (0.85 [0.17]) for set thicknesses. A 3-dimensional surface model of yield strength with L-strut width and thickness as variables was created using a 2-dimensional gaussian function (adjusted R2 = 0.94). Estimated yield strengths were generated from the model to allow determination of the desired yield strength with different permutations of L-strut width and thickness. In this study of human cadaver nasal septal cartilage, L-strut thickness was significantly associated with yield strength. In a bonded paper L-strut model, L-strut thickness had a more important role in determining yield strength than L-strut width. Surgeons should consider the thickness of potential L-struts when determining the amount of cartilaginous septum to harvest and graft. NA.

  13. Comparison of interleukin 10 homologs on dermal wound healing using a novel human skin ex vivo organ culture model.

    PubMed

    Balaji, Swathi; Moles, Chad M; Bhattacharya, Sukanta S; LeSaint, Maria; Dhamija, Yashu; Le, Louis D; King, Alice; Kidd, Mykia; Bouso, Muhammad F; Shaaban, Aimen; Crombleholme, Timothy M; Bollyky, Paul; Keswani, Sundeep G

    2014-07-01

    Anti-inflammatory cytokine interleukin (IL)-10 has been shown to induce regenerative healing in postnatal wounds. A viral homolog of IL-10 produced by human cytomegalovirus (CMV IL-10) similarly generates potent immunoregulatory effects, but its effects on wound healing have not been investigated. Currently, there are limited cost-effective methods of screening vulnerary therapeutics. Taken together, we aim to develop and validate a novel human ex vivo dermal wound model and hypothesize that CMV IL-10 will enhance dermal wound healing. Full-thickness circular (6-mm) explants were taken from surgical skin samples and 3-mm full-thickness wounds were created. Explants were embedded in collagen I matrix and maintained in specially formulated media with the epidermis at air-liquid interface, and treated with human IL-10 or CMV IL-10 (200 ng/mL). The viability of cultured explants was validated by histology and lactate dehydrogenase (LDH) activity. Epithelial gap, epithelial height, basal keratinocyte migration, vascular endothelial growth factor levels, and neovascularization were measured at days 3 and 7 to determine IL-10 effects on wound healing. Culture explants at day 7 appeared similar to fresh skin in morphology, cell, and vessel density. By day 14, the epidermis separated from the dermis and the cell density diminished. Day 7 wounds appeared viable with advancing epithelial and basal keratinocyte migration with no evidence of necrosis. Cytotoxicity analysis via the quantification of LDH revealed no differences between controls and treated groups. There was a slight increase in the quantity of LDH in media at day 3; however, this decreased at day 5 and continued to decline up to day 21. CMV IL-10 treatment resulted in a significant decrease in the epithelial gap and an increase in epithelial height. There were no differences in the rates of basal keratinocyte migration at day 7 between treated and control groups. Interestingly, human IL-10 increased vascular endothelial growth factor expression and neovascularization compared with controls. The human ex vivo wound model provides a simple and viable design to study dermal wound healing. Both IL-10 homologs demonstrate vulnerary effects. The viral homolog demonstrates enhanced effects on wound closure compared with human IL-10. These data represent a novel tool that can be used to screen therapeutics, such as CMV IL-10, before preclinical studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Cryopreserved Ultra-Thick Human Amniotic Membrane for Conjunctival Surface Reconstruction After Excision of Conjunctival Tumors.

    PubMed

    Tanaka, Thais S; Demirci, Hakan

    2016-04-01

    Cryopreserved ultra-thick human amniotic membrane (AM) is used for glaucoma surgery. We evaluated the use of cryopreserved ultra-thick human AM for conjunctival surface reconstruction after excision of a conjunctival tumor. We retrospectively reviewed the medical records of 28 patients who underwent conjunctival surface reconstruction with cryopreserved ultra-thick human AM after excision of the tumor. The AM was secured to the surrounding conjunctiva and underlying sclera with interrupted 8-0 Vicryl sutures. Clinical data regarding demographics, diagnosis, size and location of conjunctival tumors, patient outcome, and complications were gathered. Of 28 patients, 6 (21.4%) had malignant melanoma, 4 (14.3%) had squamous cell carcinoma, 6 (21.4%) had conjunctival intraepithelial neoplasia, 1 (3.6%) had sebaceous carcinoma, 1 (3.6%) had mucoepidermoid carcinoma, 1 (3.6%) had conjunctival intraepithelial dysplasia, 5 (17.9%) had pterygium, 2 (7.1%) had compound nevus, 1 (3.6%) had a large epithelial inclusion cyst, and 1 (3.6%) patient had a granuloma. The mean area of graft size was 156 ± 120 mm2. Postoperatively, the graft was well tolerated with no failure, discomfort, or dehiscence. During the 17-month mean follow-up, symblepharon, which was clinically nonsignificant, developed in 3 (11%) patients and partial stem cell deficiency was noted in 5 (18%) patients. Cryopreserved ultra-thick human AM is a well-tolerated, effective graft material that is easy to handle. It is a viable alternative for conjunctival surface reconstruction after excision of a conjunctival tumor.

  15. Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study.

    PubMed

    Gartsman, Gary M; Drake, Gregory; Edwards, T Bradley; Elkousy, Hussein A; Hammerman, Steven M; O'Connor, Daniel P; Press, Cyrus M

    2013-11-01

    The purpose of this study was to compare the structural outcomes of a single-row rotator cuff repair and double-row suture bridge fixation after arthroscopic repair of a full-thickness supraspinatus rotator cuff tear. We evaluated with diagnostic ultrasound a consecutive series of ninety shoulders in ninety patients with full-thickness supraspinatus tears at an average of 10 months (range, 6-12) after operation. A single surgeon at a single hospital performed the repairs. Inclusion criteria were full-thickness supraspinatus tears less than 25 mm in their anterior to posterior dimension. Exclusion criteria were prior operations on the shoulder, partial thickness tears, subscapularis tears, infraspinatus tears, combined supraspinatus and infraspinatus repairs and irreparable supraspinatus tears. Forty-three shoulders were repaired with single-row technique and 47 shoulders with double-row suture bridge technique. Postoperative rehabilitation was identical for both groups. Ultrasound criteria for healed repair included visualization of a tendon with normal thickness and length, and a negative compression test. Eighty-three patients were available for ultrasound examination (40 single-row and 43 suture-bridge). Thirty of 40 patients (75%) with single-row repair demonstrated a healed rotator cuff repair compared to 40/43 (93%) patients with suture-bridge repair (P = .024). Arthroscopic double-row suture bridge repair (transosseous equivalent) of an isolated supraspinatus rotator cuff tear resulted in a significantly higher tendon healing rate (as determined by ultrasound examination) when compared to arthroscopic single-row repair. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  16. Reconstructive Surgery in the Thermally Injured Patient

    DTIC Science & Technology

    2012-01-01

    Pedicle flaps • Reconstructive Surgery • Thermal injury • Z-plasties • Skin grafting AN INCREASED NEED FOR RECONSTRUCTIVE SURGERY Reconstruction is a...dermal structure and include the tendency for recurrent contractures. full-thickness skin graft s are usually reserved for reconstructions with...dermatologic surgery: review and update on full- and split thickness skin grafts , free cartilage grafts, and composite grafts. Dermatol Surg 2005;31

  17. Trials Against Conqueror Tanks with Additional Ballistic Protection. Part 2: The Use of Large Hollow-Charge Warheads

    DTIC Science & Technology

    1957-05-01

    4 Ears. Ism could not be examined on account of bilateral chronic suppurative otitis media (C. SO.M.). (The middle ear full of thick pus and drum, if...examined on account of chronic suppurative otitis media (C. S.0. K.). (Middle ear full of thick ps.) Would have survived. Driver’s Seat Upper Rabbit

  18. Enamel thickness variation of deciduous first and second upper molars in modern humans and Neanderthals.

    PubMed

    Fornai, Cinzia; Benazzi, Stefano; Svoboda, Jiří; Pap, Ildikó; Harvati, Katerina; Weber, Gerhard W

    2014-11-01

    Enamel thickness and dental tissue proportions have been recognized as effective taxonomic discriminators between Neanderthal and modern humans teeth. However, most of the research on this topic focused on permanent teeth, and little information is available for the deciduous dentition. Moreover, although worn teeth are more frequently found than unworn teeth, published data for worn teeth are scarce and methods for the assessment of their enamel thickness need to be developed. Here, we addressed this issue by studying the 2D average enamel thickness (AET) and 2D relative enamel thickness (RET) of Neanderthal and modern humans unworn to moderately worn upper first deciduous molars (dm(1)s) and upper second deciduous molars (dm(2)s). In particular, we used 3D μCT data to investigate the mesial section for dm(1)s and both mesial and buccal sections for dm(2)s. Our results confirmed previous findings of an Neanderthal derived condition of thin enamel, and thinner enamel in dm(1)s than dm(2)s in both Neanderthal and modern humans. We demonstrated that the Neanderthal 2D RET indices are significantly lower than those of modern humans at similar wear stages in both dm(1)s and dm(2)s (p < 0.05). The discriminant analysis showed that using 2D RET from dm(1) and dm(2) sections at different wear stages up to 93% of the individuals are correctly classified. Moreover, we showed that the dm(2) buccal sections, although non-conventionally used, might have an advantage on mesial sections since they distinguish as well as mesial sections but tend to be less worn. Therefore, the 2D analysis of enamel thickness is suggested as a means for taxonomic discrimination between modern humans and Neanderthal unworn to moderately worn upper deciduous molars. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Alternative complement pathway activation increases mortality in a model of burn injury in mice.

    PubMed Central

    Gelfand, J A; Donelan, M; Hawiger, A; Burke, J F

    1982-01-01

    We have studied the role of the complement system in burn injury in an experimental model in mice. A 25% body surface area, full-thickness scald wound was produced in anesthetized animals. Massive activation of the alternative complement pathway, but not the classical pathway, was seen. This activation was associated with the generation of neutrophil aggregating activity in the plasma, neutrophil aggregates in the lungs, increased pulmonary vascular permeability, and increased lung edema formation. Decomplementation with cobra venom factor (CVF) or genetic C5 deficiency diminished these pathologic changes, and CVF pretreatment substantially reduced burn mortality in the first 24 h. Preliminary data show that human burn patients have a similar pattern of complement activation involving predominantly the alternative pathway, indicating the possible relevance of the murine model to human disease. Images PMID:7174787

  20. The Genetic Association Between Neocortical Volume and General Cognitive Ability Is Driven by Global Surface Area Rather Than Thickness.

    PubMed

    Vuoksimaa, Eero; Panizzon, Matthew S; Chen, Chi-Hua; Fiecas, Mark; Eyler, Lisa T; Fennema-Notestine, Christine; Hagler, Donald J; Fischl, Bruce; Franz, Carol E; Jak, Amy; Lyons, Michael J; Neale, Michael C; Rinker, Daniel A; Thompson, Wesley K; Tsuang, Ming T; Dale, Anders M; Kremen, William S

    2015-08-01

    Total gray matter volume is associated with general cognitive ability (GCA), an association mediated by genetic factors. It is expectable that total neocortical volume should be similarly associated with GCA. Neocortical volume is the product of thickness and surface area, but global thickness and surface area are unrelated phenotypically and genetically in humans. The nature of the genetic association between GCA and either of these 2 cortical dimensions has not been examined. Humans possess greater cognitive capacity than other species, and surface area increases appear to be the primary driver of the increased size of the human cortex. Thus, we expected neocortical surface area to be more strongly associated with cognition than thickness. Using multivariate genetic analysis in 515 middle-aged twins, we demonstrated that both the phenotypic and genetic associations between neocortical volume and GCA are driven primarily by surface area rather than thickness. Results were generally similar for each of 4 specific cognitive abilities that comprised the GCA measure. Our results suggest that emphasis on neocortical surface area, rather than thickness, could be more fruitful for elucidating neocortical-GCA associations and identifying specific genes underlying those associations. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  1. Testing functional and morphological interpretations of enamel thickness along the deciduous tooth row in human children.

    PubMed

    Mahoney, Patrick

    2013-08-01

    The significance of a gradient in enamel thickness along the human permanent molar row has been debated in the literature. Some attribute increased enamel thickness from first to third molars to greater bite force during chewing. Others argue that thicker third molar enamel relates to a smaller crown size facilitated by a reduced dentin component. Thus, differences in morphology, not function, explains enamel thickness. This study draws on these different interpretive models to assess enamel thickness along the entire human deciduous tooth row. Average enamel thickness (AET), the area and proportion of crown enamel and dentin, and a crown size proxy are calculated for incisors, canines, and molars. Allometric scaling relationships are assessed within each tooth class, and then comparisons are undertaken along the row. Generally, AET was correlated with crown size and scaled with isometry, except for second molars which scaled with positive allometry. Mean AET increased along the row and was greater on molars, where bite forces are reported to be higher. Second molars combined the largest crown size with the thickest enamel and the smallest proportion of dentin, which is consistent with a reduction in the potential for cusp fracture under high bite forces. Resistance to wear may also account for some enamel thickness variation between tooth classes. Dental reduction did not explain the trend in AET from central to lateral incisors, or from first to second molars. The gradient in AET along the deciduous tooth row is partly consistent with a functional interpretation of enamel thickness. Copyright © 2013 Wiley Periodicals, Inc.

  2. Monoblock Expanded Full-thickness Graft for Resurfacing of the Burned Face in Young Patients.

    PubMed

    Allam, A M; El Khalek, A E A; Mustafa, W; Zayed, E

    2007-12-31

    It has been emphasized by many authors that to obtain better aesthetic results in a burned facial area to be resurfaced - if it extends into more than one aesthetic territory - the units involved should be combined into a single large composite unit allowing the largest possible skin graft to be used. Unfortunately, the donor site for full-thickness grafts is limited in young patients and hence tissue expansion is used. A monoblock expanded full-thickness skin graft for facial resurfacing after post-burn sequelae excision was used in 12 young patients after expansion of the superolateral aspect of the buttock. Females made up the majority of the patients (75%) and the ages ranged between 8 and 18 yr. The operating time was 3-3.5 hours, in two sessions. Post-operatively, we recorded partial graft necrosis in two cases (16.7%) and infection in one (8.3%), and some minor donor-site-related complications were reported, such as haematoma in one patient (8.3%), wound infection in one patient (8.3%), and wide scarring in two patients (16.7%). At follow-up, eight of the patients (66.7%) were satisfied with their new facial look as the mask effect of facial scarring had been overcome. With monoblock expanded full-thickness graft we were able to resurface the face in nine cases (75%). A second complementary procedure to reconstruct the eyebrows or reshape the nose was required in two cases (16.7%). We concluded that the monoblock expanded full-thickness graft was a suitable solution for limitation of the donor site in young patients, as the resulting wound could be closed primarily with a scar that could be concealed by the underwear, with lim.

  3. Monoblock Expanded Full-thickness Graft for Resurfacing of the Burned Face in Young Patients

    PubMed Central

    Allam, A.M.; El Khalek, A.E.A.; Mustafa, W.; Zayed, E.

    2007-01-01

    Summary It has been emphasized by many authors that to obtain better aesthetic results in a burned facial area to be resurfaced - if it extends into more than one aesthetic territory - the units involved should be combined into a single large composite unit allowing the largest possible skin graft to be used. Unfortunately, the donor site for full-thickness grafts is limited in young patients and hence tissue expansion is used. A monoblock expanded full-thickness skin graft for facial resurfacing after post-burn sequelae excision was used in 12 young patients after expansion of the superolateral aspect of the buttock. Females made up the majority of the patients (75%) and the ages ranged between 8 and 18 yr. The operating time was 3-3.5 hours, in two sessions. Post-operatively, we recorded partial graft necrosis in two cases (16.7%) and infection in one (8.3%), and some minor donor-site-related complications were reported, such as haematoma in one patient (8.3%), wound infection in one patient (8.3%), and wide scarring in two patients (16.7%). At follow-up, eight of the patients (66.7%) were satisfied with their new facial look as the mask effect of facial scarring had been overcome. With monoblock expanded full-thickness graft we were able to resurface the face in nine cases (75%). A second complementary procedure to reconstruct the eyebrows or reshape the nose was required in two cases (16.7%). We concluded that the monoblock expanded full-thickness graft was a suitable solution for limitation of the donor site in young patients, as the resulting wound could be closed primarily with a scar that could be concealed by the underwear, with lim. PMID:21991093

  4. Application of indocyanine green-fluorescence imaging to full-thickness cholecystectomy.

    PubMed

    Morita, Kiyomi; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Shimizu, Atsushi; Yamamoto, Satoshi; Takemura, Nobuyuki; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-05-01

    Fluorescence imaging using indocyanine green (ICG) has recently been applied to laparoscopic surgery to identify cancerous tissues, lymph nodes, and vascular anatomy. Here we report the application of ICG-fluorescence imaging to visualize the boundary between the liver and subserosal tissues of the gallbladder during laparoscopic full-thickness cholecystectomy. A patient with a potentially malignant gallbladder lesion was administered 2.5-mg intravenous ICG just before laparoscopic full-thickness cholecystectomy. Intraoperative fluorescence imaging enabled the real-time delineation of both extrahepatic bile duct anatomy and hepatic parenchyma throughout the procedure, which resulted in complete removal of subserosal tissues between liver and gallbladder. Safe and feasible ICG-fluorescence imaging can be widely applied to laparoscopic hepatobiliary surgery by utilizing a biliary excretion property of ICG. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  5. Accelerated healing of full-thickness wounds by genipin-crosslinked silk sericin/PVA scaffolds.

    PubMed

    Aramwit, Pornanong; Siritienthong, Tippawan; Srichana, Teerapol; Ratanavaraporn, Juthamas

    2013-01-01

    Silk sericin has recently been studied for its advantageous biological properties, including its ability to promote wound healing. This study developed a delivery system to accelerate the healing of full-thickness wounds. Three-dimensional scaffolds were fabricated from poly(vinyl alcohol) (PVA), glycerin (as a plasticizer) and genipin (as a crosslinking agent), with or without sericin. The physical and biological properties of the genipin-crosslinked sericin/PVA scaffolds were investigated and compared with those of scaffolds without sericin. The genipin-crosslinked sericin/PVA scaffolds exhibited a higher compressive modulus and greater swelling in water than the scaffolds without sericin. Sericin also exhibited controlled release from the scaffolds. The genipin-crosslinked sericin/PVA scaffolds promoted the attachment and proliferation of L929 mouse fibroblasts. After application to full-thickness rat wounds, the wounds treated with genipin-crosslinked sericin/PVA scaffolds showed a significantly greater reduction in wound size, collagen formation and epithelialization compared with the control scaffolds without sericin but lower numbers of macrophages and multinucleated giant cells. These results indicate that the delivery of sericin from the novel genipin-crosslinked scaffolds efficiently healed the wound. Therefore, these genipin-crosslinked sericin/PVA scaffolds represent a promising candidate for the accelerated healing of full-thickness wounds. Copyright © 2013 S. Karger AG, Basel.

  6. Full thickness facial burns: Outcomes following orofacial rehabilitation.

    PubMed

    Clayton, N A; Ward, E C; Maitz, P K M

    2015-11-01

    To document orofacial rehabilitation and outcomes after full thickness orofacial burn. Participants included 12 consecutive patients presenting with full thickness orofacial burns. A group of 120 age-matched healthy participants was recruited for normative comparison. Non-surgical exercise was initiated within 48 h of admission and continued until wounds had healed, circumoral scar tissue had stabilised and functional goals were achieved to the best of the patient's ability. Outcomes were documented using vertical and horizontal mouth opening measures at start and end of treatment and therapy duration was recorded. At commencement of treatment, participants had significantly (p<0.001) reduced vertical and horizontal mouth opening range compared to controls. Average duration of orofacial contracture management was 550 days, with half requiring >2 years rehabilitation. By end of treatment, significant (p<0.01) positive improvement in vertical and horizontal mouth opening had been achieved, however measures had returned to lower limits of normal function and remained significantly (p<0.05) reduced compared to the control group. This study demonstrates that although positive gains can be achieved through non-surgical exercise after full thickness burn, the duration of rehabilitation is considerable and some degree of long term loss in functional mouth opening remains. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  7. Uninduced adipose-derived stem cells repair the defect of full-thickness hyaline cartilage.

    PubMed

    Zhang, Hai-Ning; Li, Lei; Leng, Ping; Wang, Ying-Zhen; Lv, Cheng-Yu

    2009-04-01

    To testify the effect of the stem cells derived from the widely distributed fat tissue on repairing full-thickness hyaline cartilage defects. Adipose-derived stem cells (ADSCs) were derived from adipose tissue and cultured in vitro. Twenty-seven New Zealand white rabbits were divided into three groups randomly. The cultured ADSCs mixed with calcium alginate gel were used to fill the full-thickness hyaline cartilage defects created at the patellafemoral joint, and the defects repaired with gel or without treatment served as control groups. After 4, 8 and 12 weeks, the reconstructed tissue was evaluated macroscopically and microscopically. Histological analysis and qualitative scoring were also performed to detect the outcome. Full thickness hyaline cartilage defects were repaired completely with ADSCs-derived tissue. The result was better in ADSCs group than the control ones. The microstructure of reconstructed tissue with ADSCs was similar to that of hyaline cartilage and contained more cells and regular matrix fibers, being better than other groups. Plenty of collagen fibers around cells could be seen under transmission electron microscopy. Statistical analysis revealed a significant difference in comparison with other groups at each time point (t equal to 4.360, P less than 0.01). These results indicate that stem cells derived from mature adipose without induction possess the ability to repair cartilage defects.

  8. Clinical potential of a silk sericin-releasing bioactive wound dressing for the treatment of split-thickness skin graft donor sites.

    PubMed

    Siritientong, Tippawan; Angspatt, Apichai; Ratanavaraporn, Juthamas; Aramwit, Pornanong

    2014-01-01

    An ethyl alcohol-precipitated silk sericin/PVA scaffold that controlled the release of silk sericin was previously developed and applied for the treatment of full-thickness wounds in rats and demonstrated efficient healing. In this study, we aimed to further evaluate the clinical potential of this scaffold, hereafter called "silk sericin-releasing wound dressing", for the treatment of split-thickness skin graft donor sites by comparison with the clinically available wound dressing known as "Bactigras®". In vitro characterization and in vivo evaluation for safety of the wound dressings were performed. A clinical trial of the wound dressings was conducted according to standard protocols. The sericin released from the wound dressing was not toxic to HaCat human keratinocytes. A peel test indicated that the silk sericin-releasing wound dressing was less adhesive than Bactigras®, potentially reducing trauma and the risk of repeated injury upon removal. There was no evidence of skin irritation upon treatment with either wound dressing. When tested in patients with split-thickness skin graft donor sites, the wounds treated with the silk sericin-releasing wound dressing exhibited complete healing at 12 ± 5.0 days, whereas those treated with Bactigras® were completely healed at 14 ± 5.2 days (p = 1.99 × 10(-4)). In addition, treatment with the silk sericin-releasing wound dressing significantly reduced pain compared with Bactigras® particularly during the first 4 postoperative days (p = 2.70 × 10(-5) on day 1). We introduce this novel silk sericin-releasing wound dressing as an alternative treatment for split-thickness skin graft donor sites.

  9. The Relevance of Hyperbaric Oxygen to Combat Medicine

    DTIC Science & Technology

    2001-06-01

    poorly vascularized tissue, infected tissue, osteomyelitis, and irradiated tissue4𔃿. In full thickness, skin grafts and flaps, hyperbaric oxygen has...required for wound closure12ൕ" 4. The salvaging effect of hyperbaric oxygen on failing flaps and full thickness skin grafts has been demonstrated... skin grafts , Lancet 1967 Apr 22: 868-87 1. 7 McFarlane, R. M., Wermuth, R. E., The use of hyperbaric oxygen to prevent necrosis in experimental

  10. Acute corneal hydrops mimicking full thickness perforation.

    PubMed

    Ch'ng, S W; Pillai, M B; Aazeem, S; Tu, K L

    2012-05-11

    A 26-year-old Caucasian female with keratoconus presented with an acutely painful and red left eye. Visual acuity on presentation was 3/60. Slit lamp examination revealed localised Descemet's membrane break with iris partially plugging it. There was a bulging stromal cyst which would intermittently flatten and reform. The appearance when the cyst was flattened mimicked a full thickness corneal perforation. However, no obvious overlying epithelial defect was detected and an intermittent leakage through micro-perforations in the corneal epithelium was the probable cause of the variable appearance. The anterior chamber reformed and iris plug freed following an insertion of a bandage contact lens and taped eyelid. On follow-up, the Descement's membrane had healed with visual acuity improving to 6/18. Our case illustrates the importance of identifying corneal hydrops mimicking a full thickness perforation as conservative management has a greater chance of recovery.

  11. Keratoprosthesis: preliminary results of an artificial corneal button as a full-thickness implant in the rabbit model.

    PubMed

    Hicks, C R; Chirila, T V; Dalton, P D; Clayton, A B; Vijayasekaran, S; Crawford, G J; Constable, I J

    1996-08-01

    To develop a prototype artificial cornea and evaluate it in the rabbit model. Hydrogel core-and-skirt keratoprostheses were made and were inserted as full-thickness implants covered with conjunctival flaps in the right eyes of eight rabbits. Peroperative complications related to inadequate mechanical strength led to failure in the early postoperative period in three animals, one was euthanased for an unrelated reason and the remaining four have been successful for up to 16 weeks' follow-up. Full-thickness implantation of an artificial cornea, analogous to penetrating keratoplasty, has been achieved in the rabbit model. Histological findings confirm that integration of the prosthesis with host tissue occurs. The main complications encountered in this preliminary series were related to inadequate strength of the sponge skirt of this prototype device. Work in our laboratories is now concentrated upon improving the mechanical qualities of the hydrogel skirt and on the enhancement of biointegration.

  12. Full-thickness small intestine necrosis with midgut volvulus, distributed in a patchy fashion, is reversible with moderate blood flow: resumption of normal function to non-viable intestine.

    PubMed

    Amano, Hizuru; Uchida, Hiroo; Kawashima, Hiroshi; Tanaka, Yujiro; Kishimoto, Hiroshi

    2014-08-01

    Midgut volvulus is a highly life-threatening condition that carries a high risk of short gut syndrome. We report a case of catastrophic neonatal midgut volvulus in which second-look laparotomy revealed apparently non-viable remnant small intestine but with a moderate blood supply. Full-thickness small intestine necrosis was distributed in a patchy fashion, with non-viable and necrotic areas distributed so widely that no portion of the intestine could be resected. A section of full-thickness necrotic intestine preserved at surgery was able to regenerate, and normal function was restored over a period of 1 month. This case indicated that intestinal resumption may be dependent on blood flow. Even when intestinal viability is questionable, preservation enables the chance of regeneration if moderate blood flow is present.

  13. Combined bilateral hatchet and nasolabial advancement flaps for a large defect of the lower lip.

    PubMed

    Makiguchi, Takaya; Yokoo, Satoshi; Miyazaki, Hidetaka; Soda, Takashi; Terashi, Hiroto

    2013-11-01

    A large full-thickness defect of the lower lip is difficult to reconstruct. Preservation of eating and speaking functions based on maintenance of oral sphincter and muscle function, sensation, and the oral aperture are the basic aims. It is also important to achieve a good aesthetic appearance. Here, we describe a new procedure using combined bilateral hatchet and nasolabial advancement flaps for a large full-thickness defect of the lower lip. The aim of use of the hatchet flap is to make a natural curve from the mentolabial fold to the mental protuberance using the "dog ear" resulting from suturing medially advanced bilateral hatchet flaps and to preserve a more certain blood supply to the medial edge of the flap. Our results indicate that the procedure using combined bilateral hatchet flaps and nasolabial flaps is useful for a U-shaped large full-thickness defect, with good functional and aesthetic outcomes.

  14. Biomimetic Delivery of Keratinocyte Growth Factor upon Cellular Demand for Accelerated Wound Healing in Vitro and in Vivo

    PubMed Central

    Geer, David J.; Swartz, Daniel D.; Andreadis, Stelios T.

    2005-01-01

    Exogenous keratinocyte growth factor (KGF) significantly enhances wound healing, but its use is hampered by a short biological half-life and lack of tissue selectivity. We used a biomimetic approach to achieve cell-controlled delivery of KGF by covalently attaching a fluorescent matrix-binding peptide that contained two domains: one recognized by factor XIII and the other by plasmin. Modified KGF was incorporated into the fibrin matrix at high concentration in a factor XIII-dependent manner. Cell-mediated activation of plasminogen to plasmin degraded the fibrin matrix and cleaved the peptides, releasing active KGF to the local microenvironment and enhancing epithelial cell proliferation and migration. To demonstrate in vivo effectiveness, we used a hybrid model of wound healing that involved transplanting human bioengineered skin onto athymic mice. At 6 weeks after grafting, the transplanted tissues underwent full thickness wounding and treatment with fibrin gels containing bound KGF. In contrast to topical KGF, fibrin-bound KGF persisted in the wounds for several days and was released gradually, resulting in significantly enhanced wound closure. A fibrinolytic inhibitor prevented this healing, indicating the requirement for cell-mediated fibrin degradation to release KGF. In conclusion, this biomimetic approach of localized, cell-controlled delivery of growth factors may accelerate healing of large full-thickness wounds and chronic wounds that are notoriously difficult to heal. PMID:16314471

  15. MACF1 Overexpression by Transfecting the 21 kbp Large Plasmid PEGFP-C1A-ACF7 Promotes Osteoblast Differentiation and Bone Formation.

    PubMed

    Zhang, Yan; Yin, Chong; Hu, Lifang; Chen, Zhihao; Zhao, Fan; Li, Dijie; Ma, Jianhua; Ma, Xiaoli; Su, Peihong; Qiu, Wuxia; Yang, Chaofei; Wang, Pai; Li, Siyu; Zhang, Ge; Wang, Liping; Qian, Airong; Xian, Cory J

    2018-02-01

    Microtubule actin crosslinking factor 1 (MACF1) is a large spectraplakin protein known to have crucial roles in regulating cytoskeletal dynamics, cell migration, growth, and differentiation. However, its role and action mechanism in bone remain unclear. The present study investigated optimal conditions for effective transfection of the large plasmid PEGFP-C1A-ACF7 (∼21 kbp) containing full-length human MACF1 cDNA, as well as the potential role of MACF1 in bone formation. To enhance MACF1 expression, the plasmid was transfected into osteogenic cells by electroporation in vitro and into mouse calvaria with nanoparticles. Then, transfection efficiency, osteogenic marker expression, calvarial thickness, and bone formation were analyzed. Notably, MACF1 overexpression triggered a drastic increase in osteogenic gene expression, alkaline phosphatase activity, and matrix mineralization in vitro. Mouse calvarial thickness, mineral apposition rate, and osteogenic marker protein expression were significantly enhanced by local transfection. In addition, MACF1 overexpression promoted β-catenin expression and signaling. In conclusion, MACF1 overexpression by transfecting the large plasmid containing full-length MACF1 cDNA promotes osteoblast differentiation and bone formation via β-catenin signaling. Current data will provide useful experimental parameters for the transfection of large plasmids and a novel strategy based on promoting bone formation for prevention and therapy of bone disorders.

  16. Biodegradable lysine-derived polyurethane scaffolds promote healing in a porcine full-thickness excisional wound model

    PubMed Central

    Adolph, Elizabeth J.; Pollins, Alonda C.; Cardwell, Nancy L.; Davidson, Jeffrey M.; Guelcher, Scott A.; Nanney, Lillian B.

    2014-01-01

    Lysine-derived polyurethane scaffolds (LTI-PUR) support cutaneous wound healing in loose-skinned small animal models. Due to the physiological and anatomical similarities of human and pig skin we investigated the capacity of LTI-PUR scaffolds to support wound healing in a porcine excisional wound model. Modifications to scaffold design included the addition of carboxymethylcellulose (CMC) as a porogen to increase interconnectivity and an additional plasma treatment (Plasma) to decrease surface hydrophobicity. All LTI-PUR scaffold and formulations supported cellular infiltration and were biodegradable. At 15 days, CMC and Plasma scaffolds simulated increased macrophages more so than LTI PUR or no treatment. This response was consistent with macrophage-mediated oxidative degradation of the lysine component of the scaffolds. Cell proliferation was similar in control and scaffold treated wounds at 8 and 15 days. Neither apoptosis nor blood vessel area density showed significant differences in the presence of any of the scaffold variations compared to untreated wounds, providing further evidence that these synthetic biomaterials had no adverse effects on those pivotal wound healing processes. During the critical phase of granulation tissue formation in full thickness porcine excisional wounds, LTI-PUR scaffolds supported tissue infiltration, while undergoing biodegradation. Modifications to scaffold fabrication modify the reparative process. This study emphasizes the biocompatibility and favorable cellular responses of PUR scaffolding formulations in a clinically relevant animal model. PMID:25290884

  17. Effect of Platelet Rich Plasma Combined with Chitosan Biodegradable Film on Full-Thickness Wound Healing in Rat Model

    PubMed Central

    Mohammadi, Rahim; Mehrtash, Moein; Mehrtash, Moeid; Hassani, Nava; Hassanpour, Ali

    2016-01-01

    Objective: To assess the effects of platelet rich plasma (PRP) with chitosan biodegradable film on full thickness wound healing in rat. Methods: This was an experimental study being performed in 2015 during a 4-month period. Twenty-four male white Wistar rats were divided into four groups of 12 rats each, randomly: Control group (SHAM) with creation of wounds and no treatment, PRP group with creation of wounds and application of one milliliter PRP, Chitosan group (CHIT) with dressing the wound with chitosan and CHIT/PRP group with application of one mL PRPand dressing the wound with chitosan. The wounds were created by cutting healthy skin.Wound size was measured on 6, 9, 12, 15, 18 and 21 post surgery and was compared between groups. Results: Reduction in wound area, hydroxyproline contents and biomechanical parametersindicated there was significant difference (p=0.001) between group CHIT/PRP and other groups. Biomechanical testing was performed on day 9 post surgery in incisional model. Quantitative histological studies and mean rank of the qualitative studies demonstrated that there was significant difference (p<0.001) between group CHIT/PRP and other groups. Conclusion: PRP with chitosan have beneficial effects on wounds repair and could be suggested for treating various types of wounds in animals and human being. PMID:27162924

  18. Noncontact optical measurement of lens capsule thickness ex vivo

    NASA Astrophysics Data System (ADS)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  19. Evaluation of cultured human dermal- and dermo-epidermal substitutes focusing on extracellular matrix components: Comparison of protein and RNA analysis.

    PubMed

    Oostendorp, Corien; Meyer, Sarah; Sobrio, Monia; van Arendonk, Joyce; Reichmann, Ernst; Daamen, Willeke F; van Kuppevelt, Toin H

    2017-05-01

    Treatment of full-thickness skin defects with split-thickness skin grafts is generally associated with contraction and scar formation and cellular skin substitutes have been developed to improve skin regeneration. The evaluation of cultured skin substitutes is generally based on qualitative parameters focusing on histology. In this study we focused on quantitative evaluation to provide a template for comparison of human bio-engineered skin substitutes between clinical and/or research centers, and to supplement histological data. We focused on extracellular matrix proteins since these components play an important role in skin regeneration. As a model we analyzed the human dermal substitute denovoDerm and the dermo-epidermal skin substitute denovoSkin. The quantification of the extracellular matrix proteins type III collagen and laminin 5 in tissue homogenates using western blotting analysis and ELISA was not successful. The same was true for assaying lysyl oxidase, an enzyme involved in crosslinking of matrix molecules. As an alternative, gene expression levels were measured using qPCR. Various RNA isolation procedures were probed. The gene expression profile for specific dermal and epidermal genes could be measured reliably and reproducibly. Differences caused by changes in the cell culture conditions could easily be detected. The number of cells in the skin substitutes was measured using the PicoGreen dsDNA assay, which was found highly quantitative and reproducible. The (dis) advantages of assays used for quantitative evaluation of skin substitutes are discussed. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  20. SUNLIGHT AS A FACTOR INFLUENCING THE THICKNESS OF EPIDERMIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freeman, R.G.; Cockerell, E.G.; Armstrong, J.

    Measurements of epidermal thickness were made on 28 human volunteers. Shortening of rete ridges was found in exposed white skin but was not seen in unexposed skin nor in Negroes. Differences in epidermal thickness related to age, sex, complexion, or variation in sunlight exposure were not statistically significant. (P.C.H.)

  1. Relationship of Tear Size and Location to Fatty Degeneration of the Rotator Cuff

    PubMed Central

    Kim, H. Mike; Dahiya, Nirvikar; Teefey, Sharlene A.; Keener, Jay D.; Galatz, Leesa M.; Yamaguchi, Ken

    2010-01-01

    Background: Fatty degeneration of the rotator cuff muscles may have detrimental effects on both anatomical and functional outcomes following shoulder surgery. The purpose of this study was to investigate the relationship between tear geometry and muscle fatty degeneration in shoulders with a deficient rotator cuff. Methods: Ultrasonograms of both shoulders of 262 patients were reviewed to assess the type of rotator cuff tear and fatty degeneration in the supraspinatus and infraspinatus muscles. The 251 shoulders with a full-thickness tear underwent further evaluation for tear size and location. The relationship of tear size and location to fatty degeneration of the supraspinatus and infraspinatus muscles was investigated with use of statistical comparisons and regression models. Results: Fatty degeneration was found almost exclusively in shoulders with a full-thickness rotator cuff tear. Of the 251 shoulders with a full-thickness tear, eighty-seven (34.7%) had fatty degeneration in either the supraspinatus or infraspinatus, or both. Eighty-two (32.7%) of the 251 full-thickness tears had a distance of 0 mm between the biceps tendon and anterior margin of the tear. Ninety percent of the full-thickness tears with fatty degeneration in both muscles had a distance of 0 mm posterior from the biceps, whereas only 9% of those without fatty degeneration had a distance of 0 mm. Tears with fatty degeneration had significantly greater width and length than those without fatty degeneration (p < 0.0001). Tears with fatty degeneration had a significantly shorter distance posterior from the biceps than those without fatty degeneration (p < 0.0001). The distance posterior from the biceps was found to be the most important predictor for supraspinatus fatty degeneration, whereas tear width and length were found to be the most important predictors for infraspinatus fatty degeneration. Conclusions: Fatty degeneration of the rotator cuff muscles is closely associated with tear size and location. The finding of this study suggests that the integrity of the anterior supraspinatus tendon is important to the development of fatty degeneration. Patients with full-thickness tears that extend through this area may benefit from earlier surgical intervention if fatty degeneration has not already occurred. Additionally, the findings suggest the importance of secure fixation and healing of the anterior aspect of the supraspinatus with surgical repair. PMID:20360505

  2. Characteristics of peripapillary retinal nerve fiber layer in preterm children.

    PubMed

    Wang, Jingyun; Spencer, Rand; Leffler, Joel N; Birch, Eileen E

    2012-05-01

    To examine quantitatively characteristics of the peripapillary retinal nerve fiber layer (RNFL) in preterm children using Fourier-domain optical coherence tomography (FD-OCT). Prospective cross-sectional study. A 3-mm high-resolution FD-OCT peripapillary RNFL circular scan centered on the optic disc was obtained from right eyes of 25 preterm children (10.6 ± 3.7 years old, 8 preterm and 17 with regressed retinopathy of prematurity with normal-appearing posterior poles) and 54 full-term controls (9.8 ± 3.2 years old). Images were analyzed using Spectralis FD-OCT software to obtain average thickness measurements for 6 sectors (temporal superior, temporal, temporal inferior, nasal inferior, nasal, nasal superior), and the global average. The RNFL global average for preterm children was 8% thinner than for full-term controls. In the preterm group, peripapillary RNFL thickness on the temporal side of the disc was 6% thicker than in full-term controls, while all other peripapillary RNFL sectors were 9% to 13% thinner. In the preterm group, temporal sector peripapillary RNFL thickness was correlated with gestational age (r = -0.47, P < .001), with foveal center total thickness (r = 0.48, P = .008, 1-tailed), and with visual acuity (r = 0.42; P = .026, 1-tailed). The significantly thinner RNFL global average for preterm children suggests that prematurity is associated with subclinical optic nerve hypoplasia. Significant correlations between temporal sector RNFL thickness and both the foveal thickness and visual acuity suggest that the peripapillary RNFL is related to abnormalities in macular development as a result of preterm birth. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Healing rate and autoimmune safety of full-thickness wounds treated with fish skin acellular dermal matrix versus porcine small-intestine submucosa: a noninferiority study.

    PubMed

    Baldursson, Baldur Tumi; Kjartansson, Hilmar; Konrádsdóttir, Fífa; Gudnason, Palmar; Sigurjonsson, Gudmundur F; Lund, Sigrún Helga

    2015-03-01

    A novel product, the fish skin acellular dermal matrix (ADM) has recently been introduced into the family of biological materials for the treatment of wounds. Hitherto, these products have been produced from the organs of livestock. A noninferiority test was used to compare the effect of fish skin ADM against porcine small-intestine submucosa extracellular matrix in the healing of 162 full-thickness 4-mm wounds on the forearm of 81 volunteers. The fish skin product was noninferior at the primary end point, healing at 28 days. Furthermore, the wounds treated with fish skin acellular matrix healed significantly faster. These results might give the fish skin ADM an advantage because of its environmental neutrality when compared with livestock-derived products. The study results on these acute full-thickness wounds might apply for diabetic foot ulcers and other chronic full-thickness wounds, and the shorter healing time for the fish skin-treated group could influence treatment decisions. To test the autoimmune reactivity of the fish skin, the participants were tested with the following ELISA (enzyme-linked immunosorbent assay) tests: RF, ANA, ENA, anti ds-DNA, ANCA, anti-CCP, and anticollagen I and II. These showed no reactivity. The results demonstrate the claims of safety and efficacy of fish skin ADM for wound care. © The Author(s) 2015.

  4. Bilateral superiorly based full-thickness nasolabial island flaps for closure of residual anterior palatal fistulas in an unoperated elderly patient.

    PubMed

    Erçöçen, A R; Yilmaz, S; Saydam, M

    2003-01-01

    Unoperated bilateral complete cleft lip and palate in an adult or elderly patient is seen rarely, and the existence of unoperated clefts is a result of unfavorable economic and social circumstances. We report an unoperated 65-year-old patient with bilateral complete cleft lip and palate and present our preference for the surgical management. Repair of the bilateral complete cleft lip and palate was successfully carried out using straight-line closure for the bilateral cleft lip and two-flap pushback palatoplasty with superiorly based lateral port control pharyngeal flap for the wide cleft palate at the first stage, and large residual anterior palatal fistulas were closed using bilateral superiorly based (retrograde flow) full-thickness nasolabial island flaps at the second stage. To our knowledge based on a review of the literature, this is the first report of an elderly patient with bilateral complete cleft lip and palate and the first application of bilateral superiorly based (retrograde flow) full-thickness nasolabial island flaps for closure of large residual anterior palatal fistulas or alveolar clefts. The bilateral superiorly based (retrograde flow) full-thickness nasolabial island flap may be a good solution in large anterior palatal defects using unilaterally or bilaterally in a single stage with minimal donor site morbidity, in which there is not enough tissue for local repair or if previous attempts are unsuccessful.

  5. Tissue-engineered oral mucosa grafts for intraoral lining reconstruction of the maxilla and mandible with a fibula flap.

    PubMed

    Sieira Gil, Ramón; Pagés, Carles Martí; Díez, Eloy García; Llames, Sara; Fuertes, Ada Ferrer; Vilagran, Jesús Lopez

    2015-01-01

    Many types of soft tissue grafts have been used for grafting or prelaminating bone flaps for intraoral lining reconstruction. The best results are achieved when prelaminating free flaps with mucosal grafts. We suggest a new approach to obtain keratinized mucosa over a fibula flap using full-thickness, engineered, autologous oral mucosa. We report on a pilot study for grafting fibula flaps for mandibular and maxilla reconstruction with full-thickness tissue-engineered autologous oral mucosa. We describe 2 different techniques: prelaminating the fibula flap and second-stage grafting of the fibula after mandibular reconstruction. Preparation of the full-thickness tissue-engineered oral mucosa is also described. The clinical outcome of the tissue-engineered intraoral lining reconstruction and response after implant placement are reported. A peri-implant granulation tissue response was not observed when prelaminating the fibula, and little response was observed when intraoral grafting was performed. Tissue engineering represents an alternative method by which to obtain sufficient autologous tissue for reconstructing mucosal oral defects. The full-thickness engineered autologous oral mucosa offers definite advantages in terms of reconstruction planning, donor site morbidity, and quality of the intraoral soft tissue reconstruction, thereby restoring native tissue and avoiding peri-implant tissue complications. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Image-guided modified deep anterior lamellar keratoplasty (DALK) corneal transplant using intraoperative optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tao, Yuankai K.; LaBarbera, Michael; Ehlers, Justis P.; Srivastava, Sunil K.; Dupps, William J.

    2015-03-01

    Deep anterior lamellar keratoplasty (DALK) is an alternative to full-thickness corneal transplant and has advantages including the absence of allograft rejection; shortened duration of topical corticosteroid treatment and reduced associated risk of glaucoma, cataract, or infection; and enables use of grafts with poor endothelial quality. DALK begins by performing a trephination of approximately 80% stromal thickness, as measured by pachymetry. After removal of the anterior stoma, a needle is inserted into the residual stroma to inject air or viscoelastic to dissect Descemet's membrane. These procedures are inherently difficult and intraoperative rates of Descemet's membrane perforation between 4-39% have been reported. Optical coherence tomography (OCT) provides high-resolution images of tissue microstructures in the cornea, including Descemet's membrane, and allows quantitation of corneal layer thicknesses. Here, we use crosssectional intraoperative OCT (iOCT) measurements of corneal thickness during surgery and a novel micrometeradjustable biopsy punch to precision-cut the stroma down to Descemet's membrane. Our prototype cutting tool allows us to establish a dissection plane at the corneal endothelium interface, mitigates variability in cut-depths as a result of tremor, reduces procedure complexity, and reduces complication rates. iOCT-guided modified DALK procedures were performed on 47 cadaveric porcine eyes by non-experts and achieved a perforation rate of ~5% with a mean corneal dissection time <18 minutes. The procedure was also successful performed on a human donor eye without perforation. Our data shows the potential for iOCT-guided precision anterior segment surgery without variability as a result of tremor and improvements to standard clinical care.

  7. Dimensional soft tissue changes following soft tissue grafting in conjunction with implant placement or around present dental implants: a systematic review.

    PubMed

    Poskevicius, Lukas; Sidlauskas, Antanas; Galindo-Moreno, Pablo; Juodzbalys, Gintaras

    2017-01-01

    To systematically review changes in mucosal soft tissue thickness and keratinised mucosa width after soft tissue grafting around dental implants. An electronic literature search was conducted of the MEDLINE database published between 2009 and 2014. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in soft tissue thickness or keratinised mucosa width after soft tissue grafting at implant placement or around a present implant at 6-month follow-up or longer were included. The search resulted in fourteen articles meeting the inclusion criteria: Six of them reported connective tissue grafting around present dental implants, compared to eight at the time of implant placement. Better long-term soft tissue thickness outcomes were reported for soft tissue augmentation around dental implants (0.8-1.4 mm), compared with augmentation at implant placement (-0.25-1.43 mm). Both techniques were effective in increasing keratinised tissue width: at implant placement (2.5 mm) or around present dental implants (2.33-2.57 mm). The present systematic review discovered that connective tissue grafts enhanced keratinised mucosa width and soft tissue thickness for an observation period of up to 48 months. However, some shrinkage may occur, resulting in decreases in soft tissue, mostly for the first three months. Further investigations using accurate evaluation methods need to be done to evaluate the appropriate time for grafting. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Linking contemporary high resolution magnetic resonance imaging to the von Economo legacy: A study on the comparison of MRI cortical thickness and histological measurements of cortical structure.

    PubMed

    Scholtens, Lianne H; de Reus, Marcel A; van den Heuvel, Martijn P

    2015-08-01

    The cerebral cortex is a distinctive part of the mammalian nervous system, displaying a spatial variety in cyto-, chemico-, and myelinoarchitecture. As part of a rich history of histological findings, pioneering anatomists von Economo and Koskinas provided detailed mappings on the cellular structure of the human cortex, reporting on quantitative aspects of cytoarchitecture of cortical areas. Current day investigations into the structure of human cortex have embraced technological advances in Magnetic Resonance Imaging (MRI) to assess macroscale thickness and organization of the cortical mantle in vivo. However, direct comparisons between current day MRI estimates and the quantitative measurements of early anatomists have been limited. Here, we report on a simple, but nevertheless important cross-analysis between the histological reports of von Economo and Koskinas on variation in thickness of the cortical mantle and MRI derived measurements of cortical thickness. We translated the von Economo cortical atlas to a subdivision of the commonly used Desikan-Killiany atlas (as part of the FreeSurfer Software package and a commonly used parcellation atlas in studies examining MRI cortical thickness). Next, values of "width of the cortical mantle" as provided by the measurements of von Economo and Koskinas were correlated to cortical thickness measurements derived from high-resolution anatomical MRI T1 data of 200+ subjects of the Human Connectome Project (HCP). Cross-correlation revealed a significant association between group-averaged MRI measurements of cortical thickness and histological recordings (r = 0.54, P < 0.001). Further validating such a correlation, we manually segmented the von Economo parcellation atlas on the standardized Colin27 brain dataset and applied the obtained three-dimensional von Economo segmentation atlas to the T1 data of each of the HCP subjects. Highly consistent with our findings for the mapping to the Desikan-Killiany regions, cross-correlation between in vivo MRI cortical thickness and von Economo histology-derived values of cortical mantle width revealed a strong positive association (r = 0.62, P < 0.001). Linking today's state-of-the-art T1-weighted imaging to early histological examinations our findings indicate that MRI technology is a valid method for in vivo assessment of thickness of human cortex. © 2015 Wiley Periodicals, Inc.

  9. Mechanisms of weak thickness dependence of the critical current density in strong-pinning ex situ metal organic-deposition-route YBa2Cu3O7-x coated conductors

    NASA Astrophysics Data System (ADS)

    Kim, S. I.; Gurevich, A.; Song, X.; Li, X.; Zhang, W.; Kodenkandath, T.; Rupich, M. W.; Holesinger, T. G.; Larbalestier, D. C.

    2006-09-01

    We report on the thickness dependence of the superconducting characteristics including critical current Ic, critical current density Jc, transition temperature Tc, irreversibility field Hirr, bulk pinning force plot Fp(H), and normal state resistivity curve ρ(T) measured after successive ion milling of ~1 µm thick high-Ic YBa2Cu3O7-x films made by an ex situ metal-organic deposition process on Ni-W rolling-assisted biaxially textured substrates (RABiTSTM). In contrast to many recent data, mostly on in situ pulsed laser deposition (PLD) films, which show strong depression of Jc with increasing film thickness t, our films exhibit only a weak dependence of Jc on t. The two better textured samples had full cross-section average Jc,avg (77 K, 0 T) ~4 MA cm-2 near the buffer layer interface and ~3 MA cm-2 at full thickness, despite significant current blocking due to ~30% porosity in the film. Taking account of the thickness dependence of the porosity, we estimate that the local, vortex-pinning current density is essentially independent of thickness, while accounting for the additional current-blocking effects of grain boundaries leads to local, vortex-pinning Jc values well above 5 MA cm-2. Such high local Jc values are produced by strong three-dimensional vortex pinning which subdivides vortex lines into weakly coupled segments much shorter than the film thickness.

  10. Creation of a Bioengineered Skin Flap Scaffold with a Perfusable Vascular Pedicle.

    PubMed

    Jank, Bernhard J; Goverman, Jeremy; Guyette, Jacques P; Charest, Jon M; Randolph, Mark; Gaudette, Glenn R; Gershlak, Joshua R; Purschke, Martin; Javorsky, Emilia; Nazarian, Rosalynn M; Leonard, David A; Cetrulo, Curtis L; Austen, William G; Ott, Harald C

    2017-07-01

    Full-thickness skin loss is a challenging problem due to limited reconstructive options, demanding 75 million surgical procedures annually in the United States. Autologous skin grafting is the gold standard treatment, but results in donor-site morbidity and poor aesthetics. Numerous skin substitutes are available on the market to date, however, none truly functions as full-thickness skin due to lack of a vascular network. The creation of an autologous full-thickness skin analogue with a vascular pedicle would result in a paradigm shift in the management of wounds and in reconstruction of full-thickness skin defects. To create a clinically relevant foundation, we generated an acellular skin flap scaffold (SFS) with a perfusable vascular pedicle of clinically relevant size by perfusion decellularization of porcine fasciocutaneous flaps. We then analyzed the yielded SFS for mechanical properties, biocompatibility, and regenerative potential in vitro and in vivo. Furthermore, we assessed the immunological response using an in vivo model. Finally, we recellularized the vascular compartment of an SFS and reconnected it to a recipient's blood supply to test for perfusability. Perfusion decellularization removed all cellular components with preservation of native extracellular matrix composition and architecture. Biaxial testing revealed preserved mechanical properties. Immunologic response and biocompatibility assessed via implantation and compared with native xenogenic skin and commercially available dermal substitutes revealed rapid neovascularization and complete tissue integration. Composition of infiltrating immune cells showed no evidence of allorejection and resembled the inflammatory phase of wound healing. Implantation into full-thickness skin defects demonstrated good tissue integration and skin regeneration without cicatrization. We have developed a protocol for the generation of an SFS of clinically relevant size, containing a vascular pedicle, which can be utilized for perfusion decellularization and, ultimately, anastomosis to the recipient vascular system after precellularization. The observed favorable immunological response and good tissue integration indicate the substantial regenerative potential of this platform.

  11. Endoscopic full-thickness resection in the colorectum with a novel over-the-scope device: first experience.

    PubMed

    Schmidt, Arthur; Bauerfeind, Peter; Gubler, Christoph; Damm, Michael; Bauder, Markus; Caca, Karel

    2015-08-01

    Endoscopic full-thickness resection (EFTR) in the lower gastrointestinal tract may be a valuable therapeutic and diagnostic approach for a variety of indications. Although feasibility of EFTR has been demonstrated, there is a lack of safe and effective endoscopic devices for routine use. The aim of this study was to investigate the efficacy and safety of a novel over-the-scope device for colorectal EFTR. Between July 2012 and July 2014, 25 patients underwent EFTR at two tertiary referral centers. All resections were performed using the full-thickness resection device (FTRD; Ovesco Endoscopy, Tübingen, Germany). Data were collected retrospectively. Indications for EFTR were: recurrent or incompletely resected adenoma with nonlifting sign (n = 11), untreated adenoma and nonlifting sign (n = 2), adenoma involving the appendix (n = 5), flat adenoma in a patient with coagulopathy (n = 1), diagnostic re-resection after incomplete resection of a T1 carcinoma (n = 2), adenoma involving a diverticulum (n = 1), submucosal tumor (n = 2), and diagnostic resection in a patient with suspected Hirschsprung's disease (n = 1). In one patient, the lesion could not be reached because of a sigmoid stenosis. In the other patients, resection of the lesion was macroscopically complete and en bloc in 20/24 patients (83.3 %). The mean diameter of the resection specimen was 24 mm (range 12 - 40 mm). The R0 resection rate was 75.0 % (18/24), and full-thickness resection was histologically confirmed in 87.5 %. No perforations or major bleeding were observed during or after resection. Two patients developed postpolypectomy syndrome, which was managed with antibiotic therapy. Full-thickness resection in the lower gastrointestinal tract with the novel FTRD was feasible and effective. Prospective studies are needed to further evaluate the device and technique. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Development of a Full-Thickness Human Gingiva Equivalent Constructed from Immortalized Keratinocytes and Fibroblasts.

    PubMed

    Buskermolen, Jeroen K; Reijnders, Christianne M A; Spiekstra, Sander W; Steinberg, Thorsten; Kleverlaan, Cornelis J; Feilzer, Albert J; Bakker, Astrid D; Gibbs, Susan

    2016-08-01

    Organotypic models make it possible to investigate the unique properties of oral mucosa in vitro. For gingiva, the use of human primary keratinocytes (KC) and fibroblasts (Fib) is limited due to the availability and size of donor biopsies. The use of physiologically relevant immortalized cell lines would solve these problems. The aim of this study was to develop fully differentiated human gingiva equivalents (GE) constructed entirely from cell lines, to compare them with the primary cell counterpart (Prim), and to test relevance in an in vitro wound healing assay. Reconstructed gingiva epithelium on a gingiva fibroblast-populated collagen hydrogel was constructed from cell lines (keratinocytes: TERT or HPV immortalized; fibroblasts: TERT immortalized) and compared to GE-Prim and native gingiva. GE were characterized by immunohistochemical staining for proliferation (Ki67), epithelial differentiation (K10, K13), and basement membrane (collagen type IV and laminin 5). To test functionality of GE-TERT, full-thickness wounds were introduced. Reepithelialization, fibroblast repopulation of hydrogel, metabolic activity (MTT assay), and (pro-)inflammatory cytokine release (enzyme-linked immunosorbent assay) were assessed during wound closure over 7 days. Significant differences in basal KC cytokine secretion (IL-1α, IL-18, and CXCL8) were only observed between KC-Prim and KC-HPV. When Fib-Prim and Fib-TERT were stimulated with TNF-α, no differences were observed regarding cytokine secretion (IL-6, CXCL8, and CCL2). GE-TERT histology, keratin, and basement membrane protein expression very closely represented native gingiva and GE-Prim. In contrast, the epithelium of GE made with HPV-immortalized KC was disorganized, showing suprabasal proliferating cells, limited keratinocyte differentiation, and the absence of basement membrane proteins. When a wound was introduced into the more physiologically relevant GE-TERT model, an immediate inflammatory response (IL-6, CCL2, and CXCL8) was observed followed by complete reepithelialization. Seven days after wounding, tissue integrity, metabolic activity, and cytokine levels had returned to the prewounded state. In conclusion, immortalized human gingiva KC and fibroblasts can be used to make physiologically relevant GE, which resemble either the healthy gingiva or a neoplastic disease model. These organotypic models will provide valuable tools to investigate oral mucosa biology and can also be used as an animal alternative for drug targeting, vaccination studies, microbial biofilm studies, and testing new therapeutics.

  13. Development of a Full-Thickness Human Gingiva Equivalent Constructed from Immortalized Keratinocytes and Fibroblasts

    PubMed Central

    Buskermolen, Jeroen K.; Reijnders, Christianne M.A.; Spiekstra, Sander W.; Steinberg, Thorsten; Kleverlaan, Cornelis J.; Feilzer, Albert J.; Bakker, Astrid D.

    2016-01-01

    Organotypic models make it possible to investigate the unique properties of oral mucosa in vitro. For gingiva, the use of human primary keratinocytes (KC) and fibroblasts (Fib) is limited due to the availability and size of donor biopsies. The use of physiologically relevant immortalized cell lines would solve these problems. The aim of this study was to develop fully differentiated human gingiva equivalents (GE) constructed entirely from cell lines, to compare them with the primary cell counterpart (Prim), and to test relevance in an in vitro wound healing assay. Reconstructed gingiva epithelium on a gingiva fibroblast-populated collagen hydrogel was constructed from cell lines (keratinocytes: TERT or HPV immortalized; fibroblasts: TERT immortalized) and compared to GE-Prim and native gingiva. GE were characterized by immunohistochemical staining for proliferation (Ki67), epithelial differentiation (K10, K13), and basement membrane (collagen type IV and laminin 5). To test functionality of GE-TERT, full-thickness wounds were introduced. Reepithelialization, fibroblast repopulation of hydrogel, metabolic activity (MTT assay), and (pro-)inflammatory cytokine release (enzyme-linked immunosorbent assay) were assessed during wound closure over 7 days. Significant differences in basal KC cytokine secretion (IL-1α, IL-18, and CXCL8) were only observed between KC-Prim and KC-HPV. When Fib-Prim and Fib-TERT were stimulated with TNF-α, no differences were observed regarding cytokine secretion (IL-6, CXCL8, and CCL2). GE-TERT histology, keratin, and basement membrane protein expression very closely represented native gingiva and GE-Prim. In contrast, the epithelium of GE made with HPV-immortalized KC was disorganized, showing suprabasal proliferating cells, limited keratinocyte differentiation, and the absence of basement membrane proteins. When a wound was introduced into the more physiologically relevant GE-TERT model, an immediate inflammatory response (IL-6, CCL2, and CXCL8) was observed followed by complete reepithelialization. Seven days after wounding, tissue integrity, metabolic activity, and cytokine levels had returned to the prewounded state. In conclusion, immortalized human gingiva KC and fibroblasts can be used to make physiologically relevant GE, which resemble either the healthy gingiva or a neoplastic disease model. These organotypic models will provide valuable tools to investigate oral mucosa biology and can also be used as an animal alternative for drug targeting, vaccination studies, microbial biofilm studies, and testing new therapeutics. PMID:27406216

  14. The use of type 1 collagen scaffold containing stromal cell-derived factor-1 to create a matrix environment conducive to partial-thickness cartilage defects repair.

    PubMed

    Zhang, Wei; Chen, Jialin; Tao, Jiadong; Jiang, Yangzi; Hu, Changchang; Huang, Lu; Ji, Junfeng; Ouyang, Hong Wei

    2013-01-01

    Despite the presence of cartilage-derived mesenchymal stem cells (C-MSCs) and synovial membrane-derived mesenchymal stem cells (SM-MSCs) populations, partial-thickness cartilage defects, in contrast to the full-thickness defects, are devoid of spontaneous repair capacity. This study aims to create an in situ matrix environment conducive to C-MSCs and SM-MSCs to promote cartilage self-repair. Spontaneous repair with MSCs migration into the defect area was observed in full-thickness defects, but not in partial-thickness defects in rabbit model. Ex vivo and in vitro studies showed that subchondral bone or type 1 collagen (col1) scaffold was more permissive for MSCs adhesion than cartilage or type 2 collagen (col2) scaffold and induced robust stromal cell-derived factors-1 (SDF-1) dependent migration of MSCs. Furthermore, creating a matrix environment with col1 scaffold containing SDF-1 enhanced in situ self-repair of partial-thickness defects in rabbit 6 weeks post-injury. Hence, the inferior self-repair capacity in partial-thickness defects is partially owing to the non-permissive matrix environment. Creating an in situ matrix environment conducive to C-MSCs and SM-MSCs migration and adhesion with col1 scaffold containing SDF-1 can be exploited to improve self-repair capacity of cartilage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Wound Tissue Can Utilize a Polymeric Template to Synthesize a Functional Extension of Skin

    NASA Astrophysics Data System (ADS)

    Yannas, I. V.; Burke, J. F.; Orgill, D. P.; Skrabut, E. M.

    1982-01-01

    Prompt and long-term closure of full-thickness skin wounds in guinea pigs and humans is achieved by applying a bilayer polymeric membrane. The membrane comprises a top layer of a silicone elastomer and a bottom layer of a porous cross-linked network of collagen and glycosaminoglycan. The bottom layer can be seeded with a small number of autologous basal cells before grafting. No immunosuppression is used and infection, exudation, and rejection are absent. Host tissue utilizes the sterile membrane as a culture medium to synthesize neoepidermal and neodermal tissue. A functional extension of skin over the entire wound area is formed in about 4 weeks.

  16. A new continuous suture technique in ear reconstruction with full-thickness skin grafts.

    PubMed

    Bramhall, Russell James; Gorman, Mark; Khan, Muhammad Adil Abbas; Riaz, Muhammad

    2012-07-01

    Ear reconstruction with full-thickness skin grafts can be a challenging task for plastic surgeons. It is often necessary to remove the underlying cartilage with the skin lesion and the resultant defect may be deeply concave. We present a short clinical report to describe an improved technique that we find useful in reducing the diameter and depth of anterior pinna contour defects, in improving graft take, and in reducing the size of the donor-site scar.

  17. A Rat Model of Full Thickness Thermal Injury Characterized by Thermal Hyperalgesia, Mechanical Allodynia, Pronociceptive Peptide Release and Tramadol Analgesia

    DTIC Science & Technology

    2014-01-01

    tramadol reduces acute, postoperative, neuropathic and cancer pain [9,10,12 14] and may have a lower propensity to induce addiction [15] with little to...opioid systems simultaneously, we next examined whether tramadol could attenuate burn evoked pain behaviors in our rat model of full thickness thermal...injury. Tramadol attenuated thermal hyperalgesia when administered one week following thermal injury, a time point when pain behaviors peak in this

  18. Endoscopic full-thickness resection: Current status

    PubMed Central

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-01-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices. PMID:26309354

  19. Endoscopic full-thickness resection: Current status.

    PubMed

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-08-21

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.

  20. Porcine sclera as a model of human sclera for in vitro transport experiments: histology, SEM, and comparative permeability

    PubMed Central

    Ferrari, G.; Quarta, M.; Macaluso, C.; Govoni, P.; Dallatana, D.; Santi, P.

    2009-01-01

    Purpose To evaluate porcine sclera as a model of human sclera for in vitro studies of transscleral drug delivery of both low and high molecular weight compounds. Methods Human and porcine scleras were characterized for thickness and water content. The tissue surface was examined by scanning electron microscopy (SEM), and the histology was studied with hematoxylin-eosin staining. Comparative permeation experiments were performed using three model molecules, acetaminophen as the model compound for small molecules; a linear dextran with a molecular weight of 120 kDa as the model compound for high molecular weight drugs; and insulin, which was chosen as the model protein. Permeation parameters such as flux, lag time, and permeability coefficient were determined and compared. Results Human and porcine scleras have a similar histology and collagen bundle organization. The water content is approx 70% for both tissues while a statistically significant difference was found for the thickness, porcine sclera being approximately twofold thicker than human sclera. Differences in thickness produced differences in the permeability coefficient. In fact, human sclera was found to be two to threefold more permeable toward the three molecules studied than porcine sclera. Conclusions The results obtained in the present paper prove that porcine sclera can be considered a good model for human sclera for in vitro permeation experiments of both low and high molecular weight compounds. In fact, if the different tissue thickness is taken into account, comparable permeability was demonstrated. This suggests a possible use of this model in the evaluation of the transscleral permeation of new biotech compounds, which currently represent the most innovative and efficient therapeutic options for the treatment of ocular diseases. PMID:19190734

  1. Porcine sclera as a model of human sclera for in vitro transport experiments: histology, SEM, and comparative permeability.

    PubMed

    Nicoli, S; Ferrari, G; Quarta, M; Macaluso, C; Govoni, P; Dallatana, D; Santi, P

    2009-01-01

    To evaluate porcine sclera as a model of human sclera for in vitro studies of transscleral drug delivery of both low and high molecular weight compounds. Human and porcine scleras were characterized for thickness and water content. The tissue surface was examined by scanning electron microscopy (SEM), and the histology was studied with hematoxylin-eosin staining. Comparative permeation experiments were performed using three model molecules, acetaminophen as the model compound for small molecules; a linear dextran with a molecular weight of 120 kDa as the model compound for high molecular weight drugs; and insulin, which was chosen as the model protein. Permeation parameters such as flux, lag time, and permeability coefficient were determined and compared. Human and porcine scleras have a similar histology and collagen bundle organization. The water content is approx 70% for both tissues while a statistically significant difference was found for the thickness, porcine sclera being approximately twofold thicker than human sclera. Differences in thickness produced differences in the permeability coefficient. In fact, human sclera was found to be two to threefold more permeable toward the three molecules studied than porcine sclera. The results obtained in the present paper prove that porcine sclera can be considered a good model for human sclera for in vitro permeation experiments of both low and high molecular weight compounds. In fact, if the different tissue thickness is taken into account, comparable permeability was demonstrated. This suggests a possible use of this model in the evaluation of the transscleral permeation of new biotech compounds, which currently represent the most innovative and efficient therapeutic options for the treatment of ocular diseases.

  2. Dermal Coverage of Traumatic War Wounds

    DTIC Science & Technology

    2017-01-01

    Device for re-epithelialization of full thickness wounds treated with INTEGRA MBWM. The ReCell Device is a stand-alone, battery operated cell...standalone, battery operated cell separation device that enables preparation of a cell suspension from a small, thin, split-thickness skin biopsy

  3. Corneal endothelial autocrine trophic factor VIP in a mechanism-based strategy to enhance human donor cornea preservation for transplantation.

    PubMed

    Koh, Shay-Whey Margaret

    2012-02-01

    Vasoactive intestinal peptide (VIP) and ciliary neurotrophic factor (CNTF) are identified as autocrines of human corneal endothelial (CE) cells working in concert to maintain the differentiated state and promote the survival of the corneal endothelium. From VIP gene knockdown study, endogenous VIP is shown to maintain the level of the differentiation marker, the adhesion molecule N-cadherin, CE cell size, shape, and retention, in situ in the human donor corneoscleral explants. Exogenous VIP protects the corneal endothelium against the killing effect of oxidative stress, in part by upholding ATP levels in CE cells dying of oxidative stress-induced injury, allowing them to die of an apoptotic death instead of an acute necrotic one. The switch from the acute necrosis to the programmed cell death (apoptosis) may have allowed the injured CE cell to be rescued by the VIP-upregulated pathways, including those of Bcl-2 and N-cadherin, and resulted in long-term CE cell survival. The endogenous VIP in CE cells is upregulated by CNTF, which is released by CE cells surviving the oxidative stress. The CNTF receptor (CNTFRα) is expressed in CE cells in human donor corneoscleral explant and gradually becomes lost during corneal storage. VIP treatment (10(-8) M, 37 °C, 30 min) prior to storage of freshly dissected human donor corneoscleral explants increases their CE cell CNTFRα level and responsiveness to CNTF in upregulating the gap junctional protein connexin-43 expression. VIP treatment of both fresh and preserved corneoscleral explants reduces CE damage in the corneoscleral explants and in the corneal buttons trephined from them. CE cell loss is a critical risk factor in corneal graft failure at any time in the life of the graft, which can be as late as 5-10 years after an initially successful transplant. A new procedure, Descemet's stripping automated endothelial keratoplasty (DSAEK), which is superior to the traditional full thickness transplantation in many aspects, nevertheless subjects the corneal endothelium to extensive mechanical forces, resulting in even more pronounced CE cell loss than the traditional technique. Whereas it is known that cells transduce mechanical stress through N-cadherin, stimulation of the N-cadherin pathway increases the anti-apoptotic protein Bcl-2 expression. Since N-cadherin and Bcl-2 in the corneal endothelium are both upregulated by VIP, we aim to strengthen the CE sheet by VIP treatments of the corneoscleral explants for full thickness traditional corneal transplantation and pre-cut corneas for DSAEK. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Excision of Oral Submucous Fibrosis and Reconstruction with Full Thickness Skin Graft: A Case Study and Review of the Literature

    PubMed Central

    Alshadwi, Ahmad; Bhatia, Ishwar

    2012-01-01

    Oral submucous fibrosis is a chronic debilitating disease characterized by gradually increasing fibrosis of the oral cavity and pharynx, mainly the buccal mucosa, resulting in trismus. The highest incidence of oral submucous fibrosis is seen in South India due to various deleterious habits. In spite of the numerous medical modalities employed in the management of oral submucous fibrosis, occasionally surgical intervention becomes inevitable. Various surgical approaches have been used to reconstruct the surgical defects following excision of fibrous bands. Full thickness skin grafts have been described in the literature with variable outcomes. In the present study a 38-year-old male presented with severe oral submucous fibrosis of the buccal mucosa, which was successfully treated and reconstructed using full thickness skin graft with stable functional result after one year of treatment. An integrated review of the literature regarding etiology, histopathology, diagnostic, and treatment modalities of the disease follows. PMID:23304568

  5. Cutting edge of endoscopic full-thickness resection for gastric tumor

    PubMed Central

    Maehata, Tadateru; Goto, Osamu; Takeuchi, Hiroya; Kitagawa, Yuko; Yahagi, Naohisa

    2015-01-01

    Recently, several studies have reported local full-thickness resection techniques using flexible endoscopy for gastric tumors, such as gastrointestinal stromal tumors, gastric carcinoid tumors, and early gastric cancer (EGC). These techniques have the advantage of allowing precise resection lines to be determined using intraluminal endoscopy. Thus, it is possible to minimize the resection area and subsequent deformity. Some of these methods include: (1) classical laparoscopic and endoscopic cooperative surgery (LECS); (2) inverted LECS; (3) combination of laparoscopic and endoscopic approaches to neoplasia with non-exposure technique; and (4) non-exposed endoscopic wall-inversion surgery. Furthermore, a recent prospective multicenter trial of the sentinel node navigation surgery (SNNS) for EGC has shown acceptable results in terms of sentinel node detection rate and the accuracy of nodal metastasis. Endoscopic full-thickness resection with SNNS is expected to become a treatment option that bridges the gap between endoscopic submucosal dissection and standard surgery for EGC. In the future, the indications for these procedures for gastric tumors could be expanded. PMID:26566427

  6. Development of an integrative algorithm for the treatment of various stages of full-thickness burns of the first commissure of the hand.

    PubMed

    Yuste, Valentin; Delgado, Julio; Agullo, Alberto; Sampietro, Jose Mauel

    2017-06-01

    Burns of the first commissure of the hand can evolve into an adduction contracture of the thumb. We decided to conduct a review of the existing literature on the treatment of full-thickness burns of the first commissure in order to develop a treatment algorithm that integrates the various currently available procedures. A search of the existing literature was conducted, focusing on the treatment of a burn of the first commissure in its chronic and acute phases. A total of 29 relevant articles were selected; 24 focused exclusively on the chronic contracture stage, while 3 focused exclusively on the acute burn stage, and 2 articles studied both stages. A therapeutic algorithm for full-thickness burns of the first commissure of the hand was developed. With this algorithm we sought to relate each degree and stage of the burn with a treatment. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  7. Effects of Birth Weight on Anterior Segment Measurements in Full-Term Children Without Low Birth Weight by Dual-Scheimpflug Analyzer.

    PubMed

    Yeter, Volkan; Aritürk, Nurşen; Bİrİncİ, Hakki; Süllü, Yüksel; Güngör, İncİ

    2015-10-01

    To evaluate the effects of birth weight on ocular anterior segment parameters in full-term children without low birth weight using the Galilei Dual-Scheimpflug Analyzer. Retrospective cohort study. The right eyes from 110 healthy children, 3-6 years of age, were scanned with the Galilei Dual-Scheimpflug Analyzer. A total of 78 eyes were measured in full-term children with birth weight of >2500 g. Central, paracentral, pericentral, and the thinnest corneal thicknesses; anterior and posterior keratometry (average, steep, flat); axial curvatures; asphericity of cornea; anterior chamber depth and volume; and iridocorneal angle values were measured. Axial length, lens thickness, and vitreous length were obtained by ultrasound biometry. The mean age of children was 55.86 ± 12.52 (mean ± SD) months. Mean birth weight and gestational age were 3426.3 ± 545 g and 39.4 ± 1.2 weeks, respectively. Although lens thickness, vitreous length, axial length, and anterior chamber volume were moderately correlated with birth weight (P < .05), there was no relationship between birth weight and anterior chamber depth. With the exception of pericentral corneal thickness, all regions of corneal thicknesses were correlated with birth weight (P < .05). Birth weight was negatively correlated with anterior curvature (P < .05) and had no relationship to posterior curvature. While central and paracentral axial curvatures correlated with birth weight (P < .05), pericentral axial curvature did not. Preschoolers who were born heavier had thicker cornea and lens, longer axial length, and flatter corneal curve. The thicknesses and axial curves of central cornea within 7 mm may be particularly associated with birth weight. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Transcranial Near-Infrared Laser Transmission (NILT) Profiles (800 nm): Systematic Comparison in Four Common Research Species

    PubMed Central

    Lapchak, Paul A.; Boitano, Paul D.; Butte, Pramod V.; Fisher, David J.; Hölscher, Thilo; Ley, Eric J.; Nuño, Miriam; Voie, Arne H.; Rajput, Padmesh S.

    2015-01-01

    Background and Purpose Transcranial near-infrared laser therapy (TLT) is a promising and novel method to promote neuroprotection and clinical improvement in both acute and chronic neurodegenerative diseases such as acute ischemic stroke (AIS), traumatic brain injury (TBI), and Alzheimer’s disease (AD) patients based upon efficacy in translational animal models. However, there is limited information in the peer-reviewed literature pertaining to transcranial near-infrared laser transmission (NILT) profiles in various species. Thus, in the present study we systematically evaluated NILT characteristics through the skull of 4 different species: mouse, rat, rabbit and human. Results Using dehydrated skulls from 3 animal species, using a wavelength of 800nm and a surface power density of 700 mW/cm2, NILT decreased from 40.10% (mouse) to 21.24% (rat) to 11.36% (rabbit) as skull thickness measured at bregma increased from 0.44 mm in mouse to 0.83 mm in rat and then 2.11 mm in rabbit. NILT also significantly increased (p<0.05) when animal skulls were hydrated (i.e. compared to dehydrated); but there was no measurable change in thickness due to hydration. In human calvaria, where mean thickness ranged from 7.19 mm at bregma to 5.91 mm in the parietal skull, only 4.18% and 4.24% of applied near-infrared light was transmitted through the skull. There was a slight (9.2-13.4%), but insignificant effect of hydration state on NILT transmission of human skulls, but there was a significant positive correlation between NILT and thickness at bregma and parietal skull, in both hydrated and dehydrated states. Conclusion This is the first systematic study to demonstrate differential NILT through the skulls of 4 different species; with an inverse relationship between NILT and skull thickness. With animal skulls, transmission profiles are dependent upon the hydration state of the skull, with significantly greater penetration through hydrated skulls compared to dehydrated skulls. Using human skulls, we demonstrate a significant correlation between thickness and penetration, but there was no correlation with skull density. The results suggest that TLT should be optimized in animals using novel approaches incorporating human skull characteristics, because of significant variance of NILT profiles directly related to skull thickness. PMID:26039354

  9. [Establishment of a keloid model by transplanting human keloid onto the backs of nude mice].

    PubMed

    Philandrianos, C; Gonnelli, D; Andrac-Meyer, L; Bruno, M; Magalon, G; Mordon, S

    2014-08-01

    Keloid scar is a proliferative healing dysfunction formed by an excessive build-up of collagen fibers on the dermis. It is responsible of aesthetic and functional disabilities. There is no ideal treatment and recurrence occurs very often. Keloid scars occur only to human, that's why animal model needs to be made to study this pathology and new treatments. Few models have been described using human keloid scars implanted into subcutaneous tissue of nude mice or rat. To allow study of topical and laser treatment we have developed a new animal model using human keloid scar fragment with epidermal and dermal tissue implanted into back of nude mice like a full thickness skin graft. Keloid fragments from five donors have been grafted onto 40 nudes mice. Macroscopic and microscopic studies have been made at day 28, 56, 84 and 112. We observed integration of the fragments in all cases. Hyalinized collagen bundles were observed in all implant biopsies confirming the stability of the keloid architecture within 112 days. This model is easily reproducible and allows the study of topical treatment and laser due to the accessibility of the keloid. Copyright © 2012. Published by Elsevier Masson SAS.

  10. In vivo sweat film layer thickness measured with Fourier-domain optical coherence tomography (FD-OCT)

    NASA Astrophysics Data System (ADS)

    Jonathan, Enock

    2008-06-01

    While human sweat secretion is accepted as a mechanism by which the body cools off, excessive sweating (hyperhidrosis) is now appreciated as a medical condition and the primary site for diagnosis is the palm of the hand. We propose sweat film layer thickness as a potential clinical diagnostic parameter when screening for excessive sweating. In this preliminary study we demonstrate the usefulness of Fourier-domain optical coherence tomography (FD-OCT) for measurement of sweat film thickness in vivo with micron-scale resolution on the hand of a human volunteer. FD-OCT has a superior image acquisition time and identification of active sweat glands, ducts and pores is also possible.

  11. Improved Survival of Full-Thickness Skin Graft With Low-Molecular Weight Heparin-Protamine Micro/Nanoparticles Including Platelet-Rich Plasma.

    PubMed

    Takabayashi, Yuki; Ishihara, Masayuki; Kuwabara, Masahiro; Takikawa, Makoto; Nakamura, Shingo; Hattori, Hidemi; Kiyosawa, Tomoharu

    2017-05-01

    Activated platelet-rich plasma secrets many growth factors (GFs), and low-molecular weight heparin-protamine micro/nanoparticles (LMWH-P M/NPs) significantly interact with, enhance, and stabilize the secreted GFs. The purpose of this study was to evaluate the effects of LMWH-P M/NPs and GFs (from platelet-rich plasma) on full-thickness skin graft (FTSG). A total of 96 inbred male rats were anesthetized and 4-cm full-thickness skin wound were created on dorsal skin of rats. LMWH-P M/NPs and GFs, LMWH-P M/NPs, GFs and saline (control) were then injected evenly into cutaneous muscles at the wound. The next day, the rats underwent FTSG. On the indicated days after FTSG, blood flow of FTSG site (wound bed and FTSG) was examined by 2-dimensional laser Doppler blood flowmeter. On 10 days, pictures of FTSG site were taken and FTSG survival rate was evaluated. Histologic analyses of skin samples were performed on 4, 7, and 10 days. Treatment of full-thickness skin wound with LMWH-P M/NPs and GFs effectively promoted survival rate of FTSG and blood flow of FTSG site compared with those treated with GFs, LMWH-P M/NPs, and control. LMWH-P M/NPs and GFs also promoted new vessel formation at FTSG site. The prior injection of LMWH-P M/NPs and GFs into wound bed increases FTSG survival rate, and promotes blood flow and angiogenesis at FTSG site.

  12. Comparative trial of octyl-cyanoacrylate and silver sulfadiazine for the treatment of full-thickness skin wounds.

    PubMed

    Singer, A J; Berrutti, L; McClain, S A

    1999-01-01

    A prospective, randomized, blinded, controlled experimental trial was performed in pigs to compare the rates of reepithelialization of 126 full-thickness cutaneous 4-mm punches treated with an octyl-cyanoacrylate spray, silver sulfadiazine, or a dry gauze (controls). Full thickness biopsies were taken 7, 14, or 30 days later for histopathological evaluation of hematoxylin and eosin stained tissue sections by a dermatopathologist. The primary outcome measure was the proportion of wounds completely re-epithelialized at days 7 and 14. Secondary outcomes were the rates of infection, foreign body reactions, and the depth of any resulting cutaneous dells measured with a micrometer. Between-group comparisons were performed with ANOVA or Chi-square tests. Octyl-cyanoacrylate treated wounds re-epithelialized more slowly, as fewer wounds treated with octyl-cyanoacrylate were re-epithelialized at day 7 in comparison with silver sulfadiazine or control wounds (50% vs. 90% vs. 100%, p < 0.001). There were no infections or foreign body type reactions. Amounts of granulation tissue were similar among groups. Octyl-cyanoacrylate wounds were more depressed than silver sulfadiazine wounds at days 7 and 14 yet had similar histopathological characteristics at day 30. We conclude that treatment of small, full thickness cutaneous wounds with octyl-cyanoacrylate results in delayed re-epithelialization and dermal repair in comparison with silver sulfadiazine, yet it does not result in any foreign body-type reaction. However, by 30 days, histopathological wound characteristics were similar in all groups.

  13. Healing effect of sea buckthorn, olive oil, and their mixture on full-thickness burn wounds.

    PubMed

    Edraki, Mitra; Akbarzadeh, Armin; Hosseinzadeh, Massood; Tanideh, Nader; Salehi, Alireza; Koohi-Hosseinabadi, Omid

    2014-07-01

    The purpose of this study is to evaluate the healing effect of silver sulfadiazine (SSD), sea buckthorn, olive oil, and 5% sea buckthorn and olive oil mixture on full-thickness burn wounds with respect to both gross and histopathologic features. Full-thickness burns were induced on 60 rats; the rats were then were divided into 5 groups and treated with sea buckthorn, olive oil, a 5% sea buckthorn/olive oil mixture, SSD, and normal saline (control). They were observed for 28 days, and the wounds' healing process was evaluated. Wound contraction occurred faster in sea buckthorn, olive oil, and the sea buckthorn/olive oil mixture groups compared with the SSD and control groups. The volume of the exudates was controlled more effectively in wounds treated with the sea buckthorn/olive oil mixture. Purulent exudates were observed in the control group, but the others did not show infection. The group treated with sea buckthorn/olive oil mixture revealed more developed re-epithelialization with continuous basement membrane with a mature granulation tissue, whereas the SSD-treated group showed ulceration, necrosis, and immature granulation. The results show that sea buckthorn and olive oil individually are proper dressing for burn wounds and that they also show a synergetic effect when they are used together. A sea buckthorn and olive oil mixture could be considered as an alternative dressing for full-thickness burns because of improved wound healing characteristics and antibacterial property.

  14. The changes in resting anal pressure after performing full-thickness rectal advancement flaps.

    PubMed

    Balciscueta, Zutoia; Uribe, Natalia; Mínguez, Miguel; García-Granero, Eduardo

    2017-09-01

    Advancement flap is an accepted approach for treating complex fistula-in-ano.The purpose was to evaluate the changes in resting pressure along the anal canal after performing a full-thickness flap. Manometric review of patients who have undergone a full-thickness rectal advancement flap procedure for complex anal fistulas of cryptoglandular origin. Recurrence and continence were evaluated. Resting Anal Pressure was assessed along the anal canal by two measures: maximum resting pressure(MRP) and inferior resting pressure(IRP) at 0.5 cm from the anal verge. 119 patients were evaluated. Overall recurrence rate was5.9%. Anal continence was maintained intact in 76.5%. Manometric study showed a significant decrease in postoperative MRP(90.6 ± 31.9 to 45.2 ± 20 mmHg; p < 0.001), while IRP values did not differ significantly(28.2 ± 18.3 to 23.2 ± 13.5 mmHg; p = 0.1). Performing a full-thickness rectal flap causes a decrease of the MRP in the middle third of the anal canal, due to the inclusion of the internal sphincter in flap. It seems crucial to preserve the distal internal sphincter intact as it helps both to maintain the resting pressure in the lower third and avoid deformities of the anal margin. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Repair of full-thickness tendon injury using connective tissue progenitors efficiently derived from human embryonic stem cells and fetal tissues.

    PubMed

    Cohen, Shahar; Leshansky, Lucy; Zussman, Eyal; Burman, Michael; Srouji, Samer; Livne, Erella; Abramov, Natalie; Itskovitz-Eldor, Joseph

    2010-10-01

    The use of stem cells for tissue engineering (TE) encourages scientists to design new platforms in the field of regenerative and reconstructive medicine. Human embryonic stem cells (hESC) have been proposed to be an important cell source for cell-based TE applications as well as an exciting tool for investigating the fundamentals of human development. Here, we describe the efficient derivation of connective tissue progenitors (CTPs) from hESC lines and fetal tissues. The CTPs were significantly expanded and induced to generate tendon tissues in vitro, with ultrastructural characteristics and biomechanical properties typical of mature tendons. We describe a simple method for engineering tendon grafts that can successfully repair injured Achilles tendons and restore the ankle joint extension movement in mice. We also show the CTP's ability to differentiate into bone, cartilage, and fat both in vitro and in vivo. This study offers evidence for the possibility of using stem cell-derived engineered grafts to replace missing tissues, and sets a basic platform for future cell-based TE applications in the fields of orthopedics and reconstructive surgery.

  16. Calculation of catalyst crust thickness from full elemental laser-induced breakdown spectroscopy images

    NASA Astrophysics Data System (ADS)

    Sorbier, L.; Trichard, F.; Moncayo, S.; Lienemann, C. P.; Motto-Ros, V.

    2018-01-01

    We propose a methodology to compute the crust thickness of an element in an egg-shell catalyst from a two-dimensional elemental map. The methodology handles two important catalyst shapes: infinite extrudates of arbitrary section and spheres. The methodology is validated with synthetic analytical profiles on simple shapes (cylinder and sphere). Its relative accuracy is shown close to few percent with a decrease inversely proportional to the square root of the number of sampled pixels. The crust thickness obtained by this method from quantitative Pd maps acquired by laser-induced breakdown spectroscopy are comparable with values obtained from electron-probe microanalysis profiles. Some discrepancies are found and are explained by the heterogeneity of the crust thickness within a grain. As a full map is more representative than a single profile, fast mapping and the methodology exposed in this paper are expected to become valuable tools for the development of new generations of egg-shell deposited catalysts.

  17. Estimation of Sea Ice Thickness Distributions through the Combination of Snow Depth and Satellite Laser Altimetry Data

    NASA Technical Reports Server (NTRS)

    Kurtz, Nathan T.; Markus, Thorsten; Cavalieri, Donald J.; Sparling, Lynn C.; Krabill, William B.; Gasiewski, Albin J.; Sonntag, John G.

    2009-01-01

    Combinations of sea ice freeboard and snow depth measurements from satellite data have the potential to provide a means to derive global sea ice thickness values. However, large differences in spatial coverage and resolution between the measurements lead to uncertainties when combining the data. High resolution airborne laser altimeter retrievals of snow-ice freeboard and passive microwave retrievals of snow depth taken in March 2006 provide insight into the spatial variability of these quantities as well as optimal methods for combining high resolution satellite altimeter measurements with low resolution snow depth data. The aircraft measurements show a relationship between freeboard and snow depth for thin ice allowing the development of a method for estimating sea ice thickness from satellite laser altimetry data at their full spatial resolution. This method is used to estimate snow and ice thicknesses for the Arctic basin through the combination of freeboard data from ICESat, snow depth data over first-year ice from AMSR-E, and snow depth over multiyear ice from climatological data. Due to the non-linear dependence of heat flux on ice thickness, the impact on heat flux calculations when maintaining the full resolution of the ICESat data for ice thickness estimates is explored for typical winter conditions. Calculations of the basin-wide mean heat flux and ice growth rate using snow and ice thickness values at the 70 m spatial resolution of ICESat are found to be approximately one-third higher than those calculated from 25 km mean ice thickness values.

  18. Effects of a human VEGF antibody (Bevacizumab) on deprivation myopia and choroidal thickness in the chicken.

    PubMed

    Mathis, Ute; Ziemssen, Focke; Schaeffel, Frank

    2014-10-01

    Vascular endothelial growth factor (VEGF) is a dimeric glycoprotein which is responsible for neovascularization and fenestrations of the choriocapillaris. In neovascular maculopathies secondary to age-related degeneration (nAMD) or pathologic myopia (PM-CNV), its inhibition by humanized antibodies is currently the most successful therapy. The choroid has an important role in maintaining retinal health and its thickness declines with age and with myopia. Since choroidal thickness depends on its perfusion rate, one would expect that anti-VEGF agents can also change choroidal thickness. We have tested the hypothesis in the chicken model, using a humanized antibody, Bevacizumab, and also studied the distribution of VEGF-A in the chicken fundal layers by immunohistochemical techniques. Even though it was raised against human VEGF, Bevacizumab had several long lasting effects in the chicken eye (1) after a single unilateral intravitreal injection of 0.5 mg, it partially suppressed the development of deprivation myopia, similarly in both eyes, (2) it completely suppressed choroidal thickening that normally occurs when eyes recover from induced myopia over a time period of about 10 days, (3) it had little effect on the choroidal thickness in eyes that had normal visual experience, (4) VEGF-A was absent in sclera, but highly expressed in the walls of choroidal blood vessels and presumed nerve fiber bundles, as well as in retinal photoreceptors and cells of the inner and outer nuclear layer. One day after the injection of Bevacizumab, the immunoreactivity against VEGF-A had largely disappeared. In conclusion, Bevacizumab is similary effective in human and chicken tissue, has similar time constants (few days), has almost symmetrical effects on myopia in both eyes even after monocular application, and fully suppresses choroidal thickening that normally occurs during recovery from deprivation myopia. The mechanisms by which Bevacizumab acts on the choroidal thickness are perhaps most interesting, both to better understand the role of the choroid in myopia development but also to clarify its potential side effects during nAMD and PM-CNV treatment in the clinics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Fetal Bovine Collagen Matrix in the Treatment of a Full Thickness Burn Wound: A Case Report With Long-Term Follow-Up.

    PubMed

    Strong, Amy L; Bennett, Danielle K; Spreen, Elizabeth B; Adhvaryu, Dhaval V; Littleton, Jeffrey C; Mencer, Ernest J

    2016-01-01

    The treatment of full thickness skin wounds commonly associated with large burns continues to represent a challenging clinical entity. The current treatment for large TBSA burns is split thickness autologous skin grafting; however, this treatment often results in poor textural durability, hypertrophic scarring, and fibrotic contractures. In this case report, we describe our experience and long-term follow-up results after the application of fetal bovine collagen (FBC) matrix (PriMatrix, TEI Biosciences, Boston, MA) to burn wounds clinically assessed as full thickness that healed without the need for subsequent skin grafting. The patient presented with 25% TBSA burns and was debrided and covered with FBC on postburn day 7. By postoperative day 12, the patient had large areas of reepithelialization distributed throughout the wound bed. By postoperative day 26, the patient had significantly more areas of wound closure and was discharged. Reepithelialization and repigmentation continued, and long-term follow-up after 26 months demonstrated complete reepithelialization and nearly complete repigmentation, without the appearance of contractures or hypertrophic scarring. This case report highlights the use of FBC as a scaffold capable of dermal regeneration and spontaneous reepithelialization with an excellent long-term functional and cosmetic outcome.

  20. Fetal Bovine Collagen Matrix in the Treatment of a Full Thickness Burn Wound: A Case Report With Long-Term Follow-Up

    PubMed Central

    Strong, Amy L.; Bennett, Danielle K.; Spreen, Elizabeth B.; Adhvaryu, Dhaval V.; Littleton, Jeffrey C.

    2016-01-01

    The treatment of full thickness skin wounds commonly associated with large burns continues to represent a challenging clinical entity. The current treatment for large TBSA burns is split thickness autologous skin grafting; however, this treatment often results in poor textural durability, hypertrophic scarring, and fibrotic contractures. In this case report, we describe our experience and long-term follow-up results after the application of fetal bovine collagen (FBC) matrix (PriMatrix, TEI Biosciences, Boston, MA) to burn wounds clinically assessed as full thickness that healed without the need for subsequent skin grafting. The patient presented with 25% TBSA burns and was debrided and covered with FBC on postburn day 7. By postoperative day 12, the patient had large areas of reepithelialization distributed throughout the wound bed. By postoperative day 26, the patient had significantly more areas of wound closure and was discharged. Reepithelialization and repigmentation continued, and long-term follow-up after 26 months demonstrated complete reepithelialization and nearly complete repigmentation, without the appearance of contractures or hypertrophic scarring. This case report highlights the use of FBC as a scaffold capable of dermal regeneration and spontaneous reepithelialization with an excellent long-term functional and cosmetic outcome. PMID:25494213

  1. Accuracy of magnetic resonance imaging to detect cartilage loss in severe osteoarthritis of the first carpometacarpal joint: comparison with histological evaluation.

    PubMed

    Saltzherr, Michael S; Coert, J Henk; Selles, Ruud W; van Neck, Johan W; Jaquet, Jean-Bart; van Osch, Gerjo J V M; Oei, Edwin H G; Luime, Jolanda J; Muradin, Galied S R

    2017-03-14

    Magnetic resonance imaging (MRI) is increasingly used for research in hand osteoarthritis, but imaging the thin cartilage layers in the hand joints remains challenging. We therefore assessed the accuracy of MRI in detecting cartilage loss in patients with symptomatic osteoarthritis of the first carpometacarpal (CMC1) joint. Twelve patients scheduled for trapeziectomy to treat severe symptomatic osteoarthritis of the CMC1 joint underwent a preoperative high resolution 3D spoiled gradient (SPGR) MRI scan. Subsequently, the resected trapezium was evaluated histologically. The sections were scored for cartilage damage severity (Osteoarthritis Research Society International (OARSI) score), and extent of damage (percentage surface area). Each MRI scan was scored for the area of normal cartilage, partial cartilage loss and full cartilage loss. The percentages of the total surface area with any cartilage loss and full-thickness cartilage loss were calculated using MRI and histological evaluation. MRI and histological evaluation both identified large areas of overall cartilage loss. The median (IQR) surface area of any cartilage loss on MRI was 98% (82-100%), and on histological assessment 96% (87-98%). However, MRI underestimated the extent of full-thickness cartilage loss. The median (IQR) surface area of full-thickness cartilage loss on MRI was 43% (22-70%), and on histological evaluation 79% (67-85%). The difference was caused by a thin layer of high signal on the articulating surface, which was interpreted as damaged cartilage on MRI but which was not identified on histological evaluation. Three-dimensional SPGR MRI of the CMC1 joint demonstrates overall cartilage damage, but underestimates full-thickness cartilage loss in patients with advanced osteoarthritis.

  2. A systematic review of online resources to support patient decision-making for full-thickness rectal prolapse surgery.

    PubMed

    Fowler, G E; Baker, D M; Lee, M J; Brown, S R

    2017-11-01

    The internet is becoming an increasingly popular resource to support patient decision-making outside of the clinical encounter. The quality of online health information is variable and largely unregulated. The aim of this study was to assess the quality of online resources to support patient decision-making for full-thickness rectal prolapse surgery. This systematic review was registered on the PROSPERO database (CRD42017058319). Searches were performed on Google and specialist decision aid repositories using a pre-defined search strategy. Sources were analysed according to three measures: (1) their readability using the Flesch-Kincaid Reading Ease score, (2) DISCERN score and (3) International Patient Decision Aids Standards (IPDAS) minimum standards criteria score (IPDASi, v4.0). Overall, 95 sources were from Google and the specialist decision aid repositories. There were 53 duplicates removed, and 18 sources did not meet the pre-defined eligibility criteria, leaving 24 sources included in the full-text analysis. The mean Flesch-Kincaid Reading Ease score was higher than recommended for patient education materials (48.8 ± 15.6, range 25.2-85.3). Overall quality of sources supporting patient decision-making for full-thickness rectal prolapse surgery was poor (median DISCERN score 1/5 ± 1.18, range 1-5). No sources met minimum decision-making standards (median IPDASi score 5/12 ± 2.01, range 1-8). Currently, easily accessible online health information to support patient decision-making for rectal surgery is of poor quality, difficult to read and does not support shared decision-making. It is recommended that professional bodies and medical professionals seek to develop decision aids to support decision-making for full-thickness rectal prolapse surgery.

  3. 3D printing of novel osteochondral scaffolds with graded microstructure

    NASA Astrophysics Data System (ADS)

    Nowicki, Margaret A.; Castro, Nathan J.; Plesniak, Michael W.; Zhang, Lijie Grace

    2016-10-01

    Osteochondral tissue has a complex graded structure where biological, physiological, and mechanical properties vary significantly over the full thickness spanning from the subchondral bone region beneath the joint surface to the hyaline cartilage region at the joint surface. This presents a significant challenge for tissue-engineered structures addressing osteochondral defects. Fused deposition modeling (FDM) 3D bioprinters present a unique solution to this problem. The objective of this study is to use FDM-based 3D bioprinting and nanocrystalline hydroxyapatite for improved bone marrow human mesenchymal stem cell (hMSC) adhesion, growth, and osteochondral differentiation. FDM printing parameters can be tuned through computer aided design and computer numerical control software to manipulate scaffold geometries in ways that are beneficial to mechanical performance without hindering cellular behavior. Additionally, the ability to fine-tune 3D printed scaffolds increases further through our investment casting procedure which facilitates the inclusion of nanoparticles with biochemical factors to further elicit desired hMSC differentiation. For this study, FDM was used to print investment-casting molds innovatively designed with varied pore distribution over the full thickness of the scaffold. The mechanical and biological impacts of the varied pore distributions were compared and evaluated to determine the benefits of this physical manipulation. The results indicate that both mechanical properties and cell performance improve in the graded pore structures when compared to homogeneously distributed porous and non-porous structures. Differentiation results indicated successful osteogenic and chondrogenic manipulation in engineered scaffolds.

  4. In vivo and in vitro studies of borate based glass micro-fibers for dermal repairing.

    PubMed

    Zhou, Jie; Wang, Hui; Zhao, Shichang; Zhou, Nai; Li, Le; Huang, Wenhai; Wang, Deping; Zhang, Changqing

    2016-03-01

    Full-thickness skin defects represent urgent clinical problem nowadays. Wound dressing materials are hotly needed to induce dermal reconstruction or to treat serious skin defects. In this study, the borate bioactive glass (BG) micro-fibers were fabricated and compared with the traditional material 45S5 Bioglass(®) (SiG) micro-fibers. The morphology, biodegradation and bioactivity of BG and SiG micro-fibers were investigated in vitro. The wound size reduction and angiogenic effects of BG and SiG micro-fibers were evaluated by the rat full-thickness skin defect model and Microfil technique in vivo. Results indicated that the BG micro-fibers showed thinner fiber diameter (1 μm) and better bioactivity than the SiG micro-fibers did. The ionic extracts of BG and SiG micro-fibers were not toxic to human umbilical vein endothelial cells (HUVECs). In vivo, the BG micro-fiber wound dressings obviously enhanced the formation of blood vessel, and resulted in a much faster wound size reduction than the SiG micro-fibers, or than the control groups, after 9 days application. The good skin defect reconstruction ability of BG micro-fibers contributed to the B element in the composition, which results in the better bioactivity and angiogenesis. As shown above, the novel bioactive borate glass micro-fibers are expected to provide a promising therapeutic alternative for dermal reconstruction or skin defect repair. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Local air gap thickness and contact area models for realistic simulation of human thermo-physiological response

    NASA Astrophysics Data System (ADS)

    Psikuta, Agnes; Mert, Emel; Annaheim, Simon; Rossi, René M.

    2018-02-01

    To evaluate the quality of new energy-saving and performance-supporting building and urban settings, the thermal sensation and comfort models are often used. The accuracy of these models is related to accurate prediction of the human thermo-physiological response that, in turn, is highly sensitive to the local effect of clothing. This study aimed at the development of an empirical regression model of the air gap thickness and the contact area in clothing to accurately simulate human thermal and perceptual response. The statistical model predicted reliably both parameters for 14 body regions based on the clothing ease allowances. The effect of the standard error in air gap prediction on the thermo-physiological response was lower than the differences between healthy humans. It was demonstrated that currently used assumptions and methods for determination of the air gap thickness can produce a substantial error for all global, mean, and local physiological parameters, and hence, lead to false estimation of the resultant physiological state of the human body, thermal sensation, and comfort. Thus, this model may help researchers to strive for improvement of human thermal comfort, health, productivity, safety, and overall sense of well-being with simultaneous reduction of energy consumption and costs in built environment.

  6. Topically applied connective tissue growth factor/CCN2 improves diabetic preclinical cutaneous wound healing: potential role for CTGF in human diabetic foot ulcer healing.

    PubMed

    Henshaw, F R; Boughton, P; Lo, L; McLennan, S V; Twigg, S M

    2015-01-01

    Topical application of CTGF/CCN2 to rodent diabetic and control wounds was examined. In parallel research, correlation of CTGF wound fluid levels with healing rate in human diabetic foot ulcers was undertaken. Full thickness cutaneous wounds in diabetic and nondiabetic control rats were treated topically with 1 μg rhCTGF or vehicle alone, on 2 consecutive days. Wound healing rate was observed on day 14 and wound sites were examined for breaking strength and granulation tissue. In the human study across 32 subjects, serial CTGF regulation was analyzed longitudinally in postdebridement diabetic wound fluid. CTGF treated diabetic wounds had an accelerated closure rate compared with vehicle treated diabetic wounds. Healed skin withstood more strain before breaking in CTGF treated rat wounds. Granulation tissue from CTGF treatment in diabetic wounds showed collagen IV accumulation compared with nondiabetic animals. Wound α-smooth muscle actin was increased in CTGF treated diabetic wounds compared with untreated diabetic wounds, as was macrophage infiltration. Endogenous wound fluid CTGF protein rate of increase in human diabetic foot ulcers correlated positively with foot ulcer healing rate (r = 0.406; P < 0.001). These data collectively increasingly substantiate a functional role for CTGF in human diabetic foot ulcers.

  7. Non-occlusive topical exposure of human skin in vitro as model for cytotoxicity testing of irritant compounds.

    PubMed

    Lönnqvist, Susanna; Briheim, Kristina; Kratz, Gunnar

    2016-02-01

    Testing of irritant compounds has traditionally been performed on animals and human volunteers. Animal testing should always be restricted and for skin irritancy mice and rabbits hold poor predictive value for irritant potential in humans. Irritant testing on human volunteers is restricted by the duration subjects can be exposed, and by the subjectivity of interpreting the visual signs of skin irritation. We propose an irritant testing system using viable human full thickness skin with the loss of cell viability in the exposed skin area as end point measurement. Skin was exposed to sodium dodecyl sulfate (SDS) at 20% concentration by non-occluded topical exposure to establish a positive control response and subsequent test compounds were statistically compared with the 20% SDS response. Cell viability and metabolism were measured with 3-(4,5-dimethyl-thiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The model presents correlation between increased concentration of SDS and decreased viability of cells in the exposed skin area (R(2) = 0.76). We propose the model to be used for cytotoxicity testing of irritant compounds. With fully intact barrier function, the model comprises all cells present in the skin with quantifiable end point measurement.

  8. 3D enamel thickness in Neandertal and modern human permanent canines.

    PubMed

    Buti, Laura; Le Cabec, Adeline; Panetta, Daniele; Tripodi, Maria; Salvadori, Piero A; Hublin, Jean-Jacques; Feeney, Robin N M; Benazzi, Stefano

    2017-12-01

    Enamel thickness figures prominently in studies of human evolution, particularly for taxonomy, phylogeny, and paleodietary reconstruction. Attention has focused on molar teeth, through the use of advanced imaging technologies and novel protocols. Despite the important results achieved thus far, further work is needed to investigate all tooth classes. We apply a recent approach developed for anterior teeth to investigate the 3D enamel thickness of Neandertal and modern human (MH) canines. In terms of crown size, the values obtained for both upper and lower unworn/slightly worn canines are significantly greater in Neandertals than in Upper Paleolithic and recent MH. The 3D relative enamel thickness (RET) is significantly lower in Neandertals than in MH. Moreover, differences in 3D RET values between the two groups appear to decrease in worn canines beginning from wear stage 3, suggesting that both the pattern and the stage of wear may have important effects on the 3D RET value. Nevertheless, the 3D average enamel thickness (AET) does not differ between the two groups. In both groups, 3D AET and 3D RET indices are greater in upper canines than in lower canines, and overall the enamel is thicker on the occlusal half of the labial aspect of the crown, particularly in MH. By contrast, the few early modern humans investigated show the highest volumes of enamel while for all other components of 3D enamel, thickness this group holds an intermediate position between Neandertals and recent MH. Overall, our study supports the general findings that Neandertals have relatively thinner enamel than MH (as also observed in molars), indicating that unworn/slightly worn canines can be successfully used to discriminate between the two groups. Further studies, however, are needed to understand whether these differences are functionally related or are the result of pleiotropic or genetic drift effects. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Adenomyomatous Polyp with Inverted Growth Pattern and Serosal Pseudoinvasion

    DTIC Science & Technology

    2016-09-25

    muscle with thick -walled vessels. We present a novel case of a 48-year old female with an adenomyomatous polyp with an unusual inverted growth pattern...displaying full- thickness pseudoinvasion beyond the serosal surface. Prior to surgery, imaging showed an infiltrative lesion suggestive of endometrial

  10. In vivo thickness and birefringence determination of the human retinal nerve fiber layer using polarization-sensitive optical coherence tomography.

    PubMed

    Cense, B; Chen, T C; de Boer, J F

    2006-01-01

    Thinning of the retinal nerve fiber layer and changes in retinal nerve fiber layer birefringence may both precede clinically detectable glaucomatous vision loss. We present in vivo thickness and depth-resolved birefringence measurements of the human retinal nerve fiber layer (RNFL) by use of polarization-sensitive optical coherence tomography (PS-OCT). Using a fiber-based PS-OCT setup real-time images of the human retina in vivo were recorded, co-registered with retinal video images of the location of PS-OCT scans. PS-OCT scans around the optic nerve head (ONH) of two healthy young volunteers were made using 10 concentric circles of increasing radius. Both the mean retinal nerve fiber layer thickness and mean retinal nerve fiber birefringence for each of 48 sectors on a circle were determined. The retinal nerve fiber layer thickness and birefringence varied as a function of sector around the ONH. Measured double pass phase retardation per unit depth values around the ONH range between 0.10 and 0.35 degrees/microm. The retinal nerve fiber layer becomes thinner with increasing distance from the ONH. In contrast, the birefringence does not vary significantly with increasing distance from the ONH.

  11. Reproducibility of flap thickness with IntraLase FS and Moria LSK-1 and M2 microkeratomes.

    PubMed

    Talamo, Jonathan H; Meltzer, Jeremy; Gardner, John

    2006-06-01

    To compare flap thickness reproducibility of the femtosecond laser and two mechanical microkeratomes. Flap thickness for all eyes was measured as the difference between the preoperative (day of surgery) full corneal thickness and post-flap creation central stromal bed thickness using ultrasonic pachymetry. Flap thickness values produced by three different microkeratome systems were compared for accuracy and reproducibility. For 99 flaps created using the IntraLase FS laser with an intended thickness of 110 microm, the mean achieved thickness was 119 +/- 12 microm (range: 82 to 149 microm). In 100 eyes treated with the Moria LSK-1 microkeratome with an intended flap thickness of 160 microm, the mean achieved thickness was 130 +/- 19 microm (range: 71 to 186 microm). In 135 eyes treated with the Moria M2 microkeratome with an intended flap thickness of 130 microm, mean thickness was 142 +/- 24 microm (range: 84 to 203 microm). The standard deviation and range of corneal flap thickness created with the IntraLase FS laser was significantly smaller than either mechanical microkeratome (P < .0001). When compared to two commonly used mechanical microkeratomes, mean achieved flap thickness was more reproducible with the IntraLase FS laser, reducing the comparative risk of overly thick flaps.

  12. Laser Corrective Surgery with Fractional Carbon Dioxide Laser Following Full-thickness Skin Grafts.

    PubMed

    Forbat, Emily; Ali, Faisal R; Mallipeddi, Raj; Al-Niaimi, Firas

    2017-01-01

    Full-thickness skin grafts (FTSGs) are frequently used to treat patients with burn injuries and to repair defects rendered by excisional (including Mohs) surgery. The evidence for corrective laser surgery after scar formation is well established. With regard to laser treatment of FTSG, the evidence is sparse. Laser treatment after FTSG is a novel concept, with minimal literature. We present a case series, one of the first to our knowledge, of the treatment of FTSG with fractional CO 2 laser in five patients after Mohs surgery.

  13. Radiopacity of different resin-based and conventional luting cements compared to human and bovine teeth.

    PubMed

    Pekkan, Gürel; Ozcan, Mutlu

    2012-02-03

    This study evaluated the radiopacity of different resin-based luting materials and compared the results to human and bovine dental hard tissues. Disc specimens (N=130, n=10 per group) (diameter: 6 mm, thickness: 1 mm) were prepared from 10 resin-based and 3 conventional luting cements. Human canine dentin (n=10), bovine enamel (n=10), bovine dentin (n=10) and Aluminium (Al) step wedge were used as references. The optical density values of each material were measured from radiographic images using a transmission densitometer. Al step wedge thickness and optical density values were plotted and equivalent Al thickness values were determined for radiopacity measurements of each material. The radiopacity values of conventional cements and two resin luting materials (Rely X Unicem and Variolink II), were significantly higher than that of bovine enamel that could be preferred for restorations cemented on enamel. Since all examined resin-based luting materials showed radiopacity values equivalent to or greater than that of human and bovine dentin, they could be considered suitable for the restorations cemented on dentin.

  14. The role of enamel thickness and refractive index on human tooth colour.

    PubMed

    Oguro, Rena; Nakajima, Masatoshi; Seki, Naoko; Sadr, Alireza; Tagami, Junji; Sumi, Yasunori

    2016-08-01

    To investigate the role of enamel thickness and refractive index (n) on tooth colour. The colour and enamel thickness of fifteen extracted human central incisors were determined according to CIELab colour scale using spectrophotometer (Crystaleye) and swept-source optical coherence tomography (SS-OCT), respectively. Subsequently, labial enamel was trimmed by approximately 100μm, and the colour and remaining enamel thickness were investigated again. This cycle was repeated until dentin appeared. Enamel blocks were prepared from the same teeth and their n were obtained using SS-OCT. Multiple regression analysis was performed to reveal any effects of enamel thickness and n on colour difference (ΔE00) and differences in colour parameters with CIELCh and CIELab colour scales. Multiple regression analysis revealed that enamel thickness (p=0.02) and n of enamel (p<0.001) were statistically significant predictors of ΔE00 after complete enamel trimming. The n was also a significant predictor of ΔH' (p=0.01). Enamel thickness and n were not statistically significant predictors of ΔL', ΔC', Δa* and Δb*. Enamel affected tooth colour, in which n was a statistically significant predictor for tooth colour change. Understanding the role of enamel in tooth colour could contribute to development of aesthetic restorative materials that mimic the colour of natural tooth with minimal reduction of the existing enamel. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Genetically modified porcine split-thickness skin grafts as an alternative to allograft for provision of temporary wound coverage: preliminary characterization.

    PubMed

    Leto Barone, Angelo A; Mastroianni, Melissa; Farkash, Evan A; Mallard, Christopher; Albritton, Alexander; Torabi, Radbeh; Leonard, David A; Kurtz, Josef M; Sachs, David H; Cetrulo, Curtis L

    2015-05-01

    Temporary coverage of severely burned patients with cadaver allograft skin represents an important component of burn care, but is limited by availability and cost. Porcine skin shares many physical properties with human skin, but is susceptible to hyperacute rejection due to preformed antibodies to α-1,3-galactose (Gal), a carbohydrate on all porcine cells. Our preliminary studies have suggested that skin grafts from α-1,3-galactosyltransferase knock out (GalT-KO) miniature swine might provide temporary wound coverage comparable to allografts, since GalT-KO swine lack this carbohydrate. To further evaluate this possibility, eight non-human primates received primary autologous, allogeneic, GalT-KO, and GalT+xenogeneic skin grafts. Additionally, secondary grafts were placed to assess whether sensitization would affect the rejection time course of identical-type grafts. We demonstrate that both GalT-KO xenografts and allografts provide temporary coverage of partial- and full-thickness wounds for up to 11 days. In contrast, GalT+xenografts displayed hyperacute rejection, with no signs of vascularization and rapid avulsion from wounds. Furthermore, secondary GalT-KO transplants failed to vascularize, demonstrating that primary graft rejection sensitizes the recipient. We conclude that GalT-KO xenografts may provide temporary coverage of wounds for a duration equivalent to allografts, and thus, could serve as a readily available alternative treatment of severe burns. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  16. Silk fibroin produced by transgenic silkworms overexpressing the Arg-Gly-Asp motif accelerates cutaneous wound healing in mice.

    PubMed

    Baba, Atsunori; Matsushita, Shigeto; Kitayama, Kasumi; Asakura, Tetsuo; Sezutsu, Hideki; Tanimoto, Akihide; Kanekura, Takuro

    2018-03-04

    We investigated the effect of silk fibroin (SF) on wound healing in mice. SF or an amorphous SF film (ASFF) prepared from silk produced by the wild-type silkworm Bombyx mori (WT-SF, WT-ASFF) or by transgenic worms that overexpress the Arg-Gly-Asp (RGD) sequence (TG-SF, TG-ASFF) was placed on 5-mm diameter full-thickness skin wounds made by biopsy punch on the back of 8-12 week-old BALB/c mice. Each wound was covered with WT-ASFF and urethane film (UF), TG-ASFF plus UF, or UF alone (control). Wound closure, histological thickness, the area of granulation tissue, and neovascularization were analyzed 4, 8, and 12 days later. The effect of SF on cell migration and proliferation was examined in vitro by scratch- and MTT-assay using human dermal fibroblasts. Wound closure was prompted by TG-ASFF, granulation tissue was thicker and larger in ASFF-treated wounds than the control, and neovascularization was promoted significantly by WT-ASFF. Both assays showed that SF induced the migration and proliferation of human dermal fibroblasts. The effects of TG-ASFF and TG-SF on wound closure, granulation formation, and cell proliferation were more profound than that of WT-ASFF and WT-SF. We document that SF accelerates cutaneous wound healing, and this effect is enhanced with TG-SF. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018. © 2018 Wiley Periodicals, Inc.

  17. Effect of Fibrin Glue on the Biomechanical Properties of Human Descemet's Membrane

    PubMed Central

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Li, Ang; Poh, Rebekah; Tan, Xiao Wei; Lakshminarayanan, Rajamani; Lim, Chwee T.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Background Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK) to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK) performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10–15 µm in thickness), Descemet's membrane (DM) is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG) on the biomechanical properties of DM using atomic force microscopy (AFM) and relates these properties to membrane folding propensity. Methodology/Principal Findings Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the “rolling up” tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM) and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. Conclusions/Significance Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity. PMID:22662156

  18. 46 CFR 54.05-5 - Toughness test specimens.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... V-notch tests shall be conducted in accordance with ASTM Specification E 23 (incorporated by... for that thickness shall be cut centered at the material's mid-thickness. For materials thicker than 1/2-inch, full size Charpy specimens shall be cut centered at a location as near as practicable to a...

  19. Arctic and Antarctic sea-ice thickness from CryoSat and Envisat radar altimetry

    NASA Astrophysics Data System (ADS)

    Hendricks, S.; Rinne, E. J.; Paul, S.; Ricker, R.; Skourup, H.; Kern, S.; Sandven, S.

    2017-12-01

    One objective of the ESA Climate Change Initiative (CCI) on Sea Ice is the generation of a climate data record of sea-ice thickness from satellite radar altimetry in both hemispheres. We report on the results of the second phase of the CCI project, which are based on the15-year (2002-2017) monthly data record from Envisat and CryoSat-2 radar altimeter data. The data records needs to maintain consistency in the freeboard retrieval, freeboard to thickness conversion and uncertainty estimation for the full observational period. The main challenge has been to maintain consistency in the sea-ice freeboard retrieval due to the different radar altimeter concepts and footprints between Envisat and CryoSat-2. We have developed a novel empirical algorithm for both missions to minimize inter-mission biases for surface type classification as well as freeboard retrieval based on CryoSat reference data for the overlap period from November 2010 to March 2012. The parametrization takes differences between sea-ice surface properties in both hemisphere and the seasonal cycle into account. We report on the changes of sea-ice thickness in the Arctic winter seasons since 2002 and the comparison to independent freeboard and thickness observations. Far less validation data exists for the southern hemisphere and we provide an overview of changes and the expected skill of Antarctic sea ice thickness of the full seasonal cycle.

  20. Laser skin welding using water absorption and heat management

    NASA Astrophysics Data System (ADS)

    Halder, Rabindra K.; Katz, Alvin; Savage, Howard E.; Kartazayev, Vladimir; McCormick, Steven A.; Budansky, Yury; Paul, Misu; Rosen, Richard B.; Alfano, Robert R.

    2005-04-01

    Laser skin welding (LSW) is being pursued for scarless wound healing. We present a new LSW approach using a contact glass slide over the sample and rapid scanning of the laser beam around the area to be welded. This led to dramatic improvement in welding efficacy. A 400 mW beam at 1455 nm with a focused spot diameter of 80 μm in air was scanned at a rate of 5mm/second over a 5mm line of incision in 5 mm x 20 mm human skin samples. Histological analysis of the welded samples using hematoxyline and eosin under unpolarized light showed full-thickness full-length weld, and that with picrosirius red F3BA stain under polarized light revealed that there was no appreciable damage. Measured tensile strength of 2.1 kg/cm2 is markedly greater than our previous LSW results of 1.05 +/- 0.19 kg/cm2, which is greater than the typical values of 0.4 kg/cm2 obtained using sutures.

  1. Advanced therapies of skin injuries.

    PubMed

    Maver, Tina; Maver, Uroš; Kleinschek, Karin Stana; Raščan, Irena Mlinarič; Smrke, Dragica Maja

    2015-12-01

    The loss of tissue is still one of the most challenging problems in healthcare. Efficient laboratory expansion of skin tissue to reproduce the skins barrier function can make the difference between life and death for patients with extensive full-thickness burns, chronic wounds, or genetic disorders such as bullous conditions. This engineering has been initiated based on the acute need in the 1980s and today, tissue-engineered skin is the reality. The human skin equivalents are available not only as models for permeation and toxicity screening, but are frequently applied in vivo as clinical skin substitutes. This review aims to introduce the most important recent development in the extensive field of tissue engineering and to describe already approved, commercially available skin substitutes in clinical use.

  2. Modified Full Thickness Graded Blepharotomy for Upper Eyelid Retraction Associated With Thyroid Eye Disease in East Asians.

    PubMed

    Lee, Joonsik; Lee, Hwa; Park, Minsoo; Baek, Sehyun

    2016-12-01

    To evaluate the functional and cosmetic outcomes of modified full thickness graded blepharotomy when used for East Asian patients with upper eyelid retraction of thyroid eye disease (TED). Medical records of each patient who underwent modified full-thickness blepharotomy at Korea University Guro Hospitals from January 2009 to February 2014 to correct upper eyelid retraction resulting from TED were retrospectively reviewed. Modified full-thickness graded blepharotomies were performed on 22 eyelids of 18 patients. The most common preoperative upper eyelid retraction-associated symptom was asymmetry of the upper eyelid (14 patients, 77.7%) followed by discomfort (10 patients, 55.5%), photophobia (5 patients, 27.7%), and epiphora (4 patients, 22.2%). Most preoperative symptoms improved after blepharotomy (Table 1). Preoperatively, upper eyelid retraction (MRD1; midpupil marginal reflex distance) ranged from 2.3 mm to 6.8 mm (mean, 5.23 ± 0.89) in 22 lids; postoperatively, lid retraction significantly decreased to 3.26 ± 1.23 mm (P = 0.03 by independent t test) (Table 2). Lid retraction was divided into 3 groups according to severity; a severe group (5 eyelids, 27.7%), a moderate group (14 eyelids, 63.6%), and a mild group (3 eyelids, 13.6%). The MRD1 improved regardless of severity (P = 0.03 in the severe group, P = 0.02 in the moderate group, and P = 0.04 in the mild group by independent t test). The MRD1 improvement did not differ significantly among groups (P = 0.08 by Pearson χ t test). At 6 months postoperatively, the midpupil marginal reflex distance was the perfect height in 13 of 22 lids (59.0%), with a mean reduction of 3 mm, whereas 7 of 22 eyelids (31.8%) were at acceptable height and 2 eyelids (9.0%) showed failure. Overall, 18 eyelids (90.9%) exhibited objectively satisfactory results (perfect or acceptable) at 6 months after surgery (Table 3). Modified graded full thickness eyelid blepharotomy is a reliable and safe method for upper eyelid lengthening for East Asian patients with upper eyelid retraction of TED that offers excellent functional and cosmetic results.

  3. Closure of the Radial Forearm Free Flap Donor Site Using the Combined Local Triangular Full-Thickness Skin Graft.

    PubMed

    Moreno-Sánchez, Manuel; González-García, Raúl; Ruiz-Laza, Luis; Manzano Solo de Zaldívar, Damián; Moreno-García, Carlos; Monje, Florencio

    2016-01-01

    Traditional donor-site closure has been associated with serious esthetic and functional morbidity. The purpose of this study was to assess morbidity in esthetics and function and measure the postoperative complications of the radial forearm free flap (RFFF) donor site after using combined local triangular full-thickness skin grafting. This prospective study of patients who underwent reconstruction of head and neck defects using an RFFF was conducted from July 2008 through December 2014. The donor site was repaired with a combined local triangular full-thickness skin graft. Quality of the scar, color match, tendon exposure, presence of necrosis, dehiscence of the suture, and presence of dysesthesia were recorded and analyzed using SPSS 21.0 software. One hundred consecutive patients (71 male and 29 female) underwent RFFF harvesting. RFFF donor-site defects ranged from 15 to 70 cm2; partial skin graft loss occurred in 7% of patients. Five patients (5%) had small dehiscences of the forearm skin graft, and 2 cases (2%) presented tendon exposure. In all cases, these sites healed secondarily by conservative management, with no final impairment of function. Esthetic results were considered excellent in 87%, good in 11%, and suboptimal in 2% of the cases. The combined local triangular full-thickness skin graft is a reliable method for closing RFFF donor-site defects because it obviates a second surgical site, it provides excellent color match and pliability, and it can be used for covering large defects of the donor site. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study.

    PubMed

    Clay, L; Stark, B; Gunnarsson, U; Strigård, K

    2018-04-01

    Repair of large incisional hernias includes the implantation of a synthetic mesh, but this may lead to pain, stiffness, infection and enterocutaneous fistulae. Autologous full-thickness skin graft as on-lay reinforcement has been tested in eight high-risk patients in a proof-of-concept study, with satisfactory results. In this multicenter randomized study, the use of skin graft was compared to synthetic mesh in giant ventral hernia repair. Non-smoking patients with a ventral hernia > 10 cm wide were randomized to repair using an on-lay autologous full-thickness skin graft or a synthetic mesh. The primary endpoint was surgical site complications during the first 3 months. A secondary endpoint was patient comfort. Fifty-three patients were included. Clinical evaluation was performed at a 3-month follow-up appointment. There were fewer patients in the skin graft group reporting discomfort: 3 (13%) vs. 12 (43%) (p = 0.016). Skin graft patients had less pain and a better general improvement. No difference was seen regarding seroma; 13 (54%) vs. 13 (46%), or subcutaneous wound infection; 5 (20%) vs. 7 (25%). One recurrence appeared in each group. Three patients in the skin graft group and two in the synthetic mesh group were admitted to the intensive care unit. No difference was seen for the primary endpoint short-term surgical complication. Full-thickness skin graft appears to be a reliable material for ventral hernia repair producing no more complications than when using synthetic mesh. Patients repaired with a skin graft have less subjective abdominal wall symptoms.

  5. Rabbit cornea microstructure response to changes in intraocular pressure visualized by using nonlinear optical microscopy.

    PubMed

    Wu, Qiaofeng; Yeh, Alvin T

    2008-02-01

    To characterize the microstructural response of the rabbit cornea to changes in intraocular pressure (IOP) by using nonlinear optical microscopy (NLOM). Isolated rabbit corneas were mounted on an artificial anterior chamber in series with a manometer and were hydrostatically pressurized by a reservoir. The chamber was mounted on an upright microscope stage of a custom-built NLOM system for corneal imaging without using exogenous stains or dyes. Second harmonic generation in collagen was used to image through the full thickness of the central corneal stroma at IOPs between 5 and 20 mm Hg. Microstructural morphology changes as a function of IOP were used to characterize the depth-dependent response of the central cornea. Regional collagen lamellae architecture through the full thickness of the stroma was specifically imaged as a function of IOP. Hypotensive corneas showed gaps between lamellar structures that decreased in size with increasing IOP. These morphologic features appear to result from interwoven lamellae oriented along the anterior-posterior axis and parallel to the cornea surface. They appear throughout the full thickness and disappear with tension in the anterior but persist in the posterior central cornea, even at hypertensive IOP. NLOM reveals interwoven collagen lamellae sheets through the full thickness of the rabbit central cornea oriented along the anterior-posterior axis and parallel to the surface. The nondestructive nature of NLOM allows 3-dimensional imaging of stromal architecture as a function of IOP in situ. Collagen morphologic features were used as an indirect measure of depth-dependent mechanical response to changes in IOP.

  6. In vitro and in vivo assessment of lactic acid-modified chitosan scaffolds for potential treatment of full-thickness burns.

    PubMed

    Velasquillo, Cristina; Silva-Bermudez, Phaedra; Vázquez, Nadia; Martínez, Alan; Espadín, Andres; García-López, Julieta; Medina-Vega, Antonio; Lecona, Hugo; Pichardo-Baena, Raúl; Ibarra, Clemente; Shirai, Keiko

    2017-10-01

    Autologous skin transplantation is today's "gold standard" treatment for full-thickness burns. However, when > 30% of total body surface area is damaged, there is an important shortage of autologous donor sites for skin grafting; then, treatment alternatives become crucial. Such alternatives can be based on polymeric scaffolds capable of functioning as protective covers and cells/factors carriers. Chitosan (CTS) is a natural-derived polymer with relevant biological-related properties but poor mechanical performance. Improved mechanical properties can be achieved through lactic acid grafting (LA-g); nevertheless, LA-g affects the biological response towards the CTS-based materials. In this work, CTS-LA scaffolds with different LA-g percentages were synthesized and evaluated to determine appropriate LA-g degrees for full-thickness burns treatment. In vitro results indicated that the higher the LA-g percentage, the lower the capability of the scaffolds to sustain fibroblasts culture. Scaffolds with LA-g around 28% (CTS-LA28) sustained cell culture and allowed normal cell functionality. Further evaluation of CTS-LA28 as acellular and cellular grafts in a full-thickness burn mouse model showed that at 28 days post-burn, macroscopic characteristic of the reparation tissue were closer to healthy skin when cellular grafts were used for treatment; histological evaluation also showed that dermis cellularity and collagenous fibers structure were similar to those in healthy skin when cellular grafts were used for burns treatment. © 2017 Wiley Periodicals Inc. J Biomed Mater Res Part A: 105A: 2875-2891, 2017. © 2017 Wiley Periodicals, Inc.

  7. Using modern human cortical bone distribution to test the systemic robusticity hypothesis.

    PubMed

    Baab, Karen L; Copes, Lynn E; Ward, Devin L; Wells, Nora; Grine, Frederick E

    2018-06-01

    The systemic robusticity hypothesis links the thickness of cortical bone in both the cranium and limb bones. This hypothesis posits that thick cortical bone is in part a systemic response to circulating hormones, such as growth hormone and thyroid hormone, possibly related to physical activity or cold climates. Although this hypothesis has gained popular traction, only rarely has robusticity of the cranium and postcranial skeleton been considered jointly. We acquired computed tomographic scans from associated crania, femora and humeri from single individuals representing 11 populations in Africa and North America (n = 228). Cortical thickness in the parietal, frontal and occipital bones and cortical bone area in limb bone diaphyses were analyzed using correlation, multiple regression and general linear models to test the hypothesis. Absolute thickness values from the crania were not correlated with cortical bone area of the femur or humerus, which is at odds with the systemic robusticity hypothesis. However, measures of cortical bone scaled by total vault thickness and limb cross-sectional area were positively correlated between the cranium and postcranium. When accounting for a range of potential confounding variables, including sex, age and body mass, variation in relative postcranial cortical bone area explained ∼20% of variation in the proportion of cortical cranial bone thickness. While these findings provide limited support for the systemic robusticity hypothesis, cranial cortical thickness did not track climate or physical activity across populations. Thus, some of the variation in cranial cortical bone thickness in modern humans is attributable to systemic effects, but the driving force behind this effect remains obscure. Moreover, neither absolute nor proportional measures of cranial cortical bone thickness are positively correlated with total cranial bone thickness, complicating the extrapolation of these findings to extinct species where only cranial vault thickness has been measured. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Bayesian estimation of optical properties of the human head via 3D structural MRI

    NASA Astrophysics Data System (ADS)

    Barnett, Alexander H.; Culver, Joseph P.; Sorensen, A. Gregory; Dale, Anders M.; Boas, David A.

    2003-10-01

    Knowledge of the baseline optical properties of the tissues of the human head is essential for absolute cerebral oximetry, and for quantitative studies of brain activation. In this work we numerically model the utility of signals from a small 6-optode time-resolved diffuse optical tomographic apparatus for inferring baseline scattering and absorption coefficients of the scalp, skull and brain, when complete geometric information is available from magnetic resonance imaging (MRI). We use an optical model where MRI-segmented tissues are assumed homogeneous. We introduce a noise model capturing both photon shot noise and forward model numerical accuracy, and use Bayesian inference to predict errorbars and correlations on the measurments. We also sample from the full posterior distribution using Markov chain Monte Carlo. We conclude that ~ 106 detected photons are sufficient to measure the brain"s scattering and absorption to a few percent. We present preliminary results using a fast multi-layer slab model, comparing the case when layer thicknesses are known versus unknown.

  9. Wide-angle camera with multichannel architecture using microlenses on a curved surface.

    PubMed

    Liang, Wei-Lun; Shen, Hui-Kai; Su, Guo-Dung J

    2014-06-10

    We propose a multichannel imaging system that combines the principles of an insect's compound eye and the human eye. The optical system enables a reduction in track length of the imaging device to achieve miniaturization. The multichannel structure is achieved by a curved microlens array, and a Hypergon lens is used as the main lens to simulate the human eye, achieving large field of view (FOV). With this architecture, each microlens of the array transmits a segment of the overall FOV. The partial images are recorded in separate channels and stitched together to form the final image of the whole FOV by image processing. The design is 2.7 mm thick, with 59 channels; the 100°×80° full FOV is optimized using ZEMAX ray-tracing software on an image plane. The image plane size is 4.53  mm×3.29  mm. Given the recent progress in the fabrication of microlenses, this image system has the potential to be commercialized in the near future.

  10. Development of a tissue-engineered human oral mucosa equivalent based on an acellular allogeneic dermal matrix: a preliminary report of clinical application to burn wounds.

    PubMed

    Iida, Takuya; Takami, Yoshihiro; Yamaguchi, Ryo; Shimazaki, Shuji; Harii, Kiyonori

    2005-01-01

    Tissue-engineered skin equivalents composed of epidermal and dermal components have been widely investigated for coverage of full-thickness skin defects. We developed a tissue-engineered oral mucosa equivalent based on an acellular allogeneic dermal matrix and investigated its characteristics. We also tried and assessed its preliminary clinical application. Human oral mucosal keratinocytes were separated from a piece of oral mucosa and cultured in a chemically-defined medium. The keratinocytes were seeded on to the acellular allogeneic dermal matrix and cultured. Histologically, the mucosa equivalent had a well-stratified epithelial layer. Immunohistochemical study showed that it was similar to normal oral mucosa. We applied this equivalent in one case with an extensive burn wound. The equivalent was transplanted three weeks after the harvest of the patient's oral mucosa and about 30% of the graft finally survived. We conclude that this new oral mucosa equivalent could become a therapeutic option for the treatment of extensive burns.

  11. Clinical application of a tissue-cultured skin autograft: an alternative for the treatment of non-healing or slowly healing wounds?

    PubMed

    Zöller, Nadja; Valesky, Eva; Butting, Manuel; Hofmann, Matthias; Kippenberger, Stefan; Bereiter-Hahn, Jürgen; Bernd, August; Kaufmann, Roland

    2014-01-01

    The treatment regime of non-healing or slowly healing wounds is constantly improving. One aspect is surgical defect coverage whereby mesh grafts and keratinocyte suspension are applied. Tissue-cultured skin autografts may be an alternative for the treatment of full-thickness wounds and wounds that cover large areas of the body surface. Autologous epidermal and dermal cells were isolated, expanded in vitro and seeded on collagen-elastin scaffolds. The developed autograft was immunohistochemically characterized and subsequently transplanted onto a facial chronic ulceration of a 71-year-old patient with vulnerable atrophic skin. Characterization of the skin equivalent revealed comparability to healthy human skin due to the epidermal strata, differentiation and proliferation markers. Within 138 days, the skin structure at the transplantation site closely correlated with the adjacent undisturbed skin. The present study demonstrates the comparability of the developed organotypic skin equivalent to healthy human skin and the versatility for clinical applications.

  12. Real-time automated thickness measurement of the in vivo human tympanic membrane using optical coherence tomography

    PubMed Central

    Hubler, Zita; Shemonski, Nathan D.; Shelton, Ryan L.; Monroy, Guillermo L.; Nolan, Ryan M.

    2015-01-01

    Background Otitis media (OM), an infection in the middle ear, is extremely common in the pediatric population. Current gold-standard methods for diagnosis include otoscopy for visualizing the surface features of the tympanic membrane (TM) and making qualitative assessments to determine middle ear content. OM typically presents as an acute infection, but can progress to chronic OM, and after numerous infections and antibiotic treatments over the course of many months, this disease is often treated by surgically inserting small tubes in the TM to relieve pressure, enable drainage, and provide aeration to the middle ear. Diagnosis and monitoring of OM is critical for successful management, but remains largely qualitative. Methods We have developed an optical coherence tomography (OCT) system for high-resolution, depth-resolved, cross-sectional imaging of the TM and middle ear content, and for the quantitative assessment of in vivo TM thickness including the presence or absence of a middle ear biofilm. A novel algorithm was developed and demonstrated for automatic, real-time, and accurate measurement of TM thickness to aid in the diagnosis and monitoring of OM and other middle ear conditions. The segmentation algorithm applies a Hough transform to the OCT image data to determine the boundaries of the TM to calculate thickness. Results The use of OCT and this segmentation algorithm is demonstrated first on layered phantoms and then during real-time acquisition of in vivo OCT from humans. For the layered phantoms, measured thicknesses varied by approximately 5 µm over time in the presence of large axial and rotational motion. In vivo data also demonstrated differences in thicknesses both spatially on a single TM, and across normal, acute, and chronic OM cases. Conclusions Real-time segmentation and thickness measurements of image data from both healthy subjects and those with acute and chronic OM demonstrate the use of OCT and this algorithm as a robust, quantitative, and accurate method for use during real-time in vivo human imaging. PMID:25694956

  13. Real-time automated thickness measurement of the in vivo human tympanic membrane using optical coherence tomography.

    PubMed

    Hubler, Zita; Shemonski, Nathan D; Shelton, Ryan L; Monroy, Guillermo L; Nolan, Ryan M; Boppart, Stephen A

    2015-02-01

    Otitis media (OM), an infection in the middle ear, is extremely common in the pediatric population. Current gold-standard methods for diagnosis include otoscopy for visualizing the surface features of the tympanic membrane (TM) and making qualitative assessments to determine middle ear content. OM typically presents as an acute infection, but can progress to chronic OM, and after numerous infections and antibiotic treatments over the course of many months, this disease is often treated by surgically inserting small tubes in the TM to relieve pressure, enable drainage, and provide aeration to the middle ear. Diagnosis and monitoring of OM is critical for successful management, but remains largely qualitative. We have developed an optical coherence tomography (OCT) system for high-resolution, depth-resolved, cross-sectional imaging of the TM and middle ear content, and for the quantitative assessment of in vivo TM thickness including the presence or absence of a middle ear biofilm. A novel algorithm was developed and demonstrated for automatic, real-time, and accurate measurement of TM thickness to aid in the diagnosis and monitoring of OM and other middle ear conditions. The segmentation algorithm applies a Hough transform to the OCT image data to determine the boundaries of the TM to calculate thickness. The use of OCT and this segmentation algorithm is demonstrated first on layered phantoms and then during real-time acquisition of in vivo OCT from humans. For the layered phantoms, measured thicknesses varied by approximately 5 µm over time in the presence of large axial and rotational motion. In vivo data also demonstrated differences in thicknesses both spatially on a single TM, and across normal, acute, and chronic OM cases. Real-time segmentation and thickness measurements of image data from both healthy subjects and those with acute and chronic OM demonstrate the use of OCT and this algorithm as a robust, quantitative, and accurate method for use during real-time in vivo human imaging.

  14. Simulation of Thermal Signature of Tires and Tracks

    DTIC Science & Technology

    2012-08-01

    the body-ply is a linear elastic material. To facilitate the analysis, the tire was divided into Tread and Sidewall by the dash line as shown in...only one element is assigned through the thickness of the tire . Therefore, the thickness of the element is the same as the thickness of the tire ...to the whole part of the 3D full tire in the thermal analysis. The average strain energy density for each part ( tread or sidewall) in the cross

  15. Aerodynamic Characteristics of a 14-Percent-Thick NASA Supercritical Airfoil Designed for a Normal-Force Coefficient of 0.7

    NASA Technical Reports Server (NTRS)

    Harris, C. D.

    1975-01-01

    This report documents the experimental aerodynamic characteristics of a 14 percent thick supercritical airfoil based on an off design sonic pressure plateau criterion. The design normal force coefficient was 0.7. The results are compared with those of the family related 10 percent thick supercritical airfoil 33. Comparisons are also made between experimental and theoretical characteristics and composite drag rise characteristics derived for a full scale Reynolds number of 40 million.

  16. Ballistic Simulation Method for Lithium Ion Batteries (BASIMLIB) Using Thick Shell Composites (TSC) in LS-DYNA

    DTIC Science & Technology

    2016-08-04

    BAllistic SImulation Method for Lithium Ion Batteries (BASIMLIB) using Thick Shell Composites (TSC) in LS-DYNA Venkatesh Babu, Dr. Matt Castanier, Dr...Objective • Objective and focus of this work is to develop a – Robust simulation methodology to model lithium - ion based batteries in its module and full...unlimited  Lithium Ion Phosphate (LiFePO4) battery cell, module and pack was modeled in LS-DYNA using both Thin Shell Layer (TSL) and Thick Shell

  17. Fractional Skin Harvesting: Autologous Skin Grafting without Donor-site Morbidity

    PubMed Central

    Wang, Ying; Farinelli, William A.; Jiménez-Lozano, Joel; Franco, Walfre; Sakamoto, Fernanda H.; Cheung, Evelyn J.; Purschke, Martin; Doukas, Apostolos G.; Anderson, R. Rox

    2013-01-01

    Background: Conventional autologous skin grafts are associated with significant donor-site morbidity. This study was conducted to determine feasibility, safety, and efficacy of a new strategy for skin grafting based on harvesting small columns of full-thickness skin with minimal donor-site morbidity. Methods: The swine model was used for this study. Hundreds of full-thickness columns of skin tissue (~700 µm diameter) were harvested using a custom-made harvesting device, and then applied directly to excisional skin wounds. Healing in donor and graft sites was evaluated over 3 months by digital photographic measurement of wound size and blinded, computer-aided evaluation of histological features and compared with control wounds that healed by secondary intention or with conventional split-thickness skin grafts (STSG). Results: After harvesting hundreds of skin columns, the donor sites healed rapidly without scarring. These sites reepithelialized within days and were grossly and histologically indistinguishable from normal skin within 7 weeks. By contrast, STSG donor sites required 2 weeks for reepithelialization and retained scar-like characteristics in epidermal and dermal architecture throughout the experiment. Wounds grafted with skin columns resulted in accelerated reepithelialization compared with ungrafted wounds while avoiding the “fish-net” patterning caused by STSG. Conclusion: Full-thickness columns of skin can be harvested in large quantities with negligible long-term donor-site morbidity, and these columns can be applied directly to skin wounds to enhance wound healing. PMID:25289241

  18. Effects of spatial variation of skull and cerebrospinal fluid layers on optical mapping of brain activities

    NASA Astrophysics Data System (ADS)

    Wang, Shuping; Shibahara, Nanae; Kuramashi, Daishi; Okawa, Shinpei; Kakuta, Naoto; Okada, Eiji; Maki, Atsushi; Yamada, Yukio

    2010-07-01

    In order to investigate the effects of anatomical variation in human heads on the optical mapping of brain activity, we perform simulations of optical mapping by solving the photon diffusion equation for layered-models simulating human heads using the finite element method (FEM). Particularly, the effects of the spatial variations in the thicknesses of the skull and cerebrospinal fluid (CSF) layers on mapping images are investigated. Mapping images of single active regions in the gray matter layer are affected by the spatial variations in the skull and CSF layer thicknesses, although the effects are smaller than those of the positions of the active region relative to the data points. The increase in the skull thickness decreases the sensitivity of the images to active regions, while the increase in the CSF layer thickness increases the sensitivity in general. The images of multiple active regions are also influenced by their positions relative to the data points and by their depths from the skin surface.

  19. Thickness and resistivity variations over the upper surface of the human skull.

    PubMed

    Law, S K

    1993-01-01

    A study of skull thickness and resistivity variations over the upper surface was made for an adult human skull. Physical measurements of thickness and qualitative analysis of photographs and CT scans of the skull were performed to determine internal and external features of the skull. Resistivity measurements were made using the four-electrode method and ranged from 1360 to 21400 Ohm-cm with an overall mean of 7560 +/- 4130 Ohm-cm. The presence of sutures was found to decrease resistivity substantially. The absence of cancellous bone was found to increase resistivity, particularly for samples from the temporal bone. An inverse relationship between skull thickness and resistivity was determined for trilayer bone (n = 12, p < 0.001). The results suggest that the skull cannot be considered a uniform layer and that local resistivity variations should be incorporated into realistic geometric and resistive head models to improve resolution in EEG. Influences of these variations on head models, methods for determining these variations, and incorporation into realistic head models, are discussed.

  20. Tailoring automatic exposure control toward constant detectability in digital mammography.

    PubMed

    Salvagnini, Elena; Bosmans, Hilde; Struelens, Lara; Marshall, Nicholas W

    2015-07-01

    The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. The default "opdose" AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d'), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (Tt) in the European guidelines for the 0.1 mm diameter disc (i.e., Tt ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (Tt), calculated detectability (d'), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. The default opdose AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d' 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d'), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default AEC mode in the homogeneous background increased by 62% in going from 20 to 70 mm PMMA thickness; in the structured background, the increase was 39%. Implementation of the modified mode entailed an increase in mAs at PMMA thicknesses >40 mm; the modified AEC held threshold gold thickness constant above 40 mm PMMA with a maximum deviation of 5% in the homogeneous background and 3% in structured background. SDNR was also held constant with a maximum deviation of 4% and 2% for the homogeneous and the structured background, respectively. These results were obtained with an increase of MGD between 15% and 73% going from 40 to 70 mm PMMA thickness. This work has proposed and implemented a modified AEC mode, tailored toward constant detectability at larger breast thickness, i.e., above 40 mm PMMA equivalent. The desired improvement in object detectability could be obtained while maintaining MGD within the European guidelines achievable dose limit. (A study designed to verify the performance of the modified mode using more clinically realistic data is currently underway.).

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salvagnini, Elena, E-mail: elena.salvagnini@uzleuven.be; Bosmans, Hilde; Struelens, Lara

    Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settingsmore » were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default AEC mode in the homogeneous background increased by 62% in going from 20 to 70 mm PMMA thickness; in the structured background, the increase was 39%. Implementation of the modified mode entailed an increase in mAs at PMMA thicknesses >40 mm; the modified AEC held threshold gold thickness constant above 40 mm PMMA with a maximum deviation of 5% in the homogeneous background and 3% in structured background. SDNR was also held constant with a maximum deviation of 4% and 2% for the homogeneous and the structured background, respectively. These results were obtained with an increase of MGD between 15% and 73% going from 40 to 70 mm PMMA thickness. Conclusions: This work has proposed and implemented a modified AEC mode, tailored toward constant detectability at larger breast thickness, i.e., above 40 mm PMMA equivalent. The desired improvement in object detectability could be obtained while maintaining MGD within the European guidelines achievable dose limit. (A study designed to verify the performance of the modified mode using more clinically realistic data is currently underway.)« less

  2. Investigation of Natural and Man-Made Radiation Effects on Crews on Long Duration Space Missions

    NASA Technical Reports Server (NTRS)

    Bolch, Wesley E.; Parlos, Alexander

    1996-01-01

    Over the past several years, NASA has studied a variety of mission scenarios designed to establish a permanent human presence on the surface of Mars. Nuclear electric propulsion (NEP) is one of the possible elements in this program. During the initial stages of vehicle design work, careful consideration must be given to not only the shielding requirements of natural space radiation, but to the shielding and configuration requirements of the on-board reactors. In this work, the radiation transport code MCNP has been used to make initial estimates of crew exposures to reactor radiation fields for a specific manned NEP vehicle design. In this design, three 25 MW(sub th), scaled SP-100-class reactors are shielded by three identical shields. Each shield has layers of beryllium, tungsten, and lithium hydride between the reactor and the crew compartment. Separate calculations are made of both the exiting neutron and gamma fluxes from the reactors during beginning-of-life, full-power operation. This data is then used as the source terms for particle transport in MCNP. The total gamma and neutron fluxes exiting the reactor shields are recorded and separate transport calculations are then performed for a 10 g/sq cm crew compartment aluminum thickness. Estimates of crew exposures have been assessed for various thicknesses of the shield tungsten and lithium hydride layers. A minimal tungsten thickness of 20 cm is required to shield the reactor photons below the 0.05 Sv/y man-made radiation limit. In addition to a 20-cm thick tungsten layer, a 40-cm thick lithium hydride layer is required to shield the reactor neutrons below the annual limit. If the tungsten layer is 30-cm thick, the lithium hydride layer should be at least 30-cm thick. These estimates do not take into account the photons generated by neutron interactions inside the shield because the MCNP neutron cross sections did not allow reliable estimates of photon production in these materials. These results, along with natural space radiation shielding estimates calculated by NASA Langley Research Center, have been used to provide preliminary input data into a new Macintosh-based software tool. A skeletal version of this tool being developed will allow rapid radiation exposure and risk analyses to be performed on a variety of Lunar and Mars missions utilizing nuclear-powered vehicles.

  3. High vancomycin MICs within the susceptible range in Staphylococcus aureus bacteraemia isolates are associated with increased cell wall thickness and reduced intracellular killing by human phagocytes.

    PubMed

    Falcón, Rocío; Martínez, Alba; Albert, Eliseo; Madrid, Silvia; Oltra, Rosa; Giménez, Estela; Soriano, Mario; Vinuesa, Víctor; Gozalbo, Daniel; Gil, María Luisa; Navarro, David

    2016-05-01

    Vancomycin minimum inhibitory concentrations (MICs) at the upper end of the susceptible range for Staphylococcus aureus have been associated with poor clinical outcomes of bloodstream infections. We tested the hypothesis that high vancomycin MICs in S. aureus bacteraemia isolates are associated with increased cell wall thickness and suboptimal bacterial internalisation or lysis by human phagocytes. In total, 95 isolates were evaluated. Original vancomycin MICs were determined by Etest. The susceptibility of S. aureus isolates to killing by phagocytes was assessed in a human whole blood assay. Internalisation of bacterial cells by phagocytes was investigated by flow cytometry. Cell wall thickness was evaluated by transmission electron microscopy. Genotypic analysis of S. aureus isolates was performed using a DNA microarray system. Vancomycin MICs were significantly higher (P=0.006) in isolates that were killed suboptimally (killing index <60%) compared with those killed efficiently (killing index >70%) and tended to correlate inversely (P=0.08) with the killing indices. Isolates in both killing groups were internalised by human neutrophils and monocytes with comparable efficiency. The cell wall was significantly thicker (P=0.03) in isolates in the low killing group. No genotypic differences were found between the isolates in both killing groups. In summary, high vancomycin MICs in S. aureus bacteraemia isolates were associated with increased cell wall thickness and reduced intracellular killing by phagocytes. Copyright © 2016 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  4. In vivo measurements of cutaneous melanin across spatial scales: using multiphoton microscopy and spatial frequency domain spectroscopy.

    PubMed

    Saager, Rolf B; Balu, Mihaela; Crosignani, Viera; Sharif, Ata; Durkin, Anthony J; Kelly, Kristen M; Tromberg, Bruce J

    2015-06-01

    The combined use of nonlinear optical microscopy and broadband reflectance techniques to assess melanin concentration and distribution thickness in vivo over the full range of Fitzpatrick skin types is presented. Twelve patients were measured using multiphoton microscopy (MPM) and spatial frequency domain spectroscopy (SFDS) on both dorsal forearm and volar arm, which are generally sun-exposed and non-sun-exposed areas, respectively. Both MPM and SFDS measured melanin volume fractions between (skin type I non-sun-exposed) and 20% (skin type VI sun exposed). MPM measured epidermal (anatomical) thickness values ~30-65 μm, while SFDS measured melanin distribution thickness based on diffuse optical path length. There was a strong correlation between melanin concentration and melanin distribution (epidermal) thickness measurements obtained using the two techniques. While SFDS does not have the ability to match the spatial resolution of MPM, this study demonstrates that melanin content as quantified using SFDS is linearly correlated with epidermal melanin as measured using MPM (R² = 0.8895). SFDS melanin distribution thickness is correlated to MPM values (R² = 0.8131). These techniques can be used individually and/or in combination to advance our understanding and guide therapies for pigmentation-related conditions as well as light-based treatments across a full range of skin types.

  5. Hot asphalt burns: a review of injuries and management options.

    PubMed

    Bosse, George M; Wadia, Shernaz A; Padmanabhan, Pradeep

    2014-07-01

    Hot asphalt burns to human tissue can increase the likelihood of infection and potential conversion of partial thickness to full-thickness injuries. Successful intervention for hot asphalt burns requires immediate and effective cooling of the asphalt on the tissue followed by subsequent gradual removal of the cooled asphalt. A review of the literature reveals that multiple substances have been used to remove asphalt, including topical antibiotics, petroleum jelly, a commercial product known as De-Solv-It (ORANGE-SOL, Chandler, AZ), sunflower oil, baby oil, liquid paraffin, butter, mayonnaise, and moist-exposed burn ointment (MEBO). Although many of these products may be effective in the removal of asphalt, they may not be readily available in an emergency department setting. Topical antibiotics are readily available, are more commonly described in the medical literature, and would be expected to be effective in the removal of asphalt. We developed guidelines for on scene (first-aid) management and the initial care of such patients upon presentation to a health care facility. These guidelines emphasize the principles of early cooling, gradual removal of adherent asphalt using topical antibiotics, and avoidance of the use of topical agents, which are likely to result in tissue toxicity.

  6. Sporotrichoid Mycobacterium marinum infection of the face following a cat scratch.

    PubMed

    Phan, Tai Anh; Relic, John

    2010-02-01

    Mycobacterium marinum infections in humans uncommonly affect the face and are not known to be associated with cat scratches. We describe a 24-year-old woman who presented with a 3-month history of multiple tender, occasionally discharging cystic nodules involving the left side of her face in a sporotrichoid distribution. She had suffered a cat scratch to her left lower eyelid 3 weeks before the onset of the eruption and owned multiple tropical fish tanks. She was systemically well and had no lymphadenopathy. She had a background history of a 4.5-mm-thick nodular melanoma of her temple treated by wide local excision and negative sentinel lymph node biopsy 4 years prior. Skin biopsies showed multiple variably sized granulomas surrounded by thick cuffs of lymphocytes involving the superficial and deep dermis with no organisms seen on Ziehl-Neelsen, peroidic acid-Schiff and methenamine silver stains. Laboratory investigations showed a mildly raised erythrocyte sedimentation rate but normal full blood count and C-reactive protein. Fluid from the left cheek grew an acid-fast bacillus identified as Mycobacterium marinum. The skin eruption cleared after 5-month treatment with oral clarithromycin 500 mg twice daily and rifampicin 600 mg daily.

  7. A Study on Ultraviolet Protection of 100% Cotton Knitted Fabric: Effect of Fabric Parameters

    PubMed Central

    Kan, C. W.

    2014-01-01

    The effect of fabric parameters such as weight, thickness, and stitch density on the ultraviolet (UV) protection of knitted fabrics was studied. Different knitting structures such as plain, pineapple, lacoste, and other combinations of different knitting stitches of knit, tuck, and miss as well as half milano, full milano, half cardigan, full cardigan, 1 × 1 rib, and interlock were prepared. Experimental results revealed that weight was the most important factor that affected UV protection while thickness and stitch density were not the leading factor in determining UV protection. PMID:24955409

  8. Facial resurfacing with a monoblock full-thickness skin graft after multiple malignant melanomas excision in xeroderma pigmentosum.

    PubMed

    Ozmen, Selahattin; Uygur, Safak; Eryilmaz, Tolga; Ak, Betul

    2012-09-01

    Xeroderma pigmentosum is an autosomal recessive disease, characterized by vulnerability of the skin to solar radiation. Increase in sunlight-induced cancer is a direct consequence of an increase in mutated cells of the skin of patients with xeroderma pigmentosum. There is no specific technique for facial resurfacing in patients with xeroderma pigmentosum. In this article, a patient with xeroderma pigmentosum with multiple malignant melanomas on her face and radical excision of total facial skin followed by facial resurfacing with monoblock full-thickness skin graft from the abdomen is presented.

  9. Real-time sonography to estimate muscle thickness: comparison with MRI and CT.

    PubMed

    Dupont, A C; Sauerbrei, E E; Fenton, P V; Shragge, P C; Loeb, G E; Richmond, F J

    2001-05-01

    We investigated the feasibility of using real-time sonography to measure muscle thickness. Clinically, this technique would be used to measure the thickness of human muscles in which intramuscular microstimulators have been implanted to treat or prevent disuse atrophy. Porcine muscles were implanted with microstimulators and imaged with sonography, MRI, and CT to assess image artifacts created by the microstimulators and to design protocols for image alignment between methods. Sonography and MRI were then used to image the deltoid and supraspinatus muscles of 6 healthy human subjects. Microstimulators could be imaged with all 3 methods, producing only small imaging artifacts. Muscle-thickness measurements agreed well between methods, particularly when external markers were used to precisely align the imaging planes. The correlation coefficients for sonographic and MRI measurements were 0.96 for the supraspinatus and 0.97 for the deltoid muscle. Repeated sonographic measurements had a low coefficient of variation: 2.3% for the supraspinatus and 3.1% for the deltoid muscle. Real-time sonography is a relatively simple and inexpensive method of accurately measuring muscle thickness as long as the operator adheres to a strict imaging protocol and avoids excessive pressure with the transducer. Copyright 2001 John Wiley & Sons, Inc.

  10. The incidence and effect of fatty atrophy, positive tangent sign, and rotator cuff tears on outcomes after total shoulder arthroplasty.

    PubMed

    Choate, W Stephen; Shanley, Ellen; Washburn, Richard; Tolan, Stefan J; Salim, Tariq I; Tadlock, Josh; Shealy, Elizabeth C; Long, Catherine D; Crawford, Ashley E; Kissenberth, Michael J; Lonergan, Keith T; Hawkins, Richard J; Tokish, John M

    2017-12-01

    Treatment choices for total shoulder arthroplasty (TSA) in the absence of full-thickness rotator cuff tears (RCTs) are not clearly defined in current literature. This study investigated the prevalence and effect of preoperative partial-thickness RCTs and muscular degenerative changes on postoperative outcomes after TSA. Medical records and magnetic resonance imaging studies were reviewed for patients who underwent TSA for primary glenohumeral osteoarthritis with minimum 2-year follow-up to determine preoperative tear classification, Goutallier grade, and supraspinatus tangent sign. Postoperative pain on the visual analog scale, range of motion, and patient outcomes scores were obtained to correlate preoperative RCT status, Goutallier grading, tangent sign, and postoperative outcomes. Patients with full-thickness RCT on preoperative magnetic resonance imaging were excluded. Forty-five patients met all inclusion criteria (average age, 65 ± 10 years; average follow-up, 43 months). Of the patients undergoing TSA, 40% had a significant (>50% thickness) partial RCT. Grade 3 to 4 Goutallier changes were noted in 22% of all patients, and 13% demonstrated grade 3 to 4 changes in the context of no tear. Positive tangent sign was present in 7% of all patients. The preoperative Goutallier grade of the infraspinatus was significantly negatively correlated with postoperative forward elevation (P = .02) and external rotation (P = .05), but rotator cuff pathology, including tear status, Goutallier grade, and the presence of a tangent sign, did not correlate with postoperative functional outcome scores. Even in the absence of a full-thickness RCT, rotator cuff atrophy, fatty infiltration, and partial thickness tearing are common findings. Although postoperative range of motion is correlated to Goutallier changes of the infraspinatus, rotator cuff pathology is not correlated to outcomes after TSA; therefore, one may proceed with TSA without concern of their effect on postoperative outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Evaluation of cytotoxicity and antimicrobial activity of Acticoat Burn Dressing for management of microbial contamination in cultured skin substitutes grafted to athymic mice.

    PubMed

    Supp, Andrew P; Neely, Alice N; Supp, Dorothy M; Warden, Glenn D; Boyce, Steven T

    2005-01-01

    Cultured skin substitutes (CSS) have become a useful adjunctive treatment for closure of burn wounds, but CSS are avascular and remain susceptible to microbial destruction longer than split-thickness skin grafts. Irrigation of CSS grafted to burn wounds with a topical antimicrobial solution (TAS) has been shown to promote engraftment of CSS, but TAS usage has potential limitations. Acticoat Burn Dressing (Acticoat; Westaim Biomedical, Exeter, NH) is a silver-coated barrier dressing reported to exhibit antimicrobial activity and to reduce infection in partial-thickness and full-thickness wounds. This study evaluated the cytotoxicity of Acticoat with CSS and the efficacy of Acticoat for the management of microbial contamination in CSS grafted to full-thickness wounds in athymic mice. The cytotoxicity of Acticoat was assessed in preliminary studies after 1 week of exposure to CSS during in vitro maturation or healing on wounds in athymic mice. Histologies were analyzed and cellular viability in the CSS was determined by MTT conversion on days 0, 1, and 7 of Acticoat exposure. At 1, 2, 3, and 4 weeks after grafting, wounds were traced, and areas of healing CSS were calculated by image analysis. At 4 weeks, wound biopsies were evaluated and scored for engraftment of human cells. In a subsequent study, wounds were inoculated with strain SBI-N of Pseudomonas aeruginosa at 1 x 10(5) cfu/wound before the application of CSS or inoculated onto the surface of Acticoat. At 4 weeks, swab cultures were collected from the surface of CSS and scored for the presence of SBI-N. Statistical significance was accepted at the 95% confidence level (P <.05). The data show that exposure in vitro of CSS to Acticoat was cytotoxic within 1 day, but 1 week of exposure in vivo did not injure CSS or inhibit wound healing. Contaminated wounds treated with Acticoat healed similarly to control treatments, with comparable rates of engraftment, and detection of SBI-N on the surface of only one graft. No SBI-N was detected on CSS after inoculation onto the surface of Acticoat. These results suggest that Acticoat may be suitable as a protective dressing to reduce environmental contamination of CSS, if used in conjunction with additional antimicrobials to control organisms present in the wound.

  12. Grid removal and impact on population dose in full-field digital mammography.

    PubMed

    Gennaro, Gisella; Katz, Luc; Souchay, Henri; Klausz, Remy; Alberelli, Claudio; di Maggio, Cosimo

    2007-02-01

    The study purpose was to determine the impact of anti-scatter grid removal on patient dose, in full field digital mammography. Dose saving, phantom based, was evaluated with the constraint that images acquired with and without grid would provide the same contrast-to-noise ratio (CNR). The digital equipment employed a flat panel detector with cesium iodide for x-ray to light conversion, 100 microm pixel size; the x-ray source was a dual-track tube with selectable filtration. Poly(methyl-emathocrylate) (PMMA) layers in the range 20-70 mm were used to simulate the absorption of different breast thickness, while two Al foils, 0.1 and 0.2 mm thick were used to provide a certain CNR. Images with grid were acquired with the same beam quality as selected in full automatic exposure mode and the mAs levels as close as possible, and the CNR measured for each thickness between 20 and 70 mm. Phantom images without grid were acquired in manual exposure mode, by selecting the same anode/filter combination and kVp as the image with grid at the same thickness, but varying mAs from 10 to 200. For each thickness, an image without aluminum was acquired for each mAs value, in order to obtain a flat image to be used to subtract the scatter nonuniformity from the phantom images. After scatter subtraction, the CNR was measured on images without grid. The mAs value that should be set to acquire a phantom image without grid so that it has the same CNR as the corresponding grid image was calculated. Therefore, mAs reduction percentage was determined versus phantom thickness. Results showed that dose saving was lower than 30% for PMMA equivalent breast thinner than 40 mm, decreased below 10% for intermediate thickness (45-50 mm), but there was no dose gain for thickness beyond 60 mm. By applying the mAs reduction factors to a clinical population derived from a data base of 4622 breasts, dose benefit was quantified in terms of population dose. On the average, the overall dose reduction was about 8%. It was considered small, not sufficient to justify a clinical implementation, and the anti-scatter grid was maintained.

  13. Standardized Scalp Massage Results in Increased Hair Thickness by Inducing Stretching Forces to Dermal Papilla Cells in the Subcutaneous Tissue

    PubMed Central

    Kobayashi, Kazuhiro; Hama, Takanori; Murakami, Kasumi; Ogawa, Rei

    2016-01-01

    Objective: In this study, we evaluated the effect of scalp massage on hair in Japanese males and the effect of stretching forces on human dermal papilla cells in vitro. Methods: Nine healthy men received 4 minutes of standardized scalp massage per day for 24 weeks using a scalp massage device. Total hair number, hair thickness, and hair growth rate were evaluated. The mechanical effect of scalp massage on subcutaneous tissue was analyzed using a finite element method. To evaluate the effect of mechanical forces, human dermal papilla cells were cultured using a 72-hour stretching cycle. Gene expression change was analyzed using DNA microarray analyses. In addition, expression of hair cycle-related genes including IL6, NOGGIN, BMP4, and SMAD4 were evaluated using real-time reverse transcription-polymerase chain reaction. Results: Standardized scalp massage resulted in increased hair thickness 24 weeks after initiation of massage (0.085 ± 0.003 mm vs 0.092 ± 0.001 mm). Finite element method showed that scalp massage caused z-direction displacement and von Mises stress on subcutaneous tissue. In vitro, DNA microarray showed gene expression change significantly compared with nonstretching human dermal papilla cells. A total of 2655 genes were upregulated and 2823 genes were downregulated. Real-time reverse transcription-polymerase chain reaction demonstrated increased expression of hair cycle–related genes such as NOGGIN, BMP4, SMAD4, and IL6ST and decrease in hair loss–related genes such as IL6. Conclusions: Stretching forces result in changes in gene expression in human dermal papilla cells. Standardized scalp massage is a way to transmit mechanical stress to human dermal papilla cells in subcutaneous tissue. Hair thickness was shown to increase with standardized scalp massage. PMID:26904154

  14. Comparative study of the fluorescence intensity of dental composites and human teeth submitted to artificial aging.

    PubMed

    Jablonski, Tatiana; Takahashi, Marcos Kenzo; Brum, Rafeal Torres; Rached, Rodrigo Nunes; Souza, Evelise M

    2014-01-01

    The aim of this study was to evaluate quantitatively the fluorescence of resin composites and human teeth, and to determine the stability of fluorescence after aging. Ten specimens were built using a 1 mm thick increment of dentin composite overlapped by a 0.5 mm thick increment of enamel composite. Ten sound human molars were sectioned and silicon carbide-polished to obtain enamel and dentin slabs 1.5 mm in thickness. Fluorescence measurements were carried out by a fluorescence spectrophotometer before and after thermocycling (2000 cycles, 5°C and 55°C). One-way analysis of variance (ANOVA) with repeated measures and Tukey's test were performed at a significance level of 5%. Most of the tested composites showed significant differences in fluorescence both before and after aging (P < 0.05). Opallis was the only composite whose fluorescence was similar to that of human teeth at both periods of evaluation (P > 0.05), and was the only composite that showed comparable results of fluorescence to the tooth structure before and after thermocycling. With the exception of Filtek Supreme, there were significant reductions in fluorescence intensity for all the tested composites (P < 0.05).

  15. Preventable wheelchair-related thermal injury.

    PubMed

    Bull, William; Priebe, Michael; Dillig, Gina; Dado, Diane

    2006-01-01

    Wheelchair-related injuries are common, and with proper reporting of injuries, advanced technologic support may offer new ways to prevent those injuries. Case REPORT AND FINDINGS: A man with tetraplegia who retains only minimal use of his right hand experienced a right-sided armrest malfunction of his wheelchair resulting in his wheelchair controls being out of reach. This left him stranded in the sun for almost 2 hours in 86 degrees F weather. During that time, he developed full thickness sunburns of his left forearm and deep partial thickness burns of the left fingertips where they were in contact with the left armrest. This patient's full thickness burns could have been prevented if his motorized wheelchair had back-up communication in the event of a malfunction. Technology developers must realize the need for such systems. Health care professionals must advocate for a higher standard of safety and report injuries related to wheelchair malfunction.

  16. A cutaneous full-thickness liquid sulfur mustard burn model in weanling swine: clinical pathology and urinary excretion of thiodiglycol.

    PubMed

    Graham, J S; Reid, F M; Smith, J R; Stotts, R R; Tucker, E S; Shumaker, S M; Niemuth, N A; Janny, S J

    2000-12-01

    Sulfur mustard (bis(2-chloroethyl)sulfide, HD) is a well-known blistering chemical warfare agent. We have developed a cutaneous full-thickness HD burn model in weanling pigs for efficacy testing of candidate treatment regimens. This report addresses clinical pathology findings and the urinary excretion profile of a major HD metabolite (thiodiglycol, TDG) in this model. Six female Yorkshire pigs were exposed to HD liquid on the ventral surface for 2 h, generating six 3-cm diameter full-thickness dermal lesions per pig. Blood samples were collected throughout a 7-day observation period for hematology and serum chemistry examinations. Urine was collected in metabolism cages. Routine urinalysis was performed and the urine analyzed for TDG using gas chromatography/mass spectrometry. Examination of clinical pathology parameters revealed subtle HD-related changes that are suggestive of a mild hemolytic episode. No other signs of clinically significant systemic toxicities were noted, including bone marrow suppression. Thiodiglycol was detected at the earliest time point tested (6-8 h post-exposure) at levels ranging from 0.66 to 4.98 microg ml(-1) with a mean of 2.14 microg ml(-1). Thiodiglycol concentrations were the highest for half of the animals at this earliest time point and at 24-48 h for the others. By the evening of day 3, the mean level had reached 50 ng ml(-1). Mean levels remained 10-40 ng ml(-1) for the remainder of the 7-day observation period, with the highest individual concentration noted during this period of 132 ng ml(-1). Our results are in general agreement with the TDG excretion profiles previously described for rodent models and humans. Urinary excretion of absorbed HD in our weanling pig wound healing model appears to follow the same pattern as is seen in other laboratory animals models. In general, urinary excretion of TDG appears to peak within the first 1-4 days following exposure, with detectable levels after 1 week. Relatively high urinary TDG levels may thus indicate agent exposure within the previous 96 h. Low levels significantly above natural background levels may indicate either exposure to low levels of agent or exposure that occurred more than 4 days prior to collection of the sample.

  17. Resurfacing the Penis of Complex Hypospadias Repair ("Hypospadias Cripples").

    PubMed

    Fam, Mina M; Hanna, Moneer K

    2017-03-01

    After the creation of a neourethra in a "hypospadias cripple," resurfacing the penis with healthy skin is a significant challenge because local tissue is often scarred and unusable. We reviewed our experience with various strategies to resurface the penis of hypospadias cripples. We retrospectively reviewed the records of 215 patients referred after multiple unsuccessful hypospadias repairs from 1981 to 2014. In 130 of 215 patients we performed resurfacing using local penile flaps using various techniques, including Byars flaps, Z-plasty or double Z-plasty, or a dorsal relaxing incision. Of the 215 patients 85 did not have adequate healthy local penile skin to resurface the penis after urethroplasty. Scrotal skin was used to resurface the penis in 54 patients, 6 underwent tissue expansion of the dorsal penile skin during a 12 to 16-week period prior to penile resurfacing, 23 underwent full-thickness skin grafting and another 4 received a split-thickness skin graft. Of the 56 patients who underwent fasciomyocutaneous rotational flaps, tissue expansion or a combination of both approaches 54 (96.4%) finally had a successful outcome. All 6 patients who underwent tissue expansion had a successful outcome without complications and were reported on previously. All 23 full-thickness skin grafts took with excellent results. All 4 patients who underwent fenestrated split-thickness skin grafting had 100% graft take but secondary contraction and ulceration were associated with sexual activity. In our experience scrotal skin flaps, tissue expansion of the dorsal penile skin and full-thickness skin grafts serve as reliable approaches in resurfacing the penis in almost any hypospadias cripple lacking healthy local skin. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Tactile Responses to Vibration

    NASA Astrophysics Data System (ADS)

    Verrillo, Ronald T.; Bolanowski, Stanley J.

    The skin is by far the largest organ of the human body having an area of approximately 1.85 m2 in the adult male and 1.65 m2 in the adult female with an average weight of about 9 lb., comprising about 6% of the total body weight. In thickness it ranges from an average of 4.4 mm in non-hairy skin to 2.1 mm in hairy skin. It is thin over the eyelids and thick at the soles of the feet. The human body contains four types of skin.

  19. Knotless single-row rotator cuff repair: a comparative biomechanical study of 2 knotless suture anchors.

    PubMed

    Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric

    2013-08-01

    The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.

  20. Clinical Comparison of Full and Partial Double Pedicle Flaps with Connective Tissue Grafts for Treatment of Gingival Recession

    PubMed Central

    Ranjbari, Ardeshir; Gholami, Gholam Ali; Amid, Reza; Kadkhodazadeh, Mahdi; Youssefi, Navid; Mehdizadeh, Amir Reza; Aghaloo, Maryam

    2016-01-01

    Statement of the Problem Gingival recession has been considered as the most challenging issue in the field of periodontal plastic surgery. Purpose The purpose of this study was to evaluate the clinical efficacy of root coverage procedures by using partial thickness double pedicle graft and compare it with full thickness double pedicle graft. Materials and Method Eight patients, aged 15 to 58 years including 6 females and 2 males with 20 paired (mirror image) defects with class I and II gingival recession were randomly assigned into two groups. Clinical parameters such as recession depth, recession width, clinical attachment level, probing depth, and width of keratinized tissue were measured at the baseline and 6 months post-surgery. A mucosal double papillary flap was elevated and the respective root was thoroughly planed. The connective tissue graft was harvested from the palate, and then adapted over the root. The pedicle flap was secured over the connective tissue graft and sutured. The surgical technique was similar in the control group except for the prepared double pedicle graft which was full thickness. Results The mean root coverage was 88.14% (2.83 mm) in the test group and 85.7% (2.75 mm) in the control group. No statistical differences were found in the mean reduction of vertical recession, width of recession, or probing depth between the test and control groups. In both procedures, the width of keratinized tissue increased after three months and the difference between the two groups was not statistically significant in this respect. Conclusion Connective tissue with partial and full thickness double pedicle grafts can be successfully used for treatment of marginal gingival recession. PMID:27602394

  1. The effects of different doses of IGF-1 on cartilage and subchondral bone during the repair of full-thickness articular cartilage defects in rabbits.

    PubMed

    Zhang, Z; Li, L; Yang, W; Cao, Y; Shi, Y; Li, X; Zhang, Q

    2017-02-01

    To investigate the effects of different doses of insulin-like growth factor 1 (IGF-1) on the cartilage layer and subchondral bone (SB) during repair of full-thickness articular cartilage (AC) defects. IGF-1-loaded collagen membrane was implanted into full-thickness AC defects in rabbits. The effects of two different doses of IGF-1 on cartilage layer and SB adjacent to the defect, the cartilage structure, formation and integration, and the new SB formation were evaluated at the 1st, 4th and 8th week postoperation. Meanwhile, after 1 week treatment, the relative mRNA expressions in tissues adjacent to the defect, including cartilage and SB were determined by quantitative real-time RT-PCR (qRT-PCR), respectively. Different doses of IGF-1 induced different gene expression profiles in tissues adjacent to the defect and resulted in different repair outcomes. Particularly, at high dose IGF-1 aided cell survival, regulated the gene expressions in cartilage layer adjacent defect and altered ECM composition more effectively, improved the formation and integrity of neo-cartilage. While, at low dose IGF-1 regulated the gene expressions in SB more efficaciously and subsequently promoted the SB remodeling and reconstruction. Different doses of IGF-1 induced different responses of cartilage or SB during the repair of full-thickness AC defects. Particularly, high dose of IGF-1 was more beneficial to the neo-cartilage formation and integration, while low dose of it was more effective for the SB formation. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  2. Transplantation of an LGR6+ Epithelial Stem Cell-Enriched Scaffold for Repair of Full-Thickness Soft-Tissue Defects: The In Vitro Development of Polarized Hair-Bearing Skin.

    PubMed

    Lough, Denver M; Wetter, Nathan; Madsen, Christopher; Reichensperger, Joel; Cosenza, Nicole; Cox, Lisa; Harrison, Carrie; Neumeister, Michael W

    2016-02-01

    Recent literature has shown that full-thickness wounds, devoid of the stem cell niche, can subsequently be reconstructed with functional skin elements following migration of the LGR6 epithelial stem cell into the wound bed. In this study, the authors use a variety of LGR6 epithelial stem cell-seeded scaffolds to determine therapeutic utility and regenerative potential in the immediate reconstruction of full-thickness wounds. Isolated LGR6 epithelial stem cells were seeded onto a spectrum of acellular matrices and monitored in both in vitro and in vivo settings to determine their relative capacity to regenerate tissues and heal wounds. Wound beds containing LGR6 stem cell-seeded scaffolds showed significantly augmented rates of healing, epithelialization, and hair growth compared with controls. Gene and proteomic expression studies indicate that LGR6 stem cell-seeded constructs up-regulate WNT, epidermal growth factor, and angiogenesis pathways. Finally, the addition of stromal vascular fraction to LGR6 stem cell-seeded constructs induces polarized tissue formation, nascent hair growth, and angiogenesis within wounds. LGR6 stem cells are able to undergo proliferation, differentiation, and migration following seeding onto a variety of collagen-based scaffolding. In addition, deployment of these constructs induces epithelialization, hair growth, and angiogenesis within wound beds. The addition of stromal vascular fraction to LGR6 stem cell-containing scaffolds initiated an early form of tissue polarization, providing for the first time a clinically applicable stem cell-based construct that is capable of the repair of full-thickness wounds and hair regeneration. Therapeutic, V.

  3. Effectiveness of Physical Therapy in Treating Atraumatic Full Thickness Rotator Cuff Tears. A Multicenter Prospective Cohort Study

    PubMed Central

    Kuhn, John E.; Dunn, Warren R.; Sanders, Rosemary; An, Qi; Baumgarten, Keith M.; Bishop, Julie Y.; Brophy, Robert H.; Carey, James L.; Holloway, Brian G.; Jones, Grant L.; Ma, C. Benjamin; Marx, Robert G.; McCarty, Eric C.; Poddar, Sourav K.; Smith, Matthew V.; Spencer, Edwin E.; Vidal, Armando F.; Wolf, Brian R.; Wright, Rick W.

    2013-01-01

    Purpose To assess the effectiveness of a specific non-operative physical therapy program in treating atraumatic full thickness rotator cuff tears using a multicenter prospective cohort study design. Methods Patients with atraumatic full thickness rotator cuff tears who consented to enroll provided data via questionnaire on demographics, symptom characteristics, co-morbidities, willingness to undergo surgery, and patient related outcome assessments (SF-12, ASES, WORC, SANE score, Shoulder Activity Scale). Physicians recorded physical examination and imaging data. Patients began a physical therapy program developed from a systematic review of the literature and returned for evaluation at 6 and 12 weeks. At those visits patients could chose one of three courses: 1.) Cured (no formal follow up scheduled), 2.) Improved (continue therapy with scheduled reassessment in 6 weeks), or 3.) No better (offered surgery). Patients were contacted by telephone at 1 and 2 years to determine if they had undergone surgery since their last visit. A Wilcoxon signed rank test with continuity correction was used to compare initial, 6 week, and 12 week outcome scores. Results The cohort consists of 452 patients. Patient reported outcomes improved significantly at 6 and 12 weeks. Patients elected to undergo surgery less than 25% of the time. Patients who decided to have surgery generally did so between 6 and 12 weeks, and few had surgery between 3 and 24 months. Conclusion Non-operative treatment using this physical therapy protocol is effective for treating atraumatic full thickness rotator cuff tears in approximately 75% of patients followed for two years. Level of evidence Level IV, Case Series, Treatment Study PMID:23540577

  4. Effect of sildenafil citrate on secondary healing in full thickness skin defects in experiment.

    PubMed

    Cakmak, E; Karasoy Yesilada, A; Sevim, K Z; Sumer, O; Tatlidede, H S; Sakiz, D

    2014-01-01

    An acceleration of the wound healing process expedites chronic wound patient's return to normal social environments significantly. Sildenafil, a cyclic guanosine monophosphate (cGMP)-dependent phosphodiesterase- 5 inhibitor has been shown to be a potent stimulator of angiogenesis through upregulation of cGMP. In our study, sildenafil was administered orally as a cost-effective supplement in the treatment of full thickness defects and chronic wounds in that manner with low incidence of side effects and morbidity. Randomly selected 72 Wistar-Albino rats were divided into the two groups, 36 rats in each group. Control group (n =36) was divided further into a secondary healing group consisting of 9 rats and a pathology group consisting of 27 rats (pathology group 1: 9 rats, 4th and 7th day of wound healing, pathology group 2: 9 rats, 10th and 14th day of wound healing, pathology group 3: 9 rats, 21st and 28th day of wound healing. Experimental group consisted of 36 rats which received sildenafil citrate (Viagra® Pfizer, Germany) for secondary wound healing to proceed. The average wound healing period in the control group was 17.89 days and in the sildenafil citrate administered group 14.56 days. The difference of the epithelialisation on full thickness defects were more prominent on days 5 and 11 postoperatively. In the sildenafil citrate applied group, on the 7th day, the defect was 25% smaller and on the 13th day, the defect contracted by 38%. In conclusion, we believe that sildenafil citrate administered orally is a cost- effective supplement in the treatment of full thickness defects and chronic wounds in that manner with low incidence of side effects and morbidity (Tab. 4, Fig. 7, Ref. 34).

  5. [Wound healing is still a game of " blind men and an elephant"].

    PubMed

    Han, C M

    2016-10-20

    The wound healing includes non-healing and overhealing of the wounds. The results of wound healing are well known by people such as non-healing of the diabetic ulcer or hypertrophic scar after deep burn. In this issue, three papers involve in wound healing, one about autologous adipose-derived mesenchymal stem cells injected into wound or scar of rabbit ear, one about severe hypoxia and hypoalbuminemia inducing human hypertrophic scar derived fibroblast apoptosis in vitro, and another about the dysfunction of protein kinase B/mammalian target of rapamycin signaling pathway contributing to the pathophysiological characteristics of diabetic skin and non-healing wound. The basic problem of hypertrophic scar study is lacking an ideal animal model. Although rabbit ear model or red Duroc pig model has been used widely for study on hypertrophic scar, they can not fully represent human dermal fibrosis after deep trauma on the skin. I recommend A novel nude mouse model of hypertrophic scarring using scratched full thickness human skin grafts recently published in Advances in Wound Care to the readers. The author emphasizes that the wound healing study is still in the situation like the game of " blind men and an elephant" .

  6. Microvesicating effects of sulfur mustard on an in vitro human skin model.

    PubMed

    Hayden, Patrick J; Petrali, John P; Stolper, Gina; Hamilton, Tracey A; Jackson, George R; Wertz, Philip W; Ito, Susumu; Smith, William J; Klausner, Mitchell

    2009-10-01

    Bis-(beta-chloroethyl) sulfide (SM) is a potent skin vesicant previously used for chemical warfare. Progress in determination of the mechanistic basis of SM pathology, and development of prophylactic and/or therapeutic countermeasures to SM exposure has been hampered by lack of physiologically relevant models of human skin. The current work evaluated a newly developed tissue engineered full-thickness human skin model in a completely in vitro approach to investigation of SM-induced dermal pathology. The model was first characterized with regard to overall morphology, lipid composition, basement membrane (BM) composition and ultrastructural features that are important targets of SM pathologic activity. Well-developed BM ultrastructural features were observed at the dermal-epidermal junction (DEJ), thus demonstrating successful resolution of a primary deficiency of models previously evaluated for SM studies. Studies were then conducted to evaluate histopathological effects of SM on the model. Good replication of in vivo effects was observed, including apoptosis of basal keratinocytes (KC) and microblister formation at the DEJ. Tissue engineered skin models with well-developed basement membrane structures thus appear to be useful tools for in vitro mechanistic studies of SM vesicant activity and development of preventive/therapeutic approaches for SM pathology.

  7. Metabolically Competent Human Skin Models: Activation and Genotoxicity of Benzo[a]pyrene

    PubMed Central

    Henkler, Frank

    2013-01-01

    The polycyclic aromatic hydrocarbon (PAH) benzo[a]pyrene (BP) is metabolized into a complex pattern of BP derivatives, among which the ultimate carcinogen (+)-anti-BP-7,8-diol-9,10-epoxide (BPDE) is formed to certain extents. Skin is frequently in contact with PAHs and data on the metabolic capacity of skin tissue toward these compounds are inconclusive. We compared BP metabolism in excised human skin, commercially available in vitro 3D skin models and primary 2D skin cell cultures, and analyzed the metabolically catalyzed occurrence of seven different BP follow-up products by means of liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). All models investigated were competent to metabolize BP, and the metabolic profiles generated by ex vivo human skin and skin models were remarkably similar. Furthermore, the genotoxicity of BP and its derivatives was monitored in these models via comet assays. In a full-thickness skin, equivalent BP-mediated genotoxic stress was generated via keratinocytes. Cultured primary keratinocytes revealed a level of genotoxicity comparable with that of direct exposure to 50–100nM of BPDE. Our data demonstrate that the metabolic capacity of human skin ex vivo, as well as organotypic human 3D skin models toward BP, is sufficient to cause significant genotoxic stress and thus cutaneous bioactivation may potentially contribute to mutations that ultimately lead to skin cancer. PMID:23148024

  8. Local and systemic effects of leg cycling training on arterial wall thickness in healthy humans.

    PubMed

    Thijssen, Dick H J; Dawson, Ellen A; van den Munckhof, Inge C L; Birk, Gurpreet K; Timothy Cable, N; Green, Daniel J

    2013-08-01

    Exercise training is associated with direct effects on conduit artery function and structure. Cross-sectional studies suggest the presence of systemic changes in wall thickness as a result of exercise in healthy subjects, but no previous study has examined this question in humans undertaking exercise training. To examine the change in superficial femoral (SFA, i.e. local effect) and carotid (CA, i.e. systemic effect) artery wall thickness across 8 weeks of lower limb cycle training in healthy young men. Fourteen healthy young male subjects were assigned to an 8-week training study of cycling exercise (n = 9) or a control period (n = 5). Before, during (2, 4 and 6 weeks) and after training, SFA and CA wall thickness was examined using automated edge-detection of high resolution ultrasound images. We also measured resting diameter and calculated the wall:lumen(W:L)-ratio. Exercise training did not alter CA or SFA baseline diameter (P = 0.14), but was associated with gradual, consistent and significant decreases in wall thickness and W:L-ratio in both the CA and SFA (P < 0.001 and 0.002, respectively). Two-way ANOVA revealed a comparable magnitude of decrease in wall thickness and W:L-ratio in both arteries across the 8-week period (interaction-effect; P = 0.29 and 0.12, respectively). No changes in artery diameter, wall thickness or W:L-ratio were apparent in controls (0.82, 0.38 and 0.52, respectively). We found that cycle exercise training in healthy young individuals is associated with modest, but significant, decreases in wall thickness in the superficial femoral and carotid arteries. These findings suggest that exercise training causes systemic adaptation of the arterial wall in healthy young subjects. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Wound Healing from Dermal Grafts Containing CD34+ Cells Is Comparable to Wound Healing with Split-Thickness Skin Micrografts.

    PubMed

    Nuutila, Kristo; Singh, Mansher; Kruse, Carla; Eriksson, Elof

    2017-08-01

    Epidermal stem cells present in the skin appendages of the dermis might be crucial in wound healing. In this study, the authors located these cells in the dermis and evaluated their contribution to full-thickness wound healing in a porcine model. Four sequentially deeper 0.35-mm-thick skin grafts were harvested from the same donor site going down to 1.4 mm in depth (layers 1 through 4). The layers were minced to 0.8 × 0.8 × 0.35-mm micrografts and transplanted (1:2) onto full-thickness porcine wounds. Healing was monitored up to 28 days and biopsy specimens were collected on days 6 and 10. Multiple wound healing parameters were used to assess the quality of healing. The authors' results showed that wounds transplanted with layer 2 (0.35 to 0.7 mm) and layer 3 (0.7 to 1.05 mm) micrografts demonstrated reepithelialization rates comparable to that of split-thickness skin graft (layer 1, 0.00 to 0.35 mm; split-thickness skin graft) at day 10. At day 28, dermal micrografts (layers 2 and 3) showed quality of healing comparable to that of split-thickness skin grafts (layer 1) in terms of wound contraction and scar elevation index. The amounts of epidermal stem cells [cluster of differentiation (CD) 34] and basal keratinocytes (KRT14) at each layer were quantified by immunohistochemistry. The analysis showed that layers 2 and 3 contained the most CD34 cells and layer 1 was the richest in KRT14 cells. The immunohistochemistry also indicated that, by day 6, CD34 cells had differentiated into KRT14 cells, which migrated from the grafts and contributed to the reepithelialization of the wound.

  10. Modeling recent human evolution in mice by expression of a selected EDAR variant

    PubMed Central

    Kamberov, Yana G.; Wang, Sijia; Tan, Jingze; Gerbault, Pascale; Wark, Abigail; Tan, Longzhi; Yang, Yajun; Li, Shilin; Tang, Kun; Chen, Hua; Powell, Adam; Itan, Yuval; Fuller, Dorian; Lohmueller, Jason; Mao, Junhao; Schachar, Asa; Paymer, Madeline; Hostetter, Elizabeth; Byrne, Elizabeth; Burnett, Melissa; McMahon, Andrew P.; Thomas, Mark G.; Lieberman, Daniel E.; Jin, Li; Tabin, Clifford J.; Morgan, Bruce A.; Sabeti, Pardis C.

    2013-01-01

    Summary An adaptive variant of the human Ectodysplasin receptor, EDARV370A, is one of the strongest candidates of recent positive selection from genome-wide scans. We have modeled EDAR370A in mice and characterized its phenotype and evolutionary origins in humans. Our computational analysis suggests the allele arose in Central China approximately 30,000 years ago. Although EDAR370A has been associated with increased scalp hair thickness and changed tooth morphology in humans, its direct biological significance and potential adaptive role remain unclear. We generated a knock-in mouse model and find that, as in humans, hair thickness is increased in EDAR370A mice. We identify novel biological targets affected by the mutation, including mammary and eccrine glands. Building on these results, we find that EDAR370A is associated with an increased number of active eccrine glands in the Han Chinese. This interdisciplinary approach yields unique insight into the generation of adaptive variation among modern humans. PMID:23415220

  11. In-Place Recycling and Reclamation of Asphaltic Concrete Pavements in Kentucky

    DOT National Transportation Integrated Search

    2017-11-01

    Full-depth reclamation has been defined by the Asphalt Recycling and Reclaiming Association as a rehabilitation technique in which the full thickness of the asphalt pavement and a predetermined portion of the underlying material (base, subbase, an...

  12. The differentiation profile of the epithelium of the human lip.

    PubMed

    Barrett, A W; Morgan, M; Nwaeze, G; Kramer, G; Berkovitz, B K B

    2005-04-01

    The aim of this study was to analyse the immunohistochemical differentiation profile of the stratified squamous epithelium of the adult human lip. Full-thickness lower lips taken from 31 cadavers were analysed. Sections were stained with haematoxylin and eosin, periodic acid-Schiff (PAS), cytokeratins (CK), loricrin, involucrin, profilaggrin and filaggrin. The stratified squamous epithelium covering the lip could be divided into: (i) appendage-bearing, orthokeratinised epidermis; (ii) orthokeratinised vermilion which had a more prominent rete pattern than the epidermis; (iii) parakeratinised, PAS-positive intermediate zone; and (iv) non- or parakeratinised labial mucosal epithelium. Epithelial thickness increased gradually from the skin to the mucosal aspect. The CK pattern changed across the intermediate zone, with gradual loss of CK 1 and 10 from the skin, and CK 4, 13 and 19 from the mucosal, aspect. CK 5 and 14 were consistently expressed basally, and variably expressed suprabasally. Apart from labelling Merkel cells, CK 8, 18 and 20 were negative. Involucrin, which was present at all sites, was restricted to the stratum granulosum in skin, but extended into the stratum spinosum, and gradually into parabasal keratinocytes, across the vermilion and mucosa. Loricrin, profilaggrin and filaggrin were present in the stratum granulosum of orthokeratinised sites, but expression was abruptly lost at the junction between the vermilion and the intermediate zone. In conclusion, the phenotype of the stratified squamous epithelium covering the lip changes at, or across, the intermediate zone of the adult vermilion. It is possible that changes in the composition of the stratified squamous epithelium affect the colour of the vermilion.

  13. Estrogen receptor alpha localization in the testes of men with normal spermatogenesis.

    PubMed

    Filipiak, Eliza; Suliborska, Dagmara; Laszczynska, Maria; Walczak-Jedrzejowska, Renata; Oszukowska, Elzbieta; Marchlewska, Katarzyna; Kula, Krzysztof; Slowikowska-Hilczer, Jolanta

    2013-10-08

    It is known that estrogens act on the male reproductive tract by binding to estrogen receptors (ER) α and β. However, studies on ER localization in the human testis are discordant. The aim of this study was to investigate the localization of ERα in the testes of adult men with normal spermatogenesis. Semen analysis of ten adult men revealed azoospermia. FSH, LH and testosterone serum concentrations were within normal values, and the volume of the testes was normal, hence obstructive azoospermia was suspected. The tissues from testicular surgical biopsies were fixed in Bouin's fluid and embedded in paraffin. Assessments of the seminiferous epithelium (scoring 10 to -1), the number of Leydig cells (scoring 1 to 5), the areal fraction of intertubular space (IS), measurements of seminiferous tubule diameter, and the thickness of the tubular wall, were performed on microscopic sections. Immunohistochemical staining was applied with monoclonal antibodies against ERα. The mean spermatogenesis score was 10 points; IS - 30.6 ± 8.1%; seminiferous tubule diameter - 193.9 ± 19.4 μm; thickness of tubular wall - 7.44 ± 1.1 μm; number of Leydig cells - 1.6 ± 1.1 points. Immunohistochemical staining showed the localization of ERα to be in the Sertoli and Leydig cell cytoplasm, while ERα was absent in germ cells. The results of testicular tissue analysis confirmed its normal structure and normal, full spermatogenesis. The presence of ERα in Sertoli and Leydig cells in normal human testis demonstrated in this study suggests that estrogens may affect testicular function.

  14. Fabrication of multi-focal microlens array on curved surface for wide-angle camera module

    NASA Astrophysics Data System (ADS)

    Pan, Jun-Gu; Su, Guo-Dung J.

    2017-08-01

    In this paper, we present a wide-angle and compact camera module that consists of microlens array with different focal lengths on curved surface. The design integrates the principle of an insect's compound eye and the human eye. It contains a curved hexagonal microlens array and a spherical lens. Compared with normal mobile phone cameras which usually need no less than four lenses, but our proposed system only uses one lens. Furthermore, the thickness of our proposed system is only 2.08 mm and diagonal full field of view is about 100 degrees. In order to make the critical microlens array, we used the inkjet printing to control the surface shape of each microlens for achieving different focal lengths and use replication method to form curved hexagonal microlens array.

  15. Evaluation of endothelial mucin layer thickness after phacoemulsification with next generation ophthalmic irrigating solution.

    PubMed

    Ghate, Deepta A; Holley, Glenn; Dollinger, Harli; Bullock, Joseph P; Markwardt, Kerry; Edelhauser, Henry F

    2008-10-01

    To evaluate human corneal endothelial mucin layer thickness and ultrastructure after phacoemulsification and irrigation-aspiration with either next generation ophthalmic irrigating solution (NGOIS) or BSS PLUS. Paired human corneas were mounted in an artificial anterior chamber, exposed to 3 minutes of continuous ultrasound (US) at 80% power using the Alcon SERIES 20000 LEGACY surgical system (n = 9) or to 2 minutes of pulsed US at 50% power, 50% of the time at 20 pps using the Alcon INFINITI Vision System (n = 5), and irrigated with 250 mL of either NGOIS or BSS PLUS. A control group of paired corneas did not undergo phacoemulsification or irrigation-aspiration (n = 5). Corneas were divided and fixed for mucin staining or transmission electron microscopy. Mucin layer thickness was measured on the transmission electron microscopy prints. The mucin layer thickness in the continuous phaco group was 0.77 +/- 0.02 microm (mean +/- SE) with NGOIS and 0.51 +/- 0.01 microm with BSS PLUS (t test, P < 0.001). The mucin layer thickness in the pulsed phaco group was 0.79 +/- 0.02 microm with NGOIS and 0.54 +/- 0.01 microm with BSS PLUS (P < 0.001). The mucin layer thickness in the untreated control group was 0.72 +/- 0.02 microm. The endothelial ultrastructure was normal in all corneas. In this in vitro corneal model, NGOIS, due to its lower surface tension and higher viscosity, preserved endothelial mucin layer thickness better than BSS PLUS with both the INFINITI Vision System (pulsed US) and the LEGACY surgical system (continuous US).

  16. Acute and chronic response of articular cartilage to Ho:YAG laser irradiation

    NASA Astrophysics Data System (ADS)

    Trauner, Kenneth B.; Nishioka, Norman S.; Flotte, Thomas J.; Patel, Dinesh K.

    1992-06-01

    A Ho:YAG laser system operating at a wavelength of 2.1 microns has recently been introduced for use in arthroscopic surgery. The acceptability of this new tool will be determined not only by its ability to resect tissue, but also by its long term effects on articular surfaces. In order to investigate these issues further, we performed two studies to evaluate the acute and chronic effects of the laser on cartilaginous tissue. We evaluated the acute, in vitro effects of 2.1 micron laser irradiation on articular and fibrocartilage. This included the measurement of ablation efficiency, ablation threshold and thermal damage in both meniscus and articular cartilage. To document the chronic effects on articular cartilage in vivo, we next performed a ten week healing study. Eight sheep weighing 30 - 40 kg underwent bilateral arthrotomy procedures. Multiple full thickness and partial thickness defects were created. Animals were sacrificed at 0, 2, 4, and 10 weeks. The healing study demonstrated: (1) no healing of full or partial thickness defects at 10 weeks with hyaline cartilage; (2) fibrocartilaginous granulation tissue filling full thickness defects at two and four weeks, but no longer evident at ten weeks; (3) chondrocyte necrosis extending to greater than 900 microns distal to ablation craters at four weeks with no evidence of repair at later dates; and (4) chondrocyte hyperplasia at the borders of the damage zone at two weeks but no longer evident at later sacrifice dates.

  17. Association between retinal nerve fiber layer thickness and magnetic resonance imaging findings and intelligence in patients with multiple sclerosis.

    PubMed

    Ashtari, Fereshteh; Emami, Parisa; Akbari, Mojtaba

    2015-01-01

    Multiple Sclerosis (MS) is a neurological disease in which demyelination and axonal loss leads to progressive disability. Cognition impairment is among the most common complication. Studying axonal loss in the retina is a new marker for MS. The main goal of our study is to search for correlations between magnetic resonance imaging (MRI) findings and the retinal nerve fiber layer (RNFL) thickness at the macula and head of the optic nerve and Wechsler Adult Intelligence Scale-Revised (WAIS-R) Scores that assess multiple domains of intelligence, and to explore the relationship between changes in the RNFL thickness with intellectual and cognitive dysfunction. A prospective cross-sectional study was conducted at the University Hospital of Kashani, Isfahan, Iran, from September to December 2013. All patients were assessed with a full-scale intelligence quotient (IQ) on the WAIS-R. An optical coherence tomography study and brain MRI were performed in the same week for all the patients. Statistical analysis was conducted by using a bivariate correlation, by utilizing SPSS 20.0. A P value ≤ 0.05 was the threshold of statistical significance. Examination of a 100 patients showed a significant correlation between the average RNFL thickness of the macula and the verbal IQ (P value = 0.01) and full IQ (P value = 0.01). There was a significant correlation between brain atrophy and verbal IQ. The RNFL loss was correlated with verbal IQ and full IQ.

  18. Induction of Skin-Derived Precursor Cells from Human Induced Pluripotent Stem Cells.

    PubMed

    Sugiyama-Nakagiri, Yoriko; Fujimura, Tsutomu; Moriwaki, Shigeru

    2016-01-01

    The generation of full thickness human skin from dissociated cells is an attractive approach not only for treating skin diseases, but also for treating many systemic disorders. However, it is currently not possible to obtain an unlimited number of skin dermal cells. The goal of this study was to develop a procedure to produce skin dermal stem cells from induced pluripotent stem cells (iPSCs). Skin-derived precursor cells (SKPs) were isolated as adult dermal precursors that could differentiate into both neural and mesodermal progenies and could reconstitute the dermis. Thus, we attempted to generate SKPs from iPSCs that could reconstitute the skin dermis. Human iPSCs were initially cultured with recombinant noggin and SB431542, an inhibitor of activin/nodal and TGFβ signaling, to induce neural crest progenitor cells. Those cells were then treated with SKP medium that included CHIR99021, a WNT signal activator. The induction efficacy from neural crest progenitor cells to SKPs was more than 97%. No other modifiers tested were able to induce those cells. Those human iPSC-derived SKPs (hiPSC-SKPs) showed a similar gene expression signature to SKPs isolated from human skin dermis. Human iPSC-SKPs differentiated into neural and mesodermal progenies, including adipocytes, skeletogenic cell types and Schwann cells. Moreover, they could be induced to follicular type keratinization when co-cultured with human epidermal keratinocytes. We here provide a new efficient protocol to create human skin dermal stem cells from hiPSCs that could contribute to the treatment of various skin disorders.

  19. [Treatment of acute full-thickness chondral defects with high molecular weight hyaluronic acid; an experimental model].

    PubMed

    Figueroa, D; Espinosa, M; Calvo, R; Scheu, M; Valderrama, J J; Gallegos, M; Conget, P

    2014-01-01

    To evaluate the effect of 2 different protocols of intra-articular hyaluronic acid (HA, hylan G-F20) to articular cartilage regeneration in acute full-thickness chondral defects. Full-thickness chondral defects of 3 x 6 mm were performed into the lateral femoral condyles of New Zealand rabbits, treated with a single or three doses of HA. The animals were sacrified at 12 weeks and the regenerated tissue was evaluated by direct observation and histology with the ICRS scale. Macroscopically, in both groups treated with HA the defects were filled with irregular tissue with areas similar to hyaline cartilage and others in which depressed areas with exposed subchondral bone were observed. Histological analysis showed in both groups treated with HA a hyaline-like cartilage compared to control group. However, the score of the International Cartilage Repair Society (ICRS) scale did not show differences between the groups treated with HA. The use of single dose or 3 doses of AH in acute chondral lesions has a limited and similar benefit in articular cartilage regeneration. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Full-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism.

    PubMed

    Kim, Bu Ki; Mun, Su Joung; Lee, Dae Gyu; Kim, Jae Ryun; Kim, Hyun Seung; Chung, Young Taek

    2015-12-01

    To explore the clinical effects of combined full-thickness astigmatic keratotomy and small-incision lenticule extraction (SMILE) in patients who are inoperable using SMILE alone. We included 13 eyes of 9 patients with high-level or mixed astigmatism who underwent full-thickness astigmatic keratotomy followed by SMILE (secondarily) to correct the residual refractive error. Six months after SMILE, the spherical equivalent was reduced from -4.83 ± 3.26 D to -0.17 ± 0.38 D (P < 0.001), and the astigmatism was reduced from 5.12 ± 0.96 D to 0.21 ± 0.22 D (P < 0.001). The uncorrected and corrected (CDVA) distance visual acuities improved from 1.07 ± 0.62 to 0.02 ± 0.13 (P < 0.001) and from 0.08 ± 0.14 to -0.01 ± 0.14 (P = 0.002), respectively. The CDVA improved by 1 or 2 Snellen lines in 8 cases (61.5%), and there was no loss in CDVA. All procedures were completed without intraoperative or postoperative complications. This combined procedure was effective and safe for the treatment of high-level or mixed astigmatism.

  1. The Use of Fetal Bovine Dermal Scaffold (PriMatrix) in the Management of Full-Thickness Hand Burns.

    PubMed

    Parcells, Alexis Lanteri; Karcich, Jenika; Granick, Mark S; Marano, Michael A

    2014-01-01

    Management of full-thickness burn wounds represents a challenge when reconstructive options are not applicable. Fetal bovine dermal matrix is a bioactive collagen scaffold that assimilates into wounds and stimulates vascularization and dermal regeneration. We present the use of fetal bovine dermal scaffold PriMatrix in the treatment of a patient who sustained scald-immersion full-thickness burns of her bilateral hands that failed conventional wound therapy. A 71-year-old woman with advanced Parkinson's disease sustained self-induced 5% mixed second- and third-degree scald-immersion burns of her bilateral hands and fingers. The patient underwent extensive debridement that resulted in partially avascular wounds measuring 66 cm(2) and 72 cm(2) with exposed extensor tendons and no evidence of bleeding. Meshed homograft was applied, but her hands remained partly avascular. PriMatrix fetal bovine dermal scaffold was applied to provide tissue remodeling over the bones, which allowed successful skin grafting and complete wound healing. Our experience shows fetal bovine dermal scaffold to be an effective method in management of complicated burn wounds in selected cases. Further studies need to be implemented to confer this conclusion.

  2. The Use of Fetal Bovine Dermal Scaffold (PriMatrix) in the Management of Full-Thickness Hand Burns

    PubMed Central

    Karcich, Jenika; Granick, Mark S.; Marano, Michael A.

    2014-01-01

    Objective: Management of full-thickness burn wounds represents a challenge when reconstructive options are not applicable. Fetal bovine dermal matrix is a bioactive collagen scaffold that assimilates into wounds and stimulates vascularization and dermal regeneration. Methods: We present the use of fetal bovine dermal scaffold PriMatrix in the treatment of a patient who sustained scald-immersion full-thickness burns of her bilateral hands that failed conventional wound therapy. Results: A 71-year-old woman with advanced Parkinson's disease sustained self-induced 5% mixed second- and third-degree scald-immersion burns of her bilateral hands and fingers. The patient underwent extensive debridement that resulted in partially avascular wounds measuring 66 cm2 and 72 cm2 with exposed extensor tendons and no evidence of bleeding. Meshed homograft was applied, but her hands remained partly avascular. PriMatrix fetal bovine dermal scaffold was applied to provide tissue remodeling over the bones, which allowed successful skin grafting and complete wound healing. Conclusions: Our experience shows fetal bovine dermal scaffold to be an effective method in management of complicated burn wounds in selected cases. Further studies need to be implemented to confer this conclusion. PMID:25328569

  3. [Comparative study of the repair of full thickness tear of the supraspinatus by means of "single row" or "suture bridge" techniques].

    PubMed

    Arroyo-Hernández, M; Mellado-Romero, M A; Páramo-Díaz, P; Martín-López, C M; Cano-Egea, J M; Vilá Y Rico, J

    2015-01-01

    The purpose of this study is to analyze if there is any difference between the arthroscopic reparation of full-thickness supraspinatus tears with simple row technique versus suture bridge technique. We accomplished a retrospective study of 123 patients with full-thickness supraspinatus tears between January 2009 and January 2013 in our hospital. There were 60 simple row reparations, and 63 suture bridge ones. The mean age in the simple row group was 62.9, and in the suture bridge group was 63.3 years old. There were more women than men in both groups (67%). All patients were studied using the Constant test. The mean Constant test in the suture bridge group was 76.7, and in the simple row group was 72.4. We have also accomplished a statistical analysis of each Constant item. Strength was higher in the suture bridge group, with a significant statistical difference (p 0.04). The range of movement was also greater in the suture bridge group, but was not statistically significant. Suture bridge technique has better clinical results than single row reparations, but the difference is not statistically significant (p = 0.298).

  4. [Clinical study of full-thickness skin graft for reconstruction of completely defect nail unit].

    PubMed

    Li, Wen-jun; Li, Chun; Zhu, Jin; Tian, Guang-lei; Chen, Shan-lin; Tian, Wen

    2012-12-18

    To explore a reconstruction method for complete nail bed defect caused by various kinds of reasons and to retrospectively analyze the effect of application of free full-thickness skin graft for the whole nail unit repair. Between Apr. 2010 and Mar. 2012, the method of free full-thickness skin graft was done for reconstruction of the completely nail unit defect in seven cases. There were 2 male and 5 female patients; the mean age of these patients at the time of surgery was 51.9 years (range: 7 to 70 years). The preoperative diagnoses included two cases of malignant melanoma, one of chronic infection, one of squamous cell carcinoma, two of subungual pigmentation and one of junctional nevus. There were 2 thumb lesions, 3 middle and 2 index finger lesions. Nail unit defect was in the range of 1.5 cm×2 cm to 2.5 cm × 3.5 cm and full thickness skin graft was harvested from the same medial side of upper arm (3 cases), forearm cubital fossa (1 case) and contralateral side of groin region (3 cases). All the patients were followed with an average follow-up time being 10 months. All the free skin graft taken was achieved with 100% in all the 7 cases, even in those patients whose partial cortical bone had been curetted. The skin graft was often bluish initially, and superficial blisters were always noticed within 1.5 months postoperatively and the survival skin graft was smooth eventually, and skin graft was adhered to the underlying bone tightly. There was no epidermal inclusion cyst and no residual nail formation. The skin donor sites were without complications. Aesthetic appearance was assessed by the surgeons and found no unacceptable for their patients. And all the patients were satisfied with the cosmetic appearance and active range of motion of their involved fingers, who did not express a desire to undergo any further of nail reconstruction. Free full-thickness skin grafting for reconstruction of the complete nail unit defect is a simple, safe and effective procedure which provides a satisfactory aesthetic appearance and does not make any significant skin donor site morbidity especially for middle-aged and elder patients.

  5. Effect on Patient-Reported Outcomes of Debridement or Microfracture of Concomitant Full-Thickness Cartilage Lesions in Anterior Cruciate Ligament-Reconstructed Knees: A Nationwide Cohort Study From Norway and Sweden of 357 Patients With 2-Year Follow-up.

    PubMed

    Røtterud, Jan Harald; Sivertsen, Einar Andreas; Forssblad, Magnus; Engebretsen, Lars; Årøen, Asbjørn

    2016-02-01

    The treatment of concomitant cartilage lesions in anterior cruciate ligament (ACL)-injured knees is debatable. To evaluate the effect of debridement or microfracture (MF) compared with no treatment of concomitant full-thickness (International Cartilage Repair Society [ICRS] grades 3-4) cartilage lesions on patient-reported outcomes after ACL reconstruction. Cohort study; Level of evidence, 2. Six hundred forty-four patients who underwent primary unilateral ACL reconstruction and had a concomitant full-thickness cartilage lesion treated simultaneously by debridement (n = 129) or MF (n = 164), or underwent no treatment (n = 351) of the cartilage lesion, registered in the Norwegian and Swedish National Knee Ligament Registries from 2005 to 2008 were included. The Knee Injury and Osteoarthritis Outcome Score (KOOS) was used to measure patient-reported outcomes. At a mean follow-up of 2.1 ± 0.2 years after surgery, 357 (55%) patients completed the KOOS. Linear regression analyses were used to evaluate the effect of debridement or MF on the KOOS. No significant effects of debridement were detected in the unadjusted or adjusted regression analyses on any of the KOOS subscales at 2-year follow-up. The MF treatment of the cartilage lesions had significant negative effects at 2-year follow-up on the KOOS Sport and Recreation (Sport/Rec) (regression coefficient [β] = -8.9; 95% confidence interval [CI], -15.1 to -1.5) and Knee-Related Quality of Life (QoL) (β = -8.1; 95% CI, -14.1 to -2.1) subscales in the unadjusted analyses. When adjusting for confounders, MF had significant negative effects on the same KOOS subscales of Sport/Rec (β = -8.6; 95% CI, -16.4 to -0.7) and QoL (β = -7.2; 95% CI, -13.6 to -0.8). For the remaining KOOS subscales of Pain, Symptoms, and Activities of Daily Living, there were no significant unadjusted or adjusted effects of MF. MF of concomitant full-thickness cartilage lesions showed adverse effects on patient-reported outcomes at 2-year follow-up after ACL reconstruction. Debridement of concomitant full-thickness cartilage lesions showed neither positive nor negative effects on patient-reported outcomes at 2-year follow-up after ACL reconstruction. © 2015 The Author(s).

  6. In vitro co-culture of human skin keratinocytes and fibroblasts on a biocompatible and biodegradable scaffold.

    PubMed

    Pajoum Shariati, Seyed Ramin; Shokrgozar, Mohammad Ali; Vossoughi, Manouchehr; Eslamifar, Ali

    2009-07-01

    Extensive full-thickness burns require replacement of both epidermis and dermis. In designing skin replacements, the goal has been to re-create this model and make a product which has both essential components. In the present study, we developed procedures for establishing confluent, stratified layers of cultured human keratinocytes on the surface of modified collagen-chitosan scaffold that contains fibroblasts. The culture methods for propagation of keratinocytes and fibroblasts isolated from human neonatal foreskin were developed. The growth and proliferation of normal human keratinocytes were evaluated in serum-free (keratinocyte growth medium) and our modified medium. Characterization of human keratinocytes was determined by using pan-keratin and anti-involucrin monoclonal antibodies. For fabrication of relevant biodegradable and biocompatible collagen-chitosan porous scaffold with improved biostability, modified method of freeze-gelation was used. In generating organotypic co-cultures, epidermal keratinocytes were plated onto the upper surface of scaffold containing embedded fibroblasts. The results showed that the growth of isolated human skin fibroblasts and keratinocytes in our modified medium was more than that in the serum-free medium. The different evaluations of collagen-chitosan scaffold showed that it is relevant to growth of cells (fibroblast and keratinocyte) and has a good flexibility in manipulation of the living skin equivalents. These findings indicate that the integration of collagen-chitosan scaffold with co-cultured keratinocyte and fibroblast in vitro provides a potential source of living skin for grafting in vivo.

  7. Brugia malayi infective larvae fail to activate Langerhans cells and dermal dendritic cells in human skin.

    PubMed

    Cotton, R N; McDonald-Fleming, R; Boyd, A; Spates, K; Nutman, T B; Tolouei Semnani, R

    2015-02-01

    Filarial infection in humans is initiated when a mosquito deposits third-stage parasite larvae (L3) in the skin. Langerhans cells (LCs) and dermal dendritic cells (DDCs) are the first cells that the parasite encounters, and L3s must evade these highly effective antigen-presenting cells to establish infection. To assess LC and DDC responses to L3 in human skin, we employed three models of increasing physiologic relevance: in vitro-generated LCs, epidermal blister explants and full-thickness human skin sections. In vitro-generated LCs expressed TLR1-10 and robustly produced IL-6 and TNF-α in response to PolyI:C, but pre-exposure to L3s did not alter inflammatory cytokine production or TLR expression. L3s did not modulate expression of LC markers CDH1, CD207, or CD1a, or the regulatory products TSLP or IDO in epidermal explants or in vitro-generated LC. LC, CD14+ DDC, CD1c+ DC and CD141+ DC from human skin sections were analysed by flow cytometry. While PolyI:C potently induced CCL22 production in LC, CD1c+ DC, and CD141+ DC, and IL-10 production in LC, L3s did not modulate the numbers of or cytokine production by any skin DC subset. L3s broadly failed to activate or modulate LCs or DDCs, suggesting filarial larvae expertly evade APC detection in human skin. © 2014 John Wiley & Sons Ltd.

  8. In vivo measurements of cutaneous melanin across spatial scales: using multiphoton microscopy and spatial frequency domain spectroscopy

    PubMed Central

    Saager, Rolf B.; Balu, Mihaela; Crosignani, Viera; Sharif, Ata; Durkin, Anthony J.; Kelly, Kristen M.; Tromberg, Bruce J.

    2015-01-01

    Abstract. The combined use of nonlinear optical microscopy and broadband reflectance techniques to assess melanin concentration and distribution thickness in vivo over the full range of Fitzpatrick skin types is presented. Twelve patients were measured using multiphoton microscopy (MPM) and spatial frequency domain spectroscopy (SFDS) on both dorsal forearm and volar arm, which are generally sun-exposed and non-sun-exposed areas, respectively. Both MPM and SFDS measured melanin volume fractions between ∼5% (skin type I non-sun-exposed) and 20% (skin type VI sun exposed). MPM measured epidermal (anatomical) thickness values ∼30–65  μm, while SFDS measured melanin distribution thickness based on diffuse optical path length. There was a strong correlation between melanin concentration and melanin distribution (epidermal) thickness measurements obtained using the two techniques. While SFDS does not have the ability to match the spatial resolution of MPM, this study demonstrates that melanin content as quantified using SFDS is linearly correlated with epidermal melanin as measured using MPM (R2=0.8895). SFDS melanin distribution thickness is correlated to MPM values (R2=0.8131). These techniques can be used individually and/or in combination to advance our understanding and guide therapies for pigmentation-related conditions as well as light-based treatments across a full range of skin types. PMID:26065839

  9. Full-length silicone insoles versus ultrasound-guided corticosteroid injection in the management of plantar fasciitis: a randomized clinical trial.

    PubMed

    Yucel, Ufuk; Kucuksen, Sami; Cingoz, Havva T; Anliacik, Emel; Ozbek, Orhan; Salli, Ali; Ugurlu, Hatice

    2013-12-01

    Plantar fasciitis often leads to disability. Optimal treatment for this clinical condition is still unknown. To compare the effectiveness of wearing a full-length silicone insole with ultrasound-guided corticosteroid injection in the management of plantar fasciitis. Randomized clinical trial. Forty-two patients with chronic unilateral plantar fasciitis were allocated randomly to have an ultrasound-guided corticosteroid injection or wear a full-length silicone insole. Data were collected before the procedure and 1 month after. The primary outcome measures included first-step heel pain via Visual Analogue Scale and Heel Tenderness Index. Other outcome measures were the Foot and Ankle Outcome Score and ultrasonographic thickness of the plantar fascia. After 1 month, a significant improvement was shown in Visual Analogue Scale, Heel Tenderness Index, Foot and Ankle Outcome Score, and ultrasonographic thickness of plantar fascia in both groups. Visual Analogue Scale scores, Foot and Ankle Outcome Score pain, Foot and Ankle Outcome Score for activities of daily living, Foot and Ankle Outcome Score for sport and recreation function, and plantar fascia thickness were better in injection group than in insole group (p < 0.05). Although both ultrasound-guided corticosteroid injection and wearing a full-length silicone insole were effective in the conservative treatment of plantar fasciitis, we recommend the use of silicone insoles as a first line of treatment for persons with plantar fasciitis.

  10. Effects of half-wave and full-wave power source on the anodic oxidation process on AZ91D magnesium alloy

    NASA Astrophysics Data System (ADS)

    Wang, Ximei; Zhu, Liqun; Li, Weiping; Liu, Huicong; Li, Yihong

    2009-03-01

    Anodic films have been prepared on the AZ91D magnesium alloys in 1 mol/L Na 2SiO 3 with 10 vol.% silica sol addition under the constant voltage of 60 V at room temperature by half-wave and full-wave power sources. The weight of the anodic films has been scaled by analytical balance, and the thickness has been measured by eddy current instrument. The surface morphologies, chemical composition and structure of the anodic films have been characterized by scanning electron microscopy (SEM), energy dispersion spectrometry (EDS), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the thickness and weight of the anodic films formed by the two power sources both increase with the anodizing time, and the films anodized by full-wave power source grow faster than that by half-wave one. Furthermore, we have fitted polynomial to the scattered data of the weight and thickness in a least-squares sense with MATLAB, which could express the growth process of the anodic films sufficiently. The full-wave power source is inclined to accelerate the growth of the anodic films, and the half-wave one is mainly contributed to the uniformity and fineness of the films. The anodic film consists of crystalline Mg 2SiO 4 and amorphous SiO 2.

  11. Thickness of unconsolidated deposits of the Puget Sound aquifer system, Washington and British Columbia

    USGS Publications Warehouse

    Jones, M.A.

    1996-01-01

    The Puget-Willamette Lowland is located in western Washington, western Oregon, and a small part of southwestern British Columbia, Canada. The Puget-Willamette Lowland study area is composed of two distinct subareas, the Puget Sound Lowland and the Willamette Lowland. This report presents the results of mapping the thickness of the unconsolidated deposits in the Puget Sound Lowland. The thickness of the unconsolidated deposits ranges from a discontinuous veneer in areas of bedrock outcrop to more than 3,600 feet. Available information shows that the unconsolidated deposits are thickest in the Fraser-Whatcom, Everett, Seattle, and Tacoma Basins. The mapped thickness of the unconsolidated deposits in the Tacoma Basin is probably underestimated because of the scarcity of wells penetrating the full thickness of the unconsolidated deposits and the lack of sufficient marine-seismic data.

  12. Laser machining of southern pine

    Treesearch

    C. W. McMillin; J. E. Harry

    1971-01-01

    When cutting with an air-jet-assisted carbon-dioxide laser of 240 watts output power, maximum feed speed at the point of full penetration of the beam decreased with increasing workpiece thickness in both wet and dry samples; the trend was curvilinear. Feed speeds averaged 99.1 and 14.6 inches per minute for samples 0.25 and 1.00 inch thick, respectively. Somewhat...

  13. [Measurement and comparison of the spectral transmittance of cerinate porcelain and human enamel].

    PubMed

    Chen, Ji-Hua; Zhou, Guo-Feng; Wei, Zhang-Rui; Wang, Hui; Zhao, San-Jun

    2006-12-01

    To measure the spectral transmittance of Cerinate porcelain veneer and enamel in different color and different thickness. Samples of Cerinate porcelain veneers were prepared in different thickness (0.50 mm, 0.75 mm, 1.00 mm) and different Vita shade (A1, A2, A3). Enamel samples in shade A2 were made with three thickness (0.50 mm, 0.75 mm, 1.00 mm). A spectrophotometer with spectra range (380-800 nm) was employed to measure the spectral transmittance. Spectral transmittance decreased with the increasing in the thickness of specimens and decreasing in the color darkness. The transmittance of Cerinate porcelain veneer material and enamel in the same color and same thickness hadn't significant difference. The key factor to spectral transmittance of porcelain veneer materials is veneer's thickness, and the color of the materials has also some influence on it. Cerinate porcelain veneers can properly recover the transparency of teeth.

  14. Cortical thickness development of human primary visual cortex related to the age of blindness onset.

    PubMed

    Li, Qiaojun; Song, Ming; Xu, Jiayuan; Qin, Wen; Yu, Chunshui; Jiang, Tianzi

    2017-08-01

    Blindness primarily induces structural alteration in the primary visual cortex (V1). Some studies have found that the early blind subjects had a thicker V1 compared to sighted controls, whereas late blind subjects showed no significant differences in the V1. This implies that the age of blindness onset may exert significant effects on the development of cortical thickness of the V1. However, no previous research used a trajectory of the age of blindness onset-related changes to investigate these effects. Here we explored this issue by mapping the cortical thickness trajectory of the V1 against the age of blindness onset using data from 99 blind individuals whose age of blindness onset ranged from birth to 34 years. We found that the cortical thickness of the V1 could be fitted well with a quadratic curve in both the left (F = 11.59, P = 3 × 10 -5 ) and right hemispheres (F = 6.54, P = 2 × 10 -3 ). Specifically, the cortical thickness of the V1 thinned rapidly during childhood and adolescence and did not change significantly thereafter. This trend was not observed in the primary auditory cortex (A1), primary motor cortex (M1), or primary somatosensory cortex (S1). These results provide evidence that an onset of blindness before adulthood significantly affects the cortical thickness of the V1 and suggest a critical period for cortical development of the human V1.

  15. Anisotropic bioelectrical impedance determination of subcutaneous fat thickness

    NASA Astrophysics Data System (ADS)

    Hernández-Becerra, P. A. I.; Delgadillo-Holtfort, I.; Balleza-Ordaz, M.; Huerta-Franco, M. R.; Vargas-Luna, M.

    2014-11-01

    Preliminary results have shown that bioelectrical impedance measurements performed on different parts of the human body strongly depend upon the subcutaneous fat of the considered region. In this work, a method for the determination of subcutaneous fat thickness is explored. Within this method the measurement of the bioelectrical impedance response of the fat-muscle system, both along the direction defined by the muscle fibers and along the corresponding perpendicular direction, are performed. Measurements have been carried out on human female and male subjects of ages around 25 years old at the region of the biceps. Correlation has been performed with skinfold caliper measurements.

  16. Structural changes in socio-affective networks: Multi-modal MRI findings in long-term meditation practitioners.

    PubMed

    Engen, Haakon G; Bernhardt, Boris C; Skottnik, Leon; Ricard, Matthieu; Singer, Tania

    2017-08-31

    Our goal was to assess the effects of long-term mental training in socio-affective skills on structural brain networks. We studied a group of long-term meditation practitioners (LTMs) who have focused on cultivating socio-affective skills using loving-kindness and compassion meditation for an average of 40k h, comparing these to meditation-naïve controls. To maximize homogeneity of prior practice, LTMs were included only if they had undergone extensive full-time meditation retreats in the same center. MRI-based cortical thickness analysis revealed increased thickness in the LTM cohort relative to meditation-native controls in fronto-insular cortices. To identify functional networks relevant for the generation of socio-affective states, structural imaging analysis were complemented by fMRI analysis in LTMs, showing amplitude increases during a loving-kindness meditation session relative to non-meditative rest in multiple prefrontal and insular regions bilaterally. Importantly, functional findings partially overlapped with regions of cortical thickness increases in the left ventrolateral prefrontal cortex and anterior insula, suggesting that these regions may play a central role in the generation of emotional states relevant for the meditative practice. Our multi-modal MRI approach revealed structural changes in LTMs who have cultivated loving-kindness and compassion for a significant period of their life in functional networks activated by these practices. These preliminary cross-sectional findings motivate future longitudinal work studying brain plasticity following the regular practice of skills aiming at enhancing human altruism and prosocial motivation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [Experimental study on porcine acellular dermal matrix and split-thickness skin grafts to repair full-thickness skin defects].

    PubMed

    Ma, Shaoying; Li, Baoming; Wang, Xusheng; Li, Youchen; Kang, Yue; Dong, Li; Chen, Xueying; Zhao, Yaping; Li, Baoxing

    2010-02-01

    To compare the effect of the composite skin graft consisting of split-thickness skin grafts (STSGs) and porcine acellular dermal matrix (PADM) with STSGs only, and to histologically observe the turnover of the PADM in rats. Twenty female Sprague-Dawley rats, weighing 200-225 g, were included. The size of 4.0 cm x 2.5 cm PADM was implanted into hypoderm of the left side of Sprague-Dawley rats' back. After 10-14 days, the size of 4.0 cm x 2.5 cm full-thickness skin defects were made on the left to expose the PADM under the skin and the same size of full-thickness skin defects were made on the right of the rats' back. The excised full-thickness skin was made to STSGs about 0.2 mm by drum dermatome. The defects were grafted with composite skin (STSGs on the PADM, experimental group) and STSGs only (control group). The survival rate, the construction degree of grafts, and the histological change in grafts area were observed at 2, 4, 8, and 20 weeks after operation. At 2 weeks after STSGs (0.2 mm) placed on vascularized PADM, STSGs and PADM adhered together and the composite skin had a good survival. The control group also had a good survival. Histological observations showed that STSGs and PADM grew together, neutrophilic granulocytes and lymphocytes infiltrated in the PADM and some macrophages around the PADM. Fibrous connective tissues were filled under the STSGs in control group. At 4-8 weeks after transplantation, the composite skin had a good survival and the composite skin was thick, soft, and elastic. STSGs survived almost totally in control group, but the grafts were thin. Histological observations showed that inflammatory reactions of PADM faded gradually in experimental group; scar tissues formed under the STSGs in control group. At 20 weeks after transplantation, composite skin was flat, thick, and elastic in experimental group, but the STSGs were thinner and less elastic in control group. Histological observations showed that histological structures of the PADM were similar to the dermal matrix of rats, and the results showed that the collagen matrix of PADM was gradually replaced by the rats' collagen matrix. Scar tissues were filled under the STSGs in control group. Wound healing rates of experimental group were lower than those of control group at 4 and 8 weeks (P < 0.05); wound contraction rates of experimental group had lower tendency than those of control group, but showing no significant differences (P > 0.05). Coverage wound with composite skin which composed of STSGs and PADM could improve wound healing quality; the composite skin is thicker and better elastic than STSGs only. The collagen matrix of PADM is gradually replaced by rats' collagen matrix.

  18. Real time radiotherapy verification with Cherenkov imaging: development of a system for beamlet verification

    NASA Astrophysics Data System (ADS)

    Pogue, B. W.; Krishnaswamy, V.; Jermyn, M.; Bruza, P.; Miao, T.; Ware, William; Saunders, S. L.; Andreozzi, J. M.; Gladstone, D. J.; Jarvis, L. A.

    2017-05-01

    Cherenkov imaging has been shown to allow near real time imaging of the beam entrance and exit on patient tissue, with the appropriate intensified camera and associated image processing. A dedicated system has been developed for research into full torso imaging of whole breast irradiation, where the dual camera system captures the beam shape for all beamlets used in this treatment protocol. Particularly challenging verification measurement exists in dynamic wedge, field in field, and boost delivery, and the system was designed to capture these as they are delivered. Two intensified CMOS (ICMOS) cameras were developed and mounted in a breast treatment room, and pilot studies for intensity and stability were completed. Software tools to contour the treatment area have been developed and are being tested prior to initiation of the full trial. At present, it is possible to record delivery of individual beamlets as small as a single MLC thickness, and readout at 20 frames per second is achieved. Statistical analysis of system repeatibilty and stability is presented, as well as pilot human studies.

  19. Comparison of RNFL thickness and RPE-normalized RNFL attenuation coefficient for glaucoma diagnosis

    NASA Astrophysics Data System (ADS)

    Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.

    2013-03-01

    Recently, a method to determine the retinal nerve fiber layer (RNFL) attenuation coefficient, based on normalization on the retinal pigment epithelium, was introduced. In contrast to conventional RNFL thickness measures, this novel measure represents a scattering property of the RNFL tissue. In this paper, we compare the RNFL thickness and the RNFL attenuation coefficient on 10 normal and 8 glaucomatous eyes by analyzing the correlation coefficient and the receiver operator curves (ROCs). The thickness and attenuation coefficient showed moderate correlation (r=0.82). Smaller correlation coefficients were found within normal (r=0.55) and glaucomatous (r=0.48) eyes. The full separation between normal and glaucomatous eyes based on the RNFL attenuation coefficient yielded an area under the ROC (AROC) of 1.0. The AROC for the RNFL thickness was 0.9875. No statistically significant difference between the two measures was found by comparing the AROC. RNFL attenuation coefficients may thus replace current RNFL thickness measurements or be combined with it to improve glaucoma diagnosis.

  20. Investigation of Fumed Silica/Aqueous NaCl Superdielectric Material.

    PubMed

    Jenkins, Natalie; Petty, Clayton; Phillips, Jonathan

    2016-02-20

    A constant current charge/discharge protocol which showed fumed silica filled to the point of incipient wetness with aqueous NaCl solution to have dielectric constants >10⁸ over the full range of dielectric thicknesses of 0.38-3.9 mm and discharge times of 0.25->100 s was studied, making this material another example of a superdielectric. The dielectric constant was impacted by both frequency and thickness. For time to discharge greater than 10 s the dielectric constant for all thicknesses needed to be fairly constant, always >10⁸, although trending higher with increasing thickness. At shorter discharge times the dielectric constant consistently decreased, with decreasing time to discharge. Hence, it is reasonable to suggest that for time to discharge >10 s the dielectric constant at all thicknesses will be greater than 10⁸. This in turn implies an energy density for a 5 micron thick dielectric layer in the order of 350 J/cm³ for discharge times greater than 10 s.

  1. Investigation of Fumed Silica/Aqueous NaCl Superdielectric Material

    PubMed Central

    Jenkins, Natalie; Petty, Clayton; Phillips, Jonathan

    2016-01-01

    A constant current charge/discharge protocol which showed fumed silica filled to the point of incipient wetness with aqueous NaCl solution to have dielectric constants >108 over the full range of dielectric thicknesses of 0.38–3.9 mm and discharge times of 0.25–>100 s was studied, making this material another example of a superdielectric. The dielectric constant was impacted by both frequency and thickness. For time to discharge greater than 10 s the dielectric constant for all thicknesses needed to be fairly constant, always >109, although trending higher with increasing thickness. At shorter discharge times the dielectric constant consistently decreased, with decreasing time to discharge. Hence, it is reasonable to suggest that for time to discharge >10 s the dielectric constant at all thicknesses will be greater than 109. This in turn implies an energy density for a 5 micron thick dielectric layer in the order of 350 J/cm3 for discharge times greater than 10 s. PMID:28787918

  2. The Effects of Posterior Rotator Cuff Cable Tears on Glenohumeral Biomechanics in a Cadaveric Model of the Throwing Shoulder

    PubMed Central

    Photopoulos, Christos Demetris; ElAttrache, Neal S.; Doermann, Alex; Akeda, Masaki; McGarry, Michelle H.; Lee, Thay Q.

    2017-01-01

    Objectives: The rotator cuff cable has been postulated to be the primary load bearing substructure of the superior part of the rotator cuff. Tears of the posterior rotator cable are frequently seen in overhead throwing athletes. Although the biomechanical significance of the anterior rotator cable has been well described, our current understanding of the relevance of the posterior cable is limited. The purpose of this study was to examine how partial-thickness tears and full-thickness tears of the posterior rotator cable would alter glenohumeral biomechanics and kinematics in cadaveric shoulder models. Methods: Eight fresh-frozen cadaveric shoulder specimens were prepared and tested. To simulate the sequence of glenohumeral positions during the throwing motion, specimens were mounted on a custom shoulder testing system with the humerus positioned at 90° of abduction (30° scapular upward rotation, 60° glenohumeral abduction) and tested at 30, 60, 90, and 120 degrees of external rotation. After a circumferential capsulotomy was performed, rotator cuff muscles were loaded based on physiologic cross-sectional area ratios, and testing for each specimen was performed on each the following three conditions: intact posterior cable, partial-thickness (50%) articular-sided posterior cable tear, and full-thickness posterior cable tear. Primary outcome measures tested for each condition under the various degrees of glenohumeral rotation were: 1) anterior and total glenohumeral translation after application of a 30N anterior force; 2) path of glenohumeral articulation; 3) glenohumeral joint force. Results: With a 30N anterior force at 120° of external rotation, there was a significant increase in anterior glenohumeral translation between intact and full-thickness tear specimens (7.28±2.00mm and 17.49±3.75mm, respectively; p<0.05). Similarly, total joint translation at 120° of external rotation significantly increased between intact and full-thickness tear specimens (10.37±3.18mm and 23.37±5.05mm, respectively; p<0.05). No significant differences were apparent at other degrees of rotation (30, 60, 90 degrees), or with partial-thickness tears. Changes in the path of glenohumeral articulation were likewise most evident at 120° of external rotation, with a progressively anterior, inferior, and lateral shift in articulation with sequential sectioning of the posterior cable. Lastly, with regards to alterations in glenohumeral joint force, no significant changes were seen in any of the conditions. Conclusion: In this cadaveric shoulder model of the throwing shoulder, tears of the posterior rotator cuff cable lead to altered glenohumeral biomechanics and kinematics. These changes were most profound at 120° of external rotation, suggesting the importance of an intact posterior cable as a potential stabilizer during the late-cocking phase of throwing.

  3. Reducing lumber thickness variation using real-time statistical process control

    Treesearch

    Thomas M. Young; Brian H. Bond; Jan Wiedenbeck

    2002-01-01

    A technology feasibility study for reducing lumber thickness variation was conducted from April 2001 until March 2002 at two sawmills located in the southern U.S. A real-time statistical process control (SPC) system was developed that featured Wonderware human machine interface technology (HMI) with distributed real-time control charts for all sawing centers and...

  4. Brief communication: Enamel thickness and durophagy in mangabeys revisited.

    PubMed

    McGraw, W Scott; Pampush, James D; Daegling, David J

    2012-02-01

    The documentation of enamel thickness variation across primates is important because enamel thickness has both taxonomic and functional relevance. The Old World monkeys commonly referred to as mangabeys have figured prominently in investigations of feeding ecology and enamel thickness. In this article, we report enamel thickness values for four mangabey taxa (Cercocebus atys, Cercocebus torquatus, Lophocebus aterrimus, and Lophocebus albigena), offer revised interpretation of the significance of thick enamel in papionin evolution, and place our new data in a broader comparative framework. Our data indicate that all mangabeys have thick enamel and that the values obtained for Cercocebus and Lophocebus equal or exceed those published for most extant non-human primates. In addition, new field data combined with a current reading of the dietary literature indicate that hard foods make up a portion of the diet of every mangabey species sampled to date. Clarification on the relationship between diet and enamel thickness among mangabeys is important not only because of recognition that mangabeys are not a natural group but also because of recent arguments that explain thick enamel as an evolved response to the seasonal consumption of hard foods. Copyright © 2011 Wiley Periodicals, Inc.

  5. Determining the origin of cells in tissue engineered skin substitutes: a pilot study employing in situ hybridization.

    PubMed

    Weber, Andreas Daniel; Pontiggia, Luca; Biedermann, Thomas; Schiestl, Clemens; Meuli, Martin; Reichmann, Ernst

    2011-03-01

    Definitive and high-quality coverage of large and, in particular, massive skin defects remains a significant challenge in burn as well as plastic and reconstructive surgery because of donor site shortage. A novel and promising approach to overcome these problems is tissue engineering of skin. Clearly, before eventual clinical application, engineered skin substitutes of human origin must be grafted and then evaluated in animal models. For the various tests to be conducted it is indispensable to be able to identify human cells as such in culture and also to distinguish between graft and recipient tissue after transplantation. Here we describe a tool to identify human cells in vitro and in vivo. In situ hybridization allows for the detection and localization of specific DNA or RNA sequences in morphologically preserved cells in culture or tissue sections, respectively. We used digoxigenin-labeled DNA probes corresponding to human-specific Alu repeats in order to identify human keratinocytes grown in culture together with rat cells, and also to label split and full thickness skin grafts of human origin after transplantation on immuno-incompetent rats. Digoxigenin-labeled DNA probing resulted in an intensive nuclear staining of human cells, both in culture and after transplantation onto recipient animals, while recipient animal cells (rat cells) did not stain. In situ hybridization using primate-specific Alu probes reliably allows distinguishing between cells of human and non-human origin both in culture as well as in histological sections. This method is an essential tool for those preclinical experiments (performed on non-primate animals) that must be conducted before novel tissue engineered skin substitutes might be introduced into clinical practice.

  6. Increased-resolution OCT thickness mapping of the human macula: a statistically based registration.

    PubMed

    Bernardes, Rui; Santos, Torcato; Cunha-Vaz, José

    2008-05-01

    To describe the development of a technique that enhances spatial resolution of retinal thickness maps of the Stratus OCT (Carl Zeiss Meditec, Inc., Dublin, CA). A retinal thickness atlas (RT-atlas) template was calculated, and a macular coordinate system was established, to pursue this objective. The RT-atlas was developed from principal component analysis of retinal thickness analyzer (RTA) maps acquired from healthy volunteers. The Stratus OCT radial thickness measurements were registered on the RT-atlas, from which an improved macular thickness map was calculated. Thereafter, Stratus OCT circular scans were registered on the previously calculated map to enhance spatial resolution. The developed technique was applied to Stratus OCT thickness data from healthy volunteers and from patients with diabetic retinopathy (DR) or age-related macular degeneration (AMD). Results showed that for normal, or close to normal, macular thickness maps from healthy volunteers and patients with DR, this technique can be an important aid in determining retinal thickness. Efforts are under way to improve the registration of retinal thickness data in patients with AMD. The developed technique enhances the evaluation of data acquired by the Stratus OCT, helping the detection of early retinal thickness abnormalities. Moreover, a normative database of retinal thickness measurements gained from this technique, as referenced to the macular coordinate system, can be created without errors induced by missed fixation and eye tilt.

  7. The Gradual Expansion Muscle Flap

    DTIC Science & Technology

    2014-01-01

    acute shortening and angulation of the tibia and rotational muscle flap coverage and split thickness skin grafting of the soft tissue defect...is also amenable to split-thickness skin grafting after tissue incorporation.11 In addition to donor site morbidity, free tissue transfer is dependent...necessary soft tissue coverage. In the second stage, after the flap has adequately set and overlying skin graft has full adherence, a Taylor Spatial

  8. Human Chorioretinal Layer Thicknesses Measured in Macula-wide, High-Resolution Histologic Sections

    PubMed Central

    Messinger, Jeffrey D.; Sloan, Kenneth R.; Mitra, Arnab; McGwin, Gerald; Spaide, Richard F.

    2011-01-01

    Purpose. To provide a comprehensive description of chorioretinal layer thicknesses in the normal human macula, including two-layer pairs that can produce a combined signal in some optical coherence tomography (OCT) devices (ganglion cell [GCL] and inner plexiform [IPL] layers and outer plexiform [OPL] and outer nuclear [ONL] layers). Methods. In 0.8-μm-thick, macula-wide sections through the foveola of 18 donors (age range, 40–92 years), 21 layers were measured at 25 locations by a trained observer and validated by a second observer. Tissue volume changes were assessed by comparing total retinal thickness in ex vivo OCT and in sections. Results. Median tissue shrinkage was 14.5% overall and 29% in the fovea. Histologic laminar boundaries resembled those in SD-OCT scans, but the shapes of the foveolar OPL and ONL differed. Histologic GCL, IPL, and OPLHenle were thickest at 0.8. to 1, 1.5, and 0.4 mm eccentricity, respectively. ONL was thickest in an inward bulge at the foveal center. At 1 mm eccentricity, GCL, INL, and OPLHenle represented 17.3% to 21.1%, 18.0% to 18.5%, and 14.2% to 16.6% of total retinal thickness, respectively. In donors ≥70 years of age, the RPE and choroid were 17.1% and 29.6% thinner and OPLHenle was 20.8% thicker than in donors <70 years. Conclusions. In this study, the first graphic representation and thickness database of chorioretinal layers in normal macula were generated. Newer OCT systems can separate GCL from IPL and OPLHenle from ONL, with good agreement for the proportion of retinal thickness occupied by OPLHenle in OCT and histology. The thickening of OPLHenle in older eyes may reflect Müller cell hypertrophy associated with rod loss. PMID:21421869

  9. Quantification of thickness loss in a liquid-loaded plate using ultrasonic guided wave tomography

    NASA Astrophysics Data System (ADS)

    Rao, Jing; Ratassepp, Madis; Fan, Zheng

    2017-12-01

    Ultrasonic guided wave tomography (GWT) provides an attractive solution to map thickness changes from remote locations. It is based on the velocity-to-thickness mapping employing the dispersive characteristics of selected guided modes. This study extends the application of GWT on a liquid-loaded plate. It is a more challenging case than the application on a free plate, due to energy of the guided waves leaking into the liquid. In order to ensure the accuracy of thickness reconstruction, advanced forward models are developed to consider attenuation effects using complex velocities. The reconstruction of the thickness map is based on the frequency-domain full waveform inversion (FWI) method, and its accuracy is discussed using different frequencies and defect dimensions. Validation experiments are carried out on a water-loaded plate with an irregularly shaped defect using S0 guided waves, showing excellent performance of the reconstruction algorithm.

  10. Assessing microstructures of the cornea with Gabor-domain optical coherence microscopy: pathway for corneal physiology and diseases.

    PubMed

    Tankam, Patrice; He, Zhiguo; Chu, Ying-Ju; Won, Jungeun; Canavesi, Cristina; Lepine, Thierry; Hindman, Holly B; Topham, David J; Gain, Philippe; Thuret, Gilles; Rolland, Jannick P

    2015-03-15

    Gabor-domain optical coherence microscopy (GD-OCM) was applied ex vivo in the investigation of corneal cells and their surrounding microstructures with particular attention to the corneal endothelium. Experiments using fresh pig eyeballs, excised human corneal buttons from patients with Fuchs' endothelial dystrophy (FED), and healthy donor corneas were conducted. Results show in a large field of view (1  mm×1  mm) high definition images of the different cell types and their surrounding microstructures through the full corneal thickness at both the central and peripheral locations of porcine corneas. Particularly, an image of the endothelial cells lining the bottom of the cornea is highlighted. As compared to healthy human corneas, the corneas of individuals with FED show characteristic microstructural alterations of the Descemet's membrane and increased size and number of keratocytes. The GD-OCM-based imaging system developed may constitute a novel tool for corneal imaging and disease diagnosis. Also, importantly, it may provide insights into the mechanism of corneal physiology and pathology, particularly in diseases of the corneal endothelium.

  11. Modeling the influence of LASIK surgery on optical properties of the human eye

    NASA Astrophysics Data System (ADS)

    Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina

    2011-11-01

    The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.

  12. Spontaneous closure of traumatic macular hole.

    PubMed

    Sanjay, Srinivasan; Yeo, Tun Kuan; Au Eong, Kah-Guan

    2012-07-01

    Macular hole formation is a well-known complication following ocular trauma. Less commonly recognised is the spontaneous closure of such holes. A 27-year-old man presented with a history of blunt trauma to his left eye. Eye evaluation showed conjunctival laceration, diffuse retinal oedema and multiple retinal haemorrhages in that eye. A month later, he developed a full thickness macular hole. Two months later, there was spontaneous complete closure of the full-thickness macular hole in the left eye as confirmed on optical coherence tomography. Spontaneous closure of hole is not uncommon. Observation for a period of up to 12 months is a reasonable management option. Macular hole surgery for traumatic macular holes may be delayed in such cases.

  13. Leaf Shrinkage with Dehydration: Coordination with Hydraulic Vulnerability and Drought Tolerance1[C][W][OPEN

    PubMed Central

    Scoffoni, Christine; Vuong, Christine; Diep, Steven; Cochard, Hervé; Sack, Lawren

    2014-01-01

    Leaf shrinkage with dehydration has attracted attention for over 100 years, especially as it becomes visibly extreme during drought. However, little has been known of its correlation with physiology. Computer simulations of the leaf hydraulic system showed that a reduction of hydraulic conductance of the mesophyll pathways outside the xylem would cause a strong decline of leaf hydraulic conductance (Kleaf). For 14 diverse species, we tested the hypothesis that shrinkage during dehydration (i.e. in whole leaf, cell and airspace thickness, and leaf area) is associated with reduction in Kleaf at declining leaf water potential (Ψleaf). We tested hypotheses for the linkage of leaf shrinkage with structural and physiological water relations parameters, including modulus of elasticity, osmotic pressure at full turgor, turgor loss point (TLP), and cuticular conductance. Species originating from moist habitats showed substantial shrinkage during dehydration before reaching TLP, in contrast with species originating from dry habitats. Across species, the decline of Kleaf with mild dehydration (i.e. the initial slope of the Kleaf versus Ψleaf curve) correlated with the decline of leaf thickness (the slope of the leaf thickness versus Ψleaf curve), as expected based on predictions from computer simulations. Leaf thickness shrinkage before TLP correlated across species with lower modulus of elasticity and with less negative osmotic pressure at full turgor, as did leaf area shrinkage between full turgor and oven desiccation. These findings point to a role for leaf shrinkage in hydraulic decline during mild dehydration, with potential impacts on drought adaptation for cells and leaves, influencing plant ecological distributions. PMID:24306532

  14. Feasibility and Advantages of Full Thickness Skin Graft from the Anterolateral Thigh.

    PubMed

    Shin, Seung-Han; Kim, Chulkyu; Lee, Yong-Suk; Kang, Jin-Woo; Chung, Yang-Guk

    2017-12-01

    Full thickness skin graft (FTSG) gives better outcomes than split thickness skin graft (STSG), but it has the drawback of limited donor sites. Anterolateral thigh (ALT), a popular donor site of STSG, is also a popular donor site of perforator flaps. This area has the advantage of large flap size available with primary closure. Based on this we harvested FTSG instead of STSG from the ALT. We retrospectively reviewed 10 cases of FTSG from the ALT, with the recipient site of foot in 3, ankle in 2, lower leg in 2, forearm in 2, and wrist in 1 patient. In all cases elliptical full thickness skin was harvested from the ALT, and the donor site was closed primarily. The skin was defatted and placed onto the defect with vacuum-assisted closure (VAC). The skin size ranged 7-30 cm in length and 3-12 cm in width. Mean follow up period was 7 months (range, 3-13). FTSG from the ALT provided durable wound coverage, with excellent color and texture matching. Partial (< 20%) graft failure was observed in 1 case, but no additional surgery was necessary. No patient reported donor site pain at postoperative 2 weeks. No donor site complications were encountered. No patient complained a feeling of tension in the thigh at final follow-up. FTSG from the ALT is feasible with the aid of VAC. Considering the skin quality, large skin size available, early pain relief, and little donor site morbidity, the ALT should be revisited as a donor site of FTSG.

  15. Retention of a reconstructed nipple using a C-V flap with different layer thicknesses in the C-flap.

    PubMed

    Sowa, Yoshihiro; Itsukage, Sizu; Sakaguchi, Kouichi; Taguchi, Tetsuya; Numajiri, Toshiaki

    2018-04-01

    The C-V flap for nipple reconstruction is now one of standard surgical techniques. But decreased projection is still a problem. In recent years, it has been suggested that projection can be more easily maintained when raising of the C-flap is performed with a split thickness dermis. In this study, we examined whether decrease of projection can be prevented by raising of a C-flap with a split dermis rather than with full dermis. A total of 49 consecutive patients who underwent reconstruction of a nipple using the C-V flap technique were enrolled. The patients included 22 who underwent surgery using a C-flap with a full thickness dermis (Group F), and 27 who underwent surgery with raising of a flap with a split thickness dermis (Group S). The size of the reconstructed nipple was measured at 2 weeks, 6 months and 1 year postoperatively for comparison between Groups F and S. Partial necrosis of the C-flap end occurred in 4 subjects in only Group S. The decrease in projection after 1 year postoperatively in Group S was significantly lower than that in Group F. In contrast, the teat base size in Group F tended to be greater than that in Group S, suggesting a tendency for an expanded base using a flap with a full dermis. Our results indicated that it is recommended to use a C-flap with a split dermis for cases with high projection of the nipple on the contralateral side.

  16. Leaf shrinkage with dehydration: coordination with hydraulic vulnerability and drought tolerance.

    PubMed

    Scoffoni, Christine; Vuong, Christine; Diep, Steven; Cochard, Hervé; Sack, Lawren

    2014-04-01

    Leaf shrinkage with dehydration has attracted attention for over 100 years, especially as it becomes visibly extreme during drought. However, little has been known of its correlation with physiology. Computer simulations of the leaf hydraulic system showed that a reduction of hydraulic conductance of the mesophyll pathways outside the xylem would cause a strong decline of leaf hydraulic conductance (K(leaf)). For 14 diverse species, we tested the hypothesis that shrinkage during dehydration (i.e. in whole leaf, cell and airspace thickness, and leaf area) is associated with reduction in K(leaf) at declining leaf water potential (Ψ(leaf)). We tested hypotheses for the linkage of leaf shrinkage with structural and physiological water relations parameters, including modulus of elasticity, osmotic pressure at full turgor, turgor loss point (TLP), and cuticular conductance. Species originating from moist habitats showed substantial shrinkage during dehydration before reaching TLP, in contrast with species originating from dry habitats. Across species, the decline of K(leaf) with mild dehydration (i.e. the initial slope of the K(leaf) versus Ψ(leaf) curve) correlated with the decline of leaf thickness (the slope of the leaf thickness versus Ψ(leaf) curve), as expected based on predictions from computer simulations. Leaf thickness shrinkage before TLP correlated across species with lower modulus of elasticity and with less negative osmotic pressure at full turgor, as did leaf area shrinkage between full turgor and oven desiccation. These findings point to a role for leaf shrinkage in hydraulic decline during mild dehydration, with potential impacts on drought adaptation for cells and leaves, influencing plant ecological distributions.

  17. Magma Supply of Southwest Indian Ocean: Implication from Crustal Thickness Anomalies

    NASA Astrophysics Data System (ADS)

    Chiheng, L.; Jianghai, L.; Huatian, Z.; Qingkai, F.

    2017-12-01

    The Southwest Indian Ridge (SWIR) is one of the world's slowest spreading ridges with a full spreading rate of 14mm a-1, belonging to ultraslow spreading ridge, which are a novel class of spreading centers symbolized by non-uniform magma supply and crustal accretion. Therefore, the crustal thickness of Southwest Indian Ocean is a way to explore the magmatic and tectonic process of SWIR and the hotspots around it. Our paper uses Residual Mantle Bouguer Anomaly processed with the latest global public data to invert the relative crustal thickness and correct it according to seismic achievements. Gravity-derived crustal thickness model reveals a huge range of crustal thickness in Southwest Indian Ocean from 0.04km to 24km, 7.5km of average crustal thickness, and 3.5km of standard deviation. In addition, statistics data of crustal thickness reveal the frequency has a bimodal mixed skewed distribution, which indicates the crustal accretion by ridge and ridge-plume interaction. Base on the crustal thickness model, we divide three types of crustal thickness in Southwest Indian Ocean. About 20.31% of oceanic crust is <4.8km thick designated as thin crust, and 60.99% is 4.8-9.8km thick as normal crust. The remaining 18.70% is >9.8km thick as thick crust. Furthermore, Prominent thin crust anomalies are associated with the trend of most transform faults, but thick crust anomalies presents to northeast of Andrew Bain transform fault. Cold and depleted mantle are also the key factors to form the thin crust. The thick crust anomalies are constrained by hotspots, which provide abundant heat to the mantle beneath mid-ocean ridge or ocean basin. Finally, we roughly delineate the range of ridge-plume interaction and transform fault effect.

  18. Viable placental allograft as a biological dressing in the clinical management of full-thickness thermal occupational burns

    PubMed Central

    Johnson, Eric L.; Tassis, Elisabet K.; Michael, Georgina M.; Whittinghill, Susan G.

    2017-01-01

    Abstract Rationale: Occupational burn injuries can be detrimental and difficult to manage. The majority of complex cases are referred and managed at regional burn centers where access to specialized care is available. As an alternative to hospitalization with staged surgical procedures, placental products may be used for outpatient medical management of these common burn injuries, especially if access to a regional burn center is limited or restricted. Fresh amnion has been a treatment of choice in burns for more than 100 years. As a biological covering with a broad scope of potential uses, human placental membranes represent a dressing that is particularly advantageous for burn therapy. Recent advances in tissue-preservation technology have allowed for the commercialization of placental amnion products. Patient concerns: To address several complications associated with burn injuries—contractures, scar formation, and pain—a viable cryopreserved placental membrane (vCPM) (Grafix—PRIME, Osiris Therapeutics, Inc., MD) retaining the anti-inflammatory, anti-fibrotic, and antimicrobial properties of fresh placental tissues was chosen for clinical use in the 2 cases reported, where both patients had restricted access to the regional burn center. Diagnoses: Two cases of work-related extremity burns presented to a local rural hospital for immediate post-injury assessment. The 1st case was of a man who sustained a 55.4 cm2 full-thickness 3rd degree thermal burn with exposed bone and tendon, to the left dorsal forefoot after having an industrial pressure washer caught on his work boot. The 2nd case was of a female who sustained a 4.7 cm2 full-thickness 3rd degree crush burn to the dorsum extensor surface of her dominant hand's index finger after applying 80-pounds per square inch of heated pressure from a hydraulic press. Interventions: Both burn patients elected to continue their care at the outpatient-based wound and hyperbaric center, receiving a combination of weekly ad libitum debridement, applications of vCPM, and occupational therapy. Outcomes: Both burns reached timely wound closure, and patients regained full range of motion of the affected limb, allowing for early return to work. The average number of allograft applications was 7.5, allowing both patients to return to work in an average of 63.5 days without adverse events or post-treatment complications. Lessons: The incorporation of this product in the treatment of these complex burns prevented amputation in one patient, and skin autografting and potential index finger contracture-formation in the second patient. The incorporation of vCPM in burn management may offer a new approach to outpatient burn management and may mitigate several of the complications seen post burn injury, leading to favorable patient outcomes. PMID:29245303

  19. Macular hole in juvenile X-linked retinoschisis.

    PubMed

    Al-Swaina, Nayef; Nowilaty, Sawsan R

    2013-10-01

    An 18 year-old male with no antecedent of trauma, systemic syndrome or myopia was referred for surgical treatment of a full thickness macular hole in the left eye. A more careful inspection revealed discrete foveal cystic changes in the fellow eye and subtle peripheral depigmented retinal pigment epithelial changes in both eyes. A spectral-domain optical coherence tomography (SD-OCT) scan confirmed, in addition to the full thickness macular hole in the left eye, microcystic spaces in the nuclear layers of both retinae. The diagnosis of X-linked retinoschisis was confirmed with a full field electroretinogram displaying the typical negative ERG. Macular holes are uncommon in the young and those complicating X-linked retinoschisis are rare. This report highlights the importance of investigating the presence of a macular hole in a young patient and illustrates the clinical and SD-OCT clues beyond the foveal center which led to the correct diagnosis of X-linked juvenile retinoschisis.

  20. PDGF-BB Does Not Accelerate Healing in Diabetic Mice with Splinted Skin Wounds

    PubMed Central

    Shah, Nihar M.; Teixeira, Leandro; Motta, Monica J.; Covert, Jill; Dubielzig, Richard; Schurr, Michael; Isseroff, Roslyn Rivkah; Abbott, Nicholas L.; McAnulty, Jonathan; Murphy, Christopher J.

    2014-01-01

    Topical application of platelet-derived growth factor-BB (PDGF-BB) is considered to accelerate tissue repair of impaired chronic wounds. However, the vast literature is plagued with conflicting reports of its efficacy in animal models and this is often influenced by a wide array of experimental variables making it difficult to compare the results across the studies. To mitigate the confounding variables that influence the efficacy of topically applied PDGF-BB, we used a controlled full thickness splinted excisional wound model in db/db mice (type 2 diabetic mouse model) for our investigations. A carefully-defined silicone-splinted wound model, with reduced wound contraction, controlled splint and bandage maintenance, allowing for healing primarily by reepithelialization was employed. Two splinted 8 mm dorsal full thickness wounds were made in db/db mice. Wounds were topically treated once daily with either 3 µg PDGF-BB in 30 µl of 5% PEG-PBS vehicle or an equal volume of vehicle for 10 days. Body weights, wound contraction, wound closure, reepithelialization, collagen content, and wound bed inflammation were evaluated clinically and histopathologically. The bioactivity of PDGF-BB was confirmed by in vitro proliferation assay. PDGF-BB, although bioactive in vitro, failed to accelerate wound healing in vivo in the db/db mice using the splinted wound model. Considering that the predominant mechanism of wound healing in humans is by re-epeithelialization, the most appropriate model for evaluating therapeutics is one that uses splints to prevent excessive wound contraction. Here, we report that PDGF-BB does not promote wound closure by re-epithelialization in a murine splinted wound model. Our results highlight that the effects of cytoactive factors reported in vivo ought to be carefully interpreted with critical consideration of the wound model used. PMID:25121729

  1. Intestinal Leiomyositis: A Cause of Chronic Intestinal Pseudo-Obstruction in 6 Dogs.

    PubMed

    Zacuto, A C; Pesavento, P A; Hill, S; McAlister, A; Rosenthal, K; Cherbinsky, O; Marks, S L

    2016-01-01

    Intestinal leiomyositis is a suspected autoimmune disorder affecting the muscularis propria layer of the gastrointestinal tract and is a cause of chronic intestinal pseudo-obstruction in humans and animals. To characterize the clinical presentation, histopathologic features, and outcome of dogs with intestinal leiomyositis in an effort to optimize treatment and prognosis. Six client-owned dogs. Retrospective case series. Medical records were reviewed to describe signalment, clinicopathologic and imaging findings, histopathologic diagnoses, treatment, and outcome. All biopsy specimens were reviewed by a board-certified pathologist. Median age of dogs was 5.4 years (range, 15 months-9 years). Consistent clinical signs included vomiting (6/6), regurgitation (2/6), and small bowel diarrhea (3/6). Median duration of clinical signs before presentation was 13 days (range, 5-150 days). Diagnostic imaging showed marked gastric distension with dilated small intestines in 4/6 dogs. Full-thickness intestinal biopsies were obtained in all dogs by laparotomy. Histopathology of the stomach and intestines disclosed mononuclear inflammation, myofiber degeneration and necrosis, and fibrosis centered within the region of myofiber loss in the intestinal muscularis propria. All dogs received various combinations of immunomodulatory and prokinetic treatment, antimicrobial agents, antiemetics, and IV fluids, but none of the dogs showed a clinically relevant improvement with treatment. Median survival was 19 days after diagnosis (range, 3-270 days). Intestinal leiomyositis is a cause of intestinal pseudo-obstruction and must be diagnosed by full-thickness intestinal biopsy. This disease should be considered in dogs with acute and chronic vomiting, regurgitation, and small bowel diarrhea. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  2. Diagnosis at a glance of biological non-Newtonian fluids with Film Interference Flow Imaging (FIFI)

    NASA Astrophysics Data System (ADS)

    Hidema, R.; Yamada, N.; Furukawa, H.

    2012-04-01

    In the human body, full of biological non-Newtonian fluids exist. For example, synovial fluids exist in our joints, which contain full of biopolymers, such as hyaluronan and mucin. It is thought that these polymers play critical roles on the smooth motion of the joint. Indeed, luck of biopolymers in synovial fluid cause joint pain. Here we study the effects of polymer in thin liquid layer by using an original experimental method called Film Interference Flow Imaging (FIFI). A vertically flowing soap film containing polymers is made as two-dimensional flow to observe turbulence. The thickness of water layer is about 4 μm sandwiched between surfactant mono-layers. The interference pattern of the soap film is linearly related to the flow velocity in the water layer through the change in the thickness of the film. Thus the flow velocity is possibly analyzed by the single image analysis of the interference pattern, that is, FIFI. The grid turbulence was made in the flowing soap films containing the long flexible polymer polyethyleneoxide (PEO, Mw=3.5x106), and rigid polymer hydroxypropyl cellulose (HPC, Mw > 1.0 x106). The decaying process of the turbulence is affected by PEO and HPC at several concentrations. The effects of PEO are sharply seen even at low concentrations, while the effects of HPC are gradually occurred at much higher concentration compared to the PEO. It is assumed that such a difference between PEO and HPC is due to the polymer stretching or polymer orientation under turbulence, which is observed and analyzed by FIFI. We believe the FIFI will be applied in the future to examine biological fluids such as synovial fluids quickly and quantitatively.

  3. Different wound healing properties of dermis, adipose, and gingiva mesenchymal stromal cells.

    PubMed

    Boink, Mireille A; van den Broek, Lenie J; Roffel, Sanne; Nazmi, Kamran; Bolscher, Jan G M; Gefen, Amit; Veerman, Enno C I; Gibbs, Susan

    2016-01-01

    Oral wounds heal faster and with better scar quality than skin wounds. Deep skin wounds where adipose tissue is exposed, have a greater risk of forming hypertrophic scars. Differences in wound healing and final scar quality might be related to differences in mesenchymal stromal cells (MSC) and their ability to respond to intrinsic (autocrine) and extrinsic signals, such as human salivary histatin, epidermal growth factor, and transforming growth factor beta1. Dermis-, adipose-, and gingiva-derived MSC were compared for their regenerative potential with regards to proliferation, migration, and matrix contraction. Proliferation was assessed by cell counting and migration using a scratch wound assay. Matrix contraction and alpha smooth muscle actin was assessed in MSC populated collagen gels, and also in skin and gingival full thickness tissue engineered equivalents (reconstructed epithelium on MSC populated matrix). Compared to skin-derived MSC, gingiva MSC showed greater proliferation and migration capacity, and less matrix contraction in full thickness tissue equivalents, which may partly explain the superior oral wound healing. Epidermal keratinocytes were required for enhanced adipose MSC matrix contraction and alpha smooth muscle actin expression, and may therefore contribute to adverse scarring in deep cutaneous wounds. Histatin enhanced migration without influencing proliferation or matrix contraction in all three MSC, indicating that salivary peptides may have a beneficial effect on wound closure in general. Transforming growth factor beta1 enhanced contraction and alpha smooth muscle actin expression in all three MSC types when incorporated into collagen gels. Understanding the mechanisms responsible for the superior oral wound healing will aid us to develop advanced strategies for optimal skin regeneration, wound healing and scar formation. © 2015 by the Wound Healing Society.

  4. Healing Rates in a Multicenter Assessment of a Sterile, Room Temperature, Acellular Dermal Matrix Versus Conventional Care Wound Management and an Active Comparator in the Treatment of Full-Thickness Diabetic Foot Ulcers.

    PubMed

    Walters, Jodi; Cazzell, Shawn; Pham, Hau; Vayser, Dean; Reyzelman, Alexander

    2016-01-01

    The purpose of this 16-week, multicenter, randomized, controlled trial was to assess the healed ulcer rate of a human acellular dermal matrix, DermACELL, compared with conventional care and a second acellular dermal matrix, Graftjacket, in the treatment of full-thickness diabetic foot ulcers. One hundred sixty-eight patients were randomized into DermACELL, conventional care, and Graftjacket treatment arms in a 2:2:1 ratio. Patients in the acellular dermal matrix groups received either 1 or 2 applications of the graft at the discretion of the investigator. Weekly follow-up visits were conducted until the ulcer healed or the endpoint was reached. At 16 weeks, the DermACELL arm had a significantly higher proportion of completely healed ulcers than the conventional care arm (67.9% vs 48.1%; P = .0385) and a nonsignificantly higher proportion than the Graftjacket arm (67.9% vs 47.8%; P = .1149). The DermACELL arm also exhibited a greater average percent reduction in wound area than the conventional care arm (91.4% vs 80.3%; P = .0791) and the Graftjacket arm (91.4% vs 73.5%; P = .0762). The proportion of severe adverse events and the proportion of overall early withdrawals were similar among the 3 groups based on relative population size (P ≥ .05). The results presented here indicate that DermACELL is an appropriate clinical option in the treatment of diabetic foot ulcers, with significant increases in healing rates and rate of percentage wound closure as compared with conventional care options.

  5. Bilateral lower limb amputations in a nigerian child following high-voltage electrical burns injury: a case report.

    PubMed

    Dim, Em; Amanari, Oc; Nottidge, Te; Inyang, Uc; Nwashindi, A

    2013-07-01

    The human body conducts electricity very well. Direct contact with electric current can be lethal. The passage of electric current through the body is capable of producing a wide spectrum of injuries, including serious damage to the heart, brain, skin and muscles. Naked high-voltage electric cables negligently abandoned in residential, commercial and industrial areas are a recipe for disaster. This is a case report of a 5-year girl child who had bilateral lower limb gangrene following electrical burns injury. She presented with a fourday history of electrical burns injuries of both lower limbs including both gluteal regions, associated with a three-day history of fever, with full thickness burns and sepsis, ultimately leading to bilateral above knee guillotine amputations. High-voltage electric current, bilateral lower limb gangrene, bilateral above knee amputation.

  6. Quantitative 3-D Corneal Imaging In Vivo Using a Modified HRT- RCM Confocal Microscope

    PubMed Central

    Petroll, W. Matthew.; Weaver, Matthew; Vaidya, Saurabh; McCulley, James P.; Cavanagh, H. Dwight

    2012-01-01

    Purpose The purpose of this study was to develop and test hardware and software modifications to allow quantitative full-thickness corneal imaging using the HRT Rostock Corneal Module. Methods A PC-controlled motor drive with positional feedback was integrated into the system to allow automated focusing through the entire cornea. The left eyes of ten New Zealand White rabbits were scanned from endothelium to epithelium. Image sequences were read into a custom-developed program for depth calculation and measurement of sub-layer thicknesses. 3-D visualizations were also generated using Imaris. In six rabbits, stack images were registered, and depth-dependent counts of keratocyte nuclei were made using Metamorph. Results The mean epithelial and corneal thicknesses measured in the rabbit were 47 ± 5 μm and 373 ± 25 μm, respectively (N = 10 corneas); coefficients of variation for repeated scans were 8.2% and 2.1%. Corneal thickness measured using ultrasonic pachymetry was 374 ± 17 μm. The mean overall keratocyte density measured in the rabbit was 43,246 ± 5,603 cells/mm3 in vivo (N = 6 corneas). There was a gradual decrease in keratocyte density from the anterior to posterior cornea (R = 0.99), consistent with previous data generated in vitro. Conclusions This modified system allows high resolution 3-D image stacks to be collected from the full thickness rabbit cornea in vivo. These datasets can be used for interactive visualization of corneal cell layers, measurement of sub-layer thickness, and depth-dependent keratocyte density measurements. Overall, the modifications significantly expand the potential quantitative research applications of the HRT-RCM microscope. PMID:23051907

  7. Role of geometric parameters in electrical measurements of insulating thin films deposited on a conductive substrate

    NASA Astrophysics Data System (ADS)

    Kumar, S.; Gerhardt, R. A.

    2012-03-01

    The effects of film thickness, electrode size and substrate thickness on the impedance parameters of alternating frequency dielectric measurements of insulating thin films deposited on conductive substrates were studied through parametric finite-element simulations. The quasi-static forms of Maxwell's electromagnetic equations in a time harmonic mode were solved using COMSOL Multiphysics® for several types of 2D models (linear and axisymmetric). The full 2D model deals with a configuration in which the impedance is measured between two surface electrodes on top of a film deposited on a conductive substrate. For the simplified 2D models, the conductive substrate is ignored and the two electrodes are placed on the top and bottom of the film. By comparing the full model and the simplified models, approximations and generalizations are deduced. For highly insulating films, such as the case of insulating SiO2 films on a conducting Si substrate, even the simplified models predict accurate capacitance values at all frequencies. However, the edge effects on the capacitance are found to be significant when the film thickness increases and/or the top electrode contact size decreases. The thickness of the substrate affects predominantly the resistive components of the dielectric response while having no significant effect on the capacitive components. Changing the electrode contact size or the film thickness determines the specific values of the measured resistance or capacitance while the material time constant remains the same, and thus this affects the frequency dependence that is able to be detected. This work highlights the importance of keeping in mind the film thickness and electrode contact size for the correct interpretation of the measured dielectric properties of micro/nanoscale structures that are often investigated using nanoscale capacitance measurements.

  8. Validity of GNRB® arthrometer compared to Telos™ in the assessment of partial anterior cruciate ligament tears.

    PubMed

    Lefevre, N; Bohu, Y; Naouri, J F; Klouche, S; Herman, S

    2014-02-01

    The main goal of this study was to compare the results of the GNRB(®) arthrometer to those of Telos™ in the diagnosis of partial thickness tears of the anterior cruciate ligament (ACL). A prospective study performed January-December 2011 included all patients presenting with a partial or full-thickness ACL tears without ACL reconstruction and with a healthy contralateral knee. Anterior laxity was measured in all patients by the Telos™ and GNRB(®) devices. This series included 139 patients, mean age 30.7 ± 9.3 years. Arthroscopic reconstruction was performed in 109 patients, 97 for complete tears and 12 single bundle reconstructions for partial thickness tears. Conservative treatment was proposed in 30 patients with a partial thickness tear. The correlation between the two devices was evaluated by the Spearman coefficient. The optimal laxity thresholds were determined with ROC curves, and the diagnostic value of the tests was assessed by the area under the curve (AUC). The differential laxities of full and partial thickness tears were significantly different with the two tests. The correlation between the results of laxity measurement with the two devices was fair, with the strongest correlation between Telos™ 250 N and GNRB(®) 250 N (r = 0.46, p = 0.00001). Evaluation of the AUC showed that the informative value of all tests was fair with the best results with the GNRB(®) 250 N: AUC = 0.89 [95 % CI 0.83-0.94]. The optimal differential laxity threshold with the GNRB(®) 250 N was 2.5 mm (Se = 84 %, Sp = 81 %). The diagnostic value of GNRB(®) was better than Telos™ for ACL partial thickness tears.

  9. Improved explanation of human intelligence using cortical features with second order moments and regression.

    PubMed

    Park, Hyunjin; Yang, Jin-ju; Seo, Jongbum; Choi, Yu-yong; Lee, Kun-ho; Lee, Jong-min

    2014-04-01

    Cortical features derived from magnetic resonance imaging (MRI) provide important information to account for human intelligence. Cortical thickness, surface area, sulcal depth, and mean curvature were considered to explain human intelligence. One region of interest (ROI) of a cortical structure consisting of thousands of vertices contained thousands of measurements, and typically, one mean value (first order moment), was used to represent a chosen ROI, which led to a potentially significant loss of information. We proposed a technological improvement to account for human intelligence in which a second moment (variance) in addition to the mean value was adopted to represent a chosen ROI, so that the loss of information would be less severe. Two computed moments for the chosen ROIs were analyzed with partial least squares regression (PLSR). Cortical features for 78 adults were measured and analyzed in conjunction with the full-scale intelligence quotient (FSIQ). Our results showed that 45% of the variance of the FSIQ could be explained using the combination of four cortical features using two moments per chosen ROI. Our results showed improvement over using a mean value for each ROI, which explained 37% of the variance of FSIQ using the same set of cortical measurements. Our results suggest that using additional second order moments is potentially better than using mean values of chosen ROIs for regression analysis to account for human intelligence. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Three-dimensional positioning and structure of chromosomes in a human prophase nucleus

    PubMed Central

    Chen, Bo; Yusuf, Mohammed; Hashimoto, Teruo; Estandarte, Ana Katrina; Thompson, George; Robinson, Ian

    2017-01-01

    The human genetic material is packaged into 46 chromosomes. The structure of chromosomes is known at the lowest level, where the DNA chain is wrapped around a core of eight histone proteins to form nucleosomes. Around a million of these nucleosomes, each about 11 nm in diameter and 6 nm in thickness, are wrapped up into the complex organelle of the chromosome, whose structure is mostly known at the level of visible light microscopy to form a characteristic cross shape in metaphase. However, the higher-order structure of human chromosomes, between a few tens and hundreds of nanometers, has not been well understood. We show a three-dimensional (3D) image of a human prophase nucleus obtained by serial block-face scanning electron microscopy, with 36 of the complete set of 46 chromosomes captured within it. The acquired image allows us to extract quantitative 3D structural information about the nucleus and the preserved, intact individual chromosomes within it, including their positioning and full spatial morphology at a resolution of around 50 nm in three dimensions. The chromosome positions were found, at least partially, to follow the pattern of chromosome territories previously observed only in interphase. The 3D conformation shows parallel, planar alignment of the chromatids, whose occupied volumes are almost fully accounted for by the DNA and known chromosomal proteins. We also propose a potential new method of identifying human chromosomes in three dimensions, on the basis of the measurements of their 3D morphology. PMID:28776025

  11. Topographic variation in redifferentiation capacity of chondrocytes in the adult human knee joint.

    PubMed

    Stenhamre, H; Slynarski, K; Petrén, C; Tallheden, T; Lindahl, A

    2008-11-01

    The aim of this study was to investigate the topographic variation in matrix production and cell density in the adult human knee joint. Additionally, we have examined the redifferentiation potential of chondrocytes expanded in vitro from the different locations. Full thickness cartilage-bone biopsies were harvested from seven separate anatomical locations of healthy knee joints from deceased adult human donors. Chondrocytes were isolated, expanded in vitro and redifferentiated in a pellet mass culture. Biochemical analysis of total collagen, proteoglycans and cellular content as well as histology and immunohistochemistry were performed on biopsies and pellets. In the biochemical analysis of the biopsies, we found lower proteoglycan to collagen (GAG/HP) ratio in the non-weight bearing (NWB) areas compared to the weight bearing (WB) areas. The chondrocytes harvested from different locations in femur showed a significantly better attachment and proliferation ability as well as good post-expansion chondrogenic capacity in pellet mass culture compared with the cells harvested from tibia. These results demonstrate that there are differences in extra cellular content within the adult human knee in respect to GAG/HP ratio. Additionally, the data show that clear differences between chondrocytes harvested from femur and tibia from healthy human knee joints exist and that the differences are not completely abolished during the process of de- and redifferentiation. These findings emphasize the importance of the understanding of topographic variation in articular cartilage biology when approaching new cartilage repair strategies.

  12. Evidence for a cerebral cortical thickness network anti-correlated with amygdalar volume in healthy youths: implications for the neural substrates of emotion regulation.

    PubMed

    Albaugh, Matthew D; Ducharme, Simon; Collins, D Louis; Botteron, Kelly N; Althoff, Robert R; Evans, Alan C; Karama, Sherif; Hudziak, James J

    2013-05-01

    Recent functional connectivity studies have demonstrated that, in resting humans, activity in a dorsally-situated neocortical network is inversely associated with activity in the amygdalae. Similarly, in human neuroimaging studies, aspects of emotion regulation have been associated with increased activity in dorsolateral, dorsomedial, orbital and ventromedial prefrontal regions, as well as concomitant decreases in amygdalar activity. These findings indicate the presence of two countervailing systems in the human brain that are reciprocally related: a dorsally-situated cognitive control network, and a ventrally-situated limbic network. We investigated the extent to which this functional reciprocity between limbic and dorsal neocortical regions is recapitulated from a purely structural standpoint. Specifically, we hypothesized that amygdalar volume would be related to cerebral cortical thickness in cortical regions implicated in aspects of emotion regulation. In 297 typically developing youths (162 females, 135 males; 572 MRIs), the relationship between cortical thickness and amygdalar volume was characterized. Amygdalar volume was found to be inversely associated with thickness in bilateral dorsolateral and dorsomedial prefrontal, inferior parietal, as well as bilateral orbital and ventromedial prefrontal cortices. Our findings are in line with previous work demonstrating that a predominantly dorsally-centered neocortical network is reciprocally related to core limbic structures such as the amygdalae. Future research may benefit from investigating the extent to which such cortical-limbic morphometric relations are qualified by the presence of mood and anxiety psychopathology. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Patient identification using a near-infrared laser scanner

    NASA Astrophysics Data System (ADS)

    Manit, Jirapong; Bremer, Christina; Schweikard, Achim; Ernst, Floris

    2017-03-01

    We propose a new biometric approach where the tissue thickness of a person's forehead is used as a biometric feature. Given that the spatial registration of two 3D laser scans of the same human face usually produces a low error value, the principle of point cloud registration and its error metric can be applied to human classification techniques. However, by only considering the spatial error, it is not possible to reliably verify a person's identity. We propose to use a novel near-infrared laser-based head tracking system to determine an additional feature, the tissue thickness, and include this in the error metric. Using MRI as a ground truth, data from the foreheads of 30 subjects was collected from which a 4D reference point cloud was created for each subject. The measurements from the near-infrared system were registered with all reference point clouds using the ICP algorithm. Afterwards, the spatial and tissue thickness errors were extracted, forming a 2D feature space. For all subjects, the lowest feature distance resulted from the registration of a measurement and the reference point cloud of the same person. The combined registration error features yielded two clusters in the feature space, one from the same subject and another from the other subjects. When only the tissue thickness error was considered, these clusters were less distinct but still present. These findings could help to raise safety standards for head and neck cancer patients and lays the foundation for a future human identification technique.

  14. Modulations of Foot and Ankle Frontal Kinematics for Breaking and Propulsive Movement Characteristics during Side-Step Cutting with Varying Midsole Thicknesses

    PubMed Central

    Lin, Yi-Jia; Lee, Shih-Chi; Chang, Chao-Chin; Liu, Tsung-Han

    2018-01-01

    This study is aimed at determining the effects of midsole thickness on movement characteristic during side cutting movement. Fifteen athletes performed side-step cutting while wearing shoes with varying midsole thicknesses. Temporal-spatial and ground reaction force variables as well as foot and ankle frontal kinematics were used to describe breaking and propulsive movement characteristics and modulation strategies. Regardless of midsole thickness, temporal-spatial variables and breaking and propulsive force during side cutting were statistically unchanged. Significantly greater peaks of ankle inversion and plantarflexion with a thicker sole and greater midtarsal pronation with a thinner sole were observed. Current results demonstrated that hypotheses formed solely based on material testing were insufficient to understand the adaptations in human movement because of the redundancy of the neuromusculoskeletal system. Participants were able to maintain temporal-spatial performance during side cutting while wearing shoes with midsoles of varying thicknesses. Increased pronation for a thinner sole might help reduce the force of impact but might be associated with an increased risk of excessive stress on soft tissue. Increased peak of ankle inversion and plantarflexion for a thicker sole may be unfavorable for the stability of ankle joint. Information provided in human movement testing is crucial for understanding factors associated with movement characteristics and injury and should be considered in the future development of shoe design. PMID:29854000

  15. Psychophysical Measurement of Rod and Cone Thresholds in Stargardt Disease with Full-Field Stimuli

    PubMed Central

    Collison, Frederick T.; Fishman, Gerald A.; McAnany, J. Jason; Zernant, Jana; Allikmets, Rando

    2014-01-01

    Purpose To investigate psychophysical thresholds in Stargardt disease with the full-field stimulus test (FST). Methods Visual acuity (VA), spectral-domain optical coherence tomography (SD-OCT), full-field electroretinogram (ERG), and FST measurements were made in one eye of 24 patients with Stargardt disease. Dark-adapted rod FST thresholds were measured with short-wavelength stimuli, and cone FST thresholds were obtained from the cone plateau phase of dark adaptation using long-wavelength stimuli. Correlation coefficients were calculated for FST thresholds versus macular thickness, VA and ERG amplitudes. Results Stargardt patient FST cone thresholds correlated significantly with VA, macular thickness, and ERG cone-response amplitudes (all P<0.01). The patients’ FST rod thresholds correlated with ERG rod-response amplitudes (P<0.01), but not macular thickness (P=0.05). All Stargardt disease patients with flecks confined to the macula and most of the patients with flecks extending outside of the macula had normal FST thresholds. All patients with extramacular atrophic changes had elevated FST cone thresholds and most had elevated FST rod thresholds. Conclusion FST rod and cone threshold elevation in Stargardt disease patients correlated well with measures of structure and function, as well as ophthalmoscopic retinal appearance. FST appears to be a useful tool for assessing rod and cone function in Stargardt disease. PMID:24695063

  16. Repair of full-thickness articular cartilage defect using stem cell-encapsulated thermogel.

    PubMed

    Zhang, Yanbo; Zhang, Jin; Chang, Fei; Xu, Weiguo; Ding, Jianxun

    2018-07-01

    Cartilage defect repair by hydrogel-based tissue engineering is becoming one of the most potential treatment strategies. In this work, a thermogel of triblock copolymer poly(lactide-co-glycolide)-block-poly(ethylene glycol)-block-poly(lactide-co-glycolide) (PLGA-PEG-PLGA) was prepared as scaffold of bone marrow mesenchymal stem cells (BMMSCs) for repair of full-thickness articular cartilage defect. At first, the copolymer solution showed a reversible sol-gel transition at physiological temperature range, and the mechanical properties of such thermogel were high enough to support the repair of cartilage. Additionally, excellent biodegradability and biocompatibility of the thermogel were demonstrated. By implanting the BMMSC-encapsulated thermogel into the full-thickness articular cartilage defect (5.0 mm in diameter and 4.0 mm in depth) in the rabbit, it was found that the regenerated cartilage integrated well with the surrounding normal cartilage and subchondral bone at 12 weeks post-surgery. The upregulated expression of glycosaminoglycan and type II collagen in the repaired cartilage, and the comparable biomechanical properties with normal cartilage suggested that the cell-encapsulated PLGA-PEG-PLGA thermogel had great potential in serving as the promising scaffold for cartilage regeneration. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Shoulder-specific outcomes 1 year after nontraumatic full-thickness rotator cuff repair: a systematic literature review and meta-analysis.

    PubMed

    Gurnani, Navin; van Deurzen, Derek F P; van den Bekerom, Michel P J

    2017-10-01

    Nontraumatic full-thickness rotator cuff tears are commonly initially treated conservatively. If conservative treatment fails, rotator cuff repair is a viable subsequent option. The objective of the present meta-analysis is to evaluate the shoulder-specific outcomes one year after arthroscopic or mini-open rotator cuff repair of nontraumatic rotator cuff tears. A literature search was conducted in PubMed and EMBASE within the period January 2000 to January 2017. All studies measuring the clinical outcome at 12 months after nontraumatic rotator cuff repair of full-thickness rotator cuff tears were listed. We included 16 randomized controlled trials that met our inclusion criteria with a total of 1.221 shoulders. At 12 months after rotator cuff repair, the mean Constant score had increased 29.5 points; the mean American Shoulder and Elbow Score score increased by 38.6 points; mean Simple Shoulder Test score was 5.6 points; mean University of California Los Angeles score improved by 13.0 points; and finally, mean Visual Analogue Scale score decreased by 4.1 points. Based on this meta-analysis, significant improvements in the shoulder-specific indices are observed 12 months after nontraumatic arthroscopic or mini-open rotator cuff repair.

  18. Laser spot size and beam profile studies for tissue welding applications

    NASA Astrophysics Data System (ADS)

    Fried, Nathaniel M.; Hung, Vincent C.; Walsh, Joseph T., Jr.

    1999-06-01

    We evaluated the effect of changes in laser spot size and beam profile on the thermal denaturation zone produced during laser skin welding. Our objective was to limit heating of the tissue surface, while creating enough thermal denaturation in the deeper layers of the dermis to produce full-thickness welds. Two-cm-long, full-thickness incisions were made on the backs of guinea pigs, in vivo. India ink was used as an absorber. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing approximately 100 ms pulses. Cooling times of 10.0 s between scans were used. Laser spot diameters of 1, 2, 4, and 6 mm were studied, with powers of 1, 4, 16, and 36 W, respectively. The irradiance remained constant at 127 W/cm2. 1, 2, and 4 mm diameter spots produced thermal denaturation to a depth of 570 +/- 100 μm, 970 +/- 210 μm, and 1470 +/- 190 μm, respectively. The 6-mm- diameter spot produced full-thickness welds (1900 μm), but also burns due to the high incident power. Monte Carlo simulations were also conducted, varying the laser spot diameter and beam profile. The simulations verified that an increase in laser spot diameter result in an increase in the penetration depth of radiation into the tissue.

  19. One-stage Reconstruction of Soft Tissue Defects with the Sandwich Technique: Collagen-elastin Dermal Template and Skin Grafts

    PubMed Central

    Wollina, Uwe

    2011-01-01

    Background: A full-thickness soft tissue defect closure often needs complex procedures. The use of dermal templates can be helpful in improving the outcome. Objective: The objective was to evaluate a sandwich technique combining the dermal collagen–elastin matrix with skin grafts in a one-stage procedure. Materials and Methods: Twenty-three patients with 27 wounds were enrolled in this prospective single-centre observational study. The mean age was 74.8 ± 17.2 years. Included were full-thickness defects with exposed bone, cartilage and/ or tendons. The dermal collagen–elastin matrix was applied onto the wound bed accomplished by skin transplants, i.e. ‘sandwich’ transplantation. In six wounds, the transplants were treated with intermittent negative pressure therapy. Results: The size of defects was ≤875 cm2. The use of the dermal template resulted in a complete and stable granulation in 100% of wounds. Seventeen defects showed a complete closure and 19 achieved a complete granulation with an incomplete closure. There was a marked pain relief. No adverse events were noted due to the dermal template usage. Conclusions: Sandwich transplantation with the collagen–elastin matrix is a useful tool when dealing with full-thickness soft tissue defects with exposed bone, cartilage or tendons. PMID:22279382

  20. A novel fibrin-based artificial ovary prototype resembling human ovarian tissue in terms of architecture and rigidity.

    PubMed

    Chiti, Maria Costanza; Dolmans, Marie-Madeleine; Mortiaux, Lucie; Zhuge, Flanco; Ouni, Emna; Shahri, Parinaz Asiabi Kohneh; Van Ruymbeke, Evelyne; Champagne, Sophie-Demoustier; Donnez, Jacques; Amorim, Christiani Andrade

    2018-01-01

    The aim of this study is to optimize fibrin matrix composition in order to mimic human ovarian tissue architecture for human ovarian follicle encapsulation and grafting. Ultrastructure of fresh human ovarian cortex in age-related women (n = 3) and different fibrin formulations (F12.5/T1, F30/T50, F50/T50, F75/T75), rheology of fibrin matrices and histology of isolated and encapsulated human ovarian follicles in these matrices. Fresh human ovarian cortex showed a highly fibrous and structurally inhomogeneous architecture in three age-related patients, but the mean ± SD of fiber thickness (61.3 to 72.4 nm) was comparable between patients. When the fiber thickness of four different fibrin formulations was compared with human ovarian cortex, F50/T50 and F75/T75 showed similar fiber diameters to native tissue, while F12.5/T1 was significantly different (p value < 0.01). In addition, increased concentrations of fibrin exhibited enhanced storage modulus with F50/T50, resembling physiological ovarian rigidity. Excluding F12.5/T1 from further analysis, only three remaining fibrin matrices (F30/T50, F50/T50, F75/T75) were histologically investigated. For this, frozen-thawed fragments of human ovarian tissue collected from 22 patients were used to isolate ovarian follicles and encapsulate them in the three fibrin formulations. All three yielded similar follicle recovery and loss rates soon after encapsulation. Therefore, based on fiber thickness, porosity, and rigidity, we selected F50/T50 as the fibrin formulation that best mimics native tissue. Of all the different fibrin matrix concentrations tested, F50/T50 emerged as the combination of choice in terms of ultrastructure and rigidity, most closely resembling human ovarian cortex.

  1. Interdigitated Color- and Disparity-Selective Columns within Human Visual Cortical Areas V2 and V3

    PubMed Central

    Polimeni, Jonathan R.; Tootell, Roger B.H.

    2016-01-01

    In nonhuman primates (NHPs), secondary visual cortex (V2) is composed of repeating columnar stripes, which are evident in histological variations of cytochrome oxidase (CO) levels. Distinctive “thin” and “thick” stripes of dark CO staining reportedly respond selectively to stimulus variations in color and binocular disparity, respectively. Here, we first tested whether similar color-selective or disparity-selective stripes exist in human V2. If so, available evidence predicts that such stripes should (1) radiate “outward” from the V1–V2 border, (2) interdigitate, (3) differ from each other in both thickness and length, (4) be spaced ∼3.5–4 mm apart (center-to-center), and, perhaps, (5) have segregated functional connections. Second, we tested whether analogous segregated columns exist in a “next-higher” tier area, V3. To answer these questions, we used high-resolution fMRI (1 × 1 × 1 mm3) at high field (7 T), presenting color-selective or disparity-selective stimuli, plus extensive signal averaging across multiple scan sessions and cortical surface-based analysis. All hypotheses were confirmed. V2 stripes and V3 columns were reliably localized in all subjects. The two stripe/column types were largely interdigitated (e.g., nonoverlapping) in both V2 and V3. Color-selective stripes differed from disparity-selective stripes in both width (thickness) and length. Analysis of resting-state functional connections (eyes closed) showed a stronger correlation between functionally alike (compared with functionally unlike) stripes/columns in V2 and V3. These results revealed a fine-scale segregation of color-selective or disparity-selective streams within human areas V2 and V3. Together with prior evidence from NHPs, this suggests that two parallel processing streams extend from visual subcortical regions through V1, V2, and V3. SIGNIFICANCE STATEMENT In current textbooks and reviews, diagrams of cortical visual processing highlight two distinct neural-processing streams within the first and second cortical areas in monkeys. Two major streams consist of segregated cortical columns that are selectively activated by either color or ocular interactions. Because such cortical columns are so small, they were not revealed previously by conventional imaging techniques in humans. Here we demonstrate that such segregated columnar systems exist in humans. We find that, in humans, color versus binocular disparity columns extend one full area further, into the third visual area. Our approach can be extended to reveal and study additional types of columns in human cortex, perhaps including columns underlying more cognitive functions. PMID:26865609

  2. Transtendon, Double-Row, Transosseous-Equivalent Arthroscopic Repair of Partial-Thickness, Articular-Surface Rotator Cuff Tears

    PubMed Central

    Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.

    2014-01-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606

  3. Transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears.

    PubMed

    Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D

    2014-10-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.

  4. Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.

    PubMed

    Moilanen, Petro; Zhao, Zuomin; Karppinen, Pasi; Karppinen, Timo; Kilappa, Vantte; Pirhonen, Jalmari; Myllylä, Risto; Haeggström, Edward; Timonen, Jussi

    2014-03-01

    Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the same side of the coated phantom with a heterodyne interferometer. The FFGW was detected at 30-kHz frequency. Fitting the FFGW phase velocity by the FLC(1,1) tube mode provided an accurate (9.5 ± 4.0%) wall thickness estimate. Ultrasonic in vivo characterization of cortical bone thickness may thus become possible. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. In vivo skin effects of a dimethylaminoethanol (DMAE) based formulation.

    PubMed

    Tadini, K A; Campos, P M B G Maia

    2009-12-01

    Dimethylaminoethanol (DMAE) has been used in anti-aging formulations but few scientifically based data address its efficacy. The aim of this study was to evaluate the effects of DMAE-based formulations on hairless mice and human skin. Formulations containing with or without DMAE were applied to the dorsum of hairless mice. Histopathological and histometric evaluations were carried out after seven days. Formulations were also applied to the ventral forearm and the lateral periocular area of human volunteers. Stratum corneum water content and skin mechanical properties were analyzed using Corneometer and Cutometer, before and after a single and repeated application. Histometric evaluations showed that formulations with or without DMAE increased the viable epidermis thickness, but only the DMAE-supplemented formulation led to increased dermal thickness. DMAE also induced increase in collagen fiber thickness, which was observed in the histopathological study. After the single and the 8-week period application on human skin, formulations with and without DMAE enhanced the stratum corneum water content in the forearm skin. Mechanical properties were not significantly modified. So, we can suggest that DMAE action is related to its effects on the dermis as observed in the histopathological and histometric studies and showed hydration effects on skin.

  6. The Superior Labrum, Anterior-to-Posterior ’SLAP’ Lesion

    DTIC Science & Technology

    2006-10-01

    and optimize surgical outcomes. Shoulder arthroscopy is the mainstay of diagnosis and treatment for most patients with SLAP lesions (1). A...complete diagnostic arthroscopy should include an inspection of the rotator cuff for associated partial thickness or full- thickness tears and inspection of...Karzel RP, Del Pizzo, W, et al: SLAP lesions of the shoulder. Arthroscopy 1990; 6:274-279. 2 Sanders TG, Morrison WB, and Miller, MD: Imaging

  7. Saksenaea erythrospora Infection Following Combat Trauma

    DTIC Science & Technology

    2011-10-01

    partial-thickness and full-thick- ness burns affecting his head, arms, and legs. No evidence of significant smoke inhalation injury was noted on...extract-water culture at 35°C. The water culture remained sterile after 4 weeks; however, a few fruiting structures were seen on the CZA plate and the...weeks of incubation at 25°C. (B) Fruiting structure of S. erythrospora depicting lateral rhizoids; a brown, straight, encrusted sporangiophore; the

  8. Cleaning with a wet sterile gauze significantly reduces contamination of sutures, instruments, and surgical gloves in an ex-vivo pelvic flexure enterotomy model in horses.

    PubMed

    Giusto, Gessica; Tramuta, Clara; Caramello, Vittorio; Comino, Francesco; Nebbia, Patrizia; Robino, Patrizia; Singer, Ellen; Grego, Elena; Gandini, Marco

    2017-01-01

    The objective of this study was to investigate whether cleaning surgical materials used to close pelvic flexure enterotomies with a wet sterile gauze will reduce contamination and whether the use of a full thickness appositional suture pattern (F) or a partial thickness inverting (or Cushing) suture pattern (C) would make a difference in the level of contamination. Large colon specimens were assigned to group F or C and divided into subgroups N and G. In group G, a wet sterile gauze was passed over the suture material, another over the instruments, and another over the gloves. In group N, no treatment was applied. The bacterial concentration was measured by optical density (OD) at 24 h. The OD of subgroup CG was lower than that of subgroup CN ( P = 0.019). The OD of subgroup FG was lower than that of subgroup FN ( P = 0.02). The OD of subgroups CG, CN, FG, and FN was lower than that of the negative control ( P < 0.003, P < 0.001, P < 0.001, and P < 0.00). The use of a sterile wet gauze significantly reduced contamination of suture materials. A partial thickness inverting suture pattern did not produce less contamination than a full thickness appositional suture pattern.

  9. Additive-free thick graphene film as an anode material for flexible lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Rana, Kuldeep; Kim, Seong Dae; Ahn, Jong-Hyun

    2015-04-01

    This work demonstrates a simple route to develop mechanically flexible electrodes for Li-ion batteries (LIBs) that are usable as lightweight effective conducting networks for both cathodes and anodes. Removing electrochemically dead elements, such as binders, conducting agents and metallic current collectors, from the battery components will allow remarkable progress in this area. To investigate the feasibility of using thick, additive-free graphene films as anodes for flexible LIBs, we have synthesized and tested thick, additive-free, freestanding graphene films as anodes, first in a coin cell and further in a flexible full cell. As an anode material in a half cell, it showed a discharge capacity of about 350 mA h g-1 and maintained nearly this capacity over 50 cycles at various current rates. This film was also tested as an anode material in a full cell with a LiCoO2 cathode and showed good electrochemical performance. Because the graphene-based flexible film showed good performance in half- and full coin cells, we used this film as a flexible anode for flexible LIBs. No conducting agent or binder was used in the anode side, which helped in realizing the flexible LIBs. Using this, we demonstrate a thin, lightweight and flexible lithium ion battery with good electrochemical performance in both its flat and bent states.This work demonstrates a simple route to develop mechanically flexible electrodes for Li-ion batteries (LIBs) that are usable as lightweight effective conducting networks for both cathodes and anodes. Removing electrochemically dead elements, such as binders, conducting agents and metallic current collectors, from the battery components will allow remarkable progress in this area. To investigate the feasibility of using thick, additive-free graphene films as anodes for flexible LIBs, we have synthesized and tested thick, additive-free, freestanding graphene films as anodes, first in a coin cell and further in a flexible full cell. As an anode material in a half cell, it showed a discharge capacity of about 350 mA h g-1 and maintained nearly this capacity over 50 cycles at various current rates. This film was also tested as an anode material in a full cell with a LiCoO2 cathode and showed good electrochemical performance. Because the graphene-based flexible film showed good performance in half- and full coin cells, we used this film as a flexible anode for flexible LIBs. No conducting agent or binder was used in the anode side, which helped in realizing the flexible LIBs. Using this, we demonstrate a thin, lightweight and flexible lithium ion battery with good electrochemical performance in both its flat and bent states. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr06082b

  10. Effect of human milk as a treatment for dry eye syndrome in a mouse model

    PubMed Central

    Diego, Jose L.; Bidikov, Luke; Pedler, Michelle G.; Kennedy, Jeffrey B.; Quiroz-Mercado, Hugo; Gregory, Darren G.; Petrash, J. Mark

    2016-01-01

    Purpose Dry eye syndrome (DES) affects millions of people worldwide. Homeopathic remedies to treat a wide variety of ocular diseases have previously been documented in the literature, but little systematic work has been performed to validate the remedies’ efficacy using accepted laboratory models of disease. The purpose of this study was to evaluate the efficacy of human milk and nopal cactus (prickly pear), two widely used homeopathic remedies, as agents to reduce pathological markers of DES. Methods The previously described benzalkonium chloride (BAK) dry eye mouse model was used to study the efficacy of human milk and nopal cactus (prickly pear). BAK (0.2%) was applied to the mouse ocular surface twice daily to induce dry eye pathology. Fluorescein staining was used to verify that the animals had characteristic signs of DES. After induction of DES, the animals were treated with human milk (whole and fat-reduced), nopal, nopal extract derivatives, or cyclosporine four times daily for 7 days. Punctate staining and preservation of corneal epithelial thickness, measured histologically at the end of treatment, were used as indices of therapeutic efficacy. Results Treatment with BAK reduced the mean corneal epithelial thickness from 36.77±0.64 μm in the control mice to 21.29±3.2 μm. Reduction in corneal epithelial thickness was largely prevented by administration of whole milk (33.2±2.5 μm) or fat-reduced milk (36.1±1.58 μm), outcomes that were similar to treatment with cyclosporine (38.52±2.47 μm), a standard in current dry eye therapy. In contrast, crude or filtered nopal extracts were ineffective at preventing BAK-induced loss of corneal epithelial thickness (24.76±1.78 μm and 27.99±2.75 μm, respectively), as were solvents used in the extraction of nopal materials (26.53±1.46 μm for ethyl acetate, 21.59±5.87 μm for methanol). Epithelial damage, as reflected in the punctate scores, decreased over 4 days of treatment with whole and fat-reduced milk but continued to increase in eyes treated with nopal-derived materials. Conclusions Whole and fat-reduced human milk showed promising effects in the prevention of BAK-induced loss of corneal epithelial thickness and epithelial damage in this mouse model. Further studies are required to determine whether human milk may be safely used to treat dry eye in patients. PMID:27667918

  11. Effect of human milk as a treatment for dry eye syndrome in a mouse model.

    PubMed

    Diego, Jose L; Bidikov, Luke; Pedler, Michelle G; Kennedy, Jeffrey B; Quiroz-Mercado, Hugo; Gregory, Darren G; Petrash, J Mark; McCourt, Emily A

    Dry eye syndrome (DES) affects millions of people worldwide. Homeopathic remedies to treat a wide variety of ocular diseases have previously been documented in the literature, but little systematic work has been performed to validate the remedies' efficacy using accepted laboratory models of disease. The purpose of this study was to evaluate the efficacy of human milk and nopal cactus (prickly pear), two widely used homeopathic remedies, as agents to reduce pathological markers of DES. The previously described benzalkonium chloride (BAK) dry eye mouse model was used to study the efficacy of human milk and nopal cactus (prickly pear). BAK (0.2%) was applied to the mouse ocular surface twice daily to induce dry eye pathology. Fluorescein staining was used to verify that the animals had characteristic signs of DES. After induction of DES, the animals were treated with human milk (whole and fat-reduced), nopal, nopal extract derivatives, or cyclosporine four times daily for 7 days. Punctate staining and preservation of corneal epithelial thickness, measured histologically at the end of treatment, were used as indices of therapeutic efficacy. Treatment with BAK reduced the mean corneal epithelial thickness from 36.77±0.64 μm in the control mice to 21.29±3.2 μm. Reduction in corneal epithelial thickness was largely prevented by administration of whole milk (33.2±2.5 μm) or fat-reduced milk (36.1±1.58 μm), outcomes that were similar to treatment with cyclosporine (38.52±2.47 μm), a standard in current dry eye therapy. In contrast, crude or filtered nopal extracts were ineffective at preventing BAK-induced loss of corneal epithelial thickness (24.76±1.78 μm and 27.99±2.75 μm, respectively), as were solvents used in the extraction of nopal materials (26.53±1.46 μm for ethyl acetate, 21.59±5.87 μm for methanol). Epithelial damage, as reflected in the punctate scores, decreased over 4 days of treatment with whole and fat-reduced milk but continued to increase in eyes treated with nopal-derived materials. Whole and fat-reduced human milk showed promising effects in the prevention of BAK-induced loss of corneal epithelial thickness and epithelial damage in this mouse model. Further studies are required to determine whether human milk may be safely used to treat dry eye in patients.

  12. Corneal thickness: measurement and implications.

    PubMed

    Ehlers, Niels; Hjortdal, Jesper

    2004-03-01

    The thickness of the cornea was reported in more than 100-year-old textbooks on physiological optics (Helmholtz, Gullstrand). Physiological interest was revived in the 1950s by David Maurice, and over the next 50 years, this 'simple' biological parameter has been studied extensively. Several techniques for its measurement have been described and physiological and clinical significance have been studied. In this review, the different methods and techniques of measurement are briefly presented (optical, ultrasound). While the corneal thickness of many animals are the same over a considerable part of the surface, in the human cornea anterior and posterior curvature are not concentric giving rise to a problem of definition. Based on this the precision and accuracy of determining the central corneal thickness are discussed. Changes in corneal thickness reflects changes in function of the boundary layers, in particular the endothelial barrier. The absolute value of thickness is of importance for the estimation of IOP but also in diagnosis of corneal and systemic disorders. Finally it is discussed to what extent the thickness is a biometric parameter of significance, e.g. in the progression of myopia or in the development of retinal detachment.

  13. Imaging the distribution of sodium dodecyl sulfate in skin by confocal Raman and infrared microspectroscopy.

    PubMed

    Mao, G; Flach, C R; Mendelsohn, R; Walters, R M

    2012-08-01

    To image SDS distribution across different skin regions, to compare the permeability difference between porcine and human skin, and to evaluate the interaction between SDS and skin. Full thickness porcine and human skin was treated with acyl chain perdeuterated SDS (SDS-d(25)) at room temperature and at 34 °C for 3, 24 and 40 h. SDS distribution in skin was monitored by confocal Raman and IR microspectroscopic imaging. Permeation profiles of SDS-d(25) in skin were derived from the band intensities of the CD(2) stretching vibrations. The interaction between SDS and skin was monitored through the CH(2) and CD(2) stretching frequencies and the Amide I and II spectral region. SDS-d(25) penetrates both porcine and human skin in a time and temperature-dependent manner, with slightly higher permeability through the stratum corneum (SC) in porcine skin. When SDS permeates into the SC, its chains are more ordered compared to SDS micelles. The secondary structure of keratin in the SC is not affected by SDS-d(25). The spatial distribution of SDS-d(25) in skin was obtained for the first time. Infrared microscopic imaging provides unique opportunities to measure concentration profiles of exogenous materials in skin and offers insights to interaction between permeants and skin.

  14. Bioactivity of freeze-dried platelet-rich plasma in an adsorbed form on a biodegradable polymer material.

    PubMed

    Nakajima, Yu; Kawase, Tomoyuki; Kobayashi, Mito; Okuda, Kazuhiro; Wolff, Larry F; Yoshie, Hiromasa

    2012-01-01

    Owing to the necessity for the immediate preparation from patients' blood, autologous platelet-rich plasma (PRP) limits its clinical applicability. To address this concern and respond to emergency care and other unpredictable uses, we have developed a freeze-dried PRP in an adsorbed form on a biodegradable polymer material (Polyglactin 910). On the polymer filaments of PRP mesh, which was prepared by coating the polymer mesh with human fresh PRP and subsequent freeze-drying, platelets were incorporated, and related growth factors were preserved at high levels. This new PRP mesh preparation significantly and reproducibly stimulated the proliferation of human periodontal ligament cells in vitro and neovascularization in a chorioallantoic membrane assay. A full-thickness skin defect model in a diabetic mouse demonstrated the PRP mesh, although prepared from human blood, substantially facilitated angiogenesis, granulation tissue formation, and re-epithelialization without inducing severe inflammation in vivo. These data demonstrate that our new PRP mesh preparation functions as a bioactive material to facilitate tissue repair/regeneration. Therefore, we suggest that this bioactive material, composed of allogeneic PRP, could be clinically used as a promising alternative in emergency care or at times when autologous PRP is not prepared immediately before application.

  15. Topical penetration of commercial salicylate esters and salts using human isolated skin and clinical microdialysis studies

    PubMed Central

    Cross, Sheree E; Anderson, Chris; Roberts, Michael S

    1998-01-01

    Aims The penetration of active ingredients from topically applied anti-inflammatory pharmaceutical products into tissues below the skin is the basis of their therapeutic efficacy. There is still controversy as to whether these agents are capable of direct penetration by diffusion through the tissues or whether redistribution in the systemic circulation is responsible for their tissue deposition below the application site. Methods The extent of direct penetration of salicylate from commercial ester and salt formulations into the dermal and subcutaneous tissue of human volunteers was determined using the technique of cutaneous microdialysis. We also examined differences in the extent of hydrolysis of the methylester of salicylate applied topically in human volunteers and in vitro skin diffusion cells using full-thickness skin and epidermal membranes. Results The present study showed that whilst significant levels of salicylate could be detected in the dermis and subcutaneous tissue of volunteers treated with the methylsalicylate formulation, negligible levels of salicylate were seen following application of the triethanolamine salicylate formulation. The tissue levels of salicylate from the methylsalicylate formulation were approx. 30-fold higher than the plasma concentrations. Conclusion The absorption and tissue concentration profiles for the commercial methylsalicylate formulation are indicative of direct tissue penetration and not solely redistribution by the systemic blood supply. PMID:9690946

  16. Cell fiber-based three-dimensional culture system for highly efficient expansion of human induced pluripotent stem cells.

    PubMed

    Ikeda, Kazuhiro; Nagata, Shogo; Okitsu, Teru; Takeuchi, Shoji

    2017-06-06

    Human pluripotent stem cells are a potentially powerful cellular resource for application in regenerative medicine. Because such applications require large numbers of human pluripotent stem cell-derived cells, a scalable culture system of human pluripotent stem cell needs to be developed. Several suspension culture systems for human pluripotent stem cell expansion exist; however, it is difficult to control the thickness of cell aggregations in these systems, leading to increased cell death likely caused by limited diffusion of gases and nutrients into the aggregations. Here, we describe a scalable culture system using the cell fiber technology for the expansion of human induced pluripotent stem (iPS) cells. The cells were encapsulated and cultured within the core region of core-shell hydrogel microfibers, resulting in the formation of rod-shaped or fiber-shaped cell aggregations with sustained thickness and high viability. By encapsulating the cells with type I collagen, we demonstrated a long-term culture of the cells by serial passaging at a high expansion rate (14-fold in four days) while retaining its pluripotency. Therefore, our culture system could be used for large-scale expansion of human pluripotent stem cells for use in regenerative medicine.

  17. Importance of Thickness in Human Cardiomyocyte Network for Effective Electrophysiological Stimulation Using On-Chip Extracellular Microelectrodes

    NASA Astrophysics Data System (ADS)

    Hamada, Tomoyo; Nomura, Fumimasa; Kaneko, Tomoyuki; Yasuda, Kenji

    2012-06-01

    We have developed a three-dimensionally controlled in vitro human cardiomyocyte network assay for the measurements of drug-induced conductivity changes and the appearance of fatal arrhythmia such as ventricular tachycardia/fibrillation for more precise in vitro predictive cardiotoxicity. To construct an artificial conductance propagation model of a human cardiomyocyte network, first, we examined the cell concentration dependence of the cell network heights and found the existence of a height limit of cell networks, which was double-layer height, whereas the cardiomyocytes were effectively and homogeneously cultivated within the microchamber maintaining their spatial distribution constant and their electrophysiological conductance and propagation were successfully recorded using a microelectrode array set on the bottom of the microchamber. The pacing ability of a cardiomyocyte's electrophysiological response has been evaluated using microelectrode extracellular stimulation, and the stimulation for pacing also successfully regulated the beating frequencies of two-layered cardiomyocyte networks, whereas monolayered cardiomyocyte networks were hardly stimulated by the external electrodes using the two-layered cardiomyocyte stimulation condition. The stability of the lined-up shape of human cardiomyocytes within the rectangularly arranged agarose microchambers was limited for a two-layered cardiomyocyte network because their stronger force generation shrunk those cells after peeling off the substrate. The results indicate the importance of fabrication technology of thickness control of cellular networks for effective extracellular stimulation and the potential concerning thick cardiomyocyte networks for long-term cultivation.

  18. Injection of human mesenchymal stem cells improves healing of scarred vocal folds: analysis using a xenograft model.

    PubMed

    Svensson, Bengt; Nagubothu, R Srinivasa; Cedervall, Jessica; Le Blanc, Katarina; Ahrlund-Richter, Lars; Tolf, Anna; Hertegård, Stellan

    2010-07-01

    The aims were to analyze if improved histological and viscoelastic properties seen after injection of human mesenchymal stem cells (hMSCs) in scarred vocal folds (VFs) of rabbits are sustainable and if the injected hMSCs survive 3 months in the VFs. Experimental xenograft model. Eighteen VFs of 11 New Zealand white rabbits were scarred by a bilateral localized resection. After 3 months the animals were sacrificed. Twelve VFs were dissected and stained for histology, lamina propria thickness, and relative collagen type I analyses. The hMSCs survival was analyzed using a human DNA-specific reference probe, that is, fluorescence in situ hybridization staining. Viscoelasticity, measured as the dynamic viscosity and elastic modulus, was analyzed in a parallel-plate rheometer for 10 VFs. The dynamic viscosity and elastic modulus of hMSC-treated VFs were similar to that of normal controls and significantly improved compared to untreated controls (P < .05). A reduction in lamina propria thickness and relative collagen type 1 content were also shown for the hMSC-treated VFs compared to the untreated VFs (P < .05). The histological pictures corresponded well to the viscoelastic results. No hMSCs survived. Human mesenchymal stem cells injected into a scarred vocal fold of rabbit enhance healing of the vocal fold with reduced lamina propria thickness and collagen type I content and restore the viscoelastic function.

  19. Sclera-Choroid-RPE Transport of Eight β-Blockers in Human, Bovine, Porcine, Rabbit, and Rat Models

    PubMed Central

    Kadam, Rajendra S.; Cheruvu, Narayan P. S.; Edelhauser, Henry F.

    2011-01-01

    Purpose. To determine the influence of drug lipophilicity, ocular pigmentation, and species differences on transscleral solute transport. Methods. The transport of eight β-blockers across excised sclera/sclera-choroid-RPE (SCRPE) of albino rabbit, pigmented rabbit, human, porcine, and bovine eyes was determined over 6 hours. The ex vivo transscleral β-blocker transport to the vitreous at the end of 6 hours was determined in euthanatized, pigmented Brown Norway rats. The thicknesses of the sclera and SCRPE and the melanin content in choroid-RPE (CRPE) were measured to determine whether species differences in drug transport can be explained on this basis. Results. Solute lipophilicity inversely correlated with the SCRPE cumulative percentage of transport in all species (R2 ≥ 0.80). The CRPE impeded the SCRPE transport of all β-blockers (51%–64% resistance in the rabbits; 84%–99.8% in the bovine and porcine eyes) more than the sclera, with the impedance increasing with lipophilicity. SCRPE transport followed the trend albino rabbit > pigmented rabbit > human > porcine > bovine, and a cross-species comparison showed good Spearman's rho correlation (R2 ≥ 0.85). Bovine (R2 = 0.84), porcine (R2 = 0.84), and human (R2 = 0.71) SCRPE transport was more predictive than that in the rabbit models (R2 = 0.60–0.61) of transscleral solute transport to the vitreous in rats. The CRPE concentrations were higher in pigmented rabbits than in albino rabbits. The melanin content of the CRPE exhibited the trend albino rabbit ≪ pigmented rabbit < porcine ∼ bovine < rat. Normalization to scleral thickness abolished the species differences in scleral transport. Normalization to SCRPE thickness and melanin content significantly reduced species differences in SCRPE transport. Conclusions. Owing to the presence of pigment and drug binding, choroid-RPE is the principal barrier to transscleral β-blocker transport, with the barrier being more significant for lipophilic β-blockers. Although different in magnitude between species, sclera/SCRPE transport can be correlated between species. Tissue thickness accounts for the species differences in scleral transport. Differences in tissue thickness and melanin content largely account for the species differences in SCRPE transport. PMID:21282583

  20. Dynamic interfacial properties of human tear-lipid films and their interactions with model-tear proteins in vitro.

    PubMed

    Svitova, Tatyana F; Lin, Meng C

    2016-07-01

    This review summarizes the current state of knowledge regarding interfacial properties of very complex biological colloids, specifically, human meibum and tear lipids, and their interactions with proteins similar to the proteins found in aqueous part of human tears. Tear lipids spread as thin films over the surface of tear-film aqueous and play crucial roles in tear-film stability and overall ocular-surface health. The vast majority of papers published to date report interfacial properties of meibum-lipid monolayers spread on various aqueous sub-phases, often containing model proteins, in Langmuir trough. However, it is well established that natural human ocular tear lipids exist as multilayered films with a thickness between 30 and 100nm, that is very much disparate from 1 to 2nm thick meibum monolayers. We employed sessile-bubble tensiometry to study the dynamic interfacial and rheological properties of reconstituted multilayered human tear-lipid films. Small amounts (0.5-1μg) of human tear lipids were deposited on an air-bubble surface to produce tear-lipid films in thickness range 30-100nm corresponding to ocular lipid films. Thus, we were able to overcome major Langmuir-trough method limitations because ocular tear lipids can be safely harvested only in minute, sub-milligram quantities, insufficient for Langmuir through studies. Sessile-bubble method is demonstrated to be a versatile tool for assessing conventional synthetic surfactants adsorption/desorption dynamics at an air-aqueous solution interface. (Svitova T., Weatherbee M., Radke C.J. Dynamics of surfactant sorption at the air/water interface: continuous-flow tensiometry. J. Colloid Interf. Sci. 2003;261:1170-179). The augmented flow-sessile-bubble setup, with step-strain relaxation module for dynamic interfacial rheological properties and high-precision syringe pump to generate larger and slow interfacial area expansions-contractions, was developed and employed in our studies. We established that this method is uniquely suitable for examination of multilayered lipid-film interfacial properties. Recently it was compellingly proven that chemical composition of human tear lipids extracted from whole tears is substantially different from that of meibum lipids. To be exact, healthy human tear lipids contain 8-16% of polar lipids, similar to lung lipids, and they are mostly double-tailed phospholipids, with C16 and longer alkyl chains. Rationally, one would assume that the results obtained for meibum lipids, devoid of surface-active components such as phospholipids, and, above all, in a form of monolayers, are not pertinent or useful for elucidating behavior and stability of an averaged 60-nm thick ocular tear-lipid films in vivo. The advantage of sessile-bubble technique, specifically, using a small amount of lipids required to attain multilayered films, unlocks the prospect of evaluating and comparing the interfacial properties of human tear lipids collected from a single individual, typically 100-150μg. This is in sharp contrast with several milligrams of lipids that would be required to build equally thick films for Langmuir-trough experiments. The results of our studies provided in-depth understanding of the mechanisms responsible for properties and stability of human tear-lipid films in vivo. Here we summarize recent publications and our latest findings regarding human tear-lipid interfacial properties, their chemical composition, and their interaction with model proteins mimicking the proteins found in human tear-aqueous phase. Published by Elsevier B.V.

  1. Integra as a Dermal Replacement in a Meshed Composite Skin Graft in a Rat Model: A One-Step Operative Procedure

    DTIC Science & Technology

    2002-01-01

    skin graft (MCSG) using Integra as a dermal template for a meshed split thickness autograft was developed in rats. The silicon layer of Integra was removed, the resulting dermal analogue was meshed (1:1.5), expanded, and placed on excised full thickness wound and covered with a meshed (1:1.5 or 1:6) split thickness autograft. Grafted wounds were dressed with BioBrane, Vaseline gauze, silver-impregnated nylon, or silver-nylon and direct current (SNDC). At scheduled intervals up to 3 months postgrafting, wounds were examined for epithelialization, collagen deposition and

  2. Retinal Tissue Thickness is Reduced in Diabetic Peripheral Neuropathy.

    PubMed

    Srinivasan, Sangeetha; Pritchard, Nicola; Vagenas, Dimitrios; Edwards, Katie; Sampson, Geoff P; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan

    2016-10-01

    To investigate the relationship between diabetic peripheral neuropathy (DPN) and retinal tissue thickness. Full retinal thickness in the central retinal, parafoveal, and perifoveal zones and thickness of the ganglion cell complex and retinal nerve fiber layer (RNFL) were assessed in 193 individuals (84 with type 1 diabetes, 67 with type 2 diabetes, and 42 healthy controls) using spectral domain optical coherence tomography. Among those with diabetes, 44 had neuropathy defined using a modified neuropathy disability score recorded on a 0-10 scale. Multiple regression analysis was performed to investigate the relationship between diabetic neuropathy and retinal tissue thickness, adjusted for the presence of diabetic retinopathy (DR), age, sex, duration of diabetes, and HbA 1c levels. In individuals with diabetes, perifoveal thickness was inversely related to the severity of neuropathy (p < 0.05), when adjusted for age, sex, duration of diabetes, and HbA 1c levels. DR was associated with reduced thickness in parafovea (p < 0.01). The RNFL was thinner in individuals with greater degrees of neuropathy (p < 0.04). DPN is associated with structural compromise involving several retinal layers. This compromise may represent a threat to visual integrity and therefore warrants examination of functional correlates.

  3. Microscopic image processing systems for measuring nonuniform film thickness profiles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, A.H.; Plawsky, J.L.; DasGupta, S.

    1994-01-01

    In very thin liquid films. transport processes are controlled by the temperature and the interfacial intermolecular force field which is a function of the film thickness profile and interfacial properties. The film thickness profile and interfacial properties can be measured most efficiently using a microscopic image processing system. IPS, to record the intensity pattern of the reflected light from the film. There are two types of IPS: an image analyzing interferometer (IAI) and/or an image scanning ellipsometer (ISE). The ISE is a novel technique to measure the two dimensional thickness profile of a nonuniform, thin film, from 1 nm upmore » to several {mu}m, in a steady state as well as in a transient state. It is a full field imaging technique which can study every point on the surface simultaneously with high spatial resolution and thickness sensitivity, i.e., it can measure and map the 2-D film thickness profile. Using the ISE, the transient thickness profile of a draining thin liquid film was measured and modeled. The interfacial conditions were determined in situ by measuring the Hamaker constant. The ISE and IAI systems are compared.« less

  4. The use of short spreader grafts in rhinoplasty for patients with thick nasal skin.

    PubMed

    Grigoryants, Vladimir; Baroni, Arpa

    2013-06-01

    Thick nasal skin presents a challenge in rhinoplasty. Conventional spreader grafts in patients with thick nasal skin may result in an undesirable widening of the lower half of the nose where the nasal skin is thick. The use of short spreader grafts was evaluated in patients with thick nasal skin. For this study, 32 patients underwent closed rhinoplasty in which short spreader grafts were used. The spreader graft was 1 to 2 cm long and extended only to the transition of thin and thick nasal skin. The patients were followed for more than 1 year postoperatively. Aesthetic improvement was observed in all the patients. Nasal airway patency was improved or maintained in 94 % of the patients. Short spreader grafts effectively restore or maintain the internal nasal valve area after dorsal hump reduction while allowing for more aggressive narrowing of the lower part of the nose where nasal skin is thick. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  5. Influence of Flap Thickness on Nipple Projection After Nipple Reconstruction Using a Modified Star Flap.

    PubMed

    Ishii, Naohiro; Ando, Jiro; Harao, Michiko; Takemae, Masaru; Kishi, Kazuo

    2018-05-07

    In nipple reconstruction, the width, length, and thickness of modified star flaps are concerns for long-term reconstructed nipple projection. However, the flap's projection has not been analyzed, based on its thickness. The aim of the present study was to investigate how flap thickness in a modified star flap influences the resulting reconstructed nipple and achieves an appropriate flap width in design. Sixty-three patients who underwent nipple reconstruction using a modified star flap following implant-based breast reconstruction between August 2014 and July 2016 were included in this case-controlled study. The length of laterally diverging flaps was 1.5 times their width. The thickness of each flap was measured using ultrasonography, and the average thickness was defined as the flap thickness. We investigated the correlation between the resulting reconstructed nipple and flap thickness, and the difference of the change in the reconstructed nipple projection after using a thin or thick flap. The average flap thickness was 3.8 ± 1.7 (range 2.5-6.0) mm. There was a significant, linear correlation between the flap thickness and resulting reconstructed nipple projection (β = 0.853, p < 0.01). Furthermore, the difference between the thin and thick flaps in the resulting reconstructed nipple projection was significant (p < 0.01). Measuring the flap thickness preoperatively may allow surgeons to achieve an appropriate flap width; otherwise, alternative methods for higher projection might be used. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  6. Finite-element analysis of vibrational modes in piezoelectric ceramic disks.

    PubMed

    Kunkel, H A; Locke, S; Pikeroen, B

    1990-01-01

    The natural vibrational modes of axially symmetric piezoelectric ceramic disks have been calculated by the finite-element method. The disks are of the type used as active elements in compressional wave ultrasonic transducers, and are electrically polarized in thickness with full electrodes on the disk's major faces. To optimize disk geometry for ultrasonic transducer application, the dependence of the vibrational modes on the disk diameter-to-thickness ratio for ratios from 0.2 (a tall cylinder) to 10.0 (a thin disk) has been studied. Series and parallel resonance frequencies for each of the modes are determined through an eigenfrequency analysis, and effective electromechanical coupling coefficients are calculated. The modal displacement fields in the disk are calculated to determine the physical nature of each mode. An analysis of the complete spectrum of piezoelectrically active modes as a function of diameter-thickness ratio is presented for the ceramic PZT-5H, including and identification of radial, edge, length expander, thickness shear, and thickness extensional vibrations. From this analysis, optimal diameter-to-thickness ratios for good transducer performance are discussed.

  7. Tracheal reconstruction with a pleuroperiosteal flap.

    PubMed

    Krespi, Y P; Biller, H F; Baek, S M

    1983-12-01

    Reconstruction of extensive tracheal defects remains a difficult surgical problem. In many experiments restoration of tracheal mucosa by autogenous or homologous soft tissue grafts has usually failed because of rejection or tracheal obstruction. This experimental work employed a two-stage surgical procedure that allowed reconstruction of extensive circumferential full-thickness defects of the trachea. Stage I involved the creation of a vascularized pleuroperiosteal flap that was formed into a rigid tube around a Silastic stent. Stage II consisted of creation of a full-thickness circumferential tracheal defect and repair with the flap in those animals in which a suitable rigid tube had been formed. The results of these experiments argue strongly that a vascularized composite pleuroperiosteal flap can produce an adequate tracheal replacement.

  8. Spontaneous closure of traumatic macular hole

    PubMed Central

    Sanjay, Srinivasan; Yeo, Tun Kuan; Au Eong, Kah-Guan

    2012-01-01

    Macular hole formation is a well-known complication following ocular trauma. Less commonly recognised is the spontaneous closure of such holes. A 27-year-old man presented with a history of blunt trauma to his left eye. Eye evaluation showed conjunctival laceration, diffuse retinal oedema and multiple retinal haemorrhages in that eye. A month later, he developed a full thickness macular hole. Two months later, there was spontaneous complete closure of the full-thickness macular hole in the left eye as confirmed on optical coherence tomography. Spontaneous closure of hole is not uncommon. Observation for a period of up to 12 months is a reasonable management option. Macular hole surgery for traumatic macular holes may be delayed in such cases. PMID:23961017

  9. The topical penta-peptide Gly-Pro-Ile-Gly-Ser increases the proportion of thick hair in Japanese men with androgenetic alopecia.

    PubMed

    Iwabuchi, Tokuro; Takeda, Shunsuke; Yamanishi, Haruyo; Ideta, Ritsuro; Ehama, Ritsuko; Tsuruda, Akinori; Shibata, Hideaki; Ito, Tomoko; Komatsu, Nobuyuki; Terai, Keiko; Oka, Syuichi

    2016-06-01

    A penta-peptide, Gly-Pro-Ile-Gly-Ser (GPIGS), promotes proliferation of mouse hair keratinocytes and accelerates hair growth in mice. This study focused on the ability of the peptide to promote human hair growth. We used a human hair keratinocyte proliferation assay and organ cultures of human hair follicle as in vitro systems. The lotions with and without the penta-peptide were administered to 22 Japanese men with androgenetic alopecia (AGA) for 4 months in a double-blind and randomized clinical study. The penta-peptide significantly stimulated the proliferation of human hair keratinocytes at a concentration of 2.3 μm (P < 0.01), and 5.0 μm of this peptide had a marked effect on hair shaft elongation in the organ culture (P < 0.05). The change in the proportion of thick hair (≥60 μm) compared to baseline in patients that received the peptide was significantly higher than in the placebo (P = 0.006). The change in the proportion of vellus hair (<40 μm) was also significantly lower in the peptide group than in the placebo (P = 0.029). The penta-peptide also significantly improved the appearance of baldness (P = 0.020) when blinded reviewers graded photographs of the participants according to a standardized baldness scale. No adverse dermatological effects due to treatment were noted during this clinical study. This penta-peptide promotes proliferation of human hair keratinocytes and hair shaft elongation of human hair follicles, in vitro. This peptide increases thick hair ratio in vivo, and this compound is useful for the improvement of AGA. © 2016 Wiley Periodicals, Inc.

  10. MRI findings associated with luxatio erecta humeri.

    PubMed

    Krug, David K; Vinson, Emily N; Helms, Clyde A

    2010-01-01

    Luxatio erecta humeri is a rare type of inferior glenohumeral dislocation with a unique radiographic appearance; however, the magnetic resonance imaging findings associated with this dislocation have not been described in the radiology literature. The purpose of this study is to identify magnetic resonance imaging findings associated with this uncommon type of glenohumeral dislocation. The magnetic resonance imaging features of four patients with clinical and radiographic evidence of luxatio erecta humeri were reviewed retrospectively by two musculoskeletal-trained radiologists. The reported mechanism of injury in all four patients was falling. The MR imaging examinations were evaluated for the presence of rotator cuff and biceps tendon pathology, glenoid labrum pathology, joint capsule and glenohumeral ligament injury, fractures and bone marrow contusions, articular cartilage injury, and joint effusions. All four patients demonstrated pathology of the glenohumeral joint. Three of the four patients demonstrated rotator cuff tears, including large full thickness tears of the supraspinatus and infraspinatus tendons in two patients, and small full thickness tear of the supraspinatus tendon with partial thickness tear of the infraspinatus tendon in the third patient. In the two patients with large full thickness tears of the supraspinatus and infraspinatus tendons, one patient demonstrated tearing of the subscapularis tendon with dislocation of a partially torn long head of the biceps tendon, and the second patient demonstrated full thickness tearing of the intra-articular biceps tendon. All four patients demonstrated injuries to the glenoid labrum and both anterior and posterior bands of the inferior glenohumeral ligament. Contusions or fractures of the humeral head were seen in two of the patients. Three of the four patients demonstrated cartilage abnormalities including a focal cartilage defect in the anterior inferior glenoid in one patient, and cartilage surface irregularity of the glenoid in the other two patients. Common magnetic resonance imaging findings in patients with a prior luxatio erecta humeri dislocation include rotator cuff tears, injury to the glenoid labrum, and injury to both the anterior and posterior bands of the inferior glenohumeral ligament. These findings are compatible with the mechanism of dislocation in luxatio erecta, and noting these findings on magnetic resonance imaging may suggest that the patient has sustained a prior inferiorly directed glenohumeral dislocation such as luxatio erecta.

  11. Goldmann tonometry tear film error and partial correction with a shaped applanation surface.

    PubMed

    McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M

    2018-01-01

    The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.

  12. LAMELLAR HOLE-ASSOCIATED EPIRETINAL PROLIFERATION IN LAMELLAR MACULAR HOLE AND FULL-THICKNESS MACULAR HOLE IN HIGH MYOPIA.

    PubMed

    Lai, Tso-Ting; Yang, Chung-May

    2017-05-18

    To report findings and surgical outcomes of lamellar macular hole (LMH) or full-thickness macular hole (FTMH) accompanied by lamellar hole-associated epiretinal proliferation (LHEP) in eyes with high myopia (HM). Consecutive cases of HM with LMH or FTMH containing LHEP were retrospectively reviewed (study group, 43 cases). Cases of HM without LHEP (22) and those of non-HM with LHEP (30) served as Control A and B. The study group showed larger (928.7 ± 381.9 μm) and deeper (remained base thickness: 79.7 ± 23.7 μm) LMH retinal defect than that in Control A (466.2 ± 179.1 and 99.9 ± 24.9) and B (647.1 ± 346.7 and 99.1 ± 38.1). Lamellar hole-associated epiretinal proliferation in the study group had a higher rate of wide extension (42.3%) and growing along the posterior hyaloid (PH, 53.8%). Patients with LMH who underwent surgery in the study group and Control A showed limited best corrected visual acuity (BCVA) improvement (0-1 and 1-2 ETDRS lines, respectively), while Control B had significant improvement (4-5 lines). For full-thickness macular holes, the study group was the youngest (50.0 ± 11.4) and LHEP was more likely to grow on the posterior hyaloid (23.5%); the postoperative best corrected visual acuity, however, was similar to that in Control A (20/63-20/80). Lamellar hole-associated epiretinal proliferation in HM tended to be more widespread and adherent to the posterior hyaloid than in eyes without HM. Visual outcomes after LMH repair in eyes with LHEP and HM are less favorable than eyes with LHEP and without HM, but similar to eyes with HM and without LHEP.

  13. Does partial tear repair of adjacent tendons improve the outcome of supraspinatus tendonfull-thickness tear reinsertion?

    PubMed

    Nich, C; Dhiaf, N; Di Schino, M; Augereau, B

    2014-11-01

    Partial tearing of the infraspinatus and/or subscapularis tendon(s) is frequently associated with supraspinatus full-thickness tears. However, limited data regarding its influence on supraspinatus surgical repair is available. Our aim was to assess the functional and anatomical outcomes of open repair of supraspinatus full-thickness tears combined with adjacent partial tearing, comparatively to a control. We retrospectively identified 22 patients (22 shoulders) with a partial tear, most of them being a delamination tear, of the infraspinatus and/or subscapularis tendons associated with a complete detachment of the supraspinatus tendon. Twenty-seven patients (27 shoulders) treated for an isolated complete detachment of the supraspinatus tendon by open repair served as controls. The mean age was 58 years. A proximalized trans-osseous reinsertion of the supraspinatus tendon was combined with a curettage-closure of the delamination tear. Patients were evaluated with standardized MRI at last follow-up. At a mean of 75-month follow-up, the presence of a partial tear of either infraspinatus or subscapularis, or both, did not influence function and healing rates of supraspinatus tendon repair. Conversely to the control, when a retear occurred, the functional score tended to worsen. Preoperatively, fatty muscular degeneration was more pronounced when a partial tear was present. Fatty degeneration worsened regardless of repair healing. Open reinsertion of a supraspinatus full-thickness tear associated with a thorough treatment of partial tear of adjacent tendons led to optimal functional and anatomical mid term outcomes. Our results suggest the presence of a partial tear of adjacent tendons could be associated with poorer function in case of supraspinatus tendon re-rupture. Level III case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.

    PubMed

    Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D

    2016-11-01

    Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Rapid and selective enzymatic debridement of porcine comb burns with bromelain-derived Debrase: acute-phase preservation of noninjured tissue and zone of stasis.

    PubMed

    Singer, Adam J; McClain, Steve A; Taira, Breena R; Rooney, Jean; Steinhauff, Nicole; Rosenberg, Lior

    2010-01-01

    Deep burns are associated with the formation of an eschar, which delays healing and increases the risk of infection. Surgical debridement of the eschar is, at present, the fastest means to achieve an eschar-free bed, but the process can not differentiate between the viable tissue and the eschar and follow the minute irregularities of the interface between the two. We evaluated the efficacy and selectivity of a novel enzymatic bromelain-based debriding agent, Debrase Gel Dressing (Debrase), in a porcine comb burn model. We hypothesized that Debrase would result in rapid debridement of the eschar without adverse effects on the surrounding uninjured skin. This is a prospective, controlled, animal experiment. Five domestic pigs (20-25 kg) were used in this study. Sixteen burns were created on each animal's dorsum using a brass comb with four rectangular prongs preheated in boiling water and applied for 30 seconds, resulting in four rectangular 10 x 20 mm full-thickness burns and separated by three 5 x 20 mm unburned interspaces representing the zone of stasis. The burned keratin layer (blisters) was removed, and the burns were treated with a single, topical, Debrase or control vehicle application for 4 hours. The Debrase/control was then wiped off using a metal forceps handle, and the burns were treated with a topical silver sulfadiazine (SSD). The wounds were observed, and full-thickness biopsies were obtained at 4 and 48 hours for evidence of dermal thickness, vascular thrombosis, and burn depth, both within the comb burns and the unburned interspaces in between them. Chi-square and t tests are used for data analysis. A single 4-hour topical application of Debrase resulted in rapid and complete eschar dissolution of all the burns in which the keratin layer was removed. The remaining dermis was thinner (1.1 +/- 0.7 mm) than in the control burns (2.1 +/- 0.3 mm; difference 0.9 mm [95% confidence interval: 0.3-1.4]) and was viable with no injury to the normal surrounding skin or to the unburned interspaces between the burns, which represents the zone of stasis. In control burns, the entire thickness of the dermis was necrotic. At 48 hours, Debrase-treated areas were found partially desiccated under SSD treatment. The unburned interspaces demonstrated partial-thickness necrosis in two third and full-thickness necrosis in one third of wounds. In contrast, full-thickness necrosis was noted in all control interspaces (P = .05). In a porcine comb burn model, a single, 4-hour topical application of Debrase resulted in rapid removal of the necrotic layer of the dermis with preservation of unburned tissues. At 48 hours, SSD treatment resulted in superficial tissue damage and partial preservation of the unburned interspaces.

  16. Fabrication of Fe3O4@mSiO2 Core-Shell Composite Nanoparticles for Drug Delivery Applications

    NASA Astrophysics Data System (ADS)

    Uribe Madrid, Sergio I.; Pal, Umapada; Kang, Young Soo; Kim, Junghoon; Kwon, Hyungjin; Kim, Jungho

    2015-05-01

    We report the synthesis of Fe3O4@mSiO2 nanostructures of different meso-silica (mSiO2) shell thickness, their biocompatibility and behaviors for loading and release of a model drug ibuprofen. The composite nanostructures have superparamagnetic magnetite cores of 208 nm average size and meso-silica shells of 15 to 40 nm thickness. A modified Stöber method was used to grow the meso-silica shells over the hydrothermally grown monodispersed magnetite particles. The composite nanoparticles show very promising drug holding and releasing behaviors, which depend on the thickness of meso-silica shell. The biocompatibility of the meso-silica-coated and uncoated magnetite nanoparticles was tested through cytotoxicity assay on breast cancer (MCF-7), ovarian cancer (SKOV3), normal human lung fibroblasts MRC-5, and IMR-90 cells. The high drug holding capacity and reasonable biocompatibility of the nanostructures make them ideal agents for targeted drug delivery applications in human body.

  17. Evaporation and Hydrocarbon Chain Conformation of Surface Lipid Films

    PubMed Central

    Sledge, Samiyyah M.; Khimji, Hussain; Borchman, Douglas; Oliver, Alexandria; Michael, Heidi; Dennis, Emily K.; Gerlach, Dylan; Bhola, Rahul; Stephen, Elsa

    2016-01-01

    Purpose The inhibition of the rate of evaporation (Revap) by surface lipids is relevant to reservoirs and dry eye. Our aim was to test the idea that lipid surface films inhibit Revap. Methods Revap were determined gravimetrically. Hydrocarbon chain conformation and structure were measured using a Raman microscope. Six 1-hydroxyl hydrocarbons (11–24 carbons in length) and human meibum were studied. Reflex tears were obtained from a 62-year-old male. Results The Raman scattering intensity of the lipid film deviated by about 7 % for hydroxyl lipids and varied by 21 % for meibum films across the entire film at a resolution of 5 µm2. All of the surface lipids were ordered. Revap of the shorter chain hydroxyl lipids were slightly (7%) but significantly lower compared with the longer chain hydroxyl lipids. Revap of both groups was essentially similar to that of buffer. A hydroxyl lipid film did not influence Revap over an estimated average thickness range of 0.69 to >6.9 µm. Revap of human tears and buffer with and without human meibum (34.4 µm thick) was not significantly different. Revap of human tears was not significantly different from buffer. Conclusions Human meibum and hydroxyl lipids, regardless of their fluidity, chain length, or thickness did not inhibit Revap of buffer or tears even though they completely covered the surface. It is unlikely that hydroxyl lipids can be used to inhibit Revap of reservoirs. Our data do not support the widely accepted (yet unconfirmed) idea that the tear film lipid layer inhibits Revap of tears. PMID:27395776

  18. Structural investigations of human hairs by spectrally resolved ellipsometry

    NASA Astrophysics Data System (ADS)

    Chan, Danny; Schulz, Benjamin; Rübhausen, Michael; Wessel, Sonya; Wepf, Roger

    2006-01-01

    Human hair is a biological layered system composed of two major layers, the cortex and the cuticle. We show spectrally resolved ellipsometry measurements of the ellipsometric parameters Ψ and Δ of single human hairs. The spectra reflect the layered nature of hair and the optical anisotropy of the hair's structure. In addition, measurements on strands of human hair show a high reproducibility of the ellipsometric parameters for different hair fiber bundles from the same person. Based on the measurements, we describe a dielectric model of hair that explains the spectra in terms of the dielectric properties of the major parts of hair and their associated layer thicknesses. In addition, surface roughness effects modeled by a roughness layer with a complex refractive index given by an effective medium approach can be seen to have a significant effect on the measurements. We derive values for the parameters of the cuticle surface roughness layer of the thickness dACu=273 to 360 nm and the air inclusion fA=0.6 to 5.7%.

  19. NDE application of ultrasonic tomography to a full-scale concrete structure.

    PubMed

    Choi, Hajin; Popovics, John S

    2015-06-01

    Newly developed ultrasonic imaging technology for large concrete elements, based on tomographic reconstruction, is presented. The developed 3-D internal images (velocity tomograms) are used to detect internal defects (polystyrene foam and pre-cracked concrete prisms) that represent structural damage within a large steel reinforced concrete element. A hybrid air-coupled/contact transducer system is deployed. Electrostatic air-coupled transducers are used to generate ultrasonic energy and contact accelerometers are attached on the opposing side of the concrete element to detect the ultrasonic pulses. The developed hybrid testing setup enables collection of a large amount of high-quality, through-thickness ultrasonic data without surface preparation to the concrete. The algebraic reconstruction technique is used to reconstruct p-wave velocity tomograms from the obtained time signal data. A comparison with a one-sided ultrasonic imaging method is presented for the same specimen. Through-thickness tomography shows some benefit over one-sided imaging for highly reinforced concrete elements. The results demonstrate that the proposed through-thickness ultrasonic technique shows great potential for evaluation of full-scale concrete structures in the field.

  20. Efficiency of a multilayer-Laue-lens with a 102 μm aperture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macrander, Albert T., E-mail: atm@anl.gov; Wojcik, Michael; Maser, Jorg

    2015-08-24

    A multilayer-Laue-lens (MLL) comprised of WSi{sub 2}/Al layers stacked to a full thickness of 102 μm was characterized for its diffraction efficiency and dynamical diffraction properties by x-ray measurements made in the far field. The achieved aperture roughly doubles the previous maximum reported aperture for an MLL, thereby doubling the working distance. Negative and positive first orders were found to have 14.2% and 13.0% efficiencies, respectively. A section thickness of 9.6 μm was determined from Laue-case thickness fringes in the diffraction data. A background gas consisting of 90% Ar and 10% N{sub 2} was used for sputtering. This material system wasmore » chosen to reduce grown-in stress as the multilayer is deposited. Although some regions of the full MLL exhibited defects, the presently reported results were obtained for a region devoid of defects. The data compare well to dynamical diffraction calculations with Coupled Wave Theory (CWT) which provided confirmation of the optical constants and densities assumed for the CWT calculations.« less

  1. Efficiency of a multilayer-Laue-lens with a 102 μm aperture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macrander, Albert T.; Kubec, Adam; Conley, Raymond

    2015-08-25

    A multilayer-Laue-lens (MLL) comprised of WSi 2/Al layers stacked to a full thickness of 102 microns was characterized for its diffraction efficiency and dynamical diffraction properties by x-ray measurements made in the far field. The achieved aperture roughly doubles the previous maximum reported aperture for an MLL, thereby doubling the working distance. Negative and positive first orders were found to have 14.2 % and 13.0 % efficiencies, respectively. A section thickness of 9.6 μm was determined from Laue-case thickness fringes in the diffraction data. A background gas consisting of 90 % Ar and 10 % N 2 was used formore » sputtering. This material system was chosen to reduce grown-in stress as the multilayer is deposited. Although some regions of the full MLL exhibited defects, the presently reported results were obtained for a region devoid of defects. The data compare well to dynamical diffraction calculations with Coupled Wave Theory (CWT) which provided confirmation of the optical constants and densities assumed for the CWT calculations.« less

  2. Interactive effects of dehydroepiandrosterone and testosterone on cortical thickness during early brain development.

    PubMed

    Nguyen, Tuong-Vi; McCracken, James T; Ducharme, Simon; Cropp, Brett F; Botteron, Kelly N; Evans, Alan C; Karama, Sherif

    2013-06-26

    Humans and the great apes are the only species demonstrated to exhibit adrenarche, a key endocrine event associated with prepubertal increases in the adrenal production of androgens, most significantly dehydroepiandrosterone (DHEA) and to a certain degree testosterone. Adrenarche also coincides with the emergence of the prosocial and neurobehavioral skills of middle childhood and may therefore represent a human-specific stage of development. Both DHEA and testosterone have been reported in animal and in vitro studies to enhance neuronal survival and programmed cell death depending on the timing, dose, and hormonal context involved, and to potentially compete for the same signaling pathways. Yet no extant brain-hormone studies have examined the interaction between DHEA- and testosterone-related cortical maturation in humans. Here, we used linear mixed models to examine changes in cortical thickness associated with salivary DHEA and testosterone levels in a longitudinal sample of developmentally healthy children and adolescents 4-22 years old. DHEA levels were associated with increases in cortical thickness of the left dorsolateral prefrontal cortex, right temporoparietal junction, right premotor and right entorhinal cortex between the ages of 4-13 years, a period marked by the androgenic changes of adrenarche. There was also an interaction between DHEA and testosterone on cortical thickness of the right cingulate cortex and occipital pole that was most significant in prepubertal subjects. DHEA and testosterone appear to interact and modulate the complex process of cortical maturation during middle childhood, consistent with evidence at the molecular level of fast/nongenomic and slow/genomic or conversion-based mechanisms underlying androgen-related brain development.

  3. Full-Field Indentation Damage Measurement Using Digital Image Correlation

    PubMed Central

    López-Alba, Elías; Díaz-Garrido, Francisco A.

    2017-01-01

    A novel approach based on full-field indentation measurements to characterize and quantify the effect of contact in thin plates is presented. The proposed method has been employed to evaluate the indentation damage generated in the presence of bending deformation, resulting from the contact between a thin plate and a rigid sphere. For this purpose, the 3D Digital Image Correlation (3D-DIC) technique has been adopted to quantify the out of plane displacements at the back face of the plate. Tests were conducted using aluminum thin plates and a rigid bearing sphere to evaluate the influence of the thickness and the material behavior during contact. Information provided by the 3D-DIC technique has been employed to perform an indirect measurement of the contact area during the loading and unloading path of the test. A symmetrical distribution in the contact damage region due to the symmetry of the indenter was always observed. In the case of aluminum plates, the presence of a high level of plasticity caused shearing deformation as the load increased. Results show the full-field contact damage area for different plates’ thicknesses at different loads. The contact damage region was bigger when the thickness of the specimen increased, and therefore, bending deformation was reduced. With the proposed approach, the elastic recovery at the contact location was quantified during the unloading, as well as the remaining permanent indentation damage after releasing the load. Results show the information obtained by full-field measurements at the contact location during the test, which implies a substantial improvement compared with pointwise techniques. PMID:28773137

  4. Influence of mesh density, cortical thickness and material properties on human rib fracture prediction.

    PubMed

    Li, Zuoping; Kindig, Matthew W; Subit, Damien; Kent, Richard W

    2010-11-01

    The purpose of this paper was to investigate the sensitivity of the structural responses and bone fractures of the ribs to mesh density, cortical thickness, and material properties so as to provide guidelines for the development of finite element (FE) thorax models used in impact biomechanics. Subject-specific FE models of the second, fourth, sixth and tenth ribs were developed to reproduce dynamic failure experiments. Sensitivity studies were then conducted to quantify the effects of variations in mesh density, cortical thickness, and material parameters on the model-predicted reaction force-displacement relationship, cortical strains, and bone fracture locations for all four ribs. Overall, it was demonstrated that rib FE models consisting of 2000-3000 trabecular hexahedral elements (weighted element length 2-3mm) and associated quadrilateral cortical shell elements with variable thickness more closely predicted the rib structural responses and bone fracture force-failure displacement relationships observed in the experiments (except the fracture locations), compared to models with constant cortical thickness. Further increases in mesh density increased computational cost but did not markedly improve model predictions. A ±30% change in the major material parameters of cortical bone lead to a -16.7 to 33.3% change in fracture displacement and -22.5 to +19.1% change in the fracture force. The results in this study suggest that human rib structural responses can be modeled in an accurate and computationally efficient way using (a) a coarse mesh of 2000-3000 solid elements, (b) cortical shells elements with variable thickness distribution and (c) a rate-dependent elastic-plastic material model. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Association Between Retinal Nerve Fiber Layer Thickness and Abnormalities of Vision in People With Human Immunodeficiency Virus Infection

    PubMed Central

    Kalyani, Partho S.; Holland, Gary N.; Fawzi, Amani A.; Arantes, Tiago E.F.; Yu, Fei; Sadun, Alfredo A.

    2014-01-01

    Purpose To investigate relationships between contrast sensitivity (CS), color vision, and retinal nerve fiber layer (RNFL) among people with human immunodeficiency virus (HIV) infection; to evaluate the effect of time since diagnosis of HIV infection on RNFL thickness. Design Noninterventional cross-sectional study. Methods We evaluated 102 eyes of 57 HIV-infected individuals without ocular opportunistic infections. Peripapillary RNFL thickness was determined with spectraldomain optical coherence tomography in 4 quadrants. CS was measured with the Pelli-Robson technique (expressed as logCS); color vision was measured with the Lanthony desaturated 15-hue technique (expressed as color confusion index [C-index], with higher scores indicating worse color vision). Correlations between values were assessed using Spearman correlation coefficients. Results Median RNFL thickness (average of 4 quadrants) was 102.9 μm (range, 75.0–134.7 μm). Median logCS was 1.90 (range, 1.25–1.95). Median C-index was 1.58 (range, 0.96–4.07). Temporal RNFL thickness was correlated with logCS (r = 0.295, P = .003) and C-index (r = −0.338, P = .0005). Time since diagnosis of HIV infection was shorter for those with thick average RNFL than for those with thin average RNFL (P = .18). Conclusions Both worse CS and worse color vision are correlated with thinning of the temporal RNFL, with possible threshold effects. Increased prevalences of abnormal CS and abnormal color vision in this population are therefore likely attributable to neuroretinal compromise. This pattern of structural and functional losses may reflect preferential damage to small-caliber axons in the maculopapillary bundle, possibly associated with mitochondrial dysfunction, providing a potential disease mechanism for HIV-associated “neuroretinal disorder.” PMID:22245459

  6. Dose in critical body organs in low Earth orbit

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; Cucinotta, F.

    1984-01-01

    Human exposure to trapped radiations in low Earth orbit (LEO) are evaluated on the basis of a simple approximation of the human geometry for spherical shell shields of varying thickness. A data base is presented that may be used to make preliminary assessment of the impact of radiation exposure constraints on human performance. A sample impact assessment is discussed.

  7. Predicting human age using regional morphometry and inter-regional morphological similarity

    NASA Astrophysics Data System (ADS)

    Wang, Xun-Heng; Li, Lihua

    2016-03-01

    The goal of this study is predicting human age using neuro-metrics derived from structural MRI, as well as investigating the relationships between age and predictive neuro-metrics. To this end, a cohort of healthy subjects were recruited from 1000 Functional Connectomes Project. The ages of the participations were ranging from 7 to 83 (36.17+/-20.46). The structural MRI for each subject was preprocessed using FreeSurfer, resulting in regional cortical thickness, mean curvature, regional volume and regional surface area for 148 anatomical parcellations. The individual age was predicted from the combination of regional and inter-regional neuro-metrics. The prediction accuracy is r = 0.835, p < 0.00001, evaluated by Pearson correlation coefficient between predicted ages and actual ages. Moreover, the LASSO linear regression also found certain predictive features, most of which were inter-regional features. The turning-point of the developmental trajectories in human brain was around 40 years old based on regional cortical thickness. In conclusion, structural MRI could be potential biomarkers for the aging in human brain. The human age could be successfully predicted from the combination of regional morphometry and inter-regional morphological similarity. The inter-regional measures could be beneficial to investigating human brain connectome.

  8. Comparison of corneal thickness after the instillation of topical anesthetics: proparacaine versus oxybuprocaine.

    PubMed

    Nam, Sang Min; Lee, Hyung Keun; Kim, Eung Kweon; Seo, Kyoung Yul

    2006-01-01

    To compare changes in human corneal thickness after the instillation of proparacaine with those after oxybuprocaine instillation with time over a period of 10 minutes. Eighteen healthy young participants were recruited. Proparacaine was used in the right eye and oxybuprocaine in the left. Right and left baseline corneal thicknesses were measured every 30 seconds for 10 minutes using a noncontact specular microscope by 1 observer. Baseline corneal thickness was defined as the average of all values taken over 10 minutes. Changes in corneal thickness were measured every 20 seconds for 10 minutes after the administration of 1 drop of 0.5% proparacaine onto the right cornea and 1 drop of 0.4% oxybuprocaine onto the left cornea. Mean baseline right cornea thickness was 531 +/- 45 microm, and that of the left cornea was 531 +/- 42 microm. The corneal thickness after proparacaine increased by 8.6 microm ( approximately 4.5-12.6 microm, 95% CI) and then returned to baseline within 80 seconds. Corneal thickness after applying oxybuprocaine increased by 7.7 microm (3.6-11.2 microm, 95% CI) and then returned to baseline within 80 seconds. There was a second transient increase about 5 minutes later after proparacaine instillation but no additional transient increase after oxybuprocaine instillation. Oxybuprocaine is similar to proparacaine in terms of the severity of its effect on corneal thickness. Corneal thickness instability may occur for 5 minutes after proparacaine administration. Changes in corneal thickness after topical anesthetic instillation should be considered when performing measurements for refractive surgery or central corneal thickness in glaucoma patients.

  9. Electrothermal ring burn from a car battery.

    PubMed

    Sibley, Paul A; Godwin, Kenneth A

    2013-08-01

    Despite prevention efforts, burn injuries among auto mechanics are described in the literature. Electrothermal ring burns from car batteries occur by short-circuiting through the ring when it touches the open terminal or metal housing. This article describes a 34-year-old male auto mechanic who was holding a wrench when his gold ring touched the positive terminal of a 12-volt car battery and the wrench touched both his ring and the negative terminal. He felt instant pain and had a deep partial-thickness circumferential burn at the base of his ring finger. No other soft tissues were injured. He was initially managed conservatively, but after minimal healing at 3 weeks, he underwent a full-thickness skin graft. The graft incorporated well and healed by 4 weeks postoperatively. He had full range of motion. The cause of ring burns has been controversial, but based on reports similar to the current patient's mechanism, they are most likely electrothermal burns. Gold, a metal with high thermal conductivity, can heat up to its melting point in a matter of seconds. Many treatments have been described, including local wound care to split- and full-thickness skin grafts. Because most burns are preventable, staff should be warned and trained about the potential risks of contact burns. All jewelry should be removed, and the live battery terminal should be covered while working in the vicinity of the battery. Copyright 2013, SLACK Incorporated.

  10. LED phototherapy in full-thickness burns induced by CO2 laser in rats skin.

    PubMed

    da Silva Melo, Milene; Alves, Leandro Procópio; Fernandes, Adriana Barrinha; Carvalho, Henrique Cunha; de Lima, Carlos José; Munin, Egberto; Gomes, Mônica Fernandes; Salgado, Miguel Angel Castillo; Zângaro, Renato Amaro

    2018-04-27

    Many studies have been conducted on the treatment of burns because they are important in morbidity and mortality. These studies are mainly focused on improving care and quality of life of patients. The aim of this study was evaluate the LED phototherapy effects in rats skin full-thickness burns induced by CO 2 laser. The animals were divided in NT group that did not received any treatment and LED group that received LED irradiation at 685 nm, 220 mW, and 4.5 J/cm 2 during 40 s by burned area. Biopsies were obtained after 7, 14, and 21 days of treatment and submitted to histological and immunohistochemical analysis. The LED phototherapy shows anti-inflammatory effects, improves angiogenesis, and stimulates the migration and proliferation of fibroblasts. The T CD8+ lymphocytes were more common in burned areas compared to T CD4+ lymphocytes since statistically significant differences were observed in the LED group compared to the NT group after 7 days of treatment. These results showed that LED phototherapy performs positive influence in full-thickness burns repair from the healing process modulated by cellular immune response. The obtained results allowed inferring that burns exhibit a characteristic cell immune response and this cannot be extrapolated to other wounds such as incision and wounds induced by punch, among others.

  11. Additive-free thick graphene film as an anode material for flexible lithium-ion batteries.

    PubMed

    Rana, Kuldeep; Kim, Seong Dae; Ahn, Jong-Hyun

    2015-04-28

    This work demonstrates a simple route to develop mechanically flexible electrodes for Li-ion batteries (LIBs) that are usable as lightweight effective conducting networks for both cathodes and anodes. Removing electrochemically dead elements, such as binders, conducting agents and metallic current collectors, from the battery components will allow remarkable progress in this area. To investigate the feasibility of using thick, additive-free graphene films as anodes for flexible LIBs, we have synthesized and tested thick, additive-free, freestanding graphene films as anodes, first in a coin cell and further in a flexible full cell. As an anode material in a half cell, it showed a discharge capacity of about 350 mA h g(-1) and maintained nearly this capacity over 50 cycles at various current rates. This film was also tested as an anode material in a full cell with a LiCoO2 cathode and showed good electrochemical performance. Because the graphene-based flexible film showed good performance in half- and full coin cells, we used this film as a flexible anode for flexible LIBs. No conducting agent or binder was used in the anode side, which helped in realizing the flexible LIBs. Using this, we demonstrate a thin, lightweight and flexible lithium ion battery with good electrochemical performance in both its flat and bent states.

  12. Chitosan: A potential biopolymer for wound management.

    PubMed

    Bano, Ijaz; Arshad, Muhammad; Yasin, Tariq; Ghauri, Muhammad Afzal; Younus, Muhammad

    2017-09-01

    It has been seen that slow healing and non-healing wounds conditions are treatable but still challenging to humans. Wound dressing usually seeks for biocompatible and biodegradable recipe. Natural polysaccharides like chitosan have been examined for its antimicrobial and healing properties on the basis of its variation in molecular weight and degree of deacetylation. Chitosan adopts some vital characteristics for treatment of various kinds of wounds which include its bonding nature, antifungal, bactericidal and permeability to oxygen. Chitosan therefore has been modified into various forms for the treatment of wounds and burns. The purpose of this review article is to understand the exploitation of chitosan and its derivatives as wound dressings. This article will also provide a concise insight on the properties of chitosan necessary for skin healing and regeneration, particularly highlighting the emerging role of chitosan films as next generation skin substitutes for the treatment of full thickness wounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Irradiated homologous tarsal plate banking: A new alternative in eyelid reconstruction. Part I. Technique and animal research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jordan, D.R.; Tse, D.T.; Anderson, R.L.

    1990-01-01

    Reconstruction of full thickness eyelid defects requires the correction of both posterior lamella (tarsus, conjunctiva) and anterior lamella (skin, muscle). Tarsal substitutes including banked sclera, nasal cartilage, ear cartilage, and periosteum can be beneficial for posterior lamellar repair, while anterior lamellar replacement, including skin grafts, pedicle flaps, advancement flaps, etc., is important to cover the posterior reconstructed portion. At times, due to extensive tissue loss, the eyelid reconstruction can be particularly challenging. We have found an alternative posterior lamellar reconstructive technique utilizing irradiated homologous tarsal plate that can be particularly useful in selected cases of severe tissue loss. The experimentalmore » surgical procedure in monkeys and the histological fate of the implanted tarsus is described in Part I, and followed in Part II by our experience with this tissue in six human patients.« less

  14. A clinical evaluation of resorbable hydroxylapatite for the repair of human intra-osseous defects.

    PubMed

    Corsair, A

    1990-01-01

    One of the goals of periodontal therapy is actual hard- and soft-tissue regeneration or at least the functional repair of periodontal defects. Alloplastic materials used in the past included dense hydroxylapatite grafts which were non-resorbable and often exfoliated. A new resorbable hydroxylapatite biomaterial [OsteoGen (HA RESORB)] was used during flap surgery. After the usual initial therapy, full-thickness flaps were elevated. A through debridement of the roots and osseous defects was accomplished. The defects were measured and then filled with OsteoGen. The mean initial bone defect depth was 4.47 mm. These defects were re-evaluated by the probing of bone levels after a 4-6-month healing period. A mean of 2.26 mm of new bone fill was obtained. This represents an average fill of 51%. Seventeen of the 22 defects had 42% or more actual new bone fill. No foreign body reaction or exfoliation occurred.

  15. Technical Note: Guidelines for the digital computation of 2D and 3D enamel thickness in hominoid teeth.

    PubMed

    Benazzi, Stefano; Panetta, Daniele; Fornai, Cinzia; Toussaint, Michel; Gruppioni, Giorgio; Hublin, Jean-Jacques

    2014-02-01

    The study of enamel thickness has received considerable attention in regard to the taxonomic, phylogenetic and dietary assessment of human and non-human primates. Recent developments based on two-dimensional (2D) and three-dimensional (3D) digital techniques have facilitated accurate analyses, preserving the original object from invasive procedures. Various digital protocols have been proposed. These include several procedures based on manual handling of the virtual models and technical shortcomings, which prevent other scholars from confidently reproducing the entire digital protocol. There is a compelling need for standard, reproducible, and well-tailored protocols for the digital analysis of 2D and 3D dental enamel thickness. In this contribution we provide essential guidelines for the digital computation of 2D and 3D enamel thickness in hominoid molars, premolars, canines and incisors. We modify previous techniques suggested for 2D analysis and we develop a new approach for 3D analysis that can also be applied to premolars and anterior teeth. For each tooth class, the cervical line should be considered as the fundamental morphological feature both to isolate the crown from the root (for 3D analysis) and to define the direction of the cross-sections (for 2D analysis). Copyright © 2013 Wiley Periodicals, Inc.

  16. The effect of body postures on the distribution of air gap thickness and contact area.

    PubMed

    Mert, Emel; Psikuta, Agnes; Bueno, Marie-Ange; Rossi, René M

    2017-02-01

    The heat and mass transfer in clothing is predominantly dependent on the thickness of air layer and the magnitude of contact area between the body and the garment. The air gap thickness and magnitude of the contact area can be affected by the posture of the human body. Therefore, in this study, the distribution of the air gap and the contact area were investigated for different body postures of a flexible manikin. In addition, the effect of the garment fit (regular and loose) and style (t-shirts, sweatpants, jacket and trousers) were analysed for the interaction between the body postures and the garment properties. A flexible manikin was scanned using a three-dimensional (3D) body scanning technique, and the scans were post-processed in dedicated software. The body posture had a strong effect on the air gap thickness and the contact area for regions where the garment had a certain distance from the body. Furthermore, a mathematical model was proposed to estimate the possible heat transfer coefficient for the observed air layers and their change with posture. The outcome of this study can be used to improve the design of the protective and functional garments and predict their effect on the human body.

  17. Human cranial vault thickness in a contemporary sample of 1097 autopsy cases: relation to body weight, stature, age, sex and ancestry.

    PubMed

    De Boer, H H Hans; Van der Merwe, A E Lida; Soerdjbalie-Maikoe, V Vidija

    2016-09-01

    The relation between human cranial vault thickness (CVT) and various elements of the physical anthropological biological profile is subject of ongoing discussion. Some results seem to indicate no correlation between CVT and the biological profile of the individual, whereas other results suggest that CVT measurements might be useful for identification purposes. This study assesses the correlation between CVT and body weight, stature, age, sex, and ancestry by reviewing data of 1097 forensic autopsies performed at the Netherlands Forensic Institute (NFI). In subadults (younger than 19 years of age at the time of death), all frontal, temporal, and occipital CVT measurements correlated moderately to strongly with indicators of growth (body weight, stature, and age). Neither sex nor ancestry correlated significantly with cranial thickness. In adults, body weight correlated with all CVT measurements. No meaningful correlation was found between CVT and stature or age. Females showed to have thicker frontal bones, and the occipital region was thicker in the Negroid subsample. All correlation in the adult group was weak, with the distribution of cranial thickness overlapping for a great deal between the groups. Based on these results, it was concluded that CVT generally cannot be used as an indicator for any part of the biological profile.

  18. Ultrathin Ceramic Membranes as Scaffolds for Functional Cell Coculture Models on a Biomimetic Scale

    PubMed Central

    Jud, Corinne; Ahmed, Sher; Müller, Loretta; Kinnear, Calum; Vanhecke, Dimitri; Umehara, Yuki; Frey, Sabine; Liley, Martha; Angeloni, Silvia; Petri-Fink, Alke; Rothen-Rutishauser, Barbara

    2015-01-01

    Abstract Epithelial tissue serves as an interface between biological compartments. Many in vitro epithelial cell models have been developed as an alternative to animal experiments to answer a range of research questions. These in vitro models are grown on permeable two-chamber systems; however, commercially available, polymer-based cell culture inserts are around 10 μm thick. Since the basement membrane found in biological systems is usually less than 1 μm thick, the 10-fold thickness of cell culture inserts is a major limitation in the establishment of realistic models. In this work, an alternative insert, accommodating an ultrathin ceramic membrane with a thickness of only 500 nm (i.e., the Silicon nitride Microporous Permeable Insert [SIMPLI]-well), was produced and used to refine an established human alveolar barrier coculture model by both replacing the conventional inserts with the SIMPLI-well and completing it with endothelial cells. The structural–functional relationship of the model was evaluated, including the translocation of gold nanoparticles across the barrier, revealing a higher translocation if compared to corresponding polyethylene terephthalate (PET) membranes. This study demonstrates the power of the SIMPLI-well system as a scaffold for epithelial tissue cell models on a truly biomimetic scale, allowing construction of more functionally accurate models of human biological barriers. PMID:26713225

  19. Early cessation of pressure garment therapy results in scar contraction and thickening

    PubMed Central

    DeBruler, Danielle M.; Zbinden, Jacob C.; Baumann, Molly E.; Blackstone, Britani N.; Malara, Megan M.; Bailey, J. Kevin

    2018-01-01

    Pressure garment therapy is often prescribed to improve scar properties following full-thickness burn injuries. Pressure garment therapy is generally recommended for long periods of time following injury (1–2 years), though it is plagued by extremely low patient compliance. The goal of this study was to examine the effects of early cessation of pressure garment therapy on scar properties. Full-thickness burn injuries were created along the dorsum of red Duroc pigs. The burn eschar was excised and wound sites autografted with split-thickness skin. Scars were treated with pressure garments within 1 week of injury and pressure was maintained for either 29 weeks (continuous pressure) or for 17 weeks followed by cessation of pressure for an additional 12 weeks (pressure released); scars receiving no treatment served as controls. Scars that underwent pressure garment therapy were significantly smoother and less contracted with decreased scar height compared to control scars at 17 weeks. These benefits were maintained in the continuous pressure group until week 29. In the pressure released group, grafts significantly contracted and became more raised, harder and rougher after the therapy was discontinued. Pressure cessation also resulted in large changes in collagen fiber orientation and increases in collagen fiber thickness. The results suggest that pressure garment therapy effectively improves scar properties following severe burn injury; however, early cessation of the therapy results in substantial loss of these improvements. PMID:29897933

  20. Early cessation of pressure garment therapy results in scar contraction and thickening.

    PubMed

    DeBruler, Danielle M; Zbinden, Jacob C; Baumann, Molly E; Blackstone, Britani N; Malara, Megan M; Bailey, J Kevin; Supp, Dorothy M; Powell, Heather M

    2018-01-01

    Pressure garment therapy is often prescribed to improve scar properties following full-thickness burn injuries. Pressure garment therapy is generally recommended for long periods of time following injury (1-2 years), though it is plagued by extremely low patient compliance. The goal of this study was to examine the effects of early cessation of pressure garment therapy on scar properties. Full-thickness burn injuries were created along the dorsum of red Duroc pigs. The burn eschar was excised and wound sites autografted with split-thickness skin. Scars were treated with pressure garments within 1 week of injury and pressure was maintained for either 29 weeks (continuous pressure) or for 17 weeks followed by cessation of pressure for an additional 12 weeks (pressure released); scars receiving no treatment served as controls. Scars that underwent pressure garment therapy were significantly smoother and less contracted with decreased scar height compared to control scars at 17 weeks. These benefits were maintained in the continuous pressure group until week 29. In the pressure released group, grafts significantly contracted and became more raised, harder and rougher after the therapy was discontinued. Pressure cessation also resulted in large changes in collagen fiber orientation and increases in collagen fiber thickness. The results suggest that pressure garment therapy effectively improves scar properties following severe burn injury; however, early cessation of the therapy results in substantial loss of these improvements.

  1. Cleaning with a wet sterile gauze significantly reduces contamination of sutures, instruments, and surgical gloves in an ex-vivo pelvic flexure enterotomy model in horses

    PubMed Central

    Giusto, Gessica; Tramuta, Clara; Caramello, Vittorio; Comino, Francesco; Nebbia, Patrizia; Robino, Patrizia; Singer, Ellen; Grego, Elena; Gandini, Marco

    2017-01-01

    The objective of this study was to investigate whether cleaning surgical materials used to close pelvic flexure enterotomies with a wet sterile gauze will reduce contamination and whether the use of a full thickness appositional suture pattern (F) or a partial thickness inverting (or Cushing) suture pattern (C) would make a difference in the level of contamination. Large colon specimens were assigned to group F or C and divided into subgroups N and G. In group G, a wet sterile gauze was passed over the suture material, another over the instruments, and another over the gloves. In group N, no treatment was applied. The bacterial concentration was measured by optical density (OD) at 24 h. The OD of subgroup CG was lower than that of subgroup CN (P = 0.019). The OD of subgroup FG was lower than that of subgroup FN (P = 0.02). The OD of subgroups CG, CN, FG, and FN was lower than that of the negative control (P < 0.003, P < 0.001, P < 0.001, and P < 0.00). The use of a sterile wet gauze significantly reduced contamination of suture materials. A partial thickness inverting suture pattern did not produce less contamination than a full thickness appositional suture pattern. PMID:28154467

  2. [Effects of human engineering activities on permafrost active layer and its environment in northern Qinghai-Tibetan plateau].

    PubMed

    Guo, Zhenggang; Wu, Qingbo; Niu, Fujun

    2006-11-01

    With disturbed and undisturbed belts during the construction of Qinghai-Tibet highway as test objectives, this paper studied the effects of human engineering activities on the permafrost ecosystem in northern Qinghai-Tibetan plateau. The results showed that the thickness of permafrost active layer was smaller in disturbed than in undisturbed belt, and decreased with increasing altitude in undisturbed belt while no definite pattern was observed in disturbed belt. Different vegetation types had different effects on the thickness of permafrost active layer, being decreased in the order of steppe > shrub > meadow. In the two belts, altitude was the main factor affecting the vertical distribution of soil moisture, but vegetation type was also an important affecting factor if the altitude was similar. Due to the human engineering activities, soil temperature in summer was lower in disturbed than in undisturbed belt.

  3. Organizing Principles of Human Cortical Development--Thickness and Area from 4 to 30 Years: Insights from Comparative Primate Neuroanatomy.

    PubMed

    Amlien, Inge K; Fjell, Anders M; Tamnes, Christian K; Grydeland, Håkon; Krogsrud, Stine K; Chaplin, Tristan A; Rosa, Marcello G P; Walhovd, Kristine B

    2016-01-01

    The human cerebral cortex undergoes a protracted, regionally heterogeneous development well into young adulthood. Cortical areas that expand the most during human development correspond to those that differ most markedly when the brains of macaque monkeys and humans are compared. However, it remains unclear to what extent this relationship derives from allometric scaling laws that apply to primate brains in general, or represents unique evolutionary adaptations. Furthermore, it is unknown whether the relationship only applies to surface area (SA), or also holds for cortical thickness (CT). In 331 participants aged 4 to 30, we calculated age functions of SA and CT, and examined the correspondence of human cortical development with macaque to human expansion, and with expansion across nonhuman primates. CT followed a linear negative age function from 4 to 30 years, while SA showed positive age functions until 12 years with little further development. Differential cortical expansion across primates was related to regional maturation of SA and CT, with age trajectories differing between high- and low-expanding cortical regions. This relationship adhered to allometric scaling laws rather than representing uniquely macaque-human differences: regional correspondence with human development was as large for expansion across nonhuman primates as between humans and macaque. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  4. Cortical Structure of Hallucal Metatarsals and Locomotor Adaptations in Hominoids

    PubMed Central

    Jashashvili, Tea; Dowdeswell, Mark R.; Lebrun, Renaud; Carlson, Kristian J.

    2015-01-01

    Diaphyseal morphology of long bones, in part, reflects in vivo loads experienced during the lifetime of an individual. The first metatarsal, as a cornerstone structure of the foot, presumably expresses diaphyseal morphology that reflects loading history of the foot during stance phase of gait. Human feet differ substantially from those of other apes in terms of loading histories when comparing the path of the center of pressure during stance phase, which reflects different weight transfer mechanisms. Here we use a novel approach for quantifying continuous thickness and cross-sectional geometric properties of long bones in order to test explicit hypotheses about loading histories and diaphyseal structure of adult chimpanzee, gorilla, and human first metatarsals. For each hallucal metatarsal, 17 cross sections were extracted at regularly-spaced intervals (2.5% length) between 25% and 65% length. Cortical thickness in cross sections was measured in one degree radially-arranged increments, while second moments of area were measured about neutral axes also in one degree radially-arranged increments. Standardized thicknesses and second moments of area were visualized using false color maps, while penalized discriminant analyses were used to evaluate quantitative species differences. Humans systematically exhibit the thinnest diaphyseal cortices, yet the greatest diaphyseal rigidities, particularly in dorsoplantar regions. Shifts in orientation of maximum second moments of area along the diaphysis also distinguish human hallucal metatarsals from those of chimpanzees and gorillas. Diaphyseal structure reflects different loading regimes, often in predictable ways, with human versus non-human differences probably resulting both from the use of arboreal substrates by non-human apes and by differing spatial relationships between hallux position and orientation of the substrate reaction resultant during stance. The novel morphological approach employed in this study offers the potential for transformative insights into form-function relationships in additional long bones, including those of extinct organisms (e.g., fossils). PMID:25635768

  5. In vitro comparison of the radiopacity of cavity lining materials with human dental structures

    PubMed Central

    Pires de Souza, Fernanda CP; Pardini, Luiz C; Cruvinel, Diogo R; Hamida, Hisham M; Garcia, Lucas FR

    2010-01-01

    Aim: To compare the optical densities (OD) of calcium hydroxide (CH) and glass ionomer cement with the same thicknesses of the dental structures. Materials and Methods: Eighteen specimens of each material, with thicknesses of 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm were made in a Teflon matrix. To compare the radiopacity of the materials with the dental structures, dental cuts of the first molars, increasing in thickness from 0.5 to 3.0 mm, were obtained. To standardize the radiographs, a transparent acrylic matrix (Standardizing Device) was developed and used. Thirty radiographs were taken, five for each tested material. Results: Statistical analysis (Two-way ANOVA - Bonferroni, P < 0.05) demonstrated that when the materials were compared, there was statistically significant difference between the ODs, only for the thickness of 1.0 mm (P < 0.05). Conclusion: The thickness of the material contributed to its radiopacity, and these materials had to be used in a thickness between 1.5 and 2.0 mm. PMID:20859477

  6. Thickness determination of large-area films of yttria-stabilized zirconia produced by pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Pryds, N.; Toftmann, B.; Bilde-Sørensen, J. B.; Schou, J.; Linderoth, S.

    2006-04-01

    Films of yttria-stabilized zirconia (YSZ) on a polished silicon substrate of diameter up to 125 mm have been produced in a large-area pulsed laser deposition (PLD) setup under typical PLD conditions. The film thickness over the full film area has been determined by energy-dispersive X-ray spectrometry in a scanning electron microscope (SEM) with use of a method similar to one described by Bishop and Poole. The attenuation of the electron-induced X-rays from the Si wafer by the film was monitored at a number of points along a diameter and the thickness was determined by Monte Carlo simulations of the attenuation for various values of film thickness with the program CASINO. These results have been compared with direct measurements in the SEM of the film thickness on a cross-section on one of the wafers. The results of these measurements demonstrate the ability of this technique to accurately determine the thickness of a large film, i.e. up to diameters of 125 mm, in a relatively short time, without destroying the substrate, without the need of a standard sample and without the need of a flat substrate. We have also demonstrated that by controlling the deposition parameters large-area YSZ films with uniform thickness can be produced.

  7. Structure-mechanical function relations at nano-scale in heat-affected human dental tissue.

    PubMed

    Sui, Tan; Sandholzer, Michael A; Le Bourhis, Eric; Baimpas, Nikolaos; Landini, Gabriel; Korsunsky, Alexander M

    2014-04-01

    The knowledge of the mechanical properties of dental materials related to their hierarchical structure is essential for understanding and predicting the effect of microstructural alterations on the performance of dental tissues in the context of forensic and archaeological investigation as well as laser irradiation treatment of caries. So far, few studies have focused on the nano-scale structure-mechanical function relations of human teeth altered by chemical or thermal treatment. The response of dental tissues to thermal treatment is thought to be strongly affected by the mineral crystallite size, their spatial arrangement and preferred orientation. In this study, synchrotron-based small and wide angle X-ray scattering (SAXS/WAXS) techniques were used to investigate the micro-structural alterations (mean crystalline thickness, crystal perfection and degree of alignment) of heat-affected dentine and enamel in human dental teeth. Additionally, nanoindentation mapping was applied to detect the spatial and temperature-dependent nano-mechanical properties variation. The SAXS/WAXS results revealed that the mean crystalline thickness distribution in dentine was more uniform compared with that in enamel. Although in general the mean crystalline thickness increased both in dentine and enamel as the temperature increased, the local structural variations gradually reduced. Meanwhile, the hardness and reduced modulus in enamel decreased as the temperature increased, while for dentine, the tendency reversed at high temperature. The analysis of the correlation between the ultrastructure and mechanical properties coupled with the effect of temperature demonstrates the effect of mean thickness and orientation on the local variation of mechanical property. This structural-mechanical property alteration is likely to be due to changes of HAp crystallites, thus dentine and enamel exhibit different responses at different temperatures. Our results enable an improved understanding of the mechanical properties correlation in hierarchical biological materials, and human dental tissue in particular. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Facial Soft Tissue Thickness of Midline in an Iranian Sample: MRI Study.

    PubMed

    Johari, Masume; Esmaeili, Farzad; Hamidi, Hadi

    2017-01-01

    To identify human skeletal remains, different methods can be used and using these techniques, important data can be obtained. However, facial reconstruction is the last method to indentify unknown human faces which requires knowledge about facial soft tissue thickness in the different positions of the face. The present study determined the facial soft tissue thickness in the different landmark points on the MRI images of patients referred to Radiology Department of Shahid Madani Hospital. In this descriptive cross-sectional trial, MRI images of 179 patients (61 males, 118 females) in the age range of 18-76 years old who did not show any pathologic lesions, were selected. The measurements of the facial soft tissue were done on 12 landmark points on the midline area by two radiologist observers using specific software on the images. The differences in the soft tissue thickness in these landmark points were statistically analyzed by Mann-Whitney U (in term of gender) and Kruskal-Wallis tests (in terms of Body Mass Index [BMI] and age groups). P value less than 0.05 was considered statistically significant. The data were compared with the results of other studies. The results obtained in the present study were higher than Turkish and American studies in most of the landmark points. Facial soft tissue thickness in most of the landmarks was more in males than females. In some of the landmarks, significant differences were found between emaciated, normal and overweight patients while in most cases, soft tissue thickness increased with the increased BMI. In some cases, significant differences were noted between soft tissue thickness values among the different age groups, in which the thickness increased or thinned with the increased age. There were statistically significant associations between the presence and surface area of Haller cells and the occurrence of ipsilateral maxillary sinusitis. Neither the angulation of the uncinate process nor the size of the maxillary sinus ostium significantly correlates with the formation of maxillary sinusitis. The data achieved in the present study can be used for the facial reconstruction purposes in the Iranian population; however, the slight differences existing between the studied population and other subgroup races must be considered for accurate reconstructions.

  9. Endothelial network formed with human dermal microvascular endothelial cells in autologous multicellular skin substitutes.

    PubMed

    Ponec, Maria; El Ghalbzouri, Abdoelwaheb; Dijkman, Remco; Kempenaar, Johanna; van der Pluijm, Gabri; Koolwijk, Pieter

    2004-01-01

    A human skin equivalent from a single skin biopsy harboring keratinocytes and melanocytes in the epidermal compartment, and fibroblasts and microvascular dermal endothelial cells in the dermal compartment was developed. The results of the study revealed that the nature of the extracellular matrix of the dermal compartments plays an important role in establishment of endothelial network in vitro. With rat-tail type I collagen matrices only lateral but not vertical expansion of endothelial networks was observed. In contrast, the presence of extracellular matrix of entirely human origin facilitated proper spatial organization of the endothelial network. Namely, when human dermal fibroblasts and microvascular endothelial cells were seeded on the bottom of an inert filter and subsequently epidermal cells were seeded on top of it, fibroblasts produced extracellular matrix throughout which numerous branched tubes were spreading three-dimensionally. Fibroblasts also facilitated the formation of basement membrane at the epidermal/matrix interface. Under all culture conditions, fully differentiated epidermis was formed with numerous melanocytes present in the basal epidermal cell layer. The results of the competitive RT-PCR revealed that both keratinocytes and fibroblasts expressed VEGF-A, -B, -C, aFGF and bFGF mRNA, whereas fibroblasts also expressed VEGF-D mRNA. At protein level, keratinocytes produced 10 times higher amounts of VEGF-A than fibroblasts did. The generation of multicellular skin equivalent from a single human skin biopsy will stimulate further developments for its application in the treatment of full-thickness skin defects. The potential development of biodegradable, biocompatible material suitable for these purposes is a great challenge for future research.

  10. Three-dimensional positioning and structure of chromosomes in a human prophase nucleus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Bo; Yusuf, Mohammed; Hashimoto, Teruo

    The human genetic material is packaged into 46 chromosomes. The structure of chromosomes is known at the lowest level, where the DNA chain is wrapped around a core of eight histone proteins to form nucleosomes. Around a million of these nucleosomes, each about 11 nm in diameter and 6 nm in thickness, are wrapped up into the complex organelle of the chromosome, whose structure is mostly known at the level of visible light microscopy to form a characteristic cross shape in metaphase. However, the higher-order structure of human chromosomes, between a few tens and hundreds of nanometers, has not beenmore » well understood. We show a three-dimensional (3D) image of a human prophase nucleus obtained by serial block-face scanning electron microscopy, with 36 of the complete set of 46 chromosomes captured within it. The acquired image allows us to extract quantitative 3D structural information about the nucleus and the preserved, intact individual chromosomes within it, including their positioning and full spatial morphology at a resolution of around 50 nm in three dimensions. The chromosome positions were found, at least partially, to follow the pattern of chromosome territories previously observed only in interphase. The 3D conformation shows parallel, planar alignment of the chromatids, whose occupied volumes are almost fully accounted for by the DNA and known chromosomal proteins. Here, we also propose a potential new method of identifying human chromosomes in three dimensions, on the basis of the measurements of their 3D morphology.« less

  11. Three-dimensional positioning and structure of chromosomes in a human prophase nucleus

    DOE PAGES

    Chen, Bo; Yusuf, Mohammed; Hashimoto, Teruo; ...

    2017-07-21

    The human genetic material is packaged into 46 chromosomes. The structure of chromosomes is known at the lowest level, where the DNA chain is wrapped around a core of eight histone proteins to form nucleosomes. Around a million of these nucleosomes, each about 11 nm in diameter and 6 nm in thickness, are wrapped up into the complex organelle of the chromosome, whose structure is mostly known at the level of visible light microscopy to form a characteristic cross shape in metaphase. However, the higher-order structure of human chromosomes, between a few tens and hundreds of nanometers, has not beenmore » well understood. We show a three-dimensional (3D) image of a human prophase nucleus obtained by serial block-face scanning electron microscopy, with 36 of the complete set of 46 chromosomes captured within it. The acquired image allows us to extract quantitative 3D structural information about the nucleus and the preserved, intact individual chromosomes within it, including their positioning and full spatial morphology at a resolution of around 50 nm in three dimensions. The chromosome positions were found, at least partially, to follow the pattern of chromosome territories previously observed only in interphase. The 3D conformation shows parallel, planar alignment of the chromatids, whose occupied volumes are almost fully accounted for by the DNA and known chromosomal proteins. Here, we also propose a potential new method of identifying human chromosomes in three dimensions, on the basis of the measurements of their 3D morphology.« less

  12. The Biological Effects of Quadripolar Radiofrequency Sequential Application: A Human Experimental Study

    PubMed Central

    Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-01-01

    Abstract Objective: An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Background data: Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. Methods: The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. Results: The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Conclusions: Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening. PMID:25244081

  13. The biological effects of quadripolar radiofrequency sequential application: a human experimental study.

    PubMed

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-10-01

    An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.

  14. Protective Effect of Proanthocyanidins from Sea Buckthorn (Hippophae Rhamnoides L.) Seed against Visible Light-Induced Retinal Degeneration in Vivo.

    PubMed

    Wang, Yong; Zhao, Liang; Huo, Yazhen; Zhou, Feng; Wu, Wei; Lu, Feng; Yang, Xue; Guo, Xiaoxuan; Chen, Peng; Deng, Qianchun; Ji, Baoping

    2016-05-02

    Dietary proanthocyanidins (PACs) as health-protective agents have become an important area of human nutrition research because of their potent bioactivities. We investigated the retinoprotective effects of PACs from sea buckthorn (Hippophae rhamnoides L.) seed against visible light-induced retinal degeneration in vivo. Pigmented rabbits were orally administered sea buckthorn seed PACs (50 and 100 mg/kg/day) for 14 consecutive days of pre-illumination and seven consecutive days of post-illumination. Retinal function was quantified via electroretinography 7 days after light exposure. Retinal damage was evaluated by measuring the thickness of the full-thickness retina and outer nuclear layer 7 days after light exposure. Sea buckthorn seed PACs significantly attenuated the destruction of electroretinograms and maintained the retinal structure. Increased retinal photooxidative damage was expressed by the depletion of glutathione peroxidase and catalase activities, the decrease of total antioxidant capacity level and the increase of malondialdehyde level. Light exposure induced a significant increase of inflammatory cytokines (IL-1β, TNF-α and IL-6) and angiogenesis (VEGF) levels in retina. Light exposure upregulated the expression of pro-apoptotic proteins Bax and caspase-3 and downregulated the expression of anti-apoptotic protein Bcl-2. However, sea buckthorn seed PACs ameliorated these changes induced by light exposure. Sea buckthorn seed PACs mediated the protective effect against light-induced retinal degeneration via antioxidant, anti-inflammatory and antiapoptotic mechanisms.

  15. Protective Effect of Proanthocyanidins from Sea Buckthorn (Hippophae Rhamnoides L.) Seed against Visible Light-Induced Retinal Degeneration in Vivo

    PubMed Central

    Wang, Yong; Zhao, Liang; Huo, Yazhen; Zhou, Feng; Wu, Wei; Lu, Feng; Yang, Xue; Guo, Xiaoxuan; Chen, Peng; Deng, Qianchun; Ji, Baoping

    2016-01-01

    Dietary proanthocyanidins (PACs) as health-protective agents have become an important area of human nutrition research because of their potent bioactivities. We investigated the retinoprotective effects of PACs from sea buckthorn (Hippophae rhamnoides L.) seed against visible light-induced retinal degeneration in vivo. Pigmented rabbits were orally administered sea buckthorn seed PACs (50 and 100 mg/kg/day) for 14 consecutive days of pre-illumination and seven consecutive days of post-illumination. Retinal function was quantified via electroretinography 7 days after light exposure. Retinal damage was evaluated by measuring the thickness of the full-thickness retina and outer nuclear layer 7 days after light exposure. Sea buckthorn seed PACs significantly attenuated the destruction of electroretinograms and maintained the retinal structure. Increased retinal photooxidative damage was expressed by the depletion of glutathione peroxidase and catalase activities, the decrease of total antioxidant capacity level and the increase of malondialdehyde level. Light exposure induced a significant increase of inflammatory cytokines (IL-1β, TNF-α and IL-6) and angiogenesis (VEGF) levels in retina. Light exposure upregulated the expression of pro-apoptotic proteins Bax and caspase-3 and downregulated the expression of anti-apoptotic protein Bcl-2. However, sea buckthorn seed PACs ameliorated these changes induced by light exposure. Sea buckthorn seed PACs mediated the protective effect against light-induced retinal degeneration via antioxidant, anti-inflammatory and antiapoptotic mechanisms. PMID:27144578

  16. A novel method for visualising and quantifying through-plane skin layer deformations.

    PubMed

    Gerhardt, L-C; Schmidt, J; Sanz-Herrera, J A; Baaijens, F P T; Ansari, T; Peters, G W M; Oomens, C W J

    2012-10-01

    Skin is a multilayer composite and exhibits highly non-linear, viscoelastic, anisotropic material properties. In many consumer product and medical applications (e.g. during shaving, needle insertion, patient re-positioning), large tissue displacements and deformations are involved; consequently large local strains in the skin tissue can occur. Here, we present a novel imaging-based method to study skin deformations and the mechanics of interacting skin layers of full-thickness skin. Shear experiments and real-time video recording were combined with digital image correlation and strain field analysis to visualise and quantify skin layer deformations during dynamic mechanical testing. A global shear strain of 10% was applied to airbrush-patterned porcine skin (thickness: 1.2-1.6mm) using a rotational rheometer. The recordings were analysed with ARAMIS image correlation software, and local skin displacement, strain and stiffness profiles through the skin layers determined. The results of this pilot study revealed inhomogeneous skin deformation, characterised by a gradual transition from a low (2.0-5.0%; epidermis) to high (10-22%; dermis) shear strain regime. Shear moduli ranged from 20 to 130kPa. The herein presented method will be used for more extended studies on viable human skin, and is considered a valuable foundation for further development of constitutive models which can be used in advanced finite element analyses of skin. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. In situ measurement of radioactive contamination of bottom sediments.

    PubMed

    Zhukouski, A; Anshakou, O; Kutsen, S

    2018-04-30

    A gamma spectrometric method is presented for in situ radiation monitoring of bottom sediments with contaminated layer of unknown thickness to be determined. The method, based on the processing of experimental spectra using the results of their simulation by the Monte Carlo method, is proposed and tested in practice. A model for the transport of gamma radiation from deposited radionuclides 137 Cs and 134 Cs to a scintillation detection unit located on the upper surface of the contaminated layer of sediments is considered. The relationship between the effective radius of the contaminated site and the thickness of the layer has been studied. The thickness of the contaminated layer is determined by special analysis of experimental and thickness-dependent simulated spectra. The technique and algorithm developed are verified as a result of full-scale studies performed with the submersible gamma-spectrometer. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. The pain of altruism.

    PubMed

    Finlay, Barbara L; Syal, Supriya

    2014-12-01

    Sociality and cooperation are benefits to human cultures but may carry unexpected costs. We suggest that both the human experience of pain and the expression of distress may result from many causes not experienced as painful in our close primate relatives, because human ancestors motivated to ask for help survived in greater numbers than either the thick-skinned or the stoic. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Non-clinical development of CER-001.

    PubMed

    Barbaras, Ronald

    2015-01-01

    Cardiovascular disease remains the most pressing healthcare issue for the developed world and is becoming so for developing countries. There are no currently approved therapies that can rapidly reduce the burden of unstable, inflamed plaque in the overall coronary vascular bed. High-density lipoprotein (HDL) has multiple actions that could lead to plaque stabilization, such as rapid removal of large quantities of cholesterol from the vasculature through the process of reverse lipid transport, improvement in endothelial function, protection against oxidative damage, and reduction in inflammation. Short-term infusion of HDL-mimetics in animal models as well as in humans has shown promising effects on the plaque size and morphology. Cerenis Therapeutics has developed CER-001, a negatively charged lipoprotein complex consisting of phospholipid and recombinant human apoA-I that mimics the structure and function of natural HDL. Three clinical trials using CER-001 infusions have demonstrated improvements in the carotid wall thickness of patients with familial hypercholesterolaemia and in patients with hypo-alphalipoproteinaemia, as well as an impact on coronary plaque burden measured by intravascular ultrasonography at the lowest tested dose (3 mg/kg) in post-ACS patients. Here, we reviewed the non-clinical data leading to the demonstration that CER-001 is a full HDL mimetic.

  20. Empty calories and phantom fullness: a randomized trial studying the relative effects of energy density and viscosity on gastric emptying determined by MRI and satiety.

    PubMed

    Camps, Guido; Mars, Monica; de Graaf, Cees; Smeets, Paul Am

    2016-07-01

    Stomach fullness is a determinant of satiety. Although both the viscosity and energy content have been shown to delay gastric emptying, their relative importance is not well understood. We compared the relative effects of and interactions between the viscosity and energy density on gastric emptying and perceived satiety. A total of 15 healthy men [mean ± SD age: 22.6 ± 2.4 y; body mass index (in kg/m(2)): 22.6 ± 1.8] participated in an experiment with a randomized 2 × 2 crossover design. Participants received dairy-based shakes (500 mL; 50% carbohydrate, 20% protein, and 30% fat) that differed in viscosity (thin and thick) and energy density [100 kcal (corresponding to 0.2 kcal/mL) compared with 500 kcal (corresponding to 1 kcal/mL)]. After ingestion, participants entered an MRI scanner where abdominal scans and oral appetite ratings on a 100-point scale were obtained every 10 min until 90 min after ingestion. From the scans, gastric content volumes were determined. Overall, the gastric emptying half-time (GE t50) was 54.7 ± 3.8 min. The thin 100-kcal shake had the lowest GE t50 of 26.5 ± 3.0 min, followed by the thick 100-kcal shake with a GE t50 of 41 ± 3.9 min and the thin 500-kcal shake with a GE t50 of 69.5 ± 5.9 min, and the thick 500-kcal shake had the highest GE t50 of 81.9 ± 8.3 min. With respect to appetite, the thick 100-kcal shake led to higher fullness (58 points at 40 min) than the thin 500-kcal shake (48 points at 40 min). Our results show that increasing the viscosity is less effective than increasing the energy density in slowing gastric emptying. However, the viscosity is more important to increase the perceived fullness. These results underscore the lack of the satiating efficiency of empty calories in quickly ingested drinks such as sodas. The increase in perceived fullness that is due solely to the increased viscosity, which is a phenomenon that we refer to as phantom fullness, may be useful in lowering energy intake. This trial was registered at www.trialregister.nl as NTR4573. © 2016 American Society for Nutrition.

  1. [The application of full thicknes skin graft inpartial laryngectomy for glottic carcinoma].

    PubMed

    Fu, Y G; Sun, D Z; Yang, P Z; Chen, Y L; Chen, Z P; Yang, Z K

    2016-08-05

    Objective: The aim of this study is to explore the experience and advantages of the application of full thicknes skin graft in glottic carcinoma.partial laryngectomy for glottic carcinoma. Method: One hundred and forty-three patients with glottic cancer were treated with partial laryngectomy.Among those,78 cases were repaired with full-thickness skin graft and 65 cases were repaired with sternohyoid muscular fasciae.Compared the time of extubation and the formation of granulation in laryngeal cavity after operation between the two groups. Result: In the group of full-thickness skin graft,the mean time of decannulation was 6.8 days,5 cases with growth of granulation after operation.In other group,the mean time of decannulation was 10.7 days,16 cases with growth of granulation after operation.The mean time of decannulation( t =-4.739, P <0.01) and the growth of granulation(χ²=9.379, P <0.01) are significantly different between the two groups.No laryngostenosis was found in all patients. Conclusion: The application of full-thicknes skin graft in partial laryngectomy for glottic carcinoma.can shortthe time of extubation and reduce the formation of granulation. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  2. Validation of in vitro assays in three-dimensional human dermal constructs.

    PubMed

    Idrees, Ayesha; Chiono, Valeria; Ciardelli, Gianluca; Shah, Siegfried; Viebahn, Richard; Zhang, Xiang; Salber, Jochen

    2018-05-01

    Three-dimensional cell culture systems are urgently needed for cytocompatibility testing of biomaterials. This work aimed at the development of three-dimensional in vitro dermal skin models and their optimization for cytocompatibility evaluation. Initially "murine in vitro dermal construct" based on L929 cells was generated, leading to the development of "human in vitro dermal construct" consisting of normal human dermal fibroblasts in rat tail tendon collagen type I. To assess the viability of the cells, different assays CellTiter-Blue ® , RealTime-Glo ™ MT, and CellTiter-Glo ® (Promega) were evaluated to optimize the best-suited assay to the respective cell type and three-dimensional system. Z-stack imaging (Live/Dead and Phalloidin/DAPI-Promokine) was performed to visualize normal human dermal fibroblasts inside matrix revealing filopodia-like morphology and a uniform distribution of normal human dermal fibroblasts in matrix. CellTiter-Glo was found to be the optimal cell viability assay among those analyzed. CellTiter-Blue reagent affected the cell morphology of normal human dermal fibroblasts (unlike L929), suggesting an interference with cell biological activity, resulting in less reliable viability data. On the other hand, RealTime-Glo provided a linear signal only with a very low cell density, which made this assay unsuitable for this system. CellTiter-Glo adapted to three-dimensional dermal construct by optimizing the "shaking time" to enhance the reagent penetration and maximum adenosine triphosphate release, indicating 2.4 times higher viability value by shaking for 60 min than for 5 min. In addition, viability results showed that cells were viable inside the matrix. This model would be further advanced with more layers of skin to make a full thickness model.

  3. Estimation of skull table thickness with clinical CT and validation with microCT.

    PubMed

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  4. Evaporation and Hydrocarbon Chain Conformation of Surface Lipid Films.

    PubMed

    Sledge, Samiyyah M; Khimji, Hussain; Borchman, Douglas; Oliver, Alexandria L; Michael, Heidi; Dennis, Emily K; Gerlach, Dylan; Bhola, Rahul; Stephen, Elsa

    2016-10-01

    The inhibition of the rate of evaporation (R evap ) by surface lipids is relevant to reservoirs and dry eye. Our aim was to test the idea that lipid surface films inhibit R evap . R evap were determined gravimetrically. Hydrocarbon chain conformation and structure were measured using a Raman microscope. Six 1-hydroxyl hydrocarbons (11-24 carbons in length) and human meibum were studied. Reflex tears were obtained from a 62-year-old male. The Raman scattering intensity of the lipid film deviated by about 7 % for hydroxyl lipids and varied by 21 % for meibum films across the entire film at a resolution of 5 μm 2 . All of the surface lipids were ordered. R evap of the shorter chain hydroxyl lipids were slightly (7%) but significantly lower compared with the longer chain hydroxyl lipids. R evap of both groups was essentially similar to that of buffer. A hydroxyl lipid film did not influence R evap over an estimated average thickness range of 0.69 to >6.9 μm. R evap of human tears and buffer with and without human meibum (34.4 μm thick) was not significantly different. R evap of human tears was not significantly different from buffer. Human meibum and hydroxyl lipids, regardless of their fluidity, chain length, or thickness did not inhibit R evap of buffer or tears even though they completely covered the surface. It is unlikely that hydroxyl lipids can be used to inhibit R evap of reservoirs. Our data do not support the widely accepted (yet unconfirmed) idea that the tear film lipid layer inhibits R evap of tears. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Preparation of laser micropore porcine acellular dermal matrix for skin graft: an experimental study.

    PubMed

    Chai, Jia-Ke; Liang, Li-Ming; Yang, Hong-Ming; Feng, Rui; Yin, Hui-Nan; Li, Feng-Yu; Sheng, Zhi-Yong

    2007-09-01

    In our previous study, we used composite grafts consisting of meshed porcine acellular dermal matrix (PADM) and thin split-thickness autologous epidermis to cover full thickness burn wounds in clinical practice. However, a certain degree of contraction might occur because the distribution of dermal matrix was not uniform in burn wound. In this study, we prepare a composite skin graft consisting of PADM with the aid of laser to improve the quality of healing of burn wound. PADM was prepared by the trypsin/Triton X-100 method. Micropores were produced on the PADM with a laser punch. The distance between micropores varied from 0.8, 1.0, 1.2 to 1.5mm. Full thickness defect wounds were created on the back of 144 SD rats. The rats were randomly divided into six groups: micropore groups I-IV in which the wound were grafted with PADM with micropores, in four different distances, respectively and split-thickness autograft; mesh group rats received meshed PADM graft and split-thickness autograft; control group received simple split-thickness autografting. The status of wound healing was histologically observed at regular time points after surgery. The wound healing rate and contraction rate were calculated. The wound healing rate in micropore groups I and II was not statistically different from that in control group, but was significantly higher than that in mesh group 6 weeks after grafting. The wound healing rate in micropore groups III and IV was lower than that in mesh and control groups 4 and 6 weeks after grafting. The wound contraction rate in micropore groups I and II was remarkably lower than that in control group 4 and 6 weeks after surgery and it was significantly much lower than that in mesh group 6 weeks after surgery. Histological examination revealed good epithelization, regularly arranged collagenous fibers and integral structure of basement membrane. Laser micropore PADM (0.8 or 1.0mm in distance) grafting in combination with split-thickness autografting can improve wound healing. The PADM with laser micropores in 1.0mm distance is the better choice.

  6. Input impedance of coaxially fed rectangular microstrip antenna on electrically thick substrate

    NASA Technical Reports Server (NTRS)

    Chen, Wei; Lee, Kai-Fong; Lee, R. Q.

    1993-01-01

    A full-wave spectral domain analysis has been used to obtain input-impedance results for a probe-fed rectangular-patch antenna, modeling the source as a magnetic-current frill. Multiple modes are used in the probe surface current to account for axial and azimuthal variations. It is established that maximum resistance is dependent on the substrate loss tangent. The axial variation of the probe current must be taken into account for substrate thicknesses greater than about 0.02 wavelengths.

  7. Fatigue qualification of high thickness composite rotor components

    NASA Astrophysics Data System (ADS)

    Raggi, M.; Mariani, U.; Zaffaroni, G.

    Fatigue qualification aspects of composite rotor components are presented according with the safe life procedure usually applied by helicopter manufacturers. Test activities are identified at three levels of specimen complexity: coupon, structural element and full scale component. Particular attention is given to high thickness laminates qualification as far as environmental exposure is concerned. A practical approach for an accelerated conditioning procedure is described. The application to a main rotor tension link is presented showing the negligible effect of the moisture absorption on its fatigue strength.

  8. Skin graft

    MedlinePlus

    ... that need skin grafts to heal Venous ulcers, pressure ulcers , or diabetic ulcers that do not heal Very ... graft; Full thickness skin graft Patient Instructions Preventing pressure ulcers Surgical wound care - open Images Skin graft Skin ...

  9. Lightning burns.

    PubMed

    Russell, Katie W; Cochran, Amalia L; Mehta, Sagar T; Morris, Stephen E; McDevitt, Marion C

    2014-01-01

    We present the case of a lightning-strike victim. This case illustrates the importance of in-field care, appropriate referral to a burn center, and the tendency of lightning burns to progress to full-thickness injury.

  10. Laser-assisted indocyanine green dye angiography accurately predicts the split-thickness graft timing of integra artificial dermis.

    PubMed

    Fourman, Mitchell S; Phillips, Brett T; Fritz, Jason R; Conkling, Nicole; McClain, Steve A; Simon, Marcia; Dagum, Alexander B

    2014-08-01

    The use of an artificial dermal substitute such as Integra-a bilaminate combination of thin silicone and cross-linked bovine tendon collagen and chondroitin-6-sulfate-has become a popular method to address large surface area wounds or smaller, complex wounds devoid of a vascular bed. The incorporation of Integra depends on a vascular wound bed or periphery and can take 4 weeks or longer to occur. If the Integra has not fully incorporated at the time of placement of the split-thickness graft, complete graft loss may result. The availability of a minimally invasive method to assess the incorporation of Integra would be of great value. Two 5 × 10-cm paraspinal full-thickness wounds were created on 3 female swine. Wounds were randomly assigned full-thickness skin graft or Integra (Plainsboro, NJ) treatment. Both types of grafts were placed after the application of fibrin glue (Tisseel, Deerfield, Ill) to the wound bed. Laser Doppler imaging (LDI) (Moor), indocyanine green dye (ICG) angiography (LifeCell SPY), and clinical scoring were performed weekly for a period of 8 weeks after grafting. At 4 weeks, the silicone layer of the Integra was removed, and a culture of autologous keratinocytes was applied. A 4-mm punch biopsy sample of each graft was taken 1, 2, 4, 6, 7, and 8 weeks postoperatively for histologic analysis. Both ICG angiography and LDI perfusion measurements noted an increase in perfusion at the Integra graft site that peaked 3 weeks after grafting, corresponding with the start of neovascularization and the optimal time for the application of a split-thickness skin graft. indocyanine green dye angiography measurements exhibit greater reproducibility between animals at late time points as compared with LDI. This decrease in LDI precision is directly related to increases in scar tissue thickness of greater than 5 mm as determined via histologic analysis and corresponds with the accepted maximum penetration depth of the LDI laser. Indocyanine green dye angiography may provide valuable information as to graft integrity and split-thickness skin graft timing at late time points. Range of LDI seems to be insufficient for split-thickness graft timing or late time point accuracy. Future exploration of ICG angiography potential will involve tracking Integra graft delay in porcine models.

  11. Comparison of the characteristics in hen and quail corneas as experimental models of refractive surgery.

    PubMed

    Gonçalves, G C; Pérez-Merino, P; Martínez-García, M C; Barcía, A; Merayo-Loves, J

    2016-07-01

    To compare the histological, morphological and the biophysical measurements between hen and quail corneas, in order to determine which of them were better suited for use as an animal model for research into corneal refractive surgery. A study was performed using the biophysical measurements of the cornea (curvature, thickness, refraction, and axial length) of 20 animals (10 hens and 10 quails). The corneas were then prepared for histological analysis under microscopy light. The analysis showed that both groups have the same number of corneal layers as the human cornea and with an evident Bowman's layer. The thickness of the hen cornea and axial length of the eye, 225.3±18.4μm and 12.8±0.25mm, respectively, were larger than that of the quail (P<.01 and P<.001, respectively). The radius of curvature for the hen central cornea, 3.65±0.08mm, was greater than that for the quail (P<.001), but the refractive power of each cornea was similar. The proportion of total corneal thickness of the hen stroma, 82.6%, was more similar to that of the human than was the quail stroma, 72.5%. Within the hen stroma, the density of keratocytes, 8.57±1.49 per 5,000μm(2), was about half that in the quail stroma (P<.005). Because of the large size of the hen cornea, the stromal thickness and proportional similarity of the corneal layers with human cornea, the hen maybe better than the quail as an alternative species suitable for use in studies of corneal refractive surgery. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Development of the penis during the human fetal period (13 to 36 weeks after conception).

    PubMed

    Gallo, Carla B M; Costa, Waldemar S; Furriel, Angelica; Bastos, Ana L; Sampaio, Francisco J B

    2013-11-01

    We analyzed the development of the area of the penis and erectile structures (corpora cavernosa and corpus spongiosum) and the thickness of the tunica albuginea during the fetal period (13 to 36 weeks after conception) in humans to establish normative patterns of growth. We studied 56 male human fetuses at 13 to 36 weeks after conception. We used histochemical and morphometric techniques to analyze the parameters of total penile area, area of corpora cavernosa, area of corpus spongiosum, and thickness of tunica albuginea in the dorsal and ventral regions using ImageJ software (National Institutes of Health, Bethesda, Maryland). Between 13 and 36 weeks after conception the area of the penis varies from 0.95 to 24.25 mm2. The area of the corpora cavernosa varies from 0.28 to 9.12 mm2, and the area of the corpus spongiosum varies from 0.14 to 3.99 mm2. The thickness of the tunica albuginea varies from 0.029 to 0.296 mm in the dorsal region and from 0.014 to 0.113 mm in the ventral region of the corpora cavernosa. We found a strong correlation between the total penile area, corpora cavernosa and corpus spongiosum with fetal age (weeks following conception). The growth rate was more intense during the second trimester (13 to 24 weeks of gestation) compared to the third trimester (25 to 36 weeks). Tunica albuginea thickness also was strongly correlated with fetal age and this structure was thicker in the dorsal vs ventral region. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. The effect of the season of birth and of selected maternal factors on linear enamel thickness in modern human deciduous incisors.

    PubMed

    Żądzińska, E; Kurek, M; Borowska-Strugińska, B; Lorkiewicz, W; Rosset, I; Sitek, A

    2013-08-01

    Development of human tooth enamel is a part of a foetus's development; its correctness is the outcome of genetic and maternal factors shaping its prenatal environment. Many authors reported that individuals born in different seasons experience different early developmental conditions during pregnancy. In this study, we investigated the effects of season of birth and selected maternal factors on enamel thickness of deciduous incisors. Dental sample comprises 60 deciduous incisors. The parents who handed over their children's teeth for research fill in questionnaires containing questions about the course of pregnancy. All teeth were sectioned in the labio-linqual plane using diamond blade (Buechler IsoMet 1000). The final specimens were observed by way of scanning electron microscopy at magnifications 80× and 320×. The thickness of total enamel (TE), prenatally (PE) and postnatally (PSE) formed enamel was measured. Children born in summer and in spring (whose first and second foetal life fall on autumn and winter) have the thinnest enamel. Season of birth, number of children in family, diseases and spasmolytic medicines using by mother during pregnancy explained almost 13% of the variability of TE. Regression analysis proved a significant influence of the season of birth and selected maternal factors on the PE thickness - these factors explained over 17% of its variability. Neither of analysed variables had influenced PSE. Our findings suggests that the thickness of enamel of deciduous incisors depends on the season of birth and some maternal factors. The differences were observed only in the prenatally formed enamel. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. In vivo imaging through the entire thickness of human cornea by full-field optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Mazlin, Viacheslav; Xiao, Peng; Dalimier, Eugénie; Grieve, Kate; Irsch, Kristina; Sahel, José; Fink, Mathias; Boccara, Claude

    2018-02-01

    Despite obvious improvements in visualization of the in vivo cornea through the faster imaging speeds and higher axial resolutions, cellular imaging stays unresolvable task for OCT, as en face viewing with a high lateral resolution is required. The latter is possible with FFOCT, a method that relies on a camera, moderate numerical aperture (NA) objectives and an incoherent light source to provide en face images with a micrometer-level resolution. Recently, we for the first time demonstrated the ability of FFOCT to capture images from the in vivo human cornea1. In the current paper we present an extensive study of appearance of healthy in vivo human corneas under FFOCT examination. En face corneal images with a micrometer-level resolution were obtained from the three healthy subjects. For each subject it was possible to acquire images through the entire corneal depth and visualize the epithelium structures, Bowman's layer, sub-basal nerve plexus (SNP) fibers, anterior, middle and posterior stroma, endothelial cells with nuclei. Dimensions and densities of the structures visible with FFOCT, are in agreement with those seen by other cornea imaging methods. Cellular-level details in the images obtained together with the relatively large field-of-view (FOV) and contactless way of imaging make this device a promising candidate for becoming a new tool in ophthalmological diagnostics.

  15. Spatial frequency domain imaging of burn wounds in a preclinical model of graded burn severity

    NASA Astrophysics Data System (ADS)

    Nguyen, John Quan; Crouzet, Christian; Mai, Tuan; Riola, Kathleen; Uchitel, Daniel; Liaw, Lih-Huei; Bernal, Nicole; Ponticorvo, Adrien; Choi, Bernard; Durkin, Anthony J.

    2013-06-01

    Frequent monitoring of early-stage burns is necessary for deciding optimal treatment and management. Both superficial and full thickness burns are relatively easy to diagnose based on clinical observation. In between these two extremes are superficial-partial thickness and deep-partial thickness burns. These burns, while visually similar, differ dramatically in terms of clinical treatment and are known to progress in severity over time. The objective of this study was to determine the potential of spatial frequency domain imaging (SFDI) for noninvasively mapping quantitative changes in chromophore and optical properties that may be an indicative of burn wound severity. A controlled protocol of graded burn severity was developed and applied to 17 rats. SFDI data was acquired at multiple near-infrared wavelengths over a course of 3 h. Burn severity was verified using hematoxylin and eosin histology. From this study, we found that changes in water concentration (edema), deoxygenated hemoglobin concentration, and optical scattering (tissue denaturation) to be statistically significant at differentiating superficial partial-thickness burns from deep-partial thickness burns.

  16. An investigation on the effect of second-order additional thickness distributions to the upper surface of an NACA 64 sub 1-212 airfoil. [using flow equations and a CDC 7600 digital computer

    NASA Technical Reports Server (NTRS)

    Hague, D. S.; Merz, A. W.

    1975-01-01

    An investigation was conducted on a CDC 7600 digital computer to determine the effects of additional thickness distributions to the upper surface of an NACA 64 sub 1 - 212 airfoil. Additional thickness distributions employed were in the form of two second-order polynomial arcs which have a specified thickness at a given chordwise location. The forward arc disappears at the airfoil leading edge, the aft arc disappears at the airfoil trailing edge. At the juncture of the two arcs, x = x, continuity of slope is maintained. The effect of varying the maximum additional thickness and its chordwise location on airfoil lift coefficient, pitching moment, and pressure distribution was investigated. Results were obtained at a Mach number of 0.2 with an angle-of-attack of 6 degrees on the basic NACA 64 sub 1 - 212 airfoil, and all calculations employ the full potential flow equations for two dimensional flow. The relaxation method of Jameson was employed for solution of the potential flow equations.

  17. An investigation on the effect of second-order additional thickness distributions to the upper surface of an NACA 64-206 airfoil. [using flow equations and a CDC 7600 digital computer

    NASA Technical Reports Server (NTRS)

    Merz, A. W.; Hague, D. S.

    1975-01-01

    An investigation was conducted on a CDC 7600 digital computer to determine the effects of additional thickness distributions to the upper surface of an NACA 64-206 airfoil. Additional thickness distributions employed were in the form of two second-order polynomial arcs which have a specified thickness at a given chordwise location. The forward arc disappears at the airfoil leading edge, the aft arc disappears at the airfoil trailing edge. At the juncture of the two arcs, x = x, continuity of slope is maintained. The effect of varying the maximum additional thickness and its chordwise location on airfoil lift coefficient, pitching moment, and pressure distribution was investigated. Results were obtained at a Mach number of 0.2 with an angle-of-attack of 6 degrees on the basic NACA 64-206 airfoil, and all calculations employ the full potential flow equations for two dimensional flow. The relaxation method of Jameson was employed for solution of the potential flow equations.

  18. Comparison of Ganglion Cell and Retinal Nerve Fiber Layer Thickness in Pigment Dispersion Syndrome, Pigmentary Glaucoma, and Healthy Subjects with Spectral-domain OCT.

    PubMed

    Arifoglu, Hasan Basri; Simavli, Huseyin; Midillioglu, Inci; Berk Ergun, Sule; Simsek, Saban

    2017-01-01

    To evaluate the ganglion cell complex (GCC) and retinal nerve fiber layer (RNFL) thickness in pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG) with RTVue spectral domain optical coherence tomography (SD-OCT). A total of 102 subjects were enrolled: 29 with PDS, 18 with PG, and 55 normal subjects. Full ophthalmic examination including visual field analysis was performed. SD-OCT was used to analyze GCC superior, GCC inferior, and average RNFL thickness. To compare the discrimination capabilities, the areas under the receiver operating characteristic curves were assessed. Superior GCC, inferior GCC, and RNFL thickness values of patients with PG were statistically signicantly lower than those of patients with PDS (p < 0.001) and healthy individuals (p < 0.001 for all). No statistically significant difference was found between PDS and normal subjects in same parameters (p > 0.05). The SD-OCT-derived GCC and RNFL thickness parameters can be useful to discriminate PG from both PDS and normal subjects.

  19. Experience With Intravascular Ultrasound Imaging Of Human Atherosclerotic Arteries

    NASA Astrophysics Data System (ADS)

    Mallery, John A.; Gessert, James M.; Maciel, Mario; Tobis, John M.; Griffith, James M.; Berns, Michael W.; Henry, Walter L.

    1989-08-01

    Normal human arteries have a well-defined structure on intravascular images. The intima appears very thin and is most likely represented by a bright reflection arising from the internal elastic lamina. The smooth muscle tunica media is echo-lucent on the ultrasound image and appears as a dark band separating the intima from the adventitia. The adventitia is a brightly reflective layer of variable thickness. The thickness of the intima, and therefore of the atherosclerotic plaque can be accurately measured from the ultrasound images and correlates well with histology. Calcification within the wall of arteries is seen as bright echo reflection with shadowing of the peripheral wall. Fibrotic regions are highly reflective but do not shadow. Necrotic liquid regions within advanced atherosclerotic plaques are seen on ultrasound images as large lucent zones surrounded by echogenic tissue. Imaging can be performed before and after interventional procedures, such as laser angioplasty, balloon angioplasty and atherectomy. Intravascular ultrasound appears to provide an imaging modality for identifying the histologic characteristics of diseased arteries and for quantifying plaque thickness. It might be possible to perform such quantification to evaluate the results of interventional procedures.

  20. Fluorescence multispectral imaging-based diagnostic system for atherosclerosis.

    PubMed

    Ho, Cassandra Su Lyn; Horiuchi, Toshikatsu; Taniguchi, Hiroaki; Umetsu, Araya; Hagisawa, Kohsuke; Iwaya, Keiichi; Nakai, Kanji; Azmi, Amalina; Zulaziz, Natasha; Azhim, Azran; Shinomiya, Nariyoshi; Morimoto, Yuji

    2016-08-20

    Composition of atherosclerotic arterial walls is rich in lipids such as cholesterol, unlike normal arterial walls. In this study, we aimed to utilize this difference to diagnose atherosclerosis via multispectral fluorescence imaging, which allows for identification of fluorescence originating from the substance in the arterial wall. The inner surface of extracted arteries (rabbit abdominal aorta, human coronary artery) was illuminated by 405 nm excitation light and multispectral fluorescence images were obtained. Pathological examination of human coronary artery samples were carried out and thickness of arteries were calculated by measuring combined media and intima thickness. The fluorescence spectra in atherosclerotic sites were different from those in normal sites. Multiple regions of interest (ROI) were selected within each sample and a ratio between two fluorescence intensity differences (where each intensity difference is calculated between an identifier wavelength and a base wavelength) from each ROI was determined, allowing for discrimination of atherosclerotic sites. Fluorescence intensity and thickness of artery were found to be significantly correlated. These results indicate that multispectral fluorescence imaging provides qualitative and quantitative evaluations of atherosclerosis and is therefore a viable method of diagnosing the disease.

  1. Fluid Structural Analysis of Human Cerebral Aneurysm Using Their Own Wall Mechanical Properties

    PubMed Central

    Valencia, Alvaro; Burdiles, Patricio; Ignat, Miguel; Mura, Jorge; Rivera, Rodrigo; Sordo, Juan

    2013-01-01

    Computational Structural Dynamics (CSD) simulations, Computational Fluid Dynamics (CFD) simulation, and Fluid Structure Interaction (FSI) simulations were carried out in an anatomically realistic model of a saccular cerebral aneurysm with the objective of quantifying the effects of type of simulation on principal fluid and solid mechanics results. Eight CSD simulations, one CFD simulation, and four FSI simulations were made. The results allowed the study of the influence of the type of material elements in the solid, the aneurism's wall thickness, and the type of simulation on the modeling of a human cerebral aneurysm. The simulations use their own wall mechanical properties of the aneurysm. The more complex simulation was the FSI simulation completely coupled with hyperelastic Mooney-Rivlin material, normal internal pressure, and normal variable thickness. The FSI simulation coupled in one direction using hyperelastic Mooney-Rivlin material, normal internal pressure, and normal variable thickness is the one that presents the most similar results with respect to the more complex FSI simulation, requiring one-fourth of the calculation time. PMID:24151523

  2. Effects of Preoperative Local Estrogen in Postmenopausal Women With Prolapse: A Randomized Trial

    PubMed Central

    Good, Meadow M.; Roshanravan, Shayzreen M.; Shi, Haolin; Schaffer, Joseph I.; Singh, Ravinder J.; Word, R. Ann

    2014-01-01

    Context: Pelvic organ prolapse (POP) increases in prevalence with age; recurrence after surgical repair is common. Objective: The objective of the study was to determine the effects of local estrogen treatment on connective tissue synthesis and breakdown in the vaginal wall of postmenopausal women planning surgical repair of POP. Design: This was a randomized trial. Setting: The study was conducted at an academic tertiary medical center. Patients or Other Participants: Postmenopausal women with a uterus and symptomatic anterior and/or apical prolapse at stage 2 or greater participated in the study. Intervention: Estrogen (Premarin) or placebo cream for 6 weeks preoperatively was the intervention. Main Outcome Measures: Full-thickness anterior apical vaginal wall biopsies were obtained at the time of hysterectomy and analyzed for mucosa and muscularis thickness, connective tissue synthesis, and degradation. Serum levels of estrone and 17β-estradiol were analyzed at baseline and the day of surgery using highly sensitive liquid chromatography-tandem mass spectrometry. Results: Fifteen women per group (n = 30 total) were randomized; 13 per group underwent surgery. Among drug-adherent participants (n = 8 estrogen, n = 13 placebo), epithelial and muscularis thickness was increased 1.8- and 2.7-fold (P = .002 and P =.088, respectively) by estrogen. Collagen types 1α1 and 1α2 mRNA increased 6.0- and 1.8-fold in the vaginal muscularis (P < .05 for both); collagen type Ia protein increased 9-fold in the muscularis (P = .012), whereas collagen III was not changed significantly. MMP-12 (human macrophage elastase) mRNA was suppressed in the vaginal mucosa from estrogen-treated participants (P = .011), and matrix metalloprotease-9 activity was decreased 6-fold in the mucosa and 4-fold in the muscularis (P = .02). Consistent with menopausal norms, serum estrone and 17β-estradiol were low and did not differ among the two groups. Conclusions: Vaginal estrogen application for 6 weeks preoperatively increased synthesis of mature collagen, decreased degradative enzyme activity, and increased thickness of the vaginal wall, suggesting this intervention improves both the substrate for suture placement at the time of surgical repair and maintenance of connective tissue integrity of the pelvic floor. PMID:24947034

  3. On the use of Orbscan II to assess the peripheral corneal thickness in humans: a comparison with ultrasound pachometry measures.

    PubMed

    Jonuscheit, Sven; Doughty, Michael J; Button, Norman F

    2007-03-01

    To compare the measures of corneal thickness measurements obtained by an optical scanning slit method with those obtained by an ultrasound (US) pachometer, with special interest in the mid-peripheral (2.5 mm from centre) and peripheral (4.5 mm from centre) region of the cornea. Three measures of corneal thickness were taken using Orbscan II and then by US pachometry (under topical anaesthesia with benoxinate 0.4%) on 24 adults, aged 20-58 years and with up to 8.5 D of myopia. The full Orbscan topography maps were used to extract single point data along the horizontal corneal meridian for the geometric centre, 2.5 mm from centre (nasal and temporal) and 4.5 mm (nasal and temporal) from centre. No correction factor was used for the Orbscan data. The same set of measures were made with the US pachometer. In all cases, the averages of three (centre) or six (mid-periphery and periphery) readings were taken as the measurements from each cornea. Orbscan readings on the right eyes averaged 0.576, 0.632 and 0.712 mm for central, mid-peripheral and peripheral sites with average values for emmetropic subjects (<1 DS, n = 12) being marginally higher than for myopic subjects (average - 4.00 DS, n = 12). For US pachometry, the average values were however 0.522, 0.554 and 0.606 mm. Similar results were obtained on left eyes. Combining data from both eyes also showed that the mean difference between Orbscan II and US measures was not constant across the cornea, being 0.055 +/- 0.014 mm at the centre, 0.080 +/- 0.019 mm at mid-peripheral locations and 0.107 +/- 0.046 mm at the peripheral sites. These differences persisted after application of the generally recommended acoustic factor (x0.92) to all of the Orbscan readings. A single acoustic factor correction cannot be applied to all corneal thickness measures made with an Orbscan II to equate the measures to those made with an US pachometer.

  4. Practice-Near and Practice-Distant Methods in Human Services Research

    ERIC Educational Resources Information Center

    Froggett, Lynn; Briggs, Stephen

    2012-01-01

    This article discusses practice-near research in human services, a cluster of methodologies that may include thick description, intensive reflexivity, and the study of emotional and relational processes. Such methods aim to get as near as possible to experiences at the relational interface between institutions and the practice field.…

  5. Structural investigations of human hairs by spectrally resolved ellipsometry

    NASA Astrophysics Data System (ADS)

    Schulz, Benjamin; Chan, D.; Ruebhausen, M.; Wessel, S.; Wepf, R.

    2006-03-01

    Human hair is a biological layered system composed of two major layers, the cortex and the cuticle. We show spectrally resolved ellipsometry measurements of the ellipsometric parameters ψ and δ of single human hairs. The spectra reflect the layered nature of hair and the optical anisotropy of the hair’s structure. In addition, measurements on strands of human hair show a high reproducibility of the ellipsometric parameters for different hair fiber bundles from the same person. Based on the measurements, we develop a model of the dielectric function of hair that explains the spectra. This model includes the dielectric properties of the cuticle and cortex as well as their associated layer thicknesses. In addition, surface roughness effects modelled by a roughness layer with an complex refractive index given by an effective medium approach can have a significant effect on the measurements. We derive values for the parameters of the cuticle surface roughness layer of the thickness dACu= 273-360 nm and the air inclusion fA= 0.6 -5.7%. [1] accepted for publication in J. Biomed Opt., 2005

  6. A grating coupler with a trapezoidal hole array for perfectly vertical light coupling between optical fibers and waveguides

    NASA Astrophysics Data System (ADS)

    Mizutani, Akio; Eto, Yohei; Kikuta, Hisao

    2017-12-01

    A grating coupler with a trapezoidal hole array was designed and fabricated for perfectly vertical light coupling between a single-mode optical fiber and a silicon waveguide on a silicon-on-insulator (SOI) substrate. The grating coupler with an efficiency of 53% was computationally designed at a 1.1-µm-thick buried oxide (BOX) layer. The grating coupler and silicon waveguide were fabricated on the SOI substrate with a 3.0-µm-thick BOX layer by a single full-etch process. The measured coupling efficiency was 24% for TE-polarized light at 1528 nm wavelength, which was 0.69 times of the calculated coupling efficiency for the 3.0-µm-thick BOX layer.

  7. Material and Thickness Grading for Aeroelastic Tailoring of the Common Research Model Wing Box

    NASA Technical Reports Server (NTRS)

    Stanford, Bret K.; Jutte, Christine V.

    2014-01-01

    This work quantifies the potential aeroelastic benefits of tailoring a full-scale wing box structure using tailored thickness distributions, material distributions, or both simultaneously. These tailoring schemes are considered for the wing skins, the spars, and the ribs. Material grading utilizes a spatially-continuous blend of two metals: Al and Al+SiC. Thicknesses and material fraction variables are specified at the 4 corners of the wing box, and a bilinear interpolation is used to compute these parameters for the interior of the planform. Pareto fronts detailing the conflict between static aeroelastic stresses and dynamic flutter boundaries are computed with a genetic algorithm. In some cases, a true material grading is found to be superior to a single-material structure.

  8. Cellular Therapy With Human Autologous Adipose-Derived Adult Stem Cells for Advanced Keratoconus.

    PubMed

    Alió Del Barrio, Jorge L; El Zarif, Mona; de Miguel, María P; Azaar, Albert; Makdissy, Norman; Harb, Walid; El Achkar, Ibrahim; Arnalich-Montiel, Francisco; Alió, Jorge L

    2017-08-01

    The aim of this phase 1 study was to preliminarily evaluate the safety and efficacy of autologous adipose-derived adult stem cell (ADASC) implantation within the corneal stroma of patients with advanced keratoconus. Five consecutive patients were selected. Autologous ADASCs were obtained by elective liposuction. ADASCs (3 × 10) contained in 1 mL saline were injected into the corneal stroma through a femtosecond-assisted 9.5-mm diameter lamellar pocket under topical anesthesia. Patients were reviewed at 1 day, 1 week, 1, 3, and 6 months postoperatively. Visual function, manifest refraction, slit-lamp biomicroscopy, intraocular pressure, endothelial cell density, corneal topography, corneal optical coherence tomography, and corneal confocal biomicroscopy were recorded. No intraoperative or postoperative complications were recorded, with full corneal transparency recovery within 24 hours. Four patients completed the full follow-up. All patients improved their visual function (mean: 1 line of unaided and spectacle-corrected distance vision and 2 lines of rigid contact lens distance vision). Manifest refraction and topographic keratometry remained stable. Corneal optical coherence tomography showed a mean improvement of 16.5 μm in the central corneal thickness, and new collagen production was observed as patchy hyperreflective areas at the level of the stromal pocket. Confocal biomicroscopy confirmed the survival of the implanted stem cells at the surgical plane. Intraocular pressure and endothelial cell density remained stable. Cellular therapy of the human corneal stroma in vivo with autologous ADASCs appears to be safe. Stem cells survive in vivo with intrastromal new collagen production. Future studies with larger samples are required to confirm these preliminary results.

  9. Facial soft tissue thickness in skeletal type I Japanese children.

    PubMed

    Utsuno, Hajime; Kageyama, Toru; Deguchi, Toshio; Umemura, Yasunobu; Yoshino, Mineo; Nakamura, Hiroshi; Miyazawa, Hiroo; Inoue, Katsuhiro

    2007-10-25

    Facial reconstruction techniques used in forensic anthropology require knowledge of the facial soft tissue thickness of each race if facial features are to be reconstructed correctly. If this is inaccurate, so also will be the reconstructed face. Knowledge of differences by age and sex are also required. Therefore, when unknown human skeletal remains are found, the forensic anthropologist investigates for race, sex, and age, and for other variables of relevance. Cephalometric X-ray images of living persons can help to provide this information. They give an approximately 10% enlargement from true size and can demonstrate the relationship between soft and hard tissue. In the present study, facial soft tissue thickness in Japanese children was measured at 12 anthropological points using X-ray cephalometry in order to establish a database for facial soft tissue thickness. This study of both boys and girls, aged from 6 to 18 years, follows a previous study of Japanese female children only, and focuses on facial soft tissue thickness in only one skeletal type. Sex differences in thickness of tissue were found from 12 years of age upwards. The study provides more detailed and accurate measurements than past reports of facial soft tissue thickness, and reveals the uniqueness of the Japanese child's facial profile.

  10. Daily morning light therapy is associated with an increase in choroidal thickness in healthy young adults.

    PubMed

    Read, Scott A; Pieterse, Emily C; Alonso-Caneiro, David; Bormann, Rebekah; Hong, Seentinie; Lo, Chai-Hoon; Richer, Rhiannon; Syed, Atif; Tran, Linda

    2018-05-29

    Ambient light exposure is one environmental factor thought to play a role in the regulation of eye growth and refractive error development, and choroidal thickness changes have also been linked to longer term changes in eye growth. Therefore in this study we aimed to examine the influence of a 1-week period of morning light therapy upon choroidal thickness. Twenty two healthy young adult subjects had a series of macular choroidal thickness measurements collected with spectral domain optical coherence tomography before, and then following a 7-day period of increased daily light exposure. Increased light exposure was delivered through the use of commercially available light therapy glasses, worn for 30 minutes in the morning each day. A significant increase in subfoveal choroidal thickness (mean increase of +5.4 ± 10.3 µm) was found following 7-days of increased daily light exposure (p = 0.02). An increase in choroidal thickness was also observed associated with light therapy across the central 5 mm macular region. This study provides the first evidence in the human eye that daily morning light therapy results in small magnitude but statistically significant increases in choroidal thickness. These changes may have implications for our understanding of the impact of environmental factors upon eye growth.

  11. Histological case-control study of peeling-induced skin changes by different peeling agents in surgically subcutaneous undermined skin flaps in facelift patients.

    PubMed

    Gonser, P; Kaestner, S; Jaminet, P; Kaye, K

    2017-11-01

    A histological evaluation of peeling-induced skin changes in subcutaneous undermined preauricular facial skin flaps of nine patients was performed. There were three treatment groups: Trichloroacetic acid (TCA) 25%, TCA 40% and phenol/croton oil; one group served as control. Two independent evaluators determined the epidermal and dermal thickness and the depth of necrosis (micrometre). The percentual tissue damage due to the peeling was calculated, and a one-sample t-test for statistical significance was performed. On the basis of the histomorphological changes, peeling depth was classified as superficial, superficial-partial, deep-partial and full thickness chemical burn. The histological results revealed a progression of wound depth for different peeling agents without full thickness necrosis. TCA peels of up to 40% can be safely applied on subcutaneous undermined facial skin flaps without impairing the vascular patency, producing a predictable chemical burn, whereas deep peels such as phenol/croton oil peels should not be applied on subcutaneous undermined skin so as to not produce skin slough or necrosis by impairing vascular patency. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Sinusitis Q and A

    MedlinePlus

    ... such as thickened nasal drainage, nasal congestion and facial pain or pressure . Because sinusitis is often preceded by, ... drainage that is thick and discolored, or purulent Facial pain, pressure, or fullness, that often affects the cheeks, ...

  13. Classification of full-thickness rotator cuff lesions: a review

    PubMed Central

    Lädermann, Alexandre; Burkhart, Stephen S.; Hoffmeyer, Pierre; Neyton, Lionel; Collin, Philippe; Yates, Evan; Denard, Patrick J.

    2016-01-01

    Rotator cuff lesions (RCL) have considerable variability in location, tear pattern, functional impairment, and repairability. Historical classifications for differentiating these lesions have been based upon factors such as the size and shape of the tear, and the degree of atrophy and fatty infiltration. Additional recent descriptions include bipolar rotator cuff insufficiency, ‘Fosbury flop tears’, and musculotendinous lesions. Recommended treatment is based on the location of the lesion, patient factors and associated pathology, and often includes personal experience and data from case series. Development of a more comprehensive classification which integrates historical and newer descriptions of RCLs may help to guide treatment further. Cite this article: Lädermann A, Burkhart SS, Hoffmeyer P, et al. Classification of full thickness rotator cuff lesions: a review. EFORT Open Rev 2016;1:420-430. DOI: 10.1302/2058-5241.1.160005. PMID:28461921

  14. Ocriplasmin: who is the best candidate?

    PubMed Central

    Prospero Ponce, Claudia M; Stevenson, William; Gelman, Rachel; Agarwal, Daniel R; Christoforidis, John B

    2016-01-01

    Enzymatic vitreolysis is currently the focus of attention around the world for treating vitreomacular traction and full-thickness macular hole. Induction of posterior vitreous detachment is an active area of developmental clinical and basic research. Despite exerting an incompletely elucidated physiological effect, ocriplasmin (also known as microplasmin) has been recognized to serve as a well-tolerated intravitreal injection for the treatment of vitreomacular traction and full-thickness macular hole. There are several unexplored areas of intervention where enzymatic vitreolysis could potentially be used (ie, diabetic macular edema). Recent promising studies have included combinations of enzymatic approaches and new synthetic molecules that induce complete posterior vitreous detachment as well as antiangiogenesis. Although no guidelines have been proposed for the use of ocriplasmin, this review attempts to aid physicians in answering the most important question, “Who is the best candidate?” PMID:27051270

  15. Full-Thickness Macular Hole Formation in the Postoperative Period After Initial Vitrectomy for Rhegmatogenous Retinal Detachment.

    PubMed

    Takashina, Hirotsugu; Watanabe, Akira; Tsuneoka, Hiroshi

    2017-01-01

    To evaluate full-thickness macular hole (MH) formation in the postoperative period after initial vitrectomy for rhegmatogenous retinal detachment (rRD). We retrospectively reviewed the medical records of 4 consecutive eyes that required additional vitrectomy for full-thickness MH between April 2013 and March 2016 after undergoing an initial vitrectomy for rRD. Epiretinal membrane (ERM) was identified by preoperative optical coherence tomography or intraoperative dye staining in each case. Photocoagulation of retinal breaks prior to initial vitrectomy was performed in Cases 1, 2, and 3 (4-16 days), with yttrium-aluminum-garnet capsulotomy after cataract extraction also performed prior to the retinal break formation in Case 3. At the initial vitrectomy, there was a superior retinal break which crossed the equator in Case 2, and an intentional hole was created in Cases 1 and 4. The mean interval from the initial vitrectomy until MH formation was 27.5 ± 15.8 months. As with Case 2, the intervals in Cases 1 and 4, in which an intentional hole was created, were clearly shorter than in those in Case 3. Finally, MH closure was achieved after an additional vitrectomy (removal of the internal limiting membrane with ERM and gas tamponade) and best-corrected visual acuity improved in each case. ERM was identified in the cases examined in our study. The presence of an intentional hole might shorten the interval of MH formation after vitrectomy for rRD.

  16. Construction strength analysis of landing craft tank conversion to passenger ship using finite element method

    NASA Astrophysics Data System (ADS)

    Nurul Misbah, Mohammad; Setyawan, Dony; Murti Dananjaya, Wisnu

    2018-03-01

    This research aims to determine the longitudinal strength of passenger ship which was converted from Landing Craft Tank with 54 m of length as stated by BKI (Biro Klasifikasi Indonesia / Indonesian Classification Bureau). Verification of strength value is done to 4 (four) loading conditions which are (1) empty load condition during sagging wave, (2) empty load condition during hogging wave, (3) full load condition during sagging wave and (4) full load condition during hogging wave. Analysis is done using Finite Element Analysis (FEA) software by modeling the entire part of passenger ship and its loading condition. The back and upfront part of ship centerline were used as the boundary condition. From that analysis it can be concluded that the maximum stress for load condition (1) is 72,393 MPa, 74,792 MPa for load condition (2), 129,92 MPa for load condition (3), and 132,4 MPa for load condition (4). Longitudinal strength of passenger ship fulfilled the criteria of empty load condition having smaller stress value than allowable stress which is 90 MPa, and during full load condition with smaller stress value than allowable stress which is 150 MPa. Analysis on longitudinal strength comparison with entire ship plate thickness variation of ± 2 mm from initial plate was also done during this research. From this research it can be concluded that plate thickness reduction causes the value of longitudinal strength to decrease, while plate thickness addition causes the value of longitudinal strength to increase.

  17. Major burn injuries associated with Christmas celebrations: a 41-year experience from Switzerland

    PubMed Central

    Rohrer-Mirtschink, S.; Forster, N.; Giovanoli, P.; Guggenheim, M.

    2015-01-01

    Summary In Switzerland it is customary to light candles on Christmas trees and advent wreaths. This tradition leads to an increased risk of home fires. We reviewed the records of patients who sustained burn injuries from a lit Christmas tree or advent wreath during the Christmas holidays between January 1971 and January 2012. We treated 28 patients and observed 4 fatalities (mortality rate: 14%). 61% of the patients were male, 39% were female. The mean abbreviated burn severity index (ABSI) was 6.5 points in the group of the survivors and 10.8 points in the group of the non-survivors. The mean total body surface area burned (TBSA) for survivors was 18.9%, with 14.1% having full thickness burns; for the non-survivors the mean TBSA was 45.2%, with 38% having full thickness burns. The Mann-Whitney U-test showed a significant difference between the survivors and the fatalities concerning the mean total and full thickness burned body surface area (p value 0.009 and 0.012). More than sixty percent of the fires occurred in January and the most severe accidents were seen after January 4th. Despite Christmas decoration-associated fires being relatively uncommon, they tend to cause more serious injuries than regular household fires. We recommend that in countries where it is customary to set up flammable Christmas decorations, state-issued information pamphlets with instructions on fire safety conduct should be distributed. PMID:26668566

  18. Microincision, aspiration cutter-assisted multifocal iris biopsy for melanoma.

    PubMed

    Finger, Paul T; Milman, Tatyana

    2017-01-19

    To describe a minimally invasive method to create multifocal full-thickness surgical iridectomy biopsies. Seven patients suspected to have diffuse iris melanoma underwent multifocal surgical iridectomy biopsy through a single 1.0-mm clear corneal incision. A 25-G inked trocar was used to create one visible corneal portal, through which the anterior chamber was filled with sodium hyaluronate 1%. Then, a 25-G aspiration cutter probe was introduced through the corneal incision such that the aspiration portal was occluded by the iris biopsy sites. Then aspiration (600 mm Hg) cutting (300 cuts per minute) was used to create full- and partial-thickness surgical iridectomy biopsies at multiple locations. After each biopsy the probe was removed, and its contents aspirated into a separate 3-mL syringe (marked by clock hour location). The sodium hyaluronate 1% was removed and wound checked for leakage. Diagnostic specimens were obtained in all cases. Five were found to be diffuse iris melanomas and 2 were indeterminate iris melanocytic proliferations. No patients developed a secondary increase in intraocular pressure, hyphema, infection, cataract, or vision loss. No cases of intraocular tumor dissemination were observed. No patient complained of glare or monocular diplopia. Three of 7 corneal wounds were self-sealing. Multifocal surgical iridectomy biopsy can be minimally invasive and effective allowing for partial- and full-thickness iris biopsy. Use of a 25-G aspiration cutting probe allowed for small incision surgery, rapid rehabilitation, and no significant complications.

  19. The effect of positioning devices and pressure therapy on outcome after full-thickness burns of the neck.

    PubMed

    Sharp, Patricia A; Dougherty, Mary E; Kagan, Richard J

    2007-01-01

    The postoperative management of full-thickness burns of the neck can be a challenge for burn therapists despite the availability of many treatment modalities to minimize scar hypertrophy and contracture. Interventions include pressure appliances, massage, exercise, and positioning devices. The objective of this study was to identify factors associated with the development of neck contractures and optimal treatment strategies for their prevention. We performed a retrospective chart review of all patients admitted to our pediatric burn center between 1989 and 2003 with acute full-thickness neck burns. Rehabilitation protocols used for each patient were examined. The necessity of a reconstructive procedure was analyzed, as well as time from initial grafting to that procedure. We identified 49 eligible subjects. Patients ranged in age from 0.6 to 14.2 years at the time of injury. The number of factors present which inhibited both positioning and application of pressure to the neck was found to be significantly related to the need for neck reconstruction (P < .01). Patients who had tracheostomies had a mean time to neck reconstruction of 20.3 months compared with 43.4 months in patients without tracheostomies (P < .05). Also, although not statistically significant, greater than 80% of patients who were discharged with reduced range of motion of the neck required reconstruction compared with fewer than 65% of patients with normal neck range. Delayed pressure and positioning of the neck after skin grafting result in an earlier and more frequent need for neck reconstruction.

  20. Perceived stress is associated with increased rostral middle frontal gyrus cortical thickness: a family-based and discordant-sibling investigation.

    PubMed

    Michalski, L J; Demers, C H; Baranger, D A A; Barch, D M; Harms, M P; Burgess, G C; Bogdan, R

    2017-11-01

    Elevated stress perception and depression commonly co-occur, suggesting that they share a common neurobiology. Cortical thickness of the rostral middle frontal gyrus (RMFG), a region critical for executive function, has been associated with depression- and stress-related phenotypes. Here, we examined whether RMFG cortical thickness is associated with these phenotypes in a large family-based community sample. RMFG cortical thickness was estimated using FreeSurfer among participants (n = 879) who completed the ongoing Human Connectome Project. Depression-related phenotypes (i.e. sadness, positive affect) and perceived stress were assessed via self-report. After accounting for sex, age, ethnicity, average whole-brain cortical thickness, twin status and familial structure, RMFG thickness was positively associated with perceived stress and sadness and negatively associated with positive affect at small effect sizes (accounting for 0.2-2.4% of variance; p-fdr: 0.0051-0.1900). Perceived stress was uniquely associated with RMFG thickness after accounting for depression-related phenotypes. Further, among siblings discordant for perceived stress, those reporting higher perceived stress had increased RMFG thickness (P = 4 × 10 -7 ). Lastly, RMFG thickness, perceived stress, depressive symptoms, and positive affect were all significantly heritable, with evidence of shared genetic and environmental contributions between self-report measures. Stress perception and depression share common genetic, environmental, and neural correlates. Variability in RMFG cortical thickness may play a role in stress-related depression, although effects may be small in magnitude. Prospective studies are required to examine whether variability in RMFG thickness may function as a risk factor for stress exposure and/or perception, and/or arises as a consequence of these phenotypes. © 2017 John Wiley & Sons Ltd and International Behavioural and Neural Genetics Society.

Top